Loading...
HomeMy WebLinkAboutHAZMAT 07-0130 - 225 ANDOVER PARK WEST - CARBON MONOXIDE INCIDENT ON 1/11/2007225 ANDOVER PARK WEST CARBON MONOXIDE INCIDENT HAZMAT # 07-0130 Incident Report 2007-0700130 -000 Tukwila Fire Department o ( o Page: 1 Printed: 01/11/2007 20:38:45 Basic Alarm Date and Time Arrival Time Controlled Date and Time Last Unit Cleared Date and Time Response Time Priority Response Completed Fire Department Station Shift Incident Type Initial Dispatch Code Aid Given or Received Alarms Action Taken 1 Apparatus - Suppression Personnel - Suppression Personnel Hazardous Material Released Property Use Location Type Address City, State Zip District Census Tract Directions 18:05:55 Thursday, January 11, 2007 18:11:38 18:48:12 Thursday, January 11, 2007 0:05:43 Yes Yes 51 C 424 - Carbon monoxide incident 14R2 N - None 1 86 - Investigate 3 7 0 - Special hazmat actions required or spill greater than 55 gallons 596 - Post office or mailing firms Address 225 Andover PARK W Tukwila, WA 98188 004 0262.00 225 ANDOVER PK W ,TUK Person Involved - SHAWNA/EMP, Involvement Code Last Name Street Address Phone REP SHAWNA/EMP UNITED STATES GOVERN OK 2062437079 Hazmat Inside/On Structure Flag Story of Release Population Density Area Affected Area Affected Unites Cause of Release Factors Contributing To Release 1 Disposition Equipment Type 1 1 1- Urban Center - Densely populated 1 - Square Feet 1000 2 - Unintentional release 50 - Mechanical failure, malfunction, other 2 - Completed with fire service present 131 - Furnace, local heating unit, built-in Hazmat Chemicals Chemical Name Hazardous Material Apparatus - E51 Apparatus ID Response Time E51 0:02:04 Page: 1 Printed: 01/11/2007 20:38:45 e A Incident Report 2007-0700130 -000 Tukwila Fire Department Apparatus - E51 Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Action Taken 2 Apparatus Type Personnel 1 Personnel 2 Personnel 3 18:07:44 18:09:34 18:11:38 18:48:12 Yes 3 1 86 - Investigate 55 - Establish safe area 11- Engine TF 1114 - Konieczka, Jason Position: LT TF1166 - Butler, Wesley Position: FFI TF1107 - Nichols, Jeff Position: FFI Thursday, January 11, 2007 Thursday, January 11, 2007 Thursday, January 11, 2007 Thursday, January 11, 2007 Apparatus - E52 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Action Taken 2 Apparatus Type Personnel 1 Personnel 2 Personnel 3 E52 0:05:04 18:10:42 18:12:34 18:17:38 18:47:03 Yes 3 1 86 - Investigate 51 - Ventilate 11 - Engine TF1132 - Lucero, Brian Position: FFI TF1181- Popejoy, Toby Position: FFI TF 1127 - Lindsey, Jim Position: FFII Thursday, January 11, 2007 Thursday, January 11, 2007 Thursday, January 11, 2007 Thursday, January 11, 2007 Apparatus - B51 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 B51 0:25:07 18:21:47 Thursday, January 11, 2007 18:46:54 Thursday, January 11, 2007 18:21:47 Thursday, January 11, 2007 18:46:54 Thursday, January 11, 2007 Yes 1 1 70 - Assistance, other Page: 2 Printed: 01/11/2007 20:38:45 Incident Report 2007.0700130 -000 Tukwila Fire Department Cross Ref Inc#s for each Jurisdiction Involved: #1={ } Updated addl location info: -- US POSTAL SERVICE Short Report: NO FURTHER INFORMATION <18:06:44>TXT: NOW & FOR PAST - ALL DAY EMPS & CUSTS FEELING ILL FROM UNK SOURCE ODOR... POSS NAT GAS... <18:08:20>A/EMP TXT: HAVE FURNACE THAT WONT SHUT OFF, UNK IF FURNACE IS GAS POWERED. 4 SUBJS INSIDE C/O HEADACHE & DIZZY, NAUSEA & 1 PT: VOMIT 1X... STORE IS NOW CLOSED... BUT NOT EVACD AT THIS TIME. 2007011118 <18:09:36>TXT: RP IS PT #1: 55 YOF, CONS BREATH NORM HAS KIDNEY PROBS... C/O HEADACHE. ** 4 PT'S TOTAL** #2:24 YOF, CONS, BREATH NORM... C/O HEADACHE NAUSEA NO VOMIT . <18:11:09>TXT: PT #3: 52 YOF, CONS, BREATH NORM, FEELS SHAKEY, NAUSEA DIZZY, VOMIT 2X IN PAST 30 MINS... NO MED HX/MED. THIS PT GOING TO STEP OUTSIDE FOR SOME AIR BU T STATES SHE NEEDS TO STAY TO CLOSE UP. <18:12:58>TXT: PT #4:47 YOM, CONS, BREATH NORM... C/O HEADACHE, DIZZY, NO NAUSEA OR VOMI T.. HAS BEEN INSIDE SINCE 0830 THIS AM. **ONLY 4 TOTAL PTS AT TTHIS TIME** OTHER CUSTS HAD COMPLAINED OF ODOR PRIOR TO LEAVING, NO OTHER KNOWN PTS. E51<18:13:40>, WILL ADV ON AMBS E51<18:15:35>, NO AMBS REQUESTED AT THIS TIME E51<18:17:31>, HAVE 4 EMPL'S, HAVE BEEN HERE ALL DAY, SOME SYMPTOMS, E51 DOES NOT DETECT ANY ODOR, E52 TO BRING IN MICROMAX E51<18:21:41>, SOURCE IS HIGH CARBON MONOXIDE, 300 PPM AROUND FURNACE, 40 PPM INS POST OFC, EVAC NOW E51<18:21:58>, ATTEMPTING TO SHUT OFF THE FURNACE NOW Page: 3 Printed: 01/11/2007 20:38:45 Apparatus - B51 Apparatus Type Personnel 1 92 - Chief officer car TF1108 - Ewing, David Position: BC Authority Reported By Officer In Charge Reviewer TF1114 - Konieczka, Jason 20:37:18 Thursday, January 11, 2007 TF 1114 - Konieczka, Jason 20:37:19 Thursday, January 11, 2007 - , Narratives Narrative Name Narrative Type Author Narrative Text CAD Narrative CAD Narrative - , CAD Incident Number: TF07000117 Cross Ref Inc#s for each Jurisdiction Involved: #1={ } Updated addl location info: -- US POSTAL SERVICE Short Report: NO FURTHER INFORMATION <18:06:44>TXT: NOW & FOR PAST - ALL DAY EMPS & CUSTS FEELING ILL FROM UNK SOURCE ODOR... POSS NAT GAS... <18:08:20>A/EMP TXT: HAVE FURNACE THAT WONT SHUT OFF, UNK IF FURNACE IS GAS POWERED. 4 SUBJS INSIDE C/O HEADACHE & DIZZY, NAUSEA & 1 PT: VOMIT 1X... STORE IS NOW CLOSED... BUT NOT EVACD AT THIS TIME. 2007011118 <18:09:36>TXT: RP IS PT #1: 55 YOF, CONS BREATH NORM HAS KIDNEY PROBS... C/O HEADACHE. ** 4 PT'S TOTAL** #2:24 YOF, CONS, BREATH NORM... C/O HEADACHE NAUSEA NO VOMIT . <18:11:09>TXT: PT #3: 52 YOF, CONS, BREATH NORM, FEELS SHAKEY, NAUSEA DIZZY, VOMIT 2X IN PAST 30 MINS... NO MED HX/MED. THIS PT GOING TO STEP OUTSIDE FOR SOME AIR BU T STATES SHE NEEDS TO STAY TO CLOSE UP. <18:12:58>TXT: PT #4:47 YOM, CONS, BREATH NORM... C/O HEADACHE, DIZZY, NO NAUSEA OR VOMI T.. HAS BEEN INSIDE SINCE 0830 THIS AM. **ONLY 4 TOTAL PTS AT TTHIS TIME** OTHER CUSTS HAD COMPLAINED OF ODOR PRIOR TO LEAVING, NO OTHER KNOWN PTS. E51<18:13:40>, WILL ADV ON AMBS E51<18:15:35>, NO AMBS REQUESTED AT THIS TIME E51<18:17:31>, HAVE 4 EMPL'S, HAVE BEEN HERE ALL DAY, SOME SYMPTOMS, E51 DOES NOT DETECT ANY ODOR, E52 TO BRING IN MICROMAX E51<18:21:41>, SOURCE IS HIGH CARBON MONOXIDE, 300 PPM AROUND FURNACE, 40 PPM INS POST OFC, EVAC NOW E51<18:21:58>, ATTEMPTING TO SHUT OFF THE FURNACE NOW Page: 3 Printed: 01/11/2007 20:38:45 4 Incident Report 2007-0700130 -000 Tukwila Fire Department Narratives Narrative Name Narrative Type Narrative Date Author Author Rank Author Assignment Narrative Text E51<18:37:00>, BLDG IS EVAC, NOW VENTILATING 07-0130 Incident 20:28:03 Thursday, January 11, 2007 TF 1114 - Konieczka, Jason LT 1 At 1805 hours on Thursday January 11, 2007 we were dispatched to a carbon monoxide incident. Three units were assigned to this incident. Seven personnel responded. We arrived on scene at 1811 hours and cleared at 1848 hours. The incident occurred at 225 Andover Park W, Tukwila in District 004. The local station is 51. The general description of this property is post office or mailing firms. The primary task(s) performed at the scene by responding personnel was investigation. Other special haz mat actions were also taken. No mutual/automatic aid was given or received. Alarm number 0700130 has been assigned to this incident. E51 arrived to find Postal Employees complaining of some type of odor. No odor was detected, but the Micromax picked up 40 ppm of CO inside of the building. All employees were asked if they would like medical attention and all said they were o.k. All employees left the building except the person in charge. He stayed to assist with the technician once the building was cleared. The gas was shut down to the building and the furnace was shut down both at the panel and at the furnace. The building was then ventilated with PPV then the windows were left open which created a natural draft from N to S. The CO was checked again and it was no higher than 21 in the entire building. The building was then turned over to the PIC and the maintenance person. It was advised to them if they could not get the furnace working that night that they should place some portable heaters in the building due to the forcast of extremely low temperatures. Battalion 51 remained on scene to monitor the call. It was determined that no command needed to be set up. End of Report Page: 4 Printed: 01/11/2007 20:38:45 Incident Hi Received Entered Dispatched Enroute Onscene' Closed Initial Final Lev: 1 1 11111 M story' f x . 01,/1i/p7 o 11/ 1 I / 0i7H 01/11/07 011/lli/Q7,, 01V11/01'. 01I/11/0i7 Type:AID ' TO: Type:ODORIN (ODOR i' Fire TF0700011'7 C14:1 $TF07000130 18:05:55 BY dR02 /VC2316 18:06:16 BY CRO2 /VC2316 18:07:44 BY FD23 /VC5002 18:09:34 18:11:38 18:48:12 -a(30 Initial Alarm Level:1 INVESTIGATION INDOORS (2A)Pri:2Dispo:14R2 Police TP,60�0 TF5, 21 Grp:T7Beat:, Lt/Lg: Police Rms:Il. Fire Rms: Medic Rms: Loc:225 OVER PK,W4TUK -- US POSTAL SERVICE (V) Name:SHAWN /EMP I Addr:UNITED STATES GOVERNMENPhone:2062437079 Alrm 18:06:16 18:06:16 18:06:44 C2316 ENTRY CRO2; $ASNCAS YC.bi SUPP II11,i 18:06:55 VC50A2' �Fb2� 18:07:32 FD23 H. 18:07:39 18:07:44 FD2 3 P1 1 18:08:04 FD231 18:08:20 V1C2316 18:09:34 TF1114'1 18:09:36 VC2316 C 18:10:33 VC7674 18:10:42 18:10:42 24 VC5002 (FD23 I. FD23 HOLD CHANGE NO FURTHER INFORMATION $TF07000130 TXT: NOW & FOR PAST - ALL DAY EMPS & CUS TS FEELING ILL FROM UNK SOURCE ODOR... P OSS NAT GAS.:. TYP: AID ---> ODORIN. BALNCE Type changed to T/ODORIN DISP E51 #TF1114 KONIECZKA, J. HM TEAM LDR #TF1166 BUTLER, WES #TF1107 NICHOLS, JEFF C/F3 CONTRL ,i GRP: T9 ---> T7. NAM: SHAWNA/EMP TXT: HAVE FURNACE THAT WONT SHUT OFF, UN K IF FURNACE IS GAS POWERED. 4 SUBJS INS IDE C/O HEADACHE & DIZZY, NAUSEA & 1 PT: VOMIT 1X... STORE IS NOW CLOSED... BUT NOT EVAC'D AT THIS TIME. SUPP *ENROUT E5'1 :11SUPP I' CONTRL ASST E52 ASST AMRINF TXT: RP IS PT #1: 55 YOF, CONS BREATH NO RM HAS KIDNEY PROBS... C/O HEADACHE. ** 4 PT'S TOTAL** #2:24 YOF,1CONS, BREATH N ORM... C/O HEADACHE NAUSEA NO VOMIT GRP: T7 ---> T9. ,APPARATUS REQUESTED #TF1132 LUCERO, BRIAN #TF1181 POPEJOY, TOBY #TF1127 LINDSEY, JAMES E C/F3 C/F3 18:10:42 18110:47 VC7674 18:11:05 VC50102 18:11:09 VC2316 18:11:38 18:12:34 18:12:58 I I VC7614) VP24' T1F111321 !E6i2 , VC2316 CRO2 18:13:40 I VC7614 FD24 18:14:25 VC2316 C#IO2' 18:15:35 VC7674; Fb)2 I 18:17:31 ,FU24! II 'E II 18:17:38 18:21:41 IF 18:21:47 FEi2 i 18:21:58 ;F2' 18:28:33 TF11'08 1351 18:37:00 jC76I74' iFp24 18:46:54 F1108 B51 18:46:55 ; VC7614 Fp24i 18:47:03 Fb24, 18:48:12 TF1114 E i1 18:48:12 FEPj2i all ASNCAS1 CLEAR CONTRL:' SUPP ONSCNE E51 *ENROUT E52 SUPP MISC GDISPO MISC E51 MISC ,E5,1 iii N 1 ONSCNE : ! E5�2 MISC 1E511 INF $XF07001508 INF GRP: T9 ---> T7. TXT: PT #3: 52 YOF, CONS, BREATH NORM, F EELS SHAKEY, NAUSEA, DIZZY, VOMIT 2X IN P' AST 30 MINS. NO MED }X/MED. THIS PT GO ING TO STEP OUTSIDE FOR SOME AIR BU T ST ATES SHE NEEDS TO STAY TO CLOSE UP. , NV INV TXT: PT #4:47 YOM, CONS, BREATH NORM... C/O HEADACHE, DIZZY, NO NAUSEA OR VOMI T .. HAS BEEN INSIDE SINCE 0830 THIS AM. * *ONLY 4 TOTAL PTS AT TTHIS TIME** OTHER CUSTS HAD COMPLAINED OF ODOR PRIOR TO LE AVING, NO OTHER KNOWN PTS. E51 , WILL ADV ON AMBS D/14R2 , NO AMBS REQUESTED AT THIS TIME , HAVE 4 EMPL'S, HAVE BEEN HERE ALL DAY, SOME SYMPTOMS, E51 DOES NOT DETECT ANY ODOR, E52 TO BRING IN MICROMAX ASSTOS B5'1 MISC E5111 *AVL 'B51 MISC E51 MOBINS B51 OLIS E51,1 CLEAR E52 MOBINS E51 CLOSE E511 i,, , SOURCE IS HIGH:CARBON MONOXIDE, 300 PP M AROUND FURt,ZACE, 40 PPM 'INS POST OFC, E VAC NOW [225 ANDOVER PK W ,TUK] '#TF1108 EWING, D' AVE ATTEMPTING;TO SHUT OFF THE FURNACE NOW , BLDG IS EVAC, NOW VENTILATING D/14R2