Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 15037 TUKWILA INTERNATIONAL BLVD - TACO TIME - PERMITS AND PLANS
15037 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS 11-S-240 11-H-268 11-F-229 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 15037 TUKLi i t A 1NC7E,V (AT(04AL (it it!) Site Address: Suite Number: Tenant Name: TiVo T(I)1E Property Owner's Name: Floor: 1 New Tenant? ❑ - Yes XI- No Mailing Address: City State Zip CONTACT PERSON-ifrthere are questions/about the submittal. Name: (1 At K -�^Cf �V L ZE Company Name: W L V LICA- Fi ('rE I G Day Telephone: 20 6- 232— es -c1 Mailing Address: 1534 F(er 1 AVE S se -A-71'11_6 UA q8(31- E-mail Address: 6((1 He C�DL0/iB(AF(REsC14ErFaxNumber: 26G-348 roc, Valuation of Project (contractor's bid price): $ li5; 04 0 Scope of Work (please provide detailed information): He L) Ft (C SP/?(t1 /<1.6? -SyS 2 r PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: -- /t Aviv ,2,d1.:e , Date: to—lo-1( Print Name: U a ( AM &G 1 UL ZE Day Telephone: 2a)-2.32-83-‘ Plan Permit App.doc 5/14/10 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Taco Time 15037 Tukwila International BI Permit No.: 11-S-240 Date: October 26, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Taco Time 15037 Tukwila International BI 11-H-268 December 5, 2011 Permit No.: Date: Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Nozzle heights above appliances to be per manufacturers installation guidelines. • Fryers shall be installed with at least a 16 inch space between the fryer and surface flames from adjacent cooking equipment or a minimum 8 inch high steel or tempered glass baffle plate shall be installed between the appliances. • Upon activaton of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust system whenever cooking operations occur. The activation of the exhaust system shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. • The suppression system manual pull station shall be located no closer than 10 ft. and no farther than 20 ft. from the cooking equipment and be placed at a height of 42 to 48 inches above the floor. • The inside lower edge of the hood shall overhang or extend a horizontal distance of not less than 6 inches beyond the edge of the top horizontal surface of the appliance on all open sides. The vertical distance between the front lower lip of the hood and such surface shall not exceed 4 feet. • If cooking appliances are wheeled, the appliance wheels shall be set in tracks permanently mounted to the floor to ensure appliance is returned to original location if moved for cleaning or maintenance. FIRE PROTECTION, INC. PO BOX 12642 MILL CBEEK, WA 91012 [4251 290-9600 OB 1-100-611-1125 FAX [4251353-4546 October 3, 2011 City of Tukwila -PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed plans for FIRE ALARM SYSTEM. The system has been designed per NFPA 72, 2007 edition requirements as well as WAC, IBC, IFC 2009, NEC current and your additional requirements. The building is fully -sprinkled. The system shall monitor by zone activation as well as separate trouble signals. Monitoring shall be provided via UL listed Central Station, The Alarm Center LACEY, WA., over 2 analog lines via a built in DACT. Audibility shall be in compliance with NFPA standards with a outdoor horn/strobe located on the outside of the building in the top 25% with a 95 candela strobe facing the first in -coming FIRE DEPARTMENT vehicles for easy building location. Interior DB shall be 75 DB minimum throughout. A full service and monitoring agreement is in force for the proper service and maintenance per NFPA requirements. All systems shall be UL certificated and placard. A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. 1730 Gibson Rd. Everett, WA 98204 WSCL# FIREPI*021ML UL CERT #608242-002 JOB SITE ADDRESS Taco Time 15037 International BLVD. Tukwila, WA. APPROVED UL MONITORING COMPANY Alarm Center, Inc./FPI 4300 3rd Ave. SE Lacey, WA 800-429-0991 UL CERT #902799-02 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring; Service; Testing; Runner Serv; Fire Protection, Inc. UL Cert; Fire Protection, Inc. AMBIENT TEMPERATURES No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AMBIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per UBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify UL listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re -dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, (no notification circuits shall activate.) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds. Low air shall activate at 251bs, causing for a supervisory signal. A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause alarm. Shorts on PIV, tamper and Hi -low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal. Should you have any further questions, please feel free to contact me directly. Robert Vaughn Project Manager **NICET-3 #115522**SFD #SCPV-04243 CITY OF REDMOND DESIGNER OF RECORD #10-B-113 12VDC 7Ah BACK-UP BATTERIES TO BE USED Global Project Values: SILENT '0 Project Name: Taco Time Standby Hours: 24 KNIGI- T . 'Project ID:I Alarm Mins 5 I PretparedBy_IRobert Vaughn ,Derating Factor 1.2 5700 Calculations ' -.61te;I10l3/2011 I ! Voltage,Drop VUaming Version 0224.09 ` ' •' 'Threshold_%: 10 Panel ID: 15700 I . Model: - 5700.Add. Fire Alarm Control Panel Max MAC Current:. 2:5 Amps Location: Sprinkler Room Volts: 24 VDC - - MaxPanelCurrent: 2.5 Amps `< ' •.. Ckt.# Circuit Name 4:14,-,,Current Draw .: ,'.-.Wire AWG'' ' "•Ohms Per . Length(ft) -.Actual Volts @ • %Drop • ;Stanby . Alarm --,'8, Type '!. •:, _1000 Ft.; ,:One-Way -. Ohms • EOL •. , 5700 5700 CTRL Panel 1 0.200 0.325 ". F •. - SD500-AIM Addr. Input Mod 0.000 0.000 SD500-MIM Mini-Input Module 5 0.003 J 0.003 SD500-ARM Addr. Relay Module 0.000 0.000 SD500-PS • Addr. Pull Station '::- 0.002 0.002 SD505-AIS Addr. Ion Smoke Det - 0.000 0.000 SD505-AHS Addr. Heat Detector ' 0.000 0.000 SD505-APS Addr. Photo Smoke Det 1 . 0.001 0.001 SD505-DUCTR Addr. Duct w/Relay 0.000 0.000 SD505-DUCT Addr. Duct 0.000 0.000 SD500-ANM Addr. Notification Module 0.000 0.000 SD500-LED Addr. LED Module : 0.000 0.000 SD500-SDM Addr. Smoke Det. Mod. 0.000 0.000 SD505-6R6 Addr. Det. Relay Base 0.000 0.000 SD505-6SB Addr. Det. Sounder Base 0.000 0.000. SD505-61B Addr. Det. Isolator Base 0.000 0.000 SD500-LIM Line Isolation Module 0.000 0.000 5860 • LCD Remote Annunc 0.000 0.000 5824 SeriaUParallel Module 0.000 0.000 _ 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 0.000 ' 5880 LED Driver Module 0.000 0.000 5883 Relay Module . 0.000 0.000 NAC #1 . SIG #1 0.000 1.086 #16 Solid - ." -.4.02 185 1.49 • 18.78 7.92% NAC #2 Not Used 0.000 0.000 #16 Solid 4.02 0.00 20.40 - 0.00% -Total Standby Current(Amps) 0.205 1.416 Total Alarm Current (Amps) ", •, . Standby Time In Hours '• 24 ' - • 0.083 Alarm Time In Minutes / 60 , (5 Mins) Total Standby AH Required ' -4.919 t 0.118 , Total Alarm AH Required Total Combined AH Required - 5.04 Command Shortcuts Multiply By The Derating Factor ,. - 1.20 Minimum BatteryAmpHours Required '-.- 6.04 Configure Circuits Print Page 12VDC 7Ah BACK-UP BATTERIES TO BE USED Size and Type of Pipe ToI-Brace Seismic Calculations Columbia Fire, Inc. Project Address: Taco Time 1 ,.. 1534 First Ave S Seattle, WA 98134 15037 Tukwila International BLVD 206.232.8569 Tukwila, WA COLUMFI952MG Job # S1106134 Calculations based on 2007 NFPA Pamphlet #13 1" Sch.40 Steel Pipe (25.4 mm) 43 lbs (20 kg) of Ud t ` Brace Information 44 lbs (20 kg) Tolco Brace Components Maximum Spacing 42',0" (12.8 m) Maximum Brace Length 7' 0" (2.14 m) Bracing Material 1" Sch.40 Angle from Vertical 450 Min. Least Rad. of Gyration 0.421" (11 mm) UR Value 200 Max Horizontal Load 1735 lbs (787 kg) Force Factor (Cp) 0.5 47 lbs (21 kg) Tolco Component Fig. Number Adjusted Load Fig.1000 Clamp 1425 lbs (646 kg) Fig.909 No -Thread Swivel 1425 lbs (646 kg) 'Calculation Based on CONCENTRIC Loading `Please Note: These calculations are for Tolco components only. Use of any other components voids these calculations and the listing of the assembly. Assembly TOLCO NO -THREAD SWAY BRACE LATERAL TOLCO FIG. 1000 FAST CLAMP ATTACHMENT STEEL Detail FIG. 909 SWIVEL PIPE BRACE 15% 29 lbs (13.15 kg) ,►° Fastener Information Fastener Orientation Type Diameter Length Maximum Load NFPA Type B Through, Bolt 1/2in. (13 mm) 3-1/2in. (89 mm) 250 lbs (113 kg) Brace Identification on Plans Lateral #1 Orientation of Brace Lateral Braced Pipe: 1" Sch.40 Steel Pipe Load Information Size and Type of Pipe Total Length Total Calculated Load 1" Sch.40 Steel Pipe (25.4 mm) 42ft (12.8 m) 43 lbs (20 kg) 2.5" Sch.10 Steel Pipe (63.5 mm) 15ft (4.6 m) 44 lbs (20 kg) 1.5" Sch.40 Steel Pipe (38.1 mm) 26ft (7.9 m) 47 lbs (21 kg) 1.25" Sch.40 Steel Pipe (31.75 mm) 42ft (12.8 m) 62 lbs (28 kg) Percentage added for Fittings and Sprinklers 15% 29 lbs (13.15 kg) Total Adjusted Load of all pipe within Zone of Influence 225 lbs (102 kg) lTol-Brace Version 71 Tol-Brace Seismic Calculations Taco Time 15037 Tukwila International BLVD Brace Identification Brace Type (Per NFPA#13) Braced Pipe Spacing of Brace Orientation of Brace Bracing Material Maximum Brace Length Slenderness Ratio used for Load Calculation True Angle of Brace for Calculation Type of Fastener Length of Fastener Job # S1106134 ®T'OLCO a marl of MB= Lateral #1 NFPA Type B 1" Sch.40 Steel Pipe 42' 0" (12.8 m) Lateral 1" Sch.40 7' 0" (2.14 m) 200 45° 1/2 x 3-1/2 (13 x 89 mm) Through -Bolt 3-1/2in. (89 mm) Summary of Pipe within Zone of Influence 1" Sch.40 Steel Pipe (25.4 mm) 42ft (12.8 m) 2.5" Sch.10 Steel Pipe (63.5 mm) 15ft (4.6 m) 1.5" Sch.40 Steel Pipe (38.1 mm) 26ft (7.9 m) 1.25" Sch.40 Steel Pipe (31.75 mm) 42ft (12.8 m) Allowance for Heads and Fittings Conclusions Total Adjusted Load of Pipe in Zone of Influence 225 lbs (102 kg) Material Capacity 1735 lbs (787 kg) Fastener Capacity 250 lbs (113 kg) Fig.1000 Clamp 1425 lbs (646 kg) Fig.909 No -Thread Swivel 1425 lbs (646 kg) Structural Member TJI and Wood block 15% Calculations prepared by Brian Schulze *The description of the Structual Member is for informational purposes only. Tol-Brace software calculates the brace assembly only, not the structure it is attached to. Calculated with Tol-Brace 7 visit us at www.tolco.com ZURN compan b4�,I,35Oi Double"Check DetectorAssembfy (with OS&Y gates) FEATURES Sizes: ❑ 2 1/2"* ❑ 3"* ❑ 4" ❑ 6" ❑ 8" 010" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 Class 125 *2 1/2" & 3" sizes use 4" body & reducer couplings OPTIONS (Suffixes can be combined) ❑ - with flanged end OS & Y gate valves (standard) ❑ L - less shut-off valves (grooved body connections) ❑ LM - less water meter ❑ - with remote reading meter ❑ - with gpm meter (standard) ❑ - with cu ft/min meter ❑ G - with grooved end OS&Y gate valves ❑ FG - with flanged inlet gate connection and grooved outlet gate connection ❑ PI - with Post Indicator Gate Valves (4"-10") DBGVIC - with grooved end butterfly valves ACCESSORIES ❑ Repair kit (rubber only) ❑ Thermal expansion tank (Model XT) ❑ OS & Y Gate valve tamper switch (OSY-40) ❑ Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) (with BGVIC valves) MODEL 350ADA SIZE in. mm WEIGHT WITHOUT GATES lbs. kg WITH GATES lbs. OS&Y (GXF) kg WITH GATES lbs. OS&Y (GXG) kg WITH BUTTERFLY VALVES lbs. (GXG) kg 2 1/2 65 105 47.5 207 94 199 90.3 123.8 56.2 3 80 104 47 224 101.5 214 97 124.4 56.5 4 100 91 41.3 245 111 219 99.4 123 55.8 6 150 141 64 377 171 347 158 193 87 6 8 200 302 137 778 353.2 754 342.3 410 186 10 250 355 161 1040 472.7 918 416.5 527 239 3 APPLICATION Designed for installation on potable water lines connections in fire sprinkler systems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Model 350ADA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. STANDARDS COMPLIANCE (HORIZONTAL & VERTICAL) • ASSE® Listed 1048 • AWWA Compliant C510 (with gates only) • CSA® Certified (4" - 8") • UL® Classified • C -UL® Classified • FM® Approved • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California • NYC MEA 221-04M-2 (2 1/2" - 8") MATERIALS Main valve body Access covers Coatings Internals Fasteners & springs Elastomers Polymers MODEL 350ADA with OS&Y option MODEL 350ADA with BGVIC option Ductile Iron ASTM A 536 Grade 4 Ductile Iron ASTM A 536 Grade 4 FDA Approved electrostatic epoxy finish Stainless steel, 300 Series NORYLTA9, NSF Listed Stainless Steel, 300 Series EPDM (FDA approved) Buna Nitrile (FDA approved) NORYLTM, NSF Listed MODEL 350 SIZE in ADA mm DIMENSION (approximate) A in mm A WITH BUTTERFLY VALVES in mm B LESS GATE VALVES in mm C in mm D in mm E OS&Y in OPEN mm E OS&Y CLOSED in mm E WITH BUTTERFLY VALVES in mm F in rnm G in mm 2 1/2 65 35 1/8 892 32 1/8 816 20 1/8 511 4 1/2 114 9 229 16 3/8 416 13 7/8 352 8 203 6 152 71/4 184 3 80 36 1/8 918 33 838 20 1/8 511 4 1/2 114 9 229 18 7/8 479 15 5/8 397 8 203 6 152 7 1/4 184 4 100 38 1/4 972 33 1/4 845 19 7/8 505 4 1/2 114 9 229 22 3/4 578 18 1/4 464 9 1/8 232 6 152 8 203 6 150 47 1/4 1200 40 1/4 1022 25 7/8 657 5 1/2 140 101/2 267 30 1/8 765 23 3/4 603 10 1/8 257 7 178 10 254 8 200 62 1575 55 1397 38 1/2 978 10 254 12 305 37 3/4 959 29 1/4 743 11 15/16 303 8 1/2 216 11 279 10 250 64 518 1642 58 1/2 1485 38 1/2 978 10 254 12 305 45 3/4 1162 35 3/8 899 13 5/16 338 81/2 216 12 305 Page 1 of 2 Attention: Model 350ADA (grooved body) and Model 350DA (flange body) have different lay lengths. REVISION BF-350ADA; 1111 J W re ti 5 enw a 0 Ir 0.0 12.6 FLOW CHARACTERISTICS MODEL 350ADA 2 1/2", 3" & 4" (STANDARD & METRIC) FLOW RATES (Us) 25.2 37.9 50.5 104 2 112" (65mm -0. 3" (80mm) 4" (100mm 0 200 63.1 1000 400 FLOW RATES (GPM) MODEL 350ADA 6", 8" & 10" (STANDARD & METRIC) 6 (150mm) FLOW RATES (Ns) 126.2 8 (200mm) 2000 FLOW RATES (GPM) O Rated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. DIRECTION OF FLOW = 1E111=1 0 _ 111= "II- IHE11Fy MODEL 350ADABGVIC (VERTICAL INSTALLATION) SPECIFICATIONS The Double Check Detector Backflow Prevention Assembly shall be ASSE® Listed 1048, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NoryITM (NSF Listed), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Prevention Assembly shall be a WILKINS Model 350ADA, 600 189.3 10" (250mm) 3000 800 cn 69 0 ce 35 cn co 0 a 252.4 104 69 co 0 W 35 0 w 0 0- 4000 4000 Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10ft/sec 15 ft/sec 2 1/2" 75 112 149 224 3" 115 173 230 346 4" 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 PROTECTIVE ENCLOSURE 12' MIN. 30" MAX. c as ��yv)1 DIRECTION OF FLOW 4> MODEL 350ADA (OUTDOOR INSTALLATION) WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1 -877 -BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com Page 2of2 se QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION The Globe Quick Response GL Series Dry Type Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Globe Quick Response GL Series Dry Type Pendent Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation ap- proximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, waterflows through the sprinkler and is distributed by the deflector in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Model GL Series sprinkler proven actu- ating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. SURFACE MOUNT SLEEVE & SKIRT TECHNICAL DATA y • See reverse side for Approvals and Specifications. • Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) • Water Working Pressure Rating - 175. psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze • Deflector - brass • Screw - brass • Bulb EXTENDED seat - brass •Spring - teflon coated nickel alloy • Retainer - brass • Pin - stainless steel •Torsion spring - stainless steel • Bulb - glass with alcohol based solution, 3mm • Orifice insert - brass • 3/4" NPT or 1" NPT • Outer tube - galvanized steel pipe • Inner tube stainless steel • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COL RECESSED CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES BULB COLOR N.F.IP.A. MAXIMUM CEILING TEMPERATURE ORDINARY s".;"IS5"i 5°P .:. : IQ °C ... INTERMEDIATE : 1 F `C ¢C HIGH r41:, ORANGE/RED YELLOW/GREEN BLUE .... .,.. ",... 25. (iC,. JUNE 2009 A-55 989-846-4583 is FAX 989-846-9231 BULLETIN GL5635, REV.#12 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE NOMINAL "K" FACTOR ` THREAD SIZE LENGTH 1 RNISHES 5.6 (80 metric) 175°F 79°C 3/4" or 1" NPT cULus Variable to 48" FM Va3riiable to Factory Bronze Satin Chrome' Bright Chrome White Polyester Black Polyester Lead Coated' 8.1 (116 metric) NYC DOB MEA 101-92-E 1" NPT NOTE METRIC CANVFRSIMJc ADC e000nvi..nrc 5.6 5.6 8.1 1" NPT 3/4" NPT 1"NPT cULus LISTED CORROSION RESISTANT: POLYESTER MUST BE SPECIFIED ON ORDER. FINISHES AVAILABLE ON SPECIAL ORDER. 2LEAD COATED IS UL APPROVED ONLY. STYLE 135°F 57°C 155°F 68"C 175°F 79°C 200°F 93"C 288°F 141°C Illus NYC DOB MEA 101-92-E PBCB4T GL5635 GL5636 GL8135 5.6 5.6 8.1 1" NPT 3/4" NPT 1"NPT X X X X X X X X X X X X X - X X X X X X X - X X RECESSED PBOF NOTE: LISTED FOR GL5635 GL5636 GL8135 ALL HA7ARfR 5.6 5.6 8.1 1' NPT 3/4" NPT 1"NPT X X X X X X X X X X X X X - X X X X X X X - X X "PENDENT STYLE - FM APPROVED 155°F, 200 F, AND 286°F *RECESSED PENDENT STYLE - FM APPROVED 155°F AND 200°F CROSS SECTIONS EXTENDED PENDENT PENDENT 1 I j l I Ii" i 1 -1111 7i t - I 1 RECESSED PENDENT SLEEVE & SKIRT PENDENT GL BE FIRE SPRINKLER CORPORATION JUNE 2009 IMPORTANT INSTALLATION DATA Globe GL Series Dry Pendent sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit. For further important installation data, please refer to our Dry Sprinkler Caution Sheet. ORDERING INFORMATION SPECIFY • Quantity. Model Number • Style • Orifice • Temperature • Finishes desired • Quantity - Wrenches - P/N 333010 • Quantity - Recessed Wrenches - P/N 337014 • Quantity - Protective Caps - P/N 327109 -cap (Friction Fit Recessed) • Escutcheons desired • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used. GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufac- tured products found to be defective in material or workman- ship for a period of one year from date of shipment. For specific details of our warranty, please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com PRINTED U.S.A. BULLETIN GL5635, REV. #12 GL QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION The Globe Quick Response GL Series Dry Type Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Globe Quick Response GL Series Dry Type Pendent Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation ap- proximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, waterflows through the sprinkler and is distributed by the deflector in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Model GL Series sprinkler proven actu- ating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. SURFACE MOUNT SLEEVE & SKIRT TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze • Deflector - brass • Screw - brass • Bulb EXTENDED seat - brass *Spring - teflon coated nickel alloy • Retainer - brass • Pin - stainless steel •Torsion spring - stainless steel • Bulb - glass with alcohol based solution, 3mm • Orifice insert - brass • 3/4" NPT or 1" NPT • Outer tube - galvanized steel pipe • Inner tube stainless steel • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COL RECESSED CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURE .���",, ORDINARYi, INTERMEDIATE- HIGH _��� '.� g A A'» A I ff-s . A tea .-. rte.. .e- a e >�;�'°`��< 7$° ..a:,��;;;..;,, ORANGE/RED /RED YELLOW/GREEN =I BLUE.. .1. �'�' - '" � - - s . •. 4 STANDISH, MICHIGAN 4865 JUNE 2009 A-55 989-846-4583 • FAX 989-846-9231 BULLETIN GL5635, REV.#12 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE SPECK NOMINAL "IC" FACTOR THREAD SIZE 1 LENGTH KNISHES 5.6 (80 metric) 3/4" or 1" NPT cULus Variable 48" FM Variable to36" Factory Bronzeto Satin Chrome' Bright Chrome White Polyester Black Polyester Lead Coated2 8.1 (116 metric) 1" NPT cULus LISTED CORROSION RESISTANT: POLYESTER MUST BE SPECIFIED ON ORDER. 'FINISHES AVAILABLE ON SPECIAL ORDER. ,LEAD COATED IS UL APPROVED ONLY. STYLE SIN MODE- K FACTOR THREAD SZE 135°F 57°C 155°F 68°C 175°F 79•C 200°F 93°C 288°F 141°C " RIA ctLus NYD-DOB MEA 181.92-E PBEIENT GL5635 GL5636 GL8135 5.6 5.6 8.1 1"NPT 3/4" NPT 1"NPT X X X X r X X X X X X X X X - X X X X X X X - X X RECESSEDGL5635 PBVENT N/1TC• 1 ICTGn Ql1D GL5636 GL8135 Al 1 I.IA7A01.10 5.6 5.6 8.1 1"NPT 3/4" NPT 1"NPT X X X X X X X X X X X X X - X X X X X X X - X X "PENDENT STYLE - FM APPROVED 155°F, 200 F, AND 286°F 'RECESSED PENDENT STYLE - FM APPROVED 155°F AND 200°F CROSS SECTIONS L 1 � I EXTENDED PENDENT PENDENT RECESSED PENDENT GL BE FIRE SPRINKLER CORPORATION JUNE2009 L SLEEVE & SKIRT PENDENT IMPORTANT INSTALLATION DATA Giobe GL Series Dry Pendent sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit. For further important installation data, please refer to our Dry Sprinkler Caution Sheet. ORDERING INFORMATION SPECIFY • Quantity. Model Number • Style • Orifice • Temperature • Finishes desired • Quantity - Wrenches - P/N 333010 • Quantity - Recessed Wrenches - P/N 337014 • Quantity - Protective Caps - P/N 327109 -cap (Friction Fit Recessed) • Escutcheons desired • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used. GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufac- tured products found to be defective in material or workman- ship for a period of one year from date of shipment. For specific details of our warranty, please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AI RPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com PRINTEDU.SA. BULLETIN GL5635, REV. #12 FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule ex- ceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depend- ing upon the deflector style used. QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT d PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) TECHNICAL DATA *See reverse side for Approvals and Specifications. *Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) °Water Working Pressure Rating - 175 psi (12 Bars) *Factory tested hydrostatically to 500 psi (34 Bars) •Maximum low temperature glass bulb rating is -67°F (-55°C) 'Frame - bronze • Deflector - brass • Screw - brass °Bulb seat - copper • Spring - nickel alloy ° Seal - teflon °Bulb - glass with alcohol based solution, 3mm size QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL SIDEWALL ° SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURE ORDINARY INTERMEDIATE HIGH 135` /15 °I": °C/-68 C 17a°F120•3"F ;; 93°C 2 1=;._....... 11 °C. : ORANGE/RED YELLOW/GREEN BLUE .i ' _ 38°C "fes°Iw, 66"C 225°- : 07°C 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 MAY 2011 A-20 989-846-4583 • FAX 989-846-9231 BULLETIN GL5615, REV. #7 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT. PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL . CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Bright Chrome GL2815 2.8 X X Satin Chrome 2 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) White Polyester 3 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 2,3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 23 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. APPROVALS ' HORIZONTAL SIDEWALL IS 2 9/16". 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. STYLEF.M.N MODEL FACTOR 135°F 57°C 155°F 68°C 175°F 79°C 200°F 93°C 286°F 141°C cULus F LPC CE NYC DOB MEA 101-92-E GL2815 2.8 X X X X X X XX X — — — X GL4215 4.2 X X X X X — — — X UPRIGHT GL5615 5.6 X X X X X X X X X GL8115 7.8* X X X X X — — — X GL8118 8.1 X X X X X X X X X GL2801 2.8 X X X X X X — — — X GL4201 4.2 X X X X X X — — — X PENDENT GL5601 5.6 X X X X X X X X X X GL8101 7.8° X X X X X X X — — X GL8106 8.1 X X X X X X X X X X VERTICAL GL5632 5.6 X X X X X X X — — — SIDEWALLt GL8133 8.1 X X X X X X — — — — GL2826 2.8 X X X X X X — — — X HORIZONTAL GL4226 4.2 X X X X X X — — — X SIDEWALL § GL5626 5.6 X X X X X X X — — X GL8127 8.1 X X X X X X — — — — CONVENTIONAL GL5624 5.6 X X X X X — — X X — (OLD STYLE) GL8125 8.1 X X X X X — — X X — ORDERING INFORMATION SPECIFY • Quantity • Model Number • Style • Orifice • Thread Sizes • Temperature • Finishes desired • Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.O.) GLBE FIRE SPRINKLER CORPORATION '1/2" NPT t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR L GHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. s HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6". GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufac- tured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com MAY 2011 PRINTED U.S.A. BULLETIN GL5615, REV. #7 HYDRAULIC CALCULATIONS FOR TACO TIME TUKWILLA TUKWILLA, WASHINGTON FILE NUMBER: C1129 DATE: 10/03/11 -DESIGN DATA - OCCUPANCY CLASSIFICATION: Oror,44v j "r - DENSITY: DENSITY: RESIDENTIAL .15 gpm/sq. ft. AREA OF APPLICATION: 945 sq. ft. COVERAGE PER SPRINKLER: 128 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 10 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 241.0 gpm TOTAL WATER REQUIRED (including hose): 491.0 gpm FLOW AND PRESSURE (@ BOR): 241.0 gpm @ 54.4 psi SPRINKLER ORIFICE SIZE: 12 inch NAME OF CONTRACTOR: COLUMBIA FIRE, INC. DESIGN/LAYOUT BY: STEVE ADAMSON AUTHORITY HAVING JURISDICTION:-RCDMOND FIRE DEPARTMENT fives 1 q CONTRACTOR CERTIFICATION NUMBER: COLUMF1952MG CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 50110271) HRS SYSTEMS, INC. TUCKER, GA 30084 TUCKER, GA 30084 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/5/2011 C:\HASS\DATA\STEVE ADAMSONS CALCS\C1129.SDF JOB TITLE: TACO TIME TUKWILLA Av99.2LRe56A.B. System Demand Curve LGVGIVL 2 Static: 101.00 psi Resid:/57.00 psi Flow: 2800.0 gpm 120.0 / 100.0 80.0 60.0 40.0 20.0 GAUGE PRESSURE ( p s i) 3000 2700 - 2400 2100 FLOW - 1800 1500 1200 900 600 0.0 -14.7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 10/5/2011 C:\HASS\DATA\STEVE ADAMSONS CALCS\C1129.SDF JOB TITLE: TACO TIME TUKWILLA NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 30 101.0 57.0 2800.0 99.2 491.0 56.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 491.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 241.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 11.3 K= 5.60 11.8 19.2 2 11.3 K= 5.60 12.7 20.0 3 11.3 K= 5.60 19.5 24.7 4 11.3 K= 5.60 22.5 26.5 5 10.9 K= 5.60 11.9 19.4 6 10.9 K= 5.60 13.2 20.4 7 10.9 K= 5.60 20.0 25.1 8 10.9 K= 5.60 23.1 26.9 9 10.9 K= 5.60 26.1 28.6 10 10.9 K= 5.60 29.1 30.2 11 11.3 28.2 12 10.9 14.0 13 10.9 29.0 14 10.8 32.4 15 10.8 35.0 16 10.8 35.5 17 10.8 36.1 18 10.5 36.6 19 10.5 37.0 20 10.5 37.7 21 10.5 38.7 22 11.3 33.7 23 10.9 34.7 24 10.8 36.6 25 10.5 39.2 26 10.5 46.0 27 4.0 51.4 28 4.0 54.4 29 0.5 - - - - 55.9 - - - 30 0.0 SOURCE 56.5 241.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/5/2011 C:\HASS\DATA\STEVE ADAMSONS CALCS\C1129.SDF JOB TITLE: TACO TIME TUKWILLA NFPA PIPE DATA Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) I\ To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 5.60 19.2 Disch 2 11.3 12.7 0.0 1 11.3 11.8 19.2 Pipe: 2 5.60 20.0 Disch 3 11.3 19.5 19.2 1 2 11.3 12.7 39.2 Pipe: 3 5.60 24.7 Disch 4 11.3 22.5 39.2 2 3 11.3 19.5 63.9 Pipe: 4 5.60 26.5 Disch 11 11.3 28.2 63.9 3 4 11.3 22.5 90.4 Pipe: 5 5.60 19.4 Disch 12 10.9 14.0 0.0 5 10.9 11.9 19.4 Pipe: 6 5.60 20.4 Disch 12 _0.9 14.0 0.0 6 10.9 13.2 20.4 Pipe: 7 5.60 25.1 Disch 8 10.9 23.1 39.7 12 7 10.9 20.0 64.8 Pipe: 8 5.60 26.9 Disch 13 10.9 29.0 64.8 7 8 10.9 23.1 91.7 1.000 1.049 1.000 2E: 4.0 1.049 1.250 1.380 1.250 1.380 1.000 E: 2.0 1.049 1.000 T: 5.0 1.049 1.250 1.380 1.250 1.380 8.00 120 0.00 8.00 0.121 10.92 120 4.00 14.92 0.451 10.25 120 0.00 10.25 0.293 10.25 120 0.00 10.25 0.558 14.50 120 2.00 16.50 0.122 0.50 120 5.00 5.50 0.135 10.33 120 0.00 10.33 0.301 10.25 120 0.00 10.25 0.573 1.0 0.0 1.0 6.7 0.0 6.7 3.0 0.0 3.0 5.7 0.0 5.7 2.0 0.0 2.0 0.7 0.0 0.7 3.1 0.0 3.1 5.9 0.0 5.9 Pipe: 9 5.60 28.6 Disch 15.75 120 6.3 14 10.8 32.4 0.0 1.000 2E: 4.0 9.00 0.0 9 10.9 26.1 28.6 1.049 T: 5.0 24.75 0.252 6.2 Pipe: 10 5.60 30.2 Disch 18 10.5 36.6 0.0 10 10.9 29.1 30.2 Pipe: 11 0.0 0.0 22 11.3 33.7 90.4 4 11 11.3 28.2 90.4 Pipe: 12 0.0 0.0 7 10.9 20.0 39.7 12 10.9 14.0 39.7 14.33 120 1.000 E: 2.0 12.00 1.049 2T:10.0 26.33 0.279 1.500 T: 8.0 1.610 1.000 2E: 4.0 1.049 13.08 120 8.00 21.08 0.263 9.08 120 4.00 13.08 0.463 7.5 -0.2 7.3 5.5 0.0 5.5 6.1 0.0 6.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 10/5/2011 C:\HASS\DATA\STEVE ADAMSONS CALCS\C1129.SDF JOB TITLE: TACO TIME TUKWILLA Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) n To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 13 23 13 Pipe: 14 15 14 Pipe: 15 16 15 Pipe: 16 17 16 Pipe: 17 24 17 Pipe: 18 19 18 Pipe: 19 20 19 Pipe: 20 21 20 Pipe: 21 25 21 Pipe: 22 23 22 Pipe: 23 24 23 Pipe: 24 25 24 Pipe: 25 26 25 10.9 10.9 10.8 10.8 10.8 10.8 10.8 10.8 10.8 10.8 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.9 11.3 10.8 10.9 10.5 10.8 10.5 10.5 0.0 34.7 29.0 0.0 35.0 32.4 0.0 35.5 35.0 0.0 36.1 35.5 0.0 36.6 36.1 0.0 37.0 36.6 0.0 37.7 37.0 0.0 38.7 37.7 0.0 39.2 38.7 0.0 34.7 33.7 0.0 36.6 34.7 0.0 91.7 8 91.7 0.0 28.6 28.6 0.0 28.6 14 28.6 0.0 28.6 15 28.6 0.0 28.6 16 28.6 0.0 30.2 30.2 0.0 30.2 18 30.2 0.0 30.2 19 30.2 0.0 30.2 20 30.2 0.0 90.4 11 90.4 90.4 22 91.7 13 182.1 0.0 182.1 23 39.2 28.6 17 36.6 210.7 0.0 210.7 24 46.0 30.2 21 39.2 240.9 1.500 T: 8.0 1.610 1.000 1.049 1.250 1.380 1.250 1.380 1.500 T: 8.0 1.610 1.250 1.380 1.250 1.380 1.500 2E: 8.0 1.610 13.08 120 8.00 21.08 0.270 10.17 120 0.00 10.17 0.252 7.50 120 0.00 7.50 0.066 10.00 120 0.00 10.00 0.066 6.67 120 8.00 14.67 0.031 4.67 120 0.00 4.67 0.073 9.83 120 0.00 9.83 0.073 22.00 120 8.00 30.00 0.035 18.83 120 2.000 E: 5.0 25.00 2.067 2T:20.0 43.83 0.010 2.000 2.157 2.000 2.157 2.000 2.157 2.000 2E:12.3 2.157 12.50 120 0.00 12.50 0.063 8.00 120 0.00 8.00 0.231 8.17 120 0.00 8.17 0.303 5.25 120 12.31 17.56 0.388 5.7 0.0 5.7 2.6 0.0 2.6 0.5 0.0 0.5 0.7 0.0 0.7 0.5 0.0 0.5 0.3 0.0 0.3 0.7 0.0 0.7 1.0 0.0 1.0 0.4 0.0 0.4 1.0 - 0.2 0.8 1.9 0.0 1.9 2.6 - 0.1 2.5 6.8 0.0 6.8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 10/5/2011 C:\HASS\DATA\STEVE ADAMSONS CALCS\C1129.SDF JOB TITLE: TACO TIME TUKWILLA Pipe Tag K-fac Add F1 Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) I\ To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 26 0.0 0.0 27 4.0 51.4 240.9 25 26 10.5 46.0 240.9 2.000 2.157 6.50 120 5.3 0.00 -2.8 6.50 0.388 2.5 Pipe: 27 0.0 Fixed Pressure Loss Device 28 4.0 54.4 240.9 26 3.0 psi, 240.9 gpm 27 4.0 51.4 240.9 Pipe: 28 0.0 0.0 29 0.5 55.9 240.9 27 28 4.0 54.4 240.9 4.000 4.260 1.00 120 0.00 1.00 0.014 1.5 -1.5 0.0 Pipe: 29 Source 0.0 2E:44.0 122.00 140 0.6 30 0.0 56.5 240.9 28 D6.000 2T:94.0 143.00 -0.2 29 0.5 55.9 241.0 6.280 G: 5.0 265.00 0.002 0.4 NOTES (HASS): (1) Calculations were performed by the HASS 8.2 computer program under license no. 50110271 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.127 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 21..2 ft/sec at pipe 25. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP 134 INCORPORATED CORONA, CA • (909)737-5599 FIG.1000 "FAST CLAMP" SWAY BRACE ATTACHMENT Size Range - Pipe size to be braced: 1 thru 8 inch Schedule 10 thru 40. Pipe size used for bracing: 1 and 1-1/4 inch Schedule 40 IPS. Material - Carbon Steel. Function - For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1000 is used in conjunction with a Tolco 900 Series Fitting and joined together with bracing pipe per NFPA #13*, forming a complete sway brace assembly. Features - Can be used to brace Schedules 10 thru 40 IPS. Field adjustable, making critical pre -engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as 4 -way riser brace. Can be used as longitudinal brace. All steel construction eliminates structural deficiencies associated with casting type sway brace fittings. Comes individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Application Note - Fast Clamp need not be field assembled. Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1 inch pipe extension beyond the Fig. 1000 is recommended. * Length of bracing pipe per National Fire Protection Association, Pamphlet #13, paragraph A-3-10.3.5: 1 inch Schedule 40 bracing pipe maximum 7'4", 1-1/4 inch Schedule 40 bracing pipe maximum 9'-0". Approvals - Underwriters' Laboratories Listed. Approved by State of California Office of Statewide Health, Planning and Development (OSHPD). Finish - Plain, Electro -Galvanized, HDG, and Stainless Steel. Order By - Order first by pipe size to be braced followed by pipe size used for bracing, figure number, and finish. Important Note - The Fig. 1000 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance. the U.L. Listing¢ requires that the Fir. 1000 must be used only with other Tolco bracini products 0 State of California OSHPD APPROVED Horizontal Design Load 2015 lbs. Fig. 980 f TO INCORPORATED CORONA. CA • (909)737-5599 FIG.909 NO -THREAD SWIVEL SWAY BRACEATTACHMENT Size Range - 1 and 1-1/4 inch bracing pipe. For brace pipe sizes larger than 1-1/4 inch use Tolco Fig. 980. Material - Carbon Steel, hardened cone point engaging screw. Function - The structural component of a sway and seismic bracing system. Features - • No threading of the bracing pipe is required. • Open design allows for easy inspection of pipe engagement. • All steel construction eliminates deficiencies associated with malleable type attachments. • Fastener can be mounted to all surface angles. Application Note -The Fig. 909 is used in conjunction with the Tolco Fig. 1000 "Fast Clamp ", Fig. 2001, or Fig. 4(A) pipe clamp, and joined together with bracing pipe. Install per NFPA #13 and/or Tolco's State of Califomia OSHPD Approved Seismic Restraint Manual. Installation - Extend bracing pipe through part until it contacts swivel piece or pivot bolt. Tighten cone point engaging screw until head bottoms out. Approvals - Underwriters Laboratories Listed. Approved by State of California Office of Statewide Health, Planning and Development (OSHPD). Finish - Plain, Electro Galvanized and HDG. Order By - Figure number, pipe size and finish. Important Note - The Fig. 909 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the U.L. Listinn reunites that the Fie. 909 must be used only with other Tolco bracine products. NATIONAL AND INTERNATIONAL PATENT APPLICATIONS IN PROCESS. PIPE SIZE A B W 1 6 1-5/8 17/32 1-1/4 6 1-5/8 17/32 * Available with hole sizes to Consult Factory MAX. MAX. DESIGN DESIGN LOAD LBS. LOAD W/WASHER LBS. 2015 2765 2015 2765 accommodate up to 3/4" fastener. APPROX. WT./100 91 97 131 State of California OSHPD APPROVED SILENT KNIGHT by Honeywell INTELLIKNIGHT MODEL 5700 Addressable Fire Control Panel Installation and Operations Manual Part Number 151295 Rev F INTELLIKNIIGHT FIRE ALARM CONTROL PANEL IntelliKntght® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control panel solution. IntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description 5700 performs drift compensation and calibration checks on each of the sensors in the system The basic IntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Up to 50 addressable points • Up to 125 zones and 125 output groups • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator. • Central station reporting by point or by zone - • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC • Distributed, intelligent power • Drift compensation • 13 pre-programmed output cadences (including ANSI -3.41) and 4 programmable outputs • Notification circuits configurable as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power • Built-in synchronization for AMSECO, Gentex®, Faraday, System Sensor® and Wheelock® appliances • Built-in annunciator with 80 -character LCD display • RS -485 bus provides communication to system accessories • Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) • Improvements in SKSS deliver five times faster upload/downloads • Built-in RS -232 interface for programming via PC • Built-in Form C trouble relay rated at 2.5A at 27.4 VDC • Two built-in Form C programmable relays rated at 2.5A at 27.4 VDC • Programmable date setting for Daylight Saving Time Electrical Specifications Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC Notification Power: 2.5A @ 27.4 VDC, power -limited Standby Current: 200 mA Alarm Current: 325 mA Notification/Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power -limited Battery Charging Capacity: 7.0-35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet. Mechanical Specifications Dimensions: 12.75" W x 15.2" H x 3.4" D (32.39 W x 38.42 H x 8.57 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Model 5700 Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 144; MEA 429-92-E Vol. XVI. SILENT KNIGHT A by Honeywell INTELLIKNIGHT FIRE ALARM CONTROL PANEL SLC Detectors SD505-APS Addressable photoelectric smoke detector. SD505-AIS Addressable ionization smoke detector. SD505-AHS Absolute temperature heat detector that goes into alarm immediately if the temperature exceeds the programmable trip point. Trip point range from 135°F -150°F (0°C -37°C). SD505-6AB Six inch base for use with detector heads SD505-APS, SD505-AIS and SD505-AHS. SD505-4AB Four inch base for use with detector heads SD505-APS, SD505-AIS, and SD505-AHS. SD505-6SB Six-inch sounder base for use with existing sensor and base. Operates in single and multi -station modes and/or as a system sounder. Requires 2 additional wires for power. SD505-61B Short circuit isolator base for SD505-AHS, SD505-APS, and SD505-AIS detectors. SD505-6RB Six-inch relay base for use with existing sensor and base. Provides one Form C contact. SD505-ADH Duct housing that detects smoke in HVAC ducts. SD505-ADHR Duct detector base with relay. Provides Form C alarm contact. For use with SD505-APS and SD505-AIS sensors. Compatible with SD505-DTS remote test switch. SD500-PS/SD500-PSDA SD500-PS is a single action pull station and SD500-PSDA is a dual action pull station. SLC Modules Model SD500-AIM Dry contact input module for use with normally open dry contacts. It features an indicator LED to show alarm status. SD500-MIM Mini dry contact input module is a small version of the SD500-AIM. For use with pull stations and other normally open dry contact inputs. SD500-ANM Addressable notification module providing a single Class A or Class B notification circuit on the SLC. SD500-ARM Addressable relay module that features two Form C output relays. Provides indicator LED to show output status. SD500-SDM Two -wire detector input module. Allows for the connection of conventional 2 -wire detectors on the SLC loop. Requires two additional wires for power. SD500-LIM A short circuit isolator module for SLC devices. When a short occurs on the SLC loop, it is detected as a trouble, but all SLC devices protected by the isolator module continue to operate. SD500-LED An LED driver capable of driving 80 LEDs through the SLC loop. Up to 40 SD500-LEDs can be used per system. S -BUS Accessories 5860/R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power -limited notification appliance circuit outputs. 5880 LED/IO Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS -232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite User-friendly Windows software for remote programming of 5700s using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End-user facility management software allows viewing of detector status and event history via modem or direct connection. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SD505-DTS Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505-ADHR. 50505410101 50506F5 SD%S*+ N 5700 5496 SILENT KNIGHT Mir by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. IntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight MADE IN AMERICA FORM# 350392 Rev. D, 04/06 Copyright © 2006 Silent Knight INTELLIKNIGHT ACCESSORY Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal -resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS Analog / Addressable Photoelectric Type Smoke Detector The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contarnination and a simple detector calibration test procedure that can be run from the panel or remotely (using the Windows based downloading software). Operation The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features • Low profile, 2 inches, including base • Simple and reliable addressing without mechanical switches • Automatic compensation for sensor contamination • Built-in fire test feature • Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. • Vandal -resistance locking features • Field cleanable • UL listed, meets NFPA 72 Ch 7 requirements • CSFM approved • MEA approved • FM Approved SD505-APS Smoke Detector Specifications Operating Voltage: 17-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Ambient Temperature:32°F to 120°F (0°C to 49°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: 0 - 300 FPM Compatible Bases: SD505-6AB (Sold Separately) (6" Base) SD505-4AB (4" Base) SILENT KNIGHT by Honeywell INTELLIKNIGHT ACCESSORY Model SD505-APS Addressable Photoelectric Type Smoke Detector Engineering Specifications The contractor shall fumish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist -lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for extemal test apparatus. The vandal -resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter = 3-15116" Height = 2 inches, including base Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) ft SILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more Information, contact Silent Knight 7550 Meridian Cirde Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350225 Rev C,. 05/05 Copyright © 2005 Silent Knight INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA Addressable Pull -Station IntelliKnight's addressable pull stations combine fast response with pin -point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knights IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practicalmeans of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & SD500-PSDA Addressable Pull Station The SD500-PS is a single action addressable fire pull station, and the SD500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an IntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features • UL Listed • CSFM listed • ADA compliant • Key reset (Same key as Silent Knight enclosures) • Surface mount back box available • Terminals - accept up to 14 gauge wire • Extremely easy to operate • Corrosion -resistant gold-plated contacts. • Reflective label makes it easier to locate in low light Operation The SD500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by retuming the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500-PS/PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDC Standby Current: Alarm Current: .55mA .55mA SD500-PS Ambient Temperature: Mounting: 32°F to 120°F (0°C to 49°C) Single gang box - Optional Red Surface Mount Box PS-SMBB SILENT .23 KNIGHT I.1 Ar,rt.F # :::r.p ny INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA Addressable Pull -Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. • - - i3 .• ; �s 3 • - • i *a I Mounting to Single Gang Electrical Box Mounting to Optional Surface Mount Box SD500-PSDA Installing SD500-LK Sd I - Wiring 3.12" Dimensions Electrical ©i must be at bast Oen SILENT KNIGHT til. ory-wii Ciro F+rlt 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350342, Rev. 09/03 Copyright © 2003 Silent Knight INTELLIKNIGHT ACCESSORY water flow switches, SD500-AIM & SD -500 -MIM Addressable Input Modules IntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4" -square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description The SD500-AIM and SD500-MIM are addressable input modules for use with the Intelliknight fire alarm control panels (FACPs). The SD500-AIM addressable input module mounts to a 4" -square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features • Single contact monitor • Support for Class A (Style 6 & Style 7) or Class B (Style 4) wiring • Attractive ivory cover plate with the SD500-AIM • Small and lightweight size allows for flexible mounting options with the S D500 -M I M • DIP switch programmable for Fast installation • Up to 2500 ft wiring distance from either input module to contact • Use up to 14 gauge wire • UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device Line Resistance: 500 max Mechanical Specifications SD500-AIM Physical Description Dimensions: 4.9" W x 4.9" H x 1" D (12.4Wx 12.4Hx2.5Dcm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5" W x 2.5" H x 0.7" D (3.8 W x 6.4 H x 1.8 D cm) Weight: 1.6 oz (45.4 g) Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing SD500-AIM SD500-MIM Approvals NFPA 71 & NFPA 72 UL 864 CSFM 7300-0559: 132 MEA 429-92-E Vol. IX FM Approved for use with the 5820XL SILENT KNIGHT by Honeywell INTELLIKNIGHT ACCESSORY t SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4" -square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate To contact being monitored • 1 71 EOL All Wiring is Supervised Power Limited To contact being monitored •, 1.7k EOL Compatibility IntelliKnight 5820 FACP IntelliKnight 5808 FACP IntelliKnight 5700 FACP Ordering Information SD500-AIM Input Module Addressable input module with ivory cover plate. SD500-MIM Mini Input Module Addressable mini input module. SILENT KNIGHT by Honeywell This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350231 Rev.C, 05/06 Copyright © 2006 Silent Knight SYSTEM SENSOR® Outdoor Selectable - Output Horns, Strobes, and Horn Strobes SpectrAlert' Advance outdoor selectable -output horns, strobes, and horn strobes are rich with features that cut installation times and maximize profits. Features • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela • Field -selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Universal mounting plate for wall- and ceiling -mount units • Mounting plate shorting spring tests wiring continuity before devices are installed • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Rated from —40°F to 151°F • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Agency Listings SIGNAUNG 0 LISTED S4011 (dames, horn strobes, horns) 53593 (outdoor and alert strobes) APPROVED 3023572 MEA approved MEAd52-054 7300-1653.187 (outdoor strobes) 7125-1653:188 thorn strobes. clime strobes) 7135-1653:189 (hams, climes) SPECTRAlert The SpectrAlert Advance series offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement. SpectrAlert Advance outdoor horns, strobes, and horn strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from —40°F to 151 °F. Like the entire SpectrAlert Advance product line, these devices include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. All horns, strobes, and horn strobes use a universal mounting plate with an onboard shorting spring that tests wiring continuity before the device is installed, protecting devices from damage. In addition, field -selectable candela settings, automatic selection of 12- or 24 - volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns, strobes and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12 -volt -rated notification appliance circuit outputs shall operate between 9 and 175 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115,135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three -pattern and a non -temporal (continuous) pattern.These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non -coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 1517 (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangel 8 to 175 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 25" high (173 mm diameter x 64 mm high) Wall -Mount Dimensions (including Tens) 5.6'Lx4.7'Wx25-D(142mmLx119mmWx64mm D) Horn Dimensions 5.6'Lx4.7"Wx1.3-D(142mmLxll9mmWx33mmD) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"L x 5.1"W x 2.0"D (145 mm L x 130 mm W x 51 mm D) Ceiling -Mount Weatherproof Back Box Dimensions (SA-WBBC) 7.1' diameter x 2.0' high (180 mm diameter x 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard Candela Range 15 123 128 66 71 Temporal High 57 55 69 75 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 176 Non Temporal Medium 42 50 60 69 195 Non Temporal Low 41 44 50 50 High Candela Range 95 110 115 135 150 177 185 NA NA NA NA NA NA NA NA NA NA NA NA NA NA 181 202 210 228 246 281 286 205 Coded High 57 55 69 75 207 Coded Medium 44 51 56 69 220 Coded 251 258 Low 40 46 52 50 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, Standard Candela Range (15-115 cd) DC Input 8-17.5 Volts 16-33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, High Candela Range (135-185 cd) DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High Temporal Medium 245 259 290 297 Temporal High 215 231 258 265 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Candela rating at -40°F Listed Candela 15 15/75 Do not use below 32°F 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Horn Tones and Sound Output Data Horn and Hom Strobe Output (dBA) Switch Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non -Temporal Medium 78 78 85 85 90 90 98 98 6 Non Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 Settings 7, 8, and 9 are not available on 2 -wire horn strobe. 8-175 16-33 24 -Volt Nominal Volts Volts Reverberant Anechoic A05-0456001 SpectrAlert Advance Dimensions Wall -mount hom strobes Ceiling -mount horn strobes Wall weatherproof back box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK0 2 -Wire Horn Strobe, Standard cd, Red, Outdoor P2RHK"t 2 -Wire Horn Strobe, High cd, Red, Outdoor P2WK"t 2 -Wire Horn Strobe, Standard cd, White, Outdoor P2WHK"1 2 -Wire Horn Strobe, High cd, White, Outdoor P4RKt 4 -Wire Horn Strobe, Standard cd, Red, Outdoor P4WK 4 -Wire Horn Strobe, Standard cd, White, Outdoor P2RHK-120 2 -Wire Horn Strobe, High cd, Red, Outdoor, 120V Wall Strobes SRK"t Strobe, Standard cd, Red, Outdoor SRHK"t Strobe, High cd, Red, Outdoor SWK"t Strobe, Standard cd, White, Outdoor SWHK"t Strobe, High cd, White, Outdoor Notes: Ceiling weatherproof back box Model Description Ceiling Hom Strobes PC2RK 2 -Wire Horn Strobe, Standard cd, Red, Outdoor PC2RHK 2 -Wire Horn Strobe, High cd, Red, Outdoor PC2WK 2 -Wire, Horn Strobe, Standard cd, White, Outdoor PC2WHK 2 -Wire, Horn Strobe High cd, White, Outdoor PC4WK 4 -Wire, Horn Strobe, Standard cd, White, Outdoor PC4WHK 4 -Wire, Horn Strobe, High cd, White, Outdoor Ceiling Strobes SCRK Strobe, Standard cd, Red, Outdoor SCRHK Strobe, High cd, Red, Outdoor SCWK Strobe, Standard cd, White, Outdoor SCWHK Strobe, High cd, White, Outdoor Horns HRK Horn, Red, Outdoor " Add '-P'to model number for plain housing (no'FIRE'marking on cover), e.g, P2RK-P. t Add '-R'to model number for weatherproof replacement device (no back box included), especially for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd'refers to strobes that include 15,15/75, 30, 75, 95,110, and 115 candela settings.'High cd'refers to strobes that indude 135, 150, 177, and 185 candela settings. SYSTEM SENSOR`' 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 02009 System Sensor Product specifications sublsttochange vnthout noticel6sn systemsensorcarn for current product udorm.mon,mdudmg the latesteason of the data sheet ACS -0456-00l. 06/09.12190 SYSTEM SENSOR° Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlerrAdvance selectable -output horns, strobes, and horn/strobes are rich with,features guaranteed to cut installation times and maximize profits. Features • Electrically compatible with existing SpectrAlert products `\ • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela • Plug-in design • Field selectable candela settings on wall and ceiling units: 15, 15/75, 30,75,95,110,115,135,150,177,185 • Same mounting plate for wall- and ceiling -mount units • Shorting spring on mounting plate for continuity check before installation •Tamper resistant construction • Outdoor wall and ceiling products rated from —40°F to 151°F • Design allows minimal intrusion into the back box • Horn rated at 88+ dbA at 16 volts • Rotary switch for horn tone and three volume selections • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements • Outdoor products NEMA 4X rated • Compatible with MDL sync module Agency Listings SIGIIAUNG 0 LISTED 54011 55512 33593 APPROVED 3023572 MEA approved MEA452-05{ 7125-1653186 indoor strobes) 7300-1653:187 (outdoor strobes) 71251653188 O,,Nstrobes. dddmdsbobesl 7135.1653:189 thorns, domes) SPECTFlert A V O N C E The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field -selectable candela settings for wall and ceiling strobes and hom/strobes. When installing Advance products, first attach a universal mounting plate to a four -inch square, four -inch octagon or double -gang junction box.The two -wire mounting plate attaches to a single -gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position, locking the product's pins into the mounting plate's terminals.The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance homs, strobes and hom/strobes shall mount to a standard 4 x 4 x 11/2 -inch back box, 4 -inch octagon back box or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 11/s -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 175 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field -selectable candela settings including 15,15/75, 30, 75, 95,110,115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn%Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe 5ght shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three -pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on hom/strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and hom/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync{ircuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the homs on horn/strobe models over a single pair ofwires.The module shall mount to a 4J1/16 x 41/4 x 2'/e -inch back box. The module shall also control two Style Y (dass B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0"C to 49°C) K Series Operating Temperature —40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non -condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR1 Operating Voltage Rangel 8 to 175 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to18AWG Ceiling mount dimensions (including lens) 6.8" diameter x 25"high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61 x 4.7"W x 25D (142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61x4.7Wx13'D(142mmLx119mmWx33mmD) Wall -mount back box skirt dimensions (BBS -2, BBSW-2) 5.91 x 5.0W x 221D (151 mm L x 128 mm W x 56 mm D) Ceiling -mount back box skirt dimensions (BBSC-2, BBSCW-2) 7.1" diameter x 2.25" high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA-WBB) 5.71. x 5.1 W x 2.0"D (145 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA-WBBC) 7.1" diameter x 2.0" high (180 mm diameter x 51 mm high) Wall -mount trim ring dimensions (TR -HS, TRW -HS) 5.71 x 4.812W x 0351)(146 mm L x 122 W mm x 9 D mm) Ceiling -mount trim ring dimensions (TRC-HS,TRCW-HS) 6.9" diameter x 035 high (176 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12V nominal only for 15 and 15/75 cd. UL Current Draw Data UL Max.Strobe Current Draw (mA RMS) 8-175 Volts 16-33 Volts UL Max. Horn Current Draw (mA RMS) Candela DC FWR DC FWR Sound Pattern Standard Candela Range 15* 123 128 66 71 Temporal 15/75* 142 148 30* NA NA 75* NA NA 95• NA NA 110 NA NA 115 NA NA NA NA NA NA NA NA NA High Candela Range 135 150 177 185 NA 77 81 Temporal 94 96 158 181 202 210 228 246 281 286 153 176 195 205 207 220 251 258 Temporal Non -temporal Non -temporal Non -temporal Coded Coded Coded 8-17.5 Volts 16-33 Volts dB DC FWR DC FWR High 57 55 69 75 Medium 44 49 58 69 Low 38 44 44 48 High 57 56 69 75 Medium 42 50 60 69 Low 41 44 50 50 High 57 55 69 75 Medium 44 51 56 69 Low 40 46 52 50 UL Max. Current Draw (mA RMS), 2 -wire Horn/Strobe, Standard Candela Range (15-115 cd) DC Input 8-17.5 Volts 16-33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Nontemporal High 141 152 91 100 116 176 201 221 229 Nontemporal Medium 133 145 75 85 102 163 187 207 216 Nontemporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High Temporal Medium Temporal Low Non -temporal High Non -temporal Medium Non -temporal Low 136 129 129 142 134 132 155 152 151 161 155 154 88 78 76 103 85 80 97 88 86 112 95 90 112 103 101 126 110 105 168 160 160 181 166 161 190 184 184 203 189 184 210 202 194 221 208 202 218 206 201 229 216 211 UL Max. Current Draw (mA RMS), 2 -wire Horn/Strobe, High Candela Range (135-185 cd) DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 " 292 Temporal Low 207 221 248 256 Non -temporal High 255 270 303 309 Non -temporal High 233 248 275 281 Non -temporal Medium 242 259 293 299 Non -temporal Medium 219 232 262 267 Non -temporal Low 238 254 291 295 Nontemporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at -40°F 15 Do not use below 32*F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Horn Tones and Sound Output Data Horn and Horn/Strobe Output (dBA) Switch 8-17.5 16-33 24 Volt Nominal Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non -temporal High 82 82 88 88 93 92 100 100 5 Non -temporal Medium 78 78 85 85 90 90 98 98 6 Non -temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8+ Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2 -wire horn/strobe. AO5-0395-005 SpectrAlert Advance Dimensions 5.98' Wall -mount horn/strobes 5.05"--1x2.23+1 O 2.251 Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Wall Hom/Strobes P2R*t 2 -wire Horn/Strobe, Standard cd*, Red P2RH* 2 -wire Horn/Strobe, High cd, Red P2RK*° 2 -wire Horn/Strobe, Standard cd, Red, Outdoor P2RHK° 2 -wire Horn/Strobe, High cd, Red, Outdoor P2W* 2 -wire Horn/Strobe, Standard cd, White P2WH* 2 -wire Horn/Strobe, High cd, White P4R* 4 -wire Horn/Strobe, Standard cd, Red P4RH* 4 -wire Horn/Strobe, High cd, Red P4R10 4 -wire Horn/Strobe, Standard cd, Red, Outdoor P4RHK° 4 -wire Hom/Strobe, High cd, Red, Outdoor P4W* 4 -wire Hom/Strobe, Standard cd, White P4WH* 4 -wire Horn/Strobe, High cd, White Wall Strobes SR*t Strobe, Standard cd, Red SRH** Strobe, High cd, Red SRK° Strobe, Standard cd, Red, Outdoor SRHK Strobe, High cd, Red, Outdoor SW* Strobe, Standard cd, White SWH* Strobe, High cd, White Ceiling Horn/Strobes PC2R* 2 -wire Horn/Strobe, Standard cd, Red PC2RH* 2 -wire Horn/Strobe, High cd, Red PC2RK° 2 -wire Horn/Strobe, Standard cd, Red, Outdoor PC2RHK° 2 -wire Horn/Strobe, High cd, Red, Outdoor PC2W*t 2 -wire Horn/Strobe, Standard cd, White PC21NH*t 2 -wire Horn/Strobe, High cd, White PC4R 4 -wire Horn/Strobe, Standard cd, Red PC4RH 4 -wire Horn/Strobe, High cd, Red PC4RK 4 -wire Horn/Strobe, Standard cd, Red, Outdoor PC4RHK° 4 -wire Horn/Strobe, High cd, Red, Outdoor Ceiling -mount horn/strobes A 2.0' Dia. Wall weatherproof back box Ceiling weatherproof back box Model Description Ceiling Hom/Strobes (contd.) PC4W 4 -wire Hom/Strobe, Standard cd, White PC4WH 4 -wire Horn/Strobe, High cd, White Ceiling Strobes SCR* Strobe, Standard cd, Red SCRH* Strobe, High cd, Red SCRK° Strobe, Standard cd, Red, Outdoor SCRHK° Strobe, High cd, Red, Outdoor SON** Strobe, Standard cd, White SCWH*t Strobe, High cd, White Homs HR Hom, Red HRK° HW Horn, Red, Outdoor Horn, White Accessories BBS -2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR -HS Trim Ring, Wall, Red TRW -HS Trim Ring, Wall White TRC -HS Trim Ring, Ceiling, Red TRCW-HS Trim Ring, Ceiling, White Notes: * Add'-P'to model number for plain housing (no 'FIRE' marking on cover), e.g, P2R-P. t Add -SP'to model number for'FUEGO'marking on cover, e.g., P2R-SP. #'Standard cd; refers to strobes that include 15,15/75, 30, 75, 95,110, and 115 candela settings.'High cd,°refers to strobes that indude 135,150,177, and 185 candela settings. All outdoor units ending in'K•include a weatherproof back box. o Add -R'to model number for weatherproof replacement device (no back box included). � NEM SOR` 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax 630-377-6495 02008Systen Sensor. Productsperthodons010eatochingevAdvutncaceVesasystemursccoomfer ane[ pma¢t H°tmaeorvIndudeg the latestversion dthis data thee. AMS -039S-005. 8/08.12018 W Noe �`�u' Io p$ fv l a 50 �s�. Lfii resr! 4xzk. R,y-- z7 �IKII a gi 1 Z6 14/14k/AJS 4„ 3s-oAA984 Dog Zq T1 a 1'4x// gip, -IRE SPRINKLER 112 © N L'7 aC L If 3-c( �I u 3 Z -d NOM ER° -4 - run NAL GAS ELEC CAB W4 I W2 SLO/ce [/P 8-z- 4/14 5-Z -o o -q , s 1` • 4", EXIT s-/ ' - rJ aiN - - 4o DINING nun R1- / HALL® -0 0-4 1/O DRY >.< EXIT/ STORAGE z- 1, T3 T3 T2 zPLx 9-Ze W2 Bp, T✓/' zZ A,3 j'7 1 �-z GOD \1'�9 R1- -A4.1 - W2 W2 pians on _ • ,v >= --- 'n�+.�, r' rat i = - - - e^'. Tl.4.v a F -'y --_ - =c` a Fire - - _ C°-ty e1 a- 2.;-.3-7-;75-4407 am J!1. i. tin ilL Pc1i9itt c nd exact add --:ss for shLt- - _y4-, i or reStorat on approval. OPEN CEILING TO TRUSSES T4 1) ,k” �� ?1J%-‘54 4,0 31 Siete q` c cv-t`P'74-(re( .t,✓ - low_ CEIUNG HT 8-'0' AFF o ©� I 1 W4 �J t! 0-Z irsor- Cel Z 00 0 - KI HEN 4- 1- \71 F2 OPEN CEILN TO TRUSSES 11'+ AFF O GENERAL NOTES - I. Ail material and equipment to be new and wde,writeru approved - 2 Piping dbmmalav are end to end gr. 0") 3 Earthquake bracing *rail be provided in accordance with NFPA pamphlet number 13 - 4 Pips hatgee and method of hargirg to be in accedence with NFPA pamphlet number 13 - - 1)Piping shall be accordance with pamphlet number 13 - - ii Joiiing of pipe and Jlttirge, threaded and welded shall be in accordance with NFPA pamphlet 13 - 7 Owner to provide adequate heat to prevent water in pipe JFa'freezing to areas protected by a wet pipe 'sprinkler mean. 8 Structural adsquancy myths building to eupport the sprinkler piping 1e the reeponaiblity Lythe owner andlorstructural reanrsenraitvea. - EARTH QUAKE BRACE 9, afpk✓ J V ,fiffz . to 573977C- /0/ PS/ RD'S, - S"7 /Os/ w/ 28x6 c/M • =coot- P�JW //4/z, /9 !/GR. r J Gill/sf► 4- 4f w►ctIti -CO -I- 1 L 20'-2 3/0 17 -0' ,Stecr/oil/ You: /: O' • -/ 1/ - II 11 f l5�oLt'�aoo 11+ ;- /4: s n----•---r--�.r.............-. _.._I - ///// //// (i,1R c V��Tj SEE DETAR, SHEET UD -01 PROPOSED r TACO 71ME _ 4 3333 - " - BUILDING ;,/4/E33127 W/ C N/ C OQKINQ • // 1 1/ sem' uo--ot 1/ 1/ aoo / /I PITH lARD RIM 3.1.11± 4' IE 331.15 MEZNAJWCAL ROOM SW MECHANICAL PLANS - 14 a rote 1-6" MJ PUJO EX Off 1741 lfAiSt RP 332 16 12" CONC IE OZIT° ////-- / ' c'! 'efi OPIISED WATER ME7ER • 9 TAPPNO 7E& FL Itie GATE VALVIC FLAW Ze HANGER LEGEND WALL BRACKET APPROVInG AGENCIES 1.4 1 SAMMY SCREWS 20 COACH SCREW ROD Id MACHINE THREAD ROD N TOGGLE BOLT SPRINKLER INFORMATION SYMBOL TEMP MFR _ MODEL TYPE FINISH PAID OCT 10 2011 TUKWILA PI RE' 4 IfigiNnw) aa I ot 47 it 4. q$ / T 4z, 44 44 / Ti* / 4* / 44/ 4ZP • Tr 0:4 / 4k1$. 0 / WASH. STATE CONTRACTOR LIC #CoLUMF1952MG CANOPY INFORMATION COLTIMBL4 FIRE, INC. 1534 ISTAVES , - SEATTLE, WA 98134 206-232-8569 FAX: 206-340-6100 , I IfFR MODEL FINISH BEAM CLAMP & RET TRAP O POWDER DRIVEN STUD EYE ROD p CEILING FLANGE . REVISIONS KWIK BOLT R LONG STRAP FLUSH SHELL s SHORT CLIP Z is -s- 25 Zoe, 11 - 1.1 If /1 ciiRowa Rea SIDE BEAM BRACKET (1158) f,,T I TRAPEZE (SEE DETAIL') STD SIDE BEAM BRACKET ✓ PIPE STAND DRAWN BY /4442. DATE JOB NO. si/40, 134 r. FIRE SPRINKLER #16 FPLR U LL JANITOR ; MEI\, SLC #18 FPLR DRY STORAGE rd OOD P hi KHOCD aEi E I i !KITCHEN M r su 11111111411 ER P E COOLER EX;1 -, SIG1.003 ll0 DINING 27X48 27X48 277148 17111uun1 lum111111111111 0 SIG1-005 C 75CD 27524 27X24 BAR H X48- 8ARIIHT. MM DRIVE-THRU SERVICE OFFICE 0 PARIT 27X48 27X48 27X48 F..E,,,,,,,,w n+.rnscv .s4' AFF ENTRY SIG1.006 i(OCD EOL 4.7K 11 ©. y WP 95CD 75C0 ©. SIG1.007 WP 95CD EOL 4.7K II SIG1 SLC #18 FPLR C 75CD #16FPLRI C 75CD 75CD ©• 30CD Fire Alarm Symbol Legend SYMBOL - DESCRIPTION MODEL NUMBER - 5700 IntelliKnighte Model 5700 Single Loop 5700 FACP 1 2 Mini Module SD500-MIM MM Fs Water Flow Detector 0 Ts Tamper Switch Waterflow ❑F SD500-PS Addressable Pull -Station SD500-PS - - KITCHEN HOOD Ansul Hood nNSUL KHooD 3 M. 75CD 2 Wire HomlStrobe, Standard cd, Red P2R - SR -Strobe Standard SR ;Q 3ocD - - 2 Wire Horn/Strobe, Standard cd, Red, Outdoor P2RK ED-vvp 95CD IN -Duct Smoke Detectors 2 Wire HomlStrobe Ceiling mount, Standard cd, Red PC2R Elle 75CD ® EOL 4.7K 0 Resistor, 4.7K ohm, 114 watt, for IXA R4 O Addressable Photo Smoke Detector SD500-APS SK 5700 30CD MMI IMM SYSTEM INPUTS SYSTEM OUTPUTS Required Fire Safety Control Control Unit Annunciation //7/i /' ( / /f' //4,i/ ico/4:9 jaly 1 /'m / '/ l��/roe C / / £? JCO) l � �','R4* ;:h;'gz /eos /oJ// y/° /��/�° / Cm7� /C71,o I y 0/14, Cm(�/v f4f pJ �� fC a, /of /FfF�F .mao / Ili /�1 a :'� HI m/C 0/ pro/c',`°"o �,o,%o Sm +.`4421',g/1/1/1/§/(F/4 A BCfDIIIE F(G 1 Manual Fire Alarm Boxes • - - 0 - _ - • - 1 2 Smoke Detectors 0 j1 0 2 3 Waterflow ® - - - i - • •. 3 4 Kitchen Hood • - • - - - • ` 4 5 IN -Duct Smoke Detectors • - - • - - - i;41, 5 6 Sprinkler Control Valve - • - - 6 7 Fire Alarm AC Power Failure - • - - 7 8 Fire Alarm System Low Battery - - • - -i 8 9 Open Circuit - - • - - - - ' - 9 10 Ground Fauft - • I O 10 11 Notification Appliance Circuit Short - • - - 6 I 11 MM MM DRAWN BY: ROBERT VAUGHN L & I #VAUGHR*981Q4 SEATTLE FIRE DEPT. #SCPV-042.43 NICET 3 #115522 CITY OF REDMOND-DESIGNER OF RECORD #10-B-113 PROPERTY OF AND ALL RIGHTS RESERVED FIRE PROTECTION INC DATE: 10/032011 I A C D EIF HI OPERATIONAL MATRIX ❑ 11,41:1-..hnut Comment As Noted in Red ❑ Per The A 7.ch2d Letter These plans have been rev e" d by The Tukwila Fire ,ovention Boreau f r c forrrian-e with current City -7indards. :pts _e is s blect to errors and nissions which CI : Ct _ j rr e iol . t:1>>s of adopted :ndards and cfnances_ -,e cesoonsioTty for the iy. F1?y -i•+^ r.- drsi. er. - ,IAgvacy of G'cS°y fes:,:, - ti:�:.; E Cie :.«�Iyn- _a,. Ings after del t,o = c-�:;�:: �� t rTee yI ,�, date will jd a: : j ___ red 'ail require a 'subrrilttaii o revs- d: -a- v;r gs for sib5eg1 ent approval. -mai acceptance is s;5'ect to field test and inspection by ne Tukwila Fir Prevention Bureau. - r By: y 1. ,Ow l►! rc,,o1 Li .0 for A ksv Olo�Pa/�ov * S„sIa(� b�r�L�w- �cLhdtt� Gty.y 06. olid, ca t✓A c;vc�-Y ��v . 44 A-1( i vi -3-1`c,1.• `+y ck cls 1.0 L CO w.yt e4e,l1 170'.1...-V 4 of d Kssc►S 4 . NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the tet- TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address fcr shut- down or restcratioit approv 1. '- "Fi"t ,4 tor Celt ° $ 0,_ _11/04 (( A A K da+4.. kiN0 K i ; ' _ door!' D 191}rn r ♦!II c 1- B 1111111:pi Illr EIRE PROTECTION INC. 1730 Gibson Road Everett WA. 98204 425-290-9600 FIRE ALARM TACO TIME 15037 INTERNATIONAL BLVD. TUKWILA, WA. SIZE FIREPI*021 ML FSCM NO. DWG NO. FA 1.0 REV 1 SCALE /8" = 1' 0" SHEET 6 5 ? 4 3 1 A PAID OCT - 6 2011 TUKWILA FIRE _fir/.3 "221 — anpe-s- wpr. .: DD•L 412.u2' D Range -Sr, High D. Cxvuty la' OD' _ x18 DO- D Naomoom oso-OUz2" =DN 0bw0D,O CDVTUa4)N mD O z omm 22 roz 2z222222zo02o-. Or)r) r) r)DDOOOWr = m r m— o m 0 0 0 0 0 0 0 00 0 c C o 0 m oa s a a z z m m m U SmIO(.NNNNNNNNNNnno CNC.'O.'OAANV1222 C) < 0 n x = m N N N N N N N NN N .ti m m ...... Cc DM mti-nD yr)r rrrrrrrrr r rpppprr70mDrr r m m z rlm H m m m m m m m mm m z z D m0 cloy — m-- — o—q m m m m C r r D2nn ypaaDDDa7.3. 3. CiOo In 2Z yL)L)L)E) r r F CO 20 OaDD NN V1iAV)(4 1V)V)V)NNm—x Dmmm rprr _rp_rr2 2 3,z n0000woowoworrz— z„„ yDn0cyDxxxxxxzxzzmmom r0 x y000—'-mf~'12 zD Dr, Nymm7ncmmmmErOmrrlO'riiC DDI 1 IOOoomxz rmKK- KKKKKK,p1J mi OOODaDpr rrrrr aaaaaaaaaa vlJ x Me 2mcfr'11' 0mmzx 4)4)4)WW4)4)(.)4)4)Vv mo ol ~ti -.0 �aa4)a4)4)tJ4)4) ....pm D —Nw.00maow0s N4).L — 0 Dr z L. MOM., m 3 O 1 1 1 1 1 1 1 2 ND 4•1— 22N33( V -e v Dm—aDmr—m Nr pya?xrarpmra z Z Ai _; D D= O On K— z-zZE tim MaN(1N`Om41OmI m XiZrn X- O �Zr ZrrprO C)�nm0P1OOppI�^j gal"' Xp(ANr ..-- rr V1-0,0M6C r"rZ 1.'Dti aOZ� EDL rm z2'ir 22 K 00 2 m x p r r yz CIM -..mm2 P~1N m 20mr1 ,iN o, Om", 2m CP P.m`� f'1 z m p 2 ;;c2 ` i 3.oa r-1 • CN toy Or 113 X— <a-1-. mm P1p0 Oo r. -, , mtv .-, mi., KK miV. ., yr) do ~ my �oz r 0 <NA OrOm yo . N mr^ O 0 0 0 33VJdrIS ONI)IOOD 3H1 Nola - Fire Systems - Parts List Report Page 1 of 2 Fire System Parts List Job # 1345542 - Taco Time -Tukwila -Final Location: AUBURN, WA Fire System # 1 Ansul R102 ANSUL-3.0/1.5 Tag: Installed: Fire Cabinet Right Hood #1 Hoods Covered: Hood # 1 Gas Valve(s): Mechanical 2.000" Supplied by Captive Aire Systems Ship with Hood Supplied by Ship Qty Item CAS # Vendor # Description Dist CAS Units Inst Loose 1 0 43-15733 43-15733 AIR CYLINDER ASSEMBLY - Air Cylinder and Tubing for 1 0 EACH Mechanical Gas Valves (Ansul) 1 1 AT - 1.5 AT - 1.5 TANK(#1A) - 1.5 Gallon SS Tank (for use with 0 1 EACH Automan Release, Actuator, or SS Enclosure (UL/ULC)) 1 1 AT - 3.0 AT - 3.0 TANK(#1B) - 3.0 Gallon SS Tank (for use with 0 1 EACH Automan Release, Actuator, or SS Enclosure (UL/ULC)) 1 3 ANS -OEM ANS -OEM REGULATED RELEASE - Ansul Regulated Mechanical 0 1 EACH Release/Bracket Assembly, OEM, R-102 1 5 LIQ -3.0 79372 AGENT - Ansulex Low PH Wet Chemical Agent, 3 Gallon (UL) 1 0 EACH 1 6 LIQ -1.5 79694 AGENT - Ansulex Low PH Wet Chemical Agent, 1.5 1 0 EACH Gallon (UL) 1 9 101-30 101-30 CARTRIDGE - Carbon Dioxide, 101-30, Double Tank 1 0 EACH Cartridge (R-102) 1 10 TLINK TLINK LINK - Test Link Package 1 0 EACH 1 11 MICRO -SDA MICRO -SDA MICROSWITCH - Single Dual Electric Switch, One 0 1 EACH Standard Switch, One Alarm Duty Switch 1 12 HOSE 79007 HOSE - Rubber Hose 0 1 EACH 1 13 419337 419337 NOZZLE - 2W Nozzle, Duct 0 1 EACH 4 16 419335 419335 NOZZLE - 1N Nozzle, Plenum/Appliance 0 4 EACH 3 19 419338 419338 NOZZLE - 3N Nozzle, Appliance 0 3 EACH 2 25 418569 418569 NOZZLE ADAPTOR - Swivel Nozzle Adaptor 0 2 EACH 8 26 QSA-3/8 QSA-3/8 QUIK SEAL - 3/8" (UL) 0 8 EACH 1 27 QPSA-1/2 QPSA-1/2 PULLEY SEAL - 1/2" Hood Seal (UL) 0 1 EACH 6 28 S -DET S -DET DETECTOR - Series (Scissor Linkage) 0 6 EACH NEW#435547/435548 (OLD#417369/434480) 2 29 ANS-360FL ANS-360FL FUSIBLE LINK - 360deg F, R-102 and PIRANHA 0 2 EACH 4 30 ANS-500FL ANS-500FL FUSIBLE LINK - 500deg F, R-102 and PIRANHA 0 4 EACH 1 34 RPS -A RPS -A REMOTE PULL STATION - Aluminum (without wire 0 1 EACH rope) 2 35 PE -LT PE -LT PULLEY ELBOW - Low Temp. Pulley Elbow, Set Screw 0 2 EACH Type 1 36 PE -HT PE -HT PULLEY ELBOW - High Temp Pulley Elbow, 0 1 EACH Compression Type 3 41 SN -CHAR SN -CHAR SINGLE NOZZLE EXTENDED DROP ASSY 0 3 EACH 2 41 SN-CHAR30 DROPEXT-02 Extended Nozzle Drop -30" 0 2 EACH http://app 1.captiveaire.com/Order/FireSystems/PartsListReport.aspx?JobFireSystemld=3... 1 0/28/201 1 SECTION IV SYSTEly1 DESIGN - UL'E. "170... ULC CEx747 •:Page 4-28 HEV.5 4-1-06 Nome Application Chart The -following chart Lias been. developed to'assist'in calculating the: quantity and type of iioale required to protect each duct,` plenum; or appliance = - , ,- NOTICE:: ,:: This chart is for gerreralreference only= complete detafsfor each type of hazard: _:; Hazard Duct orTransition (Single Nozzle) Duct or Transition (Single Note) Duct or Transition (Dual Nozzle) Electrostatic. Precipitator' (At Base of.Duct) Plenum • (Horizontal. Protection) Plenum (Horizontal Protection) Plenum ' • (Verti6a1 Protection) Fryer (Split or Non-Spfd Vat) Fryer (Split or Non-Sprit,Vat) Fryer (Spiitlor .Non -Split Vat)' Maximum Hardin Dirnensioris Length - iUnlmited - ... . Perimeter0 - 5in: 1127 cm Diameter: -16. : (406 cm Length tlniimiied' - Perimeter .100 (254 cm) Diameter Length:.-ilnfrnited Perimeters=:150 in: (381 cm) r31,4irrt(`r_' lndivtdual Cell:.: . i_ength-1D it (3:1 in) -Length =6 fi..0:8 m} :: • Width — 4 ft.(7:2 Lsngtii 4•ft.t1.:2`m), •Width -4 ft (1:2 m) • . Mazimurn• Size: (witilout'drip boai> _ ".. • 14in:(36cm}z. 15 in_ (38 cm) • Low Pn�dmity• .Maximtirm:Size (wittiout• .dnp board) :14-1/2`io:-(37 cm) x•'' 14 in. (38cm)::` Medium: Proximity" Maximurii Size- (wilhocif drip. -.board) l5 in:•(38 cm): x. High Proximity Mediurri.Prozi Maximum .S'¢e' . jwithoirt drp:boi .19 l/2`iri(49:5 cm) Nigh Proxtrniiy.:; Low:Proxiiniiy Maximum Size:-::. (wrfiiouf drip board) 18:in (45:7.cin) x18 tri: (45.7 cm).. High Proximity' Fryer (Non:Sprit Vat Drily) For muliiple name protan of single fryers see detailed nformaton on Pages 4-l2ihrough 4-14: • 25 — 35 in_' • • 04-89 cm) 419338 Nozzre Tip Stamping= Flow No. i 1W 2W : 2W 1/2N 1N 1W 1W 114' 290 '290 230 245 3N 290 3N Nozzle Application Hazard Fryer (Non -Split Vat Only)* Fryer (Split or Non -Split Vat) • Fryer (Split or Non -Sprit Vat) Range Chart (Contintiea) Maximum Hazard • Dimensin MaximumSize (witl;r,drip board): .21 in; (53 Crax (3q Oin) (Fry Pot must not exceed 15 in- X.14 - (38 c.rn X 36 CM)) 2 High Proximity Medium Proximity ; Maxtrnurn Size (with-drip'boara): „ 253/9 in. (64.4 CM): i19 1/2 in449-.6 Oh) (Fry pot side mist not exceed 1.9 1I2-::. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 rage 4-29 4-1 -06 RSV Minimum Nozzle Qt_ia_mn Heiahts High proximity. -Low prodmity•-, • Maxirnum Size (with drip board) 18 tn. (45.7 cm) : 27 3/4 in. (70.5 Oin) •••„ High Proximity •• • 277- 47 in. . 13 - Maximum (Wittl drip baird)• 14 iri. (3s cm) ?e:. , -s 21 in:.(qtrr.i)*:....: LowProximity . Makirtium-Slie • - (with drip - ' .26 1!211-..(67.CM) ; 1 Medium Proximity' • • . • Longest Side 1 32 in..(8-1 crn) - Area - 384 • (2477 Sq. crn) • ;•• .Longest. Side 28 in: (71 cin)- , • Area -.336 sq.'in, (2168 sq. crri) • Longest Side (High Proximit,A 28 in.:(71crp) Area .7672 sq: in_ • ' sqcm) • • • . Longest Side (Medium Proximity) 1 32:in. (8.16,m) , - Area 768 sq, in. (4955 sq. cm) Longest SidelLow Proxirnity) 36 ip. (91 crp) . Area - 1008 sq. in. (6503 sq. cm) For multiple no=fe protection of single fryers, see detailed inforaation on Pages 4-7 through 4-11. Nozzle Part No 419339 .419340 • (64-p9 crit) • 16 in. (337- 41 cm) 1--16 -7 27 in, - ,(41.--69 cm) 40 , - 176 162 cm) - , • • ' Nozzle Tip Stamping - Flow No 230 245 :419338 3N 419342 '419338 290 3N 419342 • 290 419342 29°1 • 1 419335 40 - 48 in. 419333 (102 -.122 Cm) With b.0.0'Ssh-!tf) • , . .40 5Diit : .419340 127 *ern) • •419341 • „.30 40 in. - (76 -- 192 cm) t • - • 15 - 20in. (38 51 orb) 419342 1N 1F 245 260 290 p.ssembly (3.0 gallon -Part No. 79290 or 1.5 gallbn Pan No. 7291) contains the ra,,,ulated mechanitrn, eoeni tan. exp: .ant gas hose for -agent tank hookup. and -enclosure knockouts to facilitate instillinaadtuaticr, .piping; expellant picino; detection system; and additional equipment. ThiS reOu- fated release assembly is. used in sinole, double.. and multiple - tank systems and :must be mounted to a rigid -surface. The. release mechanism can baused to interconnect both the actu- ation and expellant gas lines it required per system desibri. The regulator is desioned to allow a constant flpw of gas into the tank at 100 psi, (690 kPa.) when the system iscon,ects In sng1e e• . • • ..... .• . • • • • doubles, and miiitiple-tanksyster.4;• tneproyidedexpEl-. lant Gas hose connects the :anent tarik.lb the bottorif outlet of , the regulator. In double.incmtiltipleztank system cOnfigUtatians._ "- the back outlet of the regulator is used as an exPellant oa.s feed • for one additional tankiefosure or tank -bracket :hbOkUP. The • enClosure contains the required knockoUts.to facilitate.this'cOn,, nection. If a pressure switch is to beattached to the regulator . •• additional fittings are reOUired. • : . :•-•: • •••• • • 'H:; • The tank, is mOunted within the encloture. The ;tank contains an adaptor/tube assembly with a burst disc The burst disc • • helps prevent siphoningof the agent.uP the PiPedue.tb cant temperature fluctuations in the„..area•-where- the,tankjs:•:: located. The tank is mild steel and under normal conditions requires hydrcisfatic testirig:..every twelve years. , •• •••• •: • The agent tank is shipped uncharged and -Mus tbe--:filled with 1.53 gallons(S.8 L) or 3.06 gallons (11.5 !.) of -only POSt11,EX Low pH Liquid Fire SUPpressant during installation-.::••:••• ARM Hi 'EMU R-102 RESTAURANT FIRE SUPPRESSION SYSTEM (Standard IA 300Listed) • Thp detertinr eq ,cf design- are connected to -the reiease mechanism..TheenelosUre . contains.knockauts to faCiiitite detection and additional hookups . • The system can be actuated automaticaliy.or .• ; • matic actuation °coifs when a fusible link Within-thedeteCtion ;• system Separates in a 'fire. conditiOn.. Mandel actbatiOns,:of 'the system occurs when personnel otil: on theremote pull . station pull rino. ..s.: •••;•-; •• EXTINGUISHING AGENT . . . ANSULE-X LO‘iv pH Liquid' Fre Suppressant (1 .5. elicin pan . No. 79694 or 3,0 gallon Part No 79372) isa-pdtassiubased solution •deSigned for fast Rnock-down:".and' suppression of grease-related.fires. The agent is shipped. in plastic containers • which provide onecomplete tank Agenl tc:i17.496:1Ifer expectancy is twelve years, The distributor rriListiacordtnetiatth numbers and date of shipnient receipttd be filed with eachinstal- lation record. -Total i Tank • Row No • :0Liantitv System •.:•...-, ": Type of Hardware 1-5 ; 1 Sinale : :: '‘: 1.5 GaIT:•fleg. Releat e . , •: _ 6-11 ' 1 Single 3.0-GaL Aeg.Flefease • Nozzle Icientf ication Chart 'Nozzle .1Nozzle e Part No'. • Stamoina .1W Nole 419336 11W _ . • .1WSS.N5uie 417333 1W • • ••. N Nozzle 419335 11N .• • -INSS•Naz-7_1e. 417332 11N . . . . . • 112N Nozzle 419334 .1/2N 3N. Noule 419338 13N Noz Roy 1 1 1 1 1/2 3 2W No=e 412337 I 2W 2 . , • 2.1/04 Nole 78078 2WH • • . 2 • . ELECTRICAL SWITCHES ;-71...0.c.sellp .10..aci.l.::.pi#. The electrical Switchare intended for lise'Witi-..Ci.ctrid 9s"*. •• . valves; alarma; coritactOrS, lights, cantractor- sUiSoiieciL,eleotritf:,. power shut.offIdevices and other elePtical•-• deViceS ...that are .... • ' . designed to shift Off Or turn on when thesisierif is actUeited; -. : ' • .:- • . .. • . SWitches are airailable;inlki: One SitvitCh ICrt,.PaLL•1\1623878," -.1 • •-• '.. ''' ::- • .. _, •,..; • •; . - 42388Two Swtion Kit, Part No. 423879, Three SWitch, Kit,Part • :No. : :, . ... ..-, I , '• . . . :_ ' 0 and Four SWiEhICrt; part-No..423881, Eacti..sWitCl-rhas a.:••• ••- _.- :.;* .- • •• ••••* set of single -pole, double'7throw contacis.rated at 2'f artiO; 1 Fii)., ..-'. . wil6k.) :-.66.7:1,))1-1 provided wtth each kit. 125, 250, 277 VAC or 2 Hp, 250,277 VAC. MOunting•halbW•are is • 230 NOmie 419339 •"245N�zIe 419340 260Nozzle 419341 290 Nozzle 419342 2120 Nozzle 419343 • 1F NOZzld.• 419333 Hob 1401i..11 j .0012 : : • • li`tItl19011 • • Cgrtridoa-Fleatiired LT 20-R (7032) • LT -3013•• (5373) :5-4-1N7 4451-Pqs /.\ N:c 6tic SAkri5 Gh- : FoCi3a?-; (.01-S) 1-inD 511,0T Drjp. 7: "S-C--f\rilL.- IS S5,k; I • • 230 2 245 2 260 2 290 2120 2 1F 1 1190 1 Carbon Diamide Cartridoe Reouired 101-10 (15850) 101-20 (17499) . • .• • -• ' • • • • SECTION IX = APPENDIX UL EX. 3470 ULC CEx747 Page 9-1 10-1-02 REV.5 SYSTEM SELECTION GUIDE Note: System options do not cover all conceivable variations. They are listed here as a general guideline to show the most common type arrangement for multiple systems, Based on certain system designs utilizing manifolding, non-man'ffolding, 3 -tank systems, etc., other tank/cartridge combinations can be designed. The combinations below are based on 11 flow, 3.0 gallon tanks and 5 flow, 1.5 gallon tanks. More competitive designs may be available by utilizing 12 flow and 6 flow systems when appropriate. Total Tank Type of Carbon Dioxide Nitrogen ' Flow No.* Quantity System Tvpe of Hardware Cartridge Required Cartridge Required 1-5 1 Single 1.5 Gal. Reg. Release 101-10 (423439) LT -20-R (423429) 6-11 1 Single 3.0 Gal. Reg. Release 101-20 (423441) LT 30-R (423435) 12-16 2 Double 1.5 Gal. Reg. Release 101-30 (423443) Double (423493) 3.0 Gal. Additional Tank 17-22 2 Double 3.0 Gal. Reg. Release 101-30 (423443)** Double (423493) 3.0 Gal. Additional Tank 23-33 3 Multiple 3.0 Gal. Reg. Release 101-20 (423441) LT -30-R (423435) 3.0 Gal. Reg. Actuator 101-30 (423443)*** LT -A-101-30 (423491) 3.0 Gal. Additional Tank 23-27 3 Multiple 1.5 Gal. Reg. Release 101-10 (423439) LT -20-R (423429) (Optional) 3.0 Gal. Reg. Actuator 101-30 (423443)*** LT -A-101-30 (423491) 3.0 Gal. Additional Tank 28-33 3 Multiple 3.0 Gal. Reg. Release N/A Double (423493) (Optional) (2) 3.0 Gal. Additional Tanks 34-38 4 Multiple 1.5 Gal. Reg. Release 101-10 (423439) LT -20-R (423435) 3.0 Gal. Reg. Actuator N/A LTA -101-30 (423491) Double 3.0 Gal. Tank Box 34-38 4 Multiple 1.5 Gal. Reg. Release 101-30 (423443) Double (423493) (Optional) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)*** LT -A-101-30 (423491) 3.0 Gal. Additional Tank 39-44 4 Multiple 3.0 Gal. Reg. Release 101-20 (423441) LT -30-R (423435) 3.0 gal. Reg. Actuator N/A LTA -101-30 (423491) Double 3.0 Gal. Tank Box 39-44 4 Multiple 3.0 Gal. Reg. Release 101-30 (423443)"* Double (423493) (Optional) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)'** LT -A-101-30 (423491) 3.0 Gal. Additional Tank 45-49 5 Multiple 1.5 Gal. Reg. Release 101-30 (423443) Double (423493) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator N/A LT -A-101-30 (423491) Double 3.0 Gal. Tank Box 45-49 5 Multiple 1.5 Gal. Reg. Release 101-10 (423439) LT -20-R (423429) (Optional) 3.0 Gal. Reg. Actuator 101-30 (423443)*** LT -A-101-30 (423491) 3.0 Gal. Additional Tank 3.0 Gal. Reg. Actuator 101-30 (423443)*** LT -A-101-30 (423491) 3.0 Gal. Additional Tank Eased an 5 flow numbers for a 1.5 gal. system and 11 flow numbers for a 3.0 gal. system. If tanks are maniiolded, only a "double tank° nitrogen cartridge (Part No. 423493) can be used. 9 tanks are manifolded, either an LT -A-101-30 nitrogen cartridge (Part No. 423491) or a double tank cartridge (Part No. 423493) can be used. T 17"r;t7 74) CCI ❑ Without Comments ❑ As Noted in Red ' Per The Attached Letter hese plans have been reviewed by The Tukwila Fire iention Bureau for conformance with current City ndsr'Js. AcCeotanC: is subject to errors and which do rot authorize violations of adopted •“c'aros and ordindre ,s• The resborsibliity for the ,lacy of des c't cotaity w to ti:e designer. ' ons, �iei` 'U+ ` s. : s r•y�OR; to the drawings after t i?r� wU Visit i, ' . cuptance and will require a •.r•I:iit:Ti�t o. f rev sryti Drawings orxt;uos•tquent approval. .. ral acceptance is sub)ert to Field test and inspection by rte Tukwila Fire Prevention Bureau. 'ate: 1"2-J f By: c)/I TUKWIL t FIE DEPAR i ;' NT Please c•:,41236 -1:75 -4 -VN and give this Fire P :e iTlmft No. and exact address for shut- down or rest s atio€i r ?p; oovaI.