Loading...
HomeMy WebLinkAboutHAZMAT 00-3081 - 1165 ANDOVER PARK WEST - GAS LEAK ON 9/13/20001165 ANDOVER PARK WEST GAS LEAK HAZMAT # 00-3081 1161 1177 xla Fare Department Page: 1 Incident Report 2000-0003081-000 00- 30V I Printed: 09/14/2000 16:09:57 Sunpro, Inc. FireRMS 5.0 Version: 2.0.25 Basic Alarm Date and Time Arrival Time Controlled Time Last Unit Cleared Time Response Time Priority Response Shift Incident Type Aid Given or Received Alarms Action Taken 1 Personnel - Suppression Personnel Property Loss Contents Loss Property Value Contents Value Property Use Location Type Address City, State Zip District Census Tract 00:54:00 Wednesday, Sept Mber 13, 2000 01:03:00 02:25:02 02:25:03 0:09:00 Yes B 412 - Gas leak (natural gas or LPG) N - None 1 40 - Hazardous condition, other 6 80.00 80.00 80.00 80.00 891- Warehouse Address 1165 ANDOVER PK W Tukwila, WA 98188 001 026200 Apparatus - E51 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Personnel Amount 1 Apparatus Personnel Amount 2 Apparatus Use Apparatus Action Taken 1 Apparatus Type E51 0:0900 • 00:54:00 Wednesday, September 13, 2000 00:54:00. Wednesday, September 13, 2000 01:03:00 Wednesday, September 13, 2000 08:00:03 Wednesday, September 13, 2000 Yea. 80.00 80.00 1 40 - Hazardous condition, other 11- Engine 04tr Apparatus - E52 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Personnel Amount 1 Apparatus Personnel Amount 2 Number of People Apparatus Use E52 0:09:00 01:54:00. Wednesday, September 13, 2000 00:54:00 Wednesday, September 13, 2000 01:03:00 Wednesday, September 13, 2000 08:00:03 Wednesday, September 13, 2000 Yes 80.00 80.00 6 1 Sunpro, Inc. FireRMS 5.0 Version: 2.0.25 Tukwila Fire Department Page: 2 Incident Report 2000-0003081-000 Printed: 09/14/2000 16:09:57 Sunpro, Inc. FireRMS 5.0 Version: 2.0.25 Apparatus - E52 Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 Personnel 3 Personnel 4 Personnel 5 Personnel 6 40 - Hazardous condition, other - --- 11- Engine Banastift, Robert Personnel ID: t142 Last Name: Bents First Name: Robert Number: 1142 Position::Ft Custxr, Kort' Personnel ID: 1171 Last Name: Custer First Name: Kir, Number: 1171 Poosition: FFI Ian,Brandon Personnel ID: 1174 Last Name: Kim First Name: Brandon Number. 1174 Position: FFIII Stevens, Jack Personnel ID: 1126 Last Name: Stevens First Name: Jack Number, 1126 Position: FFI Peterson, Lavern Personnel ID: 1122 Last Name: Peterson First Name: Lavern Number: 1122 Positieat: LT Lys, Wan PARD: 1i32 Last Nanto: Lucero Eir t Nance: Brian Number: 1132 Position: J1 : Authority . Reported By Officer In Charge Reviewer Robett "' _ :Robertilennatts Narrative Name Narrative Type Author Last Name Author First Name New N ve Incident Benn : ••. (ee",/,P,e4-Igt--- Robert Sunpro, Inc. FireRMS 5.0 Version: 2.0.25 Tukwila Fire Department Page: 3 inci ent teport 2000-0003081-000 Printed: 09/14/2000 16:09:57 Narratives Author Rank FFI Author Assignment 1 Narrative Date 16:00:45 Thursday, September 14, 2000 Narrative Text At 0054 hours on Wednesday September 13, 2000 we were dispatched to a gas leak. Two units were assigned to this incident. Six personnel responded. We arrived on scene at 0103 hours and cleared at 0800 hours. The incident occurred at 1165 ANDOVER PK W, Tukwila in District 001. The general description of this property is warehouse. No mutual/automatic aid was given or received. Alarm number 0003081 has been assigned to this incident. A full commercial response was dispatched but L54 and A54 was turned around in route since the incident was easily controlled by turning off the Gas supply and ventilating the building. The leak was caused by a forklift accident with a ceiling heating unit, breaking the supply line. Occupancy management was notified so they could repair the problem promptly. Puget Sound Energy was called in to check on the Gas meter and lock it out. and also read the level of gas in the warehouse. E51 cleared after the level was well below the hazard point. End of Report Sunpro, Inc. FireRMS 5.0 Version: 2.0.25 ' � ~- ��~� � � ��~~ ` Incident History tor: #TF00002945 CN: $TF00003081 Received 09/13/00 00:54:23 BY CRO8 /MCAVAN Entered 09/13/00 00:55:J3 BY CR88 /MCAVAN Dispatched 09/13/00 00:56:10 BY FD21 /SANTIN Enroute 09/13/00 00:59:05 Onscene 09/13/00 01:03:23 Closed 09/13/00 02:25:52 Initial Type: NGAGIN Initial Alarm Level: 1 Final Type: NGASIN (NATURAL GAS LEAK INSIDE (2A)) Pri: 1 Disoo: Police TP1200 Fire TF5134 Group: T9 Beat: Police Rms: Fire Rms: Medic Rms: Loc: 1165 ANDOVER PARK W ST .TUK near UNK Name: HAL%DAY,KERRY/EMPLY Addr: ALLIED INTERNATIONAL EX Phone: 2065751426 Alrm L /0055 MCAVAN CR0B ENTRY /0056 SANTIN FD21 DISP E51 /0056 /uA56 /0056 /0056 /0059 /0059 /0059 /01U0 /0103 /0104 /0104 /0104 /U1U4 /d104 /0114 /0115 /U116 /0125 /U126 /0134 /O147 /0225 TF7071 SANTIN TF9526 SANTIN TF7071 SANTIN FD21 FD21 E52 FD21 L54 FD21 FD21 FD21 FD21 FD21 FD21 FD21 FD21 FD21 FD21 FD21 FD21 FD21 E52 FD21 NATURAL GAS LEAKING FROM HEATER IN ROOF... RP RIPPED PIPE OFF..IS EVACUATING STF00003081 #TF6037 #TF6U3A #TF0001 #TF5174 ASST E52 #TF7071 #TF3859 #TF0002 #TF9524 ASST A54 #7F8223 #TF1165 ASST L54 #TF9526 #TF7879 #TF0004 #TF3402 ASST TFlNFU #TFINFO #TFINV *ENROUT ENROUT *ENROUT ENROUT ONBCNE MISC ONSCNE CLEAR CLEAR CLEAR MISC MISC MISC MISC OLIS MISC MOBlN5 CLEAR E52 A54 L54 E51 E51 E51 E52 TFINFO A54 L54 E51 E51 E51 E51 E52 E51 E52 E51 /0225 FD2i CLOSE E51 BENNATTS. ROB KIM. BRANDON TUKWILA FIRE RADIO CUSTER. KORY NAEL" CHUCK LUCERO. BRIAN TUKWILA FIRE RADIO STEVENS. JACK - P561 POMEROY. BARRr E MCCOY. PAT GRISHAM, MARTY WOOLLEY. CHUCK TUKWILA FIRE RADIO BECKMAN. KEN TUKWILA CHIEF INFO PAGER TUKWILA INSPECTOR PAGER .LG WAREHOUSE COMPLEX OCC OUTSIDE INV .CODE GREEN ALL INCOMING ACC FOR E52 .LEAK IN LINE 10 HEATER NEED GAS CO .1-800- 552-7171 "GAS CO NOTIFIED .ETA ON GAS CO AND VENTILATING THE BLDG .LESS THEN 10 MIN ON GAS .GAS CO FOUND BLDG NO HAZARD CARE OF WAREH OUSE MAN