Loading...
HomeMy WebLinkAboutPP - 17305 SOUTHCENTER PKWY #140 - LA Z BOY FURNITURE GALLERIES - PERMITS AND PLANS17305 SOUTHCENTER PKWY #140 ASSOCIATED PERMITS 07-S-266 F22-0069 WASHINGTON SURVEYING AND RATING BUREAU 2101 4TH AVENUE, SUITE 300 SEATTLE, WA 98121 Jose A. Buitrago Senior Field Representative::Plan Review jose.buitragoC wsrb.com (206)-273-7157 November 20, 2007 PLAN SHEETS 1- of 1 SUBJECT Lazy Boy — Tenant Improvement 17305 — Southcenter Parkway Tukwila, Washington t• The attached plans have been reviewed as follows: The following revisions or additions to the design as shown would qualify the protection for improved rates based upon information shown on these plans. Completed copies of the Contractor's Material and Test Certificates for both the overhead and underground piping should be submitted to this Bureau, including tests of the local alarm and main water supply test pipe (2 -inch). All piping, valves, and fittings should be listed and labeled by UL for fire service and installed, tested, and flushed in accordance with NFPA standards. A minimum temperature of 40°F must be maintained with a thermostatically controlled heating system in all areas containing wet pipe sprinkler equipment. 1. Hangers should be installed according to UL listing and as specified by NFPA 13. 2. Extend sprinkler protection to all areas including exterior eaves, soffits, canopies, combustible blind and roof spaces, and to roof skylights. L, t'� v2 etf ecl n- i; tO teia-t 0 Serving the Property aha CasuayCif°1nsurpdpevgAl`•ri`Itpihttoe 9q�,pAelc9ti1 ces te, as _ .�hettteC _.��na� FIRE MARSHAL'S OFFICE SERVICE AUTHORIZATION FORM Name: PH #: Email: CONTACT INFORMATION Kyle Bennett (253) 290-3265 kyle@cascadealarm.com Company Name: Cascade Alarm Permit #: Project or Job Name: Project Location: PERMIT INFORMATION F22-0069 La -Z -Boy Home Furnishings 17305 SOUTHCENTER PKWY COMPLEX SELECT THE AFTERHOURS OR EXPEDITED SERVICE THAT IS NEEDED (X) FIRE INSPECTION FIRE PLAN REVIEW 0 The undersigned, as an authorized representative of the above company, hereby agrees to pay $500 for the afterhours or expedited service. Signature: Pete Digitally signed by Pete Stokesberry Stokesberry Date: 2022.05.10 16:24:47 -07'00' Printed Name: Peter Stokesberry Receipt / Transaction#: FMO 2021 City Use Only Date: 05/10/2022 Payment Date: April 6, 2007 Sprinkler 83a VIKING TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE ORDINARY HAZARD ELO SPRINKLERS The Viking Corporation, 210 N industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464, Fax: 269-9454495 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking EC/QREC Ordinary Hazard Extra -Large Orifice Sprinklers VK532 and VK534 are thermosensitive spray sprinklers available in several different finishes and temperature ratings to meet varying design requirements. The extra -large orifice produces the flows required to meet Ordinary Hazard density requirements at lower pressures than standard orifice or large orifice sprinklers. The special deflector is de- signed to meet Ordinary -Hazard density requirements for specifically listed extended areas of coverage when the required minimum water supply is provided at the sprin- kler, Upright Sprinkler VK532 is UL Listed and FM Approved as standard response; Pendent Sprinkler VK534 is UL Listed as standard response and quick response. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, the Polyester and Teflon° finishes are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Polyester or Teflon®coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2022 NYC Approved: MEA 89-92-E, Volume 9 Refer to the Approval Chart on page 83d and Design Criteria on page 83e for cULus Listing and FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically to 500 psi (34.5 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4" (20 mm) NPT Nominal K -Factor: 11.2 U.S. (161.3 metrict) tMetric K -factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K -factor shown by 10.0. Glass -bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Part No. 08687: 2-5/16 (59 mm) Part No. 08340: 2-3/8° (61 mm) Viking Technical Data may be found on The Viking Corporation's Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Brass UNS-C26000 for Sprinkler 08340. Copper UNS-C19500 for Sprinkler 08687 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Teflon° Coated Sprinklers: Belleville Spring -Exposed, Screw -Nickel Plated, Pip Cap -Teflon° Coated For Polyester Coated Sprinklers: Belleville Spring -Exposed Ordering Information: (Also refer to the current Viking price•list:) Order EC/QREC Ordinary Hazard Extra -Large Orifice Sprinklers VK532 and VK534 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloye = F, White Polyester = M -/W, Black Polyester = M -/B, and Black Teflon° = N Temperature Suffix (°F/°C): 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286-/141° = G For example, sprinkler VK532 with a Brass finish and a 155 °F/68 -C temperature rating = Part No. 08687AB Form No. F_051393 Replaces page 83a -c, dated June 28, 2006 (Reformatted.) sprinkler 83b April 6, 2007 VIKING TECHNICAL DATA STANDARD/QUICK RESPONS = EXTENDED COVERAGE ORDINARY HAZARD ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 05118CW/B (available since 1981) B. Wrench for recessed pendent sprinkler: Part No. 11663W/B** (available since 2001) **A Y:" ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A (available since 1971) B. Twelve -head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION Duringfire conditions, the heat -sensitive liquid in theglass bUlbex `ands, causingtheglass to shatter, releasin thepipcapand q p 9 sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE --Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinklers VK532 and VK534 are available through a nettwork of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 05118CW/8 Figure 2: Upright Sprinkler VK532 April 6, 2007 Sprinker 83c VIKING TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE ORDINARY HAZARD ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES a", ' ,, b\ 7 ,:r w� 'i J�3 . .� a+^r "'- t. .n. \y; ,.r �3aJ E C •' '' # G} GY':i%:.3�.s ✓ i1 Yry ! ,. < � � l �f � t I� i 1 "Crij t � r { , � 1 i ��i ��ii t r 1Y; 1 / R 'rcP f oil { p }YJ i trY� �tl i "1'•� �5 .L ( �. hs.c;„':`$J)ik',tivto rtrx '. r5. Er:,f•'i zEE c C'':�c v . w.. ..vk.P.,.., .....ii F ....,. f�4�JJ'1~J �s t4 tft> .: ,.. . f��liAl �`�9,I����.,.EGCi"c. rw.yy "�!''. {$;ku:u 5 y . } ,� :Y�"?�ra� e r rr. vti x. S 0i fc 1 `�.�:.,j ( O :�Y' Y[ ��F :'SY .�,°.� A{ s; fr.�.;! � >vS . � R �I X �, � un ysa c 1 s rEf.'Ff".S.t4� . �fc {: CR � �i. tr: S�i�F. ,i4 (F r u , - 4.. c �{4, }) 7�i �' S 1 . 7 i....:�, JS y .'f �V 'G 1 � r/ r�.cGti�.c_u9s'x��2f.=,�v`-...t -fz.e.._:.,_..-::i.na�L�.�..m �,.u..3,.=.�.�f.L.l��,���ri Ordinary 155 °F (68 °C) :, ,,,. ,, 100 °F (38 °C) Red Intermediate 175 °F (79.°C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) :,.i;i'. 150 °F (65 °C) High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion -Resistant Coatings3: White Polyester, Black Polyester, and Black Teflon® Footnotes ' The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. For Teflon® coated open sprinklers only, the waterway is coated. Step It Carefully slide the wrench sideways around the deflector and protective shield. (Note the orientation of the shield in the wrench.) Sprinkler Vrench 11663V/9st+! Rust be used for Installing recessed Sprinkler VK534 6 mA 1/2' ratchet Is required (not available from Viking). It Step E' Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats, Figure 3: Wrench 11663W1B for Recessed Pendent Sprinkler VK534 Sprinkler 83d April 6, 2007 TECHNICAL DATA STANDARD/QUICK RESPONS = EXTENDED COVERAGE ORDINARY HAZARD ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464:.. Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Sprinkler Base Part Number' SIN NPT Thread Size • ' . ''Npminal K -Factor Maximum Water Working Pressure Overall Length Inches mm U.S. metric2 Inches mm 08687 Upright VK532 3/4 20 11.2 161.3 175 psi (12 Bar) 2-5/16 59 08340 Pendent VK534 3/4 20 11.2 161.3 2-3/8 61 ‘. Approval Chart EC/QREC Ordinary Hazard ELO Sprinklers � Fin ish erature KEY AIX4-Escutcheon (If applicable) Maximum Sprinkler Spacing (L x Ws) Maximum Area per Sprinkler Minimum Water Supply Requirements' Listings and Approvals' Ordinary Hazard Group I Ordinary Hazard Group 11 Pendent VK534 Upright VK532 Flow / Pressure Flow / Pressure cULus" NYCS cULus" NYC° Standard Response 12 ft. x 12 ft. (3.7 m x 3.7 m) 144 ft2 (13.4 m2) 30 gpm @ 7.2 psi (113.6 L/min @ .50 Bar) 30 gpm @ 7.2 psi (113.6 L/min @ .50 Bar) Pendent Sprinkler VK534 is Listed as QR for 12' x 12' and 14*x 14' areas. (See listings below) Al Al 14ft.x14ft.(4.3mx4.3m) 196 ft2 (18.2 m2) 30 gpm @7.2psi (113.6 L/min @ .50 Bar) 39 gpm @12.1psi (147.7 Umin @ .84 Bar) Al Al 16 ft. x 16 ft. (4.9 m x 4.9 m) z 8 256 ft(23.m2) 38 gpm @ 11.5 psi .d (143.9 Umin @ .79 Bar) 51 gpm @ 20.7 psi (193.1 L/min @ 1.43 Bar) AIX, B1Y AIX, B1Y Al Al 18 ft. x 18 ft. (5.5 m x 5.5 m) 324 ft2 (30.1 m2) 49 gpm @ 19.1 psi (185.5 Umin @ 1.32 Bar) 65 gpm @ 33.7 psi (246.1 L/min @ 2.32 Bel - AIX, B1Y AIX, B1Y Al Al ft. x 20 ft. (6.1 m x 6.1 m) 400 ft2 (37.2 m2) 60 gpm @ 28.7 psi (227.1 Umin @ 1.98 Bar). 80 gpm @ 51.0 psi �.' (302.8 Umin @ 3.52 Bar) AIX, BIY AIX, B1Y Al Al Quick Response Pendent Sprir:lcler VK534 (cULus only) 12 ft. x 12 ft. (3.7 m x 3.7 m) 144 ft2 (13.4 m2) 30 gpm © 7.2 psi (113.6 L/min @ .50 Bar) 39 gpm @ 12.1 psi (10J7 L/min © .84 Bar) AIX ,B1Y - - -- 14 ft. x 14 ft. (4.3 m x 4.3 m) 196 ft2 (18,2 m2) 30 gpm © 7.2 psi (113.6 L/min @ .50 Bar) 39 gpm @ 12.1 psi (147.7 L/min @ .84 Bar) AIX,BIY - -- - FM Approvals - Standard Response Requirements (Upright only): Refer to the Design Criteria section on page 83e, FM Approval (Standard Response) Pendent vK534 Upright VK532 -- A2 12 ft. x 12 ft. (3.7 m x 3.7 m) 144 ft2(13.4 m2) NOTE: FM installation guidelines may differ from cULus and/or NFPA criter _ A2 14 ft. x 14 ft. (4.3 m x 4,3 m) 196 ft2(18.2 m2) - A2 16 ft. x 16 ft. 4.9 m x 4.9 m) 256 ft2(23.8 m2) Approved Temperature Ratings A - 155 °F(68 °C), 175 °F(79 °C , 200 °F(93 °C),and , ) 286 F (141 °C) B - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C 155 °F (68 °C) Approved Finishes 1 - Brass, Chrome-Enloy®, White Poly- ester', Black Polyester', and Black Teflon®' 2 - Brass, Chrome-Enloy®, and White Polyester Approved Escutcheons X - Standard surface -mounted escutcheons or the Micro- fast® Model F-1 Adjustable Escutcheons Y - Standard surface -mounted escutcheons or the Micro - fast® Model F-1 Adjustable Escutcheons, or recessed with the Micromatic® Model E-1 or E-2 Recessed Escutcheon Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K -factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K -factor shown by 10.0. ' This chart shows listings and approvals available at time of printing. Check with the manufacturer for any additional approvals. " cULus Listed for use in the U.S. and Canada. ° Accepted for use, City of New York Department of Buildings, MEA 89-92 Vol. 9. 6 To determine "Minimum Water Supply Requirement" for areas of coverage where length and width of actual sprinkler spacing are not equal, select the "Maximum Sprinkler Spacing" from the chart that is equal to or greater than the larger of the actual spacing (length or width) dimensions used. Example: When using 10'-6" x 13'-0" sprinkler spacing, provide the "Minimum Water SupplyRequirement" listed in the chart for 14'-0" x 14'-0" spacing. For areas of coverage smaller than shown, use the "Minimum Water Supply Requiremertt' iri the appropriate hazard group for the next larger area listed. The distance from sprinklers to walls shall not exceed one-half the "Maximum Sprinkler Spacing" listed for the "Minimum Water Supply Requirement" used. ' cULus Listed as corrosion resistant. 8 The Microfast® Model F-1 Adjustable Escutcheon is considered a surface -mounted escutcheon because it does not allow the fusible element of the sprin- kler to be recessed behind the face of the wall or ceiling. April 6, 2007 Sprinkler 83e VIKING TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE ORDINARY HAZARD ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com }i v '�b i �y?,'1+}..1��, y;rFe�tler�l��",,. ' .a:.,�4�.ttlu'+atf .,•.Wr u i�a 5f7 : .,.._.._ 1 ) a: I� z b�L I��lfv! I L ac��l ` Y 1 f 'lJ 4 ,: ( ;• 'i l\. t `h t ��J f ..it } 11 '(` Y57<5 Y 1 � .{'� dL�.? .fae{t�r ai C"i'-� 1} T �0 '�cY+ka f' nl l� "91 =+r• tri r!1;;o rj-"r `t 3 �.... d.la a oLito ''k„"r t„ 3. S k�`� is S ,y F ..9 r t :t2 n. �_ � . c� tr . c a.._�...._-_? , "'�._�__ .� _!.......3. _..._,...iY:? �. ,.. ,. a .'`f._.�. _ � _:f4.rt.: ...n..t,.i.3:L......,..?i...�...r_...Su3..:to.......1v.i....{...__..__...Ll c....�....�.v.... __.1...1 VS.�t'�... .Xl .. S .t.v .c S:.�.J cULus Listing Reauirements: ECOH-ELO Upright Sprinkler VK532 and Pendent Sprinkler VK534 are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for extended coverage upright and pendent spray sprinklers as indicated below: • The minimum water supplies and maximum areas of coverage shown in the Approval Chart are designed to provide the following design densities: 0.15 gpm/ft2 (6,1 mm/min) for Ordinary -Hazard Group I densities; 0.2 gpm/ft? (8.1 mm/min) for Ordinary -Hazard Group II densities. • The sprinkler installation rules contained in NFPA 13 for extended coverage upright and pendent spray sprinklers must be followed. • Also, Viking ECOH-ELO Upright and Pendent Sprinklers are cULus Listed for use in unobstructed construction, and noncombustible obstructed construction consisting of solid steel and/or concrete beams as defined in the latest edition of NFPA 13. • Ceiling slope not to exceed 2/12 (9.5°). FM Approval Reauirements: ECOH-ELO Upright Sprinkler VK532 is FM Approved as Standard Response for installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins as indicated below: • For limited use in buildings of specific ceiling or roof construction and forahe protection of certain specific ordinary hazard occupancies (non -stor- age and/or non-flammable or non-combustible liquid). - - ; -. ae +i'='` 4{ FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins confain:guidelines relating to, but not limited to: minimum water supply require- ments, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages EC1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size: 2-5/16” (58.7 mm) minimum 2-1/2" (63.5 mm) maximum (42.9 mm) ;;L .1 -1/2" (38.1 mm) Pendent Sprinkler VK534 Installed with a stand'drd:.1%8' (3.1 mm) surface --mounted 'escut!cheon 2" (50.8 mm Maximum 1-1/2" (38.1 mm) Minimum Installed with o Microfast Model F-1 Adjustable Escutcheon Figure 4: Sprinkler VK534 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Sprinkler 83f • 1, • April 6, 2007 VIKING TECHNICAL DATA STANDARD/QUICK RESPONS = EXTENDED COVERAGE ORDINARY HAZARD ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Ceiling Opening Size: 2-5/16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 1-3/4" (44.5 mm) Maximum } 1-1/8" (28.6 mm Minimum Installed with a Micromatic Model E-1 Recessed Escutcheon 2" (51 mm) Maximum 1-1/8" (28.6 mm) Minimum Installed with a Model E-2 Thread—an Recessed Escutcheon Figure 5: Sprinkler VK534 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_051393 Replaces page 83a -c, dated June 28, 2006 (Reformatted.) • 4t'Xixj."' 1 ^ • • vAs.Fi,'1•"criv76:.7.41r4,179Er..:71:745" r * .4:14: 144',/rOZ4 • ',4417:407."1,X10.." ,Avs4,1 woo.: 45. • ••••• " ' a4trx • • • , • ; • ..1;:f • • .• ' • tr.': Index Installation Instructions NFPA 13 Code Language and Seismic Qualification Friction Loss Data and Specifications Product Specification Sheets FM Global: Testing & Approvals Underwriters Laboratot ` esting & Listings 11 Loss Prevention Certification Board: Testing & Certifications 13 CA Office of Statewide Health Planning and Development 15 Other Approvals 17 Limited Warranty 20 1 3 5 7 9 cause personal 7njur istallat�on technicians must read the enure manual prior totattemp stallationtof product Dunng maintenance or inspection of FlexHea' oduct, fac1l1ty fireupratection system MUST BE INACTIVE' DO NOT €TEMPT RELOCATION OR MAINTENANCE WHEN FIRE PROTECTION Installation Instructions S▪ tandard pipe wrench Safety glasses Adjustable wrench Screwdriver Mat' ,.a ,eta;re.-d Sp• rinkler pipe thread sealant Teflon` tape 1. Mounting Bracket Assembly A. For this step you will need a 3/8" bolt, 1/4" bolt, universal hub and mounting bracket. B. Select one of the four sprinkler port locations on mounting bracket. C. Thread the 3/8" bolt through side of universal hub. D. (Photo 1a) Insert tab of universal hub into slot on mounting bracket as shown. E. (Photo 1b) Flip bracket over and insert aiidstigiiten 1/4" attachment bolt thru pre -punched hole in bracket until tight as shown. 2. Attaching Mounting Bracket A. (Photo 2) Attach mounting bracket to T -bar suspended ceiling grid. From above the ceiling, position FlexHead Mounting Bracket legs on to T -bar grid so that the selected hole in support bracket aligns directly above sprinkler head location in ceiling tile. B. Position the two clips at the ends of the support bracket legs on the T -bar grid and push each of the two clips down to snap in place as shown. Be sure the center section of the clip is on the outside of grid and base section is on the inside. NOTE: For additional support, screw self tapping screw through hole in center tab of bracket into grid. 2A. optional Attachment for Mounting Bracket to Metal Studs/Gypsum Board Ceiling A. Flip mounting bracket over and install universal hub on desired sprinkler port location. B. (Photo 2A) From above the ceiling, position mounting bracket over metal studs as shown. Align hole in bracket directly over sprinkler hole prepared in ceiling. Attach mounting bracket to metal studs by screwing two 1/4" self -tapping screws through bracket into grid. C. Repeat process on opposite end of bracket. Both ends of bracket should be attached with two self -tapping screws. 3. Connect FlexHead Sprinkler Drop to Sprinkler Branch Line A. Apply Teflon tape and pipe sealant to one inch (1") threaded end of FlexHead sprinkler drop per NFPA guidelines. B. Attach one inch (1") threaded end dfFlex.Flead Sprinkler Drop to branch line per NFPA, state!and local code guidelines. C. (Photo 3) Do not use welded or braided hose section of FlexHead sprinkler drop for a wrenching surface. Attach FlexHead sprinkler drop using rigid pipe end of units as wrenching surface as shown. 4. Secure FlexHead Sprinkler Drop to Mounting Bracket and Attach Sprinkler Head. A. (Photo 4a) Bend the FlexHead to hold`its°:desirbd position. The FlexHead sprinkler drop has`a`7"! minimum bend radius per FM guidelines and 3" minimum bend radius per UL guidelines. Insert outlet fitting end of FlexHead sprinkler drop through center hole in previously installed mounting bracket and hole in ceiling tile. Make sure the hose is bent sufficiently so that the reducing coupling sits perfectly vertical in center hole of support bracket. Do not torque or twist FlexHead during installation process. B. (Photo 48) Attach sprinkler head, properly prepared with Teflon tape and sealant to FlexHead sprinkler drop according to NFPA and sprinkler head manufacturer's guidelines. C. (Photo 4C) Adjust FlexHead sprinkler drop height to accommodate type of sprinkler head. When sprinkler head is in desired location, tighten the fastening bolt on center hub of support bracket by turning clockwise with wrench until tight as shown. 5. Completing Installation A. Test installation of sprinkler system for any leaks per NFPA guidelines. B. Install sprinkler escutcheon from below ceiling per manufacturer's guidelines. These connections are designed for use in ceilings with grids that meet ASTM C 635 (Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay -in Panel Ceilings) and ASTM C 636 (Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay -in Panels) referenced by the IBC. The three structural classifications are the following: Light -Duty Systems, Intermediate -Duty Systems and Heavy -Duty Systems. These connections have been approved for use in all Intermediate - Duty and Heavy -Duty structural classifications. NFPA 13 Code Language and Seismic Qualification NFPA 13 Standard for Installation of Sprinkler Systems 2007 Edition 9.2.1.3.3* Flexible Sprinkler Hose Fittings. A. 9.2.1.3.3 Examples of areas of use include clean rooms, suspended ceilings, and exhaust ducts. 9.2.1.3.3.1 Listed flexible sprinkler hose fittings and its anchoring components, intended for use in installations connecting the sprinkler piping to sprinklers, shall be installed in accordance with the requirements of the listing including any installation instructions. 9.2.1.3.3.2 When installed and supported by suspended ceilings, the ceiling shall meet ASTM C-635and shall be installed in accordance with ASTM C-636. 9.2.1.3.3.3* When flexible sprinkler hose fittings exceed 6 ft in length and are supported by a suspended ceiling a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft. A. 9.2.1.3.3.3 The committee evaluation of flexible sprinkler hose fittings supported by suspended ceilings was based upon a comparison of the weight of a 6 ft, 1 in diameter sch 40 water -filled flexible hose fitting weighing approximately 9 lbs. The information provided to the committee showed that the maximum load shed to the suspended ceiling by the flexible hose fitting was approximately 6 lbs and that a suspended ceiling meeting ASTM C-635, Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension of Acoustical Tile and Lay -In Panel Celings, and installed in accordance with ASTM C-636, Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay -In Panels, can substanciaLly support the load. In addition, the supporting material showed that the flexible hose connection can be attached to the suspended ceilings because it allows,the necessary,deflections under seismic conditions. FlexHead Suspended Ceiling Detail. Ceiling grid mounting bracket FlexHead sprinkler drop Adjustable hub Sprinkler branch line Suspended t -bar grid Each FM approved, UL listed, LPCB certified unit is ready to install, pressure- and leak -tested, and comes complete with a flexible stainless steel hose and mounting bracket with adjustable hub. Sprinkler head (not included) Ceiling tile FlexHead Sheetrock Ceiling Detail. Sprinkler branch line Self -tapping screw typ. 2 FlexHead sprinkler drop Adjustable hub Metal stud mounting bracket Metal stud Sheetrock ceiling Sprinkler head (not included) Hose Specification Sheet A Regular Model 1 inch NPT threads to ANSI B1.20.1 Typ. 304 SS Sch. 40 Pipe Weld per ANSI/AWS 82.1-00 Typ. 304 SS Braid Sleeve 1 ' • :-yp. 304 SS Corrugated Hose 1 inch true -bore internal diameter provides lower friction loss Elbow Model Typ. 304 SS Braid to prevent elongation and improve pressure retention Weld per ANSI/AWS B2.1-00 Typ. 304 SS , Typ. 304 SS outlet spud 1/2 & 3/4 MO female NPT threads to ANSI 81.20.1 Nikrg-prem ;;‘'itrairm ,!,: Look maw roof: : 2024 24 3 4.5 6.75 2036 36 3 4.5 6.75 2048 48 3 4.5 6.75 2060 60 3 4.5 6.75 2072 72 3 4.5 6.75 cJ D T B A Bracket Specification Sheet Multiport Design (For use with T -bar grid and metal stud applications) 24" 6" S (4) 2.50" Adjustable Design (For use with T -bar grid, metal stud, and Chicago grid applications): standard sizes are 16" and 24" long 16"/24" - 0.290" 3.298" 1 1.500 2.33"/5"-. 7.74"/15.75" 2.55"-. ❑0 2.33"/5" 2.375" 1.135" , 4 6" 2.50" 2.60" 1 6" 3" 5"-- —3" – 6" S (4) 2.50" Adjustable Design (For use with T -bar grid, metal stud, and Chicago grid applications): standard sizes are 16" and 24" long 16"/24" - 0.290" 3.298" 1 1.500 2.33"/5"-. 7.74"/15.75" 2.55"-. ❑0 2.33"/5" 2.375" 1.135" , 4 6" 2.50" 2.60" 1 FlexHead® Flexible Sprinkler Connections Satisfy New Seismic Code Requirements Background of New Code Requirements: More than 900/0 of the states in the U.S. are adopting the International Building Code (IBC) that address, among other things, the installation of fire sprinkler systems in seismic zones. The code is intended to neutralize the probability of fire sprinkler systems being damaged and made inoperable by seismic activity, including ceiling movement than can shear sprinkler heads and/or disrupt the integrity of arm -over connections from the branch lines. The IBC Code and Sprinkler Design in Suspended Ceilings: The latest version of the IBC defers to ASCE 7 for the sprinkler/ceiling design in Seismic Design Categories 9SDC) C and D, E & F. In Seismic Design Category C, suspended ceilings are to be designed and installed in accordance with Ceilings & Interior Systems Construction Association (CISCA) recommendations for Zones 0-2; and sprinkler heads and other penetrations shall have a minimum of 1/4 - inch clearance on all sides. In Seismic Design Categories D, E & F, suspended ceilings are to be designed and installed in accordance with CISCA recommendations for seismic Zones 3 and 4 with some additional requirements. Except where rigid braces are used to limit lateral deflections, sprinklerheads-and other penetrations shall have a 2 -inch oversized ring,, sleeve, or adaptor through the ceiling to allow for free movement of at least 1 inch of ceiling movement in alt horizontal directions. Flexible Sprinkler Connections Exceed IBC Code Requirements: Flexible sprinkler connection provide characteristics that exceed the most stringent seismic code requirements. The flexibility of the hose allows Typically, each unit consists of a threaded pipe nipple ,for. connecting to the 'main:4r• branch '`"feaderLine, a flexible hose:i,n • standard lengths, a: reducing fittings.. :that"the sprinkler; head: attaches to„:'.' and a mounting b;racket: Pipe nipple Sprinkler branchline • Rexible.connecting'hose in standard ; lengths —allows the head to more in • • .. any:direction during a seismic event;, { ,,without causing damage.to the ;:'sprinkler system Reducing fitting Sprinkler head, • FlexHead Industries recently satisfactorily completed full-scale seismic qualification testing at the Structural Engineering Earthquake Simulation Laboratory located at SUNY, University at Buffalo. Tests were conducted using the International Code Council (ICC) acceptance criteria "ICC -ES AC -156 Seismic Qualification Testing of Nonstructural Components'. TMs is the first time a sprinkler component has been seismically certi- fied using test criteria accepted by the ICC. the head to move with the ceiling in any direction during a seismic event without causing damage to the sprinkler system. FlexHead Industries recently satisfactorily completed full-scale seismic qualification testing at the Structural engineering Earthquake Simulation Laboratory located at the University of Buffalo using the International Code Council (ICC) testing standard "ICC AC -156 Seismic Qualification Testing of Nonstructural Components': This is the first time a sprinkler component has been seismically certified using test criteria accepted by the IBC. FtexHeads were installed in suspended ceilings meeting the code requirements for Seismic Design Category C and Seismic Design Categories D, E & F and were subjected to the highest accelerations determined for each Seismic Design Category. No damage to the fire sprinkler system or suspended ceiling system was observed, and the sprinkler heads remained in their intended location during all of the test performed. Friction Loss Data and Specifications FLexHead Internal Outlet Hose Assembly Model It Diameter Size Length ft(m) True -Bore 2024 1 in 1/2 in. 2 ft (0.6 m) 2036 1 in 1/2 in. 3 ft (0:9 m) 2048 1 in 1/2 in. 4 ft (1.2;m) 2060 2072 1 in 1/2 in. 5 ft (1.5 m) 1 in 1/2 in. 6 ft (1.8 m) 2024 1 in 3/4 in. 2 ft (0.6 m) 2036 1 in 3/4 in. 3 ft (0.9 m) 2048 1 in 3/4 in. 4 ft (1.2 m) 2060 1 in 3/4 in. 5 ft (1.5 m) 2072 1 in 3/4 in. 6 ft (1.8 m) Equivalent Length of 1" Maximum Rated schedule 40 pipe Pressure FM Approval/UL Listing 3.5 ft (1.1 m)/17 ft (5.1 m)* 175 psi (1205 kPa) 4.8 ft (1.5 m)/22 ft (6.6 m)* 175 psi (1205 kPa) 6.8 ft (2.1 m)/24 ft (7.3 m)* 175 psi (1205 kPa) 8.5 ft (2.6 m)/25 ft (7.5 m)* 175 psi (1205 kPa) 8.9 ft (2.7 m)/28 ft (8.4 m)* 175 psi (1205 kPa) 7.8 ft (2.4 m)/9 ft (2.7 m)* 175 psi (1205 kPa) 175 psi (1205 kPa) 175 psi (1205 kPa) 175 psi (1205 kPa) 175 psi (1205 kPa) 8.1 ft (2.5 m)/16 ft (4.8 m)* 17.9 ft (5.4 m)/21 ft (6.4 m)* 19.9 ft (6.1 m)/22 ft (6.6 m)* 24.3 ft (7.4 m)/25 ft (7.5 m)* FlexHead products are intended for use in hydraulically designed wet, pre -action, deluge or dry pipe sprinkler connections per NFPA 13, 13R, and 13D guidelines. The hydraulic loss of the FlexHead connector needs to be included in the hydraulic design calculations the same as a valve or fitting. Each FlexHead sprinkler drop has a 3" minimum bend radius per UL guidelines, and a 7" minimum bend radius per FM guidelines. * Equivalent lengths are shown with 3 bends. Different values were obtained by FM and UL due to the differences in minimum bend radius, testing protocol and calculation methods. Please see individual testing standards for more information relative to friction loss (Equivalent Length of Pipe). System Specifications Sprinkler system final connections in commercial.. ceilings shall be FlexHead model number as manufactured by FlexHead Industries Inc.,* Holliston, MA USA (800) 829-6975 or (508) 893-9596, fax (508) 893-6020 as approved by Factory Mutual Research Corporation and Underwriters Laboratories. Each FlexHead system includes ceiling mounting bracket with hardware and welded, teak -tested 1" braided FlexHead Flexible sprinkler drop. The Fire Protection Contractor shall be responsible for the installation of sprinkler head and the final connection, fill and test of the FlexHead ceiling system to sprinkler sub -main in accordance to NFPA, FM, UL, and state and local guidelines. FlexHead Ceiling Sprinkler System Model Numbers Model # 2024 Model # 2036 Model # 2048 Model # 2060 Model # 2072 2 ft. FlexHead sprinkler drop 3 ft. FlexHead sprinkler drop 4 ft. FlexHead sprinkler drop 5 ft. FlexHead sprinkler drop 6 ft. FlexHead sprinkler drop NOTE: FlexHead products are compatible with FM/UL and LPCB listed sprinkler heads. Usage of Flexible Piping Systems Contractor shall provide flexible piping connections to sprinkler heads for bath suspended and sheet - rock ceilings. All flexible piping systems shalt be UL Listed and FM Approved or LPCB certified and suitable for their intended use. All flexible piping connections to include a fully welded (non-mechanical fittings), braided, leak - tested sprinkler drop with a minimum internal corrugated hose diameter of 1 inch true -bore; and a one-piece ceiling bracket with removable attachment hub and self -securing integrated snap -on clip -ends, for attachment to ceiling grid without the need for a screw fastener. Acceptable Manufacturer(s): 1. FlexHead series 2000 as manufactured by FlexHead Industries of Holliston, MA USA (800) 829-6975 or (508) 893-9596, fax (508) 893-6020 in Lengths of 2 ft to 6 ft Testing and Approvals FM Global Testing — Approval Standard FM1637 FlexHeada series 2000 stainless steel sprinkler connections Hydrostatic Strength Test A sample FlexHead was subjected to a hydrostatic pressure of four (4) times the rated working pressure of 175 psi (1205 kpa) to 700, psi (4825: kpa) for a period of five minutes. The assembly showed no signs of rupture, cracking, permanent distortion, or deterioration of performance characteristics. The FlexHead successfully passed this test. Vibration Test A sample FlexHead was secured to a vibration table. The FlexHead hose was bent in a 90° angle and pressurized to 90 psi (620 kpa) and the mounting bracket and hose were then subjected to a total of 25 hours of severe vibration conditions. After the successful completion of the vibration tests the sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully passed this test. Friction Loss (Equivalent length of pipe) To determine the effect of the FlexHead to the discharge coefficient of the sprinkler, the average friction toss through the FlexHead shall be 1. equated to the theoretical length of nominal 1" diameter schedule 40 sprinkler pipe which would produce the same amount of friction toss. Please see friction loss table. Vacuum Test A sample FlexHead was subjected to a vacuum of 25 inHG for a period of five minutes. After the successful completion of the Vacuum Test the sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully passed this test. Pressure Cycling Test A sample FlexHead was filled with water and bent at a 90° angle and subjected to 20,000 cycles of pressure varying from 0 psi (0 kpa) to 175 psi (1205 kpa) at a rate of approximately 6 cycles per minute. After the successful completion of the pressure cycling tests the sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully passed this test. Fatigue Test A sample FlexHead was subjected to 50,000 cycles of repeated flexing at a rate of 5 to 30 cycles per minute per section 8.3 of ISO standard 10380. After the successful completion of the fatigue test the sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully passed this test. Head Deployment A sample FlexHead installed in a suspended ceiling was fitted with a sprinkler head and pressurized to 26-175 psi. The sprinkler head was then activated by a heat source at various pressures, and the sprinkler head deployed. The assembly showed no signs of distortion or deterioration of performance on the assembly or sprinkler head. The FlexHead successfully passed this test, APPROVED FLEXIBLE SPRINKLER HOSE WITH FITTINGS FOR COMMERCIAL SUSPENDED CEILINGS Flexible sprinkler hose with threaded end fittings are for use in commercial suspended ceilings. The flexible hoses are to be installed according to the manufacturer's directives. Unless indicated, the hoses have a rated working pressure of 175 (1205 kPa). Flexhead Industries, Inc. 56 Lowland St, Holliston MA 01746 Model NPT in. 2024H 1/2 2036H 1/2 2048H 1/2 2060H 1/2 2072H 1/2 Model NPT in. 2024/2024 75! 1/2 / 3/4 2036/2036 75: 1/2 / 3/4 2048/2048 75 1/2 / 3/4 2060/2060 75 1/2 /3/4 2072/2072 75: 1/2 / 3/4 Hose Assembly length ft (m) 2 (0.6) 3 (0.9) O9) 4 (1.2) 5 (1.5) 6 (1.8)...-_. -------- Hose Assembly length ft (m) 2 (0.6) 3 (0.9) 4 (1.2) 5 (1.5)... 6 (1.8) Model NPT in. Hose Assembly length ft (m) 2024E 1/2 (0.6) 2036E 1/2 3 (0.9) 2048E 1/2 4 (1.2) 1/2 6 (1.8) 2060E 2072E The "H" designation indicates a pressure rating of 300 psi (2070 kPa). Approval on the 2000H series flexible metal sprinkler hose is limited for use in commercial suspended ceilings, with a ceiling bracket system manufactured by FlexHead Industries Inc. The brackets are identified below. This is a standard flexible hose with a pressure rating of 175 psi (1205 kPa). Approval on these models of flexible metal sprinkler hose is limited for use in commercial suspended ceilings, with a ceiling bracket system manufactured by FlexHead Industries Inc. The brackets are identified below. This is a standard flexible hose with a pressure rating of 175 psi (1205 kPa). Approval on these models of flexible metal sprinkler hose incorporates a stainless steel elbow welded on the outlet end of hose and are limited for use in commercial suspended ceilings, with a ceiling bracket system manufactured by FlexHead Industries Inc. The brackets are identified below. The seven FlexHead Industries, Inc. Brackets are identified as follows: Part Number SP-24-BKT (1) SP = Single Port SP-24-BKT (2) MP-24-BKT MP = Multiport MP-24-BKT-2 SP-06-TZ-BKT TZ = Tech Zone AD-16-BKT-2 AD = Adjustable AD-24-BKT-2 BKT = Bracket (1) = 1 Piece (2) = 2 Piece 24 = Length in inches of bracket 06 = Length in inches of bracket 16 = Length in inches of bracket 24 = Length in inches of bracket Testing and listings Underwriters Laboratory Testing --• Listing Standard UL1474 FlexHeadr series 2000 stainless steel sprinkler connections Hydrostatic Pressure Test A sample FlexHead was subjected to a hydrostatic pressure of five (5) times the rated working pressure of 175 psi (1205 kpa) to 875 psi (6030 kpa) for a period of one minute. The assembly showed no signs of rupture, cracking, permanent distortion, or deterioration of performance characteristics. The FlexHead successfully passed this test. Vibration Test A sample FlexHead was subjected to hydrostatic pressure of 500 psi (3.45 MPa). The FlexHead hose was bent in a 90° angle and pressurized to 175 psi (1.21 MPa) and the mounting bracket and hose where then subjected to a total of 60 hours of F '' vertical vibration and 60 hours of horizontal . vibration with the amplitude of 0.04 inch (1.02 mm) at a continuously varying frequency between 18 and 37 hertz. After the successful completion of the vibration tests the sample was subjected to the hydrostatic pressure test at 500 psi and showed no signs of deterioration or leakage. The FlexHead successfully passed this test. Friction Loss (Equivalent length of pipe) To determine the effect of the FlexHead to the discharge coefficient of the sprinkler, the average friction loss through the FlexHead connector shall be equated to the theoretical length of nominal 1 inch diameter schedule 40 sprinkler pipe which would produce the same amount of friction loss. Please see friction loss table. Mechanical Strength Test A sample FlexHead was secured and subjected to a torsion force with a torque of 60 pound -feet (81 Nm) applied to the outlet. After the successful completion of the mechanical strength test the sample was subjected to the hydrostatic pressure test at 175 psi (1205 kpa) and showed no signs of deterioration or leakage. The FlexHead successfully passed this test. High Temperature Exposure Test A sample FlexHead was subjected to hydrostatic pressure of 500 psi (3.45 MPa) and then subjected to a temperature of 375° F (191° C) for a period of 90 days. After the successful completion of the high temperature test the sample was subjected to the hydrostatic test of 500 psi (3.45 MPa) for a period of one minute and showed no signs of deterioration or Leakage. The FlexHead connector successfully passed this test. Salt Spray Corrosion Test A sample FlexHead was subjected to salt spray (fog) connector test, per ASTM B117-94, for a period of 10 days and showed no signs of deterioration or incipient corrosion. The FlexHead successfully passed this test. Water Hammer Test A sample FlexHead was subjected to 3,000 applications of pressure pressure surges from 50-500 psig at a rate of 60 cycles per minute and showed no signs of deterioration or leakage. After the successful completion of the water hammer test the FlexHead was subjected to the hydrostatic test of 500 psi (3.45 MPa) for a, period of one minute and showed no signs of deterioration or Leakage. The FlexHead successfully passed this test. Freezing Test A sample FlexHead was filled with water and exposed to an atmosphere of 10 F (-29 C) for a period of 24 hours and showed no signs of deterioration or Leakage. After the successful completion of the freezing test the FlexHead was subjected to the hydrostatic test of 500 psi (3.45 MPa) for a period of one minute and showed no signs of deterioration or leakage. The FlexHead successfully passed this test. C LISTED US VENF.EX5269 Flexible Sprinkler Hose Fittings Certified for USA and Canada FLEXHEAD INDUSTRIES LOWLAND IND PARK 56 LOWLAND ST HOLLISTON, MA 01746 USA EX5269 Models 2024H, 2036H, 2048H, 2060H, 2072H, flexible sprinkler hose fittings having a 300 psi rated pressure. For use with ordinary, intermediate and high temperature rated automatic sprinklers. Models 2024S, 2036S, 2048S, 20605, 20725 flexible sprinkler hose fittings having a 175 psi rated pressure. Fore use with ordinary, intermediate and high temperature rated automatic sprinklers. Models 2024 24 OAL, 2036 36 OAL, 2048 48 OAL, 2060 60 OAL, 2072 72 OAL, flexible sprinkler hose fittings having a 175 psi rated pressure. Fore use with ordinary intermediate and high temperature rated automatic sprinklers. Modes 20241, 2036I, 2048I, 2060I, 20721 flexible sprinkler hose fittings having a 175 psi rated pressure. Fore use with ordinary, intermediate and high temperature rated automatic: sprinklers. Maximum number of bends, maximum bend angles and associated pressure loses are shown in the manufacturer's installation instructions. Testing and Certifications Loss Prevention Certification Board — Loss Prevention Standard LPS 1261 FlexHead" series 2000 stainless steel sprinkler connections Hydrostatic Pressure Flexible hose will be subjected to 4 times the maximum working pressure for a period of one hour. FlexHead successfully passed this test. Elevated Temperature Test Flexible hose will be subjected to elevated temperature of 122F (50C) for 90 days, then subjected to 4 times the maximum working pressure. FlexHead successfully passed this test. Sulphuric Acid Test Flexible hose will be subjected to 4 times the maximum working pressure after conditioning in sulphuric acid. FlexHead successfully passed this test. Crushing Load Test The flexible connection with the cover removed shall be subjected to a crushing load of 100kg applied evenly over a length of 50mm for 30s. The connection shall not collapse or show signs of permanent deformation in excess of 5% of any appropriate dimension measured before the test. FlexHead successfully passed this test. Salt Spray Test Flexible hose will be subjected to salt spray conditioning in accordance to BSEN 60068-2- 53:1996 Test K6 Salt Mist Cyclic (Severity 1). Then it will be subjected to hydrostatic test 4 times maximum working pressure. FlexHead successfully passed this test. S02 Conditioning Test Flexible hose will be subjected to 4 times the maximum working pressure after completion of the S02 conditioning. FlexHead successfully passed this test. Dry Pipe Fire Test A flexible assembly shall be pressured with air to 3 bar for 3 minutes. The flexible hose assembly shall then be subjected to a fire test. The air pressure shall be kept constant by venting. The flexible hose must maintain integrity of the pipework throughout the test. FlexHead successfully passed this test. Sprinkler head Activation Test Flexible hose and bracketing system will be installed to installation instructions into a 600mm x 600mm ceiling tile. Sprinkler head will be activated at 12 bar (175 PSI) and maintain running pressure at 11 bar (160 PSI) for 2 minutes. The sprinkler head must remain in position. FlexHead successfully passed this test. Pressure Loss Test To determine the effect of the flexible hose to the discharge coefficient of the sprinkler, the average friction toss through theflexible hose shall be equated to the theoretical length of nominal 1" diameter schedule 40 sprinkler pipe which would produce same amount of friction toss. Please see friction loss table. Loss Prey nlion ica ion Board 14/41 V.F 1 171 LPCB' APPENDIXTalTri.6.'cATE,N(1:76.4a-. FLEXHEkD INDUSTRIES INC 56 LoWlanasSife0t,'HolliOtbkh*G1:746, USA Model Length (mm)SlPPIY Nominal Size / Connection . Max: Working. ' PressuroAlArl- LPCB Ref, No. I Oiitjet • 2024 : , ..„ . ' , R1 (1" NP.T) or (I" , BSPT) 7 External thread . . .. "•:' : HOW Or RcY. (K" Or ::: V:NPT) or (14" or %" BSP internal thread . .. „ ... ,. , , _ .., ' ":-.12"'.',.-: '. • . .764a/01 ' • 2036. : .. ' . :40t)', :., ,/,, ' • ''" '''' ''. ' ' 2048 1200 . '. :::120.p..:::;::,,:„ 2060 1500 `..! 2072 : ,,: 1806 • '-': , .. • -7' 202:4H - --:'-----90 RI (1" NPT) or'.•Re1/2orieRc% (1" BSPT) External thread ... (% or ii" NAT) or CA'. or V." BSP, '." • Internal thread • , - • • • . . ...2 - 26i, : ' .,. •;.„.".!, 764a/02. 1.]361-r.'..,, . 900. " 2648H -.' -! .. : ,.iiio; . / . .,- . • ' :206611. -, _ . 1506 .2072H; ..,:..f - 1800 This certificate ia.validiuntilwithdrawn by.LPCB. Tacheck,the validity andlhe authenticity of this 'certificate. please visit our website wwW.FiedBookLive.com or contect410. Signed on behalf of thes-LPGB Nattle: Simian Bird Date ,of 1sue::21,Juhp:2008 .n. LPCB Is part of BHE CertiticattofELtd., Garston, Watford1/025•5X,X. Tel -1,44 (0)18.23 664100 FaX.4.44 (0923864803 www.HedBOOklive.Orn This certificate remains the property of BRE Certification lid'*04.1-Satied subject to terms and •conditions and is Maintained and held In force through 'regUlar,'"Sur,Veiliance activities. 13F667•RpArWon 0, 03 January 2006 3- , "'• Valid for 3 Yeato Maiimuni — laigree;(4014._r•-;_, ri Gierigeeten SEISMIC At,}V1ORAGE PRE- - "0 ;# DETAIL CEILING 140V/4r Office-of:Statewide Health Planning and Development ANCHORAGE PREAPPROVAL C.6. WT. •b.q LBS. MAX. EXISTING HATER SUPPLY LINE • PER'NFPA 6UIDE LINES 1516INEER OF RECORD) FLEXHEAD13RACKET 5NAPS-ONTO T,BARLEILING 16 GA. GALVANIZED SHEET METAL 20 6A. GALVANIZED SHEET METAL T-43AR CEILIN6 6R10 EN6INLTR OF RECORD) fLEVAT1 OJ SPRINKLER HEAD Or OTHERS) GENERAL.NOTE-5: 1, FORCES, ARE DETERMINED. PER 2001 CG SECTION 1662A; Co # ,0041p = 1.0, 1p=, 15, R HORIZONTAL FORCE NH) 0.q4n VERTICAL FoRat (vv) = 033(%4) 2 ENGINEEit OF ECORD FOR THE eUILOING SHALL PROVIDE SUPPORT STRUCTURE DESI6NED TO SUPPORT lAtEiors AND FORCES SHOVIN. APPROVED Fixed EquipmentAnchorage 00r:a Stateyilde Health pirinhIntfirod peVeltyment OPA- 0672 August 10, 2604. r 'iv ANCHORAGE tit =WC ENGDWERWG www.equipoontanchoramoon FLEXHEAD INDUSTRIES Dm it IA BRIE JOS Pei 114441 FLEXHEAD SPRINKLER CONNECTIONS MODEL I 2024, 203a 2i ' : 2060, 2072 nAM 84/1"4 SEISMIC At,}V1ORAGE PRE- - "0 ;# DETAIL CEILING 140V/4r Office-of:Statewide Health Planning and Development ANCHORAGE PREAPPROVAL C.6. WT. •b.q LBS. MAX. EXISTING HATER SUPPLY LINE • PER'NFPA 6UIDE LINES 1516INEER OF RECORD) FLEXHEAD13RACKET 5NAPS-ONTO T,BARLEILING 16 GA. GALVANIZED SHEET METAL 20 6A. GALVANIZED SHEET METAL T-43AR CEILIN6 6R10 EN6INLTR OF RECORD) fLEVAT1 OJ SPRINKLER HEAD Or OTHERS) GENERAL.NOTE-5: 1, FORCES, ARE DETERMINED. PER 2001 CG SECTION 1662A; Co # ,0041p = 1.0, 1p=, 15, R HORIZONTAL FORCE NH) 0.q4n VERTICAL FoRat (vv) = 033(%4) 2 ENGINEEit OF ECORD FOR THE eUILOING SHALL PROVIDE SUPPORT STRUCTURE DESI6NED TO SUPPORT lAtEiors AND FORCES SHOVIN. APPROVED Fixed EquipmentAnchorage 00r:a Stateyilde Health pirinhIntfirod peVeltyment OPA- 0672 August 10, 2604. PRE -APPROVAL OF ANCHORAGE FOR FIXED HOSPITAL EQIJIPMENT Application No.. OPA-0672 FM APPROVAL AND UL FIRE SPRINKLER CONNECTIONS has been,exatnined for conformance to thecurrent requirements adopted by the Office of Statewide Health Planning and Development, Facilities Development Division. Signed this ThursdaY, August 12, 2004. STATE OF -CALIFORNIA, HEALTH AND HUMAN $ERV10ES AGENCY OFFICE OF STATEWIDE HEALTH PLANNINGAND DEVELOPMENT !FACILITIES DEVELOPMENT DIVISION. Program AdatinAtor Thisapproval must be renewed every three (3) years, Other conditions requiring renewal are listedlbelow: I. Changes in the applicable codes and regulations, 2. Changes in the manufactured product (fixed equipment), 3. Changes in the methods Of anchorage or anchorage devices:, List of Approved Documents: • Sheet Nos. Sheet 1 of 2 through:Shoo/of-2: C LISTED US Underwriters Laboratories Inc: June 21, 2001 FlexHead Industries Mr. Norm MacDonald 56 Lowland St. Holliston, MA 01746 :4iS r'a�r 1�1 fowls Minitttonw: i s Ilan! %alimkuatro Cfal• 1 n htrAymoialin Our Reference: File EX5269 Subject: FlexHead Flexible Sprinkler Hose Fittings Installed Onto Dry Wall Ceiling Grid Dear Mr. MacDonald: This letter is in regard to the subject. Base upon review of the FlexHead UL Listed flexible sprinkler hose fitting system, installation onto a dry wall ceiling grid is acceptable when the ceiling -mounted bracket is screwed to a rigid surface. Self -tapping screws are used to affix the FlexHead mounting bracket to the surface, using the four ports provided which are pre- drilled onto the mounting bracket. Very truly yours, EMIL W. MISICHKO (Ext. 42036) Engineering Group Leader Conformity Assessment Services Department 3011CNBK Emil W. Misichko@us.ul.com A not-for-profit organization dedicated to public safety and committed to quality service Flexhead Industries ., 56 Lowland,Streets Holliston, MA 01746 Attn: Norm MacDonald Subject: IBC/ASCE 7 Compliance Dear Mr. MacDonald, E ©C1P?1IEN'T A NCHORAGE & :SEISMIC 1ENGI EERING SSB, Huiattngton Drive. Suite P2,77 ri:cadia. CA ii sZ: (f26)445-0620 626) 7•S; ; s6 May 18, 2004 I have reviewed the material that was sent to me regarding the flexible sprinkler drops, your company manufactures. As you are aware, our firm focuses its efforts solely on seismic restraint of equipment and ceiling systems. We are quite impressed with the freedom of movement that your solution provides. Regarding ASCE 7; in section 9.6.2.6.2.2 the acceptance criteria states that all sprinkler heads must have a horizontal freedom of movement of at least one inch in every direction. Your flexible sprinkler drops not only provide far more than the specified one inch, but they also allow vertical motion and rotation as well. It is quite apparent that the use of this product would not only conform to the requirements of ASCE 7 but exceed them as well. The FlexHead product is satisfactory and complies with the intent of the provisions of code section 1621 of the IBC and ASCE 7 subsections 9.6.2.6.2 and 9.6.2.6.2.2 with reference to sprinkler heads having a minimum clearance on all sides; and the product, for the purpose intended, meets or exceeds these provisions of these in quality, strength, effectiveness, fire resistance, durability and safety. Yours Very truly, Richard 13. La 13ne Y.E., Principal EASE Incorporated Accepted For Use City of New York Department Of Buildings MEA /—qq,-- 6 Vo Bti-ILDINGS z NYC Departmant of Buildings 260. Broadway, New York..NY 10007 ilitricia J. Lancaster, FAIA, Commissiener dusieg"6-c- 56? LMjjg4 *td Ws A. Dear Applicant: Date! ponOct, Gottfried, P.E. Direcloi;.NiBA Division 212,56,342 212.5660,40fax donaldgpolldings.nyo,gov 10 2-064. Enclos "is a final official.signed copy of MEA acceptance of your product(s), MEA 2L9 1 11 — which you may use as proof of your product(s) acceptance in New Yoric titY. Vol 2. This document together with proper labeling and inst4Ilation in accordance with New York City Building Codewill enable theinspector to know that the,product(s),installed is (are) All shipments and deliveries. of accepted materialto the job -site are required to be labeled or tagged in accordancewith the format below: CompanyName Donald Gottfried, P.E. Director Materials and Equipment Acceptance Division NYC.goVibuilgings FlexHead Industries was founded in 1992 to help engineers, builders and owners increase the safety of their buildings. Our patented sprinkler connection technologies show that it's possible to comply with codes cost-effectively. We're proud to help reduce the risks of property damage and loss of life in a wide variety of buildings, domestically and world-wide. FlexHead manufactures sprinkler connections for all types of applications including: Commercial • Government • Offices Restaurants • Retail • Schools Cleanrooms Biotechnology Electronics High-end commercia ceilings ars Pharmaceuticals • Semiconductors Exhaust ducts` « Aerospace Automotive 0. Biotechnology Electronic Forest, Paper. pu R. l • Laboratories Petrochemical [ 6 Pharmaceuticals 0 : Restaurants ® Semiconductors • Steel manufacturers Institutions Concrete penetrations:: for sidewall and pendant applications Correctional centers i.. Mental health facilities Seismically qualified. FlexHead connections allow for independent movement between sub -mains and •ceilings. They're the only flexible sprinkler connection to be qualified for use in Seismic Design Categories D E and F. FlexHead Industries, Inc. warrants that its products will ; be free from defects in materials and workmanship under normal conditions of use and service for a period of one year from date of sale. Our obligation under this warranty is limited to repairing or replacing any product that is returned to us with transportation charges prepaid within one year after the date of original sale and that our examination shows to our satisfaction to have been defective in materials or workmanship under normal conditions of use and service. The decision as to whether to repair or to replace any product shall be made by us, and any repair shall be made at our facility. Notwithstanding the foregoing, the following arc,. 1_: specifically excluded from the coverage of this warranty: (a) the sprinkler head of any FlexHead Industries, Inc. product, but FlexHead Industries, Inc. hereby assigns to the original purchaser of any such product the right to enforce the warranty, if any, issued by the manufacturer of such sprinkler head; (b) defects resulting from ordinary wear and tear, including, without !imitation, the replacement of the so called poly bag components of any FlexHead Industries, Inc. product; (c) products that have been altered in any manner by the buyer or by anyone other than FlexHead Industries, Inc.; (d) products that have been subjected to misuse, abusive use, or damage by accident or casualty; (e) products that have been installed or used in a manner contrary to our specifications, instructions or recommendations, (f) products that have been installed or used in a manner that is not in compliance with alt applicable requirements of any code, law, regulation or rule of any federal, state or local governmental or industry authority; and (g) products that have not been inspected and maintained in accordance with our specifications, instructions or recommendations, including, without limitation, our recommendations as to following the inspection and maintenance standards published by Factory Mutual Research Corporation (FMRC) and the National Fire Protection Association (NFPA); and (h) products that have been affected by Microbiologically Influenced Corrosion (MIC). This warranty is not assignable and shall benefit only the original purchaser of a FlexHead Industries, Inc. product. If any provision hereof or any portion of any provision shall be held invalid, the remainder of this Limited Warranty shall not be affected thereby, and all provisions of this Limited Warranty shall remain valid and in full force and effect to the fullest extent permitted by law. THIS WARRANTY IS IN LIEU OF ALL IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY AND WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. NOTWITHSTANDING ANY PROVISION TO THE CONTRARY HEREIN OR ANY APPLICABLE LAW TO THE CONTRARY, IN NO EVENT SHALL FLEXHEAD INDUSTRIES, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES UNDER ANY CIRCUMSTANCES WHATSOEVER, WHETHER ARISING FROM ANY BREACH OF THIS LIMITED WARRANTY OR OTHERWISE ARISING FROM OR IN CONNECTION WITH THE USE OR OPERATION OF, OR ANY DEFECT IN, ANY FLEXHEAD INDUSTRIES, INC. PRODUCT, OR OTHERWISE. The risk of damages from any breach of warranty with respect to injury to any person will be born by the purchaser of FlexHead Industries, Inc. product. SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East • Tacoma, Washington 98424 (253) 926-1880 • FAX (253) 926-2350 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME SC -5 RETAIL LA Z BOY T.I. JOB NO. TC7029 DATE 11/12/07 ADDRESS 17305 SOUTHCENTER PARKWAY BY NICK GRASSI TUKWILA, WA SYSTEM DESIGNATION: WET HAZARD DESCRIPTION: MERCANTILE HAZARD CLASS PER NFPA 13 : ORDINARY GP. II SPECIFIC RULING: RULING MADE BY: DENSITY: .20 OF GPM OVER THE MOST HYDRAULICALLY REMOTE 1500 SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: INSIDE HOSE 0 GPM OUTSIDE HOSE IN -RACK SPRINKLER DEMAND SYSTEM TYPE: WET "C" FACTOR OVERHEAD : 120 250 GPM 0 GPM ADDED AT: NODE 2 TOTAL NUMBER OF SPRINKLERS THIS SYSTEM MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: SPRINKLER MANUFACTURER: VIKING "C" FACTOR UNDERGROUND : 140 VARIES SQUARE FEET MODEL: VK532 TEMPERATURE: 155 ° F K -FACTOR: 11.2 ORIFICE SIZE: 11.2K 142 WATER SUPPLY: STATIC 140 PSI RESIDUAL 20 PSI FLOW 5876 GPM ELEVATION OF TEST: SAME AS SITE 2005 DATA PROVIDED By: CITY OF TUKWILA LOCATION OF TEST: WATER MODEL DATE OF TEST: BASE OF RISER DEMAND 545.17 GPM REQUIRED AT 121.60 PSI (INCLUDING 0 GPM FOR HOSE STREAMS) SUMMARY 795.17 GPM REQUIRED AT 127.78 PSI AT CONNECTION TO PUBLIC MAIN (INCLUDING 250 GPM FOR TOTAL HOSE STREAMS) SUBMITTAL SERIAL NO:2244HY1 SC -5 RETAIL LA Z BOY T.I. RETAIL ORDINARY HAZARD GP. II DENSITY: HEAD LISTING/1500 SQ FT FILENAME: 7029104 FLOW TEST RESULTS Water Supply STATIC 140.00 PSI RESIDUAL 20.00 PSI @ 5876.00 GPM CITY PRESSURE AVAILABLE AT 795.2 GPM 137.03 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 101 102 103 104 105 106 107 108 73.37 74.09 65.76 65.31 65.00 67.63 67.17 66.85 65.00 65.00 65.00 65.00 65.00 65.00 65.00 65.00 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 2 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 92 TO 102 42.92 43.76 34.48 34.00 33.68 36.46 35.96 35.62 545.17 GPM 250.00 GPM 795.17 GPM 127.77 PSI 0.00 PSI 27.50 FPS 11-12-2007 PAGE 1 SUBMITTAL SERIAL NO:2244HY1 SC -5 RETAIL LA Z BOY T.I. RETAIL ORDINARY HAZARD GP. II DENSITY: HEAD LISTING/1500 SQ FT FILENAME: 7029104 11-12-2007 PAGE 2 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 95 105 94 95 Q 65.00 Q 65.00 98 108 97 98 Q 66.85 Q 66.85 1.049 L 15.60 C=120 PT 33.68 (105) F=T,E F 7.00 PE -3.68 DR T 22.60 1.1518 PF 26.03 2.185 L 17.00 C=120 PT 56.03 ( 95) F=0 F 0.00 PE 0.00 BN T 17.00 0.0323 PF 0.55 PT 56.58 ( 94) 1.049 L 16.60 C=120 PT 35.62 (108) F=2E/E F 6.00 PE -3.90 DR T 22.60 1.2131 PF 27.42 2.185 L 17.00 C=120 PT 59.14 ( 98) F=0 F 0.00 PE 0.00 BN T 17.00 0.0340 PF 0.58 PT 59.72 ( 97) 97 107 1.049 L 16.60 C=120 PT 35.96 (107) Q 67.17 F=2E/E F 6.00 PE -3.90 DR T 22.60 1.2238 PF 27.66 96 97DQ 66.85 2.185 L 17.00 C=120 PT 59.72 ( 97) Q 134.01 F=0 F 0.00 PE 0.00 BN T 17.00 0.1232 PF 2.09 PT 61.81 ( 96) 96 106 1.049 L 17.60 C=120 PT 36.46 (106) Q 67.63 F=2E/E F 6.00 PE -3.90 DR T 23.60 1.2395 PF 29.25 12 96DQ 134.01 2.185 L 73.42 C=120 PT 61.81 ( 96) Q 201.64 F=T F 14.00 PE 0.00 BN T 87.42 0.2624 PF 22.94 PT 84.75 ( 12) 94 104 1.049 L 15.60 C=120 PT 34.00 (104) Q 65.31 F=T,E F 7.00 PE -3.68 DR T 22.60 1.1619 PF 26.26 93 94DQ 65.00 2.185 L 17.00 C=120 PT 56.58 ( 94) Q 130.31 F=0 F 0.00 PE 0.00 BN T 17.00 0.1170 PF 1.99 PT 58.57 ( 93) SUBMITTAL SERIAL NO:2244HY1 SC -5 RETAIL LA Z BOY T.I. RETAIL ORDINARY HAZARD GP. II DENSITY: HEAD LISTING/1500 SQ FT FILENAME: 7029104 11-12-2007 PAGE 3 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 93 103 1.049 L 16.60 0=120 PT 34.48 (103) Q 65.76 F=T,E F 7.00 PE -3.68 DR T 23.60 1.1769 PF 27.77 11 93DQ 130.31 2.185 L 77.42 0=120 PT 58.57 ( 93) Q 196.07 F=T/2E F 28.00 PE 0.00 BN T 105.42 0.2492 PF 26.27 PT 84.84 ( 11) 92 102 1.049 L 16.10 0=120 PT 43.76 (102) Q 74.09 F=2E/E F 6.00 PE -3.68 DR T 22.10 1.4672 PF 32.43 91 92 4.298 L 17.00 0=120 PT 72.51 ( 92) Q 74.09 F=0 F 0.00 PE 0.00 BN T 17.00 0.0015 PF 0.03 PT 72.54 ( 91) 91 101 1.049 L 17.10 0=120 PT 42.92 (101) Q 73.37 F=2E/E F 6.00 PE -3.68 DR T 23.10 1.4411 PF 33.29 10 91DQ 74.09 2.185 L 73.42 C=120 PT 72.53 ( 91) Q 147.46 F=T F 14.00 PE 0.00 BN T 87.42 0.1471 PF 12.86 PT 85.39 ( 10) 11 12 4.298 L 8.00 0=120 PT 84.76 ( 12) Q 201.64 F=0 F 0.00 PE 0.00 FM T 8.00 0.0097 PF 0.08 10 11DQ 196.07 4.298 L 16.00 0=120 PT 84.84 ( 11) Q 397.72 F=0 F 0.00 PE 0.00 FM T 16.00 0.0342 PF 0.55 7 10DQ 147.46 4.298 L 200.00 0=120 PT 85.39 ( 10) Q 545.17 F=4E F 60.00 PE 1.73 FM T 260.00 0.0613 PF 15.94 6 7 4.298 L 11.67 0=120 PT 103.06 ( 7) Q 545.17 F=0 F 0.00 PE 5.06 FR T 11.67 0.0613 PF 0.72 SUBMITTAL SERIAL NO:2244HY1 SC -5 RETAIL LA Z BOY T.I. RETAIL ORDINARY HAZARD GP. II DENSITY: HEAD LISTING/1500 SQ FT FILENAME: 7029104 11-12-2007 PAGE 4 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 5 6 4.298 L 11.00 C=120 PT 108.84 ( 6) Q 545.17 F=4E,GV F 63.00 PE 0.00 FR T 74.00 0.0613 PF 4.54 4 5 Q 545.17 4.000 L 3.50 C=120 PT 113.38 ( 5) F=DIJ1 F' 0.00 PE 1.52 MA T 3.50 0.0869 PF 0.30 4" 350 ADABGVIC DOUBLE CHECK ASSEMBLY 6.40 2 4 4.095 Q 545.17 UN L 13.00 C=140 PT 121.60 ( 4) F=2E F 18.00 PE 2.17 T 31.00 0.0583 PF 1.81 0 2DQ 250.00 8.265 L 445.00 C=140 PT 125.58 ( 2) Q 795.17 F=2T,GV/GV,E F 135.00 PE 0.00 UN T 580.00 0.0038 PF 2.20 PT 127.78 ( 0) 1 -6° 4,-2" 7,- 0 45-0" - 34-0" r 31'-7.5" - t 25-9.25" 5-2.75" 0 0 11'-0 0 0 45-0" 42-0" 11'-0° 4 5-1 ro m VAS N.A.S. N.A.S. N.A.S. SPRINKLERS ARE PERMITTED TO BE OMI I I ED WHERE THE CANOPY OR ROOF IS OF NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE CONSTRUCTION.PER NFPA #13 (2002 ED.) SECTION 8.14.7.2 EXCEPTION 1. 4-10 r 0 SPRINKLER PLAN 8 16 SCALE 1/8"=l'-0° N.A.S. FITTER/LISTER NOTES 1. ROTATE SPRINKLER PIPE 180° AT COUPLINGS ON LINES 8,9, AND12. 2. HEADS TO BE CENTER OF TILE IN 2x2 SQUARE. HYDRAULICALLY MOST DEMANDING AREA: SYS# 1 DENSITY: LISTING GPM OVER 1500 SQUARE FEET SYSTEM DEMAND AT BOR: 545.17 GPM AT 121.60 PSI ( INCLUDING 0 GPM FOR INSIDE HOSE STREAMS ) O SCOPE OF WORK SMITH FIRE SYTEMS (SFS) WILL MODIFY THE EXISTING WET PIPE FIRE SYSTEM TO ACCOMODATE THE NEW TENANT IMPOVEMENT SPACE. SFS WILL BEGIN WORK INSIDE THE BUIDLING AT THE EXISTING SPRINKLER BF.ANCHLINES ALL WORK WILL BE PER NFPA #13 (2007) AND THE CITY OF TUKWILA. - DESIGN CRITERIA MERCANTILE : ORDINARY HAZARD GP.2 DESIGN DENSITY: 0.20 GPM/SQ. FT. OVER 1500 SQ. FT. PER NFPA 13 - 2007 EDITION AND THE CITY OF TUKWILA EXISTING BRANCHLINE DETAIL A EXISTING BRANCHLIKE 1" ELBOW DETAIL C 1" ELBOW 1(0-3) NIPPL- EXISTING BRANCHLINE 36" FLEX DROP DETAIL B 1" ELBOW - 1(0 -3) NIPPLE EXISTING BRANCHLINE ;DETAIL D ACCEPTED I Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city ndards- Ac-ceptance is-ubject to errors and omissions Eahich do not authorize violations of adopted : tamer us r;.._ - -lmsnces. The responsibility for the adeo.uo razi.t totally with the designer.. Additions. •�,-'<��-c�:;.<_ ine revisions to these drawings atter is data •rls oiaceorance rind will require a ubmittal cr revised drawings for subsequent approval. Final acceptzrc_= is subject to field test and inspection by The Tukwila Fh-e i=t elention Bureau. Date: 11/-3O o`) B/: -Col-rl� wifL w -$.R. 0. cw.,/'°s hr. - Cot--pl,( w:iL NFPM 13 oSr},r,,}.,, -}yS4t TUKWILA FIRE DEPARTMENT Please call: 575.4407, ---- and give this job No. 07 -S- - - -. and exact address for shuti gown or restoration aporovaV FELE l a of increased demand our inspectors' s,-ne ui. are booke.d 3-7 days ahead. Therefo-e, you wiIi need to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an in7A_G',lon. PAID NOV 27 2001 Tukwila Fire -# HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND REVISIONS SYM MANUFACTURER VIKING S.I.N. VK534 TYPE EC/SSP MODEL VK534 SPRINKLER FINISH CHROME CHROME 11.2K THREAD SIM 3/4" TZZ 155° 18 TOTAL THIS SHE 18 AFF BOB BOD B0J BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURUN BOTTOM OF TRUSS CUT TO Sur' FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE BOD CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO DATE BY REASON FOR REVISION CONTRACT WITH DECKER DEVELOPMENT & CONST. 117 EAST LOUISA ST. #230 SEATTLE, WA 98102 PROJECT MANAGER : BRAD DECKER PHONE : 206.545.4964 FAX : 206.545.4952 SUPERINTENDENT : MIKE SHEPARD PHONE : 206.228.7316 FAX: OUgh Da 7 CERTIFICATE OF COMPETENCY STAMP RISER ROOM AREA OF WORK KEY PLAN SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST agirs.' TACOMA, WA 98424 CONTR. REG. NO. SMITHFS1360T Bus: ( 253) 926 -1880 FAX: ( 253) 926 - 2350 SC -5 RETAIL LA Z BOY 17305 SOUTHCENTER PARKWAY TUKWILA, WA DESIGNER NICK G DATE SHEET JOB NO. 10.12.07 1 OF 1 TC7029