Loading...
HomeMy WebLinkAboutPP - 401 BAKER BLVD - TOP POT DONUTS - PERMITS AND PLANS301 BAKER BLVD ASSOCIATED PERMITS D16-0243 16-S-250 13-S-006 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** PAID JAN 04 2013 TUKWILA FIRE King Co. Assessor's Tax No.: Site Address Baker Boulevard Suite Number: Floor: 1 Tenant Name: Fiat New Tenant? E - Yes ❑ - No Property Owner's Name: OB Properties Mailing Address: PO Box 726 Bellevue City CONTACT PERSON -if there are questions about the submittal. Name: Chris Seaman Company Name: Patriot Fire Protection, INC. WA 98009 State Zip Day Telephone: 253-284-3401 Mailing Address: 2707 70th Ave E Tacoma WA 98424 E-mail Address: chriss@patriotfire.com City State Zip Fax Number: 253-922-615 Valuation of Project (contractor's bid price): $ 2,200 Scope of Work (please provide detailed information): Add three sprinklers in new GWB ceiling cloud. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER R AUTHORIZED AGENT: Signature: Date:1.3.2013 Print Name: Chris Seaman Day Telephone: 253-284-3401 Plan Permit App.doc 5/14/10 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 301 Baker Blvd Tenant Name: Acura of Seattle Property Owner's Name: OB FIFE PROPERTY II L L C Mailing Address: King Co. Assessor's Tax No.: 0223100075 Suite Number: Floor: Ground New Tenant? ❑ - Yes X No 301 Baker Blvd Tukwila, WA CONTACT PERSON -if there are questions about the submittal. Name: Chase Auker Company Name: Archer Construction Inc . Mailing Address: 7855 S 206t h S t Kent , WA 98032 City State Zip Day Telephone: 253-872-7222 E-mail Address:CAuker@ArcherConstruction . corn City State Zip Fax Number: 253-872-7277 Contractor's City of Tukwila Business License number: BUS 0992634 Total number of new/relocated devices or sprinkler heads: 29 Valuation of Project (contractor's bid price): $ 5,600.00 Scope of Work (please provide detailed information): Add and relocate sprinklers as required for new walls and ceilings. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTH ZED AGENT: Signature: Date: 12-7-16 Print Name: Chase Auker Day Telephone: 253-872-7222 Plan Permit App.doc 8/22/14 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Permit No.: Date: Reviewer: Acura Of Seattle 301 Baker BI 16-S-250 December 13, 2016 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 21/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 6 16 02 45 16-s- Zs -O PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: A Type of Inspection: ti‘iii---i-- 76----)-4e.--w_I-4--. Address:,...,t-l-cuie—Pel----- Suite #: 01 ge-c-�� 13? -1/ I Contact Person: Special Instructions: Phone No.: R-ipproved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: yr3 Fire Alarm: '{&`z? C w F- QN4-1-1 Hood & Duct: Fl F-jN (2-aV . S 4'N ( 7-72-40 L /l- I Permits: Occupancy Type: -G-)14A-e-7-46.2z(frr(te,:g=z0101Z-4Thfe -67i3q3sii-d4 7?) c— & Lv 7Ni 7V2- -q fi- &tiffC7`s /1-L30IL- Lf /NSt-Yi2LC'=-41). Needs Shift Inspection: . Sprinklers: yr3 Fire Alarm: '{&`z? C w F- QN4-1-1 Hood & Duct: Monitor: S 4'N ( 7-72-40 L Pre -Fire: Permits: Occupancy Type: Inspector: pl"--L+— Date: 4,--heil Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECOR Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: h/, ,�� Sprinklers: Type of nsGon: Address:.,,// Suite #: of -" /e Conta Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: G�/'b 4 2/0 '" r -1-10‘,'S 0 / f1vp i•/;t/-'J . ,A55' — 7/G 7 CW 71U fi:.,b. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: i Inspector: -6 5 Date: j/y�/0 Hrs.: Z_ O $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECOR Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: AGk/VI Type of Inspection: CVS/' Address:,�t, �� Suite #: 30 I 6 key v Contact Person: Special Instructions: Phone No.: lyApproved per applicable codes. Corrections required prior to approval. COMMENTS: .1;7 �� rI — ✓I rfn ee - a r.e- ' - ,416P %e pG�- 2 —atom Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspectorf Date: 3A/xe Hrs.: ,S----- $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECOR Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Sprinklers: Fire Alarm: Type of Inspection: Cove/q" � Address: ��l Suite #: ! ��/ � cif �� Contact Person: Phone No.: Special Instructions: Approved per applicable codes. t>cCorrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: — niaS, 44 j„"` 4r,,,`'�o4, , O4 , iLlllS94- JM ' /.'.t�� 41163 •/.1/41 Occupancy Type: C0-� s //A"7 �j t �/ u li:�eS it/ '1 /sem or ,---7)1 4, .„ ,Iy 1 /Av# 2 ed.v. l.�ood 5A.,,..‘s hi 1i-#200113 1, -der" s I Z V le 7r" el GvDit- e-- /S t ,*C., lofea, - c• -e. ✓s A-E` /a/.Cri Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: -v ‹.--7 Date: /7/ 8 Hrs.: ( 6 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: g/41" Type ofInspection: Gt Address:...,Contact Suite #:....0P/ gt-/jy 3/vai. Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1L,„ si,., �� ThWC/ lc/s 04- lip �a✓err Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: G��� Mfg Date:?i)6//g Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 () 21'-0" GWB 12'-0" GWB Ri) LINE OF GWB CLOUD AT 13'-0" 12'-0" 21'-0" GWB • FIRE SPRINKLER PLAN SHOWROOM 18'-0" ACT SCALE: 1/8"=1'-0" (i) (4) GWB CUT r TEE INTO EXISTING DROP TYPICAL f•3 17'-0" GWB GENERAL NOTES 1. DENOTES NEW FIRE SPRINKLER PIPING. 2. @ DENOTES EXISTING FIRE SPRINKLER TO REMAIN. 3. TYPICAL DROP TO INCLUDE 4' FLEXHEAD. 4. TYPICAL HANGER TO BE 3/a" CS ROD. SCOPE OF WORK ADD SPRINKLER COVERAGE BELOW NEW CEILING CLOUD. Pack SITE r .-»�� �y re�3 mak- ate, :':e�ds_li1 rIRE D A�i` EN F coli 203-575-4e:07 and t1:.:; FTC Pamir.i Map data CL2013Google VICINITY MAP AA_ .44 1 HANGER LEGEND A B D E F "U" HOOK COACH SCREW ROD BM. CLAMP W/ "STRAP EYELET HILTI HDI—P STATE CERTIFICATION G H K M N P R S T U V W X Y Z Y � CL K N F 1 2 CEILING FLANGE SIDE BEAM BRACKET SHORT CLIP ALL THREAD ROD TOGGLE NUT POWDER DRIVEN STUD HILTI KB—III PIPE SPIKE SPRINKLER LEGEND SPRINKLE. ORIFICE SIZES AND TYPE w w LA I- U) 5 3 7 1 SPRAY 16 8 16 2 O 1/2" 1" 17 32 SPRAY • 3/4" 1 2 3 7 1 8 16 2 SIDEWALL 1/2" 1" 1" 2 - WAY EARTHQUAKE BRACE 4 - WAY EARTHQUAKE BRACE STRUCTURE TO CENTER LINE OF PIPE IN INCHES 1 2 TEMP RATING DRY TYPE 1" 1" FITTING LEGEND P PIPE -O -LET EcE 2 165° 212° 286° 350° 500° z a0 La J Z z Z a Na C, a_ z� LA0 -J 0 CO U, C7 Z �3 z0 0- 0 1/2" 4 1" 1" 1/2" 1" 4 1" 1/2" 1/2" F PLAIN END FIT FITTING APPROVAL REQUIRED SN GROOVED SHAPED NIPPLE CITY OF TUKWILA TSN THREADED SHAPED NIPPLE SPRINKLER HEAD LEGEND SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE HEAD FINISH ESC ETCH FINISH TEMP QTY RELIABLE G556 QR CONCEALER 5.6k BRASS WHITE 165'F 3 QUALITY CONTROL BY DATE APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PASPHLET NO. 13, 2007 EDITION. 4. $. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2007 EDITION 6. JOINING OF PIPE AND FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE 7. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2007 EDITION. WITH NFPA PAMPHLET NO. 13, 2007 EDITION. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. ALL WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY OTHERS 4. BY OTHERS PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA DESIGN PER NFPA 13, 2010 EDITION, FOR ORDINARY HAZARD GROUP II. PIPE NOTES 1. ALL THREADED PIPE TO BE BLACK SCH. 40. 2. ALL GROOVED PIPE TO BE BLACK SCH. 10. 3. ALL GROOVED COUPLINGS TO BE RIGID U.N.O. BY FLX. REVISIONS NO DATE BY DESCRIPTION CONTRACT WITH: JOHNSON DEVELOPMENT SUBMITTAL 1.3.2013 PROJECT NAME: FIAT OF SEATTLE 410 BAKER BOULEVARD TUKWILA, WA 98188 KEITH 206-999-9500 2707 70TH AVENUE EAST TACOMA, WA 98424 PATRIFP099CF WWW.PATRIOTFIRE.COM chriss@patriotfire.com TEL: (253) 926-2290 FAX: (253) 922-6150 DESIGNER CHRIS SEAMAN SHEET DATE 1.3.2013 JOB NO. 12-15459 1 OF 1 FP -1 C GLU-LAM OR BEAM MODEL #GST 20 ALL THREAD ROD HANGER H HANGER RING SAMMY SUPERSCREW 0 .- .4%-.)1C-WZ--.L anC.;spectior, narei -/ 3.-! / T i R f GLU-LAM OR BEAM 4//////////////mil. MODEL #SWG 20 ALL THREAD ROD HANGER RING HANGER G SAMMY SIDEWINDER e,.. 1••••••. • 48' al T T R A 0 48" 11-T1 C23 w T ar 1- LIJ 0 FIRE SPRINKLER TI PIPING PLAN T R os_o 48' I T LLJ NO WORK IN THS AREA SCALE: 1/8" = REVISIONS HANGERS HYDRAULIC DESIGN INFORMATION DATE DESCRIPTION BY A BEAM CLAMP W/ RETAINING STRAP AREA - CODE - HAZARD - SYSTEM TYPE B SIDE BEAM BRACKET C EYE SOCKET NUMBER 0 NUT & PLATE WASHER REMOTE - AREA DENSITY - INSIDE HOSE - OUTSIDE HOSE - AREA PER SPRINKLER E KWIK-BOLT SQ. FT. - GPM/SQ. FT. ALLOWANCE ALLOWANCE F HDI -P TOTAL SYSTEM _ REQUIREMENTS: G H SAMMY SIDEWINDER SAMMY SUPERSCREW HYDRAULIC DESIGN INFORMATION J COACH SCREW ROD K CEILING FLANGE L U -HOOK AREASYSTEM NUMBER - CODE - HAZARD - TYPE M SHORT STRAP N WALL BRACKET REMOTE - AREA SG Fr. - DENSITY GPM/SQ. FT. - INSIDE HOSE ALLOWANCE - OUTSIDE HOSE ALLOWANCE - AREA PER SPRINKLER - P Q TRAPEZE TOTAL SYSTEM - R REQUIREMENTS: ABBREVIATIONS AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO pF ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE RIGID COUPLING FLEXIBLE COUPLING k9R 48" WATERFLOW STATIC INFORMATION XX PSI RESIDUAL XX PSI GPM FLOWING XXXX GPM DATE & TIME XX/XXDOCXX PER: SYM • MAKE VICTAULIC MODEL V27 SI N# V2708 SPRINKLER SYMBOLS TYPE RECESSED PENDENT FINISH CHROME K -FAC. K=5.6 THREAD ORIFICE W. TEMP 155° CANOPY CHROME QTY 29 LOCATION: NOTES: CONSTRUCTION, INC SCOPE OF WORK: 1. ADD & RELOCATE REQUIRED SPRINKLERS FOR NEW CEILING & WALL LOCATIONS. 2. WET SYSTEMS TO BE DESIGNED PER NFPA #13 ORDINARY HAZARD. 3. PLAN SUBMITTAL TO & APPROVAL BY CITY OF TUKWILA. 4. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY ARCHER CONSTRUCTION, INC. 5. TESTING PER NFPA #13 & CITY OF TUKWILA. CLARIFICATIONS: 1. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED AT A MINIMUM OF 40°F (BY OTHERS) IN ORDER TO PREVENT THE PIPE FROM FREEZING. EXCLUSIONS: 1. TAXES OF ANY TYPE. 2. ELECTRICAL OF ANY TYPE. 3. UNDERGROUND PIPING OF ANY TYPE 4. STRUCTURAL VERIFICATION & ABATEMENT OF ANY TYPE. 5. LABELING, PREP FOR & PRIMING OR PAINTING OF ANY TYPE. 6. RELOCATION OF PIPE FOR WORK OF OTHER TRADES. DESIGN CRITERIA: 1. CRITERIA BASED ON NFPA #13 AND CITY OF TUKWILA CODES. FITTER NOTES: 1. HANGERS: * ALL PIPE HANGERS TO BE SAMMY SUPERSCREW. SEE HANGER DETAIL 'H' ON SHEET FPI. 2. MAXIMUM HEAD SPACING TO MATCH EXISTING 130 SQ. FT. 3. ALL THREADED PIPING TO BE SCHD 40 THREAD JOINED W/ THREADED FITTINGS. SPRINKLER HEADS: EXISTING 155°, Y2H, QR, PENDENT SPRINKLER R G = RELOCATE EXISTING 155°, %", QR, PENDENT SPRINKLER A = ADD NEW 155°, 1/2", QR, PENDENT SPRINKLER ales g‘n ry ice Iwo Jopa Organic I AREA OF WORK—. (i) 201 Baker Boulevard "11 min dn•le - ()Guitar Center REI Eirar.ch:!: :i•er Blvd carry VICINITY MAP SCALE: N.T.S. Acura of Seattle 301 Baker Blvd Tukwila, WA 98188 WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Scott Seibert 3322-0107-C Level 3 Arc - • ruction, Inc. CHEI*219DR _ Signature Date FIRE SPRINKLER TI PIPING PLAN PERMIT NO: - JOB NO: 816-170 AUTHORITY: CITY OF TUKWILA TOTAL PROJECT SPRINKLERS = 29 TOTAL SPRINKLERS THIS SHEET 29 FIRE SPRINKLER DIVISION 7855 S 206TH STREET, KENT, WA 98032 PHONE 253-872-7222 FAX 253-872-7277 CONTRACTOR: Foushee PHONE: FAX: at GM —724 DESIGNER: SEIBERT SCALE: 1/8" =1.-0" DATE: DECEMBER 6, 2016 REVISED / PLOTTED / / FP 1 OF 1 -. tilifiLA IF! Cc_ t — t-; i