Loading...
HomeMy WebLinkAboutPP - 151 ANDOVER PARK EAST - U.S. BANK - PERMITS AND PLANS151 ANDOVER PARK EAST ASSOCIATED PERMITS M10-097 10-F-197 WILA FIRE PREVENTION B ' • U 444 Andover Park Bast, Tukwila, WA 98188 - Phone 206575.4407 - Fax 206-575-4439 B -mail: tukidprv@oi.tukwila.aa.us CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETICC1TON SYSTEMS Fire elan System is ready for Fire Department acceptance testing. Failure of tet will result iq tin of the tattimUld additional= will be tied. Contractor is ale for supplying manpower for Filial Acceptance Test with two-way communications. Date 10 ii7-1 10 Permit # M (0 -- ®q7 %t9 F /47 7 Property Address l s i A hoot nes v- Cr She # •Zip Code QCT 1 S( City T Th WILA Name of Facility k. S ; A Occupied as Lk _ , AANI Owner or Representative installing Company (1/,u! A- S Phone # Installing. Contractor's i i ,,o D i Cr Airca—) 4.s -e City /4df Phone# VOt—Z / —S1o, Installer's Name (PRINT) ✓tre.L-e M10-11°4 c -c l) 0 License and/or Certificate rN r ,u / c i #- '1 R 0 2-4 General Contractor <t pti',s F t Electrical Contractor 4_ 1 L I n-`' Q& l k l FACP Equipment Manufacturer 6 t.eModel # This system has been installed, pro -tested and operates in accordance with the standards listed below and - was inspected by On (date) and includes the devices listed cm back. Circle all that apply: NFPA 72, Chapter 12 4 5 6 7 and/or IFC -SBC 907 NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions 'Manufacturer's Instructions • Other (specify) Tukwila City Ordinance Numbers 2050, 2051 UL Central Station Monitor ere- System is monitored by 4IA4e w- c SIGNED Date /m/iz! to System Firmware: Installed version Cheoksum Date Initial program Installation Date Revisions and Reasons Programmed by EQUIPMENT INSTALLED AND TESTED: Control Panel _ of_ Mak/Model Manual Station of— Make/Model Smoke Detectors of Make/Model Heat Detectors _ of_ Make/Modeln Duct Detector' 4 Of Make/Model r, p. AN Devices _ of _ Make/Model Audio Devices _ of _ Mike/model Visual Devices of _ Make/Model Auto Door Release of _ Make/Model • Trouble Indictors of Make/Model Battorias — — Readings Battery Full Load Charge • . 4) /ve4'CDC_Lp • Generator _ of _ Make/Model HVAC Controls _ of _ Make/Model. Fire Alarm Dialer _ of Make/Model Monitored by Annunciator of Make/Model ' ❑ SprinklerSystem. (Fire Alarm connections only) Water Flow Sw. — of Make/Model Valve Tamper Sw. _ of _ Make/Model PN _ of_ Make/Model • Elec. Alarm Bell — of Make/Model Automatic time Delay of Water Flow Alarm seconds. None Installed Do you meet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes No Test of alarm System on emergency power, satisfactory? Yes No _ Test Witnessed by Title Date . Comments: eddinsWire Alar Cacdticete doc Reviled: 1W28/04 TFD PP Fenn d110 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL'listed. `,' 1,* RTS151 UL 54011 RA100Z UL 52522 Ordering Information RTS151 KEY UL S2522 MHW UL 54011 APA151 UL S4011 MHR UL 54011 RT52-A05 UL S2522 A05 Part No. Description D4120 4 -wire photoelectric low -flow duct smoke detector Accessories D4S 4 -wire photoelectric serisor component only MHR Mini Horn, Red D4P120 4 -wire photoelectric power board component only, MHW 24 VAC/DC, 120 VAC 2D51 DST1 DST1.5 DST3 DST5 DST10 APA151 4 -wire conventional photoelectric sensor head Metal sampling tube duct width up to lft (0.3m) Mini Horn, White P48-21-00 End cap for metal sampling tubes RA100Z Remote annunciator alarm LED Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) RTS151 Remote test station Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) RTS151 KEY Remote test station with key lock Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) RTS2 - AOS Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) Remote annunciator with piezo alarm DH400 OE -1 Weatherproof enclosure ETX Metal exhaust tube duct width lft (0.3m) M02-04-00 Test magnet Multi -signaling accessory SYSTEM $ SENSOR' 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 02010 System Sensor Product specifications subject to change without notice Visit systemsensorcom for current product informaon, including the latest vernon of this data sheet A05-0419-002.2/10•#2305 ACCEPTED RI" Without Comments 0 As Noted in Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire ^revention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings�;after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Foal acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau, Date: 9'/O -10 By: 4'riS/ 1tifikMLA FIRE JEPARTharlat Please call: 575.4407 acrd give this job No. /O -F --19 7 and exact address for shot, 1,)w' or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. A CONWAY FIRE SAFETY WE DO IT RIGHT THE FIRST TIME TO: FROM: Fire Inspector Tracy Brown -Minnesota Conway Fire Attn: Al & Safety COMPANY: City of Tukwila. Fire Dept. DATE: 9-1-10 FAX NUMBER: 651-288-0777 TOTAL NO. OF PAGES INCLUDING COVER: PHONE NUMBER: 651-288-0790 SENDER'S REFERENCE NUMBER: RE: Approval Request YOUR REFERENCE NUMBER: URGENT X FOR REVIEW PLEASE COMMENT PLEASE REPLY PLEASE RECYCLE NOTES/COMMENTS: REQUEST FOR APPROVAL OR NOTICE OF WRI11'hN DESCRIPTION. SERVICE OF FIRE ALARM SYSTEM AT US BANK SEATTLE 151 ANDOVER PARK E, TUKWILA, WA. At US Bank Tukwila. 151 Andover Park East a duct detector in the rooftop penthouse HVAC unit was tied into the existing fire alarm system. The duct detector in place is a 4 wire photoelectric duct detector "Innovair flex". Please refer to attached cut sheet. The electric wiring was completed and terminated at the existing fire alarm control panel. The panel is a Firelite MS9200UD addressable panel. The duct detector is therefore on an individual panel address and will report as a zone 5 supervisory signal. Attached to the three (3) copies of this written description is the check for $75.00 for a City of Tukwila Fire Department permit and the requested cut sheet of the device in place. Please let me know if you have any additional questions. My Direct dial is shown above. Thank you very much. PAID SEP 0 9 2010 TUKWILA FI E� 575 MINNEHAHA AVE. W. ST. PAUL, MN 55103 TEL (952) 345-3473 FAX (952) 345-2499