Loading...
HomeMy WebLinkAboutHAZMAT 08-4253 - 4424 S 188TH ST - HAZMAT RELEASE INVESTIGATION W/ NO HAZMAT ON 11/6/20084424 S 188TH ST HAZMAT RELEASE INVESTIGATION W/ NO HAZMAT HAZMAT # 08-4253 Incident Report 2008-0804253 -000 40-L53 Tukwila Fire Department Page: 1 Printed: 11/06/2008 21:42:04 Basic Alarm Date and Time Arrival Time Controlled Date and Time Last Unit Cleared Date and Time Response Time Priority Response Completed Fire Department Station Shift Incident Type Initial Dispatch Code Aid Given or Received Mutual Aid Department Their Incident Number Alarms Action Taken 1 Apparatus - Suppression Personnel - Suppression Personnel Property Use Location Type Address City, State Zip District Census Tract Directions 14:29:17 Thursday, November 6, 2008 14:29:30 15:39:25 Thursday, November 6, 2008 0:00:13 Yes Yes 51 A 671 - Hazmat release investigation w/ no hazmat HZINV 4 - Automatic aid given 17M20 0803713 1 81 - Incident command 1 1 215 - High school/junior high school/middle school Address 4424 S 188 ST SeaTac, WA 98188 O/J 0284.03 4424 S 188 ST #200 ,SEA Person Involved - B51, Involvement Code Last Name Street Address REP B51 Apparatus - B51 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 B51 0:00:05 14:29:30 Thursday, November 6, 2008 14:29:25 Thursday, November 6, 2008 14:29:30 Thursday, November 6, 2008 15:39:25 Thursday, November 6, 2008 Yes 1 1 81 - Incident command 920 - Battalion Chief TF1144 - Mael, Charles Position: CAPT Personnel Action Taken 1: 81 - Incident command O� Authority Page: 1 Printed: 11/06/2008 21:42:04 Incident Report 2008-0804253 -000 Tukwila Fire Department Reported By igfc1-4-i Officer In Charge,iet Reviewer Authority TF1144 - Mael, Charles 21:39:21 Thursday, November 6, 2008 TF1144 - Mael, Charles 21:39:22 Thursday, November 6, 2008 Narratives Narrative Name Narrative Type Author Narrative Text CAD Narrative CAD Narrative CAD Incident Number: IF08003240 Cross Ref Inc#s for each Jurisdiction Involved: #1={ #2={IF08003239} Updated addl location info: -- TYEE HIGH SCHOOL Short Report: DOING HAZMAT SIDE OF CALL B51<14:29:49>, HOLDING OFF ON ADDTL RESOURCES AT THIS TIME, ON FIRE 5 B51<14:32:54>, REQ HM777 FROM POS <14:35:59>, 34 PTS, STILL NOT NEEDING TRANSPORT AT THIS TIME B51<14:36:32>,LT HOWELL/OPERATIONS PSH777<14:58:36>, ENTERING BLDG IN 10 SECONDS W/1 APD, 2 PORT AFT DETECTORS B51<15:08:31>, OPEN OUTSIDE DOOR IF MONITORING IS CLEAR PSH777<15:10:24>, CLEAR/OUT OF THE BLDG PSA786<15:24:48>, NO ODOR/IRRITANT FOUND IN 200 BLDG, NOW ASSISTING ENRTY TEAM B AT BLDG 700 B51<15:29:07>, ALL BLDGS CLEAR, NO HAZARDS FOUND, ALL PERSONNEL ARE OUT, TERMINATING CMD B51<15:29:54>, BACK TO FIRE 4 Narrative Name 0804253 Narrative Type Incident Narrative Date 20:10:30 Thursday, November 6, 2008 Author TF1144 - Mael, Charles Author Rank CAPT Author Assignment 1 Narrative Text At 1401 hrs Seatac Fire was dispatched to an aid call possibly involving some kind of hazardous spill at Tyee High School in building #200. Students and a few staff members called 911 to complain of irritating symptoms. B45 was command and reported up to 35 green patients. B51 was added to the call to handle the investigation of a possible hazardous materials release that caused the symptoms. On arrival B51 tied in with B45 for the incident action plan and current conditions. B45 stated that King County Sheriff Officers and many Seatac Page: 2 Printed: 11/06/2008 21:42:04 Incident Report 2008-0804253 -000 Tukwila Fire Department Narratives Firefighters had been inside building #200 and reported no odor or irritating side effects. B51 then assured that all personnel were out of the incident building #200 and it was secured from entry. A request was made by B51 to B45 to operate under the original call and create a Haz-Mat Group or Branch. B45 again requested that a separate incident be created for the Haz-Mat part of the original call. B45 created a second incident and B51 established 188st. Command. Lt. Howell from the Port of Seattle who is a Hazardous Materials Technician was made Operations for this incident. The Port of Seattle hazardous materials unit 777 was brought to the scene with 3 additional technicians and 1 operations level member. B51 interviewed the school teacher of the science lab to determine if any chemicals from her room could be involved. She stated all chemicals were secure and none of them could be the problem. The original odor came from the common hall running outside her classroom, not in it. E712 with a 4 person team, 2 as entry & 2 as back-up with full PPE & SCBA entered building #200 to recon and monitor the atmosphere. They were instructed to also look for any suspicious items that could have caused the odor. An APD 2000 and two AFT 4 gas detectors were used during the recon. They were instructed by Command if at any time they had a positive reading or found something of suspicion, they would pull out of the building and a full hazardous materials response would be initiated. All monitoring showed zero readings and no suspicious items could be found. All locked rooms & closets were unlocked and checked by the recon team. No positive fmdings of any type or hazard could be found. Building #200 was then ventilated by using natural horizontal ventilation through the outside doors and main hall. B51 reported the building clear and tied in with B45. B51 turned the fmdings of recon over to B45 and released the scene back to B45. B51 terminated 188th command and returned to Tukwila. End of Report Page: 3 Printed: 11/06/2008 21:42:04 Incident History for:#IF08003240 CN: $1F08003713 Xref:#IF08003239 Received 11/06/08 14:29:17 BY FD24 /BLASMI Entered 11/06/08 14:29:17 BY FD24 /BLASMI Dispatched 11/06/08 14:29:30 BY FD24 /BLASMI Enroute 11/06/08 14:29:30 Onscene 11/06/08 14:29:30 Closed 11/06/08 15:39:25 Initial Type:HZINV Final Type:HZINV : 1 Police 999999 Fire Police Rms: 4r (1")-3 TG: Initial Alarm Level:1 (HAZ MATERIAL INVESTIGATION)Pri:2Dispo: Alrm Lev IF1164 Grp:I6Beat: Lt/Lg: Fire Rms: Medic Rms: KC1164 Loc:4424 S 188 ST #200 ,SEA -- TYEE HIGH SCHOOL (V) Name:B51 Addr: 14:29:17 BLASMI FD24 ENTRY 14:29:17 FD24 $ASNCAS 14:29:30 FD24 DISPOS 14:29:30 FD24 ASNCAS 14:29:34 VC3690 FD23 CONTRL 14:29:49 BLASMI FD24 MISC 14:30:03 VC7948 FD25 CONTRL 14:30:09 BLASMI FD24 CROSS 14:32:54 FD24 MISC 14:34:44 VC7948 FD25 ASSTER 14:34:53 BLASMI FD24 14:35:14 FD24 14:35:59 FD24 14:36:04 14:36:08 14:36:32 14:36:46 14:44:21 14:48:59 VC7948 BLASMI VC7948 Phone: DOING HAZMAT SIDE OF CALL $IF08003713 B51 #TF1144 MAEL, CHUCK R51 TEAM LDR B51 $TF08004253 GRP: I9 ---> I7. B51 , HOLDING OFF ON ADDTL RESOURCES AT THIS TIME, ON FIRE 5 GRP: I7 - --> I6. #IF08003239 B51 , REQ HM777 FROM POS PSH777 [4424 S 188 ST #200 ,SEA] #PSH777 PORT H AZMAT 777 (433-5380) •, ,PORT ADVISED FOR HM AND WILL RLSPOND ON FIRE5 [188 CMD/SAME P/L] [188 CMD/SAME P/L] , 34 PTS, STILL NOT NEEDING TRANSPORT AT THIS TIME [4424 S 188 ST #200 ,SEA] NEWLOC B51 ASSTOS PSA786 MISC FD24 NEWLOC PSA786 FD24 ONSCNE PSA786 FD25 MISC B51 FD25 NEWLOC PSA786 FD24 ONSCNE PSH777 FD25 CHANGE 14:52:24 BLASMI FD24 14:52:30 FD24 14:52:33 FD24 14:58:36 FD24 15:08:31 ASSTOS PSE712 NEWLOC PSE712 ONSCNE PSE712 MISC PSH777 FD24 MISC B51 ,LT HOWELL/OPERATIONS [OPERATIONS] TG: - --> F5. [188 CMD/SAME P/L] [4424 S 188 ST #200 ,SEA] , ENTERING BLDG IN 10 SECONDS W/1 APD, 2 PORT AFT DETECTORS , OPEN OUTSIDE DOOR IF MONITORING IS CLE AR 15:10:24 FD24 MISC PSH777 , CLEAR/OUT OF THE BLDG 1,1:24:48 VC1675 FD24 MISC PSA786 , NO ODOR/IRRITANT FOUND IN 200 BLDG, NO W ASSISTING ENRTY TEAM .B AT BLDG 700 15:29:07 FD24 MISC B51 , ALL BLDGS CLEAR, NO HAZARDS FOUND, ALL PERSONNEL ARE OUT, TERMINATING CMD 15:29:13 FD24 CONTCT B51 15:29:54 FD24 MISC B51 , BACK TO FIRE 4 15:30:46 BLASMI FD24 CHANGE TG: F5 ---> F4. 15:34:56 FD24 OLIS B51 15:36:31 FD24 CLEAR PSA786 15:36:31 FD24 $CLEAR PSE712 15:36:35 FD24 CLEAR PSH777 15:39:25 FD24 MOBINS B51 15:39:25 FD24 CLOSE B51