Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 17320 SOUTHCENTER PKWY - ULTA COSMETICS - PERMITS AND PLANS
17320 SOUTHCENTER PKWY ASSOCIATED PERMITS 15-S-038 15-F-057 05-F-196 05-S-167 99-F-243 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 2623049110 Site Address: 17320 Southcenter Parkway, Tukwila, WA Suite Number: Store 191 Floor: Tenant Name: V 6t(A- 1)-2Q2/U14,- New Tenant? 0 - Yes ❑ - No Property Owner's Name: Parkway Supercenter Mailing Address: 301 Minkler Blvd, Tukwila, WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address: 1743 First Ave South, Seattle, WA 98134 City State Zip E-mail Address: kveliz@guardiansecurity.com Fax Number: 206.628.4990 Total number of new/relocated devices or sprinkler heads: 4 Valuation of Project (contractor's bid price): $ 2000 Scope of Work (please provide detailed information): Adding 4 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDINGO, ► R OR AUTHORIZ Signature: AGENT: Date: l 1 t 6 J Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 1,3Z D g . Suite Number: V4 Floor: / s Tenant Name: i1LrA New Tenant? ❑ - Yes 12No Property Owner's Name: l,s 170411.414( Mailing Address: 3 535 Acraiu A- (3Lv D $ c jjZO 8ALEv9.86do City State Zip CONTACT PERSON -if there are questions about the submittal. Name: -rp, e1 -vs 3 1--es/3 Nt2 14- Day Telephone: de's ' (3 9 • 5811 Company Name: 4RU+&-R etAi s rg ve.n cv.,( Mailing Address: 7A5 5 5. gap 41" S f Ke11' L0,4 `7 3 City State Zip 1 E-mail Address: ! fA»-4j&. 6.4.61 rt'c+,s41^ <A61 •C-sarv) Fax Number: 253 872- 7z7 7 Contractor's City of Tukwila Business License number: US ci a (D 3L1 Total number of new/relocated devices or sprinkler heads: 192 Valuation of Project (contractor's bid price): $ /3, 060 Scope of Work (please provide detailed information): Adc%1ny 10 ', Caac. SSP . Fie/xaf+oJ o'1R ,e.0 a cea , 55P 4 nefievdtpi 83 lark Scow -9 6C W t r// Nat) & Fi GoNC, SS? ?b 14c-coev24d rE coe ,41 t<) 7'61-14 / perm" 1- PZ R J FPA- 4 L -06 -A -L, 4lf-3, PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO ZED AG T: Signature: �` - �j Date:/2/l5 Print Name: vis D. / .,g61_ Day Telephone: rOi 0(o • (0341.5-V7 Plan Permit App.doc 8/22/14 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Ulta Cosmetics 17320 Southcenter Parkway Permit No.: 15-S-038 Date: March 12, 2015 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 21 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. WASHINGTON SURVEYING & RATING BUREAU 200 1st Avenue West tel 2O6.217.WSRB Suite 500 fax 2O6.217.WFAX Seattle, WA 98119 web www.wsrb.com Underwriting Information, Filings, & Property Loss Costs Jose A. Buitrago Senior Field Representative/Plan Review jose.buitrago@wsrb.com (206)-273-7157 September 15, 2005 PLAN SHEETS 1 of 1 SUBJECT Ulta # 191 - Tenant Improvement @ Tukwila Supercenter 17320 — Southcenter Parkway Tukwila, Washington The attached plans have been Accepted as meeting requirements for classification as a sprinklered risk: The following revisions or additions to the design as shown would qualify the protection for improved rates based upon information shown on these plans. Completed copies of the Contractor's Material and Test Certificates for both the overhead piping should be submitted to this Bureau, including tests of the local alarm and main water supply test pipe (2 -inch). All piping, valves, and fittings should be listed and labeled by UL for fire service and installed, tested, and flushed in accordance with NFPA standards. A minimum temperature of 40°F must be maintained with a thermostatically controlled heating system in all areas containing wet pipe sprinkler equipment. 1. Hangers should be installed according to UL listing and as specified by NFPA 13. 2. Extend sprinkler protection to all areas including exterior eaves, soffits, canopies, blind and roof spaces, and to roof skylights. 4P/P os Cj6 NI C, tt . '3erving thM roperty ani�p;ups'neeInidustry Since 1911 Federal Firesafety, Inc. 19231 36th Ave. W. Suite B -21J) Lynnwood, WA 98036 Phone (425) 670-2724 Fax (425) 670-2675 Cosco Fire Protection, Inc. 10910117' Place N.E. Kirkland, WA 98033 Phone (425) 827-9654 Fax (425) 827-7474 Subsidiary Companies of Consolidated Fire Protection. LLC U Ita 17320 South Center Parkway Tukwilla, WA 98188 Fire Alarm System Submittal Material Supplier Federal Firesafety 19231 - 36th Avenue, West Suite B-200 Lynnwood, WA 98036 Ph (425) 670-2675 Fax (425) 670-2675 Installation Contractor: Globe Electric 232 S.W. 43rd Street Renton, WA 9805 Ph (425) 228-8102 No., Part No. Description 1., SIGA-PS Photoelectric Smoke Detector 2. SIGA-SB Smoke detector base 3. GC-HDVM Ceiling Mount Hom/Strobe 4. GC -VM Ceiling Mount Strobe , 5. _ SI OA CT:2 Dual Input Module Material Supplier Federal Firesafety 19231 - 36th Avenue, West Suite B-200 Lynnwood, WA 98036 Ph (425) 670-2675 Fax (425) 670-2675 Installation Contractor: Globe Electric 232 S.W. 43rd Street Renton, WA 9805 Ph (425) 228-8102 BATTBttz C:ALLULF E1ONS Project HALLMARK 11230 50UXNCENTER PI<W Y Date : '1- 19-99 By : KLEIN) Manufactuer: X11- EI FF KNIGHT Model 5395 Total Supervisory: Supervisory: ZH hrs. X Alarm -353 hrs . X Add Safety 12% = • 223.9 Total MA. Hrs. Required: 2Q$cf-3 devided by ?POO Battery Selected: C2} 17..V rA1-1 '5 '183 75 12)00 • 65 .4 Total alarm: '188 System Total 16�� y equals Z•,C) AH SUPERVISORY CURRENT ALARM CURRENT 4 QTY MODULE/DEVICE CIRCUIT NAME MA Unit TOTAL MA UNIT TOTAL 1 1 5 3 G S EXPANDER MEL '15 75 100 100 28 NS2'-I1515VJ-FR PIE7.\0/.5T 0t?E 8(0 (voo 3 i 4 5 6 7 8 9 10 11 12• 13 , 14 15 16 17 18 Total Supervisory: Supervisory: ZH hrs. X Alarm -353 hrs . X Add Safety 12% = • 223.9 Total MA. Hrs. Required: 2Q$cf-3 devided by ?POO Battery Selected: C2} 17..V rA1-1 '5 '183 75 12)00 • 65 .4 Total alarm: '188 System Total 16�� y equals Z•,C) AH CORRECTION NOTICE/REINSPECTION FEE Inspector: Permit number: TUKWILA FIRE MARSHAL'S OFFICE Office: 206-575-4407 Fax: 206-575-4439 Email: Fire Marshaltukwilawa.2ov Business Name: 2c -p/1-0// Bp_or, spv2fr•ik/o/i- g66 -a_ thrti,r ta641-6--t 4-1- (x7-4-4 ef--4-7/7-7 Ris-t-r2- geervt.. Type of Inspection: Ver Locatio �� 6 p,. 9 Date : 1 (/ 44 Contact Person : • i n(k c CA -A._4(1‹ c--, Phone No. : act, 57-5 iVv y ACTION REQUIRED 2c -p/1-0// Bp_or, spv2fr•ik/o/i- g66 -a_ thrti,r ta641-6--t 4-1- (x7-4-4 ef--4-7/7-7 Ris-t-r2- geervt.. (�32d Sc- pki/vi, . 4f-- CJA4g•d-e- - FaA t (di -es g 5k(ito-#4,10 . 2-3-?-gc(Mge6 _ _ CORRECTION OF FAILURE T C Signature: IT REQUIRED BY : SULT IN THE ISSUANCE OF A C Billing/Mailing Address : /TICKET. Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will rece ve an invoice°from the ty of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Reinsp Fee2.doc Revised 6/17/14 T.F.D. Form F.P. 100 .•111111.1111111111•1111111111111111111•111111••••••••••••••••••••111111110••••• IOU -Ca" EX STMC--) STOCKROOM N.IL RUIKLER ROOM STOCkROOT\A -2 CORRIDOR_ r \NMEkIS _ST6C_KR(Y3f\A *1 2* 30 PAINTED ON NG 1.000.1 CLIAAPARR • SALES 0 ) .4, LIN Li RI PLAT MODULE PULL -0 e--1 MOR PL AN _SCALE : PULL EOLR. (-) 1 o- f Of F I RST LAST ALARM CIRCU IT PED/E. PIEZIO /STUN BE EOL R FIRST LAST AUDILE CIRCUIT MODEL REL AUX IOU' Oil -T3 1 dUT UTI1(11 RELAY 111/I P LIT IMPUT 1 1 1 117_131 11 151(00 1 819 110111 112.113 11911511(0111-TIATF91 F ACP IL) uJ 0 PLAN NO ...5C.A LE NOTES'. I - PUDU1LE. DEVICE TO 13E. MOIANTED AT 80" AFF. Z -ALL DEVICES TO EE 5 UPERV ED. 3 - ALL TO EE FIRE FATED CAELE - SUILDIN CI IS FULLY _5F KLERED. - DV/CT DET ECTORS IF SkEQ, C an-te_cz.s. ISYM MY DESCRIPTION MANIAFACTURE 1/180EL 1 EXPANOC-.V, PANEL ---73ILENT K NIG I -IT 5395 1 1. CONTROL REIAY t,,A 0 MILE. EDWARDS SIGA- CR 1 3 _SINGLE 1NPRT MODULE EDWARDS 51(.3R - CT I IEZI 0 STROBE WHEELO K N52L1151.5W -R 3 ?ULL TATION EDEZPLHOS 1 ACCEPTED Without Comments As Noted Ir, Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings forsubsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: --y? .,/1 By: TUKWILA FIRE DEPARTMENT Please cat: 575.4407 and give this job No. 9 and exact address for shut. down or restoration approval. FILE JLJUL Z71999 0 HALLMARK 192.13 SOUINCF_.N TER PARKWAY SIAPER.C.EN TE.R. UKW ILA , WASH ciRIPIR SCALE, NOTE. DATE -I - 'I APPROVED BY: C TY 'OF TIAKVVIUA DRAWN evIDW K RRE..- ALARM _7 I INC.. Ztic5C 8-111-I AVE S KENT WA. '15012.. DRAWING NUMBER, . Z818'1:71 RTU 3 C . 110 c TO RISER ROOM C TO RISER ROOM RTU 4 c RTU 1 RTU 2 DUCT DET. MONITOR MODULES TO RISER ROOM C TO RISER ROOM C 110 FIRE ALARM PLAN LLTA SUITE SCALE: 1/8" = 1'-0" PROJECT: Ulta Panel: Edwards BPS -6 Date: October 3, 2005 CIRCUIT: H1 Notification Appliance Circuit Detail HI CURRENT TOTAL= 1984 QTY Device Type Alarm Current Alarm Total Wre Size Wire Length Voltage at EOL Circuit Total 6 GC-HDVM @ 95cd 212 1272 0 Multiply lines E and H Total Alarm AN SMOKE DETECTOR G 000E4 SIGA—PS 0.1652672 DEVICES= 6 TOTAL mA= 1272 14 253 21.94681392 1272 H2 QTY Device Type Alarm Current Alar Total Wre Size Wre Length Voltage at EOL Circuit Total 4 GC -VMI @ 15cd 63 252 0 Multiply lines E and H Total Alarm AN SMOKE DETECTOR G 000E4 SIGA—PS 0.1652672 1 GC -VM © 30cd 90 90 TOTAL FIRE ALARM POWER SUPPLY X 90 450 BOA MTN 3/0 RING CR 4/0 Bo. 2 GC-HDVM @ 75cd 185 370 -�++•- 7 END OF UNE AS NEEDED Au)alia Device Cuent DEVICES= 7 TOTAL mA= 712 14 164 23.25502016 712 GEN H,RATI NOTI-14S 1 WIRING ROUTES ARE FOR REFERENCE ONLY. DEVICE CIRCUITS HAVE BEEN ENGINEERED AND CALCULATED FOR CURRENT DRAW AND VOLTAGE DROP. PANEL, ANNUNCIATOR, AND POWER SUPPLY LOCATIONS SHALL BE MOUNTED IN LOCATIONS SHOWN. ANY DEVIATION OF CIRCUITRY OR LOCATIONS FROM THOSE SHOWN SHALL BE PRESENTED, IN WRITING, TO FEDERAL FIRESAFETY INC. FOR APPROVAL AND REVISION. ADDITIONAL EQUIPMENT, ENGINEERING, AND TECHNICAL LABOR REQUIRED SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 2 ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. THE INSTALLATION SHALL MEET THE REQUIREMENTS OF THE AHJ AND LOCAL CODES. 3 WIRING SHALL BE CUT AT EACH DEVICE LOCATION. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. 4 ALL WIRING TO BE IDENTIFIED, FREE OF SHORTS, GROUNDS AND OPENS PRIOR 5 TO FEDERAL FIRESAFETY'S SCHEDULED FIELD WORK. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 3 FEET OF A SUPPLY (HOT AIR VENT OR 18 INCHES OF A FLUORESCENT BALLAST, REGARDLESS OF LOCATION SHOWN ON DRAWINGS. 6 FIELD VERIFY SPRINKLER WATERFLOW, TAMPER VALVE, AND PIV SWITCH LOCATIONS. 7 FIELD VERIFY HVAC FAN SHUTDOWN REQUIREMENTS AND DUCT DETECTOR LOCATIONS PER NFPA 72 } 8 ADDRESSABLE DEVICE(S) SHALL NOT BE LOCATED NEAR A HIGH ELECTRICAL OR MAGNETIC FIELD GENERATING DEVICE SUCH AS TRANSFORMERS, HID LIGHTING, ETC.... REGARDLESS OF LOCATION SHOWN ON DRAWINGS. 9 PER NFPA 72 SECTION 2-3.6,1.3 SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEANUP OF ALL TRADES IS COMPLETE AND FINAL. (PLEASE SEE EXCEPTION) 10 IT IS HIGHLY RECOMMENDED THAT ANY PVC CONDUIT USED TO HAVE A BONDING WIRE PULLED THROUGH TO BOND ALL METALLIC RACEWAY SECTIONS, THIS WIRE NOT SHOWN ON FIRE ALARM DRAWINGS. 11 THE DATA PAIR TO ALL SIGNATURE TYPE DEVICES IS DATA & 24VDC POWER. SHIELDING IS NOT REQUIRED. THE DATA CIRCUIT IS POLARITY CRITICAL & THE DEVICES MUST BE WIRED PROPERLY FOR IN & OUT AS PER MANUFACTURERS INSTALLATION INSTRUCTIONS. THE DATA CIRCUIT HAS A LIMITATION OF 63 T-TAPPS PER LOOP. THIS LIMITATION MUST BE FOLLOWED. 12 ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC 70 AND LOCAL CODES. 13 EQUIPMENT LISTED ON LEGEND SHALL BE SUPPLIED BY FEDERAL FIRESAFETY INC. EQUIPMENT LISTED AS SUPPLIED BY OTHERS SHALL BE FURNISHED AND INSTALLED BY THE CORRESPONDING TRADE. 14 FIRE ALARM CONTROL PANEL SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF A FEDERAL FIRESAFETY TECHNICIAN. 15 DETECTORS & MODULES DO NOT HAVE FIELD SETTABLE ADDRESSES. ADDRESSES ARE SET VIA SOFTWARE CORRELATING TO A BAR CODE ASSIGNED TO EACH DEVICE. DEVICE BAR --CODES, LOCATED ON EACH DEVICE, SHALL BE ADHERED TO A CLEAN SET OF DRAWINGS FOR FEDERAL FIRESAFETY USE. BAR CODES MUST BE GIVEN TO FIELD TECHNICIANS 5 WORKING DAYS BEFORE SCHEDULED PANEL PROGRAMMING. 16 REGARDLESS OF ANY PUBLISHED SCHEDULE, ALL MILESTONE EVENTS SHALL BE CONFIRMED BY THE ELECTRICAL CONTRACTOR WITH FEDERAL FIRESAFETY INC. FEDERAL FIRESAFETY INC. FIELD TECHNICIAN MUST BE SCHEDULED WITH THE PROJECT MANAGER WITHIN 10 WORKING DAYS OF ANTICIPATED START DATE. 17 FIRE ALARM FINAL TESTING CANNOT BE COMPLETED UNTIL THE FOLLOWING ITEMS t-IAWF RFFN (`CAAPI FTFn FIX" TNF OF ERAL CONTRACTOR A) FINAL CLEANUP _ C) ALL CARPET INSTALL TD S INSTALED F 1 L E Alta ~ttjTALED Without Comments As Noted In 'Red Per The Attached Letter These plans have bttY1 ieviewed by The Tukwila Firms Prevention Bureau for oonformance with current city standards. Acceptance is subject to errors ar.:' omissions whi6fl do not authorize violations c. standards and ordinances The r orr adequacy of design rests totally with = i Additions, deletions or revisions 10 these this date will void this acceptance and wia resubmittal of revised drawings for subsequent Final acceptance Is subject to field test and inspociion The Tukwila Fire Prevention Bureau. Date: IC/74"5— By: 'pi.S %4-5" A C D E F G H J K Project: Ulta Panel: Edwards BPS -6 Date: October 3,2005 TUKWILA FIRE DEI -ARI MEWM Please call: 575.4407 and give this job No. and exact address for shut. down or restoration approval, NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Fa'.ure of test will resin;` in a Re,-r:speion terminat.0 „t;=1 ._._j. Module/Device Qty Standby (mA) Total Standby (mA) Alarm (mA) Total Alarm (mA) Power Module 24 0 90 90 190 0 Multiply lines E and H Total Alarm AN SMOKE DETECTOR G 000E4 SIGA—PS 0.1652672 Add lines G and I Total Standby and Alarm AH 0 SMOKE DETECTOR, DUCT BY D s 0 TOTAL FIRE ALARM POWER SUPPLY X 90 450 BOA MTN 3/0 RING CR 4/0 Bo. 0 - 3 MANUAL PULL STATION zoo SRO 450 DEER BOX ,RUN SINGLE GANG Mw RINGMODEL: -�++•- 7 END OF UNE AS NEEDED Au)alia Device Cuent X 0 450 BOX M1117 SINGLE GANG MUD RING 0 2 DUAL MONITOR MODULE MODEL. sIcA cTz « 450 BOX MTN 0NE BANG MDG RING yX 4 FIRE ALARM STROBE WITH FIELD SET CD OPE1: cc Nofificati n Appliance Load (Max Total) 0 9 1984 450 Box .TN SIRG,E GANG MUD RING X WATERFLOW ALARM X X X I I Total(A)= 90 Total(B)= 1984 CALCULATION Total current ratings of all devices in system (line A + line B + InciC) 90 1884 Notal current stings 4d to amperes 7 x .001) 0.24® Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). ours p 24 1 ANN 1 Multiply lines E and F Total Standby AH 2.16 0.0833 Alarm sounding period in hours (5 mins+ .0833 hours) Multiply lines E and H Total Alarm AN SMOKE DETECTOR G 000E4 SIGA—PS 0.1652672 Add lines G and I Total Standby and Alarm AH 23252672 SMOKE DETECTOR, DUCT BY D s Multiply line J by 1.2 (20% extra insurance to meet desired performance) 2.79032064 X Amp Hour Battery Provided 4 DEVICE LEGEND DEMCE DESCRIPTION MOUNTING IFACPI SMOKE DETECTOR. ALARM FIRE ALARM CONTROL PANEL MODEL, 0073 SEE MANUFACTURERS DATA 1 BPS] BOOSTER POWER SUPPLY MODE BRSB „ Cc, SEE MANUFACTURERS DATA 1 ANN 1 FIRE ALARM REMOTE ANNUNCIATOR MODEL, 3ANN—LOO SEE MANUFACTURERS DATA s0 1 SMOKE DETECTOR G 000E4 SIGA—PS 450 BOX 8074 3/0 RING OR 4/0 BOX s( z -D_ 4 SMOKE DETECTOR, DUCT BY D s S=E M^NUF^c*UREas DATA QHEAT X DETECTOR MODEL, SAGA 404ES 450 BOA MTN 3/0 RING CR 4/0 Bo. - 3 MANUAL PULL STATION zoo SRO 450 DEER BOX ,RUN SINGLE GANG Mw RINGMODEL: -�++•- 7 END OF UNE AS NEEDED w LAST DEVICE X MONITOR MODULE MODEL. SGA CT, 450 BOX M1117 SINGLE GANG MUD RING <u 2 DUAL MONITOR MODULE MODEL. sIcA cTz « 450 BOX MTN 0NE BANG MDG RING yX 4 FIRE ALARM STROBE WITH FIELD SET CD OPE1: cc RING❑ 4So 000 wTN SINGLE GANG MUG F6 9 FIRE ALARM HORN/STROBE WITH FIELD SET c D D,rM n 450 Box .TN SIRG,E GANG MUD RING SUBSCRIPT E = EXISTING WP = WEATHER PROOF MOUNT C = CEILING MOUNT N.A.0 = NOTIFICATION APPLIANCE CIRCUIT S.L.C. = SIGNALLING LINE CIRCUIT (INTELLIGENT LOOP) NOTE! THE SIGNATURE LOOP CKT (7uv) 1S POLARITY AND IN -OUT CRITICAL. INSTALLER TO TAG EACH 'INCOMING' PAIR W/COLORED TAPE AT EACH DEVICE. THIS CKT IS T -TAPABLE, BUT ONLY A LIMITED NUMBER OF TIMES (63 PER LOOP) 8111.0 DO NOT ATTEMPT TO T -TAP ON A DETECTOR BASE OR MODULE ITSELF; A 'PIGTAIL' SPLICE MUST BE MADE IN J -BOX. DROPS TO SINGLE DEVICES GENERALLY SHOWN AS 2Z(X) WHICH IS 4 WIRES - 1 PAIR OUT. NOTE DEVICE ADDRESSING: EACH SIGA DEVICE HAS A REMOVABLE BAR-CODE 'STICKER'. INSTALLER TO REMOVE STICKER & PASTE ONTO COPY OF DRAWINGS AT THE RESPECTIVE DEVICE LOCATION NEXT TO DEVICES' 4 DIGIT ADDRESS ON DRAWING, SIGA-LED REMOTE LAMP (IF REQUIRED) FLOW, TAMPER OR ANY NA. CONTACT DEVICE FORM '0' RELAY DRY - 2AMPe30VDC .5AM114I20VAC L SAME AS CKT 1 (ONLY ON -072) TO NEXT SIGA DEVICE, OR, IF LAST DEVICE, NO CONN. TO 'OUT' PINS. TYPICAL EST SIGNATURE SERIES (SIGA) DEVICE WIRING DETAIL NAC + NAC GENESIS SERIES HORN/STROBE OR STROBE ONLY O END OF LINE RESISTOR SEE CUT 9KETS MR VALVE GENESIS SERIES HORN/STROBE 011 STROBE ONLY O 'I'YPICATI STROBE WIRING DIAGRAM z 0 l J O z 0 z OUTPUT OR RESULT qP oL otit, s o '9n 00 oozy ttis� t.r, o I'D9 �r C1 q2 -q� 1:, JP �/- o o`5, 2 oJ' oP F2 Oit' o B AJ' t 9` �i O ® ! �G '9 9fo `o 9 h 20 s P 0 �! P s 2 u' G P ( P cI 2 O 22 S G2 �oTo1?, SIAOy si000 n P O C2o 20 20 2 yT O q 0 �90(oo rPT o 4 Dia 0oP 9l P2o P2o P2o Plc' SMOKE DETECTOR. ALARM X X X X HEAT DETECTOR ALARM X X X X PULL STATION ALARM X X X X WATERFLOW ALARM X X X X DUCT SMOKE DETECTOR x x x X VALVE TAMPER X X X ABNORMAL DEVICE/CIRCUIT X X )� SYSTEM OPERATIO SCALE NONE ID NS MATRIX OCT -62005 Tukwila Fire �zyciC% 3,s A ISSUED FOR APPROVAL z L4 10 In •-" 10 0 ISCALE. 1/8" 0 APPROVAL, E I DESIGNER, J, (n IDRAFTSMAN J, Strength and Wisdom Over Two Decades of Service SHEET NUMBER FF252013- SHEET 1 OF 1 REF 0 ,GYP. BD. CLO. IT 10'-6" ` G4A GSAE A G-. A G AE G- A G -A EXISTING ELEC. ROOM N.LC. F-1 41P. BD_ CLI_ N1. ATT. 0._6" G1P.BLI. CLG. Hf. 'iii 10'--C" 0.6.1. 6116, FD. 164. 610. _n ,T-6` 6.1.6. j) 0D. ( P-1 P. BD- 6060[1 A.F.F. 1 ' D LD I {--H� J -t-(1)- i I 4 64P. FD. 4 I 1?_' -0" 1 G4 -171 04 3,06 44, 0 t• P - 1 GIP. BD 12' AFL - D1 I I� D P c-+ • E -lo 0 FIRST FLOOR PLAN SCALE: 1/1i=1' -o" 4", GENERAL NOTES 1. = EXISTING 1" PLUGGED OUTLET. ( 2. DASHED LINES INDICATE EXISTING PIPING. 3. SEE DETAIL FOR TYPICAL HANGER. FILE FIG. 105 COACH SCREW HANGER FIG. 200 ADJUSTABLE COACH SCREW ROD AND RING ACCEPTED RP Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire - Prevention Bureau for co tf3nmonce with current city standards. Acceptance is subeot to errors and omissions which do not authorize violations of adopted to ndards and o dinanc s. The reoponsiblity for the o bequacy of design rests totally with the designer. Additions, dat0Gons or revisions w these drawings after I this date will void ti+is,accepta5ce and will require a I resubmittal of revised drawings for subsequent epproval. RING HANGER - - - Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: S-713//05.- By: L-' 0 lagLI TUKWILA FIRE DEPAHhiv1 .6I Please call: 575-4407 and give this job No. (7S'-, S- 16 and exact address for shut. down or restoration approv�.. EXISTING PIPING EXISTING 1" OUTLET VARIES TY RICA 3 Io DETAIL SCOPE OF WORK EXTEND FIRE SPRINKLER SHELL SYSTEM TO NEW BUILD OUT. RECEI AUG 31' Tukv>yj ONNINVYEC VI CI \IITYI VA3 ED 005 ire PAID AUG 312005 Tukwila Fire ,Q .2ga38 Gkir g5 HANGER LEGEND A "U" HOOK B COACH SCREW ROD BM. CLAMP W/ 8"STRAP E EYELET - F FLUSH SHELL G CEILING FLANGE H SIDE BEAM BRACKET K SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T U V W X Y Z STATE CERTIFICATION SPRINKLER LEGEND SPRINKLER ORIFICE SIZES AND TYPE 2 s 3 i6 7 7 2 SPRAY 16 0 O O 1/2" O 1" 3217 SPRAY L7 3/4" 1" 2 1/2' 411 DRY TYPE 0 0 2 - WAY EARTHQUAKE BRACE 4 - WAY EARTHQUAKE BRACE TEMP RAT NG STCTURE TO CENTER LINRUE OF PIPE IN INCHES FITTING LEGEND P PIPE -0 -LET 0 165° O 212° 266° 350° soo° CO 1/2" V 1" 1/2" 1 /2" 1/2" PLAIN END FIT FITTING APPROVAL REQUIRED 51( GROOVED SHAPED NIPPLE TUKWILA FIRE DEPT. TSN THREADED SHAPED NIPPLE SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFIC0 HEAD SIZE FINISH ESCUTCH FINISH TEMP QTY • RELIABLE FI FR/F2 O.R. SSP 7 CHROME CHROME 155 114 TOTAL 114 QUALITY CONTROL BY - DATE APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFP* PAMPHLET N0. 13. APPLICABLE EDITION 4. PIPE HANGERS AND METHOD OF HANGING TO 8E IN ACCORDANCE WITH NFPA PAMPHLET N0. 13, APPLICABLE EDITION. 5. PIPING SHALL 8E IN ACCORDANCE WITH NFPA PAMPHLET N0. 13, APPLICABLE EDITION 6. JOINING OF PIPE AND FITTINGS. THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET N0. 13, APPLICABLE EDITION. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. All WIRING OF ELECTRICAL DEVICES (10 REQUIRED) TO BE PROVIDED BY OTHERS 7. B. 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO RE PROVIDED BY OTHERS DESIGN CRITERIA 1. DESIGN PER NFPA 13 (2002 EDITION), ORDINARY HAZARD. PIPE NOTES 1. ALL NEW THREADED PIPING TO BE SCH-40. REVISIONS NO DATE BY DESCRIPTION CONTRACT WITH: J.E. JOHN COOK CONSTRUCTION 1701 SE COLUMBIA RIVER DR. VANCOUVER, WA 98661 - - JON COOK PROJECT NAME: ULTA *191 PARKWAY SUPERCENTER 17320 SOUTHCENTER PARKWAY TUKWILA, WA VIC 360-910-0933 PFIRE PROTECTION u ATRIOT 2707 70TH AVENUE EAST TACOMA, WA 98424 - DESIGNER DATE CLINT CARR SHEET 8-30-05 JOB NO. 12-8884 1 OF 1 PATRIFP099CF ti TELFP -Pt' (253) 926-2290 FAX 253 922-6150 742 S11 FT. TRAIN/NG: ROOM DM OFFICE 10 104 rr* NEW GYP. BD. 9%0" NEW ACT -2 V-0" EXISTING GYP. BD. ±11-11 1/2" NEW ACT -3 ±10-11" .58 SO. FT I OFFICE I I 03 , 17 SO, FT. COAT CLOSET 102 6305C FT. SALON NEW ACT -2 11'-0" E. FEZ0., FT. MEDIA CLOSET NEW ACT -2 1i-0" 2D Sa FT. CLOSET NEW ACT- iF-11 1/2" NEW ACT -1 22-1/2/2. FT. CORRIDOR 108 123 Sr). FT. WOMENS NEW ACT -3 ±8.-11 1/2" NEW ACT -2 9'-0" 81 So FT, MENS SQ FT. STOCK CLOSET NEW ACT -1 1110" ITA SHAMPOO! DRYING NEW ACT -2 ±11'-0" 9:-.0 FL STAGING 3 77 SO FF. FIRE RISER 4 7 1 i , 1 _I/Jr,...) 1-'-, i >151:1P' EXISTBIG T-' IRE ISPRIIIKT.E P. FL [ .. koom I - - I ' I ,- d' i ,-- -1(i, E -- -,--d--1 1 (?-3FIE RE, (4t,i iliti . 1, , 1 , , 1, 1 1 , I-4 .1.(t. ,.1^ r i 1 C. -, I 1 ii,T6J1 1 1: / i I- - ---- I••-1 1 - - - 1 -- 1'-1 '-.1 1 i "r -I 1 - `1, 1- 1 I VI(I_ r, 1 I e.1 1 -1- 1 , st , ,1 -1 , , ___, , 1.... ,, i,...,*1......., ..J„... A". , . , 4 i in 0)5/ 0 (,,i)116 _LL ;4E -- I , 1. I V NEW ACT - ±10' -11 1/2" 1113 SI FT CORRIDOR 101 (2 • 2/235/2.22. SALES 100 0 1)RE 0E rrfjlj 0 0 r' RE k)RE ., 11- 1 T. 001 0 9F1:21299999K2W1,9111LITTT,Pa.1-19119,9W1/20 Dt9991/12:,to.Tiord.:•;,-Iirrd--;Enra r'RE 0 0 0 0 0 4)RE EXISTING GYP. BD. v-111/2^ 11 II II WIW II. -- 1--•--1 *-.1 r I 0 0 0 I° 1 1 1 1 1 ,;,".' 4* '- -'?' •.,,,47-*.T.........1,T .,9,1•T''. 4:^ "TT" 'TTTT'T la I .--- (S) I 1 1 0 o 1 i 0 10 10 '7') ..'•!-')RE 0 0 0 o 0 •1t;;Tt1:•TrstInt'SgLSZZats::t-t-Tt`1.,•i's11.1`,S;f1-;TETITZ-TV-TE;;;;2,72;tSztss:;T!TSTLI__. Rli FIRE SPRINKLER TI REMODEL PLAN -10 0 10 20 40 SCALE: 1/8" = 11250.24. VESTIBULE f 116 0 0 0 NEW GYP. ED. 11-0' *RE REMODEL LEGEND EXISTING SPRINKLER PIPE NEW SPRINKLER PIPE (#,‘P PLUG EXIST. QR 155' SEMI-REC SSP SPRINKLER 3 41) RE fi17)11TEWQ&IR5''SEOIN-CREWESID ;'siS,PDNONIE<R140 BE REPLACED 83 O RN RELOCATE NEW 0IT 155° CONCEALED SSP SPRINKLER A ADD NEW QR 155' CONCEALED SSP SPRINKLER 10 29 115 x 1/2" REDUCING COUPLING [37.J9maj DIA CUP 4/,MAX. - COVER ADJUSTMENT 1/4" [6.35mmj AM TO CEILING 1" (25.4r7,mj MAX. DROPPED DEFLECTOR TO CEILING NEW ACT -1 V-0" NEW ACT -3 ±10-11 1/2' EXISTING GYP. BD. ±10'-5" 0 [42.59mArg HOLE IN CEILING 3- 1/16' [77.72mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION SPRINKLER RING RELIABLE RA3415 G5 QR SSP CONCEALED- NTS SAMMY SIDEWINDER- NTS SAMMY SUPERSCREW- NTS SCOPE OF WORK: 1. ADD & RELOCATE REQUIRED SPRINKLERS FOR NEW LIGHTS & WALL LOCATIONS. 2. WET SYSTEMS TO BE DESIGNED PER NFPA #13. *SPRINKLERS SHALL BE SPACED FOR ORDINARY HAZARD OCCUPANCY. *USE 130 SQ. FT. MAX FOR SPRINKLER SPACING IN ALL AREAS. 3. PLAN SUBMITTAL TO & APPROVAL BY CITY OF TUKWILA. FILE COPY 4. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY ARCHER CONSTRUCTION, INC. 5. TESTING PER NFPA #13 & CITY OF TUKWILA. 71'77.7D 4s -t 6. CRITERIA BASED ON NFPA #13 AND CITY OF TUKWILA CODES. 7. ALL NEW WALLS TO BE 6" ABOVE GRID OR TO FACE OF FINISH CELILING. vItc:rout, Comments 8. NEW HYDRAULIC CALCULATION NOT REQUIRED. As Noted in Re2 Psr 4tt6;ct1t.q Letter EXCLUSIONS: 1. TAXES OF ANY TYPE. 2. ELECTRICAL OF ANY TYPE. 3. UNDERGROUND PIPING OF ANY TYPE 4. STRUCTURAL VERIFICATION & ABATEMENT OF ANY TYPE. 5. LABELING, PREP FOR & PRIMING OR PAINTING OF ANY TYPE. 6. RELOCATION OF PIPE FOR WORK OF OTHER TRADES. 7. FIXING ANY AND ALL LEAKS OUTSIDE OUR AREA OF WORK. I, 8. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED ALA MlNIMUIVLOEAO°F r2^. ty 1 1-10 1-61(' 4/s Fire currerrt ary _Cysor etTor,s and nt:ii-anerti :Tit adopted T ;--esecrsirdtty ftv the Cr -.G dea:;,3rer, ; =T:-,; • ''-'_ MeSe after T T7T req,..;]se a -titd - " terit approval. = T 7,Ela InspeCOOT1 by (BY OTHERS) IN ORDER TO PREVENT THE PIPE FROM FREEZING. .11i4L'. ,ALft-T FITTER NOTES: /5--S-038 e2oct: ;2:.:V:oss for shut - 1. HANGERS: JSY•01,11 r;1' * PIPE HANGERS TO BE SAMMY SUPERSCREW AND/OR SIDEWINDER FOR COMBUSTIBLE WOOD CONSTRUCTION * PROVIDE HANGERS ON ALL NEW ARM OVERS, EXCEEDING 1* -0" OR GREATER IN LEN. 2. CEILING HTS ARE AS NOTED. 3. EXISTING UPRIGHT PROTECTION TO REMAIN THROUGHOUT. 4. SPRINKLERS IN GRID CEILINGS ARE REQUIRED TO BE CENTER OF TILE. 5. NEW PIPING TO BE SCH 40 BLACK PIPE, JOINED W/ DI FITTINGS. 6. ALL EXISTING QR 155° SEMI-REC SPRINKLERS ARE TO BE REPLACED WITH NEW QR 155° CONCEALED PENDS. TYPICAL NTS ARM OVER DETAIL L0 28,135.st ttit.I • 99sT ---«Arnerics Best s1 "1 -b, -84th e4Oady Works store HANGER SPACING LEGEND PER NFPA 13 TABLE 9.2.2.1 2010 EDITION 0 I 111,4 - - EMI 0 1Plii WI Vim NV MEI NEW ACT -2 ±11'-0" 9:-.0 FL STAGING 3 77 SO FF. FIRE RISER 4 7 1 i , 1 _I/Jr,...) 1-'-, i >151:1P' EXISTBIG T-' IRE ISPRIIIKT.E P. FL [ .. koom I - - I ' I ,- d' i ,-- -1(i, E -- -,--d--1 1 (?-3FIE RE, (4t,i iliti . 1, , 1 , , 1, 1 1 , I-4 .1.(t. ,.1^ r i 1 C. -, I 1 ii,T6J1 1 1: / i I- - ---- I••-1 1 - - - 1 -- 1'-1 '-.1 1 i "r -I 1 - `1, 1- 1 I VI(I_ r, 1 I e.1 1 -1- 1 , st , ,1 -1 , , ___, , 1.... ,, i,...,*1......., ..J„... A". , . , 4 i in 0)5/ 0 (,,i)116 _LL ;4E -- I , 1. I V NEW ACT - ±10' -11 1/2" 1113 SI FT CORRIDOR 101 (2 • 2/235/2.22. SALES 100 0 1)RE 0E rrfjlj 0 0 r' RE k)RE ., 11- 1 T. 001 0 9F1:21299999K2W1,9111LITTT,Pa.1-19119,9W1/20 Dt9991/12:,to.Tiord.:•;,-Iirrd--;Enra r'RE 0 0 0 0 0 4)RE EXISTING GYP. BD. v-111/2^ 11 II II WIW II. -- 1--•--1 *-.1 r I 0 0 0 I° 1 1 1 1 1 ,;,".' 4* '- -'?' •.,,,47-*.T.........1,T .,9,1•T''. 4:^ "TT" 'TTTT'T la I .--- (S) I 1 1 0 o 1 i 0 10 10 '7') ..'•!-')RE 0 0 0 o 0 •1t;;Tt1:•TrstInt'SgLSZZats::t-t-Tt`1.,•i's11.1`,S;f1-;TETITZ-TV-TE;;;;2,72;tSztss:;T!TSTLI__. Rli FIRE SPRINKLER TI REMODEL PLAN -10 0 10 20 40 SCALE: 1/8" = 11250.24. VESTIBULE f 116 0 0 0 NEW GYP. ED. 11-0' *RE REMODEL LEGEND EXISTING SPRINKLER PIPE NEW SPRINKLER PIPE (#,‘P PLUG EXIST. QR 155' SEMI-REC SSP SPRINKLER 3 41) RE fi17)11TEWQ&IR5''SEOIN-CREWESID ;'siS,PDNONIE<R140 BE REPLACED 83 O RN RELOCATE NEW 0IT 155° CONCEALED SSP SPRINKLER A ADD NEW QR 155' CONCEALED SSP SPRINKLER 10 29 115 x 1/2" REDUCING COUPLING [37.J9maj DIA CUP 4/,MAX. - COVER ADJUSTMENT 1/4" [6.35mmj AM TO CEILING 1" (25.4r7,mj MAX. DROPPED DEFLECTOR TO CEILING NEW ACT -1 V-0" NEW ACT -3 ±10-11 1/2' EXISTING GYP. BD. ±10'-5" 0 [42.59mArg HOLE IN CEILING 3- 1/16' [77.72mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION SPRINKLER RING RELIABLE RA3415 G5 QR SSP CONCEALED- NTS SAMMY SIDEWINDER- NTS SAMMY SUPERSCREW- NTS SCOPE OF WORK: 1. ADD & RELOCATE REQUIRED SPRINKLERS FOR NEW LIGHTS & WALL LOCATIONS. 2. WET SYSTEMS TO BE DESIGNED PER NFPA #13. *SPRINKLERS SHALL BE SPACED FOR ORDINARY HAZARD OCCUPANCY. *USE 130 SQ. FT. MAX FOR SPRINKLER SPACING IN ALL AREAS. 3. PLAN SUBMITTAL TO & APPROVAL BY CITY OF TUKWILA. FILE COPY 4. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY ARCHER CONSTRUCTION, INC. 5. TESTING PER NFPA #13 & CITY OF TUKWILA. 71'77.7D 4s -t 6. CRITERIA BASED ON NFPA #13 AND CITY OF TUKWILA CODES. 7. ALL NEW WALLS TO BE 6" ABOVE GRID OR TO FACE OF FINISH CELILING. vItc:rout, Comments 8. NEW HYDRAULIC CALCULATION NOT REQUIRED. As Noted in Re2 Psr 4tt6;ct1t.q Letter EXCLUSIONS: 1. TAXES OF ANY TYPE. 2. ELECTRICAL OF ANY TYPE. 3. UNDERGROUND PIPING OF ANY TYPE 4. STRUCTURAL VERIFICATION & ABATEMENT OF ANY TYPE. 5. LABELING, PREP FOR & PRIMING OR PAINTING OF ANY TYPE. 6. RELOCATION OF PIPE FOR WORK OF OTHER TRADES. 7. FIXING ANY AND ALL LEAKS OUTSIDE OUR AREA OF WORK. I, 8. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED ALA MlNIMUIVLOEAO°F r2^. ty 1 1-10 1-61(' 4/s Fire currerrt ary _Cysor etTor,s and nt:ii-anerti :Tit adopted T ;--esecrsirdtty ftv the Cr -.G dea:;,3rer, ; =T:-,; • ''-'_ MeSe after T T7T req,..;]se a -titd - " terit approval. = T 7,Ela InspeCOOT1 by (BY OTHERS) IN ORDER TO PREVENT THE PIPE FROM FREEZING. .11i4L'. ,ALft-T FITTER NOTES: /5--S-038 e2oct: ;2:.:V:oss for shut - 1. HANGERS: JSY•01,11 r;1' * PIPE HANGERS TO BE SAMMY SUPERSCREW AND/OR SIDEWINDER FOR COMBUSTIBLE WOOD CONSTRUCTION * PROVIDE HANGERS ON ALL NEW ARM OVERS, EXCEEDING 1* -0" OR GREATER IN LEN. 2. CEILING HTS ARE AS NOTED. 3. EXISTING UPRIGHT PROTECTION TO REMAIN THROUGHOUT. 4. SPRINKLERS IN GRID CEILINGS ARE REQUIRED TO BE CENTER OF TILE. 5. NEW PIPING TO BE SCH 40 BLACK PIPE, JOINED W/ DI FITTINGS. 6. ALL EXISTING QR 155° SEMI-REC SPRINKLERS ARE TO BE REPLACED WITH NEW QR 155° CONCEALED PENDS. TYPICAL NTS ARM OVER DETAIL L0 28,135.st ttit.I • 99sT ---«Arnerics Best s1 "1 -b, -84th e4Oady Works store HANGER SPACING LEGEND PER NFPA 13 TABLE 9.2.2.1 2010 EDITION NOMINAL PIPE SIZE 04.) 3/4" 1" 1 1/41 1/2' 2" 2 1/2" 3" 4" 6" 8" STEEL PIPE SCH 40, SCH 10, DF, EF N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 THREADED LIGHTWALL N/A 12-0 12-0 12-0 12-0 12-0 KA N/A N/A N/A COPPEP 8-0 8-0 10-0 10-0 12-0 12-0 12-0 15-0 15-0 15-0 CPVC i 5-6 6-0 6-6 7-0 8-0 9-0 10-0 N/A • N/A N/A WHERE STATIC OR OPERATING PRESSURES EXCEED 100 PSI HANGERS SHALL BE PER NEPA 13 9.2.3.5.2.1 2010 EDITION 431.114,AVV, 19,24961 T ; Vil$W1V$ 37,114-f ZT44i Mali 201959 ' I 'Sidi:id/TS The Lemongrnss iiiittst • Eiar:L& ',C4i..ItiS-t-t-.1neGrafraetit I . • • , " fla.srGegand Lcum,,t,ItAT .77/ Mo7/22 n icip. 4 $i Pcnton Ss-st) rukwo I S tarireSi,o. 2 2":1'; , ti I HITO - ot, W8sifixtdSc.nhcerm . 501.1111%¢1:11;1PkWy* IT ac I.. ULTA KEY PLAN SCALE: N.T.S. 30,TS, eitotla) S 160i St I , r T ; = - cp 1.1:0 WASHINGTON STATE CERTIFICATE OF COMPETENCY' FIRE PROTECTION SPRINKREE SYSTEMS SI SE ::4111S1 TheOdOre M. Queen Isom& - 4930-025-C Level arN,N, Archer Construction, Inc. ARCRIE112190R _17 _ WSCL#: ARCHEI*219OR VICINITY MAP SCALE: N.T.S. PERMIT PLAN - NOT FOR CONSTRUCTION AS REVISIONS HANGERS HYDRAULIC DESIGN INFORMATION DATE DESCRIPTION BY DENSITY OP NISEI. ET. ttlaj,1.2. 111A-RIUMPL: TT, HYDRAULIC DESIGN INFORMATION ,10At. ODE 1.18211ED INI*"' • MUM frsgur AB AFF BOB BOO BOJ BOP BOT CTS FO IFOW OFOW NAS ONO BREVIATIONS WATERFLOW INFORMATION SPRINKLER SYMBOLS ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS MESS NOTED OTHERWISE RIGID COUPLING 11EvRIF col i:Nr STATIC XX PSI SYM MAKE ODEL SIN TYPE FINISH K -FAC. THREAD ORIFICE TEMP CANOPY QTY RESIDUAL XX PSI _9 GPM FLOWING XXXX GPM RELIABLE 735 RA3415 CONCEALED BRS K=.5.6 1/2" 1/2" 155' WHT 122 DATE & TIME XX/ - PER: LOCATION: CONSTRUCTION, INC ULTA #191 17320 S. CENTER PARKWAY TUKWILA, WA 98188 FIRE SPRINKLER T.I. PIPING PLAN PERMIT NO: - JOB NO: S15-39 AUTHORITY: CITY OF TUKWILA NOTES: TOTAL PROJECT SPRINKLERS = 122 TOTAL SPRINKLERS THIS SHEET 122 FIRE PROTECTION DIVISION 7855 S 206TH STREET, KENT, WA 98032 PHONE 253-872-7222 FAX 253-872-7277 CONTRACTOR: THREE RIVERS CONSTRUCTION SUPT: GARRETT 530.310.0030 PM: JIM 775.825.5248 DESIGNER: TRAVIS TORNGA SCALE: 1/81 11-0. DATE: 1200415 REVISED 11 FP 1 OF 1 NorrLo 3/12/15 FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON TUKWILA FIRE DEPARTMENT call 206-573-4407 and Ci"2 tf"S Fro P e.r li t (� o. I S -F -os =.nd E::43t roc tis for shut - ,own or rz.E.toration approval Acro, TED Fkr`opy r SHEET # SHEET INDEX FA -01 SYSTEM INFORMATION & CALCULATIONS FA -02 FIRE ALARM PLAN SHEET INDEX QUANTITY 4 E E E E E E SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT VN FIRE ALARM HORN STROBE (NEW) EGC-HDVM EST 4S BOX CEILING FACP BPS E E FIRE ALARM CONTROL PANEL (EXISTING) EXISTING EXISTING EXISTING 66" A.F.F. TO TOP REMOTE BOOSTER POWER SUPPLY (EXISTING) SK -5395 SILENT KNIGHT EXISTING 66" A.F.F. TO TOP _ ,SMOKE DETECTOR LE (EXISTING) EXISTING EXISTNG - EXISTING CEILING 1 E 6E MANUAL PULL STATION (EXISTING) EXISTING EXISTNG EXISTING 48" A.F.F. TO CENTER FIRE ALARM HORN STROBE (EXISTING) EGC-HDVM EST EXISTING CEILING FIRE ALARM HORN STROBE (EXISTING) EGG -VM EST EXISTING CEILING END -OF -LINE RESISTOR VERIFY LOCATION IN FIELD EX EXISTING DEVICE N/A N/A N/A N/A A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A SYMBOLS LEGEND WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LOOP TWISTED SHIELDED PAIR #16 FPLP S STROBE CIRCUIT TWO #14 FPLP I INITIATION CIRCUIT TWO #16 FPLP CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE TWO 600V #12 AWG THHN/THWN TWO 600V #14 AWG THHN/THWN TWISTED TWO CONDUCTOR 300V #18 AWG FPL TW CABLE CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA CONDUIT SIZE MAXIMUM F 1/2" .12 SQUARE 3/4" .21 SQUARE 1" .34 SQUARE 1-1/4" .60 SQUARE 1-1/2" .82 SQUARE 2" 1.34 SQUARE DIMENSIONS ; AREA .244 O.D. i .0467 .210 0.D. .0346 .156 0.D. .0191 CONDUIT FROM THE TABLE FILL DIMENSION FROM OF THE WIRE. LL NCH NCH NCH NCH NCH NCH TO EXISTING SK -5395 REMOTE BOOSTER POWER SUPPLY CEILING TILE + + IP 41 HORN STROBE HORN STROBE (o TYPICAL NAC CIRCUIT WIRING DETAIL /iiiiiiiiillo SUPPORT BRIDGE 4S BOX HARD LID CEILING CEILING HORN/STROBE / OR STROBE ONLY HORN STROBE/STROBE MOUNTING DETAIL (DROP CEILING) STROBE EOL y 1 STROBE SUPPORT BRIDGE 4S BOX CEILING HORN/STROBE OR STROBE ONLY HORN STROBE/STROBE MOUNTING DETAIL (HARD LID) 1 Without Comments ❑ As in 4 o Per TheNoteo AttaRecn ed Letter e N s have been reviewed by The Tukwila Fire ervon Bureau for conformance 11th current Qty res. Acceptance is subject to errors and s;i^n=_ which do not authorize violations of adopted and ordinances. The responsibility for the -;vary of design rests totally witri tte designer. Jitions, deletions or revisions to these drawings after ,is date will void this acceptance and will require a ubmlttai of revised drawings for subsequent approva'. 'trial acceptance Is subject to field test and Inspection by rhe Tukwila Fire Prevention Bureau. Jare %- By. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must bb presented to the Inspector prior to cornet:: cernent of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing A B C D E F G H I J K FIRE ALARM BOOSTER Project: ULTA BEAUTY Panel: EXISTING SK -5395 REMOTE Date: April 14, 2015 Mod tule/Device POWER Qty SUPPLY BOOSTER Standby (mA) BATTERY POWER SUPPLY Total Standby (mA) CALCULATION Alarm (mA) Total Alarm (mA) Power Module 1 75 75 0 205 205 0 TOTAL FIRE ALARM POWER SUPPLY 75 205 Atodliary Device Current 0 0 Notification Appliance Load (Max Total ( mA) 0 4848 2daaaa -Total(A)7-____75-Total(B)=_ _5053 CALCULATION Total current ratings of all devices in system (line A + line B + line C) 75 5053 Total current ratings converted to amperes (line D x .001) 0.075 5.053 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F . Total Standby AH 1.8 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.4209149 Add lines G and 1 Total Standby and Alarm AH 2.2209149 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 2.66509788 RECOMMNEDED MINIMUM BATTERY SIZE 12VDC 7.0 AMP -HR Notification Appliance Circuit Detail PROJECT: UL1R BEAUTY Panel: EXISTING SK -5395 BOOSTER POWER SUPPLY Wire Resistance 2.58 Date: April 14, 2015 CURRENT TOTAL- 4848.00 EGCF-HDVM @15cd 80 EGCF-H0VM@30ct1; 108 EGCF-HDVM@75cd _185 _ EGC HDVM@95cd. .,212- - EGC-VM @15cd _ 109 EGC-VM @30cd _ 151 1500 TOTAL mA= 24.00 1500 Total Wire Resistance (R) Total Device Load, Amps (I) Voltage Drop ( E ) EOL Voltage - (WL • 2 ) • (R/ft) (Total Cct Load)__„ (E=I•R) 24-E) ( 0.00 ,1.50 0.00 24.00 EGCF-HDVM @15cd 80 '.'EGCF-HDVM@30cd'- __'-- ..108 EGCF-HDVM ©75cd 185 - EGC(`-HDVM @95cd ' 212 EGC-VM @15cd 109 EGC-VM @30cd r 151 DEVICES 1500 TOTAL mA= Total Wire Resistance ( R ) Tota Device Load, Amps(1) Volt a Drop ( E ) EOL oitage 4.00 1500 0.00 24.00 EGCF-HDVM @15cd 80 EGCI -HDVM @30cd . ,'f 108 EGCF-HDVM @75cd 185 EGCIF-HDVM C95cd '-� 212 ... �. EGC VM @15cd 109 EGC VM @30cd - 451 DEVICES 0 TOTAL mA= ,Total'Wire Resistance (R ) _Tota( Device Load, Amps (I) . .. Voltage Drop ( E ) EOLltoltage 3 EGCF-HDVM @15cd 80 EGC-HDVM @3ocd 108 EGCF-HDVM @75cd 185 2400 (WL •2)• (Rift) .,-(Total Cot Loa (E= I * R) 24-E) 1500 0.00 t50 0.00 24,00 EG- _ 0 l EGGVM @30cd 151 , DEVICES 4 Fy TOTAL mA= 348 Total Wire Resistance (R) Total Device Load, Amps (i) Voltage Drop (E ) _ EOL Voltage - - 2349 348 ( WL • 2 ) • (R/ft) 1.48 (Total Cct Load) , ,,. -0.35 (E= I • R) - 0.51 24 - E) -1 23.49 ap z O C7 z_ 3 IST AVE. SO., SEATTLE, W FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS [REV. BY: 2 0 DESCRIPTION [ OP DRAWINGS DATE 04/14/15 2daaaa 0 cococr,00a). �Orrt Z_ wu) Q, <-- c 0 W IECO C>12 W H CC o- (/)LUQQ CC LL W CC F - Q Z � W (i) �CALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: B. VEZANNI DATE: 04/14/15 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 12288-1,1 WIRE DESIGNATION TYPICAL WIRING AND MOUNTING DETAILS CALCULATIONS Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA -01 62 SQ. FT. MEDIA CLOSET 106 RESTROOM EAS SECURITY WALL MOUNTED DEVICE 28 SQ. FT. 224 SO. FT CLOSET CORRIDOR 107 108 1E3SQ.FT. 81 SQ FT. WOMENS MENS 109 110 16 50 FT. STOCK CLOSET 111 329 S0 FT. SHAMPOO/ DRYING 112 FLAGNOTES: RELOCATE EXISTING MANUAL PULL DSTATION TO NEW FRONT ENTRY DOOR. >EXISTING CEILING HORN STROBE TO REMAIN. DOORS ARE WELDED SHUT. 931 SO. FT. STAGING 113 7 SO. FT. FIRE RISER 13 • MING EXIST NG ELEC. ROOM N. I. C. Q. Fr. OFFICE 104 RMAL.OGICA as 6' 144rcd 6' 2S PRESTIGE SKIN Pur MtnTra?: An oz Pao SOFT. ALON ALON HAIRCARE POp Her µ,* Nair Aaces3 4' $tp/Aaa 4.Exten 4' Fcahiorg4' STYLING TOOLS 3 2 N NEW MCLG .917/0 X47 Ms X -a7 oP BENEFIT ALE 100 trait 6ecny 9 6COLOR COSMETICS 116 SO. FT. CORRIDOR 116 SQ. FT. VESTIBULE 6 UL,A Co Lip Eolr.ttana EC N6EY MASS `TI earaWneras FIRE ALARM PLAN SCALE: 1/8" = 110" 742 SQ. FT. TRAINING ROOM 62 SO. FT. MEDIA CLOSET 106 28 SQ. FT. 224 SQ. FT. CLOSET CORRIDOR 163 SQ. FT. WOMENS 81 SQ. FT. MENS 16 SO. FT. 329 S0. FT. STOCK SHAMPOO/ 178s0.Fr. CLOSET DRYING SKIN CARE 991 SO. FT. STAGING 77 SQ. FT. FIRE RISER 13 63 SQ. FT. DM OFFICE 63 SQ. FT. OFFICE 1680. FT. COAT CLOSET VS SQ. FT. SALON 'q mak zei. mom 1W NSI.. lok red witim art, WSk Nala/AletAl 1CZ4i441 ‘41L*1 EXIST NG ELEC. ROOM N.I.. 41,1csAtiOMPFAMIR mirrzi©►2>'.mrar. ,r, 1 .470*- irairtit:AMP;11;61Wil!worror 44. II611111•11©1.1111// rAili 111 I� Ill III 1/I1 um :'911 ps 116 SO. FT. CORRIDOR "Mil RE291111EMII N.17W gamoiffeamoniatammiL 0411 til � W�11►—��1��iC. 8,328 sa FT. SALES A! zie PHASING PLAN SCALE: 1/8", = 1'0" 118 SQ. FT. VESTIBULE Proprietary and Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved 4 c Wz O LD z_ cn uJ J F— Q 144 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: (9 M .................. DESCRIPTION SHOP DRAWINGS w N CD a O co co o 0 z 0 ..1— T— 0 (5)Z_ z_ O 0 0wQ Q�g 2 W LJJ 1.1.1� j z D CO �V Hco - waa L,J. [Li 4CALE: 1/8"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: B. VEZANNI DATE: 04/14/15 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 12288-1,j 1 SHEET FA -02