HomeMy WebLinkAboutPP - 10430 EAST MARGINAL WAY SOUTH - UNIFIED GROCERS / ASSOCIATED GROCERS ET AL - PERMITS AND PLANS10430 EAST MARGINAL WAY SOUTH ASSOCIATED PERMITS B92-0193 91-357 91-023 90-527 90-491 90-311 90-057M 90-118 89-442 09-S-203 11-S-265 UNIFIED GROCERS ADVANCED FIRE PROTECTION SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206.575-4407 xtw appu ..auuu accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: D 32 3 6 4 gt z 8 Site Address: /0 430 &. H r.1LG i PJ /IL lA *Y $ .%K►) ILA Suite Number p Floor; Tenant Name: 'J i't t F l CD CQ0C.6612S New Tenant? Q - Yes [ - No Property Owner's Name: E A t-NE Mailing Address: 0 . `.DX 3-763 \tt l i . cte tz4- City State Zip CONTACT PERSON -if there are questions about the submittal. Name; Tot-A't C Day Telephone: 204, --73o ^ 9 70,E Company Name: MoV ktCOD TtC Mailing Address: 1) 0S4gvtlaS4 gm -1z E-mail Address:. k Q CL ' At, V R fir-, ►\JaT CitY Fax Number: 42$ .- 4 Ate-- s©? "7 Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): ADD Cl e) SEW S PQ t t4.14. -o S t 1.4 (6) XE LA C E 2S PERMIT APPLICATION NATES Value of Cons etlon In all uses; avalue of construction amount should be entered by the applicant Thi figure will be reviewed and is subject -to -possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demo. 1 HEREBY CERTIFY THAT I HAVE READ AND IDCAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FORTHISPERM T. Plan-P.tit Aeodoc 5/14/10 Date: tt - 72 t I Day Telephone: 2C1 13v i 1 aS FFg FP Farm 8 City of Tukwila FILE Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM SEP 6 199¢ loiin W. Rants, Mayor Thomas P. Keefe, Fine Chief Permit No. /392- V Project Name r / ` FWL l f /4/"I4 / S 334/ c • n/b'1/-7ve/C S r Address ig sS oea 4j, '7N ceo certj 6 Retain current inspection schedule Needs shift inspection Zone S A-53 53 Suite # Approved without correction notice 2,7,4 i /1: L /-1,4s br f/t / Approved with correction notice issued It -)6 } '/FJdJL-'3 /-x=G-4"1.1 5/74-- Sprinklers: /7 - Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: 5/2 Authorized Signature e/51,2/1: Date FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575-4404 • Fax (206) 575-4439 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM FEB 2 1 1991 Gary L. VanDusen, Mayor Control No. 9'.:(9-5-2/ Permit No. Project Name A c '65 C/ /4 7 ) Address 7 ±J C" Afr;j<' /C. Suite # (72 fP es -9-4-5. Retain current inspection schedule Needs shift inspection 14 Approved without correction notice Approved with correction notice issued. Sprinklers: 4/` Fire Alarm: t Hood & Duct: Al Halon: .N Monitor: Pk - Pre -Fire: A/ Permits: Authorized Signature Date FINALAPP.FRM T.F.D. Form F.P. 85 CITY OF TUKVWILA )ntrol No 90— Central Permit System Permit No 6673a FINAL APPROVAL FORM TO:. ❑ Building ❑ Planning Public Works oFire Dept. JUL 5 1990 ❑ Police ❑ Parks/Recreation Project Name /14-1 5 Address 3V s- /V ,( Type of Permit(s) / ' A This project is nearing completion. Please investigate your area of responsibility and indicate below either your final approval or necessary corrections. If no response is received within one week, it will be assumed that the project is of no concern to your department and a certificate of occupancy may be issued. J This project is NOT approved by this department; the following corrections are necessary: O ( ( ( ) ( ( () ( O 54`2' () S'C*r_ () 4=' -- z -)46(6-670_, t 7 --a. 70 Authorized Signature Date 1 This project is appro)7ed by this department: Authorized Signat`ure i' Date CPS Form 3 r City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Gary L. VanDusen, Mayor Control No. %7o ! 3/// Permit No. 697-3c3 Project Name 1116, c ,) 7 E 6i r Address 3 5 a 1 5 • A/ vA-e f- 2//( Suite # •-~ ""° Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Y Fire Alarm: A/ Hood & Duct: A/ Halon: A/ Monitor: /4 P7 Pre -Fire: A/ Permits: )14/4-1,1/ /47-74)_4;/.2__ Authorized 744i - Authorized Signature Date -/'z/M/ FINALAPP.FRM T.F.D. Form F.P. 85 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM DEC 6 1990 Gary L. VanDusen, Mayor Control No. c- </ /2 -- Permit No. L c 32 Project Name 1`' S ‘T Address 33C/ A(C'2 FO/r< Suite # -- - )( Retain current inspection schedule Needs shift inspection Approved without correction notice X Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: /\/ Halon: nr \. Monitor: A. Pre -Fire: Permits: 74-"16--/9,-(L_ 4-) g72 -- Authorized Signature 13NALAPP . FRM Date T.F.D. Form F.P. 85 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Unified Grocers 10430 East Marginal Way S Permit No.: 11-S-265 Date: November 29, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test: and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Fire Department Review (512) Control #B92-0193 • FILE John W. Rants, Mayor June 18, 1992 Re: National Freight Handlers - 3301 South Norfolk St., Tukwila, Wa. Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "A11 Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1-6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1-6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher", with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC 10.505A) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1-6.5) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 12.106(c)) City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Page number 2 John W. Rants, Mayor Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 12.106-12.111) 3. A fire alarm system is required for this project. The fire alarm system shall meet the requirements of NFPA 72 and City Ordinance #1528. An approved automatic sprinkler system may be installed in lieu of a fire alarm system. Local U.L. central station supervision is required. (City Ordinance #1528) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1528) (UFC 10.503) Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File slj City o Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Fire Department Review Control #91-357 (513) Gary L. VanDusen, Mayor August 28, 1991 Re: Associated Grocers - 3301 South Norfolk Street Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) (UFC 10-1 (3-1)) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1-6.6), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1-6.6) (UFC 10.301) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC 10.301) 2. Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) Exit signs shall be installed at required exit doorways and where otherwise necessary to clearly City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Page number 2 Gary L. VanDusen, Mayor indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with a minimum letter width of 3/4". (UBC 3314) (UFC 12.108) 3. An approved fire alarm system is required per City Ordinance #1327. An approved automatic sprinkler system may be installed in lieu of a fire alarm system. (Plans must be submitted to the Fire Prevention Bureau for approval prior to installation.) Local UL Central Station supervision is required. (City Ordinance #1327) The fire alarm system shall have the written approval of the Tukwila Fire Department. No work shall commence without approved drawings. (City Ordinance #1327) Every exterior portion of a building must be within 300' of a fire hydrant, measured around the perimeter of the building. (City Ordinance #1567) Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Fire Department Review Control Number 91-023 • FILE Gary L. VanDusen, Mayor January 31, 1991 Re: Associated Grocers - 3301 South Norfolk Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) (UFC 10-1 (3-1)) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC 10.301) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) Exit doors shall swing in the direction of exit travel when serving an occupant load of 50 or more. (UBC 3304(b)) Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). 3. All modifications to sprinkler systems shall have the written approval of the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528) LOGC:�WILA J W /9 09 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Page number 2 Gary L. VanDusen, Mayor (NFPA 13, 1-9.1) (UFC 10.307) Please have the protective caps on the Fire Department Connection replaced. (UFC 10.302(a)) NFPA 14.5-6.7 and NFPA 24.2_6.8) )) (NFPA 13.2-7.6.2, 4. All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NEC 70) (UFC 85.101) All electrical wiring is to be inspected by the State Electrical Inspector, Washington State Department of Labor & Industries. (NEC 70) 5. When fire dampers are required to maintain fire resistance of construction, fire dampers shall comply with the requirements of UBC Standard 43-7. (UFC 10.401) A11 interior wall covering materials shall be fire -resistive or shall be treated to be fire -resistive, so as to result in a flame -spread required b rating as re rah q y UFC Appendix VI -C tables 42A and A certificate of the flame spread rating is required to be delivered to the Tukwila Fire Department. (UBC 4204) (UFC 10.401) There shall be no enclosed usable space under stairways in an exit enclosure, nor shall the open spaCe under such stairways be used for any purpose. (UBC 3309-F) (UFC 12.109c) This review limited to speculative tenant space only - special fire permits may be necessary detailed description of intended use I�pending on City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Fire Department Review Control Number 90-527 • FILA Gary L. VanDusen, Mayor December 28, 1990 Re: Associated Grocers - 3301 South Norfolk Street Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4-3.1) In double row racks, provide a minimum 6" longitudinal flue space in addition to the transverse flue spaces. 2. Refrain from blocking sprinker coverage with shelving. NFPA Standard #13 states that any shelving or decks in excess of 4 feet in width will require the installation of sprinklers thereunder. (UFC 10.302) 3. Storage of Class III & IV commodities, up through 20 feet high, encapsulated in plastic, requires a minimum of 1 level of in -rack sprinklers. Storage of any class of commodity, over 20 feet high, encapsulated in plastic, requires a minimum of 1 level of in -rack spr i nk 1 erscr.ijj G1 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Fire Department Review Control Number 90-491 (512) FILE usen, Mayor December 4, 1990 Re: Associated Grocers - 3301 South Norfolk Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The storage rack system submitted indicates rack shelving in some places up to 16' in width with no flue spaces. Per N.F.P.A. 231C flue spaces are required every 4' to 6' unless in -rack sprinklers are provided, in which case 15' is the maximum width of shelving. Storage of high -piled combustible stock on racks in excess of 12' requires a high -piled storage permit. An application is included. Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd Citylf Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Fire Department Review Control Number 90-311 (512) Gary L. VanDusen, Mayor August 30, 1990 Re: Associated Grocers - 3301 South Norfolk Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) (UFC 10-1 (3-1)) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1-6.6), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1-6.6) (UFC 10.301) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC 10.301) 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3302(d)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) Exit hardware and marking must meet the requirements • City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 • Gary L. VanDusen, Mayor Page number 2 of Uniform Fire Code Sections 12.104 & 10.402(a). Exit signs shall be installed at required exit doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with a minimum letter width of 3/4". (UBC 3314) (UFC 12.108) Exits shall be illuminated at any time the building is occupied. An emergency system shall automatically provide exit illumination upon failure of the main power supply. (UFC 12.107(a)(b)) 3. All modifications to sprinkler systems shall have the written approval of the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528) (NFPA 13, 1-9.1) (UFC 10.307) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1-9.1) (UFC 10.305) Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4-1.1.1) (UFC 10.302) All control, drain, test and alarm valves shall be provided with identification signs of the standard design adopted by the automatic sprinkler industry. Install the following (NFPA 13, 3-14.3) (UFC 10.301) All new underground piping shall be tested • City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Page number 3 Gary L. VanDusen, Mayor hydrostatically. Test pressure shall be not less than 200 psi for 2 hours. Maximum leakage allowed (with joints in plain view) shall not exceed 2 quarts per hour. The Fire Department shall witness all tests. (NFPA 24, 8-9.3.2 & NFPA 24, 8-9.3.3) (UFC 10.301) All underground piping shall be visually inspected by the Tukwila Fire Department prior to any backfilling. Pipe joints shall not be covered until after completion of a successful hydrostatic test. (NFPA 24, 8-9.3.4) (UFC 10.301(f)) Contact the Tukwila Fire Department, Fire Prevention Bureau to witness all required inspections and tests. (NFPA 13, 1-10.2) (UFC 10.305(b)) Local U.L. Central Station Supervision is required. (UFC 14.105) 4. All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NEC 70) (UFC 85.101) Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Fire Department Review Control Number 90-057M FILE Gary L. VanDusen, Mayor April 26, 1990 Re: Associated Grocers - 3301 South Norfolk Dear sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. HVAC units rated at 2,000 cfm or larger are required to have auto shut down devices. These devices shall be separately zoned in the alarm panel and local U.L. Central Station supervision is required. Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau �C Z cc: T.F.D. file ncd City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Fire Department Review Control Number 90-118 Re: Associated Grocers - Dear Sir: Gary L. VanDusen, Mayor April 20, 1990 South Norfolk The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "A11 Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) (UFC 10-1 (3-1)) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinents, or set on shelves (NFPA 10, 1-6.6), and shall be installed so that the top of the extinguisher is not more than 5 ft. above the floor. (NFPA 10, 1-6.6) (UFC 10.301) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC 10.301) 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3302(d)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) 3. A11 modifications to sprinkler systems shall have the written approval of the Washington Survey & Rating Bureau, *ILA ▪ 1908 City of Tukwila FIRE DEPARTMENT O 444 Andover Park East O Tukwila, Washington 98188-7661 (206) 575-4404 Gary L. VanDusen, Mayor Page number 2 Factory Mutual Engineering or Industrial Risk Insurers, then by the Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528) (NFPA 13, 1-9.1) (UFC 10.307) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1-9.1) (UFC 10.305) Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4-1.1.1) (UFC 10.302) Contact the Tukwila Fire Department, Fire Prevention Bureau to witness all required inspections and tests. (NFPA 13, 1-10.2) (UFC 10.305(b)) 4. A11 electrical wiring is to be inspected by the State Electrical Inspector, Washington State Department of Labor & Industries. (NEC 70) All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NEC 70) (UFC 85.101) 5. A11 required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 10.208) City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Page number 3 Gary L. VanDusen, Mayor adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Fire Department Review Control Number 89-442 (512) FILE Gary L. VanDusen, Mayor January 11, 1990 1/01 Re: Associated Grocers - 3301 South No olk 1 Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) (UFC 10-1 (3-1)) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinents, or set on shelves (NFPA 10, 1-6.6), and shall be installed so that the top of the extinguisher is not more than 5 ft. above the floor. (NFPA 10, 1-6.6) (UFC 10.301) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1-6.3) (UFC 10.301) 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3302(d)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) 3. All modifications to sprinkler systems shall have the City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Page number 2 Gary L. VanDusen, Mayor written approval of the Washington Surveying & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1141) (NFPA 13, 1-9.1) (UFC 10.307) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Surveying & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1141 & NFPA 13, 1-9.1) (UFC 10.307) Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4-1.1.1) (UFC 10.302) Contact the Tukwila Fire Department, Fire Prevention Bureau to witness all required inspections and tests. (NFPA 13, 1-10.2) (UFC 10.307) 4. All electrical wiring is to be inspected by the State Electrical Inspector, Washington State Department of Labor & Industries. (UGC 10.104) All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) (UFC 10.104) 5. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 10.208) City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Page number 3 Gary L. VanDusen, Mayor Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd Nicole Hale From: Ben Hayman Sent: Thursday, July 9, 2020 7:05 AM To: Nicole Hale Subject: FW: Web Meeting with Tukwila Fire Marshal's Office Attachments: 2020-07-08 WOW Logistics Commodity - HPS Report - Tukwila WA.pdf Nicole, Please print this out and put it in the business file for 10430 E Marginal Way S. Also, please enter into TRAKIT as an impaired system and attach the file. They will also be issued a Fire Watch today, so you should be receiving that form soon. Thanks, Ben From: Tim Koetje <tkoetje@hansen-rice.com> Sent: Thursday, July 9, 2020 06:23 To: Ben Hayman <Ben.Hayman@TukwilaWA.gov>; Al Metzler <AI.Metzler@TukwilaWA.gov> Cc: Clemens, David <David.Clemens@darigold.com>; Scacco, Rob <Rob.Scacco@darigold.com>; Jake Maxwell (jmaxwell@prologis.com) <jmaxwell@prologis.com> Subject: RE: Web Meeting with Tukwila Fire Marshal's Office Ben & Al, here is the fire protection engineering report for the 10430 facility. We will review this morning. Tim Koetje mobile: (208) 590-8658 Original Appointment From: Ben Hayman <Ben.Hayman@TukwilaWA.Bov> Sent: Wednesday, July 8, 2020 10:59 To: Ben Hayman; Al Metzler; Tim Koetje Cc: Clemens, David Subject: Web Meeting with Tukwila Fire Marshal's Office When: Thursday, July 9, 2020 8:00-8:45 (UTC -08:00) Pacific Time (US & Canada). Where: Microsoft Teams Meeting Meeting to discuss Fire requirements for the Darigold project. Staff from Tukwila Fire Marshal's Office and H & R/Darigold. Join Microsoft Teams Meeting +1 253-292-9750 United States, Tacoma (Toll) Conference ID: 658 313 866# Local numbers I Reset PINI Learn more about Teams I Meeting options 1 THE FIRE PROTECTION INTERNATIONAL CONSORTIUM, INC. FIRE PROTECTION - LIFE SAFETY - CODE CONSULTING SECURITY - PERFORMANCE BASED DESIGN htto://www.the-fpi.com July 8, 2020 Tim Koetje Hansen -Rice Reference: WOW Logistics 10430 E Marginal Way S. Tukwila, WA 98168 High Piled Storage Dear Mr. Koetje: In response to your request we have reviewed the proposed storage arrangement, protection systems, and commodities to be stored in the above facility with regard to commodity classifications and required fire sprinkler design criteria. This review is based on the requirements of the Tukwila Municipal Code adoption of the 2015 International Fire Code and NFPA 13, 2019 edition. WOW Logistics plans to occupy this existing facility and associated warehouse/cooler spaces. The building's sprinkler systems were previously supplied by an onsite pump and tank and connection to the public watermain in S. Norfolk Street, south of the King County Airport and at the far north end of this site. The pump and tank are being demolished as a part of the current site redevelopment and are now out -of -service. The contractor has noted that a new connection to the public watermain in E. Marginal Way S is planned which will then provide the water supply for the fire sprinkler systems in this warehouse. This new connection has not yet been installed. International Region Gerald Schultz, P.E. P-630-985-3106 j.schultz@the-fpi.com West Region Carl Anderson, P.E. P-360-878-9267 c.anderson@the-fpi.com Central/East Region Corey Kinsman P.E. P-630-985-3106 corey@the-fpi.com The Fire Protection International Consortium, Inc. July 8, 2020 Potential for Temporary Occupancy: Based on our review of the available documents and a walk through of the sate to observe existing conditions we find that: 1) In our opinion it would be not be appropriate at this time to allow for temporary occupancy (TCO) of the Ambient Storage Area (plan west from grid line 34 to 41) as proposed by the client until the site water supply deficiencies have been corrected and the sprinkler systems serving that area have been hydraulically re -calculated to account for a current flow test. 2) In our opinion it would not be appropriate to allow for occupancy of the 34F Cold Storage area for rack storage (high piled storage) or the ambient storage to plan east (grid line 1 — 14) until the fire sprinkler system is recalculated based on the new water supply and all necessary modifications are made, fire alarm is installed and other high piled storage items are approved by the City. 3) If approved by the City, temporary occupancy of the office space might be considered as there is not a significant fuel loading introduced based on use of the offices. Existing Sprinkler Systems: The building is protected by 16 existing fire sprinkler systems. 4 of the existing systems previously supplied in -rack sprinklers and/or occupant use (Class II) standpipe hose reels. Those 4 systems are out -of -service. There are no storage racks currently installed in the building and standpipe hose reels have been removed. As on my site visit on July 1, 2020 there was no storage in the building. Various portions of the system have been redesigned/calculated to address changes in commodities and storage arrangement over time. There are no fire sprinkler drawings detailing the existing systems available for review. Based on the information found on-site the existing systems can be described as: System 30: Riser at approximately grid line A-1. Wet pipe system. Previously calculated to 0.24GPM/3,000sf. Exterior yard PIV labeled "V" is located just outside the building at Grid A-1. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 31: Riser at approximately grid line A-1. Wet system. Serves a portion of loading lock at NE comer of building from grid line 12 north of grid line A to grid A-1. Exterior yard PIV labeled "V" is located just outside the building at Grid A-1. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 31A (two risers are labeled 31): Riser at approximately grid line A-1. Out -of -service. This system previously served in -rack sprinklers. Exterior yard PIV labeled "V" is located just outside the building at Grid A-1. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. WOW Logistics 10430 E Marginal Way S 2 Tukwila, WA The Fire Protection International Consortium, Inc. July 8, 2020 System 32: Riser at approximately grid line A-12. Wet pipe system, gridded. Previously calculated to 0.24GPM/3,000sf. Protects east side of warehouse from approximately grid line B- 1 to H-8 and part of the loading dock area. Exterior yard PIV labeled "V" is located just outside the building at Grid A-1. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 33: Riser at approximately grid line A-12. Out -of -service. This system previously served in -rack sprinklers. Exterior yard PIV labeled "WW" is located just outside the building at Grid A- 12. Exterior yard PIV labeled "WW' is located just outside the building at Grid A-12. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 34: Riser at approximately grid line A-12. Dry pipe system. Previously calculated to provide 0.24GPM/3,900sf. Protects portion of warehouse from approximately grid line B-14 to H-8 and part of the loading dock area. Exterior yard PIV labeled "WW' is located just outside the building at Grid A-12. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 35: Riser at approximately grid line A-12. Wet pipe system. No hydraulic calculation data available. Protects portion of offices north of grid line A from A-12 to A-20. Exterior yard PIV labeled "WW" is located just outside the building at Grid A-12. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 36: Riser at approximately grid line A-20. Dry pipe system. Protects portion of loading dock near offices and portion of offices. Exterior yard PIV labeled "XX" is located just outside the building at Grid A-20. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 37: Riser at approximately grid line A-20. Out -of -service. This system previously served in -rack sprinklers. Exterior yard PIV labeled "XX" is located just outside the building at Grid A- 20. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 38: Riser at approximately grid line A-20. Preaction system. Pipe is gridded. Previously calculated to 0.65GPM/2000sf. Systems 38 and 39 serve previous freezer which will be 34F cold storage for new use from grid A-28 to H-16. A gridded preaction system is not allowed under current editions of NFPA 13. This was previously allowed under older editions of NFPA 13. Exterior yard PIV labeled "XX" is located just outside the building at Grid A-20. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 39: Riser at approximately grid line A-20. Preaction system. Pipe is gridded. Previously calculated to 0.65GPM/2000sf. Systems 38 and 39 serve previous freezer which will be 34F cold storage for new use from grid A-28 to H-16. A gridded preaction system is not allowed under current editions of NFPA 13. This was previously allowed under older editions of NFPA 13. Exterior yard PIV labeled "XX" is located just outside the building at Grid A-20. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. WOW Logistics 10430 E Marginal Way S 3 Tukwila, WA The Fire Protection International Consortium, Inc. July 8, 2020 System 40: Riser at approximately grid line A-34. Out -of -service. This system previously served in -rack sprinklers. Exterior yard PIV labeled "Y" is located just outside the buiding at Grid A-34. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 41: Riser at approximately grid line A-34. Riser at approximately grid line A-34. Dry pipe system. No previous hydraulic calculation data shown on the riser. Served previous cooler at grid lines A-41 to G-34 on the west side of the building. The system piping is gridded. A gridded dry pipe system is not allowed under current editions of NFPA 13. This was previously allowed under older editions of NFPA 13. Exterior yard PIV labeled "Y" is located just outside the building at Grid A-34. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 42: Riser at approximately grid line A-34. Dry pipe system. No previous hydraulic calculation data shown on the riser. Served previous cooler at grid lines A-4 t to G-34 on the west side of the building. The system piping is gridded. A gridded dry pipe system is not allowed under current editions of NFPA 13. This was previously allowed under older editions of NFPA 13. Exterior yard PIV labeled "Y" is located just outside the building at Grid A-34. FDC is located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street. System 43: Riser at approximately grid line J-28. Dry pipe system previously calculated to 0.54GPM/2,600sf to serve previous cooler at grid lines J-28 to G-41 in the SW comer of the building. This will be part of the new ambient temperature storage area. Exterior yard PIV labeled "Z" is located just outside the building near Grid J-28. FDC is located on the riser room wall near grid line J-28. This FDC serves only systems 43 and 44. The site FDC located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street appears to also serve systems 43 and 44 since it appears to serve a site underground main that loops the building. However, there is not a detailed site utility as -built drawing available to confirm that the loop main encircles the entire building. System 44: Riser at approximately grid line J-28. Dry pipe system previously calculated to 0.54GPM/2,600sf to serve previous freezer at grid lines H-28 to K-16 on the south side of the building. This will be part of the new 34F cold storage area. Exterior yard PIV labeled "Z" is located just outside the building near Grid J-28. FDC is located on the riser room wall near grid line J-28. This FDC serves only systems 43 and 44. The site FDC located on the face of the 'hotbox' enclosure for the site backflow preventor just inside the gate along S. Norfolk Street appears to also serve systems 43 and 44 since it appears to serve a site underground main that loops the building. However, there is not a detailed site utility as -built drawing available to confirm that the loop main encircles the entire building. When any improvements are made to these system, seismic bracing will need to be brought up to current standards per Tukwila Fire Marshal requirements. Commodity Classifications: 34F Cold Storage Based on the information provided by the client for our review as of July 6, 2020 the commodity classification for the 34F Cold Storage Cooler from grid line A-34 to south of J-16 WOW Logistics 10430 E Marginal Way S 4 Tukwila, WA The Fire Protection International Consortium, Inc. July 8, 2020 will be: Milk: Plastic jugs in gridded plastic milk crates. Class I commodity plastic based on 2019 NFPA 13, Table A.20.4.1 for milk in plastic bottles up to 5 -gallon capacity. Milk jugs are then placed in open gridded milk crates. NFPA 13 does not specifically list milk in gridded plastic milk crates for commodity class. Referring to FM Global Data Sheet 8-1, we see that the can best be classified as a Class I commodity. 8-1 Commodity Classification Page 12 FM Global Property Loss Prevention Data Sheets Item Calegay Matey) Class 85 Non -Ignitable Liquids Metal cans Med with non -ignitable (quids or semi-solids, stored on cardboard trays, n carton, or on Slipsheets (dividers): no plastic components (except plastic sheet wrap or banding) Class 1 86 Non -Ignitable Non -ignitable (quids in plastic containers that hold 5 gal (19 L) or Liquids less Class 1 87 Non -Ignitable Semi -liquids (non -ignitable), including crushed holt and Liquids vegetables, stored in solid plastic containers that told 5 gal (19 L) or less Class 1 88 Non -Ignitable I Glass bottles or )ars filled with non -ignitable liquids. Liquids ' stored in gndded plastic containers Class 1 89 Non-nifagie Liquids ' Plastic bottles, filled with non -ignitable liquid, stored in gridded plastic containers Class 1 '< 90 Non -Ignitable Liquids Polyethylene Terepht slate (PET) bottles Med we non -ignitable liquid, stored In gilded plastic containers Class 1 i 91 Non -Ignitable Liquids Cardboard dnlc boxes (plastic -coated, wax -mated, and/or aluminum -lined) tilled with non -ignitable liquid. cartoned Class 2 Table 1 Products Stored in Plastic Containers General Contents Container Sides and/or Bottoms Wall Thickness in. (mm) Volume gal (L) Descnpbon of Contents Commodity Classification Solid or gridded Solids Any > 1 (4) Noncombustible UUP = 1 (4) Noncombustible CUP Any Combustible UUP or a lesser hazard UUP Any UEP commodities UEP Liquids or Semi- Liquids Gridded Any Any Bottles or jars containing nonignitable liquids/semi- liquids Class 1 Solid Any Any Bottles or )ars containing nonigirtable liquids/semi- liquids UUP <_ 5 (19) Nonignitable liquids/semi-liquids Class 1 > 1/4 (6) > 5 (19) Nonignitable Iiquids/serni-liquids UUP < 1/4 (6) . 5 (19) Nonignitable liquids/semi-liquids Class 2 WOW Logistics 10430 E Marginal Way S 5 Tukwila, WA The Fire Protection International Consortium, Inc. July 8, 2020 Milk: Jugs/cartons in cardboard cartons, wooden pallets, banded. Class I commodity, non - encapsulated based on 2019 NFPA 13, Table A.20.4(b). Butter/Margarine: Butter and margarine up to 50% oil. Class III commodity based on 2019 NFPA 13 Table A.20.4(b). These commodities are stored on wooden pallets, banded but not encapsulated. Margarine: Margarine over 50% up to 80% oil would be considered a Non -expanded Group A plastic commodity, exposed based on 2019 NFPA 13 Table A.20.4(b). Based on the WOW Logistics 6 10430 E Marginal Way S Tukwila, WA The Fire Protection International Consortium, Inc. July 8, 2020 information we have been provided for review as of the date of preparing this report, none of the margarine products will exceed 50% oil. Cottage Cheese/Cultures: Plastic containers, exposed. Not specifically listed in NFPA 13. Compare to milk in plastic jugs. Class I commodity, non -encapsulated based on 2019 NFPA 13, Table A.20.4(b). Based on the above the worst-case commodity for the 34F cold storage area will be Class III, non -encapsulated. This may change if more information of other commodities is received or if margarine over 50% oil is to be stored. Fire sprinkler design for the new 34F Cold Storage Area will need to be based upon this classification. It appears that the cooler area is currently protected by sprinkler system risers 38, 39, 41, 43, 44. Client's fire sprinkler contractor will need to survey existing system for pipe sizes and recalculate the roof level protection to determine available hydraulic design criteria. Once the roof level sprinkler capacity has been determined, use NFPA 13 Chapter 16 to determine necessary in -rack sprinklers and/or roof level sprinkler system redesign to accommodate the new storage height of approximately 31ft on double and multiple row racks (less than 16ft deep) with aisles exceeding 8ft. Dry Storage (Ambient): This area houses general dry goods including a variety of food products. Storage will be on the floor, up to 2 pallet loads high with maximum storage height of 12ft based on the information provided for our review as of July 8, 2020. Detailed information on the future commodities has not been provided; therefore, the commodity classification will need to be determined prior to determining the required fire sprinkler design criteria. WOW Logistics 10430 E Marginal Way S 7 Tukwila, WA The Fire Protection International Consortium, Inc. July 8, 2020 In the near term, bagged protein powder on wooden pallets, encapsulated, are planned for the ambient storage area from grid A-41 to grid J-34. This commodity class would be Class III based on dry foods, bagged, per NFPA 13 Table A.20.4(b). From NFPA 13, Table 4.3.1.7.1 this results in a minimum OH2 design criteria for up to 12ft of storage height. IFC Chapter 32 High Piled Storage Compliance Issues: Useable Height: Racks for high piled storage will be installed in the coolers. Maximum storage heights in the coolers will be 31ft with underside of the roof at 40ft (35'-6") or less. The roof/ceiling height varies slightly with 35'-6" peak measured in the coolers. Tiers: Racks in the cooler will have 5, 4, 4 and 3 tiers in the Type 1, 2, 3 and 4 racks, respectively. Clearance to Sprinklers: Based on control mode density area sprinklers (existing) a minimum of 18" clearance is required. Aisles: Aisles in the high piled storage areas on the coolers all exceed 8ft in width Pile Volumes: Future high -piled storage, palletized on the floor up to 2 pallets (12ft maximum) top of storage is planned for the ambient areas. Detailed storage plans showing pile height, length, width and aisles to exits will be required. For Class I-IV commodities this will not be considered high -piled storage. Location and Classification of Commodities: The various commodities listed above can be found throughout the racks in the cooler. The fire sprinkler system will be designed for the worst-case commodity classification as noted above. (Class III, non -encapsulated based on current information — pending additional details). Location of Commodities that are Banded or Encapsulated: No encapsulated commodities are proposed in the racks. Banded commodities can be found in any of the racks in the coolers. The protein powders in the ambient storage space (Grid A-41 to J-34) will be encapsulated based on the information provided for our review. WOW Logistics 10430 E Marginal Way S 8 Tukwila, WA The Fire Protection International Consortium, Inc. 14— i 1 r.41.i G rpnnn -nnnnnnon .Irt All ccrmmnditirc to he stoied in racking e'' ' , r' -c -- r r _I Y_ II III I1 fl 1' 11 11111 1 11 1 11 1 11 1 11 1 T MSS _umr^-dims - JLu er'[li 'et will be rr fixed wrhir `his Jr=a. — % rased l'rc.iJ:.t will :.'.?rflcw hefts Ical cr rackir •w 111 1'11 111 1'11 L t 111 1111 111 111 1111 111 111 111 Uil IU 111 III 1111 111 Ili III 1111 III III 111 1111 111 111 0:i 0]00 006 L']0 li 111 1 ii 111 Fire Fighter Access Doors: — .17 a-.1= r- of adI 1 1 v. `irr:=I July 8, 2020 High -piled storage is not proposed for the "Ambient" storage areas; therefore, IFC 3206.6.1 does not apply to these areas: The ambient area from grid A-41 to J-34 has existing doors in the north and south exterior walls as shown on the Hansen -Rice drawings. There are no doors in the west wall. The ambient area from grid A-14 to grid H-1 has existing doors in the east, north and south exterior walls as shown on the Hansen -Rice drawings. The 34F cold storage coolers will by high piled storage. Portions of the north and south exterior walls give access to the cold storage area. The spacing of the existing doors varies and is roughly 130ft — 150ft on -center. This exceeds 100ft; however, IFC 3206.6.1.1 allows the existing door spacing to remain since the occupancy of the building is not changing. Further, once adopted the 2018 IFC will allow up to 200ft door spacing for existing buildings. Approval of existing space is at the discretion of the fire marshal. WOW Logistics 10430 E Marginal Way S 9 Tukwila, WA The Fire Protection International Consortium, Inc. July 8, 2020 Fire Sprinkler Criteria: Please see the more detailed discussion above. For the cooler, design is to be based on minimum Class III non -encapsulated on double and multiple row racks (up to 16ft deep). This may change if more information of other commodities is received or if margarine over 50% oil is to be stored. Maximum 12ft high floor storage is planned for the ambient areas. More detailed information is needed for commodity classification. However, for Class 1-111 up to 12ft and for Class IV commodities up to 10ft, and OH2 design is appropriate per NFPA 13, Table 4.3.1.7.1. Fire Alarm: Fire Alarm shall be provided under separate permit and comply with City of Tukwila requirements. Valve Locations: See the detailed description above for location of yard PIV's and interior riser control valves. Smoke and Heat Vents and Curtain Boards: 34F Cold Storage Area: The 34F Cold Storage Area is approximately 129,755sf. Roof/ceiling height is 35'-6". Based on IFC Chapter 9, the required area of smoke vent will be 129,755x35.5/9000 = 512sf. This equates to 512/32= 16 typical 4'x8' smoke vents. There are no existing smoke vents. Curtain boards are not required per Table 3206.2 Mechanical smoke exhaust is allowed rather than typical smoke vents based on a minimum of 2 air changes per hour for the volume of the space. This its a detailed mechanical design following IBC and IFC Section 910.4 and is beyond the scope of this report. Ambient Area Grid A-41 to Grid J-34: No high piled storage is proposed for this area. Ambient Area Approximately Grid A-14 to Grid H-1: No high piled storage is proposed for this area. Flues: Racks, when installed, will need to provided flues in accordance with the 2015 IFC and 2019 NFPA 13. 6" transverse flues will be required at maximum 5ft intervals in the double and multiple row racks. 6" longitudinal flues will also be required in the double row rack. WOW Logistics 10430 E Marginal Way S 10 Tukwila, WA The Fire Protection International Consortium, Inc. July 8, 2020 Aisles: All aisles exceed 8ft in the high piled rack area. Site Access: Paved fire apparatus access is provided on the north and east sides of the building as well as a portion of the south side. The remaining portion of the south side is a gravel access road. The west end of the building fronts on East Marginal Way South with a fence between the street and the building. WOW Logistics 10430 E Marginal Way S 11 Tukwila, WA The Fire Protection International Consortium, Inc. July 8, 2020 Site Fire Flow: Currently there is an existing on-site water main looping this building. Pipe diameter is unknown at this time but is believed to be at least 10" diameter. This loop is fed via a 10" underground main from the north end of the site via a connection to the city main in S Norfolk Street. Flow testing conducted on 7/7/2020 indicated a significant drop in pressure when a hydrant near the building was partially opened. This is indicative of a blocked pipe or nearly closed valve somewhere in the main. Static pressure of 138psi dropped quickly to 7psi with the hydrant only partially open. Other hydrants were found to be in a state of disrepair with leaking at the bonnet when partially open and with significant rust on flange bolts. If more information is needed, please do not hesitate to contact me. Sincerely, Carl Anderson, PE The Fire Protection International Consortium, Inc. Digitally signed by Carl Carl Anderson, PE Anderson, PE Date: 2020.07.08 16:27:20 -07'00' WOW Logistics 10430 E Marginal Way S 12 Tukwila, WA 5/S SMITH FIRE SYSTEMS, INC. 4106 136th Street NE • Marysville, Washington 98271 (360) 651-7701 • FAX (360) 651-2419 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME UNIFIED GROCERS JOB NO. TI9194 DATE 11/30/09 ADDRESS 10430 E MARGINAL WAY BY MATTHEW GILBERT TUKWILA, WA 98168 SYSTEM DESIGNATION: 1 HAZARD DESCRIPTION: ORDINARY HAZARD GROUP 2 HAZARD CLASS PER NFPA 13 : 2007 SPECIFIC RULING: RULING MADE BY: OF DENSITY: .20 GPM OVER THE MOST HYDRAULICALLY REMOTE 184 SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: INSIDE HOSE 0 GPM OUTSIDE HOSE GPM IN -RACK SPRINKLER DEMAND N/A GPM SYSTEM TYPE: WET "C" FACTOR OVERHEAD : 120 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: SPRINKLER MANUFACTURER: RELIABLE MODEL: K -FACTOR: TOTAL NUMBER OF SPRINKLERS THIS SYSTEM "C" FACTOR UNDERGROUND : 130 SQUARE FEET F1FR TEMPERATURE: 200 ° F 5.6 ORIFICE SIZE: N/A WATER SUPPLY: STATIC 120 PSI RESIDUAL 84 PSI FLOW 292 GPM ELEVATION OF TEST: DATE OF TEST: DATA PROVIDED BY: LOCATION OF TEST: 16' ABOVE FLOOR RISER PLACARD BASE OF RISER BASE OF RISER DEMAND 56.30 GPM REQUIRED AT 40.5 PSI (INCLUDING 0 GPM FOR HOSE STREAMS) lgZIMMICIiI•II:10 1' IA 1c1:[c I TIIW_X 1TIV114:1:1117g4111TWO ie Ix T[ l_1_ :[•Isl , a a a O U w I_F. xi7 7 : cn 1- w 0 0 ccx 0 I0 et a Q O ■ ■ ■■■■■■■n1■■ .■■ ■ ■■■p .. ■ ■ ■ ■ ■ ■ w 1 .■ ■i 1n1 • ..1.1 _ '11...1■1na 1■. 6 L111 8•.:•.••' • • n':1 u11111: Rim _ _ ■ ..•111111011: _ , _•i 1u .1.. 6 u ■. u6 I.i u ■■..111..1.... ■...■. •.6. ■.... ■ 161....1■ 1.1 - .. 1;1 ■ 1 11 1.a■ . :1 : _• __ .- 11II ''161 ■6■ ■n■ ... . 1.■ ■ ■ - 11■■.61m1'• ...6. _ _ 111 . u■ ■■ •■ ■■ ip 111111.6 661 6ppa■ 16 1111g •. 1. . 1111 1 11111/111 aid111 gg _ _ la Il lli III .. _ ...n... .. o ....■ i 111:1111112:11 •••u•••••;n. ••• mod a. ..■■aa 1 Ia ■■C.lii 1111:111 • • n• i 'a66. i.aiaaril....6111111. as ., .: ■ Pill ■ ■■■....n■ ■ ■■6_ . ■ i a .. ..■■.■ 1111111 i...........u.. •_ 6 .n.■.■■■.a ag_ •6 66••61: p 6I• nu 6.........a; UIa a6 U.■aC 6 11 1 ■■a a 1 1 6111 i 6 a■ .. ••••U•11.6.....6 = 66 A66 ■ 6 6 ... 66.16.6 Ia 1111111111111111111 1111 ••• 1::1: ■:..i•• ••••a1•• 1111111111111111161111111: • Iallaaaa :a6 UU a a .u: 6 a•aa aha = j •I • 1: aaaaaaa 1111 a a• ■■.n T ••IIII 1.:'' 111 1 u• .. u i::■ i •66 i 1 1u1116 uu■ • 1 1 =11.:....•1 1 -: •1 • = 1 .., •111.1 .■ ..... .. _ _ 111411111 6 •66 1 ..1!66611 .U. 11 . :111.111111111111111111 = i1. . 6 •. 9111111 . 1 i m .n •6 ....;.111 . 6 1.. ii 1 6.11 =a1 666.•16.1 6 .. .. . 1.. C:....s•.1..111 . ••••• 1 _ 111 6. .. 6. _ .66;. •• ■.1... a ■• 6 .. ... .6 1..== C. i. Ua . 1C1 11 O 61111111111 ■ .. 1 II ..■. . ■■■_._ i•ll .a u 1 i 11 i 11111 I 1114111111111111 1411 111 ii ins _ I6 1 !_ 1= 1 III hill 11 ,6 III111, s, s .nIII., ,. .ii,.ai m i11111111111111 1111111111111 u,.i uaiui, .aii iii i - i. ... 6....,,,N.= ,..., ,a uu,.,.. .6 .l,.I . .il ...I logo I. !. . .....1.a... , s.:=::_ .:1 " =:C:::: :: X611==111 _ : II : " , , 1111111 .. ..... . I... 1.6.11.1 m . a .16a. . .la a6... ..h ' .U, a .... .. . . ! . I6.... 16... n■..6...6. 11 ... ..a E. III MINI BM 1111I16IHHHH 1 R 61111111 61 M111111111111111111111 .111 ........... =1 1.111= a6■1 . . 1 010101111.0111001111111101011 01111 u•••.■ a •■ .= SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 12/2/2009S TI\DESIGN\HYDRAULIC CALCS\TI9194 MRA UNIFIED GROCERS.SDF JOB TITLE: WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SC 120.0 84.0 292.0 118.3 56.3 40.5 Required pressure is 77.8 psi (66%) less than available pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 56.3 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 56.3 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 9.0 K= 5.60 9.5 17.2 2 10.5 K= 5.60 10.3 18.0 3 10.5 K= 5.60 14.1 21.0 11 10.0 11.4 - - - 12 10.0 15.5 13 16.5 22.6 21 23.0 37.8 22 28.0 36.1 23 28.0 - - - - 36.2 - - - SC 18.0 SOURCE 40.5 56.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 12/2/2009S TI\DESIGN\HYDRAULIC CALCS\TI9194 MRA UNIFIED GROCERS.SDF JOB TITLE: PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -17.2 1.049 PL 11.33 PF 2.4 1 9.0 5.6 9.5 17.2 6.4 120 FTG 4ET PE -0.4 11 10.0 0.0 11.4 0.0 0.099 TL 24.33 PV Pipe: 2 -18.0 1.049 PL 3.25 PF 0.9 2 10.5 5.6 10.3 18.0 6.7 120 FTG T PE 0.2 11 10.0 0.0 11.4 0.0 0.107 TL 8.25 PV Pipe: 3 -21.0 1.049 PL 3.25 PF 1.2 3 10.5 5.6 14.1 21.0 7.8 120 FTG T PE 0.2 12 10.0 0.0 15.5 0.0 0.143 TL 8.25 PV Pipe: 11 -35.2 1.049 PL 6.00 PF 4.1 11 10.0 0.0 11.4 0.0 13.1 120 FTG T PE 0.0 12 10.0 0.0 15.5 0.0 0.371 TL 11.00 PV Pipe: 12 -56.3 1.380 PL 24.75 PF 9.9 12 10.0 0.0 15.5 0.0 12.1 120 FTG 6E PE -2.8 13 16.5 0.0 22.6 0.0 0.232 TL 42.75 PV Pipe: 13 -56.3 1.380 PL 62.50 PF 18.0 13 16.5 0.0 22.6 0.0 12.1 120 FTG 3ET PE -2.8 21 23.0 0.0 37.8 0.0 0.232 TL 77.50 PV Pipe: 21 -56.3 2.703 PL 37.25 PF 0.5 21 23.0 0.0 37.8 0.0 3.1 120 FTG T PE -2.2 22 28.0 0.0 36.1 0.0 0.009 TL 58.95 PV Pipe: 22 -56.3 4.260 PL 36.50 PF 0.1 22 28.0 0.0 36.1 0.0 1.3 120 FTG T PE 0.0 23 28.0 0.0 36.2 0.0 0.001 TL 67.30 PV Pipe: 23 -56.3 6.357 PL 10.00 PF 0.0 23 28.0 0.0 36.2 0.0 0.6 120 FTG TBA PE 4.3 SC 18.0 SRCE 40.5 (N/A) 0.000 TL 87.80 PV NOTES (HASS): (1) Calculations were performed by the HASS 8.0 computer program under license no. 27081573 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 (2) The system has been calculated to provide an average imbalance at each node of 0.019 gpm and a maximum imbalance at any node of 0.168 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 12/2/2009S TI\DESIGN\HYDRAULIC CALCS\TI9194 MRA UNIFIED GROCERS.SDF JOB TITLE: (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 13.1 ft/sec at pipe 11. (4) PIPE FITTINGS TABLE Pipe Table Name: SMITH.PIP PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T F C B G A D X Ell Tee 45 Tee BfyVly GatVly AlmChk DPV1v fleX 4.260 9.00 30.80 4.50 23.00 7.50 2.60 27.70 33.00 0.00 6.357 12.60 44.00 6.30 33.00 6.10 3.80 27.70 32.80 0.00 PAGE: Y MATERIAL: SCH7 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T F C B G A D X Ell Tee 45 ChkV1v BfyVly GatVly AlmChk DPV1v fleX 1.049 2.00 5.00 1.00 5.00 6.00 1.00 0.00 0.00 24.00 1.380 3.00 6.00 1.00 9.00 6.00 1.00 0.00 0.00 0.00 2.703 6.70 21.70 3.40 23.30 5.70 2.00 11.00 11.00 0.00 AVOW! LITEMATIHEE 1104111.1. TRAIMIMG I search I Sammys® for Wood - VERTICAL • METAL FASTENING • SUSPENDED ANCHORING • FLASHINGS • HOLLOW WALL • WALL SYSTEMS • WOOD DECK • MASONRY VFXT.EX5098 - Hangers, Pipe WM."NEW MADE IN D.i1 stun Known as The Original Sammy Super Screws, vertical Sammys for wood provide reduced Installation cos® offer cast -effective Ume savings. Unlike traditional methods of overhead attachments, they require no pre- drilling Into dlmens,Unal lumber and composite wood Joists. UL listings and FM approvals are available. Available in a wide range of fastener lengths far' A', Ve, 'h', end 1.110 threaded rod. ♦\ 0 L J FEATURES • No pre -drilling required. • Structural attachment and rod anchor combined. • Quick to Install using the appropriate Sammy Nut Driver with an 1BV cordless drill/driver. • Reduces Installation cost. • Made In the U.S.A. • Page 2 of 2 SWG20 1-1/2 3/8 3 Self -threading anchor for horizontal Installation Into the side of a wood timber or joist SWG20-SS 1-1/2 3/8 3-1/2 Self -threading anchor for horizontal installation into the side of a wood Umber or joist SWG20 1-1/2 3/8 2-1/2 Self -threading anchor for horizontal Installation Into the top chard or Flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 M. size SWG20-SS 1-1/2 3/8 2-1/2 Self -threading anchor for horizontal Installation Into the top chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 In. size SWG25-380 1-1/2 3/8 3-1/2 Self -threading anchor for horizontal Installation into the top chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 In. size GST 25-380 1-1/2 3/8 4 Self -threading anchor for vertical Installation Into the bottom of a wood timber or joist GST 30 1-1/2 3/8 4 Self -threading anchor for vertical installation Into the bottom of a wood timber or joist GST 30 -SS 1-1/2 3/8 4 Self -threading anchor for vertical Installation Into the bottom of a wood timber or joist SH-GST30 1-1/2 3/8 4 Self -threading anchor for vertical installation into the bottom of a wood timber or joist SH-G5T30- 5S 1-1/2 3/8 4 Self -threading anchor for vertical Installation Into the bottom of a wood timber or joist GST 20 1-1/2 3/8 2-1/2 Self -threading anchor for vertical installation Into the bottom of a wood timber or joist GST 20.55 1-1/2 3/8 2-1/2 Self -threading anchor for vertical Installation Into the bottom of a wood timber or joist SH-G0T20 1-1/2 3/8 3 Self -threading anchor for vertical Installation Into the bottom of a wood timber or joist SH-GST20- SS 1-1/2 3/8 3 Self -threading anchor for vertical installation into the bottom of a wood timber or joist GST 25-380 1-1/2 3/8 4 Self -threading anchor for vertcal installation Into the bottom chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 in. size GST 20 1-1/2 3/8 2-1/2 Self -threading anchor tor vertical Installation Into the bottom chord or flange of a structural composite wood Joist of minimum 1-1/2 by 1-1/2 In. size GST 20-5S 1-1/2 3/8 2-1/2 Self -threading anchor for vertical Installation Into the bottom chord or flange of a structural composite wood joist of minimum 1-1/2 by 1-1/2 In. size 51-1-05T/ CST 20 1-1/2 3/8 4 Threaded anchor for installation Into wood, 1.5 In. nominal thickness that is horizontal SH -GST/ CST 20 1-1/2 3/8 2-1/2 Threaded anchor for Installation Into wood, 1.5 in. nominal thickness that Is up to 45 degrees from horizontal • NPS - Nominal pipe size Trademark and/or Tradename: `Truss -T Hanger' Last Updated on 2010-12-13 Iz - o INCORPORATED CORONA, CA (909)737-5599 Fig. 2 Adjustable Band Hanger t® Fig. 2 NFPA Adjustable Band Hanger With Reduced -Rod Size Range —21/2 thru 6 inch pipe. Material—Carbon Steel, Pre -Galvanized. Function— Recommended for the suspension of non - insulated pipe or insulated pipe with Fig.220 shield Fjg.2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet #13. Approvals—Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Federal Specification WW -H-171 E, type 10, and Manufacturers Standardization Society SP -69, type 10. Finish— Pre -Galvanized Note—Available in Stainless Steel materials. Order By — Figure number, pipe size, and material. PIPE ROD SIZE SIZE 2 1/2 1/2" 3 112' 3 1/2 1/2' 4 5/80 5 5/8•' 6 3/4— A B C 5-3/4 4-1/4 6 4-1/8 7-3/8 5-1/4 7-3/8 5 9 6-1/8 9-3/8 6-1/2 3/8" nut is used when NFPA rod sizing is requested. 1/2" nut is used when NFPA rod sizing is requested. 0 tb a L, t oft -yrs (-rp) 411- 6"x • 1- 4-b -6 .».. : 3x--3 • Without Comments L ANoted in Red IF Per The Attached Letter r -r€ e plans have been reviewed by The Tukwila Fire entioq Bureau for conformance with current City >lwar+is. Acceptance is subject to errors and J't.;;ions which do not i.iutr orize violation= of adopted (',dards and ordiilarlc`:i. T hz responwih•i.ity for the ..i rqjar y of design {fi.h the I t,'c`ner. d tiorts/ deiet;or-i_ r visic,ns to t i s-,. drF,i ings after +iiJ date will void itis and > require _-utie a resubmit -al of revi.3 fi unit:,, i t7i. su *: grit approval. Final acceptan4,:e tc elesd test and inspection by The Tukwila Fire P r ev e: tl.,till Ire'L,res;j. Date: l 1 -Io (t,,. j ' 4' 6' 8' 10' 12' 14' 16' 18' k TUKWILA FIRE DEPARTMENT Please caii 206-575-4407 and give this Fire Pei"mit No. 1/-s-).5 and exact address for shut- down or restoration approval. tfi,rr,.Ac stamps must be i`'.cz-Id:et.r before pipe is -- °JQ Paint piping -i: drostratictt f 1-5/8 1-1/4 2-1/8 1-5/8 2-1/4 1-7/8 MAX. REC. LOAD LBS. 600 600 600 1000 1250 1250 APPROX. WEIGHT/100 FIG. 2 FIG. 2 NFPA 41 40 45 43 52 50 59 56 97 95 139 105 extST1f,46.1 1,2" i ,rn.na..r.r +.c.....,nw..+:yr,rw..w.,.rNwv.w.w-A.._...-.mow.1 '1x Flt€Wait\tkift4NA . a n! m.. b .w.P t'ttAG t5":. T` PtC ,,.: N 1/4 : >... ." .o. ;..:_.• Wt)0 J a (; ST' tt/2 S1PIZL 11.( I tIE-14 1" Frto,1 EXtSt'tt C- New 11. / t' ATR- - STK!. 1-101‘t12._,? tt•lcW t55• tiz` 62R ?EtA 0r4 2,Z, 401 E141J t G. 2.3 -G • SccTlo l/4= k-0 • (tai NCW Y/ET t'E tarts t0 C(o') 1\ W 7Av4 At li\ CO:)(4 S Cr•Pic A C1 ASL 1.1cta PtP8LG To SCA, 4o t" E t' aricut AC' . X" STtvt._ f -t t.L6L 4-10\t.tc 'rI•s. Lets'N•-‘Ni SC Rt. SPRINKLERS UPRIGHT PENDENT tss. y2"& 5.(,K SIDEWALL Phone: 425-403-5657 IN, Fax: 425-403-5077 P.O. BOX 1543 — WOODI?MLLE, WA 98072 E—MAIL' advflrMbom.dla.com FIRE PROTECTION INC. JOB: V,rlt .tE:t Gizocerr5 10430 E L t.-t1RQ61 WWI S . TtAcw►LA , 4A. 01161i6 BY: T: Ztce DATE 11-21- 11 SCALE 1/¢=1-v PIPING PLAN & DETAILS OF i 1 i 1`/ (. .? .- .. }: n.a. I ...—...u!,..*....w......-.rv..-. n-,..ex+,s.-,rv-..,.a+vW.....+.rw-w•,,,,nr•rss -.. a .re..s. ..n- .. a. ...ran.-vr.^v...e M't• f„ ri.w ,iz....... .v ..l .i t 4 i t r I i a.r9n0•1•Iw^"• rvxn, .., .n..tt•,.....-... .^r, xr .. a. ...w .-.... !.... ....,-.-..e. .•. n..m •-e. .: .. .-.r'wr.rMt-. .... .. .t .. .., I. i w. 1.. .., n ... 0- J ...-Yh,c-.,,,, x. rs . x,p-f,..Tvxt'..,,,.•. .....— w...r.✓+..r..w......W 4 .11I rmnvu.•++rn..-+enva»....vw+ PW.µxs-•xnvT+.n. . •.... 41 a ,...........nn - l n.....".ori.ur-rn•w+.ts'..nMw+rf<oY.rl.rwalr!n+MFW.• . 1 ::.nanuP. .r.r.rv.r.-i.w.....v I •.,a+.rs. I I ..; ....M extST1f,46.1 1,2" i ,rn.na..r.r +.c.....,nw..+:yr,rw..w.,.rNwv.w.w-A.._...-.mow.1 '1x Flt€Wait\tkift4NA . a n! m.. b .w.P t'ttAG t5":. T` PtC ,,.: N 1/4 : >... ." .o. ;..:_.• Wt)0 J a (; ST' tt/2 S1PIZL 11.( I tIE-14 1" Frto,1 EXtSt'tt C- New 11. / t' ATR- - STK!. 1-101‘t12._,? tt•lcW t55• tiz` 62R ?EtA 0r4 2,Z, 401 E141J t G. 2.3 -G • SccTlo l/4= k-0 • (tai NCW Y/ET t'E tarts t0 C(o') 1\ W 7Av4 At li\ CO:)(4 S Cr•Pic A C1 ASL 1.1cta PtP8LG To SCA, 4o t" E t' aricut AC' . X" STtvt._ f -t t.L6L 4-10\t.tc 'rI•s. Lets'N•-‘Ni SC Rt. SPRINKLERS UPRIGHT PENDENT tss. y2"& 5.(,K SIDEWALL Phone: 425-403-5657 IN, Fax: 425-403-5077 P.O. BOX 1543 — WOODI?MLLE, WA 98072 E—MAIL' advflrMbom.dla.com FIRE PROTECTION INC. JOB: V,rlt .tE:t Gizocerr5 10430 E L t.-t1RQ61 WWI S . TtAcw►LA , 4A. 01161i6 BY: T: Ztce DATE 11-21- 11 SCALE 1/¢=1-v PIPING PLAN & DETAILS OF PIPE / FITTING LEGEND NEW SPRINKLER PIPE EXISTING SPRINKLER PIPE ► NEW PLUG S NEW STRAP TEE NOTICE.' WALL LEGEND 1 Weld stamps must be inspected before pipe is hung. Dp not paint piping Mor to hydrostatic test pprovaI. EXISTING WALL EXISTING MAIN BUILDING SECTION NTS .70 4 (EXISTING) r 2 EXSTING) UR 0 SPRINKLER PLAN D 4 8 SCALE 1/4'=1'-0' ACCEPTE Er Without Comments 0 As Noted in Red J Per The Attached Letter These pians; have been reviewed by The Tukwila Fire vention Bureau for conformance with current City °-:-ndards. Acceptance is subject to errors and +nasions which do not authorize violations adopted I • .andards and ordinances. The responsibility for the lequacy of design rests totally with the designer. .,-idtions, deletions or revisions to these drawings after, i this date will void this accept nce and will require a resubmittal of revised drawings for subsequent approval 1 -in ;,l acceptance is subject to field test and Inspection byi The Tukwila Fire Prevention Bureau. Date: /c) --7--o GI By.: %51 1' IUt WILA TIRE UEPAKihri1T.i'd Please calf: 575-4407 and give this job Ivo. 09 -S -?o3 ;act address for shut • ;3T Yesuration-aourotral SYM MANUFACTURER S.I.N. TYPE SPRINKLER LEGEND MODEL 114.1413 ser EXISTING NEW REUABLE R3625 SSU F1 FR BRZ 5.61( 1/2' 200' 3 ABBREVIATIONS AFF BOO B00 BOJ BOP BOT C15 F0 IFOW DNAs Ula VITAL ,IyW(W ABOVE FINISHED RDOR 801100 OF BEAM BOTTOM OF DECK BOTTOM OF.0101 BOTTOM OF PNS1N 801108 OF TRUSS CUT TO SUR 00.0 OMEN INSIDE FACE OF WALL OUTSIDE FACE OF WNL NO AUTO. SPWNDER3 UNLESS NOTED OOERV15E SYMBOL LEGEND CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2 -WAY EARTHQUAKE SWAY BRACE LL i ItR INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE LETTER INDICATES TWE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAUUC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPUNG NO. DATE WOOD JOIST 3/8' x 2' LAG SCREW W/ STD. WASHER TOLCO FIG. 58 SIDE BEAM BRACKET 3/8' ATR HANGER RING HANGER DETAIL 'SB' (2) 3/8' x 3' KWIK BOLT ( 21/2' MIN. EMBED ) 3/8'X4'ATRWITH NUT & WASHER SIDE BEAM BRACKET CONCRETE WALL )(4'(' HANGER DETAIL 'WB' TIN STRAP W/ (2) 5/16' x 2-1/2' LAG 2 x 4' x 9' WOOD BLOCK PLYWOOD CEIUNG HANGER DETAIL 'SC' JPIgnmSt > N T !. ° SLl Llano Access Rd • BY AREA MAP NTS CONTRACT WITH BUILDING INFORMATION MAINTENANCE CONTACT : MAINTENANCE PHONE: ALARM COMPANY: ALARM PHONE: ALARM CODE : ALARM PASSWORD : FIRE DEPARTMENT: FIRE DEPT. PHONE : 5 nam St /& --r)26‘)5.4441‘..74 FITTER/LISTER NOTES 1. SEND 30' BULK 3/8" ATR FOR HANGERS 2. EXCLUDING WORK ON OVERTIME OR AFTER HOURS. 3. EXCLUDING RELOCATING OR MODIFYING THE EXISTING SPRINKLER SYSTEM TO ACCOMMODATE THE WORK OF OTHER TRADES. GENERAL NOTES 1. ALL STEEL PIPE TO BE AS FOLLOWS UNLESS NOTED OTHERWISE: STEEL PIPE ASTM A-795 OR BETTER PIPE SIZE SCHEDULE WALL THICKNESS INTERNAL DIAMETER END PREP TYPES ALLOWED SOF WATER/PPE "'R^' IN PALA,. 1 40 0.133 1.049 THREADED. CUT GROOVED, ROLL GROOVED, PLAIN END, POLISHED 2.05 0.044 1 1/4 40 0.140 1.380 THREADED, CUT 0800000, ROLL GROOVED, PLAN END, PCL1511E0 2.92 0.078 •' WALL THICKNESS PER NFPA dt 13 2. ALL GROOVED COUPLINGS TO BE RIGID TYPE UNLESS NOTED ( 11) WHICH ARE FLEXIBLE. SCOPE OF WORK SMITH FIRE SYSTEMS (SFS) WILL MODIFY THE EXISTING SPRINKLER SYSTEM TO ACCOMMODATE EXISTING ELECTRICAL ROOM. CLARIFICATIONS: 1. ALL AREAS PROTECTED BY A WET PIPE SYSTEM MUST BE MAINTAINED AT 40°F IN ORDER TO PREVENT FREEZING. EXCLUSIONS: 1. ANY WORK OUTSIDE THIS TENANT SPACE 2. PAINTING OR LABELING OF PIPE. 3. REPLACEMENT OF PAINTED, DAMAGED, OR CORRODED SPRINKLERS. 4. ELECTRICAL OR ALARM WORK OF ANY KIND. 5. BACKFLOW INSTALLATION, MODIFICATION, OR CERTIFICATION ((F REQUIRED) 6. EXCLUDING REPAIRS OR MODIFICATIONS TO THE EXISTING SYSTEM BEYOND THE SCOPE DESCRIBED ABOVE. DESIGN CRITERIA: PER NFPA 13 2007 AND THE CITY/COUNTY EXISTING CRITERIA RACK STORAGE NEW DESIGN CRITERIA: ORDINARY HAZARD TENANT IMPROVEMENT: THIS PROJECT ISA TENANT IMPROVEMENT. THIS FACILITY HAS ALREADY BEEN PROTECTED BY A FIRE SPRINKLER SYSTEM. SMITH FIRE SYSTEMS IS ADDING AND/OR RELOCATING SPRINKLER HEADS TO ACCOMMODATE THE NEW TENANT WALL, CEILING, LIGHTING, AND HVAC LAYOUT. ALL WORK WILL BE DONE WITHOUT AFFECTING THE CAPABILITY OF THE EXISTING SYSTEM. WATER SUPPLY INFORMATION STATIC 120 PSI RESIDUAL 84 PSI FLOWING 292 GPM LOCATION OF TEST BASE OF RISER DATA SUPPLIED BY RISER PLACARD ELEV. OF FLOW TEST: 16' ABOVE FLOOR LEVEL HYDRAULIC CALCULATION DATA ACTUAL DENSITY: .20 GPM / 184 SQUARE FEET DEMAND AT BASE OF RISER 56.3 GPM AT 40.5 PSI ( 0 GPM INSIDE HOSE ALLOWANCE) EDN RISER REA 1 F WORK S BOEING ACCESS ROAD SITE PLAN ?AI DEC -42009 d-Tukwil Firp, UNIFIED GROCERS PO BOX 3763 SEATTLE, WA 98124 PROJECT MANAGER : MARK HOEKS PHONE : 206.767.8709 FAX : 206.764.7739 CELL : 206.571.6064 C€IIPICATE OF 6BMFEJS46Y§TMMP NTS VJ Z_ cc 0 W 0 0 cc o 0 z o_ U ISMITH FIRE SYSTEMS, INC. 1106 54thEAVE EAST TACOMA, WA 98424 CONTR. REG. NO. SMITHFS1360T Bus: (253) 926-1880 FAX: (253) 928-2350 UNIFIED GROCERS 10430 E MARGINAL WAY TUKWILA, WA 98168 DESIGNER MATT G PROJECT MGR DATE SHEET JOB NO. 1,3D,09 1 HE TI91 O L UJVAAS 1OF 1