PP - 480 ANDOVER PARK EAST - HEATCON INC. - PERMITS AND PLANS
480 ANDOVER PARK EAST ASSOCIATED PERMITS EL16-0901 14-F-229 D16-0127 16-S-159 16-F-213 16-F-063 D15-0094 16-S-051 15-S-002 14-F-229 16-F-213 4410,144 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 2623049093 Site Address: 480 Andover Park East Suite Number: Floor: 1st Tenant Name: Heatcon Composite Systems New Tenant? XD- Yes ❑ - No Property Owner's Name: CENVEO Mailing Address: 600 Andover Park East Tukwila WA 98188 City State Zip CONTACT PERSON -if there arc questions about the submittal. Name: Jared Brandon Day Telephone: 206-438-3382 Company Name: Cosco Fire Protection Mailing Address: 4308 South 131st Place Tukwila WA 98168 City State Zip E-mail Address: j brandon@coscof ire . com Fax Number: Contractor's City of Tukwila Business License number: BUS - 0995340 Total number of new/relocated devices or sprinkler heads: 356 Valuation of Project (contractor's bid price): $ 13,125.00 Scope of Work (please provide detailed information): To lower and replace existing uprights w/ new uprights on 1x2" nipples w/ 1x" RC from existing branch -lines PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Jared Brandon Plan Permit App.doc Date: 12116/ 14 Day Telephone: 206-438-3382 8/22/14 TFD FP Form 8 Ow% SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 2-4'2-1°4410°11 Site Address: Ac""ve— ' Tenant Name: P ✓N Property Owner's Name: 4Vb A''`i'"''' Mailing Address: 4'15 — I v S1 E Ziv CONTACT PERSON-if''there are questions about the submittal. Name: `� L Company Name: Fi re. er- l -s L . Mailing Address: S2'k Lk5�=- S� t SCE -402. (-LC Suite Number: N/t4- Floor: New Tenant? g- Yes ❑ - No City tt4k7 ewes es State Zip Day Telephone: a53 — 0011 3e-1 o City \ State Zip E-mail Address: 'r ( - 4.0 Fax Number: (Zsi; ) $Z‘, - )033 Contractor's City of Tukwila Business License number: %" S 'CY-144 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 1, i W1 i1- Scope of Work (please provide detailed information): Mee 11 spr--)" IL(c .-{ s PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: / Print Name: NlG7Ti��1 'el -So I L Day Telephone: Plan Permit App.doc Date: 37/11(6 (Z53) 826-OO`jct 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** /r ^ _ -Q_ p King Co. Assessor's Tax No.: Z 6 Z 30 4 — 10/S Site Address: 4.0 ve-r v°�4 Suite Number: AjAk Floor: Tenant Name: /44160 `-` p New Tenant?$- Yes ❑ - No Property Owner's Name: 4q6 4 h r "-I ' i C Mailing Address: TIS &1 ie, STL 21_10 T im City CONTACT PERSON -if there are questions about the submittal. Name: Company Name: Mailing Address: E-mail Address: FIRE SPRINKLERS INC. UvA `1 ls'1 gg State Zip Day Telephone: (253)826-0099 1524 45th St. E. #102 Sumner WA 98390 City Contractor's City of Tukwila Business License number: BUS -0994433 State Zip Fax Number: (253)826-1033 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 14, 1-0. Scope of Work (please provide detailed information): AO 0„6 ..3.J y,� r1/4.4...r 11 owe. t 7' 4. r•¢ioc.-L t,pr-iJ -1 aJ (?i cn-'�'-41^4.1 Guth. 1 1 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE AUTHORIZED AGENT: Signature: Print Name: Plan Permit App.doc Date: S/'"t / Day Telephone: 2S 3 — 8 2C> - 0°31 8/22/14 TFD FP Form 8 4 ittqf CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION Site Address: 480 Andover Park E., TUKWILA, WA Tenant Name:Johnson TI Property Owner's Name:480 Andover Park East, LLC 5N0169 King Co. Assessor's Tax No.:2623049093 Suite Number: Floor: New Tenant? ❑ - Yes ® - No Mailing Address:415 Baker Blvd STE 200 TUKWILA WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: KARA MORROW Day Telephone:(360) 481-4969 Company Name:ALARM CENTER, INC. Mailing Address:PO BOX 3407 E-mail Address:kara@alarmcenterinc.com LACEY WA 98509 City State Zip Fax Number:(360) 438-4244 Contractor's City of Tukwila Business License number: BUS -0992830 Total number of new/relocated devices or sprinkler heads:' 2-' Valuation of Project (contractor's bid price): $13.922.00 Scope of Work (please provide detailed information): INSTALL NEW FIRE ALARM CONTROL UNIT, 1 MAUAL PS, 1 SMOKE, 8 STROBES, 12 HORN STROBES PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: KARA MORROW Plan Permit App.doc Date: 03/10/2016 Day Telephone: (360) 481-4969 8/22/14 TFD FP Form 8 Ott"444 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 480 Andover Park E., TUKWILA, WA King Co. Assessor's Tax No.: 2623049093 Suite Number: Floor: Tenant Name:Johnson TI New Tenant? ❑ - Yes ® - No Property Owner's Name:480 Andover Park East. LLC 5N0169 Mailing Address:415 Baker Blvd STE 200 TUKWILA WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: KARA MORROW Day Telephone: (360) 481-4969 Company Name:ALARM CENTER, INC. Mailing Address:PO BOX 3407 E-mail Address:kara@alarmcenterinc.com LACEY WA 98509 City State Zip Fax Number:(360) 438-4244 Contractor's City of Tukwila Business License number: BUS -0992830 Total number of new/relocated devices or sprinkler heads: 24 Valuation of Project (contractor's bid price): $ 9.289.00 Scope of Work (please provide detailed information): INSTALL NEW FIRE ALARM POWER SUPPLY, 13 STROBES, 110 HORN STROBES PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN WNER AUTHORIZED AGENT: Signatur Print Name: KARA MORROW t2II %Zdk_ Date: Day Telephone: (360) 481-4969 Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 2623049093 Site Address: 480 ANDOVER PARK E., TUKWILA, WA Suite Number: Floor: Tenant Name: SWADDLE DESIGN'S, LLC. Property Owner's Name: SWADDLE DESIGN'S, LLC Mailing Address: 480 ANDOVER PARK E TUKWILAWA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: SCOTT ANDFRSON Day Telephone: (800) 354-1555 Company Name: ALARM CENTER INC. DBA. ACE FIRE & SECURITY/CUSTOM SECURITY Mailing Address: PO BOX 3401 LACEY. WA 98509 City State Zip E-mail Address: SANDERSON@ALARMCENTERINC.COM Fax Number: New Tenant? ❑ - Yes ® - No Valuation of Project (contractor's bid price): $ 795.00 Scope of Work (please provide detailed information): REPLACE EXISTING S.T.U. FIRE ALARM DIALER WITH A.E.S. RADIO COMMUNICATOR. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID BUILDING OWNER OR AUTHORIZED AGENT: JUN cZ ZO'I Signature:TUKWILA FIRE Date: 6 ( // / / y Print Name: SCOTT ANDERSON Day Telephone: (800) 354-1555 12Jr3z Plan Permit App.doc 5/14/10 //r - TFD FP Form 8 7 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Heatcon 480 Andover Park East Permit No.: 16-S-051 Date: March 23, 2016 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) A • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). A. • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. Jr - FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Heatcon 480 Andover Park East Permit No.: Date: Reviewer: 16-S-159 August 9, 2016 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) a ti • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods Tess than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). ▪ 1 • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Heatcon 480 Andover Park East Permit No.: 15-S-002 Date: January 5, 2015 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. ti • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. Inspector: CORRECTION NOTICE/REINSPECTION FEE Permit number: b/IP — 0/ Z TUKWILA FIRE MARSHAL'S OFFICE Office: 206-575-4407 Fax: 206-575-4439 Email: Fire Marshal (a tukwilawa.gov Business Name: /44,"Type of Inspection4H Location Address: Kio 47 Date : to 4: Contact Person :'Th.. Phone Nr1,2_5) 7g'S - 3rA 5 ACTION REQUIRED : C67),1 D -e( D-a‘c74` 74' CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY : l Z 7 / FAILURE TO COMPLY MAY RESULT IN THE ISSUANCE OF A CRI IN CITATION/TICKET. Signature: Biffin 1 ailing Address covibit Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Reins') Fee2.doc Revised 6/17/14 T.F.D. Form F.P. 100 �,,/ 0/ CORRECTION NOTICE/REINSPECTION FEE /YI Inspector: 55 Permit number:bt (rl 2 / TUKWILA FIRE MARSHAL'S OFFICE Office: 206-575-4407 Fax: 206-575-4439 Email: Fire Marshal (a tukwilawa.eov Business Name: C _ j ici Type of Inspectipr l f Locati`��n Address: ` r Date : 7g0// co Con ct ers 0, mvist,4 Phone No. •�' 2g5''.391.6 a5— 3 91Q ACTION REQUIRED : �t�E3 ,1i77,4? fR ces•Jveiri-s14-770.1 cdp.mzor CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY : � 2/14 117 FAILURE TO COMPLY MAY RESULT IN THE ISSUANCE OF A CRIMINAL CITATION/TICKET. Signature: k Billing/Mailing Address : Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Reinsp Fee2.doc Revised 6/17/14 T.F.D. Form F.P. 100 5 -- INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit -ai _Pit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 0371:Texi%...\Type of Inspection: 6t 4H7W67 Address: 4.86Suite #: P Contact Person: a� fif,.04 Special Instructions: Phone No.: eApApproved per applicable codes. Corrections required prior to approval. 7 COMMENTS: eipcss /014 en- Lc c, rfr7AlG, - 6 if- — 5gE-- Cori-g-6uzos%-C krc-rtzE -- Fr /Z Ft ..i 4-L -- Q k_ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 1 Inspector: f AA SIV53 Date: l ( /5 j// 6 Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Ate{ Gtf� Sprinklers: Type of Inspection: `j p Address: Suite #: 7 ee, A -PC— Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. riCorrections required prior to approval. COMMENTS: 56:7,-(1-) C,,d'S 1 00UQ0- t --z_e--P-- -PA'S .R'ru /o cm,.,x,yeeJ 4 l e- r‘P Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ,Cy/S3 Date: /17-sij 6 Hrs.: / . O $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:WaveFfc 1.6n Type Inspecti %% /✓t /WAS- i•i,- Address:.Contact Suite #: eo ,4PE Person: Special Instructions: Phone No.: Approved per applicable codes. nCorrections required prior to approval. COMMENTS: �ic ,61l�-- — /9A5s -DA4f Ddithrs tudta. mil kaid ?Iv l'At /0974e( CO//.ee7C..-1 Neku LSswtOi Needs Shift Inspection: y.ts Hrs.: Sprinklers: Yes Fire Alarm: Hood & Duct: (es Monitor: / ,g.,�s..u. �� n- 6i 23:- Pre -Fire: Permits: YZyYJ( Occupancy Type: inspector:; ,o..5 J Date: ///Z3hG Hrs.: v i / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD - i(Q —(or2 ) Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Type Gam of Inspection: CtZggirc Address: Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 001Z- -i--. Cee.sea el') ASC2,-, 2h - ova-*'- -De) e5 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector`: 1 — /70<-5 Date: loft th 4 Hrs.: 4.O n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 V INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:4717e GO�j Type of Inspection: c� / ` /moi Address:Contact gSpecSuite #: 7g0 /1 -79g - Per on: / Occupancy Type: ial Instructions: Special Phone No.: Approved per applicable codes. COMMENTS: Corrections required prior to approval. 7//t, Assa4 n;:e 64 712? eec-c-77 As -c Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspect ��lZ/� Date: 9 � � � Hrs.. // !ti %ft<,t,,e,. $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: iii Sprinklers: Type of Ins ion: //- Address: Suite #: ygo Aree--- Contact P son: Special Instructions: Occupancy Type: Phone No.: proved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: - 4/14C- .__ Occupancy Type: ?"--s5 .5.-- ' / /k — &S - Al( -,-e -- v-►-_,.- Co -,,t c - 0/4 L Cv t/Q-v- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: J S3 Date: d/j/ /a Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 41/41Cern Type of Inspection: F %\ O,1=tc e, Address:9'o Suite #: ittl-q& Cont ct Person: Pre -Fire: Special Instructions: Phone No.: —Ai s / riApproved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: i Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: —Ai s / /Sr PZer 0 Ge 1171/S 19? -2 ie"7 e- 644 /eixi 94 Adee 57X- -k lipn,.. -12..-- Iv. .syr, livittc 5is/8„,„_. /11.tit-i4e.r-ele;77 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspe or: "1/1,c--3 Date: 6/3 II i Hrs.: A S— $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:goriecdr,e.‘. V Inspection: It'-' ..'* 1 *..5 p L.)12 -col Address: Suite#: VS AteE Contact Person: Permits: Special Instructions: Phone No.: IXApproved per applicable codes. Corrections required prior to approval. COMMENTS: tAidi ',71-7,-ir Ars Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: _ / (3 Date: 6/2-Z1/6 Hrs.: / , O $100.00 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 NSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 4( Sprinklers: Type of Inspection: Hood & Duct: Monitor: Address: ,J Suite #: 7ttO Alg Conta�son: Special Instructions: Phone No.: nApproved per applicable codes. NCorrections required prior to approval. COMMENTS: t--(--fti k_ Weider- Cifv,,c___ -1(-zf, C:1Ae_ --\--P.,,,,,m5 k, C....,_e-c.U_ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: t 3 Date: t5/ Z 2fl G Hrs.: it 6 r / n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit. PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Sprinklers: Type of In iony/O Address: Suite #: � ho / v(/ O Contact Per on: Special Instructions: Occupancy Type: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: Zoo /41.s / -� Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 1 1 Inspector: fj Date: Gr/ghL Hrs.: 2.. a $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Sprinklers: Type of Ins ctio : 'yr) 6 ve-✓ / Address: Suite #: VSe // 41k Air, Contact Per n: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspeao "7-ii 13 Date: 4/81/‘ Hrs.: Z.- 0 C...• - 1/ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER NSPECTION RECORD Qi /,-S -OSi Retain a copy with permit meg( PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Ty ' exer " 1� Sprinklers: a of Inspecti va dia Address:Contact Suite #: Ye0 6 Pers : Special Instructions: Phone No.: riApproved per applicable codes. orrections required prior to approval. COMMENTS: .•:;V;aij bfrej //eta& fre,1 eliNnA4IPPY2 ZeWV, ,itu% Nye 23 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: i Inspector: ste,_ fr/x6 3 Date: 5/7.51 /G Hrs.: (. Zj $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with it PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: # Type of Inspection: Address: Suite #: y60itf�' Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /&*l`eof /et( ‘41.ts.4--- 7 d 0/1,e 1,4 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: / Inspector.♦ �i 7 (7 Date: r72. -Jit S Hrs.: I. (j G / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER NSPECTION RECORD Retain a copy with {hermit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Sprinklers: Type of Inspection: 5P Address:Contact Suite #: t60 hfie Person: Special Instructions: Phone No.: Approved per applicable codes. \i'Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: : k ---?...,..4,.. A --(A etkcw,........4,440._ 7 c.v. waok---a--- (Alk.0.4 Occupancy Type: - OK_ -1,-.. kaebt L.....t.6 g-, c.,,-,4 1--,-;,- ----e„...._ ty,..,..4, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector• . Date: tek Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy wit it PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206 -575 - Project:// et) ,C4oehicte Type of Inspection: Address: ���) Suite #: v �Contact Person: Special Instructions: Permits: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4/211-ff 57Gf fnr !163 gAt4o ,sxplexA asif4/ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector. Date: rs.. . 00.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Word/Inspection Record Form.Doc 3/14/14 Zip: T.F.D. Form F.P. 113 TU'ILA FIRE MARSHAL'S OFISE Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshaltukwilawa.goy CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date 11 -74 -\gyp Permit Ck,lk — eCj.ei‘ Property Address 4tb0 A4NAChtur c'avrV..- 5 Suite # Cit% TUKWILA Zip Code ci2\o9 Name of Facilit\ InC) ,iC ejf Pair k E LLC, C p-NC)4Eo_ l Occupied as Dff\C,� (WO µ-O.JSE Owner or RepresentativeDo1/40 f�l�V�r6n Phone = 41. - 3qq$ Installing Company AC_,S \Q SC waxi ( Installing Contractor's Address 2.0. 60X. 3 101 Cit% t,htieN Phone 3(.t0 ^ tAqi to3Za Installer's Nance (PRINT) M.( �(�� Q S€Lv �'( S4GTENVIS License and "or Certificate At.ikQ,C(O General Contractor SPMAt Electrical Contractor SSE FACP Equipment Manufacturer Pp. .e . -4. Model = p200 This system has been installed. pre -tested and operates in accordance with the standards listed below and was inspected b\ Je, LG\it.\\ I a\t,\A, C-Oryl On (date) I1-21.= l(i Circle all that apply: and includes the devices listed on back. V NFP/-‘ 72. Chapter 1 2 -I 5 6 7 and or IFC SEC 907 NEPA 70. National Electrical Code. Article 760 Manufacturer's Instructions 1� Manufacturer's Instructions Other (specify) Tukwila Cit\ Ordinance Numbers 2050. 2051 UL Central Stati )n Monitor 0k\G,f on lvmk{,v- S. stem is monitored b\ A\a •trA W^rt..r `AC - SIGNED Date 11-1-7.---U, S\ stem Firmware: Installed version Checksum Date Initial program Installation Date Revisions and Reasons Programmed In, EQUIPMENT INSTALLED AND TESTED: Control Panel j of I Make/Model Qp 1-e..V PS! - b 14 (s'. S� Manual Station 'S of _ Make/Model c;1044,- A$$ - Smoke Detectors of Make/Model Heat Detectors of Make/Model Duct Detectors of Make/Model A/V Devices 10 4 ole 10 Make/Model yr,11.t1in '-eACor- ! PoR. I- PC44- Audio Devices of Make/Model Visual Devices �� of (3 Make/Model cj�A 1 Ste,_ Auto Door Release of Make/Model Trouble Indictors of Make/Model Batteries Readings Battery Full Load Charge Generator of Make/Model IIVAC Controls of Make/Model Fire Alarm Dialer of Make/Model Monitored by Annunciator of Make/Model Sprinkler System. (Fire Alarm connections only ) Water Flow 5‘‘.. of Make/Model Valve Tamper Sw . of Make/Model PIV of Make/Model Elec. Alarm Bell of Make/Model Automatic time Delay of Water Flow Alarm seconds. None Installed Do you meet audible/' isible requirements of \VAC 51-20. IFC SEC 907., and; or NFPA 72 Chapter 6? Yes No Test of alarm System on emergency power. satisfactory'' Yes No fest Witnessed b‘ R1Ci/NU✓d. (ON/ Title lELAmni Comments: Date 11- 21-1(0 Fire Alarm Certi4icate.doc Revised: 6:17 14 TFD FP Form #110 11/26/2014 16:11 3604384244 LACEY OPS /617 444 Andover W�,.�' " � �i �� • Pork Past, Tukwila, WA 9'8,1118 - Phnne 2,11&575-4407,1 Pic 20f 575-4439 ` C'C'Ol' = tDN.. filiE ALAM.* li*: Fire alarm System is ready for Fire D act t~p mea til stin& ailtiie�tte 1sult lux 1 tezminatirnt of the est ng andadCl`rf m7at s gibepik s d. Coliteitetrir ii itsylinsibla for supplying manpower for Final Acceptance Test, with iia -w y ed iw *Mew. Ti lit # Suite # PAGE 02/03 VV i Date b--lf Y City 1tJ, WILA Name of Facility Occupied as Owner or Representative ef Installing Company f- ' Installing Contractor's Address Phone 4 . 5 i~ — City _ / bone # (3 60) I/q/- 63 zo Installer's Name (PRINT) $t.7 [jv,JL4 License and/or Certificate General Contactor Electrical Contractor FACP Equipment Manufacturer This system has been ' , : •: 1; pre-, • • • and operates in accordance with the standards listed below and was inspected by On (elate) L- 11-N Circle all that apply: NFPA 72, Chapter 12 4 5 6 7 and/or IFC SBC 907 NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions Manufacturer's Instructions Other (specify)/ t/ Tukwila City Ordinance Numbers 2050, 2051 Model # and includes the devices listed on back. UL Central Station SIGNED Jr :unit system is monitored try A45 /? f paw System Firmware: Installed version Checksum _ Date Initial program Installation Date Revisions and Reasons Programmed by 11/26/2014 16:11 3604384244 EQUIPMENT INSTALLED AND TESTED.: }, LACEY OPS Control Panel of Iviaishviocial Manual Station — of Smoke Detectors — of Mikebei l Heat Demems — of 'Makcibtottell Duct Demos — of_ Meiod/Mal .. AN Devices i of MakeIMddel Audio Devices of Make/Model Visual Devices _ of Make/Model Auto Door Release i of Make/Model Trouble Indictors _ of_ l alce/Model Batteries Readings Battery I Z 1 q Full Load Charge Generator HVAC Controls Fire Alarm Dialer Monitored by Annunciator of of of Make/Model Make/Model Make/Model of Make/Model 0 Sprinkler System. (Fire Alarm connections only) Water Flow Sw. _ of Make/Model Valve Tamper Sw. of Maim/Model PN of _ Make/Model Elec. Alarm Bell of Make/Model Automatic time Delay of Water Flow Alarm seconds. None Installed Do you meet audible/visible requirements of WAC 51-2% IFC SEC 901., and/or NITA 72 Chapter 6? Yes No Test of mann System on emerge poi&er, satisfactory? Yes _r/ ,No Test Witnessed by /1 Title f C 4 Date -1/ %r Comments: eddinaire Alarm Cexifirate,doc Revised: 10/28/04 TMF'PFarm #110 PAGE 03/03 POTTER The Symbol of Protection PSN -64 Battery & Voltage Drop Calculations Model #: PSN -64 Panel ID: Project Name: Installed By: Designed By: Date: 480 ANDOVER PARK E WAREHOUSE TI Ace Fire & Security KLM 10/3/2016 Location: NEXT TO EXISTING FACP IN STAIRWA Standby Hours: Alarm Mins: Batt Efficiency %: NAC Source Voltage: 24 5 80% 20.4 Max Panel Current (amps): 6 User assumes all responsibility to ensure the quantities and current draw values in this worksheet are accurate prior to submittal. Qty Panel Part # Description Standby (amps) Each Total Alarm (amps) Each Total 1 PSN -64 NAC Power Expander 0.075 Panel Standby: 0.075 0.075 0.075 Panel Alarm: 0.075 0.075 NAC Circuits (See NAC Configuration below) Ckt Use Description Standby (amps) Total Alarm (amps) Total 1 Notification 2 Notification 3 4 AUX STROBES and HORN STROBES STROBES and HORN STROBES 0.00000 0.00000 0.00000 0.00000 0.00000 NAC Standby: 0.00000 NAC Alarm: 1.88700 1.68200 0.00000 0.00000 0.00000 3.56900 Battery Calculation Summary Standby (amps) Alarm (amps) Potter Electric Signal (C)2011 Panel Current: NAC Circuit Current: Total Standby: Standby Hours: AH Required: 0.07500 0.00000 0.07500 3.56900 0.075000 24 1.80 Total Alarm: Alarm Mins: AH Required: Total Combined Standby & Alarm AmpHours Required: Efficiency Factor: Required Battery AmpHours: Battery AmpHours Provided: 3.64400 5 0.31 2.11 80% 2.64 1 of 3 PSN -1000(E) Battery and Voltage Drop Calculation POTTER rS nt,,,rri ntrn�✓i NAC Circuit Configuration & Voltage Drop 480 ANDOVER PARK E 10/3/2016 NAC 1 MAX Circuit Current (amps): 3 Source Voltage Used (VDC): 20.4 414 Solid 3 STROBE 4 STROBE 1 HORN STROBE 3 HORN STROBE Usage: Notification 2.5 SS SR 75cd SS SR 95cd SS PC2R 30cd SS PC2R 95cd 466 Description: STROBES and HORN STROBES 2.330 1.887 Total Standby: 0.00000 16.00 16 0.158000 0.474000 0.181000 0.724000 0.107000 0.107000 0.194000 0.582000 Total Alarm: 1.88700 NAC 2 MAX Circuit Current (amps): 3 Source Voltage Used (VDC): 20.4 Usage: Notification Description: STROBES and HORN STROBES 414 Solid 2.5 460 2.300 1.682 16.53 16 3 STROBE 3 STROBE 1 STROBE 4 HORN STROBE 1 HORN STROBE Potter Electric Signal (C)2011 SS SR 15cd SS SR 30cd SS SR 95cd SS PC2R 95cd SS PC2R 135cd Total Standby: 0.00000 0.066000 0.094000 0.181000 0.194000 0.245000 Total Alarm: 0.198000 0.282000 0.181000 0.776000 0.245000 1.68200 2 of 3 PSN -1000(E) Battery and Voltage Drop Calculation NAC Circuit Configuration & Voltage Drop (coned) 480 ANDOVER PARK E 10/3/2016 NAC 3 MAX Circuit Current (amps): 3 Source Voltage Used (VDC): 20.4 Usage: Description: Wire Type #14 Solid Ohms/1000ft Length 1 -Way Actual Ohms Max Load (amps) Volts @ EOL Min Volts Req'd .5 0.000 0.000 20.40 16 Circuit Devices Qty Lookup Type Desc Standby (amps) Each Total Alarm (amps) Each Total User can add devices on the fly to these bottom 5 rows (No lookup function) Total Standby: 0.00000 Total Alarm: 0.00000 NAC 4 MAX Circuit Current (amps): 3 Source Voltage Used (VDC): 20.4 Wire Type #14 Solid Usage: j Description: Ohms/1000ft Length 1 -Way Actual Ohms Max Load (amps) Volts @ EOL Min Volts Req'd 2.5 0.000 0.000 20.40 16 Circuit Devices Qty Lookup Type Desc Standby (amps) Each Total Alarm (amps) Each Total • AUX Power MAX Circuit Current (amps): 3 Source Voltage Used (VDC): 20.4 Wire Type #14 Solid Usage: Description: Ohms/1000ft Length 1 -Way Actual Ohms Max Load (amps) Volts @ Last Device Min Volts Req'd 2.5 0.000 0.000 20.40 16 Circuit Devices Standby (amps) Qty Lookup Type Desc Each Total Alarm (amps) Each Total I User can add devices on the fly to these bottom 5 rows (No lookup function) User can add devices on the fly I to these bottom 5 rows (No lookup function) T..,..1 Cf....Al.... fl MAW T..f...l A 1-...... f1 IN%Mff • AUX Power MAX Circuit Current (amps): 3 Source Voltage Used (VDC): 20.4 Wire Type #14 Solid Usage: Description: Ohms/1000ft Length 1 -Way Actual Ohms Max Load (amps) Volts @ Last Device Min Volts Req'd 2.5 0.000 0.000 20.40 16 Circuit Devices Standby (amps) Qty Lookup Type Desc Each Total Alarm (amps) Each Total User can add devices on the fly to these bottom 5 rows (No lookup function) Total Standby: 0.00000 Total Alarm: 0.00000 Potter Electric Signal (C)2011 3 of 3 PSN -1000(E) Battery and Voltage Drop Calculation i'!POTTER Plus +` P200 Battery & Voltage Drop Calculations Project Name: 1480 Andover Office TI Standby Hours: 124 480 Andover Park E, Seattle, W Alarm Mins: 15 Installed By: IAce Fire & Security Batt Efficiency: i80% Designed By: I KLM SLC Type: I Class B Date: ! 3/10/2016 NAC Source Voltage: 120.4 Model #: P200 Panel ID: Location: Max Panel Current (amps): 5 User assumes all responsibility to ensure the quantities and current draw values in this worksheet are accurate prior to submittal. Qty FACP Part # Description Standby (amps) Each Total Alarm (amps) Each Total 1 P200 Analog Addressable FACP 0.130 Panel Standby: 0.130 0.130 0.220 Panel Alarm: 0.220 0.220 P -LINK (RS -485) Standby Alarm 1 UD -1000 I RA -6075 IRA -6500 I LED -16 ILED-16 ICA -6075 IPSN-1000(E) RLY-5 IRLY-5 1 DRV -50 I DRV -50 IFCB-1000 !FIB -1000 !SPG -1000 DACT LCD Annunciator LCD Annunciator LED Annunciator LED Annunciator LED Power* Class A Module Power Expander Relay Expander Relay Expander Power* LED Driver Module LED Driver Module LED Power* Fire Communications Bridge Fiber Interface Board Serial Parallel Gateway 0.016 0.020 0.020 0.025 0.015 0.012 0.015 0.025 0.010 0.025 0.010 0.025 0.030 0.040 0.016 0.023 0.025 0.050 0.025 0.210 0.044 0.015 0.035 0.135 0.025 0.215 0.025 0.030 0.040 0.023 (Maximum current draw on P -Link limited to 1 Amp) P -LINK Standby: *Only enter quantity if PLINK power is being used to power device 0.016 P -LINK Alarm: 0.023 SLC Devices Standby Alarm 1 IPSA I PSHA RHA 'FHA IDDA 1 IAPS-SA/APS-DA IMCM 5 !SCM -4 DCM-4 3 ITRM-4 I CIZM-4 * MOM -4 * IARB * IASB * ISCI ** AIB ** :SCI/AIB Class B ** Analog Photo Smoke Analog Photo Smoke/Heat Analog Rate of Rise Heat Analog Fixed Temp Heat Addressable Duct Detector Addressable Pull Station Single/Dual Action Mini Contact Input Module Single Contact Input Module Dual Contact Input Module Twin Relay Output Module Conventional Zone Input Mod Monitored Output Module Detector Base w/Relay Detector Base w/Sounder Short Circuit Isolator (Class A) Detector Base w/Isolator (Class A) Current Draw from Install Manual SLC Loop Alarm LED Current 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.001625 0.000975 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.000325 0.001000 0.001000 0.001000 0.001000 0.001000 0.000325 0.000325 0.002340 0.002340 0.000000 0.000000 0.027000 0.000325 0.000325 0.005000 0.003000 0.027000 Requires Aux Power (Configure Below) See the installation manual for special considerations when installing AIB, SCI devices on Class B loops. Potter Electric Signal (C)2011 SLC Standby: 0.003250 SLC Alarm: 0.035650 1 of 4 P200 Battery and Voltage Drop Calculation NAC Circuits (See NAC Configuration below) Ckt Use Description Standby (amps) Total Alarm (amps) Total 1 Notification 2 Notification 1st FI Horn/Strobes-Strobes 2nd FI Horn/Strobes-Strobes NAC Standby: 0.00000 0.00000 0.00000 NAC Alarm: 1.60400 1.08400 2.68800 I/O Circuits (See I/O Configuration below) Ckt Use Description Standby (amps) Total Alarm (amps) Total 1 Unused 2 I/O Standby: 0.00000 0.00000 0.00000 I/O Alarm: 0.00000 0.00000 0.00000 Battery Calculation Summary Standby (amps) Alarm (amps) SLC Loop Type: Class B Point Capacity Needed: 10 Point Capacity Actual: 75 Panel Current: P -Link Current: SLC Device Current: NAC Circuit Current: I/O Circuit Current: Total Standby: Standby Hours: AH Required: 0.13000 0.01600 0.00325 0.00000 0.00000 0.22000 0.02300 0.03565 2.68800 0.00000 0.149250 24 3.59 Total Alarm: Alarm Mins: AH Required: Total Combined Standby & Alarm AmpHours Required: Efficiency Factor: Required Battery AmpHours: Battery AmpHours Provided: 2.96665 5 0.25 3.84 80% 4.80 Note: The cabinet will house two 8 AH or 18 AH batteries. The charging circuit is rated for up to two 55 AH batteries. Potter Electric Signal (C)2011 2 of 4 P200 Battery and Voltage Drop Calculation POTEIR ;rc n. n.,. 0'3.+0100;.. NAC Circuit Configuration & Voltage Drop 480 Andover Office TI 3/10/2016 NAC 1 MAX Circuit Current (amps): 3 Source Voltage Used (VDC): 20.4 Usage: I Notification #14 Solid 2.5 242'-9" Description: I 1st FI Horn/Strobes-Strobes #VALUE! 1.604 #VALUE! 16 1 IOutdoor H/S 110cd SS P2RK 0.212000 0.212000 10 IStrobe 15cd 3 IH/S 15cd i SS SCR ISS SCR 0.066000 0.660000 0.079000 0.237000 1 IH/S 30cd ISS SCR 0.107000 0.107000 2 I H/S 95cd !SS SCR 0.194000 0.388000 Total Standby: 0.00000 Total Alarm: 1.60400 NAC 2 MAX Circuit Current (amps): 3 Source Voltage Used (VDC): 20.4 Usage: I Notification Description: 2nd FI Horn/Strobes-Strobes #14 Solid 2.5 196'-0" #VALUE! 1.084 #VALUE! 16 1 1H/S 75cd I SS SCR 8 IStrobe 15cd ISS SCR 0.176000 0.176000 0.066000 0.528000 1 IH/S 15cd ISS SCR 0.079000 0.079000 1 IH/S 30cd ISS SCR 0.107000 0.107000 1 I H/S 95cd 1 SS SCR 0.194000 0.194000 Total Standby: 0.00000 Total Alarm: 1.08400 Potter Electric Signal (C)2011 3 of 4 P200 Battery and Voltage Drop Calculation POTTER '•wr ire J'/r^:1 r: HoreeG: I/O Circuit Configuration & Voltage Drop 480 Andover Office TI 3/10/2016 I/O 1 MAX Circuit Current (amps): 1 Source Voltage Used (VDC): 20.4 Usage:lUnused Description: #14 Solid 2.5 0.000 0.000 20.40 16 I(No lookup function) Total Standby: 0.00000 Total Alarm: 0.00000 I/O 2 MAX Circuit Current (amps): 1 Source Voltage Used (VDC): 20.4 Usage: Description: I User can add devices on the fly to these bottom 5 rows (No lookup function) Total Standby: 0.00000 Total Alarm: 0.00000 Potter Electric Signal (C)2011 4 of 4 P200 Battery and Voltage Drop Calculation FIRE SPRINKLERS INC. 1524 45th St E, SUITE 102 SUMNER,WA 98390 HYDRAULIC CALCULATIONS FOR HEATCON 480 ANDOVER PARK EAST TUKWILA, WA 98188 REMOTE AREA 1 FILE NUMBER: 3870 DATE: 7/31/16 -DESIGN DATA - OCCUPANCY CLASSIFICATION: NFPA 13 (ORDINARY HAZARD) DENSITY: 0.15 gpm/sq. ft. AREA OF APPLICATION: 1585 sq. ft. COVERAGE PER SPRINKLER: 256 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 8 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 322.6 gpm TOTAL WATER REQUIRED (including hose): 572.6 gpm FLOW AND PRESSURE (@ BOR): 422.6 gpm @ 93.6 psi SPRINKLER ORIFICE SIZE: 11.2=K SPRINKLER TYPE: VK534 SPRINKLER TEMP: 155° NAME OF CONTRACTOR: FIRE SPRINKLERS INC DESIGN/LAYOUT BY: MATTHEW RAPOZO AUTHORITY HAVING JURISDICTION: CITY OF TUKWILA CONTRACTOR CERTIFICATION NUMBER: FIRESI*988RJ CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE,.3$Qj, HRS SYSTEMS, INC. WASHINGTON STATE COITIVICAT! OF COMPETENCY I IIRE PROTECTION SPRINKLER SYSTEMS I 1 I David Lisiecki 1470-0793-C Level3 pFire Spank'Incorporated FIRESI Data a_wa award MMWRIM 111111111111111 1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 T DATE: 8/4/2016DESIGN\03-CALCULATIONS\01-HYDRAULIC\3870 - CALCULATIONS.SDF JOB TITLE: Heatcon WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL, TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) BOR 140.0 130.0 2000.0 139.0 572.6 93.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 572.6 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 150.0 GPM OTHER HOSE STREAM ALLOWANCES 100.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 322.6 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) S1 12.0 K=11.20 11.8 38.4 S2 12.0 K=11.20 12.0 38.9 S3 12.0 K=11.20 12.0 38.9 S4 12.0 K=11.20 12.3 39.3 S5 12.0 K=11.20 12.7 40.0 S6 12.0 K=11.20 13.0 40.4 S7 12.0 K=11.20 14.9 43.2 S8 12.0 K=11.20 15.2 43.6 1 13.0 26.1 2 13.0 26.7 3 13.0 26.7 4 13.0 27.3 5 13.0 28.2 6 13.0 28.8 7 13.0 32.8 8 13.0 33.5 A 13.0 29.4 B 13.0 30.0 C 13.0 31.7 D 13.0 - - - - 36.7 E 21.0 HOSE STREAM 84.4 50.0 F 20.0 HOSE STREAM 86.0 50.0 TOR 20.0 - - - - 86.1 BOR 3.0 SOURCE 93.6 422.6 t SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/4/2016DESIGN\03-CALCULATIONS\01-HYDRAULIC\3870 - CALCULATIONS.SDF JOB TITLE: Heatcon PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -38.4 1.049 PL 29.00 PF 14.8 S1 12.0 11.2 11.8 38.4 14.3 120 FTG T PE -0.4 1 13.0 0.0 26.1 0.0 0.435 TL 34.00 PV Pipe: 2 -38.9 1.049 PL 29.00 PF 15.1 S2 12.0 11.2 12.0 38.9 14.4 120 FTG T PE -0.4 2 13.0 0.0 26.7 0.0 0.445 TL 34.00 PV Pipe: 3 -38.9 1.049 PL 29.00 PF 15.1 S3 12.0 11.2 12.0 38.9 14.4 120 FTG T PE -0.4 3 13.0 0.0 26.7 0.0 0.445 TL 34.00 PV Pipe: 4 -39.3 1.049 PL 29.00 PF 15.5 S4 12.0 11.2 12.3 39.3 14.6 120 FTG T PE -0.4 4 13.0 0.0 27.3 0.0 0.455 TL 34.00 PV Pipe: 5 -40.0 1.049 PL 29.00 PF 15.9 S5 12.0 11.2 12.7 40.0 14.8 120 FTG T PE -0.4 5 13.0 0.0 28.2 0.0 0.469 TL 34.00 PV Pipe: 6 -40.4 1.049 PL 29.00 PF 16.3 S6 12.0 11.2 13.0 40.4 15.0 120 FTG T PE -0.4 6 13.0 0.0 28.8 0.0 0.478 TL 34.00 PV Pipe: 7 -43.2 1.049 PL 29.00 PF 18.4 S7 12.0 11.2 14.9 43.2 16.0 120 FTG T PE -0.4 7 13.0 0.0 32.8 0.0 0.540 TL 34.00 PV Pipe: 8 -43.6 1.049 PL 29.00 PF 18.7 S8 12.0 11.2 15.2 43.6 16.2 120 FTG T PE -0.4 8 13.0 0.0 33.5 0.0 0.551 TL 34.00 PV Pipe: 14 -38.4 1.728 PL 16.00 PF 0.6 1 13.0 0.0 26.1 0.0 5.3 120 FTG ---- PE 0.0 2 13.0 0.0 26.7 0.0 0.038 TL 16.00 PV Pipe: 15 -77.3 1.728 PL 7.58 PF 2.6 2 13.0 0.0 26.7 0.0 10.6 120 FTG T PE 0.0 A 13.0 0.0 29.4 0.0 0.139 TL 18.87 PV Pipe: 16 -38.9 1.728 PL 16.00 PF 0.6 3 13.0 0.0 26.7 0.0 5.3 120 FTG ---- PE 0.0 4 13.0 0.0 27.3 0.0 0.039 TL 16.00 PV Pipe: 17 -78.2 1.728 PL 7.58 PF 2.7 4 13.0 0.0 27.3 0.0 10.7 120 FTG T PE 0.0 B 13.0 0.0 30.0 0.0 0.143 TL 18.87 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 ' DATE: 8/4/2016DESIGN\03-CALCULATIONS\01-HYDRAULIC\3870 - CALCULATIONS.SDF JOB TITLE: Heatcon PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 18 -40.0 1.728 PL 14.50 PF 0.6 5 13.0 0.0 28.2 0.0 5.5 120 FTG ---- PE 0.0 6 13.0 0.0 28.8 0.0 0.041 TL 14.50 PV Pipe: 19 -80.4 1.728 PL 7.58 PF 2.8 6 13.0 0.0 28.8 0.0 11.0 120 FTG T PE 0.0 C 13.0 0.0 31.7 0.0 0.150 TL 18.87 PV Pipe: 20 -43.2 1.728 PL 14.50 PF 0.7 7 13.0 0.0 32.8 0.0 5.9 120 FTG ---- PE 0.0 8 13.0 0.0 33.5 0.0 0.047 TL 14.50 PV Pipe: 21 -86.8 1.728 PL 7.58 PF 3.3 8 13.0 0.0 33.5 0.0 11.9 120 FTG T PE 0.0 D 13.0 0.0 36.7 0.0 0.173 TL 18.87 PV Pipe: 27 -77.3 2.203 PL 16.00 PF 0.7 A 13.0 0.0 29.4 0.0 6.5 120 FTG ---- PE 0.0 B 13.0 0.0 30.0 0.0 0.043 TL 16.00 PV Pipe: 28 -155.4 2.203 PL 10.50 PF 1.6 B 13.0 0.0 30.0 0.0 13.1 120 FTG ---- PE 0.0 C 13.0 0.0 31.7 0.0 0.156 TL 10.50 PV Pipe: 29 -235.8 2.203 PL 15.00 PF 5.1 C 13.0 0.0 31.7 0.0 19.9 120 FTG ---- PE 0.0 D 13.0 0.0 36.7 0.0 0.337 TL 15.00 PV Pipe: 30 -322.6 2.203 PL 54.96 PF 51.1 D 13.0 0.0 36.7 0.0 27.2 120 FTG T4L PE -3.5 E 21.0 H.S. 84.4 50.0 0.601 TL 84.97 PV Pipe: 31 -372.6 6.065 PL 180.79 PF 1.2 E 21.0 H.S. 84.4 50.0 4.1 120 FTG TL PE 0.4 F 20.0 H.S. 86.0 50.0 0.006 TL 219.79 PV Pipe: 32 -422.6 8.071 PL 1.00 PF 0.0 F 20.0 H.S. 86.0 50.0 2.7 120 FTG L PE 0.0 TOR 20.0 0.0 86.1 0.0 0.002 TL 14.73 PV Pipe: 33 -422.6 8.071 PL 17.00 PF 0.2 TOR 20.0 0.0 86.1 0.0 2.7 120 FTG TGA PE 7.4 BOR 3.0 SRCE 93.6 (N/A) 0.002 TL 90.93 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 8/4/2016DESIGN\03-CALCULATIONS\01-HYDRAULIC\3870 - CALCULATIONS.SDF JOB TITLE: Heatcon NOTES (HASS): (1) Calculations were performed by the HASS 8.6 computer program in accordance with NFPA13 (2016) under license no. 38011601 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.098 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 27.2 ft/sec at pipe 30. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node BOR under full flow conditions is 138.75 psi compared to the minimum required pressure of 20.00 psi. (6) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkV1v BfyVly GatV1v AlmChk DPV1v NPTee 1.728 5.64 11.29 2.82 12.70 8.47 1.41 14.11 14.11 11.29 2.203 6.82 13.64 4.09 15.00 8.18 1.36 13.64 13.64 13.64 8.071 19.01 36.96 13.73 47.53 12.67 4.22 32.74 32.74 36.96 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 6.065 14.00 30.00 9.00 32.00 10.00 3.00 28.00 28.00 30.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 8/4/2016DESIGN\03-CALCULATIONS\01-HYDRAULIC\3870 - CALCULATIONS.SDF JOB TITLE: Heatcon 2000.0 gpm I m • m a) a] 3.4 a) a 5 I a s u o, a v 01 a 01 1 N )4 • a) N ro a) [� O N A N 5 mi..0 MN c a) a) m ul a) 0 PM, a) NJ a u .a a) M a -O m O a co m H ao H ao 422.6 gpm Available 1-4 %/ Demand Curve a) 0 u 0 0 co J-) 0 a) .0 a) 5 ro O a) r+ — m U >, > am U a uz W 0 0 o O (0 O N O O O O O O 0 • O O O O O O to V' N O 00 l0 O rC O 0 w a s w cn m D a w -- a c0 -H -- O ko r -I N r -I • , a SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 8/4/2016DESIGN\03-CALCULATIONS\01-HYDRAULIC\3870 - CALCULATIONS.SDF JOB TITLE: Heatcon WATER SUPPLY CURVE 144+ *\\\\\\\\\\\\\\\\ 1 0 \\\\\\\\\\\\\\\\ 1 \\\\\\\\\\\\\\\\ 132+ \\\\\\\\\\\\\\\\ 1 130.0 psi @ 2000 gpm-> 1 Flow Test Point 1 120+ 1 1 1 108+ 1 1 1 P 96+ R 1 X E 1 S 1 S 84+ U 1 R 1 E 1 72+ ( 1 P 1 s 1 I 60+ ) 1 1 1 48+ 1 24+ LEGEND 1 1 X = Required Water Supply 1 93.60 psi @ 572.6 gpm 12+ 1 0 = Available Water Supply 1 139.01 psi @ 572.6 gpm 0++-+---+----+ + + + + + + 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) March 19, 2016 David J. Baerman, Fire Protection Consultant 23208 Florence Acres Rd Monroe, WA 98272 Fire Sprinklers Inc. 1524 45th Street E. — Suite 102 Sumner, WA 98390 Attention: Dave Lisiecki, Design Manager Subject: Heatcon 480 Andover Park East Tukwila, WA Dear Mr. Lisiecki: Thank you for the opportunity to review your sprinlder plans for this project. Please note: This review is advisory only. Final approval is up to the authority having jurisdiction. After completing my review, I have the following comments: This project is a tenant improvement in the office areas of an existing sprinklered building. Work areas are on the first and second floors. The work includes adding and relocating pendent and upright sprinklers, and minor piping changes to accommodate a new stairwell. The design notes say that this system is designed for Ordinary Hazard occupancy. However, there is a large office in the northeast corner of the first floor and one above it on the second floor in which the sprinklers are over -spaced for Ordinary Hazard. They are acceptable for Light Hazard, which this appears to be. In a conversation with Brett Morrison of your company on March 17t, I asked a couple of questions about the design. The first was about the flexible drops and the fact that they have more friction loss than rigid piping. He said that with the high pressure of this water supply (148 psi static and 122 psi residual), the flex drops should not be a problem. I agree. The second question was about the 155 -degree rating of the new upright sprinlder heads in the blind space above the second floor ceiling. He said that the blind space is considered ventilated. If so, these heads comply with Table 8.3.2.5 (b) of NFPA 13 (2010 Edition). Mr. Morrison also said that the existing uprights are 155 -degree rated. Please include this letter with your submittal to the authorities, Sincerely, David J. Baerman, P.E. EXPIRES 4 / 9 / 7 GLU-LAM OR BEAM MODEL #GST 20 ALL THREAD ROD HANGER RING SAMMY SUPERSCREW HANGER TYPE S NTS GLU-LAM OR BEAM �-- MODEL #SWG 20 ALL THREAD ROD HANGER RING SAMMY SIDEWINDER HANGER TYPE SW NTS MECH. TEE INTO (E) 2" BRANCH LINE 1" SCH 40 DROP 1 x SHO NIPPLE 48" FLEXHEAD CEILING BRACKET IV//_.Y'V/r/i V/fH////HL//fHN/YH///YN///YNIV//H/// \t�R1 1/2" SSP FLEX DROP NTS DROP PENDENT DOWN TO NEW GRID UPRIGHTS TO REMAIN (TYP) OFFICE — I WAREHOUSE WAREHOUSE EXISTING UPRIGHTS TO REMAIN BREAK ROOM • WAREHOUSE SERVER r-, FILES R i OFFICE e- R R R QA R OFFICE R OFFICE OFFICE OFFICE R r 1.T. OFFICE OFFICE -0 R r WAREHOUSE EXISTING SPRINKLERS TO REMAIN - FIRE SPRINKLER PLAN - LEVEL 2 SCALE: 1/8" =1'-0" WAREHOUSE 5.7%: ////////� —% ii/ ISTORAGE; 15.5 ry OFFICE WOMEN MEN WOMEN R r it �1i } fir----^---r� 0 EXISTING SPRINKLERS TO REMAIN 7 N EXISTING SPRINKLERS TO REMAIN WAREHOUSE • 4 4 fi EXISTING SPRINKLERS TO REMAIN -----------------------r r EXISTING SPRINKLERS TO REMAIN FIRE SPRINKLER PLAN - LEVEL 1 SCALE: 1 /8" =1'-0" SCOPE OF WORK: ADD AND RELOCATE UPRIGHT AND PENDENT SPRINKLERS AS REQUIRED FOR WALL AND CEILING MODIFICATIONS ABOVE AND BELOW THE EXISTING OFFICE MEZZANINE. GENERAL NOTES: 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 2. PIPING DIMENSIONS ARE CUT LENGTH EXCEPT RISER DIMENSIONS AND MAINS, SHOWN THUSLY (1-6), WHICH ARE END TO END. 3. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13 (2013). 4. PIPING SHALL BE IN ACCORDANCE WITH NFPA #13 (2013). 5. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED, SHALL BE IN ACCORDANCE WITH NFPA #13 (2013). 6. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 7. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 8. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. DESIGN NOTES: 1. DESIGN AND SPRINKLER SPACING TO BE PER NFPA #13 ORDINARY HAZARD. 2. PLAN SUBMITTAL TO AND APPROVAL BY THE CITY OF TUKWILA. 3. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY FSI. 4. TESTING PER NFPA #13 AND THE CITY OF TUKWILA. FIELD NOTES: 1. ALL NEW PIPE TO BE BLACK, SCHEDULE 40 WITH BLACK, DUCTILE IRON THREADED FITTINGS. 2. SPRINKLERS IN ACT TYPE CEILINGS TO BE INSTALLED ON 1" X'/%" X 48" FLEXHEADS. 3. SPRINKLERS ARE NOT REQUIRED TO BE LOCATED IN THE CENTER OF THE CEILING TILES. 4. ARMOVERS LONGER THAN 2'-0" SHALL HAVE A HANGER. 5. TYPICAL HANGER TO BE A SAMMY SIDEWINDER (UNLESS NOTED OTHERWISE). 6. MAX SQ FT PER SPRINKLER = 130 SQ FT. WALL LEGEND: - EXISTING WALL CONSTRUCTION SPRINKLER PIPE LEGEND: = EXISTING SPRINKLER PIPE = NEW SPRINKLER PIPE = NEW FLEXIBLE SPRINKLER DROP SPRINKLER LEGEND: = EXISTING SPRINKLER = EXISTING SPRINKLER = EXISTING UPRIGHT AND PENDENT ®R = • RELOCATED SPRINKLER OA = • ADD NEW SPRINKLER OA = • ADD NEW UPRIGHT = DEMO & PLUG EXISTING PENDENT SPRINKLER d = DEMO & PLUG EXISTING UPRIGHT SPRINKLER i ' a A Pc Ti3.:.Se piens h wv tf-fef) "rV,_ r tS=n / ) Fre .: t iticn City \r.. li3FiO ).5 {�� - ._ •'sd, i��.•r�rii - - � r1 :.�+u ' .. ride1 _ - .- - OFFICES ; WAREHOUSE { AREA OF WORK `fir•` :5,�';r.^ rtP�i.•;_-.. - .�-r'$i�i i:. __ -;r \ �. S aftPr Find l ,7 to field ct st a!?:, inspect cn b r -e � T ukvw! , # ,: ;::C_. Bureau. -TUKWILA FIRE CEAARTS'IFIf Plec.st �, a71:1205-575-4-41.07 and giv th - Fire Pqrrnit No. l4- -o05 downr .... ,-; _._j r - I EXPIRES 4791S% ALAS Lr A -rt -A Ci -k t LIQ TT R VICINITY MAP SCALE: NTS WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS David Usiecki 1470-0793-C Level 3 Fire Sprinklers Incorporated FIRES!_ ZZ' E Signature Date Csssasssusesssssssssssie 'Iowa■ sI Z O DESCRIPTION >- co w 0 w Ct DRAWING SYMBOLS - WELDED PIPE TAG w Z w ¢2 CO W N Z a_i aces w Z J I- CC w za0 ( 00 0) 1- 0 0 w O O j cc CC 0 ws- C.DO OV Of= w U wz �z Za CO COa 0a 2U X: LULL! U) w C7 aw i ov cc...)V')avi - HYDRAULIC NODE HANGER LEGEND SAMMY SUPER SCREW (GST20) SAMMY SIDEWINDER (SWG20) SPRINKLER LEGEND 0 M ti CO O >- d O Z 0 w 5 O 2 c U z L.L w 5 O 0 (n 0_ 2 w in LCT 0 0 LL m J O 5 • O w 0 O 5 Cr, > LL 11 5 0 O SPRINKLER TYPE QR STANDARD SPRAY PENDENT QR STANDARD SPRAY UPRIGHT TOTAL THIS SHEET Z 0 U WT 00 0) Lf) CO N LC) N 0 C>� 0 DD C 0 :103POi!d :HAIM 10172I1N00 WA CL# FIRESI*988R w z 0 N w 0 w 0 0 CO N 0 au IL CO - 0 T L) 0 CL -..zt`' - .- p Without Comments Ps ricitP(.1 Re. -4 o P Me Attached letter `rh ? plans .. ,sewed by The.Tui valla Fire ..4nr*Yj?rico with current Citi Bjr :r; errors and y yl?1a_" ,13y of adopted ,r Ior he after a ;r er..;t-. f t approval. p'%„ti,_TeSJ�V• tai - }ii Tr..e 1 ukwlla r =.` )tevenc;,' - ate:3-3)--b. 5y: _;;d 17-3 and inspection by `o6-5 5-3:37 :ted f c:'y t� �}3s'`39'3 re 3i=..s • rco-r-ot03 ;..12;i4411 �C �A • NO ICF A complete, signed, Tukwila Fire Department Pre-test • r-ilist Dreesented to the 1n ,,-:•actor orior to ccrr m i em ?- .t oF acceptance arr:1 Fire Alarm anJ'. • v1`on Failu7 : _. _ .st . i'1 . -c. uft Re-_ Fee d r -c; FIRST FLOOR FIRE ALARM PLAN 0' 4' 8' 16' SCALE: 1/5" = I ' - 0° Jonathan Olson NICET #40743 Fire Alarm Systems Level ill SYMBOL LEGEND ALARM CENTER, INC. FIRE ALARM CONTROL UNIT 1 FACU FAX: (360 435-4244 18 GAUGE 2 CONDUCTOR - FPLR MANUAL PULL STATION 1 F {� WA1�.EHOUSE TO WAREHOUSE TO WAREHOU E TQ WAREHOUSE 0 MONITOR MODULE TO WAREHOUSE 0 ff.] WALL MOUNTED HORN/STROBE 2 ► $4 CEILING MOUNTED HORN/STROBE 10 ® CEILING MOUNTED STROBE 18 a FIRE ALARM POWER SUPPLY I ;if WP WEATHERPROOF 1 XXcd CANDELA RATING OF STROBE LIGHT 1 SHIPPING t STAIR # # }i UTILITY! `, (I !I 11 II j �_ OFFICE WOM 1 i i M ' 3 ; ! 1 06 -- +} -- ; 1 ;0: --� € �' M 'tml �t"-- .E-- _�.. j i t } 331 fEa �A 1l. �� I i;ii �� ,L.-- 01scd is : { BREAK I€ � � I T � -� w. ►0. no Sprinkles. it - i d ROOM • ,--11 y I . `.{, it d I V OMEr MEd 3 B 1 s —mo i ; ► • . 1,c ® - ; ; 95cd s � l 1 , 11 ,• 1 O ICE L ; (; 1 �� ; t_ B 105,} !1 1, _ iI B EXISTING ' 1; STAIR; #' STORAGE 1 t (i� 1)OPEN is11 !l; ( A IL OFFICE OFFICE Ul 11 ` ,.. 104 102 IScd 1 15cd li . B i---' OPEC- i ' I t 1IgP- Ls cd B ` ► 0. OFFICE # I 1 ® i 3, ;t l 1.7 ji r. rte- ` iil ; ?""1 t , y�3 1? 31 x 1 ISS; 82 I O ' a1=FICE �� CONFE2ECONFERENCE, 'ECEPTION OFI'!CE OFFICE j ; 0 15c ; 1 1 1 1 6 103 l 1 0 1 1 1 9 i` 118 ....015cd II! 52 1 ; t S B EXISTING i lscd OFFICE FL— ii 1 I I 1 7 i1 1 A 1 A 1 !, 15cd ' TI1 I ;H 132 2 I YI i1 i j t I 1 X f . - --__-.__ m._..,...1, - —u --i_ I wp 110cd FIRST FLOOR FIRE ALARM PLAN 0' 4' 8' 16' SCALE: 1/5" = I ' - 0° Jonathan Olson NICET #40743 Fire Alarm Systems Level ill SYMBOL LEGEND ALARM CENTER, INC. FIRE ALARM CONTROL UNIT 1 FACU FAX: (360 435-4244 18 GAUGE 2 CONDUCTOR - FPLR MANUAL PULL STATION 1 F C Q PHOTOELECTRIC SMOKE DETECTOR # = CIRCUIT NUMBER 0 MONITOR MODULE 3 ff.] WALL MOUNTED HORN/STROBE 2 ► $4 CEILING MOUNTED HORN/STROBE 10 ® CEILING MOUNTED STROBE 18 a FIRE ALARM POWER SUPPLY 2 WP WEATHERPROOF 1 XXcd CANDELA RATING OF STROBE LIGHT 1 BUILDING DATA ADDRESS: PARCEL #: AREA: TYPE OF CONST: OCCUPANCY: 480 Andover Park E Tukwila, WA 98155 2623049093 1 6,57 7 sq. ft. OFFICE SPACE B MONITORING SERVICE PROVIDED BY: ALARM CENTER, INC. PO BOX 3407 LACEY, WA 98509-3407 PHONE: (800) 238-9I 26 FAX: (360 435-4244 WIRE LEGEND WIRE DESCRIPTION TYPE A 5LC 18 GAUGE 2 CONDUCTOR - FPLR 5 NAC CIRCUIT 14 GAUGE 2 CONDUCTOR - FPLR C NAC CIRCUIT 14 GAUGE 2 CONDUCTOR - FPLR # = CIRCUIT NUMBER 2 = OUT $ BACK CIRCUIT, DOUBLE NUMBER OF CONDUCTORS VICINITY MAP PAID `..i.� LL- 1 ,,13121 , 11IRC1nhIl rIr)r-- /25''24--o — 0 0. a) CO 0 N 1- 0 M 0 0 v c V E iv as 1065F-40305 1065F-40305 Andover Office T z J a <1 a) 0 0 N 1— J 0 45 a) File Name: DWG Name: ea 0 0 • L 00 .co cu coleo a3Q 0 Q O u. 110 as> O F— Q ._ = to ?� moo Qu. z U co . a Sheet Number FA.1 1of1 S 00 z9 0 SECOND FLOOR MRE ALARM PLAN 0' 4' 8' I6' SCALE: 1/5" = 1 ' - 0" Jonathan Olson NICET #40743 Fire Alarm Systems Level 111 SYMBOL LEGEND ALARM CENTER, INC. FIRE ALARM CONTROL UNIT 1 • € PAX: (360 438-4244 18 GAUGE 2 CONDUCTOR - FPLR I F C II STAIR #1 PHOTOELECTRIC SMOKE DETECTOR 1 OFFICE 3 M BREAK l WALL MOUNTED HORN/STROBE 2 ►€4 CEILING MOUNTED HORN/STROBE I0 ® CEILING MOUNTED STROBE 8 206 I rig, WEATHERPROOF ROOM C CANDELA RATING OF STROBE LIGHT • I . :,1,, = 207 75cd , 1 SERVER if' FILES ' 0 1; 4 II�I:� • ►0' ( '' 1 210 jj 2 1 1 1 !{{•{{ n ii I 1d .7W 5c j 1 !I so'i.j it a } DN 111f ` O H I /oilii'---... 1 11110 ' I l i ll i OFFI-E �C '' 20.5 !! C rim !t Cl l cd 1- .,� 'e 4 i- W ��ti ,- `C2 c\ 11 ® U, !• I `7 2 8 _ ® a v OFFICE C2 C I EXISTING � � = 211 1: `• . 1 '; m MEN i OFFICE OFFICE ° 209 '^-J 7!/GtI 1r l I } I0 204 Ii ti r -' ♦ U A�� . 1 � ► • : ® ♦ \ 1l OFFICE 1! OPEN l I, OFFICE Il C 213 L, l 201 9j i r; l ® 5 - F. OFFICE t'` gS"'/ ( 203 � `' ars 1 i\J, J � 3I 1.T. EXISTING XISTIs dG 1 I { ► OFFICE �.� 202 C2 1.�d WORK!! O -CA E Roo��w1 NV 2 I o l i 1 'Ib I 2 1 5 I i 7 s! If 1 IHH' 1 C'5TI\IG1 -- I STAIR I I �- --- ;( 1 1 I± M ,Q 00 z9 0 SECOND FLOOR MRE ALARM PLAN 0' 4' 8' I6' SCALE: 1/5" = 1 ' - 0" Jonathan Olson NICET #40743 Fire Alarm Systems Level 111 SYMBOL LEGEND ALARM CENTER, INC. FIRE ALARM CONTROL UNIT 1 FACU PAX: (360 438-4244 18 GAUGE 2 CONDUCTOR - FPLR MANUAL PULL STATION I F C Q PHOTOELECTRIC SMOKE DETECTOR 1 MONITOR MODULE 3 M ffl WALL MOUNTED HORN/STROBE 2 ►€4 CEILING MOUNTED HORN/STROBE I0 ® CEILING MOUNTED STROBE 8 FIRE ALARM POWER SUPPLY 2 WP WEATHERPROOF 1 xxcd CANDELA RATING OF STROBE LIGHT I BUILDING DATA ADDRESS: PARCEL #: AREA: TYPE OF CONST: OCCUPANCY: 480 Andover Park E Tukwila, WA 98185 2623049093 1 6, 577 sq. ft. OFFICE SPACE B MONITORING SERVICE PROVIDED BY: ALARM CENTER, INC. PO BOX 3407 LACEY, WA 98509-3407 PHONE: (800) 238-9 126 PAX: (360 438-4244 WIRE LEGEND WIRE DESCRIPTION TYPE A SLC 18 GAUGE 2 CONDUCTOR - FPLR B NAC CIRCUIT 14 GAUGE 2 CONDUCTOR - FPLR C NAC CIRCUIT 14 GAUGE 2 CONDUCTOR - FPLR # = CIRCUIT NUMBER 2 = OUT $ BACK CIRCUIT, DOUBLE NUMBER OF CONDUCTORS VICINITY MAP M CO M LC) CO C4) al in CPc14 la 0• T- - V 0Wg m OQoO afoot) A DIVISION OF ALARM CENTER, INC. 0 0. 0 0 0 co 0 0 0 -J kara@alarmcenterinc.com 1065F-40305 1065F-40305 Andover Office T 3 0 1 0 MOM 0 0 File Name: DWG Name: 0 111.1 s- 03 00 �— OCctso0 0 0fIr o gOL.M O o� -43 cIS > Z = O Q '— § o = V o � W o 0 E z 0 0 L a Sheet Number FA.2 2of2 ACE FIRE & SECURITY SYSTEMS A DIVISION OF ALARM CENTER, INC. 06/11/2013 CITY OF TUKWILA FIRE 444 ANDOVER PARK E TUKWILA, WA 98188 ATTN.: AL METZLER RE: SWADDLE DESIGN'S 480 ANDOVER PARK E TUKWILA, WA 98188 ii/ !Op ACCEPTED 0 Without Comments 'gr*As Noted in Red a Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City :andards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittai of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Dace: /0-10 -ILI By: SI I Ace Fire and Security Systems, a UL listed fire and secure y a arm ins a a ion n company, submits the following description of work that will be done at the above listed location. Scope of Work REPLACE EXISTING S.T.0 FIRE ALARM DIALER WITH NEW A.E.S. RADIO COMMUNICATOR. E►,s,,•-� sr„ole-c dot. a.swt A s. . el' 40,414 cl`thr oh 41,. Lc,,1.i f UKWILA FIRE DEPARTMENT ?lease call 206-575-4407 and live this Fire Permit No. 'and exact address fbr shut- down hut:.sown or restoration approval. Scott Anderson sanderson@alarmcenterinc.com NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing rity Sys.ems Lo.._ 4,IL 985,,-323.. ;. ;3E•30'74-3-4244. 8 • Prone: 1-300-354-1555 r= V i- f 4 tY it a 1 7 CEILING/DECK \ /V \ A / MAX 30'-0" (360") CEILING MOUNTED HORN/STROBE SEE NOTE 2 SEE NOTE 4 6' 8" (80") SEE NOTE 5 51-0" (60") TYP MAX 4'-0" (48") MIN 3' 6" (42") CEILING MOUNTED HEAT/SMOKE SEE NOTE 1 WALL MOUNTED HORN/STROBE NI FAA SEE NOTE 6 1-114E 1160. PULL STATION SUSPENDED CEILING CEILING MOUNTED HEAT/SMOKE SEE NOTE 1 CEILING MOUNTED HORN/STROBE SEE NOTE 3 SEE NOTE 5 e FACU 0 FAPS MAX 6'-0" (72") & ' MIN 5' 6" (66") TYP FINISHED FLOOR NOTES I LOCATE CEILING MOUNTED HEAT/SMOKE DETECTORS ON THE BOTTOM OF THE DECK/SUSPENDED CEILING (NOT ON BOTTOM OF STRUCTURAL MEMBERS) AND AS INDICATED IN NEPA 72 2 LOCATE CEILING MOUNTED NOTIFICATION DEVICES ON BOTTOM OF BEAMS OR JOISTS WITH CLEAR LINE OF SITE IN ALL DIRECTIONS NO GREATER THAN THIRTY (30) FEET ABOVE THE FINISHED FLOOR AND AS INDICATED IN NFPA 72 3 LOCATE CEILING MOUNTED NOTIFICATION DEVICES FLUSH WITH THE SUSPENDED CEILING ALIGNED WITH LIGHTING SPRINKLERS AND OTHER ARCHITECTURAL FIXTURES WITH CLEAR LINE OF SITE IN ALL DIRECTIONS NO GREATER THAN THIRTY (30) FEET A F F AND A5 INDICATED IN NFPA 72 4 LOCATE WALL MOUNTED NOTIFICATION DEVICES AT 80" A F F TO BOTTOM OF BACK BOX 5 COORDINATE EXACT MOUNTING HEIGHT OF CONTROL PANELS ANNUNCIATORS AND POWER SUPPLIES WITH THE GENERAL CONTRACTOR ELECTRICAL CONTRACTOR AND AHJ PRIOR TO INSTALLATION 6 MEASURED TO THE OPERABLE PART OF THE PULL STATION TYPICAL DEVICE MOUNTING hEIGhT N T 5 f r 4 5 ar 1 t VICINITY MAP _Steamier Blvd - - Target Southcenter Plaza Suander B% d _ c t Y 4 __ lc? Mary s Logistlrs^ _ and Operations - SOUTHCENTER 480 Andover Park E Tukwila WA 98188 N C Machinery a 4 4 rk- Map date 62016 rocs, w i Jonathan Olson NICET #40743 Fire Alarm Systems Level 111 SYMBOL LEGEND WIRE FIRE ALARM POWER SUPPLY - PSN -64 1 FAPS SLC COI CEILING MOUNTED HORN/STROBE - 55 PC2R 5R 10 44 CEILING MOUNTED STROBE - 55 PC2R SR 13 MANUAL PULL STATION -POTTER APS 3 F END OF LINE RESISTOR E xxcd CANDELA RATING OF STROBE LIGHT (E) EXISTING DEVICE WIRE LEGEND WIRE DESCRIPTION TYPE A SLC 18 GAUGE 2 CONDUCTOR -FPLR C NAC CIRCUIT 14 GAUGE 2 CONDUCTOR - FPLR D NAC CIRCUIT # = CIRCUIT NUMBER 2 = OUT $ BACK CIRCUIT DOUBLE NUMBER OF CONDUCTORS FLAG NOTES NOT IN SCOPE OF WORK -THE OFFICE AREA HAS ALREADY BEEN DESIGNED AND PERMITTED BUILDING DATA ADDRESS PARCEL # AREA TYPE OF CONST OCCUPANCY 480 ANDOVER PARK EAST TU KWI LA WA 98188 2623049093 32 064 FT2 MASONRY F MONITORING SERVICE PROVIDED BY 44 ALARM CENTER INC PO BOX 3407 LACEY WA 98509-3407 PHONE (800) 238-9126 FAX (360 438-4244 ACCEPTED ❑ , Without Comments As Noted h Rei z - - ❑ Per The Attached Letter These plans have tee,. reviewed by The Tukwila Fre Prevention Bore 1 i `cf n ormance with current City sttardards Acce - #; s ,bjeCf- to errors and om ss'ons which c --=-atforize violations of adopted -andards and o c.---,----5 The respons'odicy for the adequacy of des= - ally with the designer - ud'tons, deletion - ---ti+sons to these draw ngs after r'+ls sate will ys c - _-er<71,-,' and will require a resubmittal of i y ` --3 v -,;s rc.r subsequent approval Final acceptance is suole t to tlelo test and inspection by The Tukwila Fire Prevenhor Bu eau Date TUKWILA FIRE DEPARTMENT Plum ca'i 206-575-4407 and gine this Fire Permit No. and exact addrers for shut - ( hut( )Wn or r S ' n approval PAID OCT 122016 TUKWILA FIRE tPL_GY,sciu tea, sq L{o Clz-' 116135' PO BOX 3363 CO o) 0 COw ..J 0 1) 0 0 2 0 z 0 10y 100 10 1r ag 00 cots v 0 a to a) 0 m o 0 0 re c 0 O. H 0 0 1 0 cc 0 0 10/03/2016 2 E 0 0 0 c 0 0 0 E co 1065F-40306 480 ANDOVER WAREHOUSE Tt z 5 u_i a 10/03/2016 AutoCAD LT 2009 m >, co z o_ (13 CO 1-00 a.-0�ta 0O > 1 cn OW I Liu Ne 00 It Et co a� ag CC a LLICs� zz� zaa� 0 co co Project Name Sheet Number M . 1 1of1 ( r OPEN/VULCANIZER ROOM ac=C0.-95 /77 STOKES FINIShIED GOODS ®95cd PALLET RACKING 95cd §30cd QC BLANKET $ EQUIPMENT PRODUCTION (-)75cd PRODUCTION OFFICE I1 11 e 75cd 95cd ®75cd DG ac=095cd SERVICE AND REPAIR 03Ocd FREEZER COOLER i3Ocd LAYUP$ DIRTY ROOM 95cd 015cd Airr4 '4, 1-11PPING AND RECIEVING 95cd }EASTMAN PKE-FRFG CUT ROOM • 75cd FREEZER 135cd 015cd DRY CUT ROOM PALLE RACKS A/ r /c 11 11 1'1 - I 171 yc 1,8. CC7,WO = 73 • f it " -it 0A) C,D RS& 95cd §95cd -C,D Fir (E) i 1 FACU 1 FAPS I r fl 0 / n fiFiL CUSTOM ASSEMBLY 1 D2 (-)30cd m X Pi r 1• 1 WAREHOUSE MK E ALARM PLAN 0' 4' OlimP9== SCALE: 1/5" = ' - 0" CONTRACTOR'S LIC. NO.-ALARMCI055CW 7 C 0 a. ru cc 10/03/2016 2 -1 0 0 0 0 E fa a as 1065F-40306 480 ANDOVER WAREHOUSE TI z 5 <I LL 0 0 0 AutoCAD LT 2009 E E co E 121.6.441121 CI)CI) Ow ui U.I w < < a. SI wg < LLI > > Z 0 0 .4e o Ci cn Z Z Z < 0 co co I— z0 0 Sheet Number FA.1 1 of 1 Cr) w 0 c -D w Cr) Two story office Not in scope of work QO EAST SYSTEM RISER r. FIRE HYDRANT Fei CC U WEST SYSTEM RISER WATER MOTOR GONG C FDC • Water Motor Gon 1 91 Grinnell 8" Model A Alarm Valve Grinnell Model A-2 Check Valve FDC WEST EAST O MT 11'-5" BOD Water Flow Indicator Alarm Valve fl OS&Y Control Valve Check Valve +---I- 8" Flex Coupling 00 3 Section View 1/2"=1'-0" Colncrete Wall Colncrete Slab I+I New kaki Main • Column Beyond FDC Plan View 1/2"=1'-0" Riser Detail Branchline 4x16 Purlins 8'-0" OC 2x6 Sub -Purlins 2'-O' OC Upright Sprinkler on 1 x 2" nipple with 1 x 3 ' RC I`i Column Beyond Full height wall 286 Degree Sprinkler in Skylight Maine Colncrete Wall CCEPTPD Without Comments As Noted in Red Per The Attached Letter plans have been reviewed by The Tukwila Fire - tion Bureau for conformance with current City ,3rds. Acceptance- is subject to errors and 3 -.-s--Ions which do not authorize violations of adopted s_' dards and ordinances. The responsibility for the a;-,-uacy of design rests totally with the designer. e tions, deletions or revisions to these drawings after date will void this acceptance and will require a -ubmittal of revised drawings for subsequent approval. • Final acceptance is subject to field test and Inspection by —♦- Ply Erie Tukwila Fire Prevention Bure u. Date: /*" �— 1 S By: l Building Section 1/8" = 1'-0" General Notes 1. Existing Fire Sprinkler System designed as Ordinary Hazard Pipe Schedule. 2. Existing Sprinklers are 1/2" Orifice, 1/2" NPT, 165 Degrees, Brass, Standard Response Uprights on 1" Sprig Ups with 1 x 1/2" RC. 3. Existing structure is Panel Construction with 4 x 16 purlins at 8'-0" O.C. framed into Glu -Lam Beams, with 2x6 sub -purlins at 24" O.C. 4. New insulation is being added to a depth of 12". 5. Cosco Fire Protection's Scope of work is to lower and replace existing uprights with new uprights on 1 x 2" nipple with 1 x 1/2" RC from the existing 1" branch -line outlets. 6. New sprinklers are 1/2" orifice, 1/2" NPT, 155 Degrees, Brass, Standard Response Uprights with a Maximum deflector distance of 6" below bottom of purlins. 7. Sprinklers in Unit Heater Zones to be 200 and 286 Degrees as required by NFPA 13. 8. Sprinklers in skylight to be 286 Degrees as required by NFPA 13. 9. No other modifications or additions to the existing system are in the scope of this work. 10. Provide 12 new sprinklers and head wrench in the existing spare head cabinets. 11. Replacement of sprinkler heads for new insulation to be in accordance with NFPA 13 and the City of Tukwila Fire Department and Building Department. 7 IJMILA ('iP.E Lam. RT E 1 i CZil 204-5754107 and -itis this Fire Permit No. and exact sckt s 1�r ut- down cr res rit' on appro 3. FIRE SPRINKLER EXISTING PIPING PLAN O 0 A\CVH PAS <E. fr 0,4 PAD ['EC 7 2014 2-93t7 WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Al Smith 4951-0192-C Level 3 Cosco Fire Protection, Inc. COSCOFP110NM GLP Signature Expires 12/31/14 Z 0 in re m N ,- SHEET NO. FP -1 0 TOTAL SPRINKLERS = 356 THIS SHEET 0 O 08 N O N O O ISH O 0 • a 0 0 0 0 0 0 0 0 0 O O 0 0 co cn (O (f•N O (u) •o N O F) N O D N O N N O F) N O -N N"9 O O 0 0 0 0 0 O 0 O 2 8 8 8 8 H NZ SC SL > > > N N 1 o CO O CO N O CO H0000 O O O Viking SR Upright O O O O O 00 0 0 0 0 0 0 DI \ / * \ / \ 0 0 0 O 0 0 0 0 0 • �� UNIT HEATER O O O O O O O O 0 O O O 0 O O 0 0 O O O O O O 0 0 O O O O O 0 0 O 0 � 00 O O O O O O O O O O n O O 0 9 O © 0 0 ❑ 0 0 0 0 0* 0 0 0 0 0 0 0 0 O UNIT HEATER o 0 • •cD • ° LOW WALL o • �; goo o ° o O O O O O 0 0 0 0 • O o UNIT HEATER 0 •0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 • O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 • o 0 O O O O O O O O O O O O O O • O 0 O O O o O O O0 O O O O O O o O O o •0 O 0 • O 0 0-- --• O O O O O O O O O O O O O O O • O 0 O O O O O O f O O O O O O O O O OO • O 0 O O O O O O O O O O O O O o 00 o P :" - I� I* o \\0— 0 0 0 0 0 0 0 ...4 0 0 0 0 0 0 0 • UNIT H=ATER° ° • O O 0 0 0 • ° o Two story office Not in scope of work QO EAST SYSTEM RISER r. FIRE HYDRANT Fei CC U WEST SYSTEM RISER WATER MOTOR GONG C FDC • Water Motor Gon 1 91 Grinnell 8" Model A Alarm Valve Grinnell Model A-2 Check Valve FDC WEST EAST O MT 11'-5" BOD Water Flow Indicator Alarm Valve fl OS&Y Control Valve Check Valve +---I- 8" Flex Coupling 00 3 Section View 1/2"=1'-0" Colncrete Wall Colncrete Slab I+I New kaki Main • Column Beyond FDC Plan View 1/2"=1'-0" Riser Detail Branchline 4x16 Purlins 8'-0" OC 2x6 Sub -Purlins 2'-O' OC Upright Sprinkler on 1 x 2" nipple with 1 x 3 ' RC I`i Column Beyond Full height wall 286 Degree Sprinkler in Skylight Maine Colncrete Wall CCEPTPD Without Comments As Noted in Red Per The Attached Letter plans have been reviewed by The Tukwila Fire - tion Bureau for conformance with current City ,3rds. Acceptance- is subject to errors and 3 -.-s--Ions which do not authorize violations of adopted s_' dards and ordinances. The responsibility for the a;-,-uacy of design rests totally with the designer. e tions, deletions or revisions to these drawings after date will void this acceptance and will require a -ubmittal of revised drawings for subsequent approval. • Final acceptance is subject to field test and Inspection by —♦- Ply Erie Tukwila Fire Prevention Bure u. Date: /*" �— 1 S By: l Building Section 1/8" = 1'-0" General Notes 1. Existing Fire Sprinkler System designed as Ordinary Hazard Pipe Schedule. 2. Existing Sprinklers are 1/2" Orifice, 1/2" NPT, 165 Degrees, Brass, Standard Response Uprights on 1" Sprig Ups with 1 x 1/2" RC. 3. Existing structure is Panel Construction with 4 x 16 purlins at 8'-0" O.C. framed into Glu -Lam Beams, with 2x6 sub -purlins at 24" O.C. 4. New insulation is being added to a depth of 12". 5. Cosco Fire Protection's Scope of work is to lower and replace existing uprights with new uprights on 1 x 2" nipple with 1 x 1/2" RC from the existing 1" branch -line outlets. 6. New sprinklers are 1/2" orifice, 1/2" NPT, 155 Degrees, Brass, Standard Response Uprights with a Maximum deflector distance of 6" below bottom of purlins. 7. Sprinklers in Unit Heater Zones to be 200 and 286 Degrees as required by NFPA 13. 8. Sprinklers in skylight to be 286 Degrees as required by NFPA 13. 9. No other modifications or additions to the existing system are in the scope of this work. 10. Provide 12 new sprinklers and head wrench in the existing spare head cabinets. 11. Replacement of sprinkler heads for new insulation to be in accordance with NFPA 13 and the City of Tukwila Fire Department and Building Department. 7 IJMILA ('iP.E Lam. RT E 1 i CZil 204-5754107 and -itis this Fire Permit No. and exact sckt s 1�r ut- down cr res rit' on appro 3. FIRE SPRINKLER EXISTING PIPING PLAN O 0 A\CVH PAS <E. fr 0,4 PAD ['EC 7 2014 2-93t7 WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Al Smith 4951-0192-C Level 3 Cosco Fire Protection, Inc. COSCOFP110NM GLP Signature Expires 12/31/14 Z 0 in re m N ,- SHEET NO. FP -1 0 TOTAL SPRINKLERS = 356 THIS SHEET d uJ W H Q in 08 N 8 N N ISH C LDESCRIPTION • a a 0 c 0 z WZ O 2 O 2 QUAN. 328 N ,- SHEET NO. FP -1 0 TOTAL SPRINKLERS = 356 THIS SHEET d uJ 2 08 N 8 N N ISH C 0 • a a 0 c 0 0 WZ O 2 O 2 =7_ ao co cn o0 U yo •o ..o -o iui Lei ui lri APPROVALS BY: CITY OF TUKWILA W o 2 8 8 8 8 H NZ SC SL > > > > 1 o CO O CO N O CO H0000 SPRINKLER HEAD LEGEND : Viking SR Upright Viking SR Upright on Sprig in Skylights Viking SR Upright Viking SR Upright 1101601• ••ii a • • s O 000 0003 0000 O 000 • • • • i • • • U IJ 1- 0 re a IiJ W z 0 i~ z a License No: U 0 0 COSCOFP1 1ONM 0 0 0 0 0 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE t) a) 1 � 0 N 0 E O o UW O 4-)°' L' o a)o_ CONTRACT WITH: DRAWING TITLE Fire Protection Plan DATE: 12/15/14 SCALE : 1/8" = 1'-0" DRAWN BY : Jared Brandon JOB NO. 25SS8362 SHEET NO. FP -1 0 GLU-LAM OR BEAM MODEL #GST 20 ALL THREAD ROD HANGER RING SAMMY SUPERSCREW HANGER TYPE S NTS 28'-0" watumatmllM GLU-LAM OR BEAM MODEL #SWG 20 ALL THREAD ROD HANGER RING SAMMY SIDEWINDER HANGER TYPE SW COM NTS 22`-G" +1 MECH. TEE INTO (E) 2" BRANCH LINE 1" SCH 40 DROP 1 x SHO NIPPLE 48" FLEXHEAD �-- CEILING BRACKET 1/2" SSP FLEX DROP NTS 22'-0" PS1100 STRUT CLAMP 1-5/8" STRUT TECH SCREW WASHER RIGID FOAM INSULATION SHEET METAL STRUT & STRUT CLAMP HANGER TYPE X 22'-0 NTS .1'-O" 2„'_0„ ThOuaS Wltr � -• m -'-�:- As Not Per The Att,Ci:l,.tetter These plans have heen reviewed ;,v The Tukwila Fire "rpvention Burea;i frir confOrMar)r j current City ..;-raraards. Acceotance is siubiec'- t rors and •-:cn -ai=r- which moi, 1;cri t ori7-_ ^:'�itiOils of adopted - to^oar ds and The , esI .i,siniiity for the ; guacy Of totaiik, with che designer, ,6ditions, cielerif-". •.- -?,,isiors to these drawings after his CaiiH- �;1 '_Y- i .-- =3%i epca : �ri4� ix31F.1 require e a r esubsrlitta. r ._ - �r�:\l�r'- I"; •: pprovai. i ' Final ac :. u4e 4 to rleid test ano inspection by 'The. Tukwila Feyentior Bureau. Date: c15-�� ! By: N Fill ILA FIRE NPARTMEN' T C.3,L -5754407 and Perririlt 51 shut- � 4pi ova. r 1 • 1 . 2'4"-0" 281-0" 1 OVEN / VULCANIZER 9 O REMOTE AREA #1 THIS AREA HAS BEEN HYDRAULICALLY CALCULATED TO DELIVER A DENSITY OF: .15 GPM/SF OVER 1585 SQ FT SYSTEM DEMAND @ BOR: 572.6 GPM @ 93.6 PSI 1 1 Li O Cv O CV CV 0 O O O O O cv O O O O (D r STORtS FINISHED GOOF 40' x 581-6" r O s. Ca O O _O. r O r BLANKET & EQUIPMENT PRODUCTION 173'-6" x48' BONDER/BLANKET SUPER MARKET 15' 6 1 4-6 2 1-0 15-0 -.A L ih -1 4 - } ! t i v 2 7-5 "`' W,d.12'-0" ACT PRODUCTION iON OFFL E ^ 4 *13'-OFFS CiIs *13'-0"FFc co 12'-O ACT O r.__ D6 ' 4 O d _ Q- ...+.. v 0 0 RESALE CONSUMABLES 30'x20' tv O C�l 0 CV O O O 0 O O r t • C7 1 r0act N CS 1Y *133'-0"Foi \JIP 34 I- y1��1y N � \ c1a 2 0/ 8-7 12-8 4,4 EASTMAN & PF.E-PREG CUT ROOM i% ti 29 4(_ ;. (�) c24 DN 1 x (7-0) W/ 1" AUX. DRAIN ( ��oj (OFFSET FOR CLARITY) 13'-0" SERVICE & REPAIR O j �-u o IM jit C�4 12-8 v f o u O r 1 A LAYUP & DIRTY ROOM 6 O X 12" -Cr GWB 9 / T COMPRESSOR t VACUUM PUMFri, 1-0 2- 0 10 1: 1'/: 0-6 -J ACT ROOM 1'/ C,v CV r ;Th U r O O 0 O O g3-101: �'t) 6-6 o 11/4 + 114 5-6 1'/+ . 11/4 + 1'/4 3-101/2 ' 6-6 5-6 12'-6"FI#q 4 + + 11+ 3-10% 1'/4 0/+ 1% 6-6 5-6 CV /+1'/4 12-0 C". +1% / 12-03-6 1 -10 0-6 8� e i to 6 ! 6 ne 1'/4 + 114 _J / G 8-6 1141'/ 12-0 /+ c0 r� 1% 12-0 1% 12-0I 14 -6 u ti 0 EXISTING FIRE SPRINKLERS TO REMAIN 2 0 0 4,1 1 HYDRAULIC DESIGN INFO. THIS SYSTEM IS NOT T1HYI:RSAYLEM ISY DESIGNED HYDRAULICALLY DESIGNED STATIC: 140 RESIDUAL: 130 GPM FLOWING: 2000 - SYSTEM DESIGN - REMOTE AREA: AREA 1 DENSITY: .15 GPM / SQ FT MAX AREA/HEAD 130 SQ FT K -FACTOR 5.6K 0 tTh FIRE SPRINKLER PLAN - LEVEL 1 71 SCOPE OF WORK: ADD AND RELOCATE UPRIGHT AND PENDENT SPRINKLERS AS REQUIRED FOR NEW WALLS AND CEILINGS. PROVIDE SPRINKLER PROTECTION FOR NEW COOLER. PROVIDE SPRINKLER PROTECTION NEW OVENS. GENERAL NOTES: 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 2. PIPING DIMENSIONS ARE CUT LENGTH EXCEPT RISER DIMENSIONS AND MAINS, SHOWN THUSLY (1-6), WHICH ARE END TO END. 3. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13 (2013). 4. PIPING SHALL BE IN ACCORDANCE WITH NFPA #13 (2013). 5. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED, SHALL BE IN ACCORDANCE WITH NFPA #13 (2013). 6. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 7. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 8. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. DESIGN NOTES: 1. DESIGN AND SPRINKLER SPACING TO BE PER NFPA #13 ORDINARY HAZARD GROUP 1. 2. PLAN SUBMITTAL TO AND APPROVAL BY THE CITY OF TUKWILA. 3. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY FSI. 4. TESTING PER NFPA #13 AND THE CITY OF TUKWILA. FIELD NOTES: 1. ALL NEW PIPE TO BE BLACK, SCHEDULE 40 WITH BLACK, DUCTILE IRON THREADED FITTINGS. 2. SPRINKLERS IN ACT TYPE CEILINGS TO BE INSTALLED ON 1" X 1/2" X 48" FLEXHEADS. 3. SPRINKLERS ARE NOT REQUIRED TO BE LOCATED IN THE CENTER OF THE CEILING TILES. 4. ARMOVERS LONGER THAN 1-0" SHALL HAVE A HANGER. 5. TYPICAL HANGER TO BE A SAMMY SIDEWINDER (UNLESS NOTED OTHERWISE). 6. MAX SQ FT PER SPRINKLER = 130 SQ FT. WALL LEGEND: = EXISTING WALL CONSTRUCTION - NEW WALL CONSTRUCTION - NEW FULL HEIGHT WALL CONSTRUCTION SPRINKLER PIPE LEGEND: - = EXISTING SPRINKLER PIPE = NEW SPRINKLER PIPE = NEW FLEXIBLE SPRINKLER DROP SPRINKLER LEGEND: 0 = EXISTING UPRIGHT SPRINKLER = ADD NEW PENDENT SPRINKLER = ADD NEW DRY PENDENT SPRINKLER = ADD NEW EC PENDENT SPRINKLER SITE KEY PLAN SCALE: NTS VICINITY MAP SCALE: NTS PAID AUG -4 2016 TUKWILA FIRE 111•1191111111• MMMMM Wel M11•11111111111.11 WASHINGTON STATE 1 CERTIFICATE OF COMPETENCY Dral:drit:TiSiee:Tkil" SPRINKLES SYSTEMS 1470-0793-C Level 3 Fire Sprinklers Incorporated FIRESI* 88 2 .„ naluee DESCRIPTION 03 cc DRAWING SYMBOLS - WELDED PIPE TAG CC NP - (72 LL1 LU ET_ ca 0 W CI 0 0 re 00 x _ILLI 0 u. 0 0 El- rc W 1 - cc 0 cn ,s$ 0 HANGER LEGEND SAMMY SUPER SCREW (GST20) SAMMY SIDEWINDER (SWG20) STRUT AND STRUT CLAMP SPRINKLER LEGEND LO >- a. 0 0 cc cc ee cc LLI CO CO CO Ur LO LO 0 CNA LO SPRINKLER TYPE QR STANDARD SPRAY PENDENT QR STANDARD SPRAY DRY PENDENT CES 1135 I SR EXTENDED COVERAGE ORD. HAZ. PENDENT CO CO CO TOTAL THIS SHEET CO X CI - co 0) CO :103 rOdd WA CL# FIRESI*988RJ CZ CZ CIO 0 0 CL ad CO as co co ALI 0 LI-