HomeMy WebLinkAboutHAZMAT 14-0423 - 5155 S 160TH ST - GAS LEAK ON 2/3/20145155 S 160TH ST GAS LEAK HAZMAT # 14-0423 Incident Report 2014-1400423 -000 Tukwila Fire Department 11-- ol-a3 Page: 1 Printed: 02/04/2014 09:32:41 Basic Alarm Date and Time Arrival Time Controlled Date and Time Last Unit Cleared Date and Time Response Time Priority Response Completed Fire Department Station Shift Incident Type Initial Dispatch Code Aid Given or Received Alarms Action Taken 1 Action Taken 2 Action Taken 3 Casualties Apparatus - Suppression Personnel - Suppression Personnel Hazardous Material Released Property Use Location Type Address City, State Zip District Census Tract Directions 22:03:46 Monday, February 3, 2014 22:13:11 23:15:42 Monday, February 3, 2014 0:09:25 Yes Yes 51 A 412 - Gas leak (natural gas or LPG) NGASXT N - None 1 42 - Hazmat detection, monitoring, sampling, & analysis 45 - Remove hazard 51 - Ventilate No 3 7 0 - Special hazmat actions required or spill >= 55 gallons 419 - 1 or 2 family dwelling Address 5155 S 160 ST Tukwila, WA 98188 004 0282.00 5155 S 160 ST ,TUK Person Involved - CAPTAIN MCFARLAND, Involvement Code Last Name Street Address Phone REP CAPTAIN MCFARLAND 444 ANDOVER PARK E 2069718710 Hazmat Population Density Area Affected Area Affected Unites Cause of Release Disposition 2 - Suburban - Predominantly single family residential 2 - Blocks 1 1 - Intentional 2 - Completed with fire service present O� Hazmat Chemicals Chemical Name Hazardous Material Apparatus - L54 Apparatus ID Apparatus Dispatch Date and Time L54 22:05:41 Monday, February 3, 2014 Page: 1 Printed: 02/04/2014 09:32:41 Incident Report 2014-1400423 -000 Tukwila Fire Department Apparatus - L54 En route to scene date and time Apparatus Clear Date and Time Apparatus priority response Apparatus cancelled after dispatch Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Type Personnel 1 Personnel 2 Personnel 3 22:06:30 Monday, February 3, 2014 22:06:30 Monday, February 3, 2014 Yes Yes 3 1 93 - Cancelled en route 13 - Quint TF 1121 - Hayman, Ben Position: CAPT TF1179 - Willis, Brian Position: FFI TF1162 - Rodal, William Position: CAPT Apparatus - E51 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 Apparatus Action Taken 2 Apparatus Action Taken 3 Apparatus Type Personnel 1 Personnel 2 Personnel 3 E51 0:07:25 22:05:41 Monday, February 3, 2014 22:05:46 Monday, February 3, 2014 22:13:11 Monday, February 3, 2014 23:15:42 Monday, February 3, 2014 Yes 3 1 42 - Hazmat detection, monitoring, sampling, & analysis 45 - Remove hazard 51 - Ventilate 11 - Engine TF 1119 - McFarland, Loren Position: CAPT TF 1106 - Johnson, Aaron Position: FFI TF 1168 - Hickey, Matt Position: FFI Apparatus - B51 Apparatus ID Response Time Apparatus Dispatch Date and Time En route to scene date and time Apparatus Arrival Date and Time Apparatus Clear Date and Time Apparatus priority response Number of People Apparatus Use Apparatus Action Taken 1 B51 0:06:48 22:07:55 Monday, February 3, 2014 22:07:55 Monday, February 3, 2014 22:14:43 Monday, February 3, 2014 22:37:02 Monday, February 3, 2014 Yes 1 1 81 - Incident command Page: 2 Printed: 02/04/2014 09:32:41 Incident Report 2014-1400423 -000 Tukwila Fire Department s Ref Apparatus - B51 Apparatus Type Personnel 1 920 - Battalion Chief TF 1137 - Reed, Ken Position: CAPT Authority Reported By Officer In Charge Reviewer TF 1119 - McFarland, 09:32:11 Tues.- TF 113 7 - Ree • Ken 09:32:17 uesday,i • 0) 4, Loren February eb 4, 2014 4 Narratives Narrative Name Narrative Type Author Narrative Text CAD Narrative CAD Narrative _ CAD Incident Number: TF14000381 e••• II for each Junsdictton Involved: #1={TP14002740 Updated addl location info: 53 AV S/S 160 near SLADE WY Short Report: TPD RELAYED TO RP SMELL OF NAT GAS IN AREA. E51<22:15:09>,NEED PSE GAS, 52/S 160 E51<22:15:58>,PSE GAS ADVISED, ETA 20-30 MINS E51<22:19:24>, VACANT STRUCTURE B51<22:31:49>, PSE GAS UPDATED E51<22:40:31>, FOUND THE BACK DOOR OPEN AND OPEN DOORS/WINDOWS, READING IS BELOW 10 PP M } Narrative Name 1400423 Narrative Type Incident Narrative Date 09:23:45 Tuesday, February 4, 2014 Author TF 1119 - McFarland, Loren Author Rank CAPT Author Assignment 1 Narrative Text At 2203 hours on Monday February 3, 2014 we were dispatched to a gas leak. Three units were assigned to this incident. Seven personnel responded. We arrived on scene at 2213 hours and cleared at 2315 hours. The incident occurred at 5155 S 160 St, Tukwila in District 004. The local station is 51. The general description of this property is 1 or 2 family dwelling. The primary task(s) performed at the scene by responding personnel were material detection, monitoring, sampling, and analysis. Other special haz mat actions were also taken. No mutual/automatic aid was given or received. Alarm number 1400423 has been assigned to this incident. Page: 3 Printed: 02/04/2014 09:32:41 Incident Report 2014-1400423 -000 Tukwila Fire Department Narratives TPD officer came into Sta 51 to report odor of natural gas in the area of 53 Av S and S 160 St. He stated that the odor seemed to be persistent and maybe we should check it out. E-51 and B-51 responded and found definite odor in the area. Search led us to 5155 S 160 St. This is a vacant bank repo house. Monitor at the front door bottom edge immediately set the gas monitor off in alarm. Went to the gas meter and found it to be mostly shut off but not fully and it was flowing. TPD found the back door of the house to be wide open. PSE was called for. After ten minutes we were able to open windows and doors and get natural ventilation going. Found gas valve in the living room to be open with no appliance hooked up. This house is vacant and some remodeling has been started at some point but no work appears to being taken recently. After about 30minutes PSE rep arrived. The house was now well ventilated. He locked out the meter and checked for leaks there. He capped off the inside line and we were all done. House was secured. E-51/ B-51 in service- returning. End of Report Page: 4 Printed: 02/04/2014 09:32:41 Incident History for:#TF14000381 CN: $TF14000423 Xref:#TP14002740 Received 02/03/14 22:03:46 BY CR10 N01306 Entered 02/03/14 22:05:36 BY CR10 N01306 Dispatched 02/03/14 22:05:41 BY FD23 /VC5014 Enroute 02/03/14 22:05:46 Onscene 02/03/14 22:13:11 Closed 02/03/14 23:15:42 Initial Type:NGASXT TG: Initial Alarm Level:1 Final Type:NGASXT (NATURAL GAS LEAK OUTSIDE (5A))Pri:1 Dispo: Alrm Lev: 1 Police TP500 Fire TF015W Grp:T7Beat: Lt/Lg:00000000000/00000000000 Police Rms: Fire Rms: Medic Rms: KC1015 Loc:5155 S 160 ST ,TUK near SLADE WY (V) Add'I Loc Info:53 AV S/S 160 Name:CAPTAIN MCFARLAND Addr:444 ANDOVER PARK E Phone:2069718710 tqr-ov's 22:05:36 V01306 CR10 ENTRY TPD RELAYED TO RP SMELL OF NAT GAS IN AR EA. 22:05:36 CR10 $ASNCAS $TF14000423 22:05:41 VC5014 FD23 DISP E51 #TF1119 MCFARLAND, LOREN #TF1106 JOHNSON, AARON #TF0051 TFD E51 #TF1168 HICKEY, MATT C/F3 22:05:41 FD23 ASST L54 #TF1121 HAYMAN, BEN #TF1179 WILLIS, BRIAN #TF0054 TFD E54 #TF1162 RODAL, BILL C/F3 22:05:46 TF1119 E51 *ENROUT E51 22:06:01 VC5014 FD23 CONTRL GRP: T9 ---> T7. 22:06:30 FD23 CDGRN L54 ,L54 IS CODE GREENED FROM #TF14000381 - 16000 53 AV S ,TUK 22:07:26 FD23 IQIS L54 22:07:55 FD23 ASSTER B51 [16000 53 AVS ,TUK] #TF1137 REED, KEN 22:12:18 VC2706 PD33 CROSS #TP14002740 22:13:11 TF1119 E51 *ONSCNE E51 22:14:43 TF1137 B51 *ONSCNE B51 22:15:09 VC5014 FD23 MISC E51 ,NEED PSE GAS, 52/S 160 22:15:44 FD23 NEWLOC E51 [52/S 160 22:15:58 FD23 MISC E51 ,PSE GAS ADVISED, ETA 20-30 MINS 22:19:24 VC8378 FD23 MISC E51 , VACANT STRUCTURE 22:31:01 VC5014 FD23 CHANGE LOC: 16000 53 AV S ,TUK --> 5155 S 160 ST ,TUK 22:31:49 FD23 MISC B51 , PSE GAS UPDATED 22:37:02 TF1137 B51 MOBINS B51 22:40:31 VC5014 FD23 MISC E51 , FOUND THE BACK DOOR OPEN AND OPEN DOOR S/WINDOWS, READING IS BELOW 10 PP M 23:15:42 TF1119 E51 MOBINS E51 23:15:42 , E51 CLOSE E51