Loading...
HomeMy WebLinkAboutHAZMAT 06-1819 - 18323 ANDOVER PARK WEST - GAS LEAK ON 5/31/200618323 ANDOVER PARK WEST GAS LEAK HAZMAT # 06-1819 Incident Report 2006-0601819 -000 Tukwila Fire Department Page: 1 Printed: 05/31/2006 08:05:16 Basic Alarm Date and Time Arrival Time Controlled Date and Time Last Unit Cleared Date and Time Response Time Priority Response Completed Fire Department Station Shift Incident Type Initial Dispatch Code Aid Given or Received Alarms Action Taken 1 Apparatus - Suppression Personnel - Suppression Personnel Hazardous Material Released Property Use Location Type Address City, State Zip District Census Tract Directions 04:24:22 Wednesday, May 31, 2006 04:33:58 05:17:19 Wednesday, May 31, 2006 0:09:36 Yes Yes 51 A 412 - Gas leak (natural gas or LPG) na N - None 1 45 - Remove hazard 6 12 0 - Special hazmat actions required or spill greater than 55 gallons 891- Warehouse Address 18323 Andover PARK W Tukwila, WA 98188 006 0262.00 18323 ANDOVER PK W ,TUK Person Involved - ATKINS,WAKEMBIE/EMPL, Involvement Code Last Name Street Address Phone REP ATK NS,WAKEMBIE/EMPL SURFACE ART INC 2063154565 Hazmat Area Affected Area Affected Unites Cause of Release Factors Contributing To Release 1 Disposition Mobile Equipment Type Equipment Type 2 - Blocks 1 2 - Unintentional release 71- Collision, overturn, knockdown 7 - Released to private agency 63 - Loader - industrial, fork lift, tow motor, stacker 131- Furnace, local heating unit, built-in Hazmat Chemicals Chemical Name DOT ID Natural gas 21 - Division 2.1 Flammable gases Apparatus - E51 Apparatus ID Response Time Apparatus Dispatch Date and Time E51 0:03:41 04:26:01 Wednesday, May 31, 2006 Page: 1 Printed: 05/31/2006 08:05:16 Incident Report 2006-0601819 -000 Tukwila Fire Department Page: 2 Printed: 05/31/2006 08:05:16 Apparatus - E51 En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 Personnel 3 04:30:17 Wednesday, May 31, 2006 04:33:58 Wednesday, May 31, 2006 05:17:19 Wednesday, May 31, 2006 Yes 3 1 45 - Remove hazard 11 - Engine TF1117 - Lyons, Philip Position: LT TF1146 - Curl, Joel Position: FFP TF1159 - Schell, James /zj Position: FFI Apparatus - B51 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 B51 0:03:43 04:26:01 Wednesday, May 31, 2006 04:30:18 Wednesday, May 31, 2006 04:34:01 Wednesday, May 31, 2006 05:08:48 Wednesday, May 31, 2006 Yes 1 1 81 - Incident command 92 - Chief officer car TF1122 - Peterson, Lavern Position: BC Apparatus - E52 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 Personnel 3 E52 0:06:44 04:26:01 Wednesday, May 31, 2006 04:28:28 Wednesday, May 31, 2006 04:35:12 Wednesday, May 31, 2006 05:00:45 Wednesday, May 31, 2006 Yes 3 1 42 - Hazmat detection, monitoring, sampling, & analysis 11 - Engine TF 1163 - Rydeen, Steven Position: FFI TF1110 - Nevens, Andrew Position: FFIII TF1155 - Karwhite, Jason Position: FFI Page: 2 Printed: 05/31/2006 08:05:16 Incident Report 2006-0601819 -000 Tukwila Fire Department Apparatus - A54 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 A54 0:07:07 04:26:01 04:30:16 04:37:23 04:57:45 Yes 2 1 42 - Hazmat detection, monitoring, sampling, & analysis 75 - BLS/Aid unit TF1133 - McCone, Daniel Position: FFI TF 1165 - Brooks, James Position: FFI Wednesday, May 31, 2006 Wednesday, May 31, 2006 Wednesday, May 31, 2006 Wednesday, May 31, 2006 Apparatus - E14 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Use Apparatus Action Taken 1 Apparatus Type E14 0:08:32 04:26:01 Wednesday, May 31, 2006 04:29:01 Wednesday, May 31, 2006 04:37:33 Wednesday, May 31, 2006 04:40:49 Wednesday, May 31, 2006 Yes 1 93 - Cancelled en route 11- Engine Apparatus - L54 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 Personnel 3 L54 0:08:30 04:26:01 04:29:39 04:38:09 05:12:01 Yes 3 1 51 - Ventilate 13 - Quint TF1138 - Roberts, Martin Position: LT TF1178 - Rees, Richard Position: FFI TF 1140 - Codenys, Alan Position: FFI Wednesday, May 31, 2006 Wednesday, May 31, 2006 Wednesday, May 31, 2006 Wednesday, May 31, 2006 Authority Page: 3 Printed: 05/31/2006 08:05:16 Incident Report 2006-0601819 -000 Tukwila Fire Department Authority Reported By Officer In Charge Reviewer TF1117 - Lyons, Philip 07:40:45 Wednesday, May 31, 2006 TF1117 - Lyons, Philip 07:40:45 Wednesday, May 31, 2006 Narratives Narrative Name Narrative Type Author Narrative Text CAD Narrative CAD Narrative CAD Incident Number: TF06001739 Cross Ref Inc#s for each Jurisdiction Involved: #1={ Updated addl location info: — SURFACE ART Short Report: NOW, NATURAL GAS LEAK INSIDE <04:26:40>TXT: HIT NATURAL GAS LINE WITH FORKLIFT, 3 EMPLOYEES EVACUATING, WILL WAIT OUT SIDE <04:37:12>TXT: 1ST RESPONDER OUT OF BURIEN - ETA 15 MINS <04:28:34>, PSE WILL CALL BACK W/ETA B51<04:35:05>, NOTHING ON SIDE C E51<04:36:13>, ALL INCOMING STANDBY ON APW A54<04:38:33>, METER DIRECTLY ACROSS FROM E52 B51<04:39:15>, GAS LINE GOES TO THE HANGING HEATER INS THE WHSE B51<04:40:51>, GAS SECURE , E14 GREEN, L54 COME TO LOC TO VENTILATE B51<04:48:33>, E52 OFC 2ND STORY N SIDE A54<04:49:14>, NO READINGS E52<04:49:20>, NO READINGS A54<04:49:35>,OPENED LARGE ROLLUP DOOR ON NW CORNER OF THE BLDG E52<04:53:11>, DETECTOR GO OFF A COUPLE TIMES JUST FOR POCKETS BUT NOTHING CONSISTENT .. 1 ON NW CORNER AND 1 UP ON E CORNER 2ND FLR OFC B51<04:56:47>045647, PSE ON LOC B51<05:07:44>,TERMINATING ANDOVER PK W CMD E51<05:07:59>, TAKING CMD Narrative Name New Narrative Narrative Type Incident Narrative Date 07:40:49 Wednesday, May 31, 2006 Author TF1117 - Lyons, Philip Author Rank LT Author Assignment 1 Narrative Name New Narrative Narrative Type Incident Narrative Date 07:56:08 Wednesday, May 31, 2006 Author TF1117 - Lyons, Philip Page: 4 Printed: 05/31/2006 08:05:16 Incident Report 2006-0601819 -000 Tukwila Fire Department Narratives Author Rank Author Assignment Narrative Text LT 1 At 0424 hours on Wednesday May 31, 2006 we were dispatched to a gas leak. Six units were assigned to this incident. Twelve personnel responded. We arrived on scene at 0433 hours and cleared at 0517 hours. The incident occurred at 18323 Andover Park W, Tukwila in District 006. The local station is 51. The general description of this property is warehouse. The primary task(s) performed at the scene by responding personnel was hazard removal. Other special haz mat actions were also taken. No mutual/automatic aid was given or received. Alarm number 0601819 has been assigned to this incident. Dispatched to NG leak inside building. Found tilt up warehouse evacuated and ventilated by employees. Units on scene shut gas meter, monitored vapors and performed additional ventilation. No significant vapors detected from cieling hung space heater struck by forklift. WNG locked meter and instructed employees on proceedure to restore service following repair to heater. End of Report Page: 5 Printed: 05/31/2006 08:05:16 Incident History for: Received 05/31/06 Entered ' 05/31/06 Dispatched 05/31/06 Enroute 05/31/06 Onscene 05/31/06 Closed 05/31/06 #TF06001739 CN: $TF06001819 04:24:22 BY CR08 /VC8731 04:25:54 BY CR08 /VC8731 04:26:01 BY FD23 /VC0025 04:28:28 04:33:58 05:17:19 Initial Type:NGASIN TG: Initial Alarm Level:1 Final Type:NGASIN (NATURAL GAS LEAK INSIDE (2A))Pri:lDispo: ev: 1 Police TP1200 Fire TF5139 Grp:T9Beat: Lt/Lg: Police Rms: Fire Rms: Medic Rms: Loc:18323 ANDOVER PK W ,TUK -- SURFACE ART (V) Name:ATKINS,WAKEMBIE/EMPL Addr:SURFACE ART INC 04:25:54 VC8731 CR08 ENTRY 04:25:54 CR08 $ASNCAS 04:26:01 VO0025 FD23 DISP E51 04:26:01 04:26:01 04:26:01 04:26:01 Alrm L Phone:2063154565 NOW, NATURAL GAS LEAK INSIDE $TF06001819 #TF1117 LYONS, PHIL #TF1146 CURL, JOEL #TF1159 SCHELL, JIM C/F3 FD23 ASST E52 #TF1163 RYDEEN, STEVE #TF1110 NEVENS, ANDY #TF1155 KARWHITE, JASON C/F3 FD23 ASST E14 #RF0105 #RF0094 #RF0114 C/F3 FD23 ASNCAS E14 $RF06003942 FD23 ASST A54 #TF1133 MCCONE, DAN J #TF1165 BROOKS, JIM C/F3 ASST L54 #TF1138 ROBERTS, MARTY #TF1178 REES, RICHARD #TF1140 CODENYS, ALAN C/F3 ASST B51 #TF1122 PETERSON, LAVERN C/F3 ASST TFINFO #TFINFO TUKWILA CHIEF INFO PAGER C/F3 IQIS TFINFO SUPP TXT: HIT NATURAL GAS LINE WITH FORKLIFT, 3 EMPLOYEES EVACUATING, WILL WAIT OUT S IDE WELCH, LARRY SPROAT, CHRIS CURTIS, TOM 04:26:01 FD23 04:26:01 FD23 04:26:01 FD23 04:26:17 VC7215 FD22 04:26:40 VC8731 CR08 04:28:28 TF1163 E52 04:28:34 VO0025 FD23 04:29:01 RF0105 E14 04:29:39 TF1138 L54 *ENROUT E52 MISC *ENROUT E14 *ENROUT L54 , PSE WILL CALL BACK W/ETA 04:30:16 TF1133 A54 *ENROUT A54 04:30:`17 TF1117 E51 *ENROUT E51 04:0:18' V00025 FD23 ENROUT B51 04:33:58 FD23 ONSCNE E51 , LARGE SS CCT EVAC VENT 360 LOOKING FOR GAS METER 04:34:01 FD23 ONSCNE B51 04:34:20 FD23 NEWLOC B51 [ANDOVER PK W CMD SIDE A ] 04:35:05 FD23 MISC B51 , NOTHING ON SIDE C 04:35:12 FD23 ONSCNE E52 , STANDING BY HYDRANT 04:36:13 FD23 MISC E51 , ALL INCOMING STANDBY ON APW 04:37:12 VC7872 CRO2 SUPP NAM: PSE TXT: 1ST RESPONDER OUT OF BURIEN - ETA 1 5 MINS 04:37:23 VC3690 FD23 ONSCNE A54 04:37:33 RF0105 E14 *ONSCNE E14 04:38:09 TF1138 L54 *ONSCNE L54 04:38:33 VC3690 FD23 MISC A54 , METER DIRECTLY ACROSS FROM E52 04:39:15 FD23 MISC B51 , GAS LINE GOES TO THE HANGING HEATER IN S THE WHSE 04:40:49 RF0105 E14 MOBINS E14 04:40:51 VC3690 FD23 MISC B51 , GAS SECURE , E14 GREEN, L54 COME TO LO C TO VENTILATE 04:41:01 FD23 NEWLOC L54 [VENTILATE ] 04:43:41 FD23 NEWLOC A54 [INS] , AIR SAMPLING 04:43:41 FD23 NEWLOC E52 [INS] , AIR SAMPLING 04:48:33 FD23 MISC B51 , E52 OFC 2ND STORY N SIDE 04:49:14 FD23 MISC A54 , NO READINGS 04:49:20 FD23 MISC E52 , NO READINGS 04:49:35 FD23 MISC A54 ,OPENED LARGE ROLLUP DOOR ON NW CORNER 0 F THE BLDG 04:53:11 FD23 MISC E52 , DETECTOR GO OFF A COUPLE TIMES JUST FO R POCKETS BUT NOTHING CONSISTENT .. 1 ON NW CORNER AND 1 UP ON E CORNER 2ND FLR OFC 04:54:33 FD23 OLIS A54 04:56:47 FD23 MISC B51 , PSE ON LOC 04:57:45 TF1133 A54 MOBINS A54 04:58:50 TF1163 E52 *OLIS E52 05:00:45 E52 MOBINS E52 05:07:44 VC3690 FD23 MISC B51 ,TERMINATING ANDOVER PK W CMD 05:07:59 FD23 MISC E51 , TAKING CMD 05:08:48 FD23 MOBINS B51 05:12:01 TF1138 L54 MOBINS L54 05:17:19 TF1117 E51 MOBINS E51 05:17:19 E51 CLOSE E51