Loading...
HomeMy WebLinkAboutPP - 10655 TUKWILA INTERNATIONAL BLVD - ROTO ROOTER - PERMITS AND PLANS10655 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS 13-F-060 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 0423049169 Site Address: 10655 Tukwila International Blvd Suite Number: Floor: Tenant Name: Roto Rooter New Tenant? ❑ - Yes [✓] 'No Property Owner's Name: Desimone Trust / BNY Mellon Mailing Address: 1201 3rd Ave, ste 5010 Seattle 98101 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Kristopher Conner Day Telephone: 253-753-6660 CompanyName: Froula Alarm Systems, Inc. Mailing Address: 861 Industry Drive Tukwila WA 98188 E-mail Address: kris@froulasolutions.com City State Zip Fax Number: 206-575-8168 Total number of new/relocated devices or sprinkler heads: 40 Valuation of Project (contractor's bid price): $ 6 , 500 Scope of Work (please provide detailed information): Install voluntary fire alarm system. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNERNEOR AUTHORIZED AGENT: Signature: /•c// Print Name: Kristopher Conner Plan Permit App.doc Date: 3/1/13 Day Telephone: 253-753-6660 1/2/13 TFD FP Form 8 Farenhyt SILENT KNIGHT by Honeywell Intelligent Fire Alarm Control Panel Intelligent Fire Alarm Control Panel IFP -50 IFP -50 is an intelligent analog/addressable fire control panel (FACP). IFP -50 has a single line circuit (SLC) loop for connecting addressable detectors and modules and has two notification appliance circuits that can be programmed for notification outputs or auxiliary power. IFP -50 also has a built-in dual line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features such as detector sensitivity, day/night thresholds, drift compensation and pre -trouble maintenance alert. IFP -50 supports a variety of other devices that can be added to the system such as RA -100 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module, and Hochiki or Intelligent Device Protocol (IDP) devices. Features • Built-in support for up to 50 Hochiki devices or 50 IDP detectors and 50 IDP modules • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator for remote reporting of system activity and system programming • Central station reporting by point or by zone • Jumpstart® auto -programming • Supports Class B (Style 4) and Class A (Style 6 or Style 7) configuration for SLC • Distributed, intelligent power • Built-in synchronization for appliances from AMSECO, Gentex®, Faraday, System Sensor®, and Wheelock® • Sensor sensitivity settings and day/night sensitivity setting and automatic drift compensation • Notification circuits can be configured as 1 Class A (Style Z), 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power • Built-in annunciator with a backlit 80 -character LCD display • RS -485 bus provides communication to system accessories • Built-in RS -232 interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 24 VDC • Two built-in Form C programmable relays rated at 2.5 amps at 24 VDC • SLC device locator can be used to locate a single or multiple devices on a SLC loop • System automatically performs detector sensitivity test • 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable patterns • Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5650/5651 Silent Knight Software Suite (SKSS) • Improvements in SKSS deliver five times faster upload/downloads • Non volatile event history stores up to 1000 events • 125 software zones and 125 output groups Agency Listings MEA 429-92-E Vol. XVI 1 IFP -50 1`y SRE.T... 1[*�` KSIGHT co IFP -50 • 2.5 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 7 amp hours). • Programmable date setting for Daylight Saving Time Installation The IFP -50 is a surface mount FACP. Compatibility The IFP -50 SLC supports multiple device types of the same protocol: • Hochiki • IDP You cannot mix Hochiki and IDP devices on a FACP. However, any combination of addressable devices of the same protocol can be used on the IFP -50. Specifications Physical Dimensions: 12.75"W x 15.2"H x 3.4"D (36.8 W x 62.9 H x 9.8 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red P/N 350328 Rev F © 2010 Honeywell International Inc. Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing Electrical Primary AC: 120 VRMS @ 50/60 Hz, 2.7A Total Accessory Load: 2.5A @ 27.4 VDC power -limited Standby Current: 200 mA Alarm Current: 325 mA Battery Charging Capacity: 7 to 35 AH Battery Size: 7 AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Notification Appliance Circuits Two circuits that can be programmed individually as: Notification Circuits: 2.5A per circuit @ 27.4 VDC, power -limited Auxiliary Power Circuits: 2.5A per circuit @ 27.4 VDC, power -limited Indicator Lights Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced Trouble (Yellow): Flashes when a trouble condition exists; solid when trouble silenced Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared Power (Green): Flashes for AC failure; solid when power systems are normal Telephone Requirements: FCC Part 15 & Part 68 approved Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signalling services. Other Approvals: UL Listing; CSFM 170-0559: 144; MEA 429-92-E Vol XVI Approved Releasing Solenoid Manufacturer Part Number Rating Asco T8210A107 24 VDC, 2.5A Asco 8210G207 24 VDC, 2.5A SILENT KNIGHT by Honeywell Ordering Information IFP -50 Intelligent Fire Alarm Control Panel. SBUS Accessories RA -100 RA -1000 RA -1000R 5496 5824 5880 5865-3 & 5865-4 5883 Remote Annunciator. Similar in operation and appearance to FACP annunciator. Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. Intelligent Power Module. 6 amp power module that provides four additional power limited notification appliance circuits. Serial/Parallel Printer Interface Module. Provides one parallel and one RS -232 serial port for connecting a printer to IFP -50. LED I/O Module. Provides 40 LED outputs, eight normally open dry contacts inputs and one piezo output. LED Fire Annunciators. Provides 30 programmable LED outputs and a piezo sounder. Relay Interface Board. Provides 10 general purpose Form C relays. Used with 5880. Hochiki and IDP Devices See the specification sheets listed below for a complete listing of the Hochiki and IDP devices. 350360 Hochiki Devices (SD) data sheet 350361 Intelligent Device Protocol (IDP) Devices data sheet Miscellaneous Accessories 5650/5651 Silent Knight Software Suite. Provides programming, upload/download, and event reporting. Order 5650 for PC parallel port compatibility or 5651 for PC USB port compatibility. 5670 Silent Knight Software Suite. Provides facility monitoring. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472- 1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com Made in the U.S.A. Farenhyt SILENT KNIGHT by Honeywell Intelligent Devices Intelligent Thermal and Rate -of -Rise Thermal Detectors IDP -Heat, IDP -Heat -HT, & IDP-Heat-ROR The IDP -Heat, IDP -Heat -HT, and IDP-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight IFP -series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP -Heat is a fixed temperature thermal detector that uses a thermistor sensing circuit to produce 135°F (57°C) fixed thermal detection. IDP -Heat -HT is a variable high temperature detector that provides high temperature detection at 135°F — 190°F (57°C — 88°C). IDP-Heat-ROR is a fixed temperature and rate -of -rise thermal detector that uses a thermistor sensing circuit to produce 135°F (57°C) thermal protection. Features • Sleek, low -profile design • Reliable analog communications for trouble-free operation • Age resistant polymer housing • Innovative thermistor sensing circuit • Superior EMI resistance for reliability • Variety of mounting options to meet any application • Dual LED indicators for 360° visibility • Detector transmits signal to indicate maintenance is required • Plug-in mounting provides ease of installation • Optional remote LED annunciator (System Sensor® PN RA100Z) • Tamper -proof feature available on mounting bases • Rotary address switches for fast installation • UL Listed Installation The IDP thermal detectors plug into a compatible IDP -series detector base. Agency Listings MEA 383-02-E Vol. VI IDP -Heat Installed in the B210LP Mounting Base (Base Not Included) Compatibility The IDP -Heat, IDP -Heat -HT, and IDP-Heat-ROR are compatible with the following IDP -series detector bases: • B210LP 6" Mounting Base • B501 4" Mounting Base • B224B1 6" Isolator Base • B224RB 6" Relay Base • B200SR Sounder Base The IDP -Heat -HT, and IDP-Heat-ROR are compatible with the following FACPs: • IFP -2000 / RPS -2000 Intelligent Fire Panel • IFP -1000 Intelligent Fire Panel • IFP -100 Intelligent Fire Panel • IFP -50 Intelligent Fire Panel The IDP -Heat is compatible with the following FACPs: • IFP -2000 / RPS -2000 Intelligent Fire Panel • IFP -1000 Intelligent Fire Panel • IFP -100 Intelligent Fire Panel • IFP -50 Intelligent Fire Panel • IFP -25 Intelligent Fire Panel P/N 350285 Rev E Copyright © 2011 Honeywell International Inc. Compatible FACP RA100Z (Optional) Class A Optional Wiring Wiring IDP -Series Detector Mounting Bases Specifications* Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) Shipping Weight: 4.8 oz (136 g) Electrical Operating Voltage: 15 — 32 VDC ' Standby Current IDP -Heat: 200 pA @ 24 VDC (no communication; LED off) 300 pA @ 24 VDC (one communication every 5 sec with LED enabled) IDP -Heat -HT & IDP-Heat-ROR: 150 pA @ 24 VDC (no communication; LED off) 200 pA @ 24 VDC (one communication every 5 sec with LED enabled) Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature IDP -Heat & IDP-Heat-ROR: -4° — 100°F (-20°C — 38°C) IDP -Heat -HT: -4° — 150°F (-20°C — 66°C) Humidity: 10% — 93% non -condensing Thermal Ratings IDP -Heat: Fixed temperature setpoint 135°F (57°C) IDP -Heat -HT: High temperature heat 135°F — 190°F (57°C — 88°C) IDP-Heat-ROR: Rate -of -rise detection 15°F/min (9°C/min) SILENT KNIGHT by Honeywell Ordering Information IDP -Heat Fixed Temperature Thermal Detector IDP -Heat -HT Fixed High Temperature Thermal Detector IDP-Heat-ROR Fixed Temperature and Rate -of -Rise Thermal Detector Accessories RA100Z XR2B M02-04-00 M02-09-00 XP -4 T55-127-000 BCK-200B Remote LED Annunciator. Detector Removal Tool. A removal and replacement tool for IDP plug-in detectors. Includes the T55-127-000. Replacement Test Magnet. Test Magnet with Telescoping Handle. Extension Pole for XR2B. Extends from 5 — 15 ft. Detector Removal Head. Black Detector Kit. For IDP -series detectors. * Unless otherwise noted, specifications apply to all IDP thermal detectors. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com Made in the U.S.A. Farenhyt 0 by Honeywell SILENT KNIGHT intelligent Devices Intelligent Photoelectric Smoke Detector & Photoelectric Smoke with Thermal IDP -Photo, IDP -Photo -T and IDP-PhotoR The IDP -Photo is a photoelectric smoke detector and the IDP -Photo -T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IFP -series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP -Photo and IDP -Photo -T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the IDP -Photo -T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The IDP -Photon is a remote test capable detector for use with the DNR (W) duct smoke detectors. Features • Sleek, low -profile design • Reliable analog communications for trouble-free operation • Age resistant polymer housing • Dual electronic thermistor design on the IDP -Photo -T • Superior EMI resistance for reliability • Simple field cleaning for code compliance • Variety of mounting options to meet any application • Dual LED indicators for 360° visibility • Detector transmits signal to indicate maintenance is required • Optional remote LED annunciator (System Sensor® PN RA100Z) • Plug-in mounting provides ease of installation • Tamper -proof feature available on mounting bases • Listed for use in duct applications • Rotary address switches for fast installation • UL Listed MEA 225-02-E Vol. V IDP -Photo (Base not Included) Installation The IDP -Photo and IDP -Photo -T plug into a compatible IDP -series detector base. Compatibility The IDP -Photo and IDP -Photo -T are compatible with the following IDP -series detector bases: • B210LP 6" Mounting Base • •6501 4" Mounting Base • B224BI 6" Isolator Base • B224RB 6" Relay Base • B200SR 6" Sounder Base The IDP -Photo and IDP -Photo -T are compatible with the following FACPs: • IFP -2000 / RPS -2000 Intelligent Fire Panel • IFP -1000 Intelligent Fire Panel • IFP -100 Intelligent Fire Panel • IFP -50 Intelligent Fire Panel • IFP -25 Intelligent Fire Panel P/N 350280 Rev E Copyright © 2011 Honeywell International Inc. SLC OUT IN Compatible FACP RA100Z (Optional) +1 — Class A Optional Wiring Wiring IDP-Serles Detector Mounting Bases Wiring IDP -Series Detector Mounting Bases Specifications* Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) Shipping Weight: 5.2 oz. (147 g) Electrical Operating Voltage: 15-32 VDC Standby Current: 250 pA @ 24 VDC (no communication; LED off) 300 pA @ 24 VDC (one communication every 5 sec with LED enabled) Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature IDP -Photo: 32° — 120°F (0°C — 49°C) IDP -Photo -T: 32° — 100°F (0°C — 38°C) Humidity: 10% — 93% non -condensing Other Ratings IDP -Photo -T Thermal: Fixed temperature setpoint 135°F (57°C) Velocity: 0 — 4000 fpm (0 — 20 m/sec) (suitable for installation in ducts) IDP -Photo Insect Screen Hole Size: 0.016" (0.41 mm) nominal )1` SILENT KNIGHT by Honeywell Ordering Information IDP -Photo IDP -Photo -T IDP-PhotoR Accessories RA100Z XR2B M02-04-01 M02-09-00 XP -4 T55-127-000 BCK-200B Photoelectric Smoke Detector Photoelectric Smoke Detector with Thermal (135°F) Photoelectric smoke detector, remote test capable, for use with DNR (W) duct smoke detector Remote LED Annunciator. Detector Removal Tool. A removal and replacement tool for IDP plug-in detectors. Includes the T55-127-000. Detector Test Magnet. Test Magnet with Telescoping Handle. Extension Pole for XR2B. Extends from 5 — 15 ft. Detector Removal Head. Black Detector Kit. For IDP -series detectors. * Unless otherwise noted, specifications apply to IDP -Photo and IDP -Photo -T. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com Made in the U.S.A. Fa ren hyt Addressable Single Action and Dual Action Pull Stations IDP -Pull -SA & IDP -Pull -DA The IDP -Pull -SA is a single action pull station requiring only one motion to activate the station. The IDP -Pull -DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight IFP -series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble-free operation • Braille text on station handle • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System Installation The IDP -Pull -SA and IDP -Pull -DA can be surface mounted to an SB -I/O surface back box or semi -flush mounted on a standard single -gang with a minimum depth of 2.13"(5.40 cm) or double - gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor® PN BG -TR) trim ring if the station is being semi -flush mounted. Xs' SILENT KNIGHT by Honeywell Agency Listings MEA - 67 -02-E Vol. IX For IDP -Pull -DA IDP -Pull -SA IDP -Pull -DA Compatibility The IDP -Pull -SA and IDP -Pull -DA are compatible with the following FACPs: • IFP-2000/RPS-2000 Intelligent Fire Panel • IFP -1000 Intelligent Fire Panel • IFP -100 Intelligent Fire Panel • IFP -50 Intelligent Fire Panel P/N 350286 Rev E © 2010 Honeywell International Inc IN SLC OUT Class A Compatible FACP Class A Wiring. Class B Wiring: Class B 0 3I •I 1 Wiring IDP -Pull -SA & IDP -Pull -DA Pull Stations Specifications* Physical Height: 5.5" (14 cm) Width: 4"'(10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi -Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) )1` SILENT KNIGHT by Honeywell Environmental Operating Temperature 32° — 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing Ordering Information IDP -Pull -SA IDP -Pull -DA Accessories BG -TR SB -I/O Single Action Pull Station Dual Action Pull Station Optional trim ring. Surface backbox, indoor/outdoor. * Unless otherwise noted, specifications apply to IDP -Pull -SA and IDP -Pull -DA. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472- 1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com Made in the U.S.A. SYSTEM SENSOR® Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert®Advance selectable -output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field -selectable candela settings for wall and ceiling strobes and horn/strobes. When installing Advance products, first attach a universal mounting plate to a four -inch square, four -inch octagon or double -gang junction box.The two -wire mounting plate attaches to a single -gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's terminals.The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. SPECTRANert A mV A N C E Features • Electrically compatible with existing SpectrAlert products • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela • Plug-in design • Field selectable candela settings on wall and ceiling units: 15, 15/75, 30,75,95,110,115,135,150,177,185 • Same mounting plate for wall- and ceiling -mount units • Shorting spring on mounting plate for continuity check before installation •Tamper resistant construction • Outdoor wall and ceiling products rated from —40°F to 151°F • Design allows minimal intrusion into the back box • Horn rated at 88+ dbA at 16 volts • Rotary switch for horn tone and three volume selections • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements • Outdoor products rainproof per UL 50 (NEMA 3R) • Compatible with MDL sync module Agency Listings SIGNALING LISTED 54011 55512 53593 APPROVED 3023572 MEA approved MEA452-05-E I 7125-1653186 (indoor strobes) 7300-1653:187 (outdoor strobes) 7125-1653.188 (horn/strobes, chime/strobes) 7135-1653 189 (horns, chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 11/cinch back box, 4 -inch octagon back box or double -gang back box.Two-wire products shall also mount to a single -gang 2 x 4 x 17/8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuir Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field -selectable candela settings including 15,15/75, 30, 75, 95, 110,115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three -pattern and a non -temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 4"/16x 411/16 x 21/s -inch back box.The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) K Series Operating Temperature —40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 9396 non -condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR1 Operating Voltage Rangel 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8 -diameter x 2.5- high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) - 5.61 x 4.71W x 2.5D (142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61x4.7Wx1.3"D(142mmLx119mmWx33mmD) Wall -mount back box skirt dimensions (BBS -2, BBSW-2) 5.91 x 5.0W x 2.2-D (151 nim L x 128 mm W x 56 mm D) Ceiling -mount back box skirt dimensions (BBSC-2, BBSCW-2) ' 7.1 "diameter x 2.25" high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA-WBB) 5.71 x 5.1"W x 2.0"D (145 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA-WBBC) 7.1 -diameter x 2.0" high (180 mm diameter x 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time varying.power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-003 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts UL Max. Horn Current Draw (mA RMS) Candela DC FWR DC FWR Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard 15* 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75* 142 148 77 81 Temporal Medium 44 49 58 69 30* NA NA 94 96 Temporal Low 38 44 44 48 75* NA NA 158 153 Non -temporal High 57 56 69 75 95* NA NA 181 176 Non -temporal Medium 42 50 60 69 110 NA NA 202 195 Non -temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -wire Horn/Strobe, Standard Candela Range (15-115 cd) DC Input 8-17.5 Volts 16-33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High Temporal Medium 137 147 79 90 107 176 194 212 218 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -temporal High 141 152 91 100 116 176 201 221 229 Non -temporal Medium 133 145 75 85 102 163 187 207 216 Non -temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -temporal High 142 161 103 112 126 181 203 221 229 Non -temporal Medium 134 155 85 95 110 166 189 208 216 Non -temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -wire Horn/Strobe, High Candela Range (135-185 cd) DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -temporal High 255 270 303 309 Non -temporal High 233 248 275 281 Non -temporal Medium 242 259 293 299 Non -temporal Medium 219 232 262 267 Non -temporal Low 238 254 291 295 Non -temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at -40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Horn Tones and Sound Output Data Horn and Horn/Strobe Output (dBA) Switch 8-17.5 16-33 24 Volt Nominal Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non -temporal High 82 82 88 88 93 92 100 100 5 Non -temporal Medium 78 78 85 85 90 90 98 98 6 Non -temporal Low 75 75 81 81 88 84 96 92 7t 8t 9t Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2 -wire horn/strobe. AOS -0395-003 SpectrAlert Advance Dimensions 5.98" • 5.05' O ¢O Wall -mount horn/strobes r-2.231 c Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Wall Horn/Strobes P2R*t 2 -wire Horn/Strobe, Standard cdt, Red P2RH* 2 -wire Horn/Strobe, High cd, Red P2RK* 2 -wire Horn/Strobe, Standard cd, Red, Outdoor P2RHK* 2 -wire Horn/Strobe, High cd, Red, Outdoor P2W* 2 -wire Horn/Strobe, Standard cd, White P2WH* 2 -wire Horn/Strobe, High cd, White P4R* 4 -wire Horn/Strobe, Standard cd, Red P4RH* 4 -wire Horn/Strobe, High cd, Red P4RK 4 -wire Horn/Strobe, Standard cd, Red, Outdoor P4RHK 4 -wire Horn/Strobe, High cd, Red, Outdoor P4W* 4 -wire Horn/Strobe, Standard cd, White P4WH* 4 -wire Horn/Strobe, High cd, White Wall Strobes SR*t Strobe, Standard cd, Red SRH*t Strobe, High cd, Red SRK Strobe, Standard cd, Red, Outdoor SRHK Strobe, High cd, Red, Outdoor SW* Strobe, Standard cd, White SWH* Strobe, High cd, White Ceiling Horn/Strobes PC2R* 2 -wire Horn/Strobe, Standard cd, Red PC2RH* 2 -wire Horn/Strobe, High cd, Red PC2RK 2 -wire Horn/Strobe, Standard cd, Red, Outdoor PC2RHK 2 -wire Horn/Strobe, High cd, Red, Outdoor Ceiling -mount horn/strobes 2.00 _j 5.7' //a Wall weatherproof back box Ceiling weatherproof back box Model Description Ceiling Horn/Strobes (contd.) PC2W*t 2 -wire Horn/Strobe, Standard cd, White PC2WH*t 2 -wire Horn/Strobe, High cd, White PC4R 4 -wire Horn/Strobe, Standard cd, Red PC4RH 4 -wire Horn/Strobe, High cd, Red PC4RK 4 -wire Horn/Strobe, Standard cd, Red, Outdoor PC4RHK 4 -wire Horn/Strobe, High cd, Red, Outdoor PC4W 4 -wire Horn/Strobe, Standard cd, White PC4WH 4 -wire Horn/Strobe, High cd, White Ceiling Strobes SCR* Strobe, Standard cd, Red SCRH* Strobe, High cd, Red SCRK Strobe, Standard cd, Red, Outdoor SCRHK Strobe, High cd, Red, Outdoor SCW*t Strobe, Standard cd, White SCWH*t Strobe, High cd, White Horns HR Horn, Red HRK Horn, Red, Outdoor HW Horn, White Accessories BBS -2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White Notes: * Add"-P"to model number for plain housing (no"FIRE"marking on cover), e.g., P2R-P t Add "-SP"to model number for"FUEGO" marking on cover, e.g., P2R-SP # "Standard cd,'refers to strobes that include 15,15/75, 30, 75, 95,110, and 115 candela settings. "High cd, refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in "K" include a weatherproof back box. �`�NSOR® �$ SENSOR' 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2006 System Sensor Product specifications subject to change without notice VISA systemsensorcom for current product Information, including the latest version of this data sheet. A05-0395-003 12/06.61676 O Med 75r4 L _/) to_ LP "rte Equipment Legend Symbol Quantity Part Number Description - Back Box I'M: 1 FPD7024 Fire Alarm Control Panel - Included Mi 7 N/A Fire Alarm Power Supply Included r N/A Remote Annunciator Included RA O9 SD500APS Photoelectric Smoke Detector 4" Square O- 6 SD500AHS Heat Detector 4" Square 3 SD505PS - Manual Pull Station 4" Square F 7 ail Dif 1 P cp Wall Mount fain Strobe 4" Square R1 P2RK Outdoor Hom Strobe Included ® 4Q 1- - PC2R Ceiling Mount Hom Strobe 4" Square CO 451 2 SCR Ceiling Mount Strobe 4" Square 5i3) m BY OTHERS Duct Detector INCLUDED 0 - BY OTHER Water Flow Switch 4" Square ® 0 BY OTHERS Tamper Switch 4" Square 111 WIRE LEGEND A- 18 GAUGE 2 CONDUCTOR 'FPLP' B- 14 GAUGE 2 CONDUCTOR 'FPLP' C- 18 GAUGE 4 CONDUCTOR 'FPLP' D- 14 GAUGE 4 CONDUCTOR 'FPLP' 1 FIRE ALARM PLAN - FIRST FLOOR SCALE: 1 /8"= 1'-0" FIRE ALARM PLAN -MEZZANINE SCALE: 1 / 8"= 1 - 0 3!Qtd in Re Per cie. Letter p,_ SI- :e �- _v`_: > b;' T he ul ila Fire -_ f ,Y,a„_c_ v' ; current city _o cs. -i5`'j tor`, s and Vricrt_:. ,-,L ViGfatifr.S of adopted - _ : as a-:, , :-; _. _ .47for the cf r='s ='r . _fie='aner. rings after Jacz Wi;r VC' --- - a y - - _- y approval. .e Tukwi:C gate: 3 - l I-13 - .zpection by 1 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing (4,.. � a S O4.st ►'�V�/"' b t� Ia o *1,511.1( w N.p Th344-11 -f-AR. okte k /611.1 _ ❑F TumnA F_FaE D7PARTIMTNT Please. 2C6-575-1407 �- e r 1407 and t s» sn !r^ table this 1 t31 ie.. i`- 11 :l NO. f3-F-c��� an e-,Lct ; •_-ress for s,'hu dgivin t 'r+ pp -r- - NOTES: 1) ALL WORK TO CONFORM TO NFPA 72 AND NEC STANDARDS 2) WALL MOUNT HORN STROBES AND STROBES TO BE MOUNTED 80"-96" AFF OR 6" BELOW CEILING WHICHEVER IS LOWER. - 3) PULL STATIONS TO BE MOUNTED: A) 48" - 53" AFF B) WITHIN 5' OF THE DOOR. 4) FIRE ALARM CONTROL PANEL TO BE ON DEDICATED CIRCUIT 5) WIRING METHOD TO BE OPEN CABLE UNLESS BELOW 7' AND EXPOSED, THEN IT WILL BE CONTAINED WITHIN CONDUIT. 6) SMOKE DETECTORS TO BE INSTALLED: A) MORE THAN 36" FROM ANY HVAC DIFFUSER B) NOT IN CLOSE PROXIMITY TO FLUORESCENT LIGHTING C) AT LEAST 6" DOWN FROM PEAK IN SLOPED CEILING 7) ALL JUNCTION BOXES, MUD RINGS AND BOX COVERS TO BE PAINTED RED (INSIDE AND OUT). 8) EXTERIOR HORN STROBES TO BE MOUNTED IN THE TOP 2/3 OF THE BUILDING STRUCTURE FACING THE ANTICIPATED FIRE DEPARTMENT ACCESS ROAD. Battery Calculation Worksheet (all currents stated in mA) Device Description IPP -50 - mA Draw each 8 of Devices Stand By Alarm System Devices 200 - 325 Total mA Draw Stand By Alarm 200 - 325 Initiation Devices /Auxiliary Devices 4,5 '• a .....a{:. 05 0.5 4.5 1.5 - Device Totals 2i:_ 05 0.5 PC2R @ 30cd SCR@ 115cd P2RK 0 75cd Notification Appliances (list al) NAC 1 (NORTH SIDE) _ - PC2R 115cd SR@ 15cd PC2R 130cd Circuit 1 Totals .: 5 NAC 2 (SOUTH SIDE) 97 0 194 205 0 410 176 0 176 0 - 780 210 6 97 -: 210 66- - 97 PC2R30cd PC2R @ 30cd 7 : .. 97 -97 494 Unused Circuit 3 Totak:';.:`.::>':_::. NAC4 Circuit 4 Totals Notification Appliances Total Current WOO; Design Voltage 24 0' 0 0 - Voltage Drop Calculation Worksheet circuital - - -- — - _- - -- - — Voltage Drop Length _ Amp Draw V4re Gauge Loss per 100' = Voltage Drop Voltage at EOL % 125 __4,..__111-,10.78 14 039 -- -- 0.49 23.51 2.05% Circuit 42 Length Amp Draw =Wre Gauge Loss per 100' Voltage Drop Vo tage at EOL 125-_� 0.373 14--'019- 0.24 2376 Voltage Drop 0.98% Circuit 82 Length 125 Voltage Drop Amp Draw Wire Gauge Loss per 100' = Voltage Drop Voltage at EOL % _._ 4.194 14 __ 010 - - --- ,:i::: 0.12 ' 23.88 ::- 051 % Summary Section Required Standby Hrs. Alarm Sounding Minutes Total System Standby mA Total System Alarm mA Total System Standby Ah Total System Alarm Ah Available 24 5 210.5 1682.5 5.052 0.140 Min. Ah Battery Derating Factor Battery Ah wP, 6000 5.192 20% 6231 :.: ui'6kCH.. 6000 7 7 7 / 3 - MA:- 7 2013 (4 NORTH ELEVATION SCALE: 1 / 8" = 1' - 0" 5 NOTES SCALE: NTS BATTERY CALCULATIONS SCALE: NTS FIRE cc t'2V5 Froula Alarm Systems, Inc. 861 Industry Drive Tukwila, WA 98188 206-575-1962 DESIGNER OF RECORD Kristopher Conner NICET IV 69311 F, ` cin J.4g m J Dco Zz Cn Q(jQ> J 17.o -i D Lo 0 LO \-b F- 0 O DATES SUBMITTAL: REVISION: SHEET TITLE FIRE ALARM PLAN SHEET NUMBER - FA -1 r!...,71/.111.1,.11,1, `J` SLOPED CEILING 9' TO 8' l L 30 cd ENTRAL BEAM 9' FLAT CEILING SLOPED CEILING 8' TO 12' .r 75cd 75cd 9' FLAT CEILING FIRE ALARM PLAN SCALE: 1 / 4" = 1' - 0" Equipment Legend Symbol Quantity Part Number Description Back Box 1 IFP -50 Fire Alarm Control Panel Included ■ 0 N/A Fire Alarm Power Supply Included WWII 0 N/A Remote Annunciator Included RA O1 IDP -PHOTO Photoelectric Smoke Detector 4" Square O0 IDP -HEAT Heat Detector 4" Square 1 IDP -PULL -SA Manual Pull Station 4" Square F 1 P2R Wall Mount Hom Strobe 4" Square SR Wall Mount Strobe 4" Square t2' RI1 P2RK Outdoor Hom Strobe Included 6 29 PC2R Ceiling Mount Hom Strobe 4" Square 0 38 SCR Ceiling Mount Strobe 4" Square WIRE LEGEND A- 18 GAUGE 2 CONDUCTOR 'FPLP' B- 14 GAUGE 2 CONDUCTOR 'FPLP' C- 18 GAUGE 4 CONDUCTOR 'FPLP' D- 14 GAUGE 4 CONDUCTOR 'FPLP' NOTES: 1) ALL WORK TO CONFORM TO NFPA 72 AND NEC STANDARDS 2) WALL MOUNT HORN STROBES AND STROBES TO BE MOUNTED 80"-96" AFF OR 6" BELOW CEILING WHICHEVER IS LOWER. 3) PULL STATIONS TO BE MOUNTED: A) 48" - 53" AFF B) WITHIN 5' OF THE DOOR. 4) FIRE ALARM CONTROL PANEL TO BE ON DEDICATED CIRCUIT 5) WIRING METHOD TO BE OPEN CABLE UNLESS BELOW 7' AND EXPOSED, THEN IT WILL BE CONTAINED WITHIN CONDUIT. 6) SMOKE DETECTORS TO BE INSTALLED: A) MORE THAN 36" FROM ANY HVAC DIFFUSER B) NOT IN CLOSE PROXIMITY TO FLUORESCENT LIGHTING C) AT LEAST 6" DOWN FROM PEAK IN SLOPED CEILING 7) ALL JUNCTION BOXES, MUD RINGS AND BOX COVERS TO BE PAINTED RED (INSIDE AND OUT). 8) EXTERIOR HORN STROBES TO BE MOUNTED IN THE TOP 2/3 OF THE BUILDING STRUCTURE FACING THE ANTICIPATED FIRE DEPARTMENT ACCESS ROAD. \`1) LEGENDS %SCALE: NTS NOTES SCALE: NTS Device Description MP -50 1lnueed Unused 8 of Devices /scam Devices � T mA Draw each Total mA Drew - Stand By Alarm ......_ Stand By AMrm 200 sz5 o;.. o 200 i0 aaa o' 0 Total System Current 1 200 FOP -HEAT IDP -PULL -SA Unused Initiation Dov c r FwxtLnry Davfcas 6 Oa 0 D 0.5 0.5 0 2,5 0.6 0 325 I 2.5 0 --. Device Totals :........ _...i6 3- Notification Appliances (fist ell) NAC 1 8.11.30cd Unused 0 0 0 0 314 96 0 Circuit 1 Totals O NAC 2 Unused fl 0 410 0 C#quk 2 Totals 41.., :; 0 . 0 0 --- O -- untried ::. Clrcult 3 Totals• MAC 4 • Circuit 4 Totale >-:0 0 0 :.0- 0 0_ 0 Notification Appliances Total Design Voltage 24, VoltageDropCalculation ! ortt"heat Circuital Length 100 Amp Draw 0.41. Wire Gauge 1 Voltage Drop Loss per 100' Voltage Drop Vo"ege at EOL % 0.21 °:-. 021 -`--23.79 0.66% Circuit X2 Length Amp Draw .. Wire Gauge Loss per 100' Voftege Drop Voltage Drop Voltage at EOL % .000 . _: 24:00. -0.00% Circuit #3 Length Amp Draw Wire Gauge Loss per 100' Voltage Drop 14 0=00 0.00 Voltage Drop Voltage at EOL 15 24.00 2- 0.00% Circuit X4 Length ,4np Draw Wire Gauge 0 14 Voltage Drop Loss per 100' Voltage Orap : Voltage at EOL 0.00 0.00 _.. - 24 00 0.00% Standby Hrs. Summary Section Required 24 Alarm Sounding Minutes Total System Standby mA Total System Alarm mA Total System Standby Ah Total System Alarm Ah Ah Battery Derating Factor Battery Ah IPSIESS 5 203 738 4.872 0.062 4.934 20% 5.920 Available 6000 6000 7 7 7 *40 C1` EAST ELEVATION SCALE: 1 / 8" = 1' - 0" BATTERY CALCS SCALE: NTS Froula Alarm Systems, Inc. 861 Industry Drive Tukwila, WA 98188 206-575-1962 DESIGNER OF RECORD Kristopher Conner NICET IV 69311 s 0 D zo (/) J >- co D<2 I-- 0OT) D Z °<( Lt1 rs � J F." < Q 2 0 Dc/) H OW 0 (00 DATES SUBMITTAL: REVISION: SHEET TITLE FIRE ALARM PLAN SHEET NUMBER FA -2