Loading...
HomeMy WebLinkAboutHAZMAT 89-1847 - 1200 MONSTER RD S - HZLEAK (HAZD CHEMICAL SPILL LEAK) ON 8/18/19891200 MONSTER RD S HZLEAK (HAZD CHEMICAL SPILL LEAK) HAZMAT # 89-1847 DATE: 08/19/89 TUKWILA FIRE DEPARTMENT WASHINGTON STATE FIRE INCIDENT REPORT OK FDID 1 INCIDENT EXP. 1 DATE 1 DAY 1 ALARM 1 ARRIVAL; IN NUMBER 1 NUMBER 1 1 OF WEEK 1 TIME 1 TIME 'SERVICE 17M19 1 891847 00 1 08/18/891 6 1 0813 1 0822 1 1123 TYPE OF SITUATION FOUND 47 1 ACTION TAKEN 5 1 MUTUAL AID 2 FIXED PROPERTY USE 648 1 IGNITION FACTOR 00 ADDRESS 1200 MONSTER RD S REN 98055 1 CENSUS TRACT 259 OCCUPANT NAME METRO SEWAGE TREATMENT PLANT 1 TELEPHONE 684-2400 1 ROOM OR APT. 1 NA OWNER NAME 1 ADDRESS KING COUNTY METRO 1 TELEPHONE 1 684-2400 METHOD OF ALARM 4 1 DISTRICT ONA 1 SHIFT A 1 ALARMS 1 NUMBER FIRE PERSONNEL 1 ENGINES 1 AERIAL APPARATUS 1 OTHER VEHICLES RESPONDED 002 1 000 { 000 1 001 NUMBER: INJURIES FIRE SERVICE 000 OTHER 000 1 FATALITIES 1 FIRE SERVICE 000 OTHER 000 COMPLEX 1 MOBILE PROPERTY TYPE AREA OF FIRE ORIGIN 1 EQUIPMENT INVOLVED FORM OF HEAT 1 TYPE OF MATERIAL 1 FORM OF MATERIAL METHOD OF EXTINGUISHMENT 1 LEVEL OF ORIGIN 1 LOSS 00 NUMBER OF STORIES 1 CONSTRUCTION TYPE EXTENT OF FLAME DAMAGE 1 EXTENT OF SMOKE DAMAGE DETECTOR PERFORMANCE 1 SPRINKLER PERFORMANCE Q IF SMOKE SPREAD BEYOND ROOM OF ORIGIN TYPE OF MATERIAL GENERATING SMOKE AVENUE OF SMOKE TRAVEL FORM OF MATERIAL GENERATING SMOKE IF MOBILE PROPERTY NA YEAR MAKE NA NA MODEL NA S/N NA LICENSE NUMBER NA T IF EQUIPMENT INVOLVED NA YEAR MAKE NA NA MODEL NA S/N NA OFFICE CHARGE A/LT R. L. BREWSTER MEMBER MAKING REPORT REPORT DATE A/LT R. L. BREWSTER 08/18/89 DATE: TUKWILA FIRE DEPARTMENT NARRATIVE SECTION INCIDENT NUMBER: 891847 HAZ/MAT 51 DISPATCHED TOA CHLORINE LEAK AT THE RENTON METRO TREATMENT PLANT. HAZ/MAT 51 ASSISTED RENTON FIRE DEPT WITH REMOVEING THE HAZARD. TWO FIREFIGHTERS - ONE HAZ/MAT UNIT - NO OTHER EQUIPMENT USED Incident History for: 4RF89003152 CN: $RF89003083 Entered 08/18/89 07:43:30 BY FD01 PAYNE Dispatched 08/18/89 07:43:37 BY FD01 PAYNE Enroute 08/18/89 07:44:30 Onscene 08/18/89 07:48:03 Closed 08/18/89 11:48:00 Initial Type: HZLEAK Initial Alae Level: 1 Final Tvpe: HZLEAK (HUD CHEMICAL SSPILL LEAK (1A)) Pri: 2 Disno: Alarm Le vel: 1 Police RP4242 Fire RF1916 8rouu: R9 Beat: Police Ris: Fire R,s: Medic Rms: Loc: 1200 MONSTER RD SW .REN -- METRO DISPOSAL PLT Name: GRENNETT. MR Addr: Phone: 226-3680 /0743 (PAYNE ) ENTRY CHLORINE BUILDING WIND FROM THE SOU /0743 $ASNCAS $RF89003033 /0743 DISP Ell 490045 53045 /0743 ASST L11 480032 50032 /0743 ASST All 490044 50044 /0743 ASST CMDII 480037 S1037 /0744 (;#####) ENROUT Ell /0744 ENROUT CMD11 /0744 ENROUT Lil /0744 ENROUT A11 /0746 (PAYNE ) MISC CMD11 CONFIRMED SMALL LEAK /0747 MISC THIS IS A SARA EMERGENCY RESPONSE PLAN /0748 (######) ONSCNE CMD11 /0748 ONSCNE Ell /0748 ONSCNE All /0748 (PAYNE ) MISC CMD11 , SECONDARY STAGING AT THE GATE ON SEVENTH /0749 (######) ONSCNE L11 /0749 (PAYNE ) MISC Ell .LET PEOPLE THRU THE ENTRANCE /0754 MISC LI1 . MOVING FORWARD AND WILL BE OPERATIOS /0754 ASST I116 [1200 MONSTER RD SW .REN] /0754 ONSCNE I116 /0758 MISC CMD11 . RESOURCE POOL DIRECTLY NORTH OF CMD11 /0758 MISC CMD11 . Ell 111 MOVE DIRECTLY NORTH OF CMD11 AND Ell R PT TO CMD11 /0759 MISC CMD11 . TWO AT SECONDARY STAGING /TWO MEMBER S OF THE HAZ MAT TEAM AND STAGING IS NOW DEPLETED /0801 MISC . HAZMAT 11 PROCEED TO THE LOCATION /0802 MISC HAZMAT 11 NOW RESPONDING /0802 MISC ONE MAN TO OPERATIOINS POOL FOR MEDICAL SECTOR /0303 MISC HAZMAT It COME IN OFF OF SEVENTH /0803 (SHAFFE) ASST HM11 [1200 MONSTER RD SW .REN) /0806 (PAYNE) MISC , WHEN HM1, ARRIVES GO TO 111 LOCATION /0806 ONSCNE HM11 /0812 MISC CMD1I . CALLING FOR MORE MANPOWER /0813 ASST HM54 [1200 MONSTER RD SW ,REN? /0813 ASNCAS HM54 STF89001882 /0815 ENROUT HM54 /0816 M1SC HM54 ENTER OFF OF SEVENTH AND OAKSDALE /0819 MISC . PERSONNEL COMING FROM STATION STAGE AT 7 AND 0 AKSDALE /0820 M1SC . NEED TWO PERSONNEL ±"-T HM1I AND MANPOWER POOL N OW DEPLETEE lRa7? f1NSI 4M54 /0826 MISC , CHI5 IN CHARGE OF MANPOWER POOL AND CMD11 NEED 5 A PORTABLE /0831 MISC . NOTIFIED E13 THAT THEY WERE ONLY UNIT AVAILABL E IN RENTONTHEY WILL BE MOVING TO STATION 11 /0847 MISC Eli , NOW WATER SUPPLY /0849 MISC CMD11 . RENTON FIRE WILL BE USING FIRE 3 FOR ENTRY /0849 MISC . NOTIFIED FIRE PREVENTION FOR BOTH RENTON AND T UK NOT TO USE FIRE /0850 ASST I514 [1200 MONSTER RD SW .RENT /0851 MISC 1514 . BRINGING ADDITIONAL PORTABLES /0854 MISC 1514 . REPORT TO STAGING NORTH END OFF OF PERIMETER A ND 7 AND OAKSDALE /0855 MISC 1514 . ETA OF 5 MINUTES /0856 ONSCNE 1514 /0900 M1SC CMD11 . OPERATIONS REPT TO THE COMMAND POST /0906 MISC CMD11 , WATER SUPPLY THEY ARE LAYING THE REVERSE NOW /0910 MISC Ell , FLOWING THE WATER NOW /0914 MISC Ell , REDUCE YOUR PRESSURE /0918 MISC . METRO PERSONNEL ON AIR AT 09 POINT /0918 MISC . CHANGING BOTTLES /0920 MISC . ENTRY TEAMS RADIOS ARE LOUD AND CLEAR /0922 MISC , SOMEONE WALKING THRU THE MAZE OF TANKS /0922 MISC . IF ANY PRODUCT DECONTAMINATE USING THE SHOWER AT THEFRT DOOR,} LINE 922 MISC . ENTRI.J TEAM ENTERING NOW AND LINE IS CHARGED /0923 MISC . VALVE ONE IS CLOSED /0924 MISC . TEAMS 1 AND 2 RETURN FOR BRIEFING /0924 MISC . NO CONCENTRATION Iy THE ROOM ENTRY TEAM WENT 1 N /0924 MISC , ENTRY TEAM 1 AND 2 OFF OF AIR /0923 MISC Ell BACKING THE PRESSURE DOWN NO LONGER NEEDED /0955 MISC . DROP PRESSURE ABOUT 20 Ell /0955 MISC , THREE MINUTES TO ENTRY /0956 MISC . ENTRY TEAM ONE IS READY /0957 MISC . HAVE ENGINE COMPANY MOVE THE HOSE LINE TO THE FRONT DOOR /0957 MISC . GOING IN NOW /1000 MORINS 1514 /1003 MISC . ENTRY TEAM OK /1004 MISC . OPEN UP BACK DOOR /1009 MISC . TEAM TWO CHECK. YOUR AIR PRESSURE /1011 MISC . METER NOW DOWN BELOW 100 READY IS NOW 86 /1012 MISC . 30 PARTS PER MILLION /1014 MISC .ENTRY TEAM OK /1018 MISC . CHECKNIG THE AIR QUALITY AGAIN /1019 MISC ENTRY TEAM 2 IS AT 25 ENTRY TEAM 1 AT 24 SOMEO NE REPORTED 40 PARTS PER MILLION /1020 MISC . ENTRY TEAM 3 NOW ENTERING, SHUT DOWN THE LINE WITH THE F06 /1020 MISC . METRO SUPERVISOR HAS NOW RESET WILL BE CHECKIN G /1023 MISC , ENTRY TEAM 3 HAVE FOUND NOTHING YET /1024 MISC . DOWN TO 32 PARTS PER MILLION /1025 MISC , SEQUENTIALLY CHECKED EACH EVAPORATOR /1031 MISC . 24 PARTS PER MILLIC'N /1037 MISC , VALVE HAS NOT BEEN RECLOSED/SUPERVISOR ENROUTE BACK OUT TO TALK WITH FIRE /1039 MISC . METRO READING ON TFE PUMP IS I3 PARTS PER MILL ION /1041 M1SC PULL THE ENTRY TEAMS OUT AND DECONTAMINTE LEAV E THE DOORS OPEN /1042 MISC . ATLEAST A ONE MINUTE DECONTAMINATION TIME /1042 MISC . TEAM NO 1 IN DECONTAMINATION NOW /1044 MISC . TWENTY S CndD5 MORE FOR ENTRY TEAM 2 /1119 OLIS HM11 /11r, WIPTWS NM94 /1127 (**U*4) I419 CMO11 /111.9 (PAYNE ) OLIS All /1129 LIS n. IS : it Ltt /1131 (MM) MOBINS All /1135 (PAYNE ) 1013 HM11 /1138 (MS13) MOBINS Ell /1141 MOBINS L11 /1148 (PAYNE ) MOBINS 1116 /1143 CLOSE Ell