Loading...
HomeMy WebLinkAboutPP - 17580 SOUTHCENTER PKWY - TORRID - PERMITS AND PLANS17580 SOUTHCENTER PKWY ASSOCIATED PERMITS D19-0142 19-F-179 19-S-173 98-S-158 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 2623049110 Site Address: 17580 Southcenter PKWY, Tukwila, WA Suite Number .21 floor: Tenant Name: Torrid 1st New Tenant? ®- Yes ❑ - No Property Owner's Name: KIMCO Mailing Address: 3333 New Hyde Park RD #100, New Hyde Park, NY 11042 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Derek Deonigi Day Telephone: 206-402-2373 Company Name: Seatronics, Inc. Mailing Address: P.O. Box 1138, Auburn, WA 98071 City State Zip E-mail Address: DerekD@seatronicsfire.com Fax Number: 116383 Contractor's City of Tukwila 0996392 NICET III number: Business License number: Total number of new/relocated devices or sprinkler heads: 14 Valuation of Project (contractor's bid price): $ 19,000.00 Scope of Work (please provide detailed information): Fire Alarm Tenant Improvement. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATERk3HINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNNEE ; OR AUTHORIZED AGENT: CC? 1-`2 2319 Signature: TUKWILA FIREDate: 9/5/19 Robert Grouleff Print Name:Day Telephone: 206-402-2373 8/22/14 TFD FP Form 8 Plan Permit App.doc SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Z (e z304.1 II t Site Address: 17 S ' 0 S o a +k ce n 4e r- Park ,J Ay Suite Number: 2 t Floor: I Tenant Name: TQ 14, , 0 New Tenant? EE- Yes 0 - No Property Owner's Name: 1MC O ee. Ol \}-1/4./ Mailing Address: L(11S ca.c ke c vd.r2 ( % SE city CONTACT PERSON -if there are questions about the submittal. Name: C (' i S r j /e 031 Q, (lc Day Telephone: Company Name: C C OWA , re efo-A-cc ►c3et, 1 NL Mailing Address: r 0 IS b i2 113 ; G City E-mail Address: (rSt% i cin Cr. (b m NICET III number: 617 Q y ®4 &nevac L.1 A le 0063 State Zip 423-3400-6s- Fax Number: Contractor's City of Tukwila (- Business License number. Q0 $ , O 9 4 5 312 Total number of new/relocated devices or sprinkler heads: " re (0c_44 -e.. an S a d d C Ll 6 4-0t-cti) �I4 Qgoga State Zi '-tZsjg/g6 — Valuation of Project (contractor's bid price): $ (0 00 0 Scope of Work (please provide detailed information): (`O(_a.-k-e_ L4 [ E,--eO4 S a. n c eta 1� kc r (\ alt.ni nr f.cou e eref\ I— PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Dr:..+ AT..,..a. -47 °)-1.4?tA t}1 og land PAID AO 27 2019 TUKWILA FIRE Tl.... Tala..T.....a• Date: gfr 7/ yLs 3a) 4S -6I' INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Type RQ.,‘ of Inspection: Audress: ss Contact Person^ y� Suite 1530 Special Instructions: k / Phone No.: VC9 777 -1st/ Approved per applicable codes. Corrections required prior to approval. COMMENTS: ego wort -kc. - S ?(3 ,'1 ailati , Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: a , fi Occupancy Type: r Inspector II Date:/Z/3/ (e Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ---6 Ivo Type of Inspection: F---1 �a/ 07 Address: S #: Suite #:/ 7SFd SC ?AA( Contact Person: Special Instructions: % Phone No.: 2C1 7,Y -- 1-i2 Approved per applicable codes. COMMENTS Y' 4614 Corrections required prior to approval. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: , Occupancy,Tyw: Inspector: \N`,�`A Date:1OR 1-11 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit )s)9— (9/(42, ,q-5-1 13 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT' 206-575-4407 Project;..---7-7'Type p tZR.A'3), Sprinklers: of nspection: 5"00 Ce v - Address:Cont /'7o S� PLuj/ Person: Special Instructions: * / Phone No.: 4. Approved per applicable codes. COMMENTS: Corrections required prior to approval. �rers /mr, (fruiv- V.6 H�w) /436, 44))/e4g /mitt) e teeo OK-- fb c� Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: it '"j Date: 9,, aj�� 9 Hrs.: /. ) $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Iii -F-I? ei SYSTEM DATA SUBMITTAL MANUAL for TORRID 17580 SOUTHCENTER PKWY, #21 FIRE DETECTION AND ALARM SYSTEM Tukwila, WA Prepared by Seatronlcs, Inc. PO Box 1138 Auburn, WA 98071 253-939-6060 SENTRONICS, INC. JOB# 111073 SYSTEM DATA SUBMITTAL MANUAL for TORRID Tukwila, WA FIRE DETECTION AND ALARM SYSTEM TABLE OF CONTENTS SECTION 1 SYSTEM DESCRIPTION SEQUENCE OF OPERATION SECTION 2 SECTION 3 EQUIPMENT DATA SHEETS POWER & BATTERY CALCULATIONS SECTION 4 DRAWINGS Doc. Rev. Lvl. — 0, Rev. Date: 7/2/08 Seatronics, Inc. 1501 15th St. N.W. Ste 101 Auburn, WA 98001 253-939-6060 SECTION 1 SECTION 1 SYSTEM DESCRIPTION SEQUENCE OF OPERATION Seatronics, Inc. 1501 15th St. N.W. Ste 101 Auburn, WA 98001 253-939-6060 Seatronics, Inc. Job: 111073 Torrid Fire Alarm System Submittal Manual GENERAL SCOPE OF WORK: Install notification devices for the purpose of tenant improvement. FIRE ALARM CONTROL PANEL (FACP): Section 1 Page 1 The fire alarm and control panel is an existing Siemens model FC922 micro -processor based multiplex type with an internal operating system that is used to process incoming signals and issue output commands as required by system programming or by manual inputs. The FACP consists of a main control board, annunciator/keypad, analog loop drivers, module card cage, power supply/battery charger and batteries. Visual annunciation is provided by an 80 character, liquid crystal display and alarm, supervisory and trouble status indicator lamps. EVACUATION ALARMS: Notice of building evacuation is provided by combination horns/strobe units. Seatronics, Inc. PO BOX 1138 Auburn, WA 98001 253-939-6060 Seatronics, Inc. Job: 111073 Torrid Fire Alarm System Submittal Manual SYSTEM SEQUENCE OF OPERATION 1. ALARM CONDITIONS: Section 1 Page 2 1.1 ACTIVATION OF ANY SPOT TYPE SMOKE DETECTOR, MANUAL PULL STATION OR WATER FLOW SHALL: a. CAUSE THE ALARM INDICATOR LAMP ON THE FACP TO ILLUMINATE. b. CAUSE THE INTERNAL SOUNDER DEVICE IN THE FACP TO ACTIVATE. c. DISPLAY PROPER MESSAGE ON FACP LCD DISPLAY WITH ALARM POINT LOCATION INFORMATION. d. DISPLAY ALARM POINT LOCATION ON THE REMOTE ANNUNCIATORS. e. CAUSE BUILDING FIRE ALARM STROBES AND HORN/STROBES TO ACTIVATE. f. ACTIVATE THE FACP DIGITAL DIALER/COMMUNICATOR AND TRANSMIT AN ALARM SIGNAL TO THE TYCO CENTRAL STATION MONITORING COMPANY. 2. SUPERVISORY CONDITIONS: 2.1 ACTIVATION OF ANY DUCT DETECTOR OR FIRE SPRINKLER TAMPERS SHALL: a. CAUSE THE SUPERVISORY INDICATOR LAMP ON FACP TO ILLUMINATE. b. CAUSE THE INTERNAL SOUNDER DEVICE IN THE FACP TO ACTIVATE. c. DISPLAY PROPER MESSAGE ON FACP LCD DISPLAY WITH SUPERVISORY POINT LOCATION INFORMATION. d. ACTIVATE THE FACP DIGITAL DIALER/COMMUNICATOR AND TRANSMIT A SUPERVISORY SIGNAL TO THE TYCO CENTRAL STATION MONITORING COMPANY. 5. FAULT / TROUBLE CONDITIONS: 5.1 CONDITIONS IN THE SYSTEM THAT MAY CAUSE FAILURE, OR IMPAIR OPERATION OF THE SYSTEM SHALL CAUSE THE FOLLOWING: a. CAUSE THE TROUBLE INDICATOR LAMP ON THE FACP TO ILLUMINATE. b. CAUSE THE INTERNAL SOUNDER DEVICE IN THE FACP TO ACTIVATE. c. DISPLAY PROPER MESSAGE ON FACP LCD DISPLAY WITH TROUBLE LOCATION INFORMATION. d. DISPLAY TROUBLE POINT LOCATION ON THE REMOTE ANNUNCIATORS e. TRANSMIT A TROUBLE SIGNAL TO CENTURYLINK'S REMOTE MONITORING STATION. f. ACTIVATE THE FACP DIGITAL DIALER/COMMUNICATOR AND TRANSMIT A TROUBLE SIGNAL TO THE CENTRAL STATION MONITORING COMPANY. THE FOLLOWING IS AN ABBREVIATED LIST OF THE TYPES OF FAULTS THAT WILL CAUSE A TROUBLE CONDITION TO REPORT TO THE FACP. a. OPEN, SHORTED OR GROUNDED WIRING ON ANY DETECTION CIRCUIT. b. OPEN, SHORTED OR GROUNDED WIRING ON ANY MANUAL CIRCUIT. c. ANY MISSING OR REMOVED ADDRESSABLE DEVICE SUCH AS SMOKE DETECTORS, POINT MONITORING MODULES OR MANUAL STATIONS. d. OPEN, SHORTED OR GROUNDED WIRING ON ANY NAC (HORN/STROBE) CIRCUIT. e. ACTIVATION OF ANY PANEL "BYPASS" OR "OVERRIDE" FUNCTION. f. CONTROL PANEL STAND-BY BATTERY FAULT. g. LOSS OF PRIMARY 120 VAC POWER TO PANEL FOR MORE THAN 90 SECONDS. h. LOSS OF 24VDC POWER. i. FAILURE OF THE SYSTEM DIALER/COMMUNICATOR TO PROPERLY "CHECK-IN" TO THE CENTRAL STATION MONITORING COMPANY ONCE EVERY 24 HOURS OR LOSS OF EITHER OR BOTH PHONE LINES CONNECTED TO THE DIALER. Seatronics, Inc. PO BOX 1138 Auburn, WA 98001 253-939-6060 SECTION 2 SECTION 2 EQUIPMENT DATA SHEETS Seatronics, Inc. 1501 15'" St. N.W. Ste 101 Auburn, WA 98001 253-939-6060 SIEMENS Data Sheet Fire Safety Products HTRI-Series Intelligent Interface Modules Models HTRI-D, HTRI-R and HTRI-S ARCHITECT AND ENGINEER SPECIFICATIONS • Interfacing and supervising normally open (N.0) or normally closed (N.C) contacts • Integral single -pole, double -throw (SPDT) relay on Model HTRI-R (up to 4 amps) • Dual input on Model HTRI-D, using a single address • Polarity insensitive with SureWireTM technology • Dynamic supervision • Two -wire operation • Multi -color light -emitting diode (LED) indicates system status: ■ GREEN / AMBER / RED • Mounts in a 4 -inch (10.2 cm.) square, 2-1/4" (5.7 cm.) -deep single -gang or double -gang back box • Easy front access to programming port and wiring terminals • Comes with 5"-x- 5" (12.7 -x- 12.7 cm.) faceplate • Electronic address programming is easy and dependable • Device Programmer / Tester programs and verifies address of the device and tests for proper functionality • ®UL Listed & ®ULC Listed; FM, CSFM and NYC Fire Dept. Approved Product Overview The Siemens— Fire Safety HTRI-series Intelligent interface modules are designed to provide the means of interfacing direct shorting devices to the fire -alarm control panel (FACP) loop circuit on up to 50 -point, 252 -point and 504 -point Siemens addressable* FACPs. The HTRI-series modules provide the most advanced method of address programming and supervision on the market—combined with sophisticated control panel communication. Each HTRI-series interface module incorporates a microcomputer chip, and each interface module achieves the state of an 'intelligent device' through its microcomputer -chip technology, combined with its sophisticated, bi-directional communication capabilities with the FACP. Specifications The Siemens Mode HTRI-series intelligent interface modules are available in three (3) types: Model HTRI- D, as well as Models HTRI-S and HTRI-R, which are both designed to monitor a (N.0) or (N.C) dry contact. * Asterisk above denotes product is compatible with Siemens Model FC2005 / FC901 50 -point addressable FACPs, as well as working with Model FC2025, FV2025 FC922, FV922 252 -point addressable FACPs and with Model FC2050, FV2050 / FC924, FV924 504 -point addressable FACPs SIEMENS Industry, Inc. Building Technologies Division The interface module reports the status of the (N.0) or (N.C) contact to the control panel. Model HTRI-S can only monitor and report the status of the contact, while Model HTRI-R incorporates an addressable 'Form C' relay. The Model HTRI-R relay and contact device input are controlled at the same address. For the FACP, the relay and input contact can be controlled as a separate function. The relay is typically used where control or shunting of external equipment is required. The Model HTRI-D is a dual -input module that is designed to supervise and monitor two (2) sets of dry contacts. Model HTRI-D only requires one (1) address, but responds independently to each input. Model HTRI-D is ideal for monitoring a water -flow switch and its respective valve tamper switch. Model HTRI-D flashes twice — once for each address, and Model HTRI-IR LED indicates a change of state in the relay. The microcomputer chip has the capacity of storing - in memory - identification data; as well as key operating -status information. HTRI Series Interface Modules 6304 Specifications (continued) Each Model HTRI device has a multi -color LED that flashes GREEN when operating in Normal; AMBER if unit is in Trouble condition, and RED to indicate a change of state. Field -Device Programmer Siemens— Fire Safety innovative technology allows HTRI-series intelligent interface modules to be programmed via the Device Programming / Test Unit: a compact, portable and menu -driven accessory that makes programming and testing an interface device faster, easier and more dependable than previous methods. The programmer I tester eliminates the need for mechanical addressing mechanisms, such as: program jumpers, DIP switches or rotary dials, since Model DPU electronically sets the HTRI-series interface address into the non-volatile memory of the interface microcomputer -chip. Vibration, corrosion and other conditions that deteriorate mechanical addressing mechanisms are no longer a cause for concern. The HTRI-series is fitted with screw terminals for connection to an addressable circuit, and is fully compatible on the same Siemens FACPs with Siemens Model 'H' -series intelligent detectors; Model 'HMS' -series addressable manual stations, or any other addressable intelligent modules (e.g. — Model HZM or Model HCP). Temperature and Humidity Range Model HTRI-series intelligent interface modules are ®UL Listed. Environmental operating conditions for HTRI-D, HTRI-R and HTRI-S modules are 32°F (0°C) to 120°F (49°C) with a relative humidity of no greater than 93%, non -condensing. Electrical Ratings Current Draw (Active or Standby) 1.3mA Relay Ratings, Model HTRI-R Resistive: 4 Amps, 125 VAC 4 Amps, 30 VDC Electrical Ratings Relay Ratings, Model HTRI-R - (cont.'d) Inductive: 3.5A, 120 VAC (0.6P.F.) 3.0A, 30 VDC (0.6P.F.) 2.0A, 120 VAC (0.4P.F.) 2.0A, 120 VAC (0.35P.F.) 2.0A, 30 VDC (0.35P.F.) Mounting Diagram Models HTRI-S, HTRI-D and HTRI-R mount directly into a 4 -inch (10.2 cm.) square, 2'/4" (5.7 cm.) -deep box back box, or to a user -supplied double -gang back box. A 5" (12.7 cm.) square, off-white faceplate is included with each HTRI-series module. MOUNTING SLOTS FOR 4 -INCH SWITCHBOX HTRI-S/-D/-R MODULE MOUNTING HOLES FOR SWITCHPLATE MOUNTING SLOTS FOR DOUBLEGANG SWITCHBOX Details for Ordering Model NPart umber Description HTRI-R 500-033300 Single Input Module with Relay HTRI-D 500-033360 Dual Input Module HTRI-S 500-033370 Single Input Module Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. SIEMENS Industry, Inc. Building Technologies Division Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (908) 547-6877 URL: www.USA.Siemens.com/FIRE (5D -FS) Printed in U.S.A. Fire Safety 1577 North Service Road East Oakville, Ontlario L6H 0H61Canada Tel: [905] 465-8000 URL: www.Siemens.CA August 2015 Supersedes sheet dated 6/2015 (Rev. 5) SIEMENS Fire Safety HMS Series Intelligent InitiatingDevices Manual Fire Alarm Boxes ENGINEER AND ARCHITECT SPECIFICATIONS HMS -S and HMS -D Intelligent Manual Fire Alarm Boxes for FireFinder XLS Control Panels • Durable Design • Shock and Vibration Resistant • Pull Down Lever Remains Down Until Reset • Custom Microcomputer ChipTechnology • Dynamic Supervision • Polarity Insensitive with SureWireTMTechnology • Reset with Allen Key • No Break Rods Necessary • TwoWire Operation • Surface or Semiflush Installation • DPU Programs and Verifies Device's Address and Tests Device's Functionality • Electronic Address Programming is Easier and More Dependable • Single and Double Action Models Available • ®, Listed, CSFM, FM and NYMEA Submitted FIRE PUSH HERE THEN PULLDOWN HMS -S Single -Action Station SIEMENS HMS -D Dual -Action Station Introduction HMS -S and HMS -D intelligent manual fire alarm boxes provide the markets' most advanced method of address programming and supervision, combined with sophisticated control panel communication. Each HMS manual fire alarm box incorporates custom microcom- puter chip. The microcomputer chip technology, and its sophisticated bi-directional communication capabilities with the control panel, achieves the state of an "Intelli- gent Initiating Device" Description The HMS -S and HMS -D are constructed of durable molded polycarbonate material which is matte finished in red with raised white lettering. The housing accom- modates a "pull-down" lever which, when operated, locks in position indicating the manual fire alarm box has been activated. The pull down lever remains down and locked until the manual fire alarm box is reset. The manual fire alarm box is reset only by opening the hinged housing cover with an alien key and then closing and locking the cover. The HMS -S and HMS -D manual fire alarm boxes operate with FireFinder XLS Series control panels. The manual fire alarm box's microcomputer chip has the capacity of storing, in memory, identification information as well as important operating status information. Siemens BuildingTechnologies Inc., Fire Safety Division innovative technology also allows all HMS Series Intelligent manual fire alarm boxes to be pro- grammed by using the Model DPU Programmer/ Tester. The Programmer/Tester is a compact, portable, menu driven accessory which makes programming and testing a manual fire alarm box device faster, easier and more dependable than previous methods. The DPU eliminates the need for the device's mechanical addressing mechanisms, such as program jumpers, dipswitches or rotary dials because the DPU electroni- cally sets the manual fire alarm box's address into its microcomputer chip, nonvolatile memory. Vibration, corrosion and other conditions which deteriorate mechani- cal addressing mechanisms are no longer a cause for concern. CATALOG NUMBER 6306 The HMS -S and HMS -D are fitted with screw terminals for connection to an addressable circuit. They can be either surface or semiflush mounted. The HMS Series manual fire alarm boxes derive their power, communicate information and receive commands over a single pair of wires. The HMS Series is compatible on the same circuit with all H Series detectors, interfaces or addressable conventional zone modules. Mounting Data Ordering Information Model Description Shipping Lbs. Weight kg. Part Number HMS -S Addressable Manual Fre Alarm Box Single Action 2.0 .90 500-033200 HMS -D Addressable Manual Fre Alarm Box, Double Action 2.5 113 500-033400 SB -SR Surface Mounting Box 1.5 .68 310-019860 LTP ResetTool Package (Contains 2 tools) .5 .23 500-620490 HOUSING HINGED TO NAMEPLATE BACKPLATE --***116. . HOUSING -�� LOCKING • SCREW BACKPLATE \ SURFACE MOUNTING ENCLOSURE 3 in 31/2 in DEEP SWITCH BOX (USER SUPPLIED) Electrical Ratings Current Draw (Active or Standby): 1.5mA NOTICE: The use of other than Fire Safety detectors and bases with Fire Safety equipment will be considered a misapplication of Fire Safety equipment and as such void all warranties either expressed or implied with regard to loss, damage, liabilities and/or service problems. Siemens Building Technologies Fire Safety Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 8/05 Bramptor, Ontario Tel: (973) 593-2600 5M Canada L6T 5E4 FAX: (973) 593-6670 SFS -IG Tel: (905) 799-9937 August 2005 Website: www.sbt.siemens.com/fis Printed in U.S.A FAX: (905) 799-9858 Supersedes sheet dated 1/03 Technical Data TD450049EN Effective November 2016 Supersedes October 2014 HN Series HS Series ST Series Exceder Strobe, Horn Strobe, and Horn Notification Appliances EffeN Powering Business Worldwide Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre -wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre -wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Technical Data TD450049EN Effective November 2016 'eatures Sleek modern aesthetics • Finger slide switches • Voltage test points • Multiple voltages • 3 Audible settings • 90, 95, 99 dB • Industry leading -8 candela settings on 1 device • Wall: 15/1575/30/75/95/110/135/185 • Ceiling: 15/30/60/75/95/115/150/177 • Universal mouting base • Ceiling and wall • Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, 3.5" octal. & 4" octal. (100mm for international customers) Universal mounting base Cie 4 ' >> N M Contact cover Common base for wall and ceiling with 5 mounting options • Voltage test points for quick troubleshooting and easy spot checking (wall models only) 2 EATON www.eaton.com HN Series HS Series ST Series • Environmentally friendly • Low current draw • Up to 9 models now in 1 appliance draw® • 12/24VDC on a single appliance • Easy to remember model numbers ® Patented Note: Please read these specifications and associated installation instruc- tions, before using, specifying, or installing this product. Visit Eaton.com/ massnotification for current installation instructions. General Notes • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range': • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). • Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements • Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Patented Sync Protocol • Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage • Strobes produce 1 flash per second over the "Regulated Voltage" range Compliance • UL 1971, UL 464, ULC, CSFM, FM • ADA/NFPA/ANSI/OSHA • RoHS HN Series HS Series ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current() Regulated Voltage Model Range VDC Technical Data TD450049EN Effective November 2016 24 VDC / 24 FWR 12 VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Current() at Anechoic 99 dBA Regulated Voltage Model Range VDC 24 VDC 12 VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - Regulated Voltage Model Range VDC UL Max Current() at Anechoic 95 dBA 24 VDC 12 VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - Regulated Voltage Model Range VDC UL Max Current() at Anechoic 90 dBA 24 VDC 12 VDC 15 15175 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ,O UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Table 3. Hom Ratings per UL Anechoic Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 Table 4. Specification & Ordering Information Sync w/ DSM or Wheelock Power Model Strobe Candela Supplies 12/24 Mounting VDCW Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X HSW 15/1575/30/75/95/110/135/185 X HSRC 15/30/60/75/95/115/150/177 X HSWC 15/30/60/75/95/115/150/177 X Strobes X UMB® X UMBO X UMBO X UMB® STR 15/1575/30/75/95/110/135/185 X STW 15/1575/30/75/95/110/135/185 X STRC 15/30/60/75/95/115/150/177 X STWC 15/30/60/75/95/115/150/177 X Horn X UMBO X UMB® X UMB® X UMBO HNR X X UMB® HNW X X UMBO HNRC X X UMB HNWC X X UMBO O 12 VDC models feature 15 & 15/75 settings OO UMB = Universal Mounting Base Model Legend HN = Horn R = Red ST = Strobe HS = Horn Strobe C = Ceiling Mount W = White • A = Agent Lettering (strobes only) AL = Alert Lettering (strobes only) N = No Lettering (strobes only) Example 1: STRC = Strobe, Red, Ceiling Mount Example 2: HSR = Horn Strobe, Red, Wall Mount Example 3: HSW = Horn Strobe, White, Wall Mount Example 4: STW-AL = Strobe, White, Wall Mount, Alert Lettering Example: HSR Example: HSWC EATON www.eaton.com 3 Technical Data TD450049EN Effective November 2016 HN Series HS Series ST Series Irchitects and Engineers Specifications e notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) With the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where multi - candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g., ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single -gang, double -gang, 4 -inch square, 3.5 -inch octal, 4 -inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non -synchronized flash -rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. 'gall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS ;fling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. XENIA Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY E:T•N Powering Business Worldwide Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 Eaton com/massnotification © 2016 Eaton All Rights Reserved Printed in USA Publication No. TD450049EN November 2016 Eaton is a registered trademark All ether trademarks are property of tier respective owners SECTION 3 SECTION 3 POWER & BATTERY CALCULATIONS Seatronics, Inc. 1501 15th St. N.W. Ste 101 Auburn, WA 98001 253-939-6060 D Configure Circuits Print Page Wire resistances are based upon an ambient temperature of 72 degrees F. Because of —Global Project values. i Project Name: TORRID Standby Hours: 24 tSILENT i KN IC I-I'I' Project ID: 111073 Alarm Mins: 5 Prepared By: NG Derating Factor: 1.2 5495 Power Expander Calculations Date: 9/4/2019 Voltage Drop Warning Version 02.18.09 Threshold % . 10 Panel ID: 5495 Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location: ELECTRICAL RM Volts: 24 VDC Max Panel Current: 6.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5495 5495 Pwr Module 1 0.075 0.205 NAC #1 5495 Circuit 1 0.000 0.454 #12 Solid 1.59 80 ' 0.25 20.28 NAC #2 5495 Circuit 2 0.000 0.800 #12 Solid 1.59 191 0.61 19.91 NAC #3 5495 Circuit 3 SPARE 0.000 0.000 #12 Solid 1.59 0.00 20.40 NAC #4 5495 Circuit 4 SPARE 0.000 0.000 #12 Solid 1.59 0.00 20.40 Aux 5495 Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 Total Standby Current (Amps) 0.075 1.459 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 0.122 Total Alarm AH Required Total Combined AH Required 1.92 Wire resistances are based upon an ambient tempera ure of 72 degrees F. Because the minimal difference between solid and stranded wi e no differential was made. Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 2.31 Configure Circuits Print Page Wire resistances are based upon an ambient temperature of 72 degrees F. Because of %Drop 0.57% 2.38% 0.00% 0.00% 0.00% of Because of SECTION 4 SECTION 4 DRAWINGS Note: If reduced size drawings are not present in this section, then full size drawings have been furnished attached or separately. Seatronics, Inc. 1501 15th St. N.W. Ste 101 Auburn, WA 98001 253-939-6060 GL BE FIRE SPRINKLER CORPORATION STANDARD RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT • PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Standard Response Series GL -SR Sprinklers are a low profile yet durable design which utilizes a 5mm frangible glass ampule as the thermosensitive element. While the Standard Response Sprinkler provides an aesthetically pleasing appear- ance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and fin- ishes to meet varying design requirements. Standard Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Series GL -SR sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. Assembly is done in the field. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C), 360°F (182°C) 500°F (260°C) Available Upon Request Without Approvals • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze • Deflector - brass • Screw - brass • Lodgement Wire - stainless steel • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with glycerin solution, 5mm size • Escutcheon Assembly - steel • SPRINKLER TEMPERATURE RATING/CLASSIFICATION STANDARD RESPONSE SERIES GL -SR SERIES GL-SR/CNV UPRIGHT CONVENTIONAL STANDARD RESPONSE SERIES GL -SR SERIES GL-SR/SW PENDENT VERTICAL SIDEWALL STANDARD RESPONSE SERIES GL-SR/SW SERIES GL-SR/SW LPCB/CE HORIZONTAL HORIZONTAL SIDEWALL SIDEWALL and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES ORDINARY 35'F/155'F 57°C/`8`C INTERMEDIATE 175'F/2007F 79`C/t43°C HIGH 286'F 141 C EXTRA HIGH 360`F 182 C ULTRAHIGH iiih, 500'F 260°C BULB COLOR ORANGE/RED YELLOW/GREEN BLUE MAUVE BLACK SEPT 2018 N.F.P.A. MAXIMUM CEILING TEMPERATURE GFS -100b (Formerly A-65) STANDARD RESPONSE AUTOMATIC SPRINKLERS SERIES GL -SR UPRIGHT • PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 4.2 (60 metric) 1/2°NPT (15mm) 2 1/4" (5.7cm) Chrome 5,6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) White Polyester' 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester2J 8.0 (115 metric) 3/4"NPT (20mm) 2 7/16" (6.2cm) Wax CoatedL3d NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. 'HORIZONTAL SIDEWALL IS 2 9/16". 'WAX COATING cULus LISTED FOR 155"F (68 C) AND 200°F (93°C) ONLY, EXCLUDING GL8161, GL8151, *FINISHES AVAILABLE ON SPECIAL ORDER. GL5675. GL8176 LISTINGS/APPROVALS STYLE SIN K FACTOR HAZARD ' TEMPERATURE cULus ' FM LPCB s CE NYC - DOB MEA 101.92-E 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) "286°F (141°C) "360°F 360°F (182°C) GL2861 2.8 LH X X X X X X X --- --- -- X GL4261 4.2 LH X X X X X X X -- --- --- X UPRIGHT GL5661 5.6 ALL X X X X X X X X X X X GL8161* 8.0* (W NPT) ALL X X X X X X X -- --- -- X GL8164 8.0 ALL X X X X X X X X X X X GL2851 2.8 LH X X X X X X X -- --- -- X GL4251 4.2 LH X X X X X X X -- -- -- X PENDENT GL5651 5.6 ALL X X X X X X X X X X X GL8151* 8.0` ('/" NPT) ALL X X X X X X X -- -- -- X GL8156 8.0 ALL X X X X X X X Xs X X X VERTICAL GL5675 5.6 LH X X X X X X X X -- — — SIDEWALLt GL8176 8.0 LH X X X X X X X --- -- — — GL2870§ 2.8 LH X X X X X X X -- --- — X HORIZONTAL GL4270§ 4.2 LH X X X X X X X — -- — X SIDEWALL GL5670§ 5.6 LH/OH X X X X X X X X --- — X GL5671a 5.6 LH/OH X X X X X X — -- X X — GL8171§ 8.0 LH/OH X X X X X X X — -- — — CONVENTIONAL GL5668 5.6 LH/OH X X X X X X -- -- X X' — (OLD STYLE) GL8169 8.0 LH/OH X X X X X X -- -- --- X — 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4' TO 12" BELOW THE CEILING. FM APPROVED 4" TO 6" BELOW THE CEILING. INSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. 500°F (260°C) AVAILABLE UPON REQUEST WITH NO APPROVALS. 1/2"NPT, RETRO -FIT ONLY 'LPCB REF. NO. 147c104 ORDERING INFORMATION SPECIFY • Quantity • SIN• Style • Orifice • Thread Size • Temperature • Finish desired • Quantity - Wrenches/Recessed Wrenches - P/N 325390/325391 (1/2"): P/N 312366/325401 (L.0.) • Quantity Protective Caps - P/N 327109 -CAP (Friction Fit Recessed) kila FIRE SPRINKLER CORPORATION SEPT 2018 'BRASS FINISH ONLY WHEN RECESSED "NO FM APPROVALS FOR RECESSED "NO FM APPROVALS OH: ORDINARY HAZARD LH: LIGHT HAZARD ALL: ALL HAZARDS GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com GFS 100b (Formerly A-65) PRINTED U.S.A. pATRIOT RE PROTECTION 4%4 DeasO DESIGN INFORMATION SHEET NAME (Ate.vot $ T,) - LOCATION ':' w� BJP BUILDING 2707 70TH AVENUE EAST TACOMA, WA 98424 TEL (253) 926-2290 FAX (253) 922.6150 DATE b / L 3/'l'e CONTRACTOR CALCULATED BY 'Al *(t 4- yVl --24 oil - CONSTRUCTION: l . CONSTRUCTION: 1 .COMBUSTIBLE OCCUPANCY R TAIL 0 NON-COMBUSTIBLE SYSTEM NO. CONTRACT NO 1 1 ` 0 -77 DRAWING NO t=?- 1 CEILING HEIGHT l 6 %FT SYSTEM DESIGN -NFPA 13: ❑ NFPA 231 ❑ OTHER (Specify) ❑ LT. HAZ. ❑ NFPA 231C: ORD. HAZ. GP. 0 1 k 2 FIGURE ; CURVE O SPECIFIC RULING MADE BY AREA OF SPRINKLER OPERATION DENSITY AREA PER SPRINKLER HOSE ALLOWANCE GPM: INSIDE 1 0 0 HOSE ALLOWANCE GPM: OUTSIDE RACK SPRINKLER ALLOWANCE 1 S" -c) 0 S-� .2 i2,0S.F 0 EX. HAZ. DATE CALCULATION SUMMARY GPM REQUIRED 4 11 "C" FACTOR USED: OVERHEAD SYSTEM TYPE Ik WET 0 DRY 0 DELUGE 0 PRE -ACTION SPRINKLER OR NOZZLE MAKE R-SLiA-BLE MODEL C SIZE '/L" K -FACTOR S- (a2 TEMPERATURE RATING t to S" PSI REQUIRED Zd7 6(.o UNDERGROUND AT BASE OF RISER WATER SUPPLY WATER FLOW TEST DATES TIME 1/TT)" STATIC PSI 14- c RESIDUAL PSI '71" GPM FLOWING 4- 1-8 6 ELEVATION PUMP DATA RATED CAPACITY AT PSI ELEVATION LOCATION S •1 ) ""-" �- S a �+-m GF/.J py. w Y. SOURCE OF INFORMATION l,J TANK OR RESERVOIR CAPACITY ELEVATION /� WELL PR•: FLOW GPM COMMODITY STORAGE COMMODITY CLASS S • - GHT AREA STORAGE METHO,: : ■ 'ILED PALLETIZED LOCATION AISLE WIDT+ RACK 0 cr ❑ SINGLE ROW 0 ❑ DOUBLE ROW 0 ❑ MULTIPLE ROW LONG FL INAL CONVENT • - LLET lg TINATIC STORAGE SLAVE PALLET - • SOLID SHELVING 0 CING IN INCHES TRANSVERSE CLEARANCE FR ❑ ENCAPSULATED ❑ NON - ENCAPSULATED P OF STORAGE TO CEILING FT ZONTAL BARRIERS PROVIDED SPOKANE, WA OFFICE TEL (509) 926-3428 FAX (509) 926.3708 PATRIFP099CF VANCOUVER, WA OFFICE TEL (360) 699-4403 FAX (360) 699-4485 IN. SUBfITTAL SERIAL NO:2454H-09 CATHERINES AT PARKWAY SUPERCENTER 11-0776 .20/1500 06-22-1998 PAGE 1 FLOW TEST RESULTS STATIC 145.00 PSI RESIDUAL AT 4586.0 GPM 74.00 PSI PRESSURE AVAILABLE AT 510.9 GPM 143.78 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 231 33.81 24.00 5.62 36.18 232 29.86 24.00 5.62 28.23 233 33.29 24.00 5.62 35.08 234 27.87 24.00 5.62 24.59 235 33.14 24.00 5.62 34.78 236 26.54 24.00 5.62 22.30 237 24.82 24.00 5.62 19.50 238 24.05 24.00 5.62 18.31 239 22.84 14.87 5.62 16.52 240 28.77 24.00 5.62 26.20 241 27.13 24.00 5.62 23.30 242 26.03 24.00 5.62 21.44 243 24.66 24.00 5.62 19.26 244 24.00 24.00 5.62 18.24 245 24.08 24.00 5.62 18.36 TOTAL WATER REQUIRED FOR SYSTEM OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 410.88 GPM 100.00 GPM 510.88 GPM 61.01 PSI 4AXIMUM PRESSURE UNBALANCE IN LOOPS 0.096 PSI !RAXIMUM VELOCITY IN PIPES 22.57 FPS SUBMITTAL SERIAL N0:2454H-09 ,CATHERINES AT PARKWAY SUPERCENTER 11-0776 .20/1500 06-22-1998 PAGE 2 FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 213 244 Q 24.00 214 24.5 213 214 Q 24.08 Q 24.08 1.104 L 2.33 0.1422 PT 18.24 (244) F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 1.18 PT 18.41 (213) 1.104 L 2.33 0.1430 PT 18.36 (245) F=E F 3.00 PE -1.01 DR C120 T 5.33 PF 0.76 1.452 L 8.00 0.0377 PT 18.11 (214) F=0 F 0.00 PE 0.00 BN C120 T 8.00 PF 0.30 212 213DQ 24.00 1.452 L 8.00 0.1354 PT 18.41 (213) Q 48.08 F=0 F 0.00 PE 0.00 BN C120 T 8.00 PF 1.08 PT 19.49 (212) 212 243 Q 24.66 1.104 L 2.33 0.1495 PT 19.26 (243) F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 1.25 211 212DQ 48.08 1.452 L 8.00 0.2912 PT 19.50 (212) Q 72.74 F=0 F 0.00 PE 0.00 BN C120 T 8.00 PF 2.33 PT 21.83 (211) 211 242 Q 26.03 1.104 L 2.33 0.1651 PT 21.44 (242) F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 1.38 210 21IDQ 72.74 1.687 L 8.00 0.2470 PT 21.81 (211)'. Q 98.77 F=0 F 0.00 PE 0.00 BN C120 T 8.00 PF 1.98 PT 23.79 (210) 210 241 Q 27.13 1.104 L 2.33 0.1783 PT 23.30 (241) F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 1.49 209 210DQ 98.77 1.687 L 8.00 0.3869 PT 23.78 (210) Q 125.89 F=0 F 0.00 PE 0.00 BN C120 T 8.00 PF 3.10 PT 26.88 (209) 209 240 1.104 L 2.33 0.1988 PT 26.20 (240) Q 28.77 F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 1.66 SUBMITTAL SERIAL NO:2454H-09 CATHERINES AT PARKWAY SUPERCENTER 11-0776 .20/1500 06-22-1998 PAGE 3 FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 10 209DQ 125.89 1.687 L 4.33 0.5662 PT 26.85 (209) Q 154.66 F=2T F 20.00 PE 0.25 NR C120 T 24.33 PF 13.78 PT 40.88 ( 10) 208 238 1.104 L 2.33 0.1427 PT 18.31 (238) Q 24.05 F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 1.19 PT 18.49 (208) 207 237 1.104 L 2.33 0.1512 PT 19.50 (237) Q 24.82 F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 1.26 PT 19.75 (207) 206 236 1.104 L 2.33 0.1712 PT 22.30 (236) Q 26.54 F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 1.43 PT 22.72 (206) 205 235 1.104 L 2.33 0.2583 PT 34.78 (235) Q 33.14 F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 2.15 203 205 Q 33.14 204 234 Q 27.87 1.687 L 10.00 0.0328 PT 35.92 (205) F=0 F 0.00 PE 0.00 BN C120 T 10.00 PF 0.33 PT 36.25 (203) 1.104 203 233 1.104 Q 33.29 L 2.33 0.1875 PT 24.59 (234) F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 1.56 PT 25.14 (204)•. L 2.33 0.2604 PT 35.08 (233) F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 2.17 201 203DQ 33.14 1.687 L 10.00 0.1186 PT 36.24 (203) Q 66.43 F=0 F 0.00 PE 0.00 BN C120 T 10.00 PF 1.19 PT 37.43 (201) 202 232 1.104 L 2.33 0.2130 PT 28.23 (232) Q 29.86 F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 1.77 PT 28.99 (202) 201 231 1.104 L 2.33 0.2679 PT 36.18 (231) Q 33.81 F=T F 6.00 PE -1.01 DR C120 T 8.33 PF 2.23 SUBMITTAL SERIAL NO:2454H-09 CATHERINES AT PARKWAY SUPERCENTER 11-0776 .20/1500 FROM TO FLOW GPM 8 201DQ 66.43 Q 100.23 208 239 Q 22.84 207 208DQ 24.05 Q 46.89 206 207DQ 24.82 Q 71.71 204 206DQ 26.54 Q 98.25 202 204DQ 27.87 Q 126.12 9 202DQ 29.86 Q 155.98 9 10 Q 154.66 8 9DQ 155.98 Q 310.64 2 8DQ 100.23 Q 410.88 0 2 Q 410.88 DIAM IN 1.687 NR 1.104 DR 1.452 BN 1.452 BN 1.687 BN 1.687 BN 1.687 NR L F=2T F C120 T L F=2E F C120 T L F=0 F C120 T L F=0 F C120 T L F=0 5 C120 T L F=0 F C120 T L F=2T F C120 T 2.727 L F=0 F NC C120 T 2.727 L F=0 F NC C120 T 2.727 L F=T F NC C120 T 7.981 F=GV,CV,ALV/T,2E FM C120 EQUIV PIPE LEN/FT 06-22-1998 PAGE 4 P -LOSS PSI/FT PRESSURE SUMMARY PSI 1.33 0.2538 PT 37.40 (201) 20.00 PE 0.25 21.33 PF 5.41 PT 43.06 ( 8) 12.63 0.1297 PT 16.52 (239) 6.00 PE -0.43 18.63 PF 2.42 9.75 0.00 9.75 10.50 0.00 10.50 10.00 0.00 10.00 10.00 0.00 10.00 1.33 20.00 21.33 12.00 0.00 12.00 0.1292 PT 18.51 (208) PE 0.00 PF 1.26 0.2836 PT 19.77 (207) PE 0.00 PF 2.98 0.2446 PT 22.75 (206) PE 0.00 PF 2.45 0.3882 PT 25.20 (204) PE 0.00 PF 3.88 0.5751 PT 29.08 (202) PE. 0.25 PF 12.27 PT 41.60 ( 9) 0.0546 PT 40.92 ( 10) PE 0.00 PF 0.66 8.00 0.1984 PT 41.58 ( 9) 0.00 PE 0.00 8.00 PF 1.59 18.17 0.3328 PT 43.17 ( 8) 19.00 PE 0.00 37.17 PF 12.37 L 60.00 0.0018 PT 55.54 ( 2) F 155.00 PE 5.09 T 215.00 PF 0.39 PRESSURE AVAILABLE AT NODE 0 AT 510.9 GPM MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.096 PSI MAXIMUM VELOCITY IN PIPES 22.57 FPS PT 61.02 ( 0) 143.8 PSI TORRID 17580 SOUTHCENTER PKWY, SPACE #21 TUKWILA, WA 98188 FIRE DETECTION & ALARM FIRE A! ASM GENERAL ELECTRICAL \OTES 1. THE INSTALLATION OF THE SYSTEM(S) SHALL MEET THE REQUIREMENTS OF THE SPECIFICATION, NFPA 70 (NEC), NFPA 72, ALL APPLICABLE LOCAL CODES, AND THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. 2. FASTEN EQUIPMENT TO STRUCTURAL MEMBERS OF BUILDING OR METAL SUPPORTS ATTACHED TO STRUCTURE, OR TO CONCRETE SURFACES. 3. ALL PANELS SHALL BE MOUNTED WITH SUFFICIENT CLEARANCE FOR OBSERVATION, TESTING AND MAINTENANCE. ALL JUNCTION BOXES & COVERS SHALL BE PAINTED RED. 4. ALL WIRE SHALL BE SUPPLIED AND INSTALLED IN COMPLIANCE WITH THE REQUIREMENTS OF NFPA 70, ARTICLE 760 AND AS NOTED ON THE DRAWINGS. 5. A CONSISTENT COLOR CODE FOR FIRE ALARM SYSTEM CONDUCTORS SHALL BE USED THROUGHOUT THE INSTALLATION. 6. WIRE RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION SHALL BE DETERMINED IN THE FIELD BUT SHALL GENERALLY CONFORM TO TO THE LAYOUT SHOWN. INSTALLER SHALL MAINTAIN A SET OF DRAWINGS WHICH SHOW ALL CHANGES IN ROUTING OF CONDUIT AND/OR CABLING. A COMPLETE SET OF THESE "MARKED UP" DRAWINGS SHALL BE PROVIDED TO SEATRONICS UPON COMPLETION OF THE INSTALLATION. 7. ALL NAC DEVICES SHALL BE INSTALLED IN THE SEQUENCE SHOWN ON THE DRAWINGS. 8. ALL FIELD WIRING SHALL BE TESTED FOR SHORTS, OPENS AND GROUNDS PRIOR TO CONNECTION TO THE CONTROL PANEL AND BEFORE DETECTORS ARE PLUGGED INTO THE BASES. 9. SHIELD DRAIN WIRE: UNLESS OTHERWISE NOTED, CABLE SHIELD DRAIN WIRE SHALL BE GROUNDED ONLY AT THE THE PANEL/MODULE OF CIRCUIT ORIGIN. AT ALL OTHER LOCATIONS DRAIN WIRE SHALL BE SPLICED THROUGH AND INSULATED FROM CONTACT WITH ANY POTENTIAL GROUND SOURCE. SYSTEM DRAWI\G INDEX INCLUDED IN SET DRAWING NO. SHEET NO. DRAWING TITLE SEQ. NO. X 111073 FA01 COVER, EQUIPMENT LEGEND, BOM, RISER 1 X 111073 FA02 FIRE ALARM FLOOR PLAN 2 X 111073 FA03 CONNECTIONS DIAGRAM 3 SEQUENCE OF OPERATION - ABBREVIATED: ACTUATION OF ANY MANUAL ALARM STATION, SPOT TYPE SMOKE DETECTOR OR WATER FLOW ALARM SHALL: 1. ILLUMINATE THE "ALARM" INDICATING LAMP ON THE DEVICE IN ALARM. 2. LIGHT THE "RED" ALARM LAMP ON THE FACP (FIRE ALARM CONTROL PANEL). 3. ANNUNCIATE THE APPROPRIATE "FIRE ALARM" MESSAGE ON THE FACP LCD DISPLAY. 4. SOUND THE FACP INTERNAL AUDIBLE DEVICE. 5. ACTIVATE ALL AUDIBLE AND VISUAL ALARM NOTIFICATION DEVICES. 6. INITIATE THE APPROPRIATE FAN/DAMPER SHUTDOWNS FOR THE AFFECTED FLOOR. 7. TRANSMIT A "FIRE ALARM" SIGNAL TO THE MONITORING STATION. ACTUATION OF A DUCT DETECTOR OR SPRINKLER VALVE SWITCH SHALL: 1. ANNUNCIATE THE APPROPRIATE "SUPERVISORY" MESSAGE ON THE FACP LCD DISPLAY. 2. LIGHT THE "SUPERVISORY" LAMP ON THE FACP. 3. TRANSMIT A "SUPERVISORY" SIGNAL TO THE MONITORING STATION. TROUBLE CONDITIONS CAUSED BY DETECTION SYSTEM FAULT, ANY AIR SAMPLING DETECTION SYSTEM FAULT, NOTIFICATION APPLIANCE POWER SUPPLY FAILURE OR TRANSFER TO BATTERY POWER SHALL: 1. ANNUNCIATE THE APPR-O-PRIATE "TROUBLE" MESSAGE ON THE FACP LCD DISPLAY. 2. LIGHT THE "TROUBLE" LAMP ON THE FACP AND BOTH REMOTE ANNUNCIATOR. 3. TRANSMIT A "TROUBLE" SIGNAL TO THE MONITORING STATION. ACCEPTED D Without Comments 75 As Noted in Red p Per The Attached Letter "hese plans have been reviewed by The Tukwila Fire evention Bureau f o-rormance with current City :dards. Acceptti =:.= ;.object to errors and ,zissions which cin =a ; _"orae violations of adopted -: ?dards and r)76- ncz- ,he responsibility for the -..eguacy of des=gr: _ .i ::,-c.;.f- with the designer. ditions, deiebous . x tr; ;hese drawings after cnis date wil': vo d t t r ;'d w'a require a r esubmittai of -" bcf ent approval. Final accepta-R = k- i= „_t and inspection by The Tukwila Fire Date: cl -lel -I ,; , 3 I1 Zi s Vc, I l S ►+„ot4c.. d4+. 41, e.g. ?Ow.- Supp')/ - Fire Permit Number To schedule inspections call 206-575-4407 SYMBOL ADD. PROJ. QTY ORIG. BASE PROJ. QTY EQUIPMENT LEGEND / BILL OF MATERIAL ITEM DESCRIPTION PART NUMBER MANUFACTURER FACP 0 1 1 FIRE ALARM CONTROL PANEL FC922 FSE 0 1 2 FIRE SIGNAL EXPANDER 5495 SIEMENS SILENT KNIGHT 0 0 1 3 ADDRESSABLE PULL STATION HMS—D 0 3 4 CEILING MOUNTED HORN STROBE HSRC SIEMENS WHEELOCK t�t 0 6 5 CEILING MOUNTED STROBE STRC WHEELOCK 0 3 6 WALL MOUNTED HORN STROBE HSR WHEELOCK 0 0 7 WALL MOUNTED STROBE STR WHEELOCK 0 E 8 ADDRESSABLE SMOKE DETECTOR OP921 SIEMENS 0 E 9 ADDRESSABLE MINI MONITOR MODULE HTRI—D SIEMENS I-®4 WP 0 E 10 WEAHTER PROOF WALL MOUNTED HORN STROBE ASWP DD 0 E 11 CONVENTIONAL DUCT DETECTOR EXISTING WHEELOCK SYSTEM SENSOR RTS 0 E 12 DUCT DETECTOR TEST SWITCH EXISTING SYSTEM SENSOR SCOPE OF WORK: THE SCOPE OF WORK FOR THE TORRID AT SOUTHCENTER PARKWAY IS INSTALL NOTIFICATION DEVICES FOR PROPER COVERAGE FOR THE PURPOSE OF TENANT IMPROVEMENT. PAID SEP 13 2319 93cc 3 0, SUBMITTAL SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE SUBMITTAL SEATRONICS FIRE PROTECTION SERVICES ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN NG DATE 9/4/19 CHECKED SUBTITLE FIRE ALARM COVER, NOTES, BOM REV. JOB NO. REV. SYM. REV. DATE APPROVED BY DEPT. DATE ENGINEER NG 9/4/19 CHECKED APPROVED APPROVED TITLE TORRID SOUTHCENTER PKWY FIRE ALARM TENANT IMPROVEMENT TUKWILA, WA SHEET FA01 SEQ. 1 JOB NO. 111073 DWG NO. 111073—FA01-0 EXISTING DEVICE TO BE CHANGED WITH ANEW H/S cf)l- 8 STOCK ROOM EOL 110cd 1/1/3 1\\\NNN\NN\\\NN\\\\XXN\NXNNX\\NNNN EXTERIOR 0 EXISTING DEVICES TO REMAIN. ELEC. RM. CORRIDOR 1/2/1 15cd R.R. 95cd 1/2/8 ga 1/2/9 fg<I EOL EXISTING TO REMAI DEVICES N. • FY POINT NUMBER FITTING FITTING EXISTING SALES FL CEILING H ED 15cd FITTING FULLY SP EIGHT @12'A F TYPICAL INKLEKED I) PICAL I HROUGHOU I FIRE AL/L\ DLA\ SCALE: 1 /4"= 1 1* FACP FSE EEI DD RTS WISE CO LEGE\D FIRE ALARM CONTROL PANEL FIRE ALARM SIGNAL EXPANDER WALL MOUNTED HORN/STROBE WALL MOUNTED STROBE CEILING MOUNTED HORN/STROBE CEILING MOUNTED STROBE MANUAL STATION SMOKE DETECTOR MONITOR MODULE DUCT DETECTOR DUCT DET. TEST SWITCH E A = SLC DATA COM CIRCUIT — 2#16 TSP, TYPE FPLP CABLE, WEST PENN WIRE # 60990 OR EQUAL OR 2#16 THHN IF IN CONDUIT. B = NOTIFICATION CIRCUIT — 2#14 TSP, TYPE FPLP CABLE, OR 2#14 THHN IF IN CONDUIT. C = ANNUNCIATOR CIRCUIT — 4#16 TSP, TYPE FPLP CABLE, OR 2#14 THHN IF IN CONDUIT. D = TEST SWITCH CIRCUIT — 3#16 TSP, TYPE FPLP CABLE, OR 3#16 THHN IF IN CONDUIT. SUBMITTAL REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE SUBMITTAL SEATRONICS FIRE PROTECTION SERVICES ACCEPTABILITY THS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN NG CHECKED DATE 9/4/19 SUBTITLE FIRE ALARM FLOOR PLAN REV. JOB NO. REV. SYM. REV. DATE APPROVED BY DEPT. DATE ENGINEER NG CHECKED 9/4/19 APPROVED APPROVED TITLE TORRID SOUTHCENTER PKWY FIRE ALARM TENANT IMPROVEMENT TUKWILA, WA SHEET FA02 SEQ. JOB NO. 111073 DWG NO. 111073—FA01-0 0 0 O O 0 p000000aoa 0000000aooaoq p0000a00000000000000noor O O AP O r B / / / A 1 Ycloonoo o 0 RS485 o xi c O O 0 bo 0000aa000000aa000a no 0 0 0 OPERATOR INTERFACE O 0 0 0 SYM / 0 0 0 0 0 1 1 0 O 0 0 O 0 0 0 CI Li I I ❑ L 00 0Q 1 1 1I ❑ 101 00 FC922 BOARD O O O + AUX 24V REVISION BY APPROVED 0 0 0 0 0 ,aa oo( ,0000000( aaaa ALM C NC C NC °SUP T MmIttlai • i i o D G NZ !■hi ❑II NAC C[C13o + 0 0 J 0 0 O O r J� BATTERY BATTERY 0 c0000 0 PWR SUPPLY ( 1) ( ) ( 1 ( 1 ) ( ) ( 1 ( I ) ( ) ( 1 ( l) ( 1 D ( { REMOTE ANNUNCIATOR II 0 OUT + IN D 0 OO=E 1 11 t'1 STYLE 4 SLC CIRCUIT T—TAPPING PERMITTED SMOKE DETECTOR SLC >E - 1b SMOKE DETECTOR TYPICAL—ALL NOTE: T—TAPPING NOT PERMITTED. CONDUCTORS MUST GO IN AND OUT OF EACH DEVICE. 26 1/1/1 NAC CIRCUIT SEE PLAN VIEWS FOR WIRE SIZE EOLR 120VAC 0 DATE SYM REVISION BY APPROVED DATE SUBMITTAL 3#12 SYSTEM WRI\G DETAILS 1/2/1 NAC CIRCUIT SEE PLAN VIEWS FOR WIRE SIZE EOLR SCALE: NONE SEATRONICS FIRE PROTECTION SERVICES ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN NG CHECKED + COM MSI -10B MSI -20B MANUAL STATION TYPICAL—ALL r 1 SIEMENS DUCT SMOKE DETECTOR MODEL FDBZ492—HR TB1 1 2 3 4 REMOTE + REMOTE CNTL REMOTE 11 RD 12 WHT 13 TO REMOTE TEST SW. BLK (WHERE APPLICABLE) SLC ALM. RLY. CKT L RELAY CONTACTS T RATED 120 VAC, 5 6 7 8 10 24VDC, 2.5 AMPS TO SLC CKT. A D WHT BLK RD D CONNECT TO SHUTDOWN CONTROL CIRCUIT FOR AHU VFD OR TO CMOS SYSTEM MONITORING. SEE PLAN FOR CONNECTION INSTRUCTION AT EACH UNIT. TO NEXT SLC CKT. DEVICE -Fa TB2 -[c1] TB3 ® TB1 REMOTE LAMP (WHERE APPLICABLE) MODEL RL—HC, RL—HW AIR DUCT SMOKE DETECTOR WIRING — TYPICAL D� 2 3 4 5 + COM INPUT CH #1 INPUT CH #2 HTRI—D 8 I� EOLR 3.6K MONITORED SWITCHES EOLR I\b Z 3.6K I J DUAL INPUT IFD / A (TYP.) i +C0M 3 INPUT 4 #1 5 CH _ NOT USED HTRI—S 6 EOLR 3.6K _r MONITORED SWITCH SINGLE INPUT IFD 1 2 3 INPUT 4 CH #1 5 r_ RELAY HTRI—R 1 6 + COM 8 EOLR 3.6K MONITORED SWITCH SINGLE INPUT IFD WITH RELAY TYPICAL DEVICE WIRING CONNECTIONS FOR ALL SLC CIRCUIT CONNECTIONS INTERFACE MODULE HTRI-S 470 EOLR DATE 9/4/19 IIIIIIIIIIIIIIIIIIEI-I�Illllllliillll'-1111111111111111111 ��_ O� SPRINKLER WATER FLOW SWITCH NORMALLY OPEN CONTACTS CLASS B WIRING SUBTITLE FIRE ALARM DETAILS SLC 1 COM 3 INPUT 4 CH #1 SHLD.0— 5 INTERFACE MODULE HTRI-S 7 6 16/2 r 470 EOLR C? M VO NC COMM NO NC SPRINKLER VALVE TAMPER SWITCH NORMALLY OPEN CONTACTS CLASS B WIRING REV. JOB NO. SUBMITTAL REV. SYM. REV. DATE APPROVED BY DEPT. DATE ENGINEER NG 9/4/19 CHECKED APPROVED APPROVED TITLE TORRID SOUTHCENTER PKWY FIRE ALARM TENANT IMPROVEMENT TUKWILA, WA SHEET FA03 SEQ. 3 JOB NO. 111073 DWG NO. 111073-FA01-0 CL 1 P1 CL1 P1 CL4 P1 Alip GYP BD SOFFIT ® 7'-O" AFF Nxxxxxxxxx \\\\\\xxxxx‘\\\\ OPEN TO DECK 13'- 6" AFF 1717 13 OPEN TO DECK 01 CL3 ® 13 - 6" AFF AxyA.�w .wswwmw.wwn ..�.ewv��swNv WATER HEATER ABOVE. SEE PLUMBING SHEETS FOR DETAIL GYP BD SOFFIT O 11 -4 AFF GYP BD SOFFIT O 10-6 AFF GYP BD CEILING TO MATCH EXG O 8'-0" AFF -EXG GYP BD CEILING ® 8 '-0 AFF, VIF CL1 P1 CL2 ACT1 GYP BD CEILING 0 10'-6" AFF WITH TENANT FOR ADD! TIO INFORMATION TYP TYP 2X4 SECOND LOOK ACT CEILING O 10'-0" AFF TYP ALL FITTING ROOMS EQ i EQ GYP BD SOFFIT ® 9'-6" AFF CL2 ACT1 2X4 SECOND LOOK ACT CEILING 0 10'-6" AFF Design per NFPA 13 — Ordinary Hazard Group 2 All materials to be new, U.L. listed and F.M. approved All heads to be at least 6' apart with no obstructions ADJACENT TENAI(t • 41 — Relocate Globe Model GL5651 Standard Response 155° Pendents 1/2x 1/2 • 5 — Add Globe Model GL5651 Standard Response 155° Pendents '/2 x '/z FlexHead Sprinkler Drop . . • �El 41:;;�����;��,! .Corrugated stainless steel hose with stainless steel bral .:.;.,.., available in 2', 3',4',5' & 6' legnths . • Multi -Port Bracket • Adjustable Hub • FLEXHEAD • INDUSlRIES'/r..J Flexhead-omme.rcial Ceiling Unit T -Bar Ceiling Installation Model #2024,2036,2048,2060,2072 YP CL1 P1 CL1 P1 to Fire Permit Number q_ s- n3 To In impactions salt 206-575-4407 TEELOX MECHANICAL BRANCH CONNECTOR SIZE A B c 1-1/4x1/2 2 1-1/2 1-3/16 1-1/4x3/4 2-1/16 1-1/2 1-3/16 1-1/4 x 1 2-1/8 1-1/2x1/2 2 1-1/2 1-1/2 1-3/16 1-3/16 1-112 x 3/4 2-1/16 1-1/2 1-1/2x1 2-118 1-1/2 1-3/16 1-3/16 2 x 1/2 2-5/16 1-13/16 1-3/16 2 x 3/4 2-3/8 1-13/16 1-3/16 2 x 1• 2-7(16 1-13/16 1-3/16 2-1/2 x 1/2 2-9/16 2-1/16 1-3/16 SIDEWINDE ( SVG 20) 2-1/2x3/4 2-11/16 2-1/8 2-1011 2-3/4 2-/8 1-3/16 1-3/16 NOT LESS THAN 2-1/2' FOR BRANCHLINES NOT LESS THAN 3' FOR MAINS ACCEPTE ❑ Without Comments ❑ As Nuteo in Red Pe;' The Attach& _Li er "v -se. plans have r e -.rt , eviewe I~v Y Fre i I il)i f Btfrea`_ P- -.»For rn f- soolazt islf:s!o i 1�JI? Ci; l;Ct}"fir _ ToE t lid •".�- restah�ri�.rtr- - Final accep : tThe Tukwila L Date: 9 - Li --I -9 13v: WL¢H/NGTON STj y CERTIF�M..vA�TE OF COM FIRE PROTECTION SPRINKLER SYSTEMS John Thomas DeMartino 9794 -1091 -CG . Level Crown Fire Protection, Inc: CROWNFP044LL as lswiesture • 1 CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 Torrid Parkway Super Center 17580 Southcenter Pkwy Space #21 Tukwila, WA 98188 DATE: i,2,,ko, DRAWN: 4 SCALE: 11.1 PAD /JO 27 20/9 NREE W275 c 7 16: 15: 48 1998 C:\Acad Files\766 Parkway\Catherines FP,dwg 3'-3F' la' '. PRE FAB PARTITIONS/D''CRS FURN,I S-4ED BY PS PLUS SIZES INSTALLED et" CONTRA :TCR TYP. EACI-1 FITTING ROOM. SEE NOTE «2 CN TN;S SHEET - SEE PATRIOT JOB 11-0175 FOR CONTINUATION EXISTING MAIN 11'-9" t -AFF HYDRAULICALLY MOST REMOTE 15001 CALCULATED TO DELIVER .2 GP/. CEMAND AT BASE OF R'SER_ 411 C P M@ 61.10 P S I TYP, /0 2-0 �I 11'-C" AFF. 3-8Y2 Po „- c" AFF. LL - !P 1 0 F 0-11 6-0 T (D PQ N LO � I L o-, w F - w. --O r -';FR :R/'S) Pr). O Q 2t AFF - .21/2 O> - Pe) ' - 6-11 Q RD f csf O -157 / ®P c 1 Co '-61/2" -COL 21/2 21/2 . `' 21/2 2-4 2-9 ©\ 8-0 10'-51/2" \`1/ _ 031 Q / MMINIMMOMM CO O 0 / FO cwt ((._;P1) (231) .\ 1- - CD OF •I 0 -a I_L LL 21/2 -- P C201)Q <231; 8'-0" 1 9'-9„ (Q -COL C) 1-3 O N O•) U t- I r7 F0 3 -WAY P � r C:) CO z" w. -U, } 231) / • F' F \230 / 20 %QF (23) FQ u VE OGLES .=•^-. 8p; / QP is = l / �^ \\ p [�r'AFT-.-1 Lv i� jL �, \231> • OP ;6- O P c F © F. F 0: (231%1 3-41/2- 1 3-T - / QP 0 10 it r GECK . U/4 51 -,ELVES AND STANDARDS. FURvIS.-ED BY P5 PLUS SIZES AND INSTALLED BY CONTR4CTCR 8x21/2 MECHANICAL ;TEE SPRINKLER PLAN SCALE: 1/4" = 1'-0" FLOW TEST STATIC RESIDUAL FLOW LOCATION DATE SOURCE 145 PSI 74 PSI 4586 GPM S.170TH & SOUTHCENTER PKWY. 7/12/95 W.S.&R.B. GENERAL NOTES 1. DROPS ARE 1(1-7) W/ ADN, U.N.O. 2. TYPICAL HANGER IS EYELET, LAG, ROD, & RING. 3. ELEVATION OF NEW PIPING IS 12'-4" A.F.F. 4. MAXIMUM LENGTH OF UNSUPPORTED ARMOVER IS 12". MAXIMUM DISTANCE FROM HANGER TO END SPRINKLER ON BRANCHLINE IS 12". 5. GROOVED COUPLINGS ARE RIDGID TYPE. HANGER LEGEND A U" HOOK 8 COACH SCREW ROD D BM. CLAMP W/ STRAP E EYELET F FLUSH SHELL G CEILING FLANGE H SIDE BEAM BRACKET K SHORT CUP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T U Y FITTING LEGEND PIPE -O -LET PLAIN END FIT PETTING SN GROOVED SHAPED NIPPLE TSN THREADED SHAPED NIPPLE 2 - WAY EARTHQUAKE BRACE 4 - WAY EARTHQUAKE SPACE STRUCTURE TO CENTER LINE OF PIPE IN INCHES SPRINKLER LEGEND T � 1 Q n = SPRINKLER ORIFICE SIZES AND TYPE i a. 0 a. t 3 W W 4 2- 16 1$ SPRAY 17 SPRAY 3 7 _ $ T6 -2 SIJEi*ALL EP TYPE STATE CERTIFICATION TEMP PATIN4 165' 212` sm' t� rc4 i. 4 4.)� 1" • CITY OF TUKWILA t:,(41 mANIJI SPRINKLEP. HEADS USED TYPE 'These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city 'standards. Acceptance is subject to errors and emissions which do not authorize violations of adopted s standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after ibis date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau.. XEI ACCEPTED 1Nithout Comments As Noted In Red Per Pie Attached Letter TUKWILA FIRE DEPARTMEN1 Please call: 575-4407 and give this job end exact address for shut- down or restoration approval. KEY PLAN VICINITY MAP QUALaY CONTROL BY - DATE APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. ALI. MATERIAL AND EQUIPmENT TO BE NEW AND UL LISTED OR FM APPROvED. 2. PiPING CA•ENS,ONS APE CENTER TO CENTER EXCEPT THSERS AND DINiENS10.45 SHOwN THUSLY (1-6) wHICH ARE END TO END_ 3. EARTHQUAKE BRACING SHALL. BE PROvIDED IN ACCORDANCE wITH 4. PIPE HANGERS AND METHOD Of HANGING TO BE IN ACCORDANCE WITH S. PIPING SHALL BE IN ACCORDANCE veTH NFRA PAmPHLET NO. 13, APPUCABLE EnIT EN 6. JOINING OF PIPE AND FITTINGS. THPEADED & WELDED. SHALL BE IN ACCOREANCE WITH NFPA PAIAPHLET NO. 13, APPLICABLE EDITION. 7. CWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. a. ALL wiPING OF ELECTRICAL DEVICES OF REQUIRED) TO BE PROV12,ED ay OTHERS 9. PAINTING OF PIPE 8: EQUIRMENT OF REQUIRED) TO BE PROVIDED BY OTHERS 10. FURRING OF PIPE & EQUIPmENT OF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA 1. HYDRAULIC DESIGN CRITERIA IS FOR ORDINARY HAZARD PIPE SCHEDULE. PIPE NOTES 1. NEW PIPING IS AWED "XL'. REVISIONS NO DATE DESCRIPTION CONTRACT WITH: SIERRA CONSTRUCTION 16715 NE 79th ST. REDMOND, WA 98052 TODD RANKIN 206-574-0063 FILE PROJECT NAME: CATHERINES SOUTHCENTER PARKWA 10 FIRE PROTECTION 2707 70TH AVENUE E. TACOMA, WA 98424 TEL FAX 253) 926-2290 253) 922-6150 DESIGNER MARK METZGER SHEET DATE 6/23/98 JOB NO. 11-0776 OF 1 17-1