Loading...
HomeMy WebLinkAboutHAZMAT 99-2861 - 1160 SAXON DR - SPILL (FLAMMABLE LIQUID SPILL) ON 8/29/19991160 SAXON DR SPILL (FLAMMABLE LIQUID SPILL) HAZMAT # 99-2861 .410 TUKWILA FIRE DEPARTMENT FIRE INCIDENT REPORT 00 -1? --S Le I FDID: 17M19 Date: 08/29/99 Dispatch: 1757 First Co: E51 Incident No: 99-002861-000 Multi -Agency: Arrival: 1800 End: 1845 Days: 0 Response: 0 03 District: 005 Temperature: 064 (F) NO AUTOMATIC/MUTUAL AID RECEIVED OR PROVIDED TELEPHONE TIE -LINE TO FIRE DEPARTMENT (911 sy CLOUDY FLAMMABLE GAS OR LIQUID CONDITION (LEAK OR SP REMOVE HAZARD PRIVATE TAX -PAYING PROPERTY Aid: 0 Alarm Method: 7 Weather: 2 Situation(s): 41 Action(s) Taken: 41 Property Mangmnt: 1 Address/Location: Room/Apartment: City/State: TUKWILA, WA Hazard Zone: 1160 SAXON DR Personnel Apparatus Aerial: 00 Paid: Engine: Command: General Use: 96 Specific Use: 965 Bldg Occupancy: 000 Struct. Status: 0 Occupied?: 0 Zip: 98188-0000 Census Tract: 0262.00 0003 Volunteer: 0000 001 Truck: 00 Medical: 00 Other: 00 00 Tanker: 00 Rescue: 00 Hazmat: 00 MOTOR VEHICLE TRANSPORTATION USE (incl pass t UNCOVERED PARKING AREA BUILDING CODE OCCUPANCY TYPE NOT APPLICABLE STRUCTURE STATUS UNDETERMINED OR NOT REPORTED CASUALTIES Fire Service Casualties: Injuries: 000 Non Fire Service Casualties: Injuries: 000 Fatalities: 000 Fatalities: 000 Area of Release: 84 Release Level: A02 Rel Factor(s): 21 Estimated # Chemicals Equip. Involved: 01 Action(s) Taken: 41 COMPLETE FOR HAZARDOUS MATERIALS FUEL TANK, FUEL LINE AREA OF TRANSPORTATION E NEGLIGENCE/RECKLESS - PERSON(S) UNKNOWN Release: 001 ROAD TRANSPORT VEHICLE REMOVE HAZARD (NOT INCL. decontamination -47) OK TUKWILA FIRE DEPARTMENT Incident Number: 99-002861-000 Incident Date: 08/29/99 Alarm Time: 1757 Disposition: 1 INCIDENT COMPLETED BY FIRE SERVICE ONLY Haz Mat ID Sources Used: 11 ON SITE: FD HAZ-MAT TEAM PERSONNEL Fire Service Haz Mat Casualties: Injuries: 000 Non -Fire Service Haz Mat Casualties: Injuries: 000 Chem.Name: GASOLINE Hazard Class: Chemical Abstract #: Physical State: Stored: 2 Released: 2 QTY Released: 00005 Extent of Release: 7 Contamination: 6 Container: Type: 19 Material: Use: 3 Construction: Cap: 00030 1 9 CHEM I CAL S Fatalities: 000 Fatalities: 000 DOT ID: DOT Hazard Class (F-4) LIQUID (incl. cryogenics) LIQUID (incl. cryogenics) Units: 12 GALLON RELEASED BEYOND SPECIFIC PROPERTY USE OF ORIG WATER & GROUND CONTAINER TYPE NOT CLASSIFIED ABOVE -Explain IRON, IRON ALLOYS MOBILE CONTAINER CONSTRUCTION NOT CLASSIFIED -Explai Units: 12 GALLON Member making report: Officer in charge: LT Shift: A Employee ID: 1119 Report Date: 08/29/99 INCIDENT REPORT OFFICER IDENTIFICATION LT. LOREN J. MCFARLAND . LOREN J. MCFARLAND Member Signature:(72) Officer in charge:Jkisi • Page 1 TUKWILA FIRE DEPARTMENT INCIDENT REPORT NARRATIVE Date: 08/29/99 Incident: 99-002861-000 DISPATCHED TO A REPORTED GASOLINE LEAK FROM THE FUEL TANK OF A PICKUP TRUCK. UPON ARRIVAL LOCATED VEHICLE WITH A SOLID STREAM OF GASOLINE POURING FROM UNDER THE VEHICLE AT JUST ABOUT BEHIND THE CAB. FOUND THAT THE FUEL LINE HAD BEEN REMOVED FROM AN ELECTRIC FUEL VALVE AND THAT THERE WAS AN OPEN PORT POURING OUT FUEL. ALSO FOUND THAT SOMEONE HAD TAKEN OFF TWO DIFFERENT LINES AND USED A PIECE OF PLASTIC TUBING PUSHED INSIDE TO CONNECT THESE TWO TOGETHER. NO CLAMPS HAD BEEN USED. PULLED OUT THE TEMP INSERTED PLASTIC TUBE AND CONNECTED LINES BACK TO THE ELECTRIC FUEL VALVE. THE LEAKING STOPPED. HAD NO CLAMPS TO SECURE THE FUEL LINES BUT THEY WERE NOT LEAKING. SPREAD RICE HULL ASH ON THE GROUND AND USED PADS AT THE STORM DRAIN WHERE THE FUEL WAS RUNNING TO STOP IT FROM FURTHER ENTERING THE DRAIN SYSTEM. PICKED UP THE PADS AND SWEPT UP THE RICE HULL ASH AND DUMPED IT INTO THE DUMPSTER AT STATION 51. COSTCO WAS CLOSING SO WAITED FOR THE OWNER OF THE TRUCK TO COME OUT. NO ONE CAME OUT TO CLAIM THE TRUCK. FOUND OUT THAT THE TRUCK HAD BEEN PARKED OVER NEXT TO THE BUILDING EARLIER AND HAD BEEN LEAKING FUEL THERE ALSO. IT WAS THEN MOVED ONTO THE HILL JUST ABOVE THE STORM DRAIN SO THAT THE FUEL WOULD RUN INTO THE DRAIN SYSTEM. 1984 FORD TRUCK, TAN 2FTCF15F7ECA14914 JULY 2000 DEAN G. CHAPMAN PO BOX 6163 FEDERAL WAY, WA 98003 SINCE NO ONE ARRIVED TO CLAIM THE VEHICLE I REMOVED THE COIL WIRE FROM THE ENGINE SO THAT IT COULD NOT BE DRIVEN AWAY LATER THIS EVENING. RETURNED. • -44F9q-z861 Incident History ror: #TF99002711 CN: $TF99002861 Xref: #TP9902t310 Received 08/29/99 17:54:58 BY CRO2 /PITARD Entered 08/29/99 17:57:10 BY CRO2 /PITARD Dispatched 08/29/99 17:57:26 BY FD21 /WILLIT Enroute 08/29/99 17:59:49 Onscene 08/29/99 18:00:53 Closed 08/29/99 18:45:42 Initial Type: SPILL Initial Alarm Level: 1 Final Type: SPILL (FLAMMABLE LIQUID SPILL (2A)) Pri: v: 1 Police TP1200 Fire TF5135 Group: T9 Beat: Police Rms: Fire Rms: Medic Rms: Loc: 1160 SAXON DR ,TUK -- COSTCO WHOLESALE Name: HARRIS, CRAIG/SEC Addr: COSTCO WHOLESALE Contact: N /1757 PITARD CRO2 /1757 CRO2 /1757 WILLIT FD21 ENTRY $ASNCAS DISP E51 /1757 PITARD CRO2 SUPP /1759 TF2016 E51 *ENROUT E51 /1800 E51 *ONSCNE E51 /1801 SANTIN PD33 CROSS /1845 TF2016 E51 IQIS E51 /1845 E51 CLOSE E51 2 Dispo: Alrm Le Phone: 575-4567 VEH IN THE P/L LEAKING GAS FROM GAS TANK - GAS IS DRIZZLING FROM THE TANK - UNK HOW MUCH LEANED SO FAR - VEH IN THE NE CORNER OF THE LOT - VEH IS TAN F ORD TRUCK WITH T AN CANOPY L/FX6938 $TF99002861 #TF2016 MCFARLAND, LOREN #TF5504 ROBERTS, MARTY #TF0001 TUKWILA FIRE RADIO #TF9874 WILLIS, BRIAN TXT: RP AT THE FRONT DOOR TO DIRECT FD IF NEEDED #TP99026310