Loading...
HomeMy WebLinkAboutPP - 5821 S 152ND ST - LADERA HEATHERWOOD APARTMENTS - PERMITS AND PLANS5821 S 152ND ST ASSOCIATED PERMITS 09-S-020 08-F-438 889-182 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Fire Department Review Fire Alarm Review 0 FILE Gary L. VanDusen, Mayor October 26, 1989 Re: Heatherwood Apartments Rec Center - 5851 South 152nd Street, Tukwila, Wa. Dear sir: 1. The fire alarm system plans affixed hereto have been reviewed and accepted as meeting or exceeding minimum requirements of the City of Tukwila Fire Department, Bureau of Fire Prevention, with the following notes: 2. If there is an attic space in this building, detectors shall be placed in this area. 3. Remote indicator lights are required on all above ceiling smoke detectors. (UFC 10.301) 4. Audible signal devices shall be installed to indicate a fire alarm condition. They shall be so located that their operation will be heard clearly, regardless of the maximum noise level. (NFPA 72A, 2-5.4) (UFC 10.301) Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd HEATHERWOOD APTS. 5861 S. 152"6 St., 101 TUKWILA, WA 98188 PH. 206-248-3926 QAA,,,,,1/44-4\i‘k 6 Z.) p ic..___ C c,- v 0 0(7 -----1„4. b r c) ic,,,, t, --4,,,A, .4, ....,,,,,__O f7,J- ik._ s ba_ c.L._ 0 vi r\t ii-rAAA 1 -c'-Clo z- G , Cpv- __-(.1._) --frvx-v-- Norita Deckard From: William Rodal Sent: Sunday, February 19, 2017 6:45 PM To: Fire Marshal Subject: Fire Watch Attachments: CCF02192017_00000 jpg Fire Watch for 1700826 Ladera. Sprinkler activation from a BBQ no fire and no extension. Sprinkler system shut down. Alarm repair company called prior to our arrival. C .e. Masi Engine 52 8 shift Tukwila Fire Department 444 Andover Park E. Tukwila, WA 98188 206-575-4404 (Work) 206-849-0744 (Cell) William. Rodal @TukwilaWA. aov T,Za Cir, of DP/°etario, t,Fa amtmu4 e1 a fau 1 9 City of Tukwila Fire Department FIRE WATCH REQUIRED Due to the inoperative fire protection system(s) in your facility, you are required to provide a fire watch per City of Tukwila Ordinance #2437, section 16.40.120-D and Ordinance #2436, section 16.42.100-C (see reverse side). The fire watch shall be maintained until the system(s) are operational as determined by the Tukwila Fire Marshal's Office. FAX paperwork to 206-575-4439 to verify the completion of repair work and/or the restoration of system monitoring, in order to end the fire watch. The fire watch is required 24 hours a day. Designated employees may serve as the fire watch during business hours, while performing their regular job. Fire watch personnel must be aware of, and accept the duties of the fire watch. After hours fire watch personnel must be on location and must patrol the building following the close of business. Every two hours they must call 206-971-8737 and leave a message stating the following: 1. Your name. 2. Street address of firewatch location. 3. Time of day. 4. If everything is OK, state all clear. If you discover an emergency during your patrol , call 9-1-1 immediately to report it. Date: 0,12.1/(r Inspectors: 4 Start time: 2� Reason For Fire watch: gp,2,t.A.eik...., ySE M- cVs Incident #: Business Name: D E P.404C11-ked—A..000 Business Address: g41 t5& LA Lox Business Phone'—o6 ' (-i? —561 25 Person in Charge: ''(,vl wkieAr › Signature , W — Fire Marshal's Office Y — Owner/Mana er Rev. 7/29/14 T.F.D. Form F.P. 41 Tukwila Fire Marshal's Office • Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshal@tukwilawa.gov City of Tukwila Fire Department FIRE WATCH REQUIRED Due to the inoperative fire protection system(s) in your facility, you are required to provide a fire watch per City of Tukwila Ordinance #2437, section 16.40.120-D and Ordinance #2436, section 16.42.100-C (see reverse side). The fire watch shall be maintained until the system(s) are operational as determined by the Tukwila Fire Marshal's Office. FAX paperwork to 206-575-4439 to verify the completion of repair work and/or the restoration of system monitoring, in order to end the fire watch. The fire watch is required 24 hours a day. Designated employees may serve as the fire watch during business hours, while performing their regular job. Fire watch personnel must be aware of, and accept the duties of the fire watch. After hours fire watch personnel must be on location and must patrol the building following the close of business. Every two hours they must call 206-971-8737 and leave a message stating the following: 1. Your name. 2. Street address of firewatch location. 3. Time of day. 4. If everything is OK, state all clear. If you discover an emergency during your patrol , call 9-1-1 immediately to report it. Date: c9 t / `7 Inspectors: tt t3 }�d� J Start time: (73 5 Reason For Fire watch: "i31(-- 014 cra Incident #: 17 `4804 Qit.A. cx -61, 6, . Business Name: L QS P.G \-\04-‘9.f 0 > Business Address: Business Phone: L5 . ct3 (^ i 5(Q,c Person in Charge: IA_ W — Fire Marshal's Office Y — Owner/Mana Rev. 7/29/14 T.F.D. Form F.P. 41 Tukwila Fire Marshal's Office • Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshallafukwilawa.gor d—/9-/1 Vitt Ir.s �sf2rkt`fie 4 -ere •M Due to the inoperative fire protection system(s) in your facility, you are required to provide a fire watch per City of Tukwila Ordinance #2437, section 16.40.120-D and Ordinance #2436, section 16.42.100-C (see reverse side). The fire watch shall be maintained until the system(s) are operational as determined by the Tukwila Fire Marshal's Office. FAX paperwork to 206.575.4439 to verify the completion of repair work and/or the restoration of system monitoring, I order to end the fire watch. The fire watch is required 24 hours a day. Designated employees may serve as the fire watch during business hours, while performing their regular job. Fire watch personnel must be aware of, and accept the duties of the fire watch. After hours fire watch personnel must be on location and must patrol the building following the close of business_ Every two hours they must call 206-971-8737 and leave a message stating the following: 1. Your name. 2. Street address of firewatch location. 3. Time of day. • 4. If everything is OK, state. allclear. If you discover an emergency during your patrol , call 9-1-1 immediately to report it. Date:2 • f 9 Date:(2-i % 7 ' / � Inspectors: �r� � lv� - f. ;r� .` Start time: / 6 o • ' Reason For Fire watch: -gt (-•-••• di .f -s - incident #: (Business Name: (IIA ;� ' r r7 fBusiness Address: 5 814 l r/ . C an., J ,...5,.e.4.!211,4 F 1 Business Phone: ZO(p 2-'t- 3" a Person in Charge:--- .----::: ' Signature: W — Fire Marshars' ice- • Y — Owner/Manager /</trifi 4/61 Rev. 7/29/14 T.F.D. Form F.P. 41 Tukwila Fin Marshal'.% Office a Phone_ 206-57.5.4407 • Fax: 206475-4439 • Email: FireMarsh kwilawa gov King County KING COUNTY ZOO IRE WATCH FORM FIRE WATCH INSTRUCTIONS 1. 2. 3. 4. 5. 6. Do not reset the alarm if alarm cause is likely a system malfunction. Silence alarm if needed and direct the responsible party to request a service call. Fill out all portions of the Agency Copy. On the Site Copy; a. Fill out the incident number and b. Identify the fire watch frequency c. Circle the appropriate follow-up agency d. Identify which system is out -of -service. Leave the Site copy with the responsible party. tt'' Identify the person this form was left with. k J ov6 lk 'S ij 7. If the Fire Watch was declined, identify the name of the individual who declined the fire watch. 8. Was the building secure when you left? were taken. es 0 No If not, please explain what actions 9. Post placard if unable to contact a responsible party and/or when notification to building occupants is important. Fire watch placard posted? Y / N 10. Scan and Email the Agency Copy to the appropriate Fire Marshal's Office. 1.1. Include Agency Copy with your fire incident report. INCIDENT #: i' O 1(O ggj / REASON FOR FIRE WATCH: ge_e? - l / SPIN NI -C. ° '5y4TTM4 SYSTEM OUT OF SERVICE: Sprinkler 0 Fire Alarm 0 Monitoring 0 Other Suppression ❑ Other RESPONDING UNIT/COMPANY OFFICER: 3571 C ' 05 BUSINESS NAME: /.41/406474. WA'R-iee404' AfT5 BUSINESS ADDRESS: 5-gli 1, eregeam S 152-4112 Gi"r BUSINESS PHONE:4 A 0d 3V - BUSINESS CONTACT AND PHONE NUMBER: CONTACT NAME/SIGNATURE: Agency Copy - White Site Copy - Yellow Oh Zit 1 Z3FM004A 01/2019 King County • Burien/Normandy Park/KCFD#2 FMO(a,BurienFire.org, Phone: 206-209-4119 Enumclaw Fire Department/KCFD#28 FireMarshal@Enumclawfire.org King County Fire Marshal's Office FireMarshal@,KingCounty.gov Mountain View Fire & Rescue/KCFD#44 PkramlichAKCFD44.org, Phone: 253-735-0284, 253-569-4211 Port of Seattle Fire(a,PortSeattle.org Puget Sound Regional Fire Authority FirePrevention(a,PugetSoundFire.org, Phone: 253-856-4444 Renton Regional Fire Authority FireMarshal@RentonRFA.org South King Fire & Rescue Prevention.Division@,SouthKingFire.org, Phone: 253-946-7348 Skyway/KCFD#20 Admin@KCFD20.org, Phone: 206-772-1430 Tukwila Fire Department FireMarshal@TukwilaWA.gov Valley Regional Fire Authority Fire.MarshalAVRFA.org, Phone: 253-261-3616 Vashon Island Fire & Rescue Administration@vifr.org, Phone: 206-463-2405 Z3FM002 01/18 KING COUNTY ZONE 3 FIRE WATCH FORM INCIDEvT# I(10 11(065 Fire protection system maintenance and Operation is the responsibility of the property owner or manager. Implementation of the fire watch and system repairs is the responsibility of the owner. Due to the inoperative lire protection system(s) in your facility, you are required to provide a Fire Watch. King County aa'1'4v jet Email paperwork to verify the completion of repair work and/or the restoration of system monitoring. The Fire Watch shall he maintained until the system(s) are operational as determined by the Fire Prevention Bureau. The I -ire Watch is required 24 hours a day. Designated employees may serve as the Fire Watch during business hours and while performing their regular job. Fire Watch personnel must be aware of, and accept, the duties of the Fire Watch. After hours Fire Watch personnel must be on location and must patrol the building following the close of business. At the interval checked below they must record the results. ❑ 30 minutes -occupied structure Other Z ttakr5 SYSTEM OUT OF SERVICE: ❑ Sprinkler 0 Fire Alarm 0 Monitoring 0 Other Suppression 0 Other TIME AREA(S) TOURED & CHECKED CONDITIONS FOUND FIRE WAT. ,,�' INITIALS 2 .. ap --)0Q i Ic`l'1A 'Soo d -3-5 ,_.4777,,,,i C.-- 10Q; \ <VA/ () le/64 60 (f_,t, i , Agency Com Wh.ft site (upy . Yelluw 1 F%PHIS 91 '"l", 03/25/2009 WED 10:06 FAX 2063227214 CONFIDENTIAL A WASHtNGTCINA Heatherwood Apartments FIRE ALARM SYSTEMS BATTERY CALCULATION CHART B C DE F 2002/002 Form: 1/22/01 G 11111116. �� RM DEVICE/ MODULE MODEL NUMBER QUANTITY OF DEVICE! MODULE STANDBY CURRENT (AMPS) TOTAL STANDBY CURRENT (CxD) ALARM CURRENT (AMPS) 0.00055 491,*; 0,4ii:�..0 : . A CONTROL PANEL AND MODULES 0 0 Radionics Fire Control Panel 9412G 1 0.2 0.2 0.5 0.5 Radionics Annunciator 1256 1 0.104 0.104 0.206 0.206 Radionics POPIT Module 9127 16 0.0008 0.0128 0.0008 0.0128 Battery 12 VOLTS NP7-12 0 0 0 0 0 0 0 0 0 0 0 0 0 INITIATING DEVICES Smoke Detector 1 0.00055 0.00055 0.00055 0.00055 Manual Pull Stations 1 0.00055 0.00055 0.00055 0.00055 Heat Detector 5 0.00055 0.00275 0.00055 0.00275 0 0 0 0 0 0 0 0 NOTIFICATION APPLIANCES Horn ;�_i ;i42!i,r-'F ? 'Fr'°un`.'3,':::gc''E1 0 Strobe Horn/Strobe Combination Bell 2 1 0 Sum Column For Standby Load (Amps) Multiply By Required Standby Time (24 or 60 Hours) Total Standby AH 0.321 24 7.696 (G) 0.142 0.212 0.111 Sum Column For Alarm Load (Amps) Multiply By Required Alarm Time (5 min = .083) Total Alarm AH 0.284 0.212 0 0 0 0 0 1.219 0.083 0.101 TOTAL TOTAL REQUIRED SAFETY TOTAL TOTAL STANDBY ALARM AH AH (G+H) FACTOR SYSTEM SYSTEM AH (G) (H) (Multiply) AMPERE- AMPERE - HOURS HOURS REQUIRED PROVIDED 7.696 0.10114795 7.797 I 1.3 10.136 I 14AH (H) SCOPE OF WORK Heatherwood Apartments 5851 S 152nd St Tukwila, WA 98168 Tenant Improvement for the cabana and connection of the street PIV and OS&Y in the pit outside building E per the Tukwila fire department. 1. Replace the existing fire control panel 2. Replacement of one existing annunciator 3. One manual pull station (existing) 4. Five heat detectors (existing) 5. One smoke detector (to be installed) 6. Addition of two strobes 7. Addition of one horn strobe 8. Connection of two new contractor installed and maintained sprinkler tamper switches to the fire control panel The new fire control panel will become fully addressable. All existing fire devices will be made addressable to become compatible with the new fire control panel. The wire sizes are 16 AWG 4 for the notification circuits. The notification circuit is approximately 30' The exterior bell on each building is triggered by relays so only the building in alarm is tripped and made audible. Attached map shows location of exterior bells on each building and sprinkler rooms on site. Washington Alarm will provide the following: Runner service, annual inspections, maintenance and monitoring REL ANCE FIRE PROTECTION January 21, 2009 Tukwila Fire Department 444 Andover pk East Tukwila, WA 98188 Project: Heatherwood Apartments Tukwila, WA Attention: Don Tomaso RE: OTC permit for Heatherwood Apartments 8168 304"' Ave SE, PO Box 428 Preston, WA 98050-0428 Phone: (206) 682-6636 Fax: (206) 682-6744 WA Contractors License RELIAFP102L1 www.teliancefire.com FILE COPY Dear Don, Reliance Fire Protection Inc. has been contracted to remove and replace pendent sprinkler heads That has been painted at the Heatherwood Apartment complex in Tukwila. Per our phone conversation, we are required to get an over the counter permit to track this work and to get a shutdown number from Tukwila Fire. I also understand that we will be required to perform a hydrostatic test on the systems that we replace the heads in. Please note that Reliance Fire Protection Inc. is installing the same head as the one that is being Removed. If you have any questions please contact me at (206) 682-6636. Sincerely Keith Millard Project Manager ',7;75-4,407 ,0q -S--02,0 end exact address for shut' town or restoration approval, ' P 1ukWiia Fire .74/.- v2 4. /7.9" w.ad. Vie �tai1�� A� FILE MAY20 68'SI S. • IS-218� 20 itaWi W I�� it MAW & GE O = beef de+tdve CG) 04 y cifG horn 0) 0 = manual pull (l) Q • illi Ra1Wailes *tut ojikA TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job No. £sir%/ and exu.,. address for shut- down or restoration approval. 2650 1/2,g0u.lD-r /6 d rowhy by WaSitattottardit A641% I ,,�li[OrAf0 — ❑ WITHOUT COMMENTS. ❑ AS NOTED IN RED g PER THE ATTACHED LETTER C i!.aJ�iLi Ovf D iN ! 19313 The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Deet. AdJiticns, deletions or re Jisiens dr?win s aif•�r this date will v3i.i and will require 3 re i a �;,':i iI of r, rised ?; avuings. Fin,? i .; ; ,i e.;entati re of this dc,:. DAL.: /6/20-c,, BY: CI OF TJKWiLA 5.75-4407 [1-1 oci 1 ry 1gs9 .1j\, ___ -I Scale is 1/8" Toilet HD Kitchen Fire Alarm Symbol Legend FACP FAAP ,o\ 8 FIRE ALARM CONTROL PANEL ANNUNCATOR PANEL HEAT DETECTOR HORN/STROBE SMOKE DETECTOR MANUAL PULL TAMPER SWITCH STROBE SPRINKLER FLOW SWITCH GENERAL NOTES: 1. ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. 2. WIRING METHOD 15 TO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND BELOW SEVEN FEET -THEN IT IS TO BE IN CONDUIT. 3. ALL JUNCTION BOXES, COVERS AND BACK BOXES ARE TO BE PAINTED RED. 4. PULL STATIONS ARE TO BE MOUNTS AT 48" TO 53" ABOVE THE FLOOR. 5. ALL INDOOR HORNS, STROBES, HORN STROBES AND MINI HORN STROBES ARE TO BE r N , CEILING, I MOUNTED 8C,'. ABOVE THE FLOOR OR �" BELOW THE ILI�dG, WHICHEVER IS LOWER. FACP FAAP 6. SMOKE DETECTORS SHALL BE INSTALLED iN ACCORDANCE WITH THE FOLLOWING: A) 36" AWAY FROM ANY AIR HANDLING SYSTEM DIFFUSER B) NOT IN CLOSE PROXIMITY TO ANY FLUORESCENT LIGHT FIXTURES 7. EXTERIOR HORN/STROBE SHALL BE MOUNTED ON THE TOP 33 OF THE OUTSIDE WALL OF THE HIGH AS POSSIBLE FOR MAXIMUM VISIBILITY FROM THE FIRE DEPARTMENT ACCESS ROADWAY. AY. 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE OF FLAME AND HOT A5� S. 9. SPACE HAS DROPPED CEILING AT 10'0". HALF WALLS EXTEND TO 8'6". BUILDING, AS A Wire Legend Type D DESCRPTOv A 16 AWG, 4 CONDUCTOR 'FPLP' JACKETED CABLE1 B 14 AV,1G, 2 CONDUCTOR 'FPL ^' JACKETED CABLE1 C 18 AWG, 4 CONDUCTOR 'FPLP' JACKETED CABLE1 GENERAL NOTES: 1. ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. 2. WIRING METHOD 15 TO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND BELOW SEVEN FEET -THEN IT IS TO BE IN CONDUIT. 3. ALL JUNCTION BOXES, COVERS AND BACK BOXES ARE TO BE PAINTED RED. 4. PULL STATIONS ARE TO BE MOUNTS AT 48" TO 53" ABOVE THE FLOOR. 5. ALL INDOOR HORNS, STROBES, HORN STROBES AND MINI HORN STROBES ARE TO BE r N , CEILING, I MOUNTED 8C,'. ABOVE THE FLOOR OR �" BELOW THE ILI�dG, WHICHEVER IS LOWER. FACP FAAP 6. SMOKE DETECTORS SHALL BE INSTALLED iN ACCORDANCE WITH THE FOLLOWING: A) 36" AWAY FROM ANY AIR HANDLING SYSTEM DIFFUSER B) NOT IN CLOSE PROXIMITY TO ANY FLUORESCENT LIGHT FIXTURES 7. EXTERIOR HORN/STROBE SHALL BE MOUNTED ON THE TOP 33 OF THE OUTSIDE WALL OF THE HIGH AS POSSIBLE FOR MAXIMUM VISIBILITY FROM THE FIRE DEPARTMENT ACCESS ROADWAY. AY. 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE OF FLAME AND HOT A5� S. 9. SPACE HAS DROPPED CEILING AT 10'0". HALF WALLS EXTEND TO 8'6". BUILDING, AS A B C D E F G CURRENT FORMULA: OHMS PER FOOT X DISTANCE/1000 X TOTAL CURRENT =VOLTAGE DROP DEVICE/ MODULE MODEL NUMBER QUANTITY OF DEVICE/ MODULE STANDBY CURRENT (AMPS) TOTAL STANDBY CURRENT (CxD) ALARM CURRENT (AMPS) = - Heatherwood Apartments STROBE .142 X 1 = .142 .120 X .566 = .07 ` 1000 TOTAL CURRENT FOR THIS CIRCUIT .566 CONTROL PANEL AND MODULES 0 0 Radionics Fire Control Panel 9412G 1 0.2 0.2 0.5 0.5 Radionics Annunciator 1256 1 0.104 0.104 0.206 0.206 Radionics POPIT Module 9127 16 0.0008 0.0128 0.0008 0.0128 Battery 12 VOLTS NP7-12 2 0 0 0 0 0 0 0 0 0 0 0 0 INITIATING DEVICES Smoke Detector 1 0.00055 0.00055 0.00055 0.00055 Manual Pull Stations 1 0.00055 0.00055 0.00055 0.00055 Heat Detector 5 0.00055 0.00275 0.00055 0.00275 0 0 0 0 0 0 0 0 NOTIFICATION APPLIANCES Horn - 0 Strobe 2 - 0.142 0.284 Horn/Strobe Combination 1 - 0.212 0.212 Bell 0 0.111 0 0 0 0 0 Sum Column For Standby Load (Amps) 0.321 Multiply By Required Standby Time (24 or 60 Hours) 24 Total Standby AH 7.696 (G) _ - - --- Sum Column For Alarm Load (Amps) 1.219 Multiply By Required Alarm Time (5 min = .083) 0.083 Total Alarm AH 0.101 (H) TOTAL STANDBY AH (G) TOTAL ALARM AH (H) REQUIRED AH (G+H) SAFETY FACTOR (Multiply) TOTAL SYSTEM AMPERE- HOURS REQUIRED TOTAL SYSTEM AMPERE - HOURS PROVIDED 7.696 0.101148 7.797 1.3 10.136 24AH NOTICE IMPORTANT N ilCt Because of increased demand our inspectors' schedufes re booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minimum of 48 hours n advance of the date you want an nspection. VOLTAGE DROPS FOR CIRCUIT DEVICE CURRENT # OF DEVICES CURRENT FORMULA: OHMS PER FOOT X DISTANCE/1000 X TOTAL CURRENT =VOLTAGE DROP FACP CIRCUIT HORN -STROBE .212 X 2 = .424 (4.016 x 30 )_ VDC STROBE .142 X 1 = .142 .120 X .566 = .07 ` 1000 TOTAL CURRENT FOR THIS CIRCUIT .566 WASHINGT❑N ALARM, INC, A completed, signed, Tu';<wiil Fire -Department Pre-test Certificate imust be presented to the Inspector prior to comrrercernent of Acceptance Testing cif any Fire Alarm and Detection Systems. Failure cif test will result in a Re -inspection Fee and termination of the testing. IUKw1LA FIRE DEPARTMEAR Please call: 575-4407 and give this job No. Cd 1253 S,JACKS❑N STREET and exct address for shut' town or restoration aoorif; SEATTLE, WASHINGT❑N 98144 PHONE: 206-328-3288 FAX: 206-322-7214 CONTACT: RYAN AAL WWW,WASHINGT❑NALARM,C❑M FILE COPY HEATHERWOOD APARTMENTS -CLUBHOUSE ap U) U L Li' 00 L) C C 00 x i ACCEPTED =1 Wthout C ; nrnents As Noted n Red Per The A tact ed Letter t nese plans have been : F..� ; L The Tukwila Fire Prevention Bur: a:i `oi ccr ,.:. $s,, B;=E,u1 current city standards. Aixapta,Ice d ;and omissions which (I_. of adopted stanuaras and ordinanz..l" ; b ::: =�.r f for the adequacy of e . r . . tN m : .� -LLrf�� ;..�i� • �.Yii- � �9`�l4 3 me 'J �--s=�±ier. Additions, deletions or .4 :, 5: - j .F,ct drawings atter this date will void the.acc� will require a resubmittal of revised drawing fcr subsequent sequent approval. Final acceptance is subject to Feld test and inspection b), The Tukwila Fire Prevention Bireau. Date: 0 -0)-6 By: U PAID AUG 21 20000A' 'TukwFire ct,t DATE: August 19th, 2008 DRAWN BY: M. McILWAIN