Loading...
HomeMy WebLinkAboutHAZMAT 05-1204 - 12720 GATEWAY DR - GAS LEAK ON 4/15/200512720 GATEWAY DR GAS LEAK HAZMAT # 05-1204 Incident Report 2005-0501204-000 Tukwila Fire DepartmentI I v v Page: 1 Printed: 04/16/2005 00:43:37 Basic Alarm Date and Time Arrival Time Controlled Date and Time Last Unit Cleared Date and Time Response Time Priority Response Completed Fire Department Station Shift Incident Type Aid Given or Received Mutual Aid Department Alarms Action Taken 1 Action Taken 2 Apparatus - Suppression Apparatus - Other Personnel - Suppression Personnel Personnel - Other Property Loss Contents Loss Property Value Contents Value Hazardous Material Released Property Use Location Type Address City, State Zip District Census Tract Directions 20:30:08 Friday, April 15, 2005 20:35:26 21:37:23 Friday, April 15, 2005 0:05:18 Yes Yes 53 B 412 - Gas leak (natural gas or LPG) 2 - Automatic aid received 17D11 1 86 - Investigate 45 - Remove hazard 3 1 7 1 $0.00 $0.00 $0.00 $0.00 0 - Special hazmat actions required or spill greater than 55 gallons 241- Adult education center, college classroom Address 12720 GATEWAY DR Tukwila, WA 98168 001 0272.00 12720 GATEWAY DR ,TUK Person Involved - STUDENT, Involvement Code Last Name Street Address City, State Zip REP STUDENT 12720 GATEWAY DR Tukwila, WA 98168 Hazmat Story of Release Outside of Structure Population Density Area Affected Area Affected Unites Area Evacuated Area Evacuated Units Estimated Number of People Evacuated Estimated Number of Buildings 1 1 2 - Suburban - Predominantly single family residential 1 - Square Feet 10000 1 - Square Feet 10000 50 1 Page: 1 Printed: 04/16/2005 00:43:37 incident Report 2005-0501204-000 Tukwila Fire Department Hazmat Hazmat Action Taken 1 Hazmat Action Taken 2 Cause of Release Factors Contributing To Release 1 Disposition Equipment Type 34 - Investigate 32 - Notify other agencies 3 - Container or containment failure 54 - Other part failure, leak, or break 8 - Released to property owner or manager 373 - Gas regulator Page: 2 Printed: 04/16/2005 00:43:37 Hazmat Chemicals Chemical Name DOT ID Container Type Physical State When Released Released Into Natural gas 21- Division 2.1 Flammable gases 22 - Pipe or Pipeline 3 - Gas 1 - Air Apparatus - E53 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Action Taken 2 Apparatus Type Personnel 1 Personnel 2 Personnel 3 E53 0:03:22 20:30:11 Friday, April 15, 2005 20:32:04 Friday, April 15, 2005 20:35:26 Friday, April 15, 2005 21:37:23 Friday, April 15, 2005 Yes 3 1 86 - Investigate 45 - Remove hazard 11 - Engine TF1159 - Schell, James Position: FFI TF1145 - Blake, Sally Position: FFI TF1111 - Green, Wilbur D Position: FFI Apparatus - E54 Apparatus ID Apparatus Dispatch Date and Time En route to scene date and time Apparatus Clear Date and Time Apparatus priority response Apparatus cancelled after dispatch Number of People Apparatus Use Apparatus Type Personnel 1 Personnel 2 E54 20:30:11 Friday, April 15, 2005 20:32:16 Friday, April 15, 2005 20:38:06 Friday, April 15, 2005 Yes Yes 4 1 11 - Engine TF1161 - Woolley, Charles Position: FFI TF1185 - Whitcutt, Roy S Position: FFII Page: 2 Printed: 04/16/2005 00:43:37 MC M. Incident Report 2005-0501204-000 Tukwila Fire Department Apparatus - E54 Personnel 3 Personnel 4 TF1181 - Popejoy, Toby Position: FFI TF1174 - Kim, Brandon Position: FFI Apparatus - A19 Apparatus ID Apparatus Dispatch Date and Time En route to scene date and time Apparatus Clear Date and Time Apparatus priority response Apparatus cancelled after dispatch Apparatus Use Apparatus Type A19 20:30:11 Friday, April 15, 2005 20:32:11 Friday, April 15, 2005 20:33:20 Friday, April 15, 2005 Yes Yes 1 75 - BLS unit ross Kef inc#s for each Jurisdiction Involved: #1={ } Updated addl location info: -- ITT TECHNICAL INST Short Report: *ADDR NOT CONFIRMED* ODOR OF GAS, OUTS ON LEFT SIDE OF BLDG AT STUDENT ENTRANCE Page: 3 Printed: 04/16/2005 00:43:37 Apparatus - B51 Apparatus ID Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Type Personnel 1 B51 20:56:43 Friday, April 15, 2005 21:13:06 Friday, April 15, 2005 21:13:06 Friday, April 15, 2005 21:13:06 Friday, April 15, 2005 Yes 1 0 92 - Chief officer car TF1109 - Fehr, Theodore Position: BC Authority Reported By Officer hi Charge Reviewer TF1159 - Schell, James 22:47:20 Friday, April 15, 2005 TF1159 - Schell, James 22:47:22 Friday, April 15, 2005 - Narratives Narrative Name Narrative Type Author Narrative Text CAD Narrative CAD Narrative - CAD Incident Number: TF05001133 ross Kef inc#s for each Jurisdiction Involved: #1={ } Updated addl location info: -- ITT TECHNICAL INST Short Report: *ADDR NOT CONFIRMED* ODOR OF GAS, OUTS ON LEFT SIDE OF BLDG AT STUDENT ENTRANCE Page: 3 Printed: 04/16/2005 00:43:37 Incident Report 2005-0501204-000 Tukwila Fire Department Narratives <20:31:40>NAM: WARNER.ERIK/STUDENT PHO: 2536786027 TXT: SMELL OF ROTTEN EGGS...RP ADVSD MAIN LINE COMES OUT OF GROUND AND INTO METER BOX, THEN INTO BLDG, ODOR IS COMING FROM JUNCTION FROM METER BOX THAT RUNS INTO THE BLDG.. <20:32:13>SO ADVSD LOCN IS NEAR BECU IN TUK.. B51 <20:38:16>,PROCEEDING E53<20:39:13>,VOICE MAIL FOR RP E53<20:42:22>,PSE ETA 20 E53<20:50:12>,LEL OF 10, SHUTTING DOWN LINE EVAC BLDG E53<20:56:31>,GAS TURNED OFF E53<21:01:29>,PSE ON LOC Narrative Name 05-1204 Narrative Type Incident Narrative Date 22:47:27 Friday, April 15, 2005 Author TF1159 - Schell, James Author Rank FFI Author Assignment 1 Narrative Text At 2030 hours on Friday April 15, 2005 we were dispatched to a gas leak. Four units were assigned to this incident. Eight personnel responded. We arrived on scene at 2035 hours and cleared at 2137 hours. The incident occurred at 12720 GATEWAY Dr, Tukwila in District 001. The local station is 53. The general description of this property is adult education center, college classroom. The primary task(s) performed at the scene by responding personnel was investigation. Other special haz mat actions were also taken. Automatic aid was received on this incident. Alarm number 0501204 has been assigned to this incident. E53, E54, A19 dispatched to a reported smell of gas outside a structure. B51 added himself to the call and cancelled A19. E53 arrived to find a 200 by 300 2 story concrete tilt up building not evacuated investigating. E53 investigated and found a small leak of natural gas, downstream from the meter into the building. This was a 1 1/2 inch line. PSE was added to the call. A micro max monitor found readings indicating 14 % of the lel. E53 secured the gas and had the building evacuated and awaited for PSE to arrive. PSE arrived and E53 tied in with PSE advising them of where the problem could be found. E53 assisted PSE with investigation. E53 found a gas leak in a line entering the building through a concrete wall due to rust and corrosion. The rust and corrosion were due to the pipe being exposed to the elements and having the insulation hold the water against the pipe. E53 investigated, performed air monitoring, assisted PSE with investigation. Gas secured to building, PSE Red tagged meter and consulted with ITT Dean with instructions on how to proceed to get the piping fixed. E53 returned in service. Page: 4 Printed: 04/16/2005 00:43:37 Incident Report 2005-0501204-000 Tukwila Fire Department Narratives t James R. Schell 04/16/05 Attachments: Location(\\fdntserver\firerms\incidents\05-1204\) 2 pictures 1 excel spread sheet with air monitoring results End of Report Page: 5 Printed: 04/16/2005 00:43:37 Incident History for Received 04/15/05 Entered 04/15/05 Dispatched 04/15/05 Enroute 04/15/05 Onscene 04/15/05 Closed 04/15/05 :#TF05001133 CN: $TF05001204 20:30:08 BY CR10 /VC6410 20:30:08 BY CR10 /VC6410 20:30:11 BY FD23 /VC4851 20:32:04 20:35:26 21:37:23 Initial Type:NGASXT TG: Initial Alarm Level:1 Final Type:NGASXT (NATURAL GAS LEAK OUTSIDE (5A))Pri:1Dispo: Lev: 1 Police TP100 Fire TF5351 Grp:T7Beat: Lt/Lg: Police Rms: Fire Rms: Medic Rms: S-#100 Loc:12720 GATEWAY DR ,TUK -- ITT TECHNICAL INST (V) Name:/STUDENT Addr: Phone: 20:30:08 VC6410 CR10 Alrm ENTRY *ADDR NOT CONFIRMED* ODOR OF GAS, OUTS 0 N LEFT SIDE OF BLDG AT STUDENT ENTRANCE $TF05001204 #TF1159 SCHELL, JIM #TF1145 BLAKE, SALLY #TF1111 GREEN, DAVE C/F3 ASST E54 #TF1161 WOOLLEY, CHUCK #TF1185 WHITCUTT, ROY #TF1181 POPEJOY, TOBY #TF1174 KIM, BRANDON C/F3 #HF1166 SYKES, KEVIN #HF1353 LUND, BRIAN C/F3 $HF05001355 GRP: T9 ---> T7. NAM: WARNER.ERIK/STUDENT PHO: 2536786027 TXT: SMELL OF ROTTEN EGGS...RP ADVSD MAI N LINE COMES OUT OF GROUND AND INTO METE R BOX, THEN INTO BLDG, ODOR IS COMING FR OM JUNCTION FROM METER BOX THAT RUNS INT O THE BLDG.. 20:30:07 CR10 $ASNCAS 20:30:11 VC4851 FD23 DISP E53 20:30:11 FD23 20:30:11 FD23 ASST A19 20:30:11 FD23 ASNCAS A19 20:30:46 FD23 CONTRL 20:31:40 VC6410 CR10 SUPP 20:32:04 TF1159 E53 *ENROUT E53 20:32:11 HF1166 A19 *ENROUT A19 20:32:13 VC6410 CR10 SUPP 20:32:15 VC7473 FD24 ASSTER B51 20:32:16 TF1161 E54 *ENROUT E54 20:33:20 VC7473 FD24 CDGRN A19 TXT: RP ALSO ADVSD LOCN IS NEAR BECU IN TUK. [12720 GATEWAY DR ,TUK] #TF1109 FEHR, TE D ,A19 IS CODE GREENED FROM #TF05001133 - 12720 GATEWAY DR ,TUK 2Q:33:25 FD24 CLEAR A19 20:35:26 FD24 ONSCNE E53 , 300X200 CCTU BLDG NOT EVAC, ALL UNITS STAND BY ON GATEWAY 20:38:06 FD24 CDGRN E54 ,E54 IS CODE GREENED FROM #TF05001133 - 12720 GATEWAY DR ,TUK 20:38:16 FD24 MISC B51 ,PROCEEDING 20:38:18 FD24 CLEAR E54 20:39:13 FD24 MISC E53 ,VOICE MAIL FOR RP 20:39:34 TF1109 B51 *ONSCNE B51 20:42:22 VC7473 FD24 MISC E53 ,PSE ETA 20 20:44:18 TF1109 B51 *OLIS B51 20:44:20 B51 MOBINS B51 20:50:12 VC7473 FD24 MISC E53 ,LEL OF 10, SHUTTING DOWN LINE EVAC BLDG 20:56:31 FD24 MISC E53 ,GAS TURNED OFF 20:56:43 FD24 ASSTOS B51 [12720 GATEWAY DR ,TUK] #TF1109 FEHR, TE D 21:01:29 FD24 MISC E53 ,PSE ON LOC 21:13:06 TF1109 B51 MOBINS B51 21:37:23 VC7473 FD24 CLEAR E53 21:37:23 FD24 CLOSE E53