Loading...
HomeMy WebLinkAboutHAZMAT 00-3685 - 14415 TUKWILA INTERNATIONAL BLVD - GAS LEAK ON 11/1/200014415 TUKWILA INTERNATIONAL BLVD GAS LEAK HAZMAT # 00-3685 Firs Department , Page: 1 Incident Report 2000-0003685-000 Jk00-3C0 `is Printed: 11/01/2000 22:15:40 Basic Alarm Date and Time 13:44:00 Wednesday, November 1, 2000 Arrival Time 13:49:00 Controlled Time 14:36:00 Last Unit Cleared Time 14:36:01 Response Time 0:05:00 Priority Response Yes Fire Department Station ST54 Shift A Incident Type 412 - Gas leak (natural gas or LPG) Aid Given or Received 2 - Automatic aid received Mutual Aid Department STFD Alarms 1 Action Taken 1 92 - Standby Action Taken 2 82 - Notify other agencies. Personnel - Suppression Personnel 3 Property Loss $0.00 Contents Loss $0.00 Property Value $0.00 Contents Value $0.00 Property Use 571- Service station, gas station Location Type Address Address 14415 Tukwila Intl BL City, State Zip Tukwila, WA 98168 District 13 Census Tract 262 . Apparatus - L54 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Personnel Amount 1 Apparatus Personnel Amount 2 Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Action Taken 2 Apparatus Type Personnel 1 Personnel 2 Sunpro, Inc. FireRMS 5.0 Version: 2.0.25 L54 0:05:00 13:44:00 Wednesday, November 1, 2000 13:44:00 Wednesday, November 1, 2000 13:49:00 Wednesday, November 1, 2000 14:36:01 Wednesday, November 1, 2000 Yes $0.00 $0.00 3 1 92 - Standby 82 - Notify other agencies. 13 -Quint Lucero, Brian Personnel ID: 1132 Last Name: Lucero First Name: Brian Number: 1132 Position: FFI Roberts, Martin Personnel ID: 1138 ' Tukwila Fire Department Page: 2 Incident Report 2000-0003685-000 Printed: 11/01/2000 22:15:40 umt was assigned to thrs incident. Three personnel responded. We arrived on scene at 1349 hours and cleared at 1436 hours. The incident occurred at 14415 Tukwila Intl Bl, Tukwila in District 13. The local station is ST54. The general description of this property is service station, gas station. The primary task(s) performed at the scene by responding personnel was standby. Automatic aid was received on this incident. Alarm number 0003685 has been assigned to this incident. Propane tank approx 500 gals was filled in the a.m., witnesses report a release of gas from the relief valve. Inspected tank, found some liquid on tank below relief valve. Checked gauge, showed 80% full, which is considered full. Called for Suburban Propane to send a rep to investigate. Upon arrival, rep determined gauge was improperly installed, and actual tank level was 100%. He called for a propane delivery truck to remove excess propane. L54 stood by until transfer was completed. End of Report Sunpro, Inc. FireRMS 5.0 Version: 2.0.25 Apparatus - L54 Personnel 3 Last Name: Roberts First Name: Martin Number: 1138 Position: FFI Ewing, David Personnel ID: 1108 Last Name: Ewing First Name: David Number: 1108 Position: LT Authority Reported By Officer In Charge Reviewer David Ewing David Ewing Narratives Narrative Name Narrative Type Author Last Name Author First Name Author Rank Author Assignment Narrative Date Narrative Text New Narrative Incident Ewing David LT 1 22:11:02 Wednesday, November 1, 2000 At 1344 hours on Wednesday November 1, 2000 we were dispatched to a gas leak. One • umt was assigned to thrs incident. Three personnel responded. We arrived on scene at 1349 hours and cleared at 1436 hours. The incident occurred at 14415 Tukwila Intl Bl, Tukwila in District 13. The local station is ST54. The general description of this property is service station, gas station. The primary task(s) performed at the scene by responding personnel was standby. Automatic aid was received on this incident. Alarm number 0003685 has been assigned to this incident. Propane tank approx 500 gals was filled in the a.m., witnesses report a release of gas from the relief valve. Inspected tank, found some liquid on tank below relief valve. Checked gauge, showed 80% full, which is considered full. Called for Suburban Propane to send a rep to investigate. Upon arrival, rep determined gauge was improperly installed, and actual tank level was 100%. He called for a propane delivery truck to remove excess propane. L54 stood by until transfer was completed. End of Report Sunpro, Inc. FireRMS 5.0 Version: 2.0.25 Incident History for: #TF.00003524 CN: $TF00003685 Received li/01/00 13:43:39 BY CRO4 /RETTIG Entered Dispatched Enroute Onscene Closed 11/01/00 13:44:19 BY CRO4 /RETTIG 11/01/00 13:44:49 BY FD21 /MATSON 11/01/00 13:46:32 11/01/00 13:49:06 11/01/00 14:36:55 s00 -a015 Initial Tvpe: ODORXT Initial Alarm Level: 1 Final Type: NOASXT (NATURAL GAS LEAK OUTSIDE (5A)) Pri: 1 Dispo: Lev: 1 Police TP2700 Fire TF542o Group: X8 Beat: Police Rms: Fire Rms: — Medic Rms: Loc: 14415 TUKWILA INTERNATIO BL .TUK near UNK Name: SINGH. PR1T0M/EMNLr Addr: SEVENTY SIX /1344 RETTIG CRO4 /1344 CRO4 /1344 4ATSON FD21 /1344 FD2i / 1344 /1344 FD21 FD21 /1344 FD21 /1344 FD21 /1345 BLOOMI FD22 /1345 RETTIG CRO4 /1345 /1346 /1347 /1348 /1349 /1349 /1350 /1350 /1351 /.1351 / 1411 ENTRY $ASNCAS BALNCE DISP L54 ASST E47 ASST A54 ASST ASNCAS CLEAR SUPP BLOOMI FD22 CONTRL TF8163 MATSON BLOOMI Alrm Phone: 244-1622 POSS PROPANE TANK LEAK $TF00003665 Type changed to T/NGASXT #TF8163 EWING. DAVE #TF2301 MCCONE. DAN J" #TF0004 TUKWILA FIRE RADIO #TF3859 LUCERO. BRIAN #IF0001 SEA -TAC FIRE #TF1165 MCCOY. PAT #TF5504 ROBERTS. MARTY F2 F2 $XF00005799 F2 L54 *ENROUT L54 FD21 ENROUT A54 FD22 ENROUT E47 FD22 ONSCNE L54 FD22 ONSCNE A54 FD22 ONSCNE E47 Fli22 MISC L54 FD22 MOBINS A54 Fli22 MOBINS E47 Fli22 MISC L54 /1436 TF8163 L54 /1436 L54 MOBINS L54 CLOSE L54 NAM: SINGH. PRITOM/EMPLY PHO: 2062441622 TXT: *LANGUAGE BARRIER* PROPANE TANK IS OU TSIDE OF BLDG ON WEST SIDE. GRP: T9 ---'> X8. . NV . MINOR LEAK . SUBURBAN PROPANE HAS ARRIVED AND. TANK IS OVERFILLED