HomeMy WebLinkAboutPP - 14223 TUKWILA INTERNATIONAL BLVD - JUBA RESTAURANT - PERMITS AND PLANS14223 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS 10-F-277 11-H-112 11-S-130 SITE LOCATION j ,-2,3 o Y ^ T) 1 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Z23 King Co. Asseesss rr''s ax No.: Site Address: �V�—W�QrrI4't "0"�SuiteN-umber: Floor: \) \ `erC e ' Ll- C �: o �S1" Wr-5. ' Tenant?PPD Tenant Name: V New ❑ - Yes ❑ - No Property Owner's Name: ��tt--CJS LL�LLC_ Mailing Address: SLD C�'r T l l s"'' C (NA.-- & \L lbo k; p 1-3Cn LVA a State Zip City CONTACT PERSON -if there are questions about the submittal. Name: LkIYIbn11- W\a.' Day Telephone: Company Name: F,^SI «`fie-rrotcC-Ti‘d\ I_ Mailing Address: 1o7 -I 2 Z -t S P v� St Sv't$60M' f E-mail Address: ! �-� f�lL� k'b�✓rvk I' Carcity Fax Number: i 4S�eC ( ip' Valuation of Project (contractor's bid price): $ 2 1.00 Scope of Work (please provide detailed information): i \ V0 %y^A tb C° T t 1i✓\C11t --17.11"`•v o V Yt^t I T A r\c L b (AFiA cr t_ PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNED OR AUTHO . ED AGE Signature: Print Name: Plan Permit App.doc 5/14/10 Date: ‘- ` I Day Telephone: 206. t TFD FP Form 8 CORRECTION NOTICE/REINSPECTION FEE Inspector: F24 5: ` Permit number: TUKWILA FIRE MARSHAL'S OFFICE Office: 206-575-4407 Fax: 206-575-4439 Email: Fire Marshal(�tukwilawa.gov Business Name: -3 J ugocr Pg Type of Inspection:1.n Location Address: /4/v.2,3 Te Date : 2/ z-4-65 A//C Contact Person :! ` Ar2...2:50,fr) \ A es,wY e No. x-- .4)1, 244 4 �s�'j ACTION REQUIRED C- g -r- f(07 D r N spt-voo13 01J 240 . c'd.sisil,E ZiN6< f14 -s rev mva 4/1-eltr ,9„ro nve-ros Pret-147,644,61J7 wefivte- s_c.4.-p vc6:6 Few._ .74r/1 tigEildi ainPirl) 04?/77E-7- (/•/ nr-a-itV a._ -1 k6 / ttke,AAk'e6 ITEMS ARE REQUIRED BY : 1 l75 Y RESULT IN THE ISSUANCE OF A C NAL CITATION/TICKET. CORRECTION I, HEI, BOVE FAILURE Signatur Billing/Mailing Address : Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Rein Fee2.doc Revised 6/17/14 T.F.D. Form F.P. 100 z •a FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Juba Center Phase 2 14227 Tukwila Intl BI Permit No.: 11-S-130 Date: June 15, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206)971-8718 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. 'SAFETY TEA — Global Project Values: Project Name: project Address: Prepared By: Juba Center @ Riverton Heights 1 14227 Tukwila Int. Blvd St#101 1 The Safety Team, Inc Date:17/5/2011 Standby Hours: Alarm Mins: Derating Factor: Voltage Drop Warning Threshold % .j 10 24 1.2 Panel ID: Location: Model: FX -350 Max Circuit Current: 1.5 Amps Volts: 24 VDC Max Panel Current: 5 Amps Building FACP Back Exit Hallway Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Circuit Name Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 1 Phase 1 0.000 1.405 #16 Solid 4.02 150 1.21 18.71 8.31% 2 Phase 2 0.000 0.606 #16 Solid 4.02 100 0.80 19.91 2.39% 3 Not Used 0.000 0.000 #16 Solid 4.02 0.00 20.40 0.00% 4 Not Used 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Aux Not Used 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Panel + Addressable Load 0.390 1.260 2.011 (Amps) Total Output Power Required Total Standby Current (Amps) 0.390 3.271 Total Alarm Current (Amps) of 72 degrees F. Because of no differential was made. Standby Time In Hours 24 0.083 Alarm Time in Minutes / 60 (5 Mins) Total Standby AH Required 9.360. 0.273 Total Alarm AH Required Total Combined AH Required ,, 9.63 Wire resistances are based upon an ambient temperature the minimal difference between solid and stranded wire Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 11.56 (2) 12V 12AH Batteries Already Installed Prepared by Gabe Orozco 7/5/2011 Page 1 i k`1."E SAFETi' 4"'>f 4. M�E.AaIntC. Circuit Configuration Project Information Project Name: Juba Center @ Riverton Heights Prepared By: The Safety Team, Inc Project ID: 14227 Tukwila Int. BI Date: 7/5/2011 d: Ckt. Number: 1 Panel ID: Building FACP Ckt. Name: Phase 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 Wheelock RSS 95cd (Strobe Only - Ceiling) 0.000 0.249 0.000 0.498 2 Wheelock AS-95cd (Horn/Strobe - Ceiling) 0.000 0.186 0.000 0.372 1 Wheelock AS-75cd (Horn/Strobe - Ceiling) 0.000 0.145 0.000 0.145 6 Wheelock RSS 15cd (Strobe Only - Ceiling) 0.000 0.065 0.000 0.390 0.000 0.000 Totals ' 0:000 . 1;4.05` CM. Number: 2 Panel ID: Building FACP Ckt. Name: Phase 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 Wheelock AS-95cd (Horn/Strobe - Ceiling) 0.000 0.186 0.000 0.186 1 Wheelock AS-75cd (Horn/Strobe - Ceiling) 0.000 0.145 0.000 0.145 2 Wheelock RSS 30cd (Strobe Only - Ceiling) 0.000 . 0.105 0.000 0.210 1 Wheelock RSS 15cd (Strobe Only - Ceiling) 0.000 0.065 0.000 0.065 0.000 0.000 Totals ° . 0.000 . 0,.606 Ckt. Number: 3 Panel ID: Building FACP Ckt. Name: Not Used Max Circuit Current: 3 Amps Qty Device. Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals .. ,0:000:' , .0.000 Ckt. Number: 4 Panel ID: Building FACP Ckt. Name: Not Used Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000. 0:000 Prepared by Gabe Orozco 7/5/2011 Page 1 COOPER Notification Series AS Audible Strobe Appliances and Series AH Audibles SERIES AS Description The Wheelock patented 2 -wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi -candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi -candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM,DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. E5946 S5391 THE CRY0/111 NFIV YORK 151-92-E 7125-0785131 SERIES AH Features • Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information • ADA/NFPA/UFC/ANSI Compliant • Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi - Candela models) or 1575cd (single candela model) • Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (multi -candela ceiling models) • Selectable Continuous Horn or Temporal (Code 3). • 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones • Patented 2 -Wire Audible Strobe Appliance. • Patented Universal Mounting Plate • Weatherproof models are available for outdoor use • Strobes produce 1 flash per second over the regulated voltage range • 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage • Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires For Weatherproof Series AS, See Datasheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range'. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). • Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (cd) AS-24MCW 24 16.0 - 33.0 15/30/75/110 AS-24MCCH 24 16.0 - 33.0 115/177 AS -241575W 24 16.0 - 33.0 15 (75 on Axis) AS -121575W 12 8.0 -17.5 15 (75 on Axis) AS-24MCC 24 16.0 - 33.0 15/30/75/95 AS-24MCWH 24 16.0 - 33.0 135/185 ASWP-2475W 24 16.0 - 33.0 75 @ -31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Description Volume Reverberant dBA Per UL 64 @10ft. Anechoic dBA @10 ft. Continuous Horn High 91 99 Medium 88 95 Low 83 90 Code 3 Horn High 87 99 Medium 84 95 Low 79 90 Table 3: Average RMS Current 24 VDC Models Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models AH -24 AS -241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd High (99) dBA 24 vdc 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 UL max* 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 Med (95) dBA 24 vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 UL max* 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 Low (90) dBA 24 vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 UL max* 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 12 VDC Models Audible Wall Mount Audible Strobe AH -12 AS -121575W High (99) dBA 12 vdc 0.163 0.260 UL max* 0.192 0.320 Med (95) dBA 12 vdc 0.076 0.195 UL max* 0.108 0.275 Low (90) dBA 12 vdc 0.039 0.175 UL max* 0.058 0.265 Table 4: Average Current* (AMPS) For Series ASWP# Voltage High dBA Setting (99) dBA Medium dBA Setting (95) dBA Low dBA Setting (90) dBA 24.0 VDC 0.128 0.105 0.098 UL Max* 0.168 0.155 0.150 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams* SERIES AS APPLIANCES NON -SYNCHRONIZED FROMO PRECEDING❑ +_ APPLIANCE❑ OR FACP❑ +❑ TO NEXTO 8PPLIANCE❑ OR EOLR❑ SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12/24-8CP and PS-12/24-8MP E❑ A❑ CO P❑ OUTPUTS: 1-40 4-CLASSD .E.0 DEC 2 -CLASS: .,A.D ASO As: 411 ASD , Series PS-12/24-8CPD cr PS -12/24 -BMP EOLRJ SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE F❑ A❑ CO P❑ SMEI +:STROBE: StrobsO 0 DSTROBED NACO circuit: 0 II Eudib EOLR: Audible: -hudib NACO Circuit: Mel e❑ e❑ SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE D6.6 P' 1F 1.994011 VIOIIAL PlO NAL 604WI' PP?VP ,evrc ,A r MI rIMY lI wAVl�l LF • AVt��i� ,002 0 r 4k Truro —tI SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES F❑ A❑ C❑ PO Audible NAC Cu #10 Strobe NAC Cir. Sync: Audible NAC m +fl m - liDSM #20 Strobe NAC Audible NAC i . }Sync: Sync: Strobe NAC C_r�; DSM Interconnecting wiring shown. Maximum twenty (20)D *1.1WiAMCt APPNWISL Specifications and Ordering Information For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS-24-8MC. Model Number Order Code Strobe Candela Non- Sync y Sync wISM, DSM or PS-24-8MC 24 VDC 12 VDC Wall Mount Ceilin Mount Mounting Options*** Agency Approvals UL MEA CSFM FM BFP AS-24MCW-FR 9024 15/30/75/110 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-24MCW-FW 9025 15/30/75/110 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-24MCWH-FR 3468 135/185 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X * AS-24MCWH-FW 3469 135/185 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X AS -241575W -FR 7405 15 (75 on Axis) X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS -121575W -FR 7410 15 (75 on Axis) X X - X X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-24MCC-FR 3161 15/30/75/95 X X X - - X A,B,D,E,F,G,H,J,N,O,R,X X X X X * AS-24MCC-FW 3162 15/30/75/95 X X X - - X A,B,D,E,F,G,H,J,N,O,R,X X X X X * AS-24MCCH-FW 3467 115/177 X X X - - X A,B,D,E,F,G,H,J,N,O,R,X X X X X * ASWP-2475W-FR** 9012 75 @ -31°F X X X - X - I (see Data Sheet S9004) X X X X X AH -24-R 7892 - X X X - X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH -24-W 7893 - X X X - X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH -12-R 7891 - X X - X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH -12-W 7894 - X X - X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH-24WP-R** 7416 - X X X - X X K X X X X AH-12WP-R** 7415 - X X - X X X K X X X X **For Weatherproof Series AS/AH specifications see data sheet S9004. ***Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. *PENDING Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi - Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non -synchronized flash -rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single -gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. NEMA Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S8100 AS/AH 10/07 NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P: 800-631-2148 F: 732-222-8707 www.coopernotification.com Cooper Notification is Wheelock® FL Location 7565 Commerce Ct. Sarasota, FL 34243 P: 941-487-2300 F: 941-487-2389 11.4 ,:si VA Location 2009 North 14th St., Ste. 510 Arlington, VA 22201 P: 877-459-7726 F: 703-294-6560 SAFEPATH` WAVES COOPER Notification 11111.1 COOPER Notification Series RSS and RSSP Strobes and Strobe Plates Series RSS Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi -candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi -candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi -Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. MEA S5391 151-92-E 7125-0785:141 7300-0785:154 Series RSS Series RSSWP RSS Round Features • Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information • ADA/NFPA/UFC/ANSI compliant. Meets OSHA 29 Part 1910.165 • Wall mount Multi -Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. Single Candela models are available in 1575cd • Ceiling mount Multi -Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Round or Square) • Strobes produce 1 flash per second over the regulated voltage range • 12 and 24 VDC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage • Synchronize using the Wheelock sync modules or panels with built-in Wheelock Patented Sync Protocol • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weatherproof Series RSS See Datatsheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). • Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP 24VDC Models RSS/RSSP - Wall Mount Ceiling Mount 241575W 24MCW 24MCWH 24MCC 24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS/RSSP 24VDC Models RSS/RSSP Wall Mount 121575W 12 vdc 0.152 UL max* 0.255 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET -1010/1080, E70, ET70 Chimes CH70 SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT STROBE NAC CIRCUIT OUT DSM TROBE NAC CIRCUIT RETURN Wiring Diagrams* SERIES RSS/RSSP APPLIANCE FROM + TO NEXT PRECEDING APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 Sync Strobe NAC Cir. — 0+ -�0 - F A C P DSM #2 Strobe NAC Cir. Sync 0 + 0 - DSM #3 Strobe NAC Cir. Sync 0 + 0 - Mat RS1141 DSM Interconnect ng wiring shown. Maximum of twenty (20) 1. STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM APPLIANCE PRECEDING - -- + OR EOLR APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP STROBE AUDIBLE STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM + PRECEDING APPLIANCE OR - + TO NEXT APPLIANCE FACP OR EOLR FROM + - — f — — — — — - + TO NEXT PRECEDING STROBE OR STROBE, SYNC - - — ti 1 — — — — — EOLR MODULE, POWER I I SUPPLY OR FACP STROBE APPLIANCE " For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer PS-24-8MC. Specifications and Ordering Information SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT F A C P SM Strobe NAC Circuit + STROBE 0 STROBE 0 U+Audible EOLR -Audible SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH PS-12/24-8CP or PS-12/24-8MP Series PS-12/24.8MP F A P OUTPUTS 1-4 4 -CLASS OR 2 -CLASS Series PS-12/24-8MP EOLR Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting Options*** Square or Round Agency Approvals UL MEA CSFM FM BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15 (75 on Axis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FW 7788 X - X 15 (75 on Axis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FR 7476 X - X 15 (75 on Axis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15 (75 on Axis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X * RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X * RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCWH-FW 3464 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP-2475W-FR** 9013 X - X 180@ 77°F 75@ -31°F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X ' RSSP-2475W-FW** W 3034 X - X 180@ 77°F 75@ -31°F X X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSP-121575W-FR 7798 X - X 15 (75 on Axis) - X X - D,E,Z Square X X X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X - X 15 (75 on Axis) - - X - D,E,Z Square X X X X X All models sync with Wheelock SM, DSM or PS-12/24-8CP or PS-12/24-8MP. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. *PENDING Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi -Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non -synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single - gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi -Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. NEM Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S0410 RSS/RSSP 02/08 NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P: 800-631-2148 F: 732-222-8707 www.coopernotification.com Cooper Notification is Wheelock' FL Location 7565 Commerce Ct. Sarasota, FL 34243 P:941-487-2300 F: 941-487-2389 VA Location P: 877-459-7726 F: 703-294-6560 SAFEPATH" WavE� COOPER Notification MircomTM ALPHA INTELLIGENT ADDRESSABLE MODULES MIX -100 SERIES MIX -101P L. • 4.I1atr • MIX-100S AIM 000101.4. c MIX-10OP MIX -100X Description Mircom's Alpha Series Intelligent Addressable Modules are designed to meet a wide range of applications. The monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, waterflow switches, conventional smoke detectors and more. An eight position dip switch allows for the address setting of the device and the wiring class/style of the devices that are connected to the module. All modules mount in a standard 4" x 4" x 2 1/8" junction box. Intelligent Addressable Priority Monitor Module (MIX-10OP) The Intelligent Addressable Priority Monitor Module (MIX-10OP) provides an address for a group of UL/ ULC Listed normally open (N.O.) initiating devices, such as heat detectors, beam smoke detectors, 4 - wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-10OP is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX-10OP has an activated red LED. Features • Designed to meet a wide range of applications • For use with the FX -350 Series Fire Alarm Control Panels • Fast response time • Priority Interrupt feature on monitor modules • Monitor modules can be wired as a Class A (Style D) or Class B (Style B) • Each module can be addressed from 1 to 126 • Eight position dip switch for address setting • Red light indicator • Modules mount in standard 4" junction box Intelligent Addressable Priority Mini -Monitor Module (MIX -101P) The IntelligentAddressable Priority Mini Monitor Module provides an address for a group of UUULC Listed Normally Open (N.O.) initiating devices, such as heat detectors, projected beam smoke detectors, 4 -wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX -101P is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX -101P has an activated red LED. Intelligent Addressable Relay Module (MIX -100R) The IntelligentAddressable Relay Module connects to the same loop as the initiating devices and provides two isolated sets of Form -C contacts to control a variety of normally open or normally closed contact applications cuch as fan operation and door closures. The MIX -100R has an activated red LED which follows the state of the relay contacts. S5434 S5434 7150-1477:156 CATALOG NUMBER, 5675 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Intelligent Addressable Supervised Control Module (MIX -100S) The MIX -100S Control module provides supervised monitoring of wiring to signal devices that require an external power supply to operate, such as horns, strobes, bells or speaker isolators. Conventional signals will require a 24 VDC power source and speakers will require an audio input. The red LED will illuminate when the module is activated. The module is capable of Class A (Style Z) or Class B (Style Y) supervision. Specifications General Specifications Operating Voltage 16-28 VDC Communication Class A (Style D) or Class B (Style B) switch selectable Relative Humidity 0% to 95% (No condensation or icing) MIX-10OP and MIX -101P Current Consumption 600 pA Alarm Current 4.6 mA (LED on) Dimensions MIX-10OP 4.0"Wx 4.0" H x 1.3" D MIX -101P 3.0"Wx 2.0"H x 0.75"D Weight MIX-10OP 3.0 oz. (85.8g) MIX -101P 1.5 oz. (42.6g.) MIX -100S Current Consumption 1 mA Source Power Signals 24 VDC regulated Speakers 70.7 V RMS Ratings 2A @ 30VDC, 0.6A @ 125VAC Dimensions 4.0" W x 4.0" H x 1.3" 0 Weight 3.0 oz. (85.8g) Ordering Information Fault Isolator Module (MIX -100X) The MIX -100X Fault Isolator Module is used to protect the system against wire -to -wire short circuits on the analog loop. The modules should be spaced between groups of sensors or modules in a loop to protect the rest of the loop. In the event of a short circuit between any two fault isolator modules, both modules immediately switch to an open circuit condition and isolate any group of sensors between them. The remaining units on the circuit will continue to operate in a normal fashion (must be wired in Class 'A' or Style 6). Operating Temperature 0°F to +155°F (-20°C to +70°C) HousinglCover Plate Finish White Polycarbonate MIX -100X Current Consumption 35pA at 24V Max. Line Current 1 Amp Line ResiStapee 0.2 ohm Dimensions 4.0" W x 4.0" H x 1.3" D Weight 3.0 oz. (85.8g) MIX -100R Current Consumption 250 pA Ratings 2A @ 30VDC, 0.6A @ 125VAC Dimensions 4.0" W x 4.0" H x 1.3" D Weight 3.0 oz. (85.8g) Model Description MIX-10OP Intelligent Addressable Priority Monitor Module MIX -101P Intelligent Addressable Priority Mini Monitor Module MIX -100R Intelligent Addressable Relay Module MIX -100S Intelligent Addressable Supervised Control Module MIX -100X Fault Isolator Module Mircom��� Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 NOT TO BE USED FOR INSTALLATION PURPOSES. U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com Distributed by: ISO 9001:2008 / �� REGISTERED \� CAT. 5675 Rev. 1 THESAFE`i `Y EAMINc. Jlf obal Project Values. Project Name: Droject Address: Prepared By: Date: Juba Center @ Riverton Heights 14227 Tukwila Int. Blvd St#101 The Safety Team, Inc 8/12/2011 Standby Hours: Alarm Mins:, Derating Factor: Voltage Drop Warning Threshold % . 24 5 1.2 10 Panel ID: Location: Model: FX -350 Max Circuit Current: 1.5 Amps Volts: 24 VDC Max Panel Current: 5 Amps Building FACP Back Exit Hallway Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Circuit Name Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 1 Phase 1 0.000 1.405 #16 Solid 4.02 150 1.21 18.71 8.31% 2 Phase 2 0.000 0.650 #16 Solid 4.02 100 0.80 19.88 2.56% 3 Not Used 0.000 0.000 #16 Solid 4.02 0.00 20.40 0.00% 4 Not Used 0.000 _ 0.000 #12 Solid 1.59 0.00 20.40 0.00% Aux Not Used 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Panel + Addressable Load 0.390 1.260 2.055 (Amps) Total Output Power Required Total Standby Current (Amps) 0.390 3.315 Total Alarm Current Amps) ure of 72 degrees F. Because of no differential was made. Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 9.360 0.276 Total Alarm AH Required Total Combined AH Required 9.64 Wire resistances are based upon an ambient tempera the minimal difference between solid and stranded wire Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 11.56 (2) 12V 12AH Batteries Already Installed Prepared by Gabe Orozco 8/16/2011 Page 1 • THESAFETY Circuit Configuration 'TEA M'Nc. Project Information Project Name: Juba Center @ Riverton Heights Prepared By: The Safety Team, Inc Project ID: 14227 Tukwila Int. BI Date: 8/12/2011 d Ckt. Number: 1 Panel ID: Building FACP Ckt. Name: Phase 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 Wheelock RSS 95cd (Strobe Only - Ceiling) 0.000 0.249 0.000 0.498 2 Wheelock AS-95cd (Horn/Strobe - Ceiling) 0.000 0.186 0.000 0.372 1 Wheelock AS-75cd (Horn/Strobe - Ceiling) 0.000 0.145 0.000 0.145 6 Wheelock RSS 15cd (Strobe Only - Ceiling) 0.000 0.065 0.000 0.390 0.230 0.000 0.000 Totals 0.000 1.405 Ckt. Number: 2 Panel ID: Building FACP Ckt. Name: Phase 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 Exceder HS -C 150 cd 0.000 0.230 0.000 0.230 1 Wheelock AS-75cd (Horn/Strobe - Ceiling) 0.000 0.145 0.000 0.145 2 Wheelock RSS 30cd (Strobe Only - Ceiling) 0.000 0.105 0.000 0.210 1 Wheelock RSS 15cd (Strobe Only - Ceiling) 0.000 0.065 0.000 0.065 0.230 0.000 0.000 Totals 0.000 0.650 Ckt. Number: 3 Panel ID: Building FACP Ckt. Name: Not Used Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: 4 Panel ID: Building FACP Ckt. Name: Not Used Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Prepared by Gabe Orozco 8/16/2011 Page 1 f FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Juba Center 14227 Tukwila Intl BI Suite 101 Permit No.: 11-H-112 Date: May 24, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Nozzle heights above appliances to be per manufacturers installation guidelines. • Fryers shall be installed with at least a 16 inch space between the fryer and surface flames from adjacent cooking equipment or a minimum 8,inch high steel or tempered glass baffle plate shall be installed between the appliances. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatically activate the exhaust system whenever cooking operations occur. The activation of the exhaust system shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. • The suppression system manual pull station shall be located no closer that 10 ft. and no farther than 20 ft. from the cooking equipment and be placed at a height of 42 to 48 inches above the floor. • The inside lower edge of the hood shall overhang or extend a horizontal distance of not less than 6 inches beyond the edge of the top horizontal surface of the appliance on all open sides. The vertical distance between the front lower lip of the hood and such surface shall not exceed 4 feet. • If cooking appliances are wheeled, the appliance wheels shall be set in tracks permanently mounted to the floor to ensure appliance is returned to original location if moved for cleaning or maintenance. NOZZLE HEIGHT42 IN • PIP SIZE 1/2 Rotaliflowipoint Amertex Ikp 4.:75 fire uppre:ssion Isystern toll 300 Juba center 1.4227Tukwila int bive it WA1981168 hood 12' DUCT 10x31 FUSIBLE LINKS 450 Amerex kp4.75 maximum flow point 14 1641616416 11982 11982 Cj 11982 ,11982 11982 cA N mm N f� 1 co r— RANGE MECHANICAL GAS VALVES 18x36 RANGE broiler griddel FRYERE FRYERE RANGE 12x24 24x24 24x24 16X16 16X16 24x24 nozzle hight42E ccodking(equipment iundderttheihoodsttill!Bhutto'ff\When§ystemiis,actuatedZimakeiwpainunit and cgas!Shutwaluettoffire suppression lsystem (Shall Ibetconnected ttotthelflrezalarm!system Installed by Frank fire portection Inc 206 229 5245 MANUAL PULL 48" HEIGHT IK(OLASS IRIRE LEX1I I PAID MAY 18 2011 TUKWILA ARE - AMEREX KP RESTAURANT SYSTEM NOZZLE APPLICATION CHART CO CO F 2 a. OD CD TF a. - CO F qs. 2 a. co CO CO F 2 a. CO p. toe 2 cc .tzL v a -.-. 0:1 - co ..:r 48 in. -- co -os • c.1- -4:1- 48 in. 50 in. 47 in. 19 in. 6 r(Do. cvs 50 in. E .__ U) E .... co -4- 501n. 6 ..... o U) E ___ ,:t• Nr 48 in. I . E CD co 6 CO c,) 6 C Nt 6 as NI- 6 •a• NI- Max. Diagonal .._. co 6 , - i I 37.2 in. i [ 55.9 in. .NI Protection is not limited to the Items listed on this chart. Modulizing larger appliances Is an acceptable practice. See your AmerexKP Manual for additional information. Height Ec• COD 01) CO:...-_ 01 ,..... 1,- T- c ..... C) 04 44 in. 36 in. 40 in. et ,- (0 c4 00 ,- 40 in. EEE CD co CO00 (1)'- U) EE ._ c0 ,- EEE6E .— CO03 ,- . ._ CV ,- _ C4 ,- ...... CO ,- ._ COOD T-- ._ CD T- Length Unlimited Unlimited Unlimited -a. G) E == C I- Unlimited , Urilimited .c Th ..... -,1 .6 cs) ..c- 25 3/8 in. 25 3/8 in, . cac .... CO v- 28 in. 24 in. 24 in. . cc ... (‚4 •qt• . _ (0 vs 24 in. 4-7 depth O0 co C4 •ct c0 -1- E ..s.. CD N et CM: et 04 e- CO e- CO et CV 6 >, CO CV E :•-•,.. CO C4 E - CD N Length 0 . •&- Diameter , E ._ CD *,-- i E ._ N. CO E ._ CO Nt = :i. ., CD N-- T- y- CCCCC EE CM 14-24 dia. cEE• 01) 0/ CO 0 01 cc-- CM 04.'4- 04 24% in. ECCE oo 't ,o- CM •::r CV et C4 Width 4 ft. 1... 4:0 es ig E 4) a. * E CD I 100 in. 150 in. I Flow Points (NI csj 04 :•_:,,4 y- y- y- y- y- cy T .rm CV C4 T". :....g 'V C... T..' CM ..tt :=4: V.' ,.: V.".. :P.. 1.... Flow Points !'m Flow Points "r'' V"' CV) CI) ' ... : :14: Nozzle P/N 13729 13729 N co co t-- .,...... et CO 0) .T.- 11982 ' 11982 11982 17461 _I et c0 CD c- r-- 14178 11982 J CV 00 0) v- 13729 CO I,- v"" V- et op cp v- F..e-= CO CO (3) C.%1 03 0) N-- 11982 13729 4 — 11982 11983 11983 11983 Z , 0 .1 Z 11982 Z a- ' CD N .2 CO 1.- "I" COCO CO .•-- 'Cr CO CO-- 01 CO 0) e- 2-11983 01 CO 0) .e.• F 01 40 0) V.. 0 = Deep Fat Fryer — without Drip Pan Deep Fat Fryer — with Drip Pan Deep Fat Fryer — with Drip Pan Low Proximity I Range -- Single Burner Range — Two Burner Range — Two Burner I Range- Two Burners w/Back Shelf I Low Back-Shelf/Salamander — BS Manifold I Range — Three Burners I Range — Four Burners ..... I Griddle I Griddle a) 0 0 Upright Broiler I Charbroiler (Lava Rock) Charbroiler (Gas Radiant & Electric Radiant) I Chain Broiler — Closed Top Chain Broiler — Open Top Chain Broiler — Nieco Model 9025 /Catalyst (2) I Natural & Mesquite Charcoal Charbroiler I Mesquite Chips & Chunks Charbroiler Mesquite Log Charbroiler Plenum Single Bank/V-Bank Duct I Circular a g 0 c4 I Circular At go c4 0 c4 Circular CO CO F 2 a. OD CD TF a. - CO F qs. 2 a. co CO CO F 2 a. CO p. toe 2 July 2006" Section 3 Design Page _3 = 22 Amerex KP Wet Chemical System (EX 4658) KP DISTRIBUTION PIPING DESIGN LIMITS FOR ALL CYLINDER SIZES When designing a KP system to protect a kitchen containing a Fryer, Wok or Range, the following MINIMUM TOTAL SYSTEM PIPING must be used in accordance with the chart below: PIPING REQUIREMENTS MINIMUM MINIMUM TOTAL APPLIANCE LINEAR FEET Wok Ranee 6.5 9 7 EQUIVALENT FEET 10 22.1 16.4 MINIMUM FLOW POINTS PER SYSTEM 2 6 4 SUPPLY LINE LIMITATIONS: All pipe and fittings running from the distributor block or the discharge fitting to the first tee. °CYLINDER MAXIMUM LINEAR MAX. QTY. MAX. QTY. MAX. QTY. FLOW POINTS PIPE SIZE FEET OF PIPE TEES ELBOWS BUSHINGS KP275 - 8 3/8 20 1 5 0 KP375 - 11 3/8 OR 1/2 25 1 5 1 KP475 -14 1/2 25 1 5 2 KP600 - 18 1/2 25 1 5 2 2-KP375 - 22 1/2 30 2 7 2 NOTE: 1. Use 3/8" supply line only when all piping is to be 3/8" pipe. 2. The supply line has a maximum vertical rise above the distributor of 10 feet. SUPPLY BRANCH LINE (including last nozzle branch) LIMITATIONS: All pipe and fittings leaving the first splitting tee in the system and ending with the last nozzle in the last branch line. While the last nozzle branch is included in the piping limitations for the supply branch line, the limitation (pipe size and maximum length) for nozzle branch lines apply to this portion of the supply branch line. CYLINDER MAX. FEET OF MAX. MAX. FLOW PIPE STRAIGHT MAX. FEET OF QTY. QTY. POINTS PIPE SIZE PIPE SPLIT TEES ELBOWS MAX. QTY. REDUCING BUSHINGS KP275 - 8 3/8 20 25 7 8 0 KP375 - 11 3/8 OR 1/2 27 30 10 8 2 KP475 - 14 3/8 27 30 12 8 2 KP600 - 18 AS NOTED 35' OF 3/8" OR 1/2" 50' 3/8" PIPE ONLY 14 8 2 2-KP375-22 AS NOTED 40' OF 1/2" 45 OF 1/2" 18 8 0 (*30' OF 3/8") r30' OF 3/8") NOTE: 1. In a single 3.75 Gallon Straight Pipe System, 5' of pipe may be transferred from the supply line to the supply branch line. *2. The use of 3/8" pipe with two manifold KP375s is only permitted when the supply Line length is equal to or less than 20 feet. NOZZLE BRANCH LINE LIMITATIONS: All pipe and fittings leading from the supply branch tee to a system nozzle. CYLINDER TOTAL LINEAR MAX. QTY. MAX. QTY. MAX. QTY. FLOW POINTS PIPE SIZE FEET OF PIPE TEES ELBOWS BUSHINGS KP275 - 8 3/8 32 5 10 0 KP375 - 11 3/8 OR 1/2 32 8 12 11 KP475 - 14 3/8 32 10 15 0 KP600 - 18 3/8 32 11 18 15 2-KP375 - 22 3/8 32 18 18 20 MAX. PER NOZZLE BRANCH 7 3 6 4 GENERAL SYSTEM LIMITATIONS: 1. No %2" pipe nozzle branches shorter than 12" long. 2. Nozzle types may not be mixed on any nozzle branch line and a maximum of 4 flow points. �3. The discharge fitting, distrib and distribution hose are not to be included in any calculations. 4. No mixing of pipe sizes ' allowed wi in pipe categories. Example: if one nozzle branch is to be Y2" pipe then all must be'/2" pipe. '/z' pe for nozzle anch lines is allowed only in an 11 flow point system. 5. - Duct nozzle hos a aximum vertical se above the supply branch line of 4'0". October 2003 •Sec491.1- .: ` Desi .:_ Aniierez kiMet_C em• ' :- Page,36.,:. FRYER PROTECTION (FULL VAT) - TWO FLOW POINT NOZZLE (PIN 13729) MAXIMUM AREA: 19YZ in. (50 cm) x 25-318 in. (65 cm) including drainboard interface area 19% in. (50 cm) x 19 in. (48 cm) not including drainboard interface area The Amerex fryer nozzle (P/N 13729) uses two flow points and will protect a full vat fryer. If the fryer does not include a drainboard, the maximum fryer dimensions for single nozzle coverage are 192x 19W (48 x 50 cm) and the maximum protected area is 2.53 ft2 (2350 cm2). if the fryer does contain a drainboard the maximum fryer dimensions for single nozzle coverage are 25- 3/8" x 19W (65 x 48 cm) and the maximum protected area is 3.44 ft2 (3195 cm2). However, the maximum hazard area must not exceed 19" x 19 %z" (48 x 50 cm). The nozzle must be located along or anywhere within the protected area. Nozzle heights must be within 36 to 48 inches (91.44 — 121.92 cm) above the appliance surface and aimed to the center of the hazard area of the appliance. LOON staszte „ahT„ thadtstable (than the grnrcted+ees) salyikusine AM Po* ICEN1ER of; HAZARD RAM 46' Note: Maximum & minimum heights must be measured vertically from the tip of nozzle to the top of the appliance. WITH ORAINBOARO yaniszmammumem LOW PROXIMITY APPLICATION FRYER PROTECTION (FULL VAT) TWO (2) SINGLE FLOW POINT NOZZLE (PIN 11982) MAXIMUM AREA: 19% in. (50 cm) X 25 318 in. (65 cm) (including 19% in. (50 cm) x 19 in. (48 cm) (not including A pair of Amerex single flow point nozzles (P/N 11982) wi€l protect a full vat fryer. The nozzles must be used in pairs located on the perimeter of the appliance, %i" back from the inside edge of the appliance and within a zone extending 6" in both directions of the center of the hazard. The nozzles are to be located 180° apart (directly across from one another). They are to be aimed at a point 3" below the top of the appliance and directly below the opposing nozzle. if the fryer does not include a drainboard, the maximum fryer dimensions are 19W x 19" (50 x 48 cm) and the maximum protected area is 2.53 ft2 (2530 cm2). If the fryer does contain a drainboard, the maximum fryer dimensions are 25 3/8" x 19 '4" (65 x 50 cm) and the maximum protected area is 3.44 ft2 (3195 cm2). However, the maximum hazard area must not exceed 19 '/_ ` x 19" (50 x 48 cm). The nozzle's height must be within 1 T/z" to 36" (45 - 92 cm) above the appliance surface. drainboard interface area) drainboard interface area) FULL VAT PRYER WITH DRAINBOARD i i December 2008 Section 3 KP Design Page 3 —13 { Amerex Restaurant Fire Suppression System (EX 4658) ' GRIDDLE PROTECTION — SINGLE FLOW POINT NOZZLE (P/N 11982) The Amerex griddle nozzle (P/N 11982) has one flow point and will protect a griddle surface of 36 inches wide (91 cm) x 30 inches deep (76 cm). The nozzle must be located along the perimeter of the appliance and within a vertical height range from 30" to 48" (76 — 122. cm) above the surface of the appliance. The aiming point for the nozzle is the "point of intersection" of a straight line from the nozzle location to the center of the appliance, with an 11" (28 cm) square, generated about the center point of the griddle. 11" square Centered on Griddle Center Note: Maximum & minimum heights must be measured from the tip of nozzle to the surface of the appliance. Perimeter of Griddle Point of intersection AIM POINT Nozzle Location GRIDDLE PROTECTION — MULTIPLE SINGLE FLOW POINT NOZZLES (P/N 11982) Multiple Amerex griddle nozzles (P/N 11982 — one flow point) may be used to protect a griddle surface area greater than 30 inches (76 cm) X 36 inches (91 cm). The griddle must be divided into modules for single nozzle coverage and the nozzles located and aimed for each module as indicated for single nozzle coverage. 11" square centered on griddle center Perimeter of Griddle / Modules Module 2 Module 1 — Note: Maximum & minimum heights must bemeasured from the tip of ;,` nozzle to the surface of the appliance. 48" 40 11" square centered on griddle center a -4B` max. —34` min. 72" max. Nozzle Location Point of Intersection AIM POINT for nozzle protecting this module 11 Sqm* 'Contend on Griddle Module 11" square centered on griddle center October 2003 Section 3 Design Page 3-10 Arnerex KP Wet Chemical System (EX 4658) FOUR (4) BURNER RANGE PROTECTION TWO (2) FLOW POINT NOZZLE (PIN 14178) The Amerex 4 burner range nozzle (P/N 14178) has two (2) Sow points and will protect a range surface area of 24" x 24" (61 x 61 cm). The center to center distance between burners must not exceed 12 inches. The nozzle must be located 18 - 50" (46 - 127 cm) above the range surface and centered between the burners. The nozzle is aimed straight down at the center of the appliance. NOTE: Maximum and minimum heights must be measured from the tip of nozzle to the surface of the appliance. RANGE PROTECTION -MULTIPLE NOZZLES (P/N 14178) For ranges `that have a surface area exceeding the capabilities of a single nozzle, multiple nozzles must be used provided that the surface area of the range is divided into equally sized modules. Each module must be equal to or less than 24" x 24" (61 x 61 cm). NOTE: When using this nozzle to protect a two (2) burner range the aiming point is where an 8.50" radius from the center of each burner crosses one another WOK PROTECTION SINGLE FLOW POINT NOZZLE (PIN 11982) The Amerex appliance plenum nozzle (P/N 11982) has one flow point and will protect a wok with ::dimensions between a minimum diameter of 14" (36 cm) and a maximum diameter of 24" (61 cm) inclusive. The wok must have a height dimension between a minimum of 4" (10 cm) and a maximum of 7" (18 cm) inclusive. The nozzle must be centered over- the center of the wok and located at a height between 40 " (102 cm) and 50" (127 cm) from the bottom of the inside of the wok and aimed at the center of the wok. Mrn. Size Aim Point Max. size ® Without Comments ® As Noted in Red L( Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances, The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: -5-- Lt ^ ( By: Si TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address forshut- down or restoration approval, ';y'MBOL LEG'ENO E Xu-co4c, vtlkc N kb'st0JUOl. ® EX,S-w e, St•t•KE EXtwrItAG- flvc.'T gMbKt vOtoot E)asrt►JG1 mD0als3A41.E PV1.� Th1tQN A a Ew comsstostE inivv-t*okoagLC NES ce\oo n MO4brc S"KRObe ND AA 'l. ‘at, tnoOsSr vAtaw1S'k tOber Q 9AM?EtL t LAy' COMMINDCE corn+ AIM40100 130400 MOPE U 5 P C 'TER @ 14 ?.)s *-T WALL Imo. t3 tko s„ C --,at: 0102 _‘,0 Cd "T1k£ SnfE-t 1�rh 1Nc SvL.i54hao► OF N Eg Without Comments O As Noted in Red 0 Per The Attached Letter '-hese plans have been reviewed by The Tukwila Fire- evention Bureau for conformance with current City ndards, Acceptance is subject to errors and l:3slons which do not authorize violations of adopted ::ndards and ordinances. The responsibility for the °.:,;quacy of design rests totally with the designer. .,Aitions, deletions or revisions to these drawings after is date will Void this acceptance and will require a resubmittal of rev;sed drawings for subsequent approval. Final acceptance Is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: 7�� �I By: NOTICE -A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. miumwmprepq 5 L 4 31 J t 5- 5 enamo Irinimor otli oiltiur,WiHMptuVINI.Ntiq11NRIIMPIVhUMIIIMIT1' 623581 ,1".‘ - PROm LIVE 759-V -- -N *ROP LINE 313 -4 STING ADINO COCK c 4, i LINE_`-'l,a' I . 1 O 1 r Ili l 11 NO C4144OE 70 PARK.NG LANDSCAPE LOT COVERAsE OR EXTERIOR SHEL _ OF THE 1141N $TR.' CTU 1 i PROJECT DATA CF — r 2! t Q/ PP.ca 1e7 tl�\ GJGJ m/ T TENANT IMEROVE IENr OF EASTERN TENANT SPACE OF EXISTING BUILONG FOR USE A$ RETAIL TAX RARCEL NUMBER 192304-90n - ------- ---_----_---_-- SCUM 1445T&T1ET r J Fig. 58 - Threaded Side Beam Bracket Size Range — 3/8" rod, pipe sizes 1/2" thru 4" Material — Carbon Steel Function — Practical and economical bracket used to support piping from wood, concrete or steel beams Features — Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment Center mounting hole will accept 3/8" and 1/2" fastener bolts. Per NFPA 13. 1/2" tnru 21" pipe requires 3/8" fastener, 21" thru 4" pipe requires 1/2" fastener.' Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4" pipe *Note — Additionally UL has listed the Fig. 58 with fasteners as shown in table below. Finish — Plain Note — Available in Electro -Galvanized finish_ Order By — Figure number and finish UL Listed Fastener Table Pipe Size Qty. Fastener Type Material 2 2 1116 x 2 Dnve Screws 2 1 3/8 Lag Bolt 21/2 - 4 1 1/2 Lag Bolt 31h 2 1/4 x 11h Lag Bolt 4 2 1/4 x 2 Lag Bolts' 4 2 1/4 x 1 tek screws 4 2 1/'4 x 1 tek screws Wood Wood Wood Wood Wood 14 gauge 16 gauge ' No pre -drilling required Dimensions • Weights Pape Size 1/2 thru 4 Rod Size 3/8 A 23 Max. Rec. Approx. B B Load Lbs* WtJ100 11 17 300 14 • With safety factor of 5 CC)US LISTED 2-14x2Lag ioil5 ,No Pre-un9,ng1 Op — to 4 ,n -ti P1;18 Pe- NcPA 1 - La_ OGlt -- Up To 4 Irch Pipe 2 _17'6x2 t,rl,c Screws ,2 Thr.) 2 Inch Dile f.. (" 1` r '42 syr, 5:-e S ,r -to •'I'1 CGa jtE� LJs. Ta 4 "•C1' P'1 -e- 5911 & Hex. Not Up To 4 Inch -, - Pipe • .,,,,*--t",,- ;ti -5 3033 -Bainbridge Island Den Bremerton Port Orchard 4'Jhite Center 11g! rn:a uest4- laktraHarbor 1 5ml EXIT / • i j EXISTING - ' ► REv1t.'CX ri7 ' ,. -, " - , 523 — (`SEATTLEsilos fel' l �99t�.t KiTKiantl Redmorid - - -, -- dCarnatic n LIS "'4F,311 City 1; `it'�ti, - Bryn Mawr - 0 +L:.cam• =r_ j'5"-""--1,,)LRenton Ttlkwii4 •,. �l 4Seata(c Jf 5 115Kent . -�� ` a*` F e d e ra 1 Way - �;. @2011 MapOuest - Portions ©2011 HAV/E0, tntermap pie Valley _- (18�= ELECTRICAL CLOSET /-, HOT UJATER - EXISTING . RESTROOM - ' /- IMPROVEMENTS IN SHADED - - AREA ARE EXISTING EXCEPT TILE FLOC,R AT HALLWAY/ - LEGEND / LINE EXIT / f 7.71 --As No!ed in Re> s tX Per The Ar r .r Lett& These plans have beers re•Ylewed by The Tukwila Fre Prevention Bureau for cc-forman,:e with current City standards. Acceptance is s_b2ect r.o errors and - omissions which do r(t = " �..=e vio13:1ri'S Q= adopted standards and ordinances Toe res3....;ns c far the` a laquacy of design rests :oza, y ,;.ii;+ zes gner. Additions, delet or trr-ese. dr wi;'gs after tells date will void c^,s .ceecka:'L:-2 a -a i + recu'ir e a resubrriittai of revised crawir1;! f >• __1_9_:;:tent approval. Final acceptance is s.Jr_.rct to ficic zest and Inspection by The Tukwila Fire PI eve' `t;o,i , Bureau. ts- (( By: FREEZER 204 U,ALKIN COL 203 1-C: 1. - 1 I .40(,-z 8 60-‘,/-1---‘" 0 O O O N •_ EMI to TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give ttli$ FiKe Permit No.and exact address for shut- down or restoration approval. t i• i • EXISTING , HALLWAY OF FULL PARTITIONS 2 - • P'RUJ L.0 l DA l A SCOPE OF WORK 1 TENANT IMPROVEMENT OF EASTERN TENANT SPACE i 10F EXISTING. BUILDING FOR USE AS RETAIL L , 'Ax PARCEL NUMBER 152304-5011 — - 51-At5DRE55 - - 14221 TUKWILA INTERNATIONAL BLVD, SUITE 0 TUCWILA WASHINGTON 98188 CILNERTENANT_ - _ _-- _- -- , - - JJBA CENTER LLC _ 3920 SOUTH 146T14 STREET SUITE Ei TUKUILA WASL,INGTON 98168' -- - LANDLORD/PARCEL OWNER_ '— -- y SEG 5674 LLC - 010 FIRST WESTERN PROPERTIES INC_ 520 KIRKLAND WAY SUITE 100 KIRKLAND, WAS'-,INGTON 98033 LEGA_ DESCRIPTION 5EG 289 FT E OF SW COR O= 65 1/4 OF 51.1) 1/4 TH N2-1930 GT TO TPO5 TI-, CONT N 15010 ^T TH 5 329 FT M/L TO W_Y LN OF ST HUN • I TH SLY ALG 50 ILLY LN TO A PT UA•IICH SEARS 5 86-33-03 5 294.65 FT FR TPO13 TH N 86-33-03 LU 2941,5 FT TO TPO5 ZONING- NCC TYPE OF CONS -RUCTION 215 (MASONRY) TYPE OF FIRE PROTECTION. FIRE SPRINKLERS 5J1LING ARE, DRUG STORE 11 LAUNDRY - iI 1066 SF (15 OCCUPANCY) 3114 SF (3 OCCUPANCY) F,0.40 5 (1-1/"/-1 ?1rP1,p l.u/'YJ 2,4 <p Gr. (61 OCCLr'As CY) I�TA,L _• '/ .3,562 5.F (I'1OCCUPANCY) AR~A Or TENANT SPACE fT14I5 AP) • _ 2,031 SF, (5 OCCUPANC") TOTA_ BUILDING- AREA" - - 32,853 SF , YEAR BUILT / ' - 1918 - T1 -1S PE41,:-AIFI ICAT1 l JUBA CE TR SE=A' PI -,ASE I N"I @O ,YEMENIS, IS PHA 05 Y 11.11-ROVM'CNTo Or T (1146 FILED FOR TENANT SERV. DINING FAC y4 AREA REA OCCJPA CY T"PE OCCUPA 1LOAD PROVIDED REQUIRED PARKI PARKi iFOR1UL 51-10PT'ING CENTER (32,933 (4 STALLS PER 1000) = 132 STALLS c 5 109, 5F 940 SF 2,031 6F. 218 EXISTING STALLS FORMU_ '2 R=TAIL SARTELLS 15,066 SF LIQUOR STORE 5040 SF JU15A (PHASE 1) 3,562 SF (24,268 - )(4 STALLS PER 1,000) = 100 STALLS ORAE 2,640 5F (2240 '_. (I STALL PER 2,000) LAUNDR 2 640 5F (3114 5-) (` STALL PER 300) _ 2 STALLS 13 STALLS CAFE ( I -/IS APPLICATION) 2031 SF (2,031 (1 STALL PER 100) = 21 STALLS APPL IC INTERNA INTERNA INTERNA UNi-OR'1 136 STALLS ELE CODES - CURRENT EDITIONS OF ,ONAL 6U'LDING CODE, WAC 51-50 ZONAL MECHANICAL CODE (IMC) ZONAL FI' CODE WAC 51-34 F� UMB NG CODE (UPC) It SPRINKLER RISER RDO AL 3/S' 1 1 CEILING PLAN 01 YAMINVIID A HANGER LEGEND "U"- HOOK M MACHINE THREADED ROD COACH SCREW ROD N P POWDER DRIVEN STUD UNIVERSAL BEAM CLAMP R EXPAIsTSION BOLT EYE ROD FITTING LEGEND SYM MANUFACTURER SN SHAPED NIPPLE SPRINKLERS USED TYPE MODEL _Astm CANOPY FINISH ORIFICE THREAD SIZE SI E TEMP QTY 140 1S5— DATE BY REVISIONS COMMENTS APPROVALS REQUIRED CEILING FLANGE SIDE BEAM BRACKET LL SHORT CLIP "L"- ROD 2 WAY EARTHQUAKE BRACE TOTAL THIS SHEET GENERAL NOTE: In localities subject to freezing condi- tions it is the owner's responsibility to pro- vide teat throughout areal protected by a wet -pipe sprinkler system and in end° sures-for dry pipe, deluge and other types of sprinkler valVes controlling water supplies to sprinkler systems CONTRACT WITH C— rCS CONTACT PHONE NO JOB SITE SUPERVISOR JOB SITE PHONE Owner Licensed I Bonded First Defense Fire Protection "Sprinklers Beat Firemen To The Blaze" QUALM' LUN - Office: (360) 794-9479 / Fax: (360) 794-941) millutkicensefire0.hotmail corn_ APPROVED FOR FABRICATION BY izx iu NORTH F'‘rarcirdiSq6,11 1 PROJECT TITLE PAID JUN —8 2011 TUKWILi FIRE CEric SHEET OF JOB NUMBER 440114.4 .4444,44-7.42 tqca I Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY -B — 2.8, 5.6, and 8.0 K -factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The Series TY -B, 2.8, 5.6, and 8.0 K -factor, Upright and Pendent Sprin- klers described in this data sheet are standard response - standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TY -B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- IMPORTANT Always refer to Technical Data Sheet TFP700 for the 'INSTALLER WARNING' that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY -B Pendent Sprinkler can be obtained by utilizing the Series TY -B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TY -B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1151 - Upright 2.8K, 1/2"NPT TY1251 - Pendent 2.8K, 1/2"NPT TY3151 - Upright 5.6K, 1/2"NPT TY3251 - Pendent 5.6K, 1/2"NPT TY4151 - Upright 8.0K, 3/4"NPT TY4251 - Pendent 8.0K, 3/4"NPT TY4851 - Upright 8.0K, 1/2"NPT TY4951 - Pendent 8.0K, 1/2"NPT DECEMBER, 2007 TFP751 Page 2 of 8 TFP151 ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING 1/2" ** NOMINAL SURFACE NPT MAKE -IN 2-1/4" (57,2 mm) SSU* DEFLECTOR 1-9/16" (39,7 mm) WRENCH FLATS SSP* DEFLECTOR PENDENT UPRIGHT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression 7 - Bushing Screw CROSS SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS 2.8 K -FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) 7/16" (11,1 mm) 1/2" ** NOMINAL NPT MAKE -IN STYLE 10 RECESSED ESCUTCHEON SSU* DEFLECTOR iir1111r.V. WRENCH FLATSI 2-7/8"(73,0 mm) DIA. SSP DEFLECTOR* PENDENT 7/16" (11,1 mm) NOMINAL MAKE -IN 2-3/16" (55,6 mm) 1/2" NPT** RECESSED PENDENT UPRIGHT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression Screw CROSS SECTION * * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K -FACTOR, 1/2 INCH NPT TFP151 Page 3 of 8 ESCUTCHEON PLATE SEATING SURFACE 2-5/16" 1/2" (12,7 mm) 3/4"** NOMINAL NPT MAKE -IN STYLE 40 RECESSED ESCUTCHEON SSU* DEFLECTOR (58,7 mm) 1-9/16" (39,7 mm) SSP DEFLECTOR* 1 - Frame 2 - Button PENDENT 11L NOMMENEW _1I WRENCH FLATS 2-7/8" (73,0 mm) DIA. RECESSED PENDENT 3 - Sealing 4 - Bulb Assembly 5 - Compression Screw 6- Deflector 1/2" (12,7 mm) NOMINAL MAKE -IN 2-1/4" (57,2 mm) 3/4" NPT** UPRIGHT CROSS SECTION * * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS 8.0 K -FACTOR, 3/4 INCH NPT 1 -Frame 2 -Button ESCUTCHEON PLATE SEATING SURFACE 7/16" (11,1 mm) NOMINAL MAKE -IN SSU* DEFLECTOR SSP* DEFLECTOR PENDENT UPRIGHT CROSS SECTION 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K -FACTOR, 1/2 INCH NPT Page 4 of 8 TFP151 NOTES 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** 150'F/66°C Maximum Ceiling Temperature. *** Frame and deflector only. Listings and approvals apply to color (Special Order). TABLE A, LABORATORY LISTINGS AND APPROVALS SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE"" LEAD WAX WAX OVER LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135°F/57°C Orange PENDENT 155°F/68°C Red 2.8 (TY1251) 1, 2, 3 N/A 1/2" and 175°F779°C YeUow NPT UPRIGHT 200°F/93°C Green (TY1151) 286°F/141 °C Blue 360°F/182°C Mauve 1, 2 135°F/57°C Orange PENDENT 155°F/68°C Red (TY3251) and 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 5 175°F/79°C Yellow UPRIGHT 200"F/93°C Green 5.6 (TY3151) 286F/141°C Blue 1**,2**, 3**, 5** 1" 2**3**, 5** 1/2" 360"F1182°C Mauve N/A NPT 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1, 2, 3, 4, 5 N/A 175°F179°C YeNow (TY3251)* Figure 4 200°F/93°C Green 286°F/141°C Blue 1, 2 135°F/57°C Orange PENDENT 155°F/68°C Red (TY4251) 1, 2, 5 1, 2, 3, 5 1, 2, 5 and 175°F/79°C Yellow 1, 2, 3, 4, 5, 6, 7 8.0 UPRIGHT 200°F/93°C Green 3/4" (TY4151) 286°F/141 °C Blue 1 ** 2** 3**, 5** 1 ** 2** 5** NPT 360°F/182°C Mauve N/A 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1, 2, 3, 4, 5 N/A 175°F/79°C Yellow (TY4251)* Figure 5 200°F/93°C Green 286°F/141°C Blue 1, 2 135°F/57°C Orange PENDENT 155°F/68°C Red 8.0 (TY4951) 1/2" and 175F/79°C Yellow 1, 2, 3, 4, 5, 6 N/A NPT UPRIGHT 200F/93°C Green (TY4851) 286°F/141°C Blue 360°F/182°C Mauve NOTES 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** 150'F/66°C Maximum Ceiling Temperature. *** Frame and deflector only. Listings and approvals apply to color (Special Order). TABLE A, LABORATORY LISTINGS AND APPROVALS `TFP151 Page 5 of 8 NOTE: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C -UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Technical Data Approvals UL and C -UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete ap- proval information including corrosion resistant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/barli2) K = 5.6 GPM/psi112 (80,6 LPM/barla) K = 8.0 GPM/psiv2 (115,2 LPM/bar1/2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table A. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame Bronze Button Brass/Copper Sealing Assembly Beryllium Nickel w/Teflont Bulb Glass Compression Screw Bronze Deflector Copper Bushing (K=2.8) Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. , Design Criteria The Series TY -B Pendent and Upright Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. t DuPont Registered Trademark SPRINKLER FINISH K TYPE NATURAL BRASS CHROME PLATED WHITE POLYESTER LEAD COATED WAX COATED WAX OVER LEAD COATED 2.8 1/2" NPT PENDENT (TY1251) and UPRIGHT (TY1151) 175 PSI (12,1 BAR) N/A 5.6 1/2" NPT PENDENT (TY3251) and UPRIGHT (TY3151) 250 PSI (17,2 BAR) OR 175 PSI (12,1 BAR) (SEE NOTE 1) 175 PSI (12,1 BAR) RECESSED PENDENT (TY3251) N/A 8.0 3/4" NPT PENDENT (TY4251) and UPRIGHT (TY4151) 175 PSI (12,1 BAR) RECESSED PENDENT (TY4251) 175 PSI (12,1 BAR) N/A 8.0 1/2" NPT PENDENT (TY4951) and UPRIGHT (TY4851) 175 PSI (12,1 BAR) NOTE: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C -UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Technical Data Approvals UL and C -UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete ap- proval information including corrosion resistant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/barli2) K = 5.6 GPM/psi112 (80,6 LPM/barla) K = 8.0 GPM/psiv2 (115,2 LPM/bar1/2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table A. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame Bronze Button Brass/Copper Sealing Assembly Beryllium Nickel w/Teflont Bulb Glass Compression Screw Bronze Deflector Copper Bushing (K=2.8) Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. , Design Criteria The Series TY -B Pendent and Upright Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. t DuPont Registered Trademark Page 6 of 8 5/811 /4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) 3/4" (19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE Z. 1% w%1T q41 Pr— 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES TY -B 1-1/4" (31,8 mm) 3/4" (19,1 mm) FIGURE 5 SERIES TY -B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K -FACTOR, 1/2 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) 3/4" (19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" �.rII (3,2 mm) MOUNTING SURFACE CLOSURE SERIES TY -B 1-5/16" (33,3 mm) 13/16" (20,6 mm) FIGURE 6 SERIES TY -B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K -FACTOR, 3/4 INCH NPT TFP151 WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 7 W -TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W -TYPE 7 RECESSED SPRINKLER WRENCH installation The Series TY -B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135"F/57°C to 3/32 inch (2,4 mm) for the 360°F/182°C temperature ratings. A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A 3/4 inch NPT sprinkler joint should be obtained with a mini- mum to maximum torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over -tightening the 'TFP151 Page 7 of 8 sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY -B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type 6 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures 1, 2, 3, and 4 the W -Type 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. The Series TY -B Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W -Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, the W -Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the Series TY -B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TY -B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non -operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in ac- cordance with local requirements and/or national codes. • Page 8 of 8 P/N 57 -XXX -X -XXX I MODEUSIN 530 2.8K UPRIGHT (1/2"NPT) TY1151 531 2.8K PENDENT (1/2"NPT) TY1251 570 5.6K UPRIGHT (1/2"NPT) TY3151 571 5.6K PENDENT (1/2"NPT) TY3251 590 8.0K UPRIGHT (3/4"NPT) TY4151 591 8.0K PENDENT (3/4"NPT) TY4251 560 8.0K UPRIGHT (1/2"NPT) TY4851 561 8.0K PENDENT (1/2"NPT) TY4951 SPRINKLER NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010) * 9 CHROME PLATED 7 LEAD COATED 6 WAX COATED 286°F/141°C MAX. 8 WAX OVER LEAD 286°F/141°C MAX. TABLE C PART NUMBER SELECTION SERIES TV -B PENDENT AND UPRIGHT SPRINKLERS TFP151 TEMPERATURE RATING 135 135°F/57°C 155 155°F/68°C 175 175°F/79°C 200 200°F/93°C 286 286°F/141°C 360 360°F/182°C " Eastern Hemisphere sales only. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied. including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Stand- ard Response, (specify K -factor), (specify temperature rating), Series TY -B (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify 10 or 40 ) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W -Type 7 Sprinkler Wrench, P/N 56-850-4-001. © 2007 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqca I Fire &Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series DS -1 — 5.6 K -factor Dry Type Sprinklers Standard Response, Standard Coverage General Description The Tyco® Series DS -1, 5.6 K -factor, Standard Response, Standard Cover- age, Dry Type Sprinklers are decorative 5 mm glass bulb automatic sprinklers designed for the following typical uses: • where pendent sprinklers are re- quired on dry pipe systems that are exposed to freezing temperatures (e.g. sprinkler drops from unheated portions of buildings) • where sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g. sprinkler drops from wet sys- tems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping exten- sions through a wall to protect an unheated area of a building) • where sprinklers are used on sys- tems that are seasonably drained to avoid freezing (e.g. vacation re- sort areas) WARNINGS The Series DS -1 Dry Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. The Series DS -1 Dry Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler identification Numbers TY3255 - (Pendent) TY3155 - (Upright) TY3355 - (Horizontal Sidewall) Technical Data Approvals UL and C -UL Listed. FM and NYC Approved. (Refer to Table A) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connection 1 inch NPT (Standard Order) ISO 7-R1 Discharge Coefficient K = 5.6 GPM/psi12 (80,6 LPM/bar12) Temperature Ratings Refer to Table A Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated or Chrome Plated, Brass Plated Physical Characteristics Inlet Copper Plug Copper Yoke Stainless Steel Casing .... Galvanized Carbon Steel Insert Bronze Bulb Seat Stainless Steel Bulb Glass Compression Screw Bronze Deflector Bronze Frame Bronze Guide Tube Stainless Steel Water Tube Stainless Steel Spring Stainless Steel Sealing Assembly Beryllium Nickel w/Teflon* Escutcheon Carbon Steel *Registered Trademark of DuPont Patents U.S.A. Patent No. 5,188,185 JANUARY, 2008 TFP500 Page 2 of 8 TFP500 Notes: 1. Listed by Underwriters Laboratories, Inc (Maximum order length of 48 inches). 2. Listed by Underwriters Laboratories for use in Canada (Maximum order length of 48 inches). 3. Approved by Factory Mutual Research Corporation (Maximum order length of 48 inches) 4. Approved by the City of New York under MEA 352-01-E. * Light and Ordinary Hazard Occupancies Only. ** Light Hazard Occupancies Only. N/A - Not Available. TABLE A SERIES DS -1, STANDARD RESPONSE - STANDARD COVERAGE, DRY TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH GASKETED SPRING PLATE SEAL SPRING WATER TUBE GUIDE TUBE FRAME VENT HOLE DEFLECTOR INLET YOKE CASING INSERT BULB SEAT 5 mm BULB COMPRESSION SCREW FIGURE 1 SERIES DS -1, STANDARD RESPONSE DRY TYPE SPRINKLERS ASSEMBLY WRENCH FLAT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCH FLATS FIGURE 2 W -TYPE 7 SPRINKLER WRENCH SPRINKLER FINISH TY3255 Pendent TY3255 Pendent TY3355 Hor. Sidewall w/ Standard w/ Std. Escutcheon with top of Recessed Escutcheon (Ref. Fig. 5) Deflector -to -Ceiling (Ref. Fig. 3) w/ Deep Escutcheon distance of w/ Wide Flange (Ref. Fig. 6) 4 to 12 inches Recessed Escutcheon w/o Escutcheon (100 to 300 mm) (Ref. Fig. 4) (Ref. Fig. 7) w/ Std. Escutcheon (Ref. Fig. 9) TY3155 Upright w/ Deep Escutcheon Ref. Fig. 10) w/o Escutcheon w/o Escutcheon (Ref. Fig. 8) Ref. Fig. 11) Temperature Bulb Color Natural Chrome White Natural Chrome White Natural Chrome White Rating Code Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F/57°C Orange 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1*, 2*, 3**, 4 1*, 2*, 4 155°F/68°C Red 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1*, 2*, 3**, 4 1*, 2*, 4 175°F/79°C Yellow 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1*, 2*, 3**, 4 1*, 2*, 4 200°F/93°C Green 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1*, 2*, 3**, 4 1*, 2*, 4 286°F/141°C Blue N/A 1, 2, 3, 4 1, 2, 4 1*, 2*, 3*", 4 1*, 2*, 4 360°F/182°C Mauve N/A 1, 2, 3, 4 1, 2, 4 1*, 2*, 4 1*, 2*, 4 Notes: 1. Listed by Underwriters Laboratories, Inc (Maximum order length of 48 inches). 2. Listed by Underwriters Laboratories for use in Canada (Maximum order length of 48 inches). 3. Approved by Factory Mutual Research Corporation (Maximum order length of 48 inches) 4. Approved by the City of New York under MEA 352-01-E. * Light and Ordinary Hazard Occupancies Only. ** Light Hazard Occupancies Only. N/A - Not Available. TABLE A SERIES DS -1, STANDARD RESPONSE - STANDARD COVERAGE, DRY TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH GASKETED SPRING PLATE SEAL SPRING WATER TUBE GUIDE TUBE FRAME VENT HOLE DEFLECTOR INLET YOKE CASING INSERT BULB SEAT 5 mm BULB COMPRESSION SCREW FIGURE 1 SERIES DS -1, STANDARD RESPONSE DRY TYPE SPRINKLERS ASSEMBLY WRENCH FLAT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCH FLATS FIGURE 2 W -TYPE 7 SPRINKLER WRENCH TFP500 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) r--1 FACE OF SPRINKLER FITTING } \ ORDER LENGTHS: 3-1/2'to 48' (88,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF CEIUNG 2-1/4° DIA. (57,2 mm) 1-3/8' ± 1/8" (34,9 ± 3,2 mm) 2-7/8" DIA. (73,0 mm) FIGURE 3 TY3255 PENDENT w/ STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF ;. SPRINKLER L FITTING ORDER LENGTHS: 1/2° to 46" (12,7 to 1168,4 mm) IN 1/4' (6,4 mm) INCREMENTS 3-1/2' DIA. (88,9 mm) 2-1/2" DIA. (63,5 mm) • i FACE OF CEILING 4-1/4" ± 1/8' (108,0 ± 3,2 mm) � V FIGURE 6 TY3255 PENDENT w/ DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) r--� ;i FACE OF SPRINKLER FITTING \ ORDER LENGTHS: 3-1/2" to 48' (88,9 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS FACE OF CEILING 3' DIA. (76,2 mm) 1-3/8° ± 1/8' (34,9 t 3,2 mm) 3-5/8° DIA. (92,1 mm) FIGURE 4 TY3255 PENDENT w/ WIDE FLANGE RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER L:1 FITTING L ORDER LENGTHS: 5" to 48' (127,0 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS MINIMUM 1-3/4' (44,5 mm) DEFLECTOR TO CEIUNG FIGURE 7 TY3255 PENDENT w/o ESCUTCHEON Page 3 of 8 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) i I, FACE OF !_l SPRINKLER L__I; FITTING L ` \ - ORDER LENGTHS: 2-1/2' to 48" (63,5 to 1219,2 mm) IN 1/4"(6,4 mm) INCREMENTS FACE OF CEILING 1-3/4' DIA. (44,5 mm) I Ei 2-3/16 ± 1/8" (55,6 t 3,2 mm) 3" DIA. (76,2 mm) FIGURE 5 TY3255 PENDENT w/ STANDARD ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING .i Jr SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 8 TY3155 UPRIGHT w/o ESCUTCHEON Page 4 of 8 TFP500 ORDER LENGTHS: 2-1/2' to 48' (63,5 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF FACE OF — SPRINKLER MOUNTING — FITTING SURFACE 1-3/4" DIA. (44,5 mm) 4' ± 1/8' (101,6 t 3,2 mm) LT\SPRINKLER FITTING ' (REFER TO DESIGN CRITERIA SECTION) CENTERLINE OF WATERWAY f 3' DIA. (76,2 mm) 5/16' (7,9 mm) FIGURE 9 TY3355 HORIZONTAL SIDEWALL w/ STANDARD ESCUTCHEON ORDER LENGTHS: 1/2" to 45-3/4" (12,7 to 1162,1 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING FACE OF MOUNTING SURFACE 4-13/16" t 1/8" (122,2 t 3,2 mm) r-' SPRINKLER FITTING ' (REFER TO DESIGN CRITERIA SECTION) CENTERLINE 5/16" OF WATERWAY (7,9 mm) FIGURE 10 TY3355 HORIZONTAL SIDEWALL w/ DEEP ESCUTCHEON ORDER LENGTHS: 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING T\SPRINKLER FITTING `--^-- ' (REFER TO DESIGN CRITERIA SECTION) MINIMUM 2-1/4" (57,2 mm) DEFLECTOR TO MOUNTING SURFACE / 3.5° 5/16" (7,9 mm) CENTERLINE OF WATERWAY FIGURE 11 TY3355 HORIZONTAL SIDEWALL w/o ESCUTCHEON Operation When the Series DS -1 is in service, water is prevented from entering the assembly by the Plug & Belleville Seal- ing Assembly (Ref. Figure 1) in the Inlet of the Sprinkler. The glass Bulb con- tains a fluid that expands when ex- posed to heat. When the rated tem- perature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to ex- pand and push the Water Tube as well as the Guide Tube outward. This ac- tion simultaneously pulls inward on the Yoke, withdrawing the Plug & Belleville Seal from the Inlet allowing the sprin- kler to activate and flow water. Design Criteria The Tyco® Series DS -1 Sprinklers are intended for use in fire sprinkler sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The 1 inch NPT Series DS -1 Sprin- klers are to be installed in the 1 inch NPT outlet or run of malleable or duc- tile iron threaded tee fittings that meet the dimensional requirements of ANSI B16.3 (Class 150) or cast iron threaded tee fittings that meet the dimension- al requirements of ANSI B16.4 (Class 125). The Series DS -1 Sprinklers may also be installed in the 1 inch NPT out- let of a Grinnell Figure 730 Mechani- cal Tee; however, the use of the Figure 730 for this arrangement is limited to wet pipe systems. Typically, the end sprinkler fitting on a branch line is plugged as shown in Figures 3 through 11. The DS -1 Sprin- klers cannot be installed into an elbow fitting. For wet pipe systems, the sprinkler drop may be installed as shown in Fig- ure 12. The configuration in Figure 12 may only be used where the sprinkler fitting and water filled pipe above the sprinkler fitting is not subject to freez- ing and where the length of the DS -1 Sprinkler has the minimum exposure length per Figure 14. For wet pipe systems, the DS -1 Sprin- klers may also be installed in the fol- lowing Tyco® CPVC fittings: (P/N 80145) 1" x 1" NPT Female Adapter or (P/N 80249) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee. For dry pipe systems, only use the side outlet of maximum 2-1/2 inch size TFP500 Page 5 of 8 reducing tee's when locating the DS - 1 Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 13 to assure complete drainage of water from above the DS -1 Sprinklers and the branch line. NOTE Do not install the Series DS -1 into any other type fitting without first consult- ing the Technical Services Depart- ment. Failure to use the appropriate fitting may result in: failure of the sprin- kler to properly operate due to forma- tion of ice over the inlet Plug or bind- ing of the inlet Plug; or, insufficient engagement of the inlet pipe threads with consequent leakage. Branch, cross, and feedmain piping connected to Dry Sprinklers and sub- ject to freezing temperatures must be pitched for drainage in accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems. When Dry Sprinklers are to be used in wet pipe sprinkler systems protect- ing areas subject to freezing tempera- tures (e.g., sprinkler drops into freez- ers), consideration must be given to the appropriate length of the sprinkler that will prevent freezing of the water in the connecting pipes due to conduc- tion. When the temperature surround- ing the wet pipe sprinkler system is maintained at a minimum temperature of 40°F/4°C, the following are the mini- mum recommended lengths between the face of the sprinkler fitting and the outside surface of the protected area (i.e., length exposed to minimum am- bient of 40°F/4°C — Ref. Figure 14): • 12 inches (300 mm) when the tem- perature within the protected area is -20°F/ -29°C • 18 inches (450 mm) when the tem- perature within the protected area is -40°F/ -40°C • 24 inches (600 mm) when the tem- perature within the protected area is -60°F/ -51°C For protected area temperatures be- tween those given above, the minimum recommended length from the face of the fitting to the outside of the protect- ed area may be determined by interpo- lating between the indicated values. The 2007 edition of NFPA 13, Sec- tion 8.4.10.2 requires that dry sprin- klers connected to wet pipe sprinkler systems protecting insulated freezer structures have the clearance space around the sprinkler barrel be sealed. The use of the Model DSB-2 Dry Sprinkler Boot described in Technical Data Sheet TFP591, and illustrated in Figures 15 and 16, will meet the intent of NFPA 13. TO WET SYSTEM HEATED AREA DSB-2 INTENDED FOR FREEZER STRUCTURES �I. 1 rdoirep SIDE OUTLET PLUGGED 1 INCH NPT TEE (SEE DESIGN CRITERIA SECTION) FIGURE 12, SPRINKLER FITTING IN HEATED AREA TO DRY SYSTEM AREA SUBJECT TO FREEZING id F./ raj RUN OUTLET PLUGGED 1 INCH NPT TEE (SEE DESIGN CRITERIA SECTION) DSB-2 INTENDED FOR FREEZER STRUCTURES FIGURE 13, SPRINKLER FITTING IN UNHEATED AREA FACE OF SPRINKLER FITTING HEATED AREA DSB-2 INTENDED FOR FREEZER STRUCTURES EXPOSURE LENGTH (SEE DESIGN CRITERIA SECTION) FIGURE 14, EXPOSURE LENGTH STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) DSB-2 BOOT ADHESIVE 1-3/4° DIA. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS -1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS -1 DRY SPRINKLER 1-3/4' DIA. (44,5 mm) CLEARANCE HOLE ADHESIVE DSB-2 BOOT INSULATED FREEZER STRUCTURE STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) DS -1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 16 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS -1 DRY SPRINKLER Page 6 of 8 TFP5OO Installation The Series DS -1 Dry Type Sprinklers must be installed in accordance with the following instructions: NOTES The Series DS -1 must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C rating to 1/8 inch (3,2 mm) for the 360°F/182°C rating. A 1 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 20 to 30 ft. lbs. (26,8 to 40,2 Nm). Higher levels of torque may dis- tort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over -tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. Pendent sprinklers must be installed only in the pendent position, and upright sprinklers must be in- stalled only in the upright position. The deflector of a pendent or upright sprin- kler is to be parallel to the ceiling. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpen- dicular to the back wall and parallel to the ceiling. The word "TOP" on the De- flector is to face towards the ceiling. Step 2. With pipe thread sealant ap- plied to the inlet threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler by wrenching on the Casing with a pipe wrench whenever the casing is readily accessible. Otherwise, use a W -Type 7 Sprinkler Wrench (Ref. Figure 2). The wrench recess of the W -Type 7 is to be applied to the sprinkler wrench flats (Ref. Figure 2). Step 4. After the ceiling/wall has been installed/finished, slide on the outer - piece of the Escutcheon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. In the case of the outer piece of the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling), and then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The Tyco® Series DS -1 Dry Type Sprin- klers must be maintained and ser- viced in accordance with the following instructions: NOTES Absence of the outer piece of an es- cutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tems must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evi- dence of leakage from the Vent Hole is an indication that there may be weep- age past the Inlet seal and that the sprinkler needs to be removed for de- termining the cause of leakage (e.g. an improper installation or an ice plug). The fire protection system control valve must be closed and the system drained before removing the sprinkler. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be com- pletely cleaned by wiping the sprin- kler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. The installing contrac- tor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP500 Page 7 of 8 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied. including warranties of merchantability and fitness for a particularpuroose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Dry Sprinklers: Contact your local distributor for availability, and please specify the following: 1. Sprinkler. • Model/SIN. • Standard Response, Standard Coverage, Dry Type Sprinkler • Deflector Style. • 5.6 K -factor. • Order Length. Dry Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 11, as applicable. After the mea- surement is taken, round it to the nearest 1/4 inch increment. • Inlet Connection (1 Inch NPT or ISO 7-R1) • Temperature Rating. • Sprinkler Finish. • Escutcheon Style and Finish, as applicable. • Part Number from Table B. (Part numbers are for 1 inch NPT stan- dard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description.) 2. W -Type 7 Sprinkler Wrench. Refer to the Price List for complete listing of Part Numbers. Model DSB-2: Specify: Model DSB-2 Dry Sprinkler Boot*, P/N 63-000-0-002. * Includes one Boot, two Strap Ties, and 1/3 oz. of Adhesive (quantity of adhesive is sufficient for installing one Boot) Page 8 of 8 TFP500 P/N 60 - XXX - X - XXX MODEL/SIN 96 Pendent w/ Standard Escutcheon (1" NPT) TY3255 (Fig. 5) 93 Pendent w/ Deep Escutcheon (1" NPT) TY3255 (Fig. 6) 97 Pendent w/ Std. Recessed Escutcheon (1" NPT) TY3255 (Fig. 3) 92 Pendent w/o Escutcheon (1" NPT) TY3255 (Fig. 7) 94 Sidewall w/ Standard Escutcheon (1" NPT) TY3355 (Fig. 9) 53 Sidewall w/ Deep Escutcheon (1" NPT) TY3355 (Fig. 10) 54 Sidewall w/o Escutcheon (1" NPT) TY3355 (Fig. 11) 98 Upright w/o Escutcheon (1" NPT) TY3155 (Fig. 8) SPRINKLER FINISH ESCUTCHEON FINISH (2) 1 NATURAL BRASS WHITE 4 WHITE POLYESTER WHITE 9 CHROME PLATED CHROME 0 CHROME PLATED WHITE 3 WHITE (RAL9010)* WHITE (RAL9010)* 2 NATURAL BRASS BRASS PLATED TEMPERATURE RATING (3) 135F/57C 155F/68C 2 175F/79C 3 200F/93C 4 286F/141C 360F/182C NOTES ORDER LENGTH (1) (EXAMPLES) 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00" (1). Dry Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 11, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. (2). Escutcheon Finish applies to sprinklers provided with escutcheons. (3). 286F/141C and 360/182C temperature ratings apply to non -recessed sprinkler assemblies. * Eastem Hemisphere sales only. TABLE B PART NUMBER SELECTION SERIES DS -1, STANDARD RESPONSE, STANDARD COVERAGE, DRY TYPE SPRINKLERS (Use Prefix "I" for ISO 7-R1 Connection, e.g., I-60-961-1-180) ® 2007-2008 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446