Loading...
HomeMy WebLinkAboutHAZMAT 04-1818 - 17025 SOUTHCENTER PKWY - GAS LEAK ON 6/8/200417025 SOUTHCENTER PKWY GAS LEAK HAZMAT # 04-1818 Incident Report 2004-0001818-000 Tukwila Fire Department Basic Alarm Date and Time Arrival Time Controlled Time Last Unit Cleared Time Response Time Priority Response Completed Fire Department Station Shift Incident Type Aid Given or Received Mutual Aid Department Alarms Action Taken 1 Apparatus - Suppression Aid Apparatus - Suppression Personnel - Suppression Personnel Property Loss Contents Loss Property Value Contents Value Property Use Location Type Address City, State Zip District Census Tract 09:48:43 Tuesday, June 8, 2004 09:54:13 10:52:03 10:52:04 0:05:30 Yes Yes 51 C 412 - Gas leak (natural gas or LPG) 2 - Automatic aid received 17M08 1 45 - Remove hazard 4 2 11 $0.00 $0.00 $0.00 $0.00 160 - Eating, drinking places Address 17025 Southcenter PKY Tukwila, WA 98188 007 0262.00 Apparatus - E51 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Personnel Amount 1 Apparatus Personnel Amount 2 Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 E51 0:05:30 09:48:43 09:48:43 09:54:13 10:52:04 Yes $0.00 $0.00 3 1 45 - Remove hazard 11 - Engine 1184 - Hansen, Greg Position: FFIII Amount 1- $0.00 Amount 2: $0.00 1129 - Wheeler, Stephen Position: LT Tuesday, June 8, 2004 Tuesday, June 8, 2004 Tuesday, June 8, 2004 Tuesday, June 8, 2004 Page: 1 Printed: 06/08/2004 17:40:58 Incident Report 2004.0001818-000 Tukwila Fire Department Apparatus - E51 Personnel 3 Amount 1: $0.00 Amount 2: $0.00 1185 - Whitcutt, Roy S Position: FFIII Amount 1: $0.00 Amount 2: $0.00 Apparatus - B51 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Personnel Amount 1 Apparatus Personnel Anwunt 2 Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 B51 0:05:30 09:48:43 09:48:43 09:54:13 10:52:04 Yes $0.00 $0.00 1 1 45 - Remove hazard 92 - Chief officer car 1122 - Peterson, Lavern Position: LT Amount 1: $0.00 Amount 2: $0.00 Tuesday, June 8, 2004 Tuesday, June 8, 2004 Tuesday, June 8, 2004 Tuesday, June 8, 2004 Apparatus - E52 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Personnel Amount 1 Apparatus Personnel Amount 2 Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 E52 0:05:30 09:48:43 Tuesday, June 8, 2004 09:48:43 Tuesday, June 8, 2004 09:54:13 Tuesday, June 8, 2004 10:52:04 Tuesday, June 8, 2004 Yes $0.00 $0.00 3 1 45 - Remove hazard 11- Engine 1181- Popejoy, Toby Position: FFII Amount 1: $0.00 Amount 2: $0.00 1137 - Reed, Ken Position: LT Amount 1: $0.00 Amount 2: $0.00 Page: 2 Printed: 06/08/2004 17:40:58 Incident Report 2004-0001818-000 Tukwila Fire Department Page: 3 Printed: 06/08/2004 17:40:58 Apparatus - E52 Personnel 3 1174 - Kim, Brandon Position: FFI Amount 1: $0.00 Amount 2: $0.00 Apparatus - E54 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Personnel Amount 1 Apparatus Personnel Amount 2 Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 Personnel 3 Personnel 4 E54 0:05:30 09:48:43 Tuesday, June 8, 2004 09:48:43 Tuesday, June 8, 2004 09:54:13 Tuesday, June 8, 2004 10:52:04 Tuesday, June 8, 2004 Yes $0.00 $0.00 4 1 45 - Remove hazard 11- Engine 1165 - Brooks, James Position: FFI Personnel Action Taken 1: 45 - Remove hazard Personnel Action Taken 2: 42 - Hazmat detection, monitoring, sampling, & analysis Personnel Action Taken 3: 51- Ventilate Amount 1: $0.00 Amount 2: $0.00 1158 - Brooks, Merle Position: FFI Amount 1: $0.00 Amount 2: $0.00 1131- Wojcik, Peter Position: LT Amount 1: $0.00 Amount 2: $0.00 1114 - Konieczka, Jason Position: FFI Amount 1: $0.00 Amount 2: $0.00 Authority Reported By Officer In Charge Reviewer 1129 -Wheeler, Stephen �� 17:17:20 Tuesday, June 8, 2004 A(l_ ) 1129 - Wheeler, Stephen W 17:17:22 Tuesday, June 8, 2004 / - , Narratives Page: 3 Printed: 06/08/2004 17:40:58 Incident Report 2004-0001818-000 Tukwila Fire Department Narratives Narrative Name Narrative Type Narrative Date Author Author Rank Author Assignment Narrative Text New Narrative Incident 17:23:40 Tuesday, June 8, 2004 1129 - Wheeler, Stephen LT 1 At 0948 hours on Tuesday June 8, 2004 we were dispatched to a gas leak. Four units were assigned to this incident. Eleven personnel responded. We arrived on scene at 0954 hours and cleared at 1052 hours. The incident occurred at 17025 Southcenter Pky, Tukwila in District 007. The local station is 51. The general description of this property is eating, drinking places. The primary task(s) performed at the scene by responding personnel was hazard removal. Automatic aid was received on this incident. Alarm number 0001818 has been assigned to this incident. E51,52,54, A74,1351 were dispatched to a reported gas leak at 17025 Southcenter Pkwy. B51 arrived first and requested E51 pull into the East end of the parking lot. B51 did a face to face with E51 and we were to enter the building in full SCBA,s. We were instructed to monitor the air inside the building. Lt. Wheeler and FF Whitcutt entered the business at 17025 Southcenter Parkway. The monitor showed 20o2 and no lel,s. E51 withdrew from this address and reported this to B51. We concluded that we should check the adjoining buissness. E52 entered the flower Drum restaurant and found that this was full of gas odor. There monitor showed 1 on lel. They also determined that the leak was coming from this business. E52 shut off the gas appliances in the Flower Drum Restaurant. E51 set up a ppv fan at 17025 and E52 set up a fan at the Flower Drum Restaurant. E51 shut off the gas meter in the rear of the restaurant and locked it out. B51 called for PSE and E51 monitored the atmosphere in both business locations. E51 found elevated co levels from the ppv operations. The fans were shut down and the atmosphere was rechecked. All readings were normaL E51 cleared the call after monitor showed normal lel,s and normal co and o2. End of Report Page: 4 Printed: 06/08/2004 17:40:58 Incident History for:#TF04001735 tetei.v d 06/08/04 09:48:16 Entered 06/08/04 09:48:43 Dispatched 06/08/04 09:48:49 Enroute 06/08/04 09:50:38 Onscene 06/08/04 09:54:13 Closed 06/08/04 10:52:03 CN: $TF04001818 BY CR10 /VC1554 BY CR10 /VC1554 BY FD23 /VC5585 A6- ow, —1 1g Initial Type:NGASIN TG: Initial Alarm Level:1 Final Type:NGASIN (NATURAL GAS LEAK INSIDE (2A))Pri:lDispo: ev: 1 Police TP900 Fire TF5131 Grp:T7Beat: Lt/Lg: Police Rms: Fire Rms: Medic Rms: Loc:17025 SOUTHCENTER PY ,TUK -- FUTON 123 (V) Name:ANGELA - MGR Addr:FUTON 123 09:48:43 VC1554 CR10 09:48:43 CR10 09:48:49 VC5585 FD23 09:48:49 Alrm L Phone:2065759709 ENTRY SMELL OF NATURAL GAS. $ASNCAS $TF04001818 DISP E51 #TF4256 WHEELER, STEVE #TF363A WHITCUTT, ROY #TF9391 HANSEN, GREG C/F3 FD23 ASST E52 #TF9701 REED, KEN #TF603A KIM, BRANDON #TF4756 POPEJOY, TOBY C/F3 #TF2769 WOJCIK, PETE #TF9497 BROOKS, MERLE #TF0577 KONIECZKA, JASON #TF5221 BROOKS, JIM C/F3 #KF0055 ROBBINS, JOHN #KF0089 THOMPSON, DAN C/F3 $KF04005822 #KF0057 READ, GARY #KF0081 SMALE, MARTIN #KF0048 YOUNG, DENNIS C/F3 #TF9526 GRISHAM, MARTY C/F3 NAM: ANGELA - MGR TXT: SMELL IS INSIDE (DID NOT NOTICE ANY THING OUTSIDE). GRP: T9 ---> T7. 09:48:49 FD23 ASST E54 09:48:49 FD23 ASST A74 09:48:49 FD23 ASNCAS A74 09:48:49 FD23 ASST L74 09:48:49 FD23 ASST B51 09:48:16? VC1554 CR10 SUPP 09:49:41 VC5585 FD23 CONTRL 09:50:38 09:50:38 09:50:58 09:50:59 VC7999 FD24 KF0057 L74 VC7999 FD24 KF0055 A74 ENROUT B51 *ENROUT L74 ENROUT E52 *ENROUT A74 ,FROM 54 09:51:06 TF2769 E54 *ENROUT E54 1)n51(:49 VC5585 FD23 ENROUT E51 09:54:13 VC7999 FD24 ONSCNE B51 ,NORTH END OF 150 45 2 ST COM COMP, INV, E51 TO P/L 09:54:16 FD24 ONSCNE E51 [P/L] 09:54:24 FD24 NEWLOC B51 [NORTH END] 09:55:16 VC6730 FD22 MISC B51 , STRONG ODOR OF NAT GAS IN BLDG, E51 IN V, B51 PARKWAY COMMAND - AT MY VEH 09:55:27 FD22 MISC E52 , PARK ON E END OF P/L 09:55:32 VC7999 FD24 ONSCNE E52 [STNDBY] 09:55:35 VC6730 FD22 NEWLOC B51 [PARKWAY COMMAND] 09:56:13 VC7999 FD24 MISC B51 ,STRONG SMELL OF GAS INS BLDG 09:56:25 FD24 NEWLOC B51 [CMD/VEH] 09:56:33 FD24 ONSCNE E54 09:57:05 FD24 CLEAR L74 09:57:18 FD24 CLEAR A74 10:11:53 FD24 MISC B51 ,GAS LEAK IS FROM 17005, COOKING APPLIAN CE 10:14:02 FD24 OLIS E54 10:20:04 FD24 NEWLOC B51 [PRKWY CMD] 10:26:27 FD24 CLEAR B51 10:26:31 FD24 CLEAR E54 10:26:42 FD24 CLEAR E52 10:42:43 FD24 MISC E51 ,PSE ADV'D 5 AGO 10:52:03 FD24 CLEAR E51 10:52:03 FD24 CLOSE E51