Loading...
HomeMy WebLinkAboutPP - 3433 S 120TH PL - INTERGATE EAST BUILDING 4 - PERMITS AND PLANS3433 S 120TH PL ASSOCIATED PERMITS 09-F-003 09-F-106 09-F-158 10-F-112 12-F-249 13-F-101 19-F-244 08-S-222 10-S-077 13-S-063 13-S-180 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** ing Co. Assessor's Tax No.: Site Address: 3'/.33 S I,ZOT'1 1" i Suite Number: Floor: Tenant Name: SA 3 Ey Property Owner's Name: $ P36/ Mailing Address: 1 New Tenant? ❑ - Yes,- No City CONTACT PERSON -if there are questions about the submittal. Name: Wlt✓R EV65 State Zip Day Telephone: Zs3 2-4 5'd o Company Name: C..a e pressi Sis-fir, Mailing Address: 3511 a.o` 41 S "A"I' 4-1 'Ziacmek vvf1 (48 'Or City State Zip E-mail Address: Niriik LSJeP^msste.J. Caw\ Fax Number: 9.5-.311-6330b Contractor's City of Tukwila NICET III number: I 1 101IL Business License number: L Total number of new/relocated devices or sprinkler heads: S. VES b/e \15. P -No Intr5- Valuation of Project (contractor's bid price): $ 3% Nu,. C-) Scope of Work (please provide detailed information): Late, S i��t Rif Sc,t r p (� Swt.— tal PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature:rDate: 1419 t Print Name: CAA CAI —L,'"' Day Telephone: A5gele, 3'3.06Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 1 O26CU Site Address: 3ASO• \ G.Dit1 Suite Number: Floor: Tenant Name:1 Property Owner's Name: Mailing Address: City State Zip New Tenant? ❑ - Yes 'No CONTACT PERSON -if there are questions about the submittal. Name: 1•41/..);211 Day Telephone:.�S3 _ o&(, J3 O J Company Name: s..60-s. c/o-. &(-1 Mailing Address: LA� �� i�+AC . ► Q l 1' p` �r�,.% \L C -O r L s �H V City _ State Zip .% r E-mail Address: IN \A eSVMMQR-�`ol tr. . C C) �, Fax Number: e9S-1 -1 C17—to3 c� Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 1 t OO C7 Scope of Work (please provide detailed information): ta‘V.O,L.. C *_ V_.,>0( 5Z \ to"-ZC W t.D IAA-) Fitav wc_k tU C -'-c• $Ooz, }' ?c._ r\e, PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ^OWNER OR AUTHORIZED AGENT: 1 ' Signature: V v'�Date: C3 I t 1 "► Print Name: +A, %11.3424$ Day S -K\J Day Telephone: ° 2.iv - oco Plan Permit App.doc 1/2/13 TFD FP Form 8 Plane SITE LOCATION Site Address: Tenant Name: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SLIS S Ito %0„ Tit X Property Owner's Name: S AO Mailing Address: `f 3 3 5. 12-6111 lel CONTACT PERSON -if there are questions about the submittal. Name: AO/4w‘ C �bx / ZL ?RE& Air "/ Company Name: King Co. Assessor's Tax No.: 107-3O4 1O81 Suite Number: Floor: New Tenant? ❑ - Yes I,- No �vkuJs�A l � qi / 63 City State Zip Day Telephone: 56k) $'r 1 trit ' Mailing Address: Po I5 o X 5' i C/OXFiLt PREt *?iJcco�1City E-mail Address: 1-,o0� Total number of new/relocated devices or sprinkler heads: o Pr exam -o lA 7.M.6 State Zipp Fax Number: 1 (pO 0V ZZlv2 Valuation of Project (contractor's bid price): $ /ZOOO i o z' Scope of Work (please provide detailed information): ea / C-DGArEi /74), AL.e. zi_AA ka.1-J___ , x frypeu ..;,,3_, PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTHOAGENT: Signature: s -r Date �4U/ f3' Print Name: ,4 C> L Day Telephone: 3&C) 644 08.s --- Plan l8,s--- Plan Permit App.doc 1/2/13 TFD FP Form 8 401tvir44 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 102- 36 4 - 1681 8' li Site Address: 1 S 3 S t ZO ' Q� 1 O \4v-) lL t Property Owner's Name:} La`(L-p S4'Y- S 1 Zai" Tenant Name: Mailing Address: Suite Number: Floor: New Tenant? ❑ - Yes '`- No CONTACT/PERSON-if there are questions about the submittal. Name: A- 0, vL Company Name: Mailing Mailing Address: 17d 5 O X 6 uk yu: 924191, City State Zip Day Telephone (ex) is ter crRc-c iKo Vi `1S% State Z.i.p Fax Number:'�(42c.D C -- E-mail Address: WZ> @<T20'N n2L F'e-f ,A11: Total number of new/relocated devices or sprinkler heads: City 6-0 Valuation of Project (contractor's bid price): $ 2 3O D' l / L cJ'il Scope of Work (please provide detailed information):Se- >✓ X t {j °'71°/-4-ZA dA7141,L4" PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR THORI EDA Signature: Date:[ (iii4 (3 Print Name: ! v © — G Day Telephone:'S%O 8 -7-/ /4) 8 5— Plan Permit App.doc 1/2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assess Site Address: 3 C -I 33 S 1 ZOO-`` 2 L (ac F Suit Tenant Name: _- NT 2Co AT F E S -T Property Owner's Name: S F: S p y CoRPO RA'T-to Mailing Address: 3 `{33 S l 2O1-" I c E LI\ City New Tenant? ❑ - Yes IZ - No CONTACT PERSON -if there are questions about the submittal. Name: -TS-kAc Fa MS Li q6h & State Zip Day Telephone: Z O(o - 31 I - Co 7.0 Co Company Name: Gvcacao 1 A1\ SECvczvTN Mailing Address: 17 4 3 F `2S -r A V F SoU-r H S._Fa-Tf Lf_ w(\ q 13 LII City State Zip E-mail Address: i-ar3arrsSQti, 4vre-k.C.612AJSewS-Al • CO '0,. Fax Number: 2.c."6 - 4 l~- 99ZSc- Valuation of Project (contractor's bid price): $ ROO Scope of Work (please provide detailed information): 1 NS i AES `SAS) 1G -r Q\s Iv 5 - -7T t f (Z E 1ST11VC. l-Ac� (F�fU1-0 N�_ 1 Zoo0 c-0,(--) PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Date: It Iz-c-t I2.O12 -11Z_ (\c (,D ✓V\ S Day Telephone: -7_0(Q — 33I - (0Z0CP Plan Permit App.doc 5/14/10 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: MS-Tuk2 3433 120th PI. S. Permit No.: 08-S222 Date: May 22, 2008 Reviewer: Steve Kohler Fire Inspector/Plan Review (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. All references are NFPA 13, 2007 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: TELEX 3433 S 120th PI Permit No.: 13-S-063 Date: March 14, 2013 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 '/ inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. wf • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: TELX 3433 S 120th PI Permit No.: 13-S-180 Date: August 6, 2013 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'A inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • Maintain a 4 ft. clear space around the sprinkler riser for emergency access. • An electrically supervised post indicating valve (PIV) is required. • PIV shall have the building number served by the PIV stenciled vertically in 3 - inch high white numbers on a "safety red" background, facing the direction of vehicular access. • The height of the fire department connection (FDC) shall be 36 to 48 inches above grade. • The FDC shall have a downward angle bend of 30 degrees with a 5 -inch Storz connection and a Knox locking Storz cap. • Install listed water shields on in -rack sprinklers. • Installation of all electrical pre -action system components requires a separate fire alarm permit and an electrical permit. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. Ccovri ht (c) due al USA, 2004 "SKIFF" 3.4 Project: TES COLO 5 AND 6 e: C:\Sniff\?rojects\1309\CO 5 'ORTH.SCIF Caleglation Date/Time: Apr 16, 2013, 1:26:54 PM Customer And Project Report ---- Distributor -- Name: SUPPRESSION SYSTEMS INC. Address: 4417 PACIFIC HIGHWAY ST : TACOMA, WA 98424 Phone: 253-926-3300 ---- Customer ---- Kane: TELX Address: 3433 SCSTH 120TH PLACE : BUILDING #4 : TUKWILA, WA 98168 F e e: Contact: Title: ---- Project ---- 9 elect: TELX COLO 5 AND 6 Designer: NIS M REEVES Number: 1309 Account: Location: COLO 5 NORTH nese.: RETURN AIR SAMPLING FOR 4 CRAH UNITS. Page: C ytighL (c) Kidde-r nwal OSA, 2004 "SNIFF" 3,4 P oect: TELX COLO 5 AND 6 File Name: C:\Sniff\Projects\1309\COLO 5 NORTH.SNF Caiculatioo Date/Time: Apr 1E, 2013, 1:26:54 PM Protected Arand Detector Report Protected Area Number : 1 Name : COLO 5 NORTH Avg Te pelatule : 70 Static Pressure Differential : 0 Air velocity Index : Above 10 and eels 20 Detector Name: AnaLASER Mods:a= System without an E:utriator, without an Exhaust Port. Elevation: 0 feet (at sea level) Page: 2 Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND 6 File Name: C:\Sniff\Projects\1309\COLO 5 NORTH.SNF Calculation Date/Time: Apr 18, 2013, 1:26:54 PM Parts List Report Detector Name: AnaLASER Modular System without an Elutriator, without an Exhaust Port. Quantity Length Diameter Type Pipe: 4 0.58 ft 3/4 in PVC 4 1.58 ft 3/4 in PVC 4 6.16 ft 3/4 in PVC 8 9.83 ft 3/4 in PVC 3 14.66 ft 3/4 in PVC Total: 155.90 ft 1 8.00 fti. in PVC 1 21.33 ft 1 in PVC Total: 29.33 ft 90° Elbows: 9 3/4 in PVC 1 lin PVC Tees: 6 3/4 in PVC 1 3/4 in x 1 in x 3/4 in PVC End Caps: 8 3/4 in PVC Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 1.4 Project: TELX COLO 5 ANEY6 File Name: C:\Sniff\Projects\1309\COLO 5 NORTH.SNF Calculation Date/Time: Apr 18, 2013, 1:26:54 PM Main Calculations Results Calculated Transport Time = 34.8 Maximum Allowable Transport Time = 120.0 Flow = 0.03572464 CF/Sec Seg-1Samplel Holel Pipe' PipelBran-I Hole 1 - Ext.lExt.1 Suction 1 % of1 Relat. mentlHole 1DiameterlDiameter1 Len.1ches 1 Dist.1DiameteriLen.1Pressure1Total1 Sensi- 1 1 1 1 1 1 1 1 . 1 1 Flowl tivity 1 1 inches 1 inches 1 feet! 1 feet 1 IfeetlIn Water' 1%ob/ft 1 3/4 in 0.0 1 2 1 in 8.0 1 3 1 in 21.3 2 4 3/4 in 6.2 2 5 3/4 in 1.6 1 6 3/4 in 9.8 0 6.1 1/16 in 6.2 1/16 in 6.3 1/16 in 6.4 1/16 in 6.5 1/16 in 7 3/4 in 0.6 1 8 3/4 in 9.8 0 8.1 1/16 in 8.2 1/16 in 8.3 1/16 in 8.4 1/16 in 8.5 1/16 in 9 3/4 in 14.7 2 10 3/4 in 6.2 2 11 3/4 in 1.6 1 12 3/4 in 9.8 0 12.1 5/64 in 12.2 5/64 in 12.3 5/64 in 12.4 5/64 in 12.5 5/64 in 13 3/4 in 0.6 1 14 3/4 in 9.8 0 14.1 5/64 in 14.2 5/64 in 14.3 5/64 in 14.4 5/64 in 14.5 5/64 in 15 3/4 in 14.7 2 16 3/4 in 6.2 2 17 3/4 in 1.6 1 18 3/4 in 9.8 0 18.1 3/32 in 18.2 3/32 in 18.3 3/32 in 18.4 3/32 in 18.5 3/32 in 19 3/4 in 0.6 1 20 3/4 in 9.8 0 20.1 3/32 in 20.2 3/32 in 20.3 3/32 in Page: 4 0.5 3/4 in 0.0 -0.427 2.12% .70657 2.5 3/4 in 0.0 -0.426 2.11% .70944 4.5 3/4 in 0.0 -0.425 2.11% .71009 6.5 3/4 in 0.0 -0.425 2,11% .71053 8.5 3/4 in 0.0 -0.424 2.11% .71075 0.5 3/4 in 0.0 -0.428 2.12% .70803 2.5 3/4 in 0.0 -0.427 2.12% .70890 4.:5 3/4 in 0.0 -0.426 2.11% .70955 6.5 3/4 in 0.0 -0.425 2.11% .70999 8.5 3/4 in 0.0 -0.425 2.11% .71021 0.5 3/4 in 0.0 -0.221 2.38% .63016 2.5 3/4 in 0.0 -0.220 2.37% .63165 4.5 3/4 in 0.0 -0.219 2.37% .63278 6.5 3/4 in 0.0 -0.219 2.37% .63354 8.5 3/4 in 0.0 -0.219 2.37% .63392 0.5 3/4 in 0.0 -0.222 2.38% .62923 2.5 3/4 in 0.0 -0.221 2.38% .63072 4.5 3/4 in 0.0 -0.220 2.37% .63184 6.5 3/4 in 0.0 -0.219 2.37% .63260 8.5 3/4 in 0.0 -0.219 2.37% .63298 0.5 3/4 in 0.0 -0.155 2.87% .52208 2.5 3/4 in 0.0 -0.154 2.86% .52385 4.5 3/4 in 0.0 -0.154 2.86% .52519 6.5 3/4 in 0.0 -0.153 2.85% .52609 8.5 3/4 in 0.0 -0.153 2.85% .52654 0.5 3/4 in 0.0 -0.156 2.88% .52099 2.5 3/4 in 0.0 -0.155 2.87% .52274 4.5 3/4 in 0.0 -0.154 2.86% .52407 20.4 3/32 in 20.5 3/32 in 21 3/4 in 14.7 1 22 3/4 in 6.2 2 23 3/4 in 1.6 1 24 3/4 in 9.8 0 24.1 3/32 in 24.2 3/32 in 24.3 3/32 in 24.4 3/32 in 24.5 3/32 in 25 3/4 in 0.6 1 26 3/4 in 9.8 0 26.1 3/32 in 26.2 3/32 in 26.3 3/32 in 26.4 3/32 in 26.3 3/32 in Page: 5 6.5 3/4 in 0.0 -0,154 2.86% .52497 8.5 3/4 in 0.0 -0.153 2.85% .52542 0.5 3/4 in 0.0 -0.134 2.66% .56319 2.5 3/4 in 0.0 -0.132 2.65% .56541 4.5 3/4 in 0.0 -0,132 2.65& .56709 6.5 3/4 in 0.0 -0.131 2.64% .56823 8.5 3/4 in 0.0 -0,131 2.64% .56880 0.5 3/4 in 0.0 -0.I34 2.67% .56182 2.5 3/4 in 0.0 -0.133 2,66% .56402 4.5 3/4 in 0.0 -0,132 2.65% .56569 6.5 3/4 in 0,0 -0.132 2.65% .56682 8.5 3/4 in 0.0 -0.132 2.64% .56739 SUCTION PRESSURE MEASUREMENTS_ HOLE CALCULATED MEASURED NUMBER SUCTION PRESS. SUCTION PRESS. Inches of Water Inches of Water 6.1 -0.427 6.2 -0.426 6.3 -0.425 6.4 -0.425 6.5 -0.424 8.1 -0.428 8.2 -0.427 8,3 -0.426 8.4 -0.425 8.5 -0.425 12.1 -0.221 12.2 -0.220 12.3 -0.219 12.4 -0.219 12.5 -0.219 14.1 -0.222 14.2 -0.221 14.3 -0.220 14.4 -0.219 14.5 -0.219 18.1 -0.155 18.2 -0.154 18.3 -0.154 18.4 -0.153 18.5 -0.153 20.1 -0.156 20.2 -0.155 20.3 -0.154 20.4 -0.154 Page: 6 20.5 -0.153 24.1 -0,134 24.2 -0.132 24.3 -0.132 24.4 -0,131 24.5 -0.131 26.1 -0.134 26.2 -0,133 26.3 -0.132 26.4 -0.232 26.5 -0.132 End of Report Page: 7 "SNIFF" 3.4 2opyright (c) Kidde-Fenwal USA, 2004 Isometric View #: 2 File Name: C:\Sniff\Projects\1309\COLO 5 NORTH.SNF 2alculation Date/Time: 4/18/13 1:26:54 PM Page: 8 Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND 6 File Name: C:\Sniff\Projects\1309\COLO 5 SOUTH.SNF Calculation Date/Time: Apr 18, 2013, 1:28:12 PM Customer And Project Report ---- Distributor -- Name: SUPPRESSION SYSTEMS INC. Address: 4417 PACIFIC HIGHWAY EAST : TACOMA, WA 98424 Phone: 253-926-3300 ---- Customer Name: TELX Address: 3433 SOUTH 120TH PLACE : BUILDING #4 : TUKWILA, WA 98168 • Phone: Contact: Title: ---- Project ---- Project: TELX COLO 5 AND 6 Designer: NINA M REEVES Number: 1309 Account: Location: COLO 5 SOUTH Desc.: RETURN AIR SAMPLING FOR 4 CRAH UNITS. Page: 1 Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND 6 File Name: C:\Sniff\Projects\1309\COLO 5 SOUTH.SNF Calculation Date/Time: pr:18, 2013, 1:26:12 PM Protected Area and Detector Report Protected Area Number : 1 Name : COLO 5 SOUTH Avg Temperature : 70 Static Pressure Differential : 0 Air Velocity Index : Above 10 and Below 20 Detector Name: AnaLASER Modular System without an Elutriator, without an Exhaust Port. Elevation: 0 feet (at sea level) Page: 2 Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND 6 File Name: C:\Sniff\Projects\1309\COLO 5 SOUTH.SNF Calculation Date/Time: Apr 18, 2013, 1:28:12 PM Parts List Raport Detector Name: AnaLASER Modular System without an Elutriator, without an Exhaust Port. Quantity Length Diameter Type Pipe: 4 0.58 ft 3/4 in PVC 4 1.58 ft 3/4 in PVC 4 6.16 ft 3/4 in PVC 8 9.83 ft 3/4 in PVC 3 14.66 ft 3/4 in PVC Total: 155.90 ft 1 8.00 ft 1 in PVC 1 8.16 ft 1 in PVC Total: 16.16 ft 900 Elbows: 9 3/4 in PVC 1 1 in PVC Tees: 6 3/4 in PVC 1 3/4 in x 1 in x 3/4 in PVC End Caps: 8 3/4 in PVC Page: 3 Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND.6 File Name: C:\Sniff\Projects\1309\COLO 5 SOUTH.SNF Calculation Date/Time: Apr 18, 2013, 1:28:12 PM Hain Calculations results Calculated Transport Time = 31.6 Maximum Allowable Transport Time = 120.0 Flow = 0.03755569 CF/Sec Seg-ISamplel Hole' Pipet PipelBran-1 Hole 1 Ext.IExt.1 Suction; % off Relat. mentlHole IDiameterlDiameterl Len.Iches 1 Dist. IDiametsrlLen.IPressurelTotall Sensi- 1 1 I I I I 1 1 1 1 Flowl tivity 1 1 inches 1 inches 1 feetl I feet 1 Ifeetlln water! I%ob/ft 1 3/4 in 0.0 1 2 1 in 8.0 1 3 1 in 8.2 2 4 3/4 in 6.2 2 5 3/4 in 1.6 1 6 3/4 in 9.8 0 6.1 1/16 in 6.2 1/16 in 6.3 1/16 in 6.4 1/16 in 6.5 1/16 in 7 3/4 in 0.6 1 8 3/4 in 9.8 0 8.1 1/16 in 8.2 1/16 in 8.3 1/16 in 8.4 1/16 in 8.5 1/16 in 9 3/4 in 14.7 2 10 3/4 in 6.2 2 11 3/4 in 1.6 1 12 3/4 in 9.8 0 12.1 5/64 in 12.2 5/64 in 12.3 5/64 in 12.4 5/64 in 12.5 5/64 in 13 3/4 in 0.6 1 14 3/4 in 9.8 0 14.1 5/64 in 14.2 5/64 in 14.3 5/64 in 14.4 5/64 in 14.5 5/64 in 15 3/4 in 14.7 2 16 3/4 in 6.2 2 17 3/4 in 1.6 1 18 3/4 in 9.8 0 18.1 3/32 in 18.2 3/32 in 18.3 3/32 in 16.4 3/32 in 18.5 3/32 in 19 3/4 in 0.6 1 20 3/4 in 9.8 0 20.1 3/32 in 20.2 3/32 in 20.3 3/32 in Page: 4 0.5 3/4 in 0.0 -0.462 2.17% .69060 2.5 3/4 in 0.0 -0.461 2.17% .69143 4.5 3/4 in 0.0 -0.460 2.17% .69205 6.5 3/4 in 0.0 -0.460 2.17%s .69247 8.5 3/4 in 0.0 -0.460 2.17% .69269 0.5 3/4 in 0.0 -0.463 2.17% .69009 2.5 3/4 in 0.0 -0.462 2.17% .69091 4.5 3/4 in 0.0 -0.461 2.17% .69153 6.5 3/4 in 0.0 -0.461 2.17% .69195 8.5 3/4 in 0.0 -0.460 2.17% .69217 0.5 3/4 in 0.0 -0.230 2.39% .62727 2.5 3/4 in 0.0 -0.228 2.39% .62878 4.5 3/4 in 0.0 -0.228 2.38% .62993 6.5 3/4 in 0.0 -0.227 2.38% .63071 8.5 3/4 in 0.0 -0.227 2.38% .63110 0.5 3/4 in 0.0 -0.230 2.39% .62633 2.5 3/4 in 0.0 -0.229 2.39% .62784 4.5 - 3/4 in 0.0 -0.228 2.38% .62898 6.5 3/4 in 0.0 -0.228 2.38% .62975 8.5 3/4 in 0.0 -0.227 2.38% .63014 0.5 3/4 in 0.0 -0.157 2.84% .52743 2.5 3/4 in 0.0 -0.155 2.83% .52930 4.5 3/4 in 0.0 -0.155 2.83% .53072 6.5 3/4 in 0.0 -0.154 2.82% .53168 8.5 3/4 in 0.0 -0.154 2.82% .53217 05 3/4 in 0.0 -0.157 2.85% .52627 2.5 3/4 in 0.0 -0.156 2.84% .52813 4.5 3/4 in 0.0 -0.155 2.83% .52954 20.4 3/32 in 20-5 3/32 in 21 3/4 in 14.7 1 22 3/4 in 6'2 2 23 3/4 in 1.6 1 24 3/4 in 9.8 0 24.1 3/32 in 24.2 3/32 in 24.3 3/32 in 24.4 3/32 in 24.5 3/32 in 25 3/4 in 0.6 1 26 3/4 in 9.8 0 26.1 3/32 in 26.2 3/32 in 26.3 3/32 in 26.4 3/32 in 26.5 3/32 in Page: 5 6.5 3/4 in 0.0 -0.155 2.83% .53050 8.5 3/4 in 0.0 -0.154 2.82% .53098 0.5 3/4 in 0.0 -0'134 2.63% '57085 2.5 3/4 in 0.0 -0,133 2.62% .57322 4.5 3/4 in 0.0 -0.132 2.61% ,57503 6.5 3/4 in 0.0 -0.131 2.60% .57625 8.5 3/4 in 0.0 -0,131 2.60% .57688 0.5 3/4 in 0.0 -0.134 2.63% .56938 2.5 3/4 in 0.0 -0.133 2.62% .57174 4.5 3/4 in 0.0 -0.132 2.62& .57353 6.5 3/4 in 0.0 -0.132 2.61% .57475 8.5 3/4 in 0.0 -0.132 2.61% .57537 SUCTION PRESSURE MEASUREMENTS HOLE CALCULATED MEASURED NUMBER SUCTION PRESS. SUCTION PRESS. Inches of Water Inches of Water 6.1 -0.462 6.2 -0.461 6.3 -0.460 6.4 -0.460 6.5 -0.460 8.1 -0.463 8.2 -0.462 8.3 -0.461 8.4 -0.461 8.5 -0.460 12.1 -0.230 12.2 -0.228 12.3 -0.228 12.4 -0.227 12.5 -0.227 14.1 -0.230 14.2 -0.229 14.3 -0.228 14.4 -0.228 14.5 -0.227 18.1 -0.157 18.2 -0.155 18.3 -0.155 18.4 -0.154 18.5 -0.154 20.1 -0.157 20.2 -0.156 20.3 -0.155 20.4 -0.155 Page: 6 20.5 24.1 - 0.154 -0.134 24.2 -0.133 24.3 - 0.132 24.4 -0.131 24.5 - 0.131 26.1 -0.I34 26.2 26.3 26.4 26.5 -0.133 -0.132 - 0,l32 End of Report Page: 7 "SNIFF" 3.4 Copyright (c) Kidde-Fenwal USA, 2004 Isometric View #: 2 File Name: C:\Sniff\Projects\1309\COLO 5 SOUTH.SNF Calculation Date/Time: 4/18/13 1:28:12 PM Page: 8 w AnaLASER M at i -System Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND 6 File Name: C:\Sniff\Projects\1309\COLO 6 NORTH.SNF Calculation Date/Time: Apr 18, 2013, 1:29:30 PM Customer And Project Report ---- Distributor ---- Name: SUPPRESSION SYSTEMS INC. Address: 4417 PACIFIC HIGHWAY EAST : TACOMA, WA 98424 Phone: 253-926-3300 Customer ---- Name: TELX Address: 3433 SOUTH 120TH PLACE : BUILDING #4 : TUKWILA, WA 98168 Phone: Contact: Title: ---- Project ---- Project: TELX COLO 5 AND 6 Designer: NINA M REEVES Number: 1309 Account: Location: COLO 6 NORTH Desc.: RETURN AIR SAMPLING FOR 3 CRAB UNITS. Page: 1 Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND 6 File Name: C:\Sniff\Projects\1309\COLO 6 NORTH.SNF Calculation Date/Time: Apr 18, 2013, 1:29:30 PM Protected Area and Detector Report Protected Area Number : 1 Name : COLO 6 NORTH Avg Temperature : 70 Static Pressure Differential : 0 Air Velocity Index : Above 10 and Below 20 Detector Name: AnaLASER Modular System without an Elutriator, without an Exhaust Port. Elevation: 0 feet (at sea level) Page: Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND 6 File Name: C:\Sniff\Projects\1309\COLO 6 NORTH.SNF Calculation Date/Time: Apr 18, 2013, 1:29:30 PM Parts List Report Detector Name: AnaLASER Modular System without an Elutriator, without an Exhaust Port. Quantity Length Diameter Type Pipe: 3 0.58 ft 3/4 in PVC 3 1.58 ft 3/4 in PVC 3 6.16 ft 3/4 in PVC 1 8.00 ft 3/4 in PVC 6 9.83 ft 3/4 in PVC 2 14.66 ft 3/4 in PVC 1 20.50 ft 3/4 in PVC Total: 141.76 ft 90° Elbows: 8 3/4 in PVC Tees: 5 3/4 in PVC End Caps: 6 3/4 in PVC Page: 3 Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND:6 File Name: C:\Sniff\Projects\1309\COLO 6 NORTH.SNF Calculation Date/Time: Apr 18, 2013, 1:29:30 PM Main Calculations Results Calculated Transport Time m 26.4 Maximum Allowable Transport Time = 120.0 Flew/ m 0.03176498 CF/Sec Seg-ISample1 Holel Pipet PipelBran-1 Hole I , Ext.1Ext.I SuctionI % ofI Relat. mentIHole IDiameterlDiameterl Len.Iches 1 Dist.IDiameterILen.IPressurelTotall Sensi- 1 1 1 feet 1 I Flow' tivity 1 1 inches 1 inches 1 feetl IfeetIIn WaterI I%ob/ft 1 3/4 in 0.0 1 2 3/4 in 8.0 1 3 3/4 in 20.5 1 2 4 3/4 in 6.2 2 5 3/4 in 1.6 1 6 3/4 in 9.8 0 6.1 5/64 in 0.5 3/4 in 0.0 -0.256 3.12% .48053 6.2 5/64 in 2.5 3/4 in 0.0 -0.255 3.11% .48170 6.3 5/64 in 4.5 3/4 in 0.0 -0.254 3.11% .48259 6.4 5/64 in 6.5 3/4 in 0.0 -0.253 3.10% .48320 6.5 5/64 in 8.5 3/4 in 0.0 -0.253 3.10% .48352 7 3/4 in 0.6 1 8 3/4 in 9.8 0 8.1 5/64 in 0.5 3/4 in 0.0 -0.257 3.13% .47981 8.2 5/64 in 2.5 3/4 in 0.0 -0.255 3.12% .48097 8.3 5/64 in 4.5 3/4 in 0.0 -0.255 3.11% .48185 8.4 5/64 in 6.5 3/4 in 0.0 -0.254 3.11% .48246 8.5 5/64 in 8.5 3/4 in 0.0 -0.254 3.11% .48278 9 3/4 in 14.7 2 10 3/4 in 6.2 2 11 3/4 in 1.6 1 12 3/4 in 9.8 0 12.1 3/32 in 0.5 3/4 in 0.0 -0.160 3.55% .42217 12.2 3/32 in 2.5 3/4 in 0.0 -0.159 3.54% .42381 12.3 3/32 in 4.5 3/4 in 0.0 -0.158 3.53% .42507 12.4 3/32 in 6.5 3/4 in 0.0 -0.157 3.52% .42594 12.5 3/32 in 8.5 3/4 in 0.0 -0.157 3.52% .42639 13 3/4 in 0.6 1 14 3/4 in 9.8 0 14.1 3/32 in 0.5 1 3/4 in 0.0 -0.161 3.56% .42115 14.2 3/32 in 2.5 3/4 in 0.0 -0.159 3.55% .42278 14.3 3/32 in 4.5 3/4 in 0.0 -0.159 3.54% .42403 14.4 3/32 in 6.5 3/4 in 0.0 -0.158 3.53% .42489 14.5 3/32 in 8.5 3/4 in 0.0 -0.158 3.53% .42534 15 3/4 in 14.7 1 16 3/4 in 6.2 2 17 3/4 in 1.6 1 18 3/4 in 9.8 0 18.1 3/32 in 0.5 3/4 in 0.0 -0.134 3.25% .46109 18.2 3/32 in 2.5 3/4 in 0.0 -0.133 3.24% .46323 18.3 3/32 in 4.5 3/4 in 0.0 -0.132 3.23% .46488 18.4 3/32 in 6.5 3/4 in 0.0 -0.131 3.22% .46601 18.5 7/64 in 8.5 3/4 in 0.0 -0.131 4.38% .34282 19 3/4 in 0.61 1 20 3/4 in 9.8 0 20.1 3/32 in 0.5 3/4 in 0.0 -0.135 3.26% .45977 20.2 3/32 in 2.5 3/4 in 0.0 -0.134 3.25% .46189 20.3 3/32 in 4.5 3/4 in 0.0 -0.133 3.24% .46352 Page: 4 20.4 20.5 3/32 in 3/32 in Page: 5 6.5 3/4 in 0_0 -0.132 3.23% .46465 '8.5 3/4 in 0.0 -0.132 3.22% .46524 SUCTION PRESSURE MEASUREMENTS HOLE CALCULATED MEASURED NUMBER SUCTION PRESS. SUCTION PRESS. Inches of Water Inches of Water 6.1 -0.256 6.2 -0.255 6.3 -0.254 6.4 -0.253 6.5 -0.253 8.1 -0.257 8.2 -0.255 8.3 -0.255 8.4 -0.254 8.5 -0,254 12.1 -0.160 12.2 -0.159 12.3 -0.158 12.4 -0.157 12.5 -0.157 14.1 -0.161 14.2 -0.159 14.3 -0.159 14.4 -0.158 14.5 -0.158 18.1 -0.134 18.2 -0.133 18.3 -0.132 18.4 -0.131 18.5 -0.131 20.1 -0.135 20.2 -0.134 20.3 -0.133 20.4 -0.132 Page: 20.5 -0.132 End of Report Page: 7 "SNIFF" 3.4 Copyright (c) Kidde-Fenwal USA, 2004 Isometric View #: 2 File Name: C:\Sniff\Projects\1309\COLO 6 NO Calculation Date/Time: 4/18/13 1:29:30 PM Page: 8 w H. SNF Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND 6 File Name: C:\Sniff\Projects\1309\COLO 6 SOUTH.SNF Calculation Date/Time: Apr 18, 2013, 1:30:34 PM Customer And Project Report ---- Distributor ---- Name: SUPPRESSION SYSTEMS INC. Address: 4417 PACIFIC HIGHWAY EAST : TACOMA, WA 98424 Phone: 253-926-3300 ---- Customer Name: TELX Address: 3433 SOUTH 120TH PLACE : BUILDING 14 : TUKWILA, WA 98168 Phone: Contact: Title: ---- Project --- Project: TELX COLO 5 AND 6 Designer: NINA M REEVES Number: 1309 Account: Location: COLO 6 SOUTH Desc.: RETURN AIR SAMPLING FOR 4 CRAB UNITS. Page: 1 Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND 6 - File Name: C:\Sniff\Projects\1309\COLO 6 SOUTH.SNF Calculation Date/Time: Apr 18, 2013e 1:30:34 PM Protected Area and Detector Report Protected Area Number : 1 Name : COLO 6 SOUTH Avg Temperature : 70 Static Pressure Differential : 0 Air Velocity Index : Above 10 and Below 20 Detector Name: AnaLASER Modular System without an Elutriator, without an Exhaust Port. Elevation: 0 feet (at sea level) Page: 2 Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND 6 File Name: C:\Sniff\Projects\1309\COLO 6 SOUTH.SNF Calculation Date/Time: Apr 18, 2013, 1:30:34 PM Parts List Report Detector Name: AnaLASER Modular System without an Elutriator, without an Exhaust Port. Pipe: Total: Total: 90° Elbows: Tees: Quantity Length Diameter Type 4 0.58 ft 3/4 in PVC 4 1.58 ft 3/4 in PVC 4 6.16 ft 3/4 in PVC 8 9.83 ft 3/4 in PVC 2 14.66 ft 3/4 in PVC 141.24 ft 1 5.83 ft 1 in PVC 1 8.00 ft 1 in PVC 1 14.66 ft 1 in PVC 28.49 ft 9 3/4 in PVC 1 1 in PVC 5 3/4 in PVC 1 3/4 in x 1 in x 3/4 in PVC 1 1 in x 1 in x 3/4 in PVC End Caps: 8 3/4 in PVC Page: 3 Copyright (c) Kidde-Fenwal USA, 2004 "SNIFF" 3.4 Project: TELX COLO 5 AND_6 File Name: C:\Sniff\ProjectsA1309\COLO 6 SOUTH.SNF Calculation Date/Time: Apr 18, 2013,1 1:30:34 PM Main Calculations Results Calculated Transport Time = 27.0 Maximum Allowable Transport Time = 120.0 Flow = 0.04581451 CF/Sec Seg-ISampleI Hole' Pipel PipelBran-I Hole 1 Ext.'Ext.1 Suction' % ofI Relat. mentlHole IDiameter1Diameter1 Len.Iches I Dist.IDiameterILen.IPressureiTotall Sensi- 1 I Flow' tivity 1 inches 1 inches I feet' 1 feet I lfeetlln Water' 1%ob/ft 1 3/4 in 0.0 1 2 1 in 8.0 1 3 1 in 5.8 2 4 3/4 in 6.2 2 5 3/4 in 0.6 1 6 3/4 in 9.8 0 7 8 6.1 6.2 6.3 6.4 6.5 8.1 8.2 8.3 8.4 8.5 5/64 in 5/64 in 5/64 in 5/64 in 5/64 in 5/64 in 5/64 in 5/64 in 5/64 in 5/64 in 3/4 in 1.6 1 3/4 in 9.8 0 9 1 in 14.7 1 2 10 3/4 in 6.2 2 11 3/4 in 0.6 1 12 3/4 in 9.8 0 12.1 12.2 12.3 12.4 12.5 5/64 in 5/64 in 5/64 in 5/64 in 5/64 in 13 3/4 in 1.6 1 14 3/4 in 9.8 0 14.1 14.2 14.3 14.4 14.5 5/64 in 5/64 in 5/64 in 5/64 in 5/64 in 15 3/4 in 14.7 1 2 16 3/4 in 6.2 2 17 3/4 in 0.6 1 18 3/4 in 9.8 0 18.1 18.2 18.3 18.4 18.5 3/32 in 3/32 in 3/32 in 3/32 in 3/32 in 19 3/4 in 1.6 1 20 3/4 in 9.8 0 20.1 20.2 20.3 3/32 in 3/32 in 3/32 in Page: 4 0.5 3/4 in 0.0 -0.389 2.54% .59161 2.5 3/4 in 0.0 -0.388 2.53% .59263 4.5 3/4 in 0.0 -0.387 2.53% .59339 6.5 3/4 in 0.0 -0.386 2.53% .59393 8.5 3/4 in 0.0 -0.386 2.52% .59421 0.5 3/4 in 0.0 -0.389 2.53% .59224 2.5 3/4 in 0.0 -0.387 2.53% .59327 4.5 3/4 in 0.0 -0.386 2.53% .59404 6.5 3/4 in 0.0 -0.386 2.52% .59457 8.5 3/4 in 0.0 -0.385 2.52% .59486 0.5 3/4 in 0.0 -0.299 2.22% .67488 2.5 3/4 in 0.0 -0.298 2.22% .67640 4.5 3/4 in 0.0 -0.297 2.21% .67753 6.5 3/4 in 0.0 -0.296 2.21% .67832 8.5 3/4 in 0.0 -0.296 2.21% .67875 0.5 3/4 in 0.0 -0.298 2.22% .67582 2.5 3/4 in 0.0 -0.297 2.21% .67735 4.5 3/4 in 0.0 -0.296 2.21% .67849 6.5 3/4 in 0.0 -0.295 2.21% .67929 8.5 3/4 in 0.0 -0.295 2.21% .67971 0.5 3/4 in 0.0 -0.165 2.38% .63140 2.5 3/4 in 0.0 -0.164 2.37% .63398 4.5 3/4 in 0.0 -0.163 2.36% .63593 6.5 3/4 in 0.0 -0.162 2.35% .63729 B.5 3/4 in 0.0 -0.161 2.35% .63802 0.5 3/4 in 0.0 -0.164 2.37% .63301 2.5 3/4 in 0.0 -0.163 2.36% .63562 4.5 3/4 in 0.0 -0.162 2.35% .63758 20.4 3/32 in 20.5 3/32 in 21 3/4 in 14.7 1 22 3/4 in 6,2 2 23 3/4 in 0,6 1 24 3/4 in 9.8 0 24.1 7/64 in 24.2 7/64 in 24.3 7/64 in 24.4 7/64 in 24.5 7/64 in 25 3/4 in 1.6 1 26 3/4 in 9.8 0 26.1 7/64 in 26.2 7/64 in 26.3 7/64 in 26.4 7/64 in 26.5 7/64 in Page: 5 6.5 3/4 in 0.0 -0'161 2.35% .63895 8.5 3/4 in 0.0 -0'16I 2.34% .63968 0.5 3/4 in 0.0 -0.135 2.93% .51236 2.5 3/4 in 0.0 -0.134 2.91% .51493 4.5 3/4 in 0.0 -0.133 2.90% .51686 6.5 3/4 in 0.0 -0.132 2.89% .51821 8.5 3/4 in 0.0 -0.132 2.89% .51894 0.5 3/4 in 0.0 -0.I34 2.92% .51396 2.5 3/4 in 0.0 -0.133 2.90% .51655 4.5 3/4 in 0.0 -0.132 2'89% '51850 6.5 3/4 in 0.0 -0.13I 2.89% ,51987 8.5 3/4 in 0.0 -0'131 2.88% ,52060 SUCTION PRESSURE MEASUREMENTS HOLE CALCULATED MEASURED NUMBER SUCTION PRESS. SUCTION PRESS. Inches of Water Inches of Water 6.1 -0.389 6.2 -0.388 6.3 -0.387 6.4 -0.386 6.5 -0.386 8.1 -0.389 8.2 -0.387 8.3 -0.386 8.4 -0.386 8.5 -0.385 12.1 -0.299 12.2 -0.298 12.3 -0.297 12.4 -0.296 12.5 -0.296 14.1 -0.298 14.2 -0.297 14.3 -0.296 14.4 -0.295 14.5 -0.295 18.1 -0.165 18.2 -0.164 18.3 -0.163 18.4 -0.162 18.5 -0.161 20.1 -0.164 20.2 -0.163 20.3 -0.162 20.4 -0.161 Page: 20.5 -0.161 24.1 -0.135 24.2 -0.134 24.3 -0.133 24.4 -0.132 24.5 -0.132 26.1 -0.134 26.2 -0.133 26.3 -0.132 26.4 -0.131 26.5 -0.131 End of Report Page: 7 'SNIFF" 3.4 ;opyright (c) Kidde-Fenwal USA, 2004 Esometric View #: 2 File Name: C:\Sniff\Projects\1309\COLO 6 SOUTH.SNF :alculation Date/Time: 4/18/13 1:30:34 PM ?age: 8 w AnaLASER M War Sys tem \\SEPIPEO1\Data\Projects\972 AboveNET\Shop Drawings-McKinstry\Fire Protection\as-buiks\972-firespk-ti.dwg, Layoutl, 5/13/2010 1:08:04 PM GENERAL NOTES 1. SPRINKLER SYSTEM DESIGN PER N.F.PA 113 2. ALL MATERIALS SHALL BE NEW AND U.L LISTED OR F.M. APPROVED 3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, HUNG, BRACED AND Ls ILL) IN ACCORDANCE WITH N.F.PA 113 4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILRY TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES CONTROWNG WATER SUPPLIES TO SPRINKLER SYSTEMS 5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM. 6. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. 7. SPRINKLER HEADS ARE TO BE LOCATED *2" OF CENTER OF TILE 8. NEW AND RELOCATED SPRINKLER HEADS ARE TO BE ON 1• DYNATHREAD OR SCHEDULE 40 ARM OVERS. 9. NEW MAINS AND NEW BRANCH ONES ARE TO MATCH EXISTING PIPE SIZING WHERE HYDRAUUC CALCULATIONS ARE NOT REQUIRED. 10. SPRINKLER HEADS HAVE BEEN ADDED AND RELOCATED TO ACCOMMODATE TENANT IMPROVEMENTS. AREAS OUTSIDE SCOPE OF WORK ARE TO REMAIN. 11. THE OWNER IS RESPONSIBLE FOR THE PERIODIC INSPECTION, TESTING, AND MAINTENANCE OF THESE FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 25 1995 EDITION. THIS WORK MUST BE DONE BY QUALIFIED PERSONNEL STARTING AFTER THE WARRANTY PERIOD HAS EXPIRED. THE COMPANY THAT DESIGNED AND INSTALLED THIS bmIl M IS THE BEST QUALIFIED TO PROVIDE THE ONGOING LONG TERM TESTING, SERVICING, AND MAINTENANCE OF THIS SYSTEM(S). SCOPE OF WORK 1. RELOCATE AND/OR ADD PENDENT SPRINKLERS TO ACCOMMODATE TENANT IMPROVEMENTS. 2. NEW SPRINKLERS ARE TO MATCH EXISTING QUICK RESPONSE, EXTENDED COVERAGE, PENDENT SPRINKLERS RATED AT 155F AND 14.0K. 3. ALL AREAS OUTSIDE SCOPE OF WORK ARE TO REMAIN AS IS AND UNAFFECTED BY TENANT IMPROVEMENT. SPRINKLER DETAILS BRANCHLINE STRUCTURE -\ HANGER 1" x ARMOVER SEE PLAN SUSPENDED CEILING -I PENDENT HEAD J RELOCATE DETAIL SPRINKLER LEGEND SYM 14 COLOR ESC RESPONSE �• K NPT MFG. MODEL # QTY ® EXISTING EC CHROME WHITE -- ^ 155°F 14.5 3/," �. ESLO N/A • RELOCATE EC CHROME WHITE u 155°F 14.5 %" CENTRAL ESLO 2 ®P ADD SSP CHROME WHITE ■ ° 5.6 /z" TYCO FRB \. QP PLUGGED HEADS 0 TOTAL AFFECTED 4 165 U o I-0 7144 `_ III ___ IN - ABOVE 14'-0.. � RAISED FLOOR ¢ : = • „ iii Ern (16'-6" ABOVE SLAB) Q . ■ Q . VIOA r�i-o .—. o . o . o 1 e. Emu_ Iliii1:1I' EC ABOVE - 2PIII -162 Illr_ , L•r1 1 �-\1 II 15• ow ❑i■i - —I 1 � .. 2 2 � _. Q 2 1- .. _ II 1 I ° M 11 1 II u EC 04 o' 154 C Wil a Ill' lij■ 14'-0" lilGWB cn --'(7b-6==AE�dIIE''TAr' 1 ABOVE RAISED FLOOR --.o.o.o. _ 0 - -- -- — EC �-- -- — -- :' -- — cn aQ - 153 C) L— -- — -- -- — -- — NEQ 43Fo II _.. 1 .;i_X1 SYM TYPE COLOR ESC RESPONSE TEMP K NPT MFG. MODEL # QTY ® EXISTING EC CHROME WHITE QR 155°F 14.5 3/," CENTRAL ESLO N/A • RELOCATE EC CHROME WHITE QR 155°F 14.5 %" CENTRAL ESLO 2 ®P ADD SSP CHROME WHITE QR 155°F 5.6 /z" TYCO FRB 2 QP PLUGGED HEADS 0 TOTAL AFFECTED 4 SPRINKLER PLAN — FIRST FLOOR 1/8' _= 1'-0 KEY PLAN ins tr, FIRE PROTECTION 5005 3RD AVE SOUTH P.O. BOX 24567 SEATTLE, WA. 98134 (206) 762-3311 TU 'KWILA 2 INTERNATIONAL GATEWAY BUILDING 4 3433 S. 120TH PLACE TUKWILA, WA 98168 DRAWN BY: JES CHECKED BY: JSS DATE: 5-13-10 McK. PROJECT NUMBER: 301686 Q QQ Q Q PPLO 1�1FIRE e 2 3 4 5 ,. T�Kw►� SHEET: FP -L01 -TI ACCEPTED o Without Comments As Noted in Red O Per The Arta d red Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards: Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. A. � litions, deletions or revisions to these drawingsyafter nIs dare will void this acceptance and will require a resubrroE.tai of revised drawings for subsequent approval. Fr& ,._ccepta; ic:e is subject to field test and inspection by: The Tukwik Fire Prevention Bureau. Date: Ste' f Y -10 By: 1 11AftWItA FIRE Dir.PART/MO.1 Please call: 575.4147 and give this job No. !O -s' o7j and exact address for shut. l wn or restoration approval FILE IO L 0 u EC TEL) DATA 119 I ®1-033 611430 A UPS ROOM 1 120 I 611.040 4.1-041 611-042 (r 1�� —EACILRIfs_CQITRDL 123 I 61-043 OPS TECH WORK AREA 1 124 C04.01 134 IL 7 BREAK ROOM 175 I C nD 1.114 LOBBY( WAITING 183 1 ONF. ROOM 3 187 SECURIP RN 184 I(" UNASSIGNED 183A 1 tr— SCOPE OF WORK FOR: COLO 1 OFFICE AREA AND LOBBY AREA AS FOLLOWS: 1) AREA °A' ABOVE. THE EXISTING T -BAR CEIUNG HAS BEEN REMOVED. SSI RELOCATED ALL EXISTING SMOKE DETECTORS IN THESE AREA TO THE STRUCTURE. 2) AREA'D' 881 RELOCATE 2 EXISTING SMOKE DETECTOR IN THE LOBBY AREA. 1 T.I. FIRE ALARM PLAN COLO 1 / OFFICE AREA SCALE:1 /W =11-0' 1 j A B AREA MAP SCALE: NTS uu LJu EC n1 164 I SECURITY HEAD END 155A 1 EC L 1 153 1 OPSICUSTOMER _WORN ABEe 7 OW 'NW II II 8 LJu uu Mk;,• ,;�.�1ti O C04.0 6 166 1 C04.0 5 1 152 1 MFN I 160 1 408 s DC PLANTA 159A 1 1598 C PLANT 8 0 5B'-1 1 /4' 58'-0 1/2' 5x11 1 /2' COLO 5 AND 6 RETURN AIR - AIR SAMPLING PLAN SCALE: 1/8* - r-0' SCOPE OF WORK FOR COLO 5 AND 6 AS FOLLOWS: 1) SUPPRESSION SYSTEMS INC (SSI) SHALL DEMO EXISTING ANALASER AIR SAMPLING PIPE TO THE EXISTING CRAH UNITS. 2) THE EXISTING 3 DETECTORS SHALL REMAIN ON THE WALL AT THEIR CURRENT LOCATIONS AND BE REUSED. 3) A FOURTH UNIT FOR THE COLO 8 NORTH 3 CRAH UNITS WILL BE SUPPUED BY OWNER AND INSTALLED BY SSI. 4) AFTER THE NEW CRAH UNITS ARE PUT IN PLACE SSI SHALL RE -INSTALL THE AIR SAMPUNG PIPE NETWORK FOR RETURN AIR SAMPUNG PER THE REVISED CALCULATIONS PROVIDE HERE. TUT • 04/18/13 FAIR NMR EST AS NOTED REVIMON /01:111.1.v NWLT SUP#:SSION SYSTEMS INC. SPEOAL HAZARD RITE un PAO1F10 HIGHWAY EAST TACOMA WA 86124.2811 90319293300 FAX 12531 920-3330 PROJECT NNIS TE 3433 SO. 120TH P CRAHSUNIT R PUNG DETECTION COVER SHEET NOTES AND DETAILS JOB NUMBER JOB 1309 FP -2 „/3 LE KWILA. WA 98188 FLAGNOTES PANEL 2 RX TX LOOP 3 ACQUIRED FROM CO -L0-1 2. INSTALL NEW ADDRESSABLE MONITOR MODULE TO MONITOR FACTORY INSTALED DUCT DETECTOR AT NEW AHU UNIT AS A SUPERVISORY INPUT. A SPARE ADDRESS IS TO BE ASSIGNED AND DOCUMENTED FOR AS BUILT DRAVANGS. SEE DETAIL 4. 3. ACQUIRE PANEL 2, RX/TX LOOP 3 FROM THIS EXISTING DEVICE FOR TO NEW ADDRESSABLE MONITOR MODULE LOCATED AT NEW AHU UNIT. 4. NEW WIRE INSTALLED UNDER JOB# 09-1870. NOTE: THE ONLY CHANGES UNDER REV B JOB # 09-1870 / ARE SHOWN IN REVISION CLOUDS. ALL OTHER > EQUIPMENT SHOWN ON THIS SHEET ARE EXISTING AND ARE NOT CHANGED BY THIS REVISION. 57'-11i• 57'-11 PRE -ACTION SPRINKLER ZN. 5 DISCHARGE PLENUM DISCHARGE PLENUN RPU ENCLOSURE Ell DISCHARGE PLENUM '® PRE -ACTION SPRINKLER ZN. 4 RPU ENCLOSURE 1 1021 RPU ENCLOSURE O CORRIDOR 1 1041 Cr?) rot DOCK RECEMNG F01 5 ES FO1 F01 DOCK SEC. ED F01 2#16 DR FO FO1 WO EN ro1 D5 D4 1 1091 D3 FOt 12 KID� EC TEL/DAIA( JANITOR ro1 191 F01 MAINTENANCE GARAGE EDI 1 D2 11071 CID 2#16 18" BFAM D1 F01 MAINTENANCE SHOP FO1 Oz F01 4E1 OFFICE FOt F01 FO1 F01 2816 CORRIDOR 1 105 1 oEEE F01 tjaw rot 1 F01 FACILITY (=f) CONTROL ES F0 1 1231 � 2 P #16 to ❑1 ELECTRICAL \.ROOM M3 �� a, ' QED DA -ER 1 131 1 REL FO 411EDI--1 F01fII3) 0 0 El . moi) F QED12 ELECTRICAL El ROOM M2 © 00> 1 1�0 ' 2116- ,7 3( 1� ygi -/ n DAMPER RELAY-1 ELECTRICAL tg z (3193] ith) ROOM 61 El 18" BFAM 1 1291 0 2#16 6'P DAMP 17 RELA ELECTRICAL FF0011 ROOM MR 0191 El 1 1281 2 ( z2 ® �1 4 DAMPER RELAY) CRITICAL EQUIPMENT 1 1251 T Q 10 Fm OPS TECH Fm WORK AREA 1 1241 FPI F01 2116 4116 FO1 0215 ELECTRICAL EMERGENCY ROOM 2116 ELECTRICAL EMERGENCY R00 112761 ELECTRICAL BY-PASS ROOM 1 1261 1 5 1 O BAS BMS 1221 I4 CO -LU -1 KIOSK 12 2-116 TYP PRE -ACTION SPRINKLER ZN. 4 X x Q LI W LJ -I 0 0 LEGEND Q ADDRESSABLE PHOTO SMOKE DETECTOR Q ADDRESSABLE HEAT DETECTOR ADDRESSABLE INPUT MODULE E ADDRESSABLE OUTPUT RELAY MODULE O ALARMLINE/FN2000 INTERFACE MODULE El ADDRESSABLE PULL STATION a ADDRESSABLE DEVICE ADDRESS DEVICE NUMBER LOOP NUMBER ADDRESS REFERENCE 0 SCALE NTS RXTX (+) - IN (-) t -ILL L,L Y POWER PROMDED BY MCKINSTRY ELECTRIC DUCT OE1ECTCR IMO l20 M01 w 1R •1-1 T1y WC SHUT DOWN AHU W 1.1 I�11-1 DH400ACDC DUCT SMOKE DETECTOR SCALE NTS TO ADDRESSABLE Al MODULE INPUT FOR MANUAL STATION OR OTHER CONTACT DEVICE 10K AIMS 1/2 W 1E011 111 1 X U. U,U,UIUIUIU nnonnnno ADDRESSABLE DETECTOR EQUIPMENT SHUTDOWNS NNE SIN 0•111,IL1 nITOOHRE TYPICAL INITIATING LOOP WIRING DETAIL M SCALE: NTS CEILING ADDRESS PLAN — AREA 101 SCALE 1/8"-11 • • 0 0 • • • IT %ifAr/ KEY PLAN (+ RXTX ( OUT PAID DRAM BY: JSL DATE 12/09/08 PROJECT MGR: JS APPROVED BY: RFV OF SHEETS 1 gi PROJECT DESCRIPTION: FIRE ALARM REVISIONS TO EXISTIN SHEET DESCRIPTION: CEILING ADDRESS PLAN - AREA 1 - 08-1690 OJ 6 611 JUL -7 200908-1690 11 DRAMMG NO' ^S1k1.Nll�' FIreFA-05.1.dwg 2Cr757' FA5.1 175 ACCEPTED ( Without Comments 0 As Noted in Red 0 Per T e Attached Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for c;nformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 7 -O 61 By: c ri EUtit�;tLA FIRE DEPARTMM%t Please call: 575.4407 and give this job No. 01-F- /v!0 and exact address for shut. -,• awr+ or •es`';,rdtion aDoroval NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee an) termination of the testing • GUARDIAN SECURITY Seattle - Tacoma - Poulsbo - Bellingham FILE November 29, 2012 City of Tukwila Fire Department Headquarters- Station 51 444 Andover Park East Tukwila, WA 98188 RE: Installing AES Radio Transmitter 1743 First Avenue South Seattle, WA 98134 Tel: 206.622.6545 Fax: 206.341.9928 T mn.A FIRE E DEPAR T,wI Please call 206-575-4,107 a d give F Fire -iPermit NO. and enact address for shut- down or restoration approval. Guardian security would like to install an AES Radio Transmitter to monitor the existing FACP (Fenwall Net 2000ML) for monitoring. Northwest Alarm Central Station located at 1743 First Avenue South, Seattle, WA 98134 will be monitoring the following address: Intergate East 3433 South 120th Place Tukwila, WA 98188 Thank you, Traci Adams Guardian Security 1743 First Ave. South Seattle, WA 98134 Phone: 206-622-6545 Ext: 217 Email: tadams@guardiansecurity.com NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection F<<e and termination of the testing. W t out Comments As Noted ';l Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire r,revention Bureau fr co-;:`ormancF ,,,);c.-; current City Acceprr,.-,(1: is s.lniect tc error's and ()missions which ,,'.)i; t on°,- of adopted -:3ndards and ar rl .' _ r . ponsib lsty for the a <ieQuacy of dean:. :. ,e :Jesigner. , dditior � deleb U; , ?Y°i: ' i i u. i r es drawings after this date will void 11.-.s :,:ceptar7ceane: wily require a resubmittal of revised drawings fo subsequent approval. Final acceptance is suolf?ct to fi•.._d test and inspection by Tne Tukwila Fire Prevt:nt,on 3u, eau. Date: // -`� 9 Bv: / r PAID NOV 29 2012 TUKWILA FIRE ec ,x/00 // nz / S c./5F' AIR SAMPLING INSTALLATION INSTRUCTIONS: 1. AIR SAMPLING PIPE NETWORK CALCULATIONS SHALL BE PROVIDED BY SUPPRESSION SYSTEMS INC. 2. ALL SOLVENT CEMENTED CONNECTIONS SHALL BE ASSEMBLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. 3. MAXIMUM SUPPORT SPACING FOR SAMPLING PIPES SHALL NOT EXCEED 5FT. HANGERS AND SUPPORTS USED SHALL BE FREE OF ROUGH OR SHARP EDGES AND SHALL NOT BIND THE PIPE FROM MOVEMENT. 4. END CAPS SHALL BE SOLVENT CEMENTED TO EACH SAMPLING PIPE, AND DRILLED WITH A HOLE AS SPECIFIED BY THE AIR SAMPLING DESIGN PROGRAM. 5. SAMPLING HOLES SHALL BE APPROPRIATELY SIZED TO ACHIEVE THE SPECIFIED SYSTEM PERFORMANCE AS SPECIFIED AND CALCULATED BY THE SYSTEM DESIGN. 6. SAMPLING POINTS SHALL NOT BE SPACED AT MORE THAN 30FT INTERVALS. 7. EACH SAMPLING POINT SHALL BE IDENTIFIED WITH A LABEL. 8. MINIMUM O.D. OF ALL CAPILLARY TUBE SHALL BE 3/8". 9. MAXIMUM LENGTH OF ANY CAPILLARY TUBE SHALL NOT EXCEED 20FT. 10. THE CAPILLARY TUBE SHALL TERMINATE AT AN APPROVED CEILING SAMPLING POINT. 11. THE PIPE MUST BE CUT SQUARE. CUTTING THE PIPE AS SQUARELY AS POSSIBLE PROVIDES A MAXIMUM BONDING AREA. PIPE CAN BE CUT EASILY WITH A WHEEL -TYPE PLASTIC TUBING CUTTER RATCHET STYLE CUTTER OR FINE TOOTHED SAW. CARE MUST BE TAKEN NOT TO SPLIT THE PIPE IF A RATCHET TYPE CUTTER IS USED, PARTICULARLY AT COLDER TEMPERATURES. 12. REMOVE ALL BURRS AND FILINGS, AND PLACE A SLIGHT BEVEL ON THE PIPE END. A FILE OR CHAMFERING TOOL IS SUITABLE FOR THIS PURPOSE. A PROPER BEVEL WILL EASE ENTRY OF THE PIPE INTO THE FITTING SOCKET AND PREVENT SOLVENT CEMENT FROM BEING WIPED FROM THE JOINING SURFACES DURING ASSEMBLY. 13. WIPE LOOSE DIRT AND MOISTURE FROM THE FITTING SOCKET AND PIPE END BY USING CLEAN DRY RAG. CHECK THE "DRY FIT" OF THE COMPONENTS BEING JOINED TO ENSURE COMPATIBILITY. THE PIPE SHOULD ENTER THE FITTING SOCKET 1/4 TO 3/4 OF THE WAY. IF THE PIPE BOTTOMS WITH LITTLE INTERFERENCE FIT USE EXTRA SOLVENT CEMENT WHEN MAKING THE JOINT. 14. USING THE APPROPRIATE SIZE APPLICATOR (A DAUBER OR NATURAL BRISTLE BRUSH 1/2 THE SIZE OF THE PIPE DIAMETER BEING JOINED) APPLY A HEAVY EVEN COAT OF ONE-STEP CEMENT TO THE OUTSIDE PIPE END WHILE WORKING INTO THE SURFACE. APPLY A MEDIUM COAT OF CEMENT TO THE FITTING SOCKET. IF THERE WAS LITTLE INTERFERENCE DURING THE DRY FIT APPLY A SECOND COAT OF CEMENT TO THE PIPE END AT THIS TIME. IT IS IMPORTANT TO WORK QUICKLY SO THAT THE CEMENT IS STILL LIQUID (TO ALLOW SURFACES TO SLIDE) WHEN PIPE AND FITTING ARE ASSEMBLED. 15. IMMEDIATELY INSERT THE PIPE COMPLETELY INTO THE FITTING SOCKET WHILE ROTATING THE PIPE 1/4 TURN. PROPERLY ALIGN THE FITTING FOR INSTALLATION AT THIS TIME. THE PIPE MUST BOTTOM TO THE FITTING STOP. HOLD THE ASSEMBLY FOR 10 TO 15 SECONDS TO ENSURE INITIAL BONDING. A CONTINUOUS BEAD OF CEMENT SHOULD BE EVIDENT AROUND THE JOINT. 16. WIPE OFF EXCESSIVE CEMENT WITH A RAG (EXCESSIVE CEMENT CAN CAUSE OVER -SOFTENING RESULTING IN DAMAGE). THE ASSEMBLY MUST BE ALLOWED TO SET WITHOUT ANY STRESS ON THE JOINT FOR 1 TO 5 MINUTES. 17. THE ASSEMBLIES MUST BE ALLOWED TO CURE PROPERLY PRIOR TO USE. CURE TIMES ARE AS FOLLOWS FOR 3/4" TO 1" CPVC: 0°F THRU 30°F = 48 HOURS 40°F THRU 59°F = 4 HOURS 60°F THRU 120°F = 1 1/2 HOURS 0 0 COMMelltS As itis ,i. •d In { a1ed Per The Attach,2,d Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau iur r-tura+-oemance. wstb current City standards. Ac p t j_:;` is sub.1ec` t'o c;rrors and onlission3 which a?o nutC:o i e violations of adopted standards and orair.o ce::. The responsibility for the adequacy of de_;igr: o:,:w totally s e}1 thoe..:,� i finer. Additions, deletioii drawings after this date will void {.f's[uacceptance and wHi require a resubmittal or revised d a,:vlr+ js for subsequent approval. Final acceptance is subject to field test and inspection by, The Tukwila mire Prevention Bureau. /-'/c7 -13 l Date: By: 4 -0144 -fah 4hdl hs1-.,-) 4b W>^.�/ w;k� NFeA• 7). sec ./.7.)•'3•L DRAWING INDEX : FP- 1 - COVER SHEET, NOTES AND DETAILS FP- 2 - FLOOR PLANS FP- 3 - ISOMETRIC PLANS PROJECT DATA OWNER / SITE: TELX SEATTLE 3433 SOUTH 12TH PLACE BUILDING 4 TUKWILA, WASHINGTON 98168 AHJ: CITY OF TUKWILA 444 ANDOVER PARK EAST KUKWILA, WA 98188 PHONE: 206-575-4404 APPLICABLE CODES : NFPA 702011 NFPA 722010 INTERNATIONAL FIRE CODE 2009 INTERNATIONAL BUILDING CODE 2009 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEP/T. Please call 2O6-57:..4 O7 and give this Fire Per mft No. and `exact address for shut- down or restoration approval. LEGEND / PARTS LIST SYMBOL QUAN. PART # DESCRIPTION MANUFACTURER ENCLOSURE NOTES ANLA 4 EXISTING ANALASER I AIR SAMPLING DETECTOR FENWAL 4S BOX OR 2 GANG �h- 80' CPVC 1" CPVC PIPE, 15' LENGTH BOX 210' EACH FENWAL 3 90° X 1" 1" CPVC ELBOW, 90° FENWAL 4 TEE 1" 1" CPVC TEE • FENWAL 7 COUPLING 1" 1" CPVC COUPLING FENWAL 10 REDUCER 1" X 3/4" REDUCER FENWAL 600' CPVC 3/4" CPVC PIPE, 15' LENGTH BOX 210' EACH FENWAL 35 90° X 3/4" 3/4" CPVC ELBOW, 90° FENWAL 22 TEE 3/4" 3/4" CPVC TEE FENWAL 30 END CAP 3/4" 3/4" CPVC END CAP FENWAL 40 COUPLING 3/4" 3/4" CPVC COUPLING FENWAL Score a& wo,e; is 10 hor/aGe 01d 5441010;44 r; SCOPE OF WORK FOR COLO 1 OFFICE AREA AS FOLLOWS: 1) THE AREA OUTLINED ABOVE, THE EXISTING T -BAR CEILING HAS BEEN REMOVED. SSI RELOCATED ALL EXISTING SMOKE DETECTORS IN THESE AREA TO THE STRUCTURE. T.I. FIRE ALARM PLAN COLO 1 / OFFICE AREA 41 SCALE: 1/8" = 1'-0" B AREA MAP SCALE: NTS co N 11 JI' 1I 1, 11 til I I I I II �•���m� B F.s0_04 CRAH-601 L TAH -607 0 EC 164 _itSECURITY HEAD END 155A JO- OPSICUSTOMER _WORK AREA_—_ 156 EC 153 ER PO 6 CRAH-503 5 E. ®_ CRAH-605 JED' CO -LO 6 166 CO -LO 5 152 E■.;KAH-OU4 er Eo o o DATA 158 O co N MFN 160 STORAGE 160A TECH i' 160B PLANT A 159A 159B �C PLANT B .,-O 0 COLO 5 AND 6 RETURN AIR — AIR SAMPLING PLAN SCALE: 1/8" = SCOPE OF WORK FOR COLO 5 AND 6 AS FOLLOWS. 1) SUPPRESSION SYSTEMS INC (SSI) SHALL DEMO EXISTING ANALASER AIR SAMPLING PIPE TO THE EXISTING CRAH UNITS. 2) THE EXISTING 3 DETECTORS SHALL REMAIN ON THE WALL AT THEIR CURRENT LOCATIONS AND BE REUSED. 3) A FOURTH UNIT FOR THE COLO 6 NORTH 3 CRAH UNITS WILL BE SUPPLIED BY OWNER AND INSTALLED BY SSI. 4) AFTER THE NEW CRAH UNITS ARE PUT IN PLACE SSI SHALL RE -INSTALL THE AIR SAMPLING PIPE NETWORK FOR RETURN AIR SAMPLING PER THE REVISED CALCULATIONS PROVIDE HERE. E Protection Systems A UTC Fire & Security Company SUPFPESSION SYSTEMS, INC. SPECIAL HAZARD FIRE PROTECTION 4417 PACIFIC HIGHWAY EAST TACOMA, WA 98424-2611 (253) 926-3300 FAX (253) 926-3306 NO. DATE REVISION BY DATE: DRAWN: NMR CHECKED: NMR APPROVED BY: ZST PROJECT NAME: TELX SEATTLE 3433 SO. 120TH PLACE BLDG 4, TUKWILA, WA 98168 SCALE: AS NOTED A NO. DATE REVISION BY SHEET TITLE: CRAH UNIT RETURN AIR SAMPLING DETECTION COVER SHEET NOTES AND DETAILS A JOB NUMBER: JOB 1309 FP -1 of/ COLOCATE 6 N.E. 4 UNITS SAMPLING HOLE # HOLE DIA. (INCH) SAMPLING HOLE # HOLE DIA. (INCH) 6.1 5/64 18.1 3/32 6.2 5/64 18.2 3/32 6.3 5/64 18.3 3/32 6.4 5/64 18.4 3/32 6.5 5/64 18.5 3/32 8.1 5/64 20.1 3/32 8.2 5/64 20.2 3/32 8.3 5/64 20.3 3/32 8.4 5/64 20.4 3/32 8.5 5/64 20.5 3/32 12.1 5/64 24.1 7/64 12.2 5/64 24.2 7/64 12.3 5/64 24.3 7/64 12.4 5/64 24.4 7/64 12.5 5/64 24.5 7/64 14.1 5/64 26.1 7/64 14.2 5/64 26.2 7/64 14.3 5/64 26.3 7/64 14.4 5/64 26.4 7/64 14.5 5/64 26.5 7/64 SYSTEM RESULTS: CALCULATED TRANSPORT TIME = 26.4 SEC CALCULATED SYSTEM FLOW = 0.03176498 CF /SEC MINIMUM RELATIVE SENSITIVITY = 0.42115% OB / FT MAXIMUM RELATIVE SENSITIVITY = 0.48352% OB / FT 1"X5'-10" 1"X3/4" 1" X 14'-8" COLOCATE 6 N.W. 3 UNITS SAMPLING HOLE # HOLE DIA. (INCH) SAMPLING HOLE # HOLE DIA. (INCH) 6.1 5/64 18.1 3/32 6.2 5/64 18.2 3/32 6.3 5/64 18.3 3/32 6.4 5/64 18.4 3/32 6.5 5/64 18.5 7/64 8.1 5/64 20.1 3/32 8.2 5/64 20.2 3/32 8.3 5/64 20.3 3/32 8.4 5/64 20.4 3/32 8.5 5/64 20.5 3/32 12.1 3/32 24.1 3/32 12.2 3/32 24.2 3/32 12.3 3/32 24.3 3/32 12.4 3/32 24.4 3/32 12.5 3/32 24.5 3/32 14.1 3/32 26.1 3/32 14.2 3/32 26.2 3/32 14.3 3/32 26.3 3/32 14.4 3/32 26.4 3/32 14.5 3/32 26.5 3/32 SYSTEM RESULTS: CALCULATED TRANSPORT TIME = 27.0 SEC CALCULATED SYSTEM FLOW = 0.04581451 CF /SEC MINIMUM RELATIVE SENSITIVITY = 0.51236% OB / FT MAXIMUM RELATIVE SENSITIVITY = 0.67971 % OB / FT 1" X 3/4" 1" X 3/4" 3/4" X 14'-8" 3/4" X 14'-8" 000` 3/4" X 14'-8" 3/4" X 14'-8" _-* - 7 7 3/4" X 20'-5" 3/4" X 6'-2" TYP. 7 7 7 7 7 7 7 7 7 7 7 7 N T t O f0 COLO 6 SOUTH 3/4" X 1" vi EXTEND TO EDGE OF UNIT SOLID END CAP 3/4" x 2'-0" 3/4" x 2'-0" 3/4" x 2'-0" 3/4" x 0'-6" AIR SAMPLING DETECTOR COLOCATE 6 SOUTH RETURN AIR TEST POINT TRANSPORT TIME 26.4 SECONDS AIR SAMPLING DETECTOR COLOCATE 6 NORTH RETURN AIR TEST POINT TRANSPORT TIME 27.0 SECONDS EXTEND TO EDGE OF UNIT SOLID END CAP 3/4" X 2'-0" 3/4" X 2'-0" 3/4" X 2'-0" 3/4" X 2'-0" 3/4" X 0'-6" TYPICAL SOUTH UNITS 1"X5'-10" 3/4" X 14'-8" 1" X 3/4" 1" X 3/4" 3/4" X 14'-8" 3/4" X 14'-8" 7 3/4" X 8'-2" TYP. i�COLO 6 NORTH 3/4" X 0'-6" 3/4" X 2'-0" 3/4" X 2'-0" 3/4" X 2'-0" 3/4" X 2'-0" EXTEND TO EDGE OF UNIT SOLID END CAP cke- 3/4" X 0'-6" 3/4" X 2'-0" 3/4" X 2'-0" 3/4" X 2'-0" 3/4" X 2'-0" EXTEND TO EDGE OF UNIT SOLID END CAP TYPICAL NORTH UNITS 3/4" X 1 4'-8" 7 7 7 3/4" X 14'-8" NOTES: 1) ALL PIPE SHALL BE 3/4" CPVC UNLESS NOTED OTHERWISE. 2) SYSTEM SHALL BE RETURN AIR SAMPLING. RETURN AIR GRILL LOCATED ON THE TOP OF THE CRAH UNITS. 3)SYSTEM LIMITS: A) MAXIMUM TRANSPORT TIME 120 SECONDS. B)4 SQ. FT. AREA OF COVERAGE PER SAMPLING PORT. 4)SYSTEM CALCULATIONS: GRILL 122" X 42"= 5,124 SQ. IN. / 144 SQ. IN. = 35.6 SQ. FT. 35.6SQ. FT / 4 SQ. FT. = 8.9 SAMPLING HOLES 10 HOLES PROVIDED. 1"X3/ 1" x 3/4" 3/4" X 14'-8 / 1" X 21'-5" LEGEND Q PIPE SEGMENT NUMBER X.X SAMPLING POINT NUMBER ® SAMPLING POPINT V REDUCER 6.2 SOLID END CAPS 7, 1" X 8'-2" TYP. 3/4" X 1" - 3/4" X 6'-2" TYP. 7, 7, 7, 7, AIR SAMPLING DETECTOR COLOCATE 5 SOUTH RETURN AIR TEST POINT TRANSPORT TIME 31.6 SECONDS 7, N f (1_2. io 1 ,,COLO 5 SOUTH 3/4"X 1" vi AIR SAMPLING DETECTOR COLOCATE 5 NORTH RETURN AIR TEST POINT TRANSPORT TIME 34.8 SECONDS COLOCATE 5 S.E. 4 UNITS SAMPLING HOLE # HOLE DIA. (INCH) SAMPLING HOLE # HOLE DIA. (INCH) 6.1 1/16 18.1 3/32 6.2 1/16 18.2 3/32 6.3 1/16 18.3 3/32 6.4 1/16 18.4 3/32 6.5 1/16 18.5 3/32 8.1 1/16 20.1 3/32 8.2 1/16 20.2 3/32 8.3 1/16 20.3 3/32 8.4 1/16 20.4 3/32 8.5 1/16 20.5 3/32 12.1 5/64 24.1 3/32 12.2 5/64 24.2 3/32 12.3 5/64 24.3 3/32 12.4 5/64 24.4 3/32 12.5 5/64 24.5 3/32 14.1 5/64 26.1 3/32 14.2 5/64 26.2 3/32 14.3 5/64 26.3 3/32 14.4 5/64 26.4 3/32 14.5 5/64 26.5 3/32 COLO 5 NORTH SYSTEM RESULTS: CALCULATED TRANSPORT TIME = 31.6 SEC CALCULATED SYSTEM FLOW = 0.03755569 CF /SEC MINIMUM RELATIVE SENSITIVITY = 0.52627% OB / FT MAXIMUM RELATIVE SENSITIVITY = 0.69269% OB / FT COLOCATE 5 N.E. 4 UNITS SAMPLING HOLE # HOLE DIA. (INCH) SAMPLING HOLE # HOLE DIA. (INCH) 6.1 1/16 18.1 3/32 6.2 1/16 18.2 3/32 6.3 1/16 18.3 3/32 6.4 1/16 18.4 3/32 6.5 1/16 18.5 3/32 8.1 1/16 20.1 3/32 8.2 1/16 20.2 3/32 8.3 1/16 20.3 3/32 8.4 1/16 20.4 3/32 8.5 1/16 20.5 3/32 12.1 5/64 24.1 3/32 12.2 5/64 24.2 3/32 12.3 5/64 24.3 3/32 12.4 5/64 24.4 3/32 12.5 5/64 24.5 3/32 14.1 5/64 26.1 3/32 14.2 5/64 26.2 3/32 14.3 5/64 26.3 3/32 14.4 5/64 26.4 3/32 14.5 5/64 26.5 3/32 SYSTEM RESULTS: CALCULATED TRANSPORT TIME = 34.8 SEC CALCULATED SYSTEM FLOW = 0.03572464 CF /SEC MINIMUM RELATIVE SENSITIVITY = 0.52099% OB / FT MAXIMUM RELATIVE SENSITIVITY = 0.71075% OB / FT FE Protection Systems A UTC Fire & Security Company SUPIPESSION SYSTEMS, INC. SPECIAL HAZARD ARE PROTECTION 4417 PACIFIC HIGHWAY EAST TACOMA, WA 98424-2611 . (253) 926-3300 FAX (253) 926-3306 NO. DATE REVISION BY DATE: DRAWN: NMR CHECKED: NMR APPROVED BY: ZST PROJECT NAME: TELX SEATTLE 3433 SO. 120TH PLACE BLDG 4, TUKWILA, WA 98168 SCALE: AS NOTED NO. DATE REVISION BY SHEET TITLE: CRAH UNIT RETURN AIR SAMPLING DETECTION COVER SHEET NOTES AND DETAILS JOB NUMBER: JOB 1309 FP -1 of/ AIR SAMPLING INSTALLATION INSTRUCTIONS: 1. AIR SAMPLING PIPE NETWORK CALCULATIONS SHALL BE PROVIDED BY SUPPRESSION SYSTEMS INC. 2. ALL SOLVENT CEMENTED CONNECTIONS SHALL BE ASSEMBLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. 3. MAXIMUM SUPPORT SPACING FOR SAMPLING PIPES SHALL NOT EXCEED 5FT. HANGERS AND SUPPORTS USED SHALL BE FREE OF ROUGH OR SHARP EDGES AND SHALL NOT BIND THE PIPE FROM MOVEMENT. 4. END CAPS SHALL BE SOLVENT CEMENTED TO EACH SAMPLING PIPE, AND DRILLED WITH A HOLE AS SPECIFIED BY THE AIR SAMPLING DESIGN PROGRAM. 5. SAMPLING HOLES SHALL BE APPROPRIATELY SIZED TO ACHIEVE THE SPECIFIED SYSTEM PERFORMANCE AS SPECIFIED AND CALCULATED BY THE SYSTEM DESIGN. 6. SAMPLING POINTS SHALL NOT BE SPACED AT MORE THAN 30FT INTERVALS. 7. EACH SAMPLING POINT SHALL BE IDENTIFIED WITH A LABEL. 8. MINIMUM O.D. OF ALL CAPILLARY TUBE SHALL BE 3/8". 9. MAXIMUM LENGTH OF ANY CAPILLARY TUBE SHALL NOT EXCEED 20FT. 10. THE CAPILLARY TUBE SHALL TERMINATE AT AN APPROVED CEILING SAMPLING POINT. 11. THE PIPE MUST BE CUT SQUARE. CUTTING THE PIPE AS SQUARELY AS POSSIBLE PROVIDES A MAXIMUM BONDING AREA. PIPE CAN BE CUT EASILY WITH A WHEEL -TYPE PLASTIC TUBING CUTTER RATCHET STYLE CUTTER OR FINE TOOTHED SAW. CARE MUST BE TAKEN NOT TO SPLIT THE PIPE IF A RATCHET TYPE CUTTER IS USED, PARTICULARLY AT COLDER TEMPERATURES. 12. REMOVE ALL BURRS AND FILINGS, AND PLACE A SLIGHT BEVEL ON THE PIPE END. A FILE OR CHAMFERING TOOL IS SUITABLE FOR THIS PURPOSE. A PROPER BEVEL WILL EASE ENTRY OF THE PIPE INTO THE FITTING SOCKET AND PREVENT SOLVENT CEMENT FROM BEING WIPED FROM THE JOINING SURFACES DURING ASSEMBLY. 13. WIPE LOOSE DIRT AND MOISTURE FROM THE FITTING SOCKET AND PIPE END BY USING CLEAN DRY RAG. CHECK THE "DRY FIT" OF THE COMPONENTS BEING JOINED TO ENSURE COMPATIBILITY. THE PIPE SHOULD ENTER THE FITTING SOCKET 1/4 TO 3/4 OF THE WAY. IF THE PIPE BOTTOMS WITH LITTLE INTERFERENCE FIT USE EXTRA SOLVENT CEMENT WHEN MAKING THE JOINT. 14. USING THE APPROPRIATE SIZE APPLICATOR (A DAUBER OR NATURAL BRISTLE BRUSH 1/2 THE SIZE OF THE PIPE DIAMETER BEING JOINED) APPLY A HEAVY EVEN COAT OF ONE-STEP CEMENT TO THE OUTSIDE PIPE END WHILE WORKING INTO THE SURFACE. APPLY A MEDIUM COAT OF CEMENT TO THE FITTING SOCKET. IF THERE WAS LITTLE INTERFERENCE DURING THE DRY FIT APPLY A SECOND COAT OF CEMENT TO THE PIPE END AT THIS TIME. IT IS IMPORTANT TO WORK QUICKLY SO THAT THE CEMENT IS STILL LIQUID (TO ALLOW SURFACES TO SLIDE) WHEN PIPE AND FITTING ARE ASSEMBLED. 15. IMMEDIATELY INSERT THE PIPE COMPLETELY INTO THE FITTING SOCKET WHILE ROTATING THE PIPE 1/4 TURN. PROPERLY ALIGN THE FITTING FOR INSTALLATION AT THIS TIME. THE PIPE MUST BOTTOM TO THE FITTING STOP. HOLD THE ASSEMBLY FOR 10 TO 15 SECONDS TO ENSURE INITIAL BONDING. A CONTINUOUS BEAD OF CEMENT SHOULD BE EVIDENT AROUND THE JOINT. 16. WIPE OFF EXCESSIVE CEMENT WITH A RAG (EXCESSIVE CEMENT CAN CAUSE OVER -SOFTENING RESULTING IN DAMAGE). THE ASSEMBLY MUST BE ALLOWED TO SET WITHOUT ANY STRESS ON THE JOINT FOR 1 TO 5 MINUTES 17. THE ASSEMBLIES MUST BE ALLOWED TO CURE PROPERLY PRIOR TO USE. CURE TIMES ARE AS FOLLOWS FOR 3/4" TO 1" CPVC: 0°F THRU 30°F = 48 HOURS 40°F THRU 59°F = 4 HOURS 60°F THRU 120°F = 1 1/2 HOURS DRAWING INDEX : FP- 1.1 - NOTES, LEGEND, PARTS LIST, MAPS AND DRAWING INDEX FP- 1.2 - DETAILS AND SEQUENCE OF OPERATION FP- 2.1 - CONTROLS PLAN FP- 2.2 - HSSD PIPING PLAN FP- 3.1 - HSSD ISOMETRICS COLO 3 FP- 3.2 - HSSD ISOMETRICS COLO 4 PROJECT DATA : OWNER / SITE: SABEY 3433 SOUTH 120TH PLACE BUILDING 4 TUKWILA, WASHINGTON 98168 AHJ: CITY OF TUKWILA 444 ANDOVER PARK EAST TUKWILA, WA 98188 PHONE: 206-575-4404 APPLICABLE CODES : NFPA 70 2011 NFPA 72 2010 INTERNATIONAL FIRE CODE 2009 INTERNATIONAL BUILDING CODE 2009 SCOPE OF WORK: COLO 3: DEMO AND REPLACE EXISTING HIGH SENSITIVITY SMOKE DETECTOR (HSSD) WITH NEW HSSD TO PROTGTL THREE (3) NEW CRAH UNITS. THE EXISTING MULTI ZONE POWER SUPPLY SHALL BE REUSED TO POWER NEW HSSD. THE POWER SUPPLY BATTERY CALCULATION SHALL BE COMPLETED AT TIME OF AS -BUILT. 24 HRS STANDBY AND 5 MINS ALARM SHALL BE PROVIDED. COLO 4: DEMO AND REPLACE TWO (2) HSSD'S WITH NEW HSSD'S TO PROTECT ELEVEN (11) NEW CRAH UNITS. THE EXISTING MULTI ZONE POWER SUPPLY SHALL BE REUSED TO POWER NEW HSSD'S. THE POWER SUPPLY BATTERY CALCULATION SHALL BE COMPLETED AT TIME OF AS -BUILT. 24 HRS STANDBY AND 5 MINS ALARM SHALL BE PROVIDED. ALL NEW SLC DEVICES SHALL BE TIED INTO EXISTING NET 8000 FIRE ALARM CONTROL PANEL AT CLOSEST SLC LOOP AND ADDRESSES SHALL BE PROVIDED AT TIME OF AS -BUILT. LEGEND / PARTS LIST SYMBOL QUAN. PART # DESCRIPTION MANUFACTURER NOTES OTHERWISE 3 VEP -A10 -P FOUR PIPE ASPIRATING SMOKE DETECTOR XTRALIS FOUR PIPE HSSD i 28 70-417008-001 ADDRESSABLE MONITOR MODULE (N/O) KIDDE 4S BOX OR 2 GANG Al 2 EXISTING MULTI ZONE POWER SUPPLY ANALASER PSX-X 2 EXISTING BATTERY CABINET EXISTING BATT 4 EXISTING BATTERIES EXISTING POWER SUPPLY 48 VP -P-210 3/4" CPVC PIPE, 15' LENGTH XTRALIS 345' TOTAL 38 VP-ELB-90 3/4" ELBOW, 90° XTRALIS 14 VP -TEE 3/4" TEE XTRALIS 30 VP -COUP 3/4" COUPLING XTRALIS 19 VP -EC 3/4" END CAP XTRALIS .‘• O Without Comments El As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau I'or conformance with current City .>tandards. Acceptance is subject to eii—o's and omissions which do not. authorize violations of adopted :,canards and ordariz-Inces, The r'esponsibiliq for the adequacy of destc. o rests totally with the designer. Additions, deIe ions ur revisions to these drawings after this date will void this !Je eptance and will require a resubmittal of rev. d c.rNdings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau, Date: /e)- "12 -19 By: I^^ $ t l �1154-101441‘0`-, Sial I co.�5/ wf Nr -PA 7)-, 5e,4'-. 17.7.'•(P Fire Permit Number To schedule inspections call 206-575-4407 LOCATION OF WORK trt o 17 Go VICINITY MAP SCALE: NTS AREA OF WORK .r ae Y..Pli:cr: inv:str;q.'. Map data ©2019 Google 500 ft t (.g& AREA MAP SCALE: NTS Imagery ©2019 Google, Map data ©2019 100 ft z.... SUPRESSION SYSTEMS INC. SPECIAL HAZARDS FIRE PROTECTION 3077 20TH STREET EAST, SUITE B FIFE, WA 98424-1798 " (253) 926-3300 FAX (253)926-3306 NATHAN SCHERNECK NICET #111032 - LEVEL 4, FIRE ALARM MANUFACTURER LOGO'S FIRE PROTECTION ENGINEERS STAMP e COMPLIANCE SUBMITTALS DATE 100% SUBMITTAL 09/10/19 COMMENTS 09/19/19 ‘JOB NUMBER:1938 OTHERWISE tREV DESCRIPTION DATE 1 AREVIEW COMMENTS 09/19/19 ‘JOB NUMBER:1938 OTHERWISE A i PROJECT INFORMATION: COLO 3 & 4 GE -04 PHASE 3433 SOUTH 120TH PLACE co T 0) Z 0 0 z_ F - DESIGNED BY:NMR SCALE: DRAWN BY: JAC NOT O SCALE CHECKED BY: ZST UNLESS NOTED ‘JOB NUMBER:1938 OTHERWISE SHEET TITLE: FIRE ALARM SYSTEM NOTES, LEGEND, PARTS LIST, MAPS, AND DRAWING INDEX SHEET NUMBER: FP -1.1 of 6 SUPRESSION SYSTEMS INC. SPECIAL HAZARDS FIRE PROTECTION 3077 20TH STREET EAST, SUITE B FIFE, WA 98424-1798 IM (253) 926-3300 FAX (253)926-3306 NATHAN SCHERNECK NICET #111032 - LEVEL 4, FIRE ALARM MANUFACTURER LOGO'S VES FIRE PROTECTION ENGINEERS STAMP COMPLIANCE SUBMITTALS DATE 100% SUBMITTAL 09/10/19 ....... AI Monitor Module Al Monitor Module '� t Power A Power Out B Power In VESDAnet C VESDAnet B D VESDAnet A VESDAnet E 1 - Isolate F 2 - Minor Fault G 3 - Urgent Fault H 4 - Alert 5 - Action J 6 - Fire 1 K 7 - Fire 2 Communications L USB M Ethernet GPI N Monitored GPI 0 Unmonitored GPI VESDAnet LOOP ♦ SH SH SH FrSLC FROM PREVIOUS DEV;CE DETECTOR 1 FACTORY DEFAULT (STANDALONE) SH DETECTOR 2 24 VDC IN FROM f+ POWER SUPPLY - 24 VDC OUT+ IF REQUIRED - J 0 Z 0 T. • `°Z 0 Z 0 I 0 `' too Z • M EOL EOL EOL I■I Al Monitory ....... AI Monitor Module Al Monitor Module '� � I■I ym W m (0 I■I N< N< . I■I ®— 01,--. 2` aV a RE M a%NII M 11:11.— — I vaT- - ED II�� 2E' VESDAnet LOOP ♦ SH SH SH FrSLC FROM PREVIOUS DEV;CE DETECTOR 1 FACTORY DEFAULT (STANDALONE) SH DETECTOR 2 24 VDC IN FROM f+ POWER SUPPLY - 24 VDC OUT+ IF REQUIRED - J 0 Z 0 T. • `°Z 0 Z 0 I 0 `' too Z • M EOL EOL EOL SLC TO NEXT DEVICE C CIO VEP -Al O -P k-±11 VESDA VEP -Al O -P DETECTOR MULTI LINE WIRING CADDY FASTENERS CATALOG # SIZE 166M 14-2 - 12-3 MC/AC TO 1" 16812M 1/2" OR 3/4" TO 1" 1616M 1620 1624M 1632M AIR SAM P PIPE NOTE: AIR SAMPLING PIPE MUST BE SUPPORTED EVERY 5 ft. 1" TO 1" 1 1/4" TO 1" 1 1/2" TO 1" 2" TO 1" LING ,*41%• 1" ROUND wiii,„ PEDESTAL CADDY FASTENERS CATALOG # 8P8P 8P12P 8P16P 12P12P 12P16P 16P16P AIR SAMPLING PIPE SIZE 1/2" TO 1/2" 1/2" TO 3/4" 1/2" TO 1" 3/4" TO 3/4" 3/4 TO 1" 1"TO 1" 1" SQUARE PEDESTAL RETURN AIR GRILL SELF TAPING SCREW STANDOFF POST 4" TO 8" LONG AIR SAMPLING PIPE SAMPLING PORT TO ANGLED TO OBTAIN BEST AIR SAMPLE RETURN AIR GRILL SHALL BE PROTECTED AT 4 SQ. FT. PER SAMPLING PORT. PIPE SHALL BE EXTENDED BEYOND EDGE OF GRILL AND A SOLID END CAP USED. NOTE: AIR SAMPLING PIPE MUST BE SUPPORTED EVERY 5 ft. AIR SAMPLING PIPE SUB -FLOOR HANGER DETAIL RETURN AIR GRILL STANDOFF POST DETAIL TO DEDICATED 120VAC AS NEEDED }24 VDC OUT HOTO NEUTO GNDO I I LOAD 2-1 + LOAD 1 O BATT 1‘ BATT 2 TROUBLE 4 NC RELAY C COM }24 VDC OUT SLC IN FROM PREVIOUS DEVICE 12V 12V + - 12V + 12V ''� Al Monitory ‘A,r AI Monitor Module 1■1 ;. I■I I■1 ym . I■1 I■I N< L. �- N< 2` a a 2 � C) Iujir. M 11:11.— I 2 ^ N IQ�■11 {�� II�� 2E' aT-'- `� 2." SLC TO NEXT DEVICE C CIO VEP -Al O -P k-±11 VESDA VEP -Al O -P DETECTOR MULTI LINE WIRING CADDY FASTENERS CATALOG # SIZE 166M 14-2 - 12-3 MC/AC TO 1" 16812M 1/2" OR 3/4" TO 1" 1616M 1620 1624M 1632M AIR SAM P PIPE NOTE: AIR SAMPLING PIPE MUST BE SUPPORTED EVERY 5 ft. 1" TO 1" 1 1/4" TO 1" 1 1/2" TO 1" 2" TO 1" LING ,*41%• 1" ROUND wiii,„ PEDESTAL CADDY FASTENERS CATALOG # 8P8P 8P12P 8P16P 12P12P 12P16P 16P16P AIR SAMPLING PIPE SIZE 1/2" TO 1/2" 1/2" TO 3/4" 1/2" TO 1" 3/4" TO 3/4" 3/4 TO 1" 1"TO 1" 1" SQUARE PEDESTAL RETURN AIR GRILL SELF TAPING SCREW STANDOFF POST 4" TO 8" LONG AIR SAMPLING PIPE SAMPLING PORT TO ANGLED TO OBTAIN BEST AIR SAMPLE RETURN AIR GRILL SHALL BE PROTECTED AT 4 SQ. FT. PER SAMPLING PORT. PIPE SHALL BE EXTENDED BEYOND EDGE OF GRILL AND A SOLID END CAP USED. NOTE: AIR SAMPLING PIPE MUST BE SUPPORTED EVERY 5 ft. AIR SAMPLING PIPE SUB -FLOOR HANGER DETAIL RETURN AIR GRILL STANDOFF POST DETAIL TO DEDICATED 120VAC AS NEEDED }24 VDC OUT HOTO NEUTO GNDO I I LOAD 2-1 + LOAD 1 O BATT 1‘ BATT 2 TROUBLE 4 NC RELAY C COM }24 VDC OUT SLC IN FROM PREVIOUS DEVICE 12V 12V + - 12V + 12V ''� Al Monitory ‘A,r m 1■1 'T. 'T. n I■1 ,,m (O In I■I Al Monitor 2 3 N< . 1 a Module 2� `1. M 11:11.— I ., ! M II�� =I aT-'- 2." N I ■ 1 •I INI O— I 1 (4-)T.- - A ♦ SLC TO NEXT DEVICE C CIO VEP -Al O -P k-±11 VESDA VEP -Al O -P DETECTOR MULTI LINE WIRING CADDY FASTENERS CATALOG # SIZE 166M 14-2 - 12-3 MC/AC TO 1" 16812M 1/2" OR 3/4" TO 1" 1616M 1620 1624M 1632M AIR SAM P PIPE NOTE: AIR SAMPLING PIPE MUST BE SUPPORTED EVERY 5 ft. 1" TO 1" 1 1/4" TO 1" 1 1/2" TO 1" 2" TO 1" LING ,*41%• 1" ROUND wiii,„ PEDESTAL CADDY FASTENERS CATALOG # 8P8P 8P12P 8P16P 12P12P 12P16P 16P16P AIR SAMPLING PIPE SIZE 1/2" TO 1/2" 1/2" TO 3/4" 1/2" TO 1" 3/4" TO 3/4" 3/4 TO 1" 1"TO 1" 1" SQUARE PEDESTAL RETURN AIR GRILL SELF TAPING SCREW STANDOFF POST 4" TO 8" LONG AIR SAMPLING PIPE SAMPLING PORT TO ANGLED TO OBTAIN BEST AIR SAMPLE RETURN AIR GRILL SHALL BE PROTECTED AT 4 SQ. FT. PER SAMPLING PORT. PIPE SHALL BE EXTENDED BEYOND EDGE OF GRILL AND A SOLID END CAP USED. NOTE: AIR SAMPLING PIPE MUST BE SUPPORTED EVERY 5 ft. AIR SAMPLING PIPE SUB -FLOOR HANGER DETAIL RETURN AIR GRILL STANDOFF POST DETAIL TO DEDICATED 120VAC AS NEEDED }24 VDC OUT HOTO NEUTO GNDO I I LOAD 2-1 + LOAD 1 O BATT 1‘ BATT 2 TROUBLE 4 NC RELAY C COM }24 VDC OUT SLC IN FROM PREVIOUS DEVICE 12V 12V + - 12V + 12V ''� Al Monitory '''T.CO Al Monitor Module MI 1■I 'T. 'T. N. Nm (0 I■I m I■I I 2 3 1111 Module . a III �l 2E M 11:11.— I ., N 11:1}•-- I■1 INI =I aT-'- X j SLC TO NEXT DEVICE C CIO VEP -Al O -P k-±11 VESDA VEP -Al O -P DETECTOR MULTI LINE WIRING CADDY FASTENERS CATALOG # SIZE 166M 14-2 - 12-3 MC/AC TO 1" 16812M 1/2" OR 3/4" TO 1" 1616M 1620 1624M 1632M AIR SAM P PIPE NOTE: AIR SAMPLING PIPE MUST BE SUPPORTED EVERY 5 ft. 1" TO 1" 1 1/4" TO 1" 1 1/2" TO 1" 2" TO 1" LING ,*41%• 1" ROUND wiii,„ PEDESTAL CADDY FASTENERS CATALOG # 8P8P 8P12P 8P16P 12P12P 12P16P 16P16P AIR SAMPLING PIPE SIZE 1/2" TO 1/2" 1/2" TO 3/4" 1/2" TO 1" 3/4" TO 3/4" 3/4 TO 1" 1"TO 1" 1" SQUARE PEDESTAL RETURN AIR GRILL SELF TAPING SCREW STANDOFF POST 4" TO 8" LONG AIR SAMPLING PIPE SAMPLING PORT TO ANGLED TO OBTAIN BEST AIR SAMPLE RETURN AIR GRILL SHALL BE PROTECTED AT 4 SQ. FT. PER SAMPLING PORT. PIPE SHALL BE EXTENDED BEYOND EDGE OF GRILL AND A SOLID END CAP USED. NOTE: AIR SAMPLING PIPE MUST BE SUPPORTED EVERY 5 ft. AIR SAMPLING PIPE SUB -FLOOR HANGER DETAIL RETURN AIR GRILL STANDOFF POST DETAIL TO DEDICATED 120VAC AS NEEDED }24 VDC OUT HOTO NEUTO GNDO I I LOAD 2-1 + LOAD 1 O BATT 1‘ BATT 2 TROUBLE 4 NC RELAY C COM }24 VDC OUT SLC IN FROM PREVIOUS DEVICE 12V 12V + - 12V + 12V SLC OUT TO NEXT DEVICE • • I r • • • ANALASER POWER SUPPLY WIRING DETAIL ''� c 1■1 PIPE 3 Al Monitor Module T' . IIlli rrn L203 Nm m 1■I Al Monitor 3 Inlet 1 or 4 Na . INI 4 ° - 2-., X 11:11.— Module a a 11:1}•-- X !) HSSD TROUBLE X j N INI O— I 1 U Q- s - SLC OUT TO NEXT DEVICE • • I r • • • ANALASER POWER SUPPLY WIRING DETAIL 00 — SLC FROM PREVIOUS — DEVICE OR FACP SLC TO NEXT DEVICE OR FACP ADDRESSABLE MONITOR MODULE WIRING DETAIL NO. OF PIPES PREFERRED PIPE INLET PORT TO USE PIPE 1 - PIPE 3 Al Monitor Module W v I 1 rrn L203 N. ()m co _ I 3 Inlet 1 or 4 c)Q 0 Int 4 ° - X ` a co X HSSD TROUBLE X o a N X I 1 Q- T - 1/4 00 — SLC FROM PREVIOUS — DEVICE OR FACP SLC TO NEXT DEVICE OR FACP ADDRESSABLE MONITOR MODULE WIRING DETAIL NO. OF PIPES PREFERRED PIPE INLET PORT TO USE PIPE 1 PIPE 2 PIPE 3 PIPE 4 1 Inlet 2 or 3 Inlet 2 or 3 2 X GROUND FAULT 3 Inlet 1 or 4 iV 4% Inlet 1 or 4 4 X MISSING DEVICE e 0 1 2 3 4 NOTE: DO NOT GLUE THE INLET PIPES TO THE PIPE INLET MANIFOLD. WHEN CONFIGURING THE DETECTOR ENSURE THAT THE CORRECT PIPES IN USE ARE SELECTED. VESDA VEP PIPE INLET PORT NUMBERING a. SEQUENCE OF OPERATIONS I- MATRIX FOR HSSD AIR O 2 SAMPLING DETECTION O w co co SYSTEM INPUTS SEND ALARM SIGNAL TO BUILDING FIRE ALARM CONTROL PANEL SEND TROUBLE SIGNAL TO BUILDING FIRE ALARM CONTROL PANEL AREVIEW COMMENTS SYSTEM TROUBLE A\ X BATTERY FAULT X GROUND FAULT X OPEN CIRCUIT FAULT X LOSS OF PRIMARY POWER X MISSING DEVICE X DUCT DETECTOR SMOKE MONITOR X HSSD TROUBLE X HSSD FIRE 1 X /REV DESCRIPTION DATE N AREVIEW COMMENTS 09/19/19 A\ A A PROJECT INFORMATION: GE -04 PHASE 1 COLO 3& 4 3433 SOUTH 120TH PLACE co (4 0) z 0 0 z_ Q H DESIGNED BY:NMR DRAWN BY: JAC CHECKED BY: ZST JOB NUMBER: 1938 SCALE: NOT TO SCALE UNLESS NOTED OTHERWISE SHEET TITLE: FIRE ALARM SYSTEM DETAILS AND SEQUENCE OF OPERATION [SHEET NUMBER: FP -1.2 of 6 1 SUPRESSION SYSTEMS INC. SPECIAL HAZARDS FIRE PROTECTION 3077 20TH STREET EAST, SUITE B FIFE, WA 98424-1798 IM (253) 926-3300 FAX (253)926-3306 NATHAN SCHERNECK NICET #111032 - LEVEL 4, FIRE ALARM MANUFACTURER LOGO'S VE52 FIRE PROTECTION ENGINEERS STAMP COMPLIANCE SUBMITTALS DATE DATE 1 100% SUBMITTAL 09/1 0/1 9 1 A\ 147A F ER TERM ,OEC' COLO 143 145A 188 14 D w J CO 0 b OPSI OSTOMER WORK ARE 148 EXISTING POWER SUPPLY FOR COLO 3 HSSD EXISTING POWER SUPPLY FOR COLO 4 HSSDS - J 47B FIBER TERM. LSC B DC ATB 45B CONTROLS PLAN SCALE: 1 /8"=1'-0" EC X -XXX (FIRE 1) I Al \HSSDI A X -XXX (TROUBLE) Al Al Al Al Al Al AI Al 142 Al Al X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY C O4 144 AI X -XXX (TROUBLE) HSSDI Al 1 X -XXX (FIRE 1) F_, C NOTE: ALL DEVICES SHALL BE ADDRESSED AT TIME OF AS -BUILT. - TIE INTO NEAREST SLC LOOP XXX Al XXX 1 \r HSSD A FIRE 1 COLO 4 XXX Al Al XXX 1 HSSD A TROUBLE COLO 4 XXX 1 .r DUCT DETECTOR Al Al XXX 1 HSSD B FIRE 1 COLO 4 XXX 1 r DUCT DETECTOR Al Al XXX 1 .r Al XXX 1 HSSD B HSSD C TROUBLE FIRE 1 COLO4 COLO3 XXX 1 •r DUCT DETECTOR Al XXX 1 DUCT DETECTOR Al Al XXX 1 Al XXX 1 Al 1 HSSD C DUCT DUCT TROUBLE DETECTOR DETECTOR COLO 3 SUP. SUP. XXX 1 Al XXX 1 Al XXX 1 •r DUCT DUCT DUCT DETECTOR DETECTOR DETECTOR SUP. SUP. SUP. SUP. SUP. SUP. SUP. XXX Al XXX 1 DUCT DETECTOR SUP. SUP. SUP. SUP. Al XXX 1 DUCT DETECTOR Al XXX 1 Al XXX 1 DUCT DUCT DETECTOR DETECTOR Al XXX 1 COLO 3 PS 1-X TROUBLE Al 1 \r COLO 4 PS2-X TROUBLE SINGLE LINE WIRING SCALE: NTS Al 1 DUCT DETECTOR SUP. C TIE INTO NEAREST SLC LOOP GRAPHIC SCALE 0 2 4 8 16 24 32 "REV DESCRIPTION DATE 1 AREVIEW COMMENTS I 1 A\ A. J CONTROLS PLAN SCALE: 1 /8"=1'-0" EC X -XXX (FIRE 1) I Al \HSSDI A X -XXX (TROUBLE) Al Al Al Al Al Al AI Al 142 Al Al X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY X -XXX DUCT DETECTOR SUPERVISORY C O4 144 AI X -XXX (TROUBLE) HSSDI Al 1 X -XXX (FIRE 1) F_, C NOTE: ALL DEVICES SHALL BE ADDRESSED AT TIME OF AS -BUILT. - TIE INTO NEAREST SLC LOOP XXX Al XXX 1 \r HSSD A FIRE 1 COLO 4 XXX Al Al XXX 1 HSSD A TROUBLE COLO 4 XXX 1 .r DUCT DETECTOR Al Al XXX 1 HSSD B FIRE 1 COLO 4 XXX 1 r DUCT DETECTOR Al Al XXX 1 .r Al XXX 1 HSSD B HSSD C TROUBLE FIRE 1 COLO4 COLO3 XXX 1 •r DUCT DETECTOR Al XXX 1 DUCT DETECTOR Al Al XXX 1 Al XXX 1 Al 1 HSSD C DUCT DUCT TROUBLE DETECTOR DETECTOR COLO 3 SUP. SUP. XXX 1 Al XXX 1 Al XXX 1 •r DUCT DUCT DUCT DETECTOR DETECTOR DETECTOR SUP. SUP. SUP. SUP. SUP. SUP. SUP. XXX Al XXX 1 DUCT DETECTOR SUP. SUP. SUP. SUP. Al XXX 1 DUCT DETECTOR Al XXX 1 Al XXX 1 DUCT DUCT DETECTOR DETECTOR Al XXX 1 COLO 3 PS 1-X TROUBLE Al 1 \r COLO 4 PS2-X TROUBLE SINGLE LINE WIRING SCALE: NTS Al 1 DUCT DETECTOR SUP. C TIE INTO NEAREST SLC LOOP GRAPHIC SCALE 0 2 4 8 16 24 32 "REV DESCRIPTION DATE 1 AREVIEW COMMENTS 09/19/19 1 A\ A. J J PROJECT INFORMATION: GE -04 PHASE 1 COLO 3 & 4 3433 SOUTH 120TH PLACE co (0 W 0) Z 0 1- 0 0 Z DESIGNED BY:NMR SCALE: NOT TO SCALE UNLESS NOTED OTHERWISE, DRAWN BY: JAC CHECKED BY: ZST JOB NUMBER: 1938 SHEET TITLE: FIRE ALARM SYSTEM CONTROLS PLAN SHEET NUMBER: FP -2.1 of 6 o FUTURE FUTURE FUTURE FUTURE FUTURE FUTURE FUTURE FUTURE A A 143 � JICUSTO IER WORK A. 148 47B R FF M CLOSET E3 144 HSSD PIPING PLAN SCALE: 1 /8"=1'-0" GRAPHIC SCALE 0 2 4 8 16 24 32 1 SUPL ESSION SYSTEMS INC. SPECIAL HAZARDS FIRE PROTECTION 3077 20TH STREET EAST, SUITE B FIFE, WA 98424-1798 PA (253) 926-3300 FAX (253)926-3306 1, NATHAN SCHERNECK NICET #111032 - LEVEL 4, FIRE ALARM MANUFACTURER LOGO'S VES3 FIRE PROTECTION ENGINEERS STAMP COMPLIANCE SUBMITTALS DATE DATE 100% SUBMITTAL 09/1 0/1 9 A\ A A 'REV DESCRIPTION DATE A REVIEW COMMENTS 09/19/19 A\ A A 4 1 PROJECT INFORMATION: IGE-04 PHASE 1 COLO 3 & 4 3433 SOUTH 120TH PLACE co CU TM W 0) z 0 z s DESIGNED BY:NMR DRAWN BY: JAC CHECKED BY: ZST JOB NUMBER: 1938 SCALE: NOT TO SCALE UNLESS NOTED OTHERWISE SHEET TITLE: FIRE ALARM SYSTEM HSSD PIPING PLAN [SHEET NUMBER: FP -2.2 of 6 SOLID ENDCAP TYP N0 0'-6" TYP 1t- / ,561=9 / 15'-0" TYP 0 0 '" COLO 4 EAST DETECTOR C 2'-2" TYP / 5'-0" / 5'-6" /c). .,,c�, NOTE: ALL PIPE TO BE 3/4" O UNLESS OTHERWISE STATED 13'-6" 1 6'-3" 0'-6" / / / / / / — TEST POINT 5'-0" ARF SOLID ENDCAP X:X-10 X:X-6 X:X-7 X:X-5 / / / X:X-1 X:X-2 3/4" X 1'-0" X:X-3 3/4" X 1'-0" X:X-4 3/4" X 1'-0" 3/4" X 1 '-0" 3/4" X 1'-0" 3/4" X 1'-0" X:X-8 3/4" X 1'-0" X:X-9 3/4" X 1'-0" 3/4" X 1'-0" EXTEND TO EDGE OF UNIT SOLID END CAP TYPICAL EAST UNITS / / COLO 3 EAST DETECTOR SAMPLING HOLE # HOLE DIA. (INCH) SAMPLING HOLE # HOLE DIA. (INCH) 1:1-1 5/64 1:3-1 5/64 1:1-2 5/64 1:3-2 5/64 1:1-3 5/64 1:3-3 5/64 1:1-4 5/64 1:3-4 5/64 1:1-5 5/64 1:3-5 5/64 1:1-6 5/64 1:3-6 5/64 1:1-7 5/64 1:3-7 5/64 1:1-8 5/64 1:3-8 5/64 1:1-9 5/64 1:3-9 5/64 1:1-10 5/64 1:3-10 5/64 1:2-1 5/64 1:2-2 5/64 1:2-3 5/64 1:2-4 5/64 1:2-5 5/64 1:2-6 5/64 1:2-7 5/64 1:2-8 5/64 1:2-9 5/64 1:2-10 5/64 SYSTEM CALCULATIONS: CRAH 21-8.75" X 10'-3"= 28 SQ. FT. 28 SQ. FT / 4 SQ. FT. = 7 SAMPLING POINTS 7 X 3 CRAHS = 21 SAMPLING POINTS 30 SAMPLING POINTS PROVIDED. SYSTEM RESULTS: CALCULATED TRANSPORT TIME = 26 SEC CALCULATED SYSTEM FLOW = 79.3 L/MIN MINIMUM AGGREGATE SENSITIVITY = 0.0016% OB/FT MAXIMUM AGGREGATE SENSITIVITY = 0.1465% OB/FT SUPRESSION SYSTEMS INC. SPECIAL HAZARDS FIRE PROTECTION 3077 20TH STREET EAST, SUITE B FIFE, WA 98424-1798 IN (253) 926-3300 FAX (253)926-3306 NATHAN SCHERNECK NICET #111032 - LEVEL 4, FIRE ALARM MANUFACTURER LOGO'S VE5B FIRE PROTECTION ENGINEERS STAMP • COMPLIANCE SUBMITTALS DATE 1 00% SUBMITTAL 09/10/19 COMMENTS 09/19/19 t OTHERWISE 'REV DESCRIPTION DATE 1 AREVIEW COMMENTS 09/19/19 A\ OTHERWISE A d PROJECT INFORMATION: GE -04 PHASE 1 COLO 3 & 4 3433 SOUTH 120TH PLACE co (0 T co 0) z 0 1- 0 z 1 cn Q D I - DESIGNED BY:NMR SCALE: DRAWN BY: JAC NOT TO SCALE CHECKED BY: ZST UNLESS NOTED JOB NUMBER: 1938 OTHERWISE SHEET TITLE: FIRE ALARM SYSTEM HSSD PIPING PLAN COLO 3 N. 1 SHEET NUMBER: FP -2.3 of 6 1 COLO 4 WEST DETECTOR A / 6 UNITS SAMPLING HOLE # HOLE DIA. (INCH) SAMPLING HOLE # HOLE DIA. (INCH) SAMPLING HOLE # HOLE DIA. (INCH) 1:1-1 5/64 1:3-1 5/64 2:2-1 5/64 1:1-2 5/64 1:3-2 5/64 2:2-2 5/64 1:1-3 5/64 1:3-3 5/64 2:2-3 5/64 1:1-4 5/64 1:3-4 5/64 2:2-4 5/64 1:1-5 5/64 1:3-5 5/64 2:2-5 5/64 1:1-6 5/64 1:3-6 5/64 2:2-6 5/64 1:1-7 5/64 1:3-7 5/64 2:2-7 5/64 1:1-8 5/64 1:3-8 5/64 2:2-8 5/64 1:1-9 5/64 1:3-9 5/64 2:2-9 5/64 1:1-10 5/64 1:3-10 5/64 2:2-10 5/64 1:2-1 5/64 2:1-1 5/64 2:3-1 5/64 1:2-2 5/64 2:1-2 5/64 2:3-2 5/64 1:2-3 5/64 2:1-3 5/64 2:3-3 5/64 1:2-4 5/64 2:1-4 5/64 2:3-4 5/64 1:2-5 5/64 2:1-5 5/64 2:3-5 5/64 1:2-6 5/64 2:1-6 5/64 2:3-6 5/64 1:2-7 5/64 2:1-7 5/64 2:3-7 5/64 1:2-8 5/64 2:1-8 5/64 2:3-8 5/64 1:2-9 5/64 2:1-9 5/64 2:3-9 5/64 1:2-10 5/64 2:1-10 5/64 2:3-10 5/64 SYSTEM CALCULATIONS: CRAH 3'-11" X 10'-2"= 40 SQ. FT. 40 SQ. FT / 4 SQ. FT. = 10 SAMPLING POINTS 10 X 6 CRAHS = 60 SAMPLING POINTS 60 SAMPLING POINTS PROVIDED. SYSTEM RESULTS: CALCULATED TRANSPORT TIME = 37 SEC CALCULATED SYSTEM FLOW = 109.0 L /MIN MINIMUM AGGREGATE SENSITIVITY = 0.0398% OB / FT MAXIMUM AGGREGATE SENSITIVITY = 0.2273% OB / FT SOLID ENDCAP TYP 0 0'-6" TYP TYr, 0 X:X-1 X:X-5 X:X-4 X:X-10 X:X-9 EXTEND TO EDGE OF UNIT SOLID END CAP 3/4" X 1'-0" X:X-8 3/4" X 1'-0" X:X-7 3/4" X 1'-0" X:X-6 3/4" X 1'-0" 3/4" X 1'-0" 3/4" X 1'-0" X:X-3 3/4" X 1'-0" X:X-2 3/4" X 1'-0" 3/4" X 1'-0" 0 TYPICAL WEST UNITS SOLID ENDCAP TYP NO 2:, 0'-6" TYP 15'-0" TY 0 / 2-2" TYP - TEST POINT 5'-0" ARF 16'-3" / 2'-2" TYP 51 4" / / OOH 54ar 10'-1" 13'-6" �- COLO 4 EAST DETECTOR B NOTE: ALL PIPE TO BE 3/4" 0 UNLESS OTHERWISE STATED 4' 10" 10'-3" 51-0" SOLID ENDCAP 0'-6" 49'-7" 14'-9" 0'-6" NOTE: ALL PIPE TO BE 3/4" 0 UNLESS OTHERWISE STATED COLO 4 WEST DETECTOR Ai 0'-6" TYP SOLID ENDCAP TY 0 15'-0" TYP 4'-10" 2-2" TYP 0 14'-4" SOLID ENDCAP TY j 0'-6" SOLID ENDCAP 15'-0" TY j EST POINT 5'-0" ARF / 2'-2" TYP - TEST POINT 5'-0" ARF / / TEST POINT 5'-0" ARF SOLID ENDCAP 01-6" SOLID ENDCAP X:X-10 X:X-6 X:X-7 X:X-1 X:X-2 3/4" X 1'-0" X:X-3 3/4" X 1'-0" X:X-4 3/4" X 1'-0" X:X-5 3/4" X 1'-0" 3/4" X 1'-0" 3/4" X 1'-0" X:X-8 3/4" X 1'-0" X:X-9 3/4" X V-0" 3/4" X 1'-O" EXTEND TO EDGE OF UNIT SOLID END CAP TYPICAL EAST UNITS 14'-10" 50'-0" COLO 4 EAST DETECTOR B / 5 UNITS SAMPLING HOLE # HOLE DIA. (INCH) SAMPLING HOLE # HOLE DIA. (INCH) SAMPLING HOLE # HOLE DIA. (INCH) 1:1-1 5/64 1:3-1 5/64 2:2-1 5/64 1:1-2 5/64 1:3-2 5/64 2:2-2 5/64 1:1-3 5/64 1:3-3 5/64 2:2-3 5/64 1:1-4 5/64 1:3-4 5/64 2:2-4 5/64 1:1-5 5/64 1:3-5 5/64 2:2-5 5/64 1:1-6 5/64 1:3-6 5/64 2:2-6 5/64 1:1-7 5/64 1:3-7 5/64 2:2-7 5/64 1:1-8 5/64 1:3-8 5/64 2:2-8 5/64 1:1-9 5/64 1:3-9 5/64 2:2-9 5/64 1:1-10 5/64 1:3-10 5/64 2:2-10 5/64 1:2-1 5/64 2:1-1 5/64 1:2-2 5/64 2:1-2 5/64 1:2-3 5/64 2:1-3 5/64 1:2-4 5/64 2:1-4 5/64 1:2-5 5/64 2:1-5 5/64 1:2-6 5/64 2:1-6 5/64 1:2-7 5/64 2:1-7 5/64 1:2-8 5/64 2:1-8 5/64 1:2-9 5/64 2:1-9 5/64 1:2-10 5/64 2:1-10 5/64 SYSTEM CALCULATIONS: CRAH 3'-11" X 10'-2"= 40 SQ. FT. 40 SQ. FT / 4 SQ. FT. = 10 SAMPLING POINTS 10 X 5 CRAHS = 50 SAMPLING POINTS 50 SAMPLING POINTS PROVIDED. SYSTEM RESULTS: CALCULATED TRANSPORT TIME = 46 SEC CALCULATED SYSTEM FLOW = 113.4 L/MIN MINIMUM AGGREGATE SENSITIVITY = 0.0016% OB/FT MAXIMUM AGGREGATE SENSITIVITY = 0.1465% OB/FT 1 t SUPFESSION SYSTEMS INC. SPECIAL HAZARDS FIRE PROTECTION 3077 20TH STREET EAST, SUITE B FIFE, WA 98424-1798 TM (253) 926-3300 FAX (253)926-3306 NICET STAMPS ,e.zz CERTIFIED NATHAN SCHERNECK NICET #111032 - LEVEL 4, FIRE ALARM MANUFACTURER LOGO'S VESB FIRE PROTECTION ENGINEERS STAMP COMPLIANCE SUBMITTALS DATE 100% SUBMITTAL 09/10/19 COMMENTS 09/19/19 A JOB NUMBER: 1938 /REV DESCRIPTION DATE 1 AREVIEW COMMENTS 09/19/19 A JOB NUMBER: 1938 OTHERWISE n' 4 PROJECT INFORMATION: GE -04 PHASE 1 COLO 3& 4 3433 SOUTH 120TH PLACE co CO - 0 0 I- 0 z_ T H DESIGNED BY:NMR SCALE: DRAWN BY: JAC NOT TO SCALE CHECKED BY: ZST UNLESS NOTED JOB NUMBER: 1938 OTHERWISE SHEET TITLE: FIRE ALARM SYSTEM HSSD PIPING PLAN COLO 4 [SHEET NUMBER: FP -2.4 of 6 57'-112" 57'-112» CIRCUIT (TYP.) CANDELA (TYP.)— "4'30 3 30 DOCK SEC. 114 / - 1 3 15 TO KIOSK AREA 2 2–#14 TYP N N N CN TO KIOSK AREA 2 2–#14 TYP 1 ELECTRICAL ROOM MR 110 128 TO KIOSK AREA 2 2–#14 TYP Cap LEGE\3 3 15 3 15 , ,\ WALL MOUNT HORN/STROBE (NEW OR EXISTING) WITH WORK UNDER JOB# 08-1695 WALL MOUNT HORN/STROBE (EXISTING) NO WORK UNDER JOB# 08-1695 WALL STROBE (NEW OR EXISTING) WITH WORK UNDER JOB# 08-1695 WALL STROBE (NEW OR EXISTING) WITH WORK UNDER JOB# 08-1695. FLAG\ OTES: 1. RELOCATE THIS DEVICE EAST 18". 2. POINT OF CONNECTION TO ADD NEW NOTIFICATION APPLIANCES. PULL #4/14 TO NEW DEVICE TO RETAIN LOOP INTEGRITY. NO T—TAPPING NOTIFICATION APPLIANCE CIRCUITS. 3. INSTALL NEW STROBE HERE. \OTE: CHA\GES SHOW\ 0\ SHEETS FA` -7.1 A\D FA14.1 U\DEEVISIO\ C WEE DIVE\ 3Y DEFICIE\CI-S FOU\D 3Y CAPT. WALLED OF TU<WILA FD �0\ 3/5/09. /1 V ATE SIAL LIST ITEM SYM QTY PART NUMBER MODEL NUMBER DESCRIPTION MANUFACTURER MOUNTING 1 – 2 DSM -12/24 – DUAL SYNC MODULE WHEELOCK 4–S BOX 2 O\ 3 ZRS–MCW–FR – WALL MOUNT MULTICANDELA STROBE – RED WHEELOCK 4-11/16" X 2.125" BACK BOX E J�NOTIFICATION APPLIANCE CIRUITS PLAN SCALE: AREA 1� E3) CCEPTED .l thout Comments '>ote in Red _,.w Attached Lettetr .pl „ s have 1.; er The Tukwila Fire r;o eot7n f-tC 'vt ft i current City :Ut3 ..� to EI;Tor and /� p tvF'! `sl':h �3'+, t tt i. �2'�'..ti:i v =!Cuo..s of adopted `.rc i" r. 9�t':i Y .. . 1 iv` resp. n aythe ,..•,:t dJ and �'f � "-.14i: i.ir ��t(t.y! for ; th rc:e dezigner. •..; s < ;e :_'ir'`r`, eie 1,vi;;;.;_6ti Y,. Gfftei thin: acce'1 •iJDr S.F.L _i 641 tl`.;ii re"q;:irvi oi7.i-,:z i,?:•;'o draw _z subszciuent pDrovat. iat>c,.'.vtGiil.' is roi.;bti :.i. .•:t i:l-;.d teat and inspection by 7i -1e, Tukwila uk:` ila Fir,. Prevention Bureau. Date 10 -Ly c__ E'v: / 57 / I t1KWILA FIRE DEPARTMEM Please call: 575.4407 and give this job No. o- F- f,3 g and exact address for shut. gown or restoration approval; 0 0 0 0 0 0 AREA 2 AREA 3 O 0 0 KEY PLAN L AREA 4 0 0 0 0 0 0 0 0 0 DRAWN BY: JSL DATE: 10/02/09 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 2 FIRE ALARM REVISIONS TO EXISTING SYSTEM SHEET DESCRIPTION: LO rn co 0 w Q NOTIFICATION APPLIANCE CIRCUITS PLAN MICROSOFT TUKWILA 2 DATA CENTER w DESCRIPTION JOB NO.: 08-1695 FA7.1 DRAWING NO.: FA-07.1.dwg LEGS\ 57'-112" 57'-111" WALL MOUNT HORN/STROBE (EXISTING) NO WORK UNDER JOB# 08-1695 WALL STROBE (NEW OR EXISTING) WITH WORK UNDER JOB# 08-1695 15 a 15 4 CORRIDOR 15 105 5 FLAG\OYES: 2#14, TYP. 2#14, TYP. INSTALL TWO NEW EXTERNAL DSM DUAL SYNC MODULES. INTERCEPT ALL 4 OUTPUT CIRCUITS AND WIRE AS SHOWN IN DETAIL BELOW (2 CIRCUITS PER DSM). RESET SWITCHES IN EP1 TO "NO SYNC" AS EXISTING EQUIPMENT WILL NOW SYNC FROM THE NEWLY ,INSTALLED DSM MODULES. THIS BOOSTER PANEL HAS EXISTING EXTERNAL SYNC MODULES. INSTALL #2/16 WIRE FROM EXISTING SYNC MODULES TO NEW SYNC MODULES. SEE DETAIL BELOW. ACCEPTED FOR USE CITY OF NEW YORK DEPARTMENT OF BUILDINGS MEA 151-92-E VOL WHEELOCK. INC FIBER TERMINATION CLOSET B FIBER TERMINATION CLOSET A 110 ELO� SYNC WIRE FROM PREVIOUS DSM + SYNC WIRE TO NEXT DSM + REF. INST. SH T. OLISTED 2M14 SIGNALING APPLIANCE FOR THE HEARING IMPAIRED FROM BOOSTER PANEL CKT A CKT B DC PLANT A DC PLANT B 2#14, TYP. 2#14, TYP. 120V AC DEDICATED CIRCUIT BEAKER 3—#12 CORRIDOR 15 TO AREA 1 HORN/STROBE CIRCUITS 1,2,3 2—#14 EA. TYP. EXISTING AUDIBLE EXPANDER PANEL LOCATED INSIDE KIOSK CABINET, TYP. 2 PLCS. z O I -- Q z 0 U 0 LL N 1 Q LL LiJ LiJ - TO APPLIANCE + OR SYNC STROBE +OUT 1 --FIN 1 MINUS 1 +AUD -AUD OUT 2 -+IN 2 -MINUS DSM WI�I \G DIAG'AV2 INDICATES FULL HEIGHT WALLS NOTIFICATION APPLIANCE CIRCUITS PLAN \OTE: CHA\GES SHOWN ON SHEETS FA 7.1 A\D FA14.1 U\EVISIO\ C WEE DIVEN 3Y DEFICIE\CIES FOU\D 3Y CAPT. WALLED OF TU4WILA FD 0\ 3/5/09. c 0 0 0 0 © 0 1 0 0 AREA 1 AREA 2 AREA 3 AREA4 KEY PLAN 0 0 0 0 0 0 0 0 0 0 DRAWN BY: JSL DATE: 10/02/09 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 2 W ¢ a) 0 EE N N Lo �� t:O N PROJECT DESCRIPTION: FIRE ALARM REVISIONS TO EXISTING SYSTEM SHEET DESCRIPTION: 0) co a) 0 N W NOTIFICATION APPLIANCE CIRCUITS PLAN TUKWILA 2 DATA CENTER MICROSOFT W U a x h cYD 0 co co rn 0) O CO O LO 0) 00 0 CO0 0 w 0 (l) LU U 0 0 U 0 Go 0, 0 0 0 U W W 0 U 0 w W 0 DESCRIPTION U JOB NO.: 08-1695 DRAWING NO.: FA-14.1.dwg FA14.1 08-1690 v ATE SIAL LIST ITEM SYM QTY QTY PART NUMBER MODEL NUMBER DESCRIPTION MANUFACTURER MOUNTING FA -1.1 - DRAWING LIST, MATERIALS LIST, DETAILS - 08-1690 IR INFRARED • FA -3 2 CEILING DETECTOR LOCATION PLAN - AREA 1 1 FACP-X CEILING WIRING PLAN - AREA 1 2 - 74-200000-100 FN2000 MULTI LOOP WITH MOTHER BOARD FENWAL 72" AFF 2 - - - - - RELAY MODULE FENWAL IN FACP-1,2 3 - 2 - 74-200009-002 - POWER SUPPLY MODULE ONLY - 4 AMPS 36" HARNESS FENWAL IN FACP-1,2 4 - 8 - 74-200005-002 RXTX RXTX MODULE FENWAL IN FACP-1,2 5 - - - - - - - - 6 - - - - - - - - 7 - - - - - - - - 8 EC -X FA -23 1 - 74-200000-005 - EXPANSION ENCLOSURE FENWAL 72" AFF 9 - 1 - 74-200000-006 - EXPANSION BACKPLANE FENWAL - 10 - 1 - 74-200009-010 - POWER SUPPLY/CHARGER FENWAL - 11 - 1 - 74-200009-003 - POWER SUPPLY MODULE, 8" HARNESS FENWAL - 12 - 6 - 74-200001-001 - AGENT RELEASE IVODULE FENWAL IN FCP #2 13 FA -38 AL FIRE CONTROL PANEL MODULE DETAILS 12 - 73-100001-001 - ALAMLINE/FN2000 INTERFACE MOD. FENWAL - 14 HSSD DISPLAY, CONNECTION DETAIL, ZONE 1 ,2,& 3 3 - 73-117068-016 NYLON SENSOR 650' PER COIL, ALARMLINE LINEA THERMAL CABLE FENWAL - 15 - 1 - 74-100017-001 - BATTERY ENCLOSURE FOR EXTRA BATTERIES FENWAL BELOW FCP 16 - 4 - PS -12560 - BATTERY 12V, 50AH POWERSONIC IN BATTERY CABINET 17 1246 34 71-402001-100 PSD -7152 INTELLIGENT PHOTO DETECTOR FENWAL ON BASE 8 (, 0 - 0-404001 -100 H1- 2 2 N L IG N H R AL D T C 0' A ON BAS 19 - 1256 29 70-400001-100 6SB 6" UNIVERSAL DETECTOR BASE FENWAL 4-S BOX 20 GEN 170 - 70-407008-001 Al ADDRESSABLE CONTACT INPUT N.0. FENWAL 4-S BOX Al GALLONS PER MINUTE 21 ULTRAVIOLET GRC 44 1 70-408004-001 AO ADDRESSABLE RELAY OUTPUT FENWAL 4-S BOX HSSD AO VAC VOLTS ALTERNATING CURRENT HVAC HEATING, VENTILATION, & AIR CONP'TtONING 2 %._ —46_ HERTZ, CYCLES PER SECOND 0 - 0-40 001-1 2 RH-2001 DU T HOU I G PI -0 0 D E TOR A - INDICATING APPLIANCE CIRCUIT WP, W/P WEATHER PROOF ID IDENTIFICATION XFMR 23 — 10 — 06-129500-005 - 96 SAMPLING TUBE FENWAL - 24 25 - 29-320000-280 - MANUAL PULL DBL ACTION WITH F.A. LEGEND FENWAL 1 -GANG DEEP BOX 25 1 - 89-100055-001 - HSSD MODULAR POWER SUPPLY FENWAL IN KIOSK 26 ;o; 36 - 75-000085-001 NS -24110W -FR HORN/STROBE 110cd (FIRE) FENWAL 4-S BOX 27 \A 15 - 75-000005-001 RSS-24110W-FR 110cd STROBE (FIRE) UNIVERSAL MOUNT FENWAL 4-S BOX 28 \A 16 - 75-000005-001 RSS-241 5W -FR 15cd STROBE (FIRE) UNIVERSAL MOUNT FENWAL 4-S . BOX 29 ;o;a 7 - 75-000084-001 NS -2475W -FR HORN/STROBE 75cd (FIRE) FENWAL 4-S BOX 30 0,< 16 - 75-000083-001 NS -2430W -FR HORN/STROBE 30cd (FIRE) FENWAL 4-S BOX 31 ;o; 43 - 75-000081-001 NS -2415W -FR HORN/STROBE 15cd (FIRE) FENWAL- 4-S BOX 32 1 — 74-300000-501 RDCM REMOTE DISPLAY MODULE FENWAL 60" AFF FSA1 33 6 - 74-300000-502 RDM REMOTE DISPLAY CONTROL MODULE FENWAL IN KIOSK 34 - 4 - PS -12/24-8 - POWERPATH 8 AMP WHEELOCK IN KIOSK CABINETS 35 - 8 - PS -12120 - 12V, 12AH BATTERY POWERSONIC IN POWERPATH 36 3 - 89-100058-004 - HSSD 4 ZN. UNIT/POWER SUPPLY FENWAL IN KIOSK HSSD# 37 - 3 - 89-1000053-000 - HSSD 4 ZONE ENCLOSURE FENWAL IN KIOSK 38 11 - 89-100000-031 - MODULAR DETECTOR/FAN BOX 0.003 TO 0.03% FENWAL 72" AFF 39 - 6 - 89-100074-001 - ANALASER SAMPLING POINT LABEL ROLL OF 100 FENWAL - 40 - 6 - 89-100074-002 - ANALASER SAMPLING PORT LABEL ROLL OF 100 FENWAL - 41 - 6 - 89-100074-003 - ANALASER SAMPLING PIPE LABEL ROLL OF 100 FENWAL - 42 K1 6 - KIOSK -1 - MAIN KIOSK STATION CUSTOM - 43 K2 6 - KIOSK -2 — SECONDARY KIOSK STATION • CUSTOM - 44 R 23 — MR -101 — SHUT DOWN RELAY AIR PRODUCTS 1 LANG DEEP BOX 45 - 2 - 74-200036-001 - NETWORK INTERFACE CARD FENWAL IN FACP-1 & 2 46 6 - 70-200200-001 - ADDRESSABLE SIGNAL DEVICE MODULE FENWAL 4-S BOX SDM 47 - 12 - XX - MANUAL PULL STATION - SUPPRESSION FENWAL IN KIOSK 48 - 12 - XX - EMERGENCY POWER OFF SWITCH S.T.I. IN KIOSK 49 - 12 - XX - EPO MINI STOPPER COVER W/ HORN S.T.I. IN KIOSK 50 - 24 - MT -2415W -FR - VULTI-TONE HORN/STROBE WHEELOCK IN KIOSK 51 — 12 — — — 5# CO2 EXTINGUISHER - IN KIOSK 52 - 12 - VC -86-40 - FLOOR TILE PULLER - IN KIOSK 53 - 12 - 45117 - RECHARGABLE FLASHLIGHT STREAv1LIGHT IN KIOSK 54 - 12 - HC -2318R - EXTINGUISHER CABINET LARSON IN KIOSK 55 - - 1 AL4000LPD4 - 24VDC POWER SUPPLY FOR DOOR MAGS ALTRONIX 1 IN KIOSK 56 - - 4 FM -998-24 - DOOR MAGNETS NOTIFIER 2" x 4" x 1-3/4" - ELECTRICAL NOTES EACH FIRE PROTECTION CONTROL PANEL OR RELEASING PANEL SHALL BE FED FROM A DEDICATED CIRCUIT. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR LABELING ALL CIRCUITS THAT SERVE FIRE PROTECTION EQUIPMENT AT THE RESPECTIVE PANEL. LABELING SHALL BE RED. CIRCUITS THAT FEED FIRE PROTECTION EQUIPMENT SHALL BE MARKED AT THE EQUIPMENT SERVED AND MUST BE IDENTIFIED ON THE AS BUILT MARK UP OF THIS DRAWING. MARK INCOMING CABLES TO EACH DEVICE WITH BLACK TAPE. IDENTIFY THE CIRCUIT NUMBER AT ALL SPLICES & TERMINATIONS. ELECTRICAL CONDUIT AND WIRING SHALL CONFORM WITH THE NATIONAL ELECTRICAL CODE (NEC), STATE & LOCAL CODES. ALL FLOOR PENETRATIONS AND FIRE RATED WALL PENETRATIONS SHALL BE SEALED WITH APPROVED FIRE STOPPING COMPOUND. NOTIFICATION APPLIANCE CIRCUIT SHALL CONFORM TO CLASS B, STYLE Y REQUIREMENTS AS PER NFPA 72 CURRENT EDITION. SIGNALING LINE CIRCUIT (SLC) OR INITIATING DEVICE CIRCUIT (IDC) SHALL CONFORM TO CLASS B, STYLE 4 REQUIREMENTS AS PER NFPA 72 CURRENT ADDITION UNLESS OTHERWISE INDICATED ON THE DRAWINGS WHICH WOULD INDICATE CLASS A STYLE 6. SIGNALING LINE CIRCUIT (SLC) AND THE NOTIFICATION APPLIANCE CIRCUIT (NAC) WIRING SHOULD FOLLOW THE PATH SHOWN ON THE RISER DIAGRAM. ALL DEVIATION MUST BE DOCUMENTED ON THE AS BUILT. SIGNALING LINE CIRCUIT (SLC) WIRING OR INITIATING DEVICE CIRCUIT (IDC) WIRING SHALL BE FPL OR FPLP (AS SPECIFIED IN THE WIRE LEGEND). NO EXCEPTIONS OR SUBSTITUTIONS. DEVICE POLARITY MUST BE OBSERVED. ALL BACK BOX MOUNTING BOX AND JUNCTION BOX COVERS & INTERIORS SHALL BE PAINTED RED. DETECTORS SHALL NOT BE LOCATED WHERE AIR FROM SUPPLY DIFFUSERS COULD DILUTE SMOKE BEFORE IT REACHES THE DETECTORS. DETECTORS SHALL NOT BE INSTALLED WITHIN 3 FEET OF AIR SUPPLY GRILLES OR DIFFUSERS. IF THE DIFFUSERS ARE NOT IN PLACE WHEN DETECTOR BASES ARE BEING INSTALLED CONSULT WITH THE GENERAL CONTRACTOR TO DETERMINE THE HVAC DIFFUSER LOCATIONS. POWER LIMITED CIRCUITS SHALL NOT BE PLACED IN THE SAME CONDUIT, ENCLOSURE, OR RACEWAY WITH NON -POWER LIMITED CIRCUITS. POWER LIMITED CIRCUITS SHALL BE ISOLATED FROM NON -POWER LIMITED CIRCUITS, ELECTRIC LIGHTS, OR POWER CIRCUITS BY A MINIMUM OF 2 INCHES. ALL JUNCTION BOX COVERS SHALL BE MARKED WITH "NON POWER LIMITED" OR "POWER LIMITED". ALL CIRCUITS WHICH ORIGINATE AT THE CONTROL PANEL ARE "POWER LIMITED" UNLESS SPECIFICALLY IDENTIFIED AS "NON -POWER LIMITED". ALL WIRING SHALL BE IN CONDUIT UNLESS OTHERWISE INDICATED ON DRAWINGS. WHERE THE END USER REQUIRES NON METALLIC CONDUIT AND ALL EQUIPMENT TO BE BONDED THE ELECTRICIAN MUST PROVIDE A. BONDING CONDUCTOR TERMINATED AT ALL METALLIC ENCLOSURES. FOR TECHNICAL QUESTIONS CONTACT THE DESIGNER OF RECORD OR FCE PROJECT MANAGEMENT. TEL: (425) 641-2127. A» II CESS DEVICE NUMBER LOOP NUMBER DESIGNATES DETAIL DETAIL NUMBER DESIGNATES DRAWING NUMBER WHERE DETAIL IS LOCATED. A DASH REPRESENTS THE SAME SHEET. DETAIL EFE. \CE NOTE: ALL SLC 3 CABLE/WIRE TO MATCH EXISTING THROUGHOUT THIS PROJECT 08-1690. D AWI\G I\3EX DWG # REV # DRAWING NAME DESCRIPTION F • — AMPERES II' • S ►4 • : • S T 1 Te FA -1.1 - DRAWING LIST, MATERIALS LIST, DETAILS - 08-1690 IR INFRARED • FA -3 2 CEILING DETECTOR LOCATION PLAN - AREA 1 FA -4 2 CEILING WIRING PLAN - AREA 1 A- AFF I •Noi: ' • FA -5.1 - CEILING ADDRESS PLAN - AREA 1 - 08-1690 AMP HOUR M MINI FA -7 2 NOTIFICATION APPLIACNCE CIRCUITS PLAN - AREA 1 FA -8 2 CEILING DETECTOR LOCATION PLAN - AREA 2 .—• MAXIMUM I►G W •I►.G • . — A - FA -9.1 - CEILING WIRING PLAN - AREA 2 - 08-1690 •- 1 ASSEMBLY 1 A11' ' A 1 — Alb A 2 FA -11 2 SUBFLOOR WIRING PLAN - AREA 2 FA -12 2 ' SUBFLOOR ADDRESS PLAN -AREA 2 FA -13 2 FIRE/SMOKE DAMPER PLAN - AREA 2 FA -14 2 NOTIFICATION APPLIACNCE CIRCUITS PLAN - AEA 2 FA -15 2 CEILING DETECTOR LOCATION PLAN - AREA 3 •- • NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION I W Milk ' Al — :- . FA -16.1 - CEILING WIRING PLAN - AREA 3 - 08-1690 •- BATTERY CABINET I 11' . • l - A. A FA -18 2 SUBFLOOR WIRING PLAN - AREA 3 FA -19 2 SUBFLOOR ADDRESS PLAN -AREA 3 FA -20 2 FIRE/SMOKE DAV PER PLAN - AREA 3 FA -21 2 NOTIFICATION APPLIACNCE CIRCUITS PLAN - AREA 3 FA -22 2 CEILING DETECTOR LOCATION PLAN - AEA 4 FA -23 2 CEILING WIRING PLAN — AREA 4 FA -24 2 CEILING ADDRESS PLAN - AREA 4 FA -25 2 SUBFLOOR WIRING PLAN - AREA •4 FA -26 2 SUBFLOOR ADDRESS PLAN -AREA 4 FA -27 2 FIRE/SMOKE DAMPER PLAN - AREA 4 FA -28 2 NOTIFICATION APPLIACNCE CIRCUITS PLAN - AREA 4 FA -29 2 MAJOR COMPONENT LAYOUT FA -30 2 HSSD CO -L0#1 1&2 PIPING ISOMETRIC FA -31 2 HSSD CO -L0#2 1&2 PIPING ISOMETRIC FA -32 2 HSSD CO -L0#3 1&2 PIPING ISOMETRIC FA -33 2 HSSD CO -L0#4 1&2 PIPING ISOMETRIC FA -34 2 HSSD CO -L0#5 1&2 PIPING ISOMETRIC FA -35 2 HSSD CO -L0#6 PIPING ISOMETRIC FA -36 2 FIRE CONTROL PANEL FACP-01 DETAILS FA -37 2 FIRE CONTROL PANEL FACP-02 DETAILS FA -38 2 FIRE CONTROL PANEL MODULE DETAILS FA -39 2 CONNECTION DETAILS FA -40 2 CONNECTION DETAILS FA -41 2 HSSD DISPLAY, CONNECTION DETAIL, ZONE 1 ,2,& 3 FA -42 2 HSSD DISPLAY, CONNECTION DETAIL, ZONE 4,5,& 6 FA -43 2 FIRE ALARM CONTROL PANEL & KIOSK RISER DIAGRAM FA -44 2 CAUSE & EFFECT TABLE FA -45 2 KIOSK - 1 DETAILS FA -46 2 KIOSK - 2 DETAILS FA -47 1 KIOSK & HSSD WIRING PLAN FA -48 1 KIOSK WIRING DETAILS FA -49 0 KIOSK INTERIOR WIRING DETAILS FA -50 0 KIOSK INTERIOR WIRING DETAILS • A.M..-- -- e .•111h. AIM. I• . LT . • • L 1 Te ,..•10....- ..M.... ..mni. _ ........,..... FA -51.1 - KIOSK INTERIOR WIRING DETAILS - 08-1 690 F/A FIRE ALARM SYSTEM THHN FA -52.1 - KIOSK INTERIOR WIRING DETAILS - 08-1690 NOTE: FA -##.1 SHEETS HAVE BEEN INSERTED UNDER JOB# 08-1690 AND ARE THE ONLY SHEETS INCLUDED IN THIS PROJECT SET. ALL OTHER SHEETS HAVE NOT BEEN CHANGED, AND WILL BE UPDATED DURING AS -BUILT REVISION DRAWINGS. tUKWILA FIRE DEPART'! Please call: 575-440Z and give this job No. 6`1-F-Od3 and exact address for shut. down or rsst)rdtior) approval. CEILING 72" FCP P 48" TO HANDLE C 6" MIN. 80" 7//2/ // /2/ FINISHED FLOOR NOTES: 1. DETAIL NOT INTENDED TO SHOW SPATIAL RELATIONSHIP OF DEVICES. REFERENCE FLOOR PLANS FOR ACTUAL LOCATIONS. 6" MINIMUM IF DEVICE CANNOT BE LOCATED AS SHOWN BECAUSE CEILING HEIGHT IS INSUFFICIENT. ABBEVIATIO\ LEGE\D ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION A, AMP AMPERES IDC INITIATING DEVICE CIRCUIT A/R AS REQUIRED IR INFRARED AC ALTERNATING CURRENT J JUMPER ADA AMERICANS WITH DISABILITIES ACT J -BOX JUNCTION BOX AFF ABOVE FINISHED FLOOR LBS, # POUNDS AH AMP HOUR M MINI AHU AIR HANDLING UNIT mA MILLIAMP AO ADDRESSABLE OUTPUT MAX MAXIMUM APP APPROVED MIN MINIMUM ASSY ASSEMBLY MPS MANUAL PULL STATION ASTM AMERICAN STANDARD TESTING & MATERIALS NAC NOTIFICATION APPLIANCE CIRCUIT AUD AUDIBLE NC, N/C NORMALLY CLOSED AUX AUXILIARY NEC NATIONAL ELECTRIC CODE AWG AMERICAN WIRE GAUGE NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION BATT BATTERY NFPA NATIONAL FIRE PROTECTION ASSOCIATION BC BATTERY CABINET NO, N/0 NORMALLY OPEN, NUMBER BLDG BUILDING NPT NATIONAL PIPE THREAD C COMMON, CONDUIT NR NON-RESETTABLE CFM CUBIC FEET PER MINUTE NTS NOT TO SCALE CHK CHECKED 0 OCTAGON CKT CIRCUIT OD OUTSIDE DIAMETER CO2 CARBON DIOXIDE PKG PACKAGE COM COMMON PS POWER SUPPLY CPVC CHLORINATED POLYVINYL CHLORIDE PSIG POUNDS PER SQUARE INCH GAUGE DAC DIGITAL ALARM COMMUNICATOR PVC POLYVINYL CHLORIDE dB DECIBEL R RESETTABLE dBA DECIBEL A SCALE REQ REQUIRED DET DETECTOR, DETAIL REV REVISION DISC DISCIPLINE RM ROOM DIV DIVISION ROR RATE OF RISE DPDT DOUBLE POLE, DOUBLE THROW RX RECEIVE TRANSMITION COMMUNICATION DSGN DESIGN S SQUARE DRWN DRAWN SH SHIELDED DWG DRAWING SHT SHEET E EXISTING SLC SIGNALING LINE CIRCUIT E/R EXISTING TO BE REPLACED SOE SEQUENCE OF EVENTS ELL ELBOW SOL SOLENOID ELR END OF LINE RESISTOR SPST SINGLE POLE, SINGLE THROW EMT ELECTRICAL METALLIC TUBING SUPV SUPERVISORY ENCL ENCLOSURES TB TERMINAL BLOCK EOL END OF LINE TC TERMINAL CABINET F FAHRENHEIT, FIXED TEMPERATURE TER, TERM TERMINAL F/A FIRE ALARM SYSTEM THHN THERMOPLASTIC HEAT RESISTANT NYLON FAC FACILITY TRBL TROUBLE FCP FIRE ALARM CONTROL PANEL TTB TELEPHONE TERMINAL BOARD FT FEET TW TWISTED GA GENERAL ALARM TX SEND TRANSMITION COMMUNICATION GEN GENERATOR TYP TYPICAL GND GROUND U.L. UNDERWRITER'S LABORATORY GPM GALLONS PER MINUTE UV ULTRAVIOLET GRC GALVANIZED RIGID CONDUIT V VOLTS H/S HORN/STROBE VA VOLT AMPS HSSD HIGH SENSI I IVI I Y SMOKE DEI ECTION VAC VOLTS ALTERNATING CURRENT HVAC HEATING, VENTILATION, & AIR CONP'TtONING VDC VOLTS DIRECT CURRENT Hz HERTZ, CYCLES PER SECOND W WATT I/O INPUT/ OUTPUT W/ WITH IAC INDICATING APPLIANCE CIRCUIT WP, W/P WEATHER PROOF ID IDENTIFICATION XFMR TRANSFORMER 0 ,1777 These plans f a .. Prevention Bureau ,c; - standards. .. standards. Accepr.::>.... omissions which do standards and ordnaf:c.:: Fire i..:.l re it City. of :adopted for the adequacy of desi' V. %ri . 7 ,. designer. Additions, deletion. s: - . . .., .-,Vyings after this date will void tris: • �r. uire a resubmittal of revis.,::r ,- ,t approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: /-9 - 0 ? By:' 51 —17„s +4 ( ;fre oLr+ %Q.2< 3c) NOTICE A completed, signed, Tukwila Fire- Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. IMPORTANT OTICE • Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. SCOPE OF WORK ADD/RELOCATE DETECTION TO AN EXISTING FENWAL-NET 200 FIRE ALARM SYSTEM IN THE FOLLOWING AREAS AS NOTED ON THIS DRAWING SET. - 126, 127B, 127A, 128, 129, 130, 131, 106, 107, 108, 109, 110, AND 111. ALL DETECTION IS TO BE RELOCATED/ADDED TO EXISTING FENWAL PANEL #2 RX/TX LOOP 3 (RETAINED FROM EXISTING KIOSK CABINET #2 IN CO -L0-1. - EXISTING BACK BOXES OF DEVICES REMOVED FROM OTHER RX/TX LOOPS SHALL BE COVERED AND REMAIN INSTALLED. THESE COVERS SHALL BE LABELLED TO DESCRIBE THE RX/TX LOOP WITHIN THE BOX. RX/TX LOOP INTEGRITY SHALL BE REATAINED WITHIN THESE BOXES. - INSTALL DOOR MAGNETS AS SHOWN ON THE DRAWINGS IN CORRIDOR 140. - INSTALL ALTRONIX POWER SUPPLY FOR DOOR MAGNETS IN KIOSK #2 CO -LO -3. - INSTALL RELAY OUTPUT MODULE IN KIOSK #2 CO -LO -3 AND ADD TO EXISTING FENWAL PANEL #2 RX/TX LOOP 3 AS SHOWN ON DRAWINGS. - ALL WIRE IS TO BE INSTALLED IN CONDUIT. SITE LOCATION DRAWN BY: JSL DATE: 12/09/08 PAID - 0 2009 It`"` Tukwila Fire. Iq5tJ t1 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 6 wX a N N CO CSD v PROJECT DESCRIPTION: FIRE ALARM REVISIONS TO EXISTING SYSTEM SHEET DESCRIPTION: U) J Q w 0 DRAWING LIST, MATERIALS LIST, TUKWILA 2 DATA CENTER MICROSOFT rti cD CD -41 C) PERMIT SET DESCRIPTION w c JOB NO.: 08-1690 DRAWING NO.: FA-01.1.dwg LEGH\ 3 `?J EXISTING ADDRESSABLE PHOTO SMOKE DETECTOR `IJ EXISTING ADDRESSABLE HEAT DETECTOR LAJ EXISTING ADDRESSABLE INPUT MODULE GAJ EXISTING ADDRESSABLE OUTPUT RELAY MODULE EXISTING ALARMLINE/FN2000 INTERFACE MODULE FO# )'(>0.6'( EXISTING ADDRESSABLE DEVICE ADDRESS O NEW ADDRESSABLE PHOTO SMOKE DETECTOR (REQUIRES NEW WIRE) 02 (31XX) NEW ADDRESSABLE DEVICE ADDRESS II DEVICE NUMBER LOOP NUMBER ADDRESS REFEENCE() RXTX (+) - IN (-) SCALE: INPUT FOR MANUAL STATION OR OTHER CONTACT DEVICE 10K OHMS 1/2 W °V° NTS c7\ ADDRESSABLE DETECTOR 0 8 L 9 S i 2 Z l (-'(+) 8 V (-X+)(-X+5 431431 MS MS 3d 3d 3d 3d (DQ cz 0 +'Q L J � W E8 AI FLAG\OYES 1. THIS DEVICE IS TO BE REMOVED FROM PANEL 1, RX/TX LOOP RELOCATE AS SHOWN AND RE—ADDRESSED ON PANEL 2, RX/TX LOOP 3. LEAVE J—BOX TO RETAIN PANEL 1, RX/TX LOOP 1 INTEGRITY. 2. EXISTING DEVICE RE—LOCATED TO BE INSTALLED ON PANEL 2, RX/TX LOOP 3. DEVICE TO BE PROGRAMMED TO ACTIVATE PRE—ACTION ZONE 5 SOLENOID. 3. NEW DEVICE INSTALLED UNDER JOB# 08-1690. DEVICE TO BE PROGRAMMED ON PANEL 2, RX/TX LOOP 3 TO ACTIVATE PRE—ACTION ZONE 5 SOLENOID. 4. NEW DEVICE INSTALLED UNDER JOB# 08-1690. DEVICE TO BE PROGRAMMED ON PANEL 2, RX/TX LOOP 3 TO ACTIVATE PRE—ACTION ZONE 4 SOLENOID. 5. ACQUIRE PANEL 2, RX/TX LOOP 3 FROM CO—L0-1 KIOSK #2. SEE SHEET FA -9.1 FOR LOCATION. NOTE: FCE TECH TO REVIEW ALL PRE—ACTION ZONING ASSIGNMENTS WITH LEE TECHNOLOGIES TO VERIFY PROPER ZONE MAPPING BEFORE MAKING PROGRAM REVISIONS. EQUIPMENT SHUTDOWNS L 9 S 0 j7 o (-X+£) z v z 3d 3d (-)(+) 3d 3d AO TYPICAL INITIATING LOOP WIRING DETAIL SCALE: NOTE: ALL SLC 3 CABLE/WIRE TO MATCH EXISTING THROUGHOUT THIS PROJECT 08-1690. 57'-112„ 57'-111' .. ��k*T.AT *VA+APA..� M.Zt.ice►i��� `I* Z*4!2 PT "'�`i 7L74i F-4 NWT w 10 Alprik _••.a.. A A . .• _., _ e 1 4,, 471 N N 2#16 18'r -BEAM D1 F02 n F (3182) BAS BMS ELECTRICAL ROOM M3 ELECTRICAL ROOM M2 FO1 122 F02 F02 jeri 2#16 (3176) (3175) DAMPER RELAY-' ELECTRICAL ROOM M1 F02 F02 (3195) (3194) CORRIDOR r4k 4Ni. �►----�--..-------r►—.0v-11 ♦..� 1 ...♦�.♦♦♦♦.. 1 � • V4 ,.� 4t3 "3 li► 0�.•�Diiiiiwsii0 a .► iiii4►Ji`TIIIF i��O�'�:e!e��'vDi iD�k�VG-��i����'� • •••••••••it. lidta, •• +$rA �A0. •7i/s4. 11;X: • ."-ws ' 4+#46- Afr 4.' A '.0 R ''‘ .4 10 .4*. +, _ , A., Fob . ÷ 11► 24� kale 4 ',, I _ F01 ) 0�� h4 ' FA -1 rA L' Loi �4 v.: 1 8' e 1 f40.4f• 316 3+ 41' 6$4/ ra 4#16 ELECTRICAL EMERGENCY ROOM F02 (3164) 2#16 ELECTRICAL EMERGENCY ROOM N N ELECTRICAL BY-PASS ROOM PRE -ACTION SPRINKLER ZN. 4 2#16 F02 ELECTRICAL ROOM MR N N F02 F02 (3 71) (3170) PRE -ACTION SPRINKLER ZN. 4 z 0 0 0 n-' 0 LL 0 LL W W C1) ENT,,,CEILING ADDRESS PLAN SCALE: A 0 0 'ARE" NTS 0 0 0 0 0 0 0 (+) RXTX ( ) OUT AREA 2 AREA 3 L AREA 4 s KEY PLAN 0 0 © 0 0 0 0 0 DRAWN BY: JSL DATE: 12/09/08 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 6 aNg oI PROJECT DESCIPTIO\ SHEET DESCRIPTION: - 08-1690 w CEILING ADDRESS PLAN - MICROSOFT TUKWILA 2 DATA CENTER a0 1 `-`) flq co -c4 c\2 11 co co da 0-) PERMIT SET DESCRIPTION w JOB NO.: 08-1690 DRAWING NO.: FA-05.1.dwg FA5.1 TO 1023 2-#16 TYP 57'-112" 57'-112" REF. SHEET FA48 FOR KIOSK WIRING, TYP. vrma[ acme J��a co Lem if Arm orril�idL�Jl�ti7�►�ilrAmicti log 'mu ma1��'�,�►��%. ��►����.��J��J��E[r>i[�T��Jt1��7l�il��►jl�����1��l�-r.�1�.7`iL�J(�4l-�•C7'L.�i����.vl�lvJi�,7L�Ii ��_�1�17J1�.�'-��i��FI�C7J�`Y►�ia',:.• � `�.��ibil"3�r���� !o!o!e!►!o!�oioi�0000000♦000000�o��♦0000�or00000000���oo�o�o�000�o�����o�o�0000000000���oo�o_o� 84 TO 1016 2-#16 TYP TO FACP-1 2-#16 TYP LOOP -2 ��i�i v''v♦ v' v' 'i �' o�iG'i'ivi'ivi�i�i�v'v''v v'""'►�i�i�i�i�i'i�io"oi"io"''ioioioio''"io"oioioi,,,,v,"o ►ioiO �ioioioioi��oio" �'J � oi�io"�i�iGO�i�i�i�ioi�oio0ioioio+oi� +.....:......��..........����o�oO...���....Di..moi...o�.��..o.Di�o�o�oo�Di.r�o�o��.o�o���o�o.�.�.o♦►o�-�i�o�o�����������o�o�o�o�o�o���o�o��� O000Ooi�ioo♦.oi�i►oioi�o�wo���0000 �000000000�0000�000v�ioioiooi0oi000�o�♦��000������.. A TO 1055 2-#16 TYP 1 4 ri-4V i ". - - - - ' ' ' ' It . Fir r ' -' ' ' ' ' ' ' ' ' ' ' " ' ' ' ' ' ' ' ' ' ' iV2.20,10'17Vig' - - - - ' TIFI ' vi ��.&�� --- .:_�-- iw'_. �.�� ee�e _ __ A� e&i� ,#'fie k TO 1062 2-#16 TYP z 0 z z 0 0 0 L LL W w cn -CN LEGE\ D K2 FA -1 1.w rA-1 LJ rA i L LJ FO# EXISTING KIOSK CABINET EXISTING ADDRESSABLE PHOTO SMOKE DETECTOR EXISTING ADDRESSABLE HEAT DETECTOR EXISTING ADDRESSABLE INPUT MODULE EXISTING ADDRESSABLE OUTPUT RELAY MODULE EXISTING ALARMLINE/FN2000 INTERFACE MODULE EXISTING ADDRESSABLE DEVICE ADDRESS O NEW ADDRESSABLE PHOTO SMOKE DETECTOR (REQUIRES NEW WIRE) 02 (31xx) NEW ADDRESSABLE DEVICE ADDRESS FLAG\OYES NOTE: ALL SLC 3 CABLE/WIRE TO MATCH EXISTING THROUGHOUT THIS PROJECT 08-1690. INDICATES EXISTING WIRE INDICATES FULL HEIGHT WALLS CEILING WIRING PLAN KIOSK 2 IS THE POINT OF CONNECTION FOR PANEL 2 ADDITIONS IN AREA #1 UNDER JOB# 08-1690. 0 0 AREA 1 l © 0 0 0 0 0 AREA KEY PLAN AREA 4 0 0 0 0 0 0 DRAWN BY: JSL DATE: 12/09/08 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 6 PROJECT DESCRIPTION: FIRE ALARM REVISIONS TO EXISTING SYSTEM SHEET DESCIPTION: 0 rn 0 00 0 CEILING WIRING PLAN - AREA 2 TUKWILA 2 DATA CENTER MICROSOFT H C\2 H <4- rti X CrD co F— PERMIT SET DESCRIPTION w JOB NO.: 08-1690 DRAWING NO.: FA-09.1.dwg FA9.1 TO 1017 2-#16 TYP z 0 z z 0 0 0 LL 0 LL LJ LL1 (l) 4#14- TO #14- TO 1061 2-#16 TYP 57'-112" 57'-84" REF. SHEET FA48 FOR KIOSK WIRING, TYP. TO 1001 2-#16 TYP TO FACP-1 2-#16 TYP LOOP 4 (2) L_EGF\3 LI L11 rAI Li rA 1 LE! FO# EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING KIOSK CABINET DOOR MAGNET ADDRESSABLE PHOTO SMOKE DETECTOR ADDRESSABLE HEAT DETECTOR ADDRESSABLE INPUT MODULE ADDRESSABLE OUTPUT RELAY MODULE ALARMLINE/FN2000 INTERFACE MODULE EXISTING ADDRESSABLE DEVICE ADDRESS O NEW ADDRESSABLE PHOTO SMOKE DETECTOR (REQUIRES NEW WIRE) DM NEW DOOR MAGNET F02 (31xx) NEW ADDRESSABLE DEVICE ADDRESS 0 z z 0 0 0 LL N) CN LL LJ LJ (f) INDICATES EXISTING WIRE FLAG\OTES 1. INSTALL ALTRONIX POWER SUPPLY AND RELAY MODULE FOOR DOOR MAGNET RELEASE IN KIOSK 2 AS SHOWN IN DETAIL. FCE TECH TO PROGRAM RELAY MODULE TO OPERATE ON COMMON ALARM TO RELEASE THE DOORS. NOTE: ALL SLC 3 CABLE/WIRE TO MATCH EXISTING THROUGHOUT THIS PROJECT 08-1690. INDICATES FULL HEIGHT WALLS CEILING WIRING PLAN AREA 3 SCALE: 1 /8"=1' 0 0 0 0 1 r •� © © 0 0 0 0 0 L AREA1 AREA AREA 3 AREA4 L KEY PLAN 0 0 0 0 0 0 0 0 0 0 DRAWN BY: JSL DATE: 12/09/08 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 6 TUKWILA 2 DATA CENTER MICROSOFT a0 1'4) P-1 00H 1-1 co X N co PERMIT SET DESCRIPTION JOB NO.: 08-1690 DRAWING NO.: FA -1 6.1.dwg FA16I HSSD HORN/STROBE IN -1 IN -2 IN -3 STB. + - + - + - + - 47K,1 /2W PRE -ACTION HORN/STROBE IN -1 IN -2 IN -3 STB. +-+-+-+- FIRE ALARM PULL STATION PRE -ACTION PULL STATION EPO SWITCH r 10K K,1/2WW VVV r 10K,1/2W VVV L - ALL MODULES ARE ON FCP #2 ADDRESS FOR CO -LO -1, TYP. ADDRESS FOR CO -LO -2, TYP. ADDRESS FOR CO -LO -4, TYP. ADDRESS FOR CO -LO -6, TYP. FIRE ALARM HORN/STROBE T LL- 10K,1 L 10_VVK.11/22W V KIOSK DEVICE ADDRESS SCHEDULE KIOSK DEVICE ADDRESS DESCRIPTION CO -L0 -1-K2 AO F02-3011 CO -L0 -1-K2 AREA 1 FIRE ALARM INPUT " AO F02-3012 NOT USED " Al F02-3013 CO -L0 -1-K2 AUDIBLE PANEL 1 TROUBLE " Al F02-3014 CO -L0 -1-K2 MANUAL ALARM STATION " Al F02-3015 CO -L0 -1-K2 PRE -ACTION ALARM STATION " Al F02-3016 CO -L0 -1-K2 E.P.O. SWITCH CO -L0 -2-K2 AO F02-3027 CO -L0 -2-K2 AREA 2 FIRE ALARM INPUT " AO F02-3028 CO -L0 -2-K2 AREA 2 PRE -ACTION INPUT " Al F02-3029 CO -L0 -2-K2 AUDIBLE PANEL 2 TROUBLE " Al F02-3030 CO -L0 -2-K2 MANUAL ALARM STATION " Al F02-3031 CO -L0 -2-K2 PRE -ACTION ALARM STATION " Al F02-3032 CO -L0 -2-K2 E.P.O. SWITCH CO -L0 -4-K2 AO F02-3056 CO -L0 -4-K2 AREA 3 FIRE ALARM INPUT " AO F02-3057 CO -L0 -4-K2 AREA 3 PRE -ACTION INPUT " Al F02-3058 CO -L0 -4-K2 AUDIBLE PANEL 3 TROUBLE " Al F02-3059 CO -L0 -4-K2 MANUAL ALARM STATION " Al F02-3060 CO -L0 -4-K2 PRE -ACTION ALARM STATION " Al F02-3061 CO -L0 -4-K2 E.P.O. SWITCH CO -L0 -6-K2 AO F02-3082 CO -L0 -6-K2 AREA 4 FIRE ALARM INPUT " AO F02-3083 CO -L0 -6-K2 AREA 4 PRE -ACTION INPUT " Al F02-3084 CO -L0 -6-K2 AUDIBLE PANEL 4 TROUBLE " Al F02-3085 CO -L0 -6-K2 MANUAL ALARM STATION " Al F02-3086 CO -L0 -6-K2 PRE -ACTION ALARM STATION " Al F02-3087 CO -L0 -6-K2 E.P.O. SWITCH TERMINAL STRIPS, IN CABINET. Al MODULE IN CABINET. TT , (3014) 03 N. (3030) m o (3059) Z o (3085) PC (+X-) PC PC (+X-) PC SW A SW B !IDLED ;+);-) 1 2 3 4 5 6 7 8 111 0 111 5 6 7 1010 III0II10 9 Fl —11 L— �J T L- / \ (3015) o U , (3031) o (3060) \o (3086) ' `D PC PC PC PC SW SW LED LED S+x-){+X-) A B (+).'--) 112 3�4�5Q6�7��8 3 4 5 6 7 I I I 1 L- / \ (3016) 03 (3032) m o (3061) \o (3087) .)(1) P+CX P-) (+X P-) A SB"' +; 0 1 2 3 4 5 6 7 8 010i111111 1 111 1 (3013) o , (3029) r- 0058) (3058) \o (3084) PC PC PC PC SW A SW B (� LID 2 0 3 4 5 00I 6 7 8 00 HSSD HORN/STROBE CKT. PRE -ACTION HORN/STROBE CKT. FIRE ALARM HORN/STROBE CKT. 10K 1 oN (3028) m o (3057) 86 (3083) `D PC (+X PC PC -)(+X-) PC z o ; 0 1 2 3 4 0 5 6 7 111 1 111 0 111 5 6 7 1 9 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ®®&®® ®&®®®®000®®0®®®& HSSD HORN/STROBE CKT. PRE -ACTION HORN/STROBE CKT. FIRE ALARM HORN/STROBE CKT. 10K 1 oN (3028) m o (3057) 86 (3083) `D PC (+X PC PC -)(+X-) PC z o ; 0 1 2 3 4 0 5 6 7 111 1 111 0 111 5 6 7 8 9 (301 1) (3027) (3056) (3082) m( 83 00 0 PC PC PC PC z o = (+X-X+X-) n 1 2 3 4 0 5 6 7 J 1/2W CIA SW SWI 50 IIA AUX e ie) MN amr TEIVCRAL MAME MIC MOLT me 6 DU12 OUT4 OU11 OUT2 OUT3 OUT -) (+) (-) (±) (-) MUT asr 1BM.L En VO MOLT [OC ■ P/A 0000 OU71 0012 OUT3 OUT4 INPI WP2 0 OO FAULT J �21 U 2 0 2 .MIC- .o. .a- e'c[rrrn L 10,011.1, eeeeee eeee (L F.A. F.A. F.A. P/A FIRE ALARM PRE -ACTION ALARM TRANSFORMER i � I 120 VAC 3- #12 DEDICATED BREAKERS L_ NOTE: ALL SLC 3 CABLE/WIRE TO MATCH EXISTING THROUGHOUT THIS PROJECT 08-1690. FIRE ALARM HORN/STROBE CKT. FIRE ALARM HORN/STROBE CKT. r fl 0000®0®0 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 0®00®®00®®000®00 FIRE ALARM HORN/STROBE CKT. FIRE ALARM HORN/STROBE CKT. r fl 0000®0®0 1 2 3 4 5 6 7 8 0000000® H N 120 VAC POWER 3#12 FOR CO—LG-1,2/ ,& b l INDICATES EXISTING WIRE OUTLET FOR FLASHLIGHT PLUG-IN CHARGER. IN CABINET. DRAWN BY: JSL DATE: 12/09/08 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 6 N LC) 0 00 rn � co O _ Ln O LU X ¢ LL N Ln 741 CO n N U az PROJECT DESCRIPTION: FIRE ALARM REVISIONS TO EXISTING SYSTEM SHEET DESCRIPTIO\: KIOSK INTERIOR WIRING DETAILS TUKWILA 2 DATA CENTER MICROSOFT 00 rn w PERMIT SET DESCRIPTION w JOB NO.: 08-1690 DRAWING NO.: FA -51.1 .dwg FA 51.1 2-#16, TYP. HSSD HORN/STROBE IN -1 IN -2 IN -3 STB. + - + - + - + - 47K,1/2W A PRE -ACTION HORN/STROBE IN -1 IN -2 IN -3 STB. + - + - + - + - FIRE ALARM PULL STATION PRE -ACTION PULL STATION EPO SWITCH F 10K,,1/2WW VYV L_ F 10KK,,1/2W� YVV DEVICES ON FCP#2 ADDRESS FOR CO -LO -3, TYP. ADDRESS FOR CO -LO -5, TYP. FIRE ALARM HORN/STROBE F 10K,1/2W� YVV L_ KIOSKDEVICE ADDRESS SCHEDULE KIOSK DEVICE ADDRESS DESCRIPTION CO -L0 -3-K2 Al F02-3043 CO -L0 -3-K2 MANUAL ALARM STATION " Al F02-3044 CO -L0 -3-K2 PRE -ACTION ALARM STATION 11 (+X 0- .. 0 ; - .P '. " AO F02-3191 CO -L0 -3-K2 EAST CORRIDOR DOOR MAG POWER CO -L 2 3 _ _: - : ,- _ ,_...,L . _, = Ie, " Al F02-3073 CO -L0 -5-K2 PRE -ACTION ALARM STATION " Al F02-3074 CO -L0 -5-K2 E.P.O. SWITCH DOOR MAG POWER SUPPLY —IAOI 7 L - if NEW UNDER JOB# 08-1690 - 3-#12, TO 120VAC DEDICATED BREAKER. PROVIDED BY ONSITE ELECTRICAL CONTRACTOR. Al Al Al P EPO EOLR EOLR EOLR EOLR EOLR TO K1 DEVICES IN EACH CO -LO AREA NOTE: ALL WIRING TO BE RUN WITHIN KIOSK CABINET & IN THE UNDERFLOOR SPACE OF EACH ROOM. 2-#14, TO DOOR MAGNETS 2-#16, TO RX/TX LOOP 2-#16, TYP. TERMINAL STRIPS, IN CABINET. EMERGENCY POWER OFF SWITCH PRE -ACTION SPRINKLER ZONE MANUAL ALARM SYSTEM BUILDING FIRE ALARM MANUAL ALARM SYSTEM CO -LO -3, KIOSK -K2 WIRING DETAIL SCALE: NTS Al MODULE IN CABINET. 1 F I P 1 NEW DEVICE INSTALLED UNDER JOB# 08-1690FOR DOOR MAG OPERATION EXISTING (3044)83 (3073) 1-9 D O z, C PC PC PC SW SW tED LED + -) + -) A B ,+) -) 1 2 3 4 5 6 7 8 (3043) 0 3 `'(3072) m o D , Z 0 o� PC PC PC PC SW SW LED L (+X -}(+X-) NAM lb A B (+);-) 2 1 2 3 4 5 6 7 8 2 ll III EXISTING (3044)83 (3073) 1-9 D O z, C PC PC PC SW SW tED LED + -) + -) A B ,+) -) 1 2 3 4 5 6 7 8 ( PANEL 2 RX/TX LOOP 3 2#16 (+) NOTE: ALL SLC 3 CABLE/WIRE TO MATCH EXISTING THROUGHOUT THIS PROJECT 08-1690. 1 -17 (3045) o m (3074) P o Z O 411\o� WPWWEREE F(d3 4CUOMB 1 ill I11.I14! ill NAM lb ( PANEL 2 RX/TX LOOP 3 2#16 (+) NOTE: ALL SLC 3 CABLE/WIRE TO MATCH EXISTING THROUGHOUT THIS PROJECT 08-1690. 1 -17 IN OUT \ / ADDRESSABLE LOOP +1- +1_ \ / OUT OUT HSSD HORN/STROBE CKT. PRE -ACTION HORN/STROBE CKT. FIRE ALARM HORN/STROBE CKT. (+) J (+) 4VDC DOOR MAG POWER 2#14 (-) (—) 2 2 2 0 0 X CO 0 et, +R AT- -Dt+ 0 3Sf13 NIVW a-10 NO l 0 9- 1z I ..0 47 Iz 1 P5 I z N '0 N I z 0 O ALTRONIX POWER SUPPLY DOOR vIAGNET WIRING s 120 VAC POWER 3#12 1 23 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 IN OUT \ / ADDRESSABLE LOOP +1- +1_ \ / OUT OUT HSSD HORN/STROBE CKT. PRE -ACTION HORN/STROBE CKT. FIRE ALARM HORN/STROBE CKT. (+) J (+) 4VDC DOOR MAG POWER 2#14 (-) (—) 2 2 2 0 0 X CO 0 et, +R AT- -Dt+ 0 3Sf13 NIVW a-10 NO l 0 9- 1z I ..0 47 Iz 1 P5 I z N '0 N I z 0 O ALTRONIX POWER SUPPLY DOOR vIAGNET WIRING s 120 VAC POWER 3#12 OUT OUT DOOR 24VDC DOOR MAG POWER 4#14 r 1 23 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 OUT OUT DOOR 24VDC DOOR MAG POWER 4#14 r H N 120 VAC POWER 3#12 os SCALE: NTS K2W HOH co \v DACAV 0-3 & 5 0 INDICATES EXISTING WIRE OUTLET FOR FLASHLIGHT PLUG-IN CHARGER. IN CABINET. DRAWN BY: JSL DATE: 12/09/08 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 6 CO U ) c N rso M 0 85 ilg 9; am XR PROJECT DESCRIPTIO\ E ALARM REVISIONS TO EXISTING SYSTEM SHEET DESCRIPTIO\: XC)OSK INTERIOR WIRING DETAILS - 08-1690 z MICROSOFT TUKWILA 2 DATA PERMIT SET DESCRIPTION w CC JOB NO.: 1690 DRAWING NO.: FA-52.1.dwg FA52.1 1 23 4 5 6 7 8 `k® ®&®®& H N 120 VAC POWER 3#12 os SCALE: NTS K2W HOH co \v DACAV 0-3 & 5 0 INDICATES EXISTING WIRE OUTLET FOR FLASHLIGHT PLUG-IN CHARGER. IN CABINET. DRAWN BY: JSL DATE: 12/09/08 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 6 CO U ) c N rso M 0 85 ilg 9; am XR PROJECT DESCRIPTIO\ E ALARM REVISIONS TO EXISTING SYSTEM SHEET DESCRIPTIO\: XC)OSK INTERIOR WIRING DETAILS - 08-1690 z MICROSOFT TUKWILA 2 DATA PERMIT SET DESCRIPTION w CC JOB NO.: 1690 DRAWING NO.: FA-52.1.dwg FA52.1 NATEIAL LIST ITEM SYM REV F MI 1 QTY PART NUMBER MODEL NUMBER DESCRIPTION MANUFACTURER MOUNTING 1 - ����..���.�..-.�--- A 1 - • It A vr5tFn IA Af r..... FA-7 1 FA -7.1 2 NOTIFICATION APPLIACNCE CIRCUITS PLAN - AREA 1 1 FACP-X - ' 2 74-200000-100 FN2000 MULTI LOOP WITH MOTHER BOARD FENWAL 72" AFF 2- FA -14.1 2 NOTIFICATION APPLIACNCE CIRCUITS PLAN - AREA 2 FA -15.1 2 CEILING DETECTOR LOCATION PLAN - AREA 3 F - 6 Naz - RELAY MODULE FENWAL IN FACP-1,2 3 - FA -19.1 2 SUBFLOOR ADDRESS PLAN -AREA 3 2 ' 74-200009-002 - POWER SUPPLY MODULE ONLY - 4 AMPS 36" HARNESS FENWAL IN FACP-1,2 4 - i 8 74-200005-002 RXTX RXTX MODULE FENWAL IN FACP-1,2 5 - - 1 - - - - - - 6 - ( - - - - - - - 7 - - : - I - - - - - 8 =C -X a - 1 1 74-200000-005 - EXPANSION ENCLOSURE FENWAL 72" AFF 9 - 1 1 74-200000-006 - EXPANSION BACKPLANE FENWAL - 10 - ( - 1 1 74-200009-010 - POWER SUPPLY/CHARGER FENWAL - 11 - - I 1 74-200009-003 - POWER SUPPLY MODULE, 8" HARNESS FENWAL - 12 - - i 6 74-200001-001 - AGENT RELEASE MODULE FENWAL IN FCP #2 13 AL - 12 73-100001-001 - ALARMLINE/FN2000 INTERFACE MOD. FENWAL - 14 - ) 3 73-117068-016 NYLON SENSOR 650' PER COIL, ALARMLINE LINEAR THERMAL CABLE FENWAL - 15 - ( - I 1 ' 74-100017-001 - BATTERY ENCLOSURE FOR EXTRA BATTERIES FENWAL BELOW FCP 16- ( - 4 PS -12560 - BATTERY 12V, 50AH POWERSONIC IN BATTERY CABINET 17 e ( O - 1 1280 71-402001-100 PSD -7152 INTELLIGENT PHOTO DETECTOR FENWAL ON BASE 18 ® ( - 10 70-404001-100 THD -7252 INTELLIGENT THERMAL DETECTOR FENWAL ON BASE 19 - ( - 1290 70-400001-100 6SB 6" UNIVERSAL DETECTOR BASE FENWAL 4-S BOX 20 ri ( ( - 171 70-407008-001 Al ADDRESSABLE CONTACT INPUT N.O. FENWAL 4-S BOX 21 Ao ( 36 45 70-408004-001 AO ADDRESSABLE RELAY OUTPUT FENWAL 4-S BOX 22 - 1 10 70-403001-152 DH -2000 DUCT HOUSING W/PHOTO DETECTOR FENWAL - (`-' t 23 - - 10 06-129500-005 - 96" SAMPLING TUBE FENWAL - 24 h ( - 25 29-320000-280 - MANUAL PULL DBL ACTION WITH F.A. LEGEND FENWAL 1 -GANG DEEP BOX 25 ( - 1 89-100055-001 - HSSD MODULAR POWER SUPPLY FENWAL IN KIOSK 26 o/ ( - 36 75-000085-001 NS -24110W -FR HORN/STROBE 110cd (FIRE) FENWAL 4-S BOX 27 ;O', ( - 15 75-000005-001 RSS-24110W-FR 110cd STROBE (FIRE) UNIVERSAL MOUNT FENWAL 4-S BOX 28 ;O', (( - 16 75-000005-001 RSS-2415W-FR 15cd STROBE (FIRE) UNIVERSAL MOUNT FENWAL 4-S BOX 29 0/ ( - 7 75-000084-001 NS -2475W -FR HORN/STROBE 75cd (FIRE) FENWAL 4-S BOX 30 int ( - 16 75-000083-001 NS -2430W -FR HORN/STROBE 30cd (FIRE) FENWAL 4-S BOX 31 04 ( - ` 43 75-000081-001 NS -2415W -FR HORN/STROBE 15cd (FIRE) FENWAL 4-S BOX 32 - 1 74-300000-501 RDCM REMOTE DISPLAY MODULE FENWAL . 60" AFF 1 FSA 33 ( - 6 74-300000-502 RDM REMOTE DISPLAY CONTROL MODULE FENWAL IN KIOSK 34 - ( - 4 PS -12/24-8 - POWERPATH 8 AMP WHEELOCK IN KIOSK CABINETS 35 - - 8 PS -12120 - 12V, 12AH BATTERY POWERSONIC IN POWERPATH 36 - 3 89-100058-004 - HSSD 4 ZN. UNIT/POWER SUPPLY FENWAL IN KIOSK FissD# 37 - ( - 3 89-1000053-000 - HSSD 4 ZONE ENCLOSURE FENWAL IN KIOSK 38 ( - 11 89-100000-031 - MODULAR DETECTOR/FAN BOX 0.003 TO 0.03% FENWAL 72" AFF 39 - I - - - 6 6 89-100074-001 89-100074-002 - - ANALASER SAMPLING POINT LABEL ROLL OF 100 ANALASER SAMPLING PORT LABEL ROLL OF 100 FENWAL FENWAL - - 40 41 - K1 - - 6 6 89-100074-003 KIOSK -1 - - , ANALASER SAMPLING PIPE LABEL ROLL OF 100 MAIN KIOSK STATION FENWAL CUSTOM - - 42 43 1K2 ( - 6 KIOSK -2 - SECONDARY KIOSK STATION CUSTOM - 44 R (( ( - ' 23 MR -101 - SHUT DOWN RELAY AIR PRODUCTS 1 GANG DEEP BOX 45 - - 2 74-200036-001 - NETWORK INTERFACE CARD FENWAL IN FACP-1 & 2 46 - 6 70-200200-001 - ADDRESSABLE SIGNAL DEVICE MODULE FENWAL 4-S BOX sDM ( 47 - 12 XX -MANUAL PULL STATION - SUPPRESSION ' FENWAL IN KIOSK 48 ( - 12 XX - EMERGENCY POWER OFF SWITCH S.T.I. IN KIOSK 49 f ( - 12 XX - EPO MINI STOPPER COVER W/ HORN S.T.I. IN KIOSK 50 ( - 24 MT -2415W -FR - MULTI -TONE HORN/STROBE WHEELOCK IN KIOSK 51 ( - 12 - - 5# CO2 EXTINGUISHER - IN KIOSK 52 ( - 12 VC -86-40 - FLOOR TILE PULLER - IN KIOSK 53 f - 12 45117 - RECHARGABLE FLASHLIGHT STREAMLIGHT IN KIOSK 54 - } 12 HC -2318R - EXTINGUISHER CABINET LARSON IN KIOSK 55 ( C - 1 AL4000LPD4 - 24VDC POWER SUPPLY FOR DOOR MAGS ALTRONIX IN KIOSK 56 ( - ) 4 4 FM -998-24 - DOOR MAGNETS NOTIFIER 2" x 4" x 1-3/4" 57 ( ( - ) 2 DSM -12/24 - DUAL SYNC MODULE WHEELOCK 4-S BOX 58 ( - ) 3 ZRS-MCW-FR - WALL MOUNT MULTICANDELA STROBE - RED WHEELOCK 4-11/16" X 2.125" BACK BOX tvtri A FRE DEPARTmatil Please call: 575.4407 3(td give this job o. to -r+ 10- + .xact address for shut. ,,uf, or restoration approval El Without Comments G' As Noted in Red D Per The Attached Letter ...-,. plans have been reviewed by The Tukwila Fire .ntlon Bureau for conformance with current City ;cards. Acceptance is subject to errors and .: Lsions which do not authorize violations of adopted _fndards and ordinances. The responsibility for the to qu fcy of design rets totaliy with the designer. deletions or revisions to these drawings;after this date void this acceptance and will require a resubmittal of revised drawings for sub equent approval. Final acceptance is subject to Reid test and Inspection by The Tukwila Fire Prevention Bureau. Date: 4 -1 Li -10 By:_ DRAWING INDEX DWG # REV # DRAWING NAME v - v _, �- r FA F DRAWING LIST, MATERIALS LIST,& DETAILS -1 1 FA -2.1 F GENERAL NOTES Sc DETAILS F)( -"S.1' 1 • - 1 - �iItc`'r. `.� FA -5.1 F CEILING ADDRESS PLAN AREA 1 - ����..���.�..-.�--- A 1 - • It A vr5tFn IA Af r..... FA-7 1 FA -7.1 2 NOTIFICATION APPLIACNCE CIRCUITS PLAN - AREA 1 FA -8.1 2 CEILING DETECTOR LOCATION PLAN - AREA 2 FA -10.1 F CEILING ADDRESS PLAN - AREA 2 A•: W�..!.�.j-- Li 0- rr1- -fr vvq FA-12.1 2 SUBFLOOR ADDRESS PLAN -AREA 2 FA -13.1 2 FIRE/SMOKE DAMPER PLAN - AREA 2 FA -14.1 2 NOTIFICATION APPLIACNCE CIRCUITS PLAN - AREA 2 FA -15.1 2 CEILING DETECTOR LOCATION PLAN - AREA 3 F - 6 Naz .:SAN-.�9gCk.ter-..-..-...-..-.,-..-..e ..-..-..-..-., FA -17.1 F CEILING ADDRESS PLAN - AREA 3 FA -19.1 2 SUBFLOOR ADDRESS PLAN -AREA 3 FA -20.1 2 FIRE/SMOKE DAMPER PLAN - AREA 3 FA -21.1 2 NOTIFICATION APPLIACNCE CIRCUITS PLAN - AREA 3 FA -221A 2 DETECTOR - AREA 4 F�'1/13�r1Tr1 /CE�I�L�INN�G I /A�LOCATION AAN.S/1 AN-...�'1 F/A�PLAN J"'I%� 7 `l^\r1rti�".►./1/1/1�r1I-\r'�.-1I'1, F CEILING ADDRESS PLAN - AREA 4 FA -241 -, A- 1C L•0- ""I- 1 -1A _ A-4• FA -26.1 2 SUBFLOOR ADDRESS PLAN -AREA 4 FA -27.1 2 FIRE/SMOKE DAMPER PLAN - AREA 4 FA -28.1 2 NOTIFICATION APPLIACNCE CIRCUITS PLAN - AREA 4 FA -29.1 2 MAJOR COMPONENT LAYOUT FA -30.1 2 HSSD CO-LO#1 1&2 PIPING ISOMETRIC FA -31.1 2 HSSD CO-LO#2 1&2 PIPING ISOMETRIC FA -321 2 HSSD CO -L0#3 1&2 PIPING ISOMETRIC FA -331 2 HSSD CO-LO#4 1&2 PIPING ISOMETRIC FA -34.1 2 HSSD CO-LO#5 1&2 PIPING ISOMETRIC HSSD CO -L0#6 PIPING ISOMETRIC FA -35.1 2 FA -36.1 2 FIRE CONTROL PANEL FACP-01 DETAILS FA -37.1 2 FIRE CONTROL PANEL FACP-02 DETAILS FA -38.1 2 FIRE CONTROL PANEL MODULE DETAILS FA -39.1 2 CONNECTION DETAILS FA 40.1 2 CONNECTION DETAILS FA -41.1 2 HSSD DISPLAY, CONNECTION DETAIL, ZONE 1,2,& 3 FA -42.1 2 HSSD DISPLAY, CONNECTION DETAIL, ZONE 4,5,& 6 FA -43.1 2 FIRE ALARM CONTROL PANEL & KIOSK RISER DIAGRAM FA -441 2 CAUSE & EFFECT TABLE FA -45.1 2 KIOSK - 1 DETAILS FA -46.1 2 KIOSK - 2 DETAILS FA -47.1 1 KIOSK & HSSD WIRING PLAN FA -48.1 1 KIOSK WIRING DETAILS FA -49.1 0. KIOSK INTERIOR WIRING DETAILS FA -50.1 0. KIOSK INTERIOR WIRING DETAILS FA -51.1 5 KIOSK INTERIOR WIRING DETAILS ,SFA I ¢.K., ,Q)Af�,W FA -53.1 F VIRTUAL ZONE CABINET WIRING DETAILS Prow Strikes 4 +sem ' Prtper ore1a1-70 11% e'N e•ct( q,ICtvH, NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems: Failure of test will result in a Re -inspection Fee and termination of the testl'ng, NOTE: ONLY SHEETS WITH REVISION CLOUDS ARE INCLUDED IN PROJECT 10-1450. SCOPE OF WO - INSTALL ADDRESSABLE RELAYS TO RELEASE DOOR MAGNET LOCKS IN GENERAL ALARM CONDITION. - PULL SLC FROM NEAREST EXISTING BFAP DEVICE AS SHOWN. - INSTALL RELAY MODULES FOR VIRTUAL ZONES. - ADJUST PROGRAMMING TO REFLECT VIRTUAL ZONES IN ORDER TO ACHIEVE ACCURATE ACTIVATION OF THE DESIRED VIRTUAL ZONE RELAY. 0 0 0 0 © © o ® ® "Rmi //4. V fm.f:r EA 2 i r AREA 3 KEY PLAN 0 PAID JUN - 9 2010, � TUKWILA FIRE l�� w DRAWN BY: JSL DATE: 10/02/09 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 7 PROJECT DESCRIPTION: FIRE ALARM REVISIONS TO EXISTING SYSTEM SHEET DESCRIPTION: DRAWING LIST, MATERIALS LIST, & DETAILS LA 2 DATA CENTER MICROSOFT TU OOrnrnc)rn00 00000 c0 (ID Cq CD CD 0 0 u7 rn 00 0 m O COD cn 0 r-. co CO co r -o 0 CO O CC w DESCRIPTION L.� w CZi U m 1 JOB NO.: 10-1450 DRAWING NG NO.: FA- 01.1.dwg FA1.1 AR3REVIATIO\ LEGE\D ABBREVIATION( DESCRIPTION IABBREVIATIONI DESCRIPTION CODE A, AMP AMPERES ID IDENTIFICATION A/R AS REQUIRED IDC INITIATING DEVICE CIRCUIT AC ALTERNATING CURRENT IR INFRARED ADA AMERICANS WITH DISABILITIES ACT J JUMPER AFF ABOVE FINISHED FLOOR J -BOX JUNCTION BOX AH AMP HOUR LBS, # POUNDS AHU AIR HANDLING UNIT M MINI AO ADDRESSABLE OUTPUT mA MILLIAMP APP APPROVED MAX MAXIMUM ASSY ASSEMBLY MIN MINIMUM ASTM AMERICAN STANDARD TESTING & MATERIALS MPS MANUAL PULL STATION AUD AUDIBLE NAC NOTIFICATION APPLIANCE CIRCUIT AUX AUXILIARY NC, N/C NORMALLY CLOSED AWG AMERICAN WIRE GAUGE NEC NATIONAL ELECTRIC CODE _ BATT BATTERY NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION BC BATTERY CABINET NFPA NATIONAL FIRE PROTECTION ASSOCIATION BLDG BUILDING NO, N/0 NORMALLY OPEN, NUMBER C COMMON, CONDUIT NPT NATIONAL PIPE THREAD CFM CUBIC FEET PER MINUTE NR NON-RESETTABLE CHK CHECKED NTS NOT TO SCALE CKT CIRCUIT 0 OCTAGON CO2 CARBON DIOXIDE OD OUTSIDE DIAMETER COM COMMON PKG PACKAGE CPVC CHLORINATED POLYVINYL CHLORIDE PS POWER SUPPLY DAC DIGITAL ALARM COMMUNICATOR PSIG POUNDS PER SQUARE INCH GAUGE dB DECIBEL PVC POLYVINYL CHLORIDE dBA DECIBEL A SCALE R RESETTABLE DET DETECTOR, DETAIL REQ REQUIRED DISC DISCIPLINE REV REVISION DIV DIVISION RM ROOM DPDT DOUBLE POLE, DOUBLE THROW ROR RATE OF RISE DSGN DESIGN S SQUARE DRWN DRAWN SH SHIELDED DWG DRAWING SHT _ SHEET E EXISTING SLC SIGNALING LINE CIRCUIT E/R EXISTING TO BE REPLACED SOE SEQUENCE OF EVENTS ELL ELBOW SOL SOLENOID ELR END OF LINE RESISTOR SPST SINGLE POLE, SINGLE THROW EMT ELECTRICAL METALLIC TUBING SUPV SUPERVISORY ENCL ENCLOSURES TB TERMINAL BLOCK EOL END OF LINE TC TERMINAL CABINET F FAHRENHEIT, FIXED TEMPERATURE TER, TERM TERMINAL F/A FIRE ALARM SYSTEM THHN THERMOPLASTIC HEAT RESISTANT NYLON FAC FACILITY TRBL TROUBLE FCP FIRE ALARM CONTROL PANEL TTB TELEPHONE TERMINAL BOARD FT FEET TW TWISTED GA GENERAL ALARM TYP TYPICAL GEN GENERATOR U.L. UNDERWRITER'S LABORATORY GND GROUND UV ULTRAVIOLET GPM GALLONS PER MINUTE V VOLTS GRC GALVANIZED RIGID CONDUIT VA VOLT AMPS H/S HORN/STROBE VAC VOLTS ALTERNATING CURRENT HSSD HIGH SENSITIVITY SMOKE DETECTION VDC VOLTS DIRECT CURRENT HVAC HEATING, VENTILATION, & AIR CONDITIONING _W WATT Hz HERTZ, CYCLES PER SECOND W/ WITH I/O INPUT/ OUTPUT, WP, W/P WEATHER PROOF IAC INDICATING APPLIANCE CIRCUIT XFMR TRANSFORMER ADD DEVICE NUMBER LOOP NUMBER ESS EFE"EncE DESIGNATES DETAIL NUMBER DESIGNATES DRAWING NUMBER WHERE DETAIL IS LOCATED. A DASH REPRESENTS THE SAME SHEET. DETAIL REFEE\CE HSSD PIPING \OTES: 1. EXACT ROUTING OF SAMPLING NETWORK TO BE DETERMINED AT THE TIME OF INSTALLATION. 2. USE CPVC OF INDICATED SIZES FOR SAMPLING NETWORK. 3. ALL HSSD PIPING SEGMENTS SHOULD BE CAPPED A MAXIMUM OF 6 INCHES FROM THE FINAL SAMPLING HOLE. 4. ALL HSSD PIPING MUST BE CLEANED & FREE OF DEBRIS PRIOR TO INSTALLATION. 5. ALL HSSD PIPING AND J -BOXES MUST BE SEALED TO PREVENT AIR LEAKAGE. 6. DRILL HOLES IN CAPS AND CLEAN BEFORE CONNECTING TO PIPING NETWORK. 7. INFORM SYSTEM ENGINEER OF VARIATIONS IN FIELD ROUTE TO NETWORK PRIOR TO INSTALLATION. 8. LABEL PIPING NETWORK AND SAMPLING POINTS. PIPING SHALL BE LABELED "SMOKE DETECTOR SAMPLING PIPE. DO NOT DISTURB." AT INTERVALS OF NOT MORE THAN 20 FEET. 9. DO NOT PLACE SAMPLING POINTS IN DIRECT AIR STREAM. 10. DO NOT PLACE SAMPLING POINTS WITHIN 3'-0" OF SUPPLY AIR DIFFUSER. 11. ALL PIPE LENGTHS NOT SHOWN SHALL BE CLOSE NIPPLE. GE\ERAL NOTES: 1. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM. 2. DO NOT INSTALL DETECTOR WITHIN 3'-0" OF AIR SUPPLY DIFFUSER. 3. ALTERATIONS OR VARIATIONS FROM DRAWINGS SHOULD BE RED LINED. 4. NOTIFY ENGINEERED FIRE SYSTEMS OF ANY DESIGN QUESTIONS OR CHANGES. 5. REFERENCE INSTRUCTION MANUAL DURING INSTALLATION OF FIRE CONTROL PANEL. 6. USE ONLY U.L. LISTED DEVICES. 7. DO NOT INSTALL DETECTOR HEADS UNTIL FINAL CLEANING HAS BEEN PERFORMED. DESIGNATES NODE NUMBER. FLOW CALCULATION NODE POINT �EFEENCE CODE REQUIRE SIE\TS ELECTRICAL NOTES: 1. INSTALLATION SHALL COMPLY WITH NFPA 70, PARTICULARLY ARTICLE 760 SECTION C, AND SHALL ALSO COMPLY WITH NFPA 72 AND ALL LOCAL ELECTRICAL CODES AND LOCAL JURISDICTION REQUIREMENTS. 2. CONDUIT SHALL BE EMT AND AS SPECIFICALLY NOTED ON PRINTS. 3. CONDUIT OR CABLE INDICATED ON PRINTS IS DIAGRAMMATIC AND CAN BE REROUTED PER FIELD REQUIREMENTS. 4. AC POWER SHALL NOT OCCUPY THE SAME CONDUIT AS FIRE ALARM CIRCUITS (MOST FIRE ALARM CIRCUITS ARE NEC CLASS 3). 5. FIRE PROTECTION WIRING NOT REQUIRED TO BE IN CONDUIT PER SPECIFICATIONS, CODE OR USER REQUIREMENTS, SHALL BE TYPES FPL, FPLR OR TYPE FPLP. TYPE FPLP SHALL BE USED IN PLENUMS. WIRING SHALL BE SECURED TO BUILDING STRUCTURE. 6. FIRE PROTECTION CIRCUITS SHALL NOT BE PARALLEL BRANCHED (TEE TAPPED) TO ENSURE SUPERVISION OF WIRING. 7. POLARITY OF ALL FIRE DETECTION WIRING SHALL BE MAINTAINED THROUGHOUT ENTIRE SYSTEM; WIRE SHALL BE MARKED AND IDENTIFIED WHERE SPLICED. 8. THE FIRE ALARM PANEL GROUND SHALL BE A SEPARATE CONTINUOUS GROUND WIRE BACK TO THE SOURCE GROUND; CONDUIT GROUND IS NOT ACCEPTABLE PER MANUFACTURER'S SPECIFICATIONS. 9. ALL FIELD WIRING SHALL BE CHECKED FOR SHORTS AND GROUNDS. WIRING SHALL THEN BE MEGGARED BEFORE CONNECTION OF DEVICES TO THE SYSTEM WIRING. WIRING SHALL BE MADE UP FOR THIS TEST SO THAT ALL WIRING COMPRISING THE SYSTEM IS TESTED. MEGGAR TEST RESULTS SHALL BE RECORDED AND SUBMITTED WITH SYSTEM TEST RESULTS. 10. FIRE ALARM PANEL SHALL BE SUPPLIED BY A DEDICATED CIRCUIT BREAKER. OTHER EQUIPMENT SHALL NOT SHARE THE FIRE ALARM CIRCUIT. THIS BREAKER SHALL BE LOCKED AND CLEARLY MARKED "FIRE ALARM CIRCUIT CONTROL". 11. POWER SHALL NOT BE APPLIED TO THE FIRE ALARM PANEL UNLESS A REPRESENTATIVE FROM THE MANUFACTURER IS PRESENT. 12. RECORD ALL CHANGES TO WIRING CONNECTIONS, DEVICE PLACEMENT, WIRE ROUTING OR CONDUIT RUNS ON AS -BUILT DRAWINGS. RETURN THE AS -BUILT DRAWINGS TO ENGINEERED FIRE SYSTEMS, INC. CEILING //////////////////// FCP 72" P 48" TO HANDLE ;0; E 6" MIN. 80" 7//2/iiiiiiiiiiiiii)iiiiiiiiiii�iii� FINISHED FLOOR SEC ION SCALE: NTS NOTES: 1. DETAIL NOT INTENDED TO SHOW SPATIAL RELATIONSHIP OF DEVICES. REFERENCE FLOOR PLANS FOR ACTUAL LOCATIONS. 6" MINIMUM IF DEVICE CANNOT BE LOCATED AS SHOWN BECAUSE CEILING HEIGHT IS INSUFFICIENT. 0 0 0 ® 0 0 0 L 0 0 0 0 0 0 0 0 AREA 1 i AREA2 KEY PLAN 0 0 0 0 -0 0 0 DRAWN BY: JSL DATE: 10/02/09 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 7 PROJECT DESCRIPTION: FIRE ALARM REVISIONS TO EXISTING SYSTEM SHEET DESCRIPTION: GENERAL NOTES & DETAILS MICROSOFT TUKWILA 2 DATA CENTER rn rn rn 00 000 N co O N O ec)oLr) cNI LO 0) CO O O oo ( 0) DESCRIPTION w U CCI w JOB NO.: 10-1450 DRAWING NO.: FA-02.1.dwg FA2.1 CODE DATE/VERSIONS UNIFORM BUILDING CODE 1994 UNIFORM FIRE CODE 1994 UNIFORM MECHANICAL CODE 1991 ELECTRICAL NOTES: 1. INSTALLATION SHALL COMPLY WITH NFPA 70, PARTICULARLY ARTICLE 760 SECTION C, AND SHALL ALSO COMPLY WITH NFPA 72 AND ALL LOCAL ELECTRICAL CODES AND LOCAL JURISDICTION REQUIREMENTS. 2. CONDUIT SHALL BE EMT AND AS SPECIFICALLY NOTED ON PRINTS. 3. CONDUIT OR CABLE INDICATED ON PRINTS IS DIAGRAMMATIC AND CAN BE REROUTED PER FIELD REQUIREMENTS. 4. AC POWER SHALL NOT OCCUPY THE SAME CONDUIT AS FIRE ALARM CIRCUITS (MOST FIRE ALARM CIRCUITS ARE NEC CLASS 3). 5. FIRE PROTECTION WIRING NOT REQUIRED TO BE IN CONDUIT PER SPECIFICATIONS, CODE OR USER REQUIREMENTS, SHALL BE TYPES FPL, FPLR OR TYPE FPLP. TYPE FPLP SHALL BE USED IN PLENUMS. WIRING SHALL BE SECURED TO BUILDING STRUCTURE. 6. FIRE PROTECTION CIRCUITS SHALL NOT BE PARALLEL BRANCHED (TEE TAPPED) TO ENSURE SUPERVISION OF WIRING. 7. POLARITY OF ALL FIRE DETECTION WIRING SHALL BE MAINTAINED THROUGHOUT ENTIRE SYSTEM; WIRE SHALL BE MARKED AND IDENTIFIED WHERE SPLICED. 8. THE FIRE ALARM PANEL GROUND SHALL BE A SEPARATE CONTINUOUS GROUND WIRE BACK TO THE SOURCE GROUND; CONDUIT GROUND IS NOT ACCEPTABLE PER MANUFACTURER'S SPECIFICATIONS. 9. ALL FIELD WIRING SHALL BE CHECKED FOR SHORTS AND GROUNDS. WIRING SHALL THEN BE MEGGARED BEFORE CONNECTION OF DEVICES TO THE SYSTEM WIRING. WIRING SHALL BE MADE UP FOR THIS TEST SO THAT ALL WIRING COMPRISING THE SYSTEM IS TESTED. MEGGAR TEST RESULTS SHALL BE RECORDED AND SUBMITTED WITH SYSTEM TEST RESULTS. 10. FIRE ALARM PANEL SHALL BE SUPPLIED BY A DEDICATED CIRCUIT BREAKER. OTHER EQUIPMENT SHALL NOT SHARE THE FIRE ALARM CIRCUIT. THIS BREAKER SHALL BE LOCKED AND CLEARLY MARKED "FIRE ALARM CIRCUIT CONTROL". 11. POWER SHALL NOT BE APPLIED TO THE FIRE ALARM PANEL UNLESS A REPRESENTATIVE FROM THE MANUFACTURER IS PRESENT. 12. RECORD ALL CHANGES TO WIRING CONNECTIONS, DEVICE PLACEMENT, WIRE ROUTING OR CONDUIT RUNS ON AS -BUILT DRAWINGS. RETURN THE AS -BUILT DRAWINGS TO ENGINEERED FIRE SYSTEMS, INC. CEILING //////////////////// FCP 72" P 48" TO HANDLE ;0; E 6" MIN. 80" 7//2/iiiiiiiiiiiiii)iiiiiiiiiii�iii� FINISHED FLOOR SEC ION SCALE: NTS NOTES: 1. DETAIL NOT INTENDED TO SHOW SPATIAL RELATIONSHIP OF DEVICES. REFERENCE FLOOR PLANS FOR ACTUAL LOCATIONS. 6" MINIMUM IF DEVICE CANNOT BE LOCATED AS SHOWN BECAUSE CEILING HEIGHT IS INSUFFICIENT. 0 0 0 ® 0 0 0 L 0 0 0 0 0 0 0 0 AREA 1 i AREA2 KEY PLAN 0 0 0 0 -0 0 0 DRAWN BY: JSL DATE: 10/02/09 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 7 PROJECT DESCRIPTION: FIRE ALARM REVISIONS TO EXISTING SYSTEM SHEET DESCRIPTION: GENERAL NOTES & DETAILS MICROSOFT TUKWILA 2 DATA CENTER rn rn rn 00 000 N co O N O ec)oLr) cNI LO 0) CO O O oo ( 0) DESCRIPTION w U CCI w JOB NO.: 10-1450 DRAWING NO.: FA-02.1.dwg FA2.1 1. USE THIS EXISTING DEVICE AS POINT OF CONNECTION FOR NEW ADDRESSABLE OUTPUT MODULE. 2. NEW ADDRESSABLE OUTPUT MODULE IS BEING INSTALLED TO RELEASE DOOR MAGNET CONNECTION DURING A GENERAL ALARM CONDITION. ADDRESSABLE PHOTO SMOKE DETECTOR ® ADDRESSABLE HEAT DETECTOR k( ADDRESSABLE OUTPUT RELAY MODULE A� ALARMLINE/FN2000 INTERFACE MODULE J ADDRESSABLE PULL STATION F02 (31xx) ADDRESSABLE DEVICE ADDRESS DRAWN BY: JSL DATE: 10/02/09 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 7 Ai AI Ar,� _��►_____��ii_____ii_wi____i i ' piri, wm....Am.. p g g -Ng me W k ;Elsal SHEET DESCRIPTION: CEILING ADDRESS PLAN - AREA ADDRESSABLE OUTPUT MODULE CONTACT RATINGS RESISTIVE CONTACT RATING: 2A © 30VDC INDUCTIVE CONTACT RATING: 1.OA ® 30VDC, 0.6PF, 0.6A 0 120VAC, 0.35PF MICROSOFT TUKWILA 2 DATA CENTER ooOrnrnrnrno0 �00000 CD CO NCOh-0) N N o o<- N o r- o co in N Dor--00 1- 0 DESCRIPTION > w JOB NO.: 10-1450 DRAWING NO.: FA -05.1. dwg ___�________wAwAr..___________. FA5.1 PRE -ACTION SPRINKLER ZN. 3 z 0 ID 7 0 U (Y 0 L_ LC) O LL LLJ (f) A Ail Ar AAT AP _ 4: 4. ,r Ar AZ .4 A _ _, ir /,/ A . . .3-,,- „...., ______......"..2.11, FA 044, I ii6r , ortor ,. elf . I am /0 14 Air - - rte �. �C -Art!J4FA� MPER RELAY Av74 AA iterj f ///////I/////% ////I/////1AIIRI F/I//11/I� /moi 4,fr'.Aar Ar FAD LE WA) alp "J. Adj AN IV`il i///WIWAI/////1//IM//1�/////////1///I� �' er-Fl era ., . 6171 � /��. .moi f�rAM O �Aihr/. 1/ FLAG\ OTOS 1. USE THIS EXISTING DEVICE AS POINT OF CONNECTION FOR NEW ADDRESSABLE OUTPUT MODULE. 2. NEW ADDRESSABLE OUTPUT MODULE IS BEING INSTALLED TO RELEASE DOOR MAGNET CONNECTION DURING A GENERAL ALARM CONDITION. 0 ID 0 U (Y 0 LL LL LTJ INDICATES FULL HEIGHT WALLS CEILING ADDRESS PLAN 0 0 0 0 AEA 2 SCALE: 1/8"= 0 0 0 O 0 0 0 M AREA, 1 : AREA 3 0 0 0 0 AREA 4 KEY PLAN 0 0 0 0 0 0 0 0 0 DRAWN BY: SSL DATE: 10/02/09 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 7 111 JOB NO.: DRAWING NO.: FA-10.1.dwg PRE -ACTION SPRINKLER ZN. 2 z 0 z 0 0 rY 0 LL 0 LL LJ W (f) 57'-112" 57'-84" --7-1 Ai 41 .W frill 9 IN Fr i r, " e ovAr iir, 6) roar Dv gro I/ IZ A'-frk IIIA /i_ mu 11 i ►i .►i . fir„,, ....., .....r�rr t i►ri ��irii i� ca!ivy, gmr _...__ft . __. ._____ _, _ cm V/ l7/ II r,4G � • r! O I I USE THIS EXISTING DEVICE AS POINT OF CONNECTION FOR NEW ADDRESSABLE OUTPUT MODULE. NEW ADDRESSABLE OUTPUT MODULE IS BEING INSTALLED TO RELEASE DOOR MAGNET CONNECTION DURING A GENERAL ALARM CONDITION. VIRTUAL ZONE RELAYS ARE BEING PROVIDED AND SHALL BE LOCATED IN A CABINET LOCATED HERE. AND CONNECTED TO SLC -5 (SEE FLAG NOTE 4). SEE NEW SHEET FA 53.1 FOR POSSIBLE CABINET DEVICE LAYOUT AND DESCRIPTIONS. ACQUIRE SLC -5 FROM SUB -FLOOR DETECTOR 5041 LOCATED DIRECTLY BELOW THIS DEVICE. ' �il9� r:.fJ • r.;ie' ' �:�1 ' �;� ``tL I LJ p F01 iev-�' '���, F01 O (4209 ' l r • z 0 z 0 0 f 0 L> - CN LL W LLI (f) at* �, F' F' F' © (4221) �,,� �� �f I� % 4222 �AAII �� ,�,i I, Afr Ili F-7 I FA s rrnme rAwmi.4 rA rA ri r. wA A el v. ma • Ir.. • 71Nr. .2 • ra ..morAmr-AumrAwAmrrA A'Ner;%. r -me ow. Now. 11-Cwz s rm. • rm FA lorm r. • d v rA Eli, w ow.ummix A; • w. pi •7. r re 4 V V. Irffj110°1/1 16. I DAAAI12)A /4 I 664: AAEra INDICATES FULL HEIGHT WALLS CEILING ADDRESS PLAN - AREA 3 0 0 0 0 0 0 0 0 0 0 0 ® 0 AREA, SCALE: 1 /8"=1' 0 0 0 AREA2 0 0 0 0 KEY PLAN L AREA 4 DRAWN BY: JSL DATE: 10/02/09 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 7 N LOO Cn CNI Q� N Ln Q) W X za N- d N .,-O N z 141 N -D1 wus PROJECT DESCRIPTION: FIRE ALARM REVISIONS TO EXISTING SYSTEM DESCIPTION: ro w CEILING ADDRESS PLAN - MICROSOFT TUKWILA 2 DATA CENTER O N LC) CO N O O 00 O O CO O O N w 0 J w O O LC) 0i CO CO O 02 CO O (/) O 03 0) O 02 O CO (/) O 00 O 1 CO 0 0 0 F- U w w 0 U 0 O rn CO 00 O CO w (n w DESCRIPTION LL w 0 U m JOB NO.: 10-1450 DRAWING NO.: FA -1 7.1.dwg FA17.1 58'-1 4 " 58'-01" 57'-11 t" AaraeWl#rAlAWFAI #A,mAir,AdAwAlwAlwAwil DAMPER RELAY TYP. 8 PLCS. x 0 z 0 U PRE -ACTION SPRINKLER ZONE 1 CHILLER PUMP YARD Ar I: i•---i/r 1I�-I�=I�' _ - ->- _ -►=,r . -.. A WET SPRINKLER SYSTEM PA05 PA04 PA03 PA02 PA01 PRE -ACTION SPRINKLER ZONE PA06 4 = TAMPER SWITCH = LOW AIR PRESSURE SWITCH = WATER FLOW (PRESS. SW - P/A) SWITCH = 24VDC SOLENOID VALVE NOTE: ALL DEVICES PROVIDED & INSTALLED BY SPINKLER CONTRACTOR. 0 —0 Ell F02 (2150) F02 0-c n (• 2151) ®-Q AI O -0 AI 0 0 O 0 0 F02 F02 (2165) F02 0-0 AI (• 2166) F02 4-0 n (2161) F02 --0 n (• 2162) F02 o'Q AIS LTJ 4 AI F02 —0 ^I 2159 F02 o -Q AI 2160 ❑J F02 ®-0 n 2155 F02 — 0 I 1 (2156) • 2157 F02 0 F02 F02 4-0 o� AI F02 n 2153 F02 AI F02 41-0 n (2167) F02 --0 fl (2168) F02 o� AI (• 2169) L�1 F02 F02 .......... ?170:C2T7i) 9 9 F A C P 2 E C A B F02 (2172) TO PIV OOM #151 SCALE: 1/2"=1' FLAGNOTES 1. USE THIS EXISTING DEVICE AS POINT OF CONNECTION FOR NEW ADDRESSABLE OUTPUT MODULE. 2. NEW ADDRESSABLE OUTPUT MODULE IS BEING INSTALLED TO RELEASE DOOR MAGNET CONNECTION DURING A GENERAL ALARM CONDITION. CEI INDICATES FULL HEIGHT WALLS ING ADDRESS PLAN — AREA 4 PRE -ACTION SPRINKLER ZONE 6 0 0 0 0 0 0 0 0 0 0 SCALE: 1/8"=1 VrARlAi zmiE/A/24 0 0 0 0 0 KEY PLAN // DRAWN BY: JSL DATE: 10/02/09 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 7 Z glks W U5 §1 DESCRIPTION: LLJ 0 IZ w V) >- CD z X w O z 0 w IY J SHEET DESCRIPTION: CEILING ADDRESS PLAN - AREA 4 MICROSOFT TUKWILA 2 DATA CENTER W 0 COC24� Poi CV1.4 oornrnrna)co '-00000 ocor icy 00 Ns I— N N 0 0 N— CV 0 LL)��OCC) LC)N 0 0 .- 0 0 V) LU z -57 0 N J 0 z (n lY LC) CO CO O O 00 rn 0 rn C0 CO 0 O N. 00 0 1 CO 0 0 rn c0 00 O m (/) DESCRIPTION L.� W 0 U m U-1 tr JOB NO.: 10-1450 DRAWING NO.: FA-24.1.dwg FA24.1 F FROM NEAREST SLC 2 DEVICE. (+) RXTX (-) IN Z-1 FUEL POLISHER Z-2 LOADING DOCK thil0400.0 L 9 o � z o z a) Oo L < o E8 (!)M 5 0 17 Z L (-X+)(-X+) 3d Od Od Od AO F01 (5188) Oil I L 9 S z U z 0 17 Z (-x+)(-x Od 3 Od 3 AO F01 (5189) Z-3 RPU ROOMS UPS GENERATORS o L 9 z 0 iv £ 1. (-X+X-X+ 3d 3d Od 3 AO F01 Z-4 MECHANICAL ROOMS Z-5 ELECTRICAL ROOMS L 9 5 z (1) c Oo S.- Q vJ w Eo 0 z I! L -x+)(-X+ 3d 3d Od 3 1A01 F01 Z-6 COLO 1/TELCO L 9 5 z U 0 1 £ z (-X+X-X+ z Od Od Od 0 F01 AO L 9 z 501£Z l (-X+)(-X+ z Od Od Od 0 AO F01 5190) Z-7 COLO 2 Z-8 COLO 3/TELCO L 9 5 20 z a) o L W EO 0 17 l (-X )(-X+ 3d Od Od 3 AO F01 5191 0 0 Z-9 COLO 4 44000I I L 9 S O t7£ Z L o (- +) (-X+ z z Od Od Od O a) c Oo Q CD EO AO F01 $192) Z-10 LOBBY AND BREAK ROOM 7777 L 9 S O t £ Z 1 z (-X+X-X+) 3d 3d Od Od F01 (5193) Z-11 BACK OFFICE 0000111 I L9SOiOd Od O . (-X+)' -X+ z Od Z L AO F01 $194) 0 0 Z-12 COLO 5/TELCO L 9 5 z U z 0 c Oo -1-� Q vw EO (I)m 0 z l 3d O Od O AO F01 $195) 77771 L 9 S 0t7£ Z l z a) Oo -1�Q L W E O (-X+X-X+) Od Od 3d Od AO F01 Z-13 COLO 6 Z-14 FIBER ROOM L 9 5 z U zZ a) c Ooo vw Ea (1)m 0 £ l (-X+) (-X+ Od Od Od O AO F01 Z-15 CHILL WATER PUMP ROOM L 9 S 0 1' £ Z l (-X+) (-X+) z o z Od Od Od Od a) c O o 0 Eo AO F01 (5196) Z-16 WEST HALLWAY Q 0 0 L 9 5 z o z a) c O o 0 G E8 0 17 Z (-X+X-X+) 3d 3d Od 3d AO F01 (5197) P._ARM VRTU,4 Z-17 EAST HALLWAY *Ii hili it L 9 z U z c O o vCI E8 0 i► Z (-X+)(-X+ 3d Od Od O AO F01 (5198) ZONE CABINE CABINET LOCATED IN FIBER TERMINATION CLOSET B. ROOM 147B. SEE SHEET FA17.1. SCALE: VZC NTS L 9 0 2 c O o vW Eo 0 tr L (-X+)(- Od 3d Od 3 AO F01 (5199) Z-1 (+) RXTX ( ) OUT 174 reeiaMaSgrL *art ,4r#434x4 ��S+W 4V..7II.!SPI l‘r,r0 ."4J.494r4P4V.A4�is►W4Vfh4V4.?mo.-IAAA01;A .401ei/ 4%1.1,A41�iN4.n!�.1 A FIDE ALARM VICTUAL ZON MAP SCALE: NTS DRAWN BY: JSL DATE: 10/02/09 PROJECT MGR: JS APPROVED BY: RFV # OF SHEETS: 7 PROJECT DESCRIPTION: FIRE ALARM REVISIONS TO EXISTING SYSTEM SHEET DESCRIPTION: VIRTUAL ZONE CABINET WIRING DETAILS MICROSOFT TUKWILA 2 DATA CENTER CD N 10 OD 01 N CO O u') O C0 00 n CO 0) O J CO N 10 0) 0 00 O m O w N W U J 0_ 0t_ U z 00 0 0 CO O 0_ (f) O U W U DESCRIPTION W U CO w JOB NO.: 10-1450 DRAWING NO.: FA-53.1.dwg FA53.1 BULK MAIN PLAN SCALE: 1/8".1'-0" (I � (I II " II V J =--11---II--=--1H- =11- = -1====11- =-=_IL n -- __ L - --- � reg I / - r r T fi -r- 1� it �f fl -1L II �� I I L® \ -t H E P E A I \ - - J r T r.� I II J .II . �\ r` 11- n T II 11 • rL-J 1 ( -_•.I r r_.I1_,� iJ + Li T 4 - /.- r, - -'---. --- -...-- - 108 4 �fl \f\/A TIN O 0 (TON P1it n T =r a IP. )07v ' 0 c. _v ,i II 1 ri LL•J I ., I_ I-; a REMOTE AREA ORDINARY HAZARD HYDRAULICALLY CALCULATED TO PROVIDE A DENSITY OF .40 GPM/ENTIRE AREA FLOW AT NODE BOR: 539.8 GPM AT 64.8 PSI FILE: TUK2.SDF -H L II STORAGE ROOM PLAN NEW OR EXISTING 1" OUTLET (TYP,) �`- EXISTING PIPING 36" FLEXHEAD DROP w/ �- MOUNTING BRACKET CEILING TILE - SPRINKLER HEAD FLEXHEAD DETAIL NOT TO SCALE SCALE: 1/8"=1'-0" GENERAL NOTES 1. = EXISTING EXTENDED COVERAGE FIRE SPRINKLER HEAD. 2. 51; = EXISTING EXTENDED COVERAGE FIRE SPRINKLER HEAD TO REMAIN. 3. DASHED LINES INDICATE EXISTING FIRE SPRINKLER PIPING. 4. NEW CEILING HEIGHT TO BE 10'-O." 5. EXISITNG FIRE SPRINKLER PIPING LOCATED AT 18'-O." 6. SEE FLEX HEAD DETAIL. FLOW TEST SUPPLY ROO V OTES: 'NOTICE 'Weld stamps must be inspected before pipe is hung. DQal paint pipin prior to hydrostatic test approval. 11 ► D n CCETE Without Comments As Noted In Red Per The Attached Letter I nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subiect to errors and omissions which do not authorize violations of adopted stanaaros and oralnances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this.acceptance and win require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire, Prevention Bureau. Date: 57.2- VDO By: eo_ aU TUKWILA FIRE DEPAi I -Maple_ Please call: 575.4407 and give this job No. Cg- 2-2 2 - and exact address for shut' town or restoration approvaE WWORTANTNOTICE Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minimum of 48 hours in advance of the date you want an aj „pection. 1. STORAGE WITHIN THIS ROOM TO BE 4 ROWS OF SHELVING WITH A MAXIMUM DEPTH OF 30 INCHES, BAY LENGTH OF 48 INCHES AND MAXIMUM 24" VERTICAL SPACE BETWEEN SHELVES. 2. STORAGE ON SHELVES WILL CONSIST OF UNCARTONED, UNEXPANDED PLASTICS. 3. FACTORY MUTUAL DESIGN DIRECTIVES TO BE .30 GPM/ENTIRE ROOM. 4. NFPA 13 DESIGNED REQUIREMENTS TO REQUIRE .40 GPM/ENTIRE ROOM. - 5. FINAL DESIGN OF .40 GPM IS PER NFPA 13 (2007 EDITION), TABLE 13.2.1 STATIC 120 RESIDUAL FLOW SOURCE LOCATION SITE RISER GUAGE SCOPE OF WORK MODIFY FIRE SPRINKLER PROTECTION FOR STORAGE ROOM AND ENLARGED OFFICE. 5. 1::tt:s l:;0t1i-Pl 23,7:: 1•c,c;) %1151 inc. isS.< vTi.i3::':`t'� VICI\ITY VAP HANGER LEGEND A B E F G K "U" HOOK M N P R S COACH SCREW ROD BM. CLAMP W/ "STRAP EYELET FLUSH SHELL CEILING FLANGE SIDE BEAM BRACKET SHORT CLIP ALL THREAD ROD TOGGLE NUT POWDER DRIVEN STUD EXPANSION BOLT PIPE SPIKE T U V W X Y Z STATE CERTIFICATION SPRINKLER LEGEND 2 - WAY EARTHQUAKE BRACE 4 - WAY EARTHQUAKE BRACE ceC0_ V/X SPRINKLER ORIFICE SIZES AND TYPE 1- x 0 1- z W z a W W N �� 2 5 3 7 1 SPRAY 16 8 16 2 0 0 3 4 17 32 SPRAY 2 3 7 1 8 16 2 SIDEWALL 1 2 TEMP RATING DRY TYPE STRUCTURE TO CENTER LINE OF PIPE IN INCHES FITTING LEGEND P PIPE -O -LET 0 165° 212° 286° 350° 500° z w C3 -J Y zz eea Na 0 za z�Lu 0 • 0 1- r tn 1/2„ 1" 3/4" 1„ 1/2" 1„ 1" 1„ 1/2" oz z3 zo wo 0 0 1„ 1„ 1„ 1/2" 1/2" 1„ 1/2" F PLAIN END FIT FITTING SN GROOVED SHAPED NIPPLE APPROVAL REQUIRED CITY OF TUKWILA TSN 'THREADED SHAPED NIPPLE FACTORY MUTUAL SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE TYCO TYCO ELO 231 ELO SSP 11.2 K HEAD FINISH CHROME ESCUTCH FINISH ALU 401 TEMP QTY 165' 11 EC -14 EXT. COV. REC. SSP a% 14.0 K CHROME WHITE 155' 5 TOTAL 16 QUALITY CONTROL BY DATE APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2002 EDITION. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2002 EDITION. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2002 EDITION 6. JOINING OF PIPE AND FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, 2002 EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED 8Y A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. ALL WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY OTHERS 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA 1. DESIGN PER NFPA 13 (200"7 EDITION). AND FACTORY MUTUAL REQUIREMENTS. PIPE NOTES 1.. ALL THREADED PIPING TO BE SCH-40. 2. ALL GROOVED PIPING TO BE FIRE FLOW. REVISIONS NO DATE BY DESCRIPTION 1 5-22-08 CC REVISED CEILING HEIGHT TO 10'-0" CONTRACT WITH: HERMANSON CORP. row - 1221 2ND AVE NORTH KENT, WA 98032 JASON BENNETT PROJECT NAME: MS-TUK2 TUKWILA EAST 3433 120th PL S TUKWILA, WA 98168 VICTOR FROST 206-396-1759 1�4�1' L' i:fog 2 2 2008 Tukwila Fire .30,z,176 /sy- 2707 70TH AVENUE EAST TACOMA, WA 98424 PATRIFP099CF WWW.PATRIOTFIRE.COM clintc@potriotfire.com TEL: (253) 926-2290 FAX: (253) 922-6150 DESIGNER CLINT CARR SHEET DATE 5-16-08 JOB NO. 12-11259 1 OF 1 FP -1 VESTIBULE DOCK SECURITY 113 ;; 114 ------------------------ ii ' J Lt/ • - .• r 1..:.:•_; 1 1,.EXISTING 'CEILING Ta v R. REUOVED ,RNSE.EXISTING 3 tk4ES.T9 ROOF -REPLACE PENDO+n WITH UPRIGrfI� GST -20 (1/4"x-2") 21/2" MAXIPESIZE GST -30 ('/4'x-3" 4'MAX PIPE SI E 3" ATR ADJUSTABLE RING `HANGER SAMMY SCREW ROD AND RING b r.� MEN 115 WOMEN 116 EC TEL/ DATA 119 FIBER TERM. CLOSET A ti 137A OPS/ CUSTOMER WORK AREA 138 SPRINKLER PIPING PLAN SCALE: 3/32" = 1'-0" O Wrenout Comments Gl As Isloted in Red ►�: Per The Attached Letter ala plans have been reviewed by The Tukwila Fire i'itIon Bureau for conformance with current City r ;girds, Acceptance is subject to error$ and ulo+�s which do rant authorize violations of adopted ,w.rds and ordinances. The responsibility for the . aCV of design rests 'tot lly with the designer. ons, dei?rioil' or revisions to these drawings after ; t -rt• vs.oiil void tris :acceptance and will require a ,vomit : ,ai of rcviseer drawings for subsequent approval. ,a,al acceptance is subject to field test and Inspection by Tuitwila Fire Prevention Bureau. SWG-20 (1/4"x-2") 3" MAX PIPE SIDE SWC -25-380 (3/4 x-21/2") 4' MAX PIPE SIZE "'ATR ADJUSTABLE RING ANGER HORIZONTAL SAMMY SCREW i • FIBER TERM, CLOSET B 137E 1 TUKWILA PERE DEPARTMENT Piease call 206-575-V07 and give this Fire Paerm.L No. J - S-Igo and exact address for f..hlut- dovvn or restoration approval. O CORRUGATED STAINLESS STEEL HOSE WITH STAINLESS STEEL BRAID MULTI—PORT BRACKET DJUSTABLE HUB SPRINKLER HEAD" \CEILING TILE DETAIL OF FLEX HEAD DYNA-THREAD (ASTM A-135) NOMINAL OUTSIDE DIA. INSIDE DIA. WALL THICKNESS LBS/FT H2O GAL/FT PIPE SIZE IN. mm IN. mm IN. mm PLUS PIPE 1 1.315 33.4 1.660 42.2 1.900 48.3 2.375 60.3 1.080 27.4 1.408 35.8 1.639 41.6 2.104 53.4 .118 3.0 .126 3.2 .131 3.3 .136 3.5 1.73 2.54 3.22 4.57 .048 .082 .111 .195 AREAS OF WORK NO SCALE 35TH AVE SOUTH GENERAL NOTES SPRINKLER SYSTEM DESIGN PER N.F.P.A. 13 2010 ED. ALL MATERIALS SHALL BE U.L. LISTED OR F.M. APPROVED FOR FIRE PROTECTION FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. 13 SYSTEM ACCEPTANCE AND APPROVAL REQUIREMENTS SHALL COMPLY WITH N.F.P.A. #13 IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY- TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE , DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF ALL ELECTRICAL, PAINTING OF PIPE/ PIPE IDEN1IFICATION, FURRING, CUTTING OR PATCHING TO BE BY OTHERS SPRINKLER HEADS ARE NOT NECESSARILY LOCATED IN CENTER POINT OR QUARTER POINT OF CEILING TILE FOR CLARITY NOT ALL HANGERS ARE SHOWN, BUT WILL BE INSTALLED PER NFPA13 EXISTING BUILDING IS HYDRAULICALLY CALCULATED ORDINARY HAZARD GROUP 2 OCCUPANCY CLASS BUILDING IS ORDINARY HAZARD 2 OCCUPANCY CLASS IN ALL AREAS AND OR ROOMS UNLESS OTHERWISE NOTED THREADED PIPE 1" — 2" PIPING TO BE 'DYNA—THREAD' EXISTING SYSTEMS EXTENDED COVERAGE HEADS MAXIMUM SPACING AT 18' X 18' IF SHEET IS NOT 34" x 22" SCALE ACCORDINGLY SPRINKLERS SYM DESCRIPTION • EXISTING CENTRAL 'ELSO' CHROME/WHITE PENDENT 14.5K 3/4"NPT rJ EXISTING CENTRAL 'ELSO' BRASS UPRIGHT 14.5K 3/4"NPT • TYCO 'EC -14' BRASS UPRIGHT 14.OK 3/4" NPT • TYCO 'EC -14' EXT. COV. HORIZONTAL SIDEWALL 14.OK 3/4"NPT • TYCO 'TY—FRB' EXT. COV. HORIZONTAL SIDEWALL 8.OK 3/4"NPT AS-BUILTS TENANT IMPROVEMENT TAX PARCEL #: 102304-9081 SIN TEMP QTY 155 155 TY6137 155 TY6237 155 TY4332 155 FIRE PROTECTION PLAN FOR TELEX • 3433 S 120TH PL TUKWILA WA 98168 Fel /X FIRE PREVENTION, INC. P.O. BOX 594 PORT ORCHARD, WA 98366 T. 360.871.1985 F. 360.871.2262 FOXFIPI127M8 www.foxfireprevention.com DRAWN BY ABC JOB NO. 13-753 DATE 24JUL13 DWG NO. 1 OF 2 PAID JUL 31 2013 TUKWILA FIRE 27%' '-- ®----------°---------°----------°----------°d-i----1---------°--------- ®----------°------- • • • '---------- °--------- •--------- •----------° --1------- •--------- •---------- • NEW CEIUNG TO REPLACE OLD CEIUNG SAME ELEVATION AND GRID LAYOUT EXISTING LINES AND DROPS TO REMAIN NO CHANGE TO EXISTING SPRINKLER SYSTEM THIS AREA --- ---- °--- 2 •— 2 — ° � ----- ® I-- 2 ® 2 0-----2 ----o 2 -O 6 • DYNA-THREAD (ASTM A-135) NOMINAL OUTSIDE DIA. INSIDE DIA. WALL THICKNESS LBS/FT H2O GAL/FT PIPE SIZE IN. mm IN. mm IN. mm PLUS PIPE 1 1.315 33.4 1.660 42.2 1.900 48.3 2.375 60.3 1.080 27.4 1.408 35.8 1.639 41.6 2.104 53.4 .118 3.0 .126 3.2 .131 3.3 .136 3.5 1.73 2.54 3.22 4.57 .048 .082 .111 .195 EXISTING PIPING PLAN SCALE: 1/8" = 1'-0" Mil I 0 4' 8' 16' U Without Comments As Noted in Red Per The Peached Letter 11-Eg - 4- .r r-- r-- - 11- L• L• Je2 2 eck- Jet e MAINTENANCE GARAGE 2 (o- -® MAINTENANCE SHOP EXISTING CEILING TO BE REMOVED RAISE EXISTING 3 LINES TO ROOF REPLACE PENDENTS WITH UPRIGHT (14 OFFICE 2 Je 2 2 BAS BMS -® EXISTI\ IL CONTROL CENTER • G PIPING • PLA SCALE: 1/8" = 1'-0" AREAS OF WO NO SCALE GENERAL NOTES SPRINKLER SYSTEM DESIGN PER N.F.P.A. 13 2010 ED. ALL MATERIALS SHALL BE U.L. LISTED OR F.M. APPROVED FOR FIRE PROTECTION FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. 13 SYSTEM ACCEPTANCE AND APPROVAL REQUIREMENTS SHALL COMPLY WITH N.F.P.A. #13 IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE , DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF ALL ELECTRICAL, PAINTING OF PIPE/ PIPE IDENTIFICATION, FURRING, CUTTING OR PATCHING TO BE BY OTHERS rRINKLER HEADS ARE NOT NECESSARILY LOCATED IN CENTER POINT OR QUARTER POINT OF CEILING TILE R CLARITY NOT ALL HANGERS ARE SHOWN, BUT WILL BE INSTALLED PER NFPA13 ISTING BUILDING IS HYDRAULICALLY CALCULATED ORDINARY HAZARD GROUP 2 OCCUPANCY CLASS OUILDING IS ORDINARY HAZARD 2 OCCUPANCY CLASS IN ALL AREAS AND OR ROOMS UNLESS OTHERWISE NOTED THREADED PIPE 1" — 2" PIPING TO BE 'DYNA—THREAD' EXISTING SYSTEMS EXTENDED COVERAGE HEADS MAXIMUM SPACING AT 18' X 18' 35TH AVE SOUTH v O N LC) These plans have been reviewed by The Tukwila Fire Prevention Bureau for cor;for:nance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted .�;andards and ordinances. The responsibility for the adequacy of design rests tot. Ily with the designer. Additions, deletions or revis:o;ls to these drawings after this date will void th:'s acceptance and will require a resubmittal of revised drawin- s for subs- - approval. Final acceptance is subject to field test ection by The Tukwila Fire Prevention Bureau. Date: - I - 13 By. TUKWILA EIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No, and exact address for shut - SPRINKLERS SYM DESCRIPTION • EXISTING CENTRAL 'ELSO' CHROME/WHITE PENDENT 14.5K 3/4'NPT O EXISTING CENTRAL 'ELSO' BRASS UPRIGHT 14.5K 3/4"NPT O TYCO 'EC -14' BRASS UPRIGHT 14.OK 3/4" NPT 2" 1 /2„ IF SHEET IS NOT 34" x 22" SCALE ACCORDINGLY 1" 2" 1 /2" TENANT IMPROVEMENT TAX PARCEL #: 102304-9081 SIN TEMP QTY 155 -- 155 -- TY6137 155 6 FIRE PROTECTION PLAN FOR TELEX 3433 S 120TH PL TUKWLA WA 98168 Jol X FIRE PREVENTION, INC. P.O. BOX 594 PORT ORCHARD, WA 98366 T. 360.871.1985 F. 360.871.2262 FOXFIPI127M8 www.foxfireprevention.com DRAWN BY ABC JOB NO. 13-753 DATE 11MAR13 DWG NO. 1 OF 1 PAID MAR 12 2013 TUKWILA FIRE ..271.Zr7 Z�?Qo' ao*/0/ oei