Loading...
HomeMy WebLinkAboutHAZMAT 90-0708 - 4300 S 124TH ST - NGASXT (NATURAL GAS LEAK OUTSIDE) ON 3/20/19904300 S 124TH ST NGASXT (NATURAL GAS LEAK OUTSIDE) HAZMAT # 90-0708 DATE: 03/20/90 TUKWILA FIRE DEPARTMENT WASHINGTON STATE FIRE INCIDENT REPORT FDID 1 INCIDENT EXP. 1 DATE 1 DAY 1 ALARM 1 ARRIVAL: IN NUMBER 1 NUMBER 1 OF WEEK 1 TIME 1 TIME ;SERVICE A 17M19 1 900708 00 1 03/20/901 3 1 0146 1 0L52 1 0223 B TYPE OF SITUATION FOUND 41 1 ACTION TAKEN 5 1 MUTUAL AID 3 C FIXED PROPERTY USE 962 1 IGNITION FACTOR 00 D ADDRESS 4300 S 124 ST 98178 1 CENSUS TRACT 263 E OCCUPANT NAME 1 TELEPHONE ; ROOM OR APT. CITY STREET NA NA F OWNER NAME: NA 1 TELEPHONE ADDRESS: NA NA G METHOD OF ALARM 4 1 DISTRICT 007 1 SHIFT B 1 ALARMS 1 H NUMBER FIRE PERSONNEL 1 ENGINES 1 AERIAL APPARATUS 1 OTHER VEHICLES RESPONDED 004 1 001 1 000 1 001 I NUMBER: INJURIES FATALITIES FIRE SERVICE 000 OTHER 000 1 FIRE SERVICE 000 OTHER 000 J COMPLEX 1 MOBILE PROPERTY TYPE K AREA OF FIRE ORIGIN : EQUIPMENT INVOLVED L FORM OF HEAT : TYPE OF MATERIAL 1 FORM OF MATERIAL M METHOD OF EXTINGUISHMENT 1 LEVEL OF ORIGIN 1 LOSS 00 N NUMBER OF STORIES 1 CONSTRUCTION TYPE O EXTENT OF FLAME DAMAGE 1 EXTENT OF SMOKE DAMAGE P DETECTOR PERFORMANCE 1 SPRINKLER PERFORMANCE Q IF SMOKE SPREAD TYPE OF MATERIAL GENERATING SMOKE BEYOND ROOM OF AVENUE OF SMOKE TRAVEL R ORIGIN FORM OF MATERIAL GENERATING SMOKE S IF MOBILE PROPERTY YEAR MAKE NA NA NA SERIAL NUMBER: NA MODEL NA LICENSE NUMBER NA T IF EQUIPMENT INVOLVED NA SERIAL NUMBER: NA OFFICER IN CHARGE YEAR MAKE NA NA LT. LOREN J. MCFARLAND MODEL NA LT. LOREN J. AND EPORT DATE 90 DAT.E: TUKWILA FIRE DEPARTMENT NARRATIVE SECTION INCIDENT NUMBER: 900708 DISPATCHED TO REPORTED STRONG SMELL OF NATURAL GAS AND HISSING SOUND COMING FROM A PIPE. TUKWILA PD HAD SMELLED NATURAL GAS IN THE AREA AND LOCATED A PIPE THAT WAS HISSING. UPON ARRIVAL FOUND A VENT PIPE COMING UP FROM UNDER GROUND. THERE WAS A HISSING SOUND PRESENT AND THE SMELL OF NATURAL GAS IN THE AREA. FOUND A VAULT LID JUST OUT FROM THE PIPE AND LIFTED THE LID. INSIDE THERE WAS PIPING AND RELIEF VALVING. GAS COULD BE HEARD FLOWING FROM THE RELIEF VALVE AND OUT TO THE ABOVE GROUND VENT PIPE. FLOW WAS NOT FAST BUT A STEADY EASY FLOW. CALLED FOR A REP FROM WASHINGTON NATURAL GAS. UPON ARRIVAL SHOWED HIM WHAT WE HAD FOUND. NOW THE SYSTEM WAS NO LONGER VENTING. HE ADVISED THAT THE RELIEF VALVES GET STICKY AND START TO VENT IN THE DESCRIBED MANNER. WILL HAVE A CREW COME OUT AND CHECK THE SYSTEM TOMORROW. RETURNED. Incident History for: Received 83/28/98 Entered 83/28/98 Dispatched 83/28/98 Enroute 83/28/98 Onscene 83/28/98 Closed 83/28/98 Initial Type: N6ASXT Final Type: N6ASXT vel: 1 *TF98888688 CN: iTF98888788 81:46:43 BY FD81 SCHMID 81:46:43 BY FD81 SCHMID 81:46:48 BY FD81 SCHMID 81:49:11 81:52:85 82:23:53 Initial Alarm Level: 1 (NATURAL 6AS LEAK OUTSIDE (5A)) Pri: 1 Dispo: Alarm Le Police TP1488 Fire TF5348 Group: T9 Beat: P9lice Ras: Fire Res: Medic Res: oc: 12488 43 AV S ,TUK near UNK Name: 3T9 Addr: Phone: /8146 (SCHMID) ENTRY SOUTH SIDE OF ROAD, PIPE IN THE AIR, HISSING NDI SE, STRONG SMELL OF NAT 6 AS /8146 $ASNCAS $TF98888f101 046 DISP E53 /8146 ASST E52 /8146 ASST A53 /8149 ENROUT E53 /8149 ENROUT A53 /8149 IQIS E52 /8152 ONSCNE E53 /8152 ONSCNE A53 /8156 MISC E53 , CALLIN6 WA NAT 6AS /8158 MOBINS A53 /8158 MISC E53 . NN6 CO WILL BE CALLING BACK WITH AN ETA /8288 MISC E53 . 6AS CO ETA 18 MINUTES /8228 MISC E53 , WA NAT SAS ON LOCATION /8223 (HILL ) MOBINS E53 /8223 CLOSE E53 90 C706 L7 /V)t 14--44 A/ FF F F