HomeMy WebLinkAboutPP - 495 ANDOVER PARK EAST - RED DOT CORPORATION - PERMITS AND PLANS495 ANDOVER PARK EAST ASSOCIATED PERMITS 13-S-282 15-S-090 Otts31444 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 2623049094 Site Address: 495 Andover Park E Suite Number: Floor: Tenant Name: Red Dot Modular Property Owner's Name: HIGHLAND PARK PROPERTIES L New Tenant? CI - Yes © - No Mailing Address: 495 ANDOVER PARK E TUKWILA WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Travis Kinne Company Name: Fire Sprinklers Incorporated Day Telephone: 253-826-0099 Mailing Address: 1524 - 45th St E Suite 102 Sumner WA 98390 E-mail Address: travis@firesprinklersinc.com Total number of new/relocated devices or sprinkler heads: 2 City State Zip Fax Number: 253-826-1033 Valuation of Project (contractor's bid price): $ 8,397 Scope of Work (please provide detailed information): Add sprinklers to new modular office. PERMIT APPLICATION NOTE§, Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTHORIZED AGENT: Signature. Print Name: Travis Kinne Plan Permit App.doc Date: 11/6/2013 Day Telephone: 253-826-0099 1/2/13 TFD FP Form 8 FIRE SPRINKLERS INC. 1524 45th St E, SUITE 102 SUMNER,WA 98390 HYDRAULIC CALCULATIONS FOR Red Dot Modular 495 Andover Park E Tukwila, WA 98188 REMOTE AREA - 1 FILE NUMBER: 3346 DATE: 11/21/13 -DESIGN DATA - OCCUPANCY CLASSIFICATION: Ordinary Hazard Group I DENSITY: .15 gpm/sq. ft. AREA OF APPLICATION: 314 sq. ft. COVERAGE PER SPRINKLER: 256 sq. ft. Max NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 78.4 gpm TOTAL WATER REQUIRED (including hose): 178.4 gpm FLOW AND PRESSURE (@ BOR): 78.4 gpm @ 37.8 psi SPRINKLER ORIFICE SIZE: K=11.2 SPRINKLER TYPE: Tyco EC11 SPRINKLER TEMP: 155 NAME OF CONTRACTOR: FIRE SPRINKLERS INC DESIGN/LAYOUT BY: Travis Kinne AUTHORITY HAVING JURISDICTION: City of Tukwila CONTRACTOR CERTIFICATION NUMBER: FIRESI*988RJ CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 38011601 ) HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 . 'DATE? 11/21/2013AR\02-DESIGN\03-CALCULATIONS\O1-HYDRAULIC\3346 - CALC.SDF JOB TITLE: WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 0 PRESS. 0 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 150.0 20.0 8000.0 149.9 178.4 39.3 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 178.4 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 78.4 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) D1 7.7 K=11.20 12.4 39.5 D2 7.7 K=11.20 12.1 39.0 BL1 8.0 15.9 BL2 21.8 22.2 M1 21.8 22.5 TOR 21.8 22.5 BF1 3.0 30.7 BF2 3.0 36.7 BOR 0.5 - - - - 37.8 SRC -3.0 SOURCE 39.3 78.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE! 11/21/2013AR\02-DESIGN\03-CALCULATIONS\O1-HYDRAULIC\3346 - CALC.SDF JOB TITLE: PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -39.5 1.049 PL 1.02 PF 3.7 D1 7.7 11.2 12.4 39.5 14.7 120 FTG ET PE -0.1 BL1 8.0 0.0 15.9 0.0 0.457 TL 8.02 PV Pipe: 2 -39.0 1.049 PL 6.92 PF 4.0 D2 7.7 11.2 12.1 39.0 14.5 120 FTG E PE -0.1 BL1 8.0 0.0 15.9 0.0 0.447 TL 8.92 PV Pipe: 3 -78.4 1.380 PL 20.50 PF 12.2 BL1 8.0 0.0 15.9 0.0 16.8 120 FTG TL PE -6.0 BL2 21.8 0.0 22.2 0.0 0.429 TL 28.50 PV Pipe: 4 -78.4 2.469 PL 1.00 PF 0.3 BL2 21.8 0.0 22.2 0.0 5.3 120 FTG T PE 0.0 M1 21.8 0.0 22.5 0.0 0.025 TL 13.00 PV Pipe: 5 -78.4 7.981 PL 300.00 PF 0.0 M1 21.8 0.0 22.5 0.0 0.5 120 FTG 4L PE 0.0 TOR 21.8 0.0 22.5 0.0 0.000 TL 352.00 PV Pipe: 6 -78.4 7.981 PL 18.83 PF 0.0 TOR 21.8 0.0 22.5 0.0 0.5 120 FTG A PE 8.2 BF1 3.0 0.0 30.7 0.0 0.000 TL 49.83 PV Pipe: 7 FIXED PRESSURE LOSS DEVICE BF2 3.0 0.0 36.7 0.0 6.0 psi, 78.4 gpm BF1 3.0 0.0 30.7 0.0 Pipe: 8 -78.4 7.981 PL 3.00 PF 0.0 BF2 3.0 0.0 36.7 0.0 0.5 120 FTG ---- PE 1.1 BOR 0.5 0.0 37.8 0.0 0.000 TL 3.00 PV Pipe: 9 -78.4 7.981 PL 500.00 PF 0.0 BOR 0.5 0.0 37.8 0.0 0.5 120 FTG 4LG PE 1.5 SRC -3.0 SRCE 39.3 (N/A) 0.000 TL 556.00 PV NOTES (HASS): (1) Calculations were performed by the HASS 8.4 computer program under license no. 38011601 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.011 gpm and a maximum imbalance at any node of 0.098 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 ' DATE: 11/21/2013AR\02-DESIGN\03-CALCULATIONS\01-HYDRAULIC\3346 - CALC.SDF JOB TITLE: (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 16.8 ft/sec at pipe 3. (4) Available pressure at source node SRC under full flow conditions is 149.74 psi compared to the minimum required pressure of 20.00 psi. (5) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 10.00 5.00 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 2.469 6.00 12.00 4.00 14.00 7.00 1.00 10.00 10.00 12.00 7.981 18.00 35.00 13.00 45.00 12.00 4.00 31.00 31.00 35.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 ' DATE`. 11/21/2013AR\02-DESIGN\03-CALCULATIONS\O1-HYDRAULIC\3346 - CALC.SDF JOB TITLE: WATER SUPPLY ANALYSIS a O O O O a 3 0 G71 m a 0 O 0 150.00 psi Resid: E N N a E > > 0+ a la s+ 0+00 N a' U U k • N . W i • W to ra 0 a .-I a v w u ( a w p' 0 ami r•I CO •.1 M O >, •rlO M CO CO O rn Cr • > v 0 o ri N O O O O O 0 o O O O o O 0 O O O a v' N O ao w cr N ri r 4 H 1--1 0 4 (..Dw co,awEnmaw—am—i- 9 O 0 0 O w 0 O N N U) ri ro C4 o rn O N C E 0 s.1 ti -1 0) r -I ro O o w w tn —ro 3 wro u X o m O —0 ro ro 0 O to _ 0 O a o o N ro M A N O 0 O 0 z N 0 0 — w r -I N SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 • 'DATE: 11/21/2013AR\02-DESIGN\03-CALCULATIONS\01-HYDRAULIC\3346 - CALC.SDF JOB TITLE: WATER SUPPLY CURVE 156+ 0\ 1 \\ 143+ \ \\ \\ I \ 130+ \\ I \ \\ \\ 117+ \ \\ \\ I \ P104+ \\ R I E 1 \\ S I \\ S 91+ \ U 1 \\ R I \\ E 1 \ 78+ \\ ( I P 1 \\ S 1 \\ I 65+ \ ) 1 \\ \\ I \ 52+ \\ 1 \ \\ \\ 39X \\ \\ \ 26+ LEGEND \\ I \ I X = Required Water Supply 20.0 psi @ 8000 gpm-> * I 39.33 psi @ 178.4 gpm Flow Test Point 13+ 1 0 = Available Water Supply 149.89 psi @ 178.4 gpm " 1 " 0++-+---+----+ + + + + + + 16002400 3200 4000 4800 5600 6400 7200 8000 FLOW (GPM) 800-381-9312 Technical Services +1-401-781-8220 www.tyco-fire.com Series EC -11 & EC -14 — 11.2 and 14,0 K -factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Recessed Pendent Sprinklers General Description The TYCO Series EC -11 and EC -14 Extended Coverage Upright and Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accor- dance with standard installation rules (for example, NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 130 ft2 (12,1 m2) for standard coverage sprinklers used in ordinary hazard occupancies or 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. The Series EC -11 and EC -14 Sprinklers feature a UL and C -UL Listing that permits their use with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13, as well as a specific appli- cation listing for use under concrete tees. The Series EC -11 and EC -14 Extended Coverage Sprinklers have been fire tested to compare their performance to that of standard coverage spray sprin- klers. These tests have shown that the protection provided is equal to or more effective than standard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although corrosion resistant coated sprinklers passed standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/ chemical velocity should be consid- ered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. f/OTICE The Series EC -11 and EC -14 Extended Coverage Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protection Association, in addition to the standards of any author- ities uthorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. FEBRUARY 2012 Sprinkler Identification Numbers (SINs) TY5137 - Upright, 11.2K TY5237 - Pendent, 11.2K TY6137 - Upright, 14.0K TY6237 - Pendent,14.0K TY5137 is a redesignation for C5137, G1894, and S2510. TY5237 is a redesignation for C5237, G1893, and S2511. TY6137 is a redesignation for C6137, G1896, and S2610. TY6237 is a redesignation for C6237, G1895, and S2611. TFP22O TFP220 Page 2 of 8 1 -Frame 2 -Button 3 -Sealing Assembly 4 -Bulb 5 -Compression Screw 6- Deflector * Temperature rating is indicated on deflector " Pipe thread connections per ISO 7/1 can be provided on special request. WRENCH FLAT 3/4" NPT ** 2-7/16" (61,9 mm) UPRIGHT & PENDENT 1/2' (12,7 mm) J NOMINAL MAKE -IN UPRIGHT ESCUTCHEON PLATE SEATING SURFACE PENDENT FIGURE 1 SERIES EC -11 AND EC -14 EXTENDED COVERAGE SPRINKLERS 11.2 K -FACTOR UPRIGHT (TY5137) AND PENDENT (TY5237) 14.0 K -FACTOR UPRIGHT (TY6137) AND PENDENT (TY6237) — ASSEMBLY — CROSS SECTION Hazard Type Temperature Bulb Liquid Sprinkler Finish (See Note 5) Natural Brass Chrome Plated White* Polyester Lead Coated 135°F (57°C) Orange Upright K=11.2 (TY5137) 1, 2, 3", 4 155°F (68°C) Red Light Pendent 175°F (79°C) Yellow K=11.2 (TY5237) 200°F (93°C) Green 1, 2, 4 1, 2, 4 Refer to Table 0 for K=14.0 (TY6237) UL and C -UL 286°F (141°C) Blue 135°F (57°C) Orange 1, 2, 3, 4 Sensitivity Rating 155°F (68°C) Red Refer to Table C for Recessed Pendent FM Sensitivity K=11.2 (TY5237) 175°F (79°C) Yellow 1, 2, 4 Rating K=14.0 (TY6237) Withcutchtcheonn e E200°F Es N/A (93°C) Green 286°F (141°C) Blue Upright 135°F (57°C) Orange 1, 2, 3, 4 155°F (68°C) Red Ordinary K=11.2 (TY5137) K=14.0 (TY6137) 175°F (79°C) Yellow 1, 2, 3, 4 Pendent 200°F (93°C) Green Refer to Table B for K=11.2 (TY5237) 1, 2, 4 UL and C -UL K=14.0 (TY6237) 286°F (141°C) Blue Sensitivity Rating Recessed Pendent 135°F (57°C) Orange Refer to Table C for 155°F (68°C) Red FM Sensitivity K=11.2 (TY5237) Rating K=14.0 (TY6237) With Style 40 1, 2, 4 N/A 175°F (79°C) Yellow Escutcheon 200°F (93°C) Green Notes: 1. Listed by Underwriters Laboratories, Inc. (UL) 5. Where Polyester Coated or Lead Coated Sprinklers are noted to be 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Cor- rosion Resistant Sprinklers 3. Approved by Factory Mutual Research Corporation (FM) • Frame and Deflector only. Listings and approvals apply to color 4. Approved by the City of New York under MEA 177-03- E (Special Order) '" Pendent Only N/A: Not Available TABLE A — LABORATORY LISTINGS AND APPROVALS — TFP220 Page 3 of 8 Area Style Light Hazard 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) Ordinary Hazard 135°F 155°F 175°F 200°F (57°C) (68°C) (79°C) (93°C) 286°F (141°C) 14 x 14 Upright or Pendent Style 30 Recessed- Style 40 Recessed - - -- - - - - - - - -- - QR QR QR QR QR QR QR QR QR QR QR QR SR N/A N/A 18 x 18 Upright or Pendent Style 30 Recessed Style 40 Recessed QR* QR' QR` QR` QR' QR` OR* QR` QR' QR` N/A N/A N/A N/A N/A SR SR SR SR SR SR SR SR SR SR SR SR SR N/A N/A 18 x 18 Upright or Pendent Style 30 Recessed Style 40 Recessed QR` QR` QR` QR* QR* OR* QR* QR' QR` QR' N/A N/A N/A N/A N/A SR SR SR SR SR SR SR SR SR SR SR SR SR N/A N/A 20x20 Upright or Pendent Style 30 Recessed Style 40 Recessed QR` QR` QR` SR` SR' QR' QR* QR' SR` SR` N/A N/A N/A N/A N/A SR SR SR SR SR SR SR SR SR SR SR SR SR N/A N/A QR: Quick Response SR: Standard Response N/A: Not Applicable * Does not apply to Upright K=14.0 TABLE B SENSITIVITY RATING FOR UL AND C -UL LISTING OF SERIES EC -11 OR EC -14 SPRINKLERS (Refer to Table D for Permitted K-Factor/Area Combinations) Area Style Light Hazard 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) Ordinary Hazard 135°F 155°F 175°F 200°F (57°C) (68°C) (79°C) (93°C) 286°F (141°C) 14 x 14 Upright or Pendent Style 30 Recessed Style 40 Recessed - - -- - - - -- - - - -- - SR SR SR SR N/A N/A N/A N/A N/A N/A N/A N/A SR N/A N/A 16 x 18 Upright or Pendent Style 30 Recessed Style 40 Recessed QR' QR' N/A N/A N/A QR' QR' N/A N/A N/A N/A N/A N/A N/A N/A SR SR SR SR N/A N/A N/A N/A N/A N/A N/A N/A SR N/A N/A 18 x 18 Upright or Pendent Style 30 Recessed Style 40 Recessed QR' QR' N/A N/A N/A QR QR N/A N/A N/A N/A N/A N/A N/A N/A SR SR SR SR N/A N/A N/A N/A N/A N/A N/A N/A SR N/A N/A 20x20 Upright or Pendent Style 30 Recessed Style 40 Recessed QR' QR' N/A N/A N/A QR QR N/A N/A N/A N/A N/A N/A N/A N/A SR SR SR SR N/A N/A N/A N/A N/A N/A N/A N/A SR N/A N/A QR: Quick Response SR: Standard Response N/A: Not Applicable * Does not apply to Upright K=14.0 TABLE C SENSfi1VITY RATING FOR FM APPROVAL OF SERIES EC -11 OR EC -14 SPRINKLERS (Refer to FM Loss Prevention Data Sheet 2-8N for Permitted K-Factor/Area Combinations) TFP220 Page 4of8 Technical Data Approvals Refer to Table A for approval information on the TYCO Series EC -11 and EC -14 Sprinklers, as well as the TYCO Style 30 and Style 40 Two -Piece Recessed Escutcheons. The approvals apply to the service conditions indicated in the Design Criteria section. The TYCO Style 60 Two -Piece Flush Escutcheon (Figure 4) is UL Listed and FM Approved for use with the Series EC -11 and EC -14 Pendent Sprinklers. Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients • K =11.2 GPM/psiv2 (161,3 LPM/barv2) • K = 14.0 GPM/psiv2 (201,6 LPM/bar1I2) Temperature Ratings 135°F (57°C) to 286°F (141°C) Finish • Sprinkler: Refer to Table A. • Recessed or Flush Escutcheon: White Coated, Chrome Plated, and Brass -Plated Physical Characteristics Frame Bronze Button Bronze Sealing Assembly . . Bulb Compression Screw Deflector . Beryllium Nickel w/TEFLON Glass (3 mm dia.) Bronze Brass Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate and flow water. 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) t MOUNTING SURFACE CLOSURE El 1 MI II= ,lIII i0 1/2" (12,7 mm) 1/4' (6,4 mm) 1/8' (3,2 mm) i MOUNTING PLATE 1-3/8"(34,9 mm) 1-1/8" (28,6 mm) FIGURE 2 SERIES EC -11 AND EC -14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 -INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON Design Criteria The TYCO Series EC -11 and EC -14 Extended Coverage Sprinklers must only be installed in accordance with the applicable UL and C -UL Listing or FM Approval requirements as indicated below. Only the Style 30 or 40 Recessed Escutcheon is to be used for recessed installation, as applicable (Refer to Tables A, B, and C). UL and C -UL Listing Requirements • The Series EC -11 and EC -14 Sprinklers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for all sprinklers in the design area. • The Series EC -11 and EC -14 Sprinklers are permitted to be used with unobstructed or non-combus- tible obstructed ceiling construction as defined and permitted by NFPA 13. For example: - Unobstructed, combustible or non-combustible, ceiling construction with a deflector to ceiling/roof deck distance of 1 to 12 inches (25 to 300 mm). - Obstructed, non-combustible, ceiling construction with a deflector location below struc- tural members of 1 to 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). • The Series EC -11 and EC -14 Sprinklers, specifically tested and listed for non-combus- tible obstructed construction, are permitted to be used within trusses or bar joists having non-combustible web members greater than 1 inch (25.4 mm) when applying the 4 times obstruction criteria rule defined under "Obstructions to Sprinkler Discharge Pattem Development". • The minimum allowable spacing, to prevent cold soldering between Series EC -11 and EC -14 Sprinklers, is 8 feet (2,4 m) for upright sprinklers and 9 feet (2,7 m) for pendent sprinklers. • The Series EC -11 and EC -14 Sprinklers are to be installed in accordance with all other require- ments of NFPA 13 for extended coverage upright and pendent sprin- klers, For example; obstructions to sprinkler discharge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard, clearance to storage, etc. UL and C -UL Specific Application Listing Requirements for Installation under Concrete Tees The Series EC -11 and EC -14 Extended Coverage Upright and Pendent Sprinklers (TY5137, TY5237, TY6137 and TY6237) have a UL and C -UL Specific Application Listing for use under concrete tees when installed as follows: • The stems of the concrete tee construction must spaced at less than 7.5 feet (2,3 m) on center but A more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m); however, where the concrete tee length exceeds 32 feet (9,8 m), non- combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. • The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. • When the sprinkler deflectors are located higher than a horizontal plane 1 inch (25,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA 13 for extended coverage upright sprinklers applies. FM Approval Requirements The Series EC -11 and EC -14 Extended Coverage Sprinklers are to be installed in accordance with the applicable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non -storage and/or non-flam- mable or combustible liquid) occu- pancies. Information provided in the FM Loss Prevention Data Sheets relates to, but not limited to, hydraulic design, ceiling slope, and obstructions, minimum and maximum allowable spacing, and deflector -to -ceiling distance. These criteria may differ from UL and/ or NFPA criteria; therefore, the designer must review and become familiar with Factory Mutual requirements before proceeding with design. TRP220 Page 5 of 8 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING f MOUNTING SURFACE CLOSURE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) Rif 3/4" (19,1 mm) 1/4" (6,4 mm) 1/8' (3,2 mm) MOUNTING PLATE 1-3/8' (34,9 mm 7/8' (22,2 mm) FIGURE 3 SERIES EC -11 AND EC -14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 -INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON FACE OF SPRINKLER FITTING: 3/8" (9,5 mm) ABOVE TO 1/8' (3,2 mm) BELOW MOUNTING SURFACE ESCUTCHEON PLATE SEATING SURFACE: 1/4" (6,4 mm) ABOVE TO 1/2" (12,7 mm) BELOW MOUNTING SURFACE; 3/4" (19,1 mm) TOTAL ADJUSTMENT 2-7/8" DIA. (73,0 mm) 2-1/4• DIA. (57,2 mm) INTERNAL DIMENSIONS OF STYLE 80 ESCUTCHEON ACCOMMODATE CLASS 150 MALLEABLE IRON REDUCING SPRINKLER FITTING :=■I11- MIMI ■ CLOSURE 3/4" NPT MOUNTING PLATE MOUNTING 1/8" SURFACE (3,21 m) I 2-5/16' (58,7 mm) 1-13/16' (46,0 mm) FIGURE 4 SERIES EC -11 AND EC -14 PENDENT SPRINKLER ASSEMBLY WITH 3/4 -INCH TOTAL ADJUSTMENT STYLE 60 TWO-PIECE FLUSH ESCUTCHEON TFP220 Page 6 of 8 Installation The TYCO Series EC -11 and EC -14 Sprinklers must be installed in accor- dance with the following instructions: NOTICE Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A 3/4 inch NPT sprinkler joint should be obtained with a minimum -to -maximum torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over - tightening the Sprinkler. Re -adjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be installed with the deflector parallel to the mounting surface. Pendent sprin- klers must be installed in the pendent position, and upright sprinklers must be installed in the upright position. Step 2. After installing the Style 30, 40, or 60 mounting plate (or other escutcheon, as applicable) over the sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten upright or pendent sprinklers using only the W -Type 3 (End A) Sprinkler Wrench. When installing the pendent sprinkler with Style 30, 40, or 60 Escutcheon, wrench tighten the sprinkler using only the W -Type 22 Sprinkler Wrench. The wrench recess of the applicable sprin- kler wrench (Ref. Figure 5 and 6) is to be applied to the sprinkler wrench flats (Ref. Figure 1). Care and Maintenance The TYCO Series EC -11 and EC -14 Sprinklers must be maintained and serviced in accordance with the following instructions: NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Modified sprinklers must be replaced. Also sprinklers must be replaced that: • were damaged by dropping, striking, wrench twisting, wrench slippage, or the like; • are leaking or exhibiting visible signs of corrosion; • were exposed to corrosive products of combustion but have not operated, if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush; or • have a cracked Bulb or have lost liquid from the Bulb. Refer to the Installation section in this data sheet. Frequent visual inspections are recom- mended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. 'FITTING SIDE' TOWARDS SPRINKLER FITTING WRENCH RECESS (END "A") FIGURE 5 W -TYPE 3 SPRINKLER WRENCH t 0 ,®0 WRENCH RECESS -o WRENCH HEX FIGURE 6 W -TYPE 22 RECESSED SPRINKLER WRENCH The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards recognized by the Approval agency (for example, NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. TFP22O Page 7 of 8 Description Area Light Hazard 0.10 GPM/ft2 Group 1 Ordinary Hazard 0.15 GPM/ft2 Group II Ordinary Hazard 0.20 GPM/ft2 GPM PSI GPM PSI GPM PSI TY5137 (Ka11.2) Upright 14 x 14 - - 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 TY5237 (K=11.2) Pendell 14 x 14 - - 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 TY6137 (Ka14.0) Upright 14 x 14 N/A N/A - - - - 16 x 16 N/A 39 7.8 51 13.3 18 x 18 N/A N/A 49 12.3 65 21.6 20 x 20 N/A N/A 60 18.4 80 32.7 TY6237 (K=14.0) Pendell 14x14 - - - - - - 16 x 16 37 7.0 39 7.8 51 13.3 18 x 18 37 7.0 49 12.3 65 21.6 20 x 20 40 8.2 60 18.4 80 32.7 1 ft. = 0.3048 m 1 psi = 0.06895 bar 1 ft.2 =0.093 m2 1 GPM = 3.785 LPM 1 GPM/ft2 = 40.74 mm/min TABLE D FLOW CRITERIA FOR UL AND C -UL LISTING OF SERIES EC -11 AND EC -14 SPRINKLERS TFP220 Page 8 of 8 P/N 51 - XXX - X - XXX Sprinkler Finish Natural Brass 4 White Polyester 7 Lead Coated 9 Chrome -Plated Temperature Rating 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) TABLE E PART NUMBERS FOR SERIES EC -11 AND EC -14 SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Protection Products (TFPP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFPP. No warranty is given for products or components manufac- tured by companies not affiliated by ownership with TFPP or for products and components which have been subject to misuse, improper instal- lation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with appli- cable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFPP to be defective shall be either repaired or replaced, at TFPP's sole option. TFPP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFPP shall not be respon- sible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFPP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFPP was informed about the possi- bility of such damages, and in no event shall TFPP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. express or implied. including warranties of merchantability and fitness for a partic- ular purpose, This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name, description, and P/N. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies with NPT Thread Connections Specify (SIN), (K -Factor), (temperature rating), (Pendent or Upright) Extended Coverage Sprinkler with (finish), P/N. Refer to Table E Recessed Escutcheon, Two -Piece Specify Style (30 or 40) Two -Piece Recessed Escutcheon with (material or finish), P/N. Refer to Technical Data Sheet TFP770. Flush Escutcheon, Two -Piece Specify Style 60 Two -Piece Flush Escutcheon with (finish), P/N (specify). Refer to Technical Data Sheet TFP778. Sprinkler Wrenches Specify W -Type 3 Sprinkler Wrench, P/N 56-895-1-001. Specify W -Type 22 Recessed Sprinkler Wrench, P/N 56-665-7-001. Copyright 0 2001, 2012 Tyco Fire Protection Products. All rights reserved. TEFLON is trademark of The DuPont Corporation. Vico SIN 893 11.2K Pendent TY5237 894 11.2K Upright TY5137 895 14.01< Pendent TY6237 896 14.0K Upright TY6137 Sprinkler Finish Natural Brass 4 White Polyester 7 Lead Coated 9 Chrome -Plated Temperature Rating 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) TABLE E PART NUMBERS FOR SERIES EC -11 AND EC -14 SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Protection Products (TFPP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFPP. No warranty is given for products or components manufac- tured by companies not affiliated by ownership with TFPP or for products and components which have been subject to misuse, improper instal- lation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with appli- cable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFPP to be defective shall be either repaired or replaced, at TFPP's sole option. TFPP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFPP shall not be respon- sible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFPP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFPP was informed about the possi- bility of such damages, and in no event shall TFPP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. express or implied. including warranties of merchantability and fitness for a partic- ular purpose, This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name, description, and P/N. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies with NPT Thread Connections Specify (SIN), (K -Factor), (temperature rating), (Pendent or Upright) Extended Coverage Sprinkler with (finish), P/N. Refer to Table E Recessed Escutcheon, Two -Piece Specify Style (30 or 40) Two -Piece Recessed Escutcheon with (material or finish), P/N. Refer to Technical Data Sheet TFP770. Flush Escutcheon, Two -Piece Specify Style 60 Two -Piece Flush Escutcheon with (finish), P/N (specify). Refer to Technical Data Sheet TFP778. Sprinkler Wrenches Specify W -Type 3 Sprinkler Wrench, P/N 56-895-1-001. Specify W -Type 22 Recessed Sprinkler Wrench, P/N 56-665-7-001. Copyright 0 2001, 2012 Tyco Fire Protection Products. All rights reserved. TEFLON is trademark of The DuPont Corporation. Vico 11 Fire Sprinklers WA CL#FIREsr988RJ 1524 45`x' Street E, Suite 102, Sumner, WA 98390 • 253-826-0099 • Fax 253-826-1033 • www.firesprinklersinc.com May 22, 205 To: Tukwila Fire Department Attn: Al Metzler, Re: RedDOT 495 Andover Park E Tukwila, WA 98168 UKWIL. C FIRE DEPARTMENT 'opo a call 206-575-4407 and )ve this Fire Permit No. IS -S-090 Ind exact addmss ?or shut - 'own or re; on approval. Mr. Metzler, We are looking to demo an old paint booth sprinkler drop to allow the installation of some new electrical panels at the above referenced facility. The paint booth was removed some time in the past and the drop was left against the West wall of the facility and now conflicts with the new electrical panel locations. This would involve no sprinkler work just the removal of an unused 2'/z" drop. Sincerely, Greg Moffett, Sr. Estimator Fire Sprinklers, Inc. Greg@firesprinklersinc.com WASHINGTON STA'E CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Greg Moffett 4524-0902-C Level Fire Sprinklers Incorporated lRESI.988RJ Sign.tun PAN DECKING INSULATION SAMMY X -PRESS ALL THREAD ROD \ HANGER RING SAMMY X -PRESS HANGER TYPE SX NTS 1" BRANCHLINE- 1" POL— CEILING @J 7'-8" AFF -1" x'/" R.C. 3/." ECP TYPICAL DROP EXISTING WAREHOUSE SPACE (NO CHANGE TO EXISTING SPRINKLER SYSTEM) i - -- I I '----v.:,, � ; 1Y, � �� H I i 7-5 l/ _11c7 1 1 7'-11" \ -- 40 1 it iu rd 1 I�� r r,C)R.� FIRE SPRINKLER PLAN DRAWING SYMBOLS 118" =1'-0" SCALE:1/8" =1'-0" REVISIONS NTS SPRINKLER PIPE LEGEND: = EXISTING SPRINKLER PIPE (UNO) = NEW SPRINKLER PIPE (UNO) SPRINKLER HEAD LEGEND: = ADD NEW EC PENDENT SPRINKLER HEAD HYDRAULIC DESIGN INFO. 7–PAN DECKING — — --- _ = I -BEAM = _ _ -- - -- OFFICE SPACE ACT @ 7'-8" A SECTION FP1 CO SCALE: 1/8" =1'-0" HANGER LEGEND SCOPE OF WORK: ADD SPRINKLERS TO NEW MODULAR OFFICE. GENERAL NOTES: 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER DIMENSIONS AND MAINS, SHOWN THUSLY (1-6), WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET #13. 4. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 9. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. DESIGN NOTES: 1. DESIGN AND SPRINKLER SPACING TO BE PER NFPA #13 (LIGHT HAZARD). 2. PLAN SUBMITTAL TO AND APPROVAL BY THE CITY OF TUKWILA. 3. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY FSI. 4. TESTING PER NFPA #13 AND THE CITY OF TUKWILA. FIELD NOTES: 1. ALL NEW PIPE TO BE BLACK, SCHEDULE 40 WITH BLACK, DUCTILE IRON THREADED FITTINGS. 2. SPRINKLER HEADS ARE NOT REQUIRED TO BE LOCATED IN THE CENTER OF THE CEILING TILES. 3. ARMOVERS LONGER THAN 1-0" SHALL HAVE A HANGER. 4. TYPICAL HANGER TO BE SAMMY X -PRESS (UNLESS NOTED OTHERWISE). -Eleraisk ®- t j VICINITY PLAN SCALE: NTS SPRINKLER HEAD LEGEND MM. A- ALARM VALVE RISER - FLOW SWTICH RISER - DRY PIPE RISER - DELUGE/P.A. RISER 0 <Cc?' - FIRE DEPARTMENT CONNECTION ,tom. - WATER MOTOR GONG Ch - ELECTRIC BELL -o- +1 - FLEXIBLE GROOVED COUPLING - RIGID GROOVED COUPLING - THREADED PIPE COUPLING - CONTROL VALVE - CHECK VALVE - PIPE HANGER (SEE CHART) - SEISMIC BRACE (SEE CHART) - WELDED PIPE TAG O- BRANCHLINE NUMBER 9-0 1 (8-10) - PIPE SIZE & LENGTH - PIPE SIZE & LENGTH (CUT) 100 - HYDRAULIC NODE * 10'-10" FF Q - DATUM ION *0'-10"TSQ CENTERLINE OFPIPETO DECK MK DATE BY DESCRIPTION jl THIS SYSTEM IS I%S THIS SYSTEM IS NOT I HYDRAULICALLY DESIGNED V HYDRAULICALLY DESIGNED A U -HOOK "L" ROD SPRINKLER TYPE / SIN NUMBER MFG MODEL SYMBOL K -FAC THREAD TEMP FINISH CANOPY QTY - FLOW TEST - B COACH SCREW ROD STATIC: 150 PSI RESIDUAL: C "C" CLAMP N P TOGGLE NUT HDI -P EXTENDED COVERAGE PENDENT / TY5237 TYCO TY5237 11.2 3/4" 155° CHROME CHR/REC 2 GPM FLOWING: D TOP BEAM CLAMP W! STRAP R WEDGE ANCHOR DATE & TIME: EYE ROD S SAMMY SUPER SCREW (GST20) - SYSTEM DESIGN - F FLUSH SHELL SW SAMMY SIDEWINDER (SWG2G) REMOTE AREA: G CEILING FLANGE SX SAMMY X -PRESS DENSITY: H SIDE BEAM BRACKET T TRAPEZE MAX AREA/HEAD J "J" BOLT U UNISTRUT POST K -FACTOR K SHORT CLIP W TOTAL THIS SHEET 2 Fire Sprinklers EN WA CL# FIRESI*988RJ 1524 45th St E - Suite 102 Sumner, WA 98390 (253) 826-0099 PROJECT: Red Dot Modular 495 Andover Park E Tukwila, WA 98188 EMMEN C k 7,1 PVE 3 Thes2 pians T uk;;a Fire .rr_;i-City ACC=_ ...-rCJ-} ._ ._ - . - • `--- _ - _ _ - . E •. _ _ .. _ _- - :�--� _� N, ;I -_-- - -- - - - -:r = ---- :;ninspectio r, by adoptEd . _ the ar ai�i�19 or `o`otporated ocCcrtifica,00 r4 `oe• • � a� DESIGNER: Travis Kinne DATE: October 5, 2013 CONTRACT WITH: Red Dot Corporation 495 Andover Park E Tukwila, WA 98188 Terry Hart 206-409-1113 PAID NOV -7 2013 I•UiKWILA FIRE _4f z 7f17 /&7) - SCALE: As Noted HAZARD: As Noted AHJ: City of Tukwila JOB # 3346 SHEET # FP1 OF 1