HomeMy WebLinkAboutPP - 555 ANDOVER PARK WEST STE 201 - IN DEMAND INTERPRETING - PERMITS AND PLANS555 ANDOVER PARK WEST STE 201
ASSOCIATED PERMITS
M16-0155
D16-0152
16-S-150
4 tit
SITE LOCATION
CITY OF TUKWILA
FIRE MARSHAL'S OFFICE
206-575-4407
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
^ ,�,, jj '' ,, 11i,�� King Co. Assessor's Tax No.:
Site Address: 655. 41 SOV?i% Park 1/lk&i" Suite Number: 20/ Floor: 2r' F.)
Tenant Name: I fl YYY 11Y Y'? r,'\ \ flG New Tenant? ❑ - Yes ❑ - No
X
Property Owner's Name: )t Pc-cn X' (,Orl�orl L r'e,
Mailing Address: l5 O C ..\ 1 -corn lel Sf .
CONTACT PERSON -if there are questions about the submittal.
Name:
Cat Dbi n)
San branGiSCO , CA '9/1/
City State Zip
'j� Day Telephone: 412.c • 7 0 /'7co(a�
Company Name: C�cpljr1 1)TP_ Tr c, )A.c.
Mailing Address: ?r) 1:, # ‘2)1 m 1 1 1 C.Q , /oA .IRSOU,
O%2.
City State Zip
E-mail Address: essl WP Crown . Cu %Y% Fax Number: 1/2... '748/ • g& S
V UV$. 09'56/2
Contractor's City of Tukwila Business License number:
Total number of new/relocated devices or sprinkler heads: 2 -
Valuation of Project (contractor's bid price): $ 50
Scope of Work (please provide detailed information):
C2) hetWS
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING 0 NE/(R.�OR AUT ZED AGENT:
Signature: .E%'iLa_
Print Name:
Jessica g)hirlson
Plan Permit App.doc
Day Telephone:
Date: 7 f8','d_
Z/26.4'8/7649
8/22/14 TFD FP Form 8
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
Allo-o�n
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project: I
Sprinklers:
Type of Inspection
Address:Contact
Suite #: '-C
%l -0I
Person:
Special Instructions:
Occupancy Type:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
(//r 6/-1 )“- 0.10n -472)g_ /...4 5 Fyn.
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: / , 4 - -
Date: f f/Z V.,—
Hrs.:
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
(
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:
110 1�2�
I
el
Type of Inspe ion:
--.,/r___, _vt ves>Ae_.—
Address: 533"
Suite#: (9)
/1P Id
Contact Person:
Special Instructions:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
fu,_,(41
Se
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
1
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
Date:
7/act//,4
Hrs.:
(
1
Inspector:
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
//-3 -/Sa
�Dleo — O t -
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:
4m iv:
iw
Type of InnssDection:
c— i/c/_
Address:ND
Suite #: _gs5 /W
2 FL. .
Contact Person:
Special Instructions:
01
Phone No.:
7\6)
pproved per applicable codes.
COMMENTS:
Corrections required prior to approval.
a< 71 0 6,e___40 -
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspecto& /74ef J
Date: 2/7,,z..j,
Hrs.: 1. d
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F..D. Form F.P. 113
J
ReRabid
Bulletin 110 Rev. W
Model G
Automatic Sprinklers
Spray Upright,
Spray Pendent
And Conventional
Product Description
The Reliable Model G Automatic Sprinkler utilizes the
center strut solder in compression principle of construc-
tion. The fusible alloy is captured in the cylinder of the
solder capsule by a stainless steel ball. When the fusible
alloy melts, the ball moves into the cylinder allowing the
cylinder to fall away from the sprinkler. When this happens,
the lever is released to spring free from the sprinkler so
that all of the operating parts clear from the waterway al-
lowing the deflector to distribute the discharging water.
Except for the parts in the cylinder as mentioned above,
the sprinkler components are made from copper based
alloys for maximum corrosion protection. Lead plated, wax
coated or wax over lead plated sprinklers are available for
specially severe environments. Chrome plated sprinklers
are available for decorative purposes.
All sprinklers are individually hydrostatically tested. All
sprinklers are identified as to their fusing point by mark-
ings that appear on several of the operating parts and by
an identifying color that appears on the frame.
Sprinkler Types
Standard Upright—This deflector configuration is normal-
ly used with exposed piping installations. Water is distrib-
uted laterally and downward in a wide pattern approximat-
ing a hemisphere which is completely and uniformly filled
with water in the form of small drops or spray.
Standard Pendent — This deflector configuration is nor-
mally used where the space above the piping is limited
or where a concealed piping installation is employed. The
discharge characteristics of the standard pendent are
virtually identical to the standard upright as described
above.
Large and Small Orifice —By varying the orifice size, a
large or small orifice sprinkler is created that will distrib-
ute as much as 40% more water or 65% less water than
the normal 1" (15mm) orifice sprinkler.
Conventional —This deflector configuration is used pri-
marily in those countries where the LPC installation rules
have precedence. The sprinkler is designed to distribute
a portion of its water discharge upward against the ceil-
ing with the balance downward. It may be installed in
either the upright or the pendent position. Sprinklers with
conventional deflectors are available with orifice sizes
corresponding to light, ordinary and extra—high hazard
installations.
Upright
t
•
Small Orifice Upright
Pendent
Conventional
Application and Installation
Standard sprinklers are used in fixed fire protection sys-
tems: Wet, Dry, Deluge or Preaction. Care must be exer-
cised that the orifice sizes, temperature ratings, deflector
styles and sprinkler spacings are in accordance with the
latest published standards of the National Fire Protection
Association or the approving authority having jurisdiction.
The sprinklers must be installed with the Reliable Model
D Sprinkler Wrench. Any other type of wrench may dam-
age the sprinkler.
The approvals or listings of Reliable Automatic Sprin-
klers by major approving organizations are shown in the
tabulated list provided on the back of this bulletin.
Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
M 'AO 01- I- u!Ielln8
Technical Data
Sprinkler Type
"K" Factor
Sprinkler
Height
Special Application Finishes
Approvals
Sprinkler Identification
Number (SIN)
US
Metric
SSU
°F
SSP
Standard–Upright (SSU) and Pendent (SSP)
°C
Ordinary
135
57
100
38
Black
Ordinary
Deflectors Marked to Indicate Position
74
100
38
Uncolored
Intermediate
212
100
150
66
1/2" (15 mm) Standard Orifice with 1/2" NPT (R1/2) Thread
5.62
81.0
2 7/6" (73 mm)
1, 2,
3, 4,
5, 6, 7
R1025
R1015
7/16" (11 mm) Small Orifice with 1/2" NPT (R1/2) Thread
4.24
61.0
2 7/6" (73 mm)
1, 5
R1023
R1013
3/6„ (10 mm) Small Orifice with 1/2 NPT (R1/2) Thread
2.82
40.6
2 7/6" (73 mm)
1, 2,
5
R1021
R1011
5/16" (8 mm) Small Orifice with 1/2" NPT (R'/2) Thread
1.98
28.5
2 7/8" (73 mm)
1, 5
R1022
R1012
17/32" (20 mm) Large Orifice with 1/2" NPT (R1/2) Thread
7.96
114.7
2 7/8" (73 mm)
1, 2,
5
R1026
R1016
17/32" (20 mm) Large Orifice with 3/4" NPT (R3/4)Thread
8.20
118.2
2 15/16" (75 mm)
1, 2,
5
R1027
R1017
20 mm XHH with 20 mm Thread
8.20
118.2
75.4 mm
3, 4,
5
R1027
R1017
10 mm XLH with 10 mm Thread
4.10
59.1
73 mm
3, 4,
5
R1024
R1014
Conventional—Installed in Upright or Pendent Position
10mm XLH with 10mm Thread
4.10
59.1
73 mm
4
R1074
15mm Standard Orifice with (R1/2) Thread
5.62
81.0
73 mm
3, 4,
5, 7
R1075
20mm XHH with (R3/4) Thread
8.20
118.2
75.4 mm
3, 4
R1077
Temperature Ratings
1) Frame color does not apply to painted or p ated sprinklers
–Use sprinkler rating as identified on operating parts.
Finishes (1)
sprinklers with soap and water, ammonia or any other clean-
ing fluids. Remove any sprinkler that has been painted (other
than factory applied) or damaged in any way. A stock of spare
sprinklers should be maintained to allow quick replacement of
damaged or operated sprinklers. Prior to installation, sprinklers
should be maintained in the original cartons and packaging un-
til used to minimize the potential for damage to sprinklers that
would cause improper operation or non -operation. Use only the
Model D Sprinkler Wrench for sprinkler removal and installation.
Any other type of wrench may damage the sprinkler.
Standard Finishes
Sprinkler
Maximum
Special Application Finishes
Classification
Rating
Ambient
Temperature
Frame (1)
Color
°F
°C
°F
°C
Ordinary
135
57
100
38
Black
Ordinary
165
74
100
38
Uncolored
Intermediate
212
100
150
66
White
High
286
141
225
107
Blue
1) Frame color does not apply to painted or p ated sprinklers
–Use sprinkler rating as identified on operating parts.
Finishes (1)
sprinklers with soap and water, ammonia or any other clean-
ing fluids. Remove any sprinkler that has been painted (other
than factory applied) or damaged in any way. A stock of spare
sprinklers should be maintained to allow quick replacement of
damaged or operated sprinklers. Prior to installation, sprinklers
should be maintained in the original cartons and packaging un-
til used to minimize the potential for damage to sprinklers that
would cause improper operation or non -operation. Use only the
Model D Sprinkler Wrench for sprinkler removal and installation.
Any other type of wrench may damage the sprinkler.
Standard Finishes
Bronze
Chrome
White (2)
—All Temperature Ratings
—All Temperature Ratings
—All Temperature Ratings
Only Frame and Deflector are Painted
Special Application Finishes
Bright Brass Plated
Black Plated
Polyester Coated (2)(4)
Lead Plated
Wax -Coated (3)
Wax -Coated Over
Lead Plated (3)
—Only frame, deflector and cap are plated. 135°F (57°C), 165°F
(74°C), 212°F (100°C) Temp. Rating.
—Only frame, deflector and cap are plated. All Temp. Ratings.
—Only frame and deflector are coated.
—165°F (74°C), 212°F (100°C) and 286°F (141°C) Temp. Ratings.
—165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax.
—165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax.
(4)
Other colors and fin'shes are available. Consult factory for details.
UL listed and NYC MEA Approved only.
212°F (100°C) brown wax may be used on 286°F (141°C)
sprinklers when maximum ambient temperatures do not exceed 150°F
(66°C). UL Listed; FM Approved, NYC MEA 258-93-E.
FM Approved for R1027 only.
Maintenance
Model G Sprinklers should be inspected and the sprinkler
system maintained in accordance with NFPA 25. Do not clean
Approval Organizations
1. Underwriters Laboratories, Inc. and UL
Certified for Canada (cULus).
2. Factory Mutual Research Corporation
3. Loss Prevention Council
4. Pleniere Assemblee
5. VdS SchadenverhOtung GmbH
6. N.Y.C. BS&A No. 587 -75 -SA or
N.Y.C. MEA 258-93-E
7. EC Certificate: 1438 -CPD -0054 (R1015)
1438 -CPD -0053 (R1025)
1438 -CPD -0052 (R 1075)
1438 -CPD -0056 (R 1077)
Ordering Information
Specify
1. Model G
2. Deflector
• Upright
• Pendent
• Conventional
3. Nominal Orifice
4. Inlet Thread
5. Temperature Rating
6. Finish
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fre Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
ReIiabkC
Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
eRecycled
Paper
Revision lines indicate updated or new data.
EG. Printed in U.S.A. 04/15 P/N 9999970005
REDUCED
• CONFERENCE ROOM
119'8'X23
EXISTING BUILDING CORE
EXISTING CORRIDOR PARTITION
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
NEW BIS SOUND PARTITION
NEW WS WALL MOUNTED DUPLEX ELECTRICAL
OUTLET (E a EXISTING)
NEW 8!S WALL MOUNTED COMBINATION
VOICE/DATA OUTLET
REWIRED EXISTING 8/S LIGHT SWITCH
SECOND FLOOR PLAN
‘'
i'
NORTH
no 5A
0
Design per NFPA 13, Light Hazard - Offices
All materials to be new, U L listed, and F M approved
All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means
All heads to be at least 6' apart
• 2 — Add Reliable Model G Standard Response 165° Semi -Recessed Pendents 1/2 x 1/2
• E — Existing no change
HILTI KWIK BOLT
j'_ALTHREAD ROD
PIPE RING
HILTI KWIK -BOLT
ACCEPTED
Without Comments
As Noted in Rei
Per The Attached Letter
These plans ha‘ie been remewed by Tne Tukwila Fire
Prevention Burea , ; > ;ti^{orma�r},ce w,t'1 current City -
sr3ndards Accerr , - ,.abject to errors and
C-Th5S ons Which u orize violations of aaopted
c.�naards an; c c Tie respons,00;Cy for the
EiJequacy Q` oes 9 W _ 1 y with tre designer
kid,tions deieoo ; -. :',s,cns ro these orawings after
tf is date ve : tr} ; -....7and will require a
resuornitta t',` 400 suosequeot approval
Final acceptance co fielu test and Inspect,on by
The Tukwila Fire P, e, e it : our¢aa
%-19 '/S- 1
Date By J f
TUKWILA FIRE DEPARTMENT
F,o se m11 206-575-4407 and
5ve th Fire Permit No:
l�613-0
and exact armless for shut-
down or gran approval.
TEWASINGTONCERTIFICATA
TES OF SOOMPETENOY
FIRE PROTECTION SPRINKLER SYSTEMS
John J Abel
97600591 -EG Level 3
Protection, Inc
Expires
12/91/18
•
CROWN
FIRE PROTECTION
INCORPORATED
P 0 BOX 12113
MILL CREEK, WASHINGTON 98082-0113
PH (425) 481-7669
Indemand Interpreting
Southcenter Corporate Square
555 Ana over ?arecss
2nd floor
Suite 2n)
Tukwila, WA
P
TU KIV
DATE 7, ISs W
DRAWN 6,;
SCALE 51 3/
1 RC1
AID
19 2016
ILA FIRE
2tzS-FT
LEGEND
EXISTING BUILDING CORE
EYJSTNG CORRIDOR PARTITION
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
NEW BS SOIJIRI PARTITION
10- E NEW BSWALL MOUNTED DUPLEX ELECTRICAL
CURET (E=EXISTNG)
td NEWBSWNLMOUN0EO COMBINATION
VOICEIOATAOUTLET
Xfl REWIRED EXISTING BSLINTSWITCH
®SECOND FLOOR PLAN
N
Design per NFPA 13, Light Hazard - Offices
All materials to be new, U L listed, and F M approved
All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means
All heads to be at least 6' apart
• 2 — Add Reliable Model G Standard Response 165° Semi -Recessed Pendents 1/2 x 1/2
• E — Existing no change
HILTI KWIK BOLT
`ALLBTHREAD ROO
/PIPE RING
HILTI KWIK -BOLT
ACCEPTED
Without Comments
❑ As Noted In Red
❑ Per The Attached Letter
71 ese plans hai,e heen renewed b. Tne Tukwila Fire
++eiienvon buret. - ..^°ormarce with current City
sa^dards Accei r ;,bject to errors and
c nus ons which 0,1 'o ,: Zr onze ' diabors of adopted
cmdards and c c =^r. s The respons,e+It for the
a legaacy d` oe; e - :o;al 1 with tr e designer
idtinns de. s - : slcr; ro these drawings ate
tf Is date wa VC d t : ,c eDtan ce and will require a
resuomitta o` -: niar suosequent approval
Final acceptance 1.:,_CI-6C t� field test and Inspection by
The Tukwila Fire Pi e, a Tt : Dveau
Date
7-r 9 �I" By / 3-1 T
TUKWILA FIRE DEPARTMENT
F oast call 206-575-407 and
c, vs res Fire Permit No:
J -Is -o
and exact a .•ess for shut-
down or res�zzr&i ' approval.
CERTIFICATE BTCOMPPET ENCS
FIRE PROTECTION SPRINKLER SYSTEMS
CROWN
FIRE PROTECTION
INCORPORATED
P 0 BOX 12113
MILL CREEK, WASHINGTON 98082-0113
PH (425) 481-7669
Indemand Interpreting
Southcenter Corporate Square
555 An:b r ?ark Viec.•i-
2nd floor PAID
Suite 20) UL i 2Oj
Tukwila, WA TUFO''¢L.A F!RE
DATE 7, IS •Ib
DRAWN W
SCALE a 3Z
I pc 1