Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 4708 SOUTHCENTER BLVD - THE BOULEVARD AT SOUTH STATION - PERMITS AND PLANS
4708 SOUTHCENTER BLVD ASSOCIATED PERMITS 18-F-198 18-F-199 09-F-001 MIS SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 2223049003 Site Address: 4708 SOUTH CENTER BLVD - BLDG H Suite Number: Floor: Tenant Name: THE BOULEVARD AT SOUTH STATION Property Owner's Name: BRE MG BLVD -SOUTH STATION New Tenant? ❑ - Yes X No Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: SCOTT JERKE Day Telephone: 253-248-2004 Company Name: SMITH FIRE SYSTEMS Mailing Address: 1106 54TH AVE E, TACOMA, WA 98424 City State Zip E-mail Address: SJERKE@SMITHFIRE.COM Fax Number: 253-926-0726 Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 1187 Scope of Work (please provide detailed information): REPLACE EXISTING FACP - LIKE FOR LIKE PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR RIZE Signature: PAIL OCT 10 2818 10/10/18 TUKWILA FIRE Date: Print Name: SCOTT JERKE Day Telephone: 253-248-2004 Plan Permit App.doc 1/2/13 TFD FP Form 8 'WPM SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 2223049003 Site Address: 4708 SOUTH CENTER BLVD - CABANA Suite Number: Floor: Tenant Name: THE BOULEVARD AT SOUTH STATION New Tenant? ❑ - Yes X No Property Owner's Name: BRE MG BLVD -SOUTH STATION Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: SCOTT JERKE Day Telephone: 253-248-2004 Company Name: SMITH FIRE SYSTEMS Mailing Address: 1106 54TH AVE E, TACOMA, WA 98424 City State Zip E-mail Address: SJERKE@SMITHFIRE.COM Fax Number: 253-926-0726 Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 1187 Scope of Work (please provide detailed information): REPLACE EXISTING FACP - LIKE FOR LIKE PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER WAUifIIORI717 Signature: Print Name: SCOTT JERKS Plan Permit App.doc 1/2/13 PAID CCT 10 2018 TUKVVILA FI Day Telephone: Date: 10/10/18 TFD FP Form 8 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical Permit No. Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 2 Z. Z 3Oy 9003 Site Address: 4/708 T t G/i?J T 2IL g WO. 7L law l A7 WA Suite Number: 4/NBA—kW/I Floor: Tenant Name: PAR -) 2- PLAGE. RV Dili Ul b6TS New Tenant: ❑ Yes 1,8,..No Property Owners Name: AA (r) p2a p o Ti i.S Mailing Address: )O S©S a.C.soT0 tml lU at. #30 N 1p, , G� A 92111 J CityState Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: / J4 J i2 ibbirOS Day Telephone: .2061- S tic --031 1 Mailing Address: /6,7 I,cJ/4- /4/11 4.17O/li AL i4 wit .9.0a1 City State Zip E -Mail Address: £ Ui J abbtli F=1 t2,z—qU; , O Fax Number: 2S 3- r7.3 S qq 7 ELECTRICAL CONTRACTOR INFORMATION Company Name: F I Riy Ort.)iy, , A)6., Mailing Address: I'(97 w.isi-1/A161-Tok.) 13WTh, Contact Person: FVAlyIZc+6h i e) Aw.c>vA ,,,JA 9800) City State Zip Day Telephone: 2>-o(/ E -Mail Address: I_vA rJ i2cbb i n) e3 Fi t2 0I ,O,�ln Fax Number: ZS -3 _. )3 S- 9 / 7(' Contractor Registration Number: i— ► 2ia Ol ,l`O9CI k W Expiration Date: 4j--)6 - noQ Valuation of Project (contractor's bid price): $ 9 r200 Scope of Work (please provide detailed information): 1 N5Ti41114 T1 D _.) d ► i t.J l_3 l—, t A(_,A2rN1 Will service be altered? ❑ Yes No Adding more than 50 amps? ❑ Yes or No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel D Tenant Improvement gLow Voltage ❑ Generator Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: "41 Puget Sound Energy ❑ Seattle City Light H Apphcations\Forms-Applications On Line \4-2007 - Electncal Permit Application doc bh Page 1 of = RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages. pools. spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm. furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter/mast repair $65.00 ❑ Low voltage systems $55.00 (alarm. furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES O Temporary service (residential) $58.00 ❑ Temporary service (generator) S75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I I -LAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: dk/'L' Print Name: !?b (-71ZC24 I of Mailing Address: / 0 7 /A-4145/1-11/06,5-0/0 L --\.) b. Date: / Day Telephone:Zn(O'�f%5 03 A Ltc1A) A Q8 ') City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H Applications Fonns-Ap phcaz:rs On Ln 1 .a'7 - Eleencal Perm I Apphcanon doc bh Page 2 of 2 SMITH FIRE SYSTEMS, INC. 1106 54TH AVENUE EAST, TACOMA, WA 98424 THE BOULEVARD AT SOUTH STATION CABANA 4708 SOUTH CENTER BLVD TUKWILA, WA 98188 PARCEL# 2223049003 SFS PROJECT# FAI81 10 OVERVIEW THE SCOPE OF THIS PROJECT IS TO REPLACE TO REPLACE THE EXISTING MIRCOM FX -350 FIRE ALARM CONTROL PANEL WITH A NEW MIRCOM FX -350 FIRE ALARM CONTORL PANEL. PAID OCT -9 201R T�U1�KWILAFIRE R E CONTENTS I . MIRCOM (FX -350) FIRE ALARM CONTROL PANEL 2. DURCELL (DURA I2 -8F) BATTERY DURACELL SLA Batteries ULTRA Purpos) PROJECT NAME: CATALOG # FIXTURE TYPE NOTES Battery Volis Capacity Ah (20Hrs) Dimensions trilfitxH Inches) Terminal Type Group Size Weight (Lbs.) DURA12-0.8WL 12V 0.8 3.78 , 0.98 2.4 WL - 0.77 DURA12-1.3F DURA12-2.3F 12V 12V 1.3 2.3 2.9 3.82 6.97 3.11 1.69 2.28 F1, T1 - 1.37 1.38 2.64 3.9 L F1, T1 2.04 DURA12-2.9F 12V 2.2 F1, T1 - 2.36 DURA12-3.3F 12V 3.3 5.28 I 2.64 2.63 F1, T1 I - : 3.18 - DURA12-3.3F2 12V 3.3 - RAYA12-4F 12V 4 3.54 3.54 3.56 2.76 2.76 2.77 4.21 4.21 3.94 .4. F1, T1 - - DURA12-5F 12V 12V 5 5 F1, T1 F2, T2 - - - - DURA12-5F2 DURA12-5.1A 12V 5.1 5.51 1.89 4.21 F1, T1 - 4.6 DURA12-5.SF RAYA12-7F 12V 12V -i- 5.5 7 3.54 5.95 F 2.76 2.56 - 3.98 1 3.94 3.94 - - F1, T1 _ F1, T1 , - - DURA12-7F 12V 7 5.94 2.56 - DURA12-7F2 DURA12-8F 12V 12V 7 5.94 2.56 3.7 F2, 72 - 8 5.94 2.56 3.94 F1, T1 - - DURA12-8F2 12V 8 5.94 2.56 3.94 F2, T2 - - DURA12-9NB 12V 9 12V 9 5.95 5.95 2.56 2.56 3.9 1 3.94 ,---- NB 1- F2, T2 - - - DURA12-9F2 DURA12-10F2 _ 12V.._1. 12V 12V 10 5.95 2.54 4.38 F2, T2 - 7.5 DURA12-11NB DURA12-12F2 11 12 5.28 5.94 3.15 3.9 6.5 3.98 - F2, T2 ' - - 10.1 - DURA12-12F 12V 12 5.94 3.86 3.86 F1,T1 . - DURA12-14F2 12V 14 18 5.94 7.13 1 3.86 3.98 F2, T2 , - 8.91 DURA12-18F2 DURA12-18NB 12V 12V T 3.03 3.03 6.93 6.57 F2, T2 i , - - 18 7.13 6.5 1 6.57 4.92 6.5 NB, 1 NB, .1 ' C - 12.43 20.7 27.3 DURA12-26NB 12V 26 DURA12-35C 12V 35 7.72 1, 5.16 DURA12-44C/FR 12V 46 7.8 6.54 6.85 C , - 38 DURA12-55C/FR DURA12-80C/FR i_ 12V 55 12V 80 9.02 10.24 5.43 6.65 6.65 I 8.35 8.46 - C - - 42.1 74.6 DURA12-100C/FR 12V 100 12.09 8.46 C DURA12-140C/FR DURA4-4.5F2 12V 4V 140 13.43 1.85 6.81 11.3 --I C . - - 108 4.5 1.3 1.85 3.98 F2, T2 - 1.4 DURA6-1.3F 6V 3.82 0.94 1.45 - 2.28 F1, T1 4- - 0.715 DURA6-2ST 6V 2 1.69, 2.99 ST F1, T1 - - 0.75 1.26 DURA6-2.9F 6V 2.9 2.6 1.46 .i. 3.82 DURA6-3.3F RAYA6-4F DURA6-5SP 6V 3.3 6V 4 6V 5 5.28 2.76 2.6 -'r 1.34 4_ 2.64 4.13 4.53 ---1 F1, T1 - 1.65 1.85 2.6 F1, T1 SP - - 2.09 DURA6-5F 6V 5 2.76 1.85 4.21 F1,T1 - - DURA6-7.2F DURA6-8.2F 6V 6V 6V 7.2 8.2 10 5.94 3.9 5.94 1 j 1.34 2.24 1.97 3.68 4.53 L 3.98 L 3.98 3.98 F1,T1 - 2.43 F1, T1, F1, T1 ' - 3.8 DURA6-10F - 4.851 DURA6-12F 6V 12 5.94 5.94 1.97 1.97 F1, T1 - 4.602 DURA6-12F2 RAYA6-14T2 6V 12 F2, T2 6V 14 4.25 2.8 2.8 3.37 5.51 -T- 5.51 6.37 H - 6.24 DU RA6-14A 6V 14 4.25 6.25 F1 (-) F2 (+), T1 (-) T2 (+), FP ' F2, T2, - _ 6.16 16.64 DURA6-42F2 6V 42 DURA6-42NB 6V 42 6.34 3.43 6.42 NB, J , ; _ 16.62 DURA6-200C DURA8-3.2F 6V _ 200 8V 3.2 12.05 5.28 -1- 6.65 1.44 .. . 8.63 2,48 C . , F1, T1 - - 1.65 Visit batteriesplus.com for warranty information 0 2017 DURACELL, Bethel, CT 06801. Duracell is a registered trademark of Duracell U.S. Operations, Inc., used under license. All rights reserved. Banerries+Bubs. 0 ACCP Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire ',revention Bureau for conformance with current City ander is. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions ctr revisions to these drawings after this date will void this acceptance and will require a resubmittal n° rvier= drawings for subsequent approval Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 10-I-7 I By: JKWILA FIRE DEPARTMENT ease call 206-575-4407 and ,Av2 this Fire Permit No. -F-1Y% id id exact address for shut - own or restoration approval. e Q DURACELL SLA Batteries ULTRA u eneralPurpos) PROJECT NAME: CATALOG # TYPE FIXTURE ------- -- NOTES Visit batteriesplus.com for warranty information 0 2017 DURACELL, Bethel, CT 06801. Duracell is a registered trademark of Duracell U.S. Operations, Inc., used under license. All rights reserved. Banerles+ &fibbs, Battery Votts Capacity Ah (2OHrs) D;mensions (_xWxH inches) Terminal Type Group Size Weight (Lbs.) DURA12-0.8WL 12V 0.8 3.78 ! 0.98 2.4 WL- 0.77 DURA12-1.3F 12V 1.3 3.82 1.69 2.28 F1, T1 - 1.37 DURA12-2.3F 12V 1 2.3 6.97 1.38 2.64 F1, T1 - 2.04 DURA12-2.9F 12V 2.9 3.11 2.2 3.9 F1, T1- 2.36 DURA12-3.3F 12V I 3.3 5.28 I 2.64 2.63 F1,T1- 3.18 DURA12-3.3F2 12V 3.3 - - - - - - RAYA12-4F 1 12V 4 3.54 2.76 4.21 F1, T1 - - DURA12-5F 12V 5 3.54 2.76 4.21 F1, T1 - - DURA12-5F2 12V 5 3.56 2.77 3.94 F2, T2 - - DURA12-5.1A 12V 5.1 5.51 1.89!L!4.21 F1, T1 - 4.6 DURA12-5.5F 12V 5.5 ! 3.54 2.76 3.98 - - - RAYA12-7F 12V 7 5.95 2.56 i 3.94 F1, T1 - - DURA12-7F 12V 7 5.94 • 2.56 3.94 F1, T1 - - DURA12-7F2 12V 7 5.94 2.56 3.7 F2, T2 - - DURA12-8F 12V 8 5.94 2.56 3.94J F1, T1 - - DURA12-8F2 12V 8 5.94 2.56 3.94 F2, T2 - - DURA12-9NB 12V 9 5.95 2.56 3.9 NB, J - DURA12-9F2 12V 9 5.95 2.56 3.94 F2, T2 - - DURA12-10F2 12V 10 5.95 2.54 4.38 F2, T2 - 7.5 DURA12-11NB 12V 11 5.28 3.15 1 6.5• 10.1 DURA12-12F2 12V 12 5.94 3.9 3.98 F2, T2 - - i DURA12-12F 12V 12 5.94 3.86 3.86 F1, T1 - - t DURA12-14F2 12V 14 5.94 3.86 3.98 F2, T2 - 8.91 DURA12-18F2 12V 18 7.13 3.03 6.57 F2, T2 - - DURA12-18NB 12V 18 7.13 3.03 6.57 NB,1 - 12.43 DURA12-26NB 12V 26 6.5 ! 6.93 4.92 NB, 1 - 20.7 DURA12-35C 12V 35 1 7.72 5.16 6.5 C - 27.3 DURA12-44C/FR 12V 46 7.8 6.54 i 6.85 C- 38 DURA12-55C/FR 12V 55 9.02 5.43 8.35 - 42.1 DURA12-80C/FR 12V 80 10.24 6.65 8.46 C - - DURA12-100C/FR 12V 100 12.09 6.65 8.46 C - 74.6 DURA12-140C/FR 12V 140 13.43 6.81 11.3 C - 108 DURA4-4.5F2 4V 4.5 1.85 1.85 3.98 j F2, T2 - 1.4 DURA6-1.3F 6V 1.3 3.82 0.94 l 2.28 F1, T1 - 0.715 DURA6-2ST 6V 2 1.69 1.45 2.99 ST- 0.75 DURA6-2.9F 6V 2.9 L 2.6 l 1.46 3.82 F1,T1- 1.26 DURA6-3.3F - 4- -- 6V 3.3 - 5.28 1.34 2.64 F1,T1 1.65 RAYA6-4F 4.13 F1,T1 - 6V 4 2.76 1.85 - DURA6-5SP 6V 5 2.6 2.6 4.53 SP - 2.09 DURA6-5F 6V 5 2.76 1.85 4.21 F1,T1 - - DURA6 7.2F 6V 7.2 5.94 1.34 3.68 F1, T1- . - 2.43 DURA6-8.2F 6V 8.2 3.9 2.24 4.53 F1, T1, - 3.8 DURA6-10F 6V 10 5.94 1.97 3.98 F1, T1 - 4.851 DURA6-12F 6V 12 I 5.94 1.97 3.98 F1, T1 - - DURA6-12F2 6V 12 5.94 1.97 3.98 F2, T2- 4.602 RAYA614T2 6V 14 4 4.25 2.8 5.51 H - 6.24 DURA6-14A 6V i 14 4.25 1 2.8 5.51 F1 (-) F2 (+), T1 (-) T2 (+), FP 6.16 DURA6-42F2 1 6V 42 j 6.25 3.37 6.37 F2, T2 i - 16.64 DURA6-42NB 6V 42 f 6.34 • 3.43 6.42 NB, 1 - 16.62 DURA6-200C 6V 200 ; 12.05 6.65 8.63 C - - DURA8-3.2F 8V 3.2 5.28 1.44 l 2.48 F1,T1 - 1.65 Visit batteriesplus.com for warranty information 0 2017 DURACELL, Bethel, CT 06801. Duracell is a registered trademark of Duracell U.S. Operations, Inc., used under license. All rights reserved. Banerles+ &fibbs, ACCE TED 0 Without Comments © As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City :r:,ndards. Acceptance is subject to errors and ,:,iissions which do not authorize violations of adopted :andards and ordinances. The responsibility for the ,,dequacy of design &rests totally with the designer. ;additions, d' etions or , evisions to these drawings after this date will void this ..icceptance and will require a resubmittal of revised drawings for subsequent approval Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: I u- 3- l By: y :Ki'r ILA FIRE DEPARTMENT ',east c:741206-575-4407 and ii � re ��....�� F_.. L�p��� rn t No. Fire. sfor shut- :: v ri or restoration approval. 0 A B C D E F H 1 2 3 4 7 8 9 10 FIRE ALARM WIRE LEGEND DESIG. DESCRIPTION A 16/2 FPLR INITIATING CIRCUIT WIRING B 14/2 FPLR INDICATING CIRCUIT WIRING C 18/4 FPLR ANNUNCIATOR CIRCUIT WIRING D 14/2 FPLP DUCT DETECTOR OR DOOR HOLDER POWER WIRING E AWG-16-THHW FOR DIRECT BURY/WET LOCATION KEY LEGEND AND COMPONENT LIST SYMBOL DESCRIPTION QTY PART # MANUFACTOR MOUNTING SPEC Sidewall FIRE ALARM CONTROL PANEL 1 FX -350 -60 -DDR MIRCOM WALL TOP @ 66" i FACP I pert FIRE SIGNAL EXPANDER 11 1.1 (3Y min 1.37 (4A maximum m 8.) mum m ft.) fr,2,4 Finished floor WALL TOP @ 66' FSE I //7/////////// ANNUNCIATOR 1 RAM-300LCDR MIRCOM WALL TOP @ 66" I ANN 1 TRANSMITTER FIELD VERIFY LTRAN I SUBSCRIBER TERMINAL UNIT FIELD VERIFY 1 STU I >111 HORN WALL @ 80"-96" fil MINI -HORN WALL @ 80"-96" CE BELL 1 MB -G10 -24R WHEELOCK OUTSIDE WALL @ 10' STROBE 3 ZNS-MCW-FR WHEELOCK WALL @ 80°-96" X WEATHER PROOF STROBE 1 RSSP-2475-FR WHEELOCK WALL @ 80"-96" WP X HORN -STROBE 2 ZNS-MCW-FR WHEELOCK WALL @ 80"-96" 0 CEILING MOUNTED HORN/STROBE CEILING 0 CEILING MOUNTED STROBE CEILING CHIME FIELD VERIFY C O SPEAKER WALL @ 90" JO JUNCTION BOX FIELD VERIFY DOOR HOLDER FIELD VERIFY I DH 1 DOOR STRIKE FIELD VERIFY I DSI F MANUAL PULL STATION 2 MS-701DU MIRCOM WALL@ 48" ® AB SMOKE DETECTOR ABOVE CEILING ABOVE CEILING OR IN DUCT SMOKE DETECTOR 6 MIX -3100 MIRCOM CEILING - 3' FROM AIR DEFUSER m BL SMOKE DETECTOR BELOW FLOOR BELOW FLOOR ® 135° FIXED TEMP HEAT DETECTOR 4 MIX -3300 MIRCOM CEILING OR 194° RATE OF RISE HEAT DETECTOR CEILING OR 135° RATE OF RISE HEAT DETECTOR CEILING 1940® 194° FIXED TEMP HEAT DETECTOR 2 MIX -3300 MIRCOM CEILING G> LINE TYPE HEAT DETECTOR FIELD VERIFY wF WATERFLOW SWITCH RISER PIPE Ps PRESSURE SWITCH RISER PIPE TAMPER SWITCH GATE VALVE TS JB JUNCTION BOX ALONGSIDE DEVICE FIELD VERIFY 17111 MONITOR MODULE FIELD VERIFY ADDRESSABLE RELAY FIELD VERIFY R AbfivAn General No/ N.F17A, 72-2002 Edition 1 -sec 5,63,/ .,,heal -sensing fire detectors shall be located on the ceiling not less than lOOmm (4 in, from or � the eidcwall on Me sidewalk between /OOmm and 300„m (oin, and /Zin) from the ceiling, See figure F.563J A' 2 sec. 5,7,3,2./ .,,smoke detectors shall be located on the ceiling not ■ less than lOOmm C4 in.) from a sidewal/ to /he near edge or, if on a sidewall, bdween 100mm and 300mm (oin, and 12in) down from the ceiling to the lop of the detector. See figure F,5.732,1 A1,5.7,4,/ Detectors should not' be located in a direct airflow or • closer than lm C3 ft) from an air supply diffuser or re/urn air opening, Supply or return sources larger than those commonly found in residential and small commercial establishments can require greater clearance to smoke detectors Similarly, smoke detectors should be located farther away from high velocity air supplies. 4\4 -sec. 5.12.4 The operable part of each maid fire darn box shall be • , not less than Lin (34 ID and not more than 137,, (4 %Z f1,) above floor level. See figure F5,/2,4 A5 -Sec 7.5.4 Wall mounted appliances shall be mounted such that the / \ entire lens is not less than 21-7(80 in.) and not greater than 2.4,, (96 in.) above the finished floor, See figure F.7.5,4 6 -Sec, 4.4.1.4,1 Dedicated branch circuit. A dedicated brarrh circuit of / . \ one of the following shah supply primary power: (1)Commercial light and power, (2) An engine -driven generator or equivalent in accordance with 4.4,/9.2, where a person specifically /rained in its operations is on duty d all tires, (3) An engine -driven generator or equivalent' arranged for cogereralion with comrierciallighl and power in accordance will? 4,4,1.92, where a person specifically trained in its operation is on duty at all luxe, 100 mm (4 in.) Ceiling t00mm (4 in-) minimum 300 (12 maximum mm in.) Ia r//////1/7/./z/ Acceptable hen: Never here Top of detector acceptable here Note: Measurements shown are to/ the closest edge of the detector. 2 / / / / / / / / 1. ''6`_,'1 ,,/,32,1 Sidewall Sidewall / / / / / / 2.4 m (96 in.) maximum 2m (80 in.) minimum Lens Finished floor //////////I MAP OF LOCATION jec> d>�t: PARK PLACE BY THE WOODS "��t:ll�, _74,4 Ptbj Preparg ' NELS :lStarld t? oura 5 `e 12 te: 1 .. . ...................................... h4 t p#ats:Nl2r sing, ..:.. iiiWfiatls'<1g , ID 1 ..::.:1'013£4:1.1 FX-350-60DR Fire Alarm Cortr�i E ar eE :... Ms NAC ........€ii.a a ;Partsi'darrerit= 5.0 Amps ELECTRICAL ROOM 24 V 34.3 w4rtreitt k.7f2t+d 11 • Stan�bss: �ilartirl.;:.>:::. 1 0 220 0 380 Addrshl SLC Devices 14 0 005 0 056 FX -350 CTRL Panel RAM-300LCDR PG M.;11041 GMAY 42 P 110" FG fv1-I/0 44 Other Other Notification .App/ Circuit Not cation Appl Circuit Notification Appl Circuit Notification Appl Circuit *1 # of NAC's Used 0 016 0,000 0000 0 000 0000 0 000 0 000 0 000 0 000 0 000 0.000 0 000 0 000 0 000 0 040 0.000 0.000 0 000 0.000 0 000 0.000 0.000 0 000 0000 0 394 0.168 0.000 0.000 0000 0 000 We A4 Tvp t Etn3s":P :l lLt Ft S f:? is Vohs p 414 Solid 414 Solid 414 Solid 414 Solid 150 15 ': M milli0ifiattary Am pH&O.::Rectuked 7.64 is 66 Command Shortcuts Configure Circuits 4'3% ' 06% 0.00a Print Page IIIb Project Information I Project Name: PARK PLACE BY THE WOODS Prepared By: NELS Project ID: 87474 Date: 1/5/2009 OVA* Natiiflltcatian / U ':' Panel 113 f)0 3 ] 60DR. :`>'; "lam use, Notification App/ Circuit 611 t# i t naw TOA itdf 'if';?""':AIsrtmt 2 ZNS-MCW-FR 30cd 0.214 3 ZRS-MCW-FR 15cd 0;180 Unused 000::: 0.000” Unused 0.00071. y00©- ,134<. Totals 0 000 0.394 ;' €ft'Et��<"Ed�iificatli�ti.H,ppl rot 4r Notification Appl circuit • I" ps .e4c13 : rret+it3raw Tote} 1 MB -G10 & RSSP 7..109 .. 0.000 Unused 000. 0 Unused 0 Unused Totals 0.000 0.188 et t€66'A Panel 1fl: EX0020,00R }:l4: Notification Appl Circuit 'r A,Ierff ll `370 urrent Dra'N.:: .sLh;; andk y :. Unused Unused Unused 6?. 0.00E 0 Unused 0.0009:::. 0 0000.:s €0n3e:'r �tatificatiori'A.ppl;' ` Y<i Unused Totals 0000 0-000 Panel iiia PX=380 6 i€ '> .'(/o iJ54 Notification Appl Circuit ., ..:4UfiftliN Alarsti:< '" 0,000 Unused 0 .... 0,440 : ` Unused OCs Unused 0000 :30 Totals 0 000 0.000 ACCEPTED [j Witho,1t Comments i' As rcai.~y' in Red O P:- T;:ttacrled Letter n,: The Tukwila Eire - ' 'fr: vt;th current City .ct and .. .., errors a Nrtn.7;atl0^,s of adopted r:: sitiiiic for the ...is 1'„siJVn?. � - plans j1. ,. - t . 14tion. . -1asA�,_ n whie: '-.,3ndards anti tit adequacy of desipr t 0 L.1'Y with the designer. Additions, deal ,`. or u.t. 0;,s to these drawings after this date will void _n's a: ptar)ce and will require a resubmittal of re‘/;c,ed drwinc.,s for subsequent approval. Final acceptant: 's subject to field test and inspection by The Tukwila Fire Prevention Bureau. j- 7-01 Date: TUKWI1.A FIRE DEPARTM n Please call: 5754407 and give this job No. o`/-F-oo 1 t and exact address for shut• down or rast1ration approval. -(- P-6Ih1�1- 4ddi.,)c lel• { req t1 44 (c.-414 /h hi -001-1 • 1... yr 5t4 ll `‘F'iK Aelcort.. Cbhir+v ( ' FAk� roo�. ohoOr _.1h5��11 1ocko,' �evice oti FA deoViccir C\ cv: - b✓ ql‹.0( 1- -h5 it -Pt.t. i 16,,0' etY Su74 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and terra nation of the testing. IMPORTANT NOTICE Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. PAIS _ 2001 Tukwila Fir e -J 0 a z 0 rn wcc 0 z w C) Z w 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS ci CO W F— Z LU 2 0 co 0 TUKWILA WA, 98188 CC w CC LI— RISER/BOM - FIRE ALARM PLAN APPROVED BY: ER DRAWN BY: RG DATE: 1-5-09 JOB# 87474 DWG. NO.: FA -01 J .• Operable M pert 11 1.1 (3Y min 1.37 (4A maximum m 8.) mum m ft.) fr,2,4 Finished floor —Sidewall //7/////////// Sidewall / / / / / / 2.4 m (96 in.) maximum 2m (80 in.) minimum Lens Finished floor //////////I MAP OF LOCATION jec> d>�t: PARK PLACE BY THE WOODS "��t:ll�, _74,4 Ptbj Preparg ' NELS :lStarld t? oura 5 `e 12 te: 1 .. . ...................................... h4 t p#ats:Nl2r sing, ..:.. iiiWfiatls'<1g , ID 1 ..::.:1'013£4:1.1 FX-350-60DR Fire Alarm Cortr�i E ar eE :... Ms NAC ........€ii.a a ;Partsi'darrerit= 5.0 Amps ELECTRICAL ROOM 24 V 34.3 w4rtreitt k.7f2t+d 11 • Stan�bss: �ilartirl.;:.>:::. 1 0 220 0 380 Addrshl SLC Devices 14 0 005 0 056 FX -350 CTRL Panel RAM-300LCDR PG M.;11041 GMAY 42 P 110" FG fv1-I/0 44 Other Other Notification .App/ Circuit Not cation Appl Circuit Notification Appl Circuit Notification Appl Circuit *1 # of NAC's Used 0 016 0,000 0000 0 000 0000 0 000 0 000 0 000 0 000 0 000 0.000 0 000 0 000 0 000 0 040 0.000 0.000 0 000 0.000 0 000 0.000 0.000 0 000 0000 0 394 0.168 0.000 0.000 0000 0 000 We A4 Tvp t Etn3s":P :l lLt Ft S f:? is Vohs p 414 Solid 414 Solid 414 Solid 414 Solid 150 15 ': M milli0ifiattary Am pH&O.::Rectuked 7.64 is 66 Command Shortcuts Configure Circuits 4'3% ' 06% 0.00a Print Page IIIb Project Information I Project Name: PARK PLACE BY THE WOODS Prepared By: NELS Project ID: 87474 Date: 1/5/2009 OVA* Natiiflltcatian / U ':' Panel 113 f)0 3 ] 60DR. :`>'; "lam use, Notification App/ Circuit 611 t# i t naw TOA itdf 'if';?""':AIsrtmt 2 ZNS-MCW-FR 30cd 0.214 3 ZRS-MCW-FR 15cd 0;180 Unused 000::: 0.000” Unused 0.00071. y00©- ,134<. Totals 0 000 0.394 ;' €ft'Et��<"Ed�iificatli�ti.H,ppl rot 4r Notification Appl circuit • I" ps .e4c13 : rret+it3raw Tote} 1 MB -G10 & RSSP 7..109 .. 0.000 Unused 000. 0 Unused 0 Unused Totals 0.000 0.188 et t€66'A Panel 1fl: EX0020,00R }:l4: Notification Appl Circuit 'r A,Ierff ll `370 urrent Dra'N.:: .sLh;; andk y :. Unused Unused Unused 6?. 0.00E 0 Unused 0.0009:::. 0 0000.:s €0n3e:'r �tatificatiori'A.ppl;' ` Y<i Unused Totals 0000 0-000 Panel iiia PX=380 6 i€ '> .'(/o iJ54 Notification Appl Circuit ., ..:4UfiftliN Alarsti:< '" 0,000 Unused 0 .... 0,440 : ` Unused OCs Unused 0000 :30 Totals 0 000 0.000 ACCEPTED [j Witho,1t Comments i' As rcai.~y' in Red O P:- T;:ttacrled Letter n,: The Tukwila Eire - ' 'fr: vt;th current City .ct and .. .., errors a Nrtn.7;atl0^,s of adopted r:: sitiiiic for the ...is 1'„siJVn?. � - plans j1. ,. - t . 14tion. . -1asA�,_ n whie: '-.,3ndards anti tit adequacy of desipr t 0 L.1'Y with the designer. Additions, deal ,`. or u.t. 0;,s to these drawings after this date will void _n's a: ptar)ce and will require a resubmittal of re‘/;c,ed drwinc.,s for subsequent approval. Final acceptant: 's subject to field test and inspection by The Tukwila Fire Prevention Bureau. j- 7-01 Date: TUKWI1.A FIRE DEPARTM n Please call: 5754407 and give this job No. o`/-F-oo 1 t and exact address for shut• down or rast1ration approval. -(- P-6Ih1�1- 4ddi.,)c lel• { req t1 44 (c.-414 /h hi -001-1 • 1... yr 5t4 ll `‘F'iK Aelcort.. Cbhir+v ( ' FAk� roo�. ohoOr _.1h5��11 1ocko,' �evice oti FA deoViccir C\ cv: - b✓ ql‹.0( 1- -h5 it -Pt.t. i 16,,0' etY Su74 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and terra nation of the testing. IMPORTANT NOTICE Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. PAIS _ 2001 Tukwila Fir e -J 0 a z 0 rn wcc 0 z w C) Z w 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS ci CO W F— Z LU 2 0 co 0 TUKWILA WA, 98188 CC w CC LI— RISER/BOM - FIRE ALARM PLAN APPROVED BY: ER DRAWN BY: RG DATE: 1-5-09 JOB# 87474 DWG. NO.: FA -01 J 1 2 8 10 F G H FITNESS CENTER BUSINESS CENTER J TO FACP WP EOL •UI1! 75cd r BOILER RM. TO NAC CKT.# 2 B RECREATION AREA STORAGE CABANNA NOTIFICATION DEVICE PLAN 1 /8" =1 '-0" NO ATTIC FROM BELOW A ATTIC O 194° 1:013 NO ATTIC "--o FROM BELOW p—A 194" 1:014 ATTIC CABANNA ATTIC PLAN 1/8"=1'-0" 1:009 e BUSINESS CENTER UP TO ATTIC REST ROOM \vim----A----�-J BEAM 1:008 FITNESS CENTER 1:010 REST ROOM 1:011 1:012 BOILER RM. 1:005 UP TO ATTIC p—A RECREATION AREA 1:002 CABANNA INIATING DEVICE PLAN 1/8"=1'-0" 1:007 STORAGE K GENERAL NOTES: 1. HEAT DETECTORS IN THE ATTIC SPACE SHALL BE 194° FIXED TEMPERATURE. 2. DEDICATED FIRE ALARM SYSTEM CIRCUIT SHALL BE EQUIPPED WITH LOCKOUT DEVICES. 3. CONTROL PANEL RESET CODE SHALL BE 1-2-3-4-5 L M N z 0 rrw ISSUED FOR APPROVAL 0 w 0 z • 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 TUKWILA WA, 98188 1ST & ATTIC FLOOR - FIRE ALARM PLAN APPROVED BY: ER DRAWN BY: RG DATE: 1-5-09 JOB# 87474 DWG. NO. : FA -02 1 A B C 0 E F G 2 3 5 6 7 8 9 10 194° 1:013 ATTIC 194° 1:014 H J 1:012 1ST FLOOR #16/2 —in 1:011 1:010 1:009 1:008 #16/2 1:007 1:006 1:005 1:004 1:003 O 1:002 1:001 BELL 75cd EOL CO 040mA 138mA 15cd 15cd15cd 30cd 30cd EOL —® ® Ng Ng 060mA 060mA 060mA 184mA 184mA #16/2 #14/2 REMOTE ANNUNCIATOR TO CENTRAL STATION MODEL RAN•30LC0 #18/4 PHONE LINE #1 PHONE LINE #2 120 VAC (DEDICATED CKT.) FACP Lr,9 E00000 -U MERCOM FX -350 -60 -DR DUAL UNE DIALER s --T SLC NAC -1 #16/2 NAC -2 NAC -3 NAC -4 BATTERY BATTERY 12V-12AH 12V-12AR # 14/2 RISER DIAGRAM SPARE SPARE K CIRCUIT DISCRIPTIONS: CKT.#1 - GENERAL NOTIFICATION CKT.#2 - OUTDOOR BELL AND STROBE L M N 2 0 w ISSUED FOR APPROVAL 0 z w 0 w 0 C) Z bJ Z 0 LL ELECT. FIREOI*099KW 206-575-0311 107 WASHINGTON BLVD. ALGONA WA, 98001 PARK PLACE BY THE WOODS TUKWILA WA, 98188 BUILDING RISER DIAGRAM APPROVED BY: ER DRAWN BY: RG DATE: 1-5-09 JOB# 87474 DWG. NO.: FA -03 _}