HomeMy WebLinkAboutHAZMAT 12-1999 - 3600 SOUTHCENTER MALL - GAS LEAK (NATURAL GAS OR LPG) ON 6/5/20123600 SOUTHCENTER MALL GAS LEAK (NATURAL GAS OR LPG) HAZMAT # 12-1999 Incident Report 2012-1201999 -000 Tukwila Fire Department Page: 1 Printed: 06/05/2012 22:29:56 Basic Alarm Date and Time Arrival Time Controlled Date and Time Last Unit Cleared Date and Time Response Time Priority Response Completed Fire Department Station Shift Incident Type Initial Dispatch Code Aid Given or Received Mutual Aid Department Alarms Action Taken 1 Casualties Apparatus - Suppression Personnel - Suppression Personnel Hazardous Material Released Property Use Location Type Address City, State Zip District Census Tract Directions 23:31:08 Monday, June 4, 2012 23:37:55 00:05:30 Tuesday, June 5, 2012 0:06:47 Yes Yes 51 C 412 - Gas leak (natural gas or LPG) NGASXT 2 - Automatic aid received 17M14 1 85 - Enforce code No 8 11 1 - Natural gas - slow leak, no evacuation or hazmat actions 580 - General retail, other Address 3600 Southcenter MALL Tukwila, WA 98188 004 0262.00 3600 SOUTHCENTER ML ,TUK Person Involved - EMP/MILLER,MELISSA, Involvement Code Last Name Street Address Phone REP EMP/MILLER,MELISSA AMC SOUTHCENTER 16 2062140185 Apparatus - B13 Apparatus ID Apparatus Dispatch Date and Time En route to scene date and time Apparatus priority response Apparatus cancelled after dispatch Apparatus Use Apparatus Action Taken 1 Apparatus Type B13 23:39:25 Monday, June 4, 2012 23:39:26 Monday, June 4, 2012 Yes Yes 1 93 - Cancelled en route 920 - Battalion Chief Apparatus - B51 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time B51 0:03:42 23:34:13 Monday, June 4, 2012 23:34:13 Monday, June 4, 2012 Page: 1 Printed: 06/05/2012 22:29:56 t Incident Report 2012-1201999 -000 Tukwila Fire Department Apparatus - B51 Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 23:37:55 Monday, June 4, 2012 00:00:17 Tuesday, June 5, 2012 Yes 1 1 81 - Incident command 920 - Battalion Chief TF 1122 - Peterson, Lavern Position: BC Apparatus - E52 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 Personnel 3 E52 0:04:17 23:32:46 23:35:04 23:39:21 00:00:17 Yes 3 1 86 - Investigate 11 - Engine TF 1171 - Custer, Kory Position: FFI TF 1161 - Woolley, Charles Position: FFI TF1166 - Butler, Wesley Position: FFI Monday, June 4, 2012 Monday, June 4, 2012 Monday, June 4, 2012 Tuesday, June 5, 2012 Apparatus - L54 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 Personnel 3 Personnel 4 L54 0:05:28 23:32:46 23:34:36 23:40:04 23:50:17 Yes 4 1 324 - Fire Standby 13 - Quint TF 1114 - Konieczka, Jason Position: CAPT TF1155 - Karwhite, Jason Position: FFI TF2034 - Kelch, Joshua Position: FFI TF1156 - Williams, Ben Monday, June 4, 2012 Monday, June 4, 2012 Monday, June 4, 2012 Monday, June 4, 2012 Page: 2 Printed: 06/05/2012 22:29:56 Incident Report 2012-1201999 -000 Tukwila Fire Department Page: 3 Printed: 06/05/2012 22:29:57 Apparatus - L54 Position: FFI Apparatus - E14 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Use Apparatus Action Taken 1 Apparatus Type E14 0:08:07 23:32:46 Monday, June 4, 2012 23:35:08 Monday, June 4, 2012 23:43:15 Monday, June 4, 2012 23:45:09 Monday, June 4, 2012 Yes 1 324 - Fire Standby 11 - Engine Apparatus - A13 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Use Apparatus Action Taken 1 Apparatus Type A 13 0:08:04 23:32:46 Monday, June 4, 2012 23:35:13 Monday, June 4, 2012 23:43:17 Monday, June 4, 2012 23:45:07 Monday, June 4, 2012 Yes 1 324 - Fire Standby 75 - BLS/Aid unit Apparatus - B13 Apparatus ID Apparatus Dispatch Date and Time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Apparatus Use Apparatus Action Taken 1 Apparatus Type B13 23:36:55 Monday, June 4, 2012 23:45:24 Monday, June 4, 2012 23:45:24 Monday, June 4, 2012 Yes 1 324 - Fire Standby 920 - Battalion Chief Apparatus - E51 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Action Taken 2 E51 0:10:22 23:32:46 Monday, June 4, 2012 23:35:39 Monday, June 4, 2012 23:46:01 Monday, June 4, 2012 00:05:30 Tuesday, June 5, 2012 Yes 3 1 86 - Investigate 85 - Enforce code Page: 3 Printed: 06/05/2012 22:29:57 Incident Report 2012-1201999 -000 Tukwila Fire Depcu tment Cross Ref Inc#s for each Jurisdiction Involved: #1={TP12013161 Updated addl location info: -- AMC THEATERS Short Report: SMELL OF NATURAL GAS ON TOP FLOOR OF MALL. RP FELT LIGHT HEADED. <23:34:39>NAM: EMP/MILLER,MELISSA CON: 0 TXT: RP TRIED TO CONTACT SECURITY, BUT THEY'RE NOT ANSWERING RADIO CHECKS. RP IS EMP AT THE THEATER, CAN SMELL IT WHEN SHE WALKS AROUND. NO KNOWN ILLNESSES. THEATER NOT EVACUATING, MALL IS CLOSED. B51<23:41:21>,E51 GOING IN FOR AIR MONITORING, SMELL BETWEEN 2/3 FLOOR B51<23:41:51>, TO E52 -COME PARK ON SIDE A/SOUTH SIDE L54<23:43:53>, MANPOWER TO CMD POST E51<23:44:19>, 1ST FLOOR , NOTHING SMELLED, NOTHING ON GAS MONITOR , GOING TO 2ND FLOG R NOW B51<23:44:32>, E52 COMING IN FOR AIR MONTORING E51<23:44:44>, CAN PROBABLY DOWNGRADE THIS CALL E52<23:47:02>,TO CMD -GAS STOVE STILL ON , PILOT LIGHT ON, ODOR OF NATRUAL GAS , WILL BE TURNING IT OFF. NAME OF BUSN UNREADABLE E52<23:47:30>,NO READINGS BUT CAN DEFINITLEY SMELL IT, SMALL FLAME ON ONE STILL BURNI NG E52<23:47:43>, MIDDLE ZONE? IN FOOD COURT E52<23:48:09>, SC15 E52<23:48:48>, THAI GO IS NAME OF BUSN E52<23:49:39>234939, VERY MILD ODOR, NO READINGS } Page: 4 Printed: 06/05/2012 22:29:57 Apparatus - E51 Apparatus Type Personnel 1 Personnel 2 Personnel 3 11 - Engine TF1139 - Borden, John Position: CAPT TF1107 - Nichols, Jeff Position: FFI TF1178 - Rees, Richard Position: FFI Authority Reported By Officer In Charge Reviewer TF1139 - Borden, John 08:33:34 Tuesday, June 5, 2012 TF1139 - Borden, John 08:33:35 Tuesday, June 5, 2012 - , Narratives Narrative Name Narrative Type Author Narrative Text CAD Narrative CAD Narrative - , CAD Incident Number: TF12001862 Cross Ref Inc#s for each Jurisdiction Involved: #1={TP12013161 Updated addl location info: -- AMC THEATERS Short Report: SMELL OF NATURAL GAS ON TOP FLOOR OF MALL. RP FELT LIGHT HEADED. <23:34:39>NAM: EMP/MILLER,MELISSA CON: 0 TXT: RP TRIED TO CONTACT SECURITY, BUT THEY'RE NOT ANSWERING RADIO CHECKS. RP IS EMP AT THE THEATER, CAN SMELL IT WHEN SHE WALKS AROUND. NO KNOWN ILLNESSES. THEATER NOT EVACUATING, MALL IS CLOSED. B51<23:41:21>,E51 GOING IN FOR AIR MONITORING, SMELL BETWEEN 2/3 FLOOR B51<23:41:51>, TO E52 -COME PARK ON SIDE A/SOUTH SIDE L54<23:43:53>, MANPOWER TO CMD POST E51<23:44:19>, 1ST FLOOR , NOTHING SMELLED, NOTHING ON GAS MONITOR , GOING TO 2ND FLOG R NOW B51<23:44:32>, E52 COMING IN FOR AIR MONTORING E51<23:44:44>, CAN PROBABLY DOWNGRADE THIS CALL E52<23:47:02>,TO CMD -GAS STOVE STILL ON , PILOT LIGHT ON, ODOR OF NATRUAL GAS , WILL BE TURNING IT OFF. NAME OF BUSN UNREADABLE E52<23:47:30>,NO READINGS BUT CAN DEFINITLEY SMELL IT, SMALL FLAME ON ONE STILL BURNI NG E52<23:47:43>, MIDDLE ZONE? IN FOOD COURT E52<23:48:09>, SC15 E52<23:48:48>, THAI GO IS NAME OF BUSN E52<23:49:39>234939, VERY MILD ODOR, NO READINGS } Page: 4 Printed: 06/05/2012 22:29:57 Incident Report 2012-1201999 -000 Tukwila Fire Department Narratives Narrative Name Narrative Type Narrative Date Author Author Rank Author Assignment Narrative Text 1201999 Incident 07:28:17 Tuesday, June 5, 2012 TF1139 - Borden, John CAPT 1 At 2331 hours on Monday June 4, 2012 we were dispatched to a gas leak. Eight units were assigned to this incident. Eleven personnel responded. We arrived on scene at 2337 hours and cleared at 0005 hours. The incident occurred at 3600 Southcenter Mall, Tukwila in District 004. The local station is 51. The general description of this property is general retail. The primary task(s) performed at the scene by responding personnel was code enforcement. Automatic aid was received on this incident. Alarm number 1201999 has been assigned to this incident. Multiple Tukwila and Renton FD units were dispatched to the smell of natural gas in the SC Mall. Valley Comm told incoming units that the Mall was not evacuating, and that there were no medical symptoms from the gas leak. B51 arrived and established "Mall Command." E51 arrived and investigated. E52 arrived and assisted with air monitoring. E51 checked all of the areas (escalators between floors 2 & 3, and the AMC theater lobby) that the reporting party had said smelled like natural gas, and E51 smelled nothing and got no readings on the gas detector. E52 found a natural gas cooktop at "Thai Go" restaurant, in the 2nd floor Food Court. E52 shut off a gas valve at the cooktop, but the single pilot light that was lit did not go out. At the cooktop, the smell was almost undetectible. E51 tied in with Mall Security, telling them to contact the business owner to fix the problem, and for Security to walk by the occupancy on an hourly basis and to call 911 if the odor seriously worsened. TFD and RFD units returned in service. End of Report Page: 5 Printed: 06/05/2012 22:29:57 Incident History for:#TF120 Received 06/04/12 Entered 06/04/12 Dispatched 06/04/12 Enroute 06/04/12 Onscene 06/04/12 Closed 06/05/12 01862 CN: $TF12001999 Xref:#TP12013161 23:31:08 BY CR04 /VC3259 23:32:43 BY CR04 /VC3259 23:32:46 BY FD23 /VC4738 23:34:13 23:37:55 00:05:30 Initial Type:NGASIN TG: Initial Alarm Level:1 Final Type:NGASIN (NATURAL GAS LEAK INSIDE (2A))Pri:EDispo: ev: 1 Police TP600 Fire TF016M Grp:T7Beat: Lt/Lg: Police Rms: Fire Rms: Medic Rms: KC1016 Loc:3600 SOUTHCENTER ML ,TUK -- AMC THEATERS (V) Name:EMP/MILLER,MELISSA Addr:AMC SOUTHCENTER 16 Phone:2062140185 Contact:O Akvigct.ct Alrm L 23:32:43 23:32:43 23:32:46 23:32:46 23:32:46 23:32:46 23:32:46 23:32:46 23:32:46 23:32:46 23:32:46 23:33:24 23:33:34 23:33:38 VC3259 CR04 ENTRY SMELL OF NATURAL GAS ON TOP FLOOR OF MAL L. RP FELT LIGHT HEADED. $TF12001999 DISP E51 #TF1139 BORDEN, JOHN #TF1107 NICHOLS, JEFF #TF1178 REES, RICHARD C/F3 ASST E52 #TF1171 CUSTER, KORY #TF1161 WOOLLEY, CHUCK #TF1166 BUTLER, WES C/F3 ASST E14 #RF0212 ARENDS, DAVID #RF0237 NEVEGOLD, CHARLIE #RF0250 OLIN, JARED C/F3 ASNCAS E14 $RF12005689 ASST A13 #RF0163 CANTRELL, ELEANOR #RF0227 PLUMLEE, ANDREW C/F3 ASST L54 #TF1114 KONIECZKA, J. HM TEAM LDR #TF1155 KARWHITE, JASON #TF2034 KELCH, JOSHUA #TF1156 WILLIAMS, BEN C/F3 #TFINFO TUKWILA CHIEF INFO PAGER C/F3 #XF0001 TUKWILA FIRE BC INFO PAGE CR04 $ASNCAS VC4738 FD23 FD23 FD23 FD23 FD23 FD23 FD23 ASST TFINFO FD23 ASST TFBC FD23 ASNCAS TFBC FD23 CONTRL FD23 CLEAR TFINFO FD23 CLEAR TFBC C/F3 $XF12020534 GRP: T9 ---> T7. 23:34:13 FD23 23,:34:36 TF1114 L54 23:34:39 VC3259 CRO4 ASSTER B51 #TF1122 PETERSON, LAVERN *ENROUT L54 SUPP NAM: EMP/MILLER,MELISSA CON: 0 TXT: RP TRIED TO CONTACT SECURITY, BUT T HEY'RE NOT ANSWERING RADIO CHECKS. RP I EMP AT THE THEATER, CAN SMELL IT WHEN HE WALKS AROUND. NO KNOWN ILLNESSES. TH ATER NOT EVACUATING, MALL IS CLOSED.. 23:35:04 TF1171 E52 *ENROUT E52 23:35:08 RF0212 E14 *ENROUT E14 23:35:13 RF0163 A13 *ENROUT A13 23:35:39 TF1139 E51 *ENROUT E51 23:36:55 VC4738 FD23 ASSTER B13 23:37:55 FD23 ONSCNE B51 23:38:02 FD23 NEWLOC B51 23:38:30 FD23 NEWLOC E51 23:38:43 FD23 ASSTOS CMDF 23:39:14 FD23 PREMPT B13 23:39:21 FD23 ONSCNE E52 23:39:25 FD23 ASSTER B13 23:40:04 TF1114 L54 *ONSCNE L54 23:41:21 VC4738 FD23 MISC B51 23:41:51 FD23 MISC B51 23:42:04 VC3247 PD33 $CROSS 23:43:15 VC4738 FD23 ONSCNE E14 23:43:17 FD23 ONSCNE A13 23:43:53 FD23 MISC L54 23:44:19 FD23 MISC E51 23:44:32 FD23 MISC B51 23:44:44 FD23 MISC E51 23:45:07 FD23 MOBINS A13 23:45:09 FD23 MOBINS E14 23:45:24 FD23 MOBINS B13 23:45:59 FD23 NEWLOC E51 23:46:01 FD23 ONSCNE E51 23:47:02 FD23 MISC E52 23:47:30 FD23 MISC E52 23:47:43 FD23 MISC E52 23:48:09 FD23 MISC E52 23:48:48 FD23 MISC E52 23:49:39 FD23 MISC E52 [3600 SOUTHCENTER ML ,TUK] #RF0083 HETTI CK, JOHN ,VERY LRG MALL COMPLEX 2 ST , SOUTH SIDE /SIDE A, MALL CMD, CMD IS AT MY RIG [MALL CMD ] [SIDE A ] [SIDE A ] #XF0000 COMMAND POST LOCATION [3600 SOUTHCENTER ML ,TUK] #RF0083 HETTI CK, JOHN ,E51 GOING IN FOR AIR MONITORING, SMELL BETWEEN 2/3 FLOOR , TO E52 -COME PARK ON SIDE A/SOUTH SIDE #TP12013161 , MANPOWER TO CMD POST , 1ST FLOOR , NOTHING SMELLED, NOTHING 0 N GAS MONITOR , GOING TO 2ND FLOO R NOW , E52 COMING IN FOR AIR MONTORING , CAN PROBABLY DOWNGRADE THIS CALL [3600 SOUTHCENTER ML ,TUK] ,TO CMD -GAS STOVE STILL ON , PILOT LIGHT ON, ODOR OF NATRUAL GAS , WILL BE TURN NG IT OFF. NAME OF BUSN UNREADABLE ,NO READINGS BUT CAN DEFINITLEY SMELL IT , SMALL FLAME ON ONE STILL BURNI NG , MIDDLE ZONE? IN FOOD COURT , SC15 , THAI GO IS NAME OF BUSN , VERY MILD ODOR, NO READINGS 23:50:17 FD23 MOBINS L54 OOr.00:11 VC5055 FD23 CONTCT E51 , IN CONTACT W/MALL SEC 00:00:17 FD23 CLEAR B51 00:00:17 FD23 CLEAR E52 00:00:20 FD23 CLEAR CMDF 00:05:30 TF1139 E51 MOBINS E51 00:05:30 E51 CLOSE E51