HomeMy WebLinkAboutPP - 5950 SOUTHCENTER BLVD - SOUTHCENTER STORAGE - PERMITS AND PLANS5950 SOUTHCENTER BLVD ASSOCIATED PERMITS 18-F-061 D01-026 02-F-052 02-S-034 4 iltiq) ZIT SITE LOCATION I1 yz,Z-I CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 3597000202 Site Address: 5950 Southcenter Blvd Tukwila, WA 98188 Suite Number: Floor: Main Tenant Name: Tukwila Self Storage New Tenant? 1:1- Yes - No Property Owner's Name: Azose Commercial Mailing Address: 8451 SE 68th St, #200 Mercer Island, WA 98040 CONTACT PERSON -if there are questions about the submittal. Name: Manny Ornelas Day Telephone: 206-436-5301 Company Name: Washington Alarm Mailing Address: 2030 Airport Way S City State Zip ermits@washin tonalarm.com City State Zip E-mail Address: p g Fax Number: 206-322-7214 Contractor's City of Tukwila Business License number: BUS -0992857 Total number of new/relocated devices or sprinkler heads: (2) Valuation of Project (contractor's bid price): $ 1 ,100 Scope of Work (please provide detailed information): Installation of of an AES radio to replace existing phone lines, also adding pull station next to FACP. Connected to existing 5820XL PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWAGENT: Signature: Date: 3/28/2018 Print Name: Manny Ornelas Day Telephone: 206-436-5301 Plan Permit App.doc 8/22/14 TFD FP Form 8 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /S -F-061 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:1TA4A001 ` IA Sa g4 Type of Inspection: Address: Suite #: 6 150 SC 1-k6cAll Contact Person: Special Instructions: 1;114( Phone No.: 17tApproved per applicable codes. Corrections required prior to approval. COMMENTS: /gs irtild ik-ts e-,'<i)i b Needs Shift Inspection: f\i° Sprinklers: Vfi Fire Alarm: 114° Hood & Duct: Monitor: WA' trtAtUAA Pre -Fire: Permits: Occupancy Type: Inspector: ----/___644 S3 Date: 6'%te/I g Hrs.: f -t) $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Cali to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 City of Tukwila AUG 2 7 2002 Steven M. Mullet, Mayor Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Permit No. D O ( Z 2_�/ Project Name7714.) ( 61 CiC--- Addre s s 6-)410119 I (9 IZ"! A., Retain current inspection schedule Needs shift inspection Suite # /X Approved without correction notice Approved with correction notice issued Sprinklers: XFire Alarm: Hood & Duct: Halon: Monitor: Pre -Fir Perm Author ed Signature FINALAPP.FRM Dc:3atie24C 0 2— Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 07/26/02 08:39 FAX 375+4439 TUKWILA FIRE J02 TUKWILA FIRE PREVEN'T'ION BUREAU 444 . •ever Park East, Tiilcwi a, WA 98188 - Phone 206-575-4407 - Fax 206-575-439 E-mail: tukfdprv@ci.tukwila.wa.us I 1 � r ux'. CONTRACTORS MATERIAL AND TEST CERTIFICA'. 1 • L� FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm Systom is ready for Fire Department acceptance tasting. Failure of test•wilt result in, erraimnion of tie testing and additional fees will be assessed..Contractor is.respoiasible far supplying manpower for Final Acceptance. Testwith two-way communications. Date /'7/o 3, - Permit # 0 2. - 5057, Installing Compsny AT ROYl ► GS "I G • Installing Contrz ctor's Address 4 0 5 5 • 13 RAPS Y1 D O Y1 5T . City CATTt�) WA •) q g t o g Phone # LO Co - 2- - 4 to oa Installer's Name (PRINT) '. U LA I ' 13 AK E License and/or Certificate 3A K E RSA D 44 Q A Name of Facilit i SouTH c.£Y T ,R. STORA-CSE Property Addres 5'1 50 .0 (-CT F{ CLY1TER, 61-V D. City Tukwila Zip Code cig / 8'fc- Occupied as 5E LF STO RA&E FA U U1 Owner or Repri sentative FR1E D MAV1 PE.Vl1 �OPW EXTr Phone # ZO(Q -A-4 2.- 3 to Il General Contra:tor CDVIs'f R U CT I Ofl AttP.S.4ATiejL'(r1 Y1V1l l� D D L( , Electrical Contactor M E ROI L>( (\Y1 Iitt00 b . LOA FACP Equipm•:ntManufacturer h►t.,GYlT KYII //PT Model #587..oXL- This system has been led, pre. and operates in accordance with the standards listed below and was inspected ' )y • On (date) Sl 6 /01., *. Circle all that apply:. i NFP. i 72, Chapter 12 4 5 6 7 and/or UFC STD 10-2:SBC L7.1.2,1997 ED. NFP, L 70, National Electrical Code, Article 760 Manufacturer's Instructions V Man zfacturer's Instructions Other (specify) Tukwila City Ordinance Numbers 1900, 1901 UL Central Station Monitor WAN -1111 10,To Yl ALARM System is monitored by NA/A1411"1 &TO rl ALARIA and includes the devices listed on back. e * SIGNED System Firm'vare: Insta led version a Checksum SjrK4- Date Initial pm �C�u 2 '*c -Installation Date. -- Revisions an Reasons Date rhia, Programmed by R LA 14 F. 3AKE.F?_ 07/28/02 08:39 FAX 575+4439 TUEWILA FIRE 'Tukwila Fire Prevention Bureau-. Material and Test Certificate EQUIPMENT D;STALLED AND TESTED: • Control Panel of Manual Station of Smoke Detector s of Heat Detectors of Net Detectors of A V Devices of Audio bevices of Visual Devices of Auto Door Rel. ase of Trouble Indictors of Batteries ; b i Leel i tght Psi �de-r Make/Model 6K .5-62.0%- 54'i S Make/Mode15K 5D5ooP5 Make/Model 5K 5 p 5 0 S APS Make/Model Make/Model 6\is XY1 Ge ti sor Make/Model S5 P'Z41 S '17-1-111,0k Make/Model . • Make/Model Make/Model Make/Model > • YAnP1V 12 LYt,Lo—so_) Read ngs Battery Full Toad Charge Generator of Make/Model HVAC Contrc Is _ of _ _. Make/Model Fire Alarm Dialer of Make/Model I ne t ud u'1 5820 Monitored by Annunciator WA lid lh ltTo-r _ A 14\e ,A . of Make/Model S K 58(0 0 R Sprinkle System: (Fire Alarm connections only] Water Flow Sw. �r , of 5 Make/Model V i c..:1 -A u 1, c 70 5 '4-t) Make/Model o4-10-1-- UF Make/Model fie Pc vs A Make/Model t"a tfe r— Valve Tempe: Sw. j of I_ PIV of Elec. Alarm lien l _ of _L Automatic time Delay of Water Flow Alarm 1 seconds. None Installed Do you meet audible/visible of WAC 51-44, UFC STD 10-2,1997 ED., and/or NFPA 72, 1999 edition, Chapter 6? Yes Test of slant System on emergency power, satisfactory? Yes No _ Test W itnes.;ed byct 4 Title CK F QD Comments: Date lI103 TFD FP Fona +►t 10 7 GENERAL INFORMATION 7r-741-(--r-_-,,n\\11,-.7:r 13-11 CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR UNDERGROUND PIPING T UKv„LA PUBLIC WORKS MAR 2 5 2002 PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by en owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the Job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty mzterial, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAME 5oGtr1-1Tit 0 6 PROPERTY ADDRESS ,ou7{, (.6 `/7-6 „- 610d. /1). DATE ///0/02, 558(1080) PRINTED IN USA Contractor's Material & Test Certificate for Underground Piping d (� ACCEPTED BY APPROVING AUTHORITY('S) NAMES ADDRESS PLANS iNSTALLATIOt: IF CONFORMS TO ACCEPTED Pt. ANS EQUIPMENT USED 15 APPROVED NO, STATE DEVIATIONS OYES ONO ❑YES • NO IF HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION EYES ❑NO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT NO, EXPLAIN INSTRUCTIONS HAVE COPIES OF APPROPRIATE INSTRUCTIONS AND CA47E AND MAINTENANCE CHARTS OYES 0 N BEEN LEFT ON PREMISES IF NO, EXPLAIN • LOCATION SUPPLIES °LOGS. UNDERGROUND PIPES AND JOINTS • PIPEvTYPES AND CLASS f•Ittt�Q aSS SZ TYPE JOINT �/� I fI Pigii- YI f it/til, .L1J73tj PIPE CONFORMS TO rJ GSTANDARD- ©YES • NO It YES ONO FITTINQS CONFORM TO STANDARD IF NO, EXPLAIN JOINTS NEEDING ANCHORAGE CLAMPED, STRAPPED, OR ACCORDANCE WITH ---r,„, ie,, , IASTANDARD BLOCKED IN 4%PES 0 N IF NO, EXPLAIN TEST DESCRIPTION FLUSHING. Flow the required rete until water is clear as indicated by no collection of foreign material in burlap ba9s at outlets such as L/min) for 4 -inch pipe, 600 GPM (2271 L/min) for 5 -inch pipe, for 8 -inch pipe, 1500 GPM (5678 L/min) for 10 -inch pipe and 2000 stipulated flow rates, obtain maximum available. 200 psi (13.8 bars) for two hours or 50 psi (3.4 bars) above static workmanship is satisfactory. have little or no leakage at the joints. (1.89 L/h) per 100 joints irrespective of pipe diameter. The leakage joints the installation shall be considered unsatisfactory and nec• may be increased by 1 11 oz per in. valve diameter per hour It dry barrel hydrants are tested with the main valve open, (150 mL/min) leakage is permitted for each hydrant. ydrants and blow -offs. Flush at flows not less than 400 GPM (1514 750 GPM (2839 L/min) for 6 -inch pipe,1000 GPM (3785 L/min) GPM (7570 Umin) for 12 -inch pipe. When supply cannot produce HYDROSTATIC. Hydrostatic tests shall be made at not less than pressure in excess of 150 psi (10.3 bars)for two hours. g4KAGE. New pipe laid with rubber gasketed joints shall, if the e amount of leakage at the joints shall not exceed 2 qts. per hr. shall be distributed over all Joints. If such leakage occurs at a few essary repairs made. The amount of allowable leakage specified above (30 mL/25 mm/h) for each metal seated valve isolating the test section. so the hydrants are under pressure, an additional 5 oz per minute 1.7 11PI FLUSHING�J TESTS NEW UNOERGROUNO PIPING FLUSHED ACCORDING TO N F oft ZL/ STANDARD Erc'ES ED NO BY (COMPANY) IF NO, EXPLAIN HOW W FLUSHING FLOW WAS OBTAINED PUBLIC WATER ['TANK OR RESERVOIR EDFIRE PUMP THROUGH WHAT TYPE OPENING ❑ HYDRANT BUTT. OPEN PIPE � {� LEAD-INS FLUSHED ACCORDING TO /J//' (-4 STANDARD ❑YES ❑NO IIF NO, EXPPLAIN NC; ll ("-,---s-7----jay/-,4ff SIX btCnCit:1 ..L i C- , HOW FLUSHING FLOW WAS OBTAINED PUMP THROUGH WHAT TYPE OPENING ❑ Y CONN. TO FLANGE & SPIGOT ❑ OPEN PIPE IOVERI (]PUBLIC WATER • TANK OR RESERVOIR ❑ FIRE 558(1080) PRINTED IN USA Contractor's Material & Test Certificate for Underground Piping d (� 13-12 41,01/ I I , HYDROSTATIC TEST LEAKAGE TEST SPRINKLER SYSTEMS HYDRANTS CONTROL. VALVES ALL NEWUNDERGROUND PIPING HYDROSTATICALLY TESTED AT .2/v PSI FOR HOURS TOTAL AMOUNT OF LEAKAGE MEASURED 0 GALS. HOURS ALLOWABLE LEAKAGE GALS. HOURS NUMBER INSTALLED (TYPE AND MAKE M(t WATER CONTROL VALVES LEFT WIDE OPEN IF NO, STATE REASON pi } c%5 11 7;q: is JOINTS COVERED ©YES I-1NO ALL OPERATE SATISFACTORILY p1' ES LJNO l.0%+l�t N4 G4 01)6' h[]YES i O HOSE THREADS OF FIRE DEPARTMENT CONNECTIONS AND HYDRANTS INTERCHANGEABLE WITH THOSE OF FIRE DEPARTMENT ANSWERING ALARM REMARKS DATE LEFT IN SERVICE YES ONO NAME OF INSTALLING CONTRACTOR SIGNATURES FO/ ROPERTY O —`J4 £ i FO• IN! ,_407," dir ADDITIONAL EXPLANA O �N ' OTES tucture./ne. Contractor's Material & Test Certificate for Underground Piping Chapter 2 Water Supplies 2-1* General Provisions. Every automatic sprinkler system shall have at least one automatic water supply. 2-2* Water Supply Requirements for Sprinkler Sy's tems. 2-2.1 Water Supply Requirement Tables. 2-2.1.1* Water supply requirement tables shall be used in determining the minimum water supply requirements for light, ordinary and extra hazard occupancies. Occupan- cy classification shall be determined from Section 1-7. (a) 'Table 2-2.1(A) is used to determine the minimum volume of water and pressure normally required for a pipe schedule sprinkler system. THE TABLE IS TO BE USED ONLY WITH EXPERIENCED JUDG- MENT. (b) Table 2-2.1(B) is used to determine the minimum volume of water and pressure normally required for a hydraulically designed sprinkler system. 2-2.1.2 The following shall be used in applying Table 2-2.1(B). 2-2.1.2.1 The densities 2-2.1(B) are based on standard orifice (1/2 in. sprinklers. For use of 4-1.1.3. and areas provided in Figure the use of standard response, ) and large orifice ("hz in.) other types of sprinklers see 2-2.1.2.2 The water supply requirement for sprinklers only shall be calculated from the density curves in Figure 2-2.1(B). System piping shall be calculated to satisfy a single point on the appropriate design curve. necessary to meet all points on the selected curve. 2-2.1.2.3 When inside hose stations are planned or are required by other standards, a water allowance of 50 gpm (189 L/min) for a one hose station installation [ 100 gpm (378 L/min) for a two or more station installation] shall be added to the sprinkler requirement at the point of connection to the system at the residual pressure required by the sprinkler system design. 2-2.1.2.4 Water supply demands for ceiling sprinklers and in -rack sprinklers for rack storage systems shall be combined and hydraulically balanced at the common supply point. 2-2.1.2.5 Water allowance for outside hose shall be added to the sprinkler and inside hose requirement at the connection to the city water main, or at a yard hydrant, whichever is closer to the system riser. 2-2.1.2.6 The lower duration figure is ordinarily accepta- ble where remote station water flow alarm service or equivalent is provided. 2-2.1.2.7 When pumps, gravity tanks or pressure tanks supply sprinklers only, requirements for inside and outside hose need not be considered in determining the size of such pumps or tanks. 2-2.1.2.8 The water supply requirement for sprinklers only shall be based upon the area of the sprinkler operation selected from Table 2-2.1(B) or upon the area of the largest room, at the discretion of the designer. Such a room ATRONICS, INC. ELECTRONIC SYSTEMS March 8, 2002 City of Tukwilla Fire Dept. 444 Andover Park East Tukwilla, WA 98188 Attention: Fire Marshall Dear Sir or Madam: Please find attached check, three sets of submittal documentation, and three sets of drawings for the Fire Alarm System we are proposing to install at: Southcenter Storage, 5950 Southcenter Blvd., Tukwilla 98138. The owners of this facility are Tukwilla Self Storage Partners, LLC (Attn: Steve Freidman), 85 South Washington St., #308 Seattle, WA 98104. If you have any questions, or if we can be of help in any further way, please call us at 206-762-4600. Sincerely, `/tat y21 Mary Mason Atronics TEL: 206-762-4600 0 405 SOUTH BRANDON, SEATTLE, WA 98108 • FAX: 206-762-4117 • ATRONICS, INC. ELECTRONIC SYSTEMS FIRE ALARM SCOPE OF WORK — SOUTHCENTER STORAGE (Job 1412) March 8, 2002 This is new construction, single building, 5 floors built into a sloping grade such that Basement 2 (lowest level) is completely under ground and Basement 1 (the only level with entry/exits) is partially exposed. There are 3 floors above ground for a total of 5 floors. Atronics is providing fire alarm (per Tukwilla Ordinance, Addressable System, Silent Knight 5820XL). The Head -End equipment (control panel) will be located on the uppermost of the two basement levels: B1. The headend of the Fire Alarm System (FACP and Communicator) to be located in the Electrical/Sprinkler Room that is accessed from the outside by door A3. The Fire Alarm Annunciator is to be located just outside the Office/Sales area, adjacent to the Electrical/Sprinkler Room. Keys to access the Electrical/Sprinkler Room in which FACP is located, to be in Knox Box (provided by others) mounted at the front (Office Entry) side of the building on floor B1. We recommend that the Fire Alarm system Riser be located to the West of the Westerly elevator. The Fire Alarm system riser requires (1) 3" conduit to run from B2 up to floor 3. Riser piping to be provided and installed by the electrical contractor. For the Fire Alarm System riser, electrical contractor to provide and install (1) 6X6 pull box at 6' off the finished floor on each of the five levels. Again, we request that if possible that these risers and associated boxes be placed to the west side of the most westerly of the two elevator shafts. Electrical contractor to provide and run conduit anywhere fire wire is to be run below 8' off the finished floor. Atronics to provide materials for complete and operational systems per requirements of local authority having jurisdiction. Atronics to provide and pull in Fire Alarm cable, and to trim devices, do head -end hookup, programming and test, and provide owner training on the use of the Fire Alarm system. Atronics to procure Fire Alarm Permit only. -Heat detectors for elevator shunt to be provided by electrical contractor -If there are any AHU rated at 2000 cfm or higher, the Mechanical Contractor will be required to provide and install duct detectors and the associated test/reset switch. These will need to be connected to Atronics Fire Alarm Control Panel for the purpose of Supervision, per City of Tukwilla Ordinance #1900, duct detectors to send supervisory signals only, no alarm. -Atronics is requesting copies of the drawings for elevator controls to facilitate the connection that will need to exist between them and the F.A.C.P. -Atronics is requesting drawings of the sprinkler riser as well, because again, we need to have a connection from the sprinkler devices to the F.A.C.P. TEL: 206-762-4600 • 405 SOUTH BRANDON, SEATTLE, WA 98108 • FAX: 206-762-4117 ATRONICS, INC. ELECTRONIC SYSTEMS SUBMITTAL LIST OF EQUIPMENT FIRE ALARM SYSTEM FOR SOUTHCENTER STORAGE, TUKWILLA, WASHINGTON 1 of a Silent Knight 5820XL Addressable Fire Panel 1 of a Silent Knight 5495 Power Expander Panel for the 5820XL 4 of a Yuasa NP1812 backup battery 1 of a Silent Knight 5860R Remote Annunciator 1 of a STI1200 WeatherProof Enclosure for Annunciator 1 of a Silent Knight SD500ANM Addressable Notification Module for the 5820XL 5 of a Silent Knight SD500ARM Addressable Relay Module for the 5820XL 6 of a Silent Knight SD505APS Addressable Photo -electric Smoke Detector with SD505AB Base 13 of a Silent Knight SD500PS Addressable Manual Pull Station 51 of a System Sensor P2475 Combination Hom/Strobe 1 of a System Sensor P24110K WeatherProof Hom/Strobe with WBB WeatherProof Backbox 1 Lot of Riser Rated Fire Cable, 16 Guage, 2 Conductor 1 Lot of Riser Rated Fire Cable 14 Guage, 2 Conductor TEL: 206-762-4600 • 405 SOUTH BRANDON, SEATTLE, WA 98108 • FAX: 206-762-4117 City of Tukwila �y� 0 5 r Steven M. Mullet, Mayor Fire Department Thomas P. Keefe, Fire Chief February 1, 2002 I - Mr. Barry Gooding Smith Fire Systems 1106 54th Ave East Tacoma, WA 98424 Re: Southcenter Storage, SFS Job #T2-229 Dear Mr. Gooding, In regard to the Southcenter Storage project, the Tukwila Fire Department has determined that the revised hydraulic calculations submitted on January 11, 2002, provide the sufficient fire flow required for this project. In addition, as previously discussed Hose Connections for Fire Department use, per NFPA 13 1999, section 5-15.5, shall be installed on this project. We will allow the roof manifold to be deleted due to the standing seam roof construction method employed for this project. The Hose Connections are deemed necessary by the Fire Department, due to the limited access to the interior portions of the building via exterior openings for fire suppression efforts. If you have any questions in regards to the above items please do not hesitate to contact me. Sincerely, Don Tomaso Fire Marshal cc: file Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 City of Tukwila Steven M. Mullet, Mayor Fire Department Thomas P. Keefe, Fire Chief March 18, 2002 Mr. Barry Gooding Smith Fire Systems 1106 — 54th Ave East Tacoma, WA, 98424 Reference: Southcenter Storage, SFS Job # T2-229 Dear Mr. Gooding: In regard to the Southcenter Storage Project, the Tukwila Fire Department has determined that the revised hydraulic calculations submitted on January 11, 2002, provide the sufficient fire flow required for this project. In addition, as previously discussed, hose connections for fire department use, per NFPA 13, 1999, section 5-15.5, shall be installed on this project. We will allow the roof manifold to be deleted due to the standing seam roof construction method employed for this project. The hose connections are deemed necessary by the fire department due to the limited access to the interior portions of the building, via exterior openings for fire suppression efforts. After your initial plan submittal, a second review of the project with suppression personnel for tactical considerations, indicated a need for a standpipe system. This review was done after your call to us in regard to sprinkler system requirements for this project prior to the project bid date on March 12, 2001. Sincerely, Don Tomaso Fire Marshal Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 12/20/01 THC 16:43 FAX 253 926 2350 SMITH FIRE SYSTEMS (253) 926.1880 FAX (253) 926-2350 SMITH FIRE SYSTEMS, INC. December 20, 2001 Attention: Phil Lyons 1106 54th Avenue East Tacoma, Washington 98424 Reference: Southcenter Storage SFS Job #: T2-226 Gentlemen: The following information is in response to our conversation concerning the total hose allowance provided in the hydraulic calculations and the auto ball drip that will be installed in the roof standpipe feed piping. Per NFPA #13 1996 edition section 1-4.2, definition of miscellaneous storage and the reference to section 1-4.7 which classifies this occupancy as ordinary hazard group ll, the required design density is .20 gprn over the most remote 1500 square feet. Per section 5- 2.3 the total hose allowance required is 250 gpm. The total demand for this system, not including overflow is .2 x 1500 = 300 gpm + 250 gpm total hose = 55Ogpm total system demand. Per WSRB recommendations the sprinkler system has been designed to provide .15 gpm over the most remote 5000 square feet. The total hose demand recommended is 750 gpm. The total demand for this system, not including overflow is .15 x 5000 = 750 gpm + 100 gpm for total hose allowance for a total system demand of 850 gpm. In conclusion the WSRB requirements exceed the NFPA total system demand requirements by 300 gpm so the hazard has been adequately protected per NFPA requirements. If SFS were to calculate the systems at the NFPA required density, rather than the WSRB recommended density, the calculation results with 250 gpm hose allowance would be far less hydraulically demanding than actual calculations shown with only 100 gpm added for total hose allowance. If you have any questions and/or comments, please do not hesitate to contact me. Sincerely, Barry Gooding, Design Manager SMITH FIRE SYSTEMS, INC. [�] 001 12/20/01 1111 15:44 FAX 253 926 2350 40'-0" AFF @ 3RD FLOOR SMITH FIRE SYSTEMS POTTER ROEMER MODEL # 5855 POST INDICATOR Z002 002 POTTER ROEMER MODEL # 5876 TWO-WAY OUTLET WITH (2) #4085 FIRE HOSE VALVES 4. 0-6 •er 1�0�. 1/2" AUTOMATIC BALL DRIP PIPE TO 2-1/2" CPVC DRAIN 4" MUELLER P2360-6 GATE VALVE -+— 2 1/2" FIRE HOSE VALVE W1 CAP AND CHAIN POTTER ROEMER # 4065 ROOF MANIFOLD DETAIL NTS SMITH ARE SYSTEMS, INC 1106 54TH AVENUE EAST TACOMA, WA 98424 (253) 926-1880 CONTACT: BARRY GOODING SOUTHCENTER STORAGE 5950 SO'iJTHCENTER BLVD. TUKWILA, WA SFS JOB# T2-229 U1/11/UZ F1t1 U5:35 FAA Z;1 9GtSZ350 / SMITH F 1 RE SYSTEMS SMITH FIRE 5,3TEMS, INC. 1106 54th Avenue East 9 Tacoma. Washington 98424 (253) 926-1880 ® FAX (258) 926-2350 CONTR, REG. NO. SMITHFS1360T X1002 HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME SOUTHCENTER STORAGE JOB NO. T2-229 DATE ' /11/02 ADDRESS 5950 SOUTHCENTER BLVD. BY JMCVEY TUKWILA, WASHINGTON SYSTEM DESIGNATION: WET - THIRD FLOOR, S.E. CORNER HAZARD DESCRIPTION: ORDINARY HAZARD CLASS PER NFPA 13 SPECIFIC RULING: NA RULING MADE BY: OF DENSITY: 0.20 GPM OVER THE MOST HYDRAULICALLY REMOTE 930 SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: INSIDE HOSE 250 GPM ADDED AT: BASE OF RISER OUTSIDE HOSE 250 GPM CITY CONNECTION IN -RACK SPRINKLER DEMAND N/A GPM SYSTEM TYPE: WET "C" FACTOR OVERHEAD : 120 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: SPRINKLER MANUFACTURER: RELIABLE MODEL: K -FACTOR: TOTAL NUMBER OF SPRINKLERS THIS SYSTEM "C" FACTOR UNDERGROUND : 140 100 SQUARE FEET F1FR TEMPERATURE: 155° F 5.62 ORIFICE SIZE: 1/2" 210 WATER SUPPLY: STATIC: 120 PSI RESIDUAL: 20 PSI FLOW: 1,767 GPM ELEVATION OF TEST: 72' DATE OF TEST: FEBRUARY 1999 DATA PROVIDED BY: CITY OF TUKWILA LOCATION OF TEST: BASE OF RISER DEMAND 557.29 GPM REQUIRED AT 35.96 PSI (INCLUDING 250 GPM FOR HOSE STREAMS) SUMMARY 807.29 GPM REQUIRED AT 41.19 PSI AT CONNECTION TO CITY MAIN (INCLUDING 500 GPM FOR TOTAL HOSE STREAMS) CERTIFICATE OF COMPETENCY STAMP i` - Q 01/11/02 FRI 08:36 FAX 253 926 2350 SMITH FIRE SYSTEMS ` RESSURE IN PSt 0 0 o io 4 (N jiy III 1 [_I_ I g Z 003 -a`L1 F- :7-7t-• " _=E�_ 't rt=� F= rte_; _ _ =r.--'1::71" , 1 -_s�-, ',L. —Hi- "-t- F �— z 1 1 , t L T , --r- T'..i , - _ , -ri �.— i = ``r ;t,r N.. - +Ir tea; it rril" mal i --- i •1 r+ -.-•I I 1 : ' I i +-- I � I 1 , +• "- . I »-- �. { T--1-- -moi-i f 1 I -^ _,- -' 1 . ' s . .-t r- +-F-i- - }�'-,--i-•' r--r+---�' 4+-1- r-+-�� " i T 1- I , I I I r T !--i { -t-i-+-r-'--r I - i I : st - • I ' I I , -i-'-' , , -I- 1 I I 1 �•� -4 -}--I t, 1' I I f r 1 I I I +.-+- , -+- . 'I 1 f : ; _• .'' . 1 1 I1 II 11 1 1 I 1 T _-_'-I- , 4 I -� - 1 -i F-4_- r -t- 4 t i* 1 1' 1 14 h . , t ' f 1t (' 1 T 1 1-+ ♦, 44-4-4 1 WATER SUPPY DATA t +___1_ l 4 1 I I 4, 1 '• _, -1 - _-4_-1 -4T-1-1-+-• • . 6- 1 I- `-1 - ,s_.` •+ I -4- 4 4, 4 4, i + +-� I- 1-. ' ' 1 1 i- 1 , 4 14 -'--1 L ` 1-1 --4---4-4-T i- L. ' ' I , I p e ` + -4-- 20 1767 C :-4--I 1 , _ f r -+• • ( , -4 1 I < . + - - F ' III '4-'1' , i -4,-1-!'"; --I .. _.. tom .. -I 1 t + J 1 f'--'--1 { I -1, t`!-• _ ' "7-,_''- L- .+ �--' I -+-,. rt , 1 ' I- C j r � --t , , r i + j�,{� I _••i_,_, 1 -t- +�-a f I 1 f 1 -,--?--1 I + I -4- _ } -!- l SIL ' I + J•` I I.('�, 'f-"I••t--�-f-..*_r �r`{i.�__ -+- I ; -'1f `- �'^��II 1 I { f l 1 I I { -, '''�j 1'1-2 I I 1! 1 1 -1.-+_•. 4.- 244, { I i 1 1' 1 ( t R_W1 _,--` 1 I •1 j � '' I 4- ' l l 1 1. -'•-r i -+ 1 f + 4 I I I I I I 4 4 1 1 -4 -4-4 l ` ,� . . ,_ �+ rV -6�-- � -4-71-1- -+-I-•1 _ I 1 rt. -i--'-4- ` 1 1 1-- -'1 - 1 1 -•�^.e-x : ---1 + l - , , I 1 I-- r j 1 1 ' 1 I - } t + • 4 -1 /-� , yC'Ya� 01 _4_4_4- I + 1 1 1 1 1 r ^f--•--+--•i•._...r I--' I i 1 +, + , +Iti-- - , -h- _ r rn [b µ 4 . 1 r t' - - - - -+ - st� " i*- '- 11, , tj` 4 I`'4i ;+- - }I-� {,� 1 ' 4 + ' 1-� ~ - --t ' f , 1: 1 I r• 1 t . ..1__r+-4 --1- - 1 ,-1'-r--•r-•++ ; t _• -F-} r -r -t- 5 ! f f t -4 1- - 4 -1 -+ • * 1 `;` I I f I ' i 4-- I I i --+ ,- -` r SOUTHCENTER STORAGE 5950 SOUTHCENTER BLVD TUKWILA, WA T2-229 THIRD FLOOR, SE CORNER �__!_ j 1 i - t ---a- ---r. -1 , I- + 11 1 -�'-.- r t _ 1 --'- + 1-F- •--1-- 4 1- t y i -i -4- I 1 1 M', --7 � 4 4 4 ` - . . -�.- 1 + ' 4 4" -}-F-1 .t - { I -,1.. 4 I 1 I -}~--{- L. `. + . 4 i 4 . -1'- - ,-4- �--..- -1-4 1- 1- I , 1 H-^!.-!- I-••+ I- ``� .--J�V-� f--r.� t -. .'- , 4 : h - I , , I -y V t , I L 4+ ..-♦�. tet -r , Y 4— i { I -!- l I --I-•+ I ! ', -: — - 1 • - - ! �_� t—E•i•.—. . { + ; + 1 1 Ire I I l I- h + 1—I- 1 I+ r —, 4 1• . + .L! ; ! I -1-4--I-+1 1 .-+-.--4-- 41- r 1 1 1 ' � -�-. , 1-i _.. 4. I I 1. -: i T _,_.+_,.,m(1--101.1.1.11 ----!_I- - Ifl-I- -t+ r - i-+ -++r _+ I 1 t� : 1._ } , { . � ;-? f 14 -+ + f 1 ! --, ,--H+- 1 ( I --t + -,ti--- 4 -I- 1 ! 1 IIC T SYSTEM DEMAND @ CITY CONNECTION 807.29 GPM AT 41.19 PSI ( INCLUDES 500 GPM FOR HOSE STREP SYSTEM DEMAND @ BASE OF RISER 557.29 GPM AT 35.96 PSI ( INCLUDES 250 GPM FOR HOSE STRE 4 I , -+—p. -'—r--- ' , -, , I -1 4 ; ---1 I- 1 - _.. .�. ; 4 ;_,_ ' ' -`^t- 1 . l j �. +4 ; I -!- - + 1 a i—� -:� 1 + "y -f_-4-• -_ I_t •ty_T 1.' 1 4 --. - 1 -rt--'-- 4-) ,--i-. •'_ -4___-r-_4---- - +�,� 1 I. 4 I I i 11 • 1 4' ISI4 t r 4 11 I 1' , t 1 ' ' —x—.11 4 - -r-'� t-+ a'- ' .4- ,',r 4 -1 '4 -I, i i - I ._,;_ r-1- I 1 - Y -.-. 4 4 4 , , F - - 4 ' +-'-, '' 1 '. --t- �. L '-� .1 '. I t + I , -f----44--4 1 4 I 1, r - -4-- r- I, I -+..+ y 1. I 4 11 1 4 :'-F- I t I. 4, r 4 1+i,- -I-1 j-, -4--, • r -, 4 I E I -, t' 4R ± I- j • l 1 y , t4l 4 11 _ .1.--' - .,.-4-.....- ,- + . 4�+ 1 t 4 � t f { � 4 'I 1 1 1 '4-1-I- 1 1 I ' 1' l i r_ 111 1' I 1 14 4 ! ,, +-'rt t { , ', ' .4 1 , t 4 �r-,-1�,--s f 1 4 r 4- i • ' �----4-1'1 ' ' ' ' ' 1 , , ' + - ' I -- ' 1 ', _4-4-- '-, -1--+- 1 '-rr r , i . : -1-4-/ -4 4 t t 4-,--1--,-;- 4 f j 1 �� 4 I I -•!-. I r . ++ i" +1 11 4 ' I _4-� ' , + r 4` r r ' 1 + ' 1--4 1 ' 1-17- , 4 1 1 ' + rt- ' , I 4 I H 1 1 : i 1 T 1_I fi-• { -1 1 .w+__1- I.- - --' L• r. , l I I •4 �I4. 1-' ' , 6 +-- ', II ! t }-- '4 .1 1•' j1.4 pit -+--F-• + ! 1 !' - -!--1-- r : F -Y-4--- IT I 4- -- 74 1-; 4 4.- .✓ 4 I 4 1 I -. 1 + 4- ,----:--,--H _ I 4 f 1 I -1 1--+ , r , .'._I I ? 4 ; i I '- r--r--i- ' -{ 1 1 1 -'++ 4- . , i . r l 1 : t r 11 f, , j• 1- + 1 • t 4 I 1 , r1 , 4 1 F- -r t 4 1 1 T ,+I- Hi i 01/11/02 F11 08:38 FAN 253 926 2350 SMITH FIRE SYSTEMS Z004 DESIGN CRITERIA STORAGE AREAS: MINI STORAGE NOT TO EXCEED 12 FT. PER NFPA 13 - 1996 EDITION - ORDINARY HAZARD GP It BASE DESIGN DENSITY: 0.20 GPM/SQ.FT. OVER 1500 SQ.FT. SECTION 5-2.3.2.4 ALLOWS A 40 PERCENT REDUCTION IN THE DESIGN AREA WITHOUT REDUCING THE DENSITY WHERE LISTED QUICK -RESPONSE SPRINKLERS ARE USED THROUGHOUT AND WHEN ALL THE FOLLOWING CONDITIONS ARE MET: 1) WET PIPE SYSTEM. 2) LIGHT HAZARD OR ORDINARY HAZARD OCCUPANCY. 3) 20 FOOT MAXIMUM CEILING HEIGHT. x = CEILING HEIGHT = 1t-3" y = PERCENT REDUCTION TO DESIGN AREA y = -3x / 2 + 55 y = -3(11.25) / 2 + 55 y = 38.12 % 1500 x 0.62 = 930 SQ.FT. FINAL DESIGN DENSITY: 0.20 GPM/SQ.FT. OVER 930 SQ.FT. 01/11/02 FRI 08:38 FAX 253 926 2350 SMITH FIRE SYSTEMS Q005 AUXILIARY SUBMITTAL SERIAL N0:2244HY8 SOUTHCENTFR STORAGE / SFS JOB # T2-229 WET SYSTEM - 3RD FLOOR, SOUTHEAST CORNER MOST DEMANDING AREA DENSITY: 0.20 GPM OVER 930 SQ.FT. FILE NAME: T222953 FLOW TEST RESULTS Water Supply STATIC 120.00 PSI RESIDUAL 20.00 PSI @ 1767.00 GPM CITY PRESSURE AVAILABLE AT 807.3 GPM 96.52 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 749 20.07 20.00 750 20.10 15.00 751 20.60 14.87 752 20.61 14.87 753 20.65 14.87 736 20.00 20.00 737 20.04 15.00 738 20.53 14.87 739 20.54 14.87 740 20.58 14.87 732 21.13 24.87 732 21.14 14.87 848 20.66 15.00 851 20.25 14.87 853 20.37 14.87 5.62 12.76 5.62 12.79 5.62 13.44 5.62 13.45 5.62 13.50 5.62 12.66 5.62 12.71 5.62 13.35 5.62 13.36 5.62 13.42 5.62 14.14 5.62 14.15 5.62 13.51 5.62 12.98 5.62 13.14 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 3 OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 648 TO 848 307.29 GPM 250.00 GPM 250.00 GPM 807.29 GPM 41.19 PSI 0.00 PSI 7.67 FPS 01-11-2002 PAGE 1 01/11/02 FRI 08:39 FAX 253 926 2350 SMITH FIRE SYSTEMS 1¢1006 AUXILIARY SUBMITTAL SERIAL NO:2244HY8 SOUTHCENTER STORAGE / SFS JOB # T2-229 WET SYSTEM - 3R0 FLOOR, SOUTHEAST CORNER MOST DEMANDING AREA DENSITY: 0.20 GPM OVER 930 SQ.FT. FILE NAME: T2229S3 01-11-2002 PAGE 2 FROM TO FLOW LENGTH FITTING DIAM TYPE PSI/Ft S -LOSS PRESSURES 536 736 20.00 0.67 5.0 1.049 AO 0.130 0.00 13.40 12.66 653 853 20.37 3.67 7.0 1.049 DR 0.135 -0.87 13.71 13.14 187 653 20.37 2.08 12.0 1.728 BN7 0.012 0.00 13.88 13.71 651 651 20.25 4.50 7.0 1.049 DR 0.133 -0.87 13.64 12.98 186 651 20.25 2.08 12.0 1.728 BN6 0.012 0.00 13.80 13.64 648 848 20.66 3.83 7.0 1.049 DR 0.138 -0.87 14.14 13.51 183 646 20.66 2.08 6.0 1.728 BN4 0.012 0.00 14.24 14.14 143 183 20.66 0.67 12.0 1.728 NR 0.012 0.29 14.68 14.24 550 750 20.10 4.58 7.0 1.049 DR 0.131 -0.87 13.44 12.79 537 737 20.04 4.58 7.0 1.049 DR 0.131 -0.87 13.35 12.71 549 749 20.07 0.67 5.0 1.049 AO 0.131 0.00 13.50 12.76 144 143 16.34 2.67 0.0 4.310 CM1 0.000 0.00 14.68 14.68 145 144 50.59 3.33 0.0 4.310 CM1 0.001 0.00 14.68 14.68 146 145 50.59 6.67 0.0 4.310 CM1 0.001 0.00 14.68 14.68 147 146 125.07 10.00 0.0 4.310 CM1 0.004 0.00 14.72 14.68 148 147 198.00 10.00 0.0 4.310 CM1 0.009 0.00 14.81 14.72 149 148 166.29 10.00 0.0 4.310 CM1 0.007 0.00 14.68 14.81 150 149 135.50 10.00 0.0 4.310 CM1 0.005 0.00 14.93 14.88 151 150 105.36 6.83 0.0 4.310 CM1 0.003 0.00 14.95 14.93 152 151 76.96 2.67 6.0 4.310 CM1 0.002 0.00 14.96 14.95 153 152 30.99 9.00 30.0 4.310 CM1 0.000 -0.29 14.68 14.96 131 153 30.99 131.00 31.0 2.203 BL16 0.008 0.00 15.96 14.68 130 131 30.99 9.25 36.0 6.357 CM 0.000 0.29 16.25 15.96 192 152 45.96 0.67 14.0 2.203 RN1 0.016 -0.29 14.92 14.97 99 192 45.96 27.33 14.0 2.203 BL15 0.016 0.00 15.60 14.92 98 99 29.68 29.92 0.0 2.203 BL15 0.007 0.00 15.82 15.60 97 98 18.36 28.42 0.0 2.203 BL15 0.003 0.00 15.91 35.82 170 97 9.88 40.87 21.0 2.203 BL15 0.001 0.00 15.97 15.91 130 170 9.88 0.67 14.0 2.203 RN 0.001 0.29 16.27 15.97 129 130 40.87 4.00 0.0 6.357 CM 0.000 0.00 16.27 16.27 169 97 8.48 41.83 45.0 2.203 9L14 0.001 0.00 15.96 15.90 129 169 8.48 0.67 14.0 2.203 RN 0.001 0.29 16.26 15.96 128 129 49.35 7.67 0.0 6.357 CM 0.000 0.00 16.26 16.26 168 98 11.32 70.08 45.0 2.203 BL13 0.001 0.00 15.95 15.81 128 168 11.32 0.67 14.0 2.203 RN 0.001 0.29 16.26 15.95 127 128 60.67 10.00 0.0 6.357 CM 0.000 0.00 16.26 16.26 01/11/02 FRI 08:40 FAX 253 926 2350 SMITH FIRE SYSTEMS 0007 AUXILIARY SUBMITTAL SERIAL NO:2244HY8 SOUTHCENTER STORAGE / SFS JOB # T2-229 WET SYSTEM - 3RD FLOOR, SOUTHEAST CORNER MOST DEMANDING AREA DENSITY: 0.20 GPM OVER 930 SQ.FT. FILE NAME: T2229S3 01-11-2002 PAGE 3 FROM TO FLOW LENGTH FITTING DIAM TYPE PSI/Ft S -LOSS PRESSURES 167 99 16.29 98.00 45.0 2.203 BL12 0.002 0.00 15.94 15.60 127 167 16.29 0.67 14.0 2.203 RN 0.002 0.29 16.27 15.94 126 127 76.96 10.00 0.0 6.357 CM 0.000 0.00 16.27 16.27 191 151 28.40 0.67 14.0 2.203 RN1 0.007 -0.29 14.77 14.96 166 191 28.40 124.00 42.0 2.203 BL11 0.007 0.00 15.88 14.77 126 166 28.40 0.67 14.0 2.203 RN 0.007 0.29 16.27 15.88 125 126 105.36 10.00 0.0 6.357 CM 0.000 0.00 16.27 16.27 190 150 30.15 0.67 14.0 2.203 RN1 0.007 -0.29 34.76 14.94 165 190 30.15 120.83 28.0 2.203 BL10 0.007 0.00 15.88 14.76 125 165 30.15 0.67 14.0 2.203 RN 0.007 0.29 16.28 15.88 124 125 135.50 10.00 0.0 6.357 CM 0.001 0.00 16.29 16.28 189 149 30.79 0.67 14.0 2.203 RN1 0.008 0.29 14.71 14.89 164 189 30.79 120.83 28.0 2.203 BL9 0.008 0.00 15.87 14.71 124 164 30.79 0.67 14.0 2.203 RN 0.008 0.29 16.27 15.87 123 124 166.29 10.00 0.0 6.357 CM 0.001 0.00 16.28 16.27 188 148 32.71 0.67 14.0 2.203 RN1 0.008 -0.29 14.65 14.82 766 188 31.71 3.92 14.0 2.203 BL8 0.008 0.00 14.80 14.65 765 766 31.71 6.00 0.0 2.203 BL8 0.008 0.00 14.85 14.80 764 765 31.71 6.00 0.0 2.203 BL8 0.008 0.00 14.90 14.85 563 764 31.71 7.00 0.0 2.203 BL8 0.008 0.00 14.96 14.90 562 563 31.71 7.50 0.0 2.203 BL8 0.008 0.00 15.02 14.96 163 562 31.71 90.42 14.0 2.203 BL8 0.008 0.00 15.88 15.02 123 163 31.71 0.67 14.0 2.203 RN 0.008 0.29 16.29 15.88 122 123 198.00 7.83 0.0 6.357 CM 0.001 0.00 16.30 16.29 752 751 11.30 6.00 0.0 2.203 2L7 0.001 0.00 13.45 13.44 753 752 31.91 6.00 0.0 2.203 BL7 0.008 0.00 13.50 13.45 187 753 52.56 3.92 14.0 2.203 BL7 0.021 0.00 13.88 13.50 147 187 72.93 0.67 14.0 2.203 RN1 0.038 0.29 14.73 13.88 550 751 9.30 7.00 0.0 2.203 BL7 0.001 0.00 13.45 13.44 549 550 29.41 7.50 0.0 2.203 BL7 0.007 0.00 13.50 13.45 548 549 49.48 10.00 0.0 2.203 BL7 0.019 0.00 13.69 13.50 88 548 49.48 5.42 14.0 2.203 BL7 0.019 0.00 14.05 13.69 537 738 7.43 7.00 0.0 2.203 BL6 0.001 0.00 13.35 13.35 536 537 27.47 7.50 0.0 2.203 BL6 0.006 0.00 13.40 13.35 535 536 47.47 10.00 0.0 2.203 BL6 0.017 0.00 13.57 13.40 87 535 47.47 5.42 7.0 2.203 BL6 0.017 0.00 13.79 13.57 77 87 47.47 0.54 14.0 2.203 RN3 0.017 0.23 14.27 13.79 78 77 6.29 10.00 0.0 2.203 CM3 0.000 0.00 14.27 14.27 88 78 6.29 0.54 14.0 2.203 RN3 0.000 -0.23 14.05 14.27 01/11/02 FR1 08:41 FAX 253 926 2350 SMITH FIRE SYSTEMS 0008 AUXILIARY SUBMITTAL SERIAL NO:2244HY8 SOUTHCENTER STORAGE / SFS JOB # T2-229 WET SYSTEM - 3RD FLOOR, SOUTHEAST CORNER MOST DEMANDING AREA DENSITY: 0.20 GPM OVER 930 SQ.FT. FILE NAME: T2229S3 01-11-2002 PAGE 4 FROM TO FLOW LENGTH FITTING DIAM TYPE PSI/Ft S -LOSS PRESSURES 83 88 55.77 25.00 14.0 2.203 BL7 0.023 0.00 14.96 14.05 162 83 37.10 52.17 28.0 2.203 BL7 0.011 0.00 15.84 14.96 122 162 37.10 0.67 14.0 2.203 RN 0.011 0.29 16.29 15.84 121 122 235.10 1.17 0.0 6.357 CM 0.002 0.00 16.29 16.29 739 738 13.10 6.00 0.0 2.203 HL6 0.002 0.00 13.36 13.35 740 739 33.64 6.00 0.0 2.203 2L6 0.009 0.00 13.42 13.36 186 740 54.23 3.92 14.0 2.203 BL6 0.022 0.00 13.82 13.42 146 186 74.48 0.67 14.0 2.203 RN1 0.040 0.29 14.70 13.82 732 731 13.10 6.00 0.0 2.203 BLS 0.002 0.00 14.15 14.14 184 732 34.24 3.92 7.0 2.203 BLS 0.009 0.00 14.25 14.15 144 184 34.24 0.67 14.0 2.203 RN1 0.009 0.29 14.68 14.25 730 731 8.03 6.00 0.0 2.203 BLS 0.001 0.00 14.14 14.14 86 730 8.03 29.92 7.0 2.203 BL5 0.001 0.00 14.16 14.14 76 86 8.03 0.54 14.0 2.203 RN3 0.001 0.23 14.40 14.16 76 77 41.18 10.00 0.0 2.203 CM3 0.013 0.00 14.41 14.28 75 76 49.21 5.12 0.0 2.203 CM3 0.019 0.00 14.51 14.41 85 75 10.38 0.54 14.0 2.203 RN3 0.001 -0.23 14.29 14.51 182 85 10.38 50.71 35.0 2.203 BL4 0.001 0.00 14.38 14.29 142 182 10.38 0.67 14.0 2.203 RN1 0.001 0.29 14.68 14.38 74 75 38.82 0.54 0.0 2.203 CM3 0.012 0.00 14.52 14.51 84 74 38.82 0.54 14.0 2.203 RN3 0.012 -0.23 14.46 14.52 81 84 53.52 26.50 0.0 2.203 BL1 0.022 0.00 15.04 14.46 71 81 4.46 0.54 24.0 2.203 RN2 0.000 0.23 15.27 15.04 72 71 4.46 9.75 0.0 2.203 CM2 0.000 0.00 15.27 15.27 82 72 23.13 0.54 14.0 2.203 RN2 0.005 -0.23 15.11 15.27 79 82 23.13 26.25 27.0 2.203 BL3 0.005 0.00 15.35 15.11 142 143 4.31 7.33 0.0 4.310 CM1 0.000 0.00 14.68 14.68 141 142 14.69 6.50 0.0 4.310 CM1 0.000 0.00 14.68 14.68 140 141 6.65 8.25 0.0 4.310 CM1 0.000 0.00 14.68 14.68 180 140 6.65 0.67 14.0 2.203 RN1 0.001 -0.29 14.40 14.68 89 180 6.65 50.08 38.0 2.203 BL2 0.001 0.00 14.44 14.40 181 141 8.04 0.67 14.0 2.203 RN1 0.001 -0.29 14.40 14.68 89 181 8.04 41.25 17.0 2.203 BL1 0.001 0.00 14.44 14.40 84 89 14.69 6.50 0.0 2.203 BL1 0.002 0.00 14.45 14.44 80 81 49.06 14.83 0.0 2.203 BL1 0.018 0.00 15.30 15.03 79 80 19.45 12.75 0.0 2.203 BL1 0.003 0.00 15.34 15.30 161 79 42.58 25.42 7.0 2.203 BL1 0.014 0.00 15.80 15.34 121 161 42.58 0.67 14.0 2.203 RN 0.014 0.29 16.30 15.80 120 121 277.68 8.37 36.0 6.357 CM 0.003 0.00 16.42 16.30 01/11/02 FRI 08:41 FAX 253 926 2350 SMITH FIRE SYSTEMS 01009 AUXILIARY SUBMITTAL SERIAL NO:2244HY8 SOUTHCENTER STORAGE / SFS JOB # T2-229 WET SYSTEM - 3RD FLOOR, SOUTHEAST CORNER MOST DEMANDING AREA DENSITY: 0.20 GPM OVER 930 SQ.FT. FILE NAME: T2229S3 01-11-2002 PAGE 5 FROM TO FLOW LENGTH FITTING DIAM TYPE PSI/Ft S -LOSS PRESSURES 160 80 29.61 50.42 49.0 2.203 BL 0.007 0.00 16.02 15.30 120 160 29.61 0.67 14.0 2.203 RN 0.007 0.29 16.42 26.02 73 83 18.67 0.54 14.0 2.203 RN2 0.003 0.23 15.25 14.97 72 73 18.67 7.00 0.0 2.203 CM2 0.003 0.00 15.27 15.25 10 120 307.29 1.75 18.0 6.357 FM 0.003 0.00 16.48 16.42 9 10 307.29 6.62 72.0 6.357 FR3 0.003 2.46 19.19 16.48 5 9 307.29 37.96 38.0 6.357 FR2 0.003 16.45 35.88 19.19 4 5 307.29 1.33 16.0 6.357 FR1 0.003 0.00 35.94 35.88 3 4 307.29 0.67 20.0 8.249 FR 0.001 0.00 35.96 35.94 COMMENT: 250 GPM ADDED AT NODE 3 FOR INSIDE HOSE ALLOWANCE 2 3 557.29 78.00 26.0 8.265 UN2 0.002 0.00 36.17 35.96 1 2 557.29 5.42 0.0 8.071 UN1 0.003 4.77 40.96 36.17 COMMENT: ADDED 11' OF ELEVATION TO REPRESENT 4.5 LBS LOSS THRU COMMENT: 8 INCH FEBCO MODEL 856 DOUBLE DETECTOR CHECK ASSEMBLY 0 1 557.29 72.00 58.0 8.265 UN 0.002 0.00 41.22 40.96 COMMENT: 250 GPM ADDED AT NODE 0 FOR OUTSIDE HOSE ALLOWANCE JOB NAME: SOUTHCENTER STORAGE JOB NO. T2-229 NFPA 13 - 1996 SWAY BRACE CALCULATIONS BRACE DESIGNATION : 1) TYPE OF BRACE : 2) CALCULATED LOAD : 1 ❑ LATERAL ❑ LONGITUDINAL 0 4 - WAY SIZE OF PIPE TO BE BRACED SCHEDULE OF PIPE TO BE BRACED LENGTH OF PIPE TO BE BRACED WEIGHT OF WAT FILLED PIPE / FT. LOAD WEIGHT 1 40 1.027 1 1/4 SF 0.935 1 1/2 SF 1.355 2 SF 1.895 2 1/2 SF 2.550 3 SF 3.590 4 SF 5.430 5 10 8.650 6 10 21.00 11.520 241.920 8 10 20.040 241.920 I TOTAL CALCULATED LOADI 3) SIZE & TYPE OF BRACE MATERIAL : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 ) 4) MAXIMUM LENGTH OF BRACE : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.51 5) BRACE TYPE : B ( PER NFPA 13 1996 TABLE 4-14.4.3.5.6 ) 1" SCHEDULE 40 STEEL PIPE SIZE 7 - 0" DESIGN ANGLE : 52 o FROM VERTICAL 6) MAXIMUM HORIZONTAL LOAD FROM VERTICAL : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 ) (37-52- 75) 2,500 LBS. @ 45 TO 59 D 7) SWAY BRACE COMPONENTS : MANUFACTURER MODEL SIZE ALLOWABLE LOAD PIPE ATTACHMENT TOLCO 907 1" 655 LBS. STRUCTURE ATTACHMENT TOLCO 980 1" 2765 LBS. SFS DOCS\DESIGN TEMPLATES\SWAY BRACE CALCS 8) BRACE ANGLE ALLOWABLE HORIZONTAL LOAD ( PER NFPA 13 1996 TABLE 4-14.4.3.5.7 ) 30° - 44° FROM VERTICAL 45° - 59° FROM VERTICAL 59° - 90° FROM VERTICAL DIVIDED BY A SAFETY FACTOR OF 2.00 DIVIDED BY A SAFETY FACTOR OF 1.414 DIVIDED BY A SAFETY FACTOR OF 1.155 ALLOWABLE LOAD PER BRACE ATTACHMENT / SAFETY FACTOR = ADJUSTED LOAD PIPE ATTACHMENT 655 / 1.414 = 463.22 STRUCTURE ATTACHMENT 2765 / 1.414 = 1955.45 IF THE TOTAL CALCULATED LOAD IS GREATER THAN EITHER SWAY BRACE COMPONENT ADJUSTED LOAD, THEN ADDITIONAL BRACES ARE REQUIRED AND YOU MUST RE -DESIGN 9) TYPE OF STRUCTURE TO BE FASTENED TO : CONCRETE 10) TYPE OF FASTENER : 2 KW I K BOLT 1/2" X 3 3/4" 2 1/2" SIZE ❑ LAG SCREW x LENGTH MIN. EMBED SIZE LENGTH ❑ BOLT x SIZE LENGTH ❑ WELD x WELD THROAT LINEAL INCHES ❑ OTHER 11) ALLOWABLE LOAD PER FASTENER : 1782 Ibs. ( PER NFPA 13 - 1996 TABLE 4-14.4.3.5.6) or 1/8" WELD PER LINEAL INCH = 1800 Ibs. 3/16" WELD PER LINEAL INCH = 3900 Ibs. 1/4" WELD PER LINEAL INCH = 5200 Ibs. 12) NUMBER OF FASTENERS REQUIRED : TOTAL CALCULATED LOAD ALLOWABLE LOAD / FASTENER = 241.920 = 0.14 1782 REQUIRED NUMBER OF FASTENERS (ROUNDED UP TO NEAREST WHOLE NUMBER ADDITIONAL COMMENTS : 1 SFS DOGS \DESIUN 1 EMPLA I ES\SWAY 13NALE GALLS JOB NAME: SOUTHCENTER STORAGE JOB NO. T2-229 NFPA 13 - 1996 SWAY BRACE CALCULATIONS BRACE DESIGNATION : 2 1) TYPE OF BRACE : 2) CALCULATED LOAD : ❑ LATERAL ❑ LONGITUDINAL 0 4 - WAY SIZE OF PIPE TO BE BRACED SCHEDULE OF PIPE TO BE BRACED LENGTH OF PIPE TO BE BRACED WEIGHT OF WAT FILLED PIPE / FT. LOAD WEIGHT 1 40 1.027 1 1/4 SF 0.935 1 1/2 SF 1.355 2 SF 1.895 2 1/2 SF 2.550 3 SF 3.590 4 SF 5.430 5 10 8.650 6 10 21.00 11.520 241.920 8 10 20.040 241.920 1 TOTAL CALCULATED LOADI 3) SIZE & TYPE OF BRACE MATERIAL : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5) 4) MAXIMUM LENGTH OF BRACE : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5) 5) BRACE TYPE : E ( PER NFPA 13 1996 TABLE 4-14.4.3.5.6 ) 1" SCHEDULE 40 STEEL. PIPE SIZE 7 - 0" DESIGN ANGLE : 52 o FROM VERTICAL (37-52- 75) 6) MAXIMUM HORIZONTAL LOAD FROM VERTICAL : 2,500 LBS. @ 45 TO 1 PER NFPA 13 1996 TABLE 4-14.4.3.5.5 ) 59 0 7) SWAY BRACE COMPONENTS : MANUFACTURER MODEL SIZE ALLOWABLE LOAD PIPE ATTACHMENT TOLCO 907 1" 655 LBS. STRUCTURE ATTACHMENT TOLCO 980 1" 2765 LBS. SFS DOCS\DESIGN TEMPLATES\SWAY BRACE CALCS 8) BRACE ANGLE ALLOWABLE HORIZONTAL LOAD ( PER NFPA 13 1996 TABLE 4-14.4.3.5.7 ) 30° - 44° FROM VERTICAL 45° - 59° FROM VERTICAL 59° - 90° FROM VERTICAL DIVIDED BY A SAFETY FACTOR OF 2.00 DIVIDED BY A SAFETY FACTOR OF 1.414 DIVIDED BY A SAFETY FACTOR OF 1.155 ALLOWABLE LOAD PER BRACE ATTACHMENT / SAFETY FACTOR = ADJUSTED LOAD PIPE ATTACHMENT 655 / 1.414 = 463.22 STRUCTURE ATTACHMENT 2765 / 1.414 = 1955.45 IF THE TOTAL CALCULATED LOAD IS GREATER THAN EITHER SWAY BRACE COMPONENT ADJUSTED LOAD, THEN ADDITIONAL BRACES ARE REQUIRED AND YOU MUST RE -DESIGN 9) TYPE OF STRUCTURE TO BE FASTENED TO : WOOD 10) TYPE OF FASTENER : ❑ KWIK BOLT SIZE X LENGTH MIN. EMBED 2 LAG SCREW 1/2" X 4 SIZE LENGTH ❑ BOLT x SIZE LENGTH ❑ WELD x WELD THROAT LINEAL INCHES ❑ OTHER 11) ALLOWABLE LOAD PER FASTENER : 509 Ibs. ( PER NFPA 13 - 1996 TABLE 4-14.4.3.5.6) or 1/8" WELD PER LINEAL INCH = 1800 Ibs. 3/16" WELD PER LINEAL INCH = 3900 lbs. 1/4" WELD PER LINEAL INCH = 5200 Ibs. 12) NUMBER OF FASTENERS REQUIRED : TOTAL CALCULATED LOAD ALLOWABLE LOAD / FASTENER = 241.920 = 0.48 509 REQUIRED NUMBER OF FASTENERS (ROUNDED UP TO NEAREST WHOLE NUMBER ) ADDITIONAL COMMENTS : 1 SFS UULS\UESI(5N 1 EMI'LA 1 ES\SWAY LIKAUE (:ALUs JOB NAME: SOUTHCENTER STORAGE JOB NO. T2-229 NFPA 13 - 1996 SWAY BRACE CALCULATIONS BRACE DESIGNATION : 3 1) TYPE OF BRACE : 2) CALCULATED LOAD : ❑ LATERAL Q LONGITUDINAL ❑ 4 - WAY SIZE OF PIPE TO BE BRACED SCHEDULE OF PIPE TO BE BRACED LENGTH OF PIPE TO BE BRACED WEIGHT OF WAT FILLED PIPE / FT. LOAD WEIGHT 1 40 1.027 1 1/4 SF 0.935 1 1/2 SF 1.355 2 SF 1.895 2 1/2 SF 2.550 3 SF 3.590 4 SF 5.430 5 10 8.650 6 10 80.00 11.520 921.600 8 10 20.040 TOTAL CALCULATED LOADI 921.600 3) SIZE & TYPE OF BRACE MATERIAL : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 I 4) MAXIMUM LENGTH OF BRACE : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5) 5) BRACE TYPE : B ( PER NFPA 13 1996 TABLE 4-14.4.3.5.6 ) 1" SCHEDULE 40 STEEL, PIPE SIZE 7 0" DESIGN ANGLE : 52 o FROM VERTICAL (37-52- 75 6) MAXIMUM HORIZONTAL LOAD FROM VERTICAL : 2,500 LBS. @ 45 TO ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 ) 59 0 7) SWAY BRACE COMPONENTS : MANUFACTURER MODEL SIZE ALLOWABLE LOAD PIPE ATTACHMENT TOLCO 4A 1" 2015 LBS. STRUCTURE ATTACHMENT TOLCO 980 1" 2765 LBS. SFS DOCS\DESIGN TEMPLATES\SWAY BRACE CALCS 8) BRACE ANGLE ( PER NFPA 13 1996 TABLE 4-14.4.3.5.71 30° - 44° FROM VERTICAL 45° - 59° FROM VERTICAL 59° - 90° FROM VERTICAL ALLOWABLE HORIZONTAL LOAD DIVIDED BY A SAFETY FACTOR OF 2.00 DIVIDED BY A SAFETY FACTOR OF 1.414 DIVIDED BY A SAFETY FACTOR OF 1.155 ALLOWABLE LOAD PER BRACE ATTACHMENT / SAFETY FACTOR = ADJUSTED LOAD PIPE ATTACHMENT 2015 / 1.414 = 1425.04 STRUCTURE ATTACHMENT 2765 / 1.414 = 1955.45 IF THE TOTAL CALCULATED LOAD IS GREATER THAN EITHER SWAY BRACE COMPONENT ADJUSTED LOAD, THEN ADDITIONAL BRACES ARE REQUIRED AND YOU MUST RE -DESIGN 9) TYPE OF STRUCTURE TO BE FASTENED TO : CONCRETE 10) TYPE OF FASTENER : 2 KWIK BOLT 1/2" X 3 3/4" 2 1/2" SIZE ❑ LAG SCREW x LENGTH MIN. EMBED SIZE LENGTH ❑ BOLT x SIZE LENGTH ❑ WELD X WELD THROAT LINEAL INCHES ❑ OTHER 11) ALLOWABLE LOAD PER FASTENER : 1782 Ibs. ( PER NFPA 13 - 1996 TABLE 4-14.4.3.5.6) or 1/8" WELD PER LINEAL INCH = 1800 Ibs. 3/16" WELD PER LINEAL INCH = 3900 Ibs. 1/4" WELD PER LINEAL INCH = 5200 Ibs. 12) NUMBER OF FASTENERS REQUIRED : TOTAL CALCULATED LOAD ALLOWABLE LOAD / FASTENER = 921.600 = 0.52 1782 REQUIRED NUMBER OF FASTENERS (ROUNDED UP TO NEAREST WHOLE NUMBER ADDITIONAL COMMENTS : 1 SFS DOGS \DESIGN 1 EMPLA 1 ES\SWAY BRACE CALLS JOB NAME: SOUTHCENTER STORAGE JOB NO. T2-229 NFPA 13 - 1996 SWAY BRACE CALCULATIONS BRACE DESIGNATION : 1) TYPE OF BRACE : 2) CALCULATED LOAD : 4 Q LATERAL u LONGITUDINAL 0 4 - WAY SIZE OF PIPE TO BE BRACED SCHEDULE OF PIPE TO BE BRACED LENGTH OF PIPE TO BE BRACED WEIGHT OF WAT FILLED PIPE / FT. LOAD WEIGHT 1 40 20.00 1.027 20.540 1 1/4 SF 0.935 1 1/2 SF 49.00 1.355 66.395 2 SF 245.00 1.895 464.275 2 1/2 SF 2.550 3 SF 3.590 4 SF 5.430 5 10 8.650 6 10 40.00 11.520 460.800 8 10 20.040 TOTAL CALCULATED LOADI 1012.010 3) SIZE & TYPE OF BRACE MATERIAL : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5) 4) MAXIMUM LENGTH OF BRACE : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 1 5) BRACE TYPE : B ( PER NFPA 13 1996 TABLE 4-14.4.3.5.6 ) 1" SCHEDULE 40 STEEL PIPE SIZE 7 0" DESIGN ANGLE : 52 o FROM VERTICAL (37-52- 75) 6) MAXIMUM HORIZONTAL LOAD FROM VERTICAL : 2,500 LBS. @ 45 TO ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 ► 59 0 7) SWAY BRACE COMPONENTS : MANUFACTURER MODEL SIZE ALLOWABLE LOAD PIPE ATTACHMENT TOLCO 1000 1" 2015 LBS. STRUCTURE ATTACHMENT TOLCO 980 1" 2765 LBS. SFS DOCS\DESIGN TEMPLATES\SWAY BRACE CALCS 8) BRACE ANGLE ( PER NFPA 13 1996 TABLE 4-14.4.3.5.7 30° - 44° FROM VERTICAL 45° - 59° FROM VERTICAL 59° - 90° FROM VERTICAL ALLOWABLE HORIZONTAL LOAD DIVIDED BY A SAFETY FACTOR OF 2.00 DIVIDED BY A SAFETY FACTOR OF 1.414 DIVIDED BY A SAFETY FACTOR OF 1.155 ALLOWABLE LOAD PER BRACE ATTACHMENT / SAFETY FACTOR = ADJUSTED LOAD PIPE ATTACHMENT STRUCTURE ATTACHMENT 2015 / 1.414 = 1425.04 2765 / 1.414 = 1955.45 IF THE TOTAL CALCULATED LOAD IS GREATER THAN EITHER SWAY BRACE COMPONENT ADJUSTED LOAD, THEN ADDITIONAL BRACES ARE REQUIRED AND YOU MUST RE -DESIGN 9) TYPE OF STRUCTURE TO BE FASTENED TO : CONCRETE 10) TYPE OF FASTENER : 0 KWIK BOLT 1/2" ❑ LAG SCREW El BOLT SIZE X 3 3/4" 2 1/2" LENGTH MIN. EMBED x SIZE LENGTH x SIZE LENGTH ❑ WELD X WELD THROAT LINEAL INCHES ❑ OTHER 11) ALLOWABLE LOAD PER FASTENER : ( PER NFPA 13 - 1996 TABLE 4-14.4.3.5.6) or 1/8" WELD PER LINEAL INCH = 1800 Ibs. 3/16" WELD PER LINEAL INCH = 3900 Ibs. 1/4" WELD PER LINEAL INCH = 5200 Ibs. 12) NUMBER OF FASTENERS REQUIRED : TOTAL CALCULATED LOAD ALLOWABLE LOAD / FASTENER 1782 Ibs. 1012.010 = 0.57 1782 REQUIRED NUMBER OF FASTENERS (ROUNDED UP TO NEAREST WHOLE NUMBER ADDITIONAL COMMENTS : 1 SFS DUGS\UESIL,N I LM LA I Lb SWAY k3KAUE UAL(: JOB NAME: SOUTHCENTER STORAGE JOB NO. T2-229 NFPA 13 - 1996 SWAY BRACE CALCULATIONS BRACE DESIGNATION : 5 1) TYPE OF BRACE : 2) CALCULATED LOAD : ❑ LATERAL Q LONGITUDINAL ❑ 4 - WAY SIZE OF PIPE TO BE BRACED SCHEDULE OF PIPE TO BE BRACED LENGTH OF PIPE TO BE BRACED WEIGHT OF WAT FILLED PIPE / FT. LOAD WEIGHT 1 40 1.027 1 1/4 SF 0.935 1 1/2 SF 1.355 2 SF 1.895 2 1/2 SF 2.550 3 SF 3.590 4 SF 5.430 5 10 8.650 6 10 46.00 11.520 529.920 8 10 20.040 TOTAL CALCULATED LOADI 529.920 I 3) SIZE & TYPE OF BRACE MATERIAL : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 ) 4) MAXIMUM LENGTH OF BRACE : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 I 5) BRACE TYPE : I ( PER NFPA 13 1996 TABLE 4-14.4.3.5.6 I 1" SCHEDULE 40 STEEL PIPE SIZE 7 0" DESIGN ANGLE : 52 o FROM VERTICAL (37-52- 75) 6) MAXIMUM HORIZONTAL LOAD FROM VERTICAL : 2,500 LBS. @ 45 TO ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 ) 59 0 7) SWAY BRACE COMPONENTS : MANUFACTURER MODEL SIZE ALLOWABLE LOAD PIPE ATTACHMENT TOLCO 4A 1" 2015 LBS. STRUCTURE ATTACHMENT TOLCO 980 1" 2765 LBS. SFS DOCS\DESIGN TEMPLATES\SWAY BRACE CALCS 8) BRACE ANGLE ( PER NFPA 13 1996 TABLE 4-14.4.3.5.7 ) 30° - 44° FROM VERTICAL 45° - 59° FROM VERTICAL 59° - 90° FROM VERTICAL ALLOWABLE HORIZONTAL LOAD DIVIDED BY A SAFETY FACTOR OF 2.00 DIVIDED BY A SAFETY FACTOR OF 1.414 DIVIDED BY A SAFETY FACTOR OF 1.155 ALLOWABLE LOAD PER BRACE ATTACHMENT / SAFETY FACTOR = ADJUSTED LOAD PIPE ATTACHMENT 2015 / 1.414 = 1425.04 STRUCTURE ATTACHMENT 2765 / 1.414 = 1955.45 IF THE TOTAL CALCULATED LOAD IS GREATER THAN EITHER SWAY BRACE COMPONENT ADJUSTED LOAD, THEN ADDITIONAL BRACES ARE REQUIRED AND YOU MUST RE -DESIGN 9) TYPE OF STRUCTURE TO BE FASTENED TO : WOOD 10) TYPE OF FASTENER : ❑ KWIK BOLT SIZE X ❑ LAG SCREW x LENGTH MIN. EMBED SIZE LENGTH El BOLT 1/2" X 3" SIZE LENGTH ❑ WELD x WELD THROAT LINEAL INCHES ❑ OTHER 11) ALLOWABLE LOAD PER FASTENER : 548 Ibs. ( PER NFPA 13 - 1996 TABLE 4-14.4.3.5.6 ) or 1/8" WELD PER LINEAL INCH = 1800 Ibs. 3/16" WELD PER LINEAL INCH = 3900 Ibs. 1/4" WELD PER LINEAL INCH = 5200 Ibs. 12) NUMBER OF FASTENERS REQUIRED : TOTAL CALCULATED LOAD ALLOWABLE LOAD / FASTENER 529.920 = 0.97 548 REQUIRED NUMBER OF FASTENERS (ROUNDED UP TO NEAREST WHOLE NUMBER 1 ADDITIONAL COMMENTS : 1 SFS UUUS\UESII3N I EMI -LAI ES\SWAY bR:AUE CALLS JOB NAME: SOUTHCENTER STORAGE JOB NO. T2-229 NFPA 13 - 1996 SWAY BRACE CALCULATIONS BRACE DESIGNATION : 6 1) TYPE OF BRACE : 2) CALCULATED LOAD : Q LATERAL ❑ LONGITUDINAL ❑ 4 - WAY SIZE OF PIPE TO BE BRACED SCHEDULE OF PIPE TO BE BRACED LENGTH OF PIPE TO BE BRACED WEIGHT OF WA FILLED PIPE / FT. LOAD WEIGHT 1 40 20.00 1.027 20.540 1 1/4 SF 0.935 1 1/2 SF 49.00 1.355 66.395 2 SF 245.00 1.895 464.275 2 1/2 SF 2.550 3 SF 3.590 4 SF 5.430 5 10 8.650 6 10 40.00 11.520 460.800 8 10 20.040 TOTAL CALCULATED LOAD 1012.010 3) SIZE & TYPE OF BRACE MATERIAL : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 ) 4) MAXIMUM LENGTH OF BRACE : ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 ) 5) BRACE TYPE : F ( PER NFPA 13 1996 TABLE 4-14.4.3.5.6 ) 1" SCHEDULE 40 STEEL PIPE SIZE 7 - 0" DESIGN ANGLE : 75 o FROM VERTICAL (37-52- 75 6) MAXIMUM HORIZONTAL LOAD FROM VERTICAL : 2,500 LBS. @ 60 TO 90 ( PER NFPA 13 1996 TABLE 4-14.4.3.5.5 ) 7) SWAY BRACE COMPONENTS : MANUFACTURER MODEL SIZE ALLOWABLE LOAD PIPE ATTACHMENT TOLCO 1000 1" 2015 LBS. STRUCTURE ATTACHMENT TOLCO 980 1" 2765 LBS. SFS DOCS\DESIGN TEMPLATES\SWAY BRACE CALCS 8) BRACE ANGLE ( PER NFPA 13 1996 TABLE 4-14.4.3.5.7 ) 30° - 44° FROM VERTICAL 45° - 59° FROM VERTICAL 59° - 90° FROM VERTICAL ALLOWABLE HORIZONTAL LOAD DIVIDED BY A SAFETY FACTOR OF 2.00 DIVIDED BY A SAFETY FACTOR OF 1.414 DIVIDED BY A SAFETY FACTOR OF 1.155 ALLOWABLE LOAD PER BRACE ATTACHMENT / SAFETY FACTOR = ADJUSTED LOAD PIPE ATTACHMENT 2015 / 1.414 = 1425.04 STRUCTURE ATTACHMENT 2765 / 1.414 = 1955.45 IF THE TOTAL CALCULATED LOAD IS GREATER THAN EITHER SWAY BRACE COMPONENT ADJUSTED LOAD, THEN ADDITIONAL BRACES ARE REQUIRED AND YOU MUST RE -DESIGN 9) TYPE OF STRUCTURE TO BE FASTENED TO : WOOD 10) TYPE OF FASTENER : ❑ KWIK BOLT SIZE X ❑ LAG SCREW x LENGTH MIN. EMBED SIZE LENGTH BOLT 1/2" X 3" SIZE ❑ WELD x WELD THROAT ❑ OTHER LENGTH LINEAL INCHES 11) ALLOWABLE LOAD PER FASTENER : 1091 Ibs. ( PER NFPA 13 - 1996 TABLE 4-14.4.3.5.6 or 1/8" WELD PER LINEAL INCH = 1800 Ibs. 3/16" WELD PER LINEAL INCH = 3900 Ibs. 1/4" WELD PER LINEAL INCH = 5200 Ibs. 12) NUMBER OF FASTENERS REQUIRED : TOTAL CALCULATED LOAD ALLOWABLE LOAD / FASTENER = 1012.010 = 0.93 1091 REQUIRED NUMBER OF FASTENERS (ROUNDED UP TO NEAREST WHOLE NUMBER ADDITIONAL COMMENTS : 1 SFS DOLS \DESIGN I EMPLA I LS\SWAY BNAUL CALLS t - Global Project Values: SILENT Project Name: Southcenter Storage Standby Hours: 24 KNIC I Irl Project ID: 1412 Alarm Mins: 5 Prepared By: MM Derating Factor: 1.2 58 0XL Calculations Date: 3/8/2002 Voltage Drop Waming Threshold % . 10 Panel ID: 5820XL Model: 5820XL Addressable Fire Alarm Control Max NAC Current: 3.0 Amps Location: Tukwilla, WA Volts: 24 VDC Max Panel Current: 5.0 Amps Ckt.# Circuit Name Qty Current Draw Standby Alarm Wire AWG Ohms Per Length(ft) Actual Volts la %Drop & Type 1000 Ft. One -Way Ohms EOL 5820XL 5820XL Main Control 1 0.140 0.260 , .,` SLC -DEV Addrsbl SLC Devices 19 0.001 0.010 5815XL SLC Loop Expander 0.000 0.000 5860 LCD Remote Annunc 1 0.020 0.025 5824 Serial/Parallel Module 0.000 0.000 5895XL Power Expander 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 S0505-6SB Sounder Base 0.000 0.000 SD505-6RB Relay Base 0.000 0.000 SD -Duct Duct Hsq w/Relav 0.000 0.000 5883 Relay Module 0.000 0.000 PGM -I/O #1 Notification Appl Circuit 0.000 1.480 #12 Solid 2.52 0.00 24.00 0.00% PGM -I/O #2 Notification Appl Circuit 0.000 1.332 #12 Solid 1.59 0.00 24.00 0.00% PGM -I/O #3 Notification Appl Circuit 0.000 1.645 #12 Solid 1.59 0.00 24.00 0.00% PGM -I/O #4 Notification Appl Circuit 0.000 1.480 #12 Solid 1.59 0.00 24.00 0.00% PGM -I/O #5 Notification Appl Circuit 0.000 1.776 #12 Solid 1.59 0.00 24.00 0.00% PGM -I/O #6 Notification Appl Circuit 0.000 0.000 #12 Solid 1.59 0.00 24.00 0.00% Total Standby Current (Amps) 0.161 8.008 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 3.865 0.667 Total Alarm AH Required Total Combined AH Required 4.53 Command Shortcuts Multiply By The Derating Factor 1.20 c Minimum Battery AmpHours Required 5.44 [ Configure Circuits J Print Page 5820XL on the Web ri EXISTING CONC WALL EXISTING NORTH HILL APARTMENTS EXISTING WOOD FENCE EXISTING WD FFENCE EXISTING DRIVEWAY EXISTING CONC CURB & WALK • STAIR #1 NEW SELF STORAGE BUILDING 3 FLRS + 2 BSMTS AT 15,000 = 75,000 SF 8" FLANGE (LEFT BY OTHERS) SEE FLANGE LOCATION PLAN THIS SHEET FOR LOCATING DIMENSIONS SOUTHCENTER STORAGE AREA. 15,000 EA FLR - TOTAL 75,000± SQ FT OCCUPANCY GROUP: B & S1 CONSTRUCTION TYPE: II -1 HR SPRINKLERED FINISHED FLOOR ELEVATION 72 00 FEET O 8" DDCVA IN VAULT 0 SITE PLAN 10 20 30 40 50 SCALE 1" = 20' HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS in 0 UNDERGROUND NOTES: 1) ALL UNDERGROUND TO BE BY OTHERS. CONTRACTOR TO BE STATE LICENSED AND CERTIFIED TO INSTALL UNDERGROUND PIPING PER WAC 212-80 2) PIPE TYPE AND CLASS TO MEET LOCAL JURISDICTION APPROVAL 3) ALL UNDERGROUND PIPING SHALL HAVE 3 FEET MINIMUM BURY (TO TOP OF PIPE ). 1'-0" c.4" DIA SLEEVE FOR 21/2" DRAIN PIPING BLDG CORNER—, �" 8 DIA SLEEVE FOR 6" SUPPLY RISER LOCATED @ GRID 'K CC oz k O Ft 0 0 U c�9 4) ALL UNDERGROUND PIPING SHALL BE UL LISTED AND/OR FM APPROVED FOR FIRE PROTECTION 5) ALL UNDERGROUND PIPING SHALL BE RODDED AND/OR BLOCKED IN ACCORDANCE WITH THE SPECIFICATIONS AND NFPA 24 ( LATEST EDITION ). 6) ALL UNDERGROUND PIPING SHALL BE HYDRO- STATICALLY TESTED AT NOT LESS THAN 200 PSI OR 50 PSI ABOVE STATIC PRESSURE IN EXCESS OF 150 PSI FOR TWO HOURS IN ACCORDANCE WITH NFPA 24 ( LATEST EDITION ) 7) ALL UNDERGROUND PIPING SHALL BE FLUSHED IN ACCORDANCE WITH NFPA 24 ( LATEST EDITION ) FLOW THE REQUIRED RATE UNTIL WATER IS CLEAR AS INDICATED BY NO COLLECTION OF FOREIGN MATERIAL IN BURLAP BAGS AT OUTLETS 4" - 390 GPM 6" - 880 GPM 8" - 1,560 GPM 10" - 2,400 GPM 12" - 3,520 GPM 8) ALL UNDERGROUND PIPING SHALL BE STERILIZED PER LOCAL JURISDICTION REQUIREMENTS - RISER DETAIL RISER ( DETAIL U' 6\ P.1 /L oN 5'-10" WALL PENETRATION 8'-6" c.8" DIA. SLEEVE FOR 6" SUPPLY RISER 9'-1" 4" DIA SLEEVE FOR 21/2" DRAIN PIPING • (eyoTy�RsJ NOTES 1) f OF8"DICL52UG IS TO COME THRU THE SOUTH EXTERIOR WALL @ 5'-0" ABOVE BASEMENT 2 FLOOR 2) LOCATIONS OF SLEEVES ARE TYPICAL ON ALL FLOORS, EXCEPT BASEMENT 2 FLOOR SHALL HAVE A FLOOR DRAIN OF CAPABLE SIZE TO DISCHARGE WATER FROM A FULL FLOW TEST AND/OR THE DRAINING OF THE FIRE SPRINKLER SYSTEM N FLANGE LOCATION PLAN 1) 0 6 12 SCALE 3/16"=1'-0" FLOW TEST INFORMATION INFORMATION PROVIDED BY THE CITY OF TUKWILA STATIC PRESSURE 120 P.S.I. RESIDUAL PRESSURE : 20 P.S.I. FLOW DATE OF TEST ELEVATION : 1,767 G.P.M. FEB.1999 . 72 FEET SITE PLAN SYMBOLS NEW UNDERGROUND BY SFS INN im NEW UNDERGROUND BY OTHERS EXISTING UNDERGROUND PROPERTY UNE STREET CENTERLINE NEW FIRE HYDRANT EXISTING FIRE HYDRANT NEW YARD POST INDICATOR EXISTING YARD POST INDICATOR --l— NEW VALVE WITH ROADWAY BOX �Q— EXISTING VALVE WITH ROADWAY BOX • _ • • NEW TWO WAY FIRE DEPARTMENT CONNECTION EXISTING TWO WAY FIRE DEPARTMENT CONNECTION NEW FOUR WAY FIRE DEPARTMENT CONNECTION EXISTING FOUR WAY FIRE DEPARTMENT CONNECTION GENERAL NOTES 1. ALL PIPE TO BE AS FOLLOWS: STEEL PIPE ASTM A-795 OR BETTER PIPE SIZE SCHEDULE WALL THICKNESS INTERNAL DIAMETER END PREP TYPES ALLOWED WEIGHT OF WATER / PIPE CAPACITY IN GALLONS 1 40 0 133 1 049 THREAD, CUT GROOVED, ROLL GROOVED, PLAIN END, POLISHED 2 055 0 045 11/4 SUPER-FLO 0 062 1 536 ROLL GROOVED, POLISHED, PLAIN END (FOR BUTT WELDING) 1 870 0 096 11/2 SUPER-FLO 0 086 1.728 ROLL GROOVED, POLISHED, PLAIN END (FOR BUTT WELDING) 2 710 0 122 2 SUPER-FLO 0 086 2 203 ROLL GROOVED, POLISHED, PLAIN END (FOR BUTT WELDING) 3 790 0 198 21/2 SUPER-FLO 0 086 2 703 ROLL GROOVED, PLAIN END (FOR BUTT WELDING) 5 100 0 298 3 SUPER-FLO 0 093 3 314 ROLL GROOVED, PLAIN END (FOR BUTT WELDING) 7 180 0 448 4 SUPER-FLO 0 095 4 310 ROLL GROOVED, PLAIN END (FOR BUTT WELDING) 10 860 0 758 5 10 0 134 5 295 ROLL GROOVED, PLAIN END (FOR BUTT WELDING) 17 324 1 144 6 ** 0 134 6 357 ROLL GROOVED, PLAIN END (FOR BUTT WELDING) 23 058 1 649 8 ** 0 188 8 249 ROLL GROOVED, PLAIN END (FOR BUTT WELDING) 40 126 2 776 ** WALL THICKNESS PER NFPA #13 SCOPE OF WORK SMITH FIRE SYSTEM, INC. ( SFS) WILL PROVIDE AND INSTALL A WET PIPE FIRE SPRINKLER SYSTEM TO PROTECT THE HEATED INTERIOR OF THE BUILDING. INSTALLATION OF THE FIRE SPRINKLER SYSTEM WILL COMPLY TO NFPA #13,1996 EDITION, UTILIZING QUICK -RESPONSE SPRINKLERS. A CLASS 1 WET STANDPIPE SYSTEM WILL BE LOCATED IN EACH STAIRWELL WITH 2.5" HOSE VALVES ON INTERMEDIATE LANDINGS PER CITY OF TUKWILA RECOMMENDATIONS. SFS WILL BEGIN WORK INSIDE THE BUILDING AT AN 8" FLANGE LOCATED IN THE SOUTHEAST CORNER OF STAIR #1. SEE T FLANGE LOCATION PLAN ON THIS SHEET FOR LOCATION. CLARIFICATIONS: - -- ALL AREAS WHERE WET PIPE IS INSTALLED MUST BE MAINTAINED @ 40° F TO PREVENT FREEZING - -- SFS ASSUMES THAT THE STRUCTURE IS ADEQUATE TO SUPPORT THE WEIGHT OF THE WATER FILLED SPRINKLER SYSTEM EXCLUSIONS: - -- PAINTING AND/OR LABELING OF SPRINKLER PIPING --- ELECTRICAL WIRING OF ANY KIND, INCLUDING BUT NOT LIMITED TO: WATER FLOW INDICATOR AND ELECTRIC BELL --- CENTRAL STATION MONITORING, ALARM EQUIPMENT AND WIRING - -- ALL UNDERGROUND WORK, INCLUDING BUT NOT LIMITED TO: DESIGN, MATERIAL, TESTING AND CERTIFICATION --- DOUBLE DETECTOR CHECK VALVE ASSEMBLY (TO BE INSTALLED WITH UNDERGROUND BY OTHERS) --- FIRE DEPARTMENT CONNECTION (TO BE INSTALLED WITH UNDERGROUND BY OTHERS) DESIGN CRITERIA: PER WSRB & THE CITY OF TUKWILA * .15 GPM / SQ. FT. OVER 5,000 SQ. FT. * 100 SQ. FT. MAXIMUM SPRINKLER SPACING * UTILIZE QUICK -RESPONSE SPRINKLERS * 12' MAXIMUM STORAGE HEIGHT * 155° F CEILING SPRINKLERS SYMBOL LEGEND QUALITY CONTROL BY: DATE REVISIONS SYM MANUFACTURER TYPE MODEL HEAD FINISH ESCUTCHEON FINISH ORIFICE SIZE THREAD SIZE TEMP RATING QUANTITY AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURUN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO SPRINKLERS UNLESS NOTED OTHERWISE BOD CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO I DATE BY REASON FOR REVISION APPROVED FOR FABRICATION 1 111/30/01 BC PER CITY OF TUKWILA AREA BY DATE CONTRACT WITH CONSTRUCTION ASSOCIATES P.O. BOX 975 LYNNWOOD, WA. 98046-0975 PROJECT MANAGER : MARK GARRIBO PHONE : (425) 774-3821 FAX : (425) 774-9065 SUPERINTENDENT: PHONE: FAX : A-72 CERTIFICATE OF COMPETANCY STAMP ACCEPTED Without Comments ❑ As Noted In Red ❑ Per The Attached Letter These plans have been reviewed b' ; Fire Prevent, -in Bureau for C..0 i co rt':•. standards. Accei,"._ _ c rte omissions which d' ":1t aul :ori -- standards and Ord. ;a, Tv T., adequacy of des gn ; , Additions, deletions ; r re,.,, fi; _ ^�:R this date will void tills accept. ,.r, - r i ' - resubmittal of revised drawings for 51.1,1r„- . 4r1 - Final acceptance is subject to field test The Tukwila Fire Prevention Bureau. Date:/ -2- 7- O oZ By: TUKWILA FIRE DEPARTMENZ Please call: 575-4.407 and give this job 5 - -?(71 and exact aJ.Jres . tar shut= • down or restoration approval, KEY PLAN FT SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 98424 CONTR REG NO SMITHFS1360T Bus: ( 253) 926 - 1880 FAX: ( 253) 926 - 2350 SOUTHCENTER STORAGE 5950 SOUTHCENTER BLVD. TUKWILA, WASHINGTON DESIGNER B. COLLINS DATE 10/3/01 JOB NO. T2-229 • T.O.P. Z9 o) / THIRD FLOOR b b • SECOND FLOOR 0 EXTERIOR WALLS RISER EQUIPMENT ITEM QTY. SIZE DESCRIPTION MANUFACTURER MODEL # 1 6 6" 2 5 6" 3 5 2" 4 5 Ya" 5 5 Y2" 6 1 10" 7 2 12 HEAD BUTTERFLY VALVE W/ TAMPER SWITCH VICTAUUC WATER FLOW INDICATOR POTTER ELECTRIC DRAIN & INSPECTORS TEST VALVE W/'/2" ORIFICE -- PRESSURE GAGE PRESSURE RELIEF VALVE ELECTRIC BELL POTTER ELECTRIC SPARE HEAD CABINET CONTAINING THE FOLLOWING: MAN UFACTURER RELIABLE RELIABLE RELIABLE RELIABLE SPARE SPRINKLERS AND WRENCHES TYPE PENDENT UPRIGHT VSW DRY HSW MODEL G4QR F1 FR F1FR G3FR HEAD FINISH BRZ BRZ. BRZ. BRZ. -- RELIABLE MODEL D, G4 & RC1 SPRINKLER WRENCHES WET SYSTEM ( MOST DEMANDING AREA ) AREA AREA NUMBER OF DESCRIPTION SQ. FOOTAGE SPRINKLERS THIRD FLOOR 15,000± 210 HYDRAULIC CALCULATION DATA DESIGN DENSITY: .15 G.P.M. / 5,000 SQ. FT. ACTUAL DENSITY: .15 G.P.M. / 5,057 SQ. FT. DEMAND AT BASE OF RISER: 1,281.35 G.P.M. AT 51.57 P.S.I. (100 G.P.M. INSIDE HOSE ALLOWANCE) DEMAND AT CITY CONNECTION: 1,281.35 G.P.M. AT 58.59 P.S.I. (100 G.P.M. TOTAL HOSE ALLOWANCE) 5-4" ORIFICE SIZE v2' '/2" v2' 1' THREAD SIZE y" 1/2" 1" TEMP. RATING 165 155 QUANTIFY 10 12 200 1 155 1 1EA. - 708 W -- VSR-F -- PBD 2410 -- WET SYSTEM ( AUXILIARY CALCULATIONS ) AREA AREA NUMBER OF DESCRIPTION SQ. FOOTAGE SPRINKLERS BASEMENT 1 15,000± 184 HYDRAULIC CALCULATION DATA DESIGN DENSITY: .15 G.P.M. / 5,000 SQ. FT. ACTUAL DENSITY: .15 G.P.M. / 5,095 SQ. FT. DEMAND AT BASE OF RISER: 1,217.63 G.P.M. AT 52.93 P.S.I. (100 G.P.M. INSIDE HOSE ALLOWANCE) DEMAND AT CITY CONNECTION: 1,217.63 G.P.M. AT 59.73 P.S.I. (100 G.P.M. TOTAL HOSE ALLOWANCE) 5-4" 12 Ya STORAGE UNIT HALL STORAGE UNIT HALL STORAGE UNIT HALL STEEL ROOF SYSTEM WITH METAL ROOFING AND R-30 BATT INSUL STORAGE UNIT 5.5" CONC. SLAB ON METAL DECK HALL STORAGE UNIT 12 HALL STORAGE UNIT HALL STORAGE UNIT C C c EXTERIOR WALLS STORAGE UNIT HALL STORAGE UNIT 9'-6.5" CLEAR HALL STORAGE UNIT HALL STORAGE UNIT 5.5" CONC. SLAB ON METAL DECK HALL STORAGE UNIT HALL STORAGE UNIT HALL STORAGE UNIT STEEL STUDS WITH GWB EACH SIDE & METAL SIDING ON THE OUTSIDE - UNO • FIRST FLOOR FURRED CONCRETE WALL WITH VAPOR BARRIER b • BASEMENT 1 0 b 72-0" / BASEMENT 2 T.O.C. STORAGE UNIT HALL STORAGE UNIT 9'-6.5" CLEAR HALL STORAGE UNIT HALL STORAGE UNIT 12" POST -TENSIONED CONC. SLAB HALL STORAGE UNIT HALL STORAGE UNIT HALL STORAGE UNIT STORAGE UNIT HALL 9'-0" CLEAR STORAGE UNIT STEEL STUD INTERIOR WALLS W/ GWB EA. SIDE HALL STORAGE UNIT 8" POST -TENSIONED CONC. SLAB HALL STORAGE UNIT HALL STORAGE UNIT STORAGE UNIT HALL 9'-4" CLEAR STORAGE UNIT HALL HALL HALL STORAGE UNIT STEEL STUDS WITH GWB EACH SIDE & METAL SIDING ON THE OUTSIDE - UNO FURRED CONCRETE WALL WITH VAPOR BARRIER 9'-10" 51-4" 23'-4" 15-4" 5-4" 2'-10" 12-0" 12-0" 2'-10" 5-4" 15-4" 23'-4" 5-4" 9'-10" HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SYM MANUFACTURER TYPE MODEL HEAD FINISH ESCUTCHEON FINISH ORIFICE SEE THREAD SIZE TEMP. RATING QUANTITY AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE CROSS SECTION 0 6 12 --- - - - -—- - —— SCALE 3/16"=V-0" 14 AFF u)/ (0/ z 7'-0" O a, C1) / W cc e? W (0 / ;- CC io _/ 4'-0" CO/ Zb AFF AFF (9 N GOLD GOLD 2 X 0-9'/2 (0-31/2) 8'-5'/2" AFF ® T-0" AFF AFF AFF (13 CD/ Z O '/ Zug / c0 W ETD co/ SECOND FLOOR Cn 9 In (D BROWN (o 0 N 0 c%) Ix L) 6 m -c4 - Xi 6. 505 ;0-11.5) I I9,J• • Ott (o Q t<,� • v e Nth m (a ISI kSI I.j• (ID Iri 1-9 2 X 0-9v2 (0-3v) f r 41 8'-5.5" AFF Fn co/ ZD / Z ;- 0 '- Or 7'-a' —/ AFF Z io ro Wr Zo T 6 0 / 0 cc Z- ? z W CA AFF AFF FIRST FLOOR W a Ob Z / C/) (9 CV / io ORANGE In 0 6. 0 Thm 0 • (0 ;0-11.5) ILD; cm I- cn W 0_ e 0 N ED .6 2X0.9'/2 (0-31/2) N 4L) , ti 1-9 cb Lq W 8'-7 / i0▪ / AFF u� co/ Zo 7a' O AFF Z in CV / BASEMENT1 8'-3" AFF in CA co/ z_ O`1 7' 0" (7)co/ AFF Z[n 5y0_/ cc Q Z 0/ LU LUT LU CC Eo 1`0 4'-0" (o/ AFF 1'-0" AFF BASEMENT 2 BLUE GREEN 0 N, fD cv .4 PIPE STAND (D 0 m N GP g i Y 2.5" RISER CLAMP W/ (2) 3/8" X 5" KWIK BOLTS (TYP) 3 5 4 PIPE STAND 1 2 X 0-9'/2 (0-31/2) C7 -- x 5� — ti FLOOR DRAIN (BY OTHERS) —\ H6 6" RISER CLAMP /— W/ (2) 3/8" X 5" KWIK BOLTS I (TYP) CV -8" / / N FOW 0-11.5) 0 (b o_ 6 G Di co aci co 0 0. J� oOoJQ e>t4 RED RED RED RED RED RED RED g1 5 s:\ •, •/ ZA r i.K _8" DI CL 52 U.G. mm mismi (BY OTHERS) VIC FLANGE , NOTE: FLOOR DRAIN & PIPING SIZE MUST BE CAPABLE OF DISCHARGING ALL OF THE WATER FROM A FULL FLOW TEST AND/OR DRAINING OF THE FIRE SPRINKLER SYSTEM SYMBOL LEGEND QUALITY CONTROL BY: DATE: REVISIONS BOD CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO. DATE BY REASON FOR REVISION APPROVED FOR FABRICATION 1 11/30/01 BC REVISIONS PER CITY OF TUKWILA: ADD STANDPIPE IN EACH STAIRWELL. AREA BY DATE CONTRACT WITH CONSTRUCTION ASSOCIATES P.O. BOX 975 LYNNWOOD, WA. 98046-0975 PROJECT MANAGER : MARK GARRIBO PHONE : (425) 774-3821 SUPERINTENDENT : PHONE : tons. Inc. s4,1 Michael Brauhn 39 11 .171 CERTIFICATE OF COMPETANCY STAMP or2 ct g 0 1 CONC. I.F.O. STAIR #1 SECTION 'A' (FACING EAST) 0 2 4 WATER TIGHT SEAL AROUND U.G. PIPING PASSING THROUGH WA (BY OTHERS) KEY PLAN rs. SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 98424 CONTR. REG. NO. SMITHFS1360T SOUTHCENTER STORAGE 5950 SOUTHCENTER BLVD. TUKVVILA, WASHINGTON DESIGNER DATE SHEET B. COLLINS 10/3/01 2 OF JOB NO. T2-229 3'-11" 1'-5" z 2 z 1 ' 2 2 41-0 8-9 /0-11 8-9 �1 NOTE: — ROTATE MAIN UP ui / TO UNE ELEVATION (22) 4' 96. 'LLs BACK TO BACK 2 1-31 BLUE 2" 221/2° ELL WITH FLEX COUPLINGS 2 2 2" 221 E FLE)(, CO 8-0 WITH LINGS SEE PIPING DETAIL HIS SHEET 2 2 2 2 2 5-5 I 8-7 1-5 1 8-0 4-0 Z T 2 40 82 (GOE/CTS) 11 7-2 13 BOD 2-1 5-7 8-5 1-7 9-8 5-7 8-5 1-7 9-8 1-7 8-5 3-7 6-5 8-2 (GOE/CTS) BOD 'IFF 2-1 ! 5-7 6-5 3-7 8-5 0-9 6-11 5-11 1-7 10-0 0-5 9-7 2-5 LT. BLUE BLUE 2 2-1 1 5-7 6-5 3-7 8-5 0-9 6-11 5-11 1-7 10-0 0-5 9-7 2-5 6-11 0-9 10-0 1-3 8-9 3-3 11/2 /10 7-2 5-7 6-5 3-7 8-5 5-11 1-7 10-0 0-5 9-7 2-5 6-11 0-9 10-0 1-3 8-9 3-3 LT. BLUE STAIR #1 5-7 6-5 3-7 8-5 0-9 4-10 5-11 1-7 10-0 0-5 9-7 2-5 4-10 0-9 1' /10 7-2 LT. BLUE N BOD (102 �/ Atak 13/ " 8AFF - Q FLOOR CONTROL - ISER r/ CL SUPPLY RISER-,, (@ GRIDUNE'K') -1-- a6/ 1- 15 To II 1-0 0-9 4-10 �2\ as BLUE 1' p 11/2 ( 9-0 3-0 SEE ELEVATOR PIPING 11/2 / DETAIL THIS SHEET 0-10 iI 4-10 0-9 10-0 1-3 8-9 3-3 LT. BLUE i i i i i / i / / / i / / / / / / / / / / / / i / / i / i / 7 i / // rn lo 0 1- z io 0 m SEE RISER DETAIL SECTIONS ONSHT2OF9 7-0 PINK 42 N 4-10 0-9 2 2 2 2 f -Q---H • 10-0 1-3 8-9 3-3 ELEV #2 5'-5" / / / / / / / / / / ATIMITRTAININFZWAIAMMITilMITAMI LT. BLUE 9'-2" 4-10 0-9 10-0 1-3 8-9 3-3 2 2 0 / IL 8-0 4-0 N O) N LT. BLUE 2" 221 ELL WITH , FLEX COUPLINGS LT. BLUE WALL SCHEDULE ////////////////////1/// TYPICAL FULL HEIGHT WALL BASEMENT LEVEL 2 0 6 12 - - - - - - - OMNI - MIN- SCALE 3/16"=1'-0" HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS N �I. z 2 c0' 7" 1 // 4'-9" / 5'-4" STAIR #2 9'-10" SEE PLAN FOR PIPE LENGTHS (FITTER TO ADJUST AS NECESSARY TO FIT) SYMBOL LEGEND QUALITY CONTROL BY: DATE: REVISIONS HD SEE 'HD' HANGER DETAIL ON SHEET 8 OF 8 SYM 0 MANUFACTURER TYPE MODEL RELIABLE PENDENT G4QR HEAD FINISH ESCUTCHEON FINISH ORIFICE SIZE THREAD SIZE TEMP RATING QUANTITY BRONZE ®®®165° 48 0 RELIABLE UPRIGHT F1FR BRONZE ®®155°® RELIABLE VERT - SW F1FR BRONZE N®® 0' TOTAL THIS CONTRACT. ( 1,003 ) TOTAL THIS SHEET 187 AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO SPRINKLERS UNLESS NOTED OTHERWISE BOD CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING APPROVED FOR FABRICATION NO 1 DATE 11/30/01 BY BC REASON FOR REVISION REVISIONS PER CITY OF TUKWILA: ADD STANDPIPE IN EACH STAIRWELL. AREA BY DATE CONTRACT WITH CONSTRUCTION ASSOCIATES P.O. BOX 975 LYNNWOOD, WA. 98046-0975 PROJECT MANAGER : MARK GARRIBO PHONE : (425) 774-3821 FAX : (425) 774-9065 SUPERINTENDENT: PHONE : FAX : CERTIFICATE OF COMPETANCY STAMP 2 45° ELL 2 -c 25° / STANDARD GRVD COUPUNGS (2) PLACES / 2"GRVD TEE 2 FLEXIBLE GRVD COUPLING BENT PIPE TO BE SCH 10. PIPING DETAIL NTS FITTER /LISTER NOTES 1. INSTALL FLEXIBLE COUPLINGS @ THE TOP OF ALL RISERS 2. ALL BRANCHLINES TO BE INSTALLED @ 5 BOD, (8-11,AFF) - UNO. 3. ALL MAIN HANGERS TO BE TYPE' HD' - UNO 4. ALL BRANCHLINE HANGERS TO BE TYPE' HD' - UNO 5. ALL DROPS ARE 1 X 1-6 TXP -UNO 6. ALL BENT PIPE TO BE SCH. 10. 7. ATR LENGTHS FOR BRANCHLINES (5" BOD) TO BE AS FOLLOWS: 2" = 3/8" X 3.5" 1.5" = 3/8" X 4" 1.25" = 3/8" X 4" 1" = 3/8" X 4.5" 8. TOP OF NON-STRUCTURAL PARTITION WALLS @ 8'-0" AFF. 9. STANDPIPE TO BE INSTALLED AT 3.5" BOD TYPICAL. 10. STANDPIPE HANGERS TO BE TYPE "S" W/ 3/8" x 6" ATR TYPICAL. KEY PLAN F. SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 98424 CONTR REG. NO. SMITHFS1360T Bus' ( 253) 926 - 1880 FAX: ( 253) 926 - 2350 SOUTHCENTER STORAGE 5950 SOUTHCENTER BLVD. TUKWILA, WASHINGTON DESIGNER DATE SHEET JOB NO. B. COLLINS 10/3/01 3 OF • T2-229 5'-4" 4'-6" 5'-4" 11.81\11 31.8 11-0" 5'-0" 10'-0" 23'-4" 7'-10" 210 15'-4" 11,-10" (216) 2" 221/22 ELL WITH - FLEX. COUPLINGS •2 5'-0" 51-4" \'-8"\ 3'-8" 2'-10" 4'-10" 12'-0" 91-0" 12-0" 111-0" 2'-10" 5'-4" 4'-10" 1'-8"\ 3'-8" 5'-0" 15'-4" 9'-0" 111-0" 23'-4" 9'-8" 1'-0" 5'-4" 51-0" \1'-8" 3'-8" 4'-4" 9'-10" 6-0 2-4 7-8 4-4 5-8 .2 2" 221/22 ELL WITH FLEX. COUPLINGS • 9-0 SEE PIPING DETAIL THIS SHEET O #322 5'-6" 208 4 #408 2" 90° & 2" 221/2 ELL BACK TO BACK WITH / FLEX. COUPLINGS 2-3 #353 60 / O #321 / 0 #337 O #393 N O #320 STAIR #1 AIL • ' D AIL N r O N T O N N . r - .1 (V N r r O r 1-10 CODD =_-. N r r O / N / — r r O — N • / N r r r 1 N — r r r O / —O 1 -1 00 CO REVISIONS PER CITY OF TUKWILA: ADD STANDPIPE IN EACH STAIRWELL. BOD #326 1-0 159 a• #359 #325 #349 #358 N INMAN IN I /41 IN NM N IN N FA IS BOD Q MAIN GREEN Q FLOOR CO 3-7 s-10-23 / /5-1 340 4-1 7—//7-2 / /„� (9 1 1-6 16 0 #317 PINK N Ln r) O #389 Q SUPPLY RISER - (@GRIDLINE 'K' ) TOILET 01 MPANINNIKAIMINUNNINL%MINNK�A -, ELECTRICAL OFFICE/SALES ELEV #1 O #388 ELEV #2 SEE RISER DETAIL SECTIONS ON SHT 2OF 9 9'-2" J 0- d el GREEN GREEN GREEN GREEN GREEN 8" 4" 90° & 4" 221/2° ELL BACK TO BACK WITH FLEX. COUPLINGS — #331 LOBBY N 139 . #339 O #387 1 17,9 #379 .1 #345 WALL SCHEDULE / / / / / / / / / / / / / / / / / / / / / / / / / TYPICAL FULL HEIGHT WALL GRFEN 4" TEE & 2" 221/2° ELL BACK TO BACK WITH FLEX. COUPLINGS - (TYPICAL (5) PLCS) C9 N O #386 N BASEMENT LEVEL 1 CD 0 6 12 - - - - — — - — — — — SCALE 3/16"=1'-0" HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SEE 'HD' HANGER DETAIL ON SHEET 8 OF 8 SYM MANUFACTURER TYPE MODEL HEAD FINISH ESCUTCHEON FINISH ORIFICE SIZE THREAD SIZE TEMP. RATING QUANTITY • RELIABLE PENDENT G4QR BRONZE WHITE 1/2" 1/2" 165° 61 O RELIABLE UPRIGHT F1 FR BRONZE N/A 1/2' 1/2" 155° 123 TOTAL THIS CONTRACT: ( 1,003 ) TOTAL THIS SHEET: 184 AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE F r, a / 341 92 1 7,17 /, 6-4 r2-'1`1z7Q1 1" 9 28 29 // #312 HYDRAULICALLY MOST DEMANDING AREA: 2" 221/2° ELL WITH FLEX. COUPLINGS STAIR #2 ANDPIP DENSITY: .15 GPM OVER 5,000 SQUARE FEET SYSTEM DEMAND AT BOR: 1,217.63 GPM AT 52.93 PSI ( INCLUDING 100 GPM FOR INSIDE HOSE STREAMS ) SYMBOL LEGEND QUALITY CONTROL BY: DATE: REVISIONS CONTRACT WITH CONSTRUCTION ASSOCIATES S��T CENTERLINE OF PIPE TO REFERENCED NO. DATE BY REASON FOR REVISION m STRUCTURE IN INCHES APPROVED FOR FABRICATION 1 11/30/01 BC REVISIONS PER CITY OF TUKWILA: ADD STANDPIPE IN EACH STAIRWELL. BOD AREA BY DATE S`15�em `�c to Certifies 9,i, 2 -WAY EARTHQUAKE SWAY BRACE P.O. BOX 975 r o`o, hF ,'♦�. ��� a°ro!,o a '� NUMBER INDICATES TYPE LYNNWOOD, WA. 98046-0975 �� / 399 -6071 ' 2R►'•" iWJ ,L 4 -WAY EARTHQUAKE SWAY BRACE �� NUMBER INDICATES TYPE PROJECT MANAGER : MARK GARRIBO J. 'n - Fy °o Fd`14, (tw°nSnKK`s 0,- tbt°„ �-- HANGER LOCATION - — ----0' ELEVATION ABOVE REFERENCED POINT IN FEET AND PHONE : (425) 774-3821 FAX : (425) 774-9065 SUPERINTENDENT : PHONE : FAX bz 8a Dece� CERTIFICATE OF COMPETANCY STAMP INCHES O HYDRAULIC CALCULATION NODE I{i FLEXIBLE COUPLING II RIGID COUPLING 2" GRVD TEE FLEXIBLE GRVD COUPLINGS - (4) PLACES 2" GRVD 221/° ELL SEE PLAN FOR PIPE LENGTHS (FITTER TO ADJUST AS NECESSARY TO FIT) PIPING DETAIL N.T.S. FITTER /LISTER NOTES 1. INSTALL FLEXIBLE COUPLINGS @ THE TOP OF ALL RISERS 2. ALL MAINS THIS SHEET TO BE INSTALLED @ 5 BOD (8-7 AFF) - UNO 3. ALL BRANCHLINES TO BE INSTALLED @ 5 BOD - UNO 4. ALL MAIN HANGERS TO BE TYPE' HD ' - UNO 5. ALL BRANCHLINE HANGERS TO BE TYPE' HD ' - UNO 6. ALL DROPS ARE 1 X 1-0 T X P- UNO 7. ATR LENGTHS FOR BRANCHLINES (5" BOD) TO BE AS FOLLOWS: 4" = 3/8" X 2.5" 2" = 3/8" X 3.5" 1.5" = 3/8" X 4" 1.25" = 3/8" X 4" 1" = 3/8" X 4.5" 8. TOP OF NON-STRUCTURAL PARTITION WALLS @ 8'-0" AFF. KEY PLAN SMITH FIRE SYSTEMS, INC. ir 1106 54th AVE EAST TACOMA WA 98424 CONTR. REG. NO. SMITHFS1360T Bus: ( 253) 926 - 1880 FAX: ( 253) 926 - 2350 SOUTHCENTER STORAGE 5950 SOUTHCENTER BLVD. TUKWILA, WASHINGTON DESIGNER DATE SHEET B. COLLINS 10/3/01 OF 9)� n JOB NO. T2-229 b b 0 b Zoto 0 b 0 b 9, b b / co b b 0 / 9, V 0 CV/ kv;-/ c 3'-11" 1'-5" 2 2 ty1 0'-7" 0—/ 1 +0 8-5 / 1-3 9-1.5 0 NOTE: AFF 2 FF' -0 1-31 ORANGE 2 .2 tt—'0 1-3 6-2 2" 22W ELL WITH (.---- FLEX. COUPLINGS 2 •2 ROTATE MAIN UP TO UNE ELEVATION BACK TO BACK 8-7 5-11 SEE PIPING DETAIL THIS SHEET 5-11 2-1 ORANGE 7-5 (GOE/CTS) 2 .2 .2 0 IF 0 6-0 2-1 3-11 ORANGE 2-1 3-11 co 6-0 2-1 3-11 2 / 1120 7-1 0-11 7-10 SGOE CTS1 14 ORANGE .2 .2 .2 .2 2-1 / 3-11 6-0 2-1 3-11 7-0 2 0 7-6 3-7 BOD DR ORANGE 2-1 YELLOW 3-11 7-0 7-6 3-7 7-0 3-1 2-11 6-0 11/2 /10 7-2 3-11 6-0 2-1 3-11 7-0 7-0 3-1 2-11 YELLOW STAIR #1 TECH -FAST TO OFFSE MEyBEgs ORANGE 3-11 6-0 2-1 3-11 7-0 7-0 3-1 2-11 11/2 /10 7-2 RISER DETAIL ORANGE YELLOW BOD 1.5 1-0 2-1 5-11 4-11 3-11 2-1 • .11/2 /10 7-2 c_ FLOOR CO ROL RISER SUPPLY RI ORANGE SE PIPING DETAIL 6.7 THIS SHEET 2. 2-7 (GOE/CTS) YELLOW oco 4, SEE RISER DETAIL 1 ON 2 FOR CONTINUATION ceez 0 cn 3-11 2-1 ELEV #1 cn W12 BEAM YELLOW 3-11 2-1 DRY SIDEWALL TYP. - (4) PLCS. NOTE: N.A.S. ABOVE EXTERIOR ENTRY CANOPY CEIUNG (NONCOMBUSTIBLE VOID SPACE) WALL SCHEDULE TYPICAL FULL HEIGHT WALL 0 -}.•<° e<,/=4, EXTERIOR ENTRY CANOPY FLOOR LEVEL N. FIRST FLOOR 6 SEM SEM IMM MM MM HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS YELLOW 4-11 6-0 1-1 4-11 YELLOW 3-11 6-1 2" 221/2° ELL WITH FLEX. COUPLINGS STAIR #2 SEE PLAN FOR PIPE LENGTHS (- STANDARD GRVD COUPLINGS (2) PLACES 2" GRVD TEE (FITTER TO ADJUST AS NECESSARY TO FIT) SYMBOL LEGEND QUALITY CONTROL BY: DATE: REVISIONS DR SEE 'DR' HANGER DETAIL ON SHEET 8 OF 8 KB SEE 'KB' HANGER DETAIL ON SHEET 8 OF 8 SYM • 0 MANUFACTURER RELIABLE TYPE PENDENT MODEL HEAD FINISH G4QR BRONZE ESCUTCHEON FINISH WHITE ORFICE SIM 1/2" THREAD SIZE 1/2" RATING 165° QUANTITY 69 RELIABLE RELIABLE UPRIGHT BRONZE N/A 1/2' 1/2" 139 G3FR CHROME CHROME 1/2" 4 TOTAL THIS CONTRACT: ( TOTAL T HIS SI -IE ET: 212 AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUR FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE BOD CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO. DATE BY REASON FOR REVISION APPROVED FOR FABRICATION 1 11/30/01 BC REVISIONS PER CITY OF TUKWILA: ADD STANDPIPE IN EACH STAIRWELL. AREA BY DATE CONTRACT WITH CONSTRUCTION ASSOCIATES P.O. BOX 975 LYNNWOOD, WA. 98046-0975 PROJECT MANAGER . MARK GARRIBO PHONE : (425) 774-3821 SUPERINTENDENT : PHONE : CERTIFICATE OF COMPETANCY STAMP 45° ELL FLEXIBLE GRVD COUPLING BENT PIPE TO BE SCH 10. PIPING DETAIL N.T.S. FITTER / LISTER NOTES 1. INSTALL FLEXIBLE COUPLINGS @ THE TOP OF ALL RISERS 2. ALL BRANCHLINES TO BE INSTALLED @ 5 BOD (9-1.5 AFF) - UNO 6. ATR LENGTHS FOR BRANCHLINES (5" BOD) TO BE AS FOLLOWS: 4" = 3/8" X 3" 2" = 3/8" X 4" 1" = 3/8" X 5" 7. TOP OF NON-STRUCTURAL PARTITION WALLS @ 8'-0" AFF. 8. ALL BENT PIPE TO BE SCH. 10. KEY PLAN f SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 98424 CONTR. REG. NO. SMITHFS1360T SOUTHCENTER STORAGE 5950 SOUTHCENTER BLVD. TUKWILA, WASHINGTON DESIGNER DATE SHEET JOB NO. B. COLLINS 10/3/01 5 OF 9 2" 221 ELL WITH FLEX. COUPLINGS r .2 .2 +O / 1-3 8-9 NOTE: ROTATE MAIN UP TO LINE ELEVATION .2 +HO 1-31 BROWN ' 221/22 ELL WITH 0 0 0 0 b b 0 b 0 b b O I 1 0 L) C v 'v L co v / / / / BACK TO BACK UPLINGS BROWN 3y SEE PIPING DETAIL THIS SHEET 2 211 2 6-0 2-1 3-11 2 07/ 2 4-5 6-0 BROWN 2-1 1 3-11 2-1 3-11 BROWN 2-1 3-11 TqN .11/2 / .2 .2 .2 .2 2-1 3-11 2 •/2 11 .2 0 .2 1411 7-0 3-1 2-11 6-0 .1'/2 01 / 6-2 2-1 3-11 2 .2 .2 .2 2 • • 0---/ 7-0 3-1 2-11 6-0 3-11 BROWN RISER DETAIL CO 1 2-1 AIN -BOD 6-0 2-1 3-11 2 .2 .2 • / II 0 7-0 3-1 2-11 1Y /1I0 7-2 BROWN .2 .2 0/ 7-8 2-3 3-11 2-1 0 b 0 b 0 0 ► ► AFF Q FLOOR CONTROL RISER -� Q SUPPLY RISER--� (@GRIDLINE 'K ) 2-7 (GOE/CTS) 0 0 0 T 0 0 0 b 0 b b / b 0 co / 1 In 0 v BOD ELEV #2 SEE RISER DETAIL ON SHT2OF9 ELEV #1 ✓Lf.�afA%�� 9'-2" c-� W12 BEAM 3-11 2-1 m CV 0 0 0 4 b t� • 3-11 6-0 •2 i 9-11. • .6 4-11 6-0 1-1 4-11 WALL SCHEDULE -//////////////////7////,/ TYPICAL FULL HEIGHT WALL N 2" 221/2° ELLWITH FLEX. COUPLINGS STAIR #2 SECOND FLOOR ED 0 6 12 O N IMO SCALE 3/16"=1'-0" HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS z 7"1 4'-9" 5,-4" 9'-10" 1) / / SEE PLAN FOR PIPE LENGTHS SYMBOL LEGEND QUALITY CONTROL BY: DATE: REVISIONS DR SEE 'DR' HANGER DETAIL ON SHEET 8 OF 8 SYM • MANUFACTURER RELIABLE TYPE PENDENT MODEL HEAD FINISH G4QR BRONZE ESCUTCHEON FINISH WHITE ORIFICE SIZE 1/2" THREAD SIZE 1/2" TEMP. RATING 165° QUANTITY 72 KB SEE 'KB' HANGER DETAIL ON SHEET 8 OF 8 O RELIABLE UPRIGHT F1 FR BRONZE N/A 1/2' 1/2" 155° 138 TOTAL THIS CONTRACT: ( 1,003 ) TOTAL THIS SHEET: 210 AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE BOD �r -f- CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO. DATE BY REASON FOR REVISION APPROVED FOR FABRICATION 1 11/30/01 BC REVISIONS PER CITY OF TUKWILA: ADD STANDPIPE IN EACH STAIRWELL. AREA BY DATE MEM CONTRACT WITH CONSTRUCTION ASSOCIATES P.O. BOX 975 LYN N WOO D, WA. 98046-0975 PROJECT MANAGER : MARK GARRIBO PHONE : (425) 774-3821 FAX : (425) 774-9065 SUPERINTENDENT : PHONE: FAX : CERTIFICATE OF COMPETANCY STAMP (FITTER TO ADJUST AS NECESSARY TO FIT) •2 45° ELL 2 STANDARD GRVD COUPLINGS (2) PLACES / 2" GRVD TEE 25° .2 FLEXIBLE GRVD COUPLING BENT PIPE TO BE SCH 10. PIPING DETAIL N.T.S. FITTER /LISTER NOTES 1. INSTALL FLEXIBLE COUPLINGS @ THE TOP OF ALL RISERS 2. ALL BRANCHLINES TO BE INSTALLED @ 5 BOD (9-1.5 AFF) - UNO 3. ALL MAIN HANGERS TO BE TYPE' KB' - UNO 4. ALL BRANCHLINE HANGERS TO BE TYPE' DR' - UNO 5. ALL DROPS ARE 1 X 1-6 T X P- UNO 6. ATR LENGTHS FOR BRANCHLINES (5" BOD) TO BE AS FOLLOWS: 4" = 3/8" X 3" 2" = 3/8" X 4" 1.5" = 3/8" X 4.5" 1.25" = 3/8" X 4.5" 1" = 3/8" X 5" 7. TOP OF NON-STRUCTURAL PARTITION WALLS @ 8'-0" AFF. 8. ALL BENT PIPE TO BE SCH. 10. KEY PLAN SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 98424 CONTR. REG. NO. SMITHFS1360T Bus: ( 253) 926 - 1880 FAX: ( 253) 926 - 2350 SOUTHCENTER STORAGE 5950 SOUTHCENTER BLVD. TUKWILA, WASHINGTON DESIGNER DATE SHEET JOB NO. B. COLLINS 10/3/01 T2-229 .1'/2 al 7-2 G ti A Hc l) O .11/2 91I / 7-2 4 8AF-5.5 F BOD 1'/2 al/ 7-2 1'/z O-/ 7-2 1'/2 O/ 7-2 , UPLINGS BROWN 3y SEE PIPING DETAIL THIS SHEET 2 211 2 6-0 2-1 3-11 2 07/ 2 4-5 6-0 BROWN 2-1 1 3-11 2-1 3-11 BROWN 2-1 3-11 TqN .11/2 / .2 .2 .2 .2 2-1 3-11 2 •/2 11 .2 0 .2 1411 7-0 3-1 2-11 6-0 .1'/2 01 / 6-2 2-1 3-11 2 .2 .2 .2 2 • • 0---/ 7-0 3-1 2-11 6-0 3-11 BROWN RISER DETAIL CO 1 2-1 AIN -BOD 6-0 2-1 3-11 2 .2 .2 • / II 0 7-0 3-1 2-11 1Y /1I0 7-2 BROWN .2 .2 0/ 7-8 2-3 3-11 2-1 0 b 0 b 0 0 ► ► AFF Q FLOOR CONTROL RISER -� Q SUPPLY RISER--� (@GRIDLINE 'K ) 2-7 (GOE/CTS) 0 0 0 T 0 0 0 b 0 b b / b 0 co / 1 In 0 v BOD ELEV #2 SEE RISER DETAIL ON SHT2OF9 ELEV #1 ✓Lf.�afA%�� 9'-2" c-� W12 BEAM 3-11 2-1 m CV 0 0 0 4 b t� • 3-11 6-0 •2 i 9-11. • .6 4-11 6-0 1-1 4-11 WALL SCHEDULE -//////////////////7////,/ TYPICAL FULL HEIGHT WALL N 2" 221/2° ELLWITH FLEX. COUPLINGS STAIR #2 SECOND FLOOR ED 0 6 12 O N IMO SCALE 3/16"=1'-0" HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS z 7"1 4'-9" 5,-4" 9'-10" 1) / / SEE PLAN FOR PIPE LENGTHS SYMBOL LEGEND QUALITY CONTROL BY: DATE: REVISIONS DR SEE 'DR' HANGER DETAIL ON SHEET 8 OF 8 SYM • MANUFACTURER RELIABLE TYPE PENDENT MODEL HEAD FINISH G4QR BRONZE ESCUTCHEON FINISH WHITE ORIFICE SIZE 1/2" THREAD SIZE 1/2" TEMP. RATING 165° QUANTITY 72 KB SEE 'KB' HANGER DETAIL ON SHEET 8 OF 8 O RELIABLE UPRIGHT F1 FR BRONZE N/A 1/2' 1/2" 155° 138 TOTAL THIS CONTRACT: ( 1,003 ) TOTAL THIS SHEET: 210 AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE BOD �r -f- CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO. DATE BY REASON FOR REVISION APPROVED FOR FABRICATION 1 11/30/01 BC REVISIONS PER CITY OF TUKWILA: ADD STANDPIPE IN EACH STAIRWELL. AREA BY DATE MEM CONTRACT WITH CONSTRUCTION ASSOCIATES P.O. BOX 975 LYN N WOO D, WA. 98046-0975 PROJECT MANAGER : MARK GARRIBO PHONE : (425) 774-3821 FAX : (425) 774-9065 SUPERINTENDENT : PHONE: FAX : CERTIFICATE OF COMPETANCY STAMP (FITTER TO ADJUST AS NECESSARY TO FIT) •2 45° ELL 2 STANDARD GRVD COUPLINGS (2) PLACES / 2" GRVD TEE 25° .2 FLEXIBLE GRVD COUPLING BENT PIPE TO BE SCH 10. PIPING DETAIL N.T.S. FITTER /LISTER NOTES 1. INSTALL FLEXIBLE COUPLINGS @ THE TOP OF ALL RISERS 2. ALL BRANCHLINES TO BE INSTALLED @ 5 BOD (9-1.5 AFF) - UNO 3. ALL MAIN HANGERS TO BE TYPE' KB' - UNO 4. ALL BRANCHLINE HANGERS TO BE TYPE' DR' - UNO 5. ALL DROPS ARE 1 X 1-6 T X P- UNO 6. ATR LENGTHS FOR BRANCHLINES (5" BOD) TO BE AS FOLLOWS: 4" = 3/8" X 3" 2" = 3/8" X 4" 1.5" = 3/8" X 4.5" 1.25" = 3/8" X 4.5" 1" = 3/8" X 5" 7. TOP OF NON-STRUCTURAL PARTITION WALLS @ 8'-0" AFF. 8. ALL BENT PIPE TO BE SCH. 10. KEY PLAN SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 98424 CONTR. REG. NO. SMITHFS1360T Bus: ( 253) 926 - 1880 FAX: ( 253) 926 - 2350 SOUTHCENTER STORAGE 5950 SOUTHCENTER BLVD. TUKWILA, WASHINGTON DESIGNER DATE SHEET JOB NO. B. COLLINS 10/3/01 T2-229 3'-11" 1'-5" Z 2 2 PT1 • -9 NOTE: #831 2 .2 .2 .2 .2 2" 221/2° ELL WITH (..._ FLEX. COUPLINGS 2 #832 •3-1 8-3 1-9 8-3 1-9 5-8 ® GOLD ROTATE MAIN UP TO UNE ELEVATION 2 1/0 623 • 2 T#823 5-11 2-1 #821 SEE PIPING DETAIL IS SHEET 7-2 2-1 1= 3-11 2-1 3-11 7-6 / 617 2-1 / #817.0 N 606 #806 627 #827 2-1 3-11 #842 •2 4-11 #812 2 630 #830 / / / / / / / / / / / / / 2-1 3-11 .2 /II .2 5-7 4-5 587 #787 SIO 4 SILVER 2 / .2 3-7 6-5 .2 .2 .2 .2 .2 7-0 3-1 2-11 6-0 #790 #791 ��imsrr►.�rrar►rr 2 1 iz )I' /' li 0 / 0 2-1 3-11 PT4 ii .2 .2 2 1 .11/: 2-1 3-11 -11 576 #776 TI 6-0 #778 3-11 2-1 #779 . 1 1 SILVER STAIR #1 7- 2-1 MAIN -BOP N I! 2 O/ 2 0 211 2 3-11 w 6-0 2-1 3-11 2 .2 //II 5-7 4-5 2/.2 II 2 0 2 / O 2. 7-0 3-1 2-11 6-0 3-11 #764 #765 #766 SILVER / / / / / / / / /Z / / / / / / / / / / / / / / / / CV M V BOP r/ / 541 . 2 #741 AFF I U PT1 4-1 Q FLOOR CONTROL RISER Q SUPPLY RISER - (@ GRIDLINE 'K' ) • 2 6s / GOLD 7-6 2-5 7-7 4-5 S E PIPING DETAIL THSHEET� 2. 2-7 (GOE/CTS) / 3-1 / PT5 .2 .2 .2 • 3-11 2-1 6-0 #752 SILVER w 0) co 0 cnz ED #719 .2 5-5 2 #720 .2 2-7 0 1. 0-6 521 #721 N SEE RISER DETAIL ON SHT2OF9 #701 •? ELEV #2 534 #734 .11/2 .11/2 2-11 2-1 w Flo V N 533 / / / / / / / / / / / / / / / / 510 #710 #733 .1 .1 • 2-11 2-1 7-0 #738 2-1 6-0 #739 SILVER 9'-2" PLUM •2 8-1 #730 3-11 2-1 6-0 #731 3-11 #732 ('wALLSCHEDULE ////////// /7////// / / / /I TYPICAL FULL HEIGHT WALL TYPICAL FULL HEIGHT WALL HYDRAULICALLY MOST DEMANDING AREA: DENSITY: .15 GPM OVER 5,000 SQUARE FEET SYSTEM DEMAND AT BOR: 1,281.35 GPM AT 51.57 PSI ( INCLUDING 100 GPM FOR INSIDE HOSE STREAMS ) THIRD FLOOR 0 6 12 SCALE 3/16"=1'-0" HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS • 3-1 522 #722, • 6-0 523 #723 2-1 524 #724 2" 221/2° ELL WITH 504 . : yrI /a► 1 i647 . #847 -01.1°2) . 11 .1'/2 2 '7 2-1 N PT5 i 7-2 1-0 Cr) 646 f I j #846 J v ob cPT2 3 .11/2 .11/2 1 • 9-3 1-0 #845 SILVER SILVER STAIR #2 (<<,</ az 7"1 4,-9" 5'-4" / 9'-10" 0 Zb 0 0 0 / b C -v / b c9 rct 1 0 0 c9 b SEE PLAN FOR PIPE LENGTHS (FITTER TO ADJUST AS NECESSARY TO FIT) SYMBOL LEGEND QUALITY CONTROL BY: DATE: REVISIONS SEE 'PT' HANGER DETAIL ON SHEET 8 OF 8 SEE 'SB' HANGER DETAIL ON SHEET 8 OF 8 SYM • 0 MANUFACTURER RELIABLE TYPE PENDENT MODEL HEAD FINISH ESCUTCHEON FINISH ORIFICE SIE THREAD SIZE TEMP. RATING QUANTITY G4QR BRONZE WHITE 1/2" 1/2" 165° 72 RELIABLE UPRIGHT F1 FR BRONZE N/A 1/2' 1/2" 155° 138 TOTAL THIS CONTRACT: 1,003) TOTAL THIS SHE ET: 210 AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURUN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE BOD CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO. DATE BY REASON FOR REVISION APPROVED FOR FABRICATION 1 11/30/01 BC REVISIONS PER CITY OF TUKWILA: ADD STANDPIPE IN EACH STAIRWELL. AREA BY DATE CONTRACT WITH CONSTRUCTION ASSOCIATES P.O. BOX 975 LYN N WOO D, WA. 98046-0975 PROJECT MANAGER : MARK GARRIBO PHONE : (425) 774-3821 FAX : (425) 774-9065 SUPERINTENDENT: PHONE: FAX : CERTIFICATE OF COMPETANCY STAMP •2 45° ELL .2 25° / STANDARD GRVD COUPLINGS (2) PLACES I 2"GRVD TEE •2 FLEXIBLE GRVD COUPLING BENT PIPE TO BE SCH 10. PIPING DETAIL N.T.S. FITTER /LISTER NOTES 1. INSTALL FLEXIBLE COUPLINGS @ THE TOP OF ALL RISERS 2. ALL BRANCHLINES AT THE ROOF TO BE INSTALLED PARALLEL TO THE ROOF @ 6" BOP - UNO. 3. ALL MAIN HANGERS TO BE TYPE ' PT' - UNO 4. ALL BRANCHLINE HANGERS TO BE TYPE ' SB' - UNO 5. ALL DROPS ARE 1 X 1-6 T X P- UNO 6. ATR LENGTHS FOR BRANCHLINES (6" BOP) TO BE AS FOLLOWS: 2" = 3/8" X 9" 1.5" = 3/8" X 9.5" 1.25" = 3/8" X 9.5" 1" = 3/8" X 10" 7. TOP OF NON-STRUCTURAL PARTITION WALLS @ 8'-0" AFF. 8. ALL BENT PIPE TO BE SCH 10. KEY PLAN SMITH FIRE SYSTEMS, INC. ir S 1106 54th AVE EAST TACOMA, WA 98424 CONTR. REG. NO. SMITHFS1360T Bus: ( 253) 926 - 1880 FAX: ( 253) 926 - 2350 SOUTHCENTER STORAGE 5950 SOUTHCENTER BLVD. TUKWILA, WASHINGTON DESIGNER DATE SHEET JOB NO. B. COLLINS 10/3/01 7 OF 9 T2-229 TOLCO FIG 4A PIPE CLAMP TOLCO FIGURE 980 UNIVERSAL SWIVEL SWAY BRACE ATTACHMENT 1/2" X 3 3/4" KWIK BOLT W/ 1/2" NUT (2 1/2" MIN EMBED) 1/2" X 3 3/4" KWIK BOLT W/ 1/2" NUT (2 1/2" MIN EMBED) TOLCO FIG. 980 SWAY BRACE ATTACHMENT TOLCO FIGURE 4A PIPE CLAMP WITH TOLCO FIGURE 980 SWIVEL SWAY BRACE ATTACHMENT J 52° ANGLE FROM VERTICAL (EACH BRACE) CONC. DECK TOLCO FIG. 980 SWAY BRACE ATTACHMENT TOLCO FIG. 907 4 WAY ATTACHMENT E.Q. BRACE #1 (FOUR WAY) 4C STEEL COLUMN SPRINKLER MAIN 75° ANGLE FROM VERTICAL 1" SCH 40 PIPE TOLCO FIGURE 980 UNIVERSAL SWIVEL SWAY BRACE ATTACHMENT ATTACH TO COLUMN W/ 1/2" X 3" THRU-BOLT W/ 1/2" NUT & WASHER 2" X 4" X 12" WOOD HEADER N.T.S. ATTACH TO COLUMN W/ (2) 3/8" X 3" THRU-BOLTS W/ 3/8" NUTS & WASHERS E.Q. BRACE #5 (LONGITUDINAL) N.T.S. 6'-0" 6" FIELD VERIFY FIELD VERIFY L 6" METAL ROOF/DECK SIDE BEAM BRACKET ATR BOLT, NUT & WASHER RING HANGER Z-PURUN 11111 — CENTERLINE OF PURUN 3/8" X 9" LONG ROD ATR WELDED TO EA. END @ OPPOSING DIRECTIONS HANGER RING TRAPEZE PIPE (FOR SIZE & SCH. SEE TABLE BELOW) PIPE TO BE SUPPORTED (FOR SIZE AND SCH. SEE TABLE BELOW) HANGER TYPE PIPE TO BE SUPPORTED SPAN BETWEEN JOISTS TRAPEZE PIPE SIZE NUT, BOLT & WASHER SIZE SIDE BEAM BRACKET ATR SIZE MAXIMUM DISTANCE BETWEEN HANGERS SIZE SCH SF SCH 10 SCH 40 PT1 6" 10 5'-0" 21/2" 1/2" GRINNELL 207 1/2' 10' PT2 4" SF 5'-0" 2%2" 1/2" TOLCO 58 %' 10' PT3 2" SF 5'-0" 2" 3/8' TOLCO 58 3/8' 12' PT4 1%2" SF 5'-0" 2" 3/e" TOLCO 58 3/8" 12' PT5 1" 40 5'-0" 2" 3/8' TOLCO 58 %" 12' 'PT' HANGER DETAIL N.T.S. TOLCO FIGURE 1000 FAST CLAMP SWAY BRACE ATTACHMENT SPRINKLER MAIN 4" X 4" X 24" WOOD HEADER ATTACH TO STUDS W/ (2) 3/8" X 3" LAG SREWS W/ 3/8" NUT & WASHER (1) LAG AT EACH END OF 4" X 4" — T TOLCO FIGURE 980 UNIVERSAL SWIVEL SWAY BRACE ATTACHMENT 1" SCH 40 PIPE I 75° ANGLE FROM VERTICAL TOLCO FIGURE 980 UNIVERSAL SWIVEL SWAY BRACE ATTACHMENT STEEL STUD WALL 52° ANGLE FROM VERTICAL 52° ANGLE FROM VERTICAL 1" SCH 40 PIPE TOLCO FIG. 907 4 WAY ATTACHMENT 1" SCH 40 PIPE TOLCO FIG 1000 , x• FAST CLAMP 4/+��Q7- � 4" X 4" X 24" WOOD HEADER ATTACH TO STUDS W/ (2) 3/8" X 3" LAG SKEWS W/ 3/8" NUT & WASHER (1) LAG AT EACH END OF 4" X 4" 1/2" x 4" LAG SCREW E.Q. BRACE #2 ( FOUR WAY) 4C STEEL COLUMN ATTACH TO COLUMN W/ 1/2" X 3" THRU-BOLT W/ 1/2" NUT & WASHER 2" X 4" X 12" WOOD HEADER ATTACH TO COLUMN W/ (2) 3/8" X 3" THRU-BOLTS W/ 3/8" NUTS & WASHERS E.Q. BRACE #6 (LATERAL) N.T.S. METAL ROOF/DECK (2) 1/4" X 1" TEK SCREWS TOLCO FIGURE 58 SIDE BEAM BRACKET--�" 3/8" A.T.R. Z-PURUN — CENTERLINE OF PURUN SPRINLKER BRANCHUNE 1 'SB' HANGER DETAIL N.T.S. HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS N.T.S. GRINNELL FIGURE 261 RISER PIPE CLAMP CONC. DECK 1/2" X 3 3/4" KWIK BOLT W/ 1/2" NUT (2 1/2" MIN EMBED) . 4 52° ANGLE FROM VERTICAL TOLCO FIGURE 980 UNIVERSAL SWIVEL SWAY BRACE ATTACHMENT TOLCO FIGURE 980 UNIVERSAL SWIVEL SWAY BRACE ATTACHMENT — 1/2" X 5 1/2" KWIK BOLT W/ 2" SQUARE WASHER&1/2"NUT (2 1/2" MIN EMBED) CONC. DECK RISER CLAMP DETAIL N.T.S. METAL ROOF/DECK 1" SCH 40 PIPE TOLCO FIGURE 4A PIPE CLAMP E.Q. BRACE #3 (LONGITUDINAL) 1/2' X 1" BOLT, NUT & WASHER GRINNELL FIG. 207 SIDE BEAM BRACKET---"" 1/2" ATR —0-- 6" MAIN Z-PURUN CENTERLINE OF PURUN 'SBI' HANGER DETAIL N.T.S. N.T.S. 3/8" x 3/4" BOLT 2" SQUARE WASHER CONC. DECK 1/2" X 3 3/4" KWIK BOLT W/ 1/2" NUT (2 1/2" MIN EMBED) . 4. • 4. . 52° ANGLE d a FROM VERTICAL TOLCO FIGURE 1000 FAST CLAMP SWAY BRACE ATTACHMENT 1" SCH 40 PIPE TOLCO FIGURE 980 UNIVERSAL SWIVEL SWAY BRACE ATTACHMENT E.Q. BRACE #4 (LATERAL) 3/8" x 1 3/4" ROD COUPUNG 3/8" ATR 1" TO 4" PIPE (SEE PLAN FOR PIPE SIZES) PAN DECKING 'DR' HANGER DETAIL 1/2" X 3 3/4" KWIK BOLT (21/2" MIN EMBED) N.T.S. CONC. DECK •• • d 4- a 4 • • • 1/2" ROD COUPUNG 1/2" ATR (CTS IN THE FIELD) HANGER RING SEE PLAN FOR SIZES 'KB' HANGER DETAIL N.T.S. SYMBOL LEGEND QUALITY CONTROL BY: DATE: REVISIONS SYM MANUFACTURER TYPE MODEL HEAD FINISH ESCUTCHEON FINISH ORIFICE SIZE THREAD SIZE TEMP. RATING QUANTITY AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE BOD CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE NUMBER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO. DATE BY REASON FOR REVISION APPROVED FOR FABRICATION 1 11/30/01 BC REVISIONS PER CITY OF TUKWILA: ADD STANDPIPE IN EACH STAIRWELL. AREA BY DATE CONTRACT WITH CONSTRUCTION ASSOCIATES P.O. BOX 975 LYNNWOOD, WA. 98046-0975 PROJECT MANAGER : MARK GARRIBO PHONE : (425) 774-3821 FAX : (425) 774-9065 SUPERINTENDENT : PHONE: FAX : �ans.Ine. SM ocSs �c Certifigsc y. ., ... Sao �...' o, a heel : : uhn 391 • -6071 0 T o��''a� the -ugh Dece0 CERTIFICATE OF COMPETANCY STAMP N.T.S. BOTTOM FLANGE OF STEEL BEAM RETAINER STRAP HANGER RING 7— GRINNELL FIG. 92 UNIVERSAL TOP BEAM CLAMP 3/8" ATR (CTS IN THE FIELD) SEE PLAN FOR SIZES 'TB' HANGER DETAIL HILTI DROP-IN ANCHOR 4 N.T.S. CONC. DECK - •• • •a 3/8" ATR (CTS IN THE FIELD) HANGER RING SEE PLAN FOR SIZES 'HD' HANGER DETAIL N.T.S. POST TENSION SLAB Q V 4 4 . (2) 3/8" ATR TOLCO FIG 4 PIPE CLAMP 4 4 z (2) 3/8" HILTI HDIP DROP IN ANCHORS (2) 3/8" NUT AND WASHER 'S' HANGER DETAIL N.T.S. J KEY PLAN SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA WA 98424 CONTR. REG. NO. SMITHFS1360T Bus: ( 253) 926 -1880 FAX: ( 253) 926 - 2350 SOUTHCENTER STORAGE 5950 SOUTHCENTER BLVD. TUKWILA, WASHINGTON DESIGNER B. COLLINS DATE 10/3/01 SHEET 8 OF 9 JOB NO. T2-229 T£ POTTER ROEMER MODEL # 5876 TWO-WAY OUTLET WITH (2) #4085 FIRE HOSE VALVES 40'-0" AFF @ 11-1 3RD FLOOR 30'-0" AFF @ 2ND FLOOR AFF @ Ill 1ST FLOOR 10'-0"AFF@ NU BASEMENT 1 0 EO `n/ ED / En 9 10 / En 9 14) ED / ED 0 0'-0"AFF@ - ILI BASEMENT 2 POTTER ROEMER MODEL # 5855 POST INDICATOR HtU HIL) 4 M cri 1-6 4. (0-5.5) RED 4" MUELLER P2360-6 GATE VALVE 2 1/2" FIRE HOSE VALVE W/ CAP AND CHAIN POTTER ROEMER # 4065 0 . 2 1/2" FIRE HOSE VALVE W/ CAP AND CHAIN POTTER ROEMER # 4065 ul co I 2 1/2" FIRE HOSE VALVE W/ CAP AND CHAIN POTTER ROEMER # 4065 i 4 e Op��,P .�Oo� O5�'G'�Pv <O I.I 2 1/2" FIRE HOSE VALVE W/ CAP AND CHAIN POTTER ROEMER # 4065 �s- er 4" STANDP PE SEE SH- 3 OF FOR PIPE RO NG (1-1) III N \ 00 jca N've<QQ�� 2-0 2 1/2" FIRE HOSE VALVE W/ CAP AND CHAIN POTTER ROEMER # 4065 HANGER LEGEND m 1 ' 5" 6" 5" / / / i 1 (6" SUPPLY PIPING) 8'-6" OFOW TO Q 6" SYSTEM RISERS 9'-1" OFOW TO CE 21/2" DRAIN PIPING STAIR #1 SECTION 'B' (FACING NORTH) 0 2 4 SCALE 1/2"=1'-0" SPRINKLER LEGEND T2 2.5" EXPRESS DRAIN 6X4"RC N STAIR #1 FLOOR 3 (19 0 4 8 SCALE 1/4"=1'-0" 2" B/L 2.5" EXPRESS DRAIN N STAIR #1 FLOOR 1-2 (ID 0 4 8 SCALE 1/4"= 1' 0' ABBREVIATIONS SYM MANUFACTURER TYPE MODEL HEAD FINISH ESCUTCHEON FINISH ORIFICE SIZE THREAD SIZE TEMP. RATING QUANTITY AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO SYMBOL LEGEND 2.5" EXPRESS DRAIN STAIR #1 BASEMENT 1 0 4 8 SCALE 1/4"= 1' 0 N 2.5" EXPRESS DRAIN STAN RISER FEED STAIR #1 BASEMENT 2 0 4 8 SCALE 1/4' =11-0' - QUALITY CONTROL BY: DATE: REVISIONS STAIR #2 FLOOR 3 0 4 8 SCALE 1/4"=1'-0" / 4" STANDPII HOSE VALV i 0 Q 2-9" C� 5'-4" STANDPIPE It:29 STAIR #2 FLOOR 1-2 0 4 8 SCALE 1/4"=1'-0" / / / / / / / / 4' STANDPII HOSE VALV n- Com• z co 2'-9" E W/ FI E TYPICAL 5'-4" STAIR #2 BASEMENT 1-2 0 4 8 SCALE 1/4"=V-0" POTTER ROEMER MODEL # 5876 TWO-WAY OUTLET WITH (2) #4085 FIRE HOSE VALVES ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE BOD CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING APPROVED FOR FABRICATION AREA BY DATE BY 11/30/01 BC REASON FOR REVISION REVISIONS PER CITY OF TUKWILA: ADD STANDPIPE IN EACH STAIRWELL. DATE POTTER ROEMER MODEL # 5855 POST INDICATOR LT GRN 4" MUELLER P2360-6 GATE VALVE 0 114 6- 1 LT GRN 11 LT GRN STAIR #2 SECTION 'D' (FACING SOUTH) 0 2 4 SCALE 1/2"=1'-0" CONTRACT WITH CONSTRUCTION ASSOCIATES P.O. BOX 975 LYNNWOOD, WA. 98046-0975 PROJECT MANAGER : MARK GARRIBO PHONE : (425) 774-3821 FAX : (425) 774-9065 SUPERINTENDENT: PHONE: FAX : LT GRN I 61OU0: De, e` - En/ o) v ED / / ED / in 10/ ED/ in 9 ED CV er rn LT GRN co N LT GRN LT GRN er rO c er 0 • LT GRN LT GRN er 2 1/2" FIRE HOSE VALVE W/ CAP AND CHAIN POTTER ROEMER # 4065 2 1/2" FIRE HOSE VALVE W/ CAP AND CHAIN POTTER ROEMER # 4065 • 1, LT GRN 7: ) 1252. 0 LT GRN LT GRN 4" SN TO STANDPIPE TIE-IN SEE PIPING ON SHT 3 OF 9 LT GRN 2 1/2" FIRE HOSE VALVE W/ CAP AND CHAIN POTTER ROEMER # 4065 STAIR #2 SECTION 'C' (FACING NORTH) 0 2 4 SCALE 1/2"= V-0" f1 50% REDUCED !CAUTION! CERTIFICATE OF COMPETANCY STAMP KEY PLAN SMITH FIRE SYSTEMS, INC. 1106 54th AVE EAST TACOMA, WA 98424 CONTR. REG. NO. SMITHFS1360T Bus: ( 253) 926 -1880 FAX: ( 253) 926 - 2350 SOUTHCENTER STORAGE 5950 SOUTHCENTER BLVD. TUKWILA, WASHINGTON DESIGNER DATE SHEET JOB NO. B. COLLINS 11/30/01 9 OF • T2-229 1 15'-4 Js — 4,. 15'— SAND TRAP SEE CIVIL DWGS. _1 .s i r,-+ —1V Cn SAND TRAP SEE DWGS. QW WEATHERPROOF H/S, 110C H/S, 75C © MANUAL PULL STATION O SMOKE DET. ADDRESSABLE FACP W/DIALER FACP EXPDR ANN FIRE EXPANDER PANEL FIRE ALARM ANNUNCIATOR INITIATING CIRCUIT, 16 GA., 2 COND. FIREWIRE - - SIGNAL CIRCUIT, 14 GA., 2 C❑ND, FIREWIRE Wv'V V END OF LINE DEVICE, INDICATING CIRCUIT, FIDE ALA2 v RISE2 DIAG2A v SIGNALLING (INDICATING) CIRCUITS INITIATING CIRCUITS TYPICAL DQ = DUCT DETECTOR HVAC - DUCT DETECTI❑N CIRUIT IC7 TYPICAL TYPICAL TYPICAL SC6 ELEVATOR SHUT DOWN =WATER FLOW DETECTOR WATERFL❑W CIRUIT I06 H/S FLOOR F3 SC5 (TYP OF 12) (TYP OF 10) H/S (TYP, OF 2) (TYP, OF 1) IC5 (TYP. OF 2) (TYP. OF 1) FLOOR F2 SC4 UP STAIR (TYP OF 11-1W.P,) (TYP, OF 2) (TYP, OF 1) H/S FLOOR F1 SC3 ANNUN- CIATOR (TYP OF 9) (TYP, OF 5) (TYP, OF 1) C) H/S FLOOR B1 SC2 FILE: 1412 1.1 L/, • ASVNT, 2 FL -OR fLA\ 1/8' = FLOOR B2 SIGNAL CIRCUIT 1 H/S (TYP, OF 2) (TYP, OF INITIAT R1 RISER RATED FIRE QTY, (6) SC=SIGNAL CIRCUITS 14GA„ 2 COND., FIRE WIRE, IN CONDUIT 8 ' & BELOW, QTY, (7) IC=INITIATING CIRCUTIS 16GA., 2 COND., FIRE WIRE, IN CONDUIT 8' & BELOW, QTY, (1) R1=RISER RATED FIRE WIRE, t SO I04 I03 IO2 =PIV VALVE TUKWILA FIRE DEP, Please call: 575,44 and give this job No. and exact address for down or restoration a RTMEN( 7 shut., aprovai, JOB NUMBER AT1412 SCALE 1/8"=V ' DATE 3-14-02 DRAWN BY RAN CHECKED BY \M M ) (REV ISIONS AS -BUILT �--1 V , .---- „ . 1) _. ACCEPTED G CIR T 1 Without Comments As Noted In Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize viola tions of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings a ter iidate will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by STAIR Date: j' / y ©2_ By: v UP ASVNT, 2 FL -OR fLA\ 1/8' = FLOOR B2 SIGNAL CIRCUIT 1 H/S (TYP, OF 2) (TYP, OF INITIAT R1 RISER RATED FIRE QTY, (6) SC=SIGNAL CIRCUITS 14GA„ 2 COND., FIRE WIRE, IN CONDUIT 8 ' & BELOW, QTY, (7) IC=INITIATING CIRCUTIS 16GA., 2 COND., FIRE WIRE, IN CONDUIT 8' & BELOW, QTY, (1) R1=RISER RATED FIRE WIRE, t SO I04 I03 IO2 =PIV VALVE TUKWILA FIRE DEP, Please call: 575,44 and give this job No. and exact address for down or restoration a RTMEN( 7 shut., aprovai, JOB NUMBER AT1412 SCALE 1/8"=V ' DATE 3-14-02 DRAWN BY RAN CHECKED BY \M M ) (REV ISIONS AS -BUILT �--1 V , .---- „ . 1) _. ACCEPTED G CIR T 1 Without Comments As Noted In Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize viola tions of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings a ter iidate will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: j' / y ©2_ By: v Sf E r Ai- „if l2r=7' 3 3 12)-41cE)) F I L MAR- 8 2002 4i X23 U U 0 CN n n FILE: 1412 1.2 3ASEVE\ 1/8'=1' T 1 FL o� PLA\ u A ❑W WEATHERPROOF H/S, 110C H/S, 75C © MANUAL PULL STATION O SMOKE DET. ADDRESSABLE FACP W/DIALER FIRE EXPANDER PANEL FACP EXPDR ANN FIRE ALARM ANNUNCIATOR INITIATING CIRCUIT, 16 GA., 2 COND. FIREWIRE - SIGNAL CIRCUIT, 14 GA., 2 COND, FIREWIRE VVV VV END OF LINE DEVICE, INDICATING CIRCUIT, FIDE ALAR v RISER IAG2A v SIGNALLING (INDICATING) CIRCUITS FLOOR F3 FLOOR F2 FLOOR F1 FLOOR B1 INITIATING CIRCUITS TYPICAL O = DUCT DETECTOR HVAC - DUCT DETECTI❑N CIRUIT IC7 TYPICAL TYPICAL TYPICAL =WATER FLOW =OSY =PIV DETECTOR OSY VALVE PIV VALVE SC6 ELEVATOR SHUT DOWN H/S WATERFL❑W CIRUIT E IC6 SC5 (TYP OF 12) (TYP OF 10) H/S (TYP, OF 2) (TYP, OF 1) IC5 (TYP, OF 2) (TYP, OF 1) E SC4 (TYP OF 11-1 W,P,) H/S (TYP, OF 2) (TYP, OF 1) IC4 SC3 ANNUN- CIATOR (TYP OF 9) H/S FACP 5820XL W. EXTENDER 5495 (TYP, OF 5) (TYP, OF 1) IC3 SC2 FLOOR B2 SIGNAL CIRCUIT 1 (TYP OF 10) H/S (TYP, OF 2) (TYP. OF 1) E IC2 INITIATING CIRCUIT 1 R1 RISER RATED FIRE WIRE QTY, (6) SC=SIGNAL CIRCUITS 14GA., 2 COND., FIRE WIRE, IN CONDUIT 8 ' & BELOW. QTY, (7) IC=INITIATING CIRCUTIS 16GA., 2 COND., FIRE WIRE, IN CONDUIT 8' & BELOW, QTY. (1) R1=RISER RATED FIRE WIRE, /JOB NUMBER AT1412_1.2 SCALE 1/8"=1' DATE 3-14-02 DRAWN BY RAN CHECKED BY Q./1M J /REVISIONS AS -BUILT ry L_ L (REFERENCE SHEET 1 .2 )-; ____ 150- -C 0" T MIIIIIIIT 41'-7" 108'-5" 15'-2" 1 23'-4" 15'-4" 5'-4" 12'-0" 12'-0" 5'-4" 15'-4" 23'-4" 5'-4" 9'-10" 1 a'-10" 2'-10" 111,1.1 IN 0 . 016 Aribillthos...... o i 0 I` -,,_,_, 0 (IN) no 'Th 0 7 ftlillimillihi r. I I 1 �� 0 1` in &SIM I I kl- W _wi.p.i....... I o . a .1/4 ... .... .... 7111..... ......477......w. a ..... ,, irk lirt �.i ® f -T4----_. 'll ,.._0 --......._ 0 Jr 00 o 00 o rI CO 1 I ``-. ,�`,, 00 00 __.� GG rn _ G _ '� �, fir` ---%c) _.tea �__ me _�_ _ ... ��;�� �_ 00 O O O CO II ii �` Iri IW i ©i 0 q ALLWA Ai ■. 00 0 Go Q 1 I 1 W �v 00 4 Wit 41 MONS winummenk oritiamir EDGE OF'. SLAB 00 J J 1- iI(:: 1j i i = .- ;• 1j ' O in1 It 1 II N cv Es SMIMM1111. DASHED LlNE'. USE 3-5/8" MTL. STUDS AT THIS Q D MIMI I INDICATE FAC SIDE OF STA R IN LIEU OF 6" ON 0 - �� •F FINISH BASEMENT 0 E AND BASEMENT 0 M wpm AS TWO LEVELS - IF REQUIRED TO Op J t� 0 i� =Mti„ ACHIEVE 4'- ” CLEAR HALLWAY. i.� 11 ► ► WOW .x Er 1CLR - Z. 0 I � �-1SOgoR��N Lo Z OIL o o UP . 1r�IN. PROVIDE 1 o A L WAY Y " 3" 4- RISEP, EMERGENCY Q -4 _I ;r, EGRESS N ELEVATOR LIGHTING CAB � 0 �+ o 1 N I ���wtIwf 1111.••••• -� •'� O I Al,_ L- ► FACP 1 �`'- 'La) _7..,...v --- i ---- `� J C XP)JR TLT. ��''- OFF CE �_ '�<,.r,' 1 ...�t,1,:r�>,: ;'s, „� = �:. ; it Q Ai Ti •t' ;'`sib#..;K, .::s YNKL•• `4� ` _ - '23 " ie `' 1 ' ���-- 6• SIG , AL CIRCUITS / ' - co,I ®i 00 ''',- 1111 1 I lr]1 rn J '' m �0 s,. -.5" Sq 'ES-, ,_ , nir- MMIMMINICINMEMIIIIII NM 3'-4 CO ANN �, -`- ---, 15'- 2" ; 3 \ 4 S/T� C Wq ‘ SLA: • ,r- 9,, �4 3 4" 7s'\ 134/1NLk SE �� \� 6.. *****, ^`` 2 � i - ` -- POWER FROM FAC' ; -/ �' 1/' o ---1 X1/2.. g04� v NG. LOBBY LOADING �� m 00 o m • o . lift 1 ' �44 s 13•`9„ (9) gROS o Ty CO • P TRDReD rT�INqL. ALN / ',,, e, o o13) Nc• , • ,... ' q L �i-, ..• 0 0 /I .----,-___ -.... . ......7........... 43, 2,. 12',0 0 0 o N q0 — l Sed ` G 11',3 — _ co GG O a I�' P ` 11111a:i1_ 0TA 111111111 illiIllIlIllIllNiihmhh._ R �• 0�.mini II - cri (EXIT 1■■■��■■■ '' _ I iistr` v. ► 13'-1" 8” 10 r: i jt SLAB OPNG. �, 130'-0" �4" 3'-4-1/4" 20'-0" 150'-0" 2' 0„ FILE: 1412 1.2 3ASEVE\ 1/8'=1' T 1 FL o� PLA\ u A ❑W WEATHERPROOF H/S, 110C H/S, 75C © MANUAL PULL STATION O SMOKE DET. ADDRESSABLE FACP W/DIALER FIRE EXPANDER PANEL FACP EXPDR ANN FIRE ALARM ANNUNCIATOR INITIATING CIRCUIT, 16 GA., 2 COND. FIREWIRE - SIGNAL CIRCUIT, 14 GA., 2 COND, FIREWIRE VVV VV END OF LINE DEVICE, INDICATING CIRCUIT, FIDE ALAR v RISER IAG2A v SIGNALLING (INDICATING) CIRCUITS FLOOR F3 FLOOR F2 FLOOR F1 FLOOR B1 INITIATING CIRCUITS TYPICAL O = DUCT DETECTOR HVAC - DUCT DETECTI❑N CIRUIT IC7 TYPICAL TYPICAL TYPICAL =WATER FLOW =OSY =PIV DETECTOR OSY VALVE PIV VALVE SC6 ELEVATOR SHUT DOWN H/S WATERFL❑W CIRUIT E IC6 SC5 (TYP OF 12) (TYP OF 10) H/S (TYP, OF 2) (TYP, OF 1) IC5 (TYP, OF 2) (TYP, OF 1) E SC4 (TYP OF 11-1 W,P,) H/S (TYP, OF 2) (TYP, OF 1) IC4 SC3 ANNUN- CIATOR (TYP OF 9) H/S FACP 5820XL W. EXTENDER 5495 (TYP, OF 5) (TYP, OF 1) IC3 SC2 FLOOR B2 SIGNAL CIRCUIT 1 (TYP OF 10) H/S (TYP, OF 2) (TYP. OF 1) E IC2 INITIATING CIRCUIT 1 R1 RISER RATED FIRE WIRE QTY, (6) SC=SIGNAL CIRCUITS 14GA., 2 COND., FIRE WIRE, IN CONDUIT 8 ' & BELOW. QTY, (7) IC=INITIATING CIRCUTIS 16GA., 2 COND., FIRE WIRE, IN CONDUIT 8' & BELOW, QTY. (1) R1=RISER RATED FIRE WIRE, /JOB NUMBER AT1412_1.2 SCALE 1/8"=1' DATE 3-14-02 DRAWN BY RAN CHECKED BY Q./1M J /REVISIONS AS -BUILT ry L_ L (REFERENCE SHEET 1 .2 PTD. MTL. PARAPET EDGE OF SLAB 12'-10" FIST PL_ PLA 1/B'=1' i "1 WEATHERPROOF H/S, 110C H/S, 75C E MANUAL PULL STATION 0 SMOKE DET, ADDRESSABLE FACP W/DIALER FIRE EXPANDER PANEL FACP EXPDR ANN FIRE ALARM ANNUNCIAT❑R INITIATING CIRCUIT, 16 GA., 2 COND. FIREWIRE - SIGNAL CIRCUIT, 14 GA., 2 C❑ND, FIREWIRE V✓ VW END OF LINE DEVICE, INDICATING CIRCUIT, FI2E ALAS v RISER DIAGRA V SIGNALLING (INDICATING) CIRCUITS FLOOR F3 FLOOR F2 FLOOR F1 FLOOR B1 INITIATING CIRCUITS TYPICAL DO = DUCT DETECTOR HVAC - DUCT DETECTION CIRUIT IC7 TYPICAL TYPICAL TYPICAL =WATER FLOW DETECTOR =❑SY =PIV VALVE PIV VALVE SC6 ELEVATOR SHUT DOWN H/S WATERFL❑W CIRUIT E IC6 SC5 (TYP OF 12) (TYP OF 10) H/S (TYP, OF 2) (TYP. OF 1) IC5 (TYP. OF 2) (TYP. OF 1) SC4 (TYP DF 11-1 W.P.) H/S (TYP, OF 2) <TYP. OF 1) IC4 SC3 ANNUN- CIATOR (TYP OF 9) H/S FACP 5820XL W. EXTENDER 5495 (TYP. OF 5) (TYP. OF 1) IC3 SC2 FLOOR B2 SIGNAL CIRCUIT 1 (TYP OF 10) H/S IC2 (TYP. OF 2) (TYP. OF 1) 0 INITIATING CIRCUIT 1 R1 RISER RATED FIRE WIRE QTY. (6) SC=SIGNAL CIRCUITS 14GA„ 2 COND., FIRE WIRE, IN CONDUIT 8 ' & BELOW. QTY, (7) IC=INITIATING CIRCUTIS 16GA., 2 COND., FIRE WIRE, IN CONDUIT 8' & BELOW. QTY. (1) R1=RISER RATED FIRE WIRE. (JOB NUMBER AT1412 SCALE 1 /8"=1' DATE 3-14-02 DRAWN BY RAN CHECKED BY �M M 1 REVISIONS CAS -BUILT I- V (206)762-4117 oo O o rn SEATTLE, WA U 0 (f) L_ U /REFERENCE SHEET FILE: 1412_ 1.3 1.3 0o ao 00 00 PTD. MTL. PARAPET EDGE OF SLAB 12'-10" FIST PL_ PLA 1/B'=1' i "1 WEATHERPROOF H/S, 110C H/S, 75C E MANUAL PULL STATION 0 SMOKE DET, ADDRESSABLE FACP W/DIALER FIRE EXPANDER PANEL FACP EXPDR ANN FIRE ALARM ANNUNCIAT❑R INITIATING CIRCUIT, 16 GA., 2 COND. FIREWIRE - SIGNAL CIRCUIT, 14 GA., 2 C❑ND, FIREWIRE V✓ VW END OF LINE DEVICE, INDICATING CIRCUIT, FI2E ALAS v RISER DIAGRA V SIGNALLING (INDICATING) CIRCUITS FLOOR F3 FLOOR F2 FLOOR F1 FLOOR B1 INITIATING CIRCUITS TYPICAL DO = DUCT DETECTOR HVAC - DUCT DETECTION CIRUIT IC7 TYPICAL TYPICAL TYPICAL =WATER FLOW DETECTOR =❑SY =PIV VALVE PIV VALVE SC6 ELEVATOR SHUT DOWN H/S WATERFL❑W CIRUIT E IC6 SC5 (TYP OF 12) (TYP OF 10) H/S (TYP, OF 2) (TYP. OF 1) IC5 (TYP. OF 2) (TYP. OF 1) SC4 (TYP DF 11-1 W.P.) H/S (TYP, OF 2) <TYP. OF 1) IC4 SC3 ANNUN- CIATOR (TYP OF 9) H/S FACP 5820XL W. EXTENDER 5495 (TYP. OF 5) (TYP. OF 1) IC3 SC2 FLOOR B2 SIGNAL CIRCUIT 1 (TYP OF 10) H/S IC2 (TYP. OF 2) (TYP. OF 1) 0 INITIATING CIRCUIT 1 R1 RISER RATED FIRE WIRE QTY. (6) SC=SIGNAL CIRCUITS 14GA„ 2 COND., FIRE WIRE, IN CONDUIT 8 ' & BELOW. QTY, (7) IC=INITIATING CIRCUTIS 16GA., 2 COND., FIRE WIRE, IN CONDUIT 8' & BELOW. QTY. (1) R1=RISER RATED FIRE WIRE. (JOB NUMBER AT1412 SCALE 1 /8"=1' DATE 3-14-02 DRAWN BY RAN CHECKED BY �M M 1 REVISIONS CAS -BUILT I- V (206)762-4117 oo O o rn SEATTLE, WA U 0 (f) L_ U /REFERENCE SHEET FILE: 1412_ 1.3 1.3 CAD CA CAn SEC -\D FL LA\ 1/8'=1' O J QW WEATHERPROOF H/S, 110C H/S, 75C E MANUAL PULL STATION CS) SMOKE EET, ADDRESSABLE FACP W/DIALER FIRE EXPANDER PANEL FACP EXPDR ANN FIRE ALARM ANNUNCIATOR INITIATING CIRCUIT, 16 GA., 2 COND. FIREWIRE - SIGNAL CIRCUIT, 14 GA,, 2 COND. FIREWIRE Wv\'VV END OF LINE DEVICE, INDICATING CIRCUIT, FIDE ALARv RISER IAGRA v SIGNALLING (INDICATING) CIRCUITS FLOOR F3 FLOOR F2 FLOOR F1 FLOOR Bi INITIATING CIRCUITS TYPICAL D0 = DUCT DETECTOR HVAC - DUCT DETECTION CIRUIT I07 TYPICAL TYPICAL TYPICAL A=WATER FLOW WFD DETECTOR =❑SY VALVE SC6 ELEVATOR SHUT DOWN H/S WATERFLOW CIRUIT I06 SC5 (TYP OF 12) (TYP OF 10) H/S (TYP. OF 2) (TYP. OF 1) I05 (TYP. OF 2) (TYP, OF 1) SC4 (TYP OF 11-1 WP.) H/S (TYP, OF 2) (TYP, OF 1) IC4 SC3 ANNUN- CIATOR (TYP OF 9) H/S FACP 5820XL W, EXTENDER 5495 (TYP, OF 5) (TYP, OF 1) P I03 SC2 FLOOR B2 SIGNAL CIRCUIT 1 (TYP OF 10) H/S (TYP, OF 2) GYP. OF 1) a o IO2 INITIATING CIRCUIT 1 R1 RISER RATED FIRE WIRE QTY, (6) SC=SIGNAL CIRCUITS 14GA,, 2 COND,, FIRE WIRE, IN CONDUIT 8 ' & BELOW. QTY, (7) IC=INITIATING CIRCUTIS 16GA,, 2 COND., FIRE WIRE, IN CONDUIT 8' & BELOW, QTY. (1) R1=RISER RATED FIRE WIRE. =PIV VALVE FILE: 1412_1 .4 JOB NUMBER AT1412 SCALE 1 /8"=1' DATE 3-14-02 DRAWN BY RAN CHECKED BY QM M REVISI❑NS AS -BUILT r t0 0 r � V J C >> 7 h I v) rn < V J 3 w U ( ) F --d V U U /REFERENCE SHEET 1.L 150-0" 41'-7" 108'-5" 9'-10" 5'-4" 19'-8" 5'-4" 19'-8" 5'-4" 9'-10" 9'-10" 5'-4" 19'-8" 5'-4" 19'-8" 5'-4" 9'-10" DO 11 11 It 11 0 it—.1111.- 11 ifiraift 1 0 I 00 1 F IIx DO (0_9 00 0 1 pp 11 00 q \ `� �` 11 00 are 0 ilk& co ft 11 �"0,81 ++ + o . 1+ ®IIID 00 O 11 tl •I 00 . o +1 DD DD DD ++ 11 1f O W00 -L-- --I- o 00 -c r ALLWA F/Et = 00 1 00 Q _ 00 OD t 1 a — 11 00 11 O DD 1 O 00 00 J 1® _ l - 0Q 00 00 DO 0 CO �o J I i • W DD = Q 10 00 G0 -J 0 LL, Q — 0l -/ 1 CO +1 00 ++ 00 I) 00 00 -7..1I� 00 o 00 0 UP STAIR DN www 00 �� 0 .-- ›-GD Q 1 1 y- i<00 t ' in W N 00000 FA RISER o - -01 a,. 00 ``0 ©` V O Q ® - "'v 0 00 pro, I i f� o, ....a, ,... „�` ` �� v ��Alik- llb. �.. e `00 - . �: 411111..._00 . %"Rwilmil....._ o .♦ 7'-4" 7'-10" 00 �n o >44Pit r -111111F , ((21)) .. .. zo rap L...15' 0 - '„ OpN0 � 11 CO r E OF SLAB 15-6" 0 ---_,,,..._ 00 h 00 4,./' 4 OpNc. 00 00 • -- ------ o 00 ; HMI 5' 8" �� 0IIIIIII m 00 ts,' ii- 1111111 o A 4" ---111-11-PW/ 0000 iindi 74. 5',7j., E OF SLAB l 00 40 --ED 49'-6" 40'-8" 39'-10' '`-- 2'-10" 130'-0" 3'-7" 20'-0" �_ 150'-0" SEC -\D FL LA\ 1/8'=1' O J QW WEATHERPROOF H/S, 110C H/S, 75C E MANUAL PULL STATION CS) SMOKE EET, ADDRESSABLE FACP W/DIALER FIRE EXPANDER PANEL FACP EXPDR ANN FIRE ALARM ANNUNCIATOR INITIATING CIRCUIT, 16 GA., 2 COND. FIREWIRE - SIGNAL CIRCUIT, 14 GA,, 2 COND. FIREWIRE Wv\'VV END OF LINE DEVICE, INDICATING CIRCUIT, FIDE ALARv RISER IAGRA v SIGNALLING (INDICATING) CIRCUITS FLOOR F3 FLOOR F2 FLOOR F1 FLOOR Bi INITIATING CIRCUITS TYPICAL D0 = DUCT DETECTOR HVAC - DUCT DETECTION CIRUIT I07 TYPICAL TYPICAL TYPICAL A=WATER FLOW WFD DETECTOR =❑SY VALVE SC6 ELEVATOR SHUT DOWN H/S WATERFLOW CIRUIT I06 SC5 (TYP OF 12) (TYP OF 10) H/S (TYP. OF 2) (TYP. OF 1) I05 (TYP. OF 2) (TYP, OF 1) SC4 (TYP OF 11-1 WP.) H/S (TYP, OF 2) (TYP, OF 1) IC4 SC3 ANNUN- CIATOR (TYP OF 9) H/S FACP 5820XL W, EXTENDER 5495 (TYP, OF 5) (TYP, OF 1) P I03 SC2 FLOOR B2 SIGNAL CIRCUIT 1 (TYP OF 10) H/S (TYP, OF 2) GYP. OF 1) a o IO2 INITIATING CIRCUIT 1 R1 RISER RATED FIRE WIRE QTY, (6) SC=SIGNAL CIRCUITS 14GA,, 2 COND,, FIRE WIRE, IN CONDUIT 8 ' & BELOW. QTY, (7) IC=INITIATING CIRCUTIS 16GA,, 2 COND., FIRE WIRE, IN CONDUIT 8' & BELOW, QTY. (1) R1=RISER RATED FIRE WIRE. =PIV VALVE FILE: 1412_1 .4 JOB NUMBER AT1412 SCALE 1 /8"=1' DATE 3-14-02 DRAWN BY RAN CHECKED BY QM M REVISI❑NS AS -BUILT r t0 0 r � V J C >> 7 h I v) rn < V J 3 w U ( ) F --d V U U /REFERENCE SHEET 1.L 00 00 00 00 00 CO 00 00 FILE: 1412_ 1.5 THIR7 FLIIR PLA 1/81=1' W WEATHERPROOF H/S, 110C Li H/S, 75C ® MANUAL PULL STATI❑N SMOKE DET, ADDRESSABLE FACP W/DIALER FIRE EXPANDER PANEL FACP EXPDR ANN FIRE ALARM ANNUNCIAT❑R INITIATING CIRCUIT, 16 GA., 2 COND. FIREWIRE - - SIGNAL CIRCUIT, 14 GA,, 2 C❑ND, FIREWIRE VvVV1/V END OF LINE DEVICE, INDICATING CIRCUIT, FI REI ALAS v IAGRA v SIGNALLING (INDICATING) CIRCUITS FLOOR F3 FLOOR F2 FLOOR F1 FLOOR El INITIATING CIRCUITS TYPICAL DO = DUCT DETECTOR HVAC - DUCT DETECTI❑N CIRUIT IC7 TYPICAL TYPICAL TYPICAL A=WATER FLOW ❑SY =PIV WFD DETECTOR /❑SY\ VALVE PIV VALVE SC6 ELEVATOR SHUT DOWN H/S WATERFL❑W CIRUIT IC6 SC5 (TYP OF 12) (TYP OF 10) H/S (TYP, OF 2) (TYP, OF 1) IC5 (TYP, OF 2) CTYP, OF 1) SC4 CTYP OF 11-1 W,P,) H/S (TYP, OF 2) CTYP, OF 1) IC4 SC3 ANNUN- CIATOR CTYP OF 9) H/S SC2 FLOOR B2 SIGNAL CIRCUIT 1 (TYP OF 10) H/S IC3 FACP 5820XL W, EXTENDER 5495 (TYP, OF 5) (TYP, OF 1) (TYP, OF 2) (TYP, OF 1) © 0 IC2 INITIATING CIRCUIT 1 R1 RISER RATED FIRE WIRE QTY. (6) SC=SIGNAL CIRCUITS 14GA„ 2 COND., FIRE WIRE, IN CONDUIT 8 ' & BELOW, QTY. (7) IC=INITIATING CIRCUTIS 16GA„ 2 COND., FIRE WIRE, IN CONDUIT 8' & BELOW, QTY. (1) R1=RISER RATED FIRE WIRE. JJ0B NUMBER AT1412 SCALE 1/8"=V DATE 3-14-02 DRAWN BY RAN CHECKED BY QM M (-REVISIONS AS -BUILT 1-- V U 0 (ID U � L_ U U U Q j) U O (f) o_ %REFERENCE SHEET 1 .5 J � J SCOPE: • INSTALLATION OF AN AES RADIO COMMUNICATOR TO REPLACE EXISTING PHONE LINES • ADDING MANUAL PULL STATION NEXT TO EXISTING SK-5820XL FACP Q FRE CONTROL ROOM LOCATED AT SOUTH WEST CORNER OF BUILDING DO NOT PENETRATI: THE BOTTOM OF FALP. DUSTING SLC CONT. Area Zone Des oripTian • 1 B1 VALVE TAMPERS 2 B2 VALVE TAMPERS 3 LOBBY SMOKE DETECTORS 3-82 • 4 B2 WEST STAR PULL STATION • 5 YARD PN • 6 NORTH OS&Y IN PIT • 7 SOUTH OS&Y IN PIT • 8 82 LOBBY SMOKE 9 ELEVATOR TAMPER • 10 ELEVATOR ROOM SMOKE • 12 EAST STAR PULL 82 • 20 GROUND FLOOR SWF • 21 MAN FLOOR VALVE TAMPER • 22 WEST STAR PULL STATION 23 ELECTRICAL ROOM SMOKE DET • 24 OFFICE PULL STATION * 25 LOBBY PULL STATION 26 81 LOBBY SMOKE • 27 MAN FLR EAST PULL STATION • 28 MAN FIR EAST STAIR PULL 29 OFFICE SMOKE DET • 31 1ST FLOOR VALVE TAMPERS • 32 1ST FLOOR WATERFLOW • 33 1ST FLOOR WEST STAR PULL 34 1ST FLOOR LOBBY SMOKE 35 1ST FLOOR EAST STAIR PULL 41 2ND FLOOR VALVE TAMPERS 42 2ND FLOOR SWF • 43 2ND FLOOR WEST STAR PULL • 44 2ND FLOOR LOBBY SMOKE • 45 2ND FLOOR EAST STAR PULL • 51 3RD FLOOR VALVE TAMPERS • 52 3RD FLOOR SWF * 53 3RD FLOOR WEST STAIR PULL 54 3RD FLOOR LOBBY SMOKE • 55 3RD FLOOR EAST STAIR PULL 1 1 NAC 11 1 2 NAC 1 3 NACf 1 4 NAC I4 1 5 NAC f5 1 6 NAC f6 1 7 ELEVATOR RELAY 1 1 8 ELEVATOR RELAY 2 34 1 LEVEL 2 NAC 1 34 2 LEVEL 1 NAC 2 34 3 1ST FLOOR NAC 3 34 4 2ND FLOOR NAC 4 34 5 SWF BELL NAC 5 34 6 POWER SUPPLY TRIGGER NAC 6 34 7 PRIMARY ELEVATOR RECALL BY-PASS 34 8 ALTERNATE ELEVATOR RECALL BY-PASS FIRE ALARM SYMBOL LEGEND �,� n,M� ., M• ff �R a R� �« SYMBOL DESCRIPTION MOUNTING IFACPI FIRE ALARM CONTROL PANEL WALL -TOP 0 66' Efl FIRE ALARM POWER SUPPLY FIELD VERIFY IFSAI ORE SYSTEM ANNUNCIATOR WALL -TOP 0 66' MCI FIRE/SMOKE DAMPER BY OTHERS 0 SMOKE DETECTOR CEIUNG *— DUCT SMOKE DETECTOR 8Y OTHERS 01 HEAT DETECTOR CEILING © ADDRESSABLE CONTROL MODULE FIELD VERIFY © ADDRESSABLE MONITOR MODULE FIELD VERIFY © MANUAL PULL STATION WALL 0 48' ® CONTROL RELAY (MULTI -VOLTAGE) FELD VERIFY ADDRESSABLE RELAY MODULE FIELD VERIFY MAGNETIC DOOR HOLDER FELD VERIFY WATER FLOW SWITCH BY OTHERS I] VALVE SUPERVISORY SWITCH BY OTHERS R BELL BY OTHERS 0 CEIUNG MOUNT STROBE FIELD VERIFY 0 CEIUNG MOUNT HORN / STROBE FIELD VERIFY 0 CEIUNG MOUNT SPEAKER / STROBE FIELD VERIFY ) CBUNG MOUNT SPEAKER FIELD VERIFY HORN WALL 0 10'-0 HORN / STROBE WALL 80'-96' DQ SPEAKER / STROBE WALL 80'-96' ID< SPEA<ER WALL 0 90' STROBE WALL 80'-96' ABBREVIATION DESCRIPTION urWGw) 75rLi-` E 0001190 G WITH GUARD P PENDENT MOUNT 0 ,-DencE ADDRESS-, Q L10001(OR D01 DEE19 LRRa� (o « u - iEs oL�Ecra+ NODULE 9) R RESIDENTIAL (110V) S SOUNDER BASE WP WEATHER PROOF EOL END OF UNE RESISTOR EOLR END OF UNE RELAY 1- 16 2 TWP MRE TM 'Mara cauxr WRRE SIZE AWG AMERICAN WIRE GAUGE TWP TWISTED PAR TWSP TWISTED SHIELDED PAR FPLP FIRE POWER UNITED PLENUM FPLR FIRE POWER UNITED RISER LorpF or'Es umll EY r.w ` REEOEn NAC NOTIFICATION APPLIANCE CIRCUIT SLC SIGNALUNG UNE CIRCUIT PAIL) HAS 2.3 2018 et -ZCZ•�'i 0 0 0 S K Z V d. Z 2 54,1 ce Cn co 3"; C7 QF_ o 0 o cn CQ Q7t1 x - 0. 0 ad d 0 0 ae 0 1'4 TUKWILA SELF STORAGE - AES 5950 SOUTHCENTER BLVD TUKWILA, WA 98188 ZONE LIST, RISER, MAP, LEGEND DRAWN CHECKED DATE 3/28/2018 REYIS0N SCALE NONE FA -1 0 Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformanre 'v i current City standards. Acceptance is subject 4. errors and omissions which do not authorize ,,,orr+ans of adopted standards and oro,nances The Por the adequacy of aesnr r , es+s totalir wdt ' n : oesiper. F,�a;tiQns, ^e1PUo s -evisio,,s tc 't 5 drawings a4e this dace wit, 'a c, rn,- 3cceptance a cl Mil require a resubrmtz, . _v'ser ;'awings fc 5 iasecuent appro.,F+i. Final accepra, ce is svojeet to field test and inspectior uy The Tukwila Fire PPGevention Bureau. Date: — S By: A i T'JKWILA FIRE DEP!' r iea:e c= ►; 2-7-'-•O7 and (,;ivc this --nd exact for s:-ut- ..own ov este 'ion bpproval.