Loading...
HomeMy WebLinkAboutHAZMAT 96-1589 - 17000 SOUTHCENTER PKWY - IDENTIFICATION/ANALYSIS OF HAZARDOUS MATERIAL ON 5/14/199617000 SOUTHCENTER PKWY IDENTIFICATION/ANALYST S OF HAZARDOUS MATERIAL HAZMAT # 96-1589 • TUKWILA FIRE DEPARTMENT FIRE INCIDENT REPORT ,44-q -is q per;. cuPE- FDID: 17M19 Date: 05/14/96 Dispatch: 0956 First Co: E51 Aid: 0 Alarm Method: 1 Weather: 2 Situation(s): 42 Action(s) Taken: Incident No: 96-001589-000 Multi -Agency: Arrival: 1002 End: 1217 Days: 0 Response: 0 06 District: ,006 Temperature: 055 (F) 31 33 42 Property Mangmnt: 1 Address/Location: Room/Apartment: City/State: TUKWILA, WA Hazard Zone: NO AUTOMATIC/MUTUAL AID RECEIVED OR PROVIDED TELEPHONE DIRECT TO FIRE DEPARTMENT CLOUDY . TOXIC CONDITION RESCUE, REMOVE FROM HARM PROVIDE EMERGENCY MEDICAL SERVICE IDNTIFICATION/ANALYSIS OF HAZARDOUS MATERIAL PRIVATE TAX -PAYING PROPERTY - 17000 SOUTHCENTER Personnel Apparatus Aerial: 01 Paid: 0012 Engine; 002 Command: 01 GeneralUse: 80 Specific Use: 894 Bldg Occupancy: B4 Struct. Status:.2 Occupied?: 1 PY Zip: 98188--0000 Census Tract: 0262.00 Volunteer: 0000 Truck: 00 Medical: 01 Other: 00 Tanker:, 00 Rescue: 00 Hazmat: 01 STORAGE, WAREHOUSING USE FREIGHT TERMINAL FACTORIES, WORKSHOPS, STORAGE NON-COMBUSTIBLE IN 'USE .WITH FURNISHINGS IN PLACE., BEING USED YES. CASUALTIES Fire Serviice Casualties: Injuries: 000 Non Fire Service Casualties: Injuries: 000 Fatalities: 000 Fatalities: 000 Area of Release: 69 Release Level: A03 Rel Factor(s): 22 COMPLETE FOR HAZARDOUS MATERIALS SERVICE, EQUIP. NOT CLASSIFIED - Explain in C NEGLIGENCE/RECKLESS'—ADULT Estimated # Chemicals Releaser 001 Equip. Involved: 60 SPECIAL EQUIP INSF. INFO TO CLASSIFY FURTHER Actions) Taken: 31 RESCUE, REMOVE FROM HARM (incl EMS care to re 33 'PROVIDE EMERGENCY MEDICAL SERVICE . 42 IDENTIFICATION/ANALYSIS OF HAZARDOUS'MATERIAL 4 TUKWILA FIRE DEPARTMENT Incident Number: 96-001589-000 Incident.Date: 05/14/96 A l ar m . T.i me : 0956' Disposition: 7 INCIDENT SCENE RELEASED TO PRIVATE AGENCY Haz Mat ID Sources Used: 13 ON SITE: FD HAZ-MAT SPECIALIST, TECHNICIAN 87 OFF SITE COMPUTER SOFTWARE Fire Service Haz Mat Casualties: - Injuries: 000 Ikon -Fire Service Haz, Mat Casualties: Injuries: 000 CHEMICALS Chem.Name: 50 MALATHI Hazard Class: 6 Chemical Abstract #: Physical State: Stored: 2 Released: 2 QTY Released.: 00032 Extent of Release: 6 Contamination: 8 Container: Type: 04 Material,: 7 Use: 2 Construction: Cap: 00032 Fatalities: 000 Fatalities: 000 ON DOT ID: Class 6 - POISONOUS AND INFECTIOUS SUBSTANCES LIQUID (incl. cryogenics) LIQUID (incl. cryogenics) Units: 11 OUNCE CONFINED TO. SPECIFIC PROPERTY USE 'OF ORIGIN NO ENVIRONMENTAL IMPACT CAN/BOTTLE GLASS PORTABLE 9 CONTAINER CONSTRUCTION NOT CLASSIFIED-Expiai Units: 11 OUNCE INCIDENT REPORT OFFICER IDENTIFICATION Member making report: LT. LOREN J. MCFARLAND Officer: in charge: LT. LOREN J. MCFARLAND Shift: B Employee ID: 1119 Report Date: 05/16/96 Member Signature: Officer in charge: Page, 1 TUKWILA FIRE DEPARTMENT INCIDENT REPORT NARRATIVE Date: 05/14/96 Incident: 96-001589000 DISPATCHED TO THE SMELL OF PESTICIDE IN A DUMPSTER. UPON ARRIVAL ON THE SOUTH SIDE OF THE BON DC FOUND A COMPACTOR DUMPSTER PULLED AWAY FROM THE COMPACTOR UNIT WHICH IS BUILT INTO THE BUILDING. THERE WERE TWO EMPLOYEES PULLING. GARBAGE OUT OF THE DUMPSTER AND ONTO THE GROUND. MET WITH BON REP. HE STATED THAT A CANHOF BUG SPRAY HAD BEEN TROWN INTO THE COMPACTOR AND THAT THEY WERE DIGGING IT OUT. UPON GETTING. CLOSE TO THE DUMPSTER COULD SMELL THE DEFINITIVE ODOR OF A PESTICIDE. ADVISED THE EMPLOYEES IN THE AREA TO GET OUT OF THE AREA. ASKED HOW THE DUMPSTER HAD BEEN PULLED OUT FROM THE COMPACTOR UNIT. IT WAS STATED THAT A YARD TRACTOR HAD BEEN USED. ASKED IT THE DUMPSTER. COULD BE PULLED OUT FROM THE BWILDING INTO THE DRIVE SO THAT IT WAS POINTING EAST/WEST WITH THE REAR WEST. THIS WAS ACCOMPLISHED. CALLED FOR ADDITIONAL HELP FROM E-52, HZ MAT 52 AND AID 54. BON REP STATED THAT THERE .WAS AN ODOR IN THE BUILDING WITH IT BEING MOSTLY IN THE SECOND FLOOR AREA. STATED THAT WINDOW VENTS, ROLL -UP DOORS, ROOF FANS, AND PORTABLE FANS HAD ALL BEEN ACTIVATED AND THAT THE ODOR WAS DISIPATING. HAD THE UPSTAIRS EVACUATED. MARKED OFF A HOT ZONE. CALLED FOR DUTY CHIEF AND ADDITIONAL HELP OF"L--54 WITH HAZ MAT TECHS. BON REP STATES THAT NO EMPLOYEE HAS TOUCHED THE SPILLED MATERIAL, FIND RESIDUE OF PRODUCT IN THE COMPACTOR AND BELIEVE CONTAINER I5 IN THE DUMPSTER, BON REP STATES MORE THAN ONCE THAT THERE COULD NOT BE ANY PESTICIDE IN THE DUMPSTER. SEVERAL MINUTES LATER HE NOW STATES THAT HE DOES REMEMBER A BOTTLE OF DIAZANON OR MALATHION THAT HAD BEEN STORED IN THE SHOP. THEY HAVE JUST FINISHED A MAJOR HOUSECLEANING OF THE SHOP. AN EMPLOYEE NOW STATED THAT HE DID DISPOSE OF A BROWN GLASS BOTTLE INTO THS COMPACTOR. DECIDE TO HAVE THE COMPLETE BUILDING EVACUATED. AT THES TIME OF EVACUATION ELEVEN EMPLOYEES COME TO THE AID CAR WITH VARYING CQMPLA0INTS OF DIZZINESS AND NAUSEA, IT IS FOUND IN INTERVIEWIING THESE EMPLOYEES THAT ONE OF THEM HAD BEEN IN THE COMPACTOR WITH A BLANKET WIPING UP THE SPILLED PRODUCT, HE HAD IT ON HIS HANDS BUT HE HAS WASHED THEM. THIS PATIENT IS SENT ASIDE TO STRIP AND. CHANGE INTO COVERALLS. HE IS TRANSPORTED TO THE HOSPITAL AS WELL AS ONE OTHER EMPLOYEE AT THIS TIME. HAZ MAT TEAM DISCUSSES THE SITUATION AND IT IS DECIDED THAT A TEAM WILL ENTER THE HOT ZONE IN BUNKERS AND ArR PACKS TO ATTEMPT,TO FIND A LABEL OR CONTAINER OF THE SPILLED PRODUCT. PLASTIC IS SPREAD ON THE GROUND AT THE REAR -0F THE DUMPSTER. THE REAR DOOR OF THE DUMPSTER IS OPENED AND MATERIAL IS PULLED, OUT. TEAM USES UP A BOTTLE OF AIR AND NOTHING IS FOUND. BON REP STATES THAT BY A DESCRIPTION OF THE GARBAGE BEING REMOVED THE SPILLED CONTAINER SHOULD BE VERY CLOSE, TEAM RETURNS ON AIR AND WITHING TWO MINUTES A BROKEN GLASS BOTTLE OF 50 MALATHION IS FOUND. ALSO A SPRAY CAN OF BUG X IS LOCATED BUT THIS CONTAINER IS STILL INTACT AND FULL OF PRODUCT. AN INDEPENDENT CLEAN-UP CONTRACTOR HAS BEEN CONTACTED BY THE BON AND HE IS ON LOCATION. IT IS MADE KNOWN TO IC, HAZ MAT TECHS, MEDICAL, BON REPS AND THE CLEAN-UP CONTRACTOR AS TO_THE PRODUCT FOUND, ENTRY TEAM AND TOOLS ARE DECONDED WITH TIDE AND THE SCENE IS TURNED OVER TO PRIVATE.CLEANUP. . BUILDING IS CHECKED INSIDE AND FOUND TO BE CLEAR WITH EXCEPTION OF A VERY SLIGHT ODOR UPSTAIRS. OK IS GIVEN FOR BUILDING TO BE OCCUPIED. THREE FEMALED EMPLOYEES COMPLAIN IMMEDIATELY ABOUT THE ODORUPSTAI AND REPORT TO MEDICAL. THEY ARE ALL•THREE SENT TO THE HOSPITALFOR CHECK UPS DUE TO THE FACT THAT ALL THREE OF THEM ARE PREGNANT. Page 2 TUKWILA FIRE DEPARTMENT INCIDENT. REPORT NARRATIVE, Date: 05/14/96 Incident: 96-001589-000 SCENE IS DOWNGRADED, PICKED UP AND ALL UNITS RETURN. * ^ Incident History for: #TF96001516 CN: STF96001589 Received Entered Dis atched Enroute Onscene Closed 05/14/96 05/14/96 05/14/96 05/14/96 05/14/96 05/14/96 09:56:41 09:56:41 09:56:52 09:58:09 10:02:03 12:17:36 BY CR03' /SEARS BY CRO3 /SEARS BY FDO1 /JOSEPH Initial Type: ODORXT Initial Alarm Level: 1 Final Type: HZLEAK (HAZD CHEMICAL SPILL LEAK .(2A)) Pri: 2Dispo: Alarm Le vel: 1 Police TP1000 Fire TF5131 Group: T9 Beat: PoliceRms: Fire Rms: Medic Rms: Loc: 17000 SOUTHCENTER PY ,TUK ~- BON MARCHE DISTRIB Name: HAGGEN. MICHAEL/SEC Addr: BON MARCHE THE Phonea.575-2060 ' /0956 SEARS CRO3 ENTRY ***IN REAR OF S SIDE OF THE ABOVE" 2 FT FR OM BLDG" SMELL _OF PESTICIDE IN A DUMPSTGR. /0956 CRO3 $ABNCAS $TF96001589 ' /0956 JOSEPH FDO1 DISP E51 #TF2016 MCFARLAN�. LOBEN #TF6037 BENNATTS. ROB /0958 .FD01 /1002 FD01 /1006 /1006 /1906 /1007 /1007 /1008 /1009 /1010 /1010 /10'0 /101l /1011 /1013 /1014 /10l5 /1015 /1016 /1o16' /1d17 /1[)18 /1020 /1020 /102O ENROUT E51 ONSCNE E51 ASSTER E52 [17000 SOUTHCENTER PY ,TUN] #TF7187 JnHNSC3 N. JEFF #TF3196 HICKEY. MATT #TF7946 GREEN. DAVE JOSEPH FD01 MISC ,E51 . ESTABLISHING BON COMMAND FDO1 ASSTER CH51 [17000 SOUTHCENTER PY ,TUK] #TF1312 KEFFE, TOM FDO1' ASSTER A54 ' #TF0449 MCCOY, MIKE . .#TF8793 CRQWLEY, MARK FD01 ASSTER HM52 #TF6370 BREWSTER. RICHARD FDO1 NEWLOC E51 [BON COMMAND ] FD01 ASST L54 #TF9526 GRISHAM, MARTY #TF9534 STEVENS, JACK #TF4923 FLORES. CI -RIS` FD01 CHANGE TYP: ODORXT FD01 F0U1 FD01 FD01 FDO1, FD01 FD01 ENROUT MISC ASSTER ONSCNE MISC MISC, MISC 154 L54 ApP5U9 A54 E51 L54 FD01 MISC ' E51 FD01 ONSCNE CH51 FD01 ONSCNE E52 FD01 ONSCNE: HM52 FD01 MISC E51 FD01 MISC E51 FD01 NEWLOC CH51 FDO1 NEWLOC E51 FD01 ONSCNE L54 ---> HZLEAK. . FROM STN 74/KENT APP509_RESPONDING FROM KEN T [17000 SOUTHCENTER PY .TUK] . NEG ON PD FOR TRAFFIC CONTROL • BE ADVISED THEY ARE ON PORTABLE . HAD UNK TYPE PESTICIDE THROWN IN TO DUMP F� STE, HAS BURST. FUMES HAVE MIGRATED. INTO THE BUILDING. UPSTAIRS PORTION OF BLDG HAS BEEN EVACTUATED • ON THE SOUTH SIDE OF THE BON DIST CTR, I N THE UNLOADING AREA. • HAZMAT VEH TOWARDS E51 • STRONG SMELL ON 2ND FLOOR [BON COMMAND] [17000 SOUTHCENTER PY "TK] . BASING APPARATUS OFF THE PY. BRI CREW / 1+02.1 ; ,FD01 /11)21-; FD01 /1028 KOWALC FD02 /1041 JOSEPH FD01 /1042 /1043 /1118 /1119 /1125 /1134 FD01 FD01 FD01 FD01 FD01 FD01 71139 KOWALC FD02 /1141 FD02 FD02 FD02 FD02 FD02 FD02 /1154 JOSEPH FD01 /1154 /1156 /1159 /1200 /1217 /1217. /1217 /1217 FD01 FD01 FD01 FD01 FD01 FD01 FD01 FDO1 UP MISC CH51- E52 AOS OLIS-.. E52 ONSCNE. APP509 MISC CH51 . , NEED.1 AMB, TOWROT CH5I AMB TUKKCA TUK KING COUNTY AMBULANCE MISC CH51 KCAMB FROM 154/PHS..- TOWROT -CH51 ' AMB SHEPT TUK SHEPARD AMBULANCE. MISC CH51 SHEP FROM TUKWILA` . MIS.0 CH51 4 .FOUND THE BROKEN BOTTLE• MORINS E52 MISC CH51 . TUK BACK TO FIRE ONE OK A54 OK APP509 OK CH51 OK E51 OK HM52 OK L54 CLEAR E51 CLEAR CH51 CLEAR L54 - TOWROT A54 'AMB SHEPT TUK SHEPARD AMBULANCE MISC A54 . SHEP FROM 154/HWY 'CLEAR A54' CLEAR APP509_ CLEAR HM52 CLOSE E5i TUKWILA FIRE DEPARTMENT FIRE INCIDENT REPORT FDIC): 17M19 Date: 05/14/9& Dispatch: 0956 First Co: E51 Incident No: 96-001589-000 Multi -Agency Arrival: 1002 End: 1217 Days: 0. Response: 0 06 District: 006 Temperature: 055 (F) Aid: 0 Alarm Method: 1 Weather: Met, Situation(s ): 42 Action(s) ,Taken: 31 33 42 Property Mangmnt: 1 NO AUTOMATIC/MUTUAL'AID RECEIVED -OR PROVIDED TELEPHONE DIRECT TO FIRE DEPARTMENT .CLOUDY TOXIC CONDITION RESCUE, REMOVE FROM HARM, PROVIDE EMERGENCY. MEDICAL 'SERVICE IDENTIFICATION/ANALYSIS OF,HAZARDOUS MATERIAL PRIVATE TAX -PAYING PROPERTY Address/Location: 17000 SOUTHCENTER PY Room/Apartm•ent: City/State: TUKWILA, WA Hazard Zone: • Personnel Apparatus Aerial: 01 Paid: 0012 Engine: 002 Command: 01 General Use: 80 Specific Use: 894 Bldg Occupancy: B4 Structs Status: 2 Occupied?: 1 Zip: 98188-0000 Census Tract: 0262.00 ' Volunteer: 0000 Truck: 00 Medical: 01 Other: 00 Tanker: 00 Rescue: DO • Hazmat: 01 STORAGE, WAREHOUSING USE FREIGHT TERMINAL FACTORIES, WORKSHOPS, STORAGE NON-COMBUSTIBLE IN USE WITH FURNISHINGS IN PLACE, BEING USED YES CASUALTIES. Fire Service Casualties: Injuries: 000 Non Fire Service Casualties: Injuries: 000 Fatalities: 000 Fatalities: 000 COMPLETE FOR HAZARDOUS,MATERIALS Area of Release: 69 SERVICE, EQUIP. NOT CLASSIFIED - Explain in C Release Level: A03 Rel Factor(s) : 22 NEGLIGENCE/RECKLESS -- ADULT Estimated # Chemicals Release: 001 Equip, Involved: 60 SPECIAL EQUIP INSF. INFO TO CLASSIFY FURTHER Action(s) Taken: 31 RESCUE, REMOVE FROM HARM (incl EMS care to re : 33 PROVIDE EMERGENCY MEDICAL SERVICE 42 IDENTIFICATION/ANALYSIS OF HAZARDOUS MATERIAL . - TUKWILA FIRE DEPARTMENT Incident Number: 96-001589-000 Incident Date: 05/14/96 'Alarm Time: 0956 Disposition: 7 INCIDENT SCENE RELEASED TO PRIVATE AGENCY Haz Mat ID Sources Used: 13 ON SITE: FD HAZ--MAT SPECIALIST, TECHNICIAN 87 'OFF SITE COMPUTER SOFTWARE Fire Service Haz Mat Casualties: Injuries: 000 Non -Fire Service Haz Mat Casualties: Injuries: 000. CHEMICALS Fatalities: 000 Fatalities: 000 Chem.Name: 50 MALATHION DOT ID:.' Hazard Class: 6 Class 6 - POISONOUS AND INFECTIOUS SUBSTANCES' Chemical Abstract #: Physical State: Stored: 2 LIQUID (incl. cryogenics) Released: 2, LIQUID (incl.. cryogenics) QTY Released: 00032 Units: 11 OUNCE Extent of Release: 6 'CONFINED TO SPECIFIC PROPERTY USE OF ORIGIN Contamination: 8 NO ENVIRONMENTAL IMPACT . Container: . Type: 04 CAN/BOTTLE Material': 7 GLASS Use: 2 PORTABLE Construction: 9 CONTAINER CONSTRUCTION NOT. CLASSIFIED -Explai Cap: 00032 Units: 11 OUNCE INCfDENT REPORT OFFICER IDENTIFICATION Member making report: LT. LOREN J. MCFARLAND Officer in charge: LT. LOREN J. MCFARLAND Shift: B Employee ID, 1119 Report Date: 05/16/96 Member Signature: Officer in charge. • • TUKWILA FIRE DEPARTMENT INCIDENT REPORT NARRATIVE Page 1 Date= 05/14/96 Incident= 96-001589-000 DISPATCHED TO THE SMELL OF PESTICIDE IN A DUMPSTER. UPON ARRIVAL ON THE SOUTH SIDE OF THE BON DC FOUND A COMPACTOR DUMPSTER PULLED AWAY FROM THE COMPACTOR UNIT WHICH IS BUILT INTO THE BUILDING. THERE WERE. TWO EMPLOYEES PULLING GARBAGE OUT OF THE DUMPSTER AND ONTO THE GROUND. MET WITH BON REP. HE STATED THAT A CAN OF BUG SPRAY HAD BEEN TROWN INTO THE COMPACTOR AND THAT THEY WERE DIGGING IT OUT. UPON GETTING CLOSE TO THE DUMPSTER COULD SMELL THE DEFINITIVE ODOR OF A PESTICIDE. ADVISED THE EMPLOYEES IN THE AREA TO GETOUT OF THE.AREA. ASKED HOW THE DUMPSTER HAD BEEN PULLED OUT, FROM THE COMPACTOR UNIT. IT WAS STATED THAT A YARD TRACTOR HAD BEEN USED. ASKED'IT THE DUMPSTER COULD BE PULLED OUT FROM THE BUILDING INTO THE DRIVE SO THAT IT WAS POINTING EAST/WEST WITH THE REAR WEST:. THIS WAS ACCOMPLISHED. CALLED FOR ADDITIONAL HELP FROM E-52, HZ MAT 52 AND AID 54. BON REP STATED THAT THERE WAS AN ODOR IN'THE BUILDING WITH IT BEING MOSTLY IN THE SECOND FLOOR AREA. STATED THAT WINDOW VENTS, ROLL -UP DOORS, ROOF FANS, AND PORTABLE FANS HAD ALL BEEN ACTIVATED AND THAT-THt ODORWASDISIPATING. HAD THE UPSTAIRS EVACUATED. MARKED OFF A HOT ZONE. CALLED FOR DUTY CHIEF AND ADDITIONAL HELP OF L-54 WITH HAZ MAT TECHS. BON REP STATES THAT NO EMPLOYEE HAS TOUCHED THE SPILLED MATERIAL. FIND, RESIDUE OF PRODUCT IN THE'COMPACTOR AND BELIEVE CONTAINER IS IN THE DUMPSTER. BON REP STATES MORE THAN ONCE THAT THERE COULD NOT BE ANY PESTICIDE IN THE DUMPSTER. SEVERAL MINUTES LATER HE NOW STATES THAT HE DOES REMEMBER A BOTTLE OF DIAZANON OR MALATHION THAT HAD BEEN STORED IN THE SHOP. THEY HAVE JUST FINISHED A MAJOR HOUSECLEANING OF THE SHOP. AN EMPLOYEE NOW STATED THAT HE DID DISPOSE OF A BROWN GLASS BOTTLE INTO THE COMPACTOR. DECIDE TO HAVE THE COMPLETE BUILDING EVACUATED. AT THIS TIME OF EVACUATION ELEVEN. EMPLOYEES COME TO THE AID CAR WITH VARYING COMPLAINTS OF DIZZINESS AND NAUSEA. IT I5 FOUND IN INTERVIEWIING THESE EMPLOYEES THAT ONE OF THEM HAD BEEN IN THE COMPACTOR WITH A BLANKET WIPING UP THE SPILLED PRODUCT. HE HAD IT ON HIS HANDS BUT HE HAS WASHED THEM. THIS PATIENT IS SENT ASIDE TO STRIP AND CHANGE INTO COVERALLS. HE IS TRANSPORTED TO THE. HOSPITAL AS WELL AS ONE OTHER EMPLOYEE AT THIS TIME. HAZ MAT TEAM DISCUSSES THE SITUATION AND IT IS DECIDED THAT A TEAM WILL ENTER THE HOT ZONE IN BUNKERS AND AIR PACKS TO ATTEMPT TO FIND A LABEL OR CONTAINER OF THE SPILLED PRODUCT. PLASTIC I5 SPREAD ON THE GROUND AT THE REAR OF THE DUMPSTER. THE REAR DOOR OF THE DUMPSTER IS OPENED AND MATERIAL IS PULLED OUT. TEAM USES, UP A BOTTLE OF AIR AND NOTHING IS FOUND. BON REP STATES THAT BY A DESCRIPTION OF THE GARBAGE BEING REMOVED THE SPILLED CONTAINER SHOULD BE VERY CLOSE. TEAM RETURNS ON AIR AND WITHING TWO MINUTES A BROKEN GLASS BOTTLE OF 50 MALATHION IS FOUND. ALSO :A SPRAY CAN OF BUG X IS LOCATED BUT THIS CONTAINER IS STILL INTACT AND FULL OF PRODUCT. AN INDEPENDENT CLEAN-UP CONTRACTOR HAS BEEN CONTACTED BY THE BON AND HE IS ON LOCATION. IT IS MADE KNOWN TO IC, HAZ MAT TECHS, MEDICAL, BON REPS AND THE CLEAN-UP CONTRACTOR AS TO THE PRODUCT FOUND. ENTRY TEAM AND TOOLS ARE DECONDED WITH TIDE AND THE SCENE IS TURNED OVER .TO PRIVATE CLEANUP. • BUILDING IS CHECKED INSIDE AND FOUND TO BE CLEAR WITH EXCEPTION OF A VERY SLIGHT ODOR UPSTAIRS. OK IS GIVEN FOR BUILDING TO BE OCCUPIED. THREE FEMALED EMPLOYEES COMPLAIN IMMEDIATELY ABOUT THE ODOR UPSTAIRS AND REPORT TO MEDICAL. THEY ARE ALL THREE SENT TO THE HOSPITAL F1R CHECK UPS DUE TO THE FACT THAT ALL THREE OF THEM ARE PREGNANT. 114 • Page 2 TUKWILA FIRE DEPARTMENT- INCIDENT REPORT NARRATIVE Date: 05/14/96 Incident: 96--001589--000 SCENE I5 DOWNGRADED, -PICKED UP AND ALL UNITS RETURN.