Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 4415 S 150TH ST - THORNDYKE ELEMENTARY - PERMITS AND PLANS
4415 S 150TH ST ASSOCIATED PERMITS M19-0092 D19-0075 19-F-146 19-F-164 19-S-146 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 0042000280 Site Address: 4415 S 150th Street Suite Number: Floor: Tenant Name: Thorndyke Elementary Property Owner's Name: Tukwila School District Mailing Address: 4415 S 150th Street Tukwila, WA. 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Nikki Rodewald Day Telephone: 206-851-1900 New Tenant? ❑ - Yes ❑ - No Company Name: Cosco Fire Protection Mailing Address: 4308 S 131st Place Tukwila, WA. 98168 City State Zip E-mail Address: nrodewald@coscofire.com Fax Number: Contractor's City of Tukwila NICET III number: 2125-0314-c Business License number: BUS -0995340 Total number of new/relocated devices or sprinlder heads: 8 Valuation of Project (contractor's bid price): $ $13,854. Scope of Work (please provide detailed information): Provide new heat traced 3" schedule 40 pipe to tie the pre -designed fire sprinkler system in new portable unit to existing system. relocate 4 pendents and 2 uprights to conform with tenant improvement. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR IA GTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Nikki Rodewald .',` 1! 2019 TUKWILA FIRE Plan Permit App.doc Date: 7-15-19 Day Telephone: 206-851-1900 8/22/14 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Permit No.: Date: Reviewer: Thorndyke Elementary 4415 S 150th St. 19-S-146 July 26, 2019 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • Weld stamps shall be inspected on the ground, before the pipe is hung. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2019 Edition. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: `j0 //a' Type of inspection: g //C4 r ASuiteddress:#:q(415---5 ) Contact Person: ,v, ci Special Instructions: Phone No.: 647-5 57(-).Z-37,6 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 56n. OLS 50(9 etvj5ce_ v- oRwl Cgt c\4sL \\.*Ak Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: f\ \ Occupancy Type: I Inspector: ,dT \\\ iii ZL( Date: ,- ` 1 rd " Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit cre[f'' PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ,____.- 1Vk O'Ac tjJ e Type of Inspection: /kA,1 4 ii4)9w Address:Contact Suite #:�� S�c�7GL Person: ( e Special Instructions: 1 Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: r'., Sprinklers: ��`.:wi( t i%�.4� : i ) k) \---?ailM � 1 : 4 7: C1),-,4 Monitor: Pre -Fire: Permits: , I /r(J 1 kFrp.Af-Cprxaieb7432:&0-rFi .iTf - TAP- s,4 i 00-) —70 --14g7C I --t v1^ -c1 A✓1, CdLWlt 155j 6 _'e( 601410mi . Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: , I Occupancy Type: Inspector: er 1 /i ('-'f Date: /Z/7 //9 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 y INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit (et -5- 1'd4 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:____d �% Y Type of Inspection: HYPPU / C d Le Address: rp, Contact Person: p Suite #: `T / S S /S o7. Special I structions: 1-11 (o4 L 1711 L Ili- //-) Phone No.: '"ZS' ,—/rers'— k Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:.( , (\ Date: 101 ( I il Hrs.: 1 I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:,77,0 ru r / Type of Inspection:F. Address:Contact Suite #: cie(/s-- S. \S-.6 4-1-- Person: Special Instructions: Permits: Phone No.: Approved per applicable codes. COMMENTS: Corrections required prior to approval. A-F7on- 4u rS lAi-sp 49 ccca 7-9-' fvT /+1/471-. ��vwlx- t N 0-610.<-0-14AS Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: (,//1 15G- t7fS3 Date: fi 12V ct Hrs.: / ( 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Is %`" Type of Inspection: 5Pe -'f6r c2 Hood & Duct: �� Monitor: bi`((3-S IC°t Contact Person: rASudidtere#ss:: ��2.7 Special Instructions: k Phone No.: 1,Cb — S3 — cZ3 (D Approved per applicable codes. COMMS TS: Corrections required prior to approval. Needs Shift Inspection: 49 Sprinklers: 103 Fire Alarm: Hood & Duct: �� Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: c `s'�J( Date: 'fI , 1 \A Hrs.: I- $100.00 REINSPECTION FEE REQUIRED. You will t<eceive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.C.D. Form F.P. 113 INSPECTION NUMBER - INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: A-0 Sprinklers: Type o Inspection: Address:Contact Suite #: W/,- ,S./3 Person: Special Instructions: Occupancy Type: Phone No.: ?c, Approved per applicable codes. / fh€-5- COMMENTS: Corrections required prior to approval. #ril'N,t2436D -kg Old Cover") Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: -71c-z___ lr&S---3 Date: e/6/ /1 Hrs.: % , 0 I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 City of Tukwila Fire Department FIRE WATCH REQUIRED Due to the inoperative fire protection system(s) in your facility, you are required to provide a fire watch per City of Tukwila Ordinance #2437, section 16.40.120-D and Ordinance #2436, section 16.42.100-C (see reverse side). The fire watch shall be maintained until the system(s) are operational as determined by the Tukwila Fire Marshal's Office. FAX paperwork to 206-575-4439 to verify the completion of repair work and/or the restoration of system monitoring, in order to end the fire watch. The fire watch is required 24 hours a day. Designated employees may serve as the fire watch during business hours, while performing their regular job. Fire watch personnel must be aware of, and accept the duties of the fire watch. After hours fire watch personnel must be on location and must patrol the building following the close of business. Every two hours they must call 206-971-8737 and leave a message stating the following: 1. Your name. 2. Street address of firewatch location. 3. Time of day. 4. If everything cis OKAtate all clear. If you discover an emergency during your patrol , call 9-1-1 immediately to report it. Date: /`)l -<S !tInspectors: Pe Reason For Fire watch: 2 yQC C. a t Start time: 10 't SI CD, 5-9) t�0 -tcg°la - CT**ncident #: I UN oo'L . AAv to th,, OA)/16 C- lib /4 /4-U7-74lN A f2*SET Business Name: `T Hoz i:N(I<ClQ r# c (Tv Kw1= PDQc-K- ' (-r-�S) Business Address: / Business Phone: .2 3 G C 3> 9 Person in Charge: L -1=-1-1-Y Signature: W - Fire Marshal's Office Y - Owner/Manager Rev. 7/29/14 T.F.D. Form F.P. 41 Tukwila Fire Marshal's Office • Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshal@atukwilawa.gov April 17, 2017 City of Tukwila Allan Ekberg, Mayor Fire Department Ms. Judith K. Berry, PhD Deputy Superintendent Tukwila School District 4640 S. 144 Street Tukwila, WA 98168 F� L s Jay C. Wittwer, Fire Chief RE: City of Tukwila Fire and Park Impact Fee exemption for Tukwila School District Dear Ms. Berry: Upon further review of your letter dated February 21, 2017 and consulting with the affected City staff members for Park and Fire Impact fees, the following has been determined. In regard to Park Impact Fees for the upcoming District projects, none will be assessed with the exception of the transportation office building which is assessed $2,105.06 in Park Impact Fees. In regard to Fire Impact Fees, they will apply to all of the proposed projects by the Tukwila School District. The procedure is outlined within Exhibit "A" table 2 of Tukwila City Ordinance number 2365; Educational Occupancies are the second category within this table. Educational Occupancies are specifically included within the office category based on fire department response data. The response data was reviewed from 2014 to 2016, and this analysis confirmed that educational occupancies are correctly placed in the "office" category due to similar response needs. In fact, the most recent data revealed an increased impact to the fire department by educational occupancies. In 2016 under the office category there were 1,352 calls for service, of which 114 were to educational occupancies or 11.8%; of those 11.8%, Tukwila Schools accounted for 33% of those calls for service which is a 6% reduction in calls for service to Tukwila Schools when compared to the 2014 to 2016 calls for service average. (Reduction was most likely from fire alarm panel repaiirs at Foster High School and because a juvenile fire setter moved out of the area.) Tukwila Fire Marshal's Office • 6300 Southcenter Blvd., Suite #209 • Tukwila, Washington 98188 • Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshaltukwilawa.gov City of Tukwila Page 2 In reference to your comments based on Revised Code of Washington 82.020.050, all monies collected for impact fees will be used to support the system improvements caused by the district development and expansion. Fire Department staff has been in discussion with the District's design team and project manager to determine the exact square footage of the expansion. This process has been delayed by the value engineering process phase. When this process is completed and fire staff is made aware of the exact additional square footage for each project, an impact fee calculation can be made. You should be aware that during the calculation process Tukwila Municipal Code 16.26.120 (b) (1) will be applied to more accurately reflect the actual additional square footage added to Foster High School and Showalter Middle School. Your reference to Tukwila Municipal Code 16.26.120 (b) (2), would only apply if no new additional classrooms or common space is constructed, which is not the proposed addition fire staff has reviewed to date. The impact fees for both Foster High School and Showalter Middle School will be calculated such that credit will be given for the square footage of the portable buildings that will be removed from both sites at the end of the projects, estimated by fire staff at 11,000 square feet for Foster High School and 4,000 square feet for Showalter Middle School. Fire staff will continue to work with the District design team to determine the correct impact fee calculation for these two projects. In regard to the Birth to Kindergarten Center, it will be assessed fire impact fees. Fire will experience an increased number of calls for service as a result of this facility. This facility location will bring additional calls for service within the fire station 54 response zone. This is the City's busiest fire response zone and any additional fire calls for service require mitigation strategies to minimize the impact to existing fire service customers. I have included an attachment for you on fire department calls for service to Tukwila School District facilities. Yours truly, Battalion Chief Don Tomaso Fire Marshal cc: David Cline, City Administrator Jay Wittwer, Fire Chief Rick Still, Director Parks and Recreation Jack Pace, Director Department of Community Development Tukwila Fire Marshal's Office • 6300 Southcenter Blvd., Suite #209 • Tukwila, Washington 98188 • Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshalgtukwilawa.gov 10 Tukwila School District Fire Response Data 2014 - 2016 Administration Building FALSE 2014 ADDRESS = 4640 S 144 ST Foster High School EMS 2016 1111 MIMI= FALSE GOOD INT .. FIRE PUB ASS1 FALSE GOOD INT EMS OTHER RUPT/EXj FALSE EMS FIRE 2014 2015 I 2016 ADDRESS = 4242 S 144 ST Showlater Middle School 3 ADDRESS = 4628 S 144 ST Page 1 of 2 Tukwila School District Fire Response Data 2014 - 2016 Tukwila Elementry School 2014 1 2015 ADDRESS = 5939 S 149 ST GOOD INT EMS Thorndyke Elementry School 3 2016 GOOD INT EMS ADDRESS = 4415 S 150 ST Cascade View Elementry FALSE 2015 ADDRESS = 13601 32 AVE S Page 2 of 2 1• .••••••. •••••••• ••••••• COSCO Fire Protection FIRE PROTECTION MATERIAL SUBMITTAL THORNDYKE ELEMENTARY 4415 SOUTH 150TH ST TU KW I LA, WA. 98188 98168 Fire Protection Contractor Cosco Fire Protection 4308 South 131st PI. Tukwila, Washington 98168 (206) 438-3360 Fax: (206) 438-3356 JOB # 25SS8647 .••••••. ••••••.. 'e•••••• .••••••, COSCO Fire Protection TABLE OF CONTENTS SECTIONS PAGES 1. PIPE AND FITTINGS a. Schedule 40 4 b. Threaded Fittings 5 -10 c. VICFLEX AH2 Hose 11- 34 d. Metraflex fireloop 35-40 2. SPRINKLER HEADS a. Reliable F1FR sprinklers 3. HANGERS 3 -43 a. Sammys For Wood 45-49 b. Sammy Sidewinder 50 c. Rin an ers 51-53 d. II rea Ro 54 0 0 0 .••••••. •••••••• . •••••• '••••'" COSCO Fire Protection SECTION 1. PIPE AND FITTINGS FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C -UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: • ASTM A135, Type E, Grade A (Schedule 10) • ASTM A795, Type E, Grade A (Schedule 40) • NFPA 13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion -resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot -dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is'acceptable as a supplementary identification method. SCHEDULE 10 SPECIFICATIONS NPS NOM OD In. mm NOM ID In. mm NOMINAL WALL in. mm NOMINAL WEIGHT lbs./ft. kg/m UL PIECES CRR Lift 11/4 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1% 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 2' 3 4 2.875 3.500 4.500 5 5.563 6 6.625 8 8.625 73.0 2.635 66.9 .120 3.05 88.9 3.260 82.8 .120 3.05 4.34 6.46 114.3 4.260 108.2 .120 3.05 5.62 8.37 141.3 5.295 134.5 .134 3.40 7.78 11.58 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 3.53 5.26 3.5 2.6 1.6 1.5 30 19 19 13 • Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. • The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SC HEDULE 40 SPECIFICATIONS NOMINAL NOMINAL -, -- NPS NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm in. mm In. mm lbs./ft. kg/m CRR Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 PA 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 11/2 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 • Caiculated using Standard UL CRR formula, UL Fire Protectlon Directory, Category VIZY. The CRR Is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 1.0). PROJECT: ENGINEER: LOCATIONS: ❑ BLACK rk 700 South Dock Street info'wheatland.com Sharon, PA 16146 wheatland.com P 800.257.8182 Follow us on Twitter: F 724.346.7260 :'alWheatlandTube CONTRACTOR: SPECIFICATION REFERENCE: COMMENTS: DATE: SYSTEM TYPE: ❑ HOT -DIP GALVANIZED W f 5-051516 Me fid Tube A DIVISION OFZEKELMAN INDUSTRIES SPF/ANVIL ©UCIIILE MOM VEME&DEJ FEITEI AGO FIG. 3201 90° Elbow 71' A FIGURE Nominal Size 3201 Maximum Working Pressure., - 90° ELBOW Dimension A Approx. Wt. Each In. (mm) P51(kPa) In. (mm) lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 11 500 1.75 0.90 32 3450 44.45 0.41 11/2 500 1.94 1.20 40 3450 49.276 0.54 2 500 2.25 1.85 50 3450 57.15 0.84 ♦ — Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. US LISTED APPROVED For Ustings/Approval Details end Umitations, visit our website at www.envilintl.com or contact en Anvil* Sales Representative. MATERIAL SPECIFICATIONS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four tums. PROJECT INFORMATION APPROVAL STAMP Project: 0 Approved Address: 0 Approved as noted Contractor: 0 Not approved gineer: Submittal Date: Notes 1: Notes 2: Remarks: SPF/DI-1.15 MALLEABLE IRON THREADED FITTINGS ,(0)AJWIL Class 150 (Standard) FIG. 3105R Reducing Tee 2 1 x2x3 3 FIGURE 3105R - REDUCING TEE Nominal Size Address: Dimensions Approx. Wt. Each 1 2 3 A B C In. (mm) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1/4 0.97 0.97 0.98 0.24 8 24.64 24.64 24.89 0.11 3/e 1.04 1.04 1.03 0.27 1/2 1/2 10 26.42 26.42 26.16 0.12 15 15 3/4 1.22 1.22 1.20 0.37 20 30.99 30.99 30.48 0.17 1 1.36 1.36 1.26 0.49 25 34.54 34.54 32.00 0.22 1/2 1.20 1.12 1.22 0.38 14 15 30.48 26.16 28.45 0.17 15 3/4 1.31 1.22 1.31 0.45 20 33.27 28.45 33.27 0.20 1/4 1.05 1.05 1.08 0.36 3/4 8 26.67 26.67 27.43 0.16 20 3/e 1.12 1.12 1.13 0.39 3/4 10 28.45 28.45 28.70 0.18 20 1/2 1.20 1.20 1.22 0.43 15 30.48 30.48 30.99 0.20 1 1.45 1.45 1.37 0.62 25 36.83 36 83 28.45 0.28 1/4 1 1.50 1.18 1.50 0.63 8 25 38.10 29.97 38.10 0.29 1/2 1.26 1.12 1.36 0.48 1 15 32.00 28 45 34.54 0.22 25 1/2 3/4 1.37 1.22 1.45 0.56 15 20 34.80 28.45 34.54 i 0.25 1 1.50 1.36 1.50 0.67 25 38.10 34.54 38.10 0.30 cODs USTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil° Sales Representative. MATERIAL SPECIFICATIONS Dimensions: Fittings: ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME B16.14 Material: ASTM A-197 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads*: NPT per ASME B1.20.1 Pressure Ratings: Fittings: ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME B16.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using an air under water process. Agency Approvals: All malleable iron fittings and unions are UL/ULC Listed and FM Approved. * British Standard threading per BS 21 available upon request. PROJECT INFORMATION Project: APPROVAL STAMP ❑ Approved Address: ❑ Approved as noted Contractor: ❑ Not approved t Engineer: Remarks: J Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 MALLEABLE IRON THREADED FITTINGS Class 150 (Standard) FIG. 3105R Reducing Tee 2 1 x 2 x 3 3 FIGURE 3105R - REDUCING TEE Nominal Size Dimensions Dimensions Approx. Wt. Each 1 2 3 A 8 C In. (mm) In. (mm) In. (mm) In. (mm) Lbs. (kg) 14 1.26 1.20 1.36 0.53 15 32.00 30.48 34.54 0.24 3/4 3/4 1.37 1.31 1.45 0.61 20 20 _ 34.80 33.27 36.83 0.28 1 1.50 1.45 1.50 0.71 11/4 11/4 25 38.10 36.83 38.10 0.32 32 32 % 1.18 1.18 1.27 0.57 10 29.97 29.97 32.26 0.26 1 1h 1.26 1.26 1.36 0.62 25 15 32.00 32.00 34.54 0.28 3/4 1.37 1.37 1.45 0.69 1 20 28.45 28.45 36.83 0.31 25 11/4 1.67 1.67 1.58 0.94 15 32 _ 42.42 42.42 40.13 0.43 11/2 1.80 1.80 1.65 1.07 3/4 40 45.72 45.72 41.91 0.49 20 2 2.02 2.02 1.73 1.45 50 51.31 51.31 43.94 0.66 1 1.58 1.36 1.67 0.82 1/2 25 40.13 34.54 42.42 0.37 15 11/4 1.75 1.53 1.75 0.95 25 32 44.45 38.86 44.45 0.43 3/4 1.45 1.31 1.62 0.75 20 36.83 33.27 41.15 0.34 3/4 1 1.58 1.45 1.67 0.87 20 25 40.13 36.83 42.42 0.39 11/4 1'/4 1.75 1.62 1.75 1.00 32 32 44.45 41.15 44.45 0.45 40 11/4 '/2 1.34 1.26 1.53 0.74 32 15 34.04 32.00 38.86 0.34 3/4 1.45 1.37 1.62 0.82 1 20 36.83 28.45 41.15 0,37 25 1 1.58 1.50 1.67 0.94 25 40.13 38.10 42.42 0.43 11/4 1.75 1.67 1.75 1.08 32 44.45 42.42 44.45 0.49 SPF/MI-1.15 ANVIL FIGURE 3105R - REDUCING TEE Approx. Wt. Each Nominal Size Dimensions 1 2 3 A 8 ( In. (mm) In. (mm) In. (mm) In. (mm) Lbs. (kg) 3/9 1.26 1.26 1.44 0.78 10 32.67 32.00 36.58 0.35 1h 1.34 1.34 1.53 0.84 15 34.04 34.04 38.86 0.38 3/4 1.45 1.45 1.62 0.92 11/4 11/4 20 36.83 36.83 41.15 0.42 32 32 1 1.58 1.58 1.67 1.04 25 40.13 40.13 42.42 0.47 11h 1.88 1.88 1.82 1.34 40 47.75 47.75 46.23 0.61 2 2.10 2.10 1.90 1.65 50 53.34 53.34 48.26 0.75 1/2 11/2 1.94 1.66 1.94 1.24 15 40 49.29 42.16 49.28 0.56 3/4 1.50 1.26 1.69 0.86 3/4 20 38.10 32.00 42.93 0.39 20 11/2 1.94 1.75 1.94 1.29 40 49.23 44.45 49.28 0.59 1 1.65 1.50 1.80 1.08 25 41.91 38.10 45.72 0.49 1 1'/4 1.82 1.67 1.88 1.23 25 32 46.23 42.42 47.75 0.56 11h 1.94 1.80 1.94 1.35 40 49.23 45.72 49.28 0.61 3/4 1.52 1.45 1.75 1.04 20 38.61 36.83 44.45 0.47 1 1.65 1.58 1.80 1.17 1 25 41.9' 40.13 45.72 0.53 40 11/4 114 1.82 1.75 1.88 1.32 32 32 46.28 44.45 47.75 0.60 11/2 1.94 1.88 1.94 1.45 40 4923 47.75 49.28 0.66 2 2.10 2.10 1.90 1.82 50 53.34 53.34 48.26 0,83 h 1.41 1.41 1.66 1.04 15 35 8! 35.81 42.16 0.47 3A 1.52 1.52 1.75 1.14 20 38.6: 38.61 44.45 0.52 11h 1 1.65 1.65 1.80 1.27 40 25 41.9' 41.91 45.72 0.58 11/4 1.82 1.82 1.88 1.43 32 46.2J 46.23 47.75 0.65 2 2.16 2.16 2.02 1.89 50 54.8i 54.86 51.31 0.86 MALLEABLE IRON THREADED FITTINGS ANVIL Class 150 (Standard) FIG. 3105R Reducing Tee 2 1 x 2 x 3 3 FIGURE 3105R - REDUCING TEE Nominal Size Dimensions Approx. Wt. Each 1 2 3 A B ( In. (mm) In. (mm) In. (mm) In. (mm) lbs. (kg) 1/2 2 2.25 1.88 2.25 1.89 15 50 57.15 47.75 57.15 0.86 3,4 2 2.25 1.91 2.25 1.93 20 50 57.15 50.04 57.15 0.88 2' 2% 1 1.81 1.75 1.87 ; 1.39 65 1 25 45.97 44.45 47.50 ' 0 63 25 2 2.25 2.02 2.25 2.00 50 57.15 51.31 57.15 0.91 11/4 1.90 1.75 2.10 1.64 32 48.26 44.45 53.34 014 11/4 1' 2.02 1.88 2.16 1.80 32 40 51.31 47.75 54.86 0.82 2 2.25 2.10 2.25 2.09 50 57.15 53.34 57.15 0.95 1 1.73 1.65 2.02 1.57 25 43.94 41.91 51.31 0.71 2 11/4 1.90 1.82 2.10 1.71 50 1% 32 48.26 46.23 53.34 0.78 40 1% 2.02 1.94 2.16 1.88 40 51.31 49.28 54.86 0.85 2 2.25 2.16 2.25 2.21 50 57.15 54.86 57.15 1,00 1/2 1.49 1.49 1.88 1.53 15 37.85 37.85 47.15 0.69 3/4 1.60 1.60 1.97 1.63 20 40.64 40.64 50.04 0.74 4 4 1 1.73 1.73 2.02 1.78 100 2 25 43.94 43.94 51.31 0.81 50 11/4 1.90 1.90 2.10 1.97 32 48.26 48.26 53.34 0.89 1' 2.02 2.02 2.16 2.12 40 51.31 51.31 54.86 0.96 2% 2.60 2.60 2.39 3.15 65 66.04 66.04 60.11 1.43 SPF/MI-1.15 FIGURE 3105R - REDUCING TEE Nominal Size Dimensions Approx. Wt. Each 1 2 3 A B C In. (mm) In. (mm) In. (mm) In. (mm) lbs. (kg) 3/4 1.74 1.74 2.32 2.67 20 4420 44.20 58.93 1.21 1 1.87 1.87 2.37 2.84 25 47 50 47.50 60.20 1.29 2' 2% 11 2.04 2.04 2.45 3.09 65 65 32 59.82 51.82 62.23 1.40 ' 1' 2.16 2.16 2.51 3.29 40 54.86 54.86 63.75 1.49 2 2.39 2.39 2.60 3.65 50 6071 60.71 66.04 1.66 2 2 232 2.25 2.89 3.88 50 50 6401 57.15 73.41 1.76 34 1.81 1.87 2.61 3.72 20 41.50 47.50 66.29 1.69 1 2.00 2.00 2.66 3.96 25 50 80 50.80 61.56 1.80 3 11/4 2.17 2.17 2.74 4.23 80 3 32 55.12 55.12 69.60 1.92 80 1% 2.29 2.29 2.80 4.45 40 58.17 58.17 71.12 2.02 2 2.52 2.52 2.89 4.90 50 64.01 64.01 73.41 2.22 2% 2..83 2.83 2.99 5.69 65 71.88 71.88 75.95 2.58 2 2.74 2.74 3.41 7.52 50 0.60 69.60 86.61 3.41 4 4 2'% 3.05 3.05 3.51 8.51 100 100 65 77.47 77.47 89.15 3.86 3 3.30 3.30 3.60 9.25 80 83.82 83.82 91.44 4.20 DUVE1LE MOM t' EM& ED FB i'4IM( S ARR(11.4 FIG. 3221R Reducing Coupling FIGURE 3221R - REDUCING COUPLING Nominal Size Maximum Working Pressures Dimension A Approx. Wt. Each In. (mm) PSI (kPo) In. (mm) lbs. (kg) 1 x ih 25 x 15 500 3450 1.69 42.92 0.39 0.18 1 x 3/4 25 x 20 500 3450 1.69 42.92 0.53 0.24 ♦ — Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Project: c®aS LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil' Sales Representative. MATERIAL SPECIFICATIONS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP 0 Approved Address: ❑Approved as noted Contractor: 0 Not approved gineer: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 Remarks: MALLEABLE IRON THREADED FITTINGS (OANVIL Class 150 (Standard) FIG. 3124 Cap FIGURE Nominal Size 3124 - CAP Dimension A Approx. Wt.. Each In. (mm) In. (mm) lbs. (kg) '/SA 0.53 0.03 6 13.46 0.01 '/a. 0.63 0.05 8 16.00 0.02 3/81 0.74 0.07 10 18.80 0.03 1/2 0.87 0.11 15 22.10 0.05 3/4 0.97 0.18 20 24 64 0.08 1 1.16 0.30 25 29.46 0.14 1'/4 1.28 0.44 32 32.51 0.20 1'/2 1.33 0.55 40 33.78 0.25 2 1.45 0.85 50 36.83 0.39 2'/z 1.70 1.49 65 43.18 0.68 3 1.80 2.20 80 45.72 1.00 31/2 1.90 3.02 90 48.26 1.37 4 2.08 3.79 100 52.83 1.72 6 2.55 8.77 150 6477 3.98 ♦ - Supplied in Steel only (Black and Galvanized). CCL US USTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil' Sales Representative. MATERIAL SPECIFICATIONS Dimensions: Fittings: ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME B16.14 Material: ASTM A-197 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads*: NPT per ASME B1.20.1 Pressure Ratings: Fittings: ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME 816.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using an air under water process. Agency Approvals: All malleable iron fittings and unions are UL/ULC Listed and FM Approved. * British Standard threading per BS 21 available upon request. PROJECT INFORMATION Project: APPROVAL STAMP ❑ Approved Address: ❑Approved as noted Contractor: ❑ Not approved Engineer: Remarks: ` Submittal Date: Notes 1: Notes 2: SPF/MI-1.15 Victaulic® Vic-FIexTM Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses jctaulic° 10.85 Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component • Series AH2 Braided Hose: 31, 36, 48, 60, 727790, 914, 1219, 1525, 1830mm. Note: length includes adapter nipple and 5.75"/140 mm straight reducer. • Series AH2-CC Braided Hose: 31, 36, 48, 60, 727790, 914, 1219, 1525, 1830 mm. Note: length includes captured coupling and 5.757140 mm straight reducer. • Sprinkler Reducers: 1/2' and 3/4715 and 20mm sprinkler connections and 5.75, 9, 137140, 230, 330 mm straight lengths and short, long 900elbows. Note: The short 90° elbow is typically used with concealed sprinklers while the long 90®elbow is typically used in the installation of recessed pendent sprinklers. Low Profile long, and short 90° elbows for use with Style AB11 Bracket. • Inlet Connections: • 1"/25 mm Grooved IGS • 1"/25 mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. • 3/4720 mm NPT or BSPT adapter nipples available for VdS. • 11/a°/ 32mm BSPT adapter nipples available for LPCB. • Brackets: • Style AB1 for suspended and hard -lid ceilings, allows installation before most ceiling tiles in place • Style AB2 for suspended and hard -lid ceilings, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls • Style AB4 for hard -lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard -lid ceilings, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard -lid ceilings • Style AB7 Adjustable for suspended and hard -lid ceilings • Style AB8 for hard -lid ceilings with CD 60/27 profile metal studs (regionally available) • Style AB9 for hard -lid ceilings with hat furring channel grid systems • Style AB10 for Armstrong® TechZoneTM ceilings • Style AB11 for lay -in panel suspended t -grid ceilings or drywall suspended t -grid ceilings, allows for low profile installations (use only with 90° low profile elbows) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Submitted By j Date Spec Section Paragraph Approved Date victaulic.com 10.85 5839 Rev AA Updated 12/2016 c 2016 Victaulic Company. All rights reserved. 1 jctaulie victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) Maximum Working Temperature • 225°F/107°C Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) Connections • To adapter nipple (inlet) via • 1725.4 mm Grooved IGS • 1725.4 mm NPT or BSPT male thread • 3/4720 mm BSPT male thread (VdS only) • 11/4732 mm BSPT male thread (LPCB only) • To sprinkler head (outlet) via 1/2" or 3/4715 mm or 20 mm Minimum Bend Radius • 77178 mm (FM Approval) • 2751 mm (cULus Listed) • 3776.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K -Factors • FM (l /15mm reducer) K5.6/8,1 (S.I.), (3/4"/20mm reducer) K14.0/20,2 (S.I.) • cULus (1/715mm reducer) K8.0/11,5 (S.I.), (3/4"/20mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (1/2715mm reducer) K5.6/8,1 (S.I.), (3/4720mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS C 4) DS LISTED VdS LPCB 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 2 ✓ctauIic victaulic.com 3.0 SPECIFICATIONS — MATERIAL • Series AH2 • Flexible Hose: 300 -series Stainless Steel • Collar/Weld Fitting: 300 -series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (1/2 /15 mm or 3/4"/20 mm): Carbon Steel, Zinc -Plated • Low Profile Elbows: Stainless Steel Brackets: Carbon Steel, Zinc -Plated Series AH2-CC • Flexible Hose: 300 -series Stainless Steel • Collar/Weld Fitting: 300 -series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (1/2 /15 mm or 3/4"/20 mm): Carbon Steel, Zinc -Plated • Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:1 • Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and tor a listing of services which are not compatible. • Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 3 ✓ctaulic victaulic.com • 4.0 DIMENSIONS • Product Details - Series AH2 Braided Hose A IAl 1111 IIIIIIIII etIIII IIIII Hose Length Dimensions B Hose Length inches mm A inches mm B inches mm 31/790 25.3/641 31/790 36/915 31.3/794 36/915 48/1219 42.3/1073 48/1220 60/1525 54.3/1378 60/1525 72/1830 66.3/1683 72/1830 Series AH2-CC Braided Hose 0 O i� uimm�nmuu�nduunm, Io it •Cuwunuuum nuwinuwii Hose Length inches mm A inches mm B inches mm 31/790 24.5/622 29.8/757 36/915 29.5/749 34.8/884 48/1219 41.5/1054 46.8/1189 60/1525 53.5/1359 58.8/1494 72/1830 65.5/1664 70.8/1798 • Item Description 1 1 Flexible Hose —� 2 Isolation Ring 4 3 Gasket Captured Coupling 4 Nut 7 5 Adapter Nipple, 6 Braid 7 Collar/Weld Fitting 8 Sleeve Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Captured Coupling 6 Braid 7 Collar/Weld Fitting Sleeve 8 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 4 �OtauIic victaulic.com 4.0 DIMENSIONS (Continued) • Standard Reducer lip111111111111mninummlii [■1 umni�unmiIiii 5.757140 mm straight reducer Optional Reducers 1111 11111/111 IIIIIII 9.0 /229 mm straight reducer c 11111111 iiiiIIH 11111 I 111 III 11111 13.0 /330 mm straight reducer 2.62"/ Short 90° elbow reducer 2 62"/ Long 90° elbow reducer NOTE • The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. •- • 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5 JCtaUIic'' victaulic.com 4.1 DIMENSIONS • VicFlex Brackets Style AB1 • Suspended Ceilings • Hard -Lid Ceilings (FM Only) Item Description 1 24"/610mm or48"/1219mm Square Bar* 2 Patented Center Bracket 3 End Bracket 'Both sizes FM/VdS/LPCB approved, cULus listed Style AB2 • Suspended Ceilings • Hard -Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket 'Both sizes FM/VdS/LPCB approved, cULus listed Style AB3 • Surface Mount Applications • FM Approved • 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 6 • �CtauIiCr victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB4 • Hard -Lid Ceilings with Hat furring channel grid system Item Description 1 24"/610mm or48"/1219mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel 'Both sizes FM/VdS approved, cULus listed Style AB5 • Hard -Lid Ceilings Item Description 1 24"/610mm or48"/1219mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket 'Both sizes FM/VdS approved, cULus listed 0 Style AB7 • Suspended Ceilings • Hard -Lid Ceilings C Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented 1 -Beet• Center Bracket 3 End Bracket 'Both sizes FM/VdS approved. Style AB7 Adjustable • Suspended Ceilings • Hard -Lid Ceilings Item Description 1 700mm or 1400mm Square Bar* 2 Patented 1 -Beet° Center Bracket 3 End Bracket (adjustable) • 'Both sizes FM/VdS approved. 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 7 • ✓ctauIic victaulic.com 4.3 DIMENSIONS VicFlex Brackets Style AB8 • Hard -Lid Ceilings Item Description 1 700mm or 1400mm Square Bar* 2 Patented Vertically Adjustable Center Bracket End Bracket 3 'Both sizes FM/VdS approved. Style AB9 • Hard -Lid ceilings with Hat furring channel grid system Item Description 1 24"/610 mm or 48"/1219 mm Square Bar'° 2 Patented 1 -Beet° Center Bracket 3 End Bracket for Hat Furring Channel 'Both sizes FM/VdS approved. Style AB10 • Suspended ceilings • Armstrong® TechZoneTM Item Description 1 6"/152 mm Square Bar* 2 Patented 1 -Beet® Center Bracket 3 End Bracket FM/VdS approved, cULus listed. 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 8 ✓ctaulic J victaulic.com 4.3 DIMENSIONS (Continued) VicFlex Brackets Style AB11 • Suspended ceilings • Hard -Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented 1 -Beet• Center Bracket 3 End Bracket 'FM/VdS approved, cULus listed. Low Profile Short 90° elbow reducer NOTE • The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. Long 90° elbow reducer • • 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 9 ✓ctaulic° victaulic.com 4.4 DIMENSIONS • CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB1 Bracket Suspended Ceiling Grid with Recessed Sprinkler A See Chart 17/43 mm Typical 001 ing grid •t!AS .11 E E - See note —u INN IN r� ■1 Bracket assembly Style AB1 24'/6 0 mm 0r 4871219 mm on Centel W/16 min Typical g ole 44'/ 113 nm Fin shed ceiling face V2707 3/4'i/19mm Max. Recess 2'm."%60 mm hale '-2751 rcm—' 5 hole Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min. 10.8 273 11.8 299 12.8 324 13.8 349 14.8 375 15.8 400 Suspended Ceiling Grid with Concealed Sprinkler A See Chart Bracket Assembly Style 091 2W7683 nom ax hole 2o/.760 3 min hole hole 44/113 mm 1.7'/43 mm '/./139 mm T ical ceiling t le Typical Jing grid See note Inished 247610 min or 4871219 mm o Ing face on Center V3802'"/12.7mm Max. Recess Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min. 10.1 269 11.1 281 12.1 307 13.1 333 14.1 358 15.1 383 Suspended Ceiling Grid with Recessed Sprinkler with Suspended Ceiling Grid with Concealed Sprinkler with 90° Elbow (Long) V2707 3/4'i/19mm Max. Recess Hose Clearance Chart Dimension inches mm A Min. 8.0 200 • 90° Elbow (Short) V3802' 0/12.7mm Max. Recess Hose Clearance Chart Dimension inches mm A Min. 5.8 147 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 10 . �Ctaulic victaulic.com 4.4 DIMENSIONS (Continued) • CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB2 Bracket Hard -lid Ceiling with Concealed Sprinkler V3802 1/2"/12.7mm Max. Recess Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min. 7.6 193 8.6 218 9.6 244 10.6 269 11.6 295 12.6 320 Hard -lid Ceiling with Recessed Sprinkler V2707 3/a"/19mm Max. Recess Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min. 6.1 155 7.1 180 8.1 206 9.1 231 10.1 256 11.1 282 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. Hard -lid Ceiling Grid with Concealed Sprinkler with Hard -lid Ceiling with Recessed Sprinkler with 90° Elbow (Short) V3802' /12.7mm Max. Recess Hose Clearance Chart Dimension inches mm A Min. 5.0 127 • 90° Elbow (Long) V2707 3/dY19mm Max. Recess Hose Clearance Chart Dimension inches mm A Min. 3.6 91 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 11 • ✓ctaulic' victaulic.com 4.5 DIMENSIONS CLEARANCES WITHIN SIDEWALL Series AH2 Braided Hose and Style AB2 Bracket Horizontal Sidewall Sprinkler V2707 3/4'/19mm Max. Recess Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min. 6.1 155 7.1 180 8.1 206 9.1 231 10.1 256 11.1 282 Horizontal Sidewall Sprinkler with 90° Elbow (Long) / 44' Stud 1 35'/ i9 mm 0 Screw ,ii1 QIP' Brack t asseml* Style 42 167406 mm Stud QC See chat V2707 3/4n/19mm Max. Recess lel <S inm Finished ceiling ace Pm. 60 mm hole 2x/51 mm n hole Hose Clearance Chart Dimension inches mm A Min. 3.6 91 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 12 ✓ctaulic victaulic.com 4.6 DIMENSIONS CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB4 Bracket Hat Furring Channel Grid with Recessed Sprinkler See note r7 it 'a MIN 4111411;*, /.%IS9 mm IiJ Tyyp06I Finished Typical 16/406 mm- erlln nle c Illrg face 34'/610mm on Censer /23 mm Typical ceiling gnd 4 See Chart V2707 344719mm Max. Recess Hose Clearance Chart Dimension inches mm inches mm inches inches mm mm inches mm inches mm R A I Minimum 2 3 4 Bend Radius 50 80 100 Min. 10.3 11.3 12.3 262 287 313 5 125 13.3 338 6 150 14.3 363.5 7 175 15.3 389 Hat Furring Channel Grid with Recessed Sprinkler with Hat Furring Channel Grid with Concealed Sprinkler with 90° Elbow (Long) IMP I� 0 See note .I,.;' 4Tykal ell n1 ole Typkal l6'/404 mm- 34'/010mmon Center Finished ceding face I See Chan '/x%33 mm Typicalcerlrng grid V2707 3A"/19mm Max. Recess 3,mi//60mm Mk 2m/mlmm hole Hose Clearance Chart Dimension inches mm A Min. 8 200 90° Elbow (Short) 16'/406mm- 34'/610 moron Cenre, V2707 3/4"/19mm Max. Recess Hose Clearance Chart Dimension inches mm A Min. 5.9 1 149 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. • • 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 13 \CtauIicr victaulic.com • 4.6 DIMENSIONS (Continued) CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB5 Bracket Hard -lid Ceiling with Recessed Sprinkler A See char LI Mit er ii111011�% 4,;,)3/4716mm �t Typ Drywall 16/406 mm Stud C/C V2707 3/4719mm Max. Recess Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min. 6.1 155 7.1 180 8.1 206 9.1 231 10.1 256 11.1 282 Recessed Pendent with 90° Elbow (Long) V2707 3/a"/19mm Max. Recess Hose Clearance Chart Dimension inches mm A Min. 3.6 91 V38021"/13mm Max. Recess Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min. 7.6 193 8.6 218 9.6 244 10.6 269 11.6 295 12.6 320 Hard -lid Ceiling with Concealed Pendent with 90° Elbow (Short) V3802 W/13mm Max. Recess Hose Clearance Chart Dimension inches mm A Min. 3.3 84 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. • 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 14 • �CtauIicr victaulic.com 4.6 DIMENSIONS (Continued) CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) Suspended Ceiling Grid with Recessed Sprinkler with LP 90° Elbow (Long) A See chart 1.7743 mm Typical ceiling grid See Note Bracket assembly Style AB11 z����r�i�����// • 5/8"/16 mm ,}1 Typical ceiling tile 1 247610 mm or 48"/1219 mm on Center Finished ceiling face V2707 3/4"/19 mm MAX. RECESS Hose Clearance Chart Dimension inches mm A Min. 4.0 100 3"/ 76 mm 23/8"/60 mm max. hole X2"/51 mm min. hole V2707 MAX. EXTENSION Suspended Ceiling Grid with Concealed Pendent with LP 90° Elbow (Short) A See chart 1.7"/43 mm Typical ceiling grid Bracket assembly Style AB11 5/s716 mm{{ Typical ceiling tile 11 See Note 1 24"/610 mm or48"/1210mm on Center Finished Ceiling Face V3802 3"/13 mm MAX. RECESS Hose Clearance Chart Dimension inches mm A Min. 3.9 99 3"/ 76 mm 2"/o"168 mm F max. hole 23/8760 mmm min. hole V3802 MAX. EXTENSION 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 15 �Ctaulicr victaulic.com 4.6 DIMENSIONS (Continued) • CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB3 Bracket Surface Mount Application with Recessed Sprinkler 23/8"/60 mm max. hole 4- -J.. 2"/51 mm min. hole Wall Thickness 2 50 Outlet Length 5.75 9 "B" 146.1 228.6 Hose Cllearances 4 100 13 330.2 5.75 146.1 9 228.6 13 330.2 6 8 150 200 9 13 13 228.6 330.2 330.2 10 250 13 330.2 5.75 146.1 2 50 9 228.6 4 100 6 150 8 200 10 250 13 330.2 5.75 146.1 9 228.6 13 330.2 9 13 13 13 228.6 330.2 330.2 330.2 Hose Clearance "C" 11.6 - 14.8 294 376 18.8 478 9.6 243 12.8 325 16.8 427 10.8 275 14.8 376 12.8 325 10.8 275 12.6 319 15.8 402 19.8 503 10.6 268 13.8 351 17.8 452 11.8 300 15.8 402 13.8 351 11.8 300 Bend Radius 7 175 8 200 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. • See installation instructions for mounting screw type and size. • • 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 16 �CtaUIicr victaulic.com 4.7 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet R See chart Female Threaded Weld Outlet 2"/50 mm A See chart Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min. 8.4 214 9.4 239 10.4 264 11.4 290 12.4 315 13.41 341 • R See chart No. 142 Grooved Weld Outlet 2750 mm See chart Hose Clearance Chart Dimension inches;inches mm mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 3 50 80 4 100 5 125 6 150 7 175 A Min. 7.1 8.1 180 205 9.1 231 10.1 256 11.1 281 12.1 307 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 17 ✓ctaulic victaulic.com 4.7 DIMENSIONS (Continued) BRANCHLINE CLEARANCES Series AH2 Braided Hose with Style 922 threaded outlet R See chart A See chart Style 922 Threaded Mechanical Tee Outlet 2"/50 mm Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min. 8.4 212 9.4 238 10.4 263 11.4 289 12.4 314 13.4 339 Series AH2-CC Braided Hose with Style 922 grooved outlet R See chart A See chart Style 922 Grooved Mechanical Tee Outlet 2"/50 mm Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min. 6.7 171 7.7 197 8.7 222 9.7 247 10.7 273 11.7 298 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 18 • JCtaL1Iic ) victaulic.com • 5.0 PERFORMANCE - FRICTION LOSS DATA • cC) US OSTEO Series AH2 and AH2-CC Braided Hoses with Straight 5.75'1140 mm Reducers Style AB1, AB2, AB4, AB5 and AB10 Brackets 1 inches/mm inches/mm/type Equivalent Length of 1"/33.7 mm Sch. 40 Pipe (C=120) feet/meters Maximum Number of 90° Bends at 2'%51 mm Bend Radius 31/775 1/2715/Straight 16/4.9 4 3/4720/Straight 17/5.2 4 36/900 ' /15/Straight 21/6.4 5 3/4720/Straight 23/7.0 5 48/1200 1/2715/Straight 32/9.8 8 3/4720/Straight 37/11.3 8 60/1500 1/2"/15/Straight 46/14.0 10 3/4720/Straight 46/14.0 10 72/1800 ' /15/Straight 55/16.8 12 _ _ .__ __ 3/4"/20/Straight 53/16.2 12 c CL US USTED Series AH2 Braided Hose with 90° Low Profile Elbows Style AB11 VicFlex Bracket inches/mm inches/mm Equivalent Length of 1'733.7 mm Sch. 40 Pipe feet/meters Maximum Number of 90° Bends at 2"/51 mm Bend Radius 31/775 '/2"/15 24/7.3 4 3/4720 24/7.3 4 36/900 1/2715 26/7.9 5 3/4"/20 28/8.5 5 48/1200 1/2715 43/13.1 8 3/4"/20 42/12.8 8 60/1500 1/2715 S 49/14.9 10 3/4"/20 50/15.2 10 72/1800 1/2715 65/19.8 12 3/4720 63/19.2 12 • 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 19 • j1taUIiC° victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA (Continued) • Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2'/51 mm center line bend radius Length of Stainless Steel Flexible Hose inches/ mm Outlet Size inches/ mm 1 Bend feet/ meters 2 Bends feet/ meters 3 Bends feet/ meters 4 Bends feet/ meters 5 Bends feet/ meters 6 Bends feet/ meters 7 Bends feet/ meters 8 Bends feet/ meters 9 Bends feet/ meters 10 Bends feet/ meters 11 Bends feet/ meters 12 Bends feet/ meters 31/775 W/15 8.5/2.6 11.0/3.4 13.0/4.0 16.0/4.9 N.A N.A N.A N.A N.A N.A N.A N.A N.A _ N.A N.A 3/4"/20 10.0/3.0 12.5/3.8 14.0/4.3 17.0/5.2 N.A N.A N.A N.A N.A 36/900 1/2"/15 13.5/4.1 16.0/4.9 18.0/5.5 19.0/5.8 21.0/6.4 N.A N.A N.A N.A N.A N.A N.A 3/4"/20 14.0/4.3 17.0/5.2 19.5/5.9 20.0/6.1 23.0/7.0 N.A N.A N.A N.A N.A N.A N.A 48/1200 W/15 15.5/4.7 17.0/5.2 19.5/5.9 20.0/6.1 21.0/6.4 22.0/6.7 28.0/8.5 32.0/9.8 N.A N.A N.A N.A 3/x"/20 17.0/5.2 19.0/5.8 21.5/6.6 24.5/75 26.0/7.9 27.0/8.2 30.0/9.1 37.0/11.3 N.A N.A N.A N.A 60/1500 W/15 21.5/6.6 24.0/7.3 27.0/8.2 28.5/8.7 30.0/9.1 31.0/9.4 37.0/11.3 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A 3/020 23.0/7.0 24.0/7.3 28.0/8.5 29.5/9.0 30.5/9.3 31.0/9.4 38.0/11.6 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A 72/1800 W/15 30.0/9.1 32.0/9.8 36.5/11.1 37.5/11.4 40.5/12.5 41.0/12.8 42.0/12.8 46.0/14.0 49.0/14.9 52.0/15.8 54.0/16.5 55.0/16.8 3/4"/20 32.0/9.8 32.5/9.9 35.0/10.7 35.5/10.8 40.0/12.3 40.5/12.3 41.0/12.5 46.0/14.0 50.0/15.2 51.0/15.5 52.0/15.8 53.0/16.2 NOTES: • Values for use with 5.75/140 mm straight reducers. How to use this Design Guide: • For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. • 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 20 \CtauIiCr victaulic.com 5.1 PERFORMANCE — FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses Style AB1, AB2, AB3, AB4, ABS, AB7, AB7 Adj., AB8, AB9 and AB1O VicFlex Brackets Length of Stainless Steel Flexible Hose inches/mm K -Factor Im perial/S.I. Outlet Size inches/mm/type Equivalent Length of 1"/33.7mm Sch. 40 Pipe feet/meters Maximum Number of 90° Bends at 7"/178mm Bend Radius 31/775 5.6/8.11h"/15/90° W/15/Straight 23.5/7.1 2 Elbow 23.5/7.1 36/900 5.6/8.1 1 '/15/Straight 27.8/8.5 2 Y:"/15/90` Elbow 25.6/7.8 48/1200 5.6/8.11/=^/15/90° 1/2715/Straight 38.2/11.6 3 Elbow 30.7/9.3 60/1500 5.6/8.14 1/2715/Straight 42.4/12.9 1/,°/15/90° Elbow 35.9/10.9 72/1800 5.6/8.1ih"/15/90° 1/2715/Straight 46.6/14.2 4 Elbow 41.1/12.5 31/775 8.0/11.52 3/4720/Straight 16.8/5.1 3/4720/90` Elbow 16.8/5.1 36/900 8.0/11.5 3/4"/20/Straight 20/6.0 2 3/4"/20/90° Elbow 19.7/6.0 48/1200 8.0/11.53 3/4"/20/Straight 27.8/8.4 3/4"/20/90° Elbow 26.6/8.1 60/1500 8.0/11.53/4720/90° 3/4"/20/Straight 35.7/10.9 4 Elbow 33.6/10.2 72/1800 8.0/11.53/4°/20/90" 3/4720/Straight 43.5/13.2 4 Elbow 40.6/12.2 31/775 11.2/16.1 3/4"/20/Straight 16.5/5.0 2 3/4"/20/90` Elbow 17.8/5.4 36/900 11.2/16.1 3/4"/20/Straight 19.5/5.9 2 3/4"/20/90° Elbow 20.7/6.3 48/1200 11.2/16.13 3/4720/Straight 26.7/8.1 3/4"/20/90° Elbow 27.9/8.5 60/1500 11.2/16.13/4"/20/90° 3/4720/Straight 33.9/10.3 4 Elbow 35/10.7 72/1800 11.2/16.14 3/4'/20/Straight 41.3/12.5 3/4720/90° Elbow 42.2/12.8 31/775 14.0/20.22 3/4720/Straight 14.9/4.5 3/4"/20/90° Elbow 15.5/4.72 36/900 14.0/20.22 3/4720/Straight 19.4/5.9 3/4720/90° Elbow 19.6/5.9 48/1200 14.0/20.23 3/4720/Straight 30.3/9.2 3/4"/20/90° Elbow 29.5/8.9 60/1500 14.0/20.2Wj20/90° 3/4720/Straight 33.9/10.3 4 Elbow 34.1/10.4 72/1800 14.0/20.24 3/4720/Straight 37.5/11.4 3/4"/20/90° Elbow 38.6/11.7 FM NOTES: • Series AH2 has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 and Vds standards for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • Differences in equivalent lengths are due to varying test methods, per FM 1637 and VdS standards. Refer to these standards for additional information regarding friction loss test methods. • EXAMPLE: A 48 -inch hose installed with two 30° bends and two 90° bends at a 7 -inch bend radius is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. • 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 21 �CtaaUIiC victaulic.com 5.2 PERFORMANCE — FRICTION LOSS DATA Series AH2 Braided Hose with 90° Low Profile Elbows Style AB11 VicFllex Bracket Length of Stainless Steel Flexible Hose inches/mm K -Factor Imperial/S.I. Outlet Size inches/mm Equivalent Length of 1'733.7mm Sch. 40 Pipe feet/meters Maximum Number of 90° Bends at 7'/178mm Bend Radius 31/775 5.6/8.1 '/2"/15 13.7/4.2 2 36/900 5.6/8.1 �h"/15 17.0/5.2 2 48/1200 5.6/8.1 Y2"/15 25.0/7.6 3 60/1500 5.6/8.1 '/2°/15 33.0/10.1 4 72/1800 5.6/8.1 �h"/15 41.1/12.5 4 31/775 8.0/11.5 ;/4°/20 13.6/4.14 2 36/900 8.0/11.5 3/4"/20 16.9/5.2 2 48/1200 8.0/11.5 3/4"/20 27.8/8.5 3 60/1500 8.0/11.5 3/4"/20 32.6/9.9 4 72/1800 8.0/11.5 W/20 40.6/12.4 4 31/775 11.2/16.1 W/20 13.7/4.2 2 36/900 11.2/16.1 3/4"/20 17.0/5.2 2 48/1200 11.2/16.1 3/4"/20 24.9/7.6 3 60/1500 11.2/16.1 3/4"/20 32.9/10.0 4 72/1800 11.2/16.1 3/4"/20 40.9/12.5 4 31/775 14.0/20.2 3/4"/20 13.5/4.1 2 36/900 14.0/20.2 3/4"/20 16.8/5.1 2 48/1200 14.0/20.2 3/4"/20 24.7/7.5 3 60/1500 14.0/20.2 3/4"/20 32.7/9.9 4 72/1800 14.0/20.2 3/4"/20 40.7/12.4 4 FM NOTES: • Series AH2 has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 and Vds standards for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • Differences in equivalent lengths are due to varying test methods, per FM 1637 and VdS standards. Refer to these standards for additional information regarding friction loss test methods. • EXAMPLE: A 48 -inch hose installed with two 30° bends and two 90° bends at a 7 -inch bend radius is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 22 • ✓ctaulic' victaulic.com 5.3 PERFORMANCE - FRICTION LOSS DATA • VdS Series AH2 Braided Hose Style AB1, AB2, AB4, ABS, AB7, AB7 Adj., AB8, AB9, AB10 and AB11 Brackets Length of Stainless Steel Flexible Hose mm/inches Outlet Size mm/inches Series AH2 Hose Equivalent Length of steel pipe according to EN 10255 DN 25 (33,7 x 3,25) meters/feet Maximum Number of 90EBends at 3"/76.2mm Bend Radius meters/feet 775/31 1 Smm/'/z° 5.5/18.0 3 20 mm/3/4" 900/36 15mm/'/z" 6.4/21.0 3 20 mm/3/4" 1200/48 15mm/'/z° 8.5/27.9 3 20 mm/3/4" 1500/60 15mm/'/z" 10.7/35.1 4 20 mm/3/4" 1800/72 15mm/�/z" 12.8/42.0 4 20 mm/3/4" VDS CEILING MANUFACTURERS LIST AB1, AB2, AB7, AB10 ,AB11 AB4/9 1. AMF 2. Armstrong 3. Chicago Metallic 4. Dipling 5. Durlum 6. Geipel 7. Gema -Armstrong 8. Hilti 9. Knauf 10. Lafarge 11. Linder 12. Odenwald 13. Richter 14. Rigips 15. Rockfon Pagos 16. Suckow & Fischer 17. USG Donn LPCB AB5, AB8 No specific approval 1. Hilti 2. Knauf 3. Lafarge 4. Lindner 5. Rigips Series AH2 Braided Hose Style AB1 Bracket Length of Stainless Steel Flexible Hose mm/inches Outlet Size mm/inches/type Series AH2 Hose Maximum Number of 90EBends at 3'%76.2mm Bend Radius Equivalent Length of steel pipe according to EN 10255 DN 25 (33,7 x 3,25) meters/feet 775/31 15mm/'/z"/Straight 1.8/6.0 2 20 mm/3/4'/Straight 900/36 15mm/'/z"/Straight 3.6/11.9 3 20 mm/3/4"/Straight 1200/48 1Smm/'/z"/Straight 4.3/14.0 3 20 mm/3/4"/Strht 1500/60 15mm/'/x"/Straight 4.1/13.6 3 20 mm/3/4"/Straight 1800/72 15mm/1/z"/Straight 5.5/18.1 3 20 mm/3/4"/Straight 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 23 ✓ctaulic victaulic.com 6.0 NOTIFICATIONS A WARNING • It is the responsibility of the system designer to verify suitability of 300 -series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300 -series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. 7.0 REFERENCE MATERIALS — CHARACTERISTICS Flexible Hose In -Plane Bend Characteristics One Bend Minimum bend radius 90°° L Two Bends Minimum bend radius OR Minimum bend radius Three Bends 2X Minimum bend radius Minimum bend radius OR Minimum bend radius Minimum bend radius Minimum bend radius NOTE For out -of -plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicFlex-AB1-AB2-AB 10 I-VicFlex-AB3 I-VicFlex-AB7 I-VicFlex-AB8 I-VicFlex-AB4-AB9 _J User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. • Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to I-VICFLEX-AB1-AB2-AB10, I-VICFLEX-AB4-AB9, I-VICFLEX-AB7, or I-VICFLEX-AB8 for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.85 5839 Rev AA Updated 12/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 24 • �ctaulid F 6 --Ann 1 Q The. AAr.irr.Flr..r I"r. A SHIPPING BAR ;ROOVED11%---# - END} c YL us I' ); . 90 L.R. ELBOW . k `a it•I' , 4 y. a HOSE & `1 r^ ;; FOR FIRE SPRINKLER SYSTEMS 1 = BRAID 180° , = _ 114> APPROVED RETURN �� MATERIALS OF AIR RELEASE%or CONSTRUCTION END FITTINGS - CARBON STEEL - SCH 40/STD WT HOSE & BRAID - STAINLESS STEEL - 300 SERIES 90° ELBOW - CARBON STEEL - SCH 40/STD WT i 180° RETURN - CARBON STEEL - SCH 40/STD WT OR DRAIN PLUG SUPPORT BRACKET (2" AND LARGER) NOTE: METRALOOPS 2-1/2" AND LARGER INSTALLED IN ANY ORIENTATION OTHER THAN HANGING DOWN MUST HAVE THE 180° RETURN SUPPORTED. (SEE INSTALLATION INSTRUCTIONS.) CONTACT FACTORY FOR ADDITIONAL SIZES AND MOVEMENTS. ALL DIMENSIONS IN INCHES. QTY SIZE MODEL MOVEMENT A B PSI WT (LBS) PROJECT INFO 1" (25mm) MLUGFM80100 ±4" 15" 20" 300 8 1.25" (32mm) MLUGFM80125 ±4" 15.75" 21" 300 10 1.5" (40mm) MLUGFM80150 ±4" 17.5" 23" 300 15 2" (50mm) MLUGFM80200 ±4" 20" 25" 300 18 2.5" (65mm) MLUGFM80250 ±4" 21.5" 28" 300 29 3" (80mm) MLUGFM80300 ±4" 24" 30" 300 43 4" (100mm) MLUGFM80400 ±4" 30" 35" 175 60 5" (125mm) MLUGFM80500 ±4" 36" 40" 175 99 6" (150mm) MLUGFM80600 ±4" 42" 46" 175 150 8" (200mm) MLUGFM80800 ±4" 56" 58" 175 286 10" (250mm) MLUGFM81000 ±4" 68" 64" 175 450 12" (300mm) MLUGFM81200 ±4" 80" 73" 175 665 FOR IN DRY PIPE SYSTEMS SUITABLE USE FOR TEMPERATURES TO -40°F. 2 SIZES ADDED 8/21/2018 REV. 1 SUPPORT BRACKET CHANGE DATE 2/5/2015 E\'letra for pipes in motion 2323 W. HUBBARD lex• EH32O838002T. WWW•METRAFIRE.COM :USTOMER: METRAFLEX FIRELOOPTM GROOVED ENDS, ±4" MOVEMENT PROJECT: DRAWN BY: DKISH DATE: 5/30/2014 APPROVED: ZB DATE: 5/30/2014 ENGINEER: SCALE: DRAWING NUMBER: NTS MLUGFM8—REV2 6 --Ann 1 Q The. AAr.irr.Flr..r I"r. METRALOOP WITH SEISMIC BREAKAWAY HANGER (FORMERLY BREAKAWAY COUPLING) IF THE HANGER ROD IS SMALLER THAN THE NUT OF THE SWIVEL HANGER, SIMPLY SLIDE THE UNDERSIZED ROD THROUGH THE NUT AND FASTEN WITH THE APPROPRIATE SIZED NUTS. A CABLE TETHER IS SUPPLIED FOR SUPPORTING LARGE SEISMIC LOOPS WHOSE WEIGHT OR EXTREME FLEXIBILITY MAY REQUIRE SUPPORT. LOCK NUT BY OTHERS ALUMINUM BODY 304 STAINLESS STEEL PIN HANGER ROD BY OTHERS CARBON STEEL SWIVEL WITH "D" UNC NUT (SEE BELOW) C B SEISMIC BREAKAWAY HANGER SIZING CHART LOOP SIZE LOOP MOVEMENT +4" +8" ±16" +24" 1/2" NOT REQUIRED SBH65 SBH65 3/4" SBH65 SBH65 1" SBH65 SBH65 1-1/4" SBH65 SBH65 1-1/2" SBH65 SBH65 2" SBH65 SBH80 2-1/2" SBH80 SBH80 SBH130 3" SBH80 SBH80 SBH130 SBH130 4" SBH130 SBH130 SBH130 SBH200 5" SBH130 SBH130 SBH200 SBH400 6" SBH200 SBH200 SBH400 SBH400 8" SBH400 SBH650 SBH650 SBH650 CUSTOMER: METRALOOP 180° RETURN METRALOOP SUPPORT BRACKET CARBON STEEL NYLON INSERT LOCK NUT A QTY PART # A (in) B (in) C (in) D (in) SBH30 7.25 6.375 2.125 5/8" SBH45 7.25 6.375 2.125 5/8" SBH65 7.25 6.375 2.125 5/8" SBH80 7.25 6.375 2.125 5/8" SBH130 9.75 8.75 2.875 5/8" SBH200 9.75 8.75 2.875 3/4" SBH400 12.75 11.625 2.875 3/4" SBH650 12.75 11.625 2.875 3/4" REV. DATE pt r �IpY 2323 W. HUBBARD ST. I\/1etra FAX: 312-7 83045 2 for pipes in motion WWW.METRAFLEX.COM SEISMIC BREAKAWAY HANGER (FORMERLY BREAKAWAY COUPLING) PROJECT: DRAWN BY: DKISH DATE: 9/25/2018 APPROVED: DATE: ENGINEER: SCALE: DRAWING NUMBER: N/A SBH -4 METRAFLEX SEISMIC BREAKAWAY HANGER OPERATION, INSTALLATION, AND MAINTENANCE INSTRUCTIONS JGeneral: The purpose of the Metraflex Seismic BreakAway Hanger is to support the flexible element of seismic joint such as the Metraloop. During a seismic event, the Seismic BreakAway Hanger will .reak free allowing the seismic joint to freely move in its complete range of motion. After the seismic event, the Metraflex Seismic BreakAway Hanger can be simply reassembled. Application: Each Metraflex Seismic BreakAway Hanger is factory set for a specific load and will be matched to a specific Metraloop or other seismic joint. The Metraflex Seismic BreakAway Hanger is installed in the hanger rod of the seismic joint. For the Metraloop product this will be located at the 180° return fitting. For Dog Leg products this will be at the 90° elbow. For large movement units, Seismic BreakAway Hangers may be required to support the flexible hose, see figure 4 and 4A. Tethers: Tethers are used to prevent the seismic joint from over flexing and are included on all Seismic BreakAway Hangers. Installation: 1. The Metraflex Seismic BreakAway Hanger should be installed as close to the seismic joint as possible. See figure 1. 2. Insure that the correct size Hanger has been selected for installation by reviewing the submittal. 3. The swivel eye bolt should be installed in the top position attached to rod or cable that complies with the contract documents. See figure 1 and 2. 4. A male thread is provided for connection to the seismic joint. See figure 1 and 2. 5. Apply the no step stickers provided with the Hanger to the pipe / insulation cover. .aution: �I . When lifting from the flexible hose, never point load the hose during the installation process, always use a saddle. The hose consists of corrugated stainless steel hose and can be damaged. 2. The Seismic BreakAway Hanger is designed for a specific load based on the size and configuration of the seismic joint. People walking on the seismic joint or other outside loads on the devise can result in premature breaking of the coupling and should be avoided. No Step warning stickers have been provided with the Seismic BreakAway Hanger for larger pipe sizes. 3. When installing a seismic joint with multiple Seismic BreakAway Hangers, evenly lift the seismic device into place. Do not over flex the hose. Testing: Each Seismic BreakAway Hanger is factory tested prior to shipment. No field testing is necessary. Maintenance: The Metraflex Seismic BreakAway Hanger does not require maintenance and there are no serviceable parts. If the Hanger is ever pulled apart, for any reason, simply insert the pin back into the Hanger until it is bottomed out. For Hangers designed to support larger seismic connections a "C- clamp" may be required to push the pin for reassembly. CUSTOMER: PROJECT: ENGINEER: Metra for pipes in motion 2323 W. HUBBARD ST. CHICAGO, IL 60612 XTEL: 312-738-3800 • FAX: 312-738-0415 W W W.METRAFLEX.COM SEISMIC BREAKAWAY HANGER OPERATION, INSTALLATION. AND MAINTENANCE INSTRUCTIONS DRAWN BY: DKISH DATE: 11/12/2015 APPROVED: JC DATE: 11/12/2015 SCALE: N/A DRAWING NUMBER: SBH -01M 1 of 2 METRAFLEX SEISMIC BREAKAWAY HANGER OPERATION, INSTALLATION, AND MAINTENANCE INSTRUCTIONS INSTRUCTIONS CONTINUED: FIGURE 1 LOCK NUT BY OTHERS ALUMINUM BODY 304 STAINLESS STEEL PIN HANGER ROD BY OTHERS CARBON STEEL SWIVEL WITH 5/8" UNC NUT METRALOOP SUPPORT BRACKET CARBON STEEL NYLON INSERT LOCK NUT METRALOOP 180° RETURN FIGURE 4 UNITS CAN ALSO BE USED WITH SADDLES TO PREVENT LONG FLEXIBLE LEGS ON LARGE LOOPS FROM SAGGING. FIGURE 2 IF THE HANGER ROD IS SMALLER THAN THE NUT OF THE SWIVEL HANGER, SIMPLY SLIDE THE SMALLER DIAMETER ROD THROUGH THE NUT AND FASTEN WITH THE APPROPRIATE SIZED NUTS. FIGURE 3 A CABLE TETHER IS SUPPLIED FOR SUPPORTING LARGE DIAMETER SEISMIC LOOPS WHOSE WEIGHT OR EXTREME FLEXIBILITY MAY REQUIRE SUPPORT. CABLE TETHER FIGURE 4A METRAFLEX SEISMIC BREAKAWAY HANGER 180°, 12" LONG, 14 GA GALVINIZED STEEL SADDLE (RECOMMENDED WITH PLASTIC LINER) THREADED ROD CLEVIS HANGER EXISTING SEISMIC FLEX Metra for pipes In motion 2323 W. HUBBARD ST. CHICAGO, IL 60612 XTEL: 312-738-3800 • FAX: 312-738-0415 WWW.METRAFLEX.COM CUSTOMER: SEISMIC BREAKAWAY HANGER OPERATION, INSTALLATION, AND MAINTENANCE INSTRUCTIONS PROJECT: DRAWN BY: DKISH DATE: 11/10/2015 APPROVED: JC DATE: 1 1 /11/2015 ENGINEER: SCALE: DRAWING NUMBER: N/A SBH-OIM 2 of 2 .•••0•.. •••..••. •••••••, COSCO Fire Protection SECTION 2. SPRINKLER HEADS c 0 Bulletin 014 March 2019 e!labia° Model Fl FR Series Quick Response Glass Bulb Sprinklers Model F1 FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall -,....4..I Cs I Model F1 FR56 Recessed Sprinkler Types Standard Spray Pendent 1IVIILUVWcI OILI VVdi1 Model F1 FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1 FR40 Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 Recessed Sprinkler Types Standard Spray Pendent Model F1 FR56LL & F1 FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1 FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. 1. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSI/UL199. 2. FM Approvals (FM) 3. Loss Prevention Certification Board (LPCB) 4. VdS Schadenverhutung GmbH (VdS) 5. Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex G (ULH) 6. EC Certificate: 0786 -CPD -40239 (RA1414), 0786 - CPD -40251 (RA1425), 0786 -CPD -40252 (RA1475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Upright Vertical Sidewall Pendent Conventional Horizontal Sidewall Recessed Pendent/F1/F2 Recessed Horizontal Sidewall XLH Upright Concealed Pendent XLH Pendent Product Description Reliable Model F1 FR series sprinklers are quick -response automatic sprin- klers with a glass bulb thermal element. Model F1 FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model F1 FR56 Conventional sprinkler which is an Old-style/Conven- tional sprinkler. The Model F1 FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR Series sprinklers to apply water to a fire faster than standard -response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely mar ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Recessed Pendent/FP XLH Recessed Pendent F1 /F2 XLH Recessed Pendent FP Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 w c 61-OZ u3RW . At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1FR Series sprinklers provide a wide range of op- tions where quick -response, glass bulb sprinklers are used: • Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors • K -factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) • Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4 -inch (19mm) and 1/2 -inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2 -inch (12.7mm) threaded adjustment. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2 -inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16 -inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k -factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 Ib -ft (11 to 24 N -m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1 FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers have a factory -installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2 -inch (13mm) or 5/8 -inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2 -5/8 -inch (67mm) diameter hole to be cut in the ceiling. The Model GFR2 wrench is used to engage the sprinkler wrench- ing surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plai.e until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick -response Thread Size: 1/2 -inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K -factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inches mm F1FR28 2.8 40 3/8 10 Pendent 2.25 57 W2 RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR56 5.6 80 1/2 cULus, FM, Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 12,34 ,, 15 Upright 2.25 57 W2 RA1425 cULus, FM, LPCB, VdS, EC 12,34 , , "Conventional (Pendent or Upright)" 2.25 57 W2 RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH Concealed Pendent 2.25 57 GFR2 RA1415 cULus, ULH 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 Recessed Horizontal Sidewall 2.63 67 GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2 25 57 W2 RA1485 cULus, FM, LPCB 1,2,3,9 »> cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coatina (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nicke PTFE plating. 13> Available with FM approved Polyester coating in black or white. j4> Available with LPCB and VdS approved Polyester coating. 15> VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2 -inch (12.7mm) adjustment Model CCP cover plate only. (6) Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2 -inch (12.7mm) of adjustment or low profile with 5/16 -inch (8.0 mm) of adjustment. (7) cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (8) cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9) The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. 7 i Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Tem Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141 °C) Temp. Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb F1FR28 Pendent VdS cULus Recessed Pendent Recessed Pendent cULus Upright cULus cULus F1FR40 Pendent cULus, ULH VdS Recessed Pendent RA1410 VdS F1FR42 Pendent cULus cULus Recessed Pendent F1FR56 cULus Upright cULus, FM, LPCB, VdS, EC cULus F1 FR42LL Pendent Recessed Pendent cULus, ULH cULus, ULH cULus, ULH Recessed Pendent F1FR56 Recessed Horizontal Sidewall cULus, ULH cULus, FM F1FRXLH Pendent cULus Recessed Pendent cULus Upright cULus F1FR56 Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC Concealed Pendent* cULus cULus,VdS,EC cULus Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB, VdS, EC F1FR56LL Pendent cULus, ULH Recessed Pendent cULus, ULH Concealed Pendent* cULus, ULH F1 FR56 Horizontal Sidewall cULus, FM Recessed Horizontal Sidewall cULus, FM F1FR56 Vertical Sidewall (Pen dent or Upright) cULus, FM, LPCB * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Model Deflector/ Orientation Listed and Approved Recessed Escutcheons SIN Model F1 (Fig. 1 & 3) 3/4 -inch (19mm) adjustment Model F2 (Fig. 1 & 3) 1/2 -inch (12.7mm) adjustment Model FP (Fig. 2) 1/2 -inch (12.7mm) adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, EC cULus, FM, LPCB, VdS, EC cULus, VdS, EC RA1414 F1FR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS F1 ESCUTCHEON 3/4 [ 19mm] ADJUSTMENT F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT 2 1/4" HOLE DIA. [57.2mm] 1 15/16" DIA [49.2mm] 1" X 1/2" REDUCER 2 27/32" DSA. [72.2mm] 1/8" [3.2mm] FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1 [25.4mm] AT MINIMUM RECESS = 3/8 [9.5mm] / F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4 [19mm] AT MINIMUM RECESS = 3/8 [9.5mm] FI ESCUTCHEON AT MAX/MUM RECESS /AT MINIMUM RECESS = F2 ESCUTCHEON AT MAXIMUM RECESS = AT MINIMUM RECESS = = 7/8[22.2mm] 1-5/8 [41.3mm] 1- 1/8 "[28.6mm] 1-5/8[41.3mm] Fig. 1 Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR40, F1 FR42LL, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon 2 5/8" DIA. [66.7mm] HOLE IN CEILING L�_�__-1 1 f-- ==3_ I I 2 5/16" DIA. [58.7mm] CUP CEILING 1" X 1/2" REDUCER Y2'[12.7mm] ADJUSTMENT 3 1/4" DIA. [82.6mm] FACE OF FITTING TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS = 1-1/2 [38mm] AT MINIMUM RECESS = 1 [25.4mm] AT MAXIMUM RECESS = 9/16"[14.3mm] AT MINIMUM RECESS = 1 '[25.4mm) Fig. 2 Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR40, F1 FR42LL, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1 [25.4mm] AT MINIMUM RECESS = 3/8119.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4[19mm] AT MINIMUM RECESS = 3/8"[9.5mmJ 2 1/4" HOLE DIA. [57.2mm] 1" X 1/2" REDUCER 1/8" [3.2mm] F1 ESCUTCHEON AT MAXIMUM RECESS = AT MINIMUM RECESS = F2 ESCUTCHEON AT MAXIMUM RECESS AT MINIMUM RECESS 1'mm Ow 1 15/ 6" DIA.` IF [49.2mm] / "u 11111\ 11111II 46=m==i;--- "' 1 2 27/32 DIA. [72.2mm] TURN COLLAR UNT/L TIGHT AGAINST SPRINKLER WRENCH BOSS. F1 ESCUTCHEON 3/4"[19mm] ADJUSTMENT 1-3/8 [34.9mm / 2-1/16[52.4mm] = 1-5/8[41.3mm] = 2-1/16"[52.4mm] F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT (1) 4"-12" [101.6mm-304.8mm] CEILING TO DEFLECTOR RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW 2 5/16" DIA CUP CEILING 2 5/8" DIA. HOLE IN CEILING „///, / //,,, , 1/2" MAX. 1 COVER ADJUSTMENT COVER PLATE ASSEMBL Y SPRINKLER 3 5/1 6 " DIA. CONCEALED, 1/2" ADJUSTMENT 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION $ 15/16" 017FG01A Fig. 4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2 -inch (12.7mm) adjustment - Model CCP cover plate 6. 1" x 1/2" REDUCING TEE OR ELBOW 2 5/16" DIA CUP CEILING 5/16" MAX. A COVER ADJUSTMENT 2 5/8" DIA, HOLE IN CEILING / ilii /it iiiiiii'1 COVER PLATE ASSEMBLY SPRINKLER 3 5/16" DIA. CONCEALED. 5/1 6" ADJUSTMENT 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION l 3/4" 017FCO2A Fig. 5 - Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16 -inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model F1FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plater') Bronze Brass Chrome Chrome Plated Chrome Plated White Polyester Coated (4)(6x61 White Painted Glass Special Application Finishes Sprinkler Escutcheon Cover plater') Electroless Nickel PTFE(') Electroless Nickel PTFE Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2)(61 Black Paint Off White Off White(2)(6) Off White Satin Chrome Chrome Dull Chrome Dull 1) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi -gloss, unless specified otherwise. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (6) LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. (7) cULus listed Corrosion Resistant 7. Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 , Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent][Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2 -inch NPT][ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model: [F1][F2][FP] 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2 -inch (12.7mm) adjustment][low profile CCP 5/16 -inch (8.0mm) adjustment] 9. Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the"- \ sprinklers and escutcheons are packaged separately. o HANGERS 0 0 SAMMYS® FOR WOOD SAMMYSe FOR WOOD Vertical Application #14 Black Nut Driver Part # 8113910 #14 SW Red Nut Driver Part # 8114910 Application Not less than 2" nominal width ,(1-1127► Not less than 3' nominal thickness (2-1/2") (depth or side of vertical member) 7*v 8i .!8 iIa Wood Flooring 0" IMEINI LIMN Double Sheetrock Ceiling Go posi VNtIF e.,., liIv8 IP 4/5 i:' SS It , , RLC IY =.'vrrYyp fir/. tp,or 0 'f,NY Product Features • No pre -drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Made in the U.S.A. ()WatWatch a video demonstration at ch Approvals Rod Part Size Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test FM Test Box Case Load (lbs) Load (lbs) Qty Qty ERTJCAk MO 7 MADE IN 14.SA V t SPECIAL NUT DRWER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 114" 8002957 GST 100 1/4 x 1" 210 (7116" OSB) 670 (314" Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 1/4" 8004957 GST 300 114 x 3" 2060 (Fir) 3/8" 8007957 GST 10 1/4 x 1" 210 (7116" OSB) 300 670 (314' Ply) 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20 -SS 1/4 x 2" 1760 (Fir) 850 25 125 3/8" 8009925 GST 25.380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 318" 8069925 GST 30 -SS 1/4 x 3" 2060 (Fir) 25 125 3/8" 8011925 GST 40 1/4 x 4" 2180 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 25 25 25 25 12F. 12:. 125 125 For the most up to date information, visit mn nn.ittv'buildex.com SAMMYS® FOR STEEL SAMMYS° FOR STEEL - Vertical Application #14 Black Nut Driver Part # 8113910 #14 SW Red Nut Driver Part # 8114910 Application Product Features pre- dre11u fed rq • Made with Teks® self -drilling fasteners - no pre -drilling required. • Installs into steel range from 20 gauge — 1/2" thicknesses. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Made in the U.S.A. Watch a video dernonstrabon at www.itwbuildex.com Approvals Rod Part Size Number VERTICAL MOUNT Model Screw Ultimate UL Test FM Test Min Max Box Case Descriptions Pullout (lbs) Load (lbs) Load (lbs) Thick Thick Qty Qty 1/4" 8024957 DSTR 100 * 1/4-20 x 1" TEKS 3 1510 (20 ga.) 1/4' 8025957 DST 100 1/4-14 x 1" TEKS 3 446 (20 ga.) 1/4" 8026957 DST 150 1/4-14 x 1-1/2" TEKS 3 970 (16 ga.) 1/4" 8027957 DST 200 1/4-14 x 2" TEKS 3 446 (20 ga.) 1/4" 8030957 TEK 500 12-24 x 1-1/2" TEKS 5 3125 (3/16") 3/8" 8038957 DSTR 1 * 1/4-20 x 1" TEKS 3 1510 (20 ga.) 1500 1475 3/8" 8037957 DSTR 1-1/2 * 12-24 x 1-1/2" TEKS 5 1510 (3/16") 1500 1475 3/8" 8039957 DSTR 516 5/16-18 x 1-1/4"TEKS 3 2200 (20 ga.) 1500 1475 3/8" 8040957 DST 10 1/4-14 x 1" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8077925 DST 10 -SS 1/4-14 x 1" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) .036"-20 ga .036"-20 ga .036"-20 ga .036"-20 ga .188"-3/16" .036"-20 ga .060"-16 ga. .036"-20 ga 3/16" 3/16" 3/16" 3/16" 1/2" 3/16" 1/2" 3/16" 25 25 25 25 25 25 25 25 125 125 125 125 125 125 125 125 3/8" 8041957 DST 15 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8078925 DST 15 -SS 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8042957 DST 20 1/4-14 x 2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8043957 DST 25 1/4-14 x 2-1/2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8044957 DST 30 1/4-14 x 3" TEKS 3 446 (20 ga.) .036"-20 ga 3116" 25 125 970 (16 ga.) S . O 3/8" 8045957 DST 516 5/16-18 x 1-1/4" TEKS 3 1500 (3/16") 1500 1475 .125"-1/8" 3/16" 25 125 a "O. 3/8" 8046957 TEK 50 12-24 x 1-1/2"TEKS 5 3125 (3/16") 1500 1475 .250"-1/4" 1/2" 25 125 1/2" 8031925 DST 2.0 1/4-14 x 2" TEKS 3 446 (20 ga.) .188"-3/16" 1/4" 25 125 970 (16 ga.) 1/2" 8033925 DSTR 1.0 • 1/4-20 x 1" TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1/2" 8034925 DSTR 5.16 5/16-18 x 1-1/4" TEKS 3 2220 (20 ga.) .036"-20 ga 3/16" 25 125 1/2" 8035925 DST 5.16 5/16-18 x 1-1/4" TEKS 3 1500 (3/16") .125"-1/8" 3/16" 25 125 1/2" 8036925 TEK 5.0 12-24 x 1-1/2" TEKS 5 3125 (3/16") .188"-3/16" 1/2" 25 125 'Includes retaining nut 'ADE W U.S.A SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spinoff feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date nformation, visit www.itwbdildex.com 1 SIDEWINDER° FOR STEEL - Horizontal Application #14 SW Red Nut Driver Part # 8114910 NEM® Application Product Features no pre~dr qreut'red • Made with Teks self -drilling fasteners - no pre -drilling required. • Installs into steel range from 20 gauge — 1/2" thicknesses. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • Made in the U.S.A. Wehh a Wdeo demons mlion el www.itwbuildex.com Approvals Rod Part Size Number Model Screw Ultimate UL Test FM Test Min Max Box Case Descriptions Pullout (lbs) Load (lbs) Load (lbs) Thickness Thickness Qty Qty 1/4" 8047957 SWD 100 1/4-14 x 1" TEKS 3 1477 (16 ga.) 1/4" 8049957 SWDR 100 1/4-20 x 1" TEKS 3 1900 (20 ga.) 3/8" 8050957 SWD 10 1/4-14 x 1" TEKS 3 1477 (16 ga.) 3/8" 8080925 SWD 10 -SS 1/4-14 x 1" TEKS 3 1477 (16 ga.) 318" 8051957 SWD 15 1/4-14 x 1-1/2" TEKS 3 1477 (16 ga.) 3/8" 8052957 SWD 20 1/4-14 x 2"TEKS 3 1477 (16 ga.) 3/8" 8053957 SWD 516 5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.) Q Q 3/8" 8055957 SWDR 1 • 1/4-20 x 1" TEKS 3 1900 (20 ga.) Q. C. 3/8" 8054957 SWDR 1-1/2. 12-24 x 1-1/2" TEKS 5 2375 (3/16") ' 3/8' 8056957 SWDR 516 • 5/16-18 x 1.1/4" TEKS 3 2480 (20 ga.) 3/8" 8057957 SWT 15 12-24 x 1-1/2" TEKS 5 2375 (3/16") "Includes retaining nut .060"-16 ga 3/16" 25 125 .036"-20 ga 3/16" 25 125 .060"-16 ga 3/16" 25 125 .060"-16 ga 3116" 25 125 .060"-16 ga 3/16" 25 125 .060"-16 ga 3/16" 25 125 .036"-20 ga 3/16" 25 125 1500 1475 .036"-20 ga 3/16" 25 125 1500 1475 .188"-3/16" 1/2" 25 125 1500 1475 .036"-20 ga 3/16" 25 125 .188"-3/16" 1/2" 25 125 SAMMYS SWIVEL HEAD' FOR STEEL -Swivel Application #14 Black Nut Driver Part # 8113910 #14 SH Orange Nut Driver Part # 8273910 Application Product Features • Eliminates distortion of threaded rod in sloped roof applications. • Accommodates 3-1/2 x 12 pitch. • Installs into angled z-purlin; allows threaded rod to hang plumb. • Allows 17° deflection from vertical. • Made in the U.S.A. Watch a vkao eonm demonsoaof itwbuildex.co Approvals Rod Part Size Number Model Screw Descriptions Ultimate UL Test FM Test Min Max Box Case Pullout (lbs) Load (lbs) Load (lbs) Thick Thick Qty Qty 7':ir i:. Q•' 3/8" 8137957 SH-DSTR 1* 1/4-20 X 1" 3220 (3116') TEKS 3 Q• 3/8" 8268957 SH-TEK 50 1/2" 8270957 SH-TEK 5.0 1500 1475 .035" 3/16" 25 125 2368 (1/2" steel Vertical) 12-24 x 1-3/4" 1306 (45° off Vertical) 1500 (Vertical) 4" TEKS 5 2281 (3/16" HSS) 850 (45° off Vertical) 2-1/2" 1585 (3/16" HSS 45° off Vertical) 2368 (1/2" steel Vertical) 12-24 x 1-3/4" 1306 (45° off Vertical) TEKS 5 2281 (3/16" HSS) 1585 (3/16" HSS 45° off Vertical) "Does not comply With ROHS requirements / Includes retaining nut 3/16" 1/2" 25 125 3/16" 1/2" 25 125 7 To find a distributor near you. call 800-BUILDEX .14 SA MM Y X -PRESS® Installs into Metal Deck, Purlin, or Tubular Steel 1 SAMMY X -PRESS° - Vertical Application Application Product Features • The Sammy X -Press expands to provide direct vertical attachment in: - light gauge steel deck or purlin (22ga. -118"). • Installs in seconds with Sammy X -Press It Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Made in the U.S.A. Watch a video demonstration ar www.itwbuildex.com) Rod art Approvals Size Number Model luerkr Description Ultimate UL Test UL Min FM Test FM Min Max Box Case Application Pullout (lbs) Load (Ibs) Thick Load (Ibs) Thick Thick Qty Qty ®. 1/4" 8181922 XP 200 Sammy X -Press 200 0 3/8" 8150922 XP 20 3/8" 8153922 XP 35 3/8" 8150922 XP 20 Sammy X -Press 20 1146 (22 ga) 1146 (22 ga) 185 (Luminaire) 250 (Luminaire) .027" .056" 850 (2W Pipe) .027" 185 (Luminaire) .027" 250 (Luminaire) .056" 283 (Conduit & Cable) .029" .125° 25 125 Metal Deck 940 (2" Pipe) .029" 1475 (4" Pipe) .104" .125" 25 125 Metal Deck 1500 (4" Pipe) .060" Sammy 1783 (16 ga) 185 (Luminaire) .029" 940 (2" Ripe) .029" .125" 25 125 Pudin X -Press 35 250 (Luminaire) .056" 1475 (4" Pipe) .104" 416 (Conduit & Cable) .059° Pre -Pour Structural Concrete@ 3000 psi Metal Deck Sammy 1146 (22 ga) 850 (2% Pipe) 25 125 (Pre Pour) X -Press 20 Metal Deck Post -Pour Range II LWCs 35 PCF (Ibs/fP) (Post -Pour) Pre -Pour Structural Concrete @ 3000 pal Post -Pour Range II LWCS 35 PCF (lbs/ f') SIDEWINDER X-PRESSTM - Horizontal Application Application Product Features • The SidewinderX-Press expands to provide • Less jobsite material needed. horizontal attachment in: -16 ga - 3116° steel - purlin, tubular steel. • No retaining nut required. • Installs in seconds with Sammy X -Press It° Tool, • Provides design flexibility. saving time & installation costs. • Made in the U.S.A. • Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof deck, tubular steel, or vapor barrier fabric. (Waith a Video dertansoarion 8) ar�!',�www.ifwbulldex.com Approvals Rod Part Size Number Model Description Ultimate UL Test Pullout (lbs) Load (lbs) UL Min FM Test Max Box Case Thick Load (lbs) Thick Qty Qty Application 3/8" 8293957 SWXP 35 Sidewinder X -Press 35 1250 (3Y:" Pipe) 1798 (16 ga) 80 (Luminaire) .059° 416 (Conduit & Cable) .125" 25 125 Purlin For the most up to date information. visit www.itwbuildex.com NEM® SWIVEL X -PRESS"" - Swivel Application Application Product Features for extreme or variant roof pitches • The Swivel X•Press allows you to hang plumb in extreme roof pitches: - 89° in z-purlin - 45° in metal deck for 12112 pitch • Installs in seconds with Sammy X -Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Made in the U.S.A. Watch a video demonstration8t www.itwbuildex.com Approvals Model Description Rod Part Ultimate Size Number Pullout (lbs) SWIVEL MOUNT UL Test Load (lbs) UL Min FM Test FM Min Max Box Case Application Thick Load (lbs) Thick Thick Qty Qty Q. 0 3180 8294922 SXP 20 3/8" 8295922 SXP 35 Swivel 1061 (22 ga Vert) X -Press 20 829 (45° Off Vert) 750 (2° Pipe) 170 Vertical (Luminaire) 80 @ 45° (Luminaire) .029' 635 (2° Pipe) .029" .125" 25 125 Metal Deck 283 Vertical (Conduit & Cable) 233 @ 45° (Conduit & Cable) 1250 (3-1/2" Pipe) Swivel 1675 (16 ga Vert) 80 @ 90° (Luminaire250 Vertical (Luminaire) X -Press 35 1558 (89° Off Vert) 500 Vertical (Conduit) Cable) 059" 635 (2" Pipe) 029" 125" 25 125 Purlin 333 @ 89° (Conduit & Cable) 112' 8272957 SXP 2.0 Swivel 1061 (22 ga Vert) X -Press 2.0 829 (45° Off Vert) 112' 8271957 SXP 3.5 Swivel 1675 (16 ga Vert) X -Press 3.5 1558 (89° Off Vert) .027" .125" 25 125 Metal D .060" .125° 25 125 Purlin SAMMY X -PRESS IV" Installation Tool Application Product Features • The SammyX-Press expands to provide direct vertical attachment in: - metal deck (22-16 gauge) - z-purlin (18-16 gauge) • Made in the U.S.A. Watch 8 video demonsfmfion 8f www.ifwbuildex.com Part Number Model Description Qty 8194910 8152910 'Tool Includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64" Drill Bit. UXPIT• XPDB Universal X -Press It Tool 25/64" Drill Bit To fina a distributor near you. cal 800-BUILDEX SAMMYS® FOR CONCRETE SAMMVS" FOR CONCRETE - Vertical Application Application Proauct Features • Easy two step process (Drill hole & drive Sammys concrete anchor). • W pre -drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Made in the U.S.A. Watch a video demonstration at www.ifwbuildex.com) Approvals Rod Size Part Number Model Screw Ultimate FM Test Box Case Descriptions Pullout (lbs)' (Load (lbs) Qty Qty VERTICAL MOUNT #14 Black 1/4" 8058957 CST 200 Nut Driver Part # 8113910 O 3/8" 8059957 CST 20 #14SW Red318" 8145925 CST 20 -SS Nut Driver —[ 1/2" 8060925 CST 2 Part # 8114910 5/16 x 1-3/4" 5/16 x 1-3/4" 5/16 x 1.3/4" 5/16x1-3/4" 2400 2400 2400 2400 1475 25 25 25 25 125 125 125 125 Tested in 3000 PSI concrete SIDEWINDER" FOR CONCRETE - Horizontal Application Application Product Features • Easy two step process (Drill hole & drive Sammys concrete anchor). •'/" pre -drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Made in the U.S.A. #14SW Red Nut Driver Part# 8114910 Approvals Rod Part Size Number Model Screw Ultimate FM Test Box Descriptions Pullout (lbs)` (Load (lbs) Qty Case Qty HORIZONTAL MOUNT 1/4" 8062957 SWC 200 3/8" 8061957 SWC 20 U 5/16 x 1-314" 5/16 x 1-3/4" 2450 25 125 2450 1475 25 125 • Tested in 3000 PSI concrete The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information. visa ww,v.itwouildex.com 10 TULCI NIBCO www.tolco.com Revision 12/18/2008 Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range — 1/2" thru 8" pipe Material — Carbon Steel, IMil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. • (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW -H-171 E, Type 10 and Manufacturers Standardization Society SP -69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By — Figure number and pipe size Note — Figure 200R (import) with retainer ring and non -captured knurl nut. US LISTED 3 Fig. 200 21/2" - 8" Fig. 200R 21/s" - 8" Dimensions • Weights Pipe Rod Size Size Inch Metric A B Max. Rec. Approx. Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31 25/8 400 11 3/4 3/8 8mm or 10mm 31A 21/2 400 11 1 3/8 8mm or 1 Omm 3* 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 31/e 21/8 400 14 2 3/8 8mm or lOmm 41 3 400 15 21 3/8 10mm 55/8 41/8 600 27 3 3/8 lOmm 57/8 4 600 29 31 3/8 lOmm 73/8 51/4 600 34 4 3/8 lOmm 73/e 5 1000 35 5 1/2 12mm 91/e 61/4 1250 66 6 1/2 12mm 101/8 6% 1250 73 8 1/2 12mm 131/e 83/4 1250 136 Fig. 200R 112" - 2" 9 OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICIE • 800.786.5266 www.tolco.com 92 TULCiiN www.tolco.com Revision 12/3/2008 (-Fig. 200H - Heavy Duty Band Hanger (for Trapeze) Size Range — 2" thru 4" trapeze pipe size. Used to support up to 8" pipe. For 6" and 8" trapeze pipe, consult factory. Material — Carbon Steel — Pre -Galvanized to G40 Spec Function —Designed primarily to support substantially heavier Toads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased Toads from both above and below the trapeze assembly. Features — Furnished with 3/8" or 1/2" adjusting threaded ring nut. Approvals — Underwriters' Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW -H-171 E, Type 10 and Manufacturers Standardization Society SP -69, Type 10. Maximum Temperature — 650°F Finish — Pre -Galvanized Order By — Figure number, pipe size and rod size. Important Design Note — Because of the icreased loads applied to the trapeze assem- -aly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended*. Dimensions • Weights US LISTED Trapeze Rod Size **Max. Rec. Pipe Size Size A B Load Lbs. 2 3/8 49/16 31/32 1250 2 1 /2 423/32 33/6 1250 21 3/8 56/16 323/32 1250 21/2 1/2 51%2 37/8 1250 3 3/8 53/4 327/32 1250 3 1 /2 57/8 331/32 1250 4 3/8 67/8 47/is 1250 4 1 /2 71/32 419/32 1250 * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13 (2002) Table 9.1.1.6.1 (a and b). ** All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. 93 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com OTS www.tolco.com NIBCO Revision 1/24/2007 Fig. 200WON - "Trimline" Adjustable Band Hanger w/o Swivel Nut f Size Range — 1/2" thru 8" pipe Material — Carbon Steel Function — Recommended for the suspension of fire sprinkler and non -insulated pipe or insulated pipe with Fig. 220 shield. Generally installed with two hex nuts. Features — Flared edges on sizes 1/2" thru 2". Eases installation and protects CPVC pipe from any abrasion. Approvals — Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe. Conforms to Federal Specifications WW -171E, Type 7 and Manufacturers Standardization Society SP -69, Type 7 Maximum Temperature — 650°F Finish — Mil. Galvanized to G-90 Note — Available in Stainless Steel materials Order By — Figure number and pipe size E:1 A c0 us LISTED Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size A B C Load Lbs. WtJ100 1/2 3/8 21 2 400 8 3/4 3/8 21/2 2 400 8 1 3/8 21/8 21/8 400 9 11/4 3/8 33/8 21/2 400 10 11/2 3/8 31/2 21h 400 11 2 3/8 33/4 21h 400 12 21 3/8 51/8 35/8 600 24 3 3/8 5% 31h 600 27 31 3/8 63/4 45/8 600 32 4 3/8 63/4 41/2 1000 33 5 1/2 83/8 51/2 1250 60 6 1/2 93/8 6 1250 68 8 1/2 123/8 8 1250 130 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 94 B3205 - Threaded Rod (right-hand threads - both ends) 832051- Threaded Rod (right & left hand threads) Size Range: 3/a'-16 thru 3'-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°C) Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Part number, rod size, length and finish Threaded Accessories TL Specify Length < 'L' Part No. Standard Thread Size Thread Length TL A in. (mm) Design Load 650°F (343°C) 750°F (399°C) Lbs. (kN) Lbs. (khl) 83205-3/e x B3205-1/2 x 'L' 83205-5/e x'L' B3205-3/4 x B3205-7/8 x 'L' B3205-1 x 'L' B3205-11/8 x '1' B3205-11/4 x 'L' 83205-11/2 x B3205-13/4 x 'L' 83205-2 x '1' B3205-21/4 x 'L' 83205-21/2 x'1' B3205-23/4 x 'L' B3205-3 x 318"-16 1/2"-13 5/8"-11 3/4'-10 1/8"-9 1"-8 11/8"-7 11/4"-1 11/2"-6 13/4"-5 2"-41/2 21/4"-41/2 21/2"-4 23/4"-4 3"-4 21/2, 21/2" 21/2" 3" 31/2" 4" 41/2" 5" 6" 7" 8° 9" 10" 11" 12" (63.5) (63.5) (63.5) (76.2) (88.9) (101.6) (114.31 (127.0) (152.4) (177.8) (203.21 (228.6) (254.0) (279.4) (304.8) 730 1350 2160 3230 4480 5900 7450 9500 13800 18600 24600 32300 39800 49400 60100 (3.25) (6.00) (9.61) (14.37) (19.93) (26.24) (33.14) (42.25) (61.38) (82.73) (109.42) 1143.67) (177.03) (219.73) (267.32) 572 1057 1692 2530 3508 4620 5830 7440 10807 14566 19625 25295 31169 38687 47066 (2.54) (4.70) (7.52) (11.25) (15.60) (20 55) (25.93) (33.69) (48971 (64.791 (87.29) (112.51) (138.64) (172.08) (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths Fig. 99 - All Threaded Rod Cut To Length Size Range: 3/a'-16 thru 1 1/2"-6 rod in 120" (3.05m) lengths or cut to length Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Part number, rod diameter and finish Part No. - Size x Length ATR Fig.99 Threads Recommended Load Per Inch Lbs. (kN) Approx. Wt./100 Ft. Lbs. (kg) ATR 1/4"x120 ATR 3/8" x 120 ATR 1/2" x 120 ATR 5/8" x 120 ATR 3/4"x120 ATR 3/4" x 120 ATR1"x120 ATR 11/a" x 120 ATR 11/4" x 120 ATR 1112" x 120 99-1/4" x length 99-3/4" x length 99-1/2" x length 99-3/4" x length 99-3/4" x length 99-7/a" x length 99-1" x length 99-11/a" x length 99-11/4" x length 99-11/2" x length 20 16 13 11 10 9 8 7 7 6 240 730 1350 2160 3230 4480 5900 7450 9500 13800 (1.07) (3.24) (6.00) (9.60) (14.37) (19.93) (26.24) (33.14) (42.25) (61.38) 12 29 53 89 123 170 225 280 351 510 (5.44) (13.15) (24.04) (40.37) 155.791 (77.111 (102.061 (127.01) (159.21) (231.33) All dimensions in charts and on drawings are in B -Line series Pipe Hangers & Supports inches. Dimensions shown in parentheses are 238 in millimeters unless otherwise specified. Eaton RED HAWK Fire & Security Customer: KolKay Electric Inc PO box 459 Ravensdale, WA, 98051 21312 30th Drive SE, Suite 103, Bothell, WA. 98021 Phone: (425) 486-2600 Fax: (425) 486-2611 Visit us online at: www.redhawkus.com Date: 8/14/2019 Site ID: 213651-0004 Job #: 19-1129 System Type: 01 Fire - Detection Project: Thorndyke Elementary 4415 5 150th St Tukwila, WA, 98188 Item Manufacture Model Material List of Data Sheets Description 1 Notifier 2 Notifier 3 Notifier 4 System Sensor FSP -8511V B210LP FCPS-24S8 PC2WL SCWL Intelligent Photoelectric Smoke Detector: White Intelligent Detector Base: White Remote 8A NAC Power Supply; 4- 3.0A Outputs Ceiling Horn w/ Strobe, Multi -cd (15, 30, 75, 95, 110, 150 or 177cd) Ceiling Strobe, Multi -cd (15, 30, 75, 95, 110, 150 or 177cd) © COPYRIGHT REDHAWK FIRE & SECURITY SEATTLE: ALL RIGHTS RESERVED. 0 0 J 0 Ls0 l¢� 0 (1-) 0 U PLOT DATE: 14 -Aug -2019 NDYKE E.S. RENOVATION & MODULAR ADDITION EXISTING FIRE ALARM EXPANSION 4415 SOUTH 150TH STREET, TU KWI LA , WA 98188 SYMBOL LEGEND SYMBOL QTY DESCRIPTION MOUNTING REQUIREMENTS SUPPLIER PART NUMBER FIRE ALARM SPECIFIC NOTES: 4 INTELLIGENT PHOTO SMOKE DETECTOR 4 SQUARE DEEP w/ 3" ROUND RING Output 13 NAC Sync N2-3 Output ;/4 NAC Sync N2-4 NOTIFIER Total Qty FSP -8511V w/ 6210LP 0.0910 0.1450 1 REMOTE NAC POWER SUPPLY w/ ONBOARD FCM-1 8.0A, 4- 3.0A NAC & 1- 0.5A AUX POWER PART INCLUDE BACKBOX; SURFACE MOUNT -3 NAC OUT ADDRESS: 21312 30TH DRIVE SE, SUITE #103 NOTIFIER 1 FCPS-24S8 w/ FCM-1 FCPS8 PC2WL (30) Ceiling Horn w/ Strobe set at 30cd 0.0000 0.0900 CEILING HORN w/ STROBE: WHITE 4 SQUARE DEEP; CENTER ON CEILING TILE PROJECT MANAGER: KATIE McKELLAR katie.mckellar#redhawkus.com EXT: 1447 0 PC2WL (75) Ceiling Horn w/ Strobe set at 75cd 0.0000 0.1430 ^ 3 SEE DEVICE DESIGNATION FOR STROBE cd SETTING 2 THE SAME FIELD ADDRESS 2 SYSTEM SENSOR 0.0000 0.1650 PC2WL i iiC°i. 3 CEILING STROBE: WHITE SEE DEVICE DESIGNATION FOR STROBE cd SEIZING 4 SQUARE DEEP; CENTER ON CEILING TILE 0 PC2WL (115) Ceiling Horn w/ Strobe set at 115cd SYSTEM SENSOR SCWL ,i' 0 SCWL (15) Ceiling Strobe set at 15cd 0.0000 0.0410 6 DEVICE ADRESS 10127 NOTES: Y 3 SCWL (30) Ceiling Strobe set at 30cd 1- DEVICE SUBSCRIPT: NW=NEW RR=REMOVE & RELOCATE EX=EXISITNG TO REMAIN AC=ABOVE CEILING RB=RELAY BASE WP=WATERPROOF WG=WIRE GUARD 000RE5SE6fa0ANOABOVE 2- CABLEING SHOWN IS FOR CIRCUIT REFERENCE ONLY AND DOES NOT INTENDED TO INDICATE THE EXACT PATHWAY. sum 0 SCWL (75) Ceiling Strobe set at 75cd 3- DEVICES SHOWN ON DRAWINGS IN GRAY SCALE ARE EXISTING DEVICES AND MAY NOT BE INCLUDED IN THIS SYMBOL LEGEND UNLESS NOTED. A ? i 4- SET HORN/STROBE DECIBLE SETTING TO LOW FROM FACTORY SETTING OF HIGH, ONLESS OTHERWISE NOTED ON THE DRAWINGS._1r ? 0 . . 1, 5- ALL DEVICES WITH A WP SUBSCRIPT WILL REQUIRE THE USE OF A OUTDOOR OR WP BACKBOX. OB21OLP Y� ti' M.UCR' SLC OUT L iL ! _ `""� ACCE JR' Without Comments ❑ As Noted in Red ❑ Per The Attached Letter ase plans have been reviewed by The Tukwila Fire :noon Bureau =f:. conformance with current City _1dards. Acce czcze.- is subject to errors and .ssiOns which ch_. tthorize violations of adopted 1`dards anti ,rhe respons!_{ i ? ' for the sauacy of des±;:-- ilotally with the designer. •iitions, deletions co revisions to these drawings after is date will void tr;L acceptance and +r`/lil require a esui;mlttai of r wi_ _.4t„ f subsedtient approval. Final acceptance is secco 1 1d test and Inspection by The Tukwila Fire Pt even; 3uraau. Date: S4")- a -1 5 By: �c1•-, i- l I Fire Permit Number Tos t-IL✓Jul,,!. Call 206-573-4407 'F' That,L1 Iv►4 r. t 4-4-Z0 tt. /t) Li 44 o. Itfl7 144 ' NAC Circuit Load, Voltage Drop & Battery Load Calculations APS -2 APS Name: Location: P.S. Type: Part 7: APS -2 FIRE ALARM SPECIFIC NOTES: Standby: Alarm: Circuit Identifers: Output 11 NAC Sync N2-1 Output #2 NAC Sync N2-2 Output 13 NAC Sync N2-3 Output ;/4 NAC Sync N2-4 Aux Power Total Qty MECH RM 114 FCPS-24S8 Description: 0.0910 0.1450 EMAIL rtaylor@kolkay.com PC2WL (15) Ceiling Horn w/ Strobe set at 15cd 0.0000 0.0710 -3 NAC OUT ADDRESS: 21312 30TH DRIVE SE, SUITE #103 BASE 10 ADDRESS 1 _ 1 PC2WL (30) Ceiling Horn w/ Strobe set at 30cd 0.0000 0.0900 SALESMAN: JOE SKVARLA THE DETECTOR & ON PROJECT MANAGER: KATIE McKELLAR katie.mckellar#redhawkus.com EXT: 1447 0 PC2WL (75) Ceiling Horn w/ Strobe set at 75cd 0.0000 0.1430 ^ DETECTOR or MODULE 2 THE SAME FIELD ADDRESS 2 PC2WL (95) Ceiling Horn w/ Strobe set at 95cd 0.0000 0.1650 w..--- -e; i iiC°i. f ---- - 0 PC2WL (115) Ceiling Horn w/ Strobe set at 115cd 0.0000 0.1870 ,i' 0 SCWL (15) Ceiling Strobe set at 15cd 0.0000 0.0410 6 DEVICE ADRESS 10127 3 Y 3 SCWL (30) Ceiling Strobe set at 30cd 0.0000 0.0630 NFS2-640 = 159 DET + 159 MOD (2 L00P 000RE5SE6fa0ANOABOVE 02-3030 = 159 DET + 159 MOD (10 LOOP) sum 0 SCWL (75) Ceiling Strobe set at 75cd 0.0000 0.1110 A ? ? A ? 0 SCWL (95) Ceiling Strobe set at 95cd 0.0000 0.1340 OB21OLP Y� ti' M.UCR' SLC OUT L iL ! STROBE: L.F. SOUNDER: AUDIO ONLY: , y 0 SCWL (115) Ceiling Strobe set at 115cd 0.0000 0.1580 5 = 15cd 9 = 95cd 50 = 150cd L3 =135cd M = MINI HORN 3 = 30cd 0 :110cd 77 =177cd L5 =150cd H = HORN ONLY 6 : 60cd 15 :115cd 85 :185cd L7 =177cd F = SPEAKER ONLY 7 = 75cd 35 =135cd L8 =185cd LF : LOW FREQUENCY 6 = 6" BELL 8 = 8" BELL 10 =10" BELL 12 =12" BELL NOTE: A'WP' ADJACENT TO THE DEVICE INDICATES THAT THE DEVICE IS OUTDOOR RATED 0 P2WL (15) Wall Hom w/ Strobe set at 15cd 0.0000 0.0540 Z /ice �\ I H , y DETECTOR CIRCUIT TYPE: lam,:, CCCC1 1:11•, 0 P2WL (30) Wall Hom w/ Strobe set at 30cd 0.0000 0.0740 1 1 '----- 7 1 i o.L ,' .-1�5f--1 ' I f w l 4 f 0 P2WL (75) Wall Hom w/ Strobe set at 75cd 0.0000 0.1210 :E_===____ `� -t {;�- POWER SUPPLY :`` ,= -ter ' . 1 i ;� / I I. I I 'N" =APS NAC CRCUIT 0 P2WL (95) Wall Hom w/ Strobe set at 95cd 0.0000 0.1420 °'''" II t EA'' "P" = 24VDC POWER CIRCUIT a 4 NAC OUTPUT #1 �I s r"s! i 0 P2WL (115) Wall Hom w/ Strobe set at 110cd 0.0000 0.1620 SYNC OUT 'R" = 24VDC RESET POWER CIRCUIT FCPS24-Sx SERIES NAC POWER SUPPLY- WIRED FOR GENERAL ALARM OPERATION0 ()STROBE QBACKBOX ADVANCE COMBINATION HORN -STROBE via FCPS NAC POWER SUPPLY )SCALE: 0 SWL (15) Wall Strobe set at 15cd 0.0000 0.0430 - "S" = STROBE CIRCUIT i w 1 I 0 SWL (30) Wall Strobe set at 30cd 0.0000 0.0630 NIA 2 COMPLETE CIRCUIT # CIRCUIT 0 SWL (75) Wall Strobe set at 75cd 0.0000 0.1070 2 2 LOW TEMPORAL 3 -- 6 LOW TEMPORAL CHIME III -- --_ 5 - 0 SWL (95) Wall Strobe set at 95cd 0.0000 0.1210 0 SWL (115) Wall Strobe set at 110cd 0.0000 0.1480 0 Typical Door Holders 0.0680 0.0000 0 # Devices per Circuit: Total Standby Circuit Calculated Amps (3): Total Alarm Circuit Calculated Amps (1): Wire Gauge Used (awg): Circuit Length (ft): Estimated Voltage Drop (dc): Estimated EOL Voltage (dc): Calculated Voltage Drop %:_ 0 0 0 6 0 6 0.000 0.000 0.000 0.000 0.0000 0.0910 0.000 0.000 0.000 0.480 0.0000 0.1450 14AWG 14AWG 14AWG 14AWG 14AWG Total Amps Required 0.480 0 0 0 475 0 0.00 0.00 0.00 1.19 0.00 24.00 24.00 24.00 22.81 24.00 0.0% 0.0% 0.0% 4.9% 0.0% 1) Current Draw Measurement based on: UL1971, 16-33V, DC, High db & Temporal Patten 2) Some Outdoor/WP Devices have the same Measured Current Draw as the Indoor Devices and may not listed separately above. 3) When the APS is configured for 'Doors°, Output 14 shutsdown on loss of AC Power. Therefore no "Standby" Current Draw is shown BATTERY LOAD CALC for APS -2: NAC P.S. Max Rating: Total Standby Current: Total Alarm Current: Spare Circuit Capacity: Spare Battery Load Factor: 8.000 Total Amps Required: Total Hours Total Hours Minimum Spare Actual Total AH 0.480 % Used: Standby (AH): Alarm (AH): Needed (AH): Required: Required (AH): Supplied: =1 6% MAXIMUM Required for Required for Battery Sze Battery Capacity Battery Size Rated Batteries Hours Standby: 24 0.0910 2.2 Minutes Alarm: 15 0.6250 0.2 _ Backup Generator? No 2.3 Voice Evacuation? No 20% 0.5 Military No 20% 2.8 CHARGER CAPACITY IS: 18AH 7,0 Cartes c, t' eiafr DEVICE DESIGNATION LEGEND: NOTIFIER ONYX SERIES ADDRESSABLE INITIATING DEVICES: 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ's, NEC AND CONTRACT DRAWINGS 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 4. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL/ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICE PER ELECTRICAL/ARCHITECTURAL PLANS. 5. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND PROPER "END -OF -LINE" RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO REDHAWK FIRE & SECURITY FIELD TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP & CHECKOUT. 6. AS-BUILTS: 6.1. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY REDHAWK FIRE & SECURITY TECHNICIAN. 6.2. AS-BUILTS SHALL BE KEPT ORDERLY AND BE CLEARLY MARKED WITH DIFFERENT COLOR PENS FOR EACH CIRCUIT AND/OR CIRCUIT TYPE. AS-BUILTS MUST INDICATE CHANGES TO THE FINAL DEVICE INSTALLED LOCATIONS IF NOT INSTALLED AT LOCATION SHOWN ON DESIGN DOCUMENTS. 6.3. AS -BUILT REDLINES NOT PROVIDING THIS INFORMATION WILL BE RETURNED TO THE INSTALLATION CONTRACTOR FOR CORRECTION. REDHAWK FIRE & SECURITY IS NOT RESPONSIBLE FOR THESE DELAYS. 7. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH REDHAWK FIRE & SECURITY PROJECT MANAGER. 8. ALL REDHAWK FIRE & SECURITY FIELD SERVICES MUST BE SCHEDULED WITH REDHAWK FIRE & SECURITY PROJECT MANAGER WITH A MINIMUM OF 14 WORKING DAYS ADVANCE NOTICE. 9. DO NOT INSTALL LINE VOLTAGE IN SAME CONDUIT AS POWER LIMITED CABLES. FIRE ALARM SPECIFIC NOTES: 1. SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN 36" OF ANY AIR DIFFUSER. 2. 2013 NFPA 72-17.7.1.11 REQUIRES THAT SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. 2.1. ANY SMOKE DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED AND WILL BE INVOICED ON A T&M BASIS. 3. WALL MOUNTED NOTIFICATION DEVICES BACKBOX BETWEEN A MINIMUM OF 80" AFF TO A MAXIMUM OF 96" AFF. 3.1. DEVICES THAT ARE UNABLE TO BE MOUNTED WHIN THAT RANGE MUST BE VERIFIED BY REDHAWK FIRE & SECURITY PRIOR TO INSTALLATION. 3.2. SEE FLOOR PLANS FOR CANDELA RATING OF EACH DEVICE INSTALLED. 4. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED AT A HEIGHT NO GREATER THAN 48" TO TOP AND NO LOWER THAN 36" TO BOTTOM (PER ADA REQUIREMENTS). - 5. FIELD VERIFY ALL SPRINKLER MONITORING DEVICES WITH FIRE PROTECTION CONTRACTOR 6. FIELD VERIFY ALL HVAC, FAN CONTROL, FIRE/SMOKE DAMPERS AND DUCT DETECTORS LOCATIONS WITH MECHANICAL CONTRACTOR 7. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF REDHAWK FIRE & SECURITY TECHNICIANS. 8. NO TAPPING OF SIGNALING OR INFI1ATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT FACP ONLY. 8.1. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIES TO GROUND ONLY AT THE FACP BY THE REDHAWK FIRE & SECURITY FIELD TECHNICIAN. 9. THE SYSTEM SHALL BE MONITORED BY A U.L. LISTED MONITORING STATION BEFORE AHJ TEST. 10. AS-BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. REDHAWK FIRE & SECURITY REQUIRED ELECTRICAL RED LINES WITHIN 2 WEEKS PRIOR TO AHJ TESTS. 10.1. EACH CIRCUIT (SLC, NAC OR POWER) MUST BE CLEARLY IDENTIFIED WITH A DISTINCT COLOR 10.2. EACH NAC CIRCUIT MUST BE CLEARLY MARKED AS TO WHICH DEVICES ARE ON EACH CIRCUIT AND IN THE ORDER THE DEVICES ARE WIRED TO COMPLETE THE CIRCUIT. RAVENSDALE WA 98051 BASE 1 ADDRESS CONTACT: RENEE TAYLOR MAIN FLOOR AREA B FIRE ALARM EXPANSION PHONE 360-886-1743 -- FAX: 4.7K 'i r-- j EMAIL rtaylor@kolkay.com FIRE ALARM I LIFE SAFETY PROVIDER: NAME: REDHAWK FIRE & SECURITY -3 NAC OUT ADDRESS: 21312 30TH DRIVE SE, SUITE #103 BASE 10 ADDRESS BOTHELL, WA 98021 _ MODULES FAX: 425-486-2611 SALESMAN: JOE SKVARLA THE DETECTOR & ON PROJECT MANAGER: KATIE McKELLAR katie.mckellar#redhawkus.com EXT: 1447 DESIGNER: BRIAN VANDERHEYDEN brian.vanderheyden@redhawkus.com EXT: 1433 ONYX SERIES MAY HAVE ^ DETECTOR or MODULE THE SAME FIELD ADDRESS I FR SOURCE 1 II i -I 1 IiI ic.., s.�l w..--- -e; i iiC°i. f ---- - FOR EXAMPLE: LOOP NUMBER (SLC) ,i' D D D COMPLETEO 6 DEVICE ADRESS 10127 s ��1�7 Y 1IM NFS-320 = 159 DET + 159 MOD 1 L00P Y R�aavETA6ON NFS2-640 = 159 DET + 159 MOD (2 L00P 000RE5SE6fa0ANOABOVE 02-3030 = 159 DET + 159 MOD (10 LOOP) sum NOTIFICATION APPLIANCES: V v (n \ A ? ? A ? �� -r OB21OLP Y� ti' M.UCR' SLC OUT L iL ! STROBE: L.F. SOUNDER: AUDIO ONLY: , y BELL DESINGATION: SLC IN �/� 5 = 15cd 9 = 95cd 50 = 150cd L3 =135cd M = MINI HORN 3 = 30cd 0 :110cd 77 =177cd L5 =150cd H = HORN ONLY 6 : 60cd 15 :115cd 85 :185cd L7 =177cd F = SPEAKER ONLY 7 = 75cd 35 =135cd L8 =185cd LF : LOW FREQUENCY 6 = 6" BELL 8 = 8" BELL 10 =10" BELL 12 =12" BELL NOTE: A'WP' ADJACENT TO THE DEVICE INDICATES THAT THE DEVICE IS OUTDOOR RATED NOTIFICATION /VISUAL CIRCUITS: Z /ice �\ I H , y DETECTOR CIRCUIT TYPE: lam,:, CCCC1 1:11•, FLOOR THAT P.S. IS ON ` -0P CIES sR s-. 1 1 '----- 7 1 i o.L ,' .-1�5f--1 ' I f w l 4 f 'C" = FACP NAC CIRCUIT :E_===____ `� -t {;�- POWER SUPPLY :`` ,= -ter ' . 1 i ;� / I I. I I 'N" =APS NAC CRCUIT S -- . *-!•:------i j °'''" II t EA'' "P" = 24VDC POWER CIRCUIT a 4 NAC OUTPUT #1 �I s r"s! i \ ! , y,e�. =''��/ j i II i" ° SUB NUMBER SYNC OUT 'R" = 24VDC RESET POWER CIRCUIT FCPS24-Sx SERIES NAC POWER SUPPLY- WIRED FOR GENERAL ALARM OPERATION0 ()STROBE QBACKBOX ADVANCE COMBINATION HORN -STROBE via FCPS NAC POWER SUPPLY )SCALE: B D B210LP DETECTOR BASE w/ & w/o THE RA100Z REMOTE INDICATOR & BACKBOX MOUNTING ISOMETRICSSPECTRALERT -CIRCUIT SCALE: NONE LAST MODIFIED ON: OCT Ot 2015 FILENAME: FA-DTL1.6.1 REVISION: 10 ()SCALE: NONE LAST MODIFIED ON FILENAME REVISION "S" = STROBE CIRCUIT i w 1 'V" =VOICEISPEAKER CIRCUIT "T = AUDIO RISER ©OO _ O 2 NIA 2 COMPLETE CIRCUIT # CIRCUIT SYSTEM SENSOR HORNS & CHIMES AUDIO SELECTOR 'L" SERIES DEVICES HORN CHIME WHEELOCK HORNS: EXCEEDER SERIES DEVICES - 2 2 LOW TEMPORAL 3 -- 6 LOW TEMPORAL CHIME III -- --_ 5 - INSTALLATION & GENERAL WIRING NOTES: GENERAL NOTES: 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ's, NEC AND CONTRACT DRAWINGS 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 4. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL/ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICE PER ELECTRICAL/ARCHITECTURAL PLANS. 5. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND PROPER "END -OF -LINE" RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO REDHAWK FIRE & SECURITY FIELD TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP & CHECKOUT. 6. AS-BUILTS: 6.1. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY REDHAWK FIRE & SECURITY TECHNICIAN. 6.2. AS-BUILTS SHALL BE KEPT ORDERLY AND BE CLEARLY MARKED WITH DIFFERENT COLOR PENS FOR EACH CIRCUIT AND/OR CIRCUIT TYPE. AS-BUILTS MUST INDICATE CHANGES TO THE FINAL DEVICE INSTALLED LOCATIONS IF NOT INSTALLED AT LOCATION SHOWN ON DESIGN DOCUMENTS. 6.3. AS -BUILT REDLINES NOT PROVIDING THIS INFORMATION WILL BE RETURNED TO THE INSTALLATION CONTRACTOR FOR CORRECTION. REDHAWK FIRE & SECURITY IS NOT RESPONSIBLE FOR THESE DELAYS. 7. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH REDHAWK FIRE & SECURITY PROJECT MANAGER. 8. ALL REDHAWK FIRE & SECURITY FIELD SERVICES MUST BE SCHEDULED WITH REDHAWK FIRE & SECURITY PROJECT MANAGER WITH A MINIMUM OF 14 WORKING DAYS ADVANCE NOTICE. 9. DO NOT INSTALL LINE VOLTAGE IN SAME CONDUIT AS POWER LIMITED CABLES. FIRE ALARM SPECIFIC NOTES: 1. SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN 36" OF ANY AIR DIFFUSER. 2. 2013 NFPA 72-17.7.1.11 REQUIRES THAT SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. 2.1. ANY SMOKE DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED AND WILL BE INVOICED ON A T&M BASIS. 3. WALL MOUNTED NOTIFICATION DEVICES BACKBOX BETWEEN A MINIMUM OF 80" AFF TO A MAXIMUM OF 96" AFF. 3.1. DEVICES THAT ARE UNABLE TO BE MOUNTED WHIN THAT RANGE MUST BE VERIFIED BY REDHAWK FIRE & SECURITY PRIOR TO INSTALLATION. 3.2. SEE FLOOR PLANS FOR CANDELA RATING OF EACH DEVICE INSTALLED. 4. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED AT A HEIGHT NO GREATER THAN 48" TO TOP AND NO LOWER THAN 36" TO BOTTOM (PER ADA REQUIREMENTS). - 5. FIELD VERIFY ALL SPRINKLER MONITORING DEVICES WITH FIRE PROTECTION CONTRACTOR 6. FIELD VERIFY ALL HVAC, FAN CONTROL, FIRE/SMOKE DAMPERS AND DUCT DETECTORS LOCATIONS WITH MECHANICAL CONTRACTOR 7. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF REDHAWK FIRE & SECURITY TECHNICIANS. 8. NO TAPPING OF SIGNALING OR INFI1ATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT FACP ONLY. 8.1. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIES TO GROUND ONLY AT THE FACP BY THE REDHAWK FIRE & SECURITY FIELD TECHNICIAN. 9. THE SYSTEM SHALL BE MONITORED BY A U.L. LISTED MONITORING STATION BEFORE AHJ TEST. 10. AS-BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. REDHAWK FIRE & SECURITY REQUIRED ELECTRICAL RED LINES WITHIN 2 WEEKS PRIOR TO AHJ TESTS. 10.1. EACH CIRCUIT (SLC, NAC OR POWER) MUST BE CLEARLY IDENTIFIED WITH A DISTINCT COLOR 10.2. EACH NAC CIRCUIT MUST BE CLEARLY MARKED AS TO WHICH DEVICES ARE ON EACH CIRCUIT AND IN THE ORDER THE DEVICES ARE WIRED TO COMPLETE THE CIRCUIT. PROJECT CONTACT INFORMATION: CUSTOMER: NAME: KOLKAY ELECTRIC DESCRIPTION ADDRESS: PO BOX 459 FA0.00 RAVENSDALE WA 98051 2 CONTACT: RENEE TAYLOR MAIN FLOOR AREA B FIRE ALARM EXPANSION PHONE 360-886-1743 -- FAX: 4.7K 'i r-- j EMAIL rtaylor@kolkay.com FIRE ALARM I LIFE SAFETY PROVIDER: NAME: REDHAWK FIRE & SECURITY -3 NAC OUT ADDRESS: 21312 30TH DRIVE SE, SUITE #103 BOTHELL, WA 98021 _ PHONE: 425-486-2600 FAX: 425-486-2611 SALESMAN: JOE SKVARLA joe.skvarla@redhawkus.com EXT: 1437 PROJECT MANAGER: KATIE McKELLAR katie.mckellar#redhawkus.com EXT: 1447 DESIGNER: BRIAN VANDERHEYDEN brian.vanderheyden@redhawkus.com EXT: 1433 SHEET SCHEDULE: PAGE # SHEET # DESCRIPTION 1 FA0.00 GENERAL NOTES & INFO 2 FA1.01 MAIN FLOOR AREA B FIRE ALARM EXPANSION -- -- -- End of List -- N.I.C.E.T. CERTIFICATION STATEMENT 1. THESE FIRE ALARM DRAWINGS HAVE BEEN REVIEWED PER THE SHEET SCHEDULE NOTED ABOVE. 2. 3. BRIAN VANDERHEYDEN DATE SIGNED: 08/i4/20ty CONTROL LOG #: 2o-19 EXPIRES: 10/03/2021 AHJ APPROVALS: CCCC NAC OUT 0 SLC IN : - / ' r ' '- `=.' I L' € 1 `'r"(� \ DETECTOR BASE D SLC OUT \ \ '' \ 1 i I % % _ DEEP BOX -4 NAC OUT - '' �� i.i 'II 1' II Cor:S I:lCorSli rz: - ;;',CorS!I 4.7K 'i r-- j -3 NAC OUT -3 © NAC OUT -1 t - .11 '_ - il ^ 120VAC - I FR SOURCE 1 II i -I 1 IiI ic.., s.�l w..--- -e; i iiC°i. f ---- - ,i' 1 ti.. I =-r.- i Y 9'i'i Y ;_ ig Y -Ei t j f I - ,i ii i. I'� _ HORN -STROBE MOUNTING PLATE HORN -STROBE MOUTIN PLATE HORN-STROBEMOUNTINGPLATEs ADVANCE SPEAKER STROBE MOUNTTNG PLATE sum \ (nu" 0SPECTRALERT 1 $ S ,. �r :7F R S ) _ --_} NAC OUTPUT #4 = _ ` :$ ! �1 e ' `; _ �� i :J a sp`a� irr OB21OLP Y� ti' M.UCR' SLC OUT L iL ! ..,.., -,_t---r' `� , y SLC IN �/� ! ` '"s' Z /ice �\ I H , y DETECTOR lam,:, CCCC1 1:11•, - u _ __ �� ` -0P CIES sR s-. 1 1 '----- 7 1 i o.L ,' .-1�5f--1 ' I f w l 4 f I :E_===____ `� -t {;�- & �.I - -.J , :`` ,= -ter ' . 1 i ;� / I I. I I �\ --� ---� � � �h DcTE�T�R FFA S -- . *-!•:------i j °'''" II t EA'' NOW Fa -1 ON Prrov®m STK-On U U SYNC IN a 4 NAC OUTPUT #1 �I s r"s! i \ ! , y,e�. =''��/ j i II i" ° - NAC POWER SUPPLY CONTROL & OUTPUTS form FCPS24-S? NAC POWER SUPP.Y & MOUNTNG ISOMETRICS SYNC OUT B210LP DETECTOR BASE wi RA100Z REMOTE ALARM NDICATOR BACKBOX & MOUNTED ISOMETRICS FCPS24-Sx SERIES NAC POWER SUPPLY- WIRED FOR GENERAL ALARM OPERATION0 ()STROBE QBACKBOX ADVANCE COMBINATION HORN -STROBE via FCPS NAC POWER SUPPLY )SCALE: B D B210LP DETECTOR BASE w/ & w/o THE RA100Z REMOTE INDICATOR & BACKBOX MOUNTING ISOMETRICSSPECTRALERT C NONE LAST MODIFIED ON: OCT 01 2015 FILENAME: FA-DTL1.7.1 REVISION: r0 SCALE: NONE LAST MODIFIED ON: OCT Ot 2015 FILENAME: FA-DTL1.6.1 REVISION: 10 ()SCALE: NONE LAST MODIFIED ON FILENAME REVISION OCT 01 2015 FA-DT1_1.4.1 h0 PSI /'UJ 1-i 2019 w� 3 I tr- Att i 8xz--1 ! ec $.,34/2-, WHEN PRINTED ON ARCH -D (24x36) , ,n M ,LJ ,t9 ' NNNN ENGINEER OF RECORD: SCALE: DEVELOPMENT RELEASE DATE: 0811412019 FIRE ALARM SYSTEM PROJECT INFO & CALCS FAO.00 7L cc/ s ,,s/h� © COPYRIGHT REDHAWK FIRE & SECURITY SEATTLE: ALL RIGHTS RESERVED. First Floor Layout.dwg czn (3) con w 0 0 4CHR STOR "g5 all CI) 0 rn CNJ 1 rn rn rn DRY STOR 106 RECEIVING 108 V o CUST KITCHEN 107 111 -J LL c-) PLOT DATE: 14—Aug-2019 STORAGE IFCPS8IAPS-1 AREA OF WORK a a BE 1- EXTEND NAC TRIGGER & AC POWER FROM EXISTING FACP. 2- EXISTING HORN/STROBES IN BUILDING DO NOT SYNC, 3- PHASE 2 WILL ADD ADDITIONAL HORN/STROBE AND DETECTION IN NEV PORTABLE BUILDING EXTENSION 4- PHASE 3 WILL REPLACE ALL BUILDING HORN/STROBES WITH NEW HORN/STROBES THAT WILL THEN BE SYNC'D. - SEPARATE PERMIT 1 TO r_;u ECHANICAL RM 1 G.SA/ 114 FIRST FLOOR MECHANICAL ROOM 114 1 SCALE: 1/8" = 11-01, SCALE: 1/8" = 1'-0" CUST WORK 115 KINDERGARTEN I KINDERGARTEN 168 i 166 i AK TOILET C 168A FROM APS -1 MECH RM 114' TOILET 166A AM Y CA� 1 CL' 0 0 0 8 C>- C,D MODULAR CLASSROOM 182 C,D 6 ` HN2 -4 (-• 2C,2 c- - C,D MODULAR CLASSROOM 181 DEVICE ADDRESS ASSIGNED BY TECHNICIAN (TYPICAL) 6- C,D 1 N2-41 4.7K MIMI. MP ;1:1 N2-4 N2-4 CORRIDOR 167 CLASSROOM CLASSROOM 161 1162 AL J F M''DCA_ SMOKE DETECTOR GIRLS 163 rAM. TEMP INSTALL CKT N2-4 EOL HERE THEN RELOCATE TO FINAL EOL POSITION FOR MODULAR EXPANSION OF PHASE 2. I a STAIR 165 FIRST FLOOR AREA B FIRE ALARM LAYOUT BOYS PHASE 2 MODULAR BUILDING IT IS UNKNOWN TO REDHAWK IF THIS BUILDING HAS AN AUTOMATIC SPRINKLER SYSTEM. THERE IS NO ATTIC SPACE K. 5 K 6 ORIGINAL BUILDING REDHAWK F&S DOES NOT HAVE LOCATIONS OF ANY OF THE EXISTING DETECTION, MONITORING, CONTROL OR A/V DEVICES. EXISTING HORN/STROBES DO NOT SYNC AND WILL BE UPGRADED ON A SEPARATE PERMIT SUBMITTAL. 16 WHEN PRINTED ON ARCH -D (24x36) s SCALE: e" =1'-0" 8 6 4 2 0 G a �sm rn rn sssm sd ,� rAw �� o o o N OiSLy/WW'�fav oe 5.v,Fn�a`r� 5 FCW 1 sas�f1E S s 00 •^]Y � NNNN rz O ."= Z 6. • 0 ,, JU =46W a `^- CEpp 2ZCJ CCO i G 6 V ¢ IV SCALE: 1/8" =1%0" DEVELOPMENT RELEASE DATE 0811412019 FIRE ALARM SYSTEM AREA B EXPANSION FAIOl nay 21312 30TH DRIVE SE, BOTHELL, WA. 98021 P: 425486-2600 F: 425486,2611 WA LICENSE #- REDHAHF882NH WA UBI: 602685-851 Iii 4415 SOUTH 150TH STREET, TUI WILA WA 98188 FIRE ALARM EXPANTION ISSUE DATE BY DESCRIPTION oQ 08/14/2019 BV 100% DESIGN DOCS — PERMIT SUBMBTAL SET SCALE: 1/8" =1%0" DEVELOPMENT RELEASE DATE 0811412019 FIRE ALARM SYSTEM AREA B EXPANSION FAIOl ACE 0 Without Comments p As Noted in Red g Per The Attached Letter These plans have been reviewed by The Tukwila Fire r'rev'enton Bureau for rIonformance with current City �; arils. ACC -:tan:_ is.sub eCtt to errors and 0 oftze vjolationS o1 adopted .Ii1:,SlOtis which -,G `'G�-w''Ll: . . 1.andarcis and o,'d n ^;:,-- The res1�lonsibii ty for . d gUaN, of des•c r riatotally v I ii+ the designer. 1nler. r `ti o deletions : evlsiorS to tnese drawings - this Cate will void t':' ept ce and ti'.;ii r_ c, ;r y: resubnitrz i Final accepta f ^ �1 -✓ f'_ 1' xO 4ee6 and inspect o i U i %,.r� 1. >�li The Tukwila Fire Date: 7-), (o - AG O II Fire Permit Number To-; .)--3 cal 206-575-4407 • o0 ' 0 • Q0 00• • °QOa Fire Protection VEZU[rjLE01EFl114LQ mil o g - TOILET O to X159 W Response Orifice Finish Temperature %r r-- . v..�, �' 6 o Pendent o ,o '/" ,AG AG AG I STAIR LOBBY 178 STAIR VOLUNTEER -4176 AP -169 NIC- SPRINKLER WORK TO BE PREFORMED BY OTHERS- HYDRAULIC THERS- HYDRAULIC CALCULATIONS PROVIDED BY OTHERS 0:4443 Far4 74-1(1,14F"" 4Z01441 .141-ir 4: 84° NiAd:/"KTLOEERX:F:TNJOE9,4 Arrollfrie4 Arr(41 riffil 1wiz, ' metraflex fireloop w/ 4" of movement NSELI STAIR Uwe TIE INTO EXIST NG SPRINKLER SYSTEM 7 3" GRV TEE - i 1 SIN. y SPEECH THERAPY ri i-154 0 ' TOILET Symbol - TOILET 158 K -Factor X159 Size Response a Sprinkler Legend Symbol SIN Quantity K -Factor Type Size Response Orifice Finish Temperature Note r-- . v..�, �' 6 5.6 Pendent % Standard '/" Chrome 155°F IT tVK102 VK100 2 5.6 Upright '/ Standard 1,/ Brass 155°F Total = 8 OVERHEAD PIPING PLAN SCALE: 1/8' NEW WET SPRINKLER PIPE EXISTING WET SPRINKLER PIPE EXISTING SPRINKLER HEADS HANGER HEAT TRACE (BY OTHERS) * AREA OF WORK SCOPE OF WORK 1. PROVIDE NEW 3' SCHEDULE 40 HEAT TRACED (PERFORMED BY OTHERS) PIPE TO TIE THE PRE -DESIGNED FIRE SPRINKLER SYSTEM IN NEW PORTABLE UNIT TO THE EXISTING 3' WET MAIN. 2. PROVIDE NEW METRAFLEX FIRE LOOPS w/ 4' OF MOVEMENT BETWEEN THE PORTABLE UNIT PIPING AND NEW 2' CONNECTION PIPING. 3. MAX HEAD SPACING 1 30 SQ FT FOR ORDINARY HAZARD SPACES. GENERAL NOTES 1 . ALL DESIGN AND INSTALLATION IS IN ACCORDANCE WITH NFPA 1 3, 2019. 2. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND FM LISTED 3. BLACK SCHEDULE 40 FDR ALL SPRINKLER PIPE UNDER S'. 4. 1' THREADED PIPE AND FITTINGS AND 1 -1 /4'-6' GROOVED PIPE AND FITTINGS. 5. PIPING DIMENSIONS ARE CUT LENGTH. 6. HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA 13 2019. 7. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA 13 2019. 8. OWNER TO PROVIDE ADEQUATE HEAT TD PREVENT PIPE FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM THAT IS NOT PROTECTED BY HEAT TRACE. BEAM 1 JOIST FIG. 828 1' SCH. 41 FIG. 980 SW/VEL 40 PIPE I iC " FRISLART. aAG. NW TO "I" BEAM LONGITUDINAL FIG. 828 FIG 980 SWIVEL 1" SCH. 40 PIPE BAR JOIST I co FROM VERT. FIG 1000 / 1001 FAST CLAMP LATERAL BRACE TO "1" BEAM I T 7 .: &�_ r-- . v..�, �' Viiq IT t r 11Mai GI� _ 1 'a- r r 5 i_ ira _ mesa �,-----.47 Alple -T - - .,-, N� ii,r , Ih i P�ti'i RanN ir_ I I ��� , ,Et1EYP F N! R�.Tt 1A e l Tf=l IN � .\i..IEs i Es.�- T =i k CAN IN/ - I ilig lii i E is- IIS - tI Irr.lr Te MIME L - 'ZTSS•L .8! L - = _— R BRACE TO STRUCTURE MANGER TO STRUCTURE FLEX COUP. 3/8 ATR SUPPORT LOOP HANGER AND BRACE REQUIRED ON BOTH SIDE OF METRAFLEX DRAIN PLUO METRA FLEX SEISMIC LOOP (E) BRANCHLINE ?XD -"DROP PER NFPA 13 - 9 23.5 2 WHERE THE MAXIMUM STATIC OR FLOWING PRESSURE EXCEEDS 180 PS. THE CUMULATIVE HORIZONTAL LENGTH OF AN UNSUPPORTED ARIA -OVER TO A SPRINKLER OR SPRINKLER DROP SHALL NOT EXCEED 12. FOR STEEL PIPE rL 11' RMTH VAROVER IES LENDRP GTHOVARIES - ir@.I�1/ 483' VICFLEXASSEMBLY ACT/GYP BRACKET CEILING T1LES RECESSED PENDENT SPRINKLER VICFLEX DETAIL VICINITY MAP ■ rl O v O U ti..i C o OC CO OC -C OCC' 000 N 4 a 0 0. B w Ia0 J 0 Z 4 z D W F 0 Q a 4 a 4 F N J 4 0 iz a 4 2 W U; 2> U11-1112 W Qn-1 OZ Z0rx 1-00 Z1 -a 4-0 o <U U fY� wa W T. a W F �Un ao WJai ; ac3 �j 3 WW 1- IA "'W> g Zrhi • PL -I SI I REVIEIDN/8: REV 1 1 W F H 0 z_ a 0 1,, 219PE c%J 1 i��?1Si (� �I i DATE : 7-5-19 2 1 0 4 SCALE - 1/8 = 1-O' SCALE : 1/8' = 11-0 DRAWN BY :N RODEWALD JOB NO.: SHEET NO. 25556647 FP 0.00