Loading...
HomeMy WebLinkAboutPP - 1150 ANDOVER PARK EAST - MULTIPLE TENANTS - PERMITS AND PLANS1150 ANDOVER PARK EAST ASSOCIATED PERMITS 18-F-201 EL18-0879 PW15-0097 15-S-112 44ittlair444 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 2623049089 Site Address: 1150 Andover Park East Tukwila, WA 98188 Suite Number: Floor: Tenant Name: Mondo and Sons, Inc. New Tenant? ❑ -Yes 0 -No Property Owner's Name: Mondo and Sons, Inc. Mailing Address:1150 Andover Park East Tukwila, WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Manny Ornelas Day Telephone: 206-436-5301 Company Name: Washington Alarm Mailing Address: 2030 Airport Way S City State Zip E-mail Address: permits@washingtonalarm.com Fax Number: 20e-322-7214 Contractor's City of Tukwila Business License number: BUS -0992857 Total number of new/relocated devices or sprinkler heads: New 29 Valuation of Project (contractor's bid price): $ 9,100 Scope of Work (please provide detailed information): Replacing existing 8112 panel with new Silent Knight 5808 Installing AES Radio Communicator and upgrading notification. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ' ' OR AU GENT: Signature: PAI® CCT 112;11 1 Date: 10-11-2018 MannyOrnelas TUKWILA FIRRm06-436-5301 Print Name: Day Telephone: Plan Permit App.doc 8/22/14 TFD FP Form 8 / INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /8 -F-moo/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Type 070 Vi gewl, of Ins ion: Address:Contact Suite #: //SD erson: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: iN4e4d1 frfe") //Iwo , riar-we O�f4 ue_ ,c..e00.-24 ),6 arc lood•e--.,.a,..- P� Needs Shift Inspection: %eQ Sprinklers: yie4r Fire Alarm: 1/$4 Hood & Duct: Monitor: Own Pre -Fire: Permits: (�=& ) ' —32-$ ,Occupancy Type: 0•o Inspector: �:641i n#C3 Date: /lt9h 9 Hrs.: /, 6 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 CORRECTION NOTICE/REINSPECTIUN FEE Inspector: jl4 eVf' Permit number: TUKWILA FIRE MARSHAL'S OFFICE Office: 206-575-4407 Fax: 206-575-4439 Email: Fire Marshatukwilawa.gov Business Name:Type -2i'SGt-(15 of Inspection: CSF/Dem Ile -pail Location Address: of n �- Date : /./C6 Contact Person : k k "cw) I2jpN G-1 CnG Phone No. : 206 s is Lt Lic rJ ACTION REQUIRED : (1 -4/t --z-7`2 6 i,i 5 %3 {`l✓ SP r.i kte--rL S Sr-&' _ pew- ,acc--72___ ( 687.)# 6 D-4---1) C r,74- I( K (t3 -- we J 4— Ulr.e, 1 d /4 ,��yl / p'/q-A ,,Q Er .\jvi d ,:t:1 A- . 1 (iscj, cv\N' " - CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY : 13 / FAILURE T 1 COM ' LY MAY RESU IN THE ISSUANCE OF A C ' INAL CITATION/TICKET. Signature: Billin ailing Address : Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Reins') Fee2.doc Revised 6117/14 T.F.D. Form F.P. 100 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILAE DEPARTMENT 206-575-4407 Proje , 76AT.I'‘. \ S likke,tief-s Type of Ins ection: se ioN Address: Suite #: /6Q Are - Monitor: Contact erson: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COI tMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: r M `4, C Liz.c46-7 — KA4s4lel f gep.[A5 GQt.., – CLOYa.r © IL_ ( .— oa of — 4; Ng — –PP6S Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector• �i �f3 Date: 9/,i /, Hrs.: /, 6 v- $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billin4 Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 TUKWILA FIRE MARSHAL'S OFFICE Phone: 206-575-4407 • Email: FireMarshal@tukwilawa.gov OistilW414 CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date /-",02— Permit # Property Address 1/67 4jj W /e ?# t iL. Suite # City TUKWILA Zip Code 9/f/ff Name of Facility /0/1/9, S-CW5 Occupied as //pal rykr Ail/U Owner or Representative / Phone # Installing Company With/ s'%kAti 4 (item . Installin Contractor's Address aQ 3o 4.790e toy, so . City �� 1 e Phone # SAF ` _Zer Installer's Name (PRINT)//o1 ��Ffi License and/or Certificate 4i!..5LW L GSC L. General Contractor CL/Y- d'71 Electrical Contractor u/,Acf'02 (3 FACP Equipment Manufacturer /-erit `/ Model # /11101 This system has beenin talled, pre-t�s�a d operates in accordance with the standards listed below and was inspected by 6{)/// f/ On (date) / 02 / /f and includes the devices listed on back. Circle all that apply: YNFPA 72, Chapter 1 2 4 5 6 7 and/or IFC SEC 907 I /NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions j/ Manufacturer's Instructions Other (specify) Tukwila City Ordinance Numbers 2050, 2051 UL Central Statin Monit r SIGNED a System Firmware: Installed version Initial program Installation Revisions and Reasons U ' Checksum System is monitored by (, J », / Alt"S Att-e--. Date Date Date Programmed by (/L' i` I /bSf EQUIPMENT INSTALLED AND TESTED: Control Panel j of / Manual Station of Smoke Detectors J of L Heat Detectors of Duct Detectors of AN Devices II 4 of I �f Audio Devices Visual Devices 5 of .� Auto Door Release of Trouble Indictors of Batteries Make/Model Make/Model Make/Model Make/Model Make/Model / vilve// 40(.4 Make/Model S 1 S Pz tvl SEi t f cL Make/Model Make/Model Make/Model Make/Model s cis k m 55uv . Readings Battery Full Load Charge Generator HVAC Controls Fire Alarm Dialer Monitored by Annunciator of Make/Model of Make/Model of Make/Model of Make/Model ❑ Sprinkler System. (Fire Alarm connections only) Make/Model / .SG(P� 5a)/1:71 -fie/". — 7.3#€ / Make/Model , 44/' — Make/Model i✓,1- U — ihof/ Make/Model Water Flow Sw. / of Valve Tamper Sw. f of PIV ( of Elec. Alarm Bell of Automatic time Delay of Water Flow Alarm ?(:) seconds. None Installed Do you meet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes J No Test of alarm System on emerge cy power, satisfactory? Yes kNo Test Witnessed by j// / .T& Title Seth e14/ Date / —021- /' Comments: Fire Alarm Certificate.doc Revised: 6/17/14 TFD FP Form #110 0 two IFire & Security Scope Of Work Project Name: Pacific Powertech 1120 Andover Park E. Tukwila, WA 98188 Fire Alarm System Monitoring By: ADT Security Services 11824 North Creek Parkway N., Suite 105 Bothell, WA 98011 ADT Representative: JEFF MCLAUGHLIN Telephone: 425-402-3351 Quantity Model Description 1 1 1 1 2 2 1 4 NOTE: 472462A 471210 429CTAD (Connection Only) (Connection Only) (Connection Only) (Connection Only) (Connection Only) Focus 200 Fire Alarm Panel Annunciator Smoke Detector Duct Detector Water flow Switch Tamper Switch Hi/Lo Pressure Switch Horns 1. Install new Focus 200 Fire Alarm Panel. 2. Install new annunciator at FACP. 3. Install smoke detector above FACP 4. Connect all existing devices to new FACP. 5. Panel is programmed for monitoring. two IFire & Security Battery Calculation Worksheet (all currents stated In mA) 4/28/2009 PROJECT: PACIFIC POWERTECH Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Focus 200 Fire Alarm panel 1 300 440 300 440 Focus 200 Operating Keypad 1 32 65 32 65 0 0 756 Total System Standby NH 0 0 33 0 0.06 Min. NH Battery 0 0 0 0 2.42 ' 10.47 I Required NH Battery 0 0 Total System Current 0 0 332 505 Smoke Detectors / Auxiliary Devices 429CTAD SMOKE DETECTOR 1 1 3 1 3 5 Total System Standby mA N/A 366 0 0 756 Total System Standby NH N/A 7.99 33 0 0.06 Min. NH Battery N/A 8.05 0 0 2.42 ' 10.47 I Required NH Battery N/A 0 0 0 N/A 0 0 0 N/A 0 0 Device Totals 1 34 3 Notification Appliances (list all) HORNS (EXISTING) 4 N/A 62 N/A 248 5 Total System Standby mA N/A 366 N/A 0 756 Total System Standby NH N/A 7.99 N/A 0 0.06 Min. NH Battery N/A 8.05 N/A 0 2.42 ' 10.47 I Required NH Battery N/A N/A 0 0 N/A N/A 0 0 N/A N/A 0 Notification Appliance Totals 4 N/A 248 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 366 Total System Alarm mA 756 Total System Standby NH 7.99 Total System Alarm NH 0.06 Min. NH Battery 8.05 ADD 30% FOR BATTERY DEPLETION 2.42 ' 10.47 I Required NH Battery !NH BATTERY PROVIDED FOR SYSTEM ' 12 DO NOT EXCEED TOTAL CURRENT DRAW OF 3000mA SITE LOCATION Site Address: CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Tenant Name: ?el -5c t. `s i'tt••-k I1 SO L(_C 56l`t°►`I Property Owner's Name: Mailing Address: 425 12rt-,str /�Jc S King Co. Assessor's Tax No.: 223 049(.471 Suite Number: NA Floor: 1 New Tenant? ❑ - Yes E( - No CONTACT PERSON -if there are questions about the submittal. Name: McAlltw 12411°V) Company Name: i1 SPA •- St -e- . !! Mailing Address: j'$Z�F 4.5 -' ,Sf- £ - �vi+C• /OZ E-mail Address: City w4 9'ii? State Zip Day Telephone:( Zs3) TV, - 001 '1 SJ fK,w wit Contractor's City of Tukwila Business License number: 11/4-1S — Total number of new/relocated devices or sprinkler heads: y' Valuation of Project (contractor's bid price): $ I't �qo City State Zip Fax Number( Z51) tt'hh—/j33 09141-43 Scope of Work (please provide detailed information): i4 € 1/r °ted(. s '. �" L°r' r• �/° / ca$1,r j z Lt{C. y.ra <.� PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: LCv 4?i FSL Date: 6/30A ! S Day Telephone: ( 253)V ZL — Ot,1`I Plan Permit App.doc 8/22/14 TFD FP Form 8 GLU-LAM OR BEAM MODEL #GST 20 ALL THREAD ROD HANGER RING SAMMY SUPERSCREW HANGER TYPE S NTS gar* 6-1&t, 4t1f71 '1,114° *z-450 Comments o As Notee o Per The �ach Leiter Thee plans have beer- rewc bv The Tukwila Fre ',•-••.:ve.ntion Bureau fcr conforrnar.,-e%-vit'A current Ciry .-randarcis. Acceptance is suoject to e-rfors and oi-hisSions which 00 not atiti-oriz.e -,-lolations of adoc.)iexi : S,.anciarcis ano ordinances_ The resoonsibfiity for !the adequacy of design resrs totalwith tt-e desigper. Additions, deletions or revisions r.o rhtse drawinf,r- a -:ter this date will vod this accet-)tawce. arid Ali require a resubmit -WI of revised drawirm.-: subsegticht approveL Final acceptance Is subject to field test ancl inspection by Tne Tukwila Fire Prevention Bureau. A Date: ?' C By: f TUKWILA FIRE CEVARINE'fr call 206-5754407 and lvt.k:-.is Fire Permit No. 1J - S lnd exact ss or shut - own cr re:.-toaton approvl. AREA OF WORK KEY PLAN SCALE: NTS REPLACE BACKFLOW PREVENTER (SEE SCOPE OF WORK) 2-' COOLER 1 #116—e 0-11% 1N:.\\ '2 2-2% w : I LLa I ! I 11112 FIRE SPRINKLER PLAN SCALE:1/4" = R , I SCOPE OF WORK: ADD AND RELOCATE SPRINKLERS AS REQUIRED FOR THE NEW COOLER. REPLACE EXISTING BACKFLOW PREVENTER IN VAULT WITH NEW STATE -APPROVED MODEL (BACKFLOW WORK TO BE SUBMITTED SEPARATELY TO CITY OF TUKWILA DEPARTMENT OF PUBLIC WORKS). GENERAL NOTES: 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 2. PIPING DIMENSIONS ARE CUT LENGTH EXCEPT RISER DIMENSIONS AND MAINS, SHOWN THUSLY (1-6), WHICH ARE END TO END. 3. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13 (2013). 4. PIPING SHALL BE IN ACCORDANCE WITH NFPA #13 (2013). 5. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED, SHALL BE IN ACCORDANCE WITH NFPA #13 (2013). 6. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 7. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 8. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. DESIGN NOTES: 1. DESIGN AND SPRINKLER SPACING TO BE PER NFPA #13 (ORDINARY HAZARD). 2. PLAN SUBMITTAL TO AND APPROVAL BY THE CITY OF TUKWILA. 3. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY FSI. 4. TESTING PER NFPA #13 AND THE CITY OF TUKWILA. FIELD NOTES: 1. ALL NEW PIPE TO BE BLACK, IMPORT SCHEDULE 40 WITH BLACK, DUCTILE IRON THREADED FITTINGS. 2. SPRINKLERS IN ACT TYPE CEILINGS TO BE INSTALLED ON 1" X1/2" X 48" FLEXHEADS. 3. SPRINKLERS ARE NOT REQUIRED TO BE LOCATED IN THE CENTER OF THE CEILING TILES. 4. ARMOVERS LONGER THAN 2-0" SHALL HAVE A HANGER. 5. TYPICAL HANGER TO BE A SAMMY MODEL GST -20 (UNLESS NOTED OTHERWISE). 6. MAX SQ FT PER SPRINKLER = 130 SQ FT. WALL LEGEND: = EXISTING WALL CONSTRUCTION - NEW WALL CONSTRUCTION SPRINKLER PIPE LEGEND: - = EXISTING SPRINKLER PIPE - NEW SPRINKLER PIPE "4446issii. = NEW FLEXIBLE SPRINKLER DROP SPRINKLER LEGEND: = EXISTING SPRINKLER = PLUG EXISTING SPRINKLER • = RELOCATE PENDENT SPRINKLER + = ADD DRY PENDENT SPRINKLER Err ; ..tEE Err: = - - --:= r•-• ' RFC ii71'..=• ailbarirt = C-1-^ •-• ' --141,et) = 4-173.0i4.67i I - • VICINITY MAP SCALE: NTS PAID JUN 3 0 '2015 rUKVVILA FIRE 5 ,7° V • WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS David Usiecki 1470-0793-C Level 3 Fire Sprinklers Incorporated FIRESr 88 • Si nettle DRAWING SYMBOLS 0 < I- UJD tiW ra: 0 W o --I z 7_1 i 0 Lli ZIT} ..r 2 oe D 0 Z w2 wi NI- NI- - 0 - (1)Z (1)Z w w WW (2_ _i ci_ -07. 05 ET_ . co LU z Z P0 :3 I- 1.7- IY Lij 0 < 2 w ti > D I- -,-.7 wl- Z-(..) 0 LU 0 0 0 a , -J & (4 06 "- . b 0 Lu 0 0 0 > 0 w rx > 0 ,,., 0 0 iiii %.:.) W Z 0- X D a 0- - D W ,-, _1 t.../ 2o LI_ U- 0 CL 0 Q- u_d, + f= 2 (-) W W LLI - cn guj 0 M V) [1-.1 co —_„.. Lu a 0 z 1 ›- HANGER LEGEND i---- .--,-; _ t_i_ ..+L ------ 0 — Li-. z..,-.) _ i :::) -_-.-_:: SAMMY SUPER SCREW (GST20) SAMIVIY SIDE W ---,-,-: -. ... , - ;;;-- --- --z_ - - - Ly7_. 0 SPRINKLER LEGEND ›- I- 0 0..1 CV CANOPY CHROME CHROME TOTAL THIS SHEET FINISH CHROME CHROME u j i_ 0 tx) 14-3 •,- 0 C3 C,.I 0 < w CC I- , (Ni ,_ •- 0 < LI_ co tri CO 6 SYMBOL • • MODEL C‘l CD > •cf- LC) > MFG VIKING 0 Z Y > SPRINKLER TYPE / SIN NUMBER SR STANDARD SPRAY PENDENT SR STANDARD SPRAY DRY PENDENT Petchl's Meats 1150 Andover Park E Tukwila, WA Rowley Refrigeration 3807 South Road Mukilteo, WA 98275 P.M. Jay Rowley (206) 730-3446 91I a r•-4 0 0_ CO C • UJ Z 0 (7) W 0 LC) EEL CV Csi C V CD -3 Li I- < 0 ID 03.> Z LI) < Cli _i < C3 GO CD --- = I- 0 (3 '-i = < Is -- CV CO 4t CO - I-1- 0 CL ILL ' 4t F- i W LU = CO N2-4 75 FREEZER 75 N2-6 75, 30N3-6 EOL _ EOL PRODUCTION ROOM N2-2 30 SBUS FROM FACP #14/4 AWG #16/2 TWP HALL SLC FROM FACP ELECTRICAL ROOM FROM FACP-1 S-01 AES FACP 7 FROM FACP- 1S SHIPPING OFFICE FROM #14/2 AWG FACP-3 LOADING DOCK sz' Tne D W th t Comments APer sNYS I Red P e r? e 'A ..--, c -. d Letter ;Lh N3-4 _. ,d •-•r c�' b , The T ''tt ll Fire clans hard h,�::. re�4 ��� ' �.�,' � -�. u., , f-i nnt.lon Burr; `moi conformance w th current City tiai s. Ac ,ranee is sLibject and ♦ ir. ,t:iornz �o!i t�. of adopted Yi�!i,.��i. do .~v. :�4 _'}'.� Vii.=_ �l.- _ .�. ,� i.:4: bS�, ti-�-. fieres and or d ner:;.lis The res;_' ,ne-;:oiiit'y for the L L.�.•�♦ i h the -deli' er. - = t_.-=.1���'ii ofii��.?'wi. i�`�.'`.:,�-4;<i,T 4`;;=Vii. 4 7.isj loos is et o ts#- r rf. VIS/OP-S to t cae ` ii'`w]ngs h's date 41`-19 vo:d t ris ,'':ic a re a resu'bi i t of revised ftc sub e- cent approy_; M-06 !WF 1/ M-05 VSW Y r ---I M-04� ( M-03 _ VS M-02 - 1 Fnal cc t.- :' :.e is sunyC� t ` s'id fest and Inspection j The i uk I Fiee i _ 1 e s 7.N.t.o % 6._.=i -eau. PIV CONFERENCE ROOM y SYMBOL DESCRIPTION N1-7 75 WP DEDICATED 1 CIRCUITS L—_1 bE l,1Actil rmui %( ra(/ I‘,5-1/4 11 1714kt.- 1.mitqtie Gkctoy ots 6444(e F4 b,14Ae—. SBUS #14/4 AWG TIJKWILA FIRE DEPARTMENT Pease ase call 206-575-4407 and c;ve t' Fire Permit No. yam.0 .} rid exact address for sh- t.::i'iNn or r"tet^,' : OOn eppr0' moi. S-01 M-01 #16/2 TWP FACP 1 WIRELESS FIRE ALARM COMMUNICATOR FACP-2 m PIV M-02 M-03 M-04 15 15 15 15 15 VS MM M-05 M-06 0 WP 75 EOL N1-1 N1-2 N1-3 N1-4 N1-5 N1-6 N1-7 #14/2 AWG WP0 WP V 0 WP 0 WP 75 WP 5 WP Y 75 N2-1 N2-2 N2-3 N2-4 N2-5 N2-6 #14/2 AWG WP 5 WP 15 WP 5 WP V 30 WP115 WP FACP 3 EOL EOL IP FACP-4 BATTERY I BATTERY NO CONDUIT IN BOTTOM OF CAN N3-1 N3-2 N3-3 N3-4 N3-5 N3-6 #14/2 AWG EOL MAN #14/2 AWG FIRE ALARM RISER DIAGRAM SCALE: FIRE ALARM SYMBOL LEGEND NOTE: ALL SYMBOLS MAY NOT 8E USED ON THIS PROJECT SYMBOL DESCRIPTION MOUNTING ACTIVATE AUDIBLE SUPERVISORY SIGNAL FIRE ALARM CONTROL PANEL WALL -TOP 0 66" FACP TRANSMIT SUPERVISORY SIGNAL FIRE SYSTEM ANNUNCIATOR WALL -TOP 0 66" FSA 0 SMOKE DETECTOR CEILING MANUAL PULL STATION WALL 0 48" P POST INDICATOR VALVE BY OTHERS PIV • ADDRESSABLE MONITOR MODULE FIELD VERIFY M VALVE SUPERVISORY SWITCH BY OTHERS VS WATER FLOW SWITCH BY OTHERS Eg (0) CEILING MOUNT STROBE FIELD VERIFY (Q) CEILING MOUNT HORN / STROBE FIELD VERIFY HORN / STROBE WALL 80"-96" X t STROBE WALL 80"-96" X ABBREVIATION DESCRIPTION 75#-CCANDELAN3 0 TANN E EXISTING G WITH GUARD P PENDANT MOUNT O of -DEVICE ADDRESS - O L1D001 OR D01 - DENOTES LOOP (D or M - ENOTES DETECTOR 0 MODULE ) R RESIDENTIAL (110V) S SOUNDER BASE WP WEATHER PROOFL EOL END OF LINE RESISTOR EOLR END OF LINE RELAY 1- 16 2 TWP AWG AMERICAN WIRE GAUGE TWP TWISTED PAIR WIRE TYPE ABBREVIATED CONDUCTOR COUNT TWSP TWISTED SHIELDED PAIR FPLP FIRE POWER LIMITED PLENUM WIRE SIZE OMITTED FPLR FIRE POWER LIMITED RISER OF CABLES (IF gNLY 1 CABLE NEEDED) NAC NOTIFICATION APPLIANCE CIRCUIT SLC SIGNALING LINE CIRCUIT OPERATIONS MATRIX l- 0 — , 0 C Q w FIRE ALARM INPUT EL ACTIVATE ALARM INDICATOR ACTIVATE AUDIBLE ALARM ACTIVATE SUPERVISORY INDICATOR ACTIVATE AUDIBLE SUPERVISORY SIGNAL ACTIVATE TROUBLE INDICATOR ACTIVATE AUDIBLE TROUBLE INDICATOR TRANSMIT ALARM SIGNAL TRANSMIT SUPERVISORY SIGNAL TRANSMIT TROUBLE SIGNAL ACTIVATE NOTIFICATION APPLIANCES SMOKE DETECTORS • 0 • • PULL STATIONS • • 0 0 WATERFLOW SWITCHES • • • • VALVE TAMPER SWITCHES • • • FIRE ALARM AC POWER FAIL • • • FIRE ALARM LOW BATTERY • • • OPEN CIRCUIT • • • GROUND FAULT • • • NAC SHORT CIRCUIT • • • LOSS OF AC TO BUILDING 0 • 0 PAID CCT 11 201 TUKWILA FIRE �e 3� Brad -B_ aws} Signature Date: 10/9/2018 Fire Protection Engineering Technology Alarm Systems Cert. No. 138751 Exp 5/1/2019 shop drawings seated by. 5794 W.4600 So. Hooper, UT 84315 Office: 801.985.0410 a CADInc. www.unicod.net Fi-re-Afarmt-Design &Dralkttng Service 00 0 N O O DESCRIPTION ISSUED FOR REVIEW & APPROVAL z 0 W re 0 1253 S JACKSON ST. SEATTLE, WA 206-328-3288 MONDO AND SONS 1150 ANDOVER PARK E LL DRAWN CRL UNICAD JOB #18623 CHECKED BRADY B. HAWS NICET III 138751 DATE 10/09/2018 REVISION 0 SCALE 1/8"=1'-0" FA -1 FACP Battery PROJECT NAME: Required Standby Time: Required Alarm Time: Calculation 10/9/2018 MONDO AND SONS 24 5 Hours Minutes AC Branch Current AC Branch Current: Amps CO 120V Regulated Load in Standby Device Type Number of Devices volts volts feet amps amps volts Current (Amps) Resistance Per 1000 3.07 3.07 Total Current (Amps) FACP MAINBOARD SMOKE DETECTOR MONITOR MODULE PULL STATION ANNUNCIATOR 1 1 5 1 1 X X X X X 0.19000 0.00030 0.00035 0.00030 0.02000 = = = = = 0.19000 0.00030 0.00175 0.00030 0.02000 TOTAL STANDBY LOAD 0.21235 Regulated Load in ALARM Device Type Number of Devices I Device Current Current (Amps) Voltage at Drop from Device source 20.35 0.050 20.24 0.157 20.20 0.198 20.17 0.233 20.12 0.285 20.07 0.326 20.05 0.353 Total Current (Amps) FACP MAINBOARD SMOKE DETECTOR MONITOR MODULE PULL STATION ANNUNCIATOR FACP-1 (See Voltage Drop Calculations) FACP-2 (See Voltage Drop Calculations) FACP-3 (See Voltage Drop Calculations) FACP-4 (Spare) 1 1 5 1 1 1 1 1 1 X X X X X X X X X 0.25000 0.00650 0.00035 0.00030 0.02500 0.54800 0.83600 0.83700 0.00000 = = = = = = = = = 0.25000 0.00650 0.00175 0.00030 0.02500 0.54800 0.83600 0.83700 0.00000 TOTAL ALARM LOAD 2.50455 Battery Requirements Standby Load Required Standby Time in Hours Current (Amps) 0.21235 X 24.00000 = 5.09640 Alarm Load Required Alarm Time in Hours Current (Amps) 2.50455 X 0.08333 = 0.20871 Total Ampere Hours (before derating factor) 5.30511 Derating Factor X 1.2 TOTAL AMPERE HOURS REQUIRED = 6.36614 BATTERIES TO BE PROVIDED (2 - 12v) 8 AH FROM: FACP, NAC POWER, OR PREVIOUS DEVICE WALL MOUNTED Point to Point NAC Voltage Drop Calculation 10/9/2018 Project Name Circuit Number Nominal System Voltage Minimum Device Voltage Distance from source to 1st device Wire Gauge for balance of circuit Max Output Current Total Circuit Current End of Line Voltage MONDO AND SONS FACP-1 volts volts feet amps amps volts Wire Gauge Resistance Per 1000 3.07 3.07 20.4 16.0 15 14 14 3.00 0.548 20.05 Circuit is within limits I Device Current Distance previous device 15 Voltage at Drop from Device source 20.35 0.050 20.24 0.157 20.20 0.198 20.17 0.233 20.12 0.285 20.07 0.326 20.05 0.353 Percent Drop 0.25% 0.77% 0.97% 1.14% 1.40% 1.60% 1.73% Device 1 Device 2 Device 3 Device 4 Device 5 Device 6 Device 7 0.054 0.043 35 0.071 15 0.043 15 0.071 25 0.090 25 0.176 25 Totals 0.548 155 Notes: Wire resistance is doubled in the calculations for two wires (Positive and Negative). The voltage calculated to the last device must not be lower than the manufactures listed minimum operating voltage (IE: rated operating voltage 16-33 VDC (24 VDC nominal)). - Notes: Wire resistance is doubled in the calculations for two wires (Positive and Negative). The voltage calculated to the last device must not be lower than the manufactures listed minimum operating voltage (IE: rated operating voltage 16-33 VDC (24 VDC nominal)). Point to Point NAC Voltage Drop Calculation 10/9/2018 Project Name Circuit Number Nominal System Voltage Minimum Device Voltage Distance from source to 1st device Wire Gauge for balance of circuit Max Output Current Total Circuit Current End of Line Voltage MONDO AND SONS FACP-3 volts volts feet amps amps volts Wire Gauge Resistance Per 1000 3.07 3.07 20.4 16.0 65 14 14 3.00 0.837 19.62 Circuit is within limits I Device Current Distance previous device 65 Voltage at Drop from Device source 20.07 0.334 19.98 0.415 19.84 0.561 19.72 0.677 19.65 0.754 19.62 0.777 Percent Drop 1.64% 2.04% 2.75% 3.32% 3.69% 3.81% Device 1 Device 2 Device 3 Device 4 Device 5 Device 6 0.176 0.066 20 0.176 40 0.107 45 0.218 40 0.094 40 Totals 0.837 250 Notes: Wire resistance is doubled in the calculations for two wires (Positive and Negative). The voltage calculated to the last device must not be lower than the manufactures listed minimum operating voltage (IE: rated operating voltage 16-33 VDC (24 VDC nominal)). - CANDELA SELECT CEILING MOUNTED CANDELA SELECT TYPICAL L SERIES NOTIFICATION DEVICE WIRING DIAGRAM SCHEMATIC: NO SCALE TO: NEXT DEVICE OR EOL -4" MIN - Point to Point NAC Voltage Drop Calculation 10/9/2018 Project Name Circuit Number Nominal System Voltage Minimum Device Voltage Distance from source to 1st device Wire Gauge for balance of circuit Max Output Current Total Circuit Current End of Line Voltage MONDO AND SONS FACP-2 volts volts feet amps amps volts Wire Gauge Resistance Per 1000 3.07 3.07 20.4 16.0 35 14 14 3.00 0.836 19.72 Circuit is within limits I Device Current Distance previous device 35 Voltage at Drop from Device source 20.22 0.180 20.06 0.336 19.99 0.413 19.87 0.526 19.78 0.623 19.72 0.683 Percent Drop 0.88% 1.65% 2.02% 2.58% 3.06% 3.35% Device 1 Device 2 Device 3 Device 4 Device 5 Device 6 0.107 0.107 35 0.094 20 0.176 35 0.176 45 0.176 55 Totals 0.836 225 Notes: Wire resistance is doubled in the calculations for two wires (Positive and Negative). The voltage calculated to the last device must not be lower than the manufactures listed minimum operating voltage (IE: rated operating voltage 16-33 VDC (24 VDC nominal)). A/C SUPPLY OR RETURN DIFFUSER 4" MIN 12" MAX HEAT DETECTOR AUDIBLE/VISUAL 6" MIN. EVER LAND/OR VISUAL HERE L411:,=3 ONLY APPLIANCE WALL -MOUNTED HEAT DETECTOR 80"-96" TO LOWEST PART OF LENS EEO 90" MIN. WHERE CEILING HEIGHT ALLOWS AUDIBLE -ONLY APPLIANCES GENERAL NOTES: 1. SCOPE OF WORK: THIS PROJECT SHALL INCLUDE THE INSTALLATION AND MONITORING OF A NEW ADDRESSABLE FIRE ALARM SYSTEM. 2. THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. 3. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 4. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. 5. FIRE RATINGS SHALL BE MAINTAINED FOR ALL PENETRATIONS THROUGH FIRE -RATED CONSTRUCTION. 6. POWER FOR ALL FIRE ALARM PANELS AND FIRE ALARM POWER SUPPLIES MUST BE PROVIDED BY A DEDICATED AC BRANCH CIRCUIT. THE LOCATION OF THE BRANCH CIRCUIT BREAKER SHALL BE PERMANENTLY IDENTIFIED AT THE CONTROL UNIT AND SHALL HAVE A RED MARKING IN ACCORDANCE WITH NFPA 72. 7. POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN CABINET. ALL POWER -LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NONPOWER -LIMITED CIRCUIT WIRING. FURTHERMORE, ALL POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. 8. WHEN UTILIZING CLASS "A" CIRCUITS, SEPARATE OUTGOING AND RETURN CONDUCTORS OF CLASS "A" CIRCUITS BY A MINIMUM OF 12" WHERE RUN VERTICALLY AND 48" WHERE RUN HORIZONTALLY. 9. WHEN UTILIZING SHIELDED CABLE TIE SHIELDS THROUGH AND INSULATE AT EACH JUNCTION BOX. INSULATE AND TAPE BACK AT END. 10. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT MANUFACTURER FOR THE INTENDED PURPOSE. 11. SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN-UP IS COMPLETED AND FINAL. 12. LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. WALL -MOUNTED SMOKE DETECTORS SHALL BE LOCATED A MINIMUM OF 4" AND A MAXIMUM OF 12" FROM CEILING. 13. PROVIDE SYNCHRONIZATION OF ALL VISUAL NOTIFICATION APPLIANCE CIRCUITS. PROVIDE ALL REQUIRED SYNC MODULES. PROVIDE A MULTI -SYNC MODE SLAVE CONNECTION BETWEEN ALL SYNC MODULES. 14. VERIFY ALL FIELD SELECTABLE AUDIBILITY SETTINGS OF NOTIFICATION APPLIANCES WITH FIRE ALARM CONTRACTOR. 15. UPON COMPLETION OF THE FIRE ALARM SYSTEM INSTALLATION AND PROGRAMMING, THE INSTALLING CONTRACTOR SHALL PERFORM FINAL TESTING OF THE ENTIRE SYSTEM, PER ALL APPLICABLE CODES, AND SHALL COORDINATE AND PERFORM A FINAL FIRE ALARM SYSTEM INSPECTION. 16. PROVIDE OFF-SITE MONITORING AS REQUIRED BY THE INTERNATIONAL FIRE CODE, SECTION 907.6.5 AND THE LOCAL AUTHORITY HAVING JURISDICTION. 17. INSTALLING CONTRACTOR SHALL, PHYSICALLY, LABEL ALL INITIATING DEVICES AND NOTIFICATION APPLIANCE CIRCUIT END OF LINE (WHEN WIRING CLASS "B"). THESE LABELS SHALL BE IN PLACE PRIOR TO START-UP AND TESTING. 7//// \\\\\ CEI NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST POINT OF DETECTOR -i 36" MIN. I - MANUAL PULL I-5' MAX. - STATION WALL -MOUNTED CEILING MOUNTED SMOKE DETECTOR SMOKE/HEAT DETECTOR 42"-48" t FINISHED /'FLOOR DOOR WIDTH -LESS3=1"3 6 MAGNETIC DOOR HOLDER 2" MAX SIDE WALL NFINISHED WALL FIRE ALARM DEVICE MOUNTING HEIGHTS SCALE: NOT TO SCALE NICET III Fire Alarm Systems sFy Brady Haws) Signature Date: 10/9/2018 Fire Protection Engineering Technol Fire Alarm Systems Cert. No. 138751 Exp 5/1/2019 00 0 DESCRIPTION ISSUED FOR REVIEW & APPROVAL z O rn Lu O z 0 u z� CO CO CQ CO C\2 CoD CO C\2 Icle rx5' 1-4 l-4 LA w :RI Z CD CIDU CID CvD LCD CQ shop drawings created by 5794 W. 4600 So. Hooper, UT 84315 Office: 801.985.0410 www.unicod.net DCA Fire Alarm Desigr &-Drafting -Services MONDO AND SONS 1150 ANDOVER PARK E co co v• - co co 0) 4C J z w 1 0 z z 0 J V -J a V DRAWN CRL UNICAD JOB #18623 CHECKED BRADY B. HAWS NICET III 138751 DATE 10/09/2018 REVISION 0 SCALE 1/8"=1'-0" FA -2