Loading...
HomeMy WebLinkAboutHAZMAT 01-1670 - 4635 S 148TH ST - GAS LEAK ON 5/20/20014635 S 148TH ST GAS LEAK HAZMAT # 01-1670 ""f'ukwiiaJe Department Pagdr`1 Incident Report 2001-0001670.000 401 —110.70 Fruited: 05/20/2001 14:33:05 Alarm Date and Time Arrival Time Controlled Time Last Unit Cleared Time Response Time Priority Response Fire Department Station Shift Incident Type Aid Given or Received Alarms Action Taken 1 Apparatus - Suppression Personnel - Suppression Personnel Property Loss Contents Loss Property Value Contents Value Property Use Location Type Address City, State Zip District Census Tract Basic 12:49:00 Sunday, May 20, 2001 12:54:00 13:04:00 13:23:00 0:05:00 Yes ST54 A 412 - Gas leak (natural gas or LPG) N - None 1 45 - Remove hazard 2 4 $0.00 S0.00 $0.00 $0.00 419 -1 or 2 family dwelling Address 4635 S 148 ST Tukwila, WA 98168 11 262 . Apparatus - L54 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Personnel Amount 1 Apparatus Personnel Amount 2 Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 Sunpro, Mc. FireRMS 5.0 Version: 2.0.25 L54 0:05:00 12:49:00 Sunday, May 20, 2001 12:49:00 Sunday, May 20, 2001 12:54:00 Sunday, May 20, 2001 13:23:00 Sunday, May 20, 2001 Yes 80.00 80.00 4 1 45 - Remove hazard 13 -Quint Ewing, David Personnel ID: 1108 Last Name: Ewing First Name: David Number: 1108 Position: LT McCone, Daniel Personnel ID: 1133 Last Name: McCone First Name: Daniel 1`ukwda Fide Department Pager -2 Incident Report 2001-0001670.000 Printed: 05/20/2001 14:33:05 Apparatus - L54 Personnel 3 Personnel 4 Number: 1133 Position: FFII Roberts, Martin Personnel ID: 1138 Last Name: Roberts First Name: Martin Number 1138 Position: FFI Rookstool, Edward Personnel ID: 1183 Last Name: Rookstool First Name: Edward Number: 1183 Position: FFP Apparatus - A54 Apparatus ID A54 Response Time 0:05:00 Apparatus Dispatch Date and Time 12:49:00 Sunday, May 20, 2001 En route to scene date and time 12:49:00 Sunday, May 20, 2001 Apparatus Arrival Date and Time 12:54:00 Sunday, May 20, 2001 Apparatus Clear Date and Time 13:23:00 Sunday, May 20, 2001 Apparatus priority response Yes Apparatus Personnel Amount 1 S0.00 Apparatus Personnel Amount 2 $0.00 Number of People 2 Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 1 45 - Remove hazard 75 - BLS unit McCoy, Patrick Personnel ID: 1153 Last Name: McCoy First Name: Patrick Number. 1153 Position: FFI Willis, Brian Personnel ID: 1179 Last Name: Willis First Name: Brian Number: 1179 Position: FFII Reported By Officer In Charge Reviewer David Nang David Ewing Authority Narratives Narrative Name Sunpro, Inc. FireRMS 5.0 Version: 2.0.25 New Narrative Pte Department Page: 3 Incident Report 2001-0001670-000 Printed: 05/20/2001 14:33:05 Narratives Narrative Type Incident Author Last Name Ewing Author First Name David Author Rank LT Author Assignment 1 Narrative Date 14:27:17 Sunday, May 20, 2001 Narrative Text At 1249 hours on Sunday May 20, 2001 we were dispatched to a gas leak. Two units were assigned to this incident. Six personnel responded. We arrived on scene at 1254 hours and cleared at 1323 hours. The incident occurred at 4635 S 148 St, Tukwila in District 11. The local station is ST54. The general description of this property is 1 or 2 family dwelling. The primary task(s) performed at the scene by responding personnel was hazard removal. No mutual/automatic aid was given or received. Alarm number 0001670 has been assigned to this incident. Five gallon propane tank was venting though the relief valve. Found tank in full sun in front yard, relief valve sputtering out liquid propane. Resident says tank was just filled. Took tank to a remote spot in open air and bled off tank to what felt approxomately the correct weight. Liquid propane initially bled out of bunk. Advised resident that tank had been overfilled, to keep it out of direct sun, and use the tank as soon as possible to lower the level further. Also advised them not to store it inside a structure or in a location where the vapors could collect in a low spot. End of Report Sunpro, Inc. FireRMS 5.0 Version: 2.0.25 7, ISTIcTO incident Received Entered Dispatched Enroute Onscene Closed History for: #TF01001603 05/20/01 12:48:02 BY PD32 05/20/01 12:48:49 BY PD32 05/20/01 12:49:U2 BY FD21 05/20/01 12:50:58 05/20/01 12:54:39 05/20/01 13:23:59 61- t(orjo CN: STF01001670 /VCO262 /VCO262 /VC1OG2 Initial Type: HZLEAK Initial Alarm Level: 1 Final Type: HZLEAK (HAZD CHEMICAL SPILL LEAK (2A)) Police TP2500 Fire TF5421 Group: T9 Beat: Police Rms: Fire Rms: Medic Rms: Loc: 4635 S 148 ST .TUK near UNI. Name: MITZEL, ANN Addr: Contact: Y /1248 /1248 /1249 /1249 /1249 VCO262 PD32 PD32 VC1082 FD21 ENTRY $ASNCAS DISP L54 FD21 ASST A54 FD21 ASST TFINFO /1250 FD21 CLEAR TFINFO /1250 TF8163 L54 *ENROUT L54 /1252 VC1082 FD21 ENROUT A54 /1254 FD21 ONSCNE A54 /1255 FD21 ONSCNE L54 /1256 FD21 MOBINS A54 /1304 FD21 OLIS L54 /1323 TF8163 L54 MOBINS L54 /1323 L54 CLOSE L54 Pri: 2 Dispo: Alrm Phone: 2062446484 **LEAKING PROPANE TANK*** STF01001670 *TF8163 EWING, DAVE #TF5504 ROBERTS, MARTY #TF7866 ROOKSTOOL, EDWARD #TF2301 MCCUNE, DAN J #TF1165 MCCOY, PAT #TF9874 WILLIS. BRIAN #TFINFO TUKWILA CHIEF INFO PAGER #TF4910 TOMASO, DON