HomeMy WebLinkAboutHAZMAT 99-0708 - 17380 SOUTHCENTER PKWY - FLAMMABLE GAS OR LIQUID CONDITION (LEAK OR SPILL) ON 3/2/199917380 SOUTHCENTER
PKWY
FLAMMABLE GAS OR
LIQUID CONDITION (LEAK
OR SPILL)
HAZMAT # 99-0708
TUKWILA FIRE DEPARTMENT
FIRE INCIDENT REPORT
4g9 -0 -To
FDID: 17M19
Date: 03/02/99
Dispatch: 1503 Arrival:
First Co: E51
Aid: 1
Alarm Method: 7
Weather: 3
Situation(s): 41
Action(s) Taken: 63
Property Mangmnt: 1
Address/Location:
Room/Apartment:
City/State: TUKWILA, WA
Hazard Zone:
Incident No: 99-000708-000
Multi -Agency: 17M19-99-000708
1505 End: 1541 Days: 0 Response: 0 02
District: 0006 Temperature: 040 (F)
MUTUAL AID RECEIVED (By Contract)
TELEPHONE TIE -LINE TO FIRE DEPARTMENT (911 sy
RAIN
FLAMMABLE GAS OR LIQUID CONDITION (LEAK OR SP
NOTIFY OTHER AGENCIES
PRIVATE TAX -PAYING PROPERTY
17380 SOUTHCENTER PY
Zip: 98188-0000
Personnel
Apparatus
Aerial:
Paid:
Engine:
01 Command:
General Use: 16
Specific Use: 160
Bldg Occupancy: A3
Struct. Status: 2
Occupied?: 1
Census Tract: 0262.00
0012 Volunteer: 0000
002 Truck: 00 Medical: 01 Other: 00
00 Tanker: 00 Rescue: 00 Hazmat: 00
RESTAURANT, FOOD SERVICE, DRINKING ESTABLISHM
EATING, DRINKING PLACES:UNABLE TO CLASSIFY FU
BUILDING/ASSEMBLY ROOM LESS THAN 300, NO STAG
IN USE WITH FURNISHINGS IN PLACE, BEING USED
YES
CASUALTIES
Fire Service Casualties:
Injuries: 000
Non Fire Service Casualties:
Injuries: 000
Fatalities: 000
Fatalities: 000
Area of Release: 24
Release Level: A01
Rel Factor(s): 54
Estimated # Chemicals
Equip. Involved: 22
Action(s) Taken: 63
COMPLETE FOR HAZARDOUS MATERIALS
KITCHEN, COOKING AREA
OTHER PART FAILURE, LEAK, BREAK
Release: 001
FIXED, STATIONARY COOKING OVEN
NOTIFY OTHER AGENCIES (mut/auto aid, state, e
TUKWILA FIRE DEPARTMENT
Incident Number: 99-000708-000
Incident Date: 03/02/99
Alarm Time: 1503
Disposition: 2 INCIDENT COMPLETED WHILE FIRE SERVICE WAS PRE
Haz Mat ID Sources Used:
37 ON SITE NON-F.S.: LABORATORY PERSONNEL
Fire Service Haz Mat Casualties:
Injuries: 000 Fatalities: 000
Non -Fire Service Haz Mat Casualties:
Injuries: 000 Fatalities: 000
Member making report:
Officer in charge: LT
Shift: A
Employee ID: 1136
Report Date: 03/02/99
Member Signature:
Officer in charge:
INCIDENT REPORT OFFICER IDENTIFICATION
LT JEFF JOHNSON
JEFF JOHNSON
a
Page 1
TUKWILA FIRE DEPARTMENT INCIDENT REPORT NARRATIVE
Date: 03/02/99 Incident: 99-000708-000
E51, E14, L54, AND A54 PERSONNEL RESPONDED TO A SMELL OF NATURAL
GAS AT THE ABOVE LOCATION. UPON ARRIVAL, EMPLOYEES MENTIONED THAT THEY
COULD SMELL NATURAL GAS PERIODICALLY. THEY ALSO MENTIONED THAT THEY
HAD BEEN SMELLING IT OFF AND ON FOR 2 DAYS. E51 PERSONNEL WERE AT
FIRST UNABLE TO SMELL IT. WASHINGTON NATURAL GAS WAS NOTIFIED.
UPON ARRIVAL, WNG PERSONNEL LOCATED TWO NATURAL GAS LEAKS. ONE WAS
A PILOT LIGHT ON A STOVE WHICH WAS PLUGGED. THE OTHER WAS A TOASTER
OVEN WHICH HAD A SIGNIFICANT LEAK WHEN THE OVEN WAS USED. WNG ISOLATED
THE EQUIPMENT AND THE RESTAURANT MANAGER CALLED FOR HIS MAINTENANCE
PERSON TO FIX THE PROBLEM. E51 RETURNED.
°
Incident History
Received
Entered
Dispatched
Enroute
Onscene
Closed
tor: #TF99000673 CN: $TF99000708
03/02/99 15:02:27 BY CRO1 /WANDRE
03/02/99 15:03:08 BY CRO1 /WANDRE
03/02/99 15:03:20 BY FD21 /LAWREN
03/02/99 15:05:03
03/02/99 15:05:41
03/02/99 15:41:58
4tt 01
Initial Type: NGASIN Initial Alarm Levi:a1
Final Type: NGASIN (NATURAL GAS LEAK INSIDE (2A)) Pri: 1 Dispo:
ev: 1
Police TP1100 Fire TF5134 Group: T9 Beat:
Police Rms: Fire Rms: Medic Rms:
Loc: 17380 SOUTHCENTER PY .TUK -- STANFORDS RESTAURA
Name: OANER, DAN/EMPLOYEE Addr: STANFORDS BAR GRILL
/1503 WANDRE CRO1
/1503 CRO1
/1503 LAWREN FD21
/1503 FD21
/1503
/1503
/1503
/1503
/1503
/1503
/1504
/1505
/1505
/1505
/1505
/1505
/1507
/1509
/1509
/1510
/1510
/1512
/1513
/1517
FD21
FD21
FD21
FD21
WANDRE CRO1
LAWREN FD21
TF8163
MASSIC
S0049
MASSIC
RICKER
TF8163
******
RICKER
L54
FD22
E14
FD22
FD22
FD22
L54
TPD3
FD22
FD22
FD22
FD22
FD22
/1529 LAWREN FD21
/1541 TF7187 E51
/1541 E51
Alrm L
Phone: 575-7454
ENTRY ODOR OF NAT GAS IN THE LOBBY.
$ASNCAS $TF99000708
DISP E51 #TF7187 JOHNSON. JEFF
#TF5221 BROOKG, JIM
#TF0001 TUKWILA FIRE RADIO
#TF7505 MCCOLLUM. DENNIS
ASST E14 #S0049 S0049
#RF0058 DEINES. BOB
#RF0127 SHEFFER, RANDY
#RF0108 HOLT. JOHN
ASNCAS E14 $RF99001266
ASST A54 #TF5504 ROBERTS. MARTY
#TF8793 CROWLEY, MARK
ASST L54 #TF8163 EWING, DAVE
#TF3859 LUCER°. BRIAN
#TF4546 REES, RICHARD
#TF1165 MCCOY. PAT
F2 #F2 ** RESPOND ON FIRE
F2 $XF99001072
TXT: RP NOT EVAC..
GRP: T9
---> X8.
ASST
ASNCAS
SUPP
CONTRL
*ENROUT L54
CLEAR F2
*ENROUT E14
ONSCNE E51
ENROUT A54
MISC E51
MOBINS L54
MOBINS E14
CLEAR A54
MISC E51
MISC E51
MISC E51
CONTRL
CONTCT E51
MOBINS E51
CLOSE E51
• 75X75 NVI
,ALL INCOMING UNITS YELLOW
.CALL WASH NAT GAS
,ALL INCOMING UNITS GREENED
.ETA ON GAS 20 MIN
GRP: X8
- --> T9.
. WNG ON LOCN
2 **