Loading...
HomeMy WebLinkAboutHAZMAT 95-2984 - 350 MIDLAND DR - FLAMMABLE GAS OR LIQUID CONDITION (LEAK OR SPILL) ON 9/6/1995350 MIDLAND DR FLAMMABLE GAS OR LIQUID CONDITION, OTHER HAZMAT # 95-2984 TUKWILA FIRE DEPARTMENT FIRE INCIDENT REPORT - Sct FDID: 17M19 Date: 09/06/95 Dispatch: 1600 First Co: E51 Incident No: 95-002984-000 Multi -Agency: 17M19-95-002984 Arrival,: 1604 End: 1630 Days: 0 Response: 0 04 District: 006 Temperature: 065 (F) MUTUAL AID RECEIVED (By Contract) TELEPHONE TIE -LINE TO FIRE DEPARTMENT (911 sy. CLOUDY FLAMMABLE GAS OR LIQUID CONDITION (LEAK OR SP. SMOKE OR TOXIC GAS REMOVAL PRIVATE TAX -PAYING PROPERTY Aid: 1 Alarm Method:.7 Weather: 2 Situation(s): 41 Action(s) Taken: 16 Property Mangmnt: 1 Address/Location: 350 MIDLAND _DR. Room/Apartment: City/State: TUKWILA, WA Hazard Zone: Personnel Apparatus Aerial: 02 Paid: 0013 Engine: 002 Command: 02 General Use: 00 Specific Use: 000 Bldg Occupancy: 84 Struct. Status: 2 Occupied?: 1 Zip: 98188-0000 Census Tract: 0262.00 Volunteer: 0000 Truck: 00 Medical: 01 Other: 00 Tanker: 00 Rescue: 00 Hazmat: 00 GENERAL PROPERTY USE UNDET. OR NOT REPORTED SPECIFIC PROPERTY USE UNDET. OR NOT REPORTED FACTORIES, WORKSHOPS, STORAGE NON-COMBUSTIBLE IN USE WITH. FURNISHINGS IN PLACE, BEING USED YES L- - P EO P L E I N V O L V E D Code: OC OCCUPANT Name: WESTPORT SUPPLY CO. Address: 350 MIDLAND DR City: TUKWILA ST: WA Phone: (206 ). 575-8605 DOB: / / Zip: 98188 CASUALTIES Fire Service Casualties: Injuries: 000 Non Fire. Service Casualties: Injuries: 000 Fatalities: 000 Fatalities: 000 COMPLETE FOR HAZARDOUS MATERIALS Area of Release: 45 SHIPPING, RECEIVING, LOADING AREA (+ Mail/Pac Release Level: A01. Rel Factor(s): 54 OTHER PART FAILURE, LEAK, BREAK Estimated # Chemicals Release: 001 TUKWILA FIRE DEPARTMENT Incident Number:. 9.5-002984-000 Incident Date: 09/06/95 Alarm Time: 1600 Equip. Involved: 39 AIR COND./REFRIG. NOT CLASSIFIED ADVE Action(s) Taken: 31 RESCUE, REMOVE FROM HARM (incl- EMS care to re : 44 ESTABLISH SAFE AREA Disposition: 2 INCIDENT COMPLETED WHILE FIRE SERVICE WAS PRE Haz Mat ID Sources Used 11 ON SITE: FD HAZ-MAT TEAM PERSONNEL Fire Service Haz Mat, Casualties: Injuries: 000 Non -Fire Service Haz Mat Casualties: Injuries: 000 CHEMICALS Fatalities: 000. Fatalities 000 Chem.Name: NATURAL GAS DOT ID: Hazard Class: DOT Hazard Class (F-4) Chemical Abstract #.: QTY Released: 00000 Units: . Contamination: Suspected Environmental Contamination (F-5) Container: TYPe: 11 PIPE . Material: 0 CONTAINER MATERIAL; INSF, INFO TO CLASSIFY FU Use: 1 FIXED Construction: 2 PRESSURIZED . Cap: 00000 Units: INCIDENT REPORT OFFICER IDENTIFICATION Member making report: SACHA, GARY C. Officer in charge: SACHA, GARY C. Shift: A Employee -ID: 1125 Report Date: 09/07/95 Member Signature: Officer in charge: page 1 TUKWILA FIRE' DEPARTMENT INCIDENT REPORT NARRATIVE Date. 09/06/95 Incident: 95-002984-000 E51,52,13,L54,A54,CH53,514 RESPONDED TO GAS LEAK IN THE BUILDING. E51 ARRIVED TO FIND BUILDING PARTIALLY EVACUATED. WE SUPERVISED THE EVACUATION, ASSURED THE GAS MAIN WAS SHUT DOWN AND STOOD BY UNTIL WASH NAT GAS USED A METER TO ASSURE THE BUILDING WAS SAFE TO RE-ENTER.GCS. acs- W 4.(194h Hist) y0w . n f X39 '•'8YcP 4 $116 %i/'fi984 . Entered 09/06/95 16:00:57 BY CRO4 /JOSEPH • Dispatched 09/06/95. 16:01:0.2 DY FD01 /CASTON Enrou.te 09/06/95 16:02:19 Onscene -09/06/95 16:04:43' Closed 09/06/95. 16:30:27 Initial Type: NGASIN Initial, Alarm Level: 1 Final Type: NGASIN (NATURAL GAS LEAK`INSIDE (2A)) Pri: 1 Dispo: Alarm Lev el: 1. Police TP1200 Fire TF5134 Group: T9 Beat: Police Rms:'- Fire Rms Medic Rms: Loc: 350 MIDLAND DR-,TUK -- WESTPORT SUPPLY CO Name: GAZAREK, JIM/EMP Addr: WESTPORT SUPPLY CO INC Phone: 575-8605 /1600 (JOSEPH) ENTRY GAS LEAK IN THE BLDG. /1600 $ASNCAS $TF95002984 /1601 (CASTON) DISP E51 #TF2037 SACHA, GARY #TF5221 BROOKS, JIM #TF1593 DYER, STEVE /16.01 ,ASST E52 #TF9281 EBERT, TED #TF5174 CUSTER, KORY #TF6370 BREWSTER, RICHARD /1601 ASST A54• #TF5814 HAGBERG, JOHN #TF2855 RODAL, BILL /1601 ASST E13 #RF0127 SHEFFER, RANDY #RF0067 MAUK, DAVE #RF0120 JAHN, DICK #S0045 S0045 /1601 ASNCAS E13 $RF95004627 / 1600? i ('JOSEPH) Supp. NAM: GAZAREK, JIM/EMP TXT: GAS LEAK ORIGINIATED IN FURNACE NEAR THE CE ILING, MAIN LINE, RP IS UNABLE TO GET THE GAS SH UT OFF. RP HAS EVAC. /1602 (******) ENROUT 13 /1602 (CASTON) ASSTER L54 /1602 ENROUT E52 •/1603 ASSTER CH53 #TF3842 ALDERSON, MIKE /1603 ENROUT E51 /1603 ENROUT A54 /1603. ,MISC ,WNG ALREADY ENROUTE, ETA ABOUT 10 MINS /1604 ASSTER TFSO [350 MIDLAND DR ,TUK] /1604 ONSCNE E51 /1604 ,MISC E51 IS EVACUATED /1605 ONSCNE CH53 /1605 MISC CH53 ,STAGE ON MIDLAND DR /1606 (WILLIT). CQNTCT L54 ,DELAYED BY TRAIN /1607 NEWLOC CH53 [MIDLAND ] /1608 MISC E51 ,GAS SHUT OFF LEAK HAS BEEN GOIN FOR SOME TIME. 1 DOOR OPEN IN THE BACK. WOULD LIKE TEAM TO CHEC. K BACK DOOR /1608,. ONSCNE E52 [STAGED HYDRANT J #TF6034 BYRON, CRAIG #TF7505 MCCOLLUM, DENNIS #TF4546 REES, RICHARD /1608 (**)!***) ONSCNE E13 /1609 (WILLIT) ONSCNE A54 / 1'610 CLEAR E13 iJ610 _ ('.f.RAR AFi4 /1611 (-CASTON) CLEAR TFSO. /1614 (WILLIT) -ONSCNE L54 /1&19, r. CONTCT. CH53 ,WNG ON, LOC & ADVISED OF PKWY CMD CALL AT WHAREH OUSE /1620 CONTCT CH53 ,SW CORNER STRONG ODOR CHECKING FOR CAUSE . /1626 CLEAR E52 /1626 CLEAR CH53' ,/1626. CLEAR L54 /1630 (CASTON) CLEAR E5,1 /1630 CLOSE ,E51