Loading...
HomeMy WebLinkAboutHAZMAT 04-1710 - 6810 S 180TH ST - GAS LEAK ON 5/29/20046810 S 180TH ST GAS LEAK HAZMAT # 04-1710 Incident Report 2004-0001710-000 Tukwila Fire Department Vr0 Basic Alarm Date and Time Arrival Time Controlled Time Last Unit Cleared Time Response Time Priority Response Fire Department Station Shift Incident Type Aid Given or Received Mutual Aid Department Alarms Action Taken 1 Action Taken 2 Apparatus - Suppression Personnel - Suppression Personnel Property Loss Contents Loss Property Value Contents Value Hazardous Material Released Property Use Location Type Address City, State Zip District Census Tract 08:12:00 Saturday, May 29, 2004 08:17:00 08:26:00 08:59:00 0:04:60 Yes 51 A 412 - Gas leak (natural gas or LPG) 2 - Automatic aid received 17M14 1 64 - Shut down system 42 - HazMat detection, monitoring, sampling, & analysis 3, 7 $0.00 $0.00 $0.00 $0.00 1- Natural gas - slow leak, no evacuation or hazmat actions 559 - Recreational, hobby, home repair sales, pet store Address 6810 S 180 ST Tukwila, WA 98188 006 0262.00 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 Personnel 3 E51 0:04:60 08:12:00 08:12:00 08:17:00 08:59:00 Yes 3 1 86 - Investigate 11 - Engine 1117 - Lyons, Philip Position: LT Personnel Action Taken 1: 86 - Investigate 1168 - Hickey, Matt Position: FFI 1142 - Bennatts, Robert Position: FFI Apparatus - E51 Saturday, May 29, 2004 Saturday, May 29, 2004 Saturday, May 29, 2004 Saturday, May 29, 2004 Page: 1 Printed: 05/30/2004 07:30:51 Incident Report 2004-0001710-000 Tukwila Fire Department Apparatus - E52 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 Personnel 3 E52 0:04:60 08:12:00 08:12:00 08:17:00 08:59:00 Yes 3 1 64 - Shut down system 11- Engine 1119 - McFarland, Loren Position: LT Personnel Action Taken 1: 64 - Shut down system 1163 - Rydeen, Steven Position: FFI 1123 - Gilbert, Matt Position: FFIII Saturday, May 29, 2004 Saturday, May 29, 2004 Saturday, May 29, 2004 Saturday, May 29, 2004 Apparatus - B51 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 B51 0:04:60 08:12:00 Saturday, May 29, 2004 08:12:00 Saturday, May 29, 2004 08:17:00 Saturday, May 29, 2004 08:59:00 Saturday, May 29, 2004 Yes 1 1 81- Incident command 92 - Chief officer car 1112 - Grisham, Martin Position: CAPT Personnel Action Taken 1: 92 - Standby Authority Reported By Officer In Charge Reviewer 1117 - Lyons, Philip 09:35:37 Saturday, May 29, 2004 1117 - Lyons, Philip 09:35:38 Saturday, May 29, 2004 lz Narratives Narrative Name Narrative Type Narrative Date Author New Narrative Incident 09:35:40 Saturday, May 29, 2004 1117 - Lyons, Philip Page: 2 Printed: 05/30/2004 07:30:51 1 • Incident Report 2004-0001710-000 Tukwila Fire Department Narratives Author Rank Author Assignment Narrative Text LT 1 At 0812 hours on Saturday May 29, 2004 we were dispatched to a gas leak. Three units were assigned to this incident. Seven personnel responded. We arrived on scene at 0817 hours and cleared at 0859 hours. The incident occurred at 6810 S 180 St, Tukwila in District 006. The local station is 51. The general description of this property is recreational, hobby, home repair sales, pet store. The primary task(s) performed at the scene by responding personnel was to shut down system. Automatic aid was received on this incident. Alarm number 0001710 has been assigned to this incident. Dispatched to Smell of nat gas. R/P was customer no longer on location. Manager stated that fork lift had damaged gas supply to heater. Shut off and locked out gas meter. Took concentration readings at floor and cieling levels with results of < 1 ppm. Evacuation not necessary. WNG notified. Repair contractor notified by store personnel. Note: Asst manager on duty at time of incident did not call 9-1-1. He notified Corporate headquarters in Atlanta, Ga. who told him they would put all "systems on hold" and call for local repair contractor. Stressed with both managers the need to report any emergent situation to the fire department. Manager stated this was a "wake up call " and that he would establish emergency procedures with his new managers. Offered assistance in formulating store policy related to emergency procedures. Store manager: Doug Remem 206-575-9200 Asst manager: Sean Simmons Corporate H/Q : 1-770-384-5163 Atlanta, Ga. End of Report Page: 3 Printed: 05/30/2004 07:30:51 Incident Ret a i~sed Entered Dispatched Enroute Onscene Closed History for:#TF04001632 CN: $TF04001710 Initial Final Lev: 1 Police Police 05/29/04 05/29/04 05/29/04 05/29/04 05/29/04 05/29/04 08:12:03 BY CR07 /VC6719 08:12:45 BY CR07 /VC6719 08:13:14 BY FD23 /VC1140 08:15:04 08:17:09 08:58:19 D4/1770 Type:NGASIN TG: Initial Alarm Level:1 Type:NGASXT (NATURAL GAS LEAK OUTSIDE (5A))Pri:lDispo: TP1200 Rms: Fire TF5135 Grp:T7Beat: Lt/Lg: Fire Rms: Medic Rms: Loc:6810 S 180 ST ,TUK -- HOME DEPOT (V) Name:MALE/911 Addr:NP HOME DEPOT 08:12:45 VC6719 CR07 ENTRY 08:12:45 CR07 $ASNCAS 08:13:09 VC1140 FD23 CHANGE 08:13:14 08:13:14 08:13:14 FD23 FD23 FD23 08:13:14 FD23 08:13:31 VC6719 CR07 08:13:59 VC1140 FD23 08:15:04 08:15:24 08:15:45 08:17:09 08:17:37 08:17:40 08:17:47 08:19:08 VC1451 VC1140 DISP ASST ASST Alrm Phone:2065759432 RP IS CUSTOMER, STRONG SMELL GAS INS LOC N, RP UNSURE IF EMPL ARE AWARE OF SMELL, RP LEAVING LOCN $TF04001710 TYP: NGASIN ---> NGASXT. E51 #TF3637 SCHELL, JIM #TF7485 LINDSEY, JAMES E #TF3196 HICKEY, MATT C/F3 E52 #TF2016 #TF1436 #TF3439 C/F3 A14 #RF0105 #RF0114 #RF0172 C/F3 $RF04003776 NAM: MALE/911 TXT: RP CALLING FROM $FONE OUTSIDE NEAR ENTRANCE, THINKS MAY HAVE COME FROM A HE ATER THAT WAS OVERTURNED, BUT UNSURE, RP REFUSED TO GIVE PERSONAL INFO GRP: T9 ---> T7. ASNCAS A14 SUPP CONTRL FD22 ENROUT A14 FD22 ENROUT E51 FD23 ENROUT E52 FD23 ONSCNE E51 FD23 MISC FD23 ASSTOS B51 FD23 MISC FD23 MISC MCFARLAND, LOREN GILBERT, MATTHEW RYDEEN, STEVE WELCH, LARRY CURTIS, TOM SEDLACEK, SHANNON , ALL YELLOW [6810 S 180 ST ,TUK] #TF1407 FEHR, TED , DOING A 360 ,NOTHING AT THE METER 08:20:15 VC6674 FD24 MISC E51 , MGR ON WAY OUYT &8,20't5.0 FD24 MOBINS A14 ,CG 08:24:10 TF2016 E52 *ONSCNE E52 08:26:15 VC6674 FD24 MISC B51 , DAMAGED GAS LINE INSIDE, E51 DOING SOM E AIR MONITORING , E52, TO SIDE B TO MAK E SURE METER IS SHUT OFF 08:31:05 FD24 MISC B51 , GAS IS SHUT OFF 08:41:48 FD24 CLEAR E52 08:43:58 FD24 CLEAR B51 08:58:19 FD24 MOBINS E51 08:58:19 FD24 CLOSE E51