Loading...
HomeMy WebLinkAboutPP - 16925 SOUTHCENTER PKWY - ELITE DRESS BRIDAL - PERMITS AND PLANS16925 SOUTHCENTER PKWY ASSOCIATED PERMITS 19-F-024 D18-0275 SITE LOCATION Rot CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Addres . Southcenter Pkwy, Tukwila, WA 98188 Suite Number: p, Floor: Tenant Name: ELite Dress & Bridal TI New Tenant? Q - Yes ❑ - No Property Owner's Name: Nataliya Bindas Mailing Address: 3315 133rd St SW, #106, Lynnwood, WA 98087 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Leo Kot Day Telephone: (253) 737-7015 Company Name: Kot Electric LLC Mailing Address: 1513 105th Ave Ct E, Edgewood, WA 98372 lonka1992@gmail . com City State Zip E-mail Address: Fax Number: Contractor's City of Tukwila NICET III number: Business License number: Total number of new/relocated devices or sprinkler heads: 5 Valuation of Project (contractor's bid price): $ 3000 Scope of Work (please provide detailed information): Relocate Existing Device and Add new additional devices to accommodate New TI. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDINGR AUTHORIZED AGENT: Signature: Print Name: Leo Kot Plan Permit App.doc Date: 02/03/2019 Day Telephone: (253) 737-7015 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1.11$ o PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: eitie_ All) r..d40 Ka otAi Type of Inspection: /....- A.. ...--- ,(101 Address: Suite #: /)7' Sc.. P4 -(Al Contact Pe n: Special Instructions: Phone No.: Monitor: Approved per applicable codes. COMMENTS: Corrections required prior to approval. frepv f46ei's /rr� 1444/ 40444 —19SS Needs Shift Inspection: Sprinklers: Date: 3n A 1 Fire Alarm: Hood & Duct: / ., o Monitor: Pre -Fire: Permits: Occupancy Type: / U A, ' 1 Inspector: & Wil Date: 3n A 1 firs.: 9.0 2 / ., o $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Dla-bZ�s PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: l l 1L- �r yeA ( Type of Inspection: v,Q.1/— Address:� Suite #: ko� � VG ^\ 1 bki Contact Person: Special Instructions: Monitor: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMI IIENTS: -�-'-- yeA Sprinklers: Y.,4 MAig Fire Alarm: ..eo 0 V__ Az) COL ir Hood & Duct: Monitor: N i (L Af M t4 _v rpt b -stead Frit_ 44442-4,q. 4- Occupancy Type: A/ - Nee- t• - e M tee 71 26 59(.., a 04-4114 - *1 etrzFey- Z i ,w a "7 2-eeS, Needs Shift Inspection: yeA Sprinklers: Y.,4 MAig Fire Alarm: ..eo / „ 0 Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: A/ Inspector: / I "."4- / MAig Date: /2/1 %/ g Hrs.: / „ 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Norita Deckard From: Ben Hayman Sent: Tuesday, November 6, 2018 3:52 PM To: Arthi Chand;'dylanbailey@waterdistrict125.com'; Fessenden, Janise; Janine Springer (Janine.M.Springer@usps.gov); Jeremy DelMar; Joanna Fortenberry; Norita Deckard; PSE Addressing - PSE (ServiceAddressCorrec@pse.com); Rachelle Ripley; Roman Linsao; scottco@Valleycom.org; Shane Young; 'Tina.c.Fisher@usps.gov'; Valley View Sewer District (valvue@valleyviewsewer.org) Subject: Address Addition for Tukwila Hello, My name is Ben Hayman and I am the new Fire Marshal for the City of Tukwila. Don Tomaso has recently returned to shift, so I will be the Tukwila Fire Department contact for address changes. Please update your addressing information to show that PIN 2623049011 has been assigned an additional address of 16925 Southcenter Parkway. Thank you, Ben Ben Hayman 1 Battalion Chief Tukwila Fire Department I Fire Marshal Email: Ben.Hayman@TukwilaWA.gov Main: 206-971-8723 1 2 • \ • -. • -• fq-F-02`\ IntelliKnight® 5808 Single Loop Addressable Fire Alarm Control System The convenience of an addressable fire alarm control panel in a cost-effective easy to use package. IntelliKnight Model 5808 is a 127 point class leading,single loop addressable fire alarm control/communicator system. 58084providei\you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital comr t6nication)distributed,intelligent power, easy to use interface. Powerful features such as drift compensation and maint nance''alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest -source, please.call 1-800-328-0103, or in Connecticut, call 203-484-7161. Description O The basic 5808 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5808 supports Hochiki or SK'protocol devices. 5808 also features a powerful built-in dual line fire communicator that allows for reporting of all system acti ity to a remote monitoring location. Features • Built-in support for up to 127 Hochiki�devices o detectors and 99 SK modules �J • Up to 125 zones and 125 output groups • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator • Central station reporting by point ori6y zone • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC • Distributed, intelligent power • Drift compensat5 v �--� • 13 pre-programmed output cadences,!(including ANSI -3.41), and 4 programmable outputs /.1( kms/ • Notificationfcircuits can b'config �ed as 2Class A (Style Z) or 4 Class B (Style Y), orrauxiliary powerr'for resettable, consta9„t-or door holder power ) • Built-in annunciatorwith 80 -character LCD display • RS -485 bus provides communicaffon to system accessories • Built-in RS -232 and USB ihterfaee for programming via a PC • Upload or download programming, event history, or detector status via remote or direct connection • Improvements in SKSS deliver five times faster upload/downloads • Built-in synchronization for appliances from AMSECO, Gentex®, Faraday, System Sensor®, and Wheelock® • One Form C trouble relay rated at 2.5A at 27.4 VDC and two Form C programmable relays rated at 2.5A at 27.4 VDC • Programmable date setting for Daylight Saving Time • Plex-2 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Model 5808 • Integrated dead front panel protects operator from exposure to electrical components • The FACP enclosure features a Plexiglass® viewing window to protect annunciator • Acknowledge function allows operator to keep track of event status Installation The 5800 can be surface or flush mounted. Compatibility The 5808 SLC supports multiple device types of the same protocol: • Hochiki • SK You cannot mix Hochiki and SK devices on a FACP. However, any combination of addressable devices of the same protocol can be used on the 5808. ElSILENT eKNIG - Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.75A Total Accessory Load: 6A @ 27.4 VDC Notification Power: 6A @ 27.4 VDC, power -limited Standby Current: 170 mA Alarm Current: 325 mA Notification & Auxiliary Circuits: 3A @ 27.4 VDC per circuit,power-limited Battery Charging Capacity: 7.0-35.0 AH Battery Size: 18 AH max. allowed in FACP. Larger capacity batteries can be housed in an RBB accessory cabinet Physical Flush Mount Dimensions: 14.5" W x 24.75" H x 3.5" D (36.8 W x 62.9 H x 8.73 D cm) Overall Dimensions: 16" W x 26.4" H x 4.65" D (40.6 W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red Telephone Requirement/ FCC Part 15 and Pary68 approved Type of Jack: RJ31X,(two required) Approvals NFPA 13, NFPAc... ,NFPA'16WNFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective\SJgnIli`g Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service• Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 142; MEA 429-92-E Vol. XIV S -BUS Accessories 5860/R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and fire/fighfr's key switch as the 5808. 5860 i 'gray and 5860R is red. 1*N.i' 5496 Intelligent Pow ,Modute A 6 amp notification powere pander that provides fouf'additional•power limited notification appliance circuit outputs. ._ '5880 LED/IO Modul Feature's40 LED outputs, Normally . open dry contact nput�done piezo output( ` 5865-3 and 5865-4 4Remote LED Annunciator Features 30 programmable LED (15 re 1'and 15 yellow) outputs and a piezo sounder.,The 5865-4 adds a silence and reset switch to the package.f 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS -232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 0 5496 Miscellaneous Accessories / I1 5660 Silent Knight Software Suite PC-bbias �oftware�for F SCP programming�Uplo d and view panel C information, event history, and detector status. 5670 Silent Knight Software Suite Enid user facility management software allogis viewing of detector status and event history via modem or direct connection. Plex-2 Door Dead front cabinet door with clear window to limit access to the FACP. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D(406 mm W x 254 mm H x 152 mm D) SD505-DTS-K Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505-DUCTR. Hochiki and SK Devices See the specification sheets listed below for a complete listing of the Hochiki and SK devices. 53624 Hochiki Devices Specification Sheet 53623 SK Device Protocol Devices Specification Sheet col SILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com IntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight MADE IN AMERICA 350386 Rev. F ECN 09-520 09/09 © 2009 Honeywell International Inc. Model 5495 Distributed Power Module In an emergency, you need maximum power. The 5495 Distributed Power Module by Silent Knight s the most powerful and cost-effective power supply available today. It delivers 6 amps ofr otification appliance circuit power and built-in synchronization for ppliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday — what you need to drivun erpowerrhgry components like ADA notification appliances. The 5495's advanced microprocessor design�us-years ahead of the competition. Its switch mode power supply design is up to 50% more effiaent-than competitivellinear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new component° For the most sophisticated and cost-effective notification power supply available;,you need the 5495. CaII Silent Knight today for more information at 1-800-446-6444. Model 5495 Distributed Power Module The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features • UL Listed for/6'amps of notification power • Power ss Spply' advancedswitch mode design reduces 6maging heat and manages,power up to 50% more efficiently than other systremmas • Dip switches allow for easy. reconfiguration • 24 VDC filtered output voltage • Four power -limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B • Additional continuous auxiliary output • 3 amps per output circuit • 2 inputs; 2 Class B or 2 Class A • Ground fault detector/indicator • Independent tro�ub rel • AC loss delay opti6n�shots off power to non-essential high-6urrent accessories,like\magnetic door holdersf(/ Built-in s nchonizati appliances fromSystem�� Sensor®,Gentex®, AMSECO®, Wheelbck�eand Faraday • Stand alone � operation • Lightweight'desigreadds to ease of Vnstallation and reduces shipping costs It • Operates with most polarized, UL Listed notification devices • L 8641& 1481 listed • CSFM approved • ANSI Cadence pattern output capability built-in Connection to Local Fire Control The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end -of -line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the .111Nf AYll.lfl Model 5495 Distributed Power Module 4.7kQ end -of -line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. SILENT KNIGHT by Honeywell • - - V A 1 - - Model 5495 Distributed Power Module Supervision The 5495 supervises a variety of functions including: • Low AC power • Low battery condition • Earth ground fault • Auxiliary output power limit condition • EOL supervision trouble or power limited condition at an output When a trouble condition occurs, the 5495 creates a trouble condition on the host control signal circuits to which it is connected. the 5495 still maintains the ability to be activated by the host control. In addition, the 5495 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. Electrical Specification AC input: 120 VAC at 2 amps Output: 24 VDC at 6 amps lnpurNconiffiguration: Current: Standby Alarm Auxiliary power circuit: Notification circuits: Output configuration: Amps per output circuit: Notification circuit output: CNo. of inp is 75 mA 175 mA 1 4 2 Class A (Style Z) 4 Class B (Style Y) (1 Class A & 2GllaJssB) 3.0 (6.0 a bs total) VDC tal) VDC @ 3.0.amps each, 4l7`kS2 EOL resistor required on>each Class B circuit Input voltage range: 9 - 32 VDC Battery charging capacityj4,33.0 AH Ambient -temp.: 32° to 120° F 0' to 49° C Mech nical �/ Dimensions: 124252'W x�16" H x 3 030.88cmW x40.64 cmfH x 7.6 m) Indicator -Lights AC poweron : Green Batt rouble: Yellow Gro,,und fault: Yellow Aix trouble: Yellow Output troubles (1-4): Yellow Approvals: UL: 864 & 1481 NFPA: 72 CSFM 2`Class B or 2 Class�A r< Model 5495'BIock Diagram /Signal ircuit Output �Si nal Circ' uit Outp Local Fire Control Signal 1 nput Signal 2 input (Optional) 120 VAC Distributed Power Module 5495 Trouble Output (Alternative to notification circuit trouble.) Signal 1 Signal 2 Signal 3 Signal 4 Aux. Power SILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350395 Rev B, 12/05 Copyright © 2005 Silent Knight Technical Data TD450049EN Effective November 2016 Supersedes October 2014 HN Series HS Series ST Series Exceder Strobe, Horn Strobe, and Horn Notification Appliances EIT•N Powering Business Worldwide Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre -wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre -wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Thchnicei Data TD450049EN Effective November 2016 Features • Sleek modern aesthetics • Finger slide switches • Voltage test points • Multiple voltages • 3 Audible settings • 90, 95, 99 dB • Industry leading -8 candela settings on 1 device • Wall: 15/1575/30/75/95/110/135/185 • Ceiling: 15/30/60/75/95/115/150/177 • Universal mouting base • Ceiling and wall • Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, 3.5" octal. & 4" octal. (100mm for international customers) Universal mounting base Contact cover Common base for wall and ceiling with 5 mounting options • Voltage test points for quick troubleshooting and easy spot checking (wall models only) 2 EATON www.eaton.com HN Series HS Series ST Series • Environmentally friendly • Low current draw • Up to 9 models now in 1 appliance draw() • 12/24VDC on a single appliance • Easy to remember model numbers O Patented Note: Please read these specifications and associated installation instruc- tions, before using, specifying, or installing this product. Visit Eaton.com/ massnotification for current installation instructions. General Notes • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range': • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (t 2%) UL 464 (85% UL 1971). • Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements • Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Patented Sync Protocol • Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage • Strobes produce 1 flash per second over the "Regulated Voltage" range Compliance • UL 1971, UL 464, ULC, CSFM, FM • ADA/NFPA/ANSI/OSHA • RoHS Hlu Series HS Series ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 iiii, Technical Data TD450049EN Effective November 2016 24VDC/24FWR 12VDC ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Hom Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Current® at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage iiikHModel Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - 0.282 0.125 0.159 SC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - Regulated Voltage Model Range VDC UL Max Current® at Anechoic 95 dBA 24 VDC 12 VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - Regulated Voltage Model Range VDC UL Max Current® at Anechoic 90 dBA 24 VDC 12 VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ® UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Table 3. Horn Ratings per UL Anechoic Regulated Voltage Model Range VDC 99 dB Model Legend 95 dB 90 dB HN = Horn R = Red HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 Table 4. Specification & Ordering Information Sync w/ DSM or Wheelock Power Model Strobe Candela Supplies 12/24 Mounting VDC® Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMB' HSW 15/1575/30/75/95/110/135/185 X X UMB® HSRC 15/30/60/75/95/115/150/177 X X UMB® HSWC 15/30/60/75/95/115/150/177 X X UMB© Strobes STR 15/1575/30/75/95/110/135/185 X X UMB® STW 15/1575/30/75/95/110/135/185 X X UMB® STRC 15/30/60/75/95/115/150/177 X X UMB® STWC 15/30/60/75/95/115/150/177 X X UMB© Horn HNR X X UMB® HNW X X UMB® HNRC X X UMB® HNWC X X UMB® ,O 12 VDC models feature 15 & 15/75 settings 0 UMB = Universal Mounting Base ST = Strobe HS = Horn Strobe C = Ceiling Mount W = White A = Agent Lettering (strobes only( AL = Alert Lettering (strobes only) N = No Lettering (strobes only) Example 1: STRC = Strobe, Red, Ceiling Mount Example 2: HSR = Horn Strobe, Red, Wall Mount Example 3: HSW = Horn Strobe, White, Wall Mount Example 4: STW-AL = Strobe, White, Wall Mount, Alert Lettering Example: HSR Example: HSWC EATON www.eaton.com 3 Technical Data TD450049EN Effective November 2016 HN Series HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where multi - candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g., ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single -gang, double -gang, 4 -inch square, 3.5 -inch octal, 4 -inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non -synchronized flash -rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. NEVIA Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 Eaton.com/massnotification r 2016 Eaton � All Rights Reserved _ Printed in USA Publication No. TD450049EN Powering Business Worldwide November 2016 Eaton is a registered trademark. All other trademarks are property of their respective owners. 2/7/2019 5:15:00 PM, Administrator, ARCH full blccd D (36.00 x 21.00 Inchcs) FA PLAN ACCEPTED 1:3, Without Comments la As Noted in Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which co nor a,ithorize violations of adopted standards and ordinances, The responsibility for the adequacy of design rests tol6, with the designer. Additions, deletions or 7:evisions to tIlese drawings after is date MI vold this acceptance and will require a ie. -submittal of revised drawings subsequent approval. Frial acceptance is subject to fieid test and inspection by Tne Tukwila Fire Prevention Bureau. Date: 111 By: A-1,- TUKWILA FIR2 DEPARTMENT Peas t cz.-11 205-575-4407 End giye this Fire Permit No. and exact addrtass for shut- down or reztoration approval. ..400010•0111121----dt- NICET Certified FA Level IV #124064 Shawn A. Lehman 8L, Expires 11/1/2020 or s0 PAID FEB CO 2019 TUKWILA FIRE TUKWILA FIRE (IQ 27 k) Firm Name and Address KOT ELECTRIC LLC. 1513 105TH AVE CT E EDGEWOOD, WA 98372 ELITE DRESS & BRIDAL TI No. Revision/Issue Date No. Revision/Issue Date Project Address ,A9257 -1-69t11 SOUTHCENTER PKWY, SUITE A TUKWILA, WA 98188 Sheet Title COVER SHEET Project Name ELITE DRESS SHEET INDEX Date PAGE: DESCRIPTION FA1 COVER SHEET FA2 FIRE ALARM DETAILS FA3 CALCULATIONS FA4 SITE PLAN FA5 FIRE ALARM PLAN . 4 PAID FEB CO 2019 TUKWILA FIRE TUKWILA FIRE (IQ 27 k) Firm Name and Address KOT ELECTRIC LLC. 1513 105TH AVE CT E EDGEWOOD, WA 98372 ELITE DRESS & BRIDAL TI No. Revision/Issue Date No. Revision/Issue Date Project Address ,A9257 -1-69t11 SOUTHCENTER PKWY, SUITE A TUKWILA, WA 98188 Sheet Title COVER SHEET Project Name ELITE DRESS Sheet # FA1 Date 02/05/2019 Scale - - - - 1 SMOKE DETECTOR 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 PIV 6 DUCT DETECTOR 7 MAIN FLOOR SMOKE 8 ALT. FLOOR SMOKES GENERAL NOTES . FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS. INCLUDED WITH FACP. FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS. AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KOT ELECTRIC LLC. EDGEWOOD, WA 253-737-7015 FIRE ALARM SYSTEM INSTALLED BY: KOT ELECTRIC LLC. EDGEWOOD, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD. CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEI077BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS. THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA ABCDE FIRE ALARM LEGEND SYMBOL DESCRIPTION Scale SYMBOL FIRE ALARM CONTROL PANEL FACP NOTES: HEIGHT FIRE ALARM ANNUNCIATOR FAA 14 GAUGE 2 CONDUCTOR (NAC) POWER SUPPLY P.S. (SLC) All WALL MNT. FIRE ALARM HORN/STROBE # INDICATES CANDELA RATING (fCi.I4 CEILING MNT. FIRE ALARM HORN/STROBE INDICATES CANDELA RATING PULL STATION WALL MNT. FIRE ALARM STROBE ONLY # INDICATES CANDELA RATING 1 dl CEILING MNT. FIRE ALARM STROBE ONLY INDICATES CANDELA RATING Ell WALL MNT. FIRE ALARM HORN ONLY 0(1 CEILING MNT. FIRE ALARM HORN ONLY [D FIRE ALARM BELL F FIRE ALARM MANUAL PULL STATION O SMOKE DETECTOR HO HEAT DETECTOR SMDUCT SMOKE DETECTOR 60" BEAM SMOKE DETECTOR BS BEAM REFLECTOR BR 3 DRY FLOW SWITCH M WATERFLOW SWITCH IL1 HIGH/LOW AIR T TAMPER SWITCH POST INDICATOR VALVE PIV INPUT MODULE FOR DUCT DETECTOR M DUCT DETECTOR TEST SWITCH IM INPUT MODULE DUAL INPUT MODULE IM2 e 10 INPUT MONITOR MODULE MEE e Z RELAY MODULE 7 CONTROL MODULE 4.%kn -V y V- CIRCUIT# END OF LINE RESISTOR i 1 ABOVE CEILING DEVICE (WP) WEATHER PROOF (LF) LOW FREQUENCY (N) NEW (E) EXISTING (R) RELOCATE N OTE: NOT ALL SYMBOLS ARE USED IN THESE DRAWINGS 1 SMOKE DETECTOR 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 PIV 6 DUCT DETECTOR 7 MAIN FLOOR SMOKE 8 ALT. FLOOR SMOKES GENERAL NOTES . FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS. INCLUDED WITH FACP. FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS. AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KOT ELECTRIC LLC. EDGEWOOD, WA 253-737-7015 FIRE ALARM SYSTEM INSTALLED BY: KOT ELECTRIC LLC. EDGEWOOD, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD. CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEI077BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS. THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA ABCDE Sheet # IFA2 WIRING LEGEND DEVICE HEIGHT SCHEDULE Scale SYMBOL DESCRIPTION DEVICE NOTES: HEIGHT A 14 GAUGE 2 CONDUCTOR (NAC) OUTDOOR HORN/STROBE 96" (SLC) HORN/STROBE 16 GAUGE 4 CONDUCTOR 80" D PULL STATION (NAC) 48" FIRE ALARM CONTROL PANEL 60" POWER SUPPLY CIRCUIT NUMBER 60" e BELL e 96" ANNUNCIATOR 60" e 1 SMOKE DETECTOR 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 PIV 6 DUCT DETECTOR 7 MAIN FLOOR SMOKE 8 ALT. FLOOR SMOKES GENERAL NOTES . FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS. INCLUDED WITH FACP. FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS. AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KOT ELECTRIC LLC. EDGEWOOD, WA 253-737-7015 FIRE ALARM SYSTEM INSTALLED BY: KOT ELECTRIC LLC. EDGEWOOD, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD. CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEI077BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS. THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA ABCDE Sheet # IFA2 WIRING LEGEND 02/05/2019 Scale SYMBOL DESCRIPTION NOTES: e A 14 GAUGE 2 CONDUCTOR (NAC) B 16 GAUGE 2 CONDUCTOR (SLC) C 16 GAUGE 4 CONDUCTOR (S -BUS) D 12 GAUGE 2 CONDUCTOR (NAC) E 14 GAUGE 2 CONDUCTOR (FPLR) F - # CIRCUIT NUMBER e 1 SMOKE DETECTOR 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 PIV 6 DUCT DETECTOR 7 MAIN FLOOR SMOKE 8 ALT. FLOOR SMOKES GENERAL NOTES . FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS. INCLUDED WITH FACP. FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS. AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KOT ELECTRIC LLC. EDGEWOOD, WA 253-737-7015 FIRE ALARM SYSTEM INSTALLED BY: KOT ELECTRIC LLC. EDGEWOOD, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD. CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEI077BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS. THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA ABCDE Sheet # IFA2 Date 02/05/2019 Scale NOTES: e e e e e ® e e e e e o e e e e e e 0 0 0 ABCDEF GH I SEQUENCE OF OPERA TION MATRIX SCALE: N. T. S. PCi- 7 75 4' 4. 30 75 75 15 15 v v I qI I dl I;o;l ISI IRI FIRE ALARM RISER 4.7kSI SCALE: N.T.S. GENERAL NOTES 1. GRAYED OUT DEVICES ARE EXISTING. .400' fr NICET Certified f FA Level IV #124064 Shawn A. Lehman i)\, g„ct,,,._ ac____,/ 1 Expires 11/1/2020 , 11%4N:411...4m-mr--'4.°.4.°F Firm Name and Address KOT ELECTRIC LLC. 1513 105TH AVE CT E EDGEWOOD, WA 98372 ELITE DRESS & BRIDAL TI No. Revision/Issue Date No. Revision/Issue Date Project Address 16901 SOUTHCENTER PKWY, SUITE A TUKWILA, WA 98188 Sheet Title FIRE ALARM DETAILS Project Name ELITE DRESS Sheet # IFA2 Date 02/05/2019 Scale Standby Hours: 24 Alarm Mins: Derating Factor 1.2 Voltage Drop Warning Threshold % : ,n 1 Volt:, .., %Drop EOL . 2.52 2.52 1.59 1.59 350 355 1.76 -°0.00 0.00 0.00 18.87 19.49 20.40, 20.40 20.40 7.48% 4.45% 0.00% 0.00% 0. 00% Wire resistresistnces are based u pon a n ambient teniperature of 72 degrees F. Because of the min imal d ifference between solid and stranded wire n o differential was made. Project Information Project Name: Elite Bridal TI Prepared By: Shawn Lehman Project ID: 0 Date: 2/5/2019 Ckt. Number: NAC #1 Panel ID: 5495 Ckt:: Name: 5495 Circuit 1 Max Circuit Current: 3 Amps Qty Duce Current Draw Standby 0.000 Each Alarm 0.065 Current Draw Standby :.` 0.000 Total Alarm 0.130 2 Wheelock RSSIRSSP24MCC Strobe (1 Scd) • ; 1 WheelockAS24MCC Ham/Strobe (15cd) ' • 0.000 0.175 0.000-> 0.175 1 wheelotk AS24MCCH Horn/Strobe (177cd) 1 • 0.000 0.560 0.000. 0.560 Unused 1 • 0.000 0.000 ,. 0.000 0.000 0.000 0.000 < Retum To Power Supply Config 1 Edit Device Database Totals 0.000 0.865 Ckt. Number: NAC #2 Ckt. Name: 5495 Circuit 2 :Panel ID: 5495 Max Circuit Curren 3 Amps Qty 1 2 1 1 vice HSCR H5 (3Ocd) CR Strobe (1 cd HSCR H55 (75cd) STCR Strobe (75cd) Current Draw Each Current Draw Total Standby Alarm Standby ' Alarm 0.000 0.000 • 0.000 0.'102 0.061 0.148 0.135 0.000 0.000 0.000 0.000 0.102 0.122 0,148 0:135 0.000 < Return To Power Supply Config Edit Deuce Database Totals 0.000 0.507 Ckt_ Number NAC #3 Ckt. Name: 5495 Circu Panel ID: 5495 Max Circuit Current: Amps Device Unused Current Draw Each Standby Alarm 0.000 0.000 Current Draw Total Standby Alarm 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused • 0.000 0.000 0.000 Unused 0 0 0.0(30 0. 0- 0 0.000 < Return To Power Supply Config Edit Device Database Totals 0.000 0.000 Ckt Number NAC #4 Ckt. Name: 5495 Circuit 4 Panel. la 5495 Max Circuit Current: 3 Am Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused Unused t 0.000 0.000 0.000 0 0.000 0.000 = 0.000 0.000 I Unused 0.000- 0.000 0.000 Unused 0 0.000 0.000 0.0(10 < Return To Power Supply Config Edit Deuce Database Tota Is 0.000 0.000 0.000 0.000 0.000 . ,Number. Auic CktName: 5495 Aux Power Out Panel ID: 5495 Max Circuit Current: 3 Amps Current Draw Each Current Draw Total Standby - Alarrn Standby Alarm Unused 0.000°° 0.000 0.000 0.000 Unused • • -- 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0 0.000 0.000 0_ 0.000 0.000 <Return To Power Supply Config Edit Device Database Totals 0.000 0.000 NICET Certified FA Level IV #124064 Firm Name and Address KOT ELECTRIC LLC. 1513 105TH AVE CTE EDGEWOOD, WA 98372 ELITE DRESS & BRIDAL TI No. Revision/Issue Date No. Revision/Issue Date Project Address 16901 SOUTHCENTER PKWY, SUITE A TUKWILA, WA 98188 Sheet Title CALCULATIONS Project Name ELITE DRESS Sheet # FA3 Date 02/05/2019 Scale riaF� 44) 0 +0 MT 'STC EAA Et& 'Ri4'G. �e Ts+_r� h6 %4Vi p -.pts SITE PLAN SCALE: N.T.S. 2/7/2019 5:45:10 PM, Administrator, ARCH full blccd D (36.00 x 24.00 Inchcs) • SOUTHCENTER PKWY NICET Certified FA Level IV #124064 KShawn A. Lehman Expires 11/1/2020 Firm Name and Address KOT ELECTRIC LLC. 1513 105TH AVE CT E EDGEWOOD, WA 98372 ELITE DRESS & BRIDAL TI No. Revision/Issue Date No. Revision/Issue Date Project Address 16901 SOUTHCENTER PKWY, SUITE A TUKWILA, WA 98188 Sheet Title SITE PLAN Project Name ELITE DRESS Sheet f F'A4 Date 02/05/2019 Scale 2/7/2019 5:45:15 PM, Administrator, ARCH full blccd D (36.00 x 24.00 Inchcs) -"\ 1 in I —AL/ FIRE ALARM PLAN SCALE: 1/4-1'-0" ADJACENT TENANT SPACE M OCCUPANCY I I II I II ! I tr, LU TO PS1-2 4)- A 30 FITTING ROOM 1 15 FITTING ROOM 1 x FITTING ROOM 1 r3.1 15 1 / - A4 TYP. PARTITION HEIGHT - 8' /5' SALE AREA t750 SF $FA TOTAL OCCUPANCY LoAb = 29 OCCUPANTS EXIT \ REGISTEF STAND 1 75 4.7161 PS1-2 EXIT COMMON DELIVERY HALL \ RELOCATEil I 1. \ I I ; I 1,1111! SI (-A TYP. PARTITION.1 PREP AREA 11' :Z=Z:KKI=K= I EXISTG STOREFRONT TO REMAIN D1SPAyS I \ c] ce 3 _3 CO ›— X 3 : f -----i MEN iii :. , .. : : , i:,. EXISTG ADA RESTROOM n----------, . : ;------ - 3 3 3 3---3 I ; WOMEN EXISTG ADA RESTROOM COMMON HALL ADJACENT TENANT SPACE OCCUPANCY L-7 n GENERAL \DIES: 1. TYPICAL CEILING HEIGHT IS 12'. a FITTING ROOM SEPARATION WALLS ARE PARTITIONS THAT ARE 8' TALL. 3, WALL BETWEEN STOCK ROOM AND PREP AREA IS 8' PARTITION. 4, FACP AND NAC PANEL ARE EXISTING. NICET Certified FA Level IV #124064 Shawn A. Lehman Expires 11/1/2020 Firm Name and Address KOT ELECTRIC LLC. 1513 105TH AVE CT E EDGEWOOD, WA 98372 ELITE DRESS & BRIDAL TI No. Revision/Issue Date No. Revision/Issue Date Project Address 16901 SOUTHCENTER PKWY, SUITE A TUKWILA, WA 98188 Sheet Title FIRE ALARM PLAN Project Name ELITE DRESS Sheet 1 FA4 Date 02/05/2019 Scale