HomeMy WebLinkAboutPP - 6450 SOUTHCENTER BLVD #102 - COWLITZ TRIBAL HEALTH - PERMITS AND PLANS6450 SOUTHCENTER BLVD #102 ASSOCIATED PERMITS D18-0376 19-S-046 96-S-122 96-S-016 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Cowlitz Tribal Health 6450 Southcenter BI Permit No.: 19-S-046 Date: March 12, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 000320-0011 Site Address: 6450 Southcenter Blvd Tukwila, WA 98188 Suite Number: Floor: 1 Tenant Name: Cowlits Tribal Health Property Owner's Name: Andover Management Co. Mailing Address: 900 SW 16th sSt Suite 100 Renton City New Tenant? ®- Yes ❑ - No WA State Zip CONTACT PERSON -if there are questions about the submittal. Name: Vadim Timoshchuk Day Telephone: (253) 840-9900 Company Name: Red Hawk Fire Protection, LLC Mailing Address: 901 Valley Ave. NW Suite D Puyallup WA 98371 City State Zip E-mail Address: VadimT@RedHawkFP.com Fax Number: 3322-0107-C Contractor's City of Tukwila BUS -0997549 NICET III number: Business License number: Total number of new/relocated devices or sprinkler heads: 4 Valuation of Project (contractor's bid price): $ 3,000 Scope of Work (please provide detailed information): RHFP is adding and relocating sprinkler heads to accommodate new walls and ceilings. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID BUILDING OWNER OR AUTHORIZED AGENT: PA - 1 2019 Signature: TUKWILA 1KWILA FIRE Date: Print Name: Vadim Timoshchuk y� Day Telephone: (253) 840-9900 Plan Permit App.doc 8/22/14 TFD FP Form 8 Z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit t 8 - 03) ' PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project —+2 1 , L A t‘ixt Type of Inspection: ,As/ri Address: 9 Suite #: �� BUcP Contact Person: Special Instructions: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: Na ine.M..��---- tis f 4-4.) IZ-R-ceAwi"¢.� -- 5P � Fit-, At 1 — "A -ss 6-1- 0 6i-64 r d . << 4N t L4MM"---) Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: A _____ ? 61 Date: On 21/9 Hrs.: t.. C) $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 z i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Projeew ( CEZ— 1)^djAit ffType of Inspection: a 4%1(/' Address: /L Suite #: lP C �� Contact Person: Special Instructions: ,/01;--- Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Qi r Sp-( ivtlL-e.vs Gte_ Needs Shift Inspection: Sprinklers: (..( Fire Alarm: i Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ��- Date: 4/4A 9 IHrs.: ( $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 J FIRE SPRINKLER PLAN 0 2 4 8 16 SCALE 1 /8"=1'-0" l Without Comments O As Noted in Red Per The Attecrle3d getter t Ese plans have been reviewed t\ Tukwila Fire ..,ention Bureau for co?forrnance current City rdards. Accent -n e k subject tc. e- ors and -. sslons which rj.) rii`-1 T 0r ze tfrO'atIni,S =%f adopted : darns and cr _ -c Thc2 rsborsit,irscy for the ;;luacy of desm-- JeSiver. itior r diet} :s 'Y,sio ,5 to i"s'', ese Drawings after ` .1.5 data will 1,z3- 6 ... _ : _ o n and ,itl redulre a Sab tilt? n v/ i''3` f su seduer.t approval. Final acceQta. �su ;yam: _ field test and inspection by Tne Tukwila Fire Pi eaert,c ; Bur eau. Date: 3-/ a -"I q By: s I ��ia� SLA IrIRE 1;/'Er'Ti\ i Plea:�a.:53i�2C6-575-4407 1r��c.nd gtve. its Mie Perymit No. 1g .- -O`t(0 and exact address for shut- down or restoration approv°al. EXISTING BRANCH LINE OR CROSS MAIN; IGS MECH. TEE AB2 BRACKET / FLEX. DROP CEILING -1 i-- SPRINKLER HEAD IGS MECH. TEE TO FLEX. EXISTING—\ OUTLET r—M THREADED x IGS ADAPTER EXISTING -1 BRANCH LINE OR CROSS MAIN AB2 BRACKET rnrr ,r r—AH2-CC / FLEX. DROP CEILING--' --SPRINKLER HEAD IGS MECH. TEE TO FLEX. PRE -DRILL HOLE --- - LID WOOD JOIST 3/8" ALL— THREAD ROD RING HANGER SAMMY SCREW PIPE (2" MAX.) HANGER NO. 14W SAMMY SCREW Sprinkler Legend Symbol 0 Manufacturer Reliable Type Response Pendent Standard SIN R1015 K -Factor 5.6 Size Temperature 155°F Finish ' Escutcheon Chrome Quantity Recessed 4 Total = 4 SCOPE OF WORK THIS PROJECT IS ATENANT IMPROVEMENT. RED HAWK FIRE PROTECTION IS ADDING AND RELOCATING SPRINKLER TO ACCOM MODATE NEW WALLS AND CEILINGS. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES ALL UNDERGROUND WORK INCLUDING BUT NOT LIMITED TO: BACKFILL, SELECT FILL, BREAKING PATCHING, SAW CUTTING, LAWN REPAIR, LANDSCAPING, TREE REMOVAL, STERILIZATION, DEVELOPMENT FEES AND CITY CONNECTION. RELOCATING EXISTING PIPING FOR OTHER TRADES. GENERAL NOTES 1. SPRINKLER SYSTEM DESIGN PER NFPA#13. 2. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED. 3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH NFPA#13. 4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGH OUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. 5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANYAPPURTENANCES THEREOF. 6. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. 7. 1" PIPING TO BE SCHED 40 WITH THREADED OR INNOVATIVE GROOVE SYSTEM (IGS) FITTINGS. 8. ALL PENDENT HEADS TO BE LOCATED IN CENTER LINE OF CEILING TILES. TENANT IMPROVEMENT THIS PROJECT IS ATENANT IMPROVEMENT. THIS FACILITY HAS ALREADY BEEN PROTECTED BYA FIRE SPRINKLER SYSTEM. RED HAWK FP IS ADDING AND/OR RiZOi ATING SPRINKLER -HEADS TOACCOPv1MODA E THE NEW i ENANT JVALL, CEILING, LIGHTING AND HVAC LAYOUT. ALL WORK WILL BE DONE WITHOUT AFFECTING THE CAPABILITY OF THE EXISTING SYSTEM. RED HAWK FIRE PROTECTION, LLC 801 VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 Fax (800) 591-4382 WA CL# REDHAHF901 QP N ICET Stamp WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Scott Seibert 3322-0107-C Level 3 Red Hawk Fire Protection, LLC REDHAWHF901 QP SIgnatura Approvals Required CITY OF TUKWILA OWNER /ARCHITECT Revisions Contract With: SUPERIOR BUILDERS 6313 20TH ST E FIFE, WA 98424 Contact BRANDON ELMER Phone: (253) 878-2779 Fax: _ SYMBOL LEGEND OR •A 0 MT - DENOTES A SPRINKLER HEAD TO BE RELOCATED. - DENOTES A SPRINKLER HEAD TO BE ADDED. - DENOTES AN EXISTING PENDENT SPRINKLER OR OUTLET. - DENOTES AN EXISTING UPRIGHT SPRINKLER OR OUTLET. - MECHANICAL TEE - REPRESENTS EXISTING SPRINKLER PIPE. - REPRESENTS NEW SPRINKLER PIPE. - NEW WALL. VICINITY MAP Macad :m Wmter G rden tIT Fort Ih•nt Park Start-1re Sports Watefwo,k -Gerrie,* 0019 , 1 rn.r.'r,YRS ulactu•ers Mineral Contract Name: COWLITS TRIBAL HEALTH 6450 SOUTHCENTER BLVD TUKWILA, WA 98188 Drawing Title FIRE SPRINKLER P AN Key Plan AREA OF WORK (E) SPRINKLER ROOM Date: Job Number: Designer: Building Permit: February 27, 2019 40148 VADIM TIMOSI ICHUK PAID Drawing No. FA?, - 1-2319 TUKWILA FIRE Frv.v1'->z'_tA r1 FB 2319 TUKWILA FIRE Oc4-Bruning 82013 Form 12419 SOUTH CEnITE2 BLVD ACCEPTED WITHOUT COMMENTS. 10 AS NOTED IN RED 0 PER THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dedt. Aiditions, deletions or revisions to these drawings after this date will void thi_ , :�;atance and will require a resubmittal of revised drawings. Final acceptance is subject to field - inspection by a representative of this department DATE: 57?/9f- BY: S'/1 CITY OF TUKWILA 575-4407 TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job o. and exact address for shut. down or restoration approval. 4 SCOPE OF WORK= I. RELoGP.TE (i) , 111.5' , 'Z CHZ.. RELESSED PE,/Oe-,U-r TO A MIN /MUM Co" OFF WALL . rgTfigrim MAY 6 1996 SMITH FIRE SYSTEMS, INC. 4519 South Orchard Tacoma, Washington 98466 CONTR. REG. NO SMITHFSI360T Bus: •(206) 473-6967 Fax: (206) 475-1205 PROJECT AMER' CAM Sp,—ES LEADS Co 4 50 S O U TN C EN TE IZ _ 81_v D, To Kt.J ILA DESIGNER DATE SHEET JOB NO. D.X. HUGHE`c 5-3-9to 1 OF I 5-17_89 Oce-Bruning 82013 Form 12419 ACCEPTED c'WITHOUT COMMENTS. ❑ AS NJTED IN Rt=) ❑ PER THE ATTAC ,ED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. A.i .iiticns, deL tions or revisions to the 'r 'wings after this date will void thi : .A..1nOe and will require a resubmittal of revised drawings. Final acceptance is subject to field - inspection by a representative of this department CITY OF TUKWILA 575-4407 REI✓IoVE TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job / /�o No. 96,— "Si' 0 and exact address for shut- down or restoration approval. fp - Ex (STING ARMovER REPLACE WITH 1(0-(0) RI I P P L E. CUT INTO EXISTING a" RRANCHLINE WITH 2"1( IIS MEd -i. T E E SPRINKLERS: ES RELIABLE "G' R• RELIABLE V AS RELIABLE"G1 SSP- REC SSP -REC SSP- REC 2 BILE r I I I I 2 EXTEND EXISTING ARMOVER, Q Y AND ICI -O) SCOPE OF WORK SMITH FIRE SYSTEMS WILL RELOCATE (2) SPRINKLERS AND ADD (1) SPRINKLER TO ACCOMMODATE FOR THE TENANT IMPROVEMENTS. DESIGN CRITERIA PER NFPA #13: OFFICE LIGHT HAZARD CLARIFICATION ALL AREAS PROTECTED BY WET PIPE SPRINKLER EQUIPMENT MUST BE PROTECTED BY OTHERS TO A MINIMUM OF 40° F EXCLUSIONS * PAINTING AND/OR LABELING OF SPRINKLER PIPE AND ECU(PMENT ELECTRICAL WIRING OF ANY KIND STRUCTURAL REVIEW AND ENGINEERING FEES TO DETERMINE IF THE STRUCTURE IS ADEQUATE TO SUPPORT THE SPRINKLER SYSTEM CENTRAL STATION MONITORING EQUIPMENT, SERVICE, AND WIRING NOTES ALL MATERIAL TO BE UL LISTED AND/OR FM APPROVED ALL HANGERS TO BE IN ACCORDANCE WITH NFPA #13 ALL ARMOVERS IN EXCESS OF 2' - 0" TO BE SUPPORTED WITH A HANGER * * r- CHR/c HR CHR/CHR CH R/C HR 12" 12" SPRINKLER PLAN SCALE: 14"-4, I6go 3 165° a 1(05° TQTA L Co .14t410, SMITH FIRE SYSTEMS, INC. 1106 54th Ave. E. Tacoma, WA 98424 CONTR. REG. NO SMITHFS1360T Ph: (206) 926-1880 Fax: (206) 926-2350 PROJECT ROYAL COACHMAN 6450 SOUTHCENTER BLVD #102 TUKWILA, WAHINGTON DESIGNER DATE SHEET JOB NO. M. BRANDEWIE I - - I OF 5- 1117