Loading...
HomeMy WebLinkAboutPP - 15215 52ND AVE S - PARK RIDGE BUILDING - PERMITS AND PLANS15215 52ND AVE S ASSOCIATED PERMITS D05-162 M02-059 14-F-078 14-F-061 13-F-217 44101,444 .PZIEN SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 1 15 72O CJs' l Site Address: 1Q216 62."12 /`>. S. Suite Number: Floor: Tenant Name: An+ez n 'L) Ii1b1\4e 8 New Tenant? ❑ - Yes No Property Owner's Name:ZCr)c ....Y1o&ior*6 LL L Mailing Address: 1'215- 52'\P Ave 5. itioo -r-a(„I,1e, CONTACT PERSON -if theretylcflux are questions about the submittal. n Name: City VA qt1St State Zip Day Telephone: 2% 32$ .328r ar Company Name: 1/VAS'h f\ r�ko/1`eet'(11 X\ L. .r Mailing Address: 20U)�(.() &CO We/ S' (e WA --5"I City State Zip E-mail Address: t (IN Fax Number: Total number of new/relocated devices or sprinkler heads: . Valuation of Project (contractor's bid price): $ 761 Scope of Work (please provide detailed information): 5 OUt .rt l 4ftf P(1t r kIctig Aar ( Cal tulaC "kZ(1SINAkVeC PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZE Signature: mei 2,? (7L_ Print Name: Ka.ta,tr Plan Permit App.doc Date:( q020/3 Day Telephone: 206- 328-- 3268/ 1/2/13 TFD FP Form 8 4410044 SITE LOCATION Site Address: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** IS2 t5 52, 4 Ave_ Tenant Name: t✓ 7 .J1 i C & RAG King Co. Assessor's Tax No.:) 157 212X2Q� ( % Suite Number: Floor: New Tenant? ❑ - Yes .- No Property Owner's Name: x k4 TZ A).l A IT:I.IVESTAWAIT-S LL—� I - q Mailing Address: ) 52 % 5 52/ 46 ASE Sc IrlVi.JI L—A wA 98/SS City State Zip CONTACT PERSON -if there are questions about the submittal. Name: &4P44. N1 [� I -t P& Q .� Day Telephone: 253 2;S9 -Z000 312 Company Name:1� 1 Qg/''j I Lj //��� Mailing Address: �/%2(�, ,13 r S7 1I4l X 1 •4L43LL WA 9gebe 1 City Sta e Zipp E-mail Address:�� �1 �O �l2$V L�10Et' JL c37M\ Fax Number: ZS ' $t‘i Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): E L.GCJT E (G, K T (� t v (CFz PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN R OR AUTHORI D AGENT: Signature: _ Date: 1/41-9-41./ Print Name: 11-61/44a/4 LCA MA.P4 Plan Permit App.doc Day Telephone: Z..53'- Si -G 1/2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 1 �2 rt /-t V G c 1 7CC I'(`e Suite Number: Floor: 14 7 - Tenant Tenant Name: .7 Y�� "` New Tenant? - Yes ❑ - No Property Owner's Name: Mailing Address: PO Y- R'`�"� : VS Z ($ STLAek �- S CONTACT PERSON -if there are questions about the submittal. Name: Sl •'� �' hr`-Ai'� c/tiff T) City State Zip Day Telephone( ) c7 Company Name: � r y E :C_ Mailing Address: 14C5.2.--6 ? $ 1 Nub SU : {'- iO I .4u f /ex Lti A- 41%00 \, 1 City State Zip _ E-mail Address: C S ( om' .-i D7 c Pc.t-f :C -Con-. Fax Number: 12-5.3) gsq ' z 3 b3 Total number of new/relocated devices or sprinkler heads: 7-0•6 Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): IY\ 2:J � C p pe0�C1 PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: ER HORIZED AGENT: Print Name: Date: 3/z4/`/ Day Telephone:S-f) " �s� `(— Z CO () Plan Permit App.doc 1/2/I3 TFD FP Form 8 i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:_ il Sprinklers: Type of Inspection: Address: i S a) 5 Suite #: 5-0- ,s.cd Pk, S Contact Person: Special Instructions: d+ bov �- eive( Az. Phone No.: Approved per applicable codes. rrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: A ADob Sino kms- d+ bov �- eive( Az. Perm r4 ()-Q J Covt)-�;` �p ;.v PklueL 1A4,a-K,' i .x f Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: J (\ sem_ Date: ,35//( Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 City of Tukwila Fire. Department DEC 2 2005 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name v e xe C o,,,� tA 'e" --/e7 t-, Address 1 5"-? j -- 5'7 Permit No. L/S /6 a. A441 CD< -nit, tv; Retain currrit inspection schedule Needs shift inspection Suite # ►Z*ppr iedwithout correction notice Approved with correction notice issued Sprinklers: Fire Alarm: -77-17- Hood , � ,7, Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Occupancy Type: CIO -Kuthorizegnature Final Approval Frm Rev. 5/2/03 �j I2/7 // Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 FIL City of Tukwila Fire Department Project Name TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM JUN 1 ;t 2002 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. %40;L 03 7 Address "s } -r� A v -S Suite # etain current inspection schedule Needs shift inspection Approved without correction notice S h,-ta(ow r c1o+ f P t,`';'` Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature Date FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 "IRBY FIRE &SECURITY A Division of Kirby Electric Inc. 4826 "B" St. NW Ste. 101 Telephone (253) 859-2000 Auburn, WA 98001 Fax (253) 859-2363 Date: April 14, 2014 Project: Park Ridge Building (Dynamic Language Tenant Improvement) 15215 52nd Ave South Tukwila, WA 98188 Scope: Relocate eight (8) existing devices to accommodate the Tenant Improvement on the second floor. This work will only affect NAC Circuits PS1 /3 & PS1 /4 on the Second Floor. Battery calculations have been modified to reflect he changes on the attached print. Shawn Lehman, ET Business Development / Estimator NICET III #124064 Cell: 253-740-0572 E-mail: shawn@kirbyelectric.com Kirby Electric, Inc. 1 KIRBY FIRE &SECURITY A Division of Kirby Electric Inc. 4826 "B" St. NW Ste. 101 Telephone (253) 859-2000 Auburn, WA 98001 Fax (253) 859-2363 Date: March 21, 2014 Project: Park Ridge Building (Dynamic Language) 15215 52nd Ave South Tukwila, WA 98188 Scope: Replace existing Conventional Fire Alarm System with new Addressable system. Work will consist of replacing all initiating devices, one for one, with addressable type units. Also included is a full building notification upgrade, following current TMC guidelines requiring notification in all rooms greater than 130 sq. ft. Main Fire Panel will be a Silent Knight 5820XL Addressable Panel, located in the first floor main lobby. Also installed will be one Silent Knight 5496 Notification Expansion Power Supply on the second floor. Point identification reporting will be accomplished with the existing AES RF Radio provided and monitored by Washington Alarm. Shawn Lehman, ET Business Development / Estimator NICET III #124064 Cell: 253-740-0572 E-mail: shawn@kirbyelectric.com Kirby Electric, Inc. YNA IC NG G L FIRE &SECURITY www. Kir 3yelectric.com CE Without Comments o As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformance with current City :esndards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this .acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 9/ —/ 7- i `I By: Al^n J�' I NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT - Please call 206-575-4407 and give this Fire Permit No. - F -o7$ and exact address for shut- down or rho t approval. DESIGNER OF RECORD JOB CONTACTS KIRBY ELECTRIC, INC. GENERAL PROJECT INFORMATION PAUL HOSKINS PAULH©KIRBYELECTRIC.COM DRAWING/DESIGN INFORMATION LEO KOT LEO@KIRBYELECTRIC_COM TECHNICIAN SCHEDULING PAUL HOSKINS PAULH©KIRBYELECTRIC.COM FA3 CE Without Comments o As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformance with current City :esndards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this .acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 9/ —/ 7- i `I By: Al^n J�' I NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT - Please call 206-575-4407 and give this Fire Permit No. - F -o7$ and exact address for shut- down or rho t approval. DESIGNER OF RECORD SHEET INDEX KIRBY ELECTRIC, INC. PAGE: DESCRIPTION PHONE: 253-859-2000 FA COVER SHEET FA1 FIRE ALARM DETAIL FA2 FIRST FLOOR FIRE ALARM PLAN FA3 SECOND FLOOR FIRE ALARM PLAN CE Without Comments o As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformance with current City :esndards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this .acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 9/ —/ 7- i `I By: Al^n J�' I NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT - Please call 206-575-4407 and give this Fire Permit No. - F -o7$ and exact address for shut- down or rho t approval. DESIGNER OF RECORD SHAWN LEHMAN KIRBY ELECTRIC, INC. 4826 B ST. NW SUITE 101 AUBURN, WA 98001 PHONE: 253-859-2000 FAX: 253-859-2363 NICET Fire Alarm Level III # 124064 FOR FIRE DEPARTMENT USE ONLY PAID APP 14 201 4 ILA FIRE Einar ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: 04-14-14 TENENAT IMPROVEMENT SCALE: N.T.S. DATE03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA JOB NO.: OF 0 GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 1 1. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm FIRE ALARM LEGEND SYMBOL DESCRIPTION �-.- FIRE ALARM CONTROL PANEL FACP 3 DEVICE FIRE ALARM ANNUNCIATOR FAA 14 GAUGE 2 CONDUCTOR (NAC) POWER SUPPLY P.S. 96" l WALL MNT. FIRE ALARM HORN/STROBE # INDICATES CANDELA RATING i 0; 4 CEILING MNT. FIRE ALARM HORN/STROBE # INDICATES CANDELA RATING C WALL MNT. FIRE ALARM STROBE ONLY INDICATES CANDELA RATING Co, I CEILING MNT. FIRE ALARM STROBE ONLY # INDICATES CANDELA RATING M MINI -HORN F FIRE ALARM MANUAL PULL STATION OSMOKE DETECTOR OH HEAT DETECTOR (Jl HEAT DETECTOR (ABOVE CEILING) E3DUCT SMOKE DETECTOR 2.52 BEAM SMOKE DETECTOR BS 60" 0.026 BEAM REFLECTOR BR Ion DF INPUT MODULE FOR DRY FLOW SWITCH M INPUT MODULE FOR WATER FLOW SWITCH HL INPUT MODULE FOR HIGH/LOW AIR T INPUT MODULE FOR TAMPER SWITCH PIV POST INDICATOR VALVE 0.339 A INPUT MODULE FOR ANSUL (BY OTHERS) DD INPUT MODULE For[ DUCT DETECTOR IM INPUT MODULE 0.000 DUAL INPUT MODULE IM2 0.000 10 INPUT MONITOR MODULE mg Acclimate R RELAY 4.7kf2 END OF LINE RESISTOR (E) EXISTING (R) RELOCATE SK NOTE: NOT ALL SYMBOLS ARE USED IN THESE DRAWINGS GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 1 1. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm WIRING LEGEND DEVICE HEIGHT SCHEDULE �-.- SYMBOL DESCRIPTION 3 DEVICE Prepared By:ISAL I Derating Factor.' 1.2 I HEIGHT 14 GAUGE 2 CONDUCTOR (NAC) B OUTDOOR HORN/STROBE 96" C HORN/STROBE (S -BUS) 80" 12 GAUGE 2 CONDUCTOR PULL STATION # 48" FIRE ALARM CONTROL PANEL 60" Ckt.# POWER SUPPLY Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 60" 5820XL CTRL Panel BELL 0.215 96" 2.52 ANNUNCIATOR Photo, Photo -T 60" 0.026 0.026 SK GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 1 1. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm WIRING LEGEND T> 1 1 Project NamePark Ridge Bldg Dynamic Lang.I Standby Hours:' 24 I �-.- SYMBOL DESCRIPTION 3 System Sensor P2/PC2 Hom/Strobe (30cd) Prepared By:ISAL I Derating Factor.' 1.2 I A 14 GAUGE 2 CONDUCTOR (NAC) B 16 GAUGE 2 CONDUCTOR (SLC) C 16 GAUGE 4 CONDUCTOR (S -BUS) D 12 GAUGE 2 CONDUCTOR (NAC) # CIRCUIT NUMBER I Volts: 24 VDC Max Panel Current 6.0 Amps #14 Solid 2.52 GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 1 1. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Project Name: Park Ridge Bldg - Dynamic Lang. Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt. Number: PGM -I/O #1 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit v. Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 T> 1 1 Project NamePark Ridge Bldg Dynamic Lang.I Standby Hours:' 24 I �-.- 0.000 Project ID:L ( Alarm Mins:1 5 I 3 System Sensor P2/PC2 Hom/Strobe (30cd) Prepared By:ISAL I Derating Factor.' 1.2 I 5 XL Cal on Date:13/19/2014 I Voltage Drop Waming 2 o12:3 Threshold%. 10 1 IVers 0.094 0.000 0.188 Panel ID: 15820XL I Model: 5820XL Add. Fire Alarm Control Panel Max NAC Current 3.0 Amps Location: (Main Lobby I Volts: 24 VDC Max Panel Current 6.0 Amps #14 Solid 2.52 260 Ckt.# Circuit Name qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5820XL 5820XL CTRL Panel 1 0.215 0.385 2.52 SK Photo, Photo -T 97 0.026 0.026 SK Ion 0.888 0.000 0.000 SK Heat, Heat -HT 29 0.008 0.008 SK Heat ROR 0.339 0.000 0.000 SK Beam, Beam -T 20.18 0.000 0.000 SK Duct 0.000 0.000 SK Acclimate 0.000 0.000 SK Control 0.000 0.000 SK Control -6 0.000 0.000 SK Relaymon 1.48 0.000 0.000 SK Monitor, Minimon 0.000 0.000 SK Monitor -2 0.000 0.000 SK Monitor -10 0.000 0.000 SK Pull -SA, Pull -DA 12 0.005 0.005 SK Relay 0.000 0.000 SK Relay -6 0.000 0.000 SK Zone 0.000 0.000 SK Zone -6 0.000 0.000 SK Isolator Module 0.000 0.000 SSB224BI Isolator Base 0.000 0.000 B200SR Sounder Base 0.000 0.000 SSB224RB Relay Base 0.000 0.000 SSRTS151 Magnetic Remote Test 0.000 0.000 SSRTS151KEY Key Activated Test 0.000 0.000 SSRA100Z Remote LED 0.000 0.000 5815XL SLC Loop Expander 1 0.055 0.055 5860 LCD Remote Annunc 0.000 0.000 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 1 0.010 0.010 5895XL Power Expander 0.000 0.000 58654 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 PGM -I/O #1 Notification Appl Circuit 0.000 0.800 #14 Solid 2.52 260 1.31 19.35 5.14% PGM -I/0 #2 Notification Appl Circuit 0.000 0.559 #14 Solid 2.52 180 0.91 19.89 2.49% PGM -I/O #3 Notification Appl Circuit 0.000 0.960 #14 Solid 2.52 250 1.26 19.19 5.93% PGM -1/0 #4 Notification Appl Circuit 0.000 0.562 #14 Solid 2.52 180 0.91 19.89 2.50% PGM -I/0 #5 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% PGM -I/0 #6 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% Total Standby Current (Amps) 0.319 3.370 Total Alarm Current Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/ 60 (5 Mins) Total Standby AH Required 7.644 0.281 Total Alarm AH Required Total Combined AH Required 7.93 Command Shortcuts Multiply By The Derating Factor 1.20 .. - Minimum Battery AmpHours Required 9.51 Configure Circuits Print Page Project Name: Park Ridge Bldg - Dynamic Lang. Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt. Number: PGM -I/O #1 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit v. Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.264 3 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.348 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 3 Unused 0.000 0.000 0.000 0.000 #14 Solid 2.52 260 1.31 0.000 0.000 Totals 0.000 0.800 Ckt. Number: PGM -I/0 #2 Panel ID: 5820XL Ckt. Name: Notification Appl CircuitI/O Use:: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.094 1 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.176 1 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.091 3 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.198 #14 Solid 2.52 260 1.31 0.000 0.000 Totals 0.000 0.559 Ckt. Number PGM -I/0 #3 Panel ID: 5820XL Ckt. Name: Notification Appl CircuitI/O Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.464 1 System Sensor P2/PC2 Hom/Strobe (75cd) 0.000 0.176 0.000 0.176 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 2 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.132 #14 Solid 2.52 260 1.31 0.000 0.000 Totals 0.000 0.960 Ckt. Number: PGM -I/0 #4 Panel ID: 5820XL Ckt. Name: Notification Appl CircuitI/O Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standb Alarm Standby Alarm 2 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.232 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 Location: (2nd Fir Electrical Closet I Volts: 24 VDC Max Panel Current 6.0 Amps Unused 0.000 0.000 0.000 0.000 0.160 Unused 0.000 0.000 0.000 0.000 #14 Solid 2.52 260 1.31 0.000 0.000 Totals 0.000 0.562 U LL SLC 1 15 .30 .30 15 30 .30 30 15 30 .75 .15 15 15 15 4.7k0 © 4 4.7kD 30 V730 r-,75 30 15 15 .30 30 .30 U) 0_ RJ31 X TELCO 120VAC 4.7kf1 ©© 4 30 30 15 15 15 15 .30 15 FIRE ALARM RISER SCALE: N.T.S. , � x� �-" , . - lobal Project Values: SILEI'C Project Name:IPark Ridge Bldg. 1 Standby Hours:/ 24 I KNIGHT Project ID:1 1 Alarm Mins:1 5 I 0.000 Prepared By:ISAL 1 Derating Factor:I 1.2 I 96 Power Expander Calculations'; Date:14/1412014 Voltage Drop Warning , Veon"02 24 09 rsi�w Threshold %-I 10 1 0.000 Panel ID: IPS1 1 Model: 5496 Power Expander Max NAC Current 3.0 Amps Location: (2nd Fir Electrical Closet I Volts: 24 VDC Max Panel Current 6.0 Amps System Sensor P2/PC2 Hom/Strobe (15cd) Part.# Description Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ % Drop Standby_ Alarm & Type 1000 Ft. One -Way Ohms EOL 5496 5496 Pwr Module I 1 0.040 0.160 System Sensor S/SC Strobe (15cd) NAC #1 Notification Appl Circuit 0.000 1.048 #14 Solid 2.52 260 1.31 19.03 6.73% NAC #2 Notification Appl Circuit 0.000 0.860 #14 Solid 2.52 195 0.98 19.55 4.14% NAC #3 Notification Appl Circuit 0.000 0.888 #14 Solid 2.52 205 1.03 19.48 4.50% NAC #4 Notification Appl Circuit 0.000 0.339 #14 Solid 2.52 130 0.66 20.18 1.09% Total Standby Current (Amps) 0.040 3.295 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 0.960 , 0.275 Total Alarm AH Required Total Combined AH Required 1.23 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum BatteryAmpHours Required 1.48 Configure Circuits Print Page 4.7kfl © 0 cL CD A B C D E NOTES: 1 SMOKE DETECTOR 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 PIV 6 DUCT DETECTOR A B C D E FIRE ALARM SYSTEM MATRIX SCALE N.T.S. Confgu roje n ormaon Project Name: Park Ridge Bldg. Prepared By: SAL Project ID: 0 Date: 4/14/2014 Ckt. Number: NAC #1 Panel ID: PS1 Ckt. Name: Notification Appi Circuit Use: Notification Appl Circuit mr F Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.464 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 0 System Sensor P2/PC2 Hom/Strobe (15cd) 0.000 0.091 0.000 0.000 6 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.396 0.000 0.000 Totals 0.000 1.048 Ckt. Number: NAC #2 Panel ID: PS1 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit 'I Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 3 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.348 0 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.000 2 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.182 - 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 0.000 0.000 Totals 0.000 0.860 Ckt. Number: NAC #3 Panel ID: PS1 Ckt. Name: Notification Appl Circuit - Use: Notification Appl Circuit v Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.464 1 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.094 0 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.000 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 0.000 0.000 Totals 0.000 0.888 Ckt. Number: NAC #4 Panel ID: PS1 _ Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Niir Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor P2/PC2 Ham/Strobe (30cd) 0.000 0.116 0.000 0.116 0 System Sensor S/SC Strobe (30cd) 0.000 - 0.094 0.000 0.000 - 1 System Sensor P2/PC2 Hom/Strobe (15cd) 0.000 0.091 0.000 0.091 2 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.132 0.000 0.000 Totals 0.000 0.339 MAli ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: 04-14-14 TENENAT IMPROVEMENT SCALE: N.T.S. DATE03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA1 JOB NO.: OF r 1 1 OFFICPL (15 6-1- B A L -0- £-B B IL 1 Ga J L r 15 A \;J OFFICE O ''CT. \ EY B 11-B 6P -B 0 o A 30 1�----3--- IIA A (P -B - --TO FA B / 30 E B 1 1-B 615 © E.O.L. FILE 0 0 15 O 1' �-B 1 30 TO FA/3 WP75 0 i r, -I n c) cps M TO FA/1 A EN f 'I` A A 30 0- -1-- -- 9'-B 00 1 B I WORK B -E AREA I) T B 15 E.O.L1 i ICE / rr �-A 30 J CE B IB IFFICE 1 SERV A 30 L B L 30 A 30 1 B ._. A 1 D 0- 5 30 A H 15 9-B OFFIC 15 OFFI 3 B L n A -E / WORKAREAL- ---- FIRST FLOOR - FIRE ALARM PLAN SCALE. 1/4'==1,-0" 4-B 3 B J ---QF1 a B 117227 ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: 04-14-14 TENENAT IMPROVEMENT SCALE: 1 /4" = 1'-0" DATE03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA2 JOB NO.: OF OFF B iIC IJ� --------� `I 2-I" fa 1 � 1 B ._. A 1 D 0- 5 30 A H 15 9-B OFFIC 15 OFFI 3 B L n A -E / WORKAREAL- ---- FIRST FLOOR - FIRE ALARM PLAN SCALE. 1/4'==1,-0" 4-B 3 B J ---QF1 a B 117227 ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: 04-14-14 TENENAT IMPROVEMENT SCALE: 1 /4" = 1'-0" DATE03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA2 JOB NO.: OF EXISTING BREAK d1 -B OFFICE OFFICE B r r B 4 SHARED OFFICE 2 ri t B I B 4 —r B 30 OPEN OFFICE A B 1 B-611 STORAGE SUITE 21 ENTRY/WAITING' A 1 L N_ A OPEN OFFICE — _ _'; — J B L B 9 -B n B CONF. B A-1 B 11- B — --- B I SUITE 24 I ENTRY/WAITING B BREAK/ KITCHENETTE B J B SUITE 23 Bk -A 1 OFFICE WOMEN'S R.R. A TO PS1 /3----J SHARED OFFICE OFFICE A --E HALL ( STORAGE TO PS1 t1 STORAGE r 1 1 30 I o (H�--- WO L. J A 1 30 B-'' 30 1 B 1 MEN � A 15 E.0.L. J B 4 TO P S1 /2---1 CP- A `1- B 130 VACANT SUITE 1 STORAGE OFFICE OFFICE 30 —J --EIA ---� 4-B 15 B -`b `P -A 1 30 N._ VACANT SUITE -t B 15 VACANT SUITE 1 (HL `P- B N_ —N 14(? STG. L 30 B 1 6560._ I 9�B J OFFICE OFFICE OFFICE STORAGE E.O.L. OFFICE OFFICE OFFICE OFFICE SECOND FLOOR — FIRE ALARM PLAN SCALE 1/4"=1'-0" 7(227 ELECTRICInc. COMMERCIAL• INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: 04-14-14 TENENAT IMPROVEMENT SCALE: 1 /4" = '-0" DATEb3-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA3 JOB NO.: OF SCOPE OF WORK: Swap out STU transmitter with a digital cellular transmitter. NOTE ON 463 CELL: U.L. approved as primary (standalone) fire communicator ANSI/UL864. Works on digital cellular networks over a variety of carriers. Fully supervised to ensure cellular communication path is intact and functional. Direct reporting to Central Stations DMP receiver. Full transmission of data. Local FACP will send the exact same zones that were on the STU(common alarm, common trouble) to the new DMP cell transmitter Zone 9: General Trouble Zone 10: General Alarm 120 VAC (DEDICATED CKT.) DMP XR100-FC W/ 463C CELL t 9 10 0p BATTERY I BATTERY VICINITY MAP FIRE ALARM RISER DIAGRAM SCHEMATIC: NO SCALE PYROTRON ICS FIRE ALARM CONTROL PANEL Pyrotronics panel monitors the initiating devices. PAID SEP 18 2013 TUKWILA FIRE cc iffy ‘%, WASHINGTONALARM INVESTMENTS ANTEZANA WASHINGTON ALARM INC. 2030 Almon Way South Seattle, WA. 98134 Job # 9772 Drawn by: Mark Mcllwain Ph: 206-328-3288 Fax: 206-322-7214 REVISIONS DATE DESCRIPTION 9/17/2013 PERMIT SET FIRE ALARM FA- 1 CCN.PTED ❑ Without Comments As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire ention Bureau ;e' conformance with current City .-•;derds. Acceptance is subject to errors and Which do not authorize violations of adopted ,dards and ordinances, The responsibility for the _.._ieauacy of design: !eets totally with the designer. ti: ; ionS, defer ix.. or revisions to these drawings after this mate void this acceptance and require a resubimtt o 7'evised drawings for subsequent approval. Final acce_Ttznce is suoj Ct to field test and inspection by T ne Tukwila Fire Fre J r inion Bureau. "I 3 By: _5—i i LN+s,A4.. $"o (Let 45ovc. qct essfoc.- d .4%cg.4 L;r4..4- Lrcc jni 119.5 liand1Le agi.%17 - TUKWILA FIRE DEPARTMEi Please call 205-575-4407 ana give this Fire Permit No. and exact address for shut- down or restoration approval. NOTICE 4 completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector priorto commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure .of test will result in a Re -inspection Fee and termination of the testing ❑ Without Comments 12( As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and i omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void thIs acceptance and will require a resubmittal of revised drawings for subsequent approval, Final acceptance Is subject to"field test and inspection by The Tukwila Fire Prevention Bureau.41^"' Date: Lt ( By: 'IE Retsw-k L.t . O., S ret,i4,1 to,. eiSo.t Ce dloi-.✓to s o - O --- arp w.e4v.3. )(' 176, ,•4- T .17 • rr�,i�•;� w� C� � 1 S Vet,+t'Cx, y- NLrevpc,. hgti�� tla�-„ c d4 t c FAL b►zvi'c� • ho4 o ) .lot/ €k0.17i+,sh1( �,►s a4yl•kia� %G7So,e NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector pilor to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and givee �t it ePermit.No. Ot and exact address for shut- down hutdown or restoration approval. FIRE &SECURITY W w w . Kir 3yelectric.com DESIGNER OF RECORD JOB CONTACTS KIRBY ELECTRIC, INC. GENERAL PROJECT INFORMATION PAUL HOSKINS PAULH©KIRBYELECTRIC.COM DRAWING/DESIGN INFORMATION LEO KOT LEO©KIRBYELECTRIC.COM TECHNICIAN SCHEDULING PAUL HOSKINS PAULH©KIRBYELECTRIC.COM FIRST FLOOR FIRE ALARM PLAN DESIGNER OF RECORD SHEET INDEX KIRBY ELECTRIC, INC. PAGE: DESCRIPTION PHONE: 253-859-2000 FAX: 253-859-2363 FA COVER SHEET FA1 FIRE ALARM DETAIL FA2 FIRST FLOOR FIRE ALARM PLAN FA3 SECOND FLOOR FIRE ALARM PLAN DESIGNER OF RECORD SHAWN LEHMAN KIRBY ELECTRIC, INC. 4826 B ST. NW SUITE 101 AUBURN, WA 98001 PHONE: 253-859-2000 FAX: 253-859-2363 NICET Fire Alarm Level III # 124064 FOR FIRE DEPARTMENT USE ONLY PAID MAR 28 201 TUKWILA F Cc 09r - RE MAST ELECTRICInc. COMMERCIAL• INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Aubum, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: SCALE: N.T.S. DATE 03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET JOB NO.: OF GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTH FORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPEC IRICATIONS, THEY ARE INTENDED AS A CUfflLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm FIRE ALARM LEGEND SYMBOL DESCRIPTION DESCRIPTION 0.000 A FIRE ALARM CONTROL PANEL FACP B HEIGHT FIRE ALARM ANNUNCIATOR FAA 16 GAUGE 4 CONDUCTOR OUTDOOR HORN/STROBE POWER SUPPLY P.S. HORN/STROBE al WALL MNT. FIRE ALARM HORN/STROBE # INDICATES CANDELA RATING CO( - CEILING MNT. FIRE ALARM HORN/STROBE INDICATES CANDELA RATING ;O: WALL MNT. FIRE ALARM STROBE ONLY INDICATES CANDELA RATING 0 CEILING MNT. FIRE ALARM STROBE ONLY # INDICATES CANDELA RATING yn MINI -HORN F FIRE ALARM MANUAL PULL STATION OSMOKE DETECTOR OHEAT DETECTOR 0 HEAT DETECTOR (ABOVE CEILING) Mil DUCT SMOKE DETECTOR Heat ROR BEAM SMOKE DETECTOR BS 0.000 SK BEAM REFLECTOR BR 0.000 DF INPUT MODULE FOR DRY FLOW SWITCH NI INPUT MODULE FOR WATERFLOW SWITCH HL INPUT MODULE FOR HIGH/LOW AIR T INPUT MODULE FOR TAMPER SWITCH 0.405 POST INDICATOR VALVE PIV SK A INPUT MODULE FOR ANSUL (BY OTHERS) 3 INPUT MODULE FOR DUCT DETECTOR IM INPUT MODULE DUAL INPUT MODULE IM2 SK Relaymon 10 INPUT MONITOR MODULE mi[,i' 0.000 R RELAY 4_ END OF LINE RESISTOR (E) EXISTING (R) RELOCATE NOTE: NOT ALL SYMBOLS ARE USED IN THESE DRAWINGS 0.000 GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTH FORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPEC IRICATIONS, THEY ARE INTENDED AS A CUfflLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm WIRING LEGEND DEVICE HEIGHT SCHEDULE DESCRIPTION 0.000 A 14 GAUGE 2 CONDUCTOR DEVICE B HEIGHT (SLC) C 16 GAUGE 4 CONDUCTOR OUTDOOR HORN/STROBE 96" 12 GAUGE 2 CONDUCTOR HORN/STROBE # 80" 0.385 PULL STATION SK 48" FIRE ALARM CONTROL PANEL 60" Ion POWER SUPPLY 0.000 60" SK BELL 29 96" 0.008 ANNUNCIATOR Heat ROR 60" 0.000 0.000 SK GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTH FORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPEC IRICATIONS, THEY ARE INTENDED AS A CUfflLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm WIRING LEGEND Project Name:1Park Ridge Bldg - Dynamic Lang. I Standby Hours:1 24 1 SYMBOL DESCRIPTION 0.000 A 14 GAUGE 2 CONDUCTOR (NAC) B 16 GAUGE 2 CONDUCTOR (SLC) C 16 GAUGE 4 CONDUCTOR (S -BUS) D 12 GAUGE 2 CONDUCTOR (NAC) # CIRCUIT NUMBER 0.385 0.000 SK GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTH FORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPEC IRICATIONS, THEY ARE INTENDED AS A CUfflLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Project Name: Park Ridge Bldg - Dynamic Lang. Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt. Number, PGM -1/0 #1 Panel ID: 5820XL Ckt. Name: Notification App' Circuit I/O Use: Notification Appl Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm SZLEi4T€, Project Name:1Park Ridge Bldg - Dynamic Lang. I Standby Hours:1 24 1 ZG IT Project ID:1 1 Alarm Mins:1 5 1 0.000 Prepared By:'SAL ( Derating Factor.} 1.2 } 5820XL Calculations ; Date:13/19/2014 I Voltage Drop Waming 0.000 Threshold %:1 10 1 0.000 Panel ID: 15820XL I Model: 5820XL Add. Fire Alarm Control Panel Max NAC Current 3.0 Amps Location: 'Main Lobby 1 Volts: 24 VDC Max Panel Current 6.0 Amps System Sensor S/SC Strobe (30cd) Ckt.# Circuit Name Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts © %Drop Standb Alarm & Type 1000 Ft. One -Way Ohms EOL 5820XL 5820XL CTRL Panel 1 0.215 0.385 0.000 SK Photo, Photo -T 97 0.026 0.026 SK Ion 0.000 0.000 0.000 SK Heat, Heat -HT 29 0.008 0.008 SK Heat ROR 19.32 0.000 0.000 SK Beam, Beam -T 0.888 0.000 0.000 SK Duct 19.24 0.000 0.000 SK Acclimate 0.405 0.000 0.000 SK Control 20.08 0.000 0.000 SK Control -6 0.000 0.000 SK Relaymon 0.000 0.000 SK Monitor, Minimon 0.000 0.000 SK Monitor -2 0.000 0.000 SK Monitor -10 0.000 0.000 SK Pull -SA, Pull -DA 12 0.005 0.005 SK Relay 0.000 0.000 SK Relay -6 0.000 0.000 SK Zone 0.000 0.000 SK Zone -6 0.000 0.000 SK Isolator Module 0.000 0.000 SSB224B1 Isolator Base 0.000 0.000 B200SR Sounder Base 0.000 0.000 SSB224R6 Relay Base 0.000 0.000 SSRTS151 Magnetic Remote Test 0.000 0.000 SSRTS151KEY Key Activated Test 0.000 0.000 SSRA100Z Remote LED 0.000 0.000 5815XL SLC Loop Expander 1 0.055 0.055 5860 LCD Remote Annunc 0.000 0.000 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 1 0.010 0.010 5895XL Power Expander 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 PGM -1/0 #1 Notification Appl Circuit 0.000 0.800 #14 Solid 2.52 260 1.31 19.35 5.14% PGM -I/O #2 Notification Appl Circuit 0.000 0.559 #14 Solid 2.52 180 0.91 19.89 2.49% PGM -I/O #3 Notification Appl Circuit 0.000 0.960 #14 Solid 2.52 250 1.26 19.19 5.93% PGM -1/0 #4 Notification Appl Circuit 0.000 0.562 #14 Solid 2.52 180 0.91 19.89 2.50% PGM -I/O #5 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% PGM -I/O #6 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% Total Standby Current (Amps) 0.319 3.370 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm lime In Minutes / 60 (5 Mins) Total Standby AH Required 7.644 0.281 Total Alarm AH Required Total Combined AH Required 7.93 Command Shortcuts Multiply By The Derating Factor 1.20 9.51 Configure Circuits Print Page Minimum Battery AmpHours Required Project Name: Park Ridge Bldg - Dynamic Lang. Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt. Number, PGM -1/0 #1 Panel ID: 5820XL Ckt. Name: Notification App' Circuit I/O Use: Notification Appl Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.264 3 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.348 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 3 Unused 0.000 0.000 0.000 0.000 #14 Solid 2.52 290 1.46 0.000 0.000 Totals 0.000 0.800 Ckt. Number. PGM -I/0 #2 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.094 1 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.176 1 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.091 3 System Sensor S/SC Strobe (15cd) 0.000 0-066 0.000 0.198 #14 Solid 2.52 290 1.46 0.000 0.000 Totals 0.000 0.559 Ckt. Number. PGM -I/0 #3 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit v Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.464 1 System Sensor P2/PC2 Hom/Strobe (75cd) 0.000 0.176 0.000 0.176 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 2 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.132 #14 Solid 2.52 290 1.46 0.000 0.000 Totals 0.000 0.960 Ckt. Number: PGM -I/0 #4 Panel ID: 5820XL Ckt. Name: Notification A I Circuit I/O Use:' Notification ation Appl Circuit Nri Qty Device Current Draw Each Current Draw Total Standby Alarm. Standby Alarm 2 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.232 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 Location: 12nd Floor - Phone Closet 1 Volts: 24 VDC Max Panel Current: 6.0 Amps Unused 0.000 0-000 0.000 0.000 0.160 Unused 0.000 0.000 0.000 0.000 #14 Solid 2.52 290 1.46 0.000 0.000 Totals 0.000 0.562 15 .30 .30 15 30 .30 30 15 30 15 15 15 15 .30 15 V) 0 PS1 RJ31X TELCO 120VAC 30 4.7k0 4.7kri 30 30 15 .30 30 15 15 15 15 II II II II IRI I) (o;l FIRE ALARM RISER 30 15 SCALE N.T.S. 4.7kQQ A B C D E NOTES: 1 SMOKE DETECTOR 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 PIV 6 DUCT DETECTOR A B C D E FIRE ALARM SYSTEM MA TR1X SCALE N.T.S. [Project Name: Park Ridge Bldg. - Dynamic Lang Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt- Number. NAC #1 Panel ID: PS1 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Iv t Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm .S1 Project Name:'Park Ridge Bldg. -Dynamic Lang► Standby Hours:L 24 ( KNIGH t ProjectlD:1 I Alarm Mins: r 5 1 0.000 Prepared By:}SAL 1 Derating Factor:L 1.2 1 5496ower pander Calauiahons� � e Date:13/19/2014 I Voltage Drop Warning ,.n,2 24.0 Version 02 24 09 Threshold %: 1 10 1 0.000 Panel ID: IPS' 1 Model: 5496 Power Expander Max MAC Current: 3.0 Amps Location: 12nd Floor - Phone Closet 1 Volts: 24 VDC Max Panel Current: 6.0 Amps System Sensor S/SC Strobe (30cd) Part.# Description Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ a/Drop Standby_ Alarm & Type 1000 Ft. One -Way Ohms EOL 5496 5496 Pwr Module 1 1 0.040 0.160 Unused NAC #1 Notification Appl Circuit 0.000 1.048 #14 Solid 2.52 290 1.46 18.87 7.51% NAC #2 Notification Appl Circuit 0.000 0.860 #14 Solid 2.52 250 1.26 19.32 5.31% NAC #3 Notification Appl Circuit 0.000 0.888 #14 Solid 2.52 260 1.31 19.24 5.70% NAC #4 Notification Appl Circuit 0.000 0.405 #14 Solid 2.52 155 0.78 20.08 1.55% Total Standby Current (Amps) 0.040 3.361 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 0.960 0.280 Total Alarm AH Required Total Combined AH Required 1.24 Command Shortcuts Multiply By The Derating Factor 1.20 1.49 Configure Circuits Print Page Minimum Battery AmpHours Required 4.7kQQ A B C D E NOTES: 1 SMOKE DETECTOR 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 PIV 6 DUCT DETECTOR A B C D E FIRE ALARM SYSTEM MA TR1X SCALE N.T.S. [Project Name: Park Ridge Bldg. - Dynamic Lang Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt- Number. NAC #1 Panel ID: PS1 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Iv t Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 • 0.000 0.464 6 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0,396 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 5 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.048 Ckt. Number NAC #2 Panel ID: PS1 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 3 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.348 2 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.182 0 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.000 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 0.000 0.000 Totals 0.000 0.860 Ckt. Number. NAC #3 Panel ID: PS1 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.464 1 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.094 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.888 Ckt. Number: NAC #4 Panel ID: PS1 Use:, Notification Appl Circuit Ckt. Name: Notification Appl CircuitUse: Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.116 1 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 - 0.000 0.091 3 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.198 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.405 MEET ELECTRICInc. COMMERCIAL• INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Aubum, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: SCALE: N.T.S. DATE03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA1 JOB NO.: OF ?- —1 • f 5 B B 6.13, A +—B LHL4 1 A B 1 30 B B —+ ) 15 OFFICE •••••• +—B \— — —0•TO F/A/4 A +—B 15 ---..T0 FA/1 A fL A 1 30 65 E.O.L. OFFICE d_A 0 1 —f1N- A +—B WORK AREA B-4 30 B 0- +— A 30 1—A 30 1 _ 1 B TO FA/2-.-- 443:00 B 30 30 coa C 0 N r- E 1—B SE R a VJO R A AV \REA B 4 - B— J ch or J WORK AREA B B 1 emmoomm... 11 15 30 1 9—B I -r ) J 115 15 4—B 1 —f ck—B OFFICE FIRST FLOOR — FIRE ALARM PLAN SCALE 1/4'=1 =0" r UP 11111BY ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Aubum, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: SCALE: 1/4" = 1 '-0" "1E03-18-14 DRAWN BY: L.K. NECKED BY; SL SHEET FA2 JOB NO.: OF STAFF 1 OFFICE B B OFFICE B B B 30 A B 1 F 30 L B 4- 1 A r- 30 --1 E0.L. 1 1 A 30 n 4 jnizna. I L, r=nnt Agn.% B 9—A B _r OFR - 30 9' A A r B —+ STORAGE B B 30 WORK AREA B q3.00(11) —Et [--.-TO PS1 /4 B 1 1 •,••••••• 1 A --- B 30 A V\/OM B 1 15 LA 1:7 411 1— A k rt; 5 E.O.L. no% e 1' B TO PS1 B / 30 15 TO PS1 /3-- 1 Th 3 B-11 OFRCE 15 OFFICE B 30 15 A A OFFICE B OFFICE Et B +— B TO PSI 1 +— A (HL\ -r B --a STG. +— B 1 A B B B WORK A AREA — 0Frd,Lr: I 1—B 1 30 63 tonaat B —E 61 OR Ef— B 1 A —+ 30 y co; E. O. L. A A B -------.., Li r= r 2i i7 OFFICE B — 4E1 - B OFFICE — — OFF CP 15 1— A B ••••••••, J 30 A -4B if DN OFFICE SECOND FLOOR - FIRE ALARM PLAN SCALE Ve=1 2 0 mar ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Aubum, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 11 1 1 1 REVISIONS: SCALE: 1/4" = 1 '—tr DATEO3-18-14 DRAWN BY: L.K.s CHECKED BY:e SHEET FA3 JOB NO.: OF 15215 52ND AVE S ASSOCIATED PERMITS D05-162 M02-059 14-F-078 14-F-061 13-F-217 44101,444 .PZIEN SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 1 15 72O CJs' l Site Address: 1Q216 62."12 /`>. S. Suite Number: Floor: Tenant Name: An+ez n 'L) Ii1b1\4e 8 New Tenant? ❑ - Yes No Property Owner's Name:ZCr)c ....Y1o&ior*6 LL L Mailing Address: 1'215- 52'\P Ave 5. itioo -r-a(„I,1e, CONTACT PERSON -if theretylcflux are questions about the submittal. n Name: City VA qt1St State Zip Day Telephone: 2% 32$ .328r ar Company Name: 1/VAS'h f\ r�ko/1`eet'(11 X\ L. .r Mailing Address: 20U)�(.() &CO We/ S' (e WA --5"I City State Zip E-mail Address: t (IN Fax Number: Total number of new/relocated devices or sprinkler heads: . Valuation of Project (contractor's bid price): $ 761 Scope of Work (please provide detailed information): 5 OUt .rt l 4ftf P(1t r kIctig Aar ( Cal tulaC "kZ(1SINAkVeC PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZE Signature: mei 2,? (7L_ Print Name: Ka.ta,tr Plan Permit App.doc Date:( q020/3 Day Telephone: 206- 328-- 3268/ 1/2/13 TFD FP Form 8 4410044 SITE LOCATION Site Address: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** IS2 t5 52, 4 Ave_ Tenant Name: t✓ 7 .J1 i C & RAG King Co. Assessor's Tax No.:) 157 212X2Q� ( % Suite Number: Floor: New Tenant? ❑ - Yes .- No Property Owner's Name: x k4 TZ A).l A IT:I.IVESTAWAIT-S LL—� I - q Mailing Address: ) 52 % 5 52/ 46 ASE Sc IrlVi.JI L—A wA 98/SS City State Zip CONTACT PERSON -if there are questions about the submittal. Name: &4P44. N1 [� I -t P& Q .� Day Telephone: 253 2;S9 -Z000 312 Company Name:1� 1 Qg/''j I Lj //��� Mailing Address: �/%2(�, ,13 r S7 1I4l X 1 •4L43LL WA 9gebe 1 City Sta e Zipp E-mail Address:�� �1 �O �l2$V L�10Et' JL c37M\ Fax Number: ZS ' $t‘i Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): E L.GCJT E (G, K T (� t v (CFz PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN R OR AUTHORI D AGENT: Signature: _ Date: 1/41-9-41./ Print Name: 11-61/44a/4 LCA MA.P4 Plan Permit App.doc Day Telephone: Z..53'- Si -G 1/2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 1 �2 rt /-t V G c 1 7CC I'(`e Suite Number: Floor: 14 7 - Tenant Tenant Name: .7 Y�� "` New Tenant? - Yes ❑ - No Property Owner's Name: Mailing Address: PO Y- R'`�"� : VS Z ($ STLAek �- S CONTACT PERSON -if there are questions about the submittal. Name: Sl •'� �' hr`-Ai'� c/tiff T) City State Zip Day Telephone( ) c7 Company Name: � r y E :C_ Mailing Address: 14C5.2.--6 ? $ 1 Nub SU : {'- iO I .4u f /ex Lti A- 41%00 \, 1 City State Zip _ E-mail Address: C S ( om' .-i D7 c Pc.t-f :C -Con-. Fax Number: 12-5.3) gsq ' z 3 b3 Total number of new/relocated devices or sprinkler heads: 7-0•6 Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): IY\ 2:J � C p pe0�C1 PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: ER HORIZED AGENT: Print Name: Date: 3/z4/`/ Day Telephone:S-f) " �s� `(— Z CO () Plan Permit App.doc 1/2/I3 TFD FP Form 8 i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:_ il Sprinklers: Type of Inspection: Address: i S a) 5 Suite #: 5-0- ,s.cd Pk, S Contact Person: Special Instructions: d+ bov �- eive( Az. Phone No.: Approved per applicable codes. rrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: A ADob Sino kms- d+ bov �- eive( Az. Perm r4 ()-Q J Covt)-�;` �p ;.v PklueL 1A4,a-K,' i .x f Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: J (\ sem_ Date: ,35//( Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 City of Tukwila Fire. Department DEC 2 2005 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name v e xe C o,,,� tA 'e" --/e7 t-, Address 1 5"-? j -- 5'7 Permit No. L/S /6 a. A441 CD< -nit, tv; Retain currrit inspection schedule Needs shift inspection Suite # ►Z*ppr iedwithout correction notice Approved with correction notice issued Sprinklers: Fire Alarm: -77-17- Hood , � ,7, Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Occupancy Type: CIO -Kuthorizegnature Final Approval Frm Rev. 5/2/03 �j I2/7 // Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 FIL City of Tukwila Fire Department Project Name TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM JUN 1 ;t 2002 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. %40;L 03 7 Address "s } -r� A v -S Suite # etain current inspection schedule Needs shift inspection Approved without correction notice S h,-ta(ow r c1o+ f P t,`';'` Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature Date FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 "IRBY FIRE &SECURITY A Division of Kirby Electric Inc. 4826 "B" St. NW Ste. 101 Telephone (253) 859-2000 Auburn, WA 98001 Fax (253) 859-2363 Date: April 14, 2014 Project: Park Ridge Building (Dynamic Language Tenant Improvement) 15215 52nd Ave South Tukwila, WA 98188 Scope: Relocate eight (8) existing devices to accommodate the Tenant Improvement on the second floor. This work will only affect NAC Circuits PS1 /3 & PS1 /4 on the Second Floor. Battery calculations have been modified to reflect he changes on the attached print. Shawn Lehman, ET Business Development / Estimator NICET III #124064 Cell: 253-740-0572 E-mail: shawn@kirbyelectric.com Kirby Electric, Inc. 1 KIRBY FIRE &SECURITY A Division of Kirby Electric Inc. 4826 "B" St. NW Ste. 101 Telephone (253) 859-2000 Auburn, WA 98001 Fax (253) 859-2363 Date: March 21, 2014 Project: Park Ridge Building (Dynamic Language) 15215 52nd Ave South Tukwila, WA 98188 Scope: Replace existing Conventional Fire Alarm System with new Addressable system. Work will consist of replacing all initiating devices, one for one, with addressable type units. Also included is a full building notification upgrade, following current TMC guidelines requiring notification in all rooms greater than 130 sq. ft. Main Fire Panel will be a Silent Knight 5820XL Addressable Panel, located in the first floor main lobby. Also installed will be one Silent Knight 5496 Notification Expansion Power Supply on the second floor. Point identification reporting will be accomplished with the existing AES RF Radio provided and monitored by Washington Alarm. Shawn Lehman, ET Business Development / Estimator NICET III #124064 Cell: 253-740-0572 E-mail: shawn@kirbyelectric.com Kirby Electric, Inc. YNA IC NG G L FIRE &SECURITY www. Kir 3yelectric.com CE Without Comments o As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformance with current City :esndards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this .acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 9/ —/ 7- i `I By: Al^n J�' I NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT - Please call 206-575-4407 and give this Fire Permit No. - F -o7$ and exact address for shut- down or rho t approval. DESIGNER OF RECORD JOB CONTACTS KIRBY ELECTRIC, INC. GENERAL PROJECT INFORMATION PAUL HOSKINS PAULH©KIRBYELECTRIC.COM DRAWING/DESIGN INFORMATION LEO KOT LEO@KIRBYELECTRIC_COM TECHNICIAN SCHEDULING PAUL HOSKINS PAULH©KIRBYELECTRIC.COM FA3 CE Without Comments o As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformance with current City :esndards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this .acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 9/ —/ 7- i `I By: Al^n J�' I NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT - Please call 206-575-4407 and give this Fire Permit No. - F -o7$ and exact address for shut- down or rho t approval. DESIGNER OF RECORD SHEET INDEX KIRBY ELECTRIC, INC. PAGE: DESCRIPTION PHONE: 253-859-2000 FA COVER SHEET FA1 FIRE ALARM DETAIL FA2 FIRST FLOOR FIRE ALARM PLAN FA3 SECOND FLOOR FIRE ALARM PLAN CE Without Comments o As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire prevention Bureau for conformance with current City :esndards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this .acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 9/ —/ 7- i `I By: Al^n J�' I NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT - Please call 206-575-4407 and give this Fire Permit No. - F -o7$ and exact address for shut- down or rho t approval. DESIGNER OF RECORD SHAWN LEHMAN KIRBY ELECTRIC, INC. 4826 B ST. NW SUITE 101 AUBURN, WA 98001 PHONE: 253-859-2000 FAX: 253-859-2363 NICET Fire Alarm Level III # 124064 FOR FIRE DEPARTMENT USE ONLY PAID APP 14 201 4 ILA FIRE Einar ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: 04-14-14 TENENAT IMPROVEMENT SCALE: N.T.S. DATE03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA JOB NO.: OF 0 GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 1 1. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm FIRE ALARM LEGEND SYMBOL DESCRIPTION �-.- FIRE ALARM CONTROL PANEL FACP 3 DEVICE FIRE ALARM ANNUNCIATOR FAA 14 GAUGE 2 CONDUCTOR (NAC) POWER SUPPLY P.S. 96" l WALL MNT. FIRE ALARM HORN/STROBE # INDICATES CANDELA RATING i 0; 4 CEILING MNT. FIRE ALARM HORN/STROBE # INDICATES CANDELA RATING C WALL MNT. FIRE ALARM STROBE ONLY INDICATES CANDELA RATING Co, I CEILING MNT. FIRE ALARM STROBE ONLY # INDICATES CANDELA RATING M MINI -HORN F FIRE ALARM MANUAL PULL STATION OSMOKE DETECTOR OH HEAT DETECTOR (Jl HEAT DETECTOR (ABOVE CEILING) E3DUCT SMOKE DETECTOR 2.52 BEAM SMOKE DETECTOR BS 60" 0.026 BEAM REFLECTOR BR Ion DF INPUT MODULE FOR DRY FLOW SWITCH M INPUT MODULE FOR WATER FLOW SWITCH HL INPUT MODULE FOR HIGH/LOW AIR T INPUT MODULE FOR TAMPER SWITCH PIV POST INDICATOR VALVE 0.339 A INPUT MODULE FOR ANSUL (BY OTHERS) DD INPUT MODULE For[ DUCT DETECTOR IM INPUT MODULE 0.000 DUAL INPUT MODULE IM2 0.000 10 INPUT MONITOR MODULE mg Acclimate R RELAY 4.7kf2 END OF LINE RESISTOR (E) EXISTING (R) RELOCATE SK NOTE: NOT ALL SYMBOLS ARE USED IN THESE DRAWINGS GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 1 1. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm WIRING LEGEND DEVICE HEIGHT SCHEDULE �-.- SYMBOL DESCRIPTION 3 DEVICE Prepared By:ISAL I Derating Factor.' 1.2 I HEIGHT 14 GAUGE 2 CONDUCTOR (NAC) B OUTDOOR HORN/STROBE 96" C HORN/STROBE (S -BUS) 80" 12 GAUGE 2 CONDUCTOR PULL STATION # 48" FIRE ALARM CONTROL PANEL 60" Ckt.# POWER SUPPLY Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 60" 5820XL CTRL Panel BELL 0.215 96" 2.52 ANNUNCIATOR Photo, Photo -T 60" 0.026 0.026 SK GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 1 1. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm WIRING LEGEND T> 1 1 Project NamePark Ridge Bldg Dynamic Lang.I Standby Hours:' 24 I �-.- SYMBOL DESCRIPTION 3 System Sensor P2/PC2 Hom/Strobe (30cd) Prepared By:ISAL I Derating Factor.' 1.2 I A 14 GAUGE 2 CONDUCTOR (NAC) B 16 GAUGE 2 CONDUCTOR (SLC) C 16 GAUGE 4 CONDUCTOR (S -BUS) D 12 GAUGE 2 CONDUCTOR (NAC) # CIRCUIT NUMBER I Volts: 24 VDC Max Panel Current 6.0 Amps #14 Solid 2.52 GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 1 1. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTHFORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Project Name: Park Ridge Bldg - Dynamic Lang. Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt. Number: PGM -I/O #1 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit v. Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 T> 1 1 Project NamePark Ridge Bldg Dynamic Lang.I Standby Hours:' 24 I �-.- 0.000 Project ID:L ( Alarm Mins:1 5 I 3 System Sensor P2/PC2 Hom/Strobe (30cd) Prepared By:ISAL I Derating Factor.' 1.2 I 5 XL Cal on Date:13/19/2014 I Voltage Drop Waming 2 o12:3 Threshold%. 10 1 IVers 0.094 0.000 0.188 Panel ID: 15820XL I Model: 5820XL Add. Fire Alarm Control Panel Max NAC Current 3.0 Amps Location: (Main Lobby I Volts: 24 VDC Max Panel Current 6.0 Amps #14 Solid 2.52 260 Ckt.# Circuit Name qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5820XL 5820XL CTRL Panel 1 0.215 0.385 2.52 SK Photo, Photo -T 97 0.026 0.026 SK Ion 0.888 0.000 0.000 SK Heat, Heat -HT 29 0.008 0.008 SK Heat ROR 0.339 0.000 0.000 SK Beam, Beam -T 20.18 0.000 0.000 SK Duct 0.000 0.000 SK Acclimate 0.000 0.000 SK Control 0.000 0.000 SK Control -6 0.000 0.000 SK Relaymon 1.48 0.000 0.000 SK Monitor, Minimon 0.000 0.000 SK Monitor -2 0.000 0.000 SK Monitor -10 0.000 0.000 SK Pull -SA, Pull -DA 12 0.005 0.005 SK Relay 0.000 0.000 SK Relay -6 0.000 0.000 SK Zone 0.000 0.000 SK Zone -6 0.000 0.000 SK Isolator Module 0.000 0.000 SSB224BI Isolator Base 0.000 0.000 B200SR Sounder Base 0.000 0.000 SSB224RB Relay Base 0.000 0.000 SSRTS151 Magnetic Remote Test 0.000 0.000 SSRTS151KEY Key Activated Test 0.000 0.000 SSRA100Z Remote LED 0.000 0.000 5815XL SLC Loop Expander 1 0.055 0.055 5860 LCD Remote Annunc 0.000 0.000 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 1 0.010 0.010 5895XL Power Expander 0.000 0.000 58654 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 PGM -I/O #1 Notification Appl Circuit 0.000 0.800 #14 Solid 2.52 260 1.31 19.35 5.14% PGM -I/0 #2 Notification Appl Circuit 0.000 0.559 #14 Solid 2.52 180 0.91 19.89 2.49% PGM -I/O #3 Notification Appl Circuit 0.000 0.960 #14 Solid 2.52 250 1.26 19.19 5.93% PGM -1/0 #4 Notification Appl Circuit 0.000 0.562 #14 Solid 2.52 180 0.91 19.89 2.50% PGM -I/0 #5 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% PGM -I/0 #6 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% Total Standby Current (Amps) 0.319 3.370 Total Alarm Current Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/ 60 (5 Mins) Total Standby AH Required 7.644 0.281 Total Alarm AH Required Total Combined AH Required 7.93 Command Shortcuts Multiply By The Derating Factor 1.20 .. - Minimum Battery AmpHours Required 9.51 Configure Circuits Print Page Project Name: Park Ridge Bldg - Dynamic Lang. Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt. Number: PGM -I/O #1 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit v. Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.264 3 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.348 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 3 Unused 0.000 0.000 0.000 0.000 #14 Solid 2.52 260 1.31 0.000 0.000 Totals 0.000 0.800 Ckt. Number: PGM -I/0 #2 Panel ID: 5820XL Ckt. Name: Notification Appl CircuitI/O Use:: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.094 1 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.176 1 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.091 3 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.198 #14 Solid 2.52 260 1.31 0.000 0.000 Totals 0.000 0.559 Ckt. Number PGM -I/0 #3 Panel ID: 5820XL Ckt. Name: Notification Appl CircuitI/O Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.464 1 System Sensor P2/PC2 Hom/Strobe (75cd) 0.000 0.176 0.000 0.176 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 2 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.132 #14 Solid 2.52 260 1.31 0.000 0.000 Totals 0.000 0.960 Ckt. Number: PGM -I/0 #4 Panel ID: 5820XL Ckt. Name: Notification Appl CircuitI/O Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standb Alarm Standby Alarm 2 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.232 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 Location: (2nd Fir Electrical Closet I Volts: 24 VDC Max Panel Current 6.0 Amps Unused 0.000 0.000 0.000 0.000 0.160 Unused 0.000 0.000 0.000 0.000 #14 Solid 2.52 260 1.31 0.000 0.000 Totals 0.000 0.562 U LL SLC 1 15 .30 .30 15 30 .30 30 15 30 .75 .15 15 15 15 4.7k0 © 4 4.7kD 30 V730 r-,75 30 15 15 .30 30 .30 U) 0_ RJ31 X TELCO 120VAC 4.7kf1 ©© 4 30 30 15 15 15 15 .30 15 FIRE ALARM RISER SCALE: N.T.S. , � x� �-" , . - lobal Project Values: SILEI'C Project Name:IPark Ridge Bldg. 1 Standby Hours:/ 24 I KNIGHT Project ID:1 1 Alarm Mins:1 5 I 0.000 Prepared By:ISAL 1 Derating Factor:I 1.2 I 96 Power Expander Calculations'; Date:14/1412014 Voltage Drop Warning , Veon"02 24 09 rsi�w Threshold %-I 10 1 0.000 Panel ID: IPS1 1 Model: 5496 Power Expander Max NAC Current 3.0 Amps Location: (2nd Fir Electrical Closet I Volts: 24 VDC Max Panel Current 6.0 Amps System Sensor P2/PC2 Hom/Strobe (15cd) Part.# Description Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ % Drop Standby_ Alarm & Type 1000 Ft. One -Way Ohms EOL 5496 5496 Pwr Module I 1 0.040 0.160 System Sensor S/SC Strobe (15cd) NAC #1 Notification Appl Circuit 0.000 1.048 #14 Solid 2.52 260 1.31 19.03 6.73% NAC #2 Notification Appl Circuit 0.000 0.860 #14 Solid 2.52 195 0.98 19.55 4.14% NAC #3 Notification Appl Circuit 0.000 0.888 #14 Solid 2.52 205 1.03 19.48 4.50% NAC #4 Notification Appl Circuit 0.000 0.339 #14 Solid 2.52 130 0.66 20.18 1.09% Total Standby Current (Amps) 0.040 3.295 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 0.960 , 0.275 Total Alarm AH Required Total Combined AH Required 1.23 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum BatteryAmpHours Required 1.48 Configure Circuits Print Page 4.7kfl © 0 cL CD A B C D E NOTES: 1 SMOKE DETECTOR 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 PIV 6 DUCT DETECTOR A B C D E FIRE ALARM SYSTEM MATRIX SCALE N.T.S. Confgu roje n ormaon Project Name: Park Ridge Bldg. Prepared By: SAL Project ID: 0 Date: 4/14/2014 Ckt. Number: NAC #1 Panel ID: PS1 Ckt. Name: Notification Appi Circuit Use: Notification Appl Circuit mr F Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.464 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 0 System Sensor P2/PC2 Hom/Strobe (15cd) 0.000 0.091 0.000 0.000 6 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.396 0.000 0.000 Totals 0.000 1.048 Ckt. Number: NAC #2 Panel ID: PS1 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit 'I Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 3 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.348 0 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.000 2 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.182 - 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 0.000 0.000 Totals 0.000 0.860 Ckt. Number: NAC #3 Panel ID: PS1 Ckt. Name: Notification Appl Circuit - Use: Notification Appl Circuit v Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.464 1 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.094 0 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.000 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 0.000 0.000 Totals 0.000 0.888 Ckt. Number: NAC #4 Panel ID: PS1 _ Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Niir Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor P2/PC2 Ham/Strobe (30cd) 0.000 0.116 0.000 0.116 0 System Sensor S/SC Strobe (30cd) 0.000 - 0.094 0.000 0.000 - 1 System Sensor P2/PC2 Hom/Strobe (15cd) 0.000 0.091 0.000 0.091 2 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.132 0.000 0.000 Totals 0.000 0.339 MAli ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: 04-14-14 TENENAT IMPROVEMENT SCALE: N.T.S. DATE03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA1 JOB NO.: OF r 1 1 OFFICPL (15 6-1- B A L -0- £-B B IL 1 Ga J L r 15 A \;J OFFICE O ''CT. \ EY B 11-B 6P -B 0 o A 30 1�----3--- IIA A (P -B - --TO FA B / 30 E B 1 1-B 615 © E.O.L. FILE 0 0 15 O 1' �-B 1 30 TO FA/3 WP75 0 i r, -I n c) cps M TO FA/1 A EN f 'I` A A 30 0- -1-- -- 9'-B 00 1 B I WORK B -E AREA I) T B 15 E.O.L1 i ICE / rr �-A 30 J CE B IB IFFICE 1 SERV A 30 L B L 30 A 30 1 B ._. A 1 D 0- 5 30 A H 15 9-B OFFIC 15 OFFI 3 B L n A -E / WORKAREAL- ---- FIRST FLOOR - FIRE ALARM PLAN SCALE. 1/4'==1,-0" 4-B 3 B J ---QF1 a B 117227 ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: 04-14-14 TENENAT IMPROVEMENT SCALE: 1 /4" = 1'-0" DATE03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA2 JOB NO.: OF OFF B iIC IJ� --------� `I 2-I" fa 1 � 1 B ._. A 1 D 0- 5 30 A H 15 9-B OFFIC 15 OFFI 3 B L n A -E / WORKAREAL- ---- FIRST FLOOR - FIRE ALARM PLAN SCALE. 1/4'==1,-0" 4-B 3 B J ---QF1 a B 117227 ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: 04-14-14 TENENAT IMPROVEMENT SCALE: 1 /4" = 1'-0" DATE03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA2 JOB NO.: OF EXISTING BREAK d1 -B OFFICE OFFICE B r r B 4 SHARED OFFICE 2 ri t B I B 4 —r B 30 OPEN OFFICE A B 1 B-611 STORAGE SUITE 21 ENTRY/WAITING' A 1 L N_ A OPEN OFFICE — _ _'; — J B L B 9 -B n B CONF. B A-1 B 11- B — --- B I SUITE 24 I ENTRY/WAITING B BREAK/ KITCHENETTE B J B SUITE 23 Bk -A 1 OFFICE WOMEN'S R.R. A TO PS1 /3----J SHARED OFFICE OFFICE A --E HALL ( STORAGE TO PS1 t1 STORAGE r 1 1 30 I o (H�--- WO L. J A 1 30 B-'' 30 1 B 1 MEN � A 15 E.0.L. J B 4 TO P S1 /2---1 CP- A `1- B 130 VACANT SUITE 1 STORAGE OFFICE OFFICE 30 —J --EIA ---� 4-B 15 B -`b `P -A 1 30 N._ VACANT SUITE -t B 15 VACANT SUITE 1 (HL `P- B N_ —N 14(? STG. L 30 B 1 6560._ I 9�B J OFFICE OFFICE OFFICE STORAGE E.O.L. OFFICE OFFICE OFFICE OFFICE SECOND FLOOR — FIRE ALARM PLAN SCALE 1/4"=1'-0" 7(227 ELECTRICInc. COMMERCIAL• INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Auburn, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: 04-14-14 TENENAT IMPROVEMENT SCALE: 1 /4" = '-0" DATEb3-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA3 JOB NO.: OF SCOPE OF WORK: Swap out STU transmitter with a digital cellular transmitter. NOTE ON 463 CELL: U.L. approved as primary (standalone) fire communicator ANSI/UL864. Works on digital cellular networks over a variety of carriers. Fully supervised to ensure cellular communication path is intact and functional. Direct reporting to Central Stations DMP receiver. Full transmission of data. Local FACP will send the exact same zones that were on the STU(common alarm, common trouble) to the new DMP cell transmitter Zone 9: General Trouble Zone 10: General Alarm 120 VAC (DEDICATED CKT.) DMP XR100-FC W/ 463C CELL t 9 10 0p BATTERY I BATTERY VICINITY MAP FIRE ALARM RISER DIAGRAM SCHEMATIC: NO SCALE PYROTRON ICS FIRE ALARM CONTROL PANEL Pyrotronics panel monitors the initiating devices. PAID SEP 18 2013 TUKWILA FIRE cc iffy ‘%, WASHINGTONALARM INVESTMENTS ANTEZANA WASHINGTON ALARM INC. 2030 Almon Way South Seattle, WA. 98134 Job # 9772 Drawn by: Mark Mcllwain Ph: 206-328-3288 Fax: 206-322-7214 REVISIONS DATE DESCRIPTION 9/17/2013 PERMIT SET FIRE ALARM FA- 1 CCN.PTED ❑ Without Comments As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire ention Bureau ;e' conformance with current City .-•;derds. Acceptance is subject to errors and Which do not authorize violations of adopted ,dards and ordinances, The responsibility for the _.._ieauacy of design: !eets totally with the designer. ti: ; ionS, defer ix.. or revisions to these drawings after this mate void this acceptance and require a resubimtt o 7'evised drawings for subsequent approval. Final acce_Ttznce is suoj Ct to field test and inspection by T ne Tukwila Fire Fre J r inion Bureau. "I 3 By: _5—i i LN+s,A4.. $"o (Let 45ovc. qct essfoc.- d .4%cg.4 L;r4..4- Lrcc jni 119.5 liand1Le agi.%17 - TUKWILA FIRE DEPARTMEi Please call 205-575-4407 ana give this Fire Permit No. and exact address for shut- down or restoration approval. NOTICE 4 completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector priorto commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure .of test will result in a Re -inspection Fee and termination of the testing ❑ Without Comments 12( As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and i omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void thIs acceptance and will require a resubmittal of revised drawings for subsequent approval, Final acceptance Is subject to"field test and inspection by The Tukwila Fire Prevention Bureau.41^"' Date: Lt ( By: 'IE Retsw-k L.t . O., S ret,i4,1 to,. eiSo.t Ce dloi-.✓to s o - O --- arp w.e4v.3. )(' 176, ,•4- T .17 • rr�,i�•;� w� C� � 1 S Vet,+t'Cx, y- NLrevpc,. hgti�� tla�-„ c d4 t c FAL b►zvi'c� • ho4 o ) .lot/ €k0.17i+,sh1( �,►s a4yl•kia� %G7So,e NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector pilor to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and givee �t it ePermit.No. Ot and exact address for shut- down hutdown or restoration approval. FIRE &SECURITY W w w . Kir 3yelectric.com DESIGNER OF RECORD JOB CONTACTS KIRBY ELECTRIC, INC. GENERAL PROJECT INFORMATION PAUL HOSKINS PAULH©KIRBYELECTRIC.COM DRAWING/DESIGN INFORMATION LEO KOT LEO©KIRBYELECTRIC.COM TECHNICIAN SCHEDULING PAUL HOSKINS PAULH©KIRBYELECTRIC.COM FIRST FLOOR FIRE ALARM PLAN DESIGNER OF RECORD SHEET INDEX KIRBY ELECTRIC, INC. PAGE: DESCRIPTION PHONE: 253-859-2000 FAX: 253-859-2363 FA COVER SHEET FA1 FIRE ALARM DETAIL FA2 FIRST FLOOR FIRE ALARM PLAN FA3 SECOND FLOOR FIRE ALARM PLAN DESIGNER OF RECORD SHAWN LEHMAN KIRBY ELECTRIC, INC. 4826 B ST. NW SUITE 101 AUBURN, WA 98001 PHONE: 253-859-2000 FAX: 253-859-2363 NICET Fire Alarm Level III # 124064 FOR FIRE DEPARTMENT USE ONLY PAID MAR 28 201 TUKWILA F Cc 09r - RE MAST ELECTRICInc. COMMERCIAL• INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Aubum, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: SCALE: N.T.S. DATE 03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET JOB NO.: OF GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTH FORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPEC IRICATIONS, THEY ARE INTENDED AS A CUfflLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm FIRE ALARM LEGEND SYMBOL DESCRIPTION DESCRIPTION 0.000 A FIRE ALARM CONTROL PANEL FACP B HEIGHT FIRE ALARM ANNUNCIATOR FAA 16 GAUGE 4 CONDUCTOR OUTDOOR HORN/STROBE POWER SUPPLY P.S. HORN/STROBE al WALL MNT. FIRE ALARM HORN/STROBE # INDICATES CANDELA RATING CO( - CEILING MNT. FIRE ALARM HORN/STROBE INDICATES CANDELA RATING ;O: WALL MNT. FIRE ALARM STROBE ONLY INDICATES CANDELA RATING 0 CEILING MNT. FIRE ALARM STROBE ONLY # INDICATES CANDELA RATING yn MINI -HORN F FIRE ALARM MANUAL PULL STATION OSMOKE DETECTOR OHEAT DETECTOR 0 HEAT DETECTOR (ABOVE CEILING) Mil DUCT SMOKE DETECTOR Heat ROR BEAM SMOKE DETECTOR BS 0.000 SK BEAM REFLECTOR BR 0.000 DF INPUT MODULE FOR DRY FLOW SWITCH NI INPUT MODULE FOR WATERFLOW SWITCH HL INPUT MODULE FOR HIGH/LOW AIR T INPUT MODULE FOR TAMPER SWITCH 0.405 POST INDICATOR VALVE PIV SK A INPUT MODULE FOR ANSUL (BY OTHERS) 3 INPUT MODULE FOR DUCT DETECTOR IM INPUT MODULE DUAL INPUT MODULE IM2 SK Relaymon 10 INPUT MONITOR MODULE mi[,i' 0.000 R RELAY 4_ END OF LINE RESISTOR (E) EXISTING (R) RELOCATE NOTE: NOT ALL SYMBOLS ARE USED IN THESE DRAWINGS 0.000 GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTH FORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPEC IRICATIONS, THEY ARE INTENDED AS A CUfflLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm WIRING LEGEND DEVICE HEIGHT SCHEDULE DESCRIPTION 0.000 A 14 GAUGE 2 CONDUCTOR DEVICE B HEIGHT (SLC) C 16 GAUGE 4 CONDUCTOR OUTDOOR HORN/STROBE 96" 12 GAUGE 2 CONDUCTOR HORN/STROBE # 80" 0.385 PULL STATION SK 48" FIRE ALARM CONTROL PANEL 60" Ion POWER SUPPLY 0.000 60" SK BELL 29 96" 0.008 ANNUNCIATOR Heat ROR 60" 0.000 0.000 SK GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTH FORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPEC IRICATIONS, THEY ARE INTENDED AS A CUfflLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm WIRING LEGEND Project Name:1Park Ridge Bldg - Dynamic Lang. I Standby Hours:1 24 1 SYMBOL DESCRIPTION 0.000 A 14 GAUGE 2 CONDUCTOR (NAC) B 16 GAUGE 2 CONDUCTOR (SLC) C 16 GAUGE 4 CONDUCTOR (S -BUS) D 12 GAUGE 2 CONDUCTOR (NAC) # CIRCUIT NUMBER 0.385 0.000 SK GENERAL NOTES 1. FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRING MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING AND NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 8. REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 10. ALL WIRING SHALL BE LABELED AND TAGGED. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. DO NOT USE FIRE ALARM CABINET AS TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KIRBY ELECTRIC INC. AUBURN, WA FIRE ALARM SYSTEM INSTALLED BY: KIRBY ELECTRIC INC. AUBURN, WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KNIGHT INC. NORTH FORD, CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KIRBYEIO77BN * THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPEC IRICATIONS, THEY ARE INTENDED AS A CUfflLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA Project Name: Park Ridge Bldg - Dynamic Lang. Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt. Number, PGM -1/0 #1 Panel ID: 5820XL Ckt. Name: Notification App' Circuit I/O Use: Notification Appl Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm SZLEi4T€, Project Name:1Park Ridge Bldg - Dynamic Lang. I Standby Hours:1 24 1 ZG IT Project ID:1 1 Alarm Mins:1 5 1 0.000 Prepared By:'SAL ( Derating Factor.} 1.2 } 5820XL Calculations ; Date:13/19/2014 I Voltage Drop Waming 0.000 Threshold %:1 10 1 0.000 Panel ID: 15820XL I Model: 5820XL Add. Fire Alarm Control Panel Max NAC Current 3.0 Amps Location: 'Main Lobby 1 Volts: 24 VDC Max Panel Current 6.0 Amps System Sensor S/SC Strobe (30cd) Ckt.# Circuit Name Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts © %Drop Standb Alarm & Type 1000 Ft. One -Way Ohms EOL 5820XL 5820XL CTRL Panel 1 0.215 0.385 0.000 SK Photo, Photo -T 97 0.026 0.026 SK Ion 0.000 0.000 0.000 SK Heat, Heat -HT 29 0.008 0.008 SK Heat ROR 19.32 0.000 0.000 SK Beam, Beam -T 0.888 0.000 0.000 SK Duct 19.24 0.000 0.000 SK Acclimate 0.405 0.000 0.000 SK Control 20.08 0.000 0.000 SK Control -6 0.000 0.000 SK Relaymon 0.000 0.000 SK Monitor, Minimon 0.000 0.000 SK Monitor -2 0.000 0.000 SK Monitor -10 0.000 0.000 SK Pull -SA, Pull -DA 12 0.005 0.005 SK Relay 0.000 0.000 SK Relay -6 0.000 0.000 SK Zone 0.000 0.000 SK Zone -6 0.000 0.000 SK Isolator Module 0.000 0.000 SSB224B1 Isolator Base 0.000 0.000 B200SR Sounder Base 0.000 0.000 SSB224R6 Relay Base 0.000 0.000 SSRTS151 Magnetic Remote Test 0.000 0.000 SSRTS151KEY Key Activated Test 0.000 0.000 SSRA100Z Remote LED 0.000 0.000 5815XL SLC Loop Expander 1 0.055 0.055 5860 LCD Remote Annunc 0.000 0.000 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 1 0.010 0.010 5895XL Power Expander 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 PGM -1/0 #1 Notification Appl Circuit 0.000 0.800 #14 Solid 2.52 260 1.31 19.35 5.14% PGM -I/O #2 Notification Appl Circuit 0.000 0.559 #14 Solid 2.52 180 0.91 19.89 2.49% PGM -I/O #3 Notification Appl Circuit 0.000 0.960 #14 Solid 2.52 250 1.26 19.19 5.93% PGM -1/0 #4 Notification Appl Circuit 0.000 0.562 #14 Solid 2.52 180 0.91 19.89 2.50% PGM -I/O #5 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% PGM -I/O #6 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% Total Standby Current (Amps) 0.319 3.370 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm lime In Minutes / 60 (5 Mins) Total Standby AH Required 7.644 0.281 Total Alarm AH Required Total Combined AH Required 7.93 Command Shortcuts Multiply By The Derating Factor 1.20 9.51 Configure Circuits Print Page Minimum Battery AmpHours Required Project Name: Park Ridge Bldg - Dynamic Lang. Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt. Number, PGM -1/0 #1 Panel ID: 5820XL Ckt. Name: Notification App' Circuit I/O Use: Notification Appl Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.264 3 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.348 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 3 Unused 0.000 0.000 0.000 0.000 #14 Solid 2.52 290 1.46 0.000 0.000 Totals 0.000 0.800 Ckt. Number. PGM -I/0 #2 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.094 1 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.176 1 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.091 3 System Sensor S/SC Strobe (15cd) 0.000 0-066 0.000 0.198 #14 Solid 2.52 290 1.46 0.000 0.000 Totals 0.000 0.559 Ckt. Number. PGM -I/0 #3 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit v Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.464 1 System Sensor P2/PC2 Hom/Strobe (75cd) 0.000 0.176 0.000 0.176 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 2 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.132 #14 Solid 2.52 290 1.46 0.000 0.000 Totals 0.000 0.960 Ckt. Number: PGM -I/0 #4 Panel ID: 5820XL Ckt. Name: Notification A I Circuit I/O Use:' Notification ation Appl Circuit Nri Qty Device Current Draw Each Current Draw Total Standby Alarm. Standby Alarm 2 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.232 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 Location: 12nd Floor - Phone Closet 1 Volts: 24 VDC Max Panel Current: 6.0 Amps Unused 0.000 0-000 0.000 0.000 0.160 Unused 0.000 0.000 0.000 0.000 #14 Solid 2.52 290 1.46 0.000 0.000 Totals 0.000 0.562 15 .30 .30 15 30 .30 30 15 30 15 15 15 15 .30 15 V) 0 PS1 RJ31X TELCO 120VAC 30 4.7k0 4.7kri 30 30 15 .30 30 15 15 15 15 II II II II IRI I) (o;l FIRE ALARM RISER 30 15 SCALE N.T.S. 4.7kQQ A B C D E NOTES: 1 SMOKE DETECTOR 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 PIV 6 DUCT DETECTOR A B C D E FIRE ALARM SYSTEM MA TR1X SCALE N.T.S. [Project Name: Park Ridge Bldg. - Dynamic Lang Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt- Number. NAC #1 Panel ID: PS1 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Iv t Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm .S1 Project Name:'Park Ridge Bldg. -Dynamic Lang► Standby Hours:L 24 ( KNIGH t ProjectlD:1 I Alarm Mins: r 5 1 0.000 Prepared By:}SAL 1 Derating Factor:L 1.2 1 5496ower pander Calauiahons� � e Date:13/19/2014 I Voltage Drop Warning ,.n,2 24.0 Version 02 24 09 Threshold %: 1 10 1 0.000 Panel ID: IPS' 1 Model: 5496 Power Expander Max MAC Current: 3.0 Amps Location: 12nd Floor - Phone Closet 1 Volts: 24 VDC Max Panel Current: 6.0 Amps System Sensor S/SC Strobe (30cd) Part.# Description Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ a/Drop Standby_ Alarm & Type 1000 Ft. One -Way Ohms EOL 5496 5496 Pwr Module 1 1 0.040 0.160 Unused NAC #1 Notification Appl Circuit 0.000 1.048 #14 Solid 2.52 290 1.46 18.87 7.51% NAC #2 Notification Appl Circuit 0.000 0.860 #14 Solid 2.52 250 1.26 19.32 5.31% NAC #3 Notification Appl Circuit 0.000 0.888 #14 Solid 2.52 260 1.31 19.24 5.70% NAC #4 Notification Appl Circuit 0.000 0.405 #14 Solid 2.52 155 0.78 20.08 1.55% Total Standby Current (Amps) 0.040 3.361 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 0.960 0.280 Total Alarm AH Required Total Combined AH Required 1.24 Command Shortcuts Multiply By The Derating Factor 1.20 1.49 Configure Circuits Print Page Minimum Battery AmpHours Required 4.7kQQ A B C D E NOTES: 1 SMOKE DETECTOR 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 PIV 6 DUCT DETECTOR A B C D E FIRE ALARM SYSTEM MA TR1X SCALE N.T.S. [Project Name: Park Ridge Bldg. - Dynamic Lang Prepared By: SAL Project ID: 0 Date: 3/19/2014 Ckt- Number. NAC #1 Panel ID: PS1 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Iv t Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 • 0.000 0.464 6 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0,396 2 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.188 5 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.048 Ckt. Number NAC #2 Panel ID: PS1 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 3 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.348 2 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.182 0 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.000 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 0.000 0.000 Totals 0.000 0.860 Ckt. Number. NAC #3 Panel ID: PS1 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.464 1 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.094 5 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.330 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.888 Ckt. Number: NAC #4 Panel ID: PS1 Use:, Notification Appl Circuit Ckt. Name: Notification Appl CircuitUse: Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.116 1 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 - 0.000 0.091 3 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.198 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.405 MEET ELECTRICInc. COMMERCIAL• INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Aubum, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: SCALE: N.T.S. DATE03-18-14 DRAWN BY: L.K. CHECKED BY: S.L. SHEET FA1 JOB NO.: OF ?- —1 • f 5 B B 6.13, A +—B LHL4 1 A B 1 30 B B —+ ) 15 OFFICE •••••• +—B \— — —0•TO F/A/4 A +—B 15 ---..T0 FA/1 A fL A 1 30 65 E.O.L. OFFICE d_A 0 1 —f1N- A +—B WORK AREA B-4 30 B 0- +— A 30 1—A 30 1 _ 1 B TO FA/2-.-- 443:00 B 30 30 coa C 0 N r- E 1—B SE R a VJO R A AV \REA B 4 - B— J ch or J WORK AREA B B 1 emmoomm... 11 15 30 1 9—B I -r ) J 115 15 4—B 1 —f ck—B OFFICE FIRST FLOOR — FIRE ALARM PLAN SCALE 1/4'=1 =0" r UP 11111BY ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Aubum, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 REVISIONS: SCALE: 1/4" = 1 '-0" "1E03-18-14 DRAWN BY: L.K. NECKED BY; SL SHEET FA2 JOB NO.: OF STAFF 1 OFFICE B B OFFICE B B B 30 A B 1 F 30 L B 4- 1 A r- 30 --1 E0.L. 1 1 A 30 n 4 jnizna. I L, r=nnt Agn.% B 9—A B _r OFR - 30 9' A A r B —+ STORAGE B B 30 WORK AREA B q3.00(11) —Et [--.-TO PS1 /4 B 1 1 •,••••••• 1 A --- B 30 A V\/OM B 1 15 LA 1:7 411 1— A k rt; 5 E.O.L. no% e 1' B TO PS1 B / 30 15 TO PS1 /3-- 1 Th 3 B-11 OFRCE 15 OFFICE B 30 15 A A OFFICE B OFFICE Et B +— B TO PSI 1 +— A (HL\ -r B --a STG. +— B 1 A B B B WORK A AREA — 0Frd,Lr: I 1—B 1 30 63 tonaat B —E 61 OR Ef— B 1 A —+ 30 y co; E. O. L. A A B -------.., Li r= r 2i i7 OFFICE B — 4E1 - B OFFICE — — OFF CP 15 1— A B ••••••••, J 30 A -4B if DN OFFICE SECOND FLOOR - FIRE ALARM PLAN SCALE Ve=1 2 0 mar ELECTRICInc. COMMERCIAL- INDUSTRIAL www.kirbyelectric.com 4826 "B" St. NW Suite 102 Aubum, Washington 98001 (253) 859-2000 (FAX) 859-2363 PARK RIDGE BUILDING DYNAMIC LANGUAGE PARK RIDGE BUILDING 15215 52ND AVE S SEATTLE, WA 98166 11 1 1 1 REVISIONS: SCALE: 1/4" = 1 '—tr DATEO3-18-14 DRAWN BY: L.K.s CHECKED BY:e SHEET FA3 JOB NO.: OF