HomeMy WebLinkAboutHAZMAT 05-4088 - 16840 SOUTHCENTER PKWY - GAS LEAK ON 11/15/200516840 SOUTHCENTER PKWY
GAS LEAK
HAZMAT # 05-4088
rt
Incident Report
2005-0504088-000
Tukwila Fire Department
Page: 1
Printed: 11/15/2005 12:46:46
Basic
'
Alarm Date and Time
Arrival Time
Controlled Date and Time
Last Unit Cleared Date and Time
Response Time
Priority Response
Completed
Fire Department Station
Shift
Incident Type
Aid Given or Received
Mutual Aid Department
Alarms
Action Taken 1
Action Taken 2
Action Taken 3
Apparatus - Suppression
Personnel - Suppression Personnel
Property Loss
Contents Loss
Property Value
Contents Value
Hazardous Material Released
Property Use
Location Type
Address
City, State Zip
District
Census Tract
Directions
08:54:30 Tuesday, November 15, 2005
09:00:53
09:32:19 Tuesday, November 15, 2005
0:06:23
Yes
Yes
51
B
412 - Gas leak (natural gas or LPG)
2 - Automatic aid received
17M08
1
86 - Investigate
42 - Hazmat detection, monitoring, sampling, & analysis
51 - Ventilate
6
7
$0.00
$0.00
$0.00
$0.00
0 - Special hazmat actions required or spill greater than 55 gallons
580 - General retail, other
Address
16840 Southcenter PKY
TUKWILA, WA 98188
006
0262.00
16840 SOUTHCENTER PY ,TUK
Additional Mutual Aid Agencies
Aid Department
Renton Fire Department
.4
Person Involved - Aranda, Bre
Involvement Code
Name Prefix
Last Name
First Name
Business Name
Street Address
City, State Zip
Phone
MGR
MS
Aranda
Brenda
JARED Galleria of Jewelry
16840 Southcenter PKY
TUKWILA, WA 98188
2065752428
Hazmat
Area Affected
Area Affected Unites
Cause of Release
1 - Square Feet
3000
2 - Unintentional release
Page: 1
Printed: 11/15/2005 12:46:46
Incident Report
2005-0504088-000
Tukwila Fire Department
Hazmat
Factors Contributing To Release 1
Disposition
52 - Manual control failure
7 - Released to private agency
Apparatus - B51
Apparatus ID
Response Time
Apparatus Dispatch Date and Time
En route to scene date and time
Apparatus Arrival Date and Time
Apparatus Clear Date and Time
Apparatus priority response
Number of People
Apparatus Use
Apparatus Type
Personnel 1
B51
0:01:42
08:55:29 Tuesday, November 15, 2005
08:59:11 Tuesday, November 15, 2005
09:00:53 Tuesday, November 15, 2005
09:27:56 Tuesday, November 15, 2005
Yes
1
1
92 - Chief officer car
TF 1109 - Fehr, Theodore
Position: BC
Apparatus - E52
Apparatus ID
Response Time
Apparatus Dispatch Date and Time
En route to scene date and time
Apparatus Arrival Date and Time
Apparatus Clear Date and Time
Apparatus priority response
Number of People
Apparatus Use
Apparatus Type
Personnel 1
Personnel 2
Personnel 3
E52
0:05:09
08:55:29
09:01:26
09:06:35
09:19:30
Yes
3
1
11- Engine
TF1139 - Borden, John
Position: LT
TF1111 - Green, Wilbur D
Position: FFI
TF 1142 - Bennatts, Robert
Position: FFI
Tuesday, November 15, 2005
Tuesday, November 15, 2005
Tuesday, November 15, 2005
Tuesday, November 15, 2005
Apparatus - E521
Apparatus ID
Response Time
Apparatus Dispatch Date and Time
En route to scene date and time
Apparatus Arrival Date and Time
Apparatus Clear Date and Time
Apparatus priority response
Number of People
Apparatus Use
Apparatus Type
Personnel 1
E521
0:04:11
08:55:29 Tuesday, November 15, 2005
08:58:04 Tuesday, November 15, 2005
09:02:15 Tuesday, November 15, 2005
09:32:19 Tuesday, November 15, 2005
Yes
3
1
11 - Engine
TF 1119 - McFarland, Loren
Position: LT
Page: 2
Printed: 11/15/2005 12:46:46
Incident Report
2005-0504088-000
Tukwila Fire Department
Apparatus - E521
Personnel 2
Personnel 3
TF1181- Popejoy, Toby
Position: FFI
TF 1127 - Lindsey, Jim
Position: FFIII
Apparatus - E14
Apparatus ID
Response Time
Apparatus Dispatch Date and Time
En route to scene date and time
Apparatus Arrival Date and Time
Apparatus Clear Date and Time
Apparatus priority response
Apparatus Use
Apparatus Type
E14
0:05:57
08:55:29
08:57:03
09:03:00
09:25:53
Yes
1
11 - Engine
Tuesday, November 15, 2005
Tuesday, November 15, 2005
Tuesday, November 15, 2005
Tuesday, November 15, 2005
Apparatus - A74
Apparatus ID
Response Time
Apparatus Dispatch Date and Time
En route to scene date and time
Apparatus Arrival Date and Time
Apparatus Clear Date and Time
Apparatus priority response
Apparatus Use
Apparatus Type
A74
0:14:37
08:55:29 Tuesday, November 15, 2005
08:57:40 Tuesday, November 15, 2005
09:12:17 Tuesday, November 15, 2005
09:30:45 Tuesday, November 15, 2005
Yes
1
75 - BLS unit
Apparatus - L74
Apparatus ID
Response Time
Apparatus Dispatch Date and Time
En route to scene date and time
Apparatus Arrival Date and Time
Apparatus Clear Date and Time
Apparatus priority response
Apparatus Use
Apparatus Type
L74
0:14:28
08:55:29
08:57:57
09:12:25
09:18:59
Yes
1
13 - Quint
Tuesday, November 15, 2005
Tuesday, November 15, 2005
Tuesday, November 15, 2005
Tuesday, November 15, 2005
Authority
Reported By
Officer In Charge
Reviewer
Narrative Name
TF 1119 - McFarland, Loren
12:34:01 Tuesday, November 15, 2005
09 - F = Theodore
Tue day, No
Narrat es
CAD Narrative
Page: 3
Printed: 11/15/2005 12:46:46
•
Incident Report
2005-0504088-000
Tukwila Fire Department
Narratives
Narrative Type CAD Narrative
Author
Narrative Text CAD Incident Number: TF05003849
Cross Ref Inc#s for each Jurisdiction Involved:
#1={ }
Updated addl location info:
-- JARED JEWELRY
Short Report:
NOW ...ODORIN...SMELLS LIKE NATURAL GAS...FAIRLY STRONG...
<08:57:14>NAM: ARANDA,BRENDA/MGR CON: Y TXT: ..NO NATGAS
HEATING...RP SAYS USED SOME KIND OF GAS FOR TORCHES IN BACK OF
STORE...**WILL EVAC
B51<09:04:34>, PSE FOR GAS NEEDED
B51<09:06:22>, SHUTTING OFF GAS METER
B51<09:12:54>, PSE ENR, ETA 20
Narrative Name 0504088
Narrative Type Incident
Narrative Date 12:37:16 Tuesday, November 15, 2005
Author TF 1119 - McFarland, Loren
Author Rank LT
Author Assignment 1
Narrative Text At 0854 hours on Tuesday November 15, 2005 we were dispatched to a gas leak. Six units
were assigned to this incident. Seven personnel responded. We arrived on scene at 0900
hours and cleared at 0932 hours. The incident occurred at 16840 Southcenter Pky,
TUKWILA in District 006. The local station is 51. The general description of this property
is general retail. The primary task(s) performed at the scene by responding personnel was
investigation. Other special haz mat actions were also taken. Automatic aid was received
on this incident.
Alarm number 0504088 has been assigned to this incident.
Upon arrival manager met us outside and stated that there was a strong odor of natural gas
inside of the business. Entered the business and did have a moderate odor of natural gas in
the business. Security went with us. He states that there has been no recent work.
Checked in the manufacturing area where they have three stations with torches and found
no leaks there. Obtained the micromax from B-51 and went back inside to check the area
out further. In the back storeroom and the restrooms the micromax did give brief readings
of 2 percent LEL. B-51 had the gas meter shut down for this occupancy. Odor started to
disipate. PSE arrived and he found low levels of gas in the manufacturing area and then in
the back storage area. In the storage area a flex line branches off of fixed piping and goes
to the manufacturing area. PSE did not think that this supplied the torches in
manufacturing but investigating found that it did. PSE believes that a torch was slightly
leaking all night but they are going to perform a pressure test on the building interior
system.
E-521 in service/ returning.
NOTE- did find that in the riser room the fire alarm panel is in trouble and is showing a
Page: 4 Printed: 11/15/2005 12:46:46
r
Incident Report
2005-0504088-000
Tukwila Fire Department
Narratives
trouble on the supervisory side.
End of Report
Page: 5 Printed: 11/15/2005 12:46:46
Incident History for:#TF05003849 CN: $TF05004088
$eceived 11/15/05 08:54:30 BY CR16 /EMECON
Entered 11/15/05 08:55:20 BY CR16 /EMECON
Dispatched 11/15/05 08:55:29 BY FD23 /VCO262
Enroute 11/15/05 08:57:03
Onscene 11/15/05 09:00:53
Closed 11/15/05 09:32:19
0.-(-10W
Initial Type:NGASIN TG: Initial Alarm Level:1
Final Type:NGASIN (NATURAL GAS LEAK INSIDE (2A))Pri:lDispo: Alrm L
ev: 1
Police TP1000 Fire TF5131 Grp:T7Beat: Lt/Lg:
Police Rms: Fire Rms: Medic Rms:
Loc:16840 SOUTHCENTER PY ,TUK -- JARED JEWELRY (V)
Name:ARANDA,BRENDA/MGR Addr:JARED GALLERIA OF JEWELPhone:2065752428
Contact:Y
08:55:20 EMECON CR16 ENTRY NOW ...ODORIN...SMELLS LIKE NATURAL GAS.
..FAIRLY STRONG...
08:55:20 CR16 $ASNCAS $TF05004088
08:55:29 VCO262 FD23 DISP E52 #TF1139 BORDEN, JOHN
#TF1111 GREEN, DAVE
#TF1142 BENNATTS, ROB
C/F3
08:55:29 FD23 ASST E521 #TF1119 MCFARLAND, LOREN
#TF1181 POPEJOY, TOBY
#TF1127 LINDSEY, JAMES E
C/F3
08:55:29 FD23 ASST E14 #RF0164 KUNKEL, STEWART
#RF0167 SLOTHOWER, CHIP
#RF0180 POWELL, DANIEL
C/F3
08:55:29 FD23 ASNCAS E14 $RF05008186
08:55:29 FD23 ASST A74 #KF0180 SMITH, STEVE
#KF0203 WALTRIP, JIM
C/F3
08:55:29 FD23 ASNCAS A74 $KF05012343
08:55:29 FD23 ASST L74 #KF0066 KING, J.T.
#KF0184 BARBERIE, DON
#KF0231 SCHAFER, ERIC
C/F3
08:55:29 FD23 ASST B51 #TF1109 FEHR, TED
C/F3
08:55:29 FD23 ASST TFINFO #TFINFO TUKWILA CHIEF INFO PAGER
C/F3
08:55:35 FD23 IQIS TFINFO
08:56:36 FD23 CONTRL GRP: T9
---> T7.
08:57:03 VC2092 FD24 ENROUT E14
08:57:14 EMECON CR16 SUPP NAM: ARANDA,BRENDA/MGR
4 • Y
08:57:40
08:57:57
08:58:04
08:59:11
08:59:20
08:59:26
09:00:53
09:01:26
09:02:15
09:03:00
09:04:34
09:05:36
09:06:22
09:06:35
09:11:58
09:12:17
09:12:25
09:12:43
09:12:54
09:18:59
09:19:30
09:20:17
09:20:17
09:20:17
09:20:17
09:25:53
09:27:56
09:28:34
09:30:45
09:32:19
09:32:19
KF0180
KF0066
VC2092
TF1109
KF0180
VC2092
KF0066
TF1139
VC2092
A74 *ENROUT A74
L74 *ENROUT L74
FD24 ENROUT E521
FD24 ENROUT B51
FD24 CHGLOC E521
FD24 CHGLOC B51
FD24 ONSCNE B51
FD24 ENROUT E52
FD24 ONSCNE E521
FD24 ONSCNE E14
FD24 MISC B51
FD24 NEWLOC B51
FD24 MISC B51
FD24 ONSCNE E52
B51 *ENROUT B51
A74 *ONSCNE A74
FD24 ONSCNE L74
FD24 ONSCNE B51
FD24 MISC B51
L74 MOBINS L74
E52 MOBINS E52
FD24 OK A74
FD24 OK B51
FD24 OK E14
FD24 OK E521
VCO262 FD23
VC2092 FD24
FD24
KF0180 A74
VC2092 FD24
FD24
CLEAR E14
CLEAR B51
AVL E521
MOBINS A74
MOBINS E521
CLOSE E52
CON: Y
TXT: ..NO NATGAS HEATING...RP SAYS USED
SOME KIND OF GAS FOR TORCHES IN BACK OF
STORE...**WILL EVAC
[FRONT]
[BACK]
[FRONT]
, INV
, PSE FOR GAS NEEDED
[SOUTHCENTER CMD -SIDE B]
, SHUTTING OFF GAS METER
, PSE ENR, ETA 20
, CODE 4 OUTSIDE,
THE PANCOM
, CODE 4 OUTSIDE,
THE PANCOM
, CODE 4 OUTSIDE,
THE PANCOM
, CODE 4 OUTSIDE,
THE PANCOM
WILL CHECK
WILL CHECK
WILL CHECK
WILL CHECK
INSIDE FOR
INSIDE FOR
INSIDE FOR
INSIDE FOR