HomeMy WebLinkAboutPP - 15016 MACADAM RD S BLDG III - FOSTER CREEK APARTMENTS III - PERMITS AND PLANS15016 MACADAM RD S BLDG III
ASSOCIATED PERMITS
99-F-341
City of Tukwila
Fire Department
FIRE WATCH REQUIRED
Due to the inoperative fire protection system(s) in your facility, you are required to provide a fire watch
per City of Tukwila Ordinance #2437, section 16.40.120-D and Ordinance #2436, section 16.42.100-C
(see reverse side). The fire watch shall be maintained until the system(s) are operational as determined
by the Tukwila Fire Marshal's Office. FAX paperwork to 206-575-4439 to verify the completion of
repair work and/or the restoration of system monitoring, in order to end the fire watch.
The fire watch is required 24 hours a day. Designated employees may serve as the fire watch during
business hours, while performing their regular job. Fire watch personnel must be aware of, and accept
the duties of the fire watch.
After hours fire watch personnel must be on location and must patrol the building following the close of
business. Every two hours they must call 206-971-8737 and leave a message stating the following:
1. Your name.
2. Street address of firewatch location.
3. Time of day.
4. If everything is OK, state all clear. If you discover an emergency during your patrol , call
9-1-1 immediately to report it.
Date: 2 /;•// 7 Inspectors: E5—/ Start time: /o-2- (,
Reason For Fire watch: ?c4 S".414', avt. AA\ch vit/ Incident #:
Business Name:
Business Address:
Business Phone:
POCK- 1-17r(—
Person in Charge:,.. (101•124 Signatur
W — Fire Marshal's Office Y — Owner/Manager
Rev. 7/29/14 T.F.D. Form F.P. 41
Tukwila Fire Marshal's Office • Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshal@tukwilawa.gov
From: KEVIN GE To: Nick Olivas
1
v
a
Date: 11/22/99 Time: 2:53:30 PM
Page 1 of 1
Longwell Construction Inc.
Attention: Nick Olivas Fire Chief
From: Kevin Ge Longwell Company
Date: 11,2299 1:48 PM
RE: Tukwila Garden Apartments Fire Alarm System
FILE
Chief Olivas:
I felt so terrible sorry to bother you again regarding the fire alarm system at Tukwila Garden. Since you have
approved our fire alarm plan (Permit No. 994 3411 a month ago. I have been trying to purchase the equipments
and designate an installer. I have selected the electrician and received Electrical Work Permit from Labor
Industry office. But the regional distributors of Notifier (our equipment manufacturer) refused to sell
equipments only. They want to sell their full services which we don't need. So I have to switch to Silent Knight
as our supplier. The package is very similar to the previous one, except the name. I revised our new equipment
list as below. Please also find enclosed current rating and battery cal.
Equipment Finish Schedule
QTY
Marruf.
Model
DESCRIPTION
LOCATION
1
Silent Knight
SK -6324
Analog Fire Alarm Control Panel
with basic equipment kit
office
4
Silent Knight
DSCBD712
Battery, 12V, SAmps,7 hours
offce
34
Silent Knight
SIKPSDATK
Pull station/ tamper cover and alarm
2 @ each staircase
4@ office
4
Silent Knight
SIKSD505APS
Smoke detector
office
4a
SIKSD5056AB
Base for above
1
Silent Knight
SIKSD505AHS
Heat detector
office
la
SIKSD5056AB
Base for above
6
Wheelock
HS -241575W
24vdc, 75 Candela horn/strobe
1@each bid 3@office
93
Wheelock
MH -12/24R
mini horn
1@each unit
1
Silent Knight
S15895XL
Aux Power
office
Please give me your comments on this revision. You can contact me at (425) 747 7890 at any time during the
business hours. Thank you again for your support.
Sincerely yours
Kevin Ge
Project Mgr
/5-'?)
General Contractor Since 19(19 (ONGWCIO33PA Pu don{ 59116etle+rue W 98003
Tel (4251'11190 Fax: (4251 ?111194
From: KEVIN GE To: nick Olivas
SILENT
KNIGHT
Instructions: fill in shaded data fields
Date: 11/22199 Time: 2:56:12 PM Page 1 of 1
5207 Battery Calculation Worksheet
(aR currents stated in mA)
11/22/99
Device
Quantity of
Standby mA
Alarm mA
Tot. Device
Tot. Device
Description
Devices
Per Device
Per Device
Standby mA
Alarm mA
5207 Control Communicator
3980.9
120
200
120
200
5207 Programmed Notification Circuits (4 Max)
0
45
0
0
5207 programmed Alarm Relays (4 Max)
0
35
0
0
5210 Zone Expander
40
40
0
0
5220 Direct Connect Module
50
50
0
0
5230 Remote Annunciator (7 Max)
60
120
60
120
4180 Status Display Module (2 Max)
20
140
0
0
5260 Printer Interface
25
25
0
0
180
320
Auxilliary Devices (list all)
Notification Appliances (list all)
Notification Appliance Totals
N/A
N/A
N/A
N/A
N/A
N/A
105
N/A
N/A
N/A
N/A
N/A
N/A
N/A
870
0
2790
0.9
0
0
3660.9
Summary Section
Standby Hrs. Required
Alarm Sounding Minutes
Total System Standby mA
180
Total System Alarm mA
3980.9
Total System Standby A/H
4.32
Total System Alarm AIH
A/H Battery Required
Recommended NH Battery
0 33
4.65
5.58
a
0
6661;- 130 111
EJLEEDER
111111111111
111111111111
V.
1111111111'
111111111111
"11111111111
011111111111
p.
.11111111111
1111111111111
1111111111111
''111111111
''11111116
a
111111111111
111111111111
11/11111111
11111111111
11111111111
11111111111
11111111111
11111111111
_
•
EXTERIOR
HORN/STROBE
m
13'9
STORAGE ( n
e!✓
Jl J
HEAT DETECTOR
PUBLIC LAUNDRY ROOM —
>PULL STATION
(moi
SMOKE DETECTOR
OFFICE
Fire Alarm Control Panel
PULL STATION
ECTOR
4' h 11'3
PULL STATION
Iso,
SMOKE DETECTOR
MANAGER'S LAUNDRY ROOM
� I
STORAGE ROOM
to
..yw'eE+n+en
1+d
(sol
SMOKE DETECTOR
OFFICE
PULL STATION
Office Fire Alarm Plan
North
N
Fire Alarm Plan
Sheet 2 of 4
Sc ale = /g
B ELECT BASEBOARD
UNIT A
504 WI
DINING ROOM
BATH
Iso
SMOKE DETECTOR
S ELECT
BASEBOARD
L
CONC PAD
UP
v
CL
CL
f
ELECT BASEBOARD
LIVING ROOM
UNIT 8
705 INS
5 ELLCT BASEBOARD r
DINING ROOM KITCHEN
BEDROOM #1
ire t�
ISE'
SMOKE DETECTOR
)1
58
7
Sl
VENT
1
BATH
SD SMOKE DETECTOR
SMOKE DETECTOR
5 ELECT BASEBOARD
BEDROOMI2
5 ELECT BASEBOARD
78
211 ,
174
10'5
TUKWILA GARDEN
GROUND FLOOR PLAN
NORTH
173 4 2'8
Building Plan
Sheet3of4
DECK
3' PORCH OVERHANG
911
DECK
S ELECT BASEBOARD
LIVING ROOM
S ELECT BASEBOARD
U594 AO
BATH
DINING ROOM
{-
SMOKE DETECTOR
VENT
SMOKE DETECTOR
BEDROOM
5
S ELECT
BASEBOARD
DN
CL CL
n
SELECT BASEBOARD
UNIT C
705 wet
DINING ROOM
LIVING ROOM
S ELECT BASEBOARD
NTJ
KITCHEN
BEDROOM t1
sol
SMOKE DETECTOR
I
SMOKE DE
S ELECT BASEBOARD
VENT
SMOKE DETECTOR
BEDROOM #2
S ELECT BASEBOARD
10'5
12'3
28
TUKWILA GARDEN
SECOND FLOOR PLAN
NORTH
Building Plan
Sheet 4 of 4
70011s
ti % ytp vc i�
q4- Y% 1 l/Ow (.
Scale /8,
0,5 rf,rntTr
!‘",... 1 Fe;.f 4A
�•�,i.'.', ;:, a'i t.y:C; I,.':t!er
{ a r s'1y?, Y:r;,P'r Key p,>,..,,yyj rt -!e. 'Tukwila
.re>)t :.
i ri .;�;.:,.. ::'; ' ��^f ::r o(.: and
Vfi'?ici): dpi '' ' '.Jt ;'I.:r; 1i` JSi :ic , of adopte'.J
..r.-iY .y ir;+ii`r:�si. '�':. � tk' �G.s •"'i.: C !sty for tie
1. ;{... i' u acv 0, a Lsign re:,Is
o :7.-:letIons or revision !t ; ravings after
m; , nate will void this acceptance end v'fri,,, require a
resubmittal of revised drawings for subsequent approval.
Final acceptance is subject to field test and inspection by
The Tukwila Fire Prevention Bureau.
Date: /0 l? �1 By: ,511
TUKWILA FIRE DEPARTMENT,
Please call: 575.4407
and give this job
No. /a1 -r-3 `I I
and exact address for shut•
down or restoration approvals
▪ tre
• sAmmo
-
/f'1;�;�ti..,�, 70 a(s Q „tit ,1 Yr q kct.J r. L tow
L Ct k -' (co, S ti l I � { Z-oh.,e 61 S eru r41 I/
(,,, ) e c+ (-A. 1 y c yrv.. j' f K)b.. L
✓.L"$ J t &? 01Oo.- OCL C -I -to- yC�vlrec� 1-t ecw� voo'''
U,1.- S 1-i�� ►.•.a,, �U�:� rYeL�,�.vev
Legend:
(SD)
(FAcI
Pull Station
Heat Detector
Horn/Strobe
Smoke Detector
Control Panel
FACP
r 1 r ti r r-1 r , r
OC'CC CD CO CCS CD CC' CC (CCS OD
J L+ L+ - L+ -J L+ -J L+ -JJ L+ -J L+ J + L+ -J
HD SD HD SD HD SD PS PS PS PS HS
ZONE#1 OFFICE
WiringDia ram
SHEET o
Legend:
HD Heat Detect
PSPj12 Station
MH Mini Horn
HS HORN/STROBE
SD Somke Detec
FAC P
ZONE#2 Building#1
`C C)
/ L+ 2) L+ -.
PS MH PS
r
C
NH PS
CD CD (+
MH PS MH
, r
r
r
v
MH PS
L+ -J
MH
♦ + J + J +
(k;''
J + + jj + J (t7;
PS MH PS MH PS MH PS MH PS MH, PS
T
GlyD)(CC)(C_D)(CO(C�t;C`CO
MH PS MH PS MH PS MH PS MH MH
r s r 1 r
C) (C C C D C
- L+ + -J L+ -J L+ -J
MH MH MH MH MH
CC) (C3 ICO�(CD)(CCCC�)`CC `CC
+ J + J + + + - - L+ -J L+ -
MH MH MH
D
+ L+ J L+
MH MH NH
(?J
MH
(2J
r r _
D) C+ �) L+ �� (+ +
MH MH MH MH MH MH
MH
MH
MH
MH MH MH MH MH MH
CD CD
+ -J L+ -J
r
C C :1
+ -/ L+ -
MH MH
(?)
a C 4D) (C 0) (C DI `C C 'C D
+ t+ + + L+ -J L+ -J
MH
MH MH MH MH MH MH MH MH MH MH
D
`+ -) N.+ -) +
MH MH 'MH MH
-J
F=
r
MH MH MH MH MH MH
+ C) E?HS2
Wiring Diagram
SHEET 2 of 2
Legend:
HD Heat Detect
PS�p�11] Station
MH
Mini Horn
HS
HORN/STROBE
SD
Smoke Detec
FACP
PS
MH
ZONE#3 Building#2
PS
r
`. .� t,
`+ - `+
MH
t+
OP) rC D (C
+ -
MH PS
PS MH PS
• r t r 1
+
(CD • �+ D �+ D
MH PS MH
+-)C+-)C+-t+
C PS MH PS MH PS MH PS MH PS MH PS MH
MH
i
„++
� DJC+�
MH MH MH
3 D ( ) ) _ + -•?) (t -?) WS) -
MH PS MH PS MH PS MH PS MH MH MH MH! MHMH MH MH MH MH MH-
+2Gf_C+2)(+2
r
t+
2)
MH MH MH MH MH MH MH MH MH MH MH
(u �+ - I + i t� -
MH MH MH MH MH MH MH
r
r ti
C i C)CJ
MH MH HS
t+
MH
� rC�CC���:��:�]C�� �.c
`+ + + + + + q,+ -
MH MH MH NH NH NH MH MH
7
•
•
•
•
•
•
•
•
•
12826 SE 401h Lane Suite 4203
Bellevue WA 98006
LongwellCompany. Avner of Tukwila Garden Apartments
October 4, 1999
City of Tukwila Fire Department
444 Andover Park East,
Tukwila, WA 98188
Attention: Nick Olivas/ Fire Marshal
RE: Fire Alarm System for Tukwila Garden Apartments —15016 Macadam Road South
Dear Mr. Olivas:
Thank you so much for giving us this opportunity to provide our tenants a safer living environment. I
am submitting this plan with great gratitude. We could have not done it without your support. Please
find enclosed documents as following:
Tukwila Garden site plan
Tukwila Garden Fire Alarm Plan
Devices specifications
Equipment Finish Schedule, Current Rating and Battery Cal
Wiring Diagram
Thank you again for your time and consideration, and best regards from Tukwila Garden
managements and tenants.
Sincerely,
Stanley Xu
President and Executive Director
•
We Care!
Q ��fa0
. .Irr..N w.., M..' w. •.'www o
Lon
October 1, 1999
12826 SE 40ih Lane Suite 4203
Bellevue WA 98006
�any wtict Guido* Apatiman
EAuiaments Finish Schedule
QTY 'Manuf.
DEVICE
Model
DESCRIPTION
LOCATION
1
Notifier
BEAFP-200G
Analog Fire Alarm Control Panel
with basic equipment kit
office
2
Notifier
PS -1270
Battery, 12V, 5Amps,7 hours
offce
34
Notifier
BNG-1R
Pull station/ tamper cover and alarm
2 @ each staircase
4@ office
3
Notifier
SDX-551
Smoke detector
office
3
Notifier
FDX -551
Heat detector
office
3
Notifier
NS-2475WFR
24vdc, 75 Candela horn/strobe
1@each bld
facing Macadam Rd
62
Notifier
NH -24-R
mini horn
1@each unit
Current Ratin
QUANTITY
DEVICE
CURRENT
MWmPLiY
1
Notofier BEAFP-200G Control Panel
500mA
500iWA
3
Notofier SDX-551 Smoke Detector
150uA
4506A,,
3
Notifier FDX -551 Heat Detector
150uA
450CfiNi
3
Wheelock NS-2475WFR Horn/Strobe
145mA
:435mA °:
62
Wheelock NH -24R Mini Horn
27mA
q1.674A'
Total Current
2V1
Total Internal 24VDC Power
5.0A
Battery Calculation
Battery (PS -1270 x 2) Power = 12V x 2.6Amps x 7Hr x 2units = 436.8VAH
Standby 24Hours Power = .5009Amp(Note) x 24Hr x 24V = 288.52VAH
In -Alarm 5 Minutes Power = 2.6Amps x .0833Hr x 24V = 5.20VAH
*Note: When System is on standby, only Control Panel, smoke Detectors and
Heat Detector are working. So:
Current=500mA+450uA +450uA= .5009mA
ave!
A
UP--
9
-UP-
A
--UP
fro"
(Ty P)
-UP-
-UP
UP -
k
r
4o' 0"
< TYP)
-UP-
L
Public Laundry Room
OFFICE
1
Mgr's Laundry Rm
Inl
n Rest Room
Storage I
STORAGE II
UP-
-UP -
TUKWILA GARDEN SITE PLAN
1
ca(e
5707L7 r T
CCT -41999 ez-