PP - 15635 WEST VALLEY HWY - EXTENDED STAY AMERICA - PERMITS AND PLANS
15635 WEST VALLEY HWY ASSOCIATED PERMITS 97-S-151 97-F-131 16-F-072 97-S-151 19-F-167 13-F-077 TUKWILA FIRE MARSHAL'S OFFICE Phone: 206-575-4407 • Email: FireMarshal@tukwilawa.gov 4 CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date 9._l O- -Q Permit # t°l Property Address (5 CtVo i Suite # City TUKWILA Zip Code Name of Facility f-).. Occupied as Owner or Representative * Phone — x Installing Company A ce L i t_ Installing Contractor's Address >o �, CityJ" CoA Ic."\--t-fb-c*e. I ' Installer's Name (PRINT) 3c,SSt_ Phone # yK 7 75- y2.dt License and/or Certificate 14c) « 0°N General Contractor Electrical Contractor FACP Equipment Manufacturer 1 tt .4-(4 Model #"T'C•. 7 This system has been installed tested and operates in accordance with the standards listed below and was inspected by .eg5, On (date)and includes the devices listed on back. Circle all that apply: NFPA 72, Chapte 1 2 4 and/or IFC SEC 907 , NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions Manufacturer's Instructions Other (specify) Tukwila City Ordinance Numbers 2050, 2051 UL Central S do on' or TO- (933-z,77 System is monitored by CO SIGNED 1 Date a^ to - C7 System Firm Installed version Checksum Date Initial program Installation Date Revisions and Reasons Programmed by EQUIPMENT INSTALLED AND TESTED: Control Panel Manual Station Smoke Detectors Heat Detectors Duct Detectors of _ Make/Model of Make/Model of Make/Model of_ Make/Model of Make/Model AN Devices _ of _ Make/Model Audio Devices _ of Make/Model Visual Devices _ of _ Make/Model Auto Door Release _ of _ Make/Model Trouble Indictors _ of _ Make/Model Batteries Readings Battery Full Load Charge Generator _ HVAC Controls _ Fire Alarm Dialer l Monitored by( Q Annunciator of of of) Make/Model Make/Model Make/Model Wiest c i l Cr -7 Y00- Cr33-c47 7 of Make/Model 0 Sprinkler System. (Fire Alarm connections only) Water Flow Sw. Valve Tamper Sw. PIV Elec. Alarm Bell of _ Make/Model of _ Make/Model of Make/Model of Make/Model Automatic time Delay of Water Flow Alarm seconds. None Installed Do you meet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes No Test of alarm System on emergency power, satisfactory? Yes _ No Test Witnessed by Title Comments: Date Fire Alarm Certificate.doc Revised: 6/17/14 TFD FP Form #110 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 101-F*- K(,7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 6e,ia?ed 5k Type of Inspection: H La r44 Address: �y Suite #: %�' -63� to /KL`c,( I Contact Person: JeSS�. Special Instructions: 1 1 Pre -Fire: Phone No.: tr• r- e( 7z/ Approved per applicable codes. riCorrections required prior to approval. COMMENTS: 1WiL CeAf'1Mw4ir_o1iar) TraiRRt7- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: ` Occupancy Type: Inspector: J,'\ \ —.(A3st Date: 'Z' 10 It Hrs.: ' $100.0 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 CORRECTION NOTICE/REINSPECTION FEE Inspector: T g5 1 Permit number: TUKWILA FIRE DEPARTMENT/FIRE PREVENTION BUREAU 444 Andover Park East, Tukwila, Wa. 98188 Office: 206-575-4407 Fax: 206-575-4439 Business Name:Type ev- of Inspection: /e07 Location Address:Taw //buy Date : oz Contact Person : 2�� %6(f Phone N . : �i/ K ACTION REQUIRED .ZilAN QINR'I ' � cH�"�J/W'���C., >,29 /��ry/k.to_ 7,-/04,14 k aLSGIA iit (AWN f�M-fie' 44 .(7,- , ,/, , i'ee aii4 .-z,41/4,0 .,- QAC' C2Ni ' 0 7Artk CORRECTION OF .H ABOVE ITEMS ARE REQUIRED BY : l60) �/ fd0 FAILURE TO CO L MA RESULT IN THE ISSUANCE OF A CRIMINAL CIT ICKET. Signature: i / Billing/Mailing Address : Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Reinsp Fee2.doc Revised 3/26/10 T.F.D. Form F.P. 100 /' CORRECTION NOTICE/REINSPECTION FEE P Ins ec�tor: ' Permit number: TUKWILA FIRE MARSHAL'S OFFICE Office: 206-575-4407 Fax: 206-575-4439 Email: Fire Marshals tukwilawa.2ov Business ea -t- Type of Inspection ^ 5 �i�r t �S le Location Address: /35"-- +/v'�( l 5 b Date : 4.../1,z h Contact Person :A•1/4 ---Phone ✓ t c,6-. fr G)f-1C-JT 1`l.,,y6 &e No.. /•//�_ ACTION REQUIRED : 11(�vLJ v by se6-7.77 of /UY-- I� C p4. . gI 6 k S GorL2&----7z0 rJ Aki-1 LE w .-1- a 1j if- /0 b G CF/I") - if-tA, b ✓ t c,6-. fr G)f-1C-JT 1`l.,,y6 &e c'N G` 6 _ P -/\J £Z ( S 4-P0y�- Z �^ /$9,/ 6 ,-.0.73 ,5-41-61, 1» Te -a, 7 - 11-66\/6--- r 7 4.--14 GOA zr26ft"9 8 -AA CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY : FAILURE TO COMPLY MAY RESULT IN THE ISSUANCE OF A C Signature: itjlAv Billing/Mailing Address : MINAL CITATION/TICKET. Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Reins') Fee2.doc Revised 6/17/14 T.F.D. Form F.P. 100 4411W44 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION King Co. Assessor's Tax No.: Site Address: / 5 63_CW 1 VA\\ Hwy Suite Number �5� 1Z6� \ Floor: Tenant Name: S-7 /NY CA ��i�4-'- '' New Tenant? ❑ - Yes ❑ - No Property Owner's Name: Mailing Address: 1 C 6 3C \A/ V eA.\ey \y, City State 61(61 Zip CONTACT PERSON -if there are questions about the submittal. / Name: G\ & kssoeLen L4)(Ye 5 Day Telephone: Wb 2 'e(2,440 ^l-� r'CC .�7- LL Company Name: G7��-Ow` �k� 1 � S � � , Mailing Address: 37 /6. r -c [/V ur4L, S 1/4., e `oZ 1nvi,Jr '` 4a 002 City State Zip E-mail Address: Fax Number: Contractor's City of Tukwila Business License number: Total number of new/relocated devices or sprinkler heads: x 3 Valuation of Project (contractor's bid price): $ ,, Scope of Work (please provide detailed information): 4L -X C/( 3 5i l 51-4v10 e co 1 "-t("oy `10 0 , co wt. Azke, 3 fi b' o"`ky 4204 -- Rot, wt gorRoc,wt 5 0-5 ` l26 1127 PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature ! Print Name: C\* Sit vr)Lf z_ "� �PL $ Plan Permit App.doc 8/22/14 Day Telephone: Date: /70 C� 7,0 6 , -2- 141 , 1q0-7 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION, Applications and plans must be complete in order to be accepted for plan revi •i **PLEASE PRINT** Site Address:15635 West Valley Highway Tenant Name: Extended Stay King Co. Assessor's Tax No.: Suite Number: Floor: New Tenant? ❑ - Yes El - No Property Owner's Name: Extended Stay America LLC Mailing Address: 15635 West Valley Highway Tukwila WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Jesse Houfek Day Telephone: 425-218-4721 Company Name: AlarmTech Inc Mailing Address: PO Box 186 Mountlake Terrace WA 98043 Jesse@alarmtechincorporated.com City State Zip E-mail Address: Fax Number: 140609 Contractor's City of Tukwila NICET III number: Business License number: Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 1500 Scope of Work (please provide detailed information): Install a new fire alarm cellular communicator PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID BUILDING OWNER.OR AUTHORIZED AGENT: AUG 12 2319 Date: 7-30-19 Signature: TUKWILA FIRE Print Name sse Houfek Day Telephone: 425-218-4721 Plan Permit App.doc 8/22/14 TFD FP Form 8 �/�� f ��/ SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** , / / /74,.King Co. Assessor's Tax No.: Site Address: /$^ ur tries-1V� l (9 Suite Number: Floor: Tenant Name: &Xk4c cA ‘C-7 ,AAAe '(es New Tenant? ❑ - Yes - No Property Owner's Name: /DAite,S e -X v' /4 S' Mailing Address: / City State Zip CONTACT PERSON -if there are questions about the submittal. Name:I _S (A ) Day Telephone: Z�.? Y'S7 `7/51 Company Name: /7643 VP C-7' A-66 S—E-C c.✓1-/ rye S' -- 1�� - Mailing Address: /cold c�/- C'. i -v vu i/Z04 (/✓41 < <T F / City / State Zip ' E-mail Address: G ✓SIO CCC -�,, N�`7- Fax Number: Zo— ' 7/ `7 z 32- Total 3ZTotal number of new/relocated devices or sprinkler heads: 2 Valuation of Project (contractor's bid price): $ 27v Scope of Work (please provide detailed information): /leo _ 7P CO.A./1 (A Al (C -*r 7`o Fisc GiAr-,..4 7%d/ p4fru2 PERMIT APPLICATION NOTES Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extemion shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OAUTHORID AGENT: Signature: Print Name: A44,0_46– A / c574¢1"-) Date: 3 -Or l� Day Telephone: 2 3 3(S /y 3 7 Plan Permit App.doc 1/2/13 TFD FP Form 8 t.. 1' City of Tukwila' Fire Department June 20, 1997 Smith Fire Systems Sprinkler Plan Review John W. Rants, Mayor Re: Homestead Village - 15635 West Valley Highway Thomas P. Keefe, Rre Chief Approval of this project is conditional upon completion of the following items: 1) Follow items 1, 4, 5, 7 and 8 of the W.S.R.B. review dated June 13, 1997. 2) No light hazard in the attic. 3) Bathroom fixtures shall be noncombustible. 4) Bracing shall comply with N.F.P.A. 13, 1996, Table 4-14.2.2.1. 5) Riser alarm piping per N.F.P.A. 13, 1996, 2-9.4, 2-9.5. 6) Elevator sprinklers shall be on separate valve. 7) Provide as-builts including the above corrections. Headquarters Station: 444 Andover Park East • Tukwila, . ':ington 98188 • Phone (206) 575-4404 • Fac(206) 575-4439 Project Name: Fire Alarm Submittal Extended Stay Residences (9730) 15635 West Valley Highway Tukwila, Washington 98188 Submitted by: Granite Guard, LLC Quincy, MA Date: 14 February 2013 100 Newport Avenue Extension Quincy, MA 02171 617.745.5005 E Mail:11smith@granitenet.com Sequence of Operation Upon Activation of an Alarm of Fire the following actions will occur: 1. All notification appliances will sound and produce a visual notification in a synchronous manner. 2. The location of the alarm of fire will show on the main fire alarm control panel, this will be done by the most recent alarm of fire showing first and each event there after. 3. The system alarm of fire will be transmitted via Digital Communicator to a UL Listed Central Station. 4. The system will transmit an Alarm of Fire to the Central Station via the IP Communicator. 5. The system will not be silenced until the Local Fire Department Representative authorizes same. Upon Activation of a trouble signal the following will occur: 1. Upon activation of trouble in the main fire alarm control panel the trouble piezo will activate and stay active until it is manually silenced by an authorized representative of the property. 2. The Central Station Dialer will be activated and will notify the Authorized Building Representative to respond and an authorized representative of the Alarm Service Company. 3. The IP Communicator will transmit to the Central Station a signal and the proper representatives will be notified. 4. The audible notification at the panel will resound every 24 hours until the incident is cleared. Again, the sounder must be manually silenced by an authorized representative. Upon activation of a supervisory signal the following will occur: 1. Upon activation of a supervisory trouble signal in the main fire alarm control panel the trouble piezo will sound and stay active until it is manually silenced by an authorized representative of the property. 2. The Central Station Dialer will be activated and will notify the Authorized Building Representative to respond and an authorized representative of the Alarm Company. 3. Upon activation of a Supervisory Signal a signal will be sent to the Central Station and the proper representatives will be notified. 4. The audible notification will resound every 24 hours until it is manually silenced by an authorized representative of the property. • O z O w 0 co ,0'104 d1 4:6 4g44s44,roA s oa_,fid 40,10°,s^B/4r %q °yo4440 440/ sbs8�'o:0004o :001.40 zS/s °/ o/ ,/0 ss00/04, 2 gars y Jf as/o/ woo. s/ 44@ gars 8/°Olt,/ 74' 01 r1 si /O�a 4o) r@4@ qn q/4'o� @ti/ge/gn�;`4s4�,� * j046 s/a 414,8 04@/0 4V �nS /x$0.44 0010,1 0 1@8 z s4@90o 4 @4. 2@4@1�o/s A@W Ez.°4@, rs4@ssg/q/°s /s O Cpo41(nrJJ/e4 .4o 4n1+@Z isos ,� %411:14. tian p,@0n1jbW°4,�o n/ob �a 401 s@8nso�wO° +n1°bo�/4/@s4@@/q/p'*10‘..V1@r4ee@b o14�°bma vo, _ . 0 4190f /s er 4 %e 4144o* /1'2040 4 (- Nob, • x XXXXX XXXXX 0 X SYSTEMS INPUTS XXXXXX X X xxxxx XXXXX a 0 0 0 07 z x x X X X X XXxx x xX Xxxx XXXX XXXX 0 2'. > LL `«�+ m 8 i& r°° dxa "8 'a°-xC°0xE oDd�3Y.'2�aLEa°po`Ndd2, o co -/ i7 d >=01 y r L lL 0 w 2 .. > a lL Z W m m ''- w N M V N t0 POD 01 C e- N M a 1Q i0 P CO 01 DSC T LinkTM Universal IP Alarm Communicator TL300 The T Link universal IP alarm communicator (TL300) is a valuable addition to the T Link family of Internet/network alann communicators. Capable of communicating with any control panel (including third - party manufacturers) that uses the Contact ID format, the simple -to -install TL300 saves end-users money by taking advantage of their existing IP networks and security equipment to create fully supervised security solutions between protected premises and central monitoring stations. This method provides flexibility and an always -on, two-way line of communication. The TL300 communication stream is small and requires only a limited amount of network bandwidth. This ensures that the integrity of the data being transferred never becomes compromised. To reduce security risks, the module utilizes industry-leading, 128 -bit AES encryption, polling and hardware substitution protection. Product Features: ► Compatible with any control panel that uses the Contact ID format I. 2 -way, always -on IP communication • Works over local LAN/WAN network or the Internet ► 128 -bit AES encryption (NIST approved) ► Supports DHCP (dynamic IP addresses) ► Reports events to 2 different receiver IP addresses ► Polling and hardware substitution protection ► Low network bandwidth requirements ► Compatible with 10/100BaseT networks ► 4 on -board programmable zone inputs (expandable to 12 using PC5108 zone expander module) ► 2 programmable voltage outputs ► Programmable through the panel keypad or T -Link Console software ▪ UL AA High -Line Security, ULC Level 3/4/5 and CE listed Contact your DSC distributor www d,c, cum 1 305- 700.3000 MISC tLICO /1-u, DSC T-LinkTM Universal IP Alarm Communicator TL300 How it Works The TL300 connects directly to the telephone output of a control panel and simulates a telephone connection, providing a TCP/IP connection that sends predefined Contact ID codes to the central monitoring station. Value Added To ensure dependable and timely event notification, the TL300 is capable of reporting to two different receiver IP addresses—a back-up feature that allows communication to continue in the event one of the IP addresses is inaccessible. The module can also be programmed to communicate events to two different e-mail addresses. These e-mail addresses can be associated with a personal computer, pager, enabled mobile phone or PDA. Flexibility Programming the TL300 can be accomplished locally using the DSC LCD5500 keypad or the T -Link Console software over the IP network connection made directly to the communicator's Ethernet port. By interfacing to the module's four on -board programmable zone inputs, the TL300 can be configured to operate as a stand-alone communicator for interfacing existing third -party control equipment. Full two-way communication with the TL300 and the Sur -Gard System III receiver's IP line card, the SG-DRL3-IP, allows for alarm reporting as well as remote diagnostics. Secure Communication The TL300 utilizes industry-leading 128 -bit AES encryption, polling, hardware substitution protection and application-specific hardware to help eliminate security risks. Because the module's communication stream is minimal and draws only small amounts of network bandwidth, data transfer remains timely and accurate. Ordering Information: T Link TL300 Universal IP Alarm Communicator PC5108 Zone Expander Module Distributed by: Compatibility The TL300 is compatible with any control panel, via the Ring and Tip connection, that uses the Contact ID format and follows the Contact ID specifications of 40 ms/60 ms on/off time. Direct trigger inputs of the TL300 can be controlled by outputs on any control panel. Central station IP receiver: • Sur -Gard System III with SG-DRL3-IP line card Please refer to applicable manuals for further details. Specifications Dimensions 3.25" x 5.25" (83 mm x 133 mm) Input Voltage 12 Voc Current Draw 250 mA (275 mAwith PGM or PC5108) Operating Environment 32° to 120° F (0° to 49° C) Relative Humidity 5% to 93% Ltra•2 • S. c1.n.y DSC For product information www.dac.com Product specifications end availability subject to change without notice. Certain product names mentioned heroin may be trade names and/or registered trademarks of other companies. C2006 1O%'t t DSC - Product Approvals Page 1 of 2 DSC' A rneoi tiaM1Modelal C41.108AW North America (Change Region] 1 English (Change Language] Security Professional Login search r+get ad Y.ed: itrs Products Industry Solutions Technical Library News and Events About Us Contact Us Technical Library United States Product Approvals View Product Approvals for a different region? Select a Continent / Country /J • Panels, Keypads and Modules Sensors and Accessories 63 Communications Product HSPA (3G) Wireless Alarm Communicator - IMPASSA 3G2056 HSPA (3G) Universal Cellular Alarm Communicator 303070 HSPA (3G) Universal Wireless Commercial Fire Alarm Communicator 3G3070 -CF Central Station Printer for SG Receivers DPU -414-306 Central Station Printer for SG Receivers DPU -414-308 GPRS Cellular Alarm Communicator GS2080/GS2060SM GPRS Cellular Alarm Communicator GS2065 GSM Universal Wireless Commercial Fire Alarm Communicator GS30654CF GSM Universal Wireless Alarm Communicator GS3055-IG/IGW GS3055•IGIIGW GPRS Universal Cellular Alarm Communicator GS3060 POTS Line Card For SYSTEM III SG -DRL3STD SG-DRL3STD SG -SYSTEM I/SG-SYSTEM I -IP Dual Phone Line with Optional IP Receiver SG-System_I SG -SYSTEM II Single -Line IP Receiver SG-System_il Virtual Receiver SG -SYSTEM III SG -System 01 SG -System IV System IV T -Link IntemeUlntranet Alarm Communicator TL260 T -Link IntemeUlntranet Alarm Communicator TL280 Internet and HSPA Dual -path Alarm Communicator TL2603GR Internet and GPRS Dual -path Alarm Communicator TL26OGS T -Link IntemeUlntranet Alarm Communicator TL260R UL Residential Burglary d UL FCC UL Residential Part Commercial Fire 22 Burglary CSFM NYFD Listing Certificate UL FCC Part 68 Commercial (ACTA) Fire Telecom 0 0 a0 a 0 yes Ili 0 1' Q 0 T -Link Internet/Intranet Alarm Communicator 0 0 TL286 d d 0 0 yes d PTCRB NIST Certification Validation yes yes yes 0 d http://www.dsc.com/index.php?n=library&o=approvals 2/14/2013 TG7-FS LTE TELGUARD COMMUNICATOR FOR COMMERCIAL FIRE APPLICATIONS ARCHITECTURAL AND ENGINEERING SPECIFICATION TELGUARD PAID kU3 12 2319 TUKWILA FIRF Table of Contents 1 General 3 1.1 Purpose 3 1.2 Scope 3 1.3 Warranty 3 2 System Summary 4 2.1 Unit Description 4 2.2 System Overview 4 2.2 Approvals 4 2.2.1 UL Listings 5 3 Functional Description 6 3.1 Signal Transmission from FACP to Central Station 6 3.1.1 Dialer Capture 6 3.1.2 Cellular Transmission 7 3.1.3 Delivery to Central Station 7 3.2 Link Supervision for Sole Path installations 7 3.2.1 NFPA 72 requirement 7 3.2.2 Link Supervision 7 4 Physical Description 9 4.1 Metal Enclosure 9 4.2 PCB 9 4.2.1 I/O Connections 9 4.2.2 LED Display 10 4.3 Accessories 11 4.3.1 Included with TG-7FS LTE 11 4.3.2 Optional Accessories 12 5 Sole Path Installation 13 5.1 Power Up Requirements 13 5.2 Signal Strength Requirements 13 5.3 Communication and Supervision Requirements 14 5.4 Other UL Installation Requirements 14 5.5 Wiring Diagram 15 1 General 1.1 Purpose When preparing a specification or quotation for the use of a Telguard cellular device in a commercial fire application, it may be necessary to supply a detailed functional description of the equipment. The architectural and Engineering Specifications presented in this publication cover such information for the TG-7FS LTE models— indiscriminate of carrier variance—and are intended to be used for this purpose as required. 1.2 Scope Although the hardware is slightly different, this Architectural and Engineering Specification document contains detailed functional description for the following Telguard units to work in conjunction with FACP systems with DACT connections: • TG-7FS LTE for AT&T Wireless (Model No. TG7LAFO1/TG7LAF02) • TG-7FS LTE for Verizon (Model No. TG7LVF01/TG7LVF02) 1.3 Warranty Telguard sells its hardware through authorized distributors. As such, Telguard has a responsibility to repair or replace (our option) inoperative units for up to a specified time from date of manufacture. The warranty period is agreed upon by the distributor upon purchase. This excludes damage due to lightning or installer error. Unauthorized modifications void this warranty. Telguard is not responsible for incidental or consequential damages. Liability is limited to price of unit to the distributor. 2 System Summary 2.1 Unit Description The Telguard TG-7FS LTE is a line of digital cellular radio alarm transmission devices used to provide the following three methods of communications for FACP units via a cellular network: • Sole path (Cellular Transmission Only) • Primary path (Cellular Primary & Telco Backup) • Back-up path (Telco Primary & Cellular Backup) 2.2 System Overview Depending on the configuration (determined at time of installation), the FACP will use the TG-7FS LTE as sole, primary or back-up (secondary) transmission path to deliver alarm messages. When it is configured as a backup, it will provide transparent access from the FACP to the central station. When transmitting an alarm signal using the cellular path, the Telguard obtains its data from the alarm panel by way of a Telco line interface. The Telguard will obtain all alarm signal information including monitoring station phone number, account number and all zones for every alarm transmission. The Telguard handshakes with the FACP causing it to transmit the alarm data. The Telguard encodes the alarm data and transmits to the Telguard Communication Center (TCC) over the digital cellular network. The TCC performs a function similar to a central station receiver and issues the transmission acknowledgement when the last message in the transmission is received. After decoding and reformatting, the alarm signal is routed to the appropriate alarm company monitoring station for action. In a cellular back up alarm installation, the incoming Telco line is connected from the premises' RJ -31x jack to the Telguard and then from the Telguard's RJ -45 jack to the alarm panel in the normal fashion. Two programmable System Trouble Condition (STC) relays provide supervisory trip outputs for connection to the FACP's trip zone input terminals in order to provide a Telguard trouble signal. Additionally, automatic self -test and remote query signals are transmitted exclusively over the cellular network with all Telco line and cellular monitoring, switching and supervisory functions built in. No extra modules are required. The Telguard TG-7FS LTE has its own power supply which keeps the Telguard battery charged. 2.2 Approvals • UL: Underwriters Laboratories Inc • ULC: Underwriters Laboratories of Canada • CSFM: California State Fire Marshall • UL 864: Standard for Control Units and Accessories for Fire Alarm Systems • UL 365: Standard for Police Station Connected Burglar Alarm Units and Systems • UL 1610: Standard for Central -Station Burglar -Alarm Units • UL 985: Standard for Household Fire Warning System Units • UL 1023: Standard for Household Burglar -Alarm System Units 3 Functional Description 3.1 Signal Transmission from FACP to Central Station The path of a signal from the FACP to the Central Station receiver through the TG- 7FS LTE unit has three main stages: 1. Local capture of the signal: Using dialer capture technology 2. Data delivery to the TCC: By means of the carrier of choice 3. Delivery of the signal to the Central Station: Through a choice of IP or PSTN connection 3.1.1 Dialer Capture The TG-7FS LTE unit has a patented integrated interface that allows digital dialers to dial into the unit using the following specifications: • Line voltage: -30 Vdc into standard telephone device when on hook. • Dial tone: Precision 350 + 440Hz +/- 1%. 10 digits dial out capability. • Mode: Loop start only. 25mA +/-10% off -hook. As long as the TG-7FS LTE unit has a proper connection to the wireless network, it will provide a dial tone for the FACP to use. Once the FACP has dialed in, the TG-7FS LTE will interact with the panel by providing handshakes and kiss -offs, similar to a Central Station receiver. Provided that the alarm data received is valid per the alarm format protocol, the TG-7FS LTE will capture the message and pertinent information for delivery, while the FACP will be satisfied with the received kiss -off. If an invalid format, or invalid data is captured, no kiss -off will be provided. Compatible formats for the TG-7FS LTE units are: • Pulse Formats (Hexadecimal account numbers can be used): o 3+1 pulse; 10pps, Double Round, 1400 Hz ack o 3+1 pulse; 20pps, Double Round, 2300 Hz ack o 3+1 pulse; 40pps, Double Round, 2300 Hz ack o 4+2 pulse; 20pps, Double Round, 1400 Hz ack o 4+2 pulse; 20pps, Double Round, 2300 Hz ack o 4+2 pulse; 40pps, Double Round, 2300 Hz ack • Contact ID (Hexadecimal account numbers can be used, 4 or 10 digits in length) • Modem Ile/II1a2/4 (Hexadecimal account numbers can be used, 4 digits in length) • SIA2 (SIA -DC -03 level 2 release at 300 baud) • Sonitrol • DMP 3.1.2 Cellular Transmission Once the signal is obtained by the TG-7FS LTE, it is encrypted (128 -bit AES) and packetized for digital delivery via the cellular network. Depending on the version of the TG-7FS LTE unit used (Verizon or AT&T), the carrier of choice will be used. All transmissions between the TG-7FS LTE and the TCC will occur via the best available technology at the time, with data sessions being the primary delivery path and SMS being the secondary option. The TG-7FS LTE can work on different bands depending on the carrier of choice: • TG-7FS LTE for AT&T supported bands: 3G B2/B5, LTE B2/B4/B5/B17 • TG-7FS LTE for Verizon supported bands: LTE B4/B13 Similar to the way a central station receiver operates, the TG-7FS LTE will not be satisfied until there is an acknowledgment of receipt from the TCC. If acknowledgment is not received by the TG-7FS LTE, a failure will be created and annunciated via suppression of the dial tone. 3.1.3 Delivery to Central Station After the TCC receives the data, it will process for its delivery. Based on the subscription options chosen during the registration of the TG-7FS LTE, the TCC can either use the captured phone number and account number to deliver the signal or use a predetermined phone number and account number to redirect the signal. A third option that is available to companies that have set up a connection with a Central Station ahead of time is to use IP delivery rather than POTS to send signals to Central Station. The TCC can deliver signals via IP using the Fibro protocol (for Contact ID and SIA formats) to Surgard receivers, as well as using DMP protocol to send to DMP receivers. Whether using POTS or IP for delivery, the TCC uses an acknowledgment -based retry sequence, where it requires receiver acknowledgment. 3.2 Link Supervision for Sole Path installations 3.2.1 NFPA 72 requirement The TG-7FS LTE unit provides a feature known as "Link Supervision" that complies with NFPA 72, editions 2010-2016 for use a sole path communicator. Link Supervision is a feature by which the TCC checks the unit's connectivity and will create a signal to be delivered to the Central Station if a disruption in service is discovered, lasting 5 minutes (per 2010 edition requirements) or 60 minutes (per 2013 and 2016 edition requirements). 3.2.2 Link Supervision Link Supervision must be enabled from the online portal. It will reprogram the device to initiate check-in signals over the data network, at a frequency that is much higher than the disruption timeout (5 or 60 minutes). If the TCC detects that there has been no communication for the predetermined disruption timeout, it will create a signal (customized during registration) that will be delivered to the Central Station. Once the check-ins resume, a restoral signal will be created and delivered as well. The check-in signals are between the TG-7FS LTE and the TCC and are therefore not visible to the FACP or the Central Station. 4 Physical Description 4.1 Metal Enclosure • Paint: Red Urethane • Locking Mechanism: Zinc die cast lock, 90° turn • Physical Size: 11.4" x 7.75" x 3.3" (290mm x 197mm x 84mm) • Shipping weight: Approximately 5 lbs. 4.2 PCB The TG-7FS LTE unit has I/O connections for communication and power, as well as LEDs to display device status. 4.2.1 1/0 Connections • Antenna port: TNC female connection, 50 ohms • RJ connections: Two RJ -45 connectors. Gray jack from communication from the panel. Black jack for pass through to incoming Telco (not applicable to sole path) • Pin connectors and terminal blocks: There are four sets of pins, with three available terminal blocks. o DC-GND pins: 6.2V-16VDC in. To be used if receiving power from an FACP with an auxiliary output within that range. o STC and Trip In pins: There are two pairs of STC pins. STC 1 acts as a Normally Open relay that will trip on a programmed Telguard failure, whereas STC2 will trip as a Normally Closed relay. There is also a pair of Trip Input connections labeled as Trip and Gnd, which can be optionally used to monitor a dry contact device, with the capability of sending an event to Central Station or provide customer notification on that trip closure/restoral. o Battery pins: There is a set three pins labeled as BATT, with only the outer pins functional and labeled as - and +. This is an alternate connection for the battery, with the same functional specifications as the battery connector. o AC pins: There is a set of two pins for the AC Adapter to connect to. Polarity is not labeled because it is AC voltage • Battery Connector: There is a VHR-2N connector that is keyed to fit with the provided battery harness. Polarity is not labeled as the battery harness can only fit in a specific way. 4.2.2 LED Display LED Symbol Color Pattern Indication LED 1 Activation GreenOff Solid On Unit is activated at TCC and enabled Unit not activated at TCC (and disabled) 1 Flash* Unit is disabled LED 2 STC (System Trouble Condition) Red Off All OK 1 Flash* System Trouble Condition - Low/Missing AC Power 2 Flashes* System Trouble Condition - Low/Missing Battery and/or Battery Charger Failure 3 Flashes* System Trouble Condition - LFC 4 Flashes* System Trouble Condition - NSC 5 Flashes* System Trouble Condition - RFC 6 Flashes* System Trouble Condition - DTF 7 Flashes* System Trouble Condition - PPF LED 3 Mode Yellow Off FACP idle (Telguard is primary or Sole Path) Flash FACP off -hook (cellular mode) On FACP idle (Telguard is backup) LED Symbol Color Pattern Indication LED 4 Acknowledge Red Solid On Waiting for acknowledgement from TCC Off Idle state 1 Flash* When flashing with LED 1, unit has failed activation LED 5 Radio Green Off Telguard initialized On Telguard initializing with cellular network Flash (1 sec) Radio receiving message Flash (2 sec) Radio sending message Flash * (2 flashes / 6 sec) Link Supervision Mode LED 6 Not used LED 7 Trip Input Green Solid On Trip Input activated Off Trip Input not activated or restored LED 8 AC Power Red Solid On AC power connected to unit Note: * means that the LED pattern will repeat until condition clears. 4.3 Accessories 4.3.1 Included with TG-7FS LTE • Cellular antenna: 8in, 50 -ohm nominal, omni -directional LTE antenna with knuckle and male TNC connector. 2dBi gain. • Antenna cable: 12 -ft RG -58 UL approved cable in PVC jacket with 50 -ohm TNC male connector and TNC female bulkhead. • Mounting bracket: 90° angle bracket with .566in-diameter opening for TNC connector. • RJ cord: 7 -ft RJ -45 plug -to -plug flat modular cord with PVC outer jacket. • Battery harness: 20in battery cable assembly with VHR-2N connector on one end and two quick connect connectors on black and red 18ga wires. • Enclosure key lock. • Terminal blocks: Pluggable screw terminal blocks, 3.5mm pitch. Set of 6-, 3-, and 2 -position blocks. • Transformer: UL Listed 12VAC 800mA. 4.3.2 Optional Accessories • ACD -35 antenna cable: RG -8 UL approved cable in PVC jacket with 50 -ohm TNC male connector and TNC female bulkhead. 35ft in length. • ACD -50 antenna cable: RG -8 UL approved cable in PVC jacket with 50 -ohm TNC male connector and TNC female bulkhead. 50ft in length. • ACD -100 antenna cable: RG -8 UL approved cable in PVC jacket with 50 -ohm TNC male connector and TNC female bulkhead. 100ft in length. • HGDL-0: High gain directional LTE antenna, wideband 690-2700MHz, 50 -ohm. U -bolts for up to 1.75" pole -mount outdoor use. 8-10dBi. 11.575" x 8" x 2.375" (294mm x 203mm x 60mm). Type -N female connection, comes with adapter to TNC • EXDL-0: Omnidirectional LTE antenna, 698-960MHz, 1700-2700MHz, 50 -ohm. No ground plane, 3dBi. 3.45" x 1.45" diameter (88mm x 37mm). Type -N female connection, comes with adapter to TNC. 5 Sole Path Installation 5.1 Power Up Requirements The TG-7FS LTE unit must comply with the NFPA 72 requirements which state that the unit will have a secondary power source besides the main power source, that will allow it to go remain uninterrupted for 24 hours at the end of which period it should be able to handle 5 minutes of signal transmission on the secondary power source. While for primary power source, the provided transformer is expected to be used, the TG-7FS LTE units do not come with a battery included. However, the following consumption rates are to be used to calculate the size of the battery required. • 12VDC: 40mA (idle with link supervision enabled), 160mA (transmitting) Note: For a UL approved installation, the transformer and connections must be protected. A UL Listed pull box must be used in conjunction with a UL Listed outlet box and receptacle. Same guidelines that apply to the FACP power supply installation should apply here. 5.2 Signal Strength Requirements It is recommended that the signal strength during the time of installation follows our guidelines to reduce the amount of perceived network issues. Having a lower signal strength than recommended may result in a higher number of incidents as it is the nature of the cellular network to fluctuate in quality and bandwidth. RSSI Value LED's Lighted RF dBm No SVC LED 5 = slow flash, LED 4- 2 = off n/a 1 LED 5 = on, LED 4-2 = off s -111 11 LED 5 = on, LED 4 = slow flash LED 3-2 = off >_ -110 2 LED 5-4 = on, LED 3-2 = off >_ -100 (Minimum signal strength required when Telco is involved) 21/2 LED 5-4 = on, LED 3 = slow flash LED 2 = off >_ -90 (Minimum signal strength when used as a Sole Path) 3 LED 5-3 = on, LED 2 = off >_ -80 31/2 LED 5-3 = on, LED 2 = slow flash >_ -70 4 LED 5-2 = on > -60 Approved accessories as previously listed can be used to relocate or change the type of antenna used. 5.3 Communication and Supervision Requirements If using the TG-7FS LTE unit as the sole path of communication, it will be necessary for the TG-7FS LTE unit to provide dial tone to both Telco connections on the panel, unless one can be disabled. To do this, the Tip and Ring connection on the FACP must be connected in parallel for both Telco connections. As far as supervision of the TG-7FS, there are two System Trouble Condition relays that can be used to locally annunciate to the panel of any issues, as programmed during registration. However, the TG-7FS LTE will also announce through the suppression of the dial tone to the panel of any issues caused by No Service or Radio Failure conditions. Note: Because a low/missing battery or low/missing AC power on the TG-7FS LTE unit will not results in any other type of annunciation, at least one STC relay should be connected to a zone on the FACP. 5.4 Other UL Installation Requirements Household Fire Household Burg/Fire Combination Commercial Fire Optional Optional Required AC transformer lines in flexible conduit. Required Required Required AC transformer plugged into un - switched outlet. Optional Optional Required AC transformer plugged into dedicated branch circuit. Optional Optional Optional Enclosure Tamper Switch connected to 24-hour circuit. Optional Optional Required Antenna cable in flexible conduit concealed or covered by motion detector. SPECTRAIert, Series Horns, Strobes, and Horn/Strobes SYSTEM SENSOR A Division 111 I'ittwac 3R2S Ohio Avenue, St. Chdrie,, 11. 60171 1-8110-SI:A'SOK2 (736-7672), Fav 630-377-6.195 http:i,htunl'.s' str•mscnynr.rom Features • 24 volt strobe models: 15, 15/75, 75 and 110 candela • 12 volt strobe models: 15 and 15/75 candela • Horn models operate on 12 and 24 volts • Low current draw: reductions as high as 45 % • Two field selectable/reversible horn tones - 3000 Hz Interrupted - Electromechanical • Field selectable/reversible high -low dBA output on horn (low output on 24 volt models only) - 101 peak dBA @ 10 ft. high output* - 96 peak dBA @ 10 ft. low output* • Field selectable/reversible temp 3 pattern or non -temp 3 continuous pattern on horn • Horn/strobe can be wired either in tandem or independently Specifications • Universal mounting plate included with each unit • One screw mounting of strobe and horn/strobe to mounting plate • SpectrAlert strobe and horn/strobe take up zero room in the back box. • Single gang mounting without the use of a mounting plate (hom model only) • Self-contained screw covers • Aesthetically pleasing design • Synchronize horn and strobe with Sync•Circuit"' module • Silence horn on horn/strobe over a single pair of wires using Sync•Circuit module • Sound output varies with tone and output options selected; sound levels based upon anechoic room measurements. Input terminals: Size of strobe and horn/strobe with universal plate: Size of strobe and horn/strobe with small footprint plate: Size of horn with universal mounting plate: 5" x 55/8" x 15/16" Size of horn without mounting plate: Weight, horn only Weight, strobe and horn/strobe: 8.8 oz. © System Sensor 12/96 12 to 18 AWG 5" x 55/8" x 215/16" 33/8" x 55/8" x 25/16" 215/16" X 55/16" X 15/16" 7.2 oz. Mounting: Operating temperature: Voltages: Operating 4"x4"x Ph" or 2" x 4" x 17/8" standard boxes 32° to 120° F (0° to 49° C) 12 or 24 VDC and FWR unfiltered voltage range**: 12 V, 10.5 - 17 V 24 V, 20 - 30 V * * These products should be operated within their rated voltage range; UL does, however, test functional integrity to -20% and + 10% of manufacturer's stated ranges. This document is not intended to be used for installation purposes. A05-936-01 SpectrAlert Ordering Information Horn / Strobes Strobes Horns Sync•Circuit Module Small Footprint Mounting Plate for Single Gang Only S -MP Red P1215 P121575 P2415 --).P241575 P2475 P24110 P2415A P241575A P2475A P24110A P241575F (FUEGO) S1215 S121575 S2415 '.S241575 S2475 S24110 S2415A S241575A S2475A S24110A S241575F (FUEGO) H12/24 H12/24A MDL MDLA Surface Mount Back Box Skirt BBS White , Voltage Candela P1215W .12 15 P121575W 12 15/75 P2415W 24 15 P241575W 24 15/75 P2475W 24 75 P24110W 24 110 P2415 WA 24 15 P241575WA 24 15/75 P2475WA 24 75 P24110WA 24 110 24 15/75 S1215W 12 15 S121575W 12 15/75 S2415W 24 15 5241575W 24 15/75 S2475W 24 75 S24110W 24 110 S2415WA 24 15 S241575WA 24 15/75 S2475WA 24 75 S24110WA 24 110 24 15/75 H12/24W 12/24 NA H12/24WA 12/24 NA MDLW 12/24 NA MDLWA 12/24 NA S-MPW BBSW NA NA Universal Mounting Plate (replacement) D -MP D-MPW NA NA NA NA Avg. mA* @ Nom. VDC 124 152 78 91 148 165 78 91 148 165 91 114 142 53 66 123 140 53 66 123 140 66 Avg. mA* @ Nom. FWR 167 181 98 111 167 209 98 111 167 207 111 157 171 80 93 149 191 80 93 149 191 93 12 / 23 12 / 21 12/23 12/21 16 24 16 24 NA NA NA NA NA NA Notes: Agency Listings: UL, ULC, FM, CSFM pending, MEA pending Canadian model numbers end in "A": Latin American model numbers end in "F". All SpectrAlert products are designed for wall mount only. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/strobes are recommended for 20' x 20' rooms or less. * For a complete listing of SpectrAlert current requirements, please refer to the SpectrAlert Current Draw Table or Installation Manual. Horn and horn/ strobe current draws assume horn is set at temp 3, electromechanical tone and high audibility. System Sensor Worldwide Distribution In Canada: System Sensor Canada 6581 Kitimat Road, Unit #7 Mississauga, Ontario Canada L5N 3T5 Telephone: 905-812-0767 Fax: 905-812-0771 Page 6 In the United Kingdom: System Sensor Europe, Ltd. Horsham Gates III, North St. Horsham, West Sussex RH13 5PJ, United Kingdom Telephone: 44-1403-276500 Fax: 44-1403-276501 In India: System Sensor India A-204 Maheshwari Nagar Orkay Mills Lane Andheri East, Mumbai 400093 Telefax: 91-022-8202564 In the Far East: System Sensor Pittway Far East, Ltd. Rm 903, Tower A, New Mandarin Plaza, 14 Science Museum Road TST East, Kowloon, Hong Kong Telephone: 852-2191-9003 Fax: 852-2736-6580 This document is not intended to be used for installation purposes. A05-936-01 Fire Alarm Sounders & Sounder/Strobes Model 460 DESCRIPTION Federal Signal Model 460 Sounders produc a distinctive, high dB tone using an electronic piezo. The sounder (mini horn) features a textured, impact and flame resistant hous- ing and is available in a red or white finish. The sounders operate on 12 or 24VDC (strobe models 24VDC only) and are polarized for connection to supervised alarm circuits. Federal's Visalert® V1971 strobe light is available as an option when visual signaling is required. APPLICATION Federal Model 460 Sounders can be used as remote stand-alone units or as part of a supervised signaling system. Due to their compact size and attractive appear- ance they are ideally suited for single room applications where high sound output and low current draw are a consideration. Optional strobe lights are available when visual signaling is required. Single gang plate models mount to a single gang electrical box or may be mounted to a 4" square electrical box with a single gang raised plaster extension ring (not included). Double gang plate models can be mounted to a single gang, double gang, oro" square electrical box. The compact design and wide range of mounting configurations permit the sounders to fit many applications. Model 460 Sounders carry the following listings/approvals: Agency Underwriter's Laboratories California State Fire Marshal New York City MEA Factory Mutual STANDARD FEATURES Reference Number E4813 7135-0811:109 Pending Pending • 12 or 24VDC operation. • Attractive, high impact, flame resistant plastic housing. • Low current draw. • UL sound pressure level 82 dB(A) © 10 feet (see chart). • Polarized for supervision. • Screw terminals for field connections. • Available in red or white. • Loud, distinctive tone. OPTIONAL FEATURES • Double gang plate model can mount to single gang, double gang, or 4" square box. • Visalert V1971 strobe lights (24VDC) available in 15, 40/75 (ADA), and 110 candela models. MODEL 460 Sounders and Sounder/Strobe SPECIFICATIONS Alarm indicating devices shall be electronic piezo sounders (mini horns). The sounders shall be housed in a textured, high impact, flame resistant plastic housing with a red or white finish. An optional strobe light shall be capable of being mounted to the front of the device. The sounders and sounder/strobes shall mount to either a single gang, double gang, or standard 4" square box. The sounders shall operate from 9-33.5VDC (strobe models 24VDC only) and be polarized for connection to supervised alarm circuits. The sounder shall have screw terminals for field wiring connections using #12 to #18AWG wire. The sounders shall produce a maximum UL Sound Pressure Level at 10 feet of (82dB(A) 24VDC; 79dB(A) 12VDC). The sounders shall be UL Listedforfire alarm signaling use. Sounders (mini horns) shall be Federal Signal Model 460. (OPTIONAL) The strobe lights shall be mounted to the front surface of the sounders. The strobe lights shall use a xenon flashtube with solid state circuitry. The strobe lights shall comply with UL 1971 Standard for Signaling Devices for the Hearing Impaired. The strobe lights shall be UL Rated for a light intensity ouuut of 15, 40/75" and 110 candela with a flash rate of 1/3Hz (20fpm) or 1 Hz (60fpm). The strobe lights shall have red FIRE lettering. The strobe lights operate simultaneously with the sounders. Sounder/strobes shall be Federal Signal Model 460 with Model V1971 strobe lights. 40/75 strobe avalable in 1 Hz flash rate only and exceeds 75 candela for ADA applications. FEDERAL SIGNAL CORPORATION Commercial Products Group • FireLarmTM Systems FL -460 Model 460 Sounder Specifications ORDERINGJNFORMATION Part Number Description Part Numbdr Description UL dB(A) Sound Pressure Level Sounders - Single & Double Gang UL 1971 Sounder/Strobes 460 024R Sounder, Single Gang Plate,12/24VDC, Red 460L024DGR Sounder/Strobe, 24VDC, 15 Cd, 1/3Hz, Red 460 024W Sounder, Single Gang Plate, 12/24VDC, White 460L024DGW Sounder/Strobe, 24VDC, 15 Cd, 1/3Hz, White 460 024DGR Sounder, Double Gang Plate,12/24VDC, Red 460CO24DGR Sounder/Strobe, 24VDC, 15 Cd, 1Hz, Red 460 024DGW Sounder, Double Gang Plate, 12/24VDC, White 460CO24DGW Sounder/Strobe, 24VDC, 15 Cd, 1Hz, White 460A024DGR Sounder/Strobe, 24VDC, 40/75 Cd, 1Hz, Red 460A024DGW Sounder/Strobe, 24VDC, 40/75 Cd, 1Hz, White 460H024DGR Sounder/Strobe, 24VDC, 110 Cd, 1/3Hz, Red 460H024DGW Sounder/Strobe, 24VDC, 110 Cd, 1/3Hz, White 460S024DGR Sounder/Strobe, 24VDC, 110 Cd, 1Hz, Red 460S024DGW Sounder/Strobe, 24VDC, 110 Cd, 1Hz, White Model 460 Sounder Specifications Part Number Nominal Input Voltage Rated Voltage Range Current @ 24VDC UL dB(A) Sound Pressure Level dB(A) Sound Power Level UL 1971 Rated Candela Flash Rate 460 024 460 024 460L024DG 4600O24DG 460A024DG 460H024DG 460S024DG 12VDC 24VDC 24VDC 24VDC 24VDC 24VDC . 24VDC 9 to 33.5VDC 9 to 33.5VDC 18 to 31VDC 18 to 31 VDC 18 to 31 VDC 18 to 31VDC 20to31VDC 0.012A 0.015A 0.049A 0.088A 0.163A 0.118A 0.259A 79 82 82 82 82 82 82 99.6 104.4 104.1 104.1 104.1 104.1 104.1 n/a n/a 15 15 40/75' 110 110 n/a n/a 1/3Hz 1Hz 1Hz 1/3Hz 1Hz NOTES: 1. This model is rated at 40 candela per UL 1971 with a peak candela rating exceeding 75 candela for ADA applications. SINGLE GANG BACK BOX (not provided) MOUNTING OPTIONS 4" x 4" ELECTRICAL BOX WITH SINGLE GANG PLASTER EXTENSION RING (not provided) SINGLE GANG BACK BOX (not provided) 4" x 4" ELECTRICAL BOX OR DOUBLE GANG BOX (not provided) FireLarmTM Systems FL -460 (02/96) - r.pac.4(09/94) FEDERAL SIGNAL CORPORATION TM FIRELARM ®VISALERT ® FEDERAL SIGNAL CORPORATION, 1996 APPEARANCE DETAILS ARE SUBJECT TO IMPROVEMENT WITHOUT NOTICE or FEDERAL SIGNAL CORPORATION Commercial Products Group 1130 Milepost Drive Columbus, Ohio 43228 614/870-6677 • FAX 614/870-6975 ELECTRICAL / FIRE ALARM PERMIT COVER SHEET DATE: 5-16-97 AHJ: TUKWILA FIRE DEPARTMENT JOB NAME: JOB ADDRESS: HOMESTEAD VILLAGE 15635 WEST VALLEY HWY TUKWILA WA PROPERTY OWNER: HOMESTEAD VILLAGE ELECTRICAL CONTRACTOR: SYSTEMS TECHNOLOGY PO BOX 3282 KIRKLAND WA 98033 CONT. LIC. #SYSTET*044RT CONTACT: JEANNE WIGGINS (425)226-8921 DESCRIPTION OF WORK: DESCRIP. OF OCCUPANCY: WIRING METHOD: SPRINKLER SYSTEM: 14 INSTALL FIRE ALARM SYSTEM [ ] INSTALL FIRE DETECTION SYSTEM [ ] EXPAND EXISTING FIRE ALARM SYSTEM [ ] INSTALL MONITORING [ ] OTHER [ ] COMMERCIAL [)C] MULTI FAMILY -R1 HOTEL/MOTEL [ ] SINGLE FAMILY [X] LOW VOLTAGE OPEN CABLE [ ] OTHER KI YES []NO NUMBER OF CONTROL UNITS: 1 NUMBER OF ZONES: ADDRESSABLE SYSTEM NUMBER OF DEVICES: 286 t i CLAY 2 1 1997 FIRE ALARM SYSTEM SCHEDULE OF EQUIPMENT PROJECT: HOMESTEAD VILLAGE - TUKWILA CONTRACTOR: SYSTEMS TECHNOLOGY Provide & Install: One (1) Fire Lite MS -9200 Addressable Fire Alarm Control Panel One (1) FCPS24F Auxiliary Power Supply One (1) UDACT-F Digital Communicator One (1) LCD40 Alpha/Numeric Annunciator - in room smoke detector annunciation Ninety -Six (96) SD300 Addressable Photoelectric Smoke Detectors - in room detectors Ten (10) BK -2400 Photoelectric Smoke Detectors Five (5) Edwards 281B Rate of Rise/Fixed Temp Heat Detectors Twenty (20) Addressable Monitor Modules Seventeen (17) BG1OLX Addressable Manual Pull Stations Fifty -Two (52) System Sensor BK -P241575 Horn/Strobes Twelve (12) System Sensor BK -S241575 Strobes Eighty -Nine (89) Federal Signal 460 024 Mini Horns Provide Connection To: Waterflow Switches Tamper Switches Door Holders Elevator Re -call ,,:7)• It() i gnu 1t):.Ju r L. -4 4 11 0i -ll L11� .2. Tfie Main Power Supply M S" 9 2 0 0 The MS -9200 provides regulated power for operating the fire alarm control panel, operating external devices, and operating the standby battery. The power for operating external devices is limited. Use Table A -2A (standby or non -alarm) and Table A -2B (alarm) to determine i dxtemal loading is within the capabilities of the MS -9200 power supply_ Concerning smoke detectors: Refer to the manufacturer's data sheet packaged with each smoke detector to find the standby and alarm current draws to use in the tables of this Appendix. Be sure to power detectors from TB4, Terminals 5 and 6. Table A -2A: Regulated Load in Standby @2° "DC External Devices connected to TB4 only Notes: 1) 2) 3) 4) 5) 6) Dallo 1yDe f Q DITS ea Steraby Total Camera CannR IAmif1 WWI) Malin Onsell 6oera 1 X 0.08 = 0_1:e R7141.9F [ [ ac Tex X MOOD . 21340.16E 1 [ one max x 0.00005 = • r- AF1I-,0ATZ A 32ax [ )0.,e nuc X 0.04 . ^� A9*16ATF ADM -2126F 1 1 X 0.002 = `—. AR I-16ATF AM -320F 1 1 X 0.04 = AFA4-I9AF 1 1 X o.026 . . -,�- UDACT-F J+ 1 one mac X 0.00 - . D if f �• 1 1 x CUMJ LD 32F 1 1 X 0.002 tLa<o 1 X 0.05' . O 51i. 4Wke Smoke Damao(1 1 X 1 1 - Powe S$p:wee an Relay1 1 X 0.024 _ _• CR300 [ 1 x 0.00015 = 93300 S T 9 6 1 1 x x 0.00015 0.0002 = = . o l 4 4 114300 5 x 0.0302 = . 0 0 ' 11001 1 1 X 0.0002 _ 14302 15 x 0.037 - . 1 0 S ect,auc '7X 0.00a2 =. o o y caw x 0.0002 .O D O S 1300 1 1 x 0.0004 = 3um Column tar Bomdby Lod ., 29810 TB4. Terminals 1 and 2: Non -Regulated, 24 VDC, 2.5 amps. TB4, Terminals 3 and 4: Regulated, Filtered 24 VDC +/- 5% 120Hz ripple 010 mVgMs 7194, Terminals 5 and 6: Regulated, Filtered 24 VDC +/- 5% 120Hz ripple l 10 mVRMs T84, Terminals 3 and 4; are nonresettable auxiliary power, 300 mA. T84. Terminals 5 and 6 are resettable (smoke detector power), 300 mA. Refer to Current Limitations on next page. 72 _ Document r 15004 Flew. N 323196 PM 15644 H 141 01) :IJ 1J0 J 1 lnl.i 1V..JV r_i_i 40-41110 r 11(tL11t, LO 003 Table A -2B: Regulated Load in Alarm °241°C External Devices connected to 7732 and T84 Device Type *of oetilctn Main Circuit Board , 1 RTM-8F ZDM-16F AFM-16ATX AFM-32AX AEM-16ATF AEM-32AF AFM-16ATF AFM-32AF AFM-16AF UDACT-F LDM-32F LDM-E32F LCD -40 , 4 -Wire Smoke Detector Paver Supenlslon Relay Addressable Devloes Notification Appliances Current (AmP-) X 0.168 1 X 4 0.146 1 X 0.085 = 8 (] X 0.056 [ ] X 0.018 6 (j X 0.056 - 5 [ ] X 0.065 X 0.075 7 ( ] X 0.056 [ ] X 0.018 = X 0.054 [] X [] X Marr_Draw AO X 0.2 Devices 23 X •091 7 X • 066 z3 ,c •0l5 Surra Column for Afarm Load - 6 Total Current (Amps) 0.168 .075 •054- 02 2.09 .46 • 3145 3.397 Refer to next page for battery calculations using Total Standby and Total Alarm Loads. Notes: 1) Current limitations of terminals: • TB4, Terminals 1 and 2 = 2.50 Amps. • TB4, Terminals 3 and 4 = 0.300Amp. • TB4, Terminals 5 and 6 = 0.300 Amp. • 7731 and TB2, Any one circuit = 2.50 Amps. 2) Total current draw of terminals listed above cannot exceed: 3.6 Amps - With Standard Transformer (XRM-1) installed alone. - 6.0 Amps - With both Standard Transformer (XRM-1) and optional Transformer (XRM-24) installed. • Total current from T84, Terminals 3 and 4, 5 and 6 not to exceed 0.600 amperes. • Total System power Is 6.6 amps max. 3) M302 Monitor Module current limit at 90 mA in alarm_ 4) All RTM-BF Relays activated. 5) All 16 ZDM-16F LEDs on. 6) All Annunciator LEDs on. 7) UDACT-F actively making phone call to Central Station. If the normally open contact is used, current consumption increases to 100mA. 8) LDM-32F with LEDs on. 9) This column must not exceed 6.6 amps. O.� Document • 15668 Rev. F 9t1uP5 PIN 15666:F 73 *,o• • inu tu.u r40-1Illtl t Kt. Li t. BATTERY CALCULATIONS Use the Total Standby and Alarm Load Currents calcbiated in Tables A -2A and A -2B for the following battery calculation. Standby Load Required Standby Time in Current (Amps) X Hours (24 or 60 Hours) .a98cg [29] = 7. / Co 67 i. Alarm Load Required Alarm Time in Hours Current (Amps) X (i.e_ 5 min_ = 0.084) 3,391 1.o$4) _ . 2853 Add Standby and Alarm Load for Required Ampere Hour Battery = 7, 'r5) 7 Multiply by the Derating Factor of 1.2 = S , 9 4 7, Total Ampere Hours (AH) Required = ) 2 X a_ NOTE: - 74 -12ftrt 1) 7 AH battery can be located in the MS -9200 Backbox. 2) 12 AH and 17 AH batteries require the Fire•Llte BB -17F Battery box. 3) 20 AH to 55 AH batteries require the Fire•Lite R45-24 Charger for housing and charging batteries. hDoauoent • 'Mee Rev. P WIMIS PM 156®;6 I41 004 1'11\L'Ll 1L ai.Anmo CHAPTER FIVE VUl Battery Calculations -Aux ?oR Soppy Page 20 5.0 External Device Power The FCPS-24F provides filtered 24VDC power that may be used for operating Notification Appliance Circuits or other external devices. The power for operating external devices is limited. Use Table 5-1 (standby or nonalarm) and Table 5-2 (alarm) to determine if external loading is within the capabilities of the power supply. Refer to the device manufacturer's data sheets packaged with each device to find the standby and alarm current draws to use in the Tables. 5.1 Device Standby Current Draw The total standby current draw of all devices on each active output, including end of line relays when used for supervision. Note: ELRs should not be used on these circuits_ Device Type # of Devices Current (Amps) Total Current (Amps) Main PC Board without AC Fail Report Delay Enabled (1 maximum) X 0.032 OR = Main PC Board with AC Fail Report Delay Enabled (1 maximum) X 0.048 D.04-5 EOL Relays [ ] X = --- Smoke Detectors [ ] X = — Smoke Detectors [ ] X = —_ EOL Resistors [ ] X = --- Annunciators [ ] X = Aux. Devices [ ] X = Aux. Devices [ ] X = Aux. Devices [ ] X = --- Sum Column for Standby Load = a 0/18Amps 0 Table 5-1: Load in Standby 6241DQ Document 1 5007P Rev. A 12/W94 ��:�• i�- �i tGL 10:41 rAA :U4Vi411.1tS tlkthLllt. iL.{K.11S 00 taj00Y Standby Current Calculation Subtract total standby load calculated above from 0.166'AH for 24 hours or 0.66 AN for 60 hours. This figure cannot be less than zero. If the amount is fess than zero, the required standbptime will not be achieved. MaximumCurrent Draw: Five minutes under full Toad (6.0A current draw) requires 3.0 AH of a 7.0 AH capacity battery. The remaining 4.0 AH capacity must support the FCPS-24Fduring its required standby time_ Beca use of t his, the standby current draw cannot exceed the figures listed below: 1) For 24 hour standby time, the standby current draw cannot exceed 0.166 amps at 24 VDC (24 hours x 0.166A) = 3.984 AH 2) For 60 hour standby time, the standby current draw cannot exceed 0.066 amps at 24 VDC (60 hours x 0.066A) = 3.96 AH Device Type # of Devices Current (Amps) Total Current (Amps) Main PC Board without AC Fail Report Delay Enabled (1 maximum) X 0.032 OR = Main PC Board with AC Fail (1 maximum) X 0.048. Report Delay Enabled' 0 4 8 EOL Relays [ ] X = _• Smoke Detectors [ ] X _ Smoke Detectors EOL Resistors [ ] [ ] X X = ._.., _ Annunciators [ ] X = _.., Aux. Devices [ ] X = _. Aux. Devices [ ] X Aux. Devices 1 1 X Notification Appliances [:(11 X , Oq 1 = 2 X 39 Notification Appliances [ 6] X • 0 6 (0 = • 33 Notification Appliances [toe] X . 015 = .99 Sum Column for Alarm Load =4. on 7Amps Table 5-2: Load in Alarm °24V13c t1.7; 1 ItLL I 110 r ilttLl It iL.ltU' Secondary Power Source Calculations Use the Total Standby and Alarm Load Currents calculated in Tables 5-1 and 5-2 for the following battery cafculation_ Standby Load Current (Amps) ,048 X Required Standby Time in Hours (24 or 60 Hours) [24-) = 1.152 Alarm Load Current (Amps) 4,007 X Required Alarm Time in Hours (Le. 5 min. = 0.084 hours) [,0841 _ • 3 3 7 Add Standby and Alarm Load for Required Ampere Hour Battery = 1 489 Multiply by the Derating Factor of 1.2 = 1. 78 7 Total Ampere Hours (AH) Required = 2 - 7A H b' rr: 's MS -9200 Addressable Fire Alarm Control Panel GENERAL The MS -9200 is a compact, cost effective, address- able fire alarm control panel with a capacity of 198 Fire•Lite Series 300 devices. A single SLC loop supports up to 99 smoke or heat detectors and 99 control or monitor modules. The panel uses the lat- est in surface -mount technology, and is designed for ease of installation and programming. It features the latest in fire protection technology, including: main- tenance alert and automatic detector test. FEATURES • 198 addressable device capacity (99 detectors and 99 monitor or control modules), Style 4, 6, or 7. • 2 programmable internal Notification Appliance (bell, signal) Circuits, Style Y or Z (Class B or A). • Alarm, trouble and supervisory relays, standard. • Maintenance alert warns when smoke detector dust accumulation is excessive. • Optional Digital Alarm Communicator reports 56 zones or 198 points to Central Station. • Remote serial annunciators operate over high speed EIA -485 port. • Optional printer interface. • 3.0 Amp Notification Appliance (bell,signal) power, expandable to 6.0 Amperes. • 40 character LCD display with back -lighting. • Custom English labels per point may be manually en- tered or selected from an internal library file. • Real time clock/calendar. • History file with 500 event capacity. • Waterflow or supervisory selection per monitor point. • System alarm verification, smoke only. • Walk Test reports 2 devices set to same address. • Presignal delay option per NFPA 72. • Silence Inhibit and Auto Silence timer options. • March Time/Temporal/California code for non-silencable bell circuits. • Field -programmable on panel, with user -defined pass- words, plus an Autoprogram feature. • Battery charger for up to 60 hours of standby power. • Remote Acknowledge/Silence/Reset/Drill via M300 modules. • Optional monitor module supports two -wire smoke de- tectors. Califomia State Fire Marshal 7165-0075:158 OX9A3.AY S624 MEA 16-94-E (for MS -9200 & M302) + MS -9200 dressable Fie Pans! The MS -9200 15.0"Hx145"Wx3.0"D • Rapid poll algorithm for manual stations. Responds in less than 2 seconds. • Operates with untwisted, unshielded wire (up to 1,000 feet) for retrofit applications (U. S. Patent 5,210,523). • New 300 Series addressable devices feature decimal address selection. Address of each device can be easily set in the' field by use of a screwdriver. Smoke detectors also feature a plug-in wiring connector. • SLC loop maximum length 10,000 ft. AGENCY LISTINGS AND APPROVALS In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. 12 Clintonville Road Flre'LITe®ALarrns Northford, CT 06472 IncorporaTED Phone: (203) 484-7161 FAX: (203) 484-7118 ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Made in the U.S.A. DF -51276 Page 1 of 4 September 14, 1994 Page 2 of 4 Catalog sheet DF -51276 SYSTEM PERIPHERALS SLC Loop (2 wires) SD300 CP300 SD -300T MS -9200 EIA -485 (2 wires) 198 devices 56 software zones Notification (Bell, Signal) Circuits 24 VDC FIRE BG -10t -X M302 Supervised loop of 2 -wire smoke detectors M300 B Q M301 Miniature version of M300 Supervised Initiating Device Circuit (contact type) C300, C304 Supervised Indicating Appliances Circuit or Form C relay 24 VDC - 1 8 Optional Form C Relays (order RTM-8F). Optional EIA -232 interface module for PC computer or diagnostic printer (PIM -24 required]. CI= -u =u =I . Mu Mi 1 =n =u =u =i 1 Mu MIS n= Fl 11= ■i= n= 1i= =u _u 1 =I l n= ii- 11 1 — 1 1= 1 I= a•n =u .0 _u =11 AFM Series Annunciators LDM Series Graphic Annunciator 56 zones/198 points ADDRESSABLE DEVICES SD300 Addressable photoelectric smoke detector. Includes mounting plate and plug-in wiring terminal block. SD300T Same as SD300, plus a 135° F. thermostat heat detector. CP300 Addressable Ionization smoke detector. BG-10LX Addressable manual station based on the popular Fire•Lite BG -10 dual -action station. Made of LEXAN®. M300 Addressable monitor module for one zone of dry contact initiating devices. Mounts in standard 4 -inch box. Includes plastic cover plate and end -of -line resistor. Features polling/ alarm LED and decimal address switches. May be configured for either Style B (Class B) of Style D (Class A). M301 Miniature version of M300. Excludes LED and Style D option. Connects with wire pigtails. M302 Similar to M300, but may monitor up to 20 conventional 2 -wire detectors. Requires external 24 V power. (Consult factory for compatible smoke detectors & availability). C300 Addressable control module for one Style Y zone of supervised polarized Notification Appliances, or may be configured as a dry contact (Form C) relay. Mounts in standard 4 -inch box. Features polling LED and decimal address switches. Notification Appliance Circuit option requires external 24 VDC power. (Consult factory for compatible Notification Appliances). I300 This module isolates the SLC loop from short circuit conditions. AFM ANNUNCIATORS AFM-16ATX/AEM-16ATF Serial remote annunciator modules may be located up to 6,000 feet from the panel. The AFM-16ATX displays alarm and trouble for 16 points or zones. Expandable to 64 points using up to three AEM-16ATF's. May also perform remote silence and reset. The first four switches from one annunciator may be used to remotely acknowledge, silence, reset, or to perform a drill. AFM-32AX/AEM-32AF Alarm -only indication by zone, with 32 alarm LEDs per module. AFM-32AX may support one AEM-32AF for a maximum of 64 zones. AFM-16AF Alarm indication only. 16 alarm LEDs, common trouble LED. Mounts to standard 4 gang box. ABS -1F & ABS -2F Surface mount annunciator boxes accept one or two annunciator modules. ABF -1F, ABF -2F, & ABF -4F Flush mount boxes accept 1, 2, or 4 modules. AKS -1F Annunciator key switch kit for use with AFM-16AT when used with ABF boxes. LDM Annunciators LDM-32F and LDM-E32F may be used for custom graphic annunciators which may be located up to 6000 feet from the panel. Catalog sheet DF -51276 FIELD PROGRAMMING FEATURES Off -Line Programming Create entire program in your office using a DOS based PC computer (order programming kit PK - 9200 separately). Upload/Download system programming to the MS -9200 in less than one minute. Auto -Programming Command the MS -9200 to program itself (takes less than 30 seconds). In the Auto -Program mode, the MS - 9200 scans for all possible devices at all addresses, stores the device types, and addresses found, and then loads default values for all options (General Alarm). It also checks for two or more devices set to the same address. On -Line Edit While still providing fire protection, the MS -9200 may be programmed from the front panel. Simple menu trees displayed on the LCD allow the trained user to perform all functions without referring back to the programming manual. English Label Library Quickly select labels from a standard library "FLR 3 HALLWAY:, or enter them in letter -by -letter. Use recall function to repeat previously used label. Program Check Automatically catch common errors, such as relays not linked to any zone or point. MAINTENANCE ALERT The MS -9200 continually monitors each smoke detector and responds to a reading of 80% of the detectors alarm threshold. If the detector continually reports an 80% threshold reading (8/10 of what is required to be an alarm) for 24 hours, a trouble condition is created. This reduces the risk of false alarms due to dust and dirt by creating a trouble condition and not an alarm. AUTOMATIC TEST OPERATION The MS -9200 performs an automatic test of each detector every 2 hours. Failure to meet the test limits causes an AUTO TEST FAIL trouble type. System Reset clears this trouble. THE MS -9200 COMPLIES WITH THE FOLLOWING NFPA STANDARDS: NFPA 71 Central Station Signaling Systems (Automatic, Manual, and Waterflow) Protected Premises Unit (Requires UDACT-F). NFPA 72 Local (Automatic, Manual, Waterflow and Sprinkler Supervisory) Protective Signaling Systems. NFPA 72 Auxiliary (Automatic, Manual, and Waterflow) Protec- tive Signaling Systems (Requires RTM-8F). NFPA 72 Remote Station (Automatic, Manual, and Waterflow) Protective Signaling Systems. (Requires RTM-8F or UDACT-F). NFPA 72 Proprietary (Automatic, Manual, and Waterflow) Pro- tective Signaling Systems (Protected Premises Unit). Page 3 of 4 ■■■■••■■■•••■••■ 1 2 3 4 5 6 7 8 910 11 12 13 14 15 16 ■ ■ ■ ■ ■ AC FIRE SUPER- ALARM SYSTEM POWER ALARM VISORY SILENCE TROUBLE ACKNOWLEDGE ALARM ALARM SYSTEM STEP SILENCE ACTIVATE RESET 1 OHI 4 P705 ABC DEF 3 JKL 5 TUV 8 MNO 6 W9 %Y OZ 0 DET RECALL MOD ENTER v PP - Keypad and 40 Character LCD Display (with back lighting feature) SPECIFICATIONS • Primary input power: 120 VAC, 50/60 Hz, 2.3 Amps. • Total output 24 V power: 3.6 A (expandable to 6.6). • Standard Notification Circuits: 2 (Style Y or Z). Expansion Notification Circuits: up to 99 (using C300 module). • Notification Appliance Power : 3.0 A (expandable to 6.0 A with XRM-24). • Four -wire detector power : 300 mA*. • Non-resettable regulated power : 300 mA*. • Non-regulated power : 2.5 Amps Maximum*. NOTE: Subtract from total 24V power. • Battery charger range: 7 AH - 17 AH (BB -17F battery cab- inet for 12 - 17 AH batteries). • Remote charger (panel charger disabled): 25-55 AH (use R45-24). • Charge float rate: 27.6 V. • Charger current limited to 0.8 A.. • Control panel Alarm, Trouble, Supervisory Relay contact rating: 2.0 A @ 30 VDC. SYSTEM CAPACITY: • Total programmable input/output points 198 • Addressable Detectors 99 • Addressable monitor or control modules 99 • Programmable NAC (bell) circuits in panel 2* • Programmable software zones 56 • AFM annunciators per system 4 NOTE: * NAC circuits are expandable using C300 control module. CONTROLS AND INDICATORS LED INDICATORS 1. AC POWER (green). 2. FIRE ALARM (red). 3. SUPERVISORY (yellow). 4. ALARM SILENCE (yellow). 5. SYSTEM TROUBLE (yellow). MEMBRANE SWITCH CONTROLS 1. 2. 3. 4. 5-16. 17 — 20. 21. ACKNOWLEDGE/STEP ALARM SILENCE DRILL SYSTEM RESET (lamp test) 12 key pad with full alphabet 4 cursor keys ENTER LCD DISPLAY 40 characters (2 X 20) with long -life LCD display, back -lit. COMPATIBLE ADDRESSABLE DEVICES MODEL DESCRIPTION CP300 Ionization Smoke Detector. SD300 Photoelectric Smoke Detector. SD300T Photoelectric with 135° F. thermal element. M300 Monitor Module. M301 Miniature Monitor Module. M302 2 -Wire Detector Monitor Module. C300 Control Module, Style Y. BG-10LX Manual Fire Alarm Station, Addressable. 1300 Isolator Module C304 Control Module, Style Y and Z. EIA -232 PORT MODEL DESCRIPTION PIM -24 Printer/PC Interface Module. COMPATIBLE DEVICES, EIA -485 PORT MODEL AFM-16ATX AEM-16ATF AFM-32AX AEM-32AF AFM-16AF LDM-Series DESCRIPTION Annunciator Fixed Module, 16 Alarm LEDs, 16 Trouble LEDs, and 16 Switches,. Accepts up to 3 AEM-16ATF expanders. Annunciator Expander Module, 16 Alarm LEDs, 16 Trouble LEDs. Annunciator Fixed Module, 32 Alarm LEDs, Common Trouble LED. Annunciator Expander Module, 32 Alarm LEDs. Annunciator Fixed Module, 16 Alarm LEDs, Common Trouble LEDs. Mounts to four gang box. Custom graphic annunciator interface modules. PRODUCT LINE INFORMATION MODEL DESCRIPTION MS -9200 Addressable Fire Panel. Includes display, single printed circuit board, and cabinet. ZDM-16F 16 Zone LED Annunciator Option Module. RTM-8F Plug-in Relay Transmitter Option Module. Provides 8 Form -C relays, plus municipal box & remote station connections. DP -9200 Full length internal dead front panel (required for Canadian applications). UDACTF Digital Alarm Communicator/Transmitter. (Central Station Interface) XRM-24 120 VAC, 100 VA Transformer. Expands systems power supply. Expands Notification Appliance power from 3.0 amps to 6.0 amps. PIM -24 Printer and PC Interface Module required for PC programming or to connect a 40 or 80 column printer (See owners manual for additional information). PK -9200 Programming Kit for DOS based PC computer. LDM-32F Graphic Annunciator Interface Module, Master. LDM-E32F Graphic Annunciator Interface Expander Module. PS -1270 Battery, 12 volt, 7.0 AH, (two required). PS -12120 Battery, 12 volt, 12.0 AH, (two required). PS -12170 Battery, 12 volt, 17.0 AH, (two required). BB -17F Battery box, required to mount PS -12120 or PS -12170. R45-24 Remote charger and battery cabinet. Allows charging 25 to 55 AH batteries. PS -12250 Battery, 12 volt, 25 AH, (two required). PS -12550 Battery, 12 volt, 55 AH, (two required). FCPS-24F Remote Power Supply expands NAC's outputs and total system power. We try to keep our product information up-to-date and accurate. We cannot cover specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fir2.UT@° DF -51276 Fitau-reALarrns IncorPoraTeD • GENERAL The FCPS-24F(E) is a compact, cost-effective, 6 -amp re- mote power supply with battery charger. The FCPS-24F(E) may be connected to any 12- or 24 -volt Fire Alarm Control Panel (FACP) or may stand alone. Primary applications in- clude Notification Appliance (bell) Circuit expansion (to sup- port ADA requirements) or auxiliary power to support 24 - volt system accessories. The FCPS provides regulated and filtered 24 VDC power to four Notification Appliance Circuits (NACs) (two Class A [Style Z] and two Class B [Style Y] or four Class B only). Alternately, the four outputs may be con- figured as any combination of resettable/non-resettable power outputs (optimal for powering 4 -wire smoke detectors). The FCPS-24F(E) also contains a battery charger capable of charging up to 7.0 Amp Hour batteries. FEATURES • Requires input trigger voltage of 9.0 - 32 VDC. • Contains two, fully -isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [stand-alone mode]). • Two Class A (Style Z) or Class B (Style Y) Notification Appliance Circuits (circuits 1 & 3). • Two additional NACs that may be individually config- ured for Class B (Style Y) operation only (circuits 2 & 4). • 6 Amp full load output (3 amps max./ckt.) in NAC expander mode (UL 864). • 4 amp continuous output in stand-alone mode (UL1481). In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP re- quired) or non-resettable. Fully regulated and filtered power output (optimal for powering 4 -wire smoke detectors, annunciators and other system peripherals requiring regulated / filtered power). • Fuseless, power -limited technology meets NEW UL Power -Limiting requirements, effective May 1, 1995. • Normally closed trouble contact. • Fully supervised power supply, battery and Notification Appliance Circuits. • Selectable earth fault detection. ▪ • AC trouble report selectable for immediate, 8 or 16 o hour delay. D-100 FCPS-24F(E) ,24 Volt, 6 Amp Remote Power Supply Catalog Section: Power Supplies/Accessories February 27, 1996 S2424 (FCPS-24F) (FCPS-24F FCPS-24F(E)) California MEA State Fire Marshal 387-94-E 7315-0075:176 (FCPS-24F) (FCPS-24F) • Self-contained in compact, lockable cabinet (15'H x 14.5"W x 2.75"D). • Includes integral battery charger capable of charging up to 7.0 AH batteries. • Fixed, clamp -type terminal blocks accomodate up to 12 AWG wire. STANDARDS and CODES The FCPS-24F complies with the following standards: NFPA 72-1993 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems (stand-alone mode). SPECIFICATIONS Please see reverse side for specifications. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite. Phone: (203) 484-7161 FAX: (203) 484-7118 @FireurEALarrns 12 Clintonville Road, Northford, Connecticut 06472 ncorroraTeo ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Made in the U.S.A. Page 1 of 3 SPECIFICATIONS Primary (AC) Power • FCPS-24F: 120 VAC 50/60 Hz, 2.0 A maximum. • FCPS-24FE: 220/240 VAC 50/60 Hz, 1.0 A maximum. • Wire size: minimum #14 AWG with 600V insulation. Control Input Circuit • Trigger Input Voltage - 9.0 to 32 VDC. Trouble Contact Rating • 5 amps at 24VDC. Auxiliary Power Output • Specific Application Power - 45 mA Short Circuit. Output Circuits • +24 VDC (19.1 - 26.4) filtered, regulated. • 3.0 amps maximum for any one circuit. • 4.0 amps maximum total continuous current for all outputs (Stand-alone'mode). • 6.0 amps maximum total short-term current for all outputs (NAC Expander mode). Secondary Power (Battery) Charging Circuit • Supports lead acid batteries only. • Float Charge Voltage: 27.6V. • Maximum Charge Current: 250 mA. • Maximum Battery Capacity: 7.0 AH. TERMINAL DESIGNATIONS To Transformer #2 To Transformer #1 __ z o o w < < TB1 P1 2 _•:•_ Tao } N 5- y N N} Y • >. Z` T Z. T Z` T Z` . Z. J. •- N N el PI 40 01 .4 K 7>> 7 7 J= 7 7 0 n a a a a 0. 0. a a s a 0. > > > > > > > > > > > 0 0 0 0 0 0 0 0 0 0 0 0 1 2 3 4 5 8 7 8 9 10 11 12 E®EEEEEUIDIEEE FCPS-24F(E) 0 0 n [F51 )JP1 13� -C' BBattery fuse 10A 3AG slow blow TB2 R27 0) m o0] O 0 0) a N N CO = 1- ©000©00 C = :o 0) 2 W 2 N 01 0) O 0 an U LL o 0 0 0 0 R175 R76 R176 MD• R63 R134 1 D31 JP2 C 0 7 9 Tai Notes: 1) Cut JP1 to use a UL listed external battery charger. 2) Cut R134 to delay AC loss reporting for 8 hours (24-hour standby), or cut R134 and R76 to delay AC loss reporting 16 hours (60 -hour standby). 3) Cut R175 to make output #2 non-resettable in stand-alone mode. 4) Cut R176 to make output #4 non-resettable in stand-alone mode. In + In (Control Input #1 from FACP) Out +/Trouble Contact Out - ' Trouble Contact In In +(Control Input #2 from FACP) Auxiliary Output (+24 VDC, 10 mA max) Common ORDERING INFORMATION FCPS-24F Remote charger power supply. Includes main printed circuit board, transformers, surface mount backbox, and installation instructions (120 VAC). A77 -716B 12/24 VDC end -of -line relay for monitoring 4 -wire smoke detector power. Page 2 of 3 FCPS-24F(E) Remote charger power supply. Includes main printed circuit board, transformers, surface mount backbox, and installation instructions (220/240 VAC). PS -1270 Battery, 12 volt, 7.0 AH (two required). i U DACT-F Universal Digital Alarm Communicator Transmitter GENERAL The FireLite Universal Digital Alarm Communicator Trans- mitter (UDACT-F) may be used on the FireLite MS -9200 and Sensiscan 2000 control panels. The UDACT-F transmits sys- tem status to UL Listed Central Station Receivers via the public switched telephone network. The UDACT-F is compact in size and may be mounted inside the host control panel or may mount externally in a separate cabinet. EIA -485 annunciator communications bus and regu- lated 24 volt connections are required. The UDACT-F trans- mits 198 points or 56 zones when connected to the MS -9200 and 56 zones when connected to the Sensiscan 2000. FEATURES * Dual phone lines * Dual telephone line voltage detect * Surface Mount Technology * Compact in size: 6.75" x 4.25" * Built-in Programmer * Built-in 4 character red 7 -segment LED display * Manual Test Report Function * Manual Transmission Clear Function * Mounts either inside control panel or in separate enclosure * Communicates vital system status including: - Independent zone/point alarm (See Type Mode) - Independent zone/point trouble - Independent zone/point supervisory - AC (mains) Power Loss (programmable) - Low Battery and Earth Fault - System Off Normal - 12 or 24 hour Test Signal - Abnormal Test Signal per new UL requirements - EIA -485 Communication Bus Failure * Annunciation of UDACT-F Troubles including: Loss of phone lines, communication failure with either Central Station, total communications failure. * Troubleshoot Mode converts keypad to DTMF touchpad * Individual LEDs for: Power, EIA -485 loss, Manual Test, Kissoff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications * Open Collector relay driver for Total Communications Failure or UDAC-T trouble. * Real Time Clock * Extensive Transient Protection * Simple EIA -485 interface to host panel. 12 Clintonville Road Fire LITe ALarrnS Northfoid, CT 06472 mcorporareo Phone: (203) 484-7161 FAX: (203) 484-7118 1111MMI111.1111111111i S624 Contactor oa Dads d baud FCC INDUSTRY CANADA IWGUSA-20723-AL-E 2132 6030 A Primary StowWary Y F?i ModWar Cable 4 -PM MCOL4 F'1 p PRIMARY a h,E GPM 1411. --4 o. .110 P1 1111111 11111111 PHI ra 0 ONOSITAFIT n o Err. SECONDARY p UNNEIROM. 1610171 MAYO. comurimpoovnumernoi DRONER ❑COro. FAR - 0 BA -185 ❑EIb4a5 ❑lass OFF Ter MODE CD000CI 0.0000 DEfl00 0E1000 EYEKT 1111111 CONPIECIDR CD UDACT-F 0 0 10 ABS-8RF ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Al Made in the U.S.A. DF -51294 Page 1 of 2 August 23, 1994 INSTALLATION MS -9200: Mounts to main circuit board with four standoffs. Sensiscan 2000: Mounts to lower level of CHS -4 chassis using two standoffs and two support posts. For external mounting, use ABS-8RF or UBS -1F enclosure. Al- lows location up to 6000 feet from control panel. COMMUNICATION FORMATS * 3+1 Standard * 4+1 Standard * 4+2 Standard * Ademco Contact ID * 4+1 and 4+2 Ademco Express Note: Ademco Contact ID must be used for independent zone/point reporting. See chart for compatible receivers. ORDERING INFORMATION UDACT-F: Includes operating instructions, programming instructions and mounting hardware. MCBL-7: DACT Telephone lines. Two seven foot lines included. ABS-8RF: Metal enclosure for external mounting up to 6000 ft. from host FACP. Type Mode Feature: (Ademco Contact ID format only) Use Type Mode to identify reports to Central Station as: * Fire Alarm * Supervisory * Pullstation * Heat Detector * Waterflow * Duct Detector * Flame Sensor * Smoke Zone UBS -1 F Format # Addresses 16 & 42) UBS -1F GST -24: MR -101/C: MR -201/C: FBD-1 Metal enclosure includes viewing window and relay mounting. Mounts up to 6000 ft. from host FACP. Ground Start Module. Used in ground start telephone networks. SPDT Form -C relay. Contacts rated for 10A @ 115 VAC. Connects to open collector relay driver. DPDT Two Form -C relays. Contacts rated for 10A @ 115 VAC. Connects to open collector relay driver. Ferrite bead kit. Use for remote mounting only. ELECTRICAL SPECIFICATIONS Standby current: 40mA Current while communicating: 75mA Maximum current while communicating and with open collector output activated: 100mA Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. E Z- V W co 0 O 0 CO N ¶, mV H iti 2 E N mo E m o� o o Q N 0 (n 0 M 0 4+1 Ademco Express ✓ ✓ 1 4+2 Ademco Express ✓ ✓ ✓(8) 2 3+1/Standard/1800/2300 ✓ ✓ (2) ✓ ✓ (4) ✓ 6/(5,6) ✓ 3 Not Used 4 3+1/Standard/1900/1400 ✓ ✓ (2) ✓ (4) V ✓ 5 Not Used 6 4+1/Standard/1800/2300 ✓ ✓ (2) ✓ ✓ (4) ✓ ✓ (5) ✓ 7 Not Used 8 4+1/Standard/1900/1400 ✓ ✓ (2) V (4) ✓ ✓ 9 Not Used A 4+2/Standard/1800/2300 ✓ V (2) ✓ ✓ (4) V ✓ (5) ✓ B Not Used C 4+2/Standard/1900/1400 ✓ ✓ (2) ✓ (4) ✓ ✓ D Not Used E Ademco Contact ID ✓ ✓ ✓ F Not Used (1) With 685-8 Line Card with Rev 4.4d software. (2) With 9002 Line Card Rev 9035 software or 9032 Line Card with 9326A software. (3) Rev. 4.0 software. (4) FBI CP220FB Rec-11 Line Card with Rev 2.6 software and a memory card with Rev 3.8 software. (5) Model 6500 with Rev 600 software. (6) Model 6000 with Rev 204 software. (7) With Rev B control card at Rev 1.4 software and Rev C line card at Rev 1.5 software. (8) Model 2 only. We try to keep our product information up-to-date and accurate. We cannot cover specific applications or anticipate DF -51294 all requirements. All specifications are subject to change without notice. For more information, contact FIiG LIT@' Page 2 of 2 GENERAL The Fire•Lite LCD -40 is a compact, cost-effective, 40 char- acter, backlit LCD Fire Annunciator for use with the MicroScan-9200 Addressable Fire Alarm Control Panel. The LCD -40 is capable of displaying English language text of system point status including: device type, independent point alarm, trouble or supervisory, zone and custom alpha labels programmed into the MS -9200. The LCD -40 also provides system status LEDs to display Power, Alarm, Trouble and Supervisory. Remote control of critical sys- tem functions such as: Reset, Silence, Acknowledge and Drill can be accomplished with the LCD -40. Communications between the MS -9200 and the LCD -40 are accomplished over a serial interface employing the EIA - 485 communication standard. Up to 32 LCD -40s may be connected to the EIA -485 circuit. Annunciators may be powered from the host MS -9200 or remote power supplies (requires filtered, regulated power). FEATURES • English language, 40 character (20 characters x 2 lines) backlit, Liquid Crystal Display. • Control Switches for System Acknowledge, Signal Si- lence, Drill and Reset with enable key. • System status LEDs for Power, Alarm, Trouble and Su- pervisory. • No programming necessary — LCD mimics the MS -9200 display. • Displays device type identifiers, individual point alarm, trouble or supervisory, zone and custom alpha labels. • Time and date display field. • Aesthetically pleasing, semi -flush mount design. • Serial EIA -485 interface for reduced installation cost (see reverse side for wiring diagram). • May be powered by 24 VDC from the host FACP or by remote power supplies (requires filtered, regulated power). • Up to 32 LCD -40s per MS -9200. • Plug-in terminal blocks for ease of installation and ser- vice. • Can be remotely located up to 3,000 feet from host con- trol panel. • Local piezo sounder with alarm and trouble resound. • Mounts to 2-1/8" deep, three -gang electrical box (Fire•Lite P/N 10103 or equivalent). June 27, 1996 B-100 LCD -40 Liquid Crystal Display Fire Annunciator For use with MS -9200 Catalog Section: Annunciators S2424 California State Fire Marshal 7165-0075:158 MEA 16-94-E Vol. III SYSTEMS RLL NORMAL 2:42 A MON 6,16,45 OPERATION The LCD -40 provides the MS -9200 Addressable Fire Alarm Control Panel with low cost point annunciation, displayed in English-language text on a 40 character LCD display. The LCD -40 also provides an array of LEDs to indicate system status, as well as control switches for remote con- trol of critical system functions. The LCD -40 annunciator provides the MS -9200 with up to 32 remote serially connected annunciators. All field wiring terminations on the LCD -40 use removable, compression - type terminal blocks for ease of wiring and circuit testing. Communications between the FACP and the annunciators are accomplished over an EIA -485 serial interface, greatly reducing wire and installation cost over traditional systems. Six wires total are required: two for the EIA -485 communi- cations in (twisted -pair), two for the EIA -485 communica- tions return (twisted -pair from last LCD -40 on loop) and two for 24 VDC regulated power. Dip switches control local functions such as: piezo disable, control switches/key- switch disable, transmit/receive mode. INSTALLATION The LCD -40 can be semi -flush mounted to a 2-1/8" deep, three -gang electrical box (Fire•Lite P/N 10103 or equiva- lent). A control switch key lock is included to prevent un- authorized use of control switches. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite. Phone: (203) 484-7161 FAX: (203) 484-7118 Flre•uTe ALarms 12 Clintonville Road, Northford, Connecticut 06472 ncoraoaTeo ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISQ-9001 Made in the U.S.A. DF -51474 — Page 1 of 2 ORDERING INFORMATION LCD -40 40 character, backlit, English language, LCD Fire Annunciator. DIM -485 ROM1-MS9200 10103 Display Interface Module (necessary to convert EIA -232 output nal mode] for use with LCD -40). PROM kit upgrade includes ROM 73750 or greater (necessary ware releases prior to 73750 for use with LCD -40). Three -gang electrical box, 2-1/8" deep. of MS -9200 to EIA -485 [termi- to update MS -9200s with soft - LCD -40 TERMINAL MODE WIRING ► 3,000 feet to end of EIA -485 loop ► Terminal Mode EIA -485 (2 -wires) 24 VDC (2 -wires) -4143, c'�bbb C-7Om0 e ■ III Terminal Mode EIA -485 return (2 -wires) MS -9200 4 3,000 feet back from end of EIA -485 loop 4 Notes: 1) EIA -485: Maximum of 6,000 feet total cable length from FACP to LCD -40s and back to FACP. Circuit is power -limited. 2) Up to 32 LCD -40s may be used on the EIA -485 circuit. The MS -9200 can power a maximum of five LCD -40s. If additional LCD -40s are connected, the Fire•Lite FCPS-24F may be used to supply additional power. (Power supplies used for this purpose must have their negative terminals commoned together). 3) Between each LCD -40 are four wires: A twisted -shielded pair for data communications and a pair for 24VDC power. The return circuit only requires two wires for data communi- cation supervision, wired from the last LCD -40 on the loop. 4) Each may have ACK/STEP, SIGNAL SILENCE, DRILL and SYSTEM RESET switches. 5) Displays all 198 addressable points of MS -9200. 6) No programming required for LCD -40s. MOUNTING TO BACKBOX Mounting Holes (4) CAUTION! The LCD -40 can ONLY be mounted in a three -gang electrical box with a minimum depth of 2-1/8" (Fire•Lite P/N 10103 or equivalent). The LCD -40 CANNOT be mounted in three gangable electrical switch boxes connected together. 5-9/16" wide x 3-3/4" high x 2-1/8" deep, three -gang electrical box (Fire•Lite P/N 10103 or equivalent). Page 2 of 2 — DF -51474 LCD -40 flange SYSTEMS ALL NORMAL 2842 A MON 6/16/96 :VS 4101, 11rM+wdr 0 V k mm...7 Addressable Modules for MS -9200 C300 Control Module The FireLite C300 Control Mod- ule is used with the MS -9200 to provide a Style B (Class B) Noti- fication Appliance Circuit (NAC). Alternately, the C300 may be con- verted to an addressable Form -C relay by removing a break off tab. Features Include: S2424 C300 • Internal circuitry and relay powered directly by 2 -wire SLC loop. NAC configuration uses second loop for Notification appliance power. • Integral LED blinks each time it communicates with the MS -9200 and latches on in alarm. • Mounts in standard 4 -inch square (2-1/8" deep) junction box. • Direct dial entry of decade address (01-99). Used to switch 24 VDC audible/visual power or as Form -C relay. May be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset 4 - wire smoke detector power. Specifications: Operating voltage: 15-28 VDC (Peak). Maximum current in alarm: (refer to the MS -9200 Technical Manual). Standby current: 200 µA maximum. Contact rating: 2.0 amps @ 30 VDC (resistive). 1.0 amps @ 30 VDC (inductive, 0.6 PF); 0.3 amps @ 110 VAC (0.35 PF); 0.6 amps @ 30 VDC (pilot duty, 0.35 PF). Temperature range: 32°F. to 120°F. Humidity range: 10% to 95% relative. Weight: 150 grams (5 oz.). Ordering Information: C300 Addressable Control Module. SMB500 Optional surface mount backbox. 12 Clintonville Road Fire•LITe ALarms Northford, CT 06472 rlcorporaTeo Phone: (203) 484-7161 FAX: (203) 484-7118 Califomia State Fire Marshal 7300-0075:159 7300-0075:162 M EA 3-94-E 16-94-E (M302) E300 Fault Isolator Module The I300 Fault Isolator Module is used with the MS -9200 to pro- tect the system against wire -to - wire short circuits on the SLC loop. It is required for Style 7 operation. Features Include: BOO • Powered by SLC loop directly, no external power required. • Mount in standard 4 -inch square (2-1/8" deep) junction boxes. • Integral LED blinks to indicate normal condition. Illuminates steady when short circuit condition is de- tected. • High noise (EMF/RFI) immunity. The Fault Isolator Modules should be placed between groups of devices on the SLC loop, to isolate short circuit problems between the groups so that other de- vices can continue to operate normally. Specifications: Operating voltage: 15-28 VDC (peak). Maximum current in alarm: (refer to the MS -9200 Tech- nical Manual. Standby current: 400 µA maximum. Temperature range: 32°F. to 120°F. Relative humidity: 10% to 95%. Weight: 150 grams (5 oz.) Ordering Information: I300 Isolator Module SMB500 Optional surface mount backbox. ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 Made in the U.S.A. DF -51339 Page 1 of 2 May 03, 1994 Monitor Modules for the MS -9200 • Built-in type identification automatically identifies this • Direct dial entry of decade address (01-99). device as a monitor module to the control panel. • High noise (EMI/RFT) immunity. • High noise (EMF/RFI) immunity. • Two rotary switches for direct dial entry of decade • LED flashes during normal operation and latches on in address (01-99). alarm. M301 Mini -Monitor Module Though the M301 can be used to moni- tor an entire Class B initiating circuit, it is ideally suited for monitoring single devices. The M301 is small enough to fit inside a single gang junction box behind the device being monitored. The small size and light weight allow it to be installed without the need to be rigidly mounted. • Tinned, stripped leads for ease of wiring. • Standby current: 200 µA Use to monitor a single device or a zone of 4 -wire smoke detectors, manual fire alarm pull stations, waterflow de- vices per local authority, or other nor- mally open dry -contact devices. May also be used to monitor normally open supervisory devices with special su- pervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Cass B) Initiating Device Circuit. A 47 kS2 End -of -Line Resistor (provided) ter- minates the circuit (maximum IDC loop resistance 20 S2). To a 2 -wire Class -B initiating circuit To MS -9200 Addressable Loop M302 Monitor Module Two -wire Conventional Smoke Detector Interface The M302 Monitor Module is used with the MS -9200 to monitor a single Initiat- ing Device Circuit (IDC). • Supports compatible two -wire smoke detectors. • Supervises IDC wiring and connection of external power source. • SEMS screws with clamping plates for ease of wiring. • Built-in magnetic alarm test switch. • Mount in standard 4 -inch square (2-1/8" deep) junction boxes. • Standby current 8 mA • Maximum alarm current: 90 mA • M02-04-00 Test Magnet. Use to monitor a zone of 2 -wire smoke detectors. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 kS2 End -of -Line Resistor (provided) terminates the end of the Style B or D (Class B or A) circuit (maximum IDC loop resistance is 25 S2). M300 and M302 M300 Monitor Module The M300 Monitor Module is used with the MS -9200 to monitor a single Initiating Device Circuit (IDC) of normally -open contact devices. • SEMS screws with clamping plates for ease of wiring. • Built-in magnetic alarm test switch. • Mount in standard 4 -inch square (2- 1/8" deep) junction boxes. • M02-04-00 Test Magnet Use to monitor a zone of 4 -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally open dry -contact alarm activation devices. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class D) Initiating Device Circuit. A 47 kS2 End -of -Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. Maximum IDC loop length is 2,500 feet (40 12 maxi- mum). ami CAUTION ODORIMIL 1•14110 !MGM Cover plate for C300, M300, M302 and 1300 We try to keep our product information up-to-date and accurate. We cannot cover specific applications or anticipate alll DF -51339 Fire uTe• requirements. All specifications are subject to change without notice. For more information, contact SD300/SD300T Addressable Photoelectric Detectors GENERAL The SD300 and SD300T Addressable Photoelectric Detec- tors are used with the FireLite MS -9200 Addressable Fire Alarm Control Panel. Since these detectors are addressable, they will help firemen to more quickly locate a fire during its early stages. The SD300T offers the same features as the SD300 with the addition of a 135° F internal thermal element. FEATURES • Unique optical sensing chamber. • Optional integral 135° F. (58° C.) fixed temperature thermal detector. (SD300T) • Superior signal-to-noise ratio. • Stable photoelectric operation. • 1.6% nominal sensitivity for panel alarm threshold level. • Fully coated circuit boards and superior RF/transient protection. • Addressable by device. • Direct DECADE 01-99 entry of address. • 2 -Wire loop connection. • Visible LED "blinks" every time the unit is addressed, and illuminate steady on alarm. • Integral communications and built-in device type identi- fication. • Compact, stylish design. • Built-in functional test switch activated push -in pin type switch. • Low standby current. • Listed to UL -268. • Built-in tamper-resistant feature. • Designed for Direct Surface or Electrical Box Mounting. • Sealed against back pressure. • Removable terminal block. • Easy wiring via removable 6 -pin terminal block allows for detector to be removed from system without loss of power to remaining loop. • Mounts to single gangbox, a 3.5" or 4" octagonal box, a 4" square electrical box by using a plaster ring. Fire•llre Alarms IncorporaTeD 12 Clintonville Road Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 S1059 California State Fire Marshal MEA 7272-0075:157 3-94-E(SD300) (SD300 only) 326-94-E (SD300T) • Plugs into separate base for ease of installation and main- tenance. • 94 -VO plastic flammability rating. • Removable cover and insect screen for field cleaning. • Remote LED output connection. ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 DF -51320 Page 1 012 January 24, 1995 Made In the U.S.A. APPLICATIONS Photoelectric detectors are often faster than ionization de- tectors in sensing smoke from slow smoldering fires. Ion- ization detectors are often better than photoelectric detec` tors at sensing fast, flaming fires. CONSTRUCTION These detectors are constructed of Lexan® in an off-white color. The SD300 plug-in series of smoke detectors is designed to commercial standards and offers an attractive appearance. INSTALLATION The SD300 Series Plug -In Detectors use a separate base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches deep. Suit- able boxes include: • 4 inch square box with plaster ring. • 4 inch octagon box. • 3.5 inch octagon box. • Single gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring "T -taps" or branches are permitted for Style 4 (Class "B") wiring. OPERATION Each SD300/SD300T uses one of 99 possible addresses on the SLC loop. It responds to regular polls from the control panel and reports its type and status. It blinks its LED when polled, and turns the LED on when commanded by the panel. The detector uses the light scattering principle. It represents the latest in smoke sensing technology. COMMON SPECIFICATIONS Voltage Range: 15 - 28 VDC (peak) Standby Current: 15011A @ 24 VDC LED Current: Air Velocity: Diameter: Height: Temperature: Relative Humidity: 7 mA @ 24 VDC (latched "ON") 3000 Ft/Minute (15 m/S) Max 5.0 inches (12.7 cm) 3.0 inches (7.6 cm) 0°- 49°C (32°- 120°F) 10% - 93% Non -condensing SD300T SPECIFICATIONS Includes 135° F. (58° C.) fixed temperature ment. thermal ele- PRODUCT LINE INFORMATION Model Description SD300 Addressable Photoelectric Sensor with base and removable terminal block. SD300T Addressable Photoelectric Sensor with built-in 135° F. (58° C.) fixed temperature thermal element. RA400Z Remote LED. Mounts to a Single gang box. We try to keep our product information up-to-date and accurate. We cannot cover specific applications or anticipate all OF -51320 requirements. All specifications are subject to change without notice. For more information, contact FIre�LITe• • SMITH FIRE SYSTEMS, INC. 1106 .54th Avenue East • Tacoma, Washington 98424 (206) 926-1880 • FAX (206) 926-2350 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME HOMESTEAD VILLAGE JOB NO. R 305 DATE 6/23/97 ADDRESS 15635 WEST VALLEY HIGHWAY BY BOSKOVICH TUKWILA, WASHINGTON SYSTEM DESIGNATION: DRY -ATTIC HAZARD DESCRIPTION: UNUSED ATTIC HAZARD CLASS PER NFPA 13 : LIGHT HAZARD SPECIFIC RULING: ORDINARY HAZARD GROUP 1 RULING MADE BY: CHIEF OLIVIS OF CITY OF TUKWILA DENSITY: .15 GPM OVER THE MOST HYDRAULICALLY REMOTE 1,950 SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: INSIDE HOSE 0 GPM OUTSIDE HOSE 250 GPM IN -RACK SPRINKLER DEMAND GPM SYSTEM TYPE: DRY "C" FACTOR OVERHEAD : 100 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: 130 SPRINKLER MANUFACTURER: RELIABLE MODEL: G K -FACTOR: 5.62 NODE 1, CONNECTION TO YARD MAIN. TOTAL NUMBER OF SPRINKLERS THIS SYSTEM 188 "C" FACTOR UNDERGROUND : 140 SQUARE FEET TEMPERATURE: 212 ° F ORIFICE SIZE: 1/2" WATER SUPPLY: STATIC 147 PSI RESIDUAL 100 PSI FLOW 1,300 GPM ELEVATION OF TEST: SAME AS SITE. DATE OF TEST: DATA PROVIDED BY: CITY OF TUKWILA WATER DEPARTMENT LOCATION OF TEST: HYDRANT #114 AT STRANDER ST. & WEST VALLEY HIGHWAY. BASE OF RISER DEMAND 444.90 GPM REQUIRED AT 104.46 PSI (INCLUDING 0 GPM FOR HOSE STREAMS) SUMMARY 694.90 GPM REQUIRED AT 114.93 PSI AT CONNECTION TO CITY MAIN. (INCLUDING 250 GPM FOR TOTAL HOSE STREAMS) all*:1 11:1=211.9! 5F5 SMITH FIRE SYSTEMS, INC. WATER SUPPLY DATA STATIC 147 PSI RESIDUAL 100 PSI FLOWING 1300 GPM JOB NAME ADDRESS JOB NO. SYSTEM/AREA HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WA R-305 DRY - ATTIC 160 140 120 ■ ■1 FAL,__; ` __i i lr, C 1 1 100 80 60 40 20 0 01 2 3 4 5 6 VOLUME IN GPM X 200 l -�■�C■■ :1�■ SYSTEM DEMAND @ CITY CONNECTION 694.90 GPM AT 114.93 PSI (INCLUDES 250 GPM FOR HOSE STREAMS) SYSTEM DEMAND @ BASE OF RISER 444.90 GPM AT 104.46 PSI (INCLUDES 0 GPM FOR HOSE STREAMS) 7 8 9 10 0 m 0 m SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA SMITH FIRE SYSTEMS, INC. 1106 54TH AVENUE EAST TACOMA, WASHINGTON 98424 1-(253)-926-1880 FLOW TEST RESULTS Water Supply STATIC 147.00 PSI RESIDUAL 100.00 PSI @ 1300.00 GPM CITY PRESSURE AVAILABLE AT 694.9 GPM 132.25 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 521 22.09 19.50 5.62 15.45 522 21.60 19.50 5.62 14.77 523 20.97 19.50 5.62 13.92 524 20.21 19.50 5.62 12.94 525 20.92 19.50 5.62 13.86 526 21.09 19.50 5.62 14.08 527 20.98 19.50 5.62 13.93 528 21.69 19.50 5.62 14.90 529 22.42 19.50 5.62 15.92 530 19.50 19.50 5.62 12.04 531 20.09 19.50 5.62 12.78 532 21.15 19.50 5.62 14.17 533 21.09 19.50 5.62 14.08 534 20.78 19.50 5.62 13.68 535 21.32 19.50 5.62 14.40 536 21.55 19.50 5.62 14.70 537 21.35 19.50 5.62 14.43 538 21.22 19.50 5.62 14.26 539 21.04 19.50 5.62 14.02 540 21.81 19.50 5.62 15.06 541 22.02 19.50 5.62 15.35 06-23-1997 PAGE 1 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 1 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 602 TO 400 444.90 GPM 250.00 GPM 694.90 GPM 114.92 PSI 0.00 PSI 16.18 FPS 06-23-1997 PAGE 2 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 3 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 430 530 1.049 L 10.25 C=100 PT 12.04 (530) Q 19.50 F=T F 4.00 PE 4.44 SG2 T 14.25 0.1740 PF 2.48 410 430 1.049 L 4.50 C=100 PT 18.96 (430) Q 19.50 F=T F 4.00 PE 0.00 AO3 T 8.50 0.1740 PF 1.48 PT 20.44 (410) 440 540 1.049 L 7.13 C=100 PT 15.06 (540) Q 21.81 F=T F 4.00 PE 3.09 SG2 T 11.13 0.2140 PF 2.38 409 440 1.049 L 3.33 C=100 PT 20.53 (440) Q 21.81 F=T F 4.00 PE 0.00 AO3 T 7.33 0.2140 PF 1.57 408 409DQ 22.02 3.352 L 7.00 C=100 PT 22.10 (409) Q 43.83 F=0 F 0.00 PE 0.00 NC1 T 7.00 0.0027 PF 0.02 407 408DQ 85.16 3.352 L 6.50 C=100 PT 22.12 (408) Q 128.99 F=0 F 0.00 PE 0.00 NC1 T 6.50 0.0200 PF 0.13 406 407DQ 63.19 3.352 L 9.00 C=100 PT 22.25 (407) Q 192.18 F=0 F 0.00 PE 0.00 NC1 T 9.00 0.0419 PF 0.38 405 406DQ 104.87 3.352 L 7.00 C=100 PT 22.63 (406) Q 297.05 F=0 F 0.00 PE 0.00 NC T 7.00 0.0937 PF 0.66 404 405DQ 147.85 3.352 L 54.00 C=100 PT 23.29 (405) Q 444.90 F=0 F 0.00 PE 0.00 NC T 54.00 0.1978 PF 10.68 403 404 3.352 L 46.00 C=100 PT 33.97 (404) Q 444.90 F=0 F 0.00 PE 0.00 NC T 46.00 0.1978 PF 9.10 402 403 3.352 L 48.00 C=100 PT 43.07 (403) Q 444.90 F=0 F ' 0.00 PE 0.00 NC T 48.00 0.1978 PF 9.49 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 4 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 401 402 3.352 L 49.00 C=100 PT 52.56 (402) Q 444.90 F=0 F 0.00 PE 0.00 NC T 49.00 0.1978 PF 9.69 400 401 3.352 L 38.00 C=100 PT 62.25 (401) Q 444.90 F=3E F 33.00 PE 0.00 NC T 71.00 0.1978 PF 14.04 602 400 3.352 L 27.00 C=100 PT 76.29 (400) Q 444.90 F=T,2E F 45.00 PE 8.85 NC T 72.00 0.1978 PF 14.24 PT 99.38 (602) 441 541 409 441 Q 22.02 Q 22.02 439 539 438 439 Q 21.04 Q 21.04 1.049 L 7.13 C=100 PT 15.35 (541) F=T F 4.00 PE 3.09 SG2 T 11.13 0.2178 PF 2.42 1.049 L 1.67 C=100 PT 20.86 (441) F=T F 4.00 PE 0.00 A03 T 5.67 0.2178 PF 1.23 PT 22.09 (409) 1.049 L 5.58 C=100 PT 14.02 (539) F=T F 4.00 PE 2.42 SG2 T 9.58 0.2003 PF 1.92 1.752 L 10.50 C=100 PT 18.36 (439) F=E F 6.00 PE 0.00 BN2 T 16.50 0.0165 PF 0.27 PT 18.63 (438) 438 538 1.049 L 5.58 C=100 PT 14.26 (538) Q 21.22 F=T F 4.00 PE 2.42 SG2 T 9.58 0.2035 PF 1.95 414 438DQ 21.04 1.752 L 10.00 C=100 PT 18.63 (438) Q 42.27 F=0 F 0.00 PE 0.00 BN2 T 10.00 0.0599 PF 0.60 PT 19.23 (414) 437 537 1.049 Q 21.35 SG2 L 5.25 C=100 PT 14.43 (537) F=T F 4.00 PE 2.27 T 9.25 0.2057 PF 1.90 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 5 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 414 437 1.049 L 3.00 C=100 PT 18.60 (437) Q 21.35 F=0 F 0.00 PE 0.00 A03 T 3.00 0.2057 PF 0.62 408 414DQ 42.27 1.752 L 4.67 C=100 PT 19.22 (414) Q 63.62 F=T/E F 18.00 PE 0.00 BN2 T 22.67 0.1276 PF 2.89 PT 22.11 (408) 436 536 1.049 L 5.25 C=100 PT 14.70 (536) Q 21.55 F=T F 4.00 PE 2.27 SG2 T 9.25 0.2093 PF 1.94 408 436 1.049 L 10.33 C=100 PT 18.91 (436) Q 21.55 F=T/E F 5.00 PE 0.00 A03 T 15.33 0.2093 PF 3.21 PT 22.12 (408) 435 535 1.049 L 5.56 C=100 PT 14.40 (535) Q 21.32 F=T F 4.00 PE 2.41 SG2 T 9.56 0.2053 PF 1.96 434 435 1.752 L 11.75 C=100 PT 18.77 (435) Q 21.32 F=E F 6.00 PE 0.00 BN2 T 17.75 0.0169 PF 0.30 PT 19.07 (434) 434 534 1.049 L 7.33 C=100 PT 13.68 (534) Q 20.78 F=T F 4.00 PE 3.18 SG2 T 11.33 0.1958 PF 2.22 433 434DQ 21.32 1.752 L 10.75 C=100 PT 19.08 (434) Q 42.11 F=E F 6.00 PE 0.00 BN2 T 16.75 0.0595 PF 1.00 PT 20.08 (433) 433 533 1.049 L 8.17 C=100 PT 14.08 (533) Q 21.09 F=T F 4.00 PE 3.54 SG2 T 12.17 0.2011 PF 2.45 407 433DQ 42.11 1.752 L 5.33 C=100 PT 20.07 (433) Q 63.19 F=T F 12.00 PE 0.00 BN2 T, 17.33 0.1260 PF 2.18 PT 22.25 (407) SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 6 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 432 532 1.049 L 5.58 C=100 PT 14.17 (532) Q 21.15 F=T F 4.00 PE 2.42 SG2 T 9.58 0.2022 PF 1.94 412 432 1.049 L 1.50 C=100 PT 18.53 (432) Q 21.15 F=T F 4.00 PE 0.00 AO3 T 5.50 0.2022 PF 1.11 500 412 1.752 L 10.00 C=100 PT 19.64 (412) Q 21.15 F=0 F 0.00 PE 0.00 BN2 T 10.00 0.0166 PF 0.17 411 500 1.752 L 4.00 C=100 PT 19.81 (500) Q 21.15 F=0 F 0.00 PE 0.00 BN2 T 4.00 0.0166 PF 0.07 PT 19.88 (411) 431 531 1.049 L 7.75 C=100 PT 12.78 (531) Q 20.09 F=T F 4.00 PE 3.36 SG2 T 11.75 0.1839 PF 2.16 411 431 1.049 L 4.50 C=100 PT 18.30 (431) Q 20.09 F=T F 4.00 PE 0.00 AO3 T 8.50 0.1839 PF 1.56 410 411DQ 21.15 1.752 L 10.00 C=100 PT 19.86 (411) Q 41.25 F=0 F 0.00 PE 0.00 BN2 T 10.00 0.0572 PF 0.57 406 410DQ 19.50 1.752 L 6.67 C=100 PT 20.43 (410) Q 60.75 F=T F 12.00 PE 0.00 BN2 T 18.67 0.1171 PF 2.19 PT 22.62 (406) 429 529 1.049 L 5.88 C=100 PT 15.92 (529) Q 22.42 F=T F 4.00 PE 2.55 SG2 T 9.88 0.2253 PF 2.23 510 429 1.752 L 5.50 C=100 PT 20.70 (429) Q 22.42 F=E F 6.00 PE 0.00 BN2 T 11.50 0.0185 PF 0.21 428 510 1.752 ' L 11.00 C=100 PT 20.91 (510) Q 22.42 F=0 F 0.00 PE 0.00 BN2 T 11.00 0.0185 PF 0.20 PT 21.11 (428) SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 7 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 428 528 1.049 L 8.38 C=100 PT 14.90 (528) Q 21.69 F=T F 4.00 PE 3.59 SG2 T 12.38 0.2119 PF 2.62 406 428DQ 22.42 1.752 L 11.33 C=100 PT 21.11 (428) Q 44.12 F=T F 12.00 PE 0.00 BN2 T 23.33 0.0648 PF 1.51 PT 22.62 (406) 427 527 1.049 L 5.88 C=100 PT 13.93 (527) Q 20.98 F=T F 4.00 PE 2.55 SG2 T 9.88 0.1992 PF 1.97 426 427 1.752 L 10.00 C=100 PT 18.45 (427) Q 20.98 F=0 F 0.00 PE 0.00 BN2 T 10.00 0.0164 PF 0.16 PT 18.61 (426) 426 526 1.049 L 5.88 C=100 PT 14.08 (526) Q 21.09 F=T F 4.00 PE 2.55 SG2 T 9.88 0.2011 PF 1.99 425 426DQ 20.98 1.752 L 10.00 C=100 PT 18.62 (426) Q 42.06 F=0 F 0.00 PE 0.00 BN2 T 10.00 0.0593 PF 0.59 PT 19.21 (425) 425 525 1.049 L 7.21 C=100 PT 13.86 (525) Q 20.92 F=T F 4.00 PE 3.12 SG2 T 11.21 0.1982 PF 2.22 424 425DQ 42.06 1.752 L 8.00 C=100 PT 19.20 (425) Q 62.98 F=0 F 0.00 PE 0.00 BN2 T 8.00 0.1252 PF 1.00 PT 20.20 (424) 424 524 Q 20.21 405 424DQ Q 1.049 L 10.54 C=100 PT 12.94 (524) F=T F 4.00 PE 4.57 SG2 T 14.54 0.1859 PF 2.70 62.98 1.752 L 2.67 C=100 PT 20.21 (424) 83.20 F=T F, 12.00 PE 0.00 BN2 T 14.67 0.2096 PF 3.07 PT 23.28 (405) SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 8 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 423 523 1.049 L 5.88 C=100 PT 13.92 (523) Q 20.97 F=T F 4.00 F1 4.73 SG2 T 9.88 0.1990 PF 1.97 422 423 1.752 L 10.00 C=100 PT 20.62 (423) Q 20.97 F=0 F 0.00 PE 0.00 BN2 T 10.00 0.0164 PF 0.16 PT 20.78 (422) 422 522 1.049 L 8.04 C=100 PT 14.77 (522) Q 21.60 F=T F 4.00 PE 3.48 SG2 T 12.04 0.2102 PF 2.53 421 422DQ 20.97 1.752 L 8.00 C=100 PT 20.78 (422) Q 42.56 F=0 F 0.00 PE 0.00 BN2 T 8.00 0.0607 PF 0.49 PT 21.27 (421) 421 521 Q 22.09 405 421DQ Q 1.049 L 10.92 C=100 PT 15.45 (521) F=T F 4.00 PE 2.55 SG2 T 14.92 0.2191 PF 3.27 42.56 1.752 L 3.33 C=100 PT 21.27 (421) 64.65 F=T F 12.00 PE 0.00 BN2 T 15.33 0.1314 PF 2.01 PT 23.28 (405) 601 602 600 601 6 600 5 6 Q 444.90 Q 444.90 Q 444.90 Q 444.90 4.352 L 2.00 C=100 PT 99.38 (602) F=0 F 0.00 PE 0.87 FR2 T 2.00 0.0555 PF 0.11 4.352 L 0.01 C=100 PT 100.36 (601) F=10/0 F 10.00 PE 0.54 FR2 T 10.01 0.0555 PF 0.56 4.352 L 5.63 C=120 PT 101.46 (600) F=T,E,GV F 47.00 PE 0.92 FR2 T 52.63 0.0396 PF 2.08 4.352 L 0.92 C=120 PT 104.46 ( 6) F=0 F 0.00 PE 0.40 FR1 T , 0.92 0.0396 PF 0.04 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 9 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 4 5 3 4 Q 444.90 Q 444.90 4.095 UN3 6.155 L 31.00 C=140 PT 104.90 ( 5) F=0/E F 9.00 PE 1.72 T 40.00 0.0400 PF 1.60 L 15.00 C=140 PT 108.22 ( 4) F=EE,GV F 14.00 PE 0.00 UN2 T 29.00 0.0055 PF 0.16 2 3 6.155 L 0.01 C=140 PT 108.38 ( 3) Q 444.90 F=0 F 0.00 PE 5.00 UN2 T 0.01 0.0055 PF 0.00 COMMENT: 6" WILKINS 950 DA DCVA. 5 PSI LOSS AT 500 GPM OR LESS 1 2 6.155 L 5.00 C=140 PT 113.38 ( 2) Q 444.90 F=T,GV F 47.00 PE 0.00 UN2 T 52.00 0.0055 PF 0.29 COMMENT: 250 GPM OUTSIDE HOSE ADDED AT HYDRANT CONNECTION. 0 1DQ 250.00 8.265 Q 694.90 UN1 L 305.00 C=140 PT 113.67 ( 1) F=2T,2GV F 116.00 PE 0.00 T 421.00 0.0030 PF 1.26 PT 114.93 ( 0) SMITH FIRE SYSTEMS, INC. JOB NO. R-305 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WA. SYSTEM # ONE UNUSED ATTIC AUXILIARY HYDRAULIC CALCULATION DESIGN DENSITY: .15 GPM / 1,950 SQ. FT. SYSTEM DEMAND AT BASE OF RISER 402.86 GPM AT 89.49 PSI AUXILIARY SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA SMITH FIRE SYSTEMS, INC. 1106 54TH AVENUE EAST TACOMA, WASHINGTON 98424 FLOW TEST RESULTS Water Supply STATIC 147.00 PSI RESIDUAL 100.00 PSI @ 1300.00 GPM CITY PRESSURE AVAILABLE AT 652.9 GPM 133.86 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 571 22.35 19.50 5.62 15.82 572 21.35 19.50 5.62 14.44 573 20.87 19.50 5.62 13.80 574 20.72 19.50 5.62 13.59 575 22.15 19.50 5.62 15.54 576 21.20 19.50 5.62 14.24 577 20.75 19.50 5.62 13.63 578 20.60 19.50 5.62 13.44 579 20.92 19.50 5.62 13.86 580 20.05 19.50 5.62 12.73 581 19.64 19.50 5.62 12.21 582 19.50 19.50 5.62 12.04 583 24.72 19.50 5.62 19.34 584 19.71 19.50 5.62 12.29 585 20.67 19.50 5.62 13.53 586 21.25 19.50 5.62 14.30 587 21.77 19.50 5.62 15.00 588 21.28 19.50 5.62 14.34 589 23.35 19.50 5.62 17.26 06-23-1997 PAGE 1 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 1 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 450 TO 451 402.86 GPM 250.00 GPM 652.86 GPM 99.47 PSI 0.00 PSI 16.37 FPS 06-23-1997 PAGE 2 AUXILIARY SUBMITTAL SERIAL NO:2244HY1. HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 3 FROM TO FLOW LENGTH FITTING DIAM TYPE PSI/Ft S -LOSS PRESSURES 482 582 19.50 10.33 4.0 1.049 SG1 0.174 4.48 19.01 12.04 481 482 19.50 14.00 0.0 1.752 BN1 0.014 0.00 19.21 19.01 483 583 24.72 10.33 4.0 1.049 SG1 0.270 4.48 27.69 19.34 449 483 24.72 44.00 12.0 1.752 BN1 0.022 0.00 28.93 27.69 404 449 24.72 3.13 23.0 3.352 NC2 0.001 0.00 28.95 28.93 403 404 402.86 46.00 0.0 3.352 NC 0.165 0.00 36.52 28.95 402 403 402.86 48.00 0.0 3.352 NC 0.165 0.00 44.42 36.52 401 402 402.86 49.00 0.0 3.352 NC 0.165 0.00 52.49 44.42 400 401 402.86 38.00 33.0 3.352 NC 0.165 0.00 64.18 52.49 602 400 402.86 27.00 45.0 3.352 NC 0.165 8.85 84.88 64.18 489 589 23.35 5.54 4.0 1.049 SG1 0.243 2.40 21.98 17.26 457 489 23.35 8.00 12.0 1.752 BN1 0.020 0.00 22.38 21.98 456 457 23.35 4.17 0.0 2.727 NC2 0.002 0.00 22.39 22.38 455 456 108.65 4.25 0.0 2.727 NC2 0.040 0.00 22.56 22.39 454 455 129.93 2.50 0.0 2.727 NC2 0.055 0.00 22.70 22.56 453 454 151.70 2.50 0.0 2.727 NC2 0.074 0.00 22.88 22.70 452 453 236.41 2.25 0.0 2.727 NC2 0.168 0.00 23.26 22.88 451 452 257.66 6.17 0.0 2.727 NC2 0.197 0.00 24.47 23.26 450 451 298.04 0.83 0.0 2.727 NC2 0.257 0.00 24.68 24.47 404 450 378.14 6.13 23.0 3.352 NC2 0.146 0.00 28.94 24.68 488 588 21.28 9.04 4.0 1.049 SG1 0.205 3.92 20.93 14.34 455 488 21.28 4.00 4.0 1.049 AOl 0.205 0.00 22.57 20.93 487 587 21.77 10.04 4.0 1.049 SG1 0.213 4.35 22.34 15.00 454 487 21.77 8.00 12.0 1.752 BN1 0.018 0.00 22.69 22.34 486 586 21.25 12.00 4.0 1.049 SG1 0.204 5.20 22.76 14.30 452 486 21.25 6.00 10.0 1.542 A02 0.031 0.00 23.26 22.76 485 585 20.67 14.58 4.0 1.049 SG1 0.194 6.32 23.45 13.53 460 485 20.67 2.00 0.0 1.752 BN1 0.016 0.00 23.48 23.45 484 584 19.71 15.42 4.0 1.049 SG1 0.177 6.68 22.42 12.29 460 484 19.71 2.00 4.0 1.049 AOl 0.177 0.00 23.48 22.42 451 460 40.38 6.00 12.0 1.752 BN1 0.055 0.00 24.47 23.48 481 581 19.64 10.33 4.0 1.049 SG1 0.176 4.48 19.21 12.21 480 481 39.14 12.00 0.0 1.752 BN1 0.052 0.00 19.83 19.21 480 580 20.05 10.33 4.0 1.049 SG1 0.183 4.48 19.84 12.73 479 480 59.19 12.00 0.0 1.752 BN1 0.112 0.00 21.18 19.84 479 579 20.92 10.33 4.0 1.049 SG1 0.198 4.48 21.18 13.86 450 479 80.11 6.00 12.0 1.752 BN1 0.195 0.00 24.70 21.18 AUXILIARY SUBMITTAL SERIAL NO:2244H h HOMESTEAD VILLAGE R-305 DRY SYSTEM-UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA FROM TO FLOW LENGTH FITTING DIAM TYPE 478 578 477 478 20.60 6.46 4.0 1.049 SG1 20.60 14.00 0.0 1.752 BN1 477 577 476 477 20.75 6.46 4.0 1.049 SG1 41.35 12.00 0.0 1.752 BN1 476 576 475 476 21.20 6.46 4.0 1.049 SG1 62.55 12.00 0.0 1.752 BN1 475 575 453 475 22.15 6.46 4.0 84.71 6.00 12.0 474 574 20.72 2.63 4.0 473 474 20.72 14.00 0.0 473 573 20.87 2.63 4.0 472 473 41.59 12.00 0.0 472 572 21.35 2.63 4.0 471 472 62.94 12.00 0.0 471 571 456 471 22.35 2.63 4.0 85.30 6.00 12.0 601 602 600 601 6 600 5 6 4 5 3 4 2 3 COMMENT: 1 2 COMMENT: 0 1 402.86 2.00 0.0 402.86 0.01 10.0 402.86 5.63 47.0 402.86 0.92 0.0 402.86 31.00 9.0 402.86 15.00 14.0 402.86 0.01 0.0 1.049 SG1 1.752 BN1 1.049 SG1 1.752 BN1 1.049 SG1 1.752 BN1 1.049 SG1 1.752 BN1 1.049 SG1 1.752 BN1 4.352 FR2 4.352 FR2 4.352 FR2 4.352 FR1 4.095 UN3 6.155 UN2 6.155 UN2 06-23-1997 PAGE 4 PSI/Ft S -LOSS PRESSURES 0.193 1.14 16.59 13.44 0.016 0.00 16.81 16.59 0.195 1.14 16.81 13.63 0.058 0.00 17.50 16.81 O .203 1.14 17.51 14.24 0.124 0.00 18.99 17.51 0.220 1.14 18.98 15.54 0.217 0.00 22.88 18.98 0.195 1.14 16.02 13.59 0.016 0.00 16.24 16.02 O .197 1.14 16.25 13.80 O .058 0.00 16.95 16.25 0.206 1.14 16.94 14.44 0.125 0.00 18.44 16.94 0.224 1.14 18.45 15.82 0.220 0.00 22.40 18.45 0.046 0.87 85.84 84.88 0.046 0.54 86.84 85.84 O .033 0.92 89.49 86.84 0.033 0.40 89.92 89.49 O .033 1.72 92.97 89.92 0.005 0.00 93.10 92.97 0.005 5.00 98.10 93.10 6" WILKINS 950 DA DCVA. 5 PSI LOSS AT 500 GPM OR LESS 402.86 5.00 47.0 6.155 UN2 0.005 0.00 98.34 98.10 250 GPM OUTSIDE HOSE ADDED AT HYDRANT CONNECTION. 652.86 305.00 116.0 8.265 UN1 0.003 0.00 99.48 98.34 • • . City of Tukwila Johr W Rants, Mayor Fire Department Thomas P. Keefe, rire C df June 20, 1997 Smith Fire Systems Sprinkler Plan Review Re: Homestead Village - 15635 West Valley Highway Approval of this project is conditional upon completion of the following items: 1) Follow items 1, 4, 5, 7 and 8 of the W.S.R.B. review dated June 13, 1997. 2) No light hazard in the attic. 3) Bathroom fixtures shall be noncombustible. 4) Bracing shall comply with N.F.P.A. 13, 1996, Table 4-14.2.2.1. 5) Riser alarm piping per N.F.P.A. 13, 1996, 2-9.4, 2-9.5. 6) Elevator sprinklers shall be on separate valve. 7) Provide as-builts including the above corrections. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East • Tacoma, Washington 98424 (206) 926-1880 • FAX (206) 926-2350 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME HOMESTEAD VILLAGE JOB NO. R 305 DATE 6/23197 ADDRESS 15635 WEST VALLEY HIGHWAY BY BOSKOVICH TUKWILA, WASHINGTON SYSTEM DESIGNATION: DRY -ATTIC HAZARD DESCRIPTION: UNUSED ATTIC HAZARD CLASS PER NFPA 13 : LIGHT HAZARD SPECIFIC RULING: ORDINARY HAZARD GROUP 1 r FILE 1 RULING MADE BY: CHIEF OLIVIS OF CITY OF TUKWILA DENSITY: .15 GPM OVER THE MOST HYDRAULICALLY REMOTE 1,950 SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: INSIDE HOSE 0 GPM OUTSIDE HOSE 250 GPM NODE 1, CONNECTION TO YARD MAIN. IN -RACK SPRINKLER DEMAND GPM SYSTEM TYPE: DRY "C" FACTOR OVERHEAD : 100 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: 130 SPRINKLER MANUFACTURER: RELIABLE MODEL: G K -FACTOR: 5.62 TOTAL NUMBER OF SPRINKLERS THIS SYSTEM 188 "C" FACTOR UNDERGROUND : 140 SQUARE FEET TEMPERATURE: 212 ° F ORIFICE SIZE: 1/2" WATER SUPPLY: STATIC 147 PSI RESIDUAL 100 PSI FLOW 1,300 GPM ELEVATION OF TEST: SAME AS SITE. DATE OF TEST: DATA PROVIDED BY: CITY OF TUKWILA WATER DEPARTMENT LOCATION OF TEST: HYDRANT #114 AT STRANDER ST. & WEST VALLEY HIGHWAY. BASE OF RISER DEMAND 444.90 GPM REQUIRED AT 104.46 PSI (INCLUDING 0 GPM FOR HOSE STREAMS) SUMMARY 694.90 GPM REQUIRED AT 114.93 PSI AT CONNECTION TO CITY MAIN. (INCLUDING 250 GPM FOR TOTAL HOSE STREAMS) "T:14:1:1II:1*I I 1. SMITH FIRE SYSTEMS, INC. WATER SUPPLY DATA STATIC 147 PSI RESIDUAL 100 PSI FLOWING 1300 GPM ��w iii.�iiiiiii i ri rrrrrrrrrrr IMO 1111111111111111111M1NEM JOB NAME ADDRESS JOB NO. SYSTEM/AREA HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WA R-305 DRY — ATTIC NEM ..i�iNiiiv=1 iii wommonmmim 160 140 121 100 Nil MINIMUM" II III w=w.ww rrrrorrr II ONO wr.r==MM. MON Ill i 1111 �basiiii■■--III •IT' 11111MMIIII1i us 11.511I---rn .uh --w_rwr�� A�w.rrrr� _____ M E 11!! ::::.. imEi ■wE_____ ��■■_•I 8 0 �w.�w.��wwrrwr.�ww..w. rr�w�n•wwr.—rEr��.wo.ww. 1 WIAT..w. wrw i�wrrwrw��w■►�w.rrrrr■ ... rrw�ww�r�rrwwrw�ww..��w.wr� ..... 60 MOM" A�rrwwtwr...r.rr�w_ .il MIMMMMIIMMICIM .•r.rmom ow...w���r MAIMII IMMIIMIMMOMMOMM rrrw..i�� ..ii� .� ww ���.wrw��rwwNMI IMMO wwMINIM HO EM w MINI IMO=MINIMIMMIMONOM 111 1 MMIMI 1116.11...111=NW M EMIMI MaInks li 40 21 MEI Mr�awww—rw�r.r.ww. NMI ■ruIwMw.rrw�r.r.ww. wn.M.__— __w. IMMIMMINIM sINN mwINIMM www.wwr._w. rn rUMMIIMIM wwww.wwww. M Irall.rw.r.r.r.w. r rrwrwr.ww.w�w�. IIrwr�ww�r.r.w Ir .. .r.arw 0 1111111[11F 01 2 3 1 5 46 VOLUME IN GPM X 200 7 8 9 10 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA SMITH FIRE SYSTEMS, INC. 1106 54TH AVENUE EAST TACOMA, WASHINGTON 98424 1-(253)-926-1880 FLOW TEST RESULTS Water Supply STATIC 147.00 PSI RESIDUAL 100.00 PSI @ 1300.00 GPM CITY PRESSURE AVAILABLE AT 694.9 GPM 132.25 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 521 22.09 19.50 5.62 15.45 522 21.60 19.50 5.62 14.77 523 20.97 19.50 5.62 13.92 524 20.21 19.50 5.62 12.94 525 20.92 19.50 5.62 13.86 526 21.09 19.50 5.62 14.08 527 20.98 19.50 5.62 13.93 528 21.69 19.50 5.62 14.90 529 22.42 19.50 5.62 15.92 530 19.50 19.50 5.62 12.04 531 20.09 19.50 5.62 12.78 532 21.15 19.50 5.62 14.17 533 21.09 19.50 5.62 14.08 534 20.78 19.50 5.62 13.68 535 21.32 19.50 5.62 14.40 536 21.55 19.50 5.62 14.70 537 21.35 19.50 5.62 14.43 538 21.22 19.50 5.62 14.26 539 21.04 19.50 5.62 14.02 540 21.81 19.50 5.62 15.06 541 22.02 19.50 5.62 15.35 06-23-1997 PAGE 1 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 1 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 602 TO 400 444.90 GPM 250.00 GPM 694.90 GPM 114.92 PSI 0.00 PSI 16.18 FPS 06-23-1997 PAGE 2 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 3 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 430 530 1.049 L 10.25 C=100 PT 12.04 (530) Q 19.50 F=T F 4.00 PE 4.44 SG2 T 14.25 0.1740 PF 2.48 410 430 1.049 L 4.50 C=100 PT 18.96 (430) Q 19.50 F=T F 4.00 PE 0.00 A03 T 8.50 0.1740 PF 1.48 PT 20.44 (410) 440 540 1.049 L 7.13 C=100 PT 15.06 (540) Q 21.81 F=T F 4.00 PE 3.09 SG2 T 11.13 0.2140 PF 2.38 409 440 1.049 L 3.33 C=100 PT 20.53 (440) Q 21.81 F=T F 4.00 PE 0.00 A03 T 7.33 0.2140 PF 1.57 408 409DQ 22.02 3.352 L 7.00 C=100 PT 22.10 (409) Q 43.83 F=0 F 0.00 PE 0.00 NC1 T 7.00 0.0027 PF 0.02 407 408DQ 85.16 3.352 L 6.50 C=100 PT 22.12 (408) Q 128.99 F=0 F 0.00 PE 0.00 NC1 T 6.50 0.0200 PF 0.13 406 407DQ 63.19 3.352 L 9.00 C=100 PT 22.25 (407) Q 192.18 F=0 F 0.00 PE 0.00 NC1 T 9.00 0.0419 PF 0.38 405 406DQ 104.87 3.352 L 7.00 C=100 PT 22.63 (406) Q 297.05 F=0 F 0.00 PE 0.00 NC T 7.00 0.0937 PF 0.66 404 405DQ 147.85 3.352 L 54.00 C=100 PT 23.29 (405) Q 444.90 F=0 F 0.00 PE 0.00 NC T 54.00 0.1978 PF 10.68 403 404 3.352 L 46.00 C=100 PT 33.97 (404) Q 444.90 F=0 F 0.00 PE 0.00 NC T 46.00 0.1978 PF 9.10 402 403 3.352 L 48.00 C=100 PT 43.07 (403) Q 444.90 F=0 F 0.00 PE 0.00 NC T 48.00 0.1978 PF 9.49 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 4 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 401 402 3.352 L 49.00 C=100 PT 52.56 (402) Q 444.90 F=0 F 0.00 PE 0.00 NC T 49.00 0.1978 PF 9.69 400 401 3.352 L 38.00 C=100 PT 62.25 (401) Q 444.90 F=3E F 33.00 PE 0.00 NC T 71.00 0.1978 PF 14.04 602 400 3.352 L 27.00 C=100 PT 76.29 (400) Q 444.90 F=T,2E F 45.00 PE 8.85 NC T 72.00 0.1978 PF 14.24 PT 99.38 (602) 441 541 1.049 L 7.13 C=100 PT 15.35 (541) Q 22.02 F=T F 4.00 PE 3.09 SG2 T 11.13 0.2178 PF 2.42 409 441 1.049 L 1.67 C=100 PT 20.86 (441) Q 22.02 F=T F 4.00 PE 0.00 AO3 T 5.67 0.2178 PF 1.23 PT 22.09 (409) 439 539 1.049 L 5.58 C=100 PT 14.02 (539) Q 21.04 F=T F 4.00 PE 2.42 SG2 T 9.58 0.2003 PF 1.92 438 439 1.752 L 10.50 C=100 PT 18.36 (439) Q 21.04 F=E F 6.00 PE 0.00 BN2 T 16.50 0.0165 PF 0.27 PT 18.63 (438) 438 538 1.049 L 5.58 C=100 PT 14.26 (538) Q 21.22 F=T F 4.00 PE 2.42 SG2 T 9.58 0.2035 PF 1.95 414 438DQ 21.04 1.752 L 10.00 C=100 PT 18.63 (438) Q 42.27 F=0 F 0.00 PE 0.00 BN2 T 10.00 0.0599 PF 0.60 PT 19.23 (414) 437 537 1.049 L 5.25 C=100 PT 14.43 (537) Q 21.35 F=T F 4.00 PE 2.27 SG2 T 9.25 0.2057 PF 1.90 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 5 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 414 437 1.049 L 3.00 C=100 PT 18.60 (437) Q 21.35 F=0 F 0.00 PE 0.00 A03 T 3.00 0.2057 PF 0.62 408 414DQ 42.27 1.752 L 4.67 C=100 PT 19.22 (414) Q 63.62 F=T/E F 18.00 PE 0.00 BN2 T 22.67 0.1276 PF 2.89 PT 22.11 (408) 436 536 1.049 L 5.25 C=100 PT 14.70 (536) Q 21.55 F=T F 4.00 PE 2.27 SG2 T 9.25 0.2093 PF 1.94 408 436 1.049 L 10.33 C=100 PT 18.91 (436) Q 21.55 F=T/E F 5.00 PE 0.00 A03 T 15.33 0.2093 PF 3.21 PT 22.12 (408) 435 535 1.049 L 5.56 C=100 PT 14.40 (535) Q 21.32 F=T F 4.00 PE 2.41 SG2 T 9.56 0.2053 PF 1.96 434 435 1.752 L 11.75 C=100 PT 18.77 (435) Q 21.32 F=E F 6.00 PE 0.00 BN2 T 17.75 0.0169 PF 0.30 PT 19.07 (434) 434 534 1.049 Q 20.78 SG2 433 434DQ 21.32 1.752 Q 42.11 BN2 L 7.33 C=100 PT 13.68 (534) F=T F 4.00 PE 3.18 T 11.33 0.1958 PF 2.22 L 10.75 C=100 PT 19.08 (434) F=E F 6.00 PE 0.00 T 16.75 0.0595 PF 1.00 PT 20.08 (433) 433 533 1.049 L 8.17 C=100 PT 14.08 (533) Q 21.09 F=T F 4.00 PE 3.54 SG2 T 12.17 0.2011 PF 2.45 407 433DQ 42.11 1.752 L 5.33 C=100 PT 20.07 (433) Q 63.19 F=T F 12.00 PE 0.00 BN2 T 17.33 0.1260 PF 2.18 PT 22.25 (407) SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 6 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 432 532 1.049 L 5.58 C=100 PT 14.17 (532) Q 21.15 F=T F 4.00 PE 2.42 SG2 T 9.58 0.2022 PF 1.94 412 432 1.049 L 1.50 C=100 PT 18.53 (432) Q 21.15 F=T F 4.00 PE 0.00 A03 T 5.50 0.2022 PF 1.11 500 412 1.752 L 10.00 C=100 PT 19.64 (412) Q 21.15 F=0 F 0.00 PE 0.00 BN2 T 10.00 0.0166 PF 0.17 411 500 1.752 L 4.00 C=100 PT 19.81 (500) Q 21.15 F=0 F 0.00 PE 0.00 BN2 T 4.00 0.0166 PF 0.07 PT 19.88 (411) 431 531 1.049 L 7.75 C=100 PT 12.78 (531) Q 20.09 F=T F 4.00 PE 3.36 SG2 T 11.75 0.1839 PF 2.16 411 431 1.049 L 4.50 C=100 PT 18.30 (431) Q 20.09 F=T F 4.00 PE 0.00 A03 T 8.50 0.1839 PF 1.56 410 411DQ 21.15 1.752 L 10.00 C=100 PT 19.86 (411) Q 41.25 F=0 F 0.00 PE 0.00 BN2 T 10.00 0.0572 PF 0.57 406 410DQ 19.50 1.752 L 6.67 C=100 PT 20.43 (410) Q 60.75 F=T F 12.00 PE 0.00 BN2 T 18.67 0.1171 PF 2.19 PT 22.62 (406) 429 529 1.049 L 5.88 C=100 PT 15.92 (529) Q 22.42 F=T F 4.00 PE 2.55 SG2 T 9.88 0.2253 PF 2.23 510 429 1.752 L 5.50 C=100 PT 20.70 (429) Q 22.42 F=E F 6.00 PE 0.00 BN2 T 11.50 0.0185 PF 0.21 428 510 1.752 L 11.00 C=100 PT 20.91 (510) Q 22.42 F=0 F 0.00 PE 0.00 BN2 T 11.00 0.0185 PF 0.20 PT 21.11 (428) SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 7 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 428 528 1.049 L 8.38 C=100 PT 14.90 (528) Q 21.69 F=T F 4.00 PE 3.59 SG2 T 12.38 0.2119 PF 2.62 406 428DQ 22.42 1.752 L 11.33 C=100 PT 21.11 (428) Q 44.12 F=T F 12.00 PE 0.00 BN2 T 23.33 0.0648 PF 1.51 PT 22.62 (406) 427 527 1.049 L 5.88 C=100 PT 13.93 (527) Q 20.98 F=T F 4.00 PE 2.55 SG2 T 9.88 0.1992 PF 1.97 426 427 1.752 L 10.00 C=100 PT 18.45 (427) Q 20.98 F=0 F 0.00 PE 0.00 BN2 T 10.00 0.0164 PF 0.16 PT 18.61 (426) 426 526 1.049 L 5.88 C=100 PT 14.08 (526) Q 21.09 F=T F 4.00 PE 2.55 SG2 T 9.88 0.2011 PF 1.99 425 426DQ 20.98 1.752 L 10.00 C=100 PT 18.62 (426) Q 42.06 F=0 F 0.00 PE 0.00 BN2 T 10.00 0.0593 PF 0.59 PT 19.21 (425) 425 525 1.049 L 7.21 C=100 PT 13.86 (525) Q 20.92 F=T F 4.00 PE 3.12 SG2 T 11.21 0.1982 PF 2.22 424 425DQ 42.06 1.752 L 8.00 C=100 PT 19.20 (425) Q 62.98 F=0 F 0.00 PE 0.00 BN2 T 8.00 0.1252 PF 1.00 PT 20.20 (424) 424 524 1.049 L 10.54 C=100 PT 12.94 (524) Q 20.21 F=T F 4.00 PE 4.57 SG2 T 14.54 0.1859 PF 2.70 405 424DQ 62.98 1.752 L 2.67 C=100 PT 20.21 (424) Q 83.20 F=T F 12.00 PE 0.00 BN2 T 14.67 0.2096 PF 3.07 PT 23.28 (405) SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 8 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 423 523 422 423 Q 20.97 Q 20.97 422 522 Q 21.60 421 422DQ 20.97 Q 42.56 1.049 SG2 1.752 BN2 L 5.88 C=100 PT 13.92 (523) F=T F 4.00 PE 4.73 T 9.88 0.1990 PF 1.97 L 10.00 C=100 PT 20.62 (423) F=0 F 0.00 PE 0.00 T 10.00 0.0164 PF 0.16 PT 20.78 (422) 1.049 L 8.04 C=100 PT 14.77 (522) F=T F 4.00 PE 3.48 SG2 T 12.04 0.2102 PF 2.53 1.752 L 8.00 C=100 PT 20.78 (422) F=0 F 0.00 PE 0.00 BN2 T 8.00 0.0607 PF 0.49 PT 21.27 (421) 421 521 1.049 L 10.92 C=100 PT 15.45 (521) Q 22.09 F=T F 4.00 PE 2.55 SG2 T 14.92 0.2191 PF 3.27 405 421DQ 42.56 1.752 L 3.33 C=100 PT 21.27 (421) Q 64.65 F=T F 12.00 PE 0.00 BN2 T 15.33 0.1314 PF 2.01 PT 23.28 (405) 601 602 600 601 6 600 5 6 Q 444.90 Q 444.90 Q 444.90 Q 444.90 4.352 L 2.00 C=100 PT 99.38 (602) F=0 F 0.00 PE 0.87 FR2 T 2.00 0.0555 PF 0.11 4.352 L 0.01 C=100 PT 100.36 (601) F=10/0 F 10.00 PE 0.54 FR2 T 10.01 0.0555 PP 0.56 4.352 L 5.63 C=120 PT 101.46 (600) F=T,E,GV F 47.00 PE 0.92 FR2 T 52.63 0.0396 PF 2.08 4.352 L 0.92 C=120 PT 104.46 ( 6) F=0 F 0.00 PE 0.40 FR1 T 0.92 0.0396 PF 0.04 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA Location Flow in From To GPM Pipe Size IN Fittings Devices 4 5 4.095 UN3 3 4 6.155 UN2 2 3 6.155 UN2 COMMENT: 6" WILKINS 950 DA Q 444.90 Q 444.90 Q 444.90 1 2 6.155 Q 444.90 UN2 COMMENT: 250 GPM OUTSIDE 0 1DQ 250.00 8.265 Q 694.90 UNl L F=0/E F T L F=EE,GV F T Equiv Length Ft 31.00 9.00 40.00 15.00 14.00 29.00 Friction Loss PSI/Ft L 0.01 F=0 F 0.00 T 0.01 DCVA. 5 PSI LOSS AT L 5.00 F=T,GV F 47.00 T 52.00 HOSE ADDED AT HYDRANT L 305.00 F=2T,2GV F 116.00 T 421.00 06-23-1997 PAGE 9 Pressure Summary PSI C=140 PT 104.90 ( 5) PE 1.72 0.0400 PF 1.60 C=140 PT 108.22 ( 4) PE 0.00 0.0055 PF 0.16 C=140 PT 108.38 ( 3) PE 5.00 0.0055 PF 0.00 500 GPM OR LESS C=140 PT 113.38 ( 2) PE 0.00 0.0055 PF 0.29 CONNECTION. C=140 PT 113.67 ( 1) PE 0.00 0.0030 PF 1.26 PT 114.93 ( 0) SMITH FIRE SYSTEMS, INC. JOB NO. R-305 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WA. SYSTEM # ONE UNUSED ATTIC AUXILIARY HYDRAULIC CALCULATION DESIGN DENSITY: .15 GPM / 1,950 SQ. FT. SYSTEM DEMAND AT BASE OF RISER 402.86 GPM AT 89.49 PSI AUXILIARY SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA SMITH FIRE SYSTEMS, INC. 1106 54TH AVENUE EAST TACOMA, WASHINGTON 98424 FLOW TEST RESULTS Water Supply STATIC 147.00 PSI RESIDUAL 100.00 PSI @ 1300.00 GPM CITY PRESSURE AVAILABLE AT 652.9 GPM 133.86 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 571 22.35 19.50 5.62 15.82 572 21.35 19.50 5.62 14.44 573 20.87 19.50 5.62 13.80 574 20.72 19.50 5.62 13.59 575 22.15 19.50 5.62 15.54 576 21.20 19.50 5.62 14.24 577 20.75 19.50 5.62 13.63 578 20.60 19.50 5.62 13.44 579 20.92 19.50 5.62 13.86 580 20.05 19.50 5.62 12.73 581 19.64 19.50 5.62 12.21 582 19.50 19.50 5.62 12.04 583 24.72 19.50 5.62 19.34 584 19.71 19.50 5.62 12.29 585 20.67 19.50 5.62 13.53 586 21.25 19.50 5.62 14.30 587 21.77 19.50 5.62 15.00 588 21.28 19.50 5.62 14.34 589 23.35 19.50 5.62 17.26 06-23-1997 PAGE 1 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 1 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 450 TO 451 402.86 GPM 250.00 GPM 652.86 GPM 99.47 PSI 0.00 PSI 16.37 FPS 06-23-1997 PAGE 2 AUXILIARY SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA 06-23-1997 PAGE 3 FROM TO FLOW LENGTH FITTING DIAM TYPE PSI/Ft S -LOSS PRESSURES 482 582 19.50 10.33 4.0 1.049 SG1 0.174 4.48 19.01 12.04 481 482 19.50 14.00 0.0 1.752 BN1 0.014 0.00 19.21 19.01 483 583 24.72 10.33 4.0 1.049 SG1 0.270 4.48 27.69 19.34 449 483 24.72 44.00 12.0 1.752 BN1 0.022 0.00 28.93 27.69 404 449 24.72 3.13 23.0 3.352 NC2 0.001 0.00 28.95 28.93 403 404 402.86 46.00 0.0 3.352 NC 0.165 0.00 36.52 28.95 402 403 402.86 48.00 0.0 3.352 NC 0.165 0.00 44.42 36.52 401 402 402.86 49.00 0.0 3.352 NC 0.165 0.00 52.49 44.42 400 401 402.86 38.00 33.0 3.352 NC 0.165 0.00 64.18 52.49 602 400 402.86 27.00 45.0 3.352 NC 0.165 8.85 84.88 64.18 489 589 23.35 5.54 4.0 1.049 SG1 0.243 2.40 21.98 17.26 457 489 23.35 8.00 12.0 1.752 BN1 0.020 0.00 22.38 21.98 456 457 23.35 4.17 0.0 2.727 NC2 0.002 0.00 22.39 22.38 455 456 108.65 4.25 0.0 2.727 NC2 0.040 0.00 22.56 22.39 454 455 129.93 2.50 0.0 2.727 NC2 0.055 0.00 22.70 22.56 453 454 151.70 2.50 0.0 2.727 NC2 0.074 0.00 22.88 22.70 452 453 236.41 2.25 0.0 2.727 NC2 0.168 0.00 23.26 22.88 451 452 257.66 6.17 0.0 2.727 NC2 0.197 0.00 24.47 23.26 450 451 298.04 0.83 0.0 2.727 NC2 0.257 0.00 24.68 24.47 404 450 378.14 6.13 23.0 3.352 NC2 0.146 0.00 28.94 24.68 488 588 21.28 9.04 4.0 1.049 SG1 0.205 3.92 20.93 14.34 455 488 21.28 4.00 4.0 1.049 AOl 0.205 0.00 22.57 20.93 487 587 21.77 10.04 4.0 1.049 SG1 0.213 4.35 22.34 15.00 454 487 21.77 8.00 12.0 1.752 BN1 0.018 0.00 22.69 22.34 486 586 21.25 12.00 4.0 1.049 SG1 0.204 5.20 22.76 14.30 452 486 21.25 6.00 10.0 1.542 AO2 0.031 0.00 23.26 22.76 485 585 20.67 14.58 4.0 1.049 SG1 0.194 6.32 23.45 13.53 460 485 20.67 2.00 0.0 1.752 BN1 0.016 0.00 23.48 23.45 484 584 19.71 15.42 4.0 1.049 SG1 0.177 6.68 22.42 12.29 460 484 19.71 2.00 4.0 1.049 AOl 0.177 0.00 23.48 22.42 451 460 40.38 6.00 12.0 1.752 BN1 0.055 0.00 24.47 23.48 481 581 19.64 10.33 4.0 1.049 SG1 0.176 4.48 19.21 12.21 480 481 39.14 12.00 0.0 1.752 BN1 0.052 0.00 19.83 19.21 480 580 20.05 10.33 4.0 1.049 SG1 0.183 4.48 19.84 12.73 479 480 59.19 12.00 0.0 1.752 BN1 0.112 0.00 21.18 19.84 479 579 20.92 10.33 4.0 1.049 SG1 0.198 4.48 21.18 13.86 450 479 80.11 6.00 12.0 1.752.BN1, 0.195 0.00 24.70 21.18 AUXILIARY SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE R-305 DRY SYSTEM -UNUSED ATTIC .15 GPM / 1,950 SQ. FT. PER CITY OF TUKWILA. FILE NAME: R305DRYA FROM TO FLOW 06-23-1997 PAGE 4 LENGTH FITTING DIAM TYPE PSI/Ft S -LOSS PRESSURES 478 578 20.60 6.46 477 478 20.60 14.00 477 577 20.75 6.46 476 477 41.35 12.00 476 576 21.20 6.46 475 476 62.55 12.00 475 575 453 475 4.0 1.049 SG1 0.0 1.752 BN1 4.0 1.049 SG1 0.0 1.752 BN1 4.0 1.049 SG1 0.0 1.752 BN1 22.15 6.46 4.0 84.71 6.00 12.0 474 574 473 474 20.72 2.63 20.72 14.00 473 573 472 473 20.87 2.63 41.59 12.00 472 572 471 472 21.35 2.63 62.94 12.00 471 571 456 471 4.0 0.0 4.0 0.0 4.0 0.0 22.35 2.63 4.0 85.30 6.00 12.0 601 602 600 601 6 600 5 6 4 5 3 4 2 3 COMMENT: 1 2 COMMENT: 0 1 402.86 402.86 402.86 402.86 402.86 1.049 SG1 1.752 BN1 1.049 SG1 1.752 BN1 1.049 SG1 1.752 BN1 1.049 SG1 1.752 BN1 1.049 SG1 1.752 BN1 2.00 0.0 4.352 FR2 0.01 10.0 4.352 FR2 5.63 47.0 4.352 FR2 0.92 0.0 4.352 FR1 31.00 9.0 4.095 UN3 402.86 15.00 14.0 6.155 UN2 402.86 0.01 0.0 6.155 UN2 0.193 1.14 16.59 13.44 0.016 0.00 16.81 16.59 0.195 1.14 16.81 13.63 0.058 0.00 17.50 16.81 0.203 1.14 17.51 14.24 0.124 0.00 18.99 17.51 0.220 1.14 18.98 15.54 0.217 0.00 22.88 18.98 0.195 1.14 16.02 13.59 0.016 0.00 16.24 16.02 0.197 1.14 16.25 13.80 0.058 0.00 16.95 16.25 0.206 1.14 16.94 14.44 0.125 0.00 18.44 16.94 0.224 1.14 18.45 15.82 0.220 0.00 22.40 18.45 0.046 0.87 85.84 0.046 0.54 86.84 0.033 0.92 89.49 0.033 0.40 89.92 0.033 1.72 92.97 0.005 0.00 93.10 0.005 5.00 98.10 84.88 85.84 86.84 89.49 89.92 92.97 93.10 6" WILKINS 950 DA DCVA. 5 PSI LOSS AT 500 GPM OR LESS 402.86 5.00 47.0 6.155 UN2 0.005 0.00 98.34 98.10 250 GPM OUTSIDE HOSE ADDED AT HYDRANT CONNECTION. 652.86 305.00 116.0 8.265 UN1 0.003 0.00 99.48 98.34 SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East • Tacoma, Washington 98424 (206) 926-1880 • FAX (206) 926-2350 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME HOMESTEAD VILLAGE JOB NO. R 305 DATE 6/5197 ADDRESS 15635 WEST VALLEY HIGHWAY BY IPOMMERT TUKWILA, WASHINGTON SYSTEM DESIGNATION: WET -1ST FLOOR ( MOST DEMANDING) HAZARD DESCRIPTION: ORDINARY: GROUP 1 HAZARD CLASS PER NFPA 13 : HOTEL / MOTEL SPECIFIC RULING: ORDINARY HAZARD DENSITY -LIGHT HAZARD SPACING. RULING MADE BY: LT. KOHLER OF CITY OF TUKWILA DENSITY: .15 GPM OVER THE MOST HYDRAULICALLY REMOTE 1,500 SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: INSIDE HOSE 0 GPM OUTSIDE HOSE 250 GPM NODE 1, CONNECTION TO YARD MAIN. IN -RACK SPRINKLER DEMAND GPM SYSTEM TYPE: WET TOTAL NUMBER OF SPRINKLERS THIS SYSTEM 116 "C" FACTOR OVERHEAD : 120 "C" FACTOR UNDERGROUND : 140 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: 156 SQUARE FEET SPRINKLER MANUFACTURER: RELIABLE MODEL: F1 FR/F2 TEMPERATURE: K -FACTOR: 8.0 ORIFICE SIZE: 155"F 17/32" WATER SUPPLY: STATIC 147 PSI RESIDUAL 100 PSI FLOW 1,300 GPM ELEVATION OF TEST: SAME AS SITE. DATE OF TEST: DATA PROVIDED BY: CITY OF TUKWILA WATER DEPARTMENT LOCATION OF TEST: HYDRANT #114 AT STRANDER ST. & WEST VALLEY HIGHWAY. BASE OF RISER DEMAND 314.24 GPM REQUIRED AT 85.88 PSI (INCLUDING 0 GPM FOR HOSE STREAMS) SUMMARY 564.24 GPM REQUIRED AT 94.63 PSI AT CONNECTION TO CITY MAIN. (INCLUDING 250 GPM FOR TOTAL HOSE STREAMS) SHEET OF I1111111111111111111111111111t111l11181111111111111I111IIIIIII11111118 IIIIII81111u1111111 111111100111111111110111111111111100111.1111111 111 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■mmm■m■s■■m■■mmmmm■■mmmmmmmmmm ■■/■■■ ■ ■■m■■■sm■mm■■■mmmm■ I .■■■■■■■■■■■■■■■■■■■■■■■■■■■■■m■mm■■mmm■mmm■mm■mimismm■mmmm ■ ■mmm mm mm MOM ■■■■■■■■■■■■■■■■■■■■■■■■■m■m■m■smmmmmsmmm■I■m■mm■mm■mm■■mm■ 1 mm ■■■■m■mm■mmm■mm■mmm■■Ism■smsm$m■mmm■mmmm■m ■■■■■m■■■■■m■■■ m■ Immmmmmmmmm■■mm■■mmm. mmmsmmm■mmm■ml■mms■■mmmmm■■mm. mm■ ■ mm■mmm■m■mm■m■mmm m■■■m■m■■mm■mmmumm■mmm■■mmmm■■■.II■■■ 1■ !Ill ml ■ IIIIIII IIIIIIIIIIIIIIIII iiiiiiiiiiiiiiiiiiiiiii _ ummommummem iC ■■ ■■■= 8 _ u hili!!!ielii111iiiiiiiiiii=ii•IUSiiiiiliiiiiiiliimmii.M 1 2 a Ii mmiumiiiiiiiiiumm Iiminun � ■Imiiimiiii ■iiimiimi■m O c < 2 !iiiii■ii�■iiiiiii_iiilii�iiili'!iii■■iiiim■immmmimii■■ a. w W • in Q �� ■ ■ ■■ sme■ ■ ■■ _N d ■msi■ ■m ■■■mess■ ■ms ■■= N■ on mmmm■mmm■■■■■ mm U fcc - �iii'm■i i�iiimi i m mmiiliiii i !!iiiii\ i i miimmii Z W .} °C u) ��11�ill i1 Cid 1 i 80811111=CH 1 z N - U. �o W III■IIIii118i 1•11111111 ii '� i Millis + p ° Lu ii. w 0 71 ▪ in !OPPII"I'UI'P!W1 i illi =Iii ■ ip m r { U m g • u .C..1 C.....ILCC.0 �J ••CCi�C + a + Q ■■ i 1 I i ±- 1-- _.- pg =a ia$i.nolo,+ . u1 mil um Q a. 11111141111:11111141111 CC•CCC C ; "C�■.0 O =s. 0 iiuuiiii■■iiiu■!■C■W ili■■■i•CCCCUNCCiiiu:siini c u W m\•OEM ■ .■■■ ■l l- _1-� . -+ . i•:: ■■i■ mill■„=• p -7 - E CV • In a I - 7 l + _l} Y- ' t -' --, i \siiii ._ __ ■ W - o 0i- -+- - - -� ---� - - ■ J ■ U1 • -,-,4--.-t--T-} 1- 1 ■ ±. 1-� I LiIi1i" Z I-, -}- -r- EN III ! l.1- 1 tt+ nn11 Affair i Nrun11118n11nun118 IIn1 n IIn11nn 11n11m1I1nn111nn111 8 lInnnlnlnn IV In11 1INr111/ N®11 /nnlnlninll nl�nl N Immo n morin uuuu181u81 u X11m In IW NM n1n87uInn fl11n1111nnn111 I8► IIMEMn1n MILINI ■ i1n11111111111n111 1111111111 { 1111,1111111111111111111111111111111111 !VIII! 1 n 1 ll uIrr�IlhluuIl81 nll'IIUIIIlllnnw/Illulllllllllli11ni1 ClN1llllnl==n=liulni uill11111K 1111111111111111151111111111m.00111111111111111111111 1l ll�, lln=�l-iC lllln118n 11181 11 1=nnnln111811IIIIIIlnllnr,111n11lllnIIIIII11ll111111111111111 llllll■■llll■■llllllllulI lluluulfAulllllllllllllu'IllllllllllMGl■■hell!!!■■■■l■■■■u■■ llllll111111llulll ll llll 1luIB hull!!!/l■lllllrlll■lilt bell!■■!i!■■helm!■l■■■i■■ ��i�uueii�ieu�eiuli mumuormu eiie��i�B�m n� 1111i111i111111111ffi ill 1111111111111111111111111111111111111111111111111111,11:11. i►,®�111111111�1111�111111111 11111■■..■■■■�■■VA.■ ■■■■■■■■■■■■■■■■■■■■■■■ 111111111111111111111111 1111111111111111111111111111111 lid1flllllll111111lll Illlilflii II11I111111I111111118111111IIi1N1111I1111111!1111■111111 ■11111111Iu111I.I.I11I.I.II111I11111 ssss■■■iiii■■■iii■■iiisiiii■ri ssssssi■ iiiiiiii. ��� 11111111:111iiii1111i1111lii�illlii111ii 111illiriliiiiliiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii!!ii 1 IIII1IIIIIII1IIIIIIIIIIIIHiIIIIIIIIIHIIIOIIII1IIIIIHiIIIIIIIIIHOIIIIIIIiiiiiiiiiiiiIIh IUI111111II111111111i1111 I Ihi1111111 /18111111111111111111118111111111111111 111111111111111111111111//811111111111111111 11111I11111I11I81181II888111811!111111118118111 IIIIIi!!III!HHIHHIIIIIIHIII 111118IIIIIIIIICi!l11II!1IIIIIIIIAIIIIl1111! IIIIIIIIIIIIIIIIIii esssssississmissies■■Rs■ s■■ssssits■i■si■i■iiiisi\[aisss■s■ssisss■iassiss ■sississs■sssssi■is 1111111111111111111111741 181111111181■■m■■■■■isiit'_'llsill11111111111111111111111111111111111 iiillillliiiiiiiiiuiiGii-111lHllllilflifllllhill!■■■■■■ee■i■■:■*isiiii:lfl!lii111iiui111i11i !■sill■iis■iisiii■■�iissii■iisiifieiii issiiI ■■■■ilifis■i■sssiilsssiiilis si�_i!�■i■ ;U01•141.T4t1 ;W NIkiLI*4 CD a H Itrea MOWN IzI`I_ 7411 A R SUPPLY 9 LFA ..4 'ST FLO•t H AWitafflaW a_ a_ a 0 O O '1*-i1U1_11 O 0 M z 0 J LL :17,11 VII Xn u O O O O VO - N O - — - ISd NI 38f1SS31:Id O (D cssi X a z w J 0 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WASHINGTON. 1ST FLOOR. WET SYSTEM. .15 GPM / 1,500 SQ. FT. SMITH FIRE SYSTEMS, INC. 1106 54TH AVENUE EAST TACOMA, WASHINGTON. 98424 1-(253)-926-1880 FLOW TEST RESULTS Water Supply STATIC 147.00 PSI RESIDUAL 100.00 PSI @ 1300.00 GPM CITY PRESSURE AVAILABLE AT 564.2 GPM 136.97 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 178 20.57 15.08 5.70 13.03 179 21.30 15.08 5.70 13.97 180 21.51 15.08 5.70 14.24 181 22.29 15.08 5.70 15.29 189 27.21 26.81 8.00 11.57 190 26.81 26.81 8.00 11.23 191 27.11 26.81 8.00 11.48 192 28.44 26.81 8.00 12.63 194 19.19 18.00 5.62 11.66 195 19.34 18.00 5.62 11.84 196 19.83 17.48 5.62 12.45 197 20.81 17.48 5.62 13.71 198 20.66 18.00 5.62 13.51 199 19.19 18.00 5.62 11.65 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 1 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 102 TO 103 314.24 GPM 250.00 GPM 564.24 GPM 94.64 PSI 0.00 PSI 18.72 FPS 06-06-1997 PAGE 1 SUBMITTAL SERIAL NO:2244HY1 06-06-1997 PAGE 2 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WASHINGTON. 1ST FLOOR. WET SYSTEM. .15 GPM / 1,500 SQ. FT. Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 140 190 1.049 L 0.88 C=120 PT 11.23 (190) Q 26.81 F=T F 5.00 PE -0.38 DR T 5.88 0.2238 PF 1.32 PT 12.17 (140) 144 194 145 144 Q 19.19 Q 19.19 1.049 DR 1.542 BN2 L 0.88 C=120 PT 11.66 (194) F=T F 5.00 PE -0.38 T 5.88 0.1206 PF 0.71 L 10.00 C=120 PT 11.99 (144) F=0 F 0.00 PE 0.00 T 10.00 0.0185 PF 0.19 PT 12.18 (145) 145 195 1.049 L 0.88 C=120 PT 11.84 (195) Q 19.34 F=T F 5.00 PE -0.38 DR T 5.88 0.1222 PF 0.72 146 145DQ 19.19 1.542 L 9.71 C=120 PT 12.18 (145) Q 38.53 F=0 F 0.00 PE 0.00 BN2 T 9.71 0.0670 PF 0.65 PT 12.83 (146) 146 196 1.049 L 0.88 C=120 PT 12.45 (196) Q 19.83 F=T F 5.00 PE -0.38 DR T 5.88 0.1281 PF 0.75 106 146DQ 38.53 1.542 L 4.88 C=120 PT 12.82 (146) Q 58.36 F=T F 10.00 PE 0.00 BN2 T 14.88 0.1445 PF 2.15 PT 14.97 (106) 149 199 140 149 Q 19.19 Q 19.19 148 198 Q 20.66 1.049 DR 1.542 BN1 1.049 DR L 0.88 C=120 PT 11.65 (199) F=T F 5.00 PE -0.38 T 5.88 0.1205 PF 0.71 L 10.00 C=120 PT 11.98 (149) F=0 F 0.00 PE 0.00 T 10.00 0.0185 PF 0.19 PT 12.17 (140) L 0.88 C=120 PT 13.51 (198) F=T F 5.00 PE -0.38 T 5.88 0.1382 PF 0.81 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WASHINGTON. 1ST FLOOR. WET SYSTEM. .15 GPM / 1,500 SQ. FT. 06-06-1997 PAGE 3 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 147 148 1.542 L 9.71 C=120 PT 13.94 (148) Q 20.66 F=0 F 0.00 PE 0.00 BN1 T 9.71 0.0212 PF 0.21 PT 14.15 (147) 147 197 1.049 L 0.88 C=120 PT 13.71 (197) Q 20.81 F=T F 5.00 PE -0.38 DR T 5.88 0.1400 PF 0.82 106 147DQ 20.66 1.542 L 0.79 C=120 PT 14.15 (147) Q 41.46 F=T F 10.00 PE 0.00 BN1 T 10.79 0.0768 PF 0.83 170 106DQ 58.36 2.227 L 13.00 C=120 PT 14.98 (106) Q 99.82 F=0 F 0.00 PE 0.00 NC2 T 13.00 0.0651 PF 0.85 PT 15.83 (170) 142 192 1.049 L 0.88 C=120 PT 12.63 (192) Q 28.44 F=T F 5.00 PE -0.38 DR T 5.88 0.2495 PF 1.47 PT 13.72 (142) 141 191 1.049 L 0.88 C=120 PT 11.48 (191) Q 27.11 F=T F 5.00 PE -0.38 DR T 5.88 0.2284 PF 1.34 PT 12.44 (141) 139 189 1.049 L 0.88 C=120 PT 11.57 (189) Q 27.21 F=T F 5.00 PE -0.38 DR T 5.88 0.2300 PF 1.35 PT 12.54 (139) 134 179 1.049 L 4.71 C=120 PT 13.97 (179) Q 21.30 F=E F 2.00 PE -0.56 BN3 T 6.71 0.1463 PF 0.98 169 134 1.049 L 0.67 C=120 PT 14.39 (134) Q 21.30 F=T F 5.00 PE 0.00 BN3 T 5.67 0.1463 PF 0.83 PT 15.22 (169) 170 180 Q 21.51 1.049 L 5.42 C=120 PT 14.24 (180) F=T/2E F 9.00 PE -0.56 A01 T 14.42 0.1488 PF 2.15 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WASHINGTON. 1ST FLOOR. WET SYSTEM. .15 GPM / 1,500 SQ. FT. 06-06-1997 PAGE 4 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 132 170DQ 99.82 2.227 L 2.50 C=120 PT 15.83 (170) Q 121.33 F=0 F 0.00 PE 0.00 NC2 T 2.50 0.0935 PF 0.23 105 132 2.227 L 1.50 C=120 PT 16.06 (132) Q 121.33 F=0 F 0.00 PE 0.00 NC2 T 1.50 0.0935 PF 0.14 PT 16.20 (105) 171 181 1.049 L 5.42 C=120 PT 15.29 (181) Q 22.29 F=T/E F 7.00 PE -0.56 AOl T 12.42 0.1590 PF 1.97 FT 16.70 (171) 168 178 1.049 L 5.42 C=120 PT 13.03 (178) Q 20.57 F=T/E F 7.00 PE -0.56 AOl T 12.42 0.1371 PF 1.70 PT 14.17 (168) 103 104 2.727 L 66.50 C=120 PT 24.99 (104) Q 314.24 F=2E F 20.00 PE 0.00 NC1 T 86.50 0.2027 PF 17.53 PT 42.52 (103) 139 140 1.542 L 12.58 C=120 PT 12.17 (140) Q 24.89 F=0 F 0.00 PE 0.00 BL2 T 12.58 0.0299 PF 0.38 167 139DQ 27.21 1.542 L 2.04 C=120 PT 12.55 (139) Q 52.10 F=T F 10.00 PE 0.00 BL2 T 12.04 0.1172 PF 1.41 168 167 1.752 L 3.50 C=120 PT 13.96 (167) Q 52.10 F=0 F 0.00 PE 0.00 CM6 T 3.50 0.0629 PF 0.22 169 168DQ 20.57 1.752 L 9.00 C=120 PT 14.18 (168) Q 72.67 F=0 F 0.00 PE 0.00 CM6 T 9.00 0.1165 PF 1.05 135 169DQ -27.26 1.542 L 17.33 C=120 PT 15.23 (169) Q 45.41 F=T F 10.00 PE 0.00 BL2 T 27.33 0.0909 PF 2.48 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WASHINGTON. 1ST FLOOR. WET SYSTEM. .15 GPM / 1,500 SQ. FT. 06-06-1997 PAGE 5 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 136 135 1.542 L 7.17 C=120 PT 17.71 (135) Q 45.41 F=0 F 0.00 PE 0.00 BL2 T 7.17 0.0909 PF 0.65 137 136 1.542 L 18.00 C=120 PT 18.36 (136) Q 45.41 F=0 F 0.00 PE 0.00 BL2 T 18.00 0.0909 PF 1.64 138 137 1.542 L 7.17 C=120 PT 20.00 (137) Q 45.41 F=0 F 0.00 PE 0.00 BL2 T 7.17 0.0909 PF 0.65 152 138 1.542 L 17.33 C=120 PT 20.65 (138) Q 45.41 F=0/T F 10.00 PE 0.00 BL2 T 27.33 0.0909 PF 2.48 PT 23.13 (152) 141 140 1.542 L 12.58 C=120 PT 12.17 (140) Q 21.11 F=0 F 0.00 PE 0.00 BL2 T 12.58 0.0220 PF 0.28 142 141DQ 27.11 1.542 L 12.58 C=120 PT 12.45 (141) Q 48.22 F=0 F 0.00 PE 0.00 BL2 T 12.58 0.1015 PF 1.28 143 142DQ 28.44 1.542 L 12.58 C=120 PT 13.73 (142) Q 76.65 F=0 F 0.00 PE 0.00 BL2 T 12.58 0.2394 PF 3.01 153 143 1.542 L 14.63 C=120 PT 16.74 (143) Q 76.65 F=0/T F 10.00 PE 0.00 BL2 T 24.63 0.2394 PF 5.90 152 153 2.227 L 12.50 C=120 PT 22.64 (153) Q 76.65 F=0 F 0.00 PE 0.00 CM5 T 12.50 0.0400 PF 0.50 104 152DQ 45.41 2.227 L 5.67 C=120 PT 23.14 (152) Q 122.06 F=T F 14.00 PE 0.00 CM5 T 19.67 0.0945 PF 1.86 PT 25.00 (104) 105 169 1.752 L 5.67 C=120 PT 15.22 (169) Q 48.56 F=T F 12.00 PE 0.00 CM6 T 17.67 0.0552 PF 0.98 SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WASHINGTON. 1ST FLOOR. WET SYSTEM. .15 GPM / 1,500 SQ. FT. 06-06-1997 PAGE 6 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 171 105DQ -25.00 1.542 L 9.00 C=120 PT 16.20 (105) Q 23.57 F=0/T F 10.00 PE 0.00 BL2 T 19.00 0.0270 PF 0.51 151 171DQ 22.29 1.542 L 70.00 C=120 PT 16.71 (171) Q 45.86 F=T/E F 15.00 PE 0.00 BL2 T 85.00 0.0925 PF 7.86 104 151 2.227 L 12.50 C=120 PT 24.57 (151) Q 45.86 F=0/T F 14.00 PE 0.00 CM5 T 26.50 0.0154 PF 0.41 PT 24.98 (104) 102 103 2.227 L 4.50 C=120 PT 42.52 (103) Q 227.22 F=T/T F 28.00 PE 0.00 CM1 T 32.50 0.2983 PF 9.69 162 102DQ -150.12 2.227 L 5.67 C=120 PT 52.21 (102) Q 77.10 F=T F 14.00 PE 0.00 CM3 T 19.67 0.0404 PF 0.79 165 162DQ -37.55 1.542 L 67.00 C=120 PT 53.00 (162) Q 39.56 F=T/T F 20.00 PE 0.00 BL1 T 87.00 0.0704 PF 6.12 101 165DQ 37.55 1.752 L 5.67 C=120 PT 59.12 (165) Q 77.10 F=0/T F 12.00 PE 0.00 CM4 T 17.67 0.1299 PF 2.30 PT 61.42 (101) 163 162 2.227 L 12.50 C=120 PT 53.01 (162) Q 37.55 F=0 F 0.00 PE 0.00 CM3 T 12.50 0.0107 PF 0.13 164 163 1.542 L 67.00 C=120 PT 53.14 (163) Q 37.55 F=T/T F 20.00 PE 0.00 BL1 T 87.00 0.0639 PF 5.56 165 164 1.752 L 12.50 C=120 PT 58.70 (164) Q 37.55 F=0 F 0.00 PE 0.00 CM4 T 12.50 0.0343 PF 0.43 PT 59.13 (165) 161 103 2.227 L 8.00 C=120 PT 42.52 (103) Q 87.02 F=0/T F 14.00 PE 0.00 CM3 T 22.00 0.0505 PF 1.11 . SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WASHINGTON. 1ST FLOOR. WET SYSTEM. .15 Location Flow Pipe in Size From To GPM IN 101 161 1.752 Q 87.02 BL1 133 105 2.227 CM2 104 133 2.227 CM2 Q 146.32 Q 146.32 101 102 2.227 Q 150.12 CM1 100 101DQ 164.13 2.727 Q 314.24 FM1 6 100 4.352 FR1 4.352 FR1 4 5 4.095 Q 314.24 UN3 3 4 6.155 Q 314.24 UN2 Q 314.24 5 6 Q 314.24 2 3 COMMENT: 1 2 COMMENT: Q 314.24 GPM / 1,500 SQ. FT. Fittings Devices F=T/E,T F=0 F=0 F=0 F=T,GV,4E F=0 F=0 F=E Equiv Friction Length Loss Ft PSI/Ft 06-06-1997 PAGE 7 Pressure Summary PSI L 79.50 C=120 PT 43.63 (161) F 30.00 PE 0.00 T 109.50 0.1625 PF 17.79 PT 61.42 (101) L 16.50 C=120 PT 16.20 (105) L 0.00 PE 0.00 T 16.50 0.1322 PF 2.18 L 50.00 C=120 PT 18.38 (133) F 0.00 PE 0.00 T 50.00 0.1322 PF 6.61 PT 24.99 (104) L 66.50 C=120 PT 52.21 (102) F 0.00 PE 0.00 T 66.50 0.1386 PF 9.22 L 41.50 C=120 PT 61.43 (101) F 62.00 PE 3.02 T 103.50 0.2027 PF 20.98 L 1.62 C=120 PT 85.43 (100) F 0.00 PE 0.00 T 1.62 0.0208 PF 0.03 L 0.92 C=120 PT 85.46 ( 6) F 0.00 PE 0.40 T 0.92 0.0208 PF 0.02 L 31.00 C=140 PT 85.88 ( 5) F 9.00 PE 1.70 T 40.00 0.0210 PF 0.84 L F=EE,GV F T 15.00 C=140 PT 88.42 ( 4) 14.00 PE 0.00 29.00 0.0029 PF 0.08 6.155 L 0.01 C=140 PT 88.50 ( 3) F=T,GV F 47.00 PE 5.00 UN2 T 47.01 0.0029 PF 0.14 6" WILKINS 950 DA DCVA. 5 PSI LOSS AT 500 GPM OR LESS. Q 314.24 6.155 L 5.00 C=140 PT 93.64 ( 2) F=T,GV F 47.00 PE 0.00 UN2 T 52.00 0.0029 PF 0.15 250 GPM OUTSIDE HOSE ADDED AT HYDRANT CONNECTION. SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WASHINGTON. 1ST FLOOR. WET SYSTEM. .15 Location Flow in From To GPM Pipe Size IN 0 1DQ 250.00 8.265 Q 564.24 UN1 GPM / 1,500 SQ. FT. Fittings Devices L F=2T,2GV F T 06-06-1997 PAGE 8 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI 305.00 C=140 116.00 421.00 0.0020 PT PE PF 93.79 ( 1) 0.00 0.84 PT 94.63 ( 0) • 5F5 SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East • Tacoma, Washington 98424 (206) 926-1880 • FAX (206) 926-2350 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME HOMESTEAD VILLAGE JOB NO. R 305 DATE 6/5/97 ADDRESS 15635 WEST VALLEY HIGHWAY BY POMMERT TUKWILA, WASHINGTON SYSTEM DESIGNATION: WET -3RD FLOOR ( 2ND FLOOR TYPICAL) HAZARD DESCRIPTION: ORDINARY: GROUP 1 HAZARD CLASS PER NFPA 13 : HOTEL / MOTEL SPECIFIC RULING: ORDINARY HAZARD DENSITY -LIGHT HAZARD SPACING. RULING MADE BY: LT. KOHLER OF CITY OF TUKWILA DENSITY: .15 GPM OVER THE MOST HYDRAULICALLY REMOTE 1,500. SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: INSIDE HOSE 0 GPM OUTSIDE HOSE 250 GPM NODE 1, CONNECTION TO YARD MAIN. IN -RACK SPRINKLER DEMAND GPM SYSTEM TYPE: WET TOTAL NUMBER OF SPRINKLERS THIS SYSTEM 89(98) "C" FACTOR OVERHEAD : 120 "C" FACTOR UNDERGROUND : 140 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: 156 SQUARE FEET SPRINKLER MANUFACTURER: RELIABLE MODEL: F1FR/F2 TEMPERATURE: 155 ° F K -FACTOR: 8.0 ORIFICE SIZE: 17/32" WATER SUPPLY: STATIC 147 PSI RESIDUAL 100 PSI FLOW 1,300 GPM ELEVATION OF TEST: SAME AS SITE. DATE OF TEST: DATA PROVIDED BY: CITY OF TUKWILA WATER DEPARTMENT LOCATION OF TEST: HYDRANT #114 AT STRANDER ST. & WEST VALLEY HIGHWAY. BASE OF RISER DEMAND 290.83 GPM REQUIRED AT 66.31 PSI (INCLUDING 0 GPM FOR HOSE STREAMS) SUMMARY 540.83 GPM REQUIRED AT 74.74 PSI AT CONNECTION TO CITY MAIN. (INCLUDING 250 GPM FOR TOTAL HOSE STREAMS) RumabmileDrac !I•il►`ILMI4 ^ VALLEY HIGHWAY 'SECOND TYPICAL, aC 0 0 a w 2 F u1 H to cn w Z c o 0 a a a J�iIlL•I1 mmumarasumnium SHEET OF 4 - I1II1II1HIII 111111111111 ii :i I ..._........_......_ .._....... ■ . . .u.........■. .... .................. 11111Oi._..........r.. . ... •.• VI........ .. i::ii_ai.: . ...�...■.NUMMI -+NB ....... .... ■ Z wiii cnZ w - LL Z^ o - i 0 M O _ ` w V N CC i- ^ 0 O !- w m U -i-Q ( 1' Q 2 Z 2 a ▪ a Q) 0 0 0 N 1 in cn + c�1 O i ZI 0 `+ O /Acs in Y� N _ i 1.,_11 ` I 1 :: - .,��:_ I } _._, — — ' t -I--t i---i_i_ --I-i----•-:-.--_.-_ I(.--_---1-: -' - {1_ - �--1- - _ 1 r ------- __t_ I- -tlt-t i_ -t-i $ . . 11-11-11_1,-t- --.� - =_ ._ 4 rill- -141 r- (- I ! - I it --•- - +++---r -2411- i ` fl- - - •',-, 1 - = rt -, f-, .1' --I 1 --"!4- -.-1 I a i, _ t � rr .r 11-- aI r I!{ II + Iii 1 I 1t trr I i 1 1 1 1 ' I 47 ! !lit II! Hill i [1 U) w 0 J 0 z 11ZNIVID IIINWI IUum� mIU -iin�i1ii, uI►nuumiu111111111 ■ 11 1111 111111111111111111111111111 F O O O • O 0 VO 0 00 ISd NI 3af1SS3Fid 0 AUXILIARY SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WASHINGTON. 3RD FLOOR, WET SYSTEM. .15 GPM / 1,500 SQ. FT. SMITH FIRE SYSTEMS, INC. 1106 54TH AVENUE EAST TACOMA, WASHINGTON 98424 1-(253)-926-1880 FLOW TEST RESULTS Water Supply STATIC 147.00 PSI RESIDUAL 100.00 PSI @ 1300.00 GPM CITY PRESSURE AVAILABLE AT 540.8 GPM 137.72 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 378 23.33 14.87 379 23.28 14.87 380 23.33 14.87 381 23.56 14.87 382 25.06 14.87 386 27.41 26.81 387 26.81 26.81 388 19.01 15.61 389 18.45 15.61 390 19.50 15.61 391 18.92 15.61 392 21.40 15.61 393 20.77 15.61 5.62 17.23 5.62 17.16 5.62 17.24 5.62 17.58 5.62 19.89 8.00 11.74 8.00 11.23 5.62 11.44 5.62 10.77 5.62 12.04 5.62 11.33 5.62 14.50 5.62 13.66 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 1 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 353 TO 350 290.83 GPM 250.00 GPM 540.83 GPM 74.73 PSI 0.00 PSI 19.56 FPS 06-06-1997 PAGE 1 • AUXILIARY SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WASHINGTON. 3RD FLOOR, WET SYSTEM. .15 GPM / 1,500 SQ. FT. 06-06-1997 PAGE 2 FROM TO FLOW LENGTH FITTING DIAM TYPE PSI/Ft S -LOSS PRESSURES 347 387 26.81 0.63 5.0 1.049 A02 0.224 -0.27 12.22 11.23 346 386 27.41 0.63 5.0 1.049 A02 0.233 -0.27 12.78 11.74 342 382 25.06 0.63 5.0 1.049 A02 0.198 -0.27 20.73 19.89 341 381 23.56 0.63 5.0 1.049 A02 0.176 -0.27 18.30 17.58 340 380 23.33 0.63 5.0 1.049 A02 0.173 -0.27 17.94 17.24 339 379 23.28 0.63 5.0 1.049 A02 0.172 -0.27 17.86 17.16 338 378 23.33 0.63 5.0 1.049 A02 0.173 -0.27 17.93 17.23 350 393 20.77 8.21 7.0 1.049 A01 0.140 -0.27 15.51 13.66 350 392 21.40 1.71 7.0 1.049 A01 0.147 -0.27 15.51 14.50 349 391 18.92 8.21 7.0 1.049 AOl 0.117 -0.27 12.85 11.33 349 390 19.50 1.71 7.0 1.049 AOl 0.124 -0.27 12.85 12.04 348 389 18.45 8.21 7.0 1.049 A01 0.112 -0.27 12.20 10.77 348 388 19.01 1.71 7.0 1.049 AOl 0.119 -0.27 12.20 11.44 303 304 290.83 17.79 0.0 2.727 NC1 0.176 0.00 31.54 28.42 347 348 4.17 12.58 0.0 1.542 BL1 0.001 0.00 12.21 12.20 346 347 30.98 12.58 0.0 1.542 BL1 0.045 0.00 12.77 12.21 345 346 58.40 12.58 0.0 1.542 BL1 0.145 0.00 14.59 12.77 344 345 58.40 12.58 0.0 1.542 BL1 0.145 0.00 16.41 14.59 343 344 58.40 12.58 0.0 1.542 BL1 0.145 0.00 18.23 16.41 354 343 58.40 5.25 10.0 1.542 BL1 0.145 0.00 20.44 18.23 355 354 58.40 12.50 0.0 1.752 CM4 0.078 0.00 21.41 20.44 338 339 13.94 7.17 0.0 1.542 BL2 0.010 0.00 17.92 17.85 337 338 37.27 18.00 0.0 1.542 BL2 0.063 0.00 19.05 17.92 336 337 37.27 7.17 0.0 1.542 BL2 0.063 0.00 19.50 19.05 335 336 37.27 18.00 0.0 1.542 BL2 0.063 0.00 20.63 19.50 355 335 37.27 2.25 10.0 1.542 BL2 0.063 0.00 21.40 20.63 305 355 95.66 5.67 12.0 1.752 CM4 0.194 0.00 24.82 21.40 356 305 22.51 12.50 12.0 1.752 CM4 0.013 0.00 25.15 24.82 351 356 22.51 98.00 20.0 1.542 BL1 0.025 0.00 28.08 25.15 304 351 22.51 12.50 12.0 1.752 CM3 0.013 0.00 28.41 28.08 349 348 33.28 12.58 0.0 1.542 BL1 0.051 0.00 12.84 12.20 AUXILIARY SUBMITTAL SERIAL NO:2244HY1 HOMESTEAD VILLAGE 15635 WEST VALLEY HIGHWAY TUKWILA, WASHINGTON. 3RD FLOOR, WET SYSTEM. .15 GPM / 1,500 SQ. FT. FROM TO FLOW LENGTH FITTING DIAM TYPE 350 349 71.70 12.58 0.0 1.542 BL1 353 350 113.87 4.96 10.0 1.542 BL1 352 353 113.87 12.50 0.0 2.227 CM3 340 339 9.34 18.00 0.0 341 340 32.67 7.17 0.0 342 341 56.24 18.00 0.0 352 342 81.30 2.25 10.0 304 352 195.17 5.67 14.0 362 303 87.03 5.67 14.0 363 362 42.58 12.50 0.0 364 363 42.58 86.08 20.0 365 364 42.58 12.50 0.0 365 362 44.45 86.08 20.0 301 365 87.03 5.67 12.0 361 303 47.61 12.50 12.0 366 361 47.61 86.08 20.0 301 366 47.61 12.50 12.0 330 305 73.15 2.25 0.0 331 330 73.15 18.00 0.0 332 331 73.15 7.17 0.0 333 332 73.15 18.00 0.0 334 333 73.15 7.17 0.0 304 334 73.15 45.12 0.0 301 303 156.19 88.08 0.0 300 301 290.83 34.42 35.0 100 300 290.83 28.50 58.0 6 100 290.83 0.54 0.0 5 6 290.83 0.92 0.0 4 5 290.83 31.00 9.0 3 4 290.83 15.00 14.0 2 3 290.83 0.01 0.0 1 2 290.83 5.00 47.0 0 1 540.83 305.00 116.0 1.542 BL2 1.542 BL2 1.542 BL2 1.542 BL2 2.227 CM3 2.227 CM5 2.227 CM5 1.542 BL1 1.752 CM6 1.542 BL2 1.752 CM6 1.752 CM5 1.542 BL1 1.752 CM6 2.227 CM2 2.227 CM2 2.227 CM2 2.227 CM2 2.227 CM2 2.227 CM2 2.227 CM1 3.352 FM1 3.352 FR2 4.352 FR1 4.352 FR1 4.095 UN3 6.155 UN2 6.155 UN2 6.155 UN2 8.265 UN1 06-06-1997 PAGE 3 PSI/Ft S -LOSS PRESSURES 0.212 0.00 15.50 12.84 0.498 0.00 22.95 15.50 0.083 0.00 23.99 22.95 0.005 0.049 0.135 0.267 0.225 0.051 0.014 0.081 0.043 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 O .00 17.94 18.29 20.72 23.99 28.42 32.54 32.71 41.27 41.81 17.85 17.94 18.29 20.72 23.99 31.55 32.54 32.71 41.27 0.087 0.00 41.81 32.54 0.163 0.00 44.68 41.81 0.053 0.00 0.099 0.00 0.053 0.00 0.037 0.037 0.037 0.037 0.037 0.037 0.149 0.064 0.064 0.018 0.018 0.018 0.002 0.002 0.002 0.002 0.00 O .00 0.00 0.00 O .00 O .00 0.00 0.00 11.18 0.00 0.40 1.70 0.00 5.00 0.00 0.00 32.86 43.38 44.69 24.92 25.58 25.84 26.50 26.76 28.41 44.68 49.14 65.88 65.89 66.31 68.74 68.81 73.81 73.94 74.74 31.55 32.86 43.38 24.84 24.92 25.58 25.84 26.50 26.76 31.55 44.68 49.14 65.88 65.89 66.31 68.74 68.81 73.81 73.94 El LOW -PROFILE 0 DrntrT-WrnE SMOKE DETECTOR O '71 FEATURES: • 12/24 VDC operation • • Visual alarm, power, and maintenance indicator ■ • 2- and 4 -wire models available • • Same housing design for both ion and photo models • Built-in test switch Plug-in terminal block for easy installation and maintenance Thermal models available Field sensitivity metering of detector to meet the requirements of NFPA 72 3 -year warranty System Sensor's 100 SeriesTM low -profile, direct -wire detectors pack superb performance and reliability into a small package. Their sleek, 1.66" (43 mm) profile is the lowest in the industry, making 100 Series devices the detectors of choice in applications where aesthetics are important. Other key features include: low current draw, stable performance in high air velocities, built-in tamper-resistant base design, removable cover and insect screen. MADE IN THE U.S.A. SYSTEMSENSOR'= A DIVISION OF P/TTWAY 3825 Ohio Avenue, St. Charles, IL 60174, 1-800-SENSOR2 (736-7672), Fax 708-377-6495 An ISO 9001 Certified Company GENERAL DESCRIPTION System Sensor 100 SeriesTM low profile detectors use state-of-the-art sensing chambers to meet all applicable UL performance criteria. The backs of the smoke detectors are sealed against back pressure, air flow. and dirt. A fine mesh screen also protects the chamber against the entry of insects. These detectors are intended for open area protection and for use with UL -listed control panels. Ionization All 100 Series ionization smoke detectors use a single source. dual chamber design for the detection of smoke particles. This extremely stable chamber significantly reduces nuisance alarms and provides reliable performance at higher air velocities. Photoelectronic The unique design of the optical sensing chamber in 100 Series photoelectronic smoke detectors can sense smoke particles from a wide range of combustion sources. These detectors minimize nuisance alarms by using a custom integrated circuit for signal processing. SPECIFICATIONS Operating Voltage: Relay Contact Rating (4 -wire only): Standby Current: Alarm Current 2 -wire: 4 -wire: Temperature Range: Thermal Models: INITIATING LOOP ULUSTED OMPATIBL CONTROL PANEL 12 or 24 VDC (nominal) 1 Form A, 1A @ 30 VDC 50 µA maximum average 100 mA maximum, limited by panel 65 mA maximum 32° to 120°F (0° to 50°C) 32° to 100°F (0° to 39°C) RAA00Z REMOTE ANNUNCIATOR RA400Z REMOTE ANNUNCIATOR �a °r�cnine OPTIONAL CLASS A WIRING Dimensions Diameter: Height: Weight: Humidity Range: Spacing: POWER TO DETECTORS UL LISTED CONTROL PANEL INITIATING LOOP 5.5 inches (140 mm) 1.66 inches (43 mm) including adapter bracket 5.3 oz. (150 grams) 10% to 93% RH, noncondensing On smooth ceilings (as defined in NFPA 72). spacing of 30 feet (900 sq. ft.) may be used as a guideline. Other spacing may be used depending on ceiling height, high air movements, and other conditions or response requirements. LB ' w\ R e0 EOL SUPERVISION `-+a+'•--`� RELAY (SHOWN ENERGIZED) A77.7168 EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER OPTIONAL CLASS A WIRING ■ Wiring Diagram for 1100, 2100, 2100T E Wiring Diagram for 1112/24, 2112/24, 2112/24T ORDERING INFORMATION Part No. Description 1100 Ion, 2 -Wire, 12/24 VDC 1112/24 Ion, 4 -wire, 12/24 VDC 2100 Photo, 2 -Wire, 12/24 VDC 2100T Photo with 135°F thermal, 2 -wire, 12/24 VDC 2112/24 Photo, 4 -Wire, 12/24 VDC Part No. 2112/24T A77 -716B MOD400R Description Photo with 135°F thermal, 4 -wire, 12/24 VDC EOL Power Supervision Relay Module, 12/24 VDC Sensitivity Test Tool for 100, 200, 300, 400, and 500 Series Smoke Detectors SYSTEM SENSOR WORLDWIDE MANUFACTURING & DISTRIBUTION In the Far East: System Sensor Far East Sales Office Pittway Far East LTD Suite 706, World Shipping Centre 7 Canton Road Tsimshatsui, Kowloon. Hong Kong Telephone: 852-730-9090 FAX: 852-736-6580 This document is not intended to be used for installation purposes A05-227-00 Corporate Headquarters: System Sensor 3825 Ohio Avenue St. Charles. IL 60174, USA Telephone: 708-377-6580 FAX: 708-377-6495 © System Sensor 8/94 In the United Kingdom: System Sensor Limited Horsham Gates III, North Horsham, West Sussex RH13 511. United Kingdom Telephone: 44 403 276500 FAX: 44 403 276501 In Italy: System Sensor Pittway Tecnologica, S.p.A. Via Caboto. 19 34147 Trieste, Italy Telephone: 39 40 381887 FAX: 39 40 382137 • Edwards® 2806 Series Heat Detector • RATE -OF -RISE AND FIXED TEMPERATURE s USE FOR PROPERTY PROTECTION ONLY • FM (FACTORY MUTUAL) APPROVED • UL LISTED FEATURES • WHITE—blend with ceiling. • LOW PROF!LE—with wide base covering mounting plate and box. • POSI- TIVE OPERATING INDICATION—when fixed tem- perature element is activated, center disc falls free from detector. (Detector replacement is required) •ON SITE TESTING—rate-of-rise feature is automatically self - restoring permitting on site testing of this feature. • EASY INSTALLATION—twist and it locks in place: same mounting plate for 31/2 or 4 inch octagon box, or open mounting. Terminals clearly marked. • WIDE SPACING -50 foot centers on rate -of -rise and fixed temperature units. (See Specification Table for details) DESCRIPTION Heat Detectors are available with 135 or 194 degree Fahrenheit ratings: in fixed, or fixed and rate -of -rise temperature operation with single circuit normally open contacts. The Heat Detector is available with either a metal or white plastic reversible mounting plate, (See Note '1). Both the metal plate (see below) and plastic plate (See page E24) can be used for either flush or surface mounting. Skirt — Cat. No. 6253 Decorative enclose to cover electrical box when surface mounting the 280B -PL (See Note •1) series Detector. For use with standard 31/2" or 4" octagon boxes. 11/2" deep. See page E24. Contact ratings on all models are 3 amps @ 6 to 125 VAC, 1.0 amps @6to28VDC, 0.3amps(@125VDC, and .01 amps @ 250 VDC. CalNo.* 2818 2828 283B 2848 Number of Circuits Normal Cond. ol Contacts Rate -of -Rise (Nota 4) or Fixed Temp. U.L. Temp. Ruling °F U.L. Max. Ambient Calling Tamp. Raring °F Maximum Cover ga Wale 2) Max. Distance from Wall Sq. FL Spacing (Nine 3) Open ROA & Fixed 135 100 Open ROR & Fixed 194 150 Open Fixed 135 100 Open Fixed 194 150 2500 50' 25' NOTES '1. For white plastic reversible mounting plate in place of standard metal plate. add suffix .-PL" to Cat. No. fe.g. 2818•PL). 2 Maximum delectoi coverage has been determined by UL to provide detection time equal t0 sprinkler devices spaced at 10 -tool intervals MG square toot areal on a smooth ceiling 15 feet 9 inches high. Higher ceilings can adversely affect detection time in some instances. earlier detection may be obtained by reducing the spacing between detectors. Seo Appendix C. Guido for Automatic Detector Spacing. NFPA 72E..1987. Automatic Fire Detectors. 3. Maximum distance shown is from any wall partition or ceiling projection extending down more than 12 inches. 4 Rate -of -Rise rating is t5^FIMin-Self-Reslormg. WARNING 1. DANGER- This device does not protect life against fire and smoke. In most fires, hazardous levels of smoke, heat and toxic gases can build up before a heat detector would initiate an alarm. Independent studies Indicate that heat detectors should only be used when property protection alone is Involved. In cases where life safely is a factor, the use of smoke detectors Is recommended. The Intended use o1 the Edwards 2808 Series Heat Detector is to provide one source of information that Is supplemental to smoke detection to increase the probability that an early warning will be provided so that property can be safeguarded. Heat detectors do not always detect fires because the fire may be a slow smoldering, low heat type (producing smoke) or because they may not be near where the fire occurs, or because the heat of the fire may bypass them. This detector will not detect oxygen levels, smoke, toxic gases, or flames. Accordingly, this device should only be used as a part of a broadly based program of fire safety which would include a variety of sources of information on heat and smoke levels, visual sighting bf the fire, extinguishment systems, and other safely measures. If they are spaced in accordance with the above table, they can contribute, within an overall fire safety program, to reducing the risk of avoidable property losses. Under no circumstances should these devices be relied on as the sole measure to ensure fire safety. Danger will result If these devices are relied on to any degree for the protection of human life. 2. DANGER - This device does not contain a built -In signal. Alarm signals can only be generated by interconnection with separately installed signaling devices. 3. DANGER - This device will not operate without electrical power, and fires often cause cutoffs of electrical power. This device does not contain a battery backup power supply. 11 the electrical circuit feeding the device Is cut, or Is not providing power for any reason, this device will not detect heat or provide any warning of a possible fire. Nor will it provide any warning that It Is not functioning. 4. DANGER - The rate -of -rise feature on the Edwards 2808 Series Heat Detector Is subject to failure over time. The rate - of -rise feature should be tested by a qualified fire protection specialist annually to ensure that it Is In working order. NOTE: Dimensions are in inches and (millimeters). Specifications subject to change without notice. BG-1OLX Addressable Manual Pull Station GENERAL The BG-10LX is an addressable manual pull station with a key -lock reset feature. It provides the MS -9200 with one addressable alarm initiating input. FEATURES • Highly visible. • Easily operated (Dual -Action). • Attractive shape and textured finish. • Semi -flush, mounts to a standard single -gang (2.125" min. depth), double -gang, or 4" square electrical box. • Operates with or without a crush tube. • Handle latches in the down position to clearly indicate the station has been operated. • Key reset. • Screw terminals for easy connection to SLC Loop Chan- nel. • Optional trim ring. CONSTRUCTION • Shell, door, and handle are molded of durable LEXAN® with a textured finish. • 16 gauge steel back plate. OPERATION Pulling the handle down causes it to latch in the down position. The handle is restored manually by using a me- chanical key which allows the top of the case to pivot forward and the spring-loaded handle to return to its normal position. The case can then be pivoted back to its normal position and secured with the key. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. A pair of rotary decimal switches allows two digit address -setting. PRODUCT LINE INFORMATION Model Description BG -TR Optional trim ring. 6 1/2" High, 5 1/8" Wide, 5/32" Deep. SB -10 Surface back box. Fire-LITe Alarms incorPoraTeo 12 Clintonville Road Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 S711 California State Fire Marshal 7150-0075:103 The BG-10LX Addressable Manual Pull Station ISO -9001 Engineering and Manufacturing Quality System Certified to International Standard ISO -9001 wwrrw ower... OF -51366 Page 1 of 2 July 6, 1994 INSTALLATION The BG-10LX will mount semi -flush into a single -gang, double - gang. or standard 4" square electrical outlet box, or will surface mount into the Model SB -10 surface backbox. If the BG-10LX'is being semi -flush mounted, then the optional trim ring (TR-BG10) may be used. The TR-BG10 is usually needed for semi -flush mount with 4" or double -gang boxes (not with single -gang boxes). ELECTRICAL SPECIFICATIONS Normal operating voltage 24 VDC Maximum SLC Loop voltage 28.0 VDC Maximum SLC Loop current 230 pA. ARCHITECTURAL/ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be addressable, fiber break -tube (or non -fiber break -tube) type, equipment with a key operated test - reset lock in order that they may be tested, and so designed that after emergency operation, they cannot be restored to normal except by using a key. An operated station shall automatically condition itself so as to be visually detected, as operated, at a minimum distance of one hundred feet, front or side. Manual Stations shall connect with two wires to one of the control panel SLC loops. The Manual Station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide two digit address - setting by use of rotary decimal switches. Manual Stations shall be constructed of LEXAN® with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in raised letters, 1.75 inches or larger. Stations shall be suitable for surface mounting on matching back -box, or semi -flush mounting on a standard single - gang, double -gang box, or 4 inch square box, and shall be installed not less than 4.5 feet, nor more than 6 feet, above the finished floor. Manual Stations shall be Underwriters Laboratories Inc. Listed. Lexan is a registered trade mark of General Electric. 8-3/16" 4-1/2" 0 0 0 0 0 0 �� 0 O O SBA -I0 1-3/8" Deep 4-1/8" O 0 ' 0 0 -- 0 O SB -10 The BG-10LX (back view) 3 0 m 0 5, to 0 CD Top View 4-1/8" Optional surface back -box. Side View We try to keep our product information up-to-date and accurate. We cannot cover specific applications or anticipate alll OF -51366 requirements All specifications are subject to change without notice For more Information contact FIfetlT@ ratle el e� III B • B -011111', • tK Y itm V o r9pn kDR e ( e • The SLC MO l-) l+) Loop fib Channel Ili 1 The BG-10LX (back view) 3 0 m 0 5, to 0 CD Top View 4-1/8" Optional surface back -box. Side View We try to keep our product information up-to-date and accurate. We cannot cover specific applications or anticipate alll OF -51366 requirements All specifications are subject to change without notice For more Information contact FIfetlT@ InteiliKnight Model 5820 Analog/ Addressable Fire Alarm Control System FILE The IntelliKnight system is the smart way to make the most of fire alarm technology. The IntelliKnight system is the first fire alarm system to provide you with the revolutionary value and performance of analog, addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as detector sensitivity, day/night thresholds, drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 612-493-6435. Description The IntelliKnight system uses analog data from the sensors installed on the signalling line circuits (SLC) to set sensitivity levels for each of the zones in the system. In addition, the Model 5820 uses the analog data to perform drift compensation and sensitivity checks on each of the sensors in the system. The IntelliKnight Model 5820 can be expanded by adding modules such as the Model 5860 Remote Annunciator, Model 5815 Signalling Line Circuit (SLC) Expander, Model 5824 Printer Interface and the Model 5880 Status Display Driver on the built-in RS -485 communication bus. The Model 5820 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. FEATURES • Up to 381 analog addressable points. • Distributed, intelligent power. • Sensor sensitivity settings. • Day/night sensitivity setting. • Drift compensation. • FlexputTM I/O circuit. • ANSI cadence pattern. • Built-in annunciator with 80 -character LCD display. • RS -485 bus provides communica- tion to system accessories. • Built-in RS -232 interface for programming via PC. • Built-in digital communicator. • Form C trouble relay rated at 2.5 amps at 24 VDC. • Two Form C programmable relays rated at 2.5 amps at 24VDC. • Uses standard wire — no shielded or twisted pair required. Model 5820 N. \'`k SILENT KNIGHT E—A LARM"ACC ESS"O-R1' Intellil(night Model 5820 Analog Addressable Eire Alarm Control Panel System Application The IntelliKnight Model 5820 control panel has one built-in Signalling Line Circuit (SLC) which supports 127 devices. Two additional loops can be added using the 5815 SLC expanders to increase overall capacity to 381 devices. The Model 5820's SLC loops support multiple device types: • Analog addressable photoelectric sensor • Analog addressable ionization sensor • Analog addressable heat sensor • Fast response contact module • Relay output module • Audio output module The following advanced analog sensor capabilities are available using the IntelliKnight Model 5820: • Sensitivity adjustment • Automatic drift compensation • Maintenance alert • Built-in sensor test to comply with NFPA 72 calibration testing requirements • Day/night sensitivity adjustment The Model 5820 features a 6 amp power supply. The IntelliKnight system features maximum battery charging capacity of 34 amp/hours. An additional cabinet enclosure is required for batteries in excess of 17 amp/hours. FlexputTM circuits on the Model 5820 control can be individually programmed to function as notification circuits or auxiliary power outputs. The IntelliKnight system operates on non - twisted, unshielded cable when wired in compliance with standard wiring practices as called out in the National Electric Code 760 specifications for power limited fire protective signalling cables. No special wiring is required. The Model 5820 provides seven preset notification cadence patterns including ANSI 3.41 and four user programmable selections for fire alarm notification. Two programmable general purpose Form C relay outputs are provided on the Model 5820 FACP. Additionally, the IntelliKnight system features a built-in walk test and auto - programming. Its innovative, dead -front cabinet design has been designed for flush or surface mounting. System maintenance is easy to perform. Built -In Digital Communicator The IntelliKnight Model 5820 features a built-in UL listed digital communicator for remote reporting of system activity and system programming. The communicator has the ability to seize two telephone lines to report alarms and troubles to a monitoring facility. The communicator supervises two phone lines and will activate a trouble signal if a line failure is sustained for more than 45 seconds. Other communication features include: re -try if communication fails, two phone number capability, download phone number capability and touchtone or rotary dialing. The communicator is compatible with SIA, Ademco Contact ID. The format is selectable by account number. User Interface The IntelliKnight's built-in annunciator with 80 character LCD display and large easy- to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's event history buffer stores 500 events for viewing from the built-in or remote annunciator (or using the RS -232 interface and a PC). System operation can be initiated with a mechanical fire fighter's key or a valid 4- to 7 -digit operators code. IntelliKnight Model 5820 Analog Addressable Fire Alarm Control Panel Up to eight additional Model 5860 Remote Annunciators can be used with the IntelliKnight Model 5820. These attractive units also feature an 80 character LCD display and a key- or code -activated touchpad. The remote annunciator provides the same system operation as the built-in annunciator. Programming The IntelliKnight system's autostart feature minimizes programming required to start a new system. The IntelliKnight system may be programmed locally through the built-in panel keypad or through the Model 5860 Remote Annunciator, or remotely using the WindowsTM based software. OPTIONAL ACCESSORIES: 5815 Signal Line Circuit Expander The SLC expander is used to add more analog addressable devices to the IntelliKnight system. Each 5815 can support 127 devices and interfaces to the 5820 via the RS -485 system bus. IntelliKnight can support two 5815s. ALARM ACCESSO Powerful IntelliKnight accessories provide unmatched flexibility. SPECIFICATIONS Electrical Specifications Primary AC: 120 VRMS at 60 hz, 2.5A Total Accessory Load: 4A at 24 VDC 5820 Power Supply 6 amps at 24 VDC of power limited notification power FlexputTM Circuits Six programmable circuits which can be programmed individually as: Notification circuits: 3 amps of power limited power per circuit at 24 VDC. Auxiliary power circuits: 3 amps of power limited power per circuit at 24 VDC. *Note: FlexputTM circuits can be configured as class "B" or they can be paired to make a class 'A circuit. INDICATOR LIGHTS: GENERAL ALARM (Red) - On for alarm SUPERVISORY (Yellow) - On when a supervisory condition exists. SYSTEM TROUBLE (Yellow) - On when a trouble condition exists. SYSTEM SILENCED (Yellow) - On when an alarm, trouble or supervisory condition has been silenced but not yet cleared. SYSTEM POWER (Green) - On when power systems are normal; flashes for AC or DC failure. MECHANICAL SPECIFICATIONS: Dimensions: 16 in. W x 26.4 in. H x 4.65 in. D (40.6 cm W x 67 cm H x 11.8 cm D) Weight: 28 lbs. (12.8 kg.) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31 X (two required) APPROVALS: UL Listing NFPA 72 -Central Station -Local Protective Signalling Systems -Remote Signalling F1"E ALARM ACCESSORY Inteiliknight Systems Accessories 5860 Remote Fire Annunciator The 5860 features the same 80 character backlit LCD display keypad and firefighters' keyswitch as the 5820. The IntelliKnight system can be fully programmed and operated from any 5860 remote fire annunciator. The 5860 connects to the 5820 via the RS -485 system bus. The Model 5820 FACP can support up to eight 5860s. Analog Modules IntelliKnight's analog modules, including photoelectric, ionization smoke detectors, and heat detectors feature a low profile design and EEprom addressing. EEprom addressing prevents water intrusion problems via the back of the sensor and eliminates mechanical failures related to DIP and decade switches. Model SD505-APS Analog addressable photoelectric smoke detector. SILENT KNIGHT Model SD505-AIS Analog addressable ionization smoke detector. Model SD505-AHS Analog addressable heat sensor. Model SD505-6AB 6 inch base designed for use with detector head models SD505-APS, SD505-AIS and SD505-AHS. Model SD505-CM Dry Contact Input Module. Designed to mount on a 4 inch square electrical box. It features an indicator LED to show alarm status and a coverplate. Model SD505-MCM Mini Dry Contact Input Module. A miniature version of the contact input module which is designed to be used with pull stations and other dry contact inputs where a smaller size is desired. 7550 Meridian Circle, Maple Grove, MN 55369-4927 1-800-446-6444 or in Minnesota 6U-493-6435 FAX: 1-800-311-1715 Model SD505-R2M Output Module Features 2 single pole output relays, designed to mount on a 4 inch square electrical box. Provides indicator LED to show output status and comes with a coverplate. Model SD505-AOM Output Module Used to control notification appliances and voice evacuation circuits. Designed to mount on a 4 inch square electrical box and features an indicator LED to show output status and comes with a coverplate. Model SD505-SAK Addressable pull station designed to be used with the IntelliKnight system. Mounts on a 4 inch square electrical box with single gang mud ring. MADE IN AMERICA FORM #150761, 7/96 c INTELLIKNIGHT ACCESSORY Model 5860 Remote Annunciator Bring the power to control IntelliKnight to ✓ every area within your facility. vm Now you can operate and program your IntelliKnight system from up to 8 locations throughout your facility. The Model 5860 Remote Annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80 - character display and ergonomically designed keypad allow for simple and error -free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS -485 system bus. Depending on wiring methods used, wire runs can be up to 6000 feet from the panel. Model 5860 Remote Annunciator The 5860 is designed to look and operate exactly the same as the built- in annunciator. Features include an 80 -character backlit LCD providing easy -to -understand system messages. The annunciator is ergonomically designed with over -sized buttons for the most frequently used features, Reset and Silence. In addition to status messages displayed on the LCD, five LEDs for alarm, supervisory, trouble, silence, and AC power indicate status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush - mounted. A trim ring kit is available for surface mounting. Operation When the system is normal and receiving AC power, the Power LED is lit and all other LEDs are off. Other LEDs turn on as the conditions occur. Users identify themselves to the control panel by entering a code on the annunciator or by turning the firefighter's key. When a user presses a button, the annunciator piezo beeps and the LCD prompts the user to enter a code or other relevant information. Multiple users can work at different annunciators simultaneously without affecting each other. Features • 80 -character display • Tactile / audible feedback • Accepts user codes or firefighter's key. • RS -485 interface to panel • Can be flush- or surface - mounted. Trim ring available for surface -mounting. • Operation and appearance identical to on -board annunciator • Supports simultaneous use by multiple users • UL Listed, complies with NFPA 72 SILENT KNIGHT 5860 Remote Annunciator Specifications Operating Voltage: 24 VDC Standby Current: Alarm Current: 20 mA 25 mA Max. per system 8 Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: Surface or flush Wiring distance from IntelliKnight panel Up to 6,000 feet (depending on wiring method) Dimensions: Height: 7-3/8" Width: 9-1/8" Depth: 1-1/2" Colors: Lt. gray (5860) Red (5860R) INTELLIKNIGHT ACCESSORY Model 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80 character LCD display and must feature five LEDs for: General Alarm; Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciators must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. 5860 BLOCK DIAGRAM Intell!Knight Hanel SILENT KNIGHT Up to 6000 feet from panel (depends on wiring method used). 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com Model 5860 0 0 o <©i> CD o 0 0 0 Up to 8 devices per system. MADE IN AMERICA FORM# 350320, Rev. 4/97 Copyright © 1997 Silent Knight Security Systems Firepower 5395 Distributed Power Module In an emergency, you need maximum power. ilk The Firepower 5395 Distributed Power Module by Silent VILk Knight is the most -powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance ' circuit power — what you need to drive power-hungry components like ADA notification appliances. The 5395's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with Firepower 5395 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need Firepower 5395. Call Silent Knight today for more information, 1-800-446-6444. Firepower 5395 Distributed Power Module The Firepower 5395 is a notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5207 Fire Control/ Communicator. The 5395 is the cost-effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). With 6 amps of notification power, Firepower 5395 drives the additional sounders and brighter strobes required. Meeting ADA requirements is easily accomplished in a retrofit or new installation. Features • UL Listed for 6 amps of notification power. • Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems. • Integrates with existing systems for simple, cost-effective ADA retrofits. • Dip switches allow for easy reconfiguration. • 24VDC regulated output voltage. • Four power -limited notification outputs; 2 Class A or 4 Class B, ort Class A and 2 Class B. • Additional continuous auxiliary output. • Three amps per output circuit. • Two inputs; 2 Class B or 2 Class A. • Ground fault detector/indicator. • Independent trouble relay. • AC loss delay option shuts off power to non-essential high -current acces- sories like magnetic door holders. • Stand alone operation. • Lightweight design adds to ease of installation and reduces shipping costs. • Operates with most polarized, UL -Listed notification devices. • UL864 & 1481 listed. Connection to Local Fire Control Firepower 5395 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on Firepower 5395. The control panel's notification circuit end -of -line resistor is also connected across two terminals on Firepower 5395, which provides supervision between Firepower 5395 and fire control panel. Polarized audible and/or visual notification devices are then connected to Firepower 5395 signal circuits using the 4.7K ohm end -of -line resistors provided. Since Firepower 5395 draws very little power 9LENT I NIGIT MODEL 5395 DISTR. TED POWER MODULE Firepower 5395 Distributed Power Module from the local control, it is possible to connect one Firepower 5395 to each notification circuit on the control panel and stilt/ provide full supervision of the notification circuits all the way back to the control panel. SILENT KNIGHT Firepower 5395 Distributed Power Module Supervision Firepower 5395 supervises a variety of functions including: • Low AC power. • Low battery condition. • Earth ground fault. • Auxiliary output power limit condition. • EOL supervision trouble or power limited condition at an output. When a trouble condition occurs, Firepower 5395 creates a trouble con- dition on the host control signal circuits to which it is connected. Firepower 5395 still maintains the ability to be activated by the host control. In addition, the 5395 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. Specifications Electrical AC Input: 120VAC at 2 amps Output: Auxiliary power circuit: Notification circuits: Output configuration: Amps per output circuit: Notification circuit outputs: 24VDC at 6 amps 1 4 2 Class A or 4 Class B, or 1 Class A & 2 Class B 3.0 (6.0 amps total) 20.4 to 27.3 VDC at 3.0 amps each, 4.7Kohm EOL resistor required on each Class B circuit No. of inputs: 2 Input configuration: 2 Class B or 2 Class A Input voltage range: 9-32VDC Battery charging capacity: 7.0AH Ambient Temp.: 32°F to 120°F Mechanical Dimensions: 12.25"W x 16.0"H x 3.0"D Shipping Weight: 8 lbs. 14 oz. Color: Red Indicator Lights AC power on: Green Battery trouble: Yellow Ground fault: Yellow Auxiliary trouble: Yellow Output 1 trouble: Yellow Output 2 trouble: Yellow Output 3 trouble: Yellow Output 4 trouble: Yellow Approvals UL: 864 & 1481 NFPA: 72 Signal Circuit Output Signal Circuit Output MODEL 5395 BLOCK DIAGRAM Signal 1 Input Signal 2 Input (optional) 120 VAC LOCAL FIRE CONTROL DISTRIBUTED POWER MODULE 5395 Trouble Output (Alternative to notification circuit trouble.) Signal 1 Signal 2 Signal 3 Signal 4 Aux. Power SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 1-800-446-6444 or in Minnesota (612) 493-6435 FAX: (612) 493-6475 www.silentknight.com MADE IN AMERICA FORM #350744, Rev. 2/97 V INTELLIKNIGHT ACCESSORY Model SD500-FRCM-4 Contact Monitor Module and Model SD500-FRCM Mini Contact Monitor Module IntelliKnight's addressable contact monitor modules combine early warning with pin -point location ID. A combination that saves lives and property. Model SD500-FRCM-4 and SD500-FRCM (mini version) are addressable contact monitor modules for use with Silent Knight's IntelliKnight fire control panel. The SD500-FRCM-4 and SD500-FRCM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm activation devices. The SD500-FRCM-4 and SD500-FRCM function identically. The SD500-FRCM-4 Contact Monitor Module mounts to a 4 -square box. The SD500-FRCM Mini Contact Monitor Module fits inside a 4 -square or double -gang box. Both modules are Class B supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-FRCM-4 and SD500-FRCM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. Model SD500-FRCM-4 and SD500-FRCM Contact Monitor Modules The contact monitor modules expand the flexibility of the IntelliKnight system by allowing the use of contact type inputs. Typical applications include manual pull stations and water flow switches. Features • Single, contact monitor with Class B supervision. • Up to 127 modules per SLC loop. • SD500-FRCM comes mounted in plastic case. • SD500-FRCM-4 mounts to an alluminum plate and has an attractive ivory finish plate. • SD500-FRCM-5 addressable without removing from housing • Accepts up to 14 gauge wire. • Both modules UL Listed; comply with NFPA 72. CAUTION "M' VF Sf •VIC1N, 11 e i S0500-FRCM-4 Operation Each contact monitor module is programmed with a unique SLC loop address. The module supervises the wiring of the contact with an EOL resistor. If a fault occurs in the wiring, the module alerts the FACP. SILENT KNIGHT 0 Specifications Operating Voltage: sc e A ru* 5 f IN • • • • •• SD500-FRCM 17-31 VDC Standby Current: .55 mA Alarm Current: .55 mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: SD500-FRCM-4: double gang box SD500-FRCM: inside 4 -square or double gang INTELLIKNIGHT ACCESSORY Model SD500-FRCM-4 and SD500-FRCM Contact Monitor and Mini Contact Monitor Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable contact monitor modules Silent Knight SD500-FRCM-4 or SD500-FRCM. The modules shall be UL listed compatible with Silent Knight's IntelliKnight 5820 fire panel. The SD500-FRCM-4 shall be supplied with a plastic cover plate and shall be suitable for mounting to a 4 -square electrical box. The SD500-FRCM shall fit inside a 4 -square or double -gang electrical box. The contact monitor module board must provide a monitor LED that is visible from outside cover plate (if the SD500-FRCM-4 is used). MODEL SD500-FRCM-4 CONTACT MONITOR MODULE FRONT VIEW BACK VIEW SIDE VIEW 4-7/8" CAUTION 'EM;rVr r,'WER =3:1(4P 'L SE' VIC1 U tih`..1 OEM 1 4-7/8" MODEL SD500-FRCM MINI -CONTACT MONITOR MODULE 1 3-1/16" FRONT VIEW O 2-1/16"—+ BACK VIEW SIDE VIEW -►i --14- 1/4" 1-1/2" SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350321, Rev. 6/97 Copyright © 1997 Silent Knight Security Systems 4 INTELLIKNIGHT ACCESSORY Analog / Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnight photoelectric smoke detectors. IntelliKnight photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is immediately recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector sensitivity testing is simple — even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal -resistant locking and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS Analog / Addressable Photoelectric Type Smoke Detector The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible smoke particles. The detector features automatic compensation for contamination and a simple detector sensitivity test procedure that can be run from the panel or remotely (using the IntelliKnight 5590 or 5595 software with a WindowsTM based computer). Operation The SD505-APS unit is made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event of fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector sensitivity testing through the control panel or remotely through a Windows- based computer. (5590 or 5595 software required for remote testing.) Adjustable sensitivity Vandal -resistance locking features Field cleanable The SD505-APS is Underwriters Laboratories Listed and meets the requirements outlined in NFPA 72 Inspection Testing and Maintenance, Chapter 7. SD505-APS Smoke Detector Specifications Operating Voltage: 17-41 VDC Current Consumption: Standby: Alarm: .55 mA .55 mA Ambient Temperature: 32°F to 122°F, (0°C to 50°C) Mounting: 4" SQR, 4" OCT, Single gang mud ring SILENT KNIGHT INTELLIKNIGHT ACCESSORY Model SD505-APS Analog / Addressable Photoelectric Type Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, analog / addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head and twist -lock base shall be UL® listed compatible with Silent Knight's IntelliKnight 5820 fire panel. The base shall permit direct interchange with Silent SD505-AIS Ionization Smoke Detector or SD505-AHS Heat Detector. Base shall be the appropriate twist -lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The sensitivity of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal -resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. It shall be possible to perform a functional test of the detector without the need of generating smoke. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. H Diameter = 5-15/16" SILENT KNIGHT Model SD505-6AB Detector Base (front view) II Diameter = 3-15/16" Height = 2 inches, including base Model SD505-APS Detector Head (front view) SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350330, Rev. 1/97 Copyright © 1997 Silent Knight Security Systems INTELLIKNIGHT ACCESSORY Analog / Addressable Heat Detector IntelliKnight addressable heat detectors combine ink accurate heat detection with pin -point location ID. ve An essential combination for any installation. ,!P 1 IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. And, because the IntelliKnight panel recognizes each detector by its specific address, precious seconds are not wasted in determining location of an alarm. Like other IntelliKnight detector models, the SD505-AHS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detector: easy installation, stable operation, RF/transient protection, and vandal -resistant locking and it adds up to a flexible solution for all your fire protection needs. Model SD505-AHS Analog / Addressable Heat Detector The SD505-AHS is a heat detector suited to virtually any commercial setting. The SD505-AHS is an absolute temperature device. This means that it responds to an alarm immediately if the temperature goes above the trip paint (programmed at the panel). The SD505-AHS provides accurate temperature measurement data to the fire alarm control panel. This heat detector is particularly suited to environments where smoke detectors cannot be used because of the presence of steam or cooking fumes such as in a kitchen. Operation The SD505-AHS unit is made up of an externally mounted thermistor with a specially designed cover that protects the thermistor while allowing maximum air flow. The thermistor reads the temperature from the air it takes in. It then transmits an analog signal representing the temperature to the IntelliKnight panel. If the temperature exceeds the trip point (programmed at the panel), an alarm occurs. The status LED lights continuously during the alarm period. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. Features • Low profile, 2 inches, including base • Absolute temperature device • Simple and reliable addressing • Uses digital communication protocol • Built-in fire test feature The SD505-AHS is Underwriters Laboratories Listed and meets the requirements outlined in NFPA 72 Inspection Testing and Maintenance, Chapter 7. SD505-AHS Heat Detector Specifications Operating Voltage: 17-41 VDC Current Consumption: Standby: Alarm: .55 mA .55 mA Detection Temperature 135°F to 150°F Range: (57°C TO 65°C) Ambient Temperature: 32°F to 100°F (0°C to 37°C) Mounting: 4" SQR, 4" OCT Single gang mud ring SILENT KNIGHT INTELLIKNIGHT ACCESSORY Model SD505-AHS Analog / Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, analog / addressable heat detector Silent Knight SD505- AHS. The combination detector head and twist -lock base shall be UL8 listed compatible with Silent Knight's IntelliKnight 5820 fire panel. The base shall permit direct interchange with Silent SD505-APS Photoelectric Smoke Detector or SD505-AIS Ionization Smoke Detector. Base shall be the appropriate twist -lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal -resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. 14 Diameter = 5-15/16" KNIGHT Model SD505-6AB Detector Base (front view) Diameter = 3-15/16" N N Height = 2 inches, including base Model SD505-AHS Detector Head (front view) ft‘ SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350332, Rev. 1/97 Copyright © 1997 Silent Knight Security Systems s q�� WASHINGTON SURVEYING AND RATING BUREAU 2003 WESTERN AVENUE, SUITE 300 SEATTLE, WASHINGTON 98121-2190 June 13, 1997 PLAN SHEETS 1-3 of 3 SUBJECT Homestead Village 15635 West Valley Highway Tukwila, Washington The attached plans have been reviewed as follows: The following revisions or additions to the design as shown would qualify the protection for improved rates based upon information shown on these plans. Arrangements should be made to allow a representative of this Bureau to complete a cover inspection of all piping before it is concealed by building construction, and to witness tests of the local water motor alarm and water supply test pipe (main 2 -inch drain). Completed copies of the Contractor's Material & Test Certificates for both the overhead and underground piping should be submitted to this Bureau. All piping, valves, and fittings should be listed and labeled by UL for fire service and installed, tested, and flushed in accordance with NFPA standards. A minimum temperature of 40°F must be maintained with a thermostatically controlled heating system in all areas containing wet pipe sprinkler equipment. 1. Heat tape is not acceptable. Heat all areas containing wet pipe sprinkler equipment. 2. Provide full height elevation of building showing complete details of construction, including roofing materials, ceiling and floor blind spaces, slab thicknesses and supports, etc. 3. Provide detailed information regarding location of flow test, number and diameters of outlets flowed, pitot pressures, whether or not stream straighteners were used, and static and residual pressures. Adjustments should be made in flow test to accommodate for changes in elevation. 4. Reserve 150 gpm for inside hose allowance and 500 gpm for outside hose allowance. 5. Operation of dry pipe system to be in accordance with Article 3-2.3.1* and exceptions of NFPA 13 (1996), such that water reaches the inspectors test within 60 seconds after it is opened. Drains should be provided for all trapped piping in dry pipe system as specified in Article 4- 14.3.5.3 of NFPA 13 (1996). Provide gang drains for multiple trapped branch lines. 6. Provide a variable pressure alarm valve and outside water motor alarm gong. 7. Replace 11/4 -inch drain with 2 -inch drain. 8. Extend sprinkler protection to all areas including exterior eaves, soffits, canopies, and to roof skylights. \n %gat tgum rpa5h�n� aEy�w� A H� � S Milt. ‘14AS to relab� a be catan exciusinei eY a�e pot to cam —manses gates "due mems @9' acctr insurance ,i *WV... n�� 11f ..� iue •the 4� or 9° �rious coo*. M arr`! Ma'i 100 as beat• d *Alt resPec�th W ° . bazar • > er4l tt 'hes tin exp tzri Wag to �p RI / . resinio s 3 4 () m 16 O I1—\ ( O 4 4 F 4 2' PI PE ACC Zf Without Comments As Noted in Red ® Per The Attuned Letter These plans have b :ef reviev ed by The Tukwila Fire znance Ir;;ri o current City �,.e,,,er!tEon Bureal..t for czar ,or . �;,.,t eC �� e.rrars and zr�dards. Acceptancs_ is adopted �hlCh r.� n;>; ::1i}C�!'.:°u v;Js7:Z.10(1 ofP .,t1i�,q�;E�intti �h, o �;�}c.,k'-iEls.}� for the 'Sndards and 0r d r JfCc.q$, The i :i , 4 li ° With the designer. igner. re,;Sl„p ? cy ' .. I i ner'e drawings s after dares, ill vOid ` c. -,pt =ice wiii require a 'e,ubrnittal of revised ore vvi. _ 3{ie subsequent app ':nal acceptance is subject to field test and inspection by E I , pe Tukwila Fire Prevention Bureau. 1. TUKWILA FIRE DFp1a `ENT Please call 2G6-57!.3-4407 and give this Fire Permit No. i'3- _ _07) and exact adds for shut- down hutdown or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing DSC - Product Approvals Internet and GPRS Dual -path Alarrn Communicator TL265GS T -Link Universal IP Alarm Communicator TL300 About Tyco I Privacy Policy I Terms of Use I Careers Contact Us I Send Feedback Copynght 02005 Tyco International All rights reserved ISO 9001 Registered North America Edoon Page 2 of 2 >> Extended Access http://www.dsc.com/index.php?n=library&o=approvals 2/14/2013 IX- Without Comments 0 As Noted in Red 0 Per The Attached Letter :"-iese plans have been reviewed by The Tukwila Fire sentIon Bureai..1 I'm conformance witti current City ,•?ndards, ACCeP subject to errors and i)ssions which 6..n ro: authorize violations of adopted 3ndards and The responsibility for the :quacy of des estotally with the designer. deietion sons to these drawings after date wilS voidthiF., zcc..eptance and will require a iesubmit-tai of vd :Pao/rigs for subsequent approval, nal acceptance is oi,it)ject o field test and inspection by The Tukwila Fire Prevent 3;,7 -eau. Date: ‘-.)% 9 By: it I Fire Permit Number .1- r--/7 To schedule inspections call 206-575-4407 5.5 Wiring Diagram ANTENNA Battery wire should be at least %inch apart from AC wires CAUTION: INCORRECT CONNECTIONS MAY RESULT IN DAMAGE TO UNIT. Opt ona I Bat ery OPTIONAL CONNECTION: (TWO TELCO CONNECTIONS FROM THE ALARM PANEL SPLICED INTO THETG-7FS) EARTH GROUND AC (12V 800MA) TO EXTERNAL TRIP INPUT Alarm Panel G� to+0o+0 `COO'9` O 0 Note: Drawing available as a CAD file. WARNING: HIGH VOLTAGE 0 ■ 0 PRESENT ON PHONE UNES. 1 0 System Status 2 0 DISCONNECT PRIOR TO SERVICING. LEDs 3 0 4 0 5 0 6 O ,� 44 r= R • I I I SIM Power IED 8 0 LED Mode Toggle Baton TELGUARD TG-7FS LTE Battery STC2 Connector <•. ��. aT (N.C.) SJOrIT 0 ir��r� gr�'o"or' 6'r1 �iler CAUTION: INCORRECT CONNECTIONS MAY RESULT IN DAMAGE TO UNIT. Opt ona I Bat ery OPTIONAL CONNECTION: (TWO TELCO CONNECTIONS FROM THE ALARM PANEL SPLICED INTO THETG-7FS) EARTH GROUND AC (12V 800MA) TO EXTERNAL TRIP INPUT Alarm Panel G� to+0o+0 `COO'9` O 0 Note: Drawing available as a CAD file. 12 • 61.7. ED DRAPTSTOPPN6 6TAEDER TO OTNER NDE OP C{iYE AT MIDPOINT ABOVE EACH WR L• . ' r t , TOP Q PLATE D•'.1 6/6• -)6 NMILATIOI WIN VAPOR SAMMIE 1'EIbRANE CN WARM NOP• RE. OPEC ROOF/ CE IL1 ANIETIELT RE. 1/A1.A GUESTROOM GUESTROCM 1R• O1T ED DRAFT/TOPPNG •NI61.11LOOR A6 6C.-'+. • .D 6ECONO !LOOK GU!BTROOM OATT INDILATIGI . ILOOR/CEILN6 AN6EPIELT RH. 2/A•A 6UBSTROOM COSSTROOM 141OUR RATED MANE WALL PIE. AIM AIA PNLH FLOOR • A6 6CF6•S u T• ,L4N PCOOR . 100 -0' .. c, t' Pw1DAnoN R• /TR1CTURAL - • - 11/7 .4407 111lT,L1E NOULAT10N 0116315.1.. UNDER ALL EM660111- • •WALL SECTION - OP POMDATION t11N,L/ .• • SCALE. 1/4"d-0•• O�'� v'Pa e./NIIIER oN 6141,1/Dt :V n. — i • • 6 1. •'r 1 , 1 , 1 .. - • .1 .1 1 . :r 1- 1 rt ' `. TO: rM.ATE! • 1• - TANDARD 4••••••......••••• 1 1 1 t 207 • n • 1 STANDARD 1t► -1 . / 1 / 1 1 • j 102 BUILDING SECTION - SCALE. 118'1'-O' 11. • 1 r/ / 1 • i / t15'-6 ter� I'TW1-er0o • :.103'-S 1/4' . 19741844 fi0F{ I'.m. - 1 • • 1 • • 1 • 7 • • UNDERGROUND NOTES 1. ALL UNDERGROUND TO BE RODDED AND! OR BLOCKED PER NFPA 24. 2. N:UdIMUM BURY IS 3'. 3. SMITH FIRE SYSTEMS IS TO START 5' OUTSIDE THE BUILDING AT A 4' LINE LEFT BY OTHERS. 4. ALL UNDERGROUND MATERIALS ARE TO BE LA LISTED FOR FIRE SERVICE. 5. THE UNDERGROUND FIRE SERVICE IS TO INCLUDE A YARD POST INDICATOR VALVE, A 4' DDCVA IN A VAULT ANDA 2 112 x 21/2 x 4 YARD F.D.C., ALL BY OTHERS • 0 • TO BURIEN VICINITY MAP WATER INFORMATION STATIC RESIDUAL FLOWING ELEV. OF TEST LOCATION OF TEST HYDRANT EASTBOUND I-405 OFFRAMP SMITH FIRE SYSTEMS START POINT • )RISER R N FDL IN YARD PI IN VAFD vBALKKlv 1.; • r1 ANN AN /AN, // ti 7 Ivr 1 147 PSI 100 PSI 1300 GPM SAME AS SITE #114 STRANDER FH 1 1 1 1 1 1 1 1 Alltlit0100000090.tr.imitql0 it 11 1 1 11 11 11 11 14 11 1 11 11 11 11 11 11 11 11 11 1 11 11 11 It 1 it 11 11 H 1 u 11 11 11 1 11 11 11 11 11 11 0 6 1 11 11 u 11 11 11 41 11 11 1t 11 11 u 11 It u 11 u 11 1: f Arl SITE PLAN SCALE: 1/20" = 1'-0" 1, 11 11. 1•. FILE HANGER LEGEND SPRINKLER LEGEND SYM MANUFACTURER TYPE MODEL HEAD FINISH ESCUTCHEON ORF ICE THREAD TEMP OUANTITY FINISH SIZE SIZE RATING TOTAL THIS SHEET A AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO BBREVIATIONS SYMBOL LEGEND REVISIONS ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK - BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT OF SUIT - FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO SPRINKLERS UNLESS NOTED OTHERWISE 0 CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE 4 -WAY EARTHQUAKE SWAY BRACE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE NO. DATE BY REASON FOR REVISION CONTRACT WITH TITAN CONSTRUCTION CO. 11061 NE 2ND STREET, SUITE 200 BELLEVUE, WA 98004 PHONE: (206) 454 -8120 - FAX.: (206) 451-0380 CONTACT: HAL SIGNETT j' R7 5 SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East Tacoma, WA 98424 CONTR. REG. NO. SMITHFS1360T Ph: (206) 926-1880 • Fax: (206) 926-2350 PROJECT HOMESTEAD .VILLAGE 15635 WEST VALLEY HIWAY TUKWILA, WA - DESIGNER DATE SHEET JOB NO. POMMERT 4-16- 97 1 OF 3 R305 r /� 47270 UNIT MIX DATA FIRST FLOOR . 18 STD. a AccESe.I Km Dip': SACIKMi____ DELUXE IV ROLLIN ACCE55.1 DSD WIT UNIT I 5 1 e FLOOR 1 le 3 ?WORD FLOOR 18 s TOTALS � I1 1 3 34 10 ;28 X13 TOTAL 1,41141ER OR ACCESieldLE F }'IaR8045 W114 AA.RMGii ?MPAP NTi+ 4 taSCEUNtOUSi FIRE a eTEM TRAVEL pISt6WCE TO Ex1Te FULLY . NOT TO ID CEED 150' TELCO 1 TELCO 2 120 VAC N. • �rVVrrrrid rPr V V V rrrrrrrrrrr 9 ® 009 S 4/4 14 /dAZWRZHang SIGNAL : 2ND FLOOR NE a[ZhZ4Z-Z417}04Z-VA 4/1 F n 0© • rii pprrprArrrri►rrpr rrrrrrAr rrrEli rrrr 000099® F 09S®0 0 s LNITIATING : 3RD FLOOR NW 0 F LNITIATING : 3RD FLOOR NTE INITIATING : 2ND FLOOR NW 0 000GI11 0000 0 s .s s F t RELAY: PRIMARY FLOOR, ELEVATOR RE -CALL "-RELAY: ALTERNATE FLOOR, ELEVATOR RE -CALL 1 ----RELAY: ELEVATOR SHAFT PRESSURIZATION FAN IRELAY: MAGNETIC DOOR HOLDERS INITIATING : 2ND FLOOR NE 000 0 IN 0 F 41) cn Ev'_ INITIATING : 1ST FLOOR NW SIGNAL : 1ST FLOOR NW SIGNAL : 1ST FLOOR NE INITIATING : 1ST FLOOR NE r rrrrr rrr rr► rr r rr r r r 7 rrr►r r►rr►►r►►rrrrrr►rr rrrrrrrrrr►rr-rrrrrrrrrrr--rrr Lol EOL SIGNAL : 3RD FLOOR NW SIGNAL : 3RD FLOOR NE SIGNAL : 2ND FLOOR NW RISER DIAGRAM FIRE ALARM LEGEND PO BOX 3232 KTRKLAND WA Iff033 (425W21-9633 FAX: 142-41821-6546 . Laid FIRE ALARM CONTROL PANEL (FACP) P s AUXILIARY POWER SUPPLY IANN REMOTE ANNUNCIATOR MANUAL PULL STATION - 0 SMOKE DETECTOR Q LOCAL - IN ROOM SMOKE DETECTOR Q FIXED TEMP HEAT DETECTOR A FIXED TEMP HEAT DET(interstitial space) WATERFLOW SWITCH ? PRESSURE SWITCH TAMPER SWITCH MINI HORN jHORN4 - STROBE MINI HORN/STROBE BELL AO ' BELUSTROBE El MAGNETIC DOOR HOLDER Ell END OF LINE RESISTOR - Taw#,I.IA FjgE DEPARTML. Pigase call: 575,4407 and give this job No. and exact address for shut' dawn or restoration approval. IL MAY 2 1 197 Ter ,744gttgirl s iH .rp43-6,(1. Sc e or 6-1/4J-Q-c� rbtin%s t bcc011idtZ. c ake*aC 5 lW Sioc'SS-t- r oomS, ACCEPTED Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: SI ester? By: 510 FILE SYSTEMS TECHNOLOGY PO BOX 3232 KTRKLAND WA Iff033 (425W21-9633 FAX: 142-41821-6546 . SCALE: 3/32=1'- 0" . DATE: 5-1.1-97 DRAWN BY: JW J OMESTEAD VILLAGE 15635 WEST VALLEY HWY TUKWIL A WA 98188 - FIRE ALARM PLAN , SITE PLAN Fl Nch '�C `FIRE SRR1NKLER ROOM COMMON LA UNDRY '7 LEC. ROOM LINEN WORK AREA TO PHQ 2N0 ROOM ELEV I w hZ 60 M FRST FLOOR PLAN SCALE 3/3z" -i'- 0" NORTH -c1- PIV L SYSTEMS TECHNOLOGY PO BOX 3212 KTR KLA ND) WA 9511133 {42()R2I-%3.3 FAX: (4240121-4414 SCALE: 3/32=1'- 0- DATE: 5-14-97 DRAWN BY: JW - - • HOMESTEAD VILLAGE 15635 WEST VALLEY HWY TrK\`TLA WA 98188 FIRE ALARM PLAN 1st FL PLAN F2 3 :J i SECOND FLOOR PLAN. SCALE• 3/32'1=0" NORTH SYSTEMS TECHNOLOGY PO BOC 32112 KIRKLAND WA 99833 (4251S21-9633 FAX: (42502145% SCALE: 3/32=1'- 0" DATE: 5-14-97 DRAWN BY: JW HOMESTEAD VILLAGE 15635 WEST VALLEY HWY TUKWILA WA 98188 FIRE ALARM PLAN 2nd FL PLAN F3 THIRD FLOOR PLAN SCALE. 3/32"-1=0'l NORTH SYSTEMS TECHNOLOGY PO BOX 332 EQRKLA 1D W. 93013 I42 21-9633 FJ.X: 132511121-65% SCALE: 3/32=1'- 0" DATE: 5-14-97 • DRAWN BY: JW HOMESTEAD VILLAGE 15635 WEST VALLEY HWY TCKWTLA WA 98188 FIRE ALARM PLAN 3rd FL PLAN F4 • VICINITY MAP 4 TO SEATTLE 4, 4 4 • RENTON • • NOT TO SCALE , • t stre/', scuil4ciENTER 4, TAA • • t 'TUKWILA • • , 1 ▪ .- ♦ . 44 y t . j R ,. .r' ▪ .R y 4 ' ` 4 5 Rt • I 1r ti Fr • 1 t i • `4t aS -, S % A r ~ .- 'S, f" .1 � t 1r11� .S ..I w. a 4,- r R ..,/ t ► • 4. • WHIT MX DATA fro STp t ACE KM DID( SdKP DEUDdE WtT ju, ROLLIN ACCESS 1 DiD wit trttT r — FlRbT FLOOR * 1 iiiii4— ' >s iItor 1-O�__t_� _ 1° __ Tum FLOOR 1 TOTALS 11 i3 '141' TOTAL KIPE5ERCP ACCESetISLE 1110011* *OR reatea4sWTN i.E,4RMQI 1MPAMe"ILNTS. 4 1 1 4' TOTAL. 32 1 • 34 93 $. MINE SYSTEM TRAWL DISTANCE TO EXITS FULLT NOT TO EXCEED NO' TELCO 1 TELCO 2 v . I. v. v r_rPrr_ir irrrrrrirr rirrirVrrrrrVVPrr II Ill c �J OC S C' INITIATING 3RD FLOOR NW CI 0©e0®s 04if ©©a=s all) 11 A9ia�3 1111 0 GA S S� SOF © RELAY PRLMARY FLOOR ELEVATOR RE -CALL r -RELAY ALTERNATE FLOOR ELEVATOR RE -CALL L_RELAY ELEVATOR SHAFT PRESSURIZATION FAN RELAY MAGNETIC DOOR HOLDERS 120 VAC — -- (b-3z\tOc. v13 S 0© S 9 s C-7 INITIATING 3RD FLOOR NE INITIATING 2ND FLOOR NW • INITIATING 2ND FLOOR NE S sa\F© F SIGNAL 1ST FLOOR `V ED t_ i SIGNAL 1ST FLOOR NE INITIATING 1ST FLOOR NW S 9 INITIATING 1ST FLOOR NE • • • • rrr rrrrr r rrrrr►►r►rrPA' rrrrrrr rPAI ria r PAP"LI ma 1r V rrrrr 14/z.. EOL EOL SIGNAL 3RD FLOOR NW SIGNAL 3RD FLOOR NE {U IL IL.J IL V RISER DIAGRAM 4 r TrL,E7r".-.,v-,- .5._ 14, O W_ IE e rf i �+t e .s As r :4tri Q Per Tn: -tar :I-3 1. -eater These pians have been revi,-- 'ec c' T ► e Tu,civisa Fire prevention BureaL for co irorfi -re w - current City ;'- rdards Atceocar..e s subje7 }' e:ro's a^d cess ons which do not autho' :e o ano"s of adopted s anda-ds aria orc ^ar•cesTr- ��� :Ts `� cv far the -it'':,'3ry of d esogr est totah 'tn r -e aes'gne' YL'dil4Onss, deletions : evisiors `o -"eLo drawings after i zr s date vi ' vG4\, t" z ceptar ce and ,' "Fau're a r sobrnitta cf re4is:�,' 5-awings tor sues- rOrt approiai ( The Tokv'.a Fre. Pe -e 3ureau viral acceptance ,o held test a'id Inspection bi 1 Catekb_e� 1 TUKWILA FIRE DEPARME T cal 206-575-4407 End g ye pis Fire Permit No, I — -o-1z. ena. alteS3 for shy- PA1 XP; 13 NM TUKWILA FIRE SIGNAL 2ND FLOOR NW SIGNAL 2ND FLOOR NT TOWI pl@ase ca and give th and exact a down or r FozE 57 ?NaTML 4407 dre torati for shut' approval. Oai-+abut.. 't�i�s ire 6 � robwts ;�,r orc�. 1.4Z. �HsCk� .S Mr�Fe or Ir ,-� Cks�e`\eC 5 IN JtdCc s ..r(to +els, ACCEPTED ❑ Witho t Comments As No ed In Red O Per - - Attached Le r These plans have been Prevention Bureau for c standards Acceptance i omissions which do not a standards and ordinance adequacy of design res Additions deletions o this date will void th resubmittal of revi eviewed tlform su t evisi accep ed drawn The Tukwila Fire ce with current city ct to errors and t • nze violations of adopted The responsibility for the ally with the designer ns to these drawings after nce and will require a for subsequent approval Final accepta ' - is subject to - Id test and inspection by The Tukwi - ire Prevention Bu =au Date Z9 °I By 5 /0 r FILE SYSTEMS TECHNOLOGY FIRE ALARM LEGEND SCALE 3/32=1 - 0" D -ATE 5-14-97 DRAWN BY AN FIRE ALARM CONTROL PANELF( CP) F/61 AUXILIARY POWER SUPPLY Min REMOTE ANNUNCIATOR MANUAL PULL STATION 0 , SMOKE DETECTOR Q LOCAL - IN ROOM SMOKE DETECTOR Q FIXED TEMP HEAT DETECTOR A FIXED TEMP HEAT DET(mterst►hal span.) WATERFLOW SWITCH P PRESSURE SWITCH TAMPER SWITCH IA MINI HORN Iil HORN STROBE MINI HORN/STROBE BELL BELL/STROBE I] MAGNETIC DOOR HOLDER FrfQ END OF LINE RESISTOR TrL,E7r".-.,v-,- .5._ 14, O W_ IE e rf i �+t e .s As r :4tri Q Per Tn: -tar :I-3 1. -eater These pians have been revi,-- 'ec c' T ► e Tu,civisa Fire prevention BureaL for co irorfi -re w - current City ;'- rdards Atceocar..e s subje7 }' e:ro's a^d cess ons which do not autho' :e o ano"s of adopted s anda-ds aria orc ^ar•cesTr- ��� :Ts `� cv far the -it'':,'3ry of d esogr est totah 'tn r -e aes'gne' YL'dil4Onss, deletions : evisiors `o -"eLo drawings after i zr s date vi ' vG4\, t" z ceptar ce and ,' "Fau're a r sobrnitta cf re4is:�,' 5-awings tor sues- rOrt approiai ( The Tokv'.a Fre. Pe -e 3ureau viral acceptance ,o held test a'id Inspection bi 1 Catekb_e� 1 TUKWILA FIRE DEPARME T cal 206-575-4407 End g ye pis Fire Permit No, I — -o-1z. ena. alteS3 for shy- PA1 XP; 13 NM TUKWILA FIRE SIGNAL 2ND FLOOR NW SIGNAL 2ND FLOOR NT TOWI pl@ase ca and give th and exact a down or r FozE 57 ?NaTML 4407 dre torati for shut' approval. Oai-+abut.. 't�i�s ire 6 � robwts ;�,r orc�. 1.4Z. �HsCk� .S Mr�Fe or Ir ,-� Cks�e`\eC 5 IN JtdCc s ..r(to +els, ACCEPTED ❑ Witho t Comments As No ed In Red O Per - - Attached Le r These plans have been Prevention Bureau for c standards Acceptance i omissions which do not a standards and ordinance adequacy of design res Additions deletions o this date will void th resubmittal of revi eviewed tlform su t evisi accep ed drawn The Tukwila Fire ce with current city ct to errors and t • nze violations of adopted The responsibility for the ally with the designer ns to these drawings after nce and will require a for subsequent approval Final accepta ' - is subject to - Id test and inspection by The Tukwi - ire Prevention Bu =au Date Z9 °I By 5 /0 r FILE SYSTEMS TECHNOLOGY PO BOX 3202 KIRKL AND WA 919033 (1251/421 %33 FAX (-12.513'1-t% SCALE 3/32=1 - 0" D -ATE 5-14-97 DRAWN BY AN I.OMESTEAD VILLAGE 15635 WEST VALLEY HWY TL K'*`TL Y « A 9.8188 FIRE ALARM PLAN SITE PLAN rFll ./T ,—fin FIST FLOOR PLA\ SCALE 3/3'4"11 g„ NORTH V A L SYSTEMS TECHNOLOGY , PO BOX 32/12 KTR KLA'` 1) WA 9f111333 (421)R21 %)) FAX 14210%21-4A% SCALE: 3/32=1'-13- D &TE: 5-14-97 DRAWN BY: JW HOMESTEAD VILLAGE 15635 WEST VALLEY HWY TL'KWIL4 W'A 98188 FIRE ALARM PLAN 1st FL PLAN F2 1 E • It k! t SECOND FLOOR PLAN tCAL.L• 3/3'wt =0" NORTH SYSTEMS TECHNOLOGY PO BOX 3252 KIRKLAND WA ,5033 (4251521 %33 FAX (425{524 145% SCALE. 3132=1'- 0" D aTE. 5-14-97 DRAWN BY: JW HOMESTEAD VILLAGE 15635 WEST VALLEY HWY TUKWILA WA 98188 FIRE ALARM PLAN 2nd FL PLAN F3 THIRD FLOOR PLAN SCALE 3/32"<-0" NORTH SYSTEMS TECHNOLOGY PO BOX 3282 KIRKLAND w 4 93033 142_1321 96.33 FAX (423)921-496 SCALE• 3/32=1'- 0" DATE- 5-14-97 DRAWN 131 • JW HOMESTEAD VILLAGE 15635 WEST % ALLEY HWY TLK\VTLAWWV 98188 FIRE ALARM PLAN 3rd FL PLAN F4 MAIN __ F,0.5, 0 RISER'S 8. 412 ]6'2 , 1g- j14 2/ I- :q,L RISER PLAN VIEW 0 2 4 r SCALE 1/2"=1'-0" c4 AO `11iff 1111 1111 _ H "2 PI PE STAN C RISER DETAIL ,42 RED IBJ -110111112 0 2 SCALE 1/2"=1'-0" RISER EQUIPMENT 4 RED 13 =0 14 0 ITEM QTY. 1 3 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 3 3 3 3 3 1 SIZE DESCRIPTION 3" 2" 114" 1/2" 3" 1" 10" 1/2" 4" 4" 1/2" 2' BUTTERFLY VALVE WITH BUILT-IN SUPERVISORY SWITCH MAIN DRAIN PRESSURE GAUGE ASSEMBLY PRESSURE RELIEF VALVE WATERFLOW INDICATOR INSPECTOR'S TEST VALVE ELECTRIC BELL DPV FILL UNE VALVE WAFER BUTTERFLY VALVE WITH BUILT-IN TAMPER DRY PIPE VALVE PRESSURE SWITCH HIGH / LOW PRESSURE SWITCH AIR MAINTENANCE DEVICE MAIN DRAIN MANUFACTURER GRUVLOK POTTER ELECTRIC POTTER ELECTRIC KENNEDY GEM POTTER ELECTRIC POTTER ELECTRIC GEM 600 GAL. AIR COMPRESSOR GAST 12 -HEAD SPARE HEAD CABINET CONTAINING THE FOLLOWING: MODEL # GN7722-3FD VSR-F PBA 12010 93W1 F 3021 PS 10-A2 PS40-A2 F 324 6LCF-13-M616X SPARE SPRINKLERS & WRENCHES SPRINKLERS MANUFACTURER TYPE MODEL FINISH ORIFICE THREAD TEMP. QTY. RELIABLE SSU G BRONZE 1/2" 1/2" 165°F 1 RELIABLE SSU G BRONZE 1/2" 1/2" 212°F 2 RELIABLE a SSP,FIFR 0.125 WHITE 1/2"2" 1 155°F 2 RELIABLE SSP F1FR WHITE 1/2" 1/2" 200°F 1 REUABLE REC-SSP FIFR/F2 WHITE 12" 12' 155°F 2 REUABLE i REC-SSP F1FR/F2 WW HIT 17/32" 3/4" 155°F 2 REUABLE HSW FFR CHROME 12" 1/2" 155°F 1 RELIABLE HSW G BRONZE 1/2" 1/2" 165°F 1 WRENCHES RELIABLE MODEL D I 1 GENERAL NOTES. 1. DISCHARGE MAIN DRAIN TO A SAFE LOCATION OUTSIDE / FLOOR DRAIN. 2. MAINTAIN A 2" ANNULAR SPACE AROUND PIPES PASSING THRU CONCRETE FLOORS. 3. ALL GROOVED COUPLINGS ARE RIGID UNLESS NOTED WITH A ( F ► WHICH ARE FLEXIBLE. HANGER LEGEND r s SYSTEM NO. 1 DRY ATTIC AREA AREA SQ. NUMBER OF DESCRIPTION FOOTAGE SPRINKLERS ATTIC 15,539 188 HYDRAULIC CALCULATION DATA DESIGN DENSITY: .15 GPM / 1,950 SQ. FT? ACTUAL DENSITY: .16 GPM / 2,076 SQ. FT. DEMAND AT BASE OF RISER 444.90 GPM AT 104.46 PSI (0 GPM INSIDE HOSE ALLOWANCE DEMAND AT CITY CONNECTION 694.90 GPM AT 114.93 PSI ( 250 GPM TOTAL HOSE ALLOWANCE ) DRY SYSTEM CAPACITY: 430 GALLONS. SYSTEM NO. 1 WET SYSTEM 1ST FLOOR AREA DESCRIPTION HOTEL/MOTEL AREA SQ. FOOTAGE 15,538 NUMBER OF SPRINKLERS 116 HYDRAULIC CALCULATION DATA DESIGN DENSITY.. -.15 GPM /1,500 SQ. FT. ACTUAL DENSITY: .15 GPM / 1,508 SQ. FT. DEMAND AT BASE OF RISER 314.24 GPM AT 85.88 PSI ( 0 GPM INSIDE HOSE ALLOWANCE DEMAND AT CITY CONNECTION 564.24 GPM AT 94.63 PSI ( 250 GPM TOTAL HOSE ALLOWANCE SYSTEM NO. 3 WET SYSTEM 3RD FLOOR (2ND FLOOR SIMILAR) AREA DISCRIOTION HOTEL / MOTEL AREA SQ. FOOTAGE 15,538 NUMBER OF SPRINKLERS 89 HYDRAULIC CALCULATION DATA DESIGN DENSITYz__.15 GPM / 1,500 SQ. FT: ACTUAL DENSITY: .15 GPM / 1,593 SQ.FT. DEMAND AT BASE OF RISER 290.83 GPM AT 66.31 PSI ( 0 GPM INSIDE HOSE ALLOWANCE ) DEMAND AT CITY CONNECTION 540.83 GPM AT 74.74 PSI ( 250 GPM TOTAL HOSE ALLOWANCE ) • • • • • • • • • • • • UNDERGROUND NOTES: 1) ALL UNDERGROUND PIPNG PAST 5'-0" OUTSIDE THE BUILDING TO BE BY OTHERS. CONTRACTOR TO BE STATE LICENSED AND CERTIFIED TO INSTALL UNDERGROUND PIPING PER WAC 212-80. 2) ALL UNDERGROUND PIPING SHALL HAVE 3' MINIMUM BURY (TO TOP OF PIPE). 3) AU. UNDERGROUND PIPING SHALL BE UL LISTED AND/OR FM APPROVED FOR FIRE PROTECTION. 4) ALL UNDERGROUND PIPING SHALL BE RODDED AND/OR BLOCKED IN ACCORDANCE WITH THE SPECIFICATIONS AND NFPA 24 (LATEST EDITION). 5) ALL UNDERGROUND PIPNG SHALL BE HYDRO- STATICALLY TESTED AT NOT LESS THAN 200 PSI OR 50 PSI ABOVE STATIC PRESSURE IN EXCESS OF 150 PSI FOR TWO HOURS IN ACCORDANCE WITH NFPA 24 (LATEST EDITION). 6) ALL UNDERGROUND PIPING SHALL BE FLUSHED IN ACCORDANCE WITH NFPA 24 (LATEST EDITION). FLOW THE REQURIED RATE UNTIL WATER IS CLEAR AS INDICATED BY NO COLLECTION OF FOREIGN MATERIAL IN BURLAP BAGS AT OUTLETS. 4" - 390 GPM 10" - 2,400 GPM 6" - 880 GPM 12" - 3,520 GPM 8" - 1,560 GPM 7) ALL UNDERGROUND PIPNG SHALL BE STERILIZED PER LOCAL JURISDICTION REQUIREMENTS. • • -/ • TO BURIEN VICINITY MAP r WATER INFORMATION. STATIC RESIDUAL FLOWING ELEV. OF TEST LOCATION OF TEST EASTBOUND 1-405 OFFRAMP SMITH FIRE SYSTEMS START POINT - 5:0"'ouT, ? R 15 E R RIX FDC IN YARD PI VAFD • • '"BALK TLC()) UUL. 1LKtiNs 4500*. • • • • ti AN; V rs, NN IN \ \` �l F 1 (44 �-T 1' 1 1 1 1 1 1 1 1 1 1 1 1 147 PSI 100 PSI 1300 GPM SAME AS SITE HYDRANT #114 @ STRANDER • 1111111I1t11111111111f11i11 1111111111111111111111111111111111111111111111111111111 jn11��11111111111 -�� SITE PLAN SCALE: 1/20" = 1 '-0" 41...1111110 1 _ GENERAL NOTES 1. ALL COUPLINGS WITH ( F TO BE FLEXIBLE. 2. ALL PIPE TO BE AS FOLLOWS: STEEL PIPE ASTM A-795 OR BETTER PIPE " SIZE SCHEDULE WALL THICKNESS INTERNAL DIAMETER ' END PREP TYPES ALLOWED • We1QHT of WATER 1 PIPE CAPACITY N GALLONS 1 40 0.133 1.049 THREADED, CUT GROOVED, ROU. GROOVED, PLAIN END. POLISHED 2.063 8.844 1 1/4 SUPER-FLO 0.059 1.542 ROLL GROOVED, POLISHED, PLAIN END ( FOR BUTT WELDING) 1.817 8J087 1 1/2 SUPER-FLO 0.074 1.762 ROLL GROOVED, POLISHED, PLAIN END ( FOR BUTT WELDING) 2.448 0.125 2 SUPER-FLO 0.074 2.227 ROLL GROOVED, POLISHED, PLAIN END ( FOR BUTT WELDING) 3.414 8.202 2 1/2 SUPER-FLO 0.074 2.727 ROLL GROOVED, PLAIN END ( FOR BUTT WELDING) 4.734 8.303 3 SUPER-FLO 0.074 3.352 ROLL GROOVED, PLAIN END 1 FOR BUTT WELDING) 8.628 8.451 4 SUPER-FLO 0.074 4.352 ROU. GROOVED, PLAIN END ( FOR BUTT WELDING) 1.127 5.773 5 10 0.134 5.295 ROU. GROOVED, PLAIN END (FOR BUTT WELDING) 17.300 1.144 6 •• 0.134 6.357 ROU. GROOVED, PLAIN END (FOR BUTT WELDING) 23.030 1.640 8 •• 0.188 8.249 ROLL GROOVED, PLAIN END (FOR BUTT WELDING) 40.080 2.78 •• WALL THICKNESS PER NFPA /13 4 11 11 11 1111 11 11 11 1 11 11 11 4 11 11 11 11 11 11 11 11 4 11 11 11 11 n 11 11 1' SCOPE OF WORK SMITH FIRE SYSTEMS (SFS) WILL PROVIDE A WET PIPE FIRE SPRINKLER SYSTEM TO PROTECT THE HEATED PORTIONS OF THE BUILDING. SEPARATE FLOOR CONTROLS WILL BE LOCATED IN THE FIRE SPRINKLER RISER ROOM LOCATED ON THE FIRST FLOOR. SFS WILL ALSO PROVIDE A I DRY PIPE FIRE SPRINKLER SYSTEM TO PROTECT THE UNHEATED ATTIC, WALKWAYS AND PORTE COCHERE. SFS WILL START 5'-0" OUTSIDE THE BUILDING. CLAIRIFICATIONS --- ALL AREAS ARE PROTECTED BY A WET SYSTEM AND MUST BE MAINTAINED AT A MINIMUM OF 40°F BY OTHERS TO PREVENT FREEZING. -- INSULATION CONTRACTOR TO PROVIDE TENTING OF ATTIC INSULATION OVER ALL WET SPRINKLER PIPING TO PROTECT THE SYSTEM FROM FREEZING. --- SFS ASSUMES THE STRUCTURE TO BE ADEQUATE TO SUPPORT THE SPRINKLER SYSTEM. --- SFS WILL PROVIDE FREEZE PROTECTION FOR THE WET SPRINKLER PIPING PASSING THROUGH THE UNHEATED CORRIDORS. --= ALL WORK TO BE PERFORMED DURNING NORMAL WORKIING HOURS. EXCLUSIONS - -- ,PAINTING OR LABELING OF SPRINKLER PIPING AND/OR EQUIPMENT. --- ELECTRICAL WIRING OF ANY KIND INCLUDING, BUT NOT LIMITED TO, ELECTRIC BELL, TAMPER SWITCHES, WATERFLOW SWITCHES AND AIR COMPRESSOR.. - -- CENTRAL STATION ALARM EQUIPMENT, WIRING AND MONITORING. - -- ALL UNDERGROUND PIPING BEYOND 5'-0" OUT. --- SMALL HOSE STATIONS. DESIGN CRITERIA HOTEL'/MOTEL & SUPPORT AREAS: PER NFPA 13 , 1994 EDITION ORDINARY HAZARD: .15 GPM / 1,500 SQ.FT. GROUP 1 UNHEATED ATTIC: It 11 11 11 4 1111 /, 11 11 11 4 4 11 4 7. tl n PER NFPA 13 , 1994 EDITION ORDINARY HAZARD: .15 GPM / 1,950 SQ.FT. GROUP 1 j- 1 1 . 11 ,i 11 11 4 4 4 11 4 1. 4 11 1. t. 11 . ,1 1- 1. 1' 1T A ARE DEPARTMENT Please call: 575-4407 and give this job SIS No. ck and exact address tor approval. down or restoration ACCEPTED �] Without CBmm+tS As Noted In Red Per The Attached Lear These plans have been conformance with cur entac city Prevention Bureau f standards. Acceptance is subject to errors and omissions which ordinances. nances. Theresponviolattons of s � hty for thadopted n standards and adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will f revisedeu will require a drawings for s resubmlttao subsequent approval. resubmittal Final acceptance is subject field test and inspection by The Tukwila Fire Date:t w By' Lr� Akin 011 � IP fa SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND REVISIONS SYM MANUFACTURER TYPE MODEL HEAD FINISH ESCUTCHEON FINISH ORFICE SIZE THREAD SIZE TEMP RATING QUANTITY 0 RELIABLE SS U FI FR BRoNZE 12 1(.5 iv TOTAL THIS SHEET AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT OF SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO SPRINKLERS UNLESS NOTED OTHERWISE 4 0 CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE 4 -WAY EARTHQUAKE SWAY BRACE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE NO. DATE BY REASON FOR REVISION Z -20117 WAB REVLSED ATTIC DENSIT`( TO .15GPM / I5g5o SQ. FT. 4- ( 1 , CONTRACT WITH TITAN CONSTRUCTION CO. 11061 NE 2ND STREET, SUITE 200 BELLEVUE, WA 98004 PHONE: (206) 454 -8120 - FAX.: (206) 451-0380 CONTACT: HAL SIGNETT SITE: MIKE WINNE (206)-204-1427 Ax (206)-204-1426 PAGER (206)-996-8551 L r • °I SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East Tacoma, WA 98424 CONTR. REG. NO. SMITHFS1360T Ph: (206) 926-1880 • Fax: (206) 926-2350 PROJECT HOMESTEAD VILLAGE 15635 WEST VALLEY HIWAY TUKWILA, WA DEtIGNER PQMMERT DATE SHEET 6-9-97 1 OF 3 JOB NO. R305 11. • 11, 1 i Ill l II 1 r OZ 22 4-0 ;II -12 F- • • • 1 _ a'-0 4 0 r • L_T EI4 I r- 1 7-O" ► melb 0 H • • QF.0.5. • t • 0 pv 00 i(Q- Q' 0(1 <° o O 00 Q 4 v��p q0'C 1 00 0c,lI� CI .. v 4) q'�PO4 L L ' ED 1 • iC171l. 1 /2" TJ/ z4 0 G.- 1' 0 1 N 0 L FREEZE PROTECTION: HEAT TAPE AND INSULATE 5'-6" LF OF PIPING THREE PLACES EACH ON FLOORS 1ST THRU 3RD. II78LVL L • • • • 912 TJ I 2XhXId,(4EA) I6d NAILS, WITH I" U -HOOK FOF. 14 PIF= 1=, 5' U-HUJK FOR 114.- 2' P11= EA) X16 X 2 DRIVE HANGER T4 P119 _ • 2-4-' v FREEZE PROTECTION: HEAT TAPE AND INSULATE 5'-6" LF OF PIPING THREE PLACES EACH ON FLOORS 1ST THRU 3RD. - _0 x9 I t N N I.F.0.S. I. F. o. 5. FITTER / LISTER NOTES ( IST & 2ND FLOOR ONLY ) 1. ALL DROPS ON THE WET SYSTEM ON P.O.L.'S ARE TO BE MEASURED FROM THE BOTTOM OF THE PIPE TO THE FINISHED CEILING. THIS DIMENSION IS 0'-8 1/2" U.N.O. 2. ALL DROPS ON THE WET SYSTEM ON 1" SCREWED PIPE ARE TO BE MEASURED FROM THE CENTERLINE OF THE FITTING TO THE FINISHED CEILING. THIS DIMENSION IS 0'-9 1/2" U.N.O. 3. ALL DRY PENDENTS AND DRY HORIZONTAL SIDEWALLS ARE TO BE FIELD ORDERED.SEND 1 (1'-0" I NIPPLE AND CAP FOR ALL DRY PENDENTS AND 1 ( 0'-6" I NIPPLE AND CAP FOR ALL DRY HOIZONTAL SIDEWALLS. 4. HANGER SPACING TO BE AS FOLLOWS: 1 1/4" AND LESS : 12'-0 O.C. MAXIMUM. 1 1/2" AND GREATER : 15'-0" O.C. MAXIMUM. 5. DO NOT DRILL A HOLE LARGER THAN 4" IN DIAMETER IN ANY TJI. DO NOT DRILL ANY 4" IN DIAMETER HOLES ANY CLOSER THAN 4'-0" FROM ANY WALL SUPPORTING A TJI. 6. THE BOTTOM OF ALL WELDED PIPING WILL RUN LEVEL USING ECCENTRIC WELD REDUCERS AND ECCENTRICLY WELDED SHAPED NIPPLES. THE BOTTOM OF THE PIPING WILL BE AT 5" BOTTOM OF DECK. G -o'2 0 H 4 0 • ,IAO �TI BOD TI 0 T4 1' 7-10 1 f 342 I'z 1-5 f Z I14 I14 TI 10 , a-012 0 2 r I 4 -112. cc _+ 1 _cv IT I /17.� 7-4) ( z4 = it -1 a LL crt t V I- 1 _al / 1.1173► z - N T4, ill* u' TI =� 1 12 1 'L 1''= r t 11Z I' /C a II',_f� ' , al b ` `M ✓ N 8 -IL -1 �-10'c - 11-112 O-i.'c' I - t. -o c-1'� - lU-1'2 I--II-1 --I H k' L F T 1'4- 114 1 I' 4- I- 1 '4 1 14 1- I'4 1'r► r _ 11- C-O\� Q 11/ 11/ a 4/ 1 t 2-11'� .5-6'2 7-I'2 4-l0'2 7-8'Z 4-3'2 r m- L NI- - t- I'2. i N I'2 ' I'2 11-6 3-G ORANGE i'2 k 112 Io-�'z s -q2 rR T4 q-0 r J •112 112- 1 / 1 3-3 1-41 5-8 'o 2"P11'E CotJTUU.Il1ED On FIRST FLOOR PLP1J BELOW, 4-0 SECOND FLOOR SCALE: 1/8"=1'-0" - 4-O J LL 1178 TJI r LJ 1.22 .J 2X6X2338,(4E/-�) Ind NAILS, WITH 4" U -HOOK FOP; I'/lIFE, 5" LI --HOOK FOR I14"-2" i -'I€ _ . (2 EA) 4416X2" DFIV._ HANGER T3 1 0 0 IL H M lI , I/ 4-o 0-2'2 N C(1 123 i/2/T 4 32 82' -I 2 E (o-6)ul' ' 6-I 7 i'2 • t_.-iI-� rn 71 N tn it) 74 11 IZ- * ' 1 * T } l I21 +-Z� 10 II'L i -Q12 '2 j 1- 1 u-ii'z i-7 L E 1 �► I---14---: , 4- t- 1 r i.e. II 112 $1 III 3- 5'Z 0 0 CID 0 _If 0-G 4 tongs_ - l✓% M L 112 8-(0'2 4-0'2 3-9 m 6-6 1- t' I'2 7- j I'2 4-112 C 4 -7 1 m r 4 I. u_ , � o (1176TJI 2X6X18,(2EA)12X3B,N&W WITH 5" U- HOOKFOR I�-2��PIPE, 6 _U- HOOK FOR 2I 28.3,/ PIPE, HANGER Ti *178 TJI 4X6 X 2338, 4.EA) tI6d !JAILS 6" U- HOOK FOR 2121/8. 3 PI UE, (2 EA) 38X 212 LAGS. HANGER T2 11, 0 221 TII 3 1 st- BOJ I12 7. BLUE I/4 7-1'2 4-1012 \I t4,4 As INICI TI 033 4-- 4 HYDRAULICALLY MOST DEMANDING AREA: FIRST FLOOR -WET DENSITY: .15 GPM OVER 11500 SQUARE FEET SYSTEM DEMAND AT BOR:314.24 GPM AT 85. 41.: PSI (INCLUDING 0 GPM FOR INSIDE HOSE STREAMS) STAIRS AR & L L BOTH SIAIRs, NNEF‘5 8 RAILINGS., CONCRETE ENCASE t.D IN PORTLAND rit 43 • '-0" FIRST FLOOR RISER ROOM SEE SHEET I OF i 1F05. 1 HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND REVISIONS SYM MANUFACTURER TYPE MODEL HEAD FINISH WH IT E ESCUTCHEON FINISH ORFICE SIZE THREAD SIZE TEMP RATING QUANTITY LI HELE REL1/1 LE ELI AR LE LI A B LE r IF 11 F2 qv HITE Fif F./f2 WHIT f VVHITE 1Pc- Pot_ AFF BOB BOD BOJ BOP BOT CTS FO iFOw OFOw NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT OF SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO SPRINKLERS UNLESS NOTED OTHERWISE ELI ABLE CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE 4 -WAY EARTHQUAKE SWAY BRACE NO. DATE BY REASON FOR REVISION IST FLOOR FIELD CHEcK. CONTRACT WITH HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE TITAN CONSTRUCTION CO. 11061 NE 2ND STREET, SUITE 200 BELLEVUE, WA 98004 PHONE: (206) 454-8120 CONTACT: HAL SIGNETT PROJECT RELIABLE CFIRoHE 2 PC -CAR SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East Tacoma, WA 98424 CONTR. REG. NO. SMITHFS1360T HOMESTEAD VILLAGE 15635 WEST VALLEY HIWAY TUKWILA, WA TOTAL THIS SHEET DESIGNER SHEET POMMERT • JOB NO. R- 305 INSPECTORS TEST $ AUXILARY DRAIN 12"X 18"AccEsS PANEL "8Y 0 -THE BLDG. • •I IC ST . MAN ING REA: ATTIC DENSITY: . 15 GPM OVER 1.950 SQUARE FEET SYSTEM DEMAND AT BOR: GPM ATIO4,46PSI (INCLUDING 0 GPM FOR INSIDE HOSE STREAMS) • • 11t • -o 7-8 6 -6 g.. ,-0 v vim Pik -Nu Tom _b,ts. w�m.•0WA.ei 1;4F�mm.«�«�.���.�a�aMilL.. .��� 140 �►�..r�i. mss_— .-__,..;.s...0.-ate Lp.:1111111111111.6=111.100161111:410%1 0081011211~���"../MMINNI~U~Wilallgrig _ Via. RIDGE �\\\\\. \,\\\� — RIDGE • • 112 'STAGGER eifV RI•DGE \BELOW- \ ++ V h. �� ���� va�s4�� `' 112 1Z\\ • 112. • • • FREEZE PROTECTION: HEAT TAPE AND INSULATE 5'-6" LF OF PIPING THREE PLACES EACH ON FLOORS 1ST THRU 3RD. • • ATTIC FITTER / LISTER NOTES ( 3RD FLOOR & ATTIC ONLY ) 2. ALL HANGERS TO BE TS1 OR TS2 U.N.O. ( SEE DETAILS ON 3. HANGER SPACING TO BE AS FOLLOWS U.N.O. 4. DRY SYSTEM TO BE SLOPED PER NFPA 13 REQUIREMENTS. TIN STRAP 0 #8 x 1 1/4" WASHER HEAD SCREW JOIST/BOTTOM CHORD HANGER TS -I NTS a� /?/o6 aF is e TIN STRAP #8 x 1 1/4" WASHER HEAD SCREW \ BOTTOM CHORD/ JOIST WOOD HEADER HANGER 1 6D NAIL (4 PL) Ern 1. 41/ 7_, ! r_44_ 1 r g 1;im 11 I 14 7 1 0 Era it ED 11 6*--gt 6-6 8-8 Fall Saw 'Mlle WIMP vo al -Eljan---EELQ,5 it 0 [ _r_ _r tft 114 7-7 • 4 HANGER LEGEND ALL HANGER /-\ HE To BE vARtATIONS OF TS -1 T - HYDRAULICALLY MOST DEMANDING AREA: 3RD FLOO DENSITY: .1 5 GPM OVER 11500 SQUARE FEET SYSTEM DEMAND AT BOR:290.83GPM AT 66.3IPSI (INCLUDING 0 GPM FOR INSIDE HOSE STREAMS) SYM MANUFACTURER TYPE SPRINKLER LEGEND MODEL REL IFA • C IA HEAD FINISH ESCUTCHEON FINISH vv 4-11TE ORFICE SIZE THREAD SIZE TEMP RATING 2 la 1617 QUANTITY 70 <13 TOTAL THIS SHEET ABBREVIATIONS AFF BOB BOD BOJ SOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURL1N BOTTOM OF TRUSS CUT OF SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO SPRINKLERS UNLESS NOTED OTHERWISE SYMBOL LEGEND -0 CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE 4 -WAY EARTHQUAKE SWAY BRACE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE ra THIRD FLOOR REVISIONS NO. DATE BY REASON FOR REVISION r IT 24 r _Tr__ 9 • • NTS CONTRACT WITH TITAN CONSTRUCTION CO. 11061 NE 2ND STREET, SUITE 200 BELLEVUE, WA 98004 PHONE: (206) 454-8120 CONTACT: HAL SIGNETT ir5 SMITH F11I0R6E54StbYSAvTeE. ME S, INC. CON1R REG NO SkliT.EFG13607 PROJECT HOMESTEAD VILLAGE 15635 WEST VALLEY HIWAY TUKWILA, WA DESIGNER DATE SHEET JOB NO. PQMMERT F. O.5, e BULK FEEDS 114 WALL. WET c,.a G . Ct DRY RISER i DRY Bu Llt To ATTIC 0 VVET RISER'S 4 0 1 I ' O� 10. I 3 H rri 11 I M I 11 8 CvZ164 1 I-912 i RISER PLAN VIEW ITEM QTY. 1 3 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 3 - 3 3 3 3 1 1 1 1 1 1 1 0 2 4 SCALE 1/2"=1'-0" L(9 r a0 v,.o • (90 A a0 00 AO - �,o F 05 7 1W 1111 =1111 1111 ‘71 - 21�PI PE STAN D RISER DETAIL -110)11112 0 2 SCALE 1 /2"=1'-0" RISER EQUIPMENT 4 SIZE DESCRIPTION 3" BUTTERFLY VALVE WITH BUILT-IN SUPERVISORY SWITCH - 1 1 14" MAIN DRAIN 1/4" PRESSURE GAUGE ASSEMBLY 1/2" 3" 1" 10" 1/2" 4" 4" 1/2" 2" 600 GAL. PRESSURE RELIEF VALVE WATERFLOW INDICATOR INSPECTOR'S TEST VALVE ELECTRIC BELL DPV FILL LINE VALVE WAFER BUTTERFLY VALVE WITH BUILT-IN TAMPER DRY PIPE VALVE PRESSURE SWITCH HIGH / LOW PRESSURE SWITCH AIR MAINTENANCE DEVICE MAIN DRAIN AIR COMPRESSOR 13 MANUFACTURER GRUVLOK POTTER ELECTRIC POTTER ELECTRIC KENNEDY GEM POTTER ELECTRIC POTTER ELECTRIC GEM GAST 12 -HEAD SPARE HEAD CABINET CONTAINING THE FOLLOWING: 14 MODEL # GN7722-3FD VSR-F PBA 12010 93W1 F 3021 PS 10-A2 PS40-A2 F 324 6LCF-13-M616X SPARE SPRINKLERS & WRENCHES SPRINKLERS MANUFACTURER TYPE MODEL FINISH ORIFICE THREAD TEMP. QTY. RELIABLE SSU G BRONZE 12" 1/2" 165°F 1 RELIABLE SSU G BRONZE 1/2" 1/2" 212°F 2 RELIABLE SSP FIFR WHITE 1/2" 1/2" 155°F 2 RELIABLE SSP F1FR WHITE 1/2" 1/2" 200°F 1 RELIABLE REC-SSP F1FR/F2 WHITE 1/2" 1/2" 155°F 2 RELIABLE REC-SSP F1FR/F2 WHITW 17/32" 3/4" 155°F 2 RELIABLE HSW FIFR CHROME 1/2" 1/2" 155°F 1 RELIABLE HSW G BRONZE 1/2" 1/2" 165°F 1 WRENCHES RELIABLE MODEL D ' 1 GENERAL NOTES. 1. DISCHARGE MAIN DRAIN TO A SAFE LOCATION OUTSIDE / FLOOR DRAIN. 2. MAINTAIN A 2" ANNULAR SPACE AROUND PIPES PASSING THRU CONCRETE FLOORS. 3. ALL GROOVED COUPLINGS ARE RIGID UNLESS NOTED WITH A ( F) WHICH ARE FLEXIBLE. SYSTEM NO. 1 DRY ATTIC '1 AREA DESCRIPTION ATTIC AREA SQ. FOOTAGE 15,539 NUMBER OF SPRINKLERS 188 HYDRAULIC CALCULATION DATA DESIGN DENSITY: .10 GPM 6,150 SQ. FT ACTUAL DENSITY: .10 GPM / 2,076 SQ. FT. DEMAND AT BASE OF RISER 348.74 GPM AT 71.84 PSI (0 GPM INSIDE HOSE ALLOWANCE ) DEMAND AT CITY CONNECTION 448.74 GPM AT 80.41 PSI ( 100 GPM TOTAL HOSE ALLOWANCE ) DRY SYSTEM CAPACITY: 430 GALLONS. SYSTEM NO. 1 WET SYSTEM 1ST FLOOR AREA - AREA SQ. NUMBER OF DESCRIPTION FOOTAGE SPRINKLERS HOTEUMOTEL 15,538 116 • HYDRAULIC CALCULATION DATA DESIGN DENSITY: .16 GPM / 1,500 SQ. FT. ACTUAL DENSITY: .15 GPM / 1,508 SQ. FT. DEMAND AT BASE OF RISER 314.24 GPM AT 85.88 PSI ( 0 GPM INSIDE HOSE ALLOWANCE ) DEMAND AT CITY CONNECTION 564.24 GPM AT 94.63 PSI ( 260 GPM TOTAL HOSE ALLOWANCE ) SYSTEM NO. 3 WET SYSTEM 3RD FLOOR (2ND FLOOR SIMILAR) AREA DISCRIOTION HOTEL / MOTEL AREA SQ. FOOTAGE 15, 538 NUMBER OF SPRINKLERS 89 HYDRAULIC CALCULATION DATA DESIGN DENSITY: .15 GPM / 1,600 SQ. FT. ACTUAL DENSITY: .15 GPM / 1,593 SQ.FT. DEMAND AT BASE OF RISER 290.83 GPM AT 66.31 PSI ( 0 GPM INSIDE HOSE ALLOWANCE ) DEMAND AT CITY CONNECTION 540.83 GPM AT 74.74 PSI ( 250 GPM TOTAL HOSE ALLOWANCE ) • . • • • • • • 1 • • • UNDERGROUND NOTES: 1) ALL UNDERGROUND PIPNG PAST 5'-O OUTSIDE THE BUILDING TO BE BY OTHERS. CONTRACTOR TO BE STATE LICENSED AND CERTIFIED TO INSTALL UNDERGROUND PIPING PER WAC 212-80. 2) ALL UNDERGROUND PIPING SHALL HAVE 3' MINIMUM BURY (TO TOP OF PIPE). 3) ALL UNDERGROUND PIPING SHALL BE UL LISTED AND/OR FM APPROVED FOR FIRE PROTECTION. 4) ALL UNDERGROUND PIPING SHALL BE RODDED AND/OR BLOCKED IN ACCORDANCE WITH THE SPECIFICATIONS AND NFPA 24 (LATEST EDITION). 5) ALL UNDERGROUND PIPNG SHALL BE HYDRO- STATICALLY TESTED AT NOT LESS THAN 200 PSI OR 50 PSI ABOVE STATIC PRESSURE IN EXCESS OF 150 PSI FOR TWO HOURS IN ACCORDANCE WITH NFPA 24 (LATEST EDITION). 6) ALL UNDERGROUND PIPING SHALL BE FLUSHED IN ACCORDANCE WITH NFPA 24 (LATEST EDITION). FLOW THE REQURIED RATE UNTIL WATER IS CLEAR AS BNDICATED BY NO COLLECTION OF FOREIGN MATERIAL IN BURLAP BAGS AT OUTLETS. 4" - 390 GPM 6" - 880 GPM 8" - 1,560 GPM 10- - 2,400 GPM 12" - 3,520 GPM 7) ALL UNDERGROUND PIPNG SHALL BE STERILIZED PER LOCAL JURISDICTION REQUIREMENTS. SOUTHCENTER TUKWILA TO TACOMA VICINITY MAP WATER INFORMATION STATIC - RESIDUAL FLOWING ELEV. OF TEST LOCATION OF TEST HYDRANT EASTBOUND 1-405 OFFRAMP 147 PSI 100 PSI 1300 GPM SAME AS SITE #114 @ STRANDER GENERA_ L NOTES f- 1 1. ALL COUPLINGS WITH (F ) TO BE FLEXIBLE: 2. ALL PIPE TO BE AS FOLLOWS: STEEL PIPE ASTM A-795 OR BETTER PIPE SIZE SCHEDULE WALL THICKNESS INTERNAL DIAMETER - END PREP TYPES ALLOWED WUGNT OF WATER / PIPE CAPACITY M GALLONS 1 1 40 0.133 1.049 THREADED, CUT GROOVED, ROLL GROOVED, PLAIN END, POLISHED 2.063 8.844 1 1/4 SUPER-FLO 0.059 1.542 ROLL GROOVED, POLISHED, PLAIN END ( FOR BUTT WELDING) 1.817 8.887 1 1/2 SUPER-FLO 0.074 1.752 ROLL GROOVED, POLISHED, PLAIN END ( FOR BUTT WELDING) 2.4411 8.125 2 SUPER-FLO 0.074 2.227 ROLL GROOVED, POLISHED, PLAIN END ( FOR BUTT WELDING) 3.464 8.202 2 1/2 SUPER-FLO 0.074 2.727 ROLL GROOVED, PLAIN END ( FOR BUTT WELDING) 4.734 8.303 3 SUPER-FLO 0.074 3.362 ROLL GROOVED, PLAIN END ( FOR BUTT WELDING) 8.628 8.468 4 SUPER-FLO 0.074 4.352 ROLL GROOVED, PLAIN END ( FOR BUTT WELDING) 1.127 8.773 5 10 0.134 5.295 ROLL GROOVED, PLAIN END (FOR BUTT WELDING) 17.300 1.144 6 •• 0.134 6.357 ROU. GROOVED, PLAIN END (FOR BUTT WELDING) 23.030 1.141 8 •• 0.118 8.249 ROLL GROOVED, PLAIN END (FOR BUTT WELDING) 40.E 2.78 •• WALL THICKNESS PER NFPA B13 11 11 11 11 11 11 11 u 11 11 11 a 11 11 11 u n a 11 11 a 1• 11 11H 11 11 11 11 11 11 11 11 11 11 11 11 1 11 SMITH FIRE SYSTEMS 0 START POINT 5 =O~ .ou-r. RISER N \‘• � 1 41 • i FDC IN YARD p I IN YARD "BALK ftW U 1‘..KUN5 -7 N N 441 (1i7r 1k• 1 1 1 1 1 1 1 1 1 1 n 11 11 11 11 11 11 u 11 11 11 11 11 11 u 11 11 11 11 11 u 11 11 u u 1 11 ,t 1 u 11 11 11 11 1 1111 11 11 11 11 11 11 a 11 n 11 11 SCOPE OF WORK SMITH FIRE SYSTEMS (SFS) WILL PROVIDE A WET PIPE FIRE SPRINKLER SYSTEM TO PROTECT THE HEATED PORTIONS OF THE BUILDING. SEPARATE FLOOR CONTROLS WILL BE LOCATED IN THE FIRE SPRINKLER RISER ROOM LOCATED ON THE FIRST FLOOR. SFS WILL ALSO PROVIDE A I DRY PIPE FIRE SPRINKLER SYSTEM TO PROTECT THE UNHEATED ATTIC, WALKWAYS AND PORTE COCHERE. SFS WILL START 5'-0" OUTSIDE THE BUILDING. 1 CLAIRIFICATIONS 1 --- ALL AREAS ARE PROTECTED BY A WET SYSTEM AND MUST BE MAINTAINED AT A MINIMUM OF 40°F BY OTHERS TO PREVENT FREEZING. -- INSULATION CONTRACTOR TO PROVIDE TENTING OF ATTIC INSULATION OVER ALL WET SPRINKLER PIPING TO PROTECT THE SYSTEM FROM FREEZING. SFS ASSUMES THE STRUCTURE TO BE ADEQUATE TO SUPPORT THE SPRINKLER SYSTEM. SFS WILL PROVIDE FREEZE PROTECTION FOR THE WET SPRINKLER PIPING PASSING THROUGH THE UNHEATED CORRIDORS. - ALL WORK TO BE PERFORMED DURNING NORMAL WORKIING HOURS. EXCLUSIONS - (PAINTING OR LABELING OF SPRINKLER PIPING AND/OR EQUIPMENT. --- ELECTRICAL WIRING OF ANY KIND INCLUDING, BUT NOT LIMITED TO, ELECTRIC BELL, TAMPER SWITCHES, WATERFLOW SWITCHES AND AIR COMPRESSOR.. --- - -- CENTRAL STATION ALARM EQUIPMENT, WIRING AND MONITORING. --- ALL UNDERGROUND PIPING BEYOND 5'-0" OUT. SMALL HOSE STATIONS. DESIGN CRITERIA HOTEL'/MOTEL & SUPPORT AREAS: PER NFPA 13 , 1994 EDITION ORDINARY HAZARD: .15 GPM / 1,500 SQ.FT. GROUP 1 UNHEATED ATTIC: LIGHT HAZARD: • i /, a a a If 1 1 1 L i` 1111 2.;.* 1111111111111111111111111111j111��_ �11111111111_�_ _11 _ � � 1I1 ---+ 0 111 r JE- •r, .•ILLI 811 - • • • • • • SITE PLAN SCALE: 1/20" = 1-0" 11 11 1, 11 u 11 11 f1 11 11 11 11 11 1 11 11 11 11 11 n u 11 u u n TUKWILA FIRE DEPARTM A Please call: 575-4407. and give this job No. q-1 S teak and exact address for shut• down or restoration approval. PER NFPA 13 , 1994 EDITION .10 GPM / 1,950 SQ.FT. ACCPTED .„. Wito'er C rn!nerts M Plate•: .rt Rid Fcr TIE Attar :.1 tetter SVT r. T'jieN'la F:re 911. city ._ :l 1C' n ``i f7-. `_ '�i �': iif •mit 'ir.^.1 a.iiepfallce iz ?u jr;'.i- ti: 'Ti,"..' :r-- t.l--V 111'v;..t.,,l... J- 1 he Tukwila Fire Frevent'ol. F.J .I : ;,i. Date: - 1 7-0V-1 By' Sts FILE • 1• HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SYM MANUFACTURER TYPE MODEL RELIABLE 55 U FI FR HEAD FINISH 1 BRoNIE ESCUTCHEON FINISH ORFICE SIZE 12 THREAD SIZE TEMP RATING I(.25 QUANTITY TOTAL THIS SHEET AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT OF SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO SPRINKLERS UNLESS NOTED OTHERWISE -o 0 SYMBOL LEGEND CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE 4 -WAY EARTHQUAKE SWAY BRACE REVISIONS HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE NO. DATE BY REASON FOR REVISION CONTRACT WITH TITAN CONSTRUCTION CO. 11061 NE 2ND STREET, SUITE 200 BELLEVUE, WA 98004 PHONE: (206) 454 -8120 - FAX.: (206) 451-0380 CONTACT: HAL SIGNETT SITE: MIKE WINNE (206)-204-1427 Ax (206)-204-1426 PAGER (206)-996-8551 S SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East Tacoma, WA 98424 CONTR. REG. NO. SMITHFS1360T Ph: (206) 926-1880 • Fax: (206) 926-2350 PROJECT HOMESTEAD VILLAGE 15635 WEST VALLEY HIWAY _- TUKWILA, WA JUN 16 ti DESIGNER DATE SHEET JOB NO. POMMERT 6- 9 - 97 1 OF 3 _ R305 pao istems, Inc sAf, .,4\ 5 `e Cei.rt�i care r �a o r4 m $ r I. 1 111 IF25-11 til. MA.1 ,, AulIIlb, iA-57 SS ect on s.riAk cl filr'ugh Deceltac- WitWihit6i1 �tirvejiing ?a i`rig 'uta PLAN REVIEWED AS NOTEb SEATTLE WASH. • ct ccxriments and'ac�epfances relate ekclasivePyto.elatiiin'effect Various coni ifiods;upon:fire'insprancg taus. They are,npt to be co- 6trued as bearing "in arty way upon the que9tion bt .i iettier.'`due care' hes been exerc+ied with respect to possible.liabili;y fgR�c pefsonaj (h- ifrary Or damage to"property..tt tS rrr6�nfied thbt `Iir312? Wfitci! i M *mitt Fra .i4 Vitt oral.c. PROJECT SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East ig Tacoma, WA 98424 CONTR. REG. NO. SMITHFS1360T Ph: (206) 926-1880 • Fax: (206) 926-2350 HOMESTEAD VILLAGE 15635 WEST VALLEY HIWAY TUKWILA, WA DESIGNER POMMERT DATE 6 - 9 —97 1J SHEET 1 JOB NO. 2 OF 3 1 R— 305 6-012 0 1. N M O N f1 • —� T -414 , 114 L J OF.o.S, 1 Eo /1" 7 // z4. 0 - t • 178 TJ I 0 0 0 FREEZE PROTECTION: HEAT TAPE AND INSULATE 5'-6" LF OF PIPING THREE PLACES EACH ON FLOORS 1ST THRU 3RD. 9 QC - r 2X6X18,(2.EA)12X3B,N&W WITH 5 U-HOOKFORI-2 PIPE, 6 _U- HOOK FOR 2I 2 &3„ PIPE, 2"PIPE cotJT11.1UED oN FIRST FLOOR PLAN BELOW, HANGER TI r 1 0-10 SECOND FLOOR SCALE: 1/8"=1'-0" FITTER / LISTER NOTES (1ST & 2ND FLOOR ONLY ) 1. ALL DROPS TO BE 1 X O'-10 1/2” TT U.N.O. 2. ALL HANGERS TO BE T1 OR T2 U.N.O. (SEE DETAIL SHEET 2 OF 2 ). 3. HANGER SPACING TO BE AS FOLLOWS U.N.O. 1 1/4" AND LESS : 12'-0" O.C. MAXIMUM. 1 1/2" AND GREATER : 15'-0" O.0 MAXIMUM. I I/ 4 -O f111Ma O u. FREEZE PROTECTION: HEAT TAPE AND INSULATE 5'-6" LF OF PIPING THREE PLACES EACH ON FLOORS 1ST THRU 3RD. - 2,4 9 eV a en '_ 1 N , a -r.F.O.S. 1.F.0.5. A 410. '4 ;14 5 TJl 2-0 I'4 I -2'L 41s T I5 -O 1 , N r: 4- _ 12-o'z h 1 m 114 11-6 1'4 v _s. Io N r I. 8E I'2 ±5-2 12-7 12-1 12-1 1 -0 I-7, �I 1 -s- j \.0-� tI' n \QI,L, 1-a cr5 7-2 o -FI 2.4" O.G. ELF1V. EQU I P 1---r–. L_. -4 F1 - N E L E V. , Tr- 12"TJL z4„O.c. 114 114 12 a 1 o o 1 1'4- -T r 2-7 '_ r_T r 9- L_1 .I 1 1 ' 0 11= soca-Lc-4 CD ;I ♦.t 1 51"i v I S11 ei II __ 7 _ 519 N � "4. '519 — N 0- t 1 N T kti .�K�o i+ u: t/�0212 1'4 R-11 t 9 — .4- 8-1 8-4 I'+ 13-1 I'4 a 12= 1'2 OilN 7-11.i. N O T� 2 .w •✓ 1 r1 III i� I III i ♦1 L FNS -* Nt J�==.• 0001- ,. Y^ -lik 61 :Lr:-: :2 1 l'i iM_-1; I .1; IT -,i ILI I"-, 4 I 1 ,S L—J r 1 1 F -I L` N H-3 -3 s;) 0 HYDRAULICALLY MOST DEMANDING AREA: F I RST F L 00 R -WE T DENSITY: .15 GPM OVER 15500 SQUARE FEET SYSTEM DEMAND AT BOR: 314.24 GPM AT85.:`: PSI (INCLUDING 0 GPM FOR INSIDE HOSE STREAMS) HANGER LEGEND SYM MANUFACTURER TYPE - TYPICA BOTH STAIRS, STAII-1S ARE CONCRETE TREADS METAL RUNNERS 8 RAILINGS1 CONCRETE DECKING OVEP, wool) SUBSTRUCTURE &W1►LLS ENCASED IN PORTLAND CEMENT PLASTER SYSTEM, SPRINKLER LEGEND MODEL HEAD FINISH ESCUTCHEON FINISH ORFICE SIZE THREAD SIZE TEMP RATING i /4? 40-11-- i'4 4r- 1--I'4 `s 2=1- i 11,4 O N th » rJ/ aD 24`0 - QUANTITY P ELI ABLE SSP FI F R WH I TE 2t"C-WHT 12 12 1ST 32. O RELI MBLE R EC -S S P RELIABLE R EC -SSP FIFR/FZ WHITE WHITE - 12 1-) C VVHITf WHITE REL; E LE CHROME a <0 ELI AR LE HS vV BRoNzE 2 Pc -FOL 165 RELIABLE Gi CH ROME IC 71 RELIABLE G3 0 ELI A BLE SSU PI FR P‘ ELIABLE SSP 2 200 TOTAL THIS SHEET ABBREVIATIONS AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURL1N BOTTOM OF TRUSS CUT OF SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO SPRINKLERS UNLESS NOTED OTHERWISE IF4"LINES CUNrINur O1.1 QN 2ND FLOOD PLAN ABOVE. SYMBOL LEGEND CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE 4 -WAY EARTHQUAKE SWAY BRACE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE NO. DATE +t` BY REVISIONS REASON FOR REVISION FIRST FLOOR SCALE: 1/8"=1'-0" CONTRACT WITH TITAN CONSTRUCTION CO. 11061 NE 2ND STREET, SUITE 200 BELLEVUE, WA 98004 PHONE: (206) 454-8120 ' CONTACT: HAL SIGNETT a 1178 TJI u 4X6 X 2338, (4.EA) 416 d NAILS WITH 5-U- HOOK FOR 1/,/ 2 PIPE, 61U- HOOK FOR 212/t. 3 PI PE, (2 EA) 8 X 212 LAGS. HANGER T2 RISER ROOM SEE SHEET 10F .51-5” SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East Tacoma, WA 98424 CONTR. REG. NO. SMITHES1360T Ph: (206) 926-1880 • Fax: (206) 926-2350 PROJECT HOMESTEAD VILLAGE 15635 WEST VALLEY HIWAY TUKWILA, WA DESIGNER DATE SHEET JOB NO. POMMERT R- 305 • • LL WflthSurvepig & Ra6tg ur PLAN REVIEWED AS NOTED SEATTLE ,:t4ASHM . corrimerts atql iiC'cptinces relate e'xclusi4ell o rolatAiie eitee't ‘terious conditions tire insOrance rate.. They ere rot to be Orued hirrinf, in Anif.`waiy upon the questing ol ther "doe Car'e" 'hes boon exercised with ic:svect topussitl'e abiit tor personal Ivry of rtimae to opert'i It 1S rrfl?fl7 ,J r7 1.4..0, IA 401 SMITH FIRE SYSTEMS, INC. 1106 54th Ave. E. Tacoma, WA 98424 CONTR REG NO SMiTHFS1350T Ph: (206) 926-1880 Fax: (206) 926-2350 PROJECT HOMESTEAD VILLAGE 15635 WEST VALLEY HIWAY TUKWILA, WA DESIGNER POMMERT DATE SHEET JOB NO. 9-97 3 CIF 3 R-305 INSPECTORS TEST & AUXILARY DRAIN 12" X 18"A ccESS PA IN E L 'IB Y OTHERS i BLDG• I/ HYDRAULICALLY MOST DEMANDING AREA: ATTIC DENSITY: .10 GPM OVER 1 ` 1 SQUARE FEET SYSTEM DEMAND AT BOR: A • AT 71.84 PSI (INCLUDING 0 GPM FOR INSIDE HOSE STREAMS) • • • -o 7-8 , A. 4 -4 /-o ►+� �Ih\ G -o 8-o 0 P IMN2,11t ,4'41; \ismer einsmossi.w anosi\lirAM.smos +_ 4 RIDGE Ii, l\Cry ii:l • ■I7s� 1 \ SOI/` \ ►Tlf (i� l'4 FREEZE PROTECTION: HEAT TAPE AND INSULATE 5'-6" LF OF PIPING THREE PLACES EACH ON FLOORS 1ST THRU 3RD. • 1• • LJ ATTIC SCALE: 1/8"=1'-0" FITTER / LISTER NOTES ( 3RD FLOOR & ATTIC ONLY ) 1. ALL DROPS TO BE 1 X 0'-8" TT C -FC U.N.O. 2. ALL HANGERS TO BE TS1 OR TS2 U.N.O. ( SEE DETAILS ON SHEET 3 OF 3 I. 3. HANGER SPACING TO BE AS FOLLOWS U.N.O. 1 1/4" AND LESS : 12'-0" O.C. MAXIMUM. 1 1/2" AND GREATER : 15'-0" O.0 MAXIMUM. 4. DRY SYSTEM TO BE SLOPED PER NFPA 13 REQUIREMENTS. --'---t— - T ` I I' L !' 4 TIN STRAP #8 x 1 1/4" WASHER HEAD SCREW JOIST/BOTTOM CHORD HANGER TS -I 1 NTS • • L -C) 0 / 1I4 .S-0 7-7 4: -9 0 1 rr- /- -' TIN STRAP or Rto6 #8 x 1 1/4" WASHER HEAD SCREW BOTTOM CHORD/ JOIST WOOD HEADER 1 6D NAIL (4 PL) HANGER TS -2 NTS T 114 42-3! I1 r 4- t it 1'4 / 6-7 ry K L—_ 9-s 2-7 1.5"--1 -- J s=8 04 // OW 2- 114 -i? - o ®�-0 7-7 tr �--,- `.' e HYDRAULICALLY MOST DEMANDING AREA: 3RD FLOOR DENSITY: .15 GPM OVER I 5 SQUARE FEET SYSTEM DEMAND AT BOR: GPM AT F..31 PSI (INCLUDING 0 GPM FOR INSIDE HOSE STREAMS) 4 e THIRD FLOOR SCALE: 118"=1'-0" 4 -S 24-- — 8- - /0 8-9 114 • HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND REVISIONS ALL HANGER, ARE TO BE VARIATIONS OF TS—I OR Ts —c . SYM MANUFACTURER TYPE 1 MODEL k L 1 ABLE 55u 1 G HEAD FINISH ESCUTCHEON FINISH LRON1E ORFICE SIZE I THREAD SIZE 2- TEMP RATING 2 12 QUANTITY 1 4- s REL IA ELF kEC—syr 1 FI FR/HZ WHITE VV 1 T E 12 IZ I 5 5 70 RELIABLE IRC -55P FIFE;/rZ WHITE HtLI/\tiLE U . 1=. - rHROME VV HITS CH ROME I -132 34, 155 fN 2 165 45 KELI/4BLE H 5 VV G bRC) NZE 1_ 14 l ip 5 • TOTAL THIS SHEET 7 7 AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT OF SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO SPRINKLERS UNLESS NOTED OTHERWISE -0 O CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE 4 -WAY EARTHQUAKE SWAY BRACE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE NO. DATE BY REASON FOR REVISION CONTRACT WITH TITAN CONSTRUCTION CO. 11061 NE 2ND STREET, SUITE 200 BELLEVUE, WA 98004 PHONE: (206) 454-8120 FAX.: (206) 451-0380 CONTACT: HAL S GNETT SMITH FIRE SYSTEMS, INC. 1106 54th Ave. E. Tacoma, WA 98424 CONTR REG NO SMITHFS1360T Ph: (206) 926-1880 Fax: (206) 926-2350 PROJECT HOMESTEAD VILLAGE 15635 WEST VALLEY HIWAY TUKWILA, WA DESIGNER DATE SHEET JOB NO. POMMERT 6-9-97 3 OF 3 R-305