FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
4it**PLEASE PRINT**
Max)E n?
Mailing Address: u
K
King Co. Assessor's Tax No.:
Suite Number: Floor:
New Tenant? ❑ - Yes 14o
CONTACT PERSON -if there are questions about the submittal.
Name:
4oAk_se-IA.
S
Company Name:
1City1/1-
City
Mailing Address: lei Lo 5- L AA.pc, 5 Iiik
City
0. CO V�-
E-mail Address: it k.(',L,tA_S..e.Vk
Day Telephone:
State Zip
6160 3P -
Le Zip
Fax Number:
Contractor's City of Tukwila
NICET III number: Business License number:
Total number of new/relocated devices or sprinkler heads:4h
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information): Gi.Lttue
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name:
Date:
Day Telephone:
Plan Permit App.doc 8/22/14 TFD FP Form 8
*ILA
•1;4 City of Tukwila
.1908
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188-7661
(206) 575-4404
John W. Rants, Mayor
March 29, 1994
Fire Department Review
Control #B94-0067
(510)
Re: Body Circle Jewelry - 13000 East Marginal Way South
Dear Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. The total number of fire extinguishers required for
your establishment is calculated at one extinguisher for
each 3000 sq. ft. of area. The extinguisher(s) should be
of the "All Purpose" (2A, 10B:C) dry chemical type. Travel
distance to any fire extinguisher must be 75' or less.
(NFPA 10, 3-1.1)
Extinguishers shall be installed on the hangers or in
the brackets supplied, mounted in cabinets, or set on
shelves (NFPA 10, 1-6.9), and shall be installed so
that the top of the extinguisher is not more than 5
feet above the floor. (NFPA 10, 1-6.9)
Extinguishers shall be located so as to be in plain
view (if at all possible), or if not in plain view,
they shall be identified with a sign stating, "Fire
Extinguisher", with an arrow pointing to the unit.
(NFPA 10, 1-6.3) (UFC 10.505A)
Fire extinguishers require monthly and yearly
inspections. They must have a tag or label securely
attached that indicates the month and year that the
inspection was performed and shall identify the
company or person performing the service. (NFPA 10,
4-3, 4-4 and 4-4.3) Every six years, dry chemical and
halon type fire extinguishers shall be emptied and
subjected to the applicable recharge procedures. (NFPA
10, 4-4.1) If the required monthly and yearly
City of Tukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188-7661
(206) 575-4404
Page number 2
John W. Rants, Mayor
inspections of the fire extinguisher(s) are not
accomplished or the inspection tag is not completed, a
reputable fire extinguisher service company will be
required to conduct these required surveys. (NFPA
10A-4-4)
Maintain fire extinguisher coverage throughout.
2. No point in an unsprinklered building may be more than
150 feet from an exit, measured along the path of travel.
(UBC 3303(d))
3. Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort. Exit
doors shall not be locked, chained, bolted, barred, latched
or otherwise rendered unusable. All locking devices shall
be of an approved type. (UFC 12.106(c))
Dead bolts are not allowed on auxiliary exit doors
unless the dead bolt is automatically retracted when
the door handle is engaged from inside the tenant
space.
Obstructions, including storage, shall not be placed
in the required width of an exit, except projections
as permitted by the Building Code. Exits shall not be
obstructed in any manner and shall remain free of any
material or matter where its presence would obstruct
or render the exit hazardous. (UFC 12.104(a))
Exit hardware and marking shall meet the requirements
of the Uniform Fire Code. (UFC 12.106-12.111)
4. A fire alarm system is required for this project. The
fire alarm system shall meet the requirements of NFPA 72
and City Ordinance #1646. An approved automatic sprinkler
system may be installed in lieu of a fire alarm system.
Maintain square foot coverage of detectors per
manufacturer's specifications in all areas including:
closets. elevator shafts. too of stairwells. etc.
City of Tukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188-7661
(206) 575-4404
Page number 3
(NFPA 72E, 2-7.4) (UFC 10.501(a))
John W. Rants, Mayor
All new fire alarm systems or modifications to
existing systems shall have the written approval of
The Tukwila Fire Prevention Bureau. No work shall
commence until a fire department permit has been
obtained. (City Ordinance #1646) (UFC 10.503)
Remote alarm and trouble annunciation indication is
required if the control panel is not visible from the
main entrance. (City Ordinance #1646) (UFC 10.501(a))
When the control panel is located inside a room, the
door to the room shall have a sign with one -inch
letters which reads "Fire Alarm" or "Fire Alarm
Control". (City Ordinance #1646)
5. All electrical work and equipment shall conform
strictly to the standards of The National Electrical Code.
(NFPA 70)
6. In combustible construction, fire blocking and
draftstopping shall be installed to cut off all concealed
draft openings (both vertical and horizontal). (UBC 2516,
11 (F))
Fire doors, fire windows and fire dampers shall have a
label or other identification showing the fire
protection rating. Such label shall be approved and
shall be permanently affixed.
Required fire resistive construction, including
occupancy separations, area separation walls, exterior
walls due to location on property, fire resistive
requirements based on type of construction, draft stop
partitions and roof coverings shall be maintained as
specified in the Building Code and Fire Code and shall
be properly repaired, restored or replaced when
damaged, altered, breached, penetrated, removed or
imorooerly installed. (UFC 10.601)
City of Tukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188-7661
(206) 575-4404
Page number 4
John W. Rants, Mayor
This review limited to speculative tenant space only -
special fire permits may be necessary depending on detailed
description of intended use.
Yours truly,
The Tukwila Fire Prevention Bureau
cc: T.F.D. file
ncd
City of Tukwila
Fire Department
;,—
A„.„1„.411)G 2 5 1994
John W. Rants, Mayor
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
f ✓ Z.)?--f/r,'
�
Project Name ,g�")c"I / � /� r� �jl�?--f/ ' L'I
Address 1 0 fri [,t ea J -. s
y
Retain current inspection schedule
XNeeds shift inspection
Thomas P. Keefe, Fire Chief
Permit No. ,e24/---60(0
Suite #
XApproved without correction notice
Approved with correction notice issued
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre -Fire:
Permits:
Authorized Signature
j /SV
]/2-a
FINALAPP.FRM T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
SEP 8 1994
TUKWILA FIRE DEPARTMENT
FIRE PREVENTION BUREAU
(206) 575-4407
CORRECTION NOTICE/REINSPECTION FEE
BUSINESS NAME: �e')cify Civc/e LJ/AS Lj DATE: EL -,1S ' j1
ADDRESS: / r/1,1109s > �/ �� f BLDG: SUITE: APT:
TYPE OF INSPECTION: fv( INSPECTOR: 4;-/0 BLDG. PERMIT #: ,G7c' '
CONTACT PERSON: /N41 17-;001/4 1/j PHONE : 2454-(7')
ACTION REQUIRED:
r /4,v;c/6 "Ad / 60/
C Y 4YYV
fiVe /•��`''
CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY:
72
A $40.00 Reinspection Fee is required and must be received by the
Tukwila Fire Department, 444 Andover Park East, Tukwila, Wa. 98188
prior to reinspection. Make checks payable to the City of Tukwila
and provide the YELLOW copy of this notice with payment.
FAILURE TO PAY the reinspection fee within seven 7 days may result
in the issuance of a citation for Failure to Comply.
For Office Use Only:
Date Paid:
Receipt #:
File Code:
W -Finance Y -File P -Contractor
WP:CORREFEE.FRM
T.F.D. Form F.P. 100
Scope Of Work
Project Name: Body Circle
13000 E Marginal Way S
Tukwila, WA 98168
For: Fire Alarm System Replace Fire panel
By: TYCO Integrated Security
19625 62nd Ave S
Kent, WA 98032
License ID
Contact: Wendy Coile
wcoile@tyco.com
Telephone: 253-796-7231
Fax: 253-796-7267
New Quantity Model Description
1
3
1
Scope of Work:
9050UD-A8 Fire Lite Addressable Fire Panel
MMF-300 Addressable Module Monitor
SD355 Smoke Detector
1. Replace existing NAPCO Fire Panel and Replacing with Addressable Fire Lite Fire
Panel
2. Install addressable smoke detector above Fire Panel
3. Install Addressable Module Monitor's for each existing zone's (1,2, and 3)
4. This is initial phase to ensure customer is monitored, once installed, will replace
all original devices with new addressable devices to bring system up to code
5. Utilizing the existing two phone lines
6. Test fire alarm panel to ensure it is communicating to TYCO Integrated Security
central station.
7. The fire alarm signal will communicate back to TYCO Integrated Security UL
Central Station.
8. TYCO Integrated Security is responsible for the annual testing and servicing of the
fire alarm equipment.
PAID
11 2011
TUKWILA FIRE
rc eve)—
90T0 UD-AS
YYI YH F -,3o()
mm=-3op��P,a
bOV
rYWYW -300
MS-9050UD(E)
Fire Alarm Control Panel
with DACT
DF -52418:E1 • A1-20
Flre•uremarms
by Honeywell
Addressable
General
The Fire•Lite MS-9050UD(E) is a Fire Alarm Control Panel
(FACP) and Digital Alarm Communicator/Transmitter (DACT)
combined into one circuit board. This compact, intelligent
addressable control panel supports up to 50 addressable
devices of any type of detectors and modules. With an exten-
sive list of powerful features, the MS-9050UD programs just like
Fire•Lite's larger products, yet fits into applications previously
served only by conventional panels.
The MS-9050UD's integral DACT transmits system status
(alarms, troubles, AC Toss, etc.) to a Central Station via the pub-
lic switched telephone network. It also allows remote and local
programming of the control panel using the PK -CD Upload/
Download utility. In addition, the control panel may be pro-
grammed or Interrogated off-site via the public switched tele-
phone network. Any personal computer with Windows"' 95 or
greater, and compatible modem with a speed of 14.4 kbps or
faster and Fire•Lite Upload/Download software kit PK -CD, may
serve as a Service Terminal. This allows download of the entire
program or upload of the entire program, history file, walk -test
data, current status and system voltages.
The power supply and all electronics are contained on a single
circuit board supported on a new quick install chassis and
housed in a metal cabinet. Available accessories include local
and remote upload/download software, remote annunciators,
and reverse polarity/city box transmitter. (4XTMF)
New options Include a UL listed printer, PRN -6F and the new
IPDACT Internet Monitoring module.The FlreWatch Series Inter-
net monitoring modules IPDACT-2 and IPDACT-2UD permit
monitoring of alarm signals over the Internet, saving the monthly
cost of two telephone lines. Although not required, the second-
ary telephone line may be retained providing backup communi-
cation over the public switched telephone line.
NOTE: Unless otherwise specified, the term MS-9050UD is used
in this data sheet to refer to both the MS-9050UD and the MS-
9050UDE FACPs. For MS-905OUDC, refer to DF -60445.
Features
• Listed to UL Standard 864, 9th edition.
• Auto -program (learn mode) reduces installation time.
Reports two devices set to the same address.
• On -board DACT.
• Two Independently programmable Style Z (Class A) or Style
Y (Class B) NAC circuits.
• Selectable strobe synchronization for System Sensor, Whee-
lock, and Gentex devices.
• Remote Acknowledge, Silence, Reset and Drill via address-
able monitor modules.
• Two programmable relays and one fixed trouble relay.
• Built-in Programmer.
• Telephone Line Active LEDs.
• EIA -232 PC Interface.
• Integral 80 -character LCD display with backlighting.
• Real-time clock/calendar with automatic daylight savings
control.
• History file with 500 event capacity.
• Automatic detector sensitivity testing (NFPA 72 compliant).
• Automatic device type -code verification.
5
• Point trouble identification.
• Waterflow selection per module point.
• Alarm verification selection per detector point.
• Maintenance alert warns when smoke detector dust accumu-
lation is excessive.
• One-person audible or silent walk test with walk -test log and
printout.
• System alarm verification selection per detector point.
• PAS (Positive Alarm Sequence) and Pre -signal per point
(NFPA 72 compliant).
• Up to eight ANN -BUS annunciators
• Remote Acknowledge, Alarm Silence, Reset and Drill via
addressable modules or remote annunciator.
• Upload/Download (local or remote) of program and data via
integral DACT.
SLC COMMUNICATION LOOP
• Single addressable SLC loop which meets NFPA Style 4, 6
and 7 requirements.
• 50 addressable device capacity (any combination of address-
able detectors and modules).
• Compatible with Fire•Lite's addressable devices (refer to SLC
Wiring Manual).
NOTIFICATION APPLIANCE CIRCUITS (NACS)
• Two independently programmable output circuits. Circuits
can be configured for the following outputs:
— Style Y (Class B)
— Style Z (Class A)
— Door Holder Service (cannot be used for notification appliances)
— Aux Power Source (cannot be used for notification appliances)
• Silence Inhibit and Autosilence timer options.
• Continuous, March Time, Temporal or California code for
main circuit board NACs with two-stage capability.
• Selectable strobe synchronization per NAC.
• 2.5 A total power for NACs.
NOTE: Maximum or total 24VDC system power shared between
all NAC circuits and the ANN -BUS is 2.7 A.
DF -52418:E1 •1/27/12 — Page 1 of 4
MS-9050UD
Fire Hann
Control Panel
S0355
Photo Detector
AD355
Adapt Detector
ANN -80
Printer
Gey
ANN-S/PG
1.1
Graphic LED Module
ANN -UO
H355M355RM355Nf
Heat Detector
MDF -300
Dual Monitor Module
SD355T
Photo/flxnnal
Relay Module 111
ANN-RLY
P2R
Strobe
P2R
Strobe
111
P2R
Strobe
MW -300
Monitor Module
Pow Supply
FOPS-24FS6
FCPS-24FS8
MMF-302
2 -Wire Detector
Monitor Module
Multi -Modules
• CRF -300-6 Six -Relay Control Module
• CMF -300-6 Six -Circuit Supervised Control Module
• MMF-302-6 Six -Zone Interface Module
• MMF-300-10 Ten -Input Molitor Module
FIRE
BG-12LX Addressable
Manual Pull Station
44111;t:
Beam Detector
BEAM -335/(S)
MS-9050UD
ADDRESSABLE FIRE ALARM
CONTROL PANEL
PROGRAMMING AND SOFTWARE
• Autoprogram (learn mode) reduces installation time.
• Custom English labels (per point) may be manually entered
or selected from an Internal library file.
• Two programmable Form -C relay outputs.
• 20 software zones.
• Continuous fire protection during online programming at the
front panel.
• Program Check automatically catches common errors not
linked to any zone or input point.
• OFFLINE PROGRAMMING: Create the entire program in
your office using a Windows based software package(order
programming kit PK -CD, containing PS -Tools, separately).
Upload/download system programming locally.
User interface
LED INDICATORS
• AC Power (green)
• Fire Alarm (red)
• Supervisory (yellow)
• Trouble (yellow)
• Alarm Silenced signals (yellow)
KEYPAD
• 16 key alpha -numeric pad
• Acknowledge/Step
• Alarm Silenced
• Drill (Manual Evacuate)
• Reset (lamp test)
Product Line Information
MS-9050UD(E): Combination DACT/Fire Alarm Control Panel
with one SLC loop. Includes main circuit board with display,
chassis with transformer, backbox with door, plastic bag contain-
ing screws, cables, key, etc., manual. (For MS-905OUDC, refer
to DF -60445.)
PK -CD: Contains PS -Tools programming software for Win-
dows0-based PC computer (cable not Included).
DP -51050: Optional dress panel for the MS-9050UD.
TR -CE: Optional trim ring for semi -flush mounting.
BB -2F: Optional cabinet for one or two modules.
BB -6F: Optional cabinet for up to six modules mounted on
CHS -6 chassis.
BB -26: Battery backbox, holds up to two 25 AH batteries and
CHG-75.
BB -55F: Battery box, houses two 55 AH batteries
CHS -6: Chassis, mounts up to six multi -modules in a BB -6F
cabinet.
CHG-75: Battery charger for lead -acid batteries with a rating of
25 to 75 AH.
CHG-120F: Remote battery charging system for lead -acid bat-
teries with a rating of 55 to 120 AH. Requires additional BB -55F
for mounting.
BAT Series: Batteries, see data sheet DF -52397.
PRT/PK-CABLE: Cable printer/personal computer Interface
cable.
PRN -6F: UL listed compatible event printer. Uses tractor -fed
paper.
IPDACT, IPDACT2/2UD Internet Monitoring Module: Mounts
in bottom of enclosure with optional mounting kit (PN IPBRKT).
Connects to primary and secondary DACT telephone output
ports for Internet communications over customer provided ether -
Page 2 of 4— DF -52418:E1 •1/27/12
net intemet connection. Requires compatible Teldat Visoralarm
Central Station Receiver. Can use DHCP or static IP. (See data
sheet df -52424 for more information.)
IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure.
IPSPLT: Y -adaptor option allows connection of both panel dialer
outputs to one IPDACT-2/2UD cable input.
AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in
turn, mounts to the FACP chassis. Use AC-TRMBLK when wire
nuts are not allowed for AC connections to the transformer.
OPTIONAL MODULES
4XTMF Reverse Polarity Transmitter Module: Provides a
supervised output for local energy municipal box transmitter,
alarm and trouble. Includes a disable switch and disable trouble
LED.
ANN -SEC: Optional secondary ANN -BUS interface module.
Note: Used only with firmware 3.0 or higher.
COMPATIBLE ANNUNCIATORS
ANN -80(-W): Remote LCD annunciator mimics the information
displayed on the FACP LCD display. Recommended wire type is
un-shlelded. (Basic model is red; order -W version for white; see
DF -52417.)
ANN -UO: LED Driver Module provides connections to a user
supplied graphic annunciator. (See DF -52430.)
ANN -LED: Annunclator Module provides three LEDs for each
zone: Alarm, Trouble, and Supervisory. Ships with red enclo-
sure. (See DF -60241.)
ANN-RLED: Provides alarm (red) indicators for up to 30 input
zones or addressable points. (See DF -60241.)
ANN-RLY: Relay Module provides 10 programmable Form -C
relays. Can be mounted inside the cabinet. (See DF -52431.)
ANN-S/PG: SerialParallei Printer Gateway module provides a
connection for a serial or parallel printer. (See DF -52429.)
ADDRESSABLE DEVICES
All feature a polling LED and rotary switches for addressing.
CP355: Addressable low -profile ionization smoke detector.
SD355: Addressable low -profile photoelectric smoke detector.
SD355T: Addressable low -profile photoelectric smoke detector
with thermal sensor.
SD355R: Remote test capable addressable photoelectric
smoke detector for use with DNR(W) duct detector housing.
H355: Fast -response, low -profile heat detector.
H355R: Fast -response, low -profile heat detector with rate -of -
rise option.
H355HT: Fast -response, low -profile heat detector that activates
at 190°F/88°C.
AD355: Low -profile, intelligent, "Adapt" multi -sensor detector
(B350LP base included).
BEAM355: Intelligent beam smoke detector.
BEAM355S: Intelligent beam smoke detector with integral sen-
sitivity test.
D355PL: InnovairFlex low -flow non -relay duct -detector housing;
includes SD355R.
DNR: InnovairFlex low -flow non -relay duct -detector housing.
(Order SD355R separately.)
DNRW: InnovairFlex low -flow non -relay duct -detector housing,
with NEMA -4 rating. Watertight. (Order SD355R separately.)
MMF-300: Addressable Monitor Module for one zone of nor-
mally -open dry -contact initiating devices. Mounts in standard
4.0" (10.16 cm.) box. Includes plastic cover plate and end -of -line
resistor. Module may be configured for either a Style B (Class B)
or Style D (Class A) IDC.
MDF -300: Dual Monitor Module. Same as MMF-300 except it
provides two Style B (Class B) only IDCs.
MMF-301: Miniature version of MMF-300. Excludes LED and
Style D option. Connects with wire pigtails. May mount in device
backbox.
MMF-302A: Similar to MMF-300A. Addressable Monitor Module
for one zone of conventional two -wire detectors. Requires reset -
table 24 VDC power. Refer to the Device Compatibility Docu-
ment for listed compatible devices and quantity limitation.
CMF -300: Addressable Control Module for one Style Y2 (Class
E3/A) zone of supervised polarized Notification Appliances.
Mounts directly to a 4.0' (10.16 cm.) electrical box. Notification
Appliance Circuit option requires external 24 VDC to power noti-
fication appliances.
CRF -300: Addressable relay module containing two Isolated
sets of Form -C contacts, which operate as a DPDT switch.
Mounts directly to a 4.0" (10.16 cm.) box, surface mount using
the SMB500.
BG-12LX: Addressable manual pull station with interface mod-
ule mounted inside.
1300: This module isolates the SLC loop from short circuit condi-
tions (required for Style 6 or 7 operation).
SMB500: Used to mount all modules except the MMF-301 and
M301.
MMF-300-10: Ten -input monitor module. Mount one or two mod-
ules in a BB -2F cabinet (optional). Mount up to six modules on a
CHS -6 chassis in a BB -6F cabinet.
MMF-302-6: Six -zone interface module. Mount one or two mod-
ules In a BB -2F cabinet (optional). Mount up to six modules on a
CHS -6 chassis in a BB -6F cabinet.
CMF -300-6: Six -circuit supervised control module. Mount one or
two modules in a BB -2F cabinet (optional). Mount up to six mod-
ules on a CHS -6 chassis in a BB -6F cabinet.
CRF -300-6: Six -relay control module (Form -C relays). Mount
one or two modules in a BB -2F cabinet (optional). Mount up to
six modules on a CHS -6 chassis In a BB -6F cabinet.
NOTE: For more information on Compatible Addressable Devices
for use with the MS-9050UD, see the following data sheets (docu-
ment numbers): AD355 (DF -52386), BG-12LX (DF -52013), CMF -
300 -6 (DF -52365), CRF -300-6 (DF -52374), CMF/CRF Series (DF -
52130), CP355 (DF -52383), H355 Series (DF -52385), 1300 (DF -
52389), MMF-300 Series/MDF-300 (DF -52121), MMF-300-10
(OF -52347), MMF-302-6 (DF -52356), SD355/SD355T (DF -
52384).
ADDRESSABLE DEVICE ACCESSORIES
End -of -Line Resistor Assembly (R -47K and R -3.9K): The
47k ohm assembly supervises the MMF-300, MDF -300, MMF-
301, and CMF -300 module circuits. The 3.9k ohm assembly
supervises the MMF-302 module circuit. These resistors are
included with each module.
Power Supervision Relay: Supervises the power to 4 -wire
smoke detectors and notification appliances.
Wiring Requirements
While shielded wire is not required, it is recommended that all
SLC wiring be twisted -pair to minimize the effects of electrical
interference. Refer to the panel manual for wiring details.
DF -52418:E1 • 1/27/12 — Page 3 of 4
SYSTEM SPECIFICATIONS
System Capacity
• Intelligent Signalling Line Circuits 1
• Addressable device capacity 50
• Programmable software zones 20
• Annunciators 8
Electrical Specifications
AC Power: MS-9050UD 120 VAC, 60 Hz, 3.0 A. MS-905OUDE:
240 VAC, 50 Hz, 1.5 A. Wire size: minimum 14 AWG (2.00 mm2)
with 600 V insulation. Nonpower -limited, supervised.
Battery: Two 12 V 18 AH lead -acid batteries. Battery Charger
Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of two
18 AH batteries.)
Communication Loop: Supervised and power -limited.
Notification Appliance Circuits: Terminal Block provides con-
nections for two NACs, Style Y (Class B) or Style Z (Class A).
Special Application power. Power -limited, supervised circuitry.
Maximum signaling current per circuit: 2.5 A. End -of -Line Resis-
tor: 4.7k ohm, / watt (P/N 71252 UL listed) for Style Y (Class B)
NAC. Refer to the Fire•Lite Device Compatibility Document for
listed compatible devices.
Two Programmable Relays and One Fixed Trouble Relay:
Contact rating: 2.0 A 0 30 VDC (resistive), 0.5 A 0 30 VAC
(resistive). Form -C relays, nonpower -limited, nonsupervised.
Cabinet Specifications
Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72'
(1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65"
(42.29 cm.) wide x 5.25' (13.34 cm.) deep. Trim Ring (TR -CE):
22.00' (55.88 cm.) high x 19.65' (49.91 cm.) wide.
Shipping Specifications
Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.)
high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep.
Temperature and Humidity Ranges
This system meets NFPA requirements for operation at 0 —
49°C/32 —120°F and at a relative humidity 93% t 2% RH (non -
condensing) at 32°C t 2°C (90°F ± 3°F). However, the useful
life of the system's standby batteries and the electronic compo-
nents may be adversely affected by extreme temperature ranges
and humidity. Therefore, it is recommended that this system and
its peripherals be installed in an environment with a normal room
temperature of 15 — 27°C/60 — 80°F.
NFPA Standards
The MS-9050UD(E) complies with the following NFPA 72 Fire
Alarm Systems requirements:
— LOCAL (Automatic, Manual, Waterflow and Sprinkler
Supervisory).
— AUXILIARY (Automatic, Manual and Waterflow) (requires
4XTMF).
— REMOTE STATION (Automatic, Manual and Waterflow)
(Where a DACT is not accepted, the alarm, trouble and
supervisory relays may be connected to UL 864 listed
transmitters. For reverse polarity signaling of alarm and
trouble, 4XTMF is required.)
— PROPRIETARY (Automatic, Manual and Waterflow).
— CENTRAL STATION (Automatic, Manual and Waterflow,
and Sprinkler Supervised).
— OT, PSDN (Other Technologies, Packet -switched Data Net-
work)
Agency Listings and Approvals
The listings and approvals below apply to the basic MS-
9050UD(E) control panel. In some cases, certain modules may
not be listed by certain approval agencies, or listing may be in
process. Consult factory for latest listing status.
• UL: S624
• FM approved
• CSFM: 7165-0075:210
• MEA: 442-06-E
NOTE: See DF -60445 for ULC -listed model.
FireLite® Alarms® and System Sensor® are registered trademarks of
Honeywell International Inc. Microsoft® and Windows® are registered
trademarks of the Microsoft Corporation.
02012 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
ISO 9001
CERTI F1E�
MAMA & MMIIFAfl1YIM
QUALITY SYSTEMS
This document is not intended to be used for Installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.
www.firelite.com
Made in the U.S. A
Page 4 of 4— DF -52418:E1 • 1/27/12
MMF-300(A) Series,
MDF -300
Addressable Monitor Modules
DF -52121:E • E-325
Fire°LITe°ALarms
by Honeywell
Addressable Devices
General
Four different monitor modules are available for Fire•Lite's
intelligent control panels to suit a variety of applications. Moni-
tor modules are used to supervise a circuit of dry -contact input
devices, such as conventional heat detectors and pull stations,
or monitor and power a circuit of two -wire smoke detectors
(MMF-302(A)).
MMF-300(A) is a standard -sized module (typically mounts to a
4" [10.16 cm] square box) that supervises either a Style D
(Class A) or Style B (Class B) circuit of dry -contact input
devices.
MMF-301(A) is a miniature monitor module a mere 1.3" (3.302
cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that super-
vises a Style B (Class B) circuit of dry -contact input devices. Its
compact design allows the MMF-301(A) to be mounted in a
single -gang box behind the device it monitors.
MMF-302(A) is a standard -sized module used to monitor and
supervise compatible two -wire, 24 volt, smoke detectors on a
Style D (Class A) or Style B (Class B) circuit.
MDF -300(A) is a standard -sized dual monitor module used to
monitor and supervise two independent two -wire Style B
(Class B) dry -contact initiating device circuits (IDCs) at two
separate, consecutive addresses in intelligent, two -wire sys-
tems.
LfeSpeedTM is a communication protocol developed by
Fire•Lite Engineering that greatly increases the speed of com-
munication between analog intelligent devices. Intelligent
devices communicate in a grouped fashion. If one of the
devices within the group has new information, the panel CPU
stops the group poll and concentrates on single points. The
net effect is response speed greater than five times that of
other communication protocols.
MMF-300(A) Monitor Module
• Built-in type identification automatically identifies this device
as a monitor module to the control panel.
• Powered directly by two -wire SLC loop. No additional
power required.
• High noise (EMF/RFI) immunity.
• SEMS screws with damping plates for ease of wiring.
• Direct -dial entry of address: 01 — 159 on MS -9600 series
panels, 01 — 99 on other compatible systems.
• LED flashes during normal operation and latches on steady
to indicate alarm.
The MMF-300(A) Monitor Module is intended for use in intelli-
gent, two -wire systems, where the individual address of each
module is selected using the built-in rotary switches. It pro-
vides either a two -wire or four -wire fault-tolerant Initiating
Device Circuit (IDC) for normally -open -contact fire alarm and
supervisory devices. The module has a panel -controlled LED
indicator. The MMF-300(A) can be used to replace M300(A)
modules in existing systems.
MMF-300(A) APPLICATIONS
Use to monitor a zone of four -wire smoke detectors, manual
fire alarm pull stations, waterflow devices, or other normally -
open dry -contact alarm activation devices. May also be used
to monitor normally -open supervisory devices with special
OMINIMOM
Melt. ammo
ACGOollre
.:10111101*
11101.111.11111MAMMY•
1•M -•H IMP WI.1111" Mc MAIM WM
,....,.ILAM 110•Inell
MMF-300(A) (Type H)
supervisory indication at the control panel. Monitored circuit
may be wired as an NFPA Style B (Class B) or Style D (Class
A) Initiating Device Circuit. A 47K Ohm End -of -Line Resistor
(provided) terminates the Style B circuit. No resistor is required
for supervision of the Style D circuit.
MMF-300(A) OPERATION
Each MMF-300(A) uses one of the available module
addresses on an SLC loop. It responds to regular polls from
the control panel and reports its type and the status (open/nor-
mal/short) of its Initiating Device Circuit (IDC). A flashing LED
indicates that the module is in communication with the control
panel. The LED latches steady on alarm (subject to current
limitations on the loop).
MMF-300(A) SPECIFICATIONS
Nominal operating voltage: 15 to 32 VDC.
Maximum current draw: 5.0 mA (LED on).
Average operating current: 375 NA (LED flashing), 1 com-
munication every 5 seconds, 47k EOL.
Maximum IDC wiring resistance: 1500 Ohms.
Maximum IDC Voltage: 11 Volts.
EOL resistance: 47K Ohms.
Temperature range: 32°F to 120°F (0°C to 49°C).
Humidity range: 10% to 93% noncondensing.
Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x
1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x
2.125" (5.398 cm) deep box.
MMF-301(A) Mini Monitor Module
• Built-in type identification automatically identifies this device
as a monitor module to the panel.
• Powered directly by two -wire SLC loop. No additional
power required.
• High noise (EMF/RFI) immunity.
DF -52121:E • 07/30/2015 — Page 1 of 4
• Tinned, stripped leads for ease of wiring.
• Direct -dial entry of address: 01 — 159 on MS -9600 series
panels, 01 — 99 on other compatible systems
The MMF-301(A) Mini Monitor Module can be installed in a
single -gang junction directly behind the monitored unit. Its
small size and light weight allow it to be installed without rigid
mounting. The MMF-301(A) is intended for use in intelligent,
two -wire systems where the individual address of each module
is selected using rotary switches. It provides a two -wire initiat-
ing device circuit for normally -open -contact fire alarm devices.
The MMF-301(A) can be used to replace M301(A) modules in
existing systems.
MMF-301(A) APPLICATIONS
Use to monitor a single device or a zone of four -wire smoke
detectors, manual fire alarm pull stations, waterflow devices,
or other normally -open dry -contact devices. May also be used
to monitor normally -open supervisory devices with special
supervisory indication at the control panel. Monitored circuit/
device is wired as an NFPA Style B (Class B) Initiating Device
Circuit. A 47K Ohm End -of -Line Resistor (provided) terminates
the circuit.
MMF-301(A) OPERATION
Each MMF-301(A) uses one of the available module
addresses on an SLC loop. It responds to regular polls from
the control panel and reports its type and the status (open/nor-
mal/short) of its Initiating Device Circuit (IDC).
MMF-301(A) SPECIFICATIONS
Nominal operating voltage: 15 to 32 VDC.
Average operating current: 350 pA, 1 communication every
5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC
Shorted).
Maximum IDC wiring resistance: 1500 Ohms.
Maximum IDC Voltage: 11 Volts.
Maximum IDC Current: 450 pA.
EOL resistance: 47K Ohms.
Temperature range: 32°F to 120°F (0°C to 49°C).
Humidity range: 10% to 93% noncondensing.
Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x
0.65" (1.651 cm) deep.
Wire length: 6" (15.24 cm) minimum.
MMF-302(A) Interface Module
• Supports compatible two -wire smoke detectors.
• Supervises IDC wiring and connection of external power
source.
• High noise (EMF/RFI) immunity.
• SEMS screws with clamping plates for ease of wiring.
• Direct -dial entry entry of address: 01 — 159 on MS -9600
series panels, 01 — 99 on other compatible systems.
• LED flashes during normal operation.
• LED latches steady to indicate alarm on command from
control panel.
The MMF-302(A) Interface Module is intended for use in intelli-
gent, addressable systems, where the individual address of
each module is selected using built-in rotary switches. This
module allows intelligent panels to interface and monitor two -
wire conventional smoke detectors. It transmits the status
(normal, open, or alarm) of one full zone of conventional
detectors back to the control panel. All two -wire detectors
being monitored must be UL compatible with the module. The
MMF-302(A) can be used to replace M302(A) modules in
existing systems.
MMF-302 (A) APPLICATIONS
Use the MMF-302(A) to monitor a zone of two -wire smoke
detectors. The monitored circuit may be wired as an NFPA
Style B (Class B) or Style D (Class A) Initiating Device Circuit.
A 3.9 K Ohm End -of -Line Resistor (provided) terminates the
end of the Style B or D (lass B or A) circuit (maximum IDC
loop resistance is 25 Ohms). Install ELR across terminals 8
and 9 for Style D application.
MMF-302(A) OPERATION
Each MMF-302(A) uses one of the available module
addresses on an SLC loop. It responds to regular polls from
the control panel and reports its type and the status (open/nor-
mal/short) of its Initiating Device Circuit (IDC). A flashing LED
indicates that the module is in communication with the control
panel. The LED latches steady on alarm (subject to current
limitations on the loop).
MMF-302(A) SPECIFICATIONS
Nominal operating voltage: 15 to 32 VDC.
Maximum current draw: 5.1 mA (LED on).
Maximum IDC wiring resistance: 25 Ohms.
Average operating current: 270 pA, 1 communication and 1
LED flash every 5 seconds, 3.9k ect.
EOL resistance: 3.9K Ohms.
Extemal supply voltage (between Terminals T10 and T11):
• DC voltage: 24 volts power limited.
• Ripple voltage: 0.1 Vrms maximum.
• Current: 90 mA per module maxinum.
Temperature range: 32°F to 120°F (0"C to 49°C).
Humidity range: 10% to 93% noncondensing.
Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x
1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x
2.125" (5.398 cm) deep box.
MDF -300(A) Dual Monitor Module
The MDF -300(A) Dual Monitor Module is intended for use in
intelligent, two -wire systems. It provides two independent two -
wire initiating device circuits (IDCs) at two separate, consecutive
addresses. It is capable of monitoring normally open contact fire
alarm and supervisory devices. The module has a single panel -
controlled LED.
Page 2 of 4 — DF -52121:E • 07/30/2015
NOTE: The MDF -300(A) provides two Style B (Class B) IDC cir-
cuits ONLY. Style D (Class A) IDC circuits are NOT supported in
any application.
MDF -300(A) SPECIFICATIONS
Normal operating voltage range: 15 to 32 VDC.
Maximum current draw: 6.4 mA (LED on).
Average operating current: 750 pA (LED flashing).
Maximum IDC wiring resistance: 1,500 Ohms.
Maximum IDC Voltage: 11 Volts.
Maximum IDC Current: 240 pA
EOL resistance: 47K Ohms.
Temperature range: 32° to 120°F (0° to 49°C).
Humidity range: 10% to 93% (non -condensing).
Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x
1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x
2.125" (5.398 cm) deep box.
MDF -300(A) AUTOMATIC ADDRESSING
The MDF -300(A) automatically assigns itself to two address-
able points, starting with the original address. For example, if
the MDF -300(A) is set to address "26', then it will automati-
cally assign itself to addresses "26" and "27".
NOTE: "Ones" addresses on the MDF -300(A) are 0, 2, 4, 6, or 8
only. Terminals 6 and 7 use the first address, and terminals 8 and
9 use the second address.
CAUTION:
Avoid duplicating addresses on the system.
Installation
MMF-300(A), MMF-302(A), and MDF -300(A) modules mount
directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm)
deep, electrical box. They may also be mounted to the
SMB500 surface -mount box. Mounting hardware and installa-
tion instructions are provided with each module. All wiring
must conform to applicable local codes, ordinances, and regu-
lations. These modules are intended for power -limited wiring
only.
The MMF-301(A) module is intended to be wired and mounted
without rigid connections inside a standard electrical box. All
wiring must conform to applicable local codes, ordinances,
and regulations.
Agency Listings and Approvals
In some cases, certain modules may not be listed by certain
approval agencies, or listing may be in process. Consult fac-
tory for latest listing status.
• UL: S2424.
• ULC: S2424.
• FM Approved.
• CSFM: 7300-0075:0185.
• MEA: 72-01-E.
Product Line Information
NOTE: A" suffix indicates ULC -listed model.
MMF-300(A): Monitor module.
MMF-301(A): Monitor module, miniature.
MMF-302(A): Monitor module, two -wire detectors.
MDF -300(A): Monitor module, dual, two independent Class B
circuits.
SMB500: Optional surface -mount backbox.
NOTE: See installation instructions and refer to the SLC Wiring
Manual, PN 51309.
Architects'/Engineers' Specifications
Specifications of these devices and all FireLite products are
available from FireLite.
DF -52121:E • 07/30/2015 — Page 3 of 4
Fire•Lite® Is a registered trademark and UteSpeedTM and FireWatchTM are
trademarks of Honeywell International Inc.
02015 by Honeywell International Inc. All Eights reserved. Unauthorized use
of this document is strictly prohibited.
ISO 9001
BURMA i MANIFACTIBIN6
QUALITY SYSTEMS
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.
www.firelite.com
Page 4 of 4 — DF -52121:E • 07/30/2015
SD355(A) Series
Addressable Photoelectric
Smoke Detectors
OF -52384:D • E-160
FIre•LlTe®ALarms
by Honeywell
Addressable Devices
General
The SD355(A), SD355T(A), and SD355R(A) addressable,
low -profile plug-in photoelectric detectors use a state-of-the-
art photoelectric sensing chamber with communications to
provide open area protection and are used exclusively with
Fire•Lite's Addressable Fire Alarm Control Panels (FACPs).
The SD355T(A) adds thermal sensors that will alarm at a fixed
temperature of 135°F (57°C). Since these detectors are
addressable, they will help emergency personnel quickly
locate a fire during its early stages, potentially saving precious
rescue time while also reducing property damage. Two LEDs
on each sensor light to provide a local, visible sensor indica-
tion. Remote LED annunciator capability is available as an
optional accessory, PN RA100Z(A). The SD355R(A) is a
remote test capable detector for use with D355PL(A) or
DNR(A)/DNRW duct smoke detector housings.
Features
SLC LOOP
• Two -wire loop connection.
• Unit uses base for wiring.
ADDRESSING
• Addressable by device.
• Rotary, decimal addressing: 01 – 99 with MS-9200UD(LS),
and 01 – 159 with MS-9600UD(LS).
ARCHITECTURE
• Unique single -source, dual-chamber design to respond
quickly and dependably to a broad range of fires.
• Sleek, low -profile design.
• Integral communications and built-in type identification.
• Built-in tamper-resistant feature.
• Removable cover and insect -resistant screen for simple
field cleaning.
OPERATION
• Withstands air velocities up to 4,000 feet -per -minute (20 m/
sec.) without triggering a false alarm.
• Factory preset at 1.5% nominal sensitivity for panel alarm
threshold level.
• Visible LED "blinks" when the unit is addressed (communi-
cating with the fire panel) and latches on in alarm.
MECHANICALS
• Sealed against back pressure.
• Direct surface mounting or electrical box mounting.
• Mounts to: single -gang box, 3.5" (8.89 cm) or 4.0" (10.16
cm) octagonal box, or 4.0" (10.16 cm) square electrical box
(using a plaster ring — included).
OTHER SYSTEM FEATURES
• Fully coated circuit boards and superior RF/transient pro-
tection.
• 94 -VO plastic flammability rating.
• Low standby current.
SD355(A) in B210LP(A) Base
OPTIONS
• Remote LED output connection, PN RA100Z(A).
Applications
Use photoelectric detectors in life -safety applications to pro-
vide a broad range of fire -sensing capability, especially where
smoldering fires are anticipated. Ionization detectors are often
better than photoelectric detectors at sensing fast, flaming
fires.
Construction
These detectors are constructed of off-white fire resistant plas-
tic. SD355(A) series plug-in, low -profile smoke detectors are
designed to commercial standards and offer an attractive
appearance.
Installation
SD355(A) series plug-in detectors use a detachable mounting
base to simplify installation, service and maintenance.
Mount base (all base types) on an electrical backbox which is
at least 1.5" (3.81 cm) deep. For a chart of compatible junction
boxes, see DF -60059.
NOTE: Because of the inherent supervision provided by the SLC
loop, end -of -line resistors are not required. Wiring 'T -taps" or
branches are permitted for Style 4 (Class B) wiring. SD355R(A)
mounts in a D355PL(A) or DNR(A)/DNRW duct detector housing.
Operation
Each SD355(A) series detector uses one of 99 possible
addresses on the MS-9200UD(LS) and up to 318 (159 on
each loop) on the MS-9600UD(LS) Signaling Line Circuit
(SLC). It responds to regular polls from the system and reports
its type and status.
The addressable photoelectric sensor in the SD355(A) series
has a unique unipolar chamber that responds quickly and uni-
formly to a broad range of smoke conditions. It can withstand
wind gusts up to 4,000 feet -per -minute (20 m/sec.) without
sending an alarm level signal. Because of its unipolar cham-
ber, the SD355(A) series is approximately two times more
responsive than most photoelectric sensors. This makes it a
more stable detector.
DF -52384:D • 2/11/2015 — Page 1 of 2
•
Detector Sensitivity Test
Each detector can have its sensitivity tested (required per
NFPA 72, Chapter 14 on Inspection, Testing and Maintenance)
when installed/connected to a MS-92000D(LS) or MS-
96000D(LS) addressable fire alarm control panel. The results
of the sensitivity test can be printed off the MS-92000D(LS) or
MS-96000D(LS) for record keeping.
Specification
Voltage range: 15 — 32 VDC (peak).
Standby current: 300 pA 0 24 VDC.
LED current: 6.5 mA 0 24 VDC (latched "ON").
Air velocity: 4,000 ft./min. (20 m/sec.) maximum.
Size: 2.1" (5.33 cm) high; base determines diameter.
— B210LP(A): 6.1' (15.5 cm) diameter.
— B501(A): 4.1" (10.4 cm) diameter.
— B200SR(A): 6.875" (17.46 cm) diameter.
— B224RB(A): 6.2" (15.748 cm) diameter.
Weight: 3.6 oz. (102 g).
Operating temperature range: for SD355(A): 0°C to 49°C
(32°F to 120°F); for SD355T(A): 0°C to 38°C (32°F to 100°F).
SD355R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F
to 158°F).
Temperature: 0°C — 49°C (32°F — 120°F).
Relative humidity: 10% — 93%, non -condensing.
Listings
Listings and approvals below apply to the SD355(A),
SD355T(A), and SD355RT(A) detectors. In some cases, cer-
tain modules may not be listed by certain approval agencies,
or listing may be in process. Consult factory for latest listing
status.
• UL Listed: S1059.
• ULC Listed: S1059.
• CSFM: 7272-0075:0194.
• MEA: 243-02-E.
• FM approved.
Product Line Information
NOTE: A" suffix indicates ULC Listed model.
SD355: Addressable photoelectric detector; B210LP base
included.
SD355A: Sames as SD355 with ULC Listing; B210LPA base
included.
SD355T: Same as SD355 but with thermal element; B210LP
base included.
SD355TA: Same as SD355T with ULC Listing; B210LPA base
included.
SD355R: Remote test capable addressable photoelectric
detector for use with a D355PL(A) or DNRA/DNRW duct
detector housing; B210LP base included.
SD355RA: Same as SD355R with ULC Listing for use with a
D355PLA or DNRA duct detector housing; B210LPA base
included.
INTELLIGENT BASES
NOTE: W suffix indicates ULC Listed model.
NOTE: The detector's plug-in base can be changed off for special
applications. For details about intelligent bases and their mount-
ing, see DF -60059.
B210LP(A): Plug-in detector base (included); standard U.S.
flanged low -profile mounting base.
B210LPBP: Bulk pack of B210LP; package contains 10.
B501(A): Standard European flangeless mounting base.
B501BP: Bulk pack of B501; package contains 10.
B200SR(A): Intelligent sounder base capable of producing
sound output with ANSI Temporal 3 or continuous tone.
Replaces 8501 BH series bases in retrofit applications.
B224RB(A): Plug-in System Sensor relay base. Screw termi-
nals: up to 14 AWG (2.0 mm2). Relay type: Form -C. Rating: 2.0
A 0 30 VDC resistive; 0.3 A 0 110 VDC inductive; 1.0 A 0
30 VDC inductive.
B224BI(A): Plug-in System Sensor Isolator detector base.
Maximum 25 devices between isolator bases (see DF -52389).
ACCESSORIES
F110: Retrofit flange to convert B210LP(A) to match the
B350LP(A) profile, or to convert older high-profile bases to
low -profile.
F110BP: Bulk pack of F110; package contains 15.
F210: Replacement flange for B210LP(A) base.
RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to
a U.S. single -gang electrical box. For use with B501(A) and
B210LP(A) bases only.
SMB600: Surface mounting kit
M02-04-00:Test magnet.
M02-09-00: Test magnet with telescoping handle.
XR2B: Detector removal tool. Allows installation and/or
removal of detector heads from bases in high ceiling applica-
tions.
XP -4: Extension pole for XR2B. Comes in three 5 -foot
(1.524 m) sections.
T55-127-010: Detector removal tool without pole.
BCK-200B: Black detector covers for use with SD355(A) only;
box of 10.
WCK-200B: White detector covers for use with SD355(A)
only; box of 10.
FlreLlte® Alarms is a registered trademark of Honeywell International Inc.
02015 by Honeywell Intemational Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
ISO 9001
BiINEME 1; MMIFACiluNS
QUALITY SYSTEMS
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.
www.firelite.com
Page 2 of 2 — DF -52384:D • 2/11/2015
ACCEPTED
D Without Comments
As Noted in Red
o Per The Attached Letter
These plans have beer eviewed by The Tukwila Fire
Prevention Bureau for e^nformance with current City
standards. Acceotanco :subject to errors and
or nissions which no i -sot violations of adopted
s'<andards and oiY.:ir:,cor.7.:-. :r''if, responsibility for the
adequacy of design .:r 'fai: ri: with the Jesigne+.
Additions, dele osis , . 4doris to Mese drawings ante-
this dist ;'!i9 void trbis: ..,;,:e �.�tz-3, , 7,4.0d will require a
resubrrsictal 7` rw,,;rrr T; a,,a ., r,, :'.rtseouer' : pproval
Final accepra ..e. -..
The Tukwila
;r anu inspection by
Date: 5 '"f -f 7 by:
NOTICE
A completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the ,:nsr.ector prior to
commencement of Acceptance
Testing ,{)f ;y Fire Alarm
and Oei:ection Systems.
Failure cif test will result
in a Re -inspection Fee and
termination of the testing
e4fdk .Ni "ch :"1"v ttVir-c iv /14vt- -s Owh atAA►AS
a +.4 r�.av4 a s 5./c.L• 4,C ,4-'r l S 44v0l
E104% -e. hAhak cIQwr ;Cww f4
TUKWItA FIRE DEPARTMENT
P;ease
si 2O`;-575-4407 and
4yArc this s Fir Permit No.
/7 =-1(es
,id exact address for shut
frown or restoration approval.
EX. WORKSHOP
IGHT ASSEMBLY)
Necl:
2
EX. wQRKSHDP
BATHROOM
STORAGE AREA
(UNHEA D)
EOL
DRAWN BY D. LEE
DATE' 8-8-94
CHECKED
DATE
SCALE' 1/81=1'-0°
NIAIN FLER ALAN
SCAL
1/8"=1'-0
APPROVED
DATE
D. LEE
CRUSON
OSWALT
41351111011111.
/1
SECURITY SYSTEMS
1916 BOREN AVE.
SEATTLE, WA. 98101
(206) 624-3103
FAX' 623-3269
1
-71
Cup ENT R___--
UNIT
; ti ----7S
7 r .
DEN
TH
KITCHEN
;: FIRST r._:LR
PRIVATE STAIRWAY
S
DECK
LIVING
STCRA5E AREA
(UNHEATED)
...//
S-ALfl 1/8" =1" -
PROJECT NAME
OXY CIRCL
SHEET TITLE
FIRE ALARM WIRING
All fire alarm,, wirin` shall ti_ installed in accordance with NEC as administered by L & I and
the following'
1. All alarm wiring shall L S T ED for alarm service,
2, Fire alarm riser tirir) r :;ening from floor to floor shall be LISTED Riser Cable (CL2R, or
_P, R:
3, T --taps on fire ,alarm
4, Looping of connections
5 Fire alarm wire sh(all
ming is not permitted.
to terminals on continuous runs of' fire alarm wire is not permitted,
:got spliced In any plenum or duct space except where contained in
an approved fire-nesi_t'i : = and low -smoke producing electrical box.
6. Wiring penetra th 1--,-ated =walls or ceilings shall be installs in non-combustible
penetrating elements pening_ sealed in an approved. manner.
SMLKE DETECTORS
Smoke detectors st1: V,
36 inches away Fee.,.,
exceeds the listing
Not in close proe:Lni
3. Specific locations
and such that. nc
stalled in accordance with the following;
air handling system diffuser and not in any •area where airflow
device.
any fluorescent light fixture,
in accordance with listed spacing requirements for the device
a room or area is unprotected.
Final approval and of the fire alarm system complying with installation design
requires testing of!
1. Operation of all c'e`.'i:_'es, appliances, and equipment including but not limited to, manual
devices, HVAC equipment, 1e ✓ator recall, auxiliary devices, and alarm signal service, per
1991 Uniform Fire Coe'e, :f'r7andarc 14-3, A copy of' the Acceptance Test Report will be filled
cut utilizing the C.on 'ic)E ce Test ,Report form, and will be supplied to the Fire Inspector upon
completion of the test,
The perrnitee shall 7r o written certification to the Fire inspector that the system has
been installed in accorei ee with the approved plans and specifications.
INDEFFENDENT SUPFORT : FVICES
system devices shall be mounted independently of their attachment to
circuit conductors. .,,proved electrical boxes LISTED for the area of application,
HDRN/S T ROB= MEUi < T it:._
All horn/strobe „ ...-r1 devices shall
or 6 inches below the e:. n;;, whichever is
be installed not less than 80 inches above floor levet,
tower.
NOTE! HEIGHT OF ! 22 ;':: LEE DEVICES IS MEASURED FREM THE
FLOOR TO THE BrTTC "r HE DEVICE - NOT TO THE TOP,
MANUAL PULL STA i ILIN i _7 _ a i _' N,.j
All manual pull stations shall be mounted in accordance with the following'
1. 54 inches above j -e! r icor where 'parallel approach' is established and- maintained, ori
2. 48 inches above th ; =icor where 'parallel approach' cannot be established or maintained.
NPTEs Parallel appreaci. 's a 60 inch clear space parallel and adJacent to a pull station,
Per N TA 7=' 3--2.2, an. ;al _,ll box height Is measured to the
BUTT EM of the
ACCE!TED
WITHOUT COMMENTS.
lad AS NOTED IN RED
0 PER THE ATTACHED LETTER
The drawings affixed hereto have been
reviewed and accepted by the City of
Tukwila Fire Dept. Aiditions, deletions
or revisions to these drawings after this
date will void this acceptan:a and will
require a resubmittal of revised drawings.
Final acceptance is subject to field -
inspection by a representative of this
department
DATE: S 2r- V BY: ' /fl
CITY OF TUKWILA
575 4407
0
L E J
EI
TUKWILA FiRE DEPARTMEI
Please call: 575.4407
and give this job
No. 9Y--
and
yand exact address for shut
down or restoration approval;
\ID
CII
ACU
SNC<E DETECTOR
EAT DETECTOR
FIXES TEMP, HEAT
MANUAL PULL
HUR\/STRC3E
HORN
CONTREL UNIT
DET
IiR`VISIONS
NE. DATE
8-10-94
43000
DESCRIPTION
ADDED DEVICES (FIRE DEPT) D, LEE
it