Loading...
HomeMy WebLinkAboutPP - 6155 SEGALE PARK DR C - CONTINENTAL MILLS - PERMITS AND PLANS6155 SEGALE PARK DR C ASSOCIATED PERMITS D19-0261 09-F-124 18-F-049 99-F-276 4 ift-4t SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 3523049115 Site Address: 6155 Segale Park Dr C Tukwila, WA 98188 Suite Number: Floor: Main Tenant Name: Continental Mills New Tenant? ❑ - Yes H- No Property Owner's Name: Continental MITIS Mailing Address: PO BOX 88176 Seattle WA 98138 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Manny Ornelas _ Day Telephone: 206-436-5301 Company Name: Washington Alarm Mailing Address: 2030 Airport Way S E-mail Address: permits@washingtonalarm.com City State Zip Fax Number: 206-322-7214 Contractor's City of Tukwila Business License number: BUS -0992857 Total number of new/relocated devices or sprinkler heads: 79 Valuation of Project (contractor's bid price): $ 24,000 Scope of Work (please provide detailed information): Multi stage project to relocate rack mounted Horn/strobes to ceiling due to fork lift damage. Also replacing power supplies for device sync. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A __,� ZE Signature: • 3IzI)A1Q Print Name: Manny Ornelas Day Telephone: 206-436-5301 Plan Permit App.doc 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: Fire Alarm: Address: 7'n 55 , Suite #: W(55 S4R ��C- Contact Person: Ual cal Pre -Fire: Permits: A n Special Instructions: _ Phone No.: ZSR IZ- 16/y Approved per applicable codes. nCorrections required prior to approval. COMMENTS: -740(.5 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: A n Occupancy Type: i Inspector,., ��5 Date: /(f7 k ¶ Hrs.: x"100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Configure Circuits Print Page / -swu�pn�e�vume�. . ' , � . � ��B��y��` . Project Name: Continental Mills. Standby Hours: 24 14 KNlGlIT Project ID: 15499-1 ` 4 Alarm Mins 5 < Prepo�dB�MannyOmo�a Derating Factor: 1.2 5495 Power Expander Calculati'. i Date: 3/5/2� ~ Voltage Drop Waming ' ` VerSion 09 ��` Threshold %• 10 =_=_- w ^ ^ '- Pane ID: 5495 5495P�e MaxC��n 3�Amp r, � . ~ � ' ^ ` ' ` ' ~ L000don1Power Supply 1 ll Volts* 24\��� _ _ __ _ _ - MnxPane Current: (�VAmpm — Current Draw Wire AWG Ohms Per Length(ft) Actual '��� Nmn%Dmp C�Circuit o�d- Standby Alarm & Type 1000 Ft. One -Way Ohms B]L 5495 5495 Pwr Module ‘1 0.075 0205 * 4" m ,' � ^* '' + "` * ;, ' NAC #1 5495 Circuit 1 0.000 0.000 #16 Stranded 4.02 95 0.76 19.73 3.29% NAC #2 5495Circuit 2 0.000 0.880 #16 Stranded 4:02 ~ 190 1.53 - 19.06 6.59% NAC #3 5495 Circuit 3 0.000 0.880 #16 Stranded 4.02 260 2.09 18.56 9.02% NAC #4 5495 Circuit 4 0.000 0.880 #16 Stranded 4.02 '''' 280 ' 2.25 18.42 9.71% Aux 5495 Aux Power Out 0.000 0.000 #16 Solid 4.02 0.00 20.40 0.00% Total Current .ps> 0.075 3.725 Tmo|�|annCunon��(Amps) ' Standby Time In Hours '. 24 . 0.083 Alarm Time In Minutes /60 (5 Mins) Total Standbv AH Required _1.8V0 0.310 Total Alarm AHRequired TotaI Combined AH Required ,` 2.11 ~ Wire resistances are based upon an ambienttempera ure of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required � '2.53 � Configure Circuits Print Page / Circuit Configuration [Project InromNnon Project Name: Continental Mills Prepared By: Manny Ornelas Project ID: 15499-1 Date: 3/5/2018 Ckt. Number. NAC #1 Panel ID: 5495 Ckt. Name: 5495 Circuit 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 -9.000 =--0.000-11 0.000^ 0.000 0.000 Totals 0 000 0.880 Ckt. Number: NAC#2 Panel ID: 5495 Ckt. Name: 5495 Circuit 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 " 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 ' 0.000 0.000 0.000 Totals 0.000 0.880 Ckt. Number: NAC #3 Panel ID: 5495 Ckt. Name: 5495 Circuit 3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000' 0.000 0.000 0.000 Totals 0 000 0.880 Ckt. Number: NAC #4 Panel ID: 5495 Ckt. Name: 5495 Circuit 4 ' Max Circuit Current: 3 AmpS Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 ' 0.176 ' 0.000 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0 000 0.000 Unused 0.000 0.000 ' 0.000 0.000 0.000 0.000 Totals 0.000 0.880 Ckt. Number: Aux Panel ID: 5495 Ckt. Name: 5495 Aux Power Out Max Circuit Current: 3 Amps ' Qty Device Current Draw Each Current Draw Total . Standby Alam1 Standby Alarm Unused 0.000 ' 0.000 ' 0.000 0.000 Unused ' 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Configure Circuits Print Page —Global Project Values. SII,EN"1 Project Name: Continental Mills Standby Hours: 24 1 <, TO KNICI IT Project ID: 15499-1 Alarm Mins: 5 1 ` Prepared By Manny Ornelas Derating Factor: 1.2 5495 Power Expander Calculations Date: 3/5/2018 Voltage Drop Waming Version 02 18.09 Q Threshold % . 10 Panel ID: 5495 Model: 5495 Power Expander 'Max NAC Current:" 3.0 Amps Location: [Power Supply 2 I Volts: 24 VDC ..,.. Max,Nanel Current:.6.0 Amps,. —.,„...d. Current Draw 0 Wire AWG t Ohms Per Length(ft) 4,, Actual ' Volts @ a Ckt.# Circuit Name'Standby Alarm & Type 1000 Ft. One -Way Ohms EOL °Drop 5495 5495 Pwr Module I 1 ., 0.075 0.205 NAC #1 5495 Circuit 1 0.000 0.880 #16 Stranded .. 4.02 : 95 .. 0.76 . 19.73, 3.29% NAC #2 5495 Circuit 2 0.000 0.880 #16 Stranded 4.02 190 1.53 19.06 6.59% NAC #3 5495 Circuit 3 0.000 0.880 #16 Stranded 4.02 k` 260 ' 2.09 18.56 9.02% NAC #4 5495 Circuit 4 0.000 0.880 #16 Stranded �� 4.02 ;., 280 . 2.25 18.42 9.71% Aux 5495 Aux Power Out 0.000 0.000 #16 Solid 4.02 0.00 20.40 0.00% Total Standbyturrent (Amps) 0.075 3.725 Total Alarm Current (Amps) a .. Standby Time In.Hours ;; 24 .. 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 0.310 Total Alarm AH Required Total Combined AH Required 2.11 Wire resistances are based upon an ambient tempera ure of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Multiply By The Derating Factor 11.20 Minimum Battery AmpHours Required 2.53 Configure Circuits Print Page ®II :,111 Circuit Configuration fProject Inforrtwuon Project Name: Continental Mills Prepared By: Manny Omelas Project ID: 15499-1 Date: 3/5/2018 Ckt. Number: NAC #1 Panel ID: 5495 Ckt. Name: 5495 Circuit 1 .. Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 ' 0.000 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 , 0.000 0.000 ' 0.000,. Unused 0.000 0,000- 0.000 - 0.000 0.000 0.000 Totals 0.000 0.880 Ckt. Number: NAC #2 ' ' Panel ID: 5495 Ckt. Name: 5495 Circuit 2 Max Circuit Current: 3 Amps Oty Device "' Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.880 Unused '0.000 0.000 0.000 ' 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 , 0.000 0.000 0.000 Totals 0.000 0,880 Ckt. Number: NAC #3 Panel ID: 5495 %.Ckt. Name: 5495 Circuit 3 - Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby . Alarm Standby , Alarm 5 System Sensor P2/PC2 Hom/Strobe (75cd) 0.000 0.178 0.000 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 ` 0.000 0.000 '' 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.880 Ckt. Number: NAC #4 Panel ID: 5495 Ckt. Name: 5495 Circuit 4 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Hom/Strobe (75cd) 0.000 0.176 0.000 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused ` 0.000 , 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.880 Ckt. Number: Aux Panel ID: 5495 , , Ckt. Name: 5495 Aux Power Out Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total ' Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused ' 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 ' 0.000 Totals 0.000 0.000 Configure Circuits Print Page ` —Global Project Values: SILENT Project Name:IContinental Mills Standby Hours: 24 14 KNIGHT Project ID: 15499-1 Alarm Mins: 5 Prepared By:IManny Ornelas Derating Factor:. 1.2 5495 Power Expander Calculations Date: 3/5/2018 Voltage Drop Warning Version 02.18.09 Threshold °I° 10 Panel ID: [5495 Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location: (Power Supply 3 I Volts: 24VDC ___ _Max Panel Current: 6.0 Amps ,. Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Dro Ckt.# Circuit Name Standby Alarm $, & Type G.. 1000 Ft. One -Way Ohms 4 EOL<,< ps 5495 5495 Pwr Module I 1 0.075 0.205 NAC #1 5495 Circuit 1 0.000 0.880 #16 Stranded ' 4.02 • 95 e 0.76 19.73 3.29% NAC #2 5495 Circuit 2 0.000 0.880 #16 Stranded 4.02 190 1.53 19.06 6.59% NAC #3 5495 Circuit 3 0.000 0.880 #16 Stranded " 4.02 260 2.09 18.56 9.02% NAC #4 5495 Circuit 4 0.000 0.880 #16 Stranded 4.02 280 2.25 18.42 9.71% Aux 5495 Aux Power Out 0.000 0.000 #16 Solid 4.02 0.00 20.40 0.00% Total Standby Current (Amps) 0.075 3.725 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 0.310 Total Alarm AH Required Total Combined AH Required 2.11 Wire resistances are based upon an ambient tempera ure of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Multiply By The Derating Factor 1.20• Minimum Battery AmpHours Required 2.53 Configure Circuits Print Page ea IH Circuit Configuration [Project Information Project Name: Continental Mills Prepared By: Manny Omelas Project ID: 15499-1 Date: 3/5/2018 Ckt. Number. NAC #1 Panel ID: 5495 Ckt. Name: 5495 Circuit 1 Max Circuit Current: 3 Amps Qty Device .. Current Draw Each :Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 .0.176 0.000 ^ 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 ' 0.000 ' 0.000 0.000 Unused "9.000 -. 0.000' '=0.000 " '"0.000'"' 0.000 '' 0.000 Totals 0.000 0.880 Ckt. Number: NAC#2 Panel ID: 5495 Ckt, Name: 5495 Circuit 2 ... Max Circuit Current: 3 Amps . .,, Qty Device Current Draw Each Current Draw Total Standby :Alam Standby r. Alarm 5 System Sensor P2/PC2 Hom/Strobe (75cd) 0.000 0.176 0.000 0.880 Unused 0.000 ' 0.000 0.000 '' 0.000 Unused 0.000 0.000 0.000 0.000 Unused `0.000 ''0.000 ' 0.000 ' 0.000 0.000 0.000 Totals 0.000 0.880 Ckt. Number: NAC #3 Panel ID: 5495 „ ., Ckt. Name: 5495 Circuit 3 Max Circuit Current: 3 Amps Qty Device ^� Current Draw Each ,, Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) .- 0,000 ' 0.176 i` 0.000 = 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 ' 0.000 ' 0.000 ' 0.000 Unused 0.000 0.000 0.000 0.000 ' 0.000 ' 0.000 Totals 0.000 0.880 Ckt. Number: NAC #4 ' Panel ID. 5495 Ckt. Name: 5495 Circuit 4 .. .. ... Max Circuit Current: 3 Amps ,. Qty Device Current Draw Each Current Draw Total . 4, Standby ' Alarm r Standby k, Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.880 Unused ' 0.000 0.000 ' 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused ' 0.000 0.000 " 0.000 ' 0.000 0.000 0.000 Totals 0 000 0.880 Ckt. Number: Aux �, Panel ID: 5495 ., Ckt. Name: 5495 Aux Power Out Max Circuit Current: 3 Amps Qty Device Current Draw Each . Current Draw Total Standby Alarm Standby Alarm Unused - 0.000 0.000 ' 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 ' 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000. ._ 0.000_ Totals 0.000 0.000 Configure Circuits Print Page —Global Project Values. LENT Project Name: (Continental Mills I Standby Hours: 24 %SI /I KNIGHT Project ID: 15499-1 Alarm Mins: 5 Prepared By: Manny Ornelas Derating Factor: 1.2 5495 Power Expander Calculations Date: 3/5/2018 Voltage Drop Warning Version 02.18.09 •Threshold % . 10 Panel ID: 5495 Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location:Power Supply 4 I Volts: 24 VDC ' _ Max Panel Current: 6.0 Amps - Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 0Drop 5495 5495 Pwr Module 1 0.075 0.205 NAC #1 5495 Circuit 1 0.000 1.760 #16 Stranded 4.02 95 0.76 19.06 6.59% NAC #2 5495 Circuit 2 0.000 1.232 #16 Stranded 4.02 190 1.53 18.52 9.23% NAC #3 5495 Circuit 3 0.000 0.880 #16 Stranded 4.02 260 - 2.09 18.56 9.02% NAC #4 5495 Circuit 4 0.000 0.880 #16 Stranded 4.02 280 2.25 18.42 9.71% Aux 5495 Aux Power Out 0.000 0.000 #16 Solid 4.02 0.00 20.40 0.00% Total Standby Current (Amps) 0.075 4.957 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 0.413 Total Alarm AH Required Total Combined AH Required 2.21 Wire resistances are based upon an ambient tempera ure of 72 degrees F. Because of the minimal difference between solid and stranded wi e no differential was made. Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 2.66 Configure Circuits Print Page MI Circuit Configuration [Project Information Project Name: Continental Mills Prepared By: Manny Omelas Project ID: 15499-1 Date: 3/5/2018 Ckt. Number: NAC #1 Panel ID: 5495 Ckt. Name: 5495 Circuit 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm ' Standby Alarm 10 System Sensor P2/PC2 Hom/Strobe (75cd) 0.000 0.176 0.000 1.760 Unused 0.000 0.000 0.000 "0.000+ Unused 0.000 0.000 0.000 0.000 Unused ^.* 0.000°M' ._0.000^ ^0.000 +'0.000a 0.000 0.000 0.000 Totals 0.000 1 760 Ckt. Number. NAC #2 r ' Panel ID: 5495 Ckt. Name: 5495 Circuit 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each ' Current Draw Total Standby Alarm Standby Alarm 7 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.178 0.000 . 1.232 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.232 Ckt. Number: NAC #3 Panel ID. 5495 Ckt. Name: 5495 Circuit 3 _ Max Circuit Current:, 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.178 w 0.000 0.880 Unused 0.000 0.000 0.000 0.000 Unused :. 0.000 '0.000 HI 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 - 0.000 Totals 0.000 0.880 Ckt. Number: NAC #4 Panel ID: 5495 Ckt. Name: 5495 Circuit 4 ` Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Hom/Strobe (75cd) 0.000 0.176 0.000 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 _.0.000 Totals 0.000 0.880 Ckt. Number. Aux , Panel ID: 5495 Ckt. Name: 5495 Aux Power Out Max Circuit Current: 3 Amps Qty„Device Current Draw Each Current Draw Total , ' Standby " Alarm Standby Alarm Unused 0.000 0,000 0.000 0.000 Unused 0.000 = 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0,000 0.000 . 0.000 0.000 _ 0.000 .. 0.000 Totals 0.000 0.000 Configure Circuits Print Page — Global Project Values: 44 SILENT Project Name: Continental Mills Standby Hours:1 24 KNICI I"r Project ID: 15499-1 ., - Alarm Mins:1 5 I Prepared By: Manny Ornelas Derating Factor: 1.2 5495 Power Expander Calculations Date: 3/5/2018 Voltage Drop Waming Version 02 18.09 Threshold % : 10 Panel ID: 5495 Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location: 'Power Supply 3 _ ,r1 Volts: 24 VDC Max Panel Current: -6.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual , Volts @ Ckt.# Circuit Name Standby Alarm & Type 1000 Ft. One -Way Ohms EOL �oDrop 5495 5495 Pwr Module I 1 , 0.075 0.205 NAC #1 5495 Circuit 1 0.000 0.880 #16 Stranded 4.02 95 0.76 19.73 3.29% NAC #2 5495 Circuit 2 0.000 0.880 #16 Stranded 4.02 190 1.53 19.06 6.59% NAC #3 5495 Circuit 3 0.000 0.880 #16 Stranded 4.02 ° 260 ' 2.09 18.56 9.02% NAC #4 5495 Circuit 4 0.000 0.880 #16 Stranded .. 4.02 280 2.25 18.42.. 9.71% Aux 5495 Aux Power Out 0.000 0.000 #16 Solid 4.02 0.00 20.40 0.00% Total Standby Current (Amps) 0.075 3.725 Total Alarm Current (Amps) Standby Time In Hours 24 . 0.083 Alarm Time In Minutes / 60 (5 Mins) ' Total Standby AH Required 1.800 0.310 , Total Alarm AH Required Total Combined AH Required 2.11 Wire resistances are based upon an ambient tempera ure of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 2.53 Configure Circuits Print Page 1 Circuit Configuration Protect lnrorma0on Project Name: Continental Mills Prepared By: Manny Ornelas Project ID: 15499-1 Date: 3/5/2018 Ckt. Number: NAC #1 Panel ID: 5495 ' ... Ckt. Name: 5495 Circuit 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 « 0.000 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 - 0.000 ""0.000 . 0.000 0.000 Totals 0.000 0.880 Ckt. Number. NAC #2 Panel ID: 5495 Ckt. Name: 5495 Circuit 2 ' Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total . Standby Alarm Standby ''Alarm 5 System Sensor P2/PC2 Hom/Strobe (75cd) 0.000 0.176 0.000 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 ' 0.000 0.000 0.000 Totals 0.000 0.880 Ckt. Number: NAC #3 Panel ID: 5495 Ckt. Name: 5495 Circuit 3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 ' 0.880 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 ' 0.000 Unused 0.000 0.000 0.000 0.000 0.000 , 0.000 Totals 0.000 0.880 Ckt. Number NAC #4 Panel ID: 5495 Ckt. Name: 5495 Clrcuit 4 Max Circuit Current: 3 Amps Qty - Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Hom/Strobe (75c0) 0.000 0.176 0.000 0.880 Unused 0.000 0.000 0.000 0,000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000. 0.000 0.000 0.000 0.000 Totals 0.000 0.880 Ckt. Number. Aux Panel ID: 5495 Ckt. Name: 5495 Aux Power Out Max Circuit Current: 3 Amps . Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 ' 0.000 0.000 Unused ' 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 120 -0" il� 19'-0" 41'-0" 30'-0" 30'-0" DRIVE UP RAMP OFFICE PLAN UR/RX (100)° OPEN OFFICE (E) ROOM ( E ) WAREHOUSE (E) OFFICE (E) WOMEN (E) COMPUTER (E) , SHOWER (E) OFFICE (E) OFFICE (E) LUNCH ROOM LT 7 CONFERENCE (E) vs (01 5-5- O K 17 r C ckg i S 2) \ \-, Dc ST � ►7j— A—A-- 12-SM ‘,./A - NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. ACCEPTED Without pt Comments As Notpd in Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City s . rkdards. Acceptance is subject to errors and o fissions which co not authorize violations of adopted s andards and ordinances. The res rs :? ity +u: :'� adequacy of design rests totVly with the des;oner. A} ditions, deletions or revisions to these draw rq-s after his date will void this acceptance and will require a r•submittal of revised drawings for subsequent approval. nal acceptance is subject to Feld test and Inspection by e Tukwila Fire Prevention Bureau. By: ,,, .�1 r te: �-(�-o�► 1Yil W1LA FtitE i3EPl1RIAJii11 Please call: 575.4407 end give this Job No.O���-I�-`S 3 i exact address for shut• i,wn or restoration approval O r AUG 1 247 north 1 4.1115 ACCEPTED Without Comments As Noted in Rea 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibil ty for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Pi:•event on Bureau. Date: 3.-t 1"/3 By; For phase, 3 3,,661:4-44 i, pro irk co , i'e-f-+ �i4 �1 �a ►'SSS s �, o�A„ti.5g ! ► d e v; cess sea, C,' GhA totida.ia ret-1-7-uJS. TUKWI A FIRE DEPARTMENT :--cat c ll 20 6-575 D7 and a6�:.t �. i givQ FIR"! c Perrli No. f = . shut- - t - OTICE complPteci, signed, Tukwila Fre ' a -Tr n _ 1ce- �St Ce `Ices:._- = Find _ -- irt a , telminzCufl of the Lest_ J E T1 LX IT F XIT P E stoZ7- E r,LEI E E x ilk 1 E STA[ f/ 1 E E E �7 E iso P E E STAGFA STAGE E E E E FPS=E E E FACP EPS FPS4FPSb E E h 'H E E E E E lE E (_ 11�) it n ate; z�F E� iH E ti .1E E 1i E E EvE \iE 1›:1r E E E r E Th E E �f_P FIRE ALARM SYN NOTE: ALL SYMBOLS MAY NOT BE USED 30 L LEGEND ON THIS PROJECT _ Y M`OL ,n SCR P €'r_ON Mc U !'`" _ i= F ALARM CON^O PAN- E [ .1[^ � ± nAr.jf i t._ Y FIRE ALARM POWER SUPPLY EiSTI G FF`F .r^ E MANUAL PULL STATION LitS..:T rNG - .),--:-- II H)ir ' r Ar - , 4^i"•F CEtI !a-" MOUNT Lr`L+ANG <4 OUN HORN I .. 1-_ — EXISTING EXIT NG { F � HOR'l ,` ,,,,_,u0,_ [ EX;S i ING - rLRRREVATlLd EiJ! .,. TION < =I SPEAKER .r.n - mak: E ]( ,} _Y, 'rt.xlhrvL t. .! —� CA'tULL4 — f- Y1r:1FCI AR i i=EN A'.. MOAN: 2_ — OE'.1i ADDRESS - LI iJ v'v t OR nrt LA., t _ fL—DENOTES^.J�x WO? s � M — �GENOiES DETECTOR :;[t ;+;JGL"I eti k S t -t N 1 u 1 i v 1 - SC it --Yl F- u HASE F V- F 1tF Via- A1H Y .., WI F M _ CM- [_ .NF 1- s! icCR Ent i-? ENFI OE rINF ntIAy i-4716 9 (S'i'r'i = 4 TWP - Am; AM 1-- RICAN WIRE Gy l ICII- r;.- Mit, .-1 PAIR tic �.`-'+A rFl• .t t_.r r 1- �I A=n COUNT CONDUCTOR yA1,YL:� _v� %Uvwt SSE ..Y r Y , 43! -Y. ii EMS PAR r-1 r' _ 4 . r1 I P HI* +=.4. ._ . I._. .._ ..-.. 1k:RL - 1fl F L - PI I`eL.L ;]'Axe IM( TI -I R- t� - i rY9�I? ,14. I: !il-ir [S $ CC CABLES (iF Ok.i Eu � ONLY I ;ABLE NEE:EDI - - I„a.; aiyt, . I I No I-3 if :AAP -1 !AWE t: t.:F 14 .;-., ION H: :!?I`+I. �.i?1.-. III St C: SII INAti I Y. I INF- CI:tlCUIi / FIRE ALARM PLAN INVSCALA 16. r't f, t �i A r f � GENERAL i� 1 I 1_ SCOPE OF "'OP' T(Rt_E� STAGE PROJECT Ti R�_LOCAT !`%!sTIN i RACK MO1INTEn HORNS RCL0[_^ ON TOG'ERHE^�n B EM:_ i- P fJ:AC inW R SUPPLIES FORSYNi _ 2_ il-1ESE D rl iYtlivV� EXACT 111M `tP ^'t�AA a;c1, AT - REFER 17 T� ' A 'T ^T al;f [j At;rin!��.-• FOR JIACRAMMA IC. REFER k L I r'C ARCHITECTURAL F TURA DRA(7IiY S }A[�TArr AT?; ;(.r li rMl [� iAiIT` NEC A,?f_YiA 7i Ai t1T LM Ar.rc-t A rC `�^:`' �L ( C f !tom -1 IYt •. A - AND ti Ilii f Cr �t ES Tl t ^ Ar At H t fT�}r-}r. [fl; T,Rk IP` ii ['°Fc't..!'�'.`1`r F Iii ' � r?_irliti�CJ E AL A!ORIT t4.TVtill'-? ! WIRING 4( D. tC Z O THESE NS lr fir" TIC - ACTLIA ,{:IRE 1 TIONS MAX `t_ fYF EttVi3 i.,1�Ei'1TE%1 v1� it4�--C e i:�'.IV� i� -�1-M'1 r` LOCATIONS �- FROM Tr_i ^r PLANS. _ _r••. \r _ _ _ �,rn^ j- AS ACTUAL r' It .x0.:s•c GtF ROM ESL SPLA !1 4i 4N[ [' S '{ B RE K } Lt! 1 irl4 I•r�a J+`lt ii}y_`aL i 1�2J. i la. �`v ...i:yiE"4� [ BF t�E��i LKIYt L..r r I��� t� Y F C t h._ U�.1!L I"_ice? n i� TRL1CTiON L OND i t:- AI OW A. TO M _M+I1 E IRAs t'11 THROUGH AREA T 'C1 ! 1 "' � R dt• _ ,f --r- -[--I,. T +iP r� A;� 'L:4 -y. .-�,..r 1..JlV J�.i,.siT_1.t� Lor( AND TO tllik�Y-1',{�� = L lL 1'v E.., . y - CL^ARATIO(,N 4;11A`SS AN FRIE WALLS_ THF USF CIF RACEWAY IS PERMITTED `S iy rr''4. Yr rliLr,� t�� y-ttii.! r14it— 'a.a�s_ .iIL l.!�i� .�_ A -'-1ivL;fYA: IS .,xr:.k!tLf AS - AS NO s a:l=! -r "`I T = - .,! THE SAME RACEWAY_ k'� t HIGHER Er t CCE S A, r ;. ,F- ACr 'T L�.i�d'+.� `i �i i iii �� OR E'tlV r't Clt Yl_i! [.-Vi tit �_ � t'.:-1_ IN �: 1xYel_ t.1 -i4 'Y'�t'!4_ 5_ FIRE RATINGS S rl I BE MY1:'N C.NED FOR ALL PENETRATIONS THROUGH F1RE-Re?ED COtNSTRLIC ICN. 6. POWER FOR AIL FIRE ALARM PANELS AND FIRE Ar r - M PJ WE_-SUPPLIES MUST RF �P-ROVI,^}_i-; 4B;( tDEFDICAT �R€ BRANCH C 4Ct tT -_ f5'TIO:-"..1 ,C THE E` ANC i �:li it iLs Lt BY A L'C Lti\Jflt Els AC CIRCUIT_ `JFF. T�k L. i_!Ji-Pt`v Et �i 1t1= s��:"•�i 41�H CIRCUIT BRF KER SHALL BE PERMANENTLY IDE NTI FIED THF CO-N TRnr UNIT AND SHALL HAIR A RED MARKING IN ACCORDANCE WITH NETA 72_ F1�1 F -1"i4Tr._D AND iPCWER- L ttTrLi CIRCUIT `'tC M :.rT SEPriR1 �•D 1i5 CABINET. ArI POWER -LIMITED CIRCUIT WIRING MUST REMAIN AT LFAST 0_25" AWAY FROM.. ANY rYrn4r R-LrV}IED ^tr�-=UIT WIRING_ - ^ l _^M nn rAlf POWER -LIMITED AND NONPOWER-LIMITED rt_OEF LtMlED CIRCUIT 'WIRING UST� ENTER AND EXIT TF:C CABINET Ti -ROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. WHEN VTI' !ZING CLASS "r" CI^C.r I_..I.TC CEPARATE OUTGOING AND RETURN CONDUCTORS Cr CLAS "A" CIRCUITS R° A MINIMUM OF in"WHERE RUN VERTICALLY uRT[CALLY MD 48" i' -'ERE RUN Irl: IZO;;!T?;`L I !r 11-,1,1 4" tit_I NCTt_F SHIELDED H:_[r=i�:A --!�—D r4ApL[ TIE SHIELDS ELv TS A r LiA"r tir-,=. J11 T €-',.- : 4 t _ AND !► Ui ATF ; Li - Aft FIRE AI ARM CABLING sHAL1 RF AC:CEPTABL F TO At1 i ± 1 sYL 1 €^ rt FOR THE INI E -- r} PURPOSE_ 11. SI4OKF 0!E_ FCkORS SHALL ri COMPLETED.. ttr4 AlAT r Ar t Ar'MA AL14,! Eu+i i STALLED U tiTII AFTER " E CO -NC RUCTlON Cl FAN-UP 12_ OCAT t SMOKE DETECTORS AMY,kIM1M nvr THRFF fFEET FROM MECHANICAL r- FUSE WAr M - OI IA -1 ED SMOk' DET CT�'1R SF.iA1 B LOCATED MINIMUM OF t. � 1 t.i .,_�1_ �Yr -iY:L'*-s iY. _ter WOKE V_ir�L. Ji'.J �.: IT1LE BF A -�:I4�i I.Y:L rY, OF n AND + 19" ^ 4!r +rr zl 6- ?A M -t � t � r .—T[. uN� a ! O,• ! t 1t i'f� .`r r 1 ° t , �` !� FROM - _ `L IY-4•Vt IEE, .. v C UL{LL__rl r-4 `I ;r - e' i� - �� y �}r Y — Mint INTM (�N CEILINGS ANn 1•`,s -T t , r,= (1TT:"lkt` CF yt_ xti i=- G ISS 5 ;�i'L; :L'S= ,..,v�1ae'=L1 4_::`t I'tlti..i 4YL)i �iY C t�-J :Y�� vi }".?:_ tiv .:�.Jt�_ 1 Z FEW r4 r: ;- I``y;^f:,A. 7^A. F ts; r -•t r- NOTIFICATION !AFrzTCIRCUIT 4.• 1 K NI .I?- (' 1� ?� 1 I ( i E6 JYI � SYNCHRONIZATION �:i t: c_J. I�Kl:vt�Y L:� ^L � YI.�` � i -YJ 41�IL±'k IL1Y :1 •r_lt':i'iL �-Iii Lr till._._ PROVIDE A' L FEC ,FED SYN. -0 Mn [ EIS_ PROVIDE = tLii-SY C Mn vL Lt - E CI %Nr-- 4 �I Ari -UN .ALL s INc- MnDULES_ Crr VERIFY ALL tr .SFI .ii7E�TA ��� .�L,_ iL•Tf SETTINGS ETT GS C- NOTIFICATION' hP P! A WITH F.RE APV CON RYTOR ..r. UPON COMPLETION F f[R ALARM cYSTEM INSTALLATION.... AND ROG_ RMJIN. THF : T LL,IYG CONTRACTOR (MALL PuRFvR FINAL TESTING OF THF� ENTIRE SYSTEM a PER �r A '+A r� �: ^t- AND /�1 '\ ^('c :`,IATr- R PERFORM �; / A r'A' !?�� PER ALL : ;PPLIC ABLE Ct)DE_S, AND SHA' i CCORDll A F Al44D PERrO \ A r'4- L FIRE F14 SYSTEM SPE �.T`ON PROVIDE OFF -S 1TE MONITORING AS REQUIRED BY THE INTERNATIONAL tJA tf rL!RE CODE LE -C ION an7 -]�, D :1;E (OCAI At' jR ;f i-iA is{r. !F r}r.(4iSr11�+ 4/ A: -J LS.r{4.1 'i .lvi f � L1 TI, �J`�.r:'4L r�t!r t.r lit t FA�Olt; t.: t._ll i..iL EL tt�l t_ 17. [NSW IG ^�aNTRA1R SHALL, iYS,..xFC_ALL.r LABEL ALL __ IV:TI TrG DEVICES AND NOTIFICATIONAPPLIANCE ,IRCUt T r_ND OF LINE (WHEN WIRING CLASS "B"). THF SE LAPELS JH,"A-1!—t Fir_ IN RAF= PRIOR Tnv START—UP AND TESTING_ shop drawings created by. 5794 W. 4600 So. Hooper, UT 84315 Office: 801.985.0410 www.unicod.net PAID HAR 201Z TUKWIIJA FIRE %ys?` TUKWILA CONTINENTAL MILLS GALE PK DR. 1.0 TUKWILA, WA FIRE ALARM PLAN DRAWN CWS UNICAD JOB ij17792 PRtDY B HAWS ..LECKE -- WCET ,ATE 1/10/ 2018 REVISION 0 cr.v E FA -1 • . - - _ 7_ CN1 LL 0 CN LLJ LLJ (f) LLJ LLJ (J) LLJ 0- Tamperswitch 0 Row switch Ti Horn strobe - Manual pull - TEO Annudator panel mr) Control panel Exterior bell ® Smoke detector X Strobe Washington Alarm Inc 1253 S Jackson St Seattle, WA 98144 (206)328-3288 contact: Neal Rider Qs) 11•11111111111111M1111113.11.11111•0110MOMINIMININE=111•11•11111, CD LFjC) ji ( E ED.' n - - • ;". ./F,„ • /. D De a 0 a LoL c7A1-ECL 0 ••••••••• 7 c act_ fr, 0 0 0 a 0 0 \,\ 0 0 a 0 EDL cE.0 L --- P 0 a L • 0 a 0 a 0 0 0 0 0 0 a 0 L E 0 I-- 0 0 1 t' JL 1 I / I / / __ • RgLARM- - +Mr REVISIONS: SEGALE BUSINESS PARK TUKWILA, WASHINGTON (206) 575-2000 1TTLE: Continental Mills 6155 Segale Park Drive "C" DESIGNED BY: PROJECT NUMBER: DRAWN BY: SN CHECKED BY: SCALE: 1/16= r —0" CADD ALE: ALARMEAST.dwg ISSUE DATE: DATE: 8/13/99 DRAWING NUMBER: SHEET: 1 - - . TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job No. and exact address for shut, down or restoration approval. ACCEPTED Without Comments As I\10ted In Red Per The Attached Letter se ans have been reviewed by The Tukwila Fire t- on Bureau foriconformance with current city standards. Acceptande is subject to errors and uniisori whklfdo not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the desgner. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings forsubsequent approval. Final acceptance is Subject to field test and inspection by The TukwiLa Fire Prevention Bureau. Date: cAkz:\ By: 5 (0 • - - - - T - - _ _ 7_ • - - - , - FLE -f - - - - - - - - _ - • 5. - ()es* cif) 0-- CJasi- tM1E WO -0 Noriilp We. 4shys,5_.(G) Notit, C.J•174Sdle.0--0— No rill CJ /*SE-. (.3') r-iilects+ G...)ifSe. (I) 0-0 IfSft I 7. ierafP C'S) t -AC E ri for CJ H-sE r We) o FrxcE [1)o*. r•.Ea-S+ (A) ftE-CE ffoye r 12.) F Deiecit) r E.Iec ic .00 Pi Ptloo e Fc.i3 I. (S) C.Jt-t. S E_ tJez-ks Cd) tiS s NSE_ s (3) 0•FFXCS (3) 1 PC. TELCO 0- Tamper switch -<>0 Row switch Ed Horn strobe Op Manual pull ItE3 Annuciator pane rfo Control panel 2 Exterior bell ® Smoke detector )( Strobe @) -c7i— ptoiKe r Washington Alarm Inc 1253 S Jackson St Seattle, WA 98144 (206)328-3288 contact: Neal Rider 1 fiE3 a J a a a a 13 a D Drij1,4E.oL, DS CI ral L.JEDL— CN LL Li LLJ (f) LLJ LLJ Cf) LLJ T 1' •t • • a t FIRE ALARM - _ r •._- _ _ . - - - - . - - _ -E--- • - • _ _ _ - - - - - •_-- - - - _ - • - _ - _ - - REVISIONS: M11•11116 SEGALE BUSINESS PARK TUKWILA, WASHINGTON (206) 575-2000 TrTLE: Continental Milis 6155 Segale Park Drive "C" DESIGNED BY: PROJECT NUMBER: DRAWN BY: SN CHECKED BY: CADD FILE: ALARMEAST2.dwg ISSUE DATE: SCALE: DATE: 1/16=1'-0" 8/13/99 DRAWING NUMBER: _ SHEET: 0F:2 • gr - - - • - - . - - - , _ - - - *77 • - - . • _7-- , Tr_