Loading...
HomeMy WebLinkAboutPP - 320 ANDOVER PARK EAST STE 250 - WASHINGTON CITY INSURANCE AUTHORITY - PERMITS AND PLANS320 ANDOVER PARK EAST STE 250 ASSOCIATED PERMITS 12-F-021 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Site Address: 32-0 A-nd o'Jer ark_ E, **PLEASE PRINT** King Co. Assessor's Tax No.: Suite Number:2 S 0 Floor: 2 Tenant Name: IA/ I C A Property Owner's Name: Mailing Address: l • 6 � New Tenant? d- Yes ❑ - No �JI $h�/ i,c%1 C11.LnSurc,Ace ro'wldr+ 80X AS Qe��o� a. q�dS72 CONTACT PERSON -if there are questions about the submittal. Name: D& L MC Coy Company Name: �1 rbt, Et'e c.%r 1C_ Mailing Address: 4.10--(1 NL') /`tt4Je- 1 VIL, 9 "° City State Zip E-mail Address: Cle k t rby e lec 1 C6 M Fax Number: City State Zip Day Telephone: 2 S 3- S -q - 2 OUO Valuation of Project (contractor's bid price): $ 2A.5 n Scope of Work (please provide detailed information): Rob rh CCI k. 3 e.4 ts+i n 1-% 0 f r S' -'d PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHOR AGENT: Signature: Print Name:SCK-+th'L L - I 1 14/Sh 41( Plan Permit App.doc 5/14/10 Day Telephone: Date: 2-2 - Dc) la 2s3 - 2 ooc7 TFD FP Form 8 ;;,11:• 11 •i •1 F.E. EXIST. DOOR TO P.EMAI U E—' KITCHEN MR./SERVER' OFFICE CC CORRIDOR OFFICE OFFICE HALL OFFICE E E V E at OFFICE RELOCATE PASS THROUGH OFFICE WINDOW 4 COUNTER OFFICE REMOVE COOK, RETAIN SIDELIGHT L/ OFFICE CLOS. J04 FFICE RELOCATE DOOR, FRAME I HARDWARE 4 RELITE L REMOVE ALL EXIST. I CARPET AND BASE OFFICE REMOVE ALL ELECTRJC / DATA OUTLETS * SWITCHES IN PARTITIONS TO BE REMOVED. RETAIN CONNECT! CI FOR NEW. r - E4 18'-0" E 33'-0" REMOVE ALL EXIST. CARPET AND BASE J I I REMOVE DOOR / OFFICE �- RELOCATE DOOR, FRAME I HARDWARE ll PARTITIONS, T"P. REMOVE SELECT I I IL 24'-0" 9 Nana A completed, signed, Tukwila Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the ,t,adequacy of design rests totally with the designer, "AdOltions, deletions or revisions to these drawings after th,IS•date will void this acceptance and will require a rbsubmittai of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire PreVention Bureau. Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection ystems. Failure of test will result in a Re -inspection Fee and termination of the testing. TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact adthess for shut- down or restoration approval. SUITE 270 DEMO PLAN SUBFLOOR SCALE EXIST. CARPET PAD T -MOLDING TRANSITION STRIP 7 NEW CARPET CARPET TO CARPET FLOOR TRANSITION DETAIL SCALE DEMOLITION NOTES 1. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING UTILITIES AND EQUIPMENT, RELOCATE EXISTING UTILITIES AS REQUIRED FOR NEW WORK. NOTIFY OWNER OF CONFLICTS. 2. PROTECT ALL EXISTING CONSTRUCTION THAT IS TO REMAIN FROM DAMAGE DURING DEMOLITION. BRACE AND SUPPROT ALL WORK UNTIL IT IS PROPERLY REMOVED OR INCORPORATED INTO NEW CONSTRUCTION. 3. THE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR COORDINATING WORK WITH BUILDING MANAGEMENT. 4. ADJACENT PROPERTIES, STREETS AND WALKS ARE TO BE PROTECTED FROM DAMAGE AT ALL TIMES. 5. DURING THE COURSE OF WORK, IF THE EXISTENCE OF ASSESTOS OR MOLD IN THE STRUCTUI.E OR BUILDING IS OBSERVED, THEN CONTRACTOR SHALL PROMPTLY NOTIFY OWNER AND ARCHITECT REGARDING REMOVAL OR ENCAPSULATION OF THE ASBESTOS OR MOLD MATERIAL AND CONTRACTOR SHALL NOT PERFORM ANY WORK PERTINENT TO THE ASBESTOS OR MOLD MATERIAL PRIOR TO RECEIPT OF SPECIAL INSTRUCTIONS FROM OWNER THROUGH THE ARCHITECT. G. REMOVE ALL ELECTRICAL AND MECHANICAL AND PLUMBING WORK ATTACHED TO WALLS OR REPLACE/PLACE IN WALL CAVITY, REMOVE ALL FIRE EXTINGUISHERS OR CABINETS IN CONFLICT WITH NEW WORK FOR RELOCATION. PATCH AND PAINT WALLS TO REMAIN A5 NEEDED. 7. REMOVE SELECTED INTERIOR PARTITIONS OR PORTIONS THEREOF, DOORS AND RELITES AS INDICATED. RETAIN DOORS AND RELITES FOR RELOCATION. 8. IDENTIFY AND TAG ALL ELECTRICAL WIRING 4 DEVICES, PHONE WIRING AND DEVICES, COMPUTER CABLING, ETC. THAT IS TO BE RETAINED. REMOVE ALL OTHER WIRING 4 DEVICES NOT REQUIRED FOR NEW WORK. ALL SURFACE MOUNTED WIRING IS TO BE REMOVED OR RELOCATED INSIDE PARTITIONS. PATCH 4 REPAIR WALLS AS REQUIRED TO RECEIVE NEW FINISHES. 8. REMOVE ALL FLOORING 4 BASE IN EXISTING SUITE 270. PREPARE SURFACE FOR NEW CARPET, DEMOLITION NOTES SCALE: r 9 " N/A ------- EXISTING CONSTRUCTION =a NEW CONSTRUCTION = = CONSTRUCTION TO BE DEMOLISHED OR RELOCATED ROOM NUMBER AREA # OF OCCUPANTS OCCUPANT LOAD EXITING FLOOR PLAN LEGEND SCALE DUPLEX RECEPTACLE. 'N' INDICATES NEW RECEPTICLE TO BE INSTALLED AS " PART OF THIS WORK. ALL OTHER RECEPTACLES SHOWN WITH 'E' OR OTHERWISE ARE EXISTING TO REMAIN. • COMBINATION TELEPHONE/DATA OUTLET. THOSE SHOWN ADJACENT -TO -- NEW ELECTIR,CAL OUTLETS ARE NEW WORK. ALL OTHER OUTLETS SHOWN WITH AN 'E' OR OTHERWISE ARE EXISTING TO REMAIN.' ExIT SIGN, CEILING MOUNTED, ARROW(5) INDICATES DIRECTION IF SHOWN" EXIT SIGN, WALL MOUNTED, ARROW(5) INDICATES DIRECTION IF SHOWN' • 5EE ALSO REFLECTED CEILING PLAN NOTE: ALL NEW WALL PLATES ARE TO MATCH BUILDING STANDARD ELECTRICAL LEGEND IEXIST. CONF./TRAINING ROOM WEST ENTRY W IA SPACE SATE 104 SUITE 103 SUITE 102 LOBBY I OF - EXIST. 5IDWALK EXI T. PARK NG AIN EXIS . PARKING 1ST FLOOR EXIT PLAN SCALE SCALE: N/A (i O OFF. OFF. DATE 1 PERMIT 12-29-11 REVISIONS • PAID FEB -2 2012 TUKWILA FIRE Ill] IL) CHECKED BY: PROJECT NUMBEll . I 21.125.00 I t1 LI II 1__ ' \` E II -- I _ ., F.E. SIE -- ] %" ,,� ." F.E. ., FJQDT, REMAIN DOOR TO `�� \� E I 1 — �,\ ti ' / \4/ STAIRWEL - ,) Al J �■ .. , -V----- 11.) 5'-0" r \ // N ,r REMOVE EXIST. T I INFILL OPENING WHE �- 7,E N SIGN IF IN `� PLAC EXIST. HALL DOOR IS : i, • VED , n •• N TO MAT )01,,,,,/,'�� V0011 Al EXIST. DOO I` TO. / `K.1/'1 OFFICE OFFICE OFFICE OFFICE REMAIN O`FICE 2 3 4 r ; LOBBY III I3 ., G r ki2cF. „ m' �Ke)00 I1 ° 4 } um` r-7,1 r. I� a EMERGEN EQUIPME' AS REQUIRED f OR Al -IJ W/EXIST. REL THROUGH NTER. PROVID WHERE COUNT RELOCATIC i INFILL OPENING WHERE WINDOW IS REMOVEP 'ASS WITH THROUGH " VON.11FRELOCATE EXIS`ING OFFICE WALL'TO /' i�I er\ RELOCATED DOOR, FRAME P LIGHT 4 FIRE ALARM MATCH ADJ. `/ ON THIS WALL I, 12 OFFIC, EXIST. CARPET , HARDWARE THE FIRE MARS`1ALL 1 BASE . 756C 6)CR, BASE ALIGN NEW PARTITION --- --- �� �, • , y a . 1W/EXIST. 4 GWB. ! ElN 4 Q. � ilk *'.I► • CE ALIGN NEW WALL ca - �F 7 FRAME RELOCATED PASS bl RELOCATED DOCK, HARDWARE * REI.ITE Z `� 4.•4 IDE NEW C RPET TO CA- 'ET TRANSITION ST- - WINDOW 4 COL OFFICE .,EPN OFFICE OFFICE \ 1 CONF. v- -RE REQUIRED PER 14 NEW COUNTER I I I 0 9 EXIST. SWITCH, TYP. 8 C s7 - • 2.0 DAMAGED DURING / EXIST. OUTLET, "YP. IT NEW ELEC. 4 TE-E/DATA E E E' , !1 WALL TO WINDOW DTL' OUTLET,TYP. �, n v f • 4 a Er Ir ., ,. t A � E4 E4 ` t 21' - 9" � 4 9.0" 18.0' 33'-0" 24'-0" . SOOPE DOES NOT INCLUDE ANY NEW !Dom, WINDOWS OR DOOR HARDWARE. DOORS/WINDOWS IN NEW OFFICE AREAS ARE TO BE RELOCATED FROM OFFICES THAT AM DEMOLISHED IN THE SAME SPACE. 2. FOR WALL TYPES SEE DETAIL 3. ALL NEW INTERIOR FINISHES INCLUDING PAINT, CARPET AND BASE ETC. ARE TO BE COORDINATED WITH BUILDING MANAGEMENT. CONTRACTORI5 TO PROVIDE AND INSTALL REQUIRED FINISHES ON ALL AREAS OF WITH DEMOLITION. 4. ALL CASEWORK AND FIXTURES ARE EXISTING OR PROVIDED BY TENANT. 5. PROVIDE FIRE EXTINGUISHERS AND CABINETS AS REQUIRED BY FIRE MARSHALL. COORDINATE LOCATIONS WITH AND RECIEVE APPROVAL FROM ARCHITECT PRIOR TO INSTALLATION. REUSE OF EXISTING UNITS 15 ACCEPTABLE. NEW EXTINGUISHERS AND CABINETS TO MATCH EXISTING. ASSUME ONE NEW UNIT WILL BE . REQUIRED. REVIEWED FOR CODE COMPLIANCE APPROVED IMMINMEN KITCHEN OFF. OFF. JAN 0 5 2012 City of Tukwila UILDING DIVISION SUITE 270 FLOOR PLAN SCALE I 13.'' The Dr iftm Ar chitee-0,p, cY 7983 Leary liVay, Yr Redmond, iyA (425) 881-7p90 ITE ER IS N. 6. WHERE DOORS, FRAMES, RELITES, DOOR HARDWARE, LIGHT FIXTURES, DIFFUSERS ETC. ARE REMOVED AND RELOCATED, CONTRACTOR SHALL CLEAN AND SERVICE EQUIPMENT PRIOR TO REINSTALLATION. NOTIFY ARCHITECT AND BUILDING MANAGER OF NON WORKING EQUIPMENT THAT REQUIRES SERVICE BEYOND BASIC CLEANING AND MAINTENANCE OR REQUIRES REPLACEMENT. 7. COORDINATE W/ OWNER AND INSTALL BARRIER FREE SIGNS ROOM SIGNS WHERE REQUIRED BY CODE AND LOCAL JURISDICTION. 8. GC TO PATCH AND REPAIR ALL EXISTING WALLS FULL HEIGHT TO RECEIVE NEW FINISHES. ., 9. AT WALL INFILL AREAS, NEW WALL TO MATCH EXISTING INCLUDING SOUND BATT OR OTHER INSULATION. CONTRACTOR TO MATCH ADJACENT EXISTING PAINT AND BASE MATENAL.5. 10. RELOCATE ANY FIRE ALARM, HORN STROBES OR OTHER EMERGENCY EQUIPMENT IN CONFLICT WITH NEW WORK AS DIRECTED BY THE AHJ AND OR FIRE MARSHALL. I I . PROVIDE NEWDUPLD( ELECTRICAL AND COMBINATION TELE/DATA OUTLETS WHERE INDICATED AND A5 REQUIRED BY CODE FROM EXISTING CIRCUITS. NEW WALL PLATES TO MATCH EXISTING BUILDING STANDARD. PLAN NOTES SCALE: EXISTING DOOR T REMAIN (NOT AN OFF, 209 S.F. OFF. OFF. OFF. DATE 1 PERMIT 12-29-11 REVISIONS • PAID FEB -2 2012 TUKWILA FIRE HALL EN OFF 0 RNA! OPEN OFF TTL C liEc 29 2011 :RMIT CENTER EXIT ACCESS: COMMON PATH OF TRAVEL MAXIMUM PER IBC 1014.3.1 =100' PROPOSED COMMON PATH OF TRAVEL IN SUITE 270 15 < I 00' TOTAL MAXIMUM TRAVEL DISTANCE PER IBC I 0 I G. I = 300' FOR BUILDINGS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM TOTAL PROPOSED TRAVEL DISTANCE USING STAIR #2 = 180' OCCUPAN1- LOAD: OFFICES 1,703 5F/100 = 18 CONFERANCE 319/15 = 22 TOTAL OCCUPANT LOAD = 40 PER IBC I 015.1, SPACES W/ <49 OCCUPANTS MAY HAVE ONE EXIT 1,703 S.F. 100118 OCC. CONF. 15122 OCC. CORRESTIO WV- 386 2ND FLOOR EXIT PLAN • THIS DOCUMENT REPRESENTS A PROPRIETARY 6E841 OWNED BY THE ARCHITECT AND SHALL NOT BE USED ON OTHER PROJECTS FOR ADDITIONS TO THIS PROJECT OR FOR COMPLETION OF THIS PROJECT BY OTHERS EXCEPT BY PRIOR AGREEMENT IN WRITING. Revision Schedule NO. TYPE REVISION DATE 1 PERMIT 12-29-11 REVISIONS • PAID FEB -2 2012 TUKWILA FIRE ISSUE DATE: 12/6/11 DRAWN BY: • SMF CHECKED BY: PROJECT NUMBEll . I 21.125.00 I t1 SHEET NUMBER A2.0 1