HomeMy WebLinkAboutPP - 15455 53RD AVE S - SEATAC LIGHTING - PERMITS AND PLANS15455 53RD AVE S ASSOCIATED PERMITS D19-0275 D17-0199 18-F-030 18-S-041 40W1,44 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 15455 53rd Ave S Tenant Name: Seatac Lighting Property Owner's Name: Seatac Liqhtinq King Co. Assessor's Tax No.: 115720-0044 Suite Number: Floor: New Tenant? © - Yes ❑ - No Mailing Address: 15455 Tukwila Wa 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Kevin Ullrich Day Telephone: 253-569-6917 Company Name: Abacus Electric Co Mailing Address: 3401 12th St E Fife Wa 98424 kevin@abacuselectricllc com City State Zip . E-mail Address: Fax Number:2 5 3— 9 8 4 —1613 NICET III number: 093706 Contractor's City of Tukwila Business License number: BUS -0993200 Total number of new/relocated devices or sprinkler heads: (41) tot al new devices Valuation of Project (contractor's bid price): $ 15,000.00 Scope of Work (please provide detailed information): Installation of all new Fire Alarm System for new tenant layout PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: UTHORIZED AGENT: Print Name: Kevin Ullrich Plan Permit App.doc Date: 1/22/2018 Day Telephone: 253-569-6917 8/22/14 TFD FP Form 8 1 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Permit No.: Date: Reviewer: Seatac Lighting 15455 53rd Ave. S 18-S-041 March 6, 2018 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. A • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Z,19- PIERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:. ----N zei/LA, Type of Inspection: Hood & Duct: Address: Suite #: / "sr 6.' ''2$ Contact Person: Special Instructions: Phone No.: IQD Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: /'1. -/ -64".€ lA ,i" o Pa ht s ti4 - ori �F A6t..I•125g C - /Veer' Rkity bemx , cd.g-c4-%\,z+ K-02- 114.10 r - ).- CAI --e # �iv Li,_ rt,liN► Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:` 4 Date: ..0/azo Hrs.: / d $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project��G ( c1411,”Type of Inspection: F(1\1/1-1. Address: Suite #: /4 s-'�Ait. Contact Person: Special Instructions: Phone No.: ak#A;proved per applicable codes. I I Corrections required prior to approval. COMMENTS: p.zta- �l✓t�t,� a r(e.‘ ri,art.-- 01Z e(23 e--&f/P 7 Needs Shift Inspection: 7 Sprinklers: fIA Fire Alarm: Ai Hood & Duct: -FS Monitor: ► 1z -river; ,L( j✓ ' Pre -Fire: Permits: I CrC�141-- Occupancy Type: 1g Inspector: I fIA Date: 21, 2Jl) Hrs.: ' `7 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit _p»^ 0 iic PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: /'' #rci.e's r Type of Inspection: /c;hL;:i Address: Suite #: / SYS3" 53 Ave S, Contact Peri6i / Cer_off Av..-,47,e_ Special Instructions: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: / /'' #rci.e's Fire Alarm: Hood & Duct: Monitor: Pre -Fire: #:-‘4.01.,_ ryii, — R.o.er,,v„,141 / Cer_off Av..-,47,e_ frirole-Yt4/ -- / e( 3 — V .0 Aver -- 6,e -i -r .41. C ' . ./ 66✓14. Yl Ny4e1 i — 72G,,c /Jag 6~Qa-f` 1 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: A 5-7 Date: 7/./0,//g Hrs.: r• U ,r„", . / / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F,D. Form F.P. 113 ✓/ INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:-, t� Type of Inspection:1c,,/„..5 ,/� Address: Suite #: i c3 /fro_ Contact P n: Special Instructions: , Phone No.: Pre -Fire: I Approved per applicable codes. nCorrections required prior to approval. COMMENTS: Date: Sprinklers: r.,, Fire Alarm: or 0 //4.1)414.,/ /vim,ire iivt Monitor: , — -04. Pre -Fire: .s./„, iv eftve_i .-- A/ ti Ail/ 04 vim- 6 ---- r. -,..414e- Adetzav,t. , 4-).4,( j A f/ -- eioAr, trY-- 1//_S" I S Needs Shift Inspection: Date: Sprinklers: r.,, Fire Alarm: or 0 Hood & Duct: Monitor: - - Ai 0.4 it, Pre -Fire: Permits: Th. "1 S -Z- 2Y q o Occupancy Type: Inspector:?z AI 6:3 Date: 7// p ii t Hrs.: / .. 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 CORRECTION NOTICE/REINSPECTION FEE Inspector: Permit number: TUKWILA FIRE MARSHAL'S OFFICE Office: 206-575-4407 Fax: 206-575-4439 Email: Fire Marshal@tukwilawa.gov Business Name: / Type of Inspection. 400 f Location Address:/ !, 63 AVIS Date : 7/6k / / A Contact Person : X ci.t.,.447 , Phone No.• zs,-.s-7.3as ACTION REQUIRED l'Ali' cAt / ea° — ---- A&wit. Lott_ ',0,,,,k(ed- p,„,t, -,zo c -,-,,414w Ai/nt ci.t.,.447 ta fir/ At 4. -ft u.vai.- nii Pco-vi e6 36 .i afr•-,./ee A,,g,i. 40 Mete flC ni/L/(4\1\12 1 _ CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY : FAILURE TO COMPLY MAY RESULT IN THE ISSUANCE OF A CRIMINAL CITATION/TICKET. Billin ailing Address : Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Reinsp Fee2.doc Revised 6/17/14 T.F.D. Form F.P. 100 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 5e64_,FacHi S Type of Inspection Address: Suite #: '4-S Fire Alarm: 4\h2 �, Contact Person: Special Ins ructions: Monitor: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: �.V. 5 Hrs.: Fire Alarm: kta.a5 ak_ ID cq I Monitor: Pre -Fire: 'EzN.. s/ Permits: re -D, 477--)e 7 ..c: I? 4.r -A --e— I 7 5w'p 19-7/t.-- ()rt ,1 -e-& d S 0-1+i--- w/ /vim -3 0_ A /P661- 17£G✓ alit C- ig Needs Shift Inspection: Sprinklers: �.V. 5 Hrs.: Fire Alarm: kta.a5 Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: g Inspector: 1 5-`4 Date: (o/ 2.q( r Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 A INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit DV7 _D\c / S --s -041 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Type of Inspection: .-.a- ,o 9--IA.r-1.. La C-uv.e. r Project --LF` LIgt411,13 Address: Suite #: / 51.55 -53 °114N..S Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: yslco RtriV". � Q oo�ZQ5fSr�,", Occupancy Type: 7(L (43.70 Q 705 Ps1 0E-6 Cromtic Lia 1 r, 134,ketibrvks or.L. -xl-k_`"'n 1 cA. ov, - . r A.. S{J.r:- L..,. t.t< °i,S 1 t,rtiw Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ti7-sf‘&V Date: ( p-1 (g Hrs.: Z, $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 TUKWILA FIRE MARSHAL'S OFFICE '440 Phone: 206-575-4407 • Email: FireMarshal dtukwilawa.gov CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date 6Ja5I it Permit # t " F - () 3) Property Address 15 4 55 5 3 ra Ave. S Suite # City TUKWILA Zip Code qg t gg Name of Facility Tot W3 Occupied as c2,r421:wc\n\;v- Owner or Representative Phone # Installing Company A1a64...4,L6 Ehcc�tticr Installing Contractor's Address 3401 I2++' SA- City +Cit}- Phone # ;63- 9g LI -IC 11 Installer's Name (PRINT) bcv;c1 CL61.41(c.rel License and/or Certificate L L 01 C,1-iOlCl1 5330Q General Contractor Co\iog Coe• -s Electrical Contractor A10,...cL..4EL c k_ FACP Equipment Manufacturer ?o tkr- Model # Ipts,-"(oo° This system has been installed. pre-testid and operates in accordance with the standards listed below and was inspected by k CLe vuWQ� On (date) 7/10/N and includes the devices listed on back. Circle all that apply: ✓/ NFPA 72, Chapter 1 2 4 5 6 7 and/or IFC SEC 907 ✓ NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions LManufacturer's Instructions / Other (specify) ✓ Tukwila City Ordinance Numbers 2050. 2051 UL Central .tion MIonit .ut , c-4 _ .vste is monitored b� Atc.rw, Cxx s wAC.. SIGNE6,LJ lam_ Date 7—iv-l$ Syst�Vrmware: ?.,NKr F: rt.- .. v..\ ero ,r^ry r' Installed version (4.03.0 Checksum Date 6 1/ (i? Initial program Installation Date Revisions and Reasons 7ftotl% Programmed by -Do,34 CL,ik„ , EQUIPMENT INSTALLED AND TESTED: Control Panel 4 of Manual Station of S Smoke Detectors A_ of —�-- Heat Detectors of Duct Detectors of I� tg A/V Devices eKofit Audio Devices ofJ Visual Devices 2_ of Auto Door Release of Trouble Indictors of Batteries Readings Battery a G . g Generator of HVAC Controls of Fire Alarm Dialer of Monitored by Make/Model POAAfS 000 Make/Model ?Alms ?kb 100 - ?SSA Make/Model Poi -kr btz)- ?t Make/Model Make/Model Make/Model �• NS-wki / CNS Make/Model l'eWcr- (1,,k A- 09 Intl Make/Model ?ok&s S— 1y WW /.61116 C.S -,;(4 wtA) Make/Model Make/Model Full Load a4. Make/Model Make/Model Make/Model Charge 'I.31 V Annunciator of Make/Model Sprinkler System. (Fire Alarm connections only) Water Flow Sw. Valve Tamper Sw. PIV Elec. Alarm Bell 1 of ( of of of Make/Model i'. cs PS to -a. Make/Model # F Q 36 Make/Model Make/Model Automatic time Delay of Water Flow Alarm seconds. None Installed Do you eet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes No Test of alarm System on emergency power, satisfactory? Yes / No Test Witnessed by cS Ls4.; . C- ��4►{1 Title rel) Date 7—/p -/ Comments: Fire Alarm Certificate.doc Revised: 6117/I4 TFD FP Form 110 4 , Ir It EXISTING PIV TO REMAIN IN ITS CURRENT LOCATION REMOVE THE EXISTING UNDERGROUND DETECTOR CHECK EXISTING 8' UNDERGROUND WATER MAIN 53RD AVE. S Io ' REMOVE THE EXISTING REMOTE FDC EXISTING FIRE SPRINKLER RISER SEATAC LIGHTING L_J 53RD AVE. S HIGHWAY 581 EXISTING FIRE SPRINKLER RISER LOCATION NEW MOUNTED STORZ FDC SITE PLAN SCALE: NT5 SITE PLAN SCALE: NTS HANGER SPACING CHAR T IXIE 8221 MAXIM MACE EVISEN HAWN -111) 92E - 3/4 1 1-1/4 1-1/22 f7 2-1/2 3 4 6 S7 Z L' N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 DREADED N/A 120 120 120 120 — 1 -bar �,' SKYLIGHT \��" N N 1• o 5— — -©- — — 12-0 0 TYP. -5 - �- _0 J2 — o fl F - I. a la 1-61 l 120 120 N/A N/A 80 80 10 0 10 0 12 0 12 0 15 0 15 wvrRzat 12-0 0 4 WAVEROM SRSIUR 8) 1,�� • • • • • • ME OBE CR ZIP ORE MEOW ADD RE OEM' MI J8' RP Y SEAM NAV 48"RDg/)/."'- AMERMN8C RD 11y a LA WEED RE P3 DE MVP= WM EBBW LOST Mtn tI FE MUCH WSW marsrma ER SEN AMER GA rt WC RPM ME" POSEN BE DEE LtL21 MATER ACD MS I. f'IFE9S ME OF REV H E'SE MAIL Or ND LlhRI AM) 46 3, 8AND 8. 1%1'AtTLWRO GENERAL NOTES SYSTEM COMPONENTS 01. AUTOMATIC SPRINKLERS CHARACTERISTICS SHALL BE QUICK RESPONSE SEE SPRINKLER LEGEND FOR SPRINKLER PROPERTIES 02. PIPING FOR BRANCH ONES TO BE EXISTING BLACK SCHEDULE 40 03. PIPING FOR CROSSMAIN ONES TO BE: DOSING BLACK SCHEDULE 40 04. JOINING OF BRANCH ONES PIPING TO UTILIZE: EXISITNG BLACK CAST IRON 05. JOINING OF CROSSMAINS TO UTILIZE EXISTING GROOVED MECHANICAL FITTINGS & COUPUNGS 06. HANGERS SHALL UTILIZE: SAMMY WOOD SCREW. ALL THREAD ROD. & NOMINAL SIZED RING SEE HANGER DETAIL(S) THIS .SHEET 07. CONTROL VALVE(S) TO BE: EXISTING PIV 08. SPRINKLER SYSTEM ALARM SIGNALING DEVICE TO BE: EXISTING WATER MOTOR GONG SYSTEM REQUIREMENTS 01. SYSTEM DESIGN CRITERIA FOR SPRINKLER SYSTEM: EXISTING ORDINARY HAZARD PIPE SCHEDULE SYSTEM SYSTEM EXCLUSIONS 01. WIRING OF ELECTRICAL ALARM SIGNALING DEVICES 02. PAINTING OF NEWLY INSTALLED PIPE AND COMPONENTS. 03. PATCHING AND/OR REPAIRING CEIUNG OR WALLS. 04. ADEQUATE HEAT ABOVE CEIUNGS. 05. MODIFICATIONS TO THE EXISTING SEISMIC BRACING. OPEN WORKSTATIONS eF2 144 OFz OPEN WORKSTATIONS BUILDING INFORMATION: PARCEL #: 1157200044 OCCUPANCY GROUP: B TOTAL SQ. FT.: 20,524 BUILDING OWNER'S INFORMATION: JOHN BORELLI SEA -TAC LIGHTING AND CONTROLS 4439 SOUTH 134th PI BUILDING E TUKWILA, WA 98168 (206) 575-6865 SCOPE OF WORK: • ADD AND RELOCATE SPRINKLERS HEADS TO ACCOMMODATE THE NEW WALLS AND CEILINGS. • • REPLACE THE EXISTING EXPOSED SPRINKLER HEADS WITH NEW QUICK RESPONSE SPRINKLER HEADS. • INSTALL A NEW DERINGER 30 (X) BACKFLOW PREVENTER ON THE EXISTING RISER. • • INSTALL A NEW WALL MOUNTED 5" STORZ FDC. • REMOVE THE EXISTING REMOTE FDC AND DETECTOR CHECK. • NO WORK IS TO BE DONE TO THE EXISTING DRY SYSTEM THAT FEEDS THE FRONT AND BACK CANOPIES. SPRINKLER LEGEND N = REPLACE THE EXISTING HEAD WITH QR R = NEW QR RELOCATED SPRINKLER HEAD A = NEW QR ADDED SPRINKLER HEAD P = PLUGGED SPRINKLER HEAD — — — — — — = EXISTING PIPE = NEW PIPE DETAIL A 5CALE: NT5 4 0 Without Comments As Noted ,n Red .71. -Per The Attached Letter Thes-rp1ans have been reviewed by The Tukwila Fire ?re"en rtion Bureau forconforrnarce with curr standards. Acceptance is subject- to errors a o;nissL)ns which :Oi authorize violations of adopted ,':mdarrs and.7Pporcrr nces. The responsibility for the „1egLede cy of s'q t }?' ;:s totally/ .with the designer. deletion- . ; -visions to these drawings after -r!s date will '•:;ld tl-)!z_ acceptance and will require a r e zubmlttai of r v sed irawings for subsequent approval. '4 F incl acceptance is subject to Held test and ll The Tukwila Fire Prevention Bureau. Date:By: ice`^ S � 1 N 5 — ri 12-0 F2 1•431-7.1 I-8.1 CLOSET 106 N 1' TYP. 16-73€ lin .- .-"o OPE! -� MEETII #N ' • .' 1'4 k 103 2-1 1-1 , — 1 -bar �,' SKYLIGHT \��" N N 1• o 5— — -©- — — 12-0 0 TYP. -5 - �- _0 J2 — o fl F - I. a la 1-61 l J 42-1 RfR00M TO WET SYSTEM ELEV. I I' -G" 7 / / / / / / . EXISTING WATER MOTOR GONG (N) 8x4' MACH T 4' GROOVED CHEC VALVE TO FRONT AND REAR CANOPI 4' DRAIN 90 TH 1/2' BALL DRIP EXISTING 4' DRY PIPE VALVE EXISTING VALV8' ALARM E / / / / / / / / / / SPRINKLER BRANCHUNE. 1' PIPE WITH 1' CI SCR 90 MADE -ON (UST BY UNE -INSTALL AT ROUGH -IN). " 054Y VALVE N N STORAGE 1' ARMOVER COJ PIPE ' 1' CI SCR 90 10 DROP WITH 1x1¢ REDL..ER MADE -ON, TO BE COJ 4'90 4.90 EXISTING COMPRESSOR SHOWN FOR ILWSTATION PURPOSES ONLY NEW 8' DERINGER 30 00 DCDA-II • (N) FLGx▪ GRV PCS REMOVE EXISTING 8" SPOOL PCE. T1JKWILA FIRE NPARTMMT eye se call 205-575-4407 and this Alpe Permit NO. 'LJ exact address for shut Or festoratlon approves + WATERFLOW DETECTOR JFFICE ©moo - 180 I A FIRE SPRINKLER PLAN fl? tI f ,._ ... _ a..;1111111111111.111.1111111111 SCALE 1/8=1'-0' FIRE SPRINKLER PLAN SCALE: NT5 0 (N) FLGxGRV PC5 EXISITNG 8' DUCTILE IRON. •IG's'dIKNOTON STATE CIEWWICATB OF coswarsocy $YSTEDIS Michael Maguire 1440-0791-C Level 3 Archer. nstruction, Inc. ARCHE*21 R EXISTING RISER ROOM/SECTION VIEW SCALE: NTS (E) GRADE REVISIONS DATE DESCRIPTION BY A HANGERS BEAM CLAMP W/ RETAINING STRAP 1-24-18 PER CARL ANDERSON REVIEW MM B SIDE BEAM BRACKET AREA NUMBER CODE HYDRAULIC DESIGN INFORMATION [HAZARD SYSTEM TYPE . C EYE SOCKET D NUT & PLATE WASHER E KWIK BOLT REMOTE AREA SQ FT. DENSITY GPM/SQ. FT. INSIDE HOSE ALLOWANCE OUTSIDE HOSE ALLOWANCE AREA PER SPRINKLER F HDI -P G SAMMY SIDEWINDER TOTAL SYSTEM REQUIREMENTS: H SAMMY SUPERSCREW HYDRAULIC DESIGN INFORMATION J COACH SCREW ROD K CEILING FLANGE AREA NUMBER CODE I HAZARD SYSTEM TYPE L U -HOOK M N SHORT STRAP WALL BRACKET REMOTE AREA SQ. Fr. DENSITY GPM/SQ. FT. INSIDE.HOSE ALLOWANCE OUTSIDE HOSE ALLOWANCE AREA PER SPRINKLER P TRAPEZE TOTAL SYSTEM REQUIREMENTS: ABBREVIATIONS WATERFLOW INFORMATION AFF BTS BOD BOJ BOP BOT CTS FO IFOW NAS OTS UNO ABOVE FINISHED FLOOR STATIC BOTTOM TO STRUCTURE BOTTOM OF DECK RESIDUAL BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL NO AUTO. SPRINKLERS OPEN TO STRUCTURE UNLESS NOTED OTHERWISE RIGID COUPLING FLEXIBLE COUPLING XX PSI XX PSI GPM FLOWING XXXX GPM DATE & TIME PER: XX/XX/XXXX SPRINKLER SYMBOLS RC SYM MAKE MODEL SIN# TYPE FINISH THREAD ORIFICETEMP CANOQTY C) • GLOBE GL6601 PEND CHROME 1/2 1/2' ; " CEROPY LOCATION: NOTES: MEI TOTAL PROJECT SPRINKLERS = TOTAL SPRINKLERS THIS SHEET 209 HE • CONSTRUCTION, INC SEATAC LIGHTING PIPING PLAN FIRE SPRINKLER DIVISION 7855 5 206TH STREET, KENT, WA 98032 PHONE 253-872-7222 FAX 253-872-7277 15455 53rd Ave. S. TUKWILA, WA. 98188 PERMIT NO: - JOB NO: 817-143 AUTHORITY: CITY OF TUKWILA PAID FE3 23 2CWW TUKWILA FIRE 30v DESIGNER: MIKE SCALE: NOTED DATE: 2-9-18 REVISED 2/9/18 PLOTTED / / FP 1 OF 1 • Without Comments YE' As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which Ccs not authorize Violations of adopted standards - . a Lir dt<:ances, The responsibility for the adequacy of desiral`, r.$1' totally with the designer. Additions, deletions o < visions to these drawings after this date will void tr-ii;- ,;_,.eptance and will require a resubmittal r,f t-,�vi=, ..) .r,,vings for subsequent approval. Final acceptance 'Pi. suojecr to field test and inspection by The Tukwila Firs: Prevention i Bureau. Date: D- " L g E;y: Chs�,n w�ghvwi poi 3.-1-c.4'i.oh.3 or -i- J e41C-Ize exv)-s. :1:v1.$44 loreakt. 1'4.1dile z.tu‘»p ol, darA 6'eaktr, -X hill Q�a✓C,� ,r W P be 07.54,0 c. caeo,S-c'r>..e , 4cc-eSJ t TUKW' l A FRE " 'SEP ^ RTMEN cafi 206-5154107 aria give, this F i3'e Permit No. c�-F -030 ':Xiexact address for shut S loVVn or restoration appr,ovale FIRE ILJFtI I_ 71- oa 88 Fire Alarm Symbol Legend SYMBOL DEVICE MOUNTING DETAIL PART NUMBER QUANTITY FACP IPA -4000, 4064 POINT RELEASING FACP IPA -4000 // ///, ROOF DECK // / /�,% / 7//// \ / � / / /////1/ s: PHOTO SMOKE DETECTOR -►'T' '!'iv, MOUNT TO 1 F ` �. PAD100-PSSA 1 z DUAL INPUT CONTACT MODULE PAD100-DIM STRUCTURE / i BASE .w.� HEAD 3 -BOX // ABOVE CEILING DEVICE SUPPORT BRACKET \' 110CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 1 .\ 30CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 4 75CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 13 30CD STROBE, M -C, WHITE, WALL • S-24WW 6 15CD STROBE, M -C, WHITE, WALL S-24WW 14 PLASTER RING STROBE, M -C, RED, WALL CEILING 1 POTTER ELECTRIC SIGNAL �'*K -� MBA -624 1 BASE HEAD SMOKE OR HEAT DETECTOR EOL 5.1K EOL -5.1 HORN/STROBE POTTER ELECTRIC SIGNAL EOL -5.1 SEND SUPERVISORY SIGNAL TO C.S. MONITORING SEND WATERFLOW SIGNAL TO C.S. MONITORING \\ ILLUMINATE LED ON DETECTOR MANUAL PULL STATION BACK MOUNTED WALL /, / BOX TO FRAMING Lwr �. FIRE ALARM ® 80" 48" ,_,- ,_^ j,.^ 1 • • Without Comments YE' As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which Ccs not authorize Violations of adopted standards - . a Lir dt<:ances, The responsibility for the adequacy of desiral`, r.$1' totally with the designer. Additions, deletions o < visions to these drawings after this date will void tr-ii;- ,;_,.eptance and will require a resubmittal r,f t-,�vi=, ..) .r,,vings for subsequent approval. Final acceptance 'Pi. suojecr to field test and inspection by The Tukwila Firs: Prevention i Bureau. Date: D- " L g E;y: Chs�,n w�ghvwi poi 3.-1-c.4'i.oh.3 or -i- J e41C-Ize exv)-s. :1:v1.$44 loreakt. 1'4.1dile z.tu‘»p ol, darA 6'eaktr, -X hill Q�a✓C,� ,r W P be 07.54,0 c. caeo,S-c'r>..e , 4cc-eSJ t TUKW' l A FRE " 'SEP ^ RTMEN cafi 206-5154107 aria give, this F i3'e Permit No. c�-F -030 ':Xiexact address for shut S loVVn or restoration appr,ovale FIRE ILJFtI I_ 71- oa 88 Fire Alarm Symbol Legend SYMBOL DESCRIPTION PART NUMBER QUANTITY FACP IPA -4000, 4064 POINT RELEASING FACP IPA -4000 1 s: PHOTO SMOKE DETECTOR PAD100-PD 1 F ` PULL STATION, SINGLE ACTION, ADDRESSABLE PAD100-PSSA 1 - 1 D DUAL INPUT CONTACT MODULE PAD100-DIM 3 \' 110CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 1 .\ 30CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 4 75CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 13 30CD STROBE, M -C, WHITE, WALL • S-24WW 6 15CD STROBE, M -C, WHITE, WALL S-24WW 14 75CD STROBE, M -C, RED, WALL S-24WR 1 POTTER ELECTRIC SIGNAL 6IN VIBRATING FIRE BELL 24V RED MBA -624 1 , EOL R° EOL 5.1K EOL 5.1K EOL -5.1 5 FIRE ALARM CABLING LEGEND CODE CABLE LINETYE CIRCUIT TYPE MANUFACTURER PART NO. CABLE TYPE A IPA -4000, 4064 POINT RELEASING FACP INITIATING DEVICE CIRCUIT BELDEN 5320UL 18/2 FPLR B IPA4000_MB NOTIFICATION APPLIANCE CIRCUIT BELDEN 5120UL 14/2 FPLR C • AUXILIARY DEVICE CIRCUIT BELDEN 5120UL 14/2 FPLR D PAD100-6B REMOTE ANNUNCIATOR CIRCUIT BELDEN f 5320UL, 5120UL 18/2 FPLR, 14/2 FPLR 3 Bill of Material Qty. Description Manufacturer Part No. 1 Panel: FACP 1 IPA -4000, 4064 POINT RELEASING FACP POTTER ELECTRIC SIGNAL IPA -4000 1 IPA4000_MB POTTER ELECTRIC SIGNAL IPA4000_MB 1 PHOTO SMOKE DETECTOR POTTER ELECTRIC SIGNAL PAD100-PD 1 6" ADDRESSABLE BASE POTTER ELECTRIC SIGNAL PAD100-6B 1 PULL STATION, SINGLE ACTION, ADDRESSABLE POTTER ELECTRIC SIGNAL PAD100-PSSA 3 DUAL INPUT CONTACT MODULE POTTER ELECTRIC SIGNAL PAD100-DIM 18 HORN/STROBE, 2 WIRE, M -C, RED, WALL POTTER ELECTRIC SIGNAL HS-24WW 20 STROBE, M -C, WHITE, WALL POTTER ELECTRIC SIGNAL S-24WW 1 STROBE, M -C, RED, WALL POTTER ELECTRIC SIGNAL S-24WR 1 6IN VIBRATING FIRE BELL 24V RED POTTER ELECTRIC SIGNAL MBA -624 5 EOL 5.1K POTTER ELECTRIC SIGNAL EOL -5.1 rrternational. Buddha D.ynarrric Lan guage,Centet LoNIst.a Apartments pit us Cradit Un( F P Office Sniutions Cert r [11v,1 f:J les tu) Sou1hcente 44, er Of se nded:Stap Arrmric:a Awila 4-4 ;,0 VICINITY MAP DRAWING INDEX SHEET NO. SHEET DESCRIPTION FA0.1 TITLE SHEET FA1.1 FLOOR PLAN - FIRE ALARM SYSTEM FA2.1 FIRE ALARM SYSTEM RISER DIAGRAM AND BATTERY CALCULATIONS INPUTS AND ACTIONS \\J;44,\ � SA OUTPUTS AND CONTROLS �O�Q Og44o ! ,o G �'P cycti OPERATE ALL AREA EVACUATION SIGNALS SOUND LOCAL PIEZO AT FACP INDICATE DEVICE AT FACP SEND ALARM SIGNAL TO C.S. MONITORING SEND TROUBLE SIGNAL TO C.S. MONITORING SEND SUPERVISORY SIGNAL TO C.S. MONITORING SEND WATERFLOW SIGNAL TO C.S. MONITORING ILLUMINATE LED ON DETECTOR PAtO JAM 2) 201C cc TUKWILA FRE DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36" va N 101r.a N01po d ItN0f: F0•20 H 6) • It "d co 13 y LU • 1L 2 Q n 8 1,1 OI:: acti LLiil OO:71.° 00i1-iN ELE.CTRiC Co. Po Box 1 030 M1LTON, vvik 98354 Phlona: (253) 984-1611 Fax: (253) 984-1613 z ADRIAN M. STEIK Senlor Englneering Technician, Level 4 NICET Certifcation Number. 093706 Authorizing Signature: -3-0 SHEET TITLE: DRAWN BY: SAFE Consulting CHECKED BY: Adrian M. Steik PLOT DATE: 12/23/17 PROJECT NUMBER: 17-236 FAOIJ SHEET NUMBER: BACKFLOW PREVENTER TAMPER BACKFLOW PREVENTER TAMPER WET SYSTEM TAMPER SWITCH DRY SYSTEM TAMPER SWITCH WET SYSTEM FLOW SWITCH DRY SYSTEM FLOW SWITCH LOADING DOCK 165 STORAGE 166 TRAINING/ CONFERENCE ROOM 167 STORAGE 164 D SLC1.0005 D SLC1.0004 D SLC1.0003 COLLABORATIVE WORK/LOUNGE 163 BREAKROOM 162 110CD FA-NAC4.011 i FA-NAC4 EOL 5.1K FA-NAC4.010 • 75CD FA-NAC4.006 ::1\ 30CD GAME ROOM 160 WAR ROOM 155 MOTHER'S ROOM 154 MEN'S RIR 152 WOMEN'S R/R 151 OPEN WORKSTATIONS 144 SERVER/ STORAGE 141 PRIVATE OFFICE 140 15CD FA-NAC4.005 MOP 158 FA-NAC4.004 75CD 15CD FA-NAC3.005 ; , CLOSET 157 COPY/PRINT FA-NAC3.004 '• 30CD 147 15CD FA-NAC3.006 15CD ;`� FA-NAC3.007 0 15CD BAR , FA-NAC4.007 173 FA-NAC4t.008 30CD I` N 15CD FA-NAC4.009 FA-NAC5.001 -� 75CD \, FA-NAC5.002 "! it It 0 EOL 5.1K FA-NAC1 : FA-NAC1.008 30CD 75CD FA-NAC1.007 FA-NAC1.006 75CD FA-NAC1.005 :75CD HALLWAY 172 SAMPLING/ WORKROOM 174 15CD ? FA-NAC4.002 A' ADA R/R 151E 15CD FA-NAC3.001 75CD FA-NAC4.001 CLOSET 106 75CD FA-NAC3.002 ' HALLWAY 149 15CD FA-NAC2.002 FA-NAC2.003 75CD OPEN WORKSTATIONS [_...._115 .__.I 15CD 15CD. FA-NAC2.004 FA-NAC2.005 SALES TEAM AREA 177 FA-NAC1.001 75CD 75CD.\ FA-NAC2.001 SLC1.0002 OPEN MEETING 1031 'SLC1.0001 ,1i ADMIN FA-NAC1.004 75CD FA-NAC1.002 30CD 182 FA-NAC5 EOL 5.1K FLOOR PLAN - FIRE ALARM SYSTEM SCALE = 1/8" = 1' 0" 0 4' 8' 12' 16' STORAGE 170 30CD FA-NAC1 '003 0, PRIVATE OFFICE 180 WAR ROOM RECEPTION/ LOBBY 10z.J 110 WAR ROOM 111 ADMIN OFFICE AREA r 139 STAIRS 138 0 15CD FA-NAC3.008 1. 30CD FA-NAC3 EOL 5.1K D. FA-NAC3.010 75CD FA-NAC3.009 OPEN COLLABORATIVE 118 30CD FA-NAC2.006 i OPEN WORKSTATIONS 134 FA-NAC2.007 75CD • LARGE CONFERENCE -- 119 PROJ. MGR AREA 123 SALES TEAM AREA 130 10 ELECTRIC. CO, PG BOX 1 030 M 1 LTO RI , WA 98354 Phone: (253) 984-1611 Fax: (253) 984-1613 DISPLAY/ WORK COUNTER 125 FA-NIAC2.008 30CD\_, FA-NAC2 , EOL 5.1K FA-NAC2.009 PRIVATE OFFICE ADRIAN M. STEIK Senior Engineering Techniclen, Level 4 NICET Certlfcation Number. 093706 Authorizing Signature: DRAWN BY: CHECKED BY: Adrian M. Steik PLAN NORTH 4 PLOT DATE: 12/23/17 PROJECT NUMBER: 17-236 DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36" FA1I1 SHEET NUMBER: Battery Calculations for Panel: FACP Part No:3992717 - IPA -4000, 4064 POINT RELEASING FACP Part No. Qt Description Standby Total Standby Alarm Total Alarm 3992717 Panel Equipment HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD ' 25'-9 0.144A IPA4000 MB 1 IPA4000 MB 0.160A 0.160A 0.200A 0.200A 003 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD Total Panel Stby 0.160A Total Panel Alarm 0.200A 0.042A 005 Peripheral Devices STROBE, M -C, WHITE, WALL, 15CD 26'-0 0.042A 006 S-24WW 6 STROBE, M -C, WHITE, WALL (Notification) 0.000A 0.000A 0.058A 0.348A HS-24WW 4 HORN/STROBE, 2 WIRE, M -C, RED, WALL (Notification) 0.000A 0.000A 0.086A 0.344A HS-24WW 13 HORN/STROBE, 2 WIRE, M -C, RED, WALL (Notification) 0.000A 0.000A 0.144A 1.872A EOL -5.1 5 EOL 5.1 K (Notification) 0.000A 0.000A 0.000A 0.000A S-24WW 14 STROBE, M -C, WHITE, WALL (Notification) 0.000A 0.000A 0.042A 0.588A HS-24WW 1 HORN/STROBE, 2 WIRE, M -C, RED, WALL (Notification) 0.000A 0.000A 0.189A 0.189A S-24WR 1 STROBE, M -C, RED, WALL (Notification) 0.000A 0.000A 0.116A 0.116A MBA -624 1 61N VIBRATING FIRE BELL 24V RED (Notification) 0.000A 0.000A 0.060A 0.060A PSA 1 PHOTO SMOKE DETECTOR (Signaling line) 0.000A 0.000A 0.001A 0.001A APS -SA 1 PULL STATION, SINGLE ACTION, ADDRESSABLE Si.nalin. line 0.000A 0.000A 0.000A 0.000A DCM-4 3 DUAL INPUT CONTACT MODULE (Signaling line) 0.000A 0.000A 0.001A 0.003A Total Peripheral Stby 0.001A Total Periph Alarm 3.522A Total Standby Amps 0.161A Total Alarm Arno__ 3.722A Standby time: 24 Hrs 3.856Ah Alarm time: 5 Min 0.31Ah Battery requirement: 4.166Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 4.999Ah Circuit Calculations Panel: FACP Card: 00 Circuit:FA-NAC1 Device 001 002 003 Part No 3992717 HS -24W W HS-24WW S-24WW CircuitName: FA-NAC1 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 3.000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Minimum operating voltage: 16V Appliance Desc Panel HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD HORN/STROBE, 2 WIRE, M -C, RED, WALL, 30CD STROBE, M -C, WHITE, WALL, 30CD 004 005 006 007 008 008 HS-24WW HS -24W W HS -24W W HS-24WW HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD HORN/STROBE, 2 WIRE, M -C, RED, WALL, 30CD Distance Current Volt ge Voltage Drop 20.4V 25'-0 0.144A 20.254V (0.146V) 22'-6 0.086A 20.14V (0.114V) 29'-7 14'-1 0.058A 0.144A 20.008V 19.951V 55-1 35'-11 0.144A 0.144A 32'-8 0.144A 12'-2 0.086A EOL -5.1 EOL 5.1K 2'-8 229'-8 0.000A 19.776V 19.693V 19.647V 19.64V 19.64V (0.133V) (0.057V)_ (0.175V) (0_083V) (0.047V) (0.006V) (0V) 0.950A Total Current: 0.950A (Total VDrop Percent:3.72%) Total Voltage Drop : 0.76V Circuit Calculations Panel: FACP Card: 00 Circuit:FA-NAC2 CircuitName: FA-NAC2 Circuit Type: Notification Terminal Voltage: 20.4V:DC Cable: 14/2 SOL JKT FPLR 1M RL RED Calculations based on Running Tota Design Criteria: Ambient temperature: 167°F Minimum Amperage: #14 Length. operat�in Distance 3.000A voltage: 16V Current Voltage 20.4V Voltage Drop Device Part No Appliance Desc Panel 3992717 001 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD ' 25'-9 0.144A 20.283V 20.164V 20.1V 20.031V 19.974V 19.958V (0.117V) (0.119V) (0.064V) (0.069V) (0.057V) (0.016V) (0.065V) (0.019V) (0.011V) (OV) 002 S-24WW STROBE, M -C, WHITE, WALL, 15CD 32'-7 19'-1 0.042A 0.144A 003 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 004 S-24WW STROBE, M -C, WHITE, WALL, 15CD 27'-8 0.042A 005 S-24WW STROBE, M -C, WHITE, WALL, 15CD 26'-0 0.042A 006 S-24WW STROBE, M -C, WHITE, WALL, 30CD 8'-3 0.058A 007 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 40'-9 27'-5 0.144A 0.058A 0.058A 19.893V 19.873V 19.863V 008 S-24WW STROBE, M -C, WHITE, WALL, 30CD 009 S-24WW STROBE, M -C, WHITE, WALL, 30CD 30'-5 009 EOL -5.1 EOL 5.1K 2'-10 240'-9 0.000A 0.732A 19.863V 2'-6 0.000A 19.798V (0V) Tota Current: 0.732A (Total VDrop Percent:2.63%) Total Voltage Drop : 0.537V Circuit Calculations Panel: FACP Card: 00 Circuit:FA-NAC3 CircuitName: FA-NAC3 Circuit Type: Notification Terminal Voltage: 20.4V Cable: 14/2 SOL JKT FPLR 1M RL RED Calculations based on Running Tota Design Criteria: Ambient temperature: 167°F Minimum DC Amperage: #14 Length. operating Distance 3.000A voltage: 16V Current Voltage 20.4V Voltage Drop Device Part No Appliance Desc Panel 3992717 001 S-24WW STROBE, M -C, WHITE, WALL, 15CD 61'-2 0.042A 0.144A 20.144V 20.077V (11256V) (0.067V) 002 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 16'-8 003 S-24WW STROBE, M -C, WHITE, WALL, 15CD 6'-0 20'-4 0.042A 0.086A 0.042A 0.042A 0.042A 20.058V 20.002V 19.989V 19.914V 19.867V (0.018V) (0.056V) (0.014V) (0.075V) (0.047V) 004 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 30CD 005 S-24WW S-24WW STROBE, M -C, WHITE, WALL, 15CD STROBE, M -C, WHITE, WALL, 15CD 5'-7 36'-10 27'-3 006 007 S-24WW STROBE, M -C, WHITE, WALL, 15CD 008 S-24WW STROBE, M -C, WHITE, WALL, 15CD 25'-6 0.042A 19.828V (0.039V) 009 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 13'-10 34'-10 0.144A 0.058A 19.811V 19.798V (0.017V) (0.012V) 010 S-24WW STROBE, M -C, WHITE, WALL, 30CD 010 EOL -5.1 EOL 5.1K 2'-6 0.000A 19.798V (0V) 0.189A 011 EOL -5.1 250'-6 0.684A 0.000A 0.975A 19.114V (Total VDrop Tota Current: 0.684A Percent:2.95%) Total Voltage Drop : 0.602V FIRE ALARM BATTERY & VOLTAGE DROP CALCULATIONS 0,11, SCALE = NOT TO SCALE EOL 5.1K FA-NAC4 110CD FA-NAC4.011 EOL 5.1K cx FA-NAC3 75C0 FA-NAC4•010 30CD FA-NAC3.010 EOL 5.1K a.' FA-NAC2 Ck FIRE ALARM RISER DIAGRAM SCALE = NOT TO SCALE 15CD FA-NAC4.009 75CD FA-NAC3009 30CD FA-NAC2.009 EOL 5.1K FA-NAC1 Circuit Calculations Panel: FACP Card: 00 Circuit:FA-NAC4 CircuitName: FA-NAC4 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Minimum o•eratin• 3.000A voltage: 16V Current Voltage 20.4V Voltage Drop Device Part No Desc Distance 3992717 _Appliance Panel 001 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 82'-3 0.144A 0.042A 0.042A 19.909V 19.792V 19.724V 0.491VZ 0.117V) 0.068V) 0.142V) 0.074V) 0.107V) (0.07V1 Jp.051V) (0.023V) (0.133V) (0.01V) 002 S-24WW STROBE, M -C, WHITE, WALL, 15CD 23'-4. 003 S-24WW STROBE, M -C, WHITE, WALL, 15CD 13'-7 004 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 30'-6 0.144A 0.042A 19.582V 19.508V 005 S-24WW STROBE, M -C, WHITE, WALL, 15CD 19'-10 006 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 30CD 31'-3 0.086A 0.042A 19.401V 19.331V 19.28V 19.257V 19.124V 19.114V 007 S-24WW STROBE, M -C, WHITE, WALL, 15CD 23'-11 008 S-24WW STROBE, M -C, WHITE, WALL, 30CD 18'-11 0.058A 009 S-24WW STROBE, M -C, WHITE, WALL, 15CD 9'-11 65'-1 0.042A 0.144A 010 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 011 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 110CD 9'-3 0.189A 011 EOL -5.1 EOL 5.1K 2'-0 329'-10 0.000A 0.975A 19.114V a) Tota Current: 0.975A (Total VDrop Percent:6.30%) Total Voltage Drop : 1.286V Circuit Calculations Panel: FACP Card: 00 Circuit:FA-NAC5 CircuitName: FA-NAC5 Circuit Type: Notification Terminal Voltage: 20.4V:DC Cable: 14/2 SOL JKT FPLR 1 M RL RED Calculations based on Running Tota Design Criteria: Ambient temperature: 167°F Minimum Amperage: #14 Length. operating Distance 3.000A voltage: 16V Current Voltage 20.4V Voltage Drop Device Part No Appliance Desc 3992717 Panel 001 MBA -624 6IN VIBRATING FIRE BELL 24V RED 146'-2 0.060A 20.242V (0.158V) 002 S-24WR STROBE, M -C, RED, WALL, 75CD 1'-8 1'-8 0.116A 0.000A 20.241V 20.241V (0.001V) (VI DCM-4 EOL -5.1 EOL 5.1K 0.000A 0004 DCM-4 149'-6 0.176A 0.000A (Total VDrop Tota Current: 0.176A Percent:0.78%) Total Voltage Drop : 0.159V Circuit Calculations Panel: FACP Card: 00 Circuit:SLC1 CircuitName: SLC1 Circuit Type: Signaling Zine/Potter - SLC Terminal Voltage: Cable: 16/2 SOL JKT FPL 1M RL RED Calculations based on Running Tota Design Criteria: Ambient temperature: 167°F Minimum 20.2V:DC #16 Length. operating Distance Amperage: voltage: 16V Current 1.000A Voltage 20.2V Voltage Drop Device Part No Appliance Desc 3992717 Panel 0001 APS -SA PULL STATION, SINGLE ACTION, ADDRESSABLE 1'-8 0.000A 20.2V (0V) (0V) (OV) 0002 PSA PHOTO SMOKE DETECTOR 4'-8 0.000A 20.2V 20.2V 0003 DCM-4 DUAL INPUT CONTACT MODULE 184'-2 0.000A 0004 DCM-4 DUAL INPUT CONTACT MODULE 2'-3 0.000A 20.2V (OV) 0005 DCM-4 DUAL INPUT CONTACT MODULE 2'-4 0.000A 0.001A 20.2V (0V) 195'-1 Total Current: 0.001A (Total VDrop Percent:0.00%) Total Volta • e Dro • : OV 30CD FA-NAC4.008 15CD FA-NAC3.008 30CD FA-NAC2.008 30CD FA•NAC i•008 15CD FA-NAC4.007 15CD FA-NAC3.007 7500 FA-NAC2.007 7500 FA-NAC1.007 30CD FA-NAC4.006 15CD FA-NAC3.006 30CD 15CD FA-NAC4.005 15CD FA-NAC3.005 15CD FA-NAC2.006 FA-NAC2.005 75CD FA-NAC1.006 75CD FA-NAC1.005 75CD FA-NAC4✓004 30CD FA-NAC3.004 15CD FA-NAC2.004 75CD FA-NAC1.004 EOL 5.1K ca ... FA-NAC5 15CD FA-NAC4.003 15CD FA-NAC3.003 7500 FA-NAC2.003 30CD FA-NAC1.003 75CD FA-NAC5.002 15CD FA-NAC4.002 75CD FA-NAC3:002 15CD FA-NAC2.002 30CD FA-NAC1.002 FA-NAC5.001 7500 FA-NAC4701 15CD • FA-NAC3.001 7500 FA-NAC2001 7500 FA-NACI•001 FACP F SLC1.0001 SLC1.0002 SLC1 0003 D SLC1.0004 SLC1.0005 Level 0 DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36" N ri NUlm N`0 1 +" L1J 0� 40 0 H `� • o • Qoo W • .LLE Q I - °u • (n 0 - 2Q N acHo -c IL NIC Oit.c CO 0 0 13 01�• S 0 3 T-1 vi O. 3 ELECTRIC. CO, PO BOK -1 030 IV11 LTO N , WA 98354 Phone: (253) 984-1611 Fax: (253) 984-1613 ADRIAN M. STEIK Senior Engineering Technician, Level 4 NICET Certlrcetlon Number. 0937060 3 Authorizing Signature: (i.-- "` _ DRAWN BY: CHECKED BY: PLOT DATE: PROJECT NUMBER: FA2.1 SHEET NUMBER: 15455 53RD AVE S ASSOCIATED PERMITS D19-0275 D17-0199 18-F-030 18-S-041 40W1,44 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 15455 53rd Ave S Tenant Name: Seatac Lighting Property Owner's Name: Seatac Liqhtinq King Co. Assessor's Tax No.: 115720-0044 Suite Number: Floor: New Tenant? © - Yes ❑ - No Mailing Address: 15455 Tukwila Wa 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Kevin Ullrich Day Telephone: 253-569-6917 Company Name: Abacus Electric Co Mailing Address: 3401 12th St E Fife Wa 98424 kevin@abacuselectricllc com City State Zip . E-mail Address: Fax Number:2 5 3— 9 8 4 —1613 NICET III number: 093706 Contractor's City of Tukwila Business License number: BUS -0993200 Total number of new/relocated devices or sprinkler heads: (41) tot al new devices Valuation of Project (contractor's bid price): $ 15,000.00 Scope of Work (please provide detailed information): Installation of all new Fire Alarm System for new tenant layout PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: UTHORIZED AGENT: Print Name: Kevin Ullrich Plan Permit App.doc Date: 1/22/2018 Day Telephone: 253-569-6917 8/22/14 TFD FP Form 8 1 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Permit No.: Date: Reviewer: Seatac Lighting 15455 53rd Ave. S 18-S-041 March 6, 2018 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. A • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Z,19- PIERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:. ----N zei/LA, Type of Inspection: Hood & Duct: Address: Suite #: / "sr 6.' ''2$ Contact Person: Special Instructions: Phone No.: IQD Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: /'1. -/ -64".€ lA ,i" o Pa ht s ti4 - ori �F A6t..I•125g C - /Veer' Rkity bemx , cd.g-c4-%\,z+ K-02- 114.10 r - ).- CAI --e # �iv Li,_ rt,liN► Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:` 4 Date: ..0/azo Hrs.: / d $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project��G ( c1411,”Type of Inspection: F(1\1/1-1. Address: Suite #: /4 s-'�Ait. Contact Person: Special Instructions: Phone No.: ak#A;proved per applicable codes. I I Corrections required prior to approval. COMMENTS: p.zta- �l✓t�t,� a r(e.‘ ri,art.-- 01Z e(23 e--&f/P 7 Needs Shift Inspection: 7 Sprinklers: fIA Fire Alarm: Ai Hood & Duct: -FS Monitor: ► 1z -river; ,L( j✓ ' Pre -Fire: Permits: I CrC�141-- Occupancy Type: 1g Inspector: I fIA Date: 21, 2Jl) Hrs.: ' `7 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit _p»^ 0 iic PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: /'' #rci.e's r Type of Inspection: /c;hL;:i Address: Suite #: / SYS3" 53 Ave S, Contact Peri6i / Cer_off Av..-,47,e_ Special Instructions: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: / /'' #rci.e's Fire Alarm: Hood & Duct: Monitor: Pre -Fire: #:-‘4.01.,_ ryii, — R.o.er,,v„,141 / Cer_off Av..-,47,e_ frirole-Yt4/ -- / e( 3 — V .0 Aver -- 6,e -i -r .41. C ' . ./ 66✓14. Yl Ny4e1 i — 72G,,c /Jag 6~Qa-f` 1 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: A 5-7 Date: 7/./0,//g Hrs.: r• U ,r„", . / / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F,D. Form F.P. 113 ✓/ INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:-, t� Type of Inspection:1c,,/„..5 ,/� Address: Suite #: i c3 /fro_ Contact P n: Special Instructions: , Phone No.: Pre -Fire: I Approved per applicable codes. nCorrections required prior to approval. COMMENTS: Date: Sprinklers: r.,, Fire Alarm: or 0 //4.1)414.,/ /vim,ire iivt Monitor: , — -04. Pre -Fire: .s./„, iv eftve_i .-- A/ ti Ail/ 04 vim- 6 ---- r. -,..414e- Adetzav,t. , 4-).4,( j A f/ -- eioAr, trY-- 1//_S" I S Needs Shift Inspection: Date: Sprinklers: r.,, Fire Alarm: or 0 Hood & Duct: Monitor: - - Ai 0.4 it, Pre -Fire: Permits: Th. "1 S -Z- 2Y q o Occupancy Type: Inspector:?z AI 6:3 Date: 7// p ii t Hrs.: / .. 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 CORRECTION NOTICE/REINSPECTION FEE Inspector: Permit number: TUKWILA FIRE MARSHAL'S OFFICE Office: 206-575-4407 Fax: 206-575-4439 Email: Fire Marshal@tukwilawa.gov Business Name: / Type of Inspection. 400 f Location Address:/ !, 63 AVIS Date : 7/6k / / A Contact Person : X ci.t.,.447 , Phone No.• zs,-.s-7.3as ACTION REQUIRED l'Ali' cAt / ea° — ---- A&wit. Lott_ ',0,,,,k(ed- p,„,t, -,zo c -,-,,414w Ai/nt ci.t.,.447 ta fir/ At 4. -ft u.vai.- nii Pco-vi e6 36 .i afr•-,./ee A,,g,i. 40 Mete flC ni/L/(4\1\12 1 _ CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY : FAILURE TO COMPLY MAY RESULT IN THE ISSUANCE OF A CRIMINAL CITATION/TICKET. Billin ailing Address : Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Reinsp Fee2.doc Revised 6/17/14 T.F.D. Form F.P. 100 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 5e64_,FacHi S Type of Inspection Address: Suite #: '4-S Fire Alarm: 4\h2 �, Contact Person: Special Ins ructions: Monitor: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: �.V. 5 Hrs.: Fire Alarm: kta.a5 ak_ ID cq I Monitor: Pre -Fire: 'EzN.. s/ Permits: re -D, 477--)e 7 ..c: I? 4.r -A --e— I 7 5w'p 19-7/t.-- ()rt ,1 -e-& d S 0-1+i--- w/ /vim -3 0_ A /P661- 17£G✓ alit C- ig Needs Shift Inspection: Sprinklers: �.V. 5 Hrs.: Fire Alarm: kta.a5 Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: g Inspector: 1 5-`4 Date: (o/ 2.q( r Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 A INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit DV7 _D\c / S --s -041 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Type of Inspection: .-.a- ,o 9--IA.r-1.. La C-uv.e. r Project --LF` LIgt411,13 Address: Suite #: / 51.55 -53 °114N..S Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: yslco RtriV". � Q oo�ZQ5fSr�,", Occupancy Type: 7(L (43.70 Q 705 Ps1 0E-6 Cromtic Lia 1 r, 134,ketibrvks or.L. -xl-k_`"'n 1 cA. ov, - . r A.. S{J.r:- L..,. t.t< °i,S 1 t,rtiw Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ti7-sf‘&V Date: ( p-1 (g Hrs.: Z, $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 TUKWILA FIRE MARSHAL'S OFFICE '440 Phone: 206-575-4407 • Email: FireMarshal dtukwilawa.gov CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date 6Ja5I it Permit # t " F - () 3) Property Address 15 4 55 5 3 ra Ave. S Suite # City TUKWILA Zip Code qg t gg Name of Facility Tot W3 Occupied as c2,r421:wc\n\;v- Owner or Representative Phone # Installing Company A1a64...4,L6 Ehcc�tticr Installing Contractor's Address 3401 I2++' SA- City +Cit}- Phone # ;63- 9g LI -IC 11 Installer's Name (PRINT) bcv;c1 CL61.41(c.rel License and/or Certificate L L 01 C,1-iOlCl1 5330Q General Contractor Co\iog Coe• -s Electrical Contractor A10,...cL..4EL c k_ FACP Equipment Manufacturer ?o tkr- Model # Ipts,-"(oo° This system has been installed. pre-testid and operates in accordance with the standards listed below and was inspected by k CLe vuWQ� On (date) 7/10/N and includes the devices listed on back. Circle all that apply: ✓/ NFPA 72, Chapter 1 2 4 5 6 7 and/or IFC SEC 907 ✓ NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions LManufacturer's Instructions / Other (specify) ✓ Tukwila City Ordinance Numbers 2050. 2051 UL Central .tion MIonit .ut , c-4 _ .vste is monitored b� Atc.rw, Cxx s wAC.. SIGNE6,LJ lam_ Date 7—iv-l$ Syst�Vrmware: ?.,NKr F: rt.- .. v..\ ero ,r^ry r' Installed version (4.03.0 Checksum Date 6 1/ (i? Initial program Installation Date Revisions and Reasons 7ftotl% Programmed by -Do,34 CL,ik„ , EQUIPMENT INSTALLED AND TESTED: Control Panel 4 of Manual Station of S Smoke Detectors A_ of —�-- Heat Detectors of Duct Detectors of I� tg A/V Devices eKofit Audio Devices ofJ Visual Devices 2_ of Auto Door Release of Trouble Indictors of Batteries Readings Battery a G . g Generator of HVAC Controls of Fire Alarm Dialer of Monitored by Make/Model POAAfS 000 Make/Model ?Alms ?kb 100 - ?SSA Make/Model Poi -kr btz)- ?t Make/Model Make/Model Make/Model �• NS-wki / CNS Make/Model l'eWcr- (1,,k A- 09 Intl Make/Model ?ok&s S— 1y WW /.61116 C.S -,;(4 wtA) Make/Model Make/Model Full Load a4. Make/Model Make/Model Make/Model Charge 'I.31 V Annunciator of Make/Model Sprinkler System. (Fire Alarm connections only) Water Flow Sw. Valve Tamper Sw. PIV Elec. Alarm Bell 1 of ( of of of Make/Model i'. cs PS to -a. Make/Model # F Q 36 Make/Model Make/Model Automatic time Delay of Water Flow Alarm seconds. None Installed Do you eet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes No Test of alarm System on emergency power, satisfactory? Yes / No Test Witnessed by cS Ls4.; . C- ��4►{1 Title rel) Date 7—/p -/ Comments: Fire Alarm Certificate.doc Revised: 6117/I4 TFD FP Form 110 4 , Ir It EXISTING PIV TO REMAIN IN ITS CURRENT LOCATION REMOVE THE EXISTING UNDERGROUND DETECTOR CHECK EXISTING 8' UNDERGROUND WATER MAIN 53RD AVE. S Io ' REMOVE THE EXISTING REMOTE FDC EXISTING FIRE SPRINKLER RISER SEATAC LIGHTING L_J 53RD AVE. S HIGHWAY 581 EXISTING FIRE SPRINKLER RISER LOCATION NEW MOUNTED STORZ FDC SITE PLAN SCALE: NT5 SITE PLAN SCALE: NTS HANGER SPACING CHAR T IXIE 8221 MAXIM MACE EVISEN HAWN -111) 92E - 3/4 1 1-1/4 1-1/22 f7 2-1/2 3 4 6 S7 Z L' N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 DREADED N/A 120 120 120 120 — 1 -bar �,' SKYLIGHT \��" N N 1• o 5— — -©- — — 12-0 0 TYP. -5 - �- _0 J2 — o fl F - I. a la 1-61 l 120 120 N/A N/A 80 80 10 0 10 0 12 0 12 0 15 0 15 wvrRzat 12-0 0 4 WAVEROM SRSIUR 8) 1,�� • • • • • • ME OBE CR ZIP ORE MEOW ADD RE OEM' MI J8' RP Y SEAM NAV 48"RDg/)/."'- AMERMN8C RD 11y a LA WEED RE P3 DE MVP= WM EBBW LOST Mtn tI FE MUCH WSW marsrma ER SEN AMER GA rt WC RPM ME" POSEN BE DEE LtL21 MATER ACD MS I. f'IFE9S ME OF REV H E'SE MAIL Or ND LlhRI AM) 46 3, 8AND 8. 1%1'AtTLWRO GENERAL NOTES SYSTEM COMPONENTS 01. AUTOMATIC SPRINKLERS CHARACTERISTICS SHALL BE QUICK RESPONSE SEE SPRINKLER LEGEND FOR SPRINKLER PROPERTIES 02. PIPING FOR BRANCH ONES TO BE EXISTING BLACK SCHEDULE 40 03. PIPING FOR CROSSMAIN ONES TO BE: DOSING BLACK SCHEDULE 40 04. JOINING OF BRANCH ONES PIPING TO UTILIZE: EXISITNG BLACK CAST IRON 05. JOINING OF CROSSMAINS TO UTILIZE EXISTING GROOVED MECHANICAL FITTINGS & COUPUNGS 06. HANGERS SHALL UTILIZE: SAMMY WOOD SCREW. ALL THREAD ROD. & NOMINAL SIZED RING SEE HANGER DETAIL(S) THIS .SHEET 07. CONTROL VALVE(S) TO BE: EXISTING PIV 08. SPRINKLER SYSTEM ALARM SIGNALING DEVICE TO BE: EXISTING WATER MOTOR GONG SYSTEM REQUIREMENTS 01. SYSTEM DESIGN CRITERIA FOR SPRINKLER SYSTEM: EXISTING ORDINARY HAZARD PIPE SCHEDULE SYSTEM SYSTEM EXCLUSIONS 01. WIRING OF ELECTRICAL ALARM SIGNALING DEVICES 02. PAINTING OF NEWLY INSTALLED PIPE AND COMPONENTS. 03. PATCHING AND/OR REPAIRING CEIUNG OR WALLS. 04. ADEQUATE HEAT ABOVE CEIUNGS. 05. MODIFICATIONS TO THE EXISTING SEISMIC BRACING. OPEN WORKSTATIONS eF2 144 OFz OPEN WORKSTATIONS BUILDING INFORMATION: PARCEL #: 1157200044 OCCUPANCY GROUP: B TOTAL SQ. FT.: 20,524 BUILDING OWNER'S INFORMATION: JOHN BORELLI SEA -TAC LIGHTING AND CONTROLS 4439 SOUTH 134th PI BUILDING E TUKWILA, WA 98168 (206) 575-6865 SCOPE OF WORK: • ADD AND RELOCATE SPRINKLERS HEADS TO ACCOMMODATE THE NEW WALLS AND CEILINGS. • • REPLACE THE EXISTING EXPOSED SPRINKLER HEADS WITH NEW QUICK RESPONSE SPRINKLER HEADS. • INSTALL A NEW DERINGER 30 (X) BACKFLOW PREVENTER ON THE EXISTING RISER. • • INSTALL A NEW WALL MOUNTED 5" STORZ FDC. • REMOVE THE EXISTING REMOTE FDC AND DETECTOR CHECK. • NO WORK IS TO BE DONE TO THE EXISTING DRY SYSTEM THAT FEEDS THE FRONT AND BACK CANOPIES. SPRINKLER LEGEND N = REPLACE THE EXISTING HEAD WITH QR R = NEW QR RELOCATED SPRINKLER HEAD A = NEW QR ADDED SPRINKLER HEAD P = PLUGGED SPRINKLER HEAD — — — — — — = EXISTING PIPE = NEW PIPE DETAIL A 5CALE: NT5 4 0 Without Comments As Noted ,n Red .71. -Per The Attached Letter Thes-rp1ans have been reviewed by The Tukwila Fire ?re"en rtion Bureau forconforrnarce with curr standards. Acceptance is subject- to errors a o;nissL)ns which :Oi authorize violations of adopted ,':mdarrs and.7Pporcrr nces. The responsibility for the „1egLede cy of s'q t }?' ;:s totally/ .with the designer. deletion- . ; -visions to these drawings after -r!s date will '•:;ld tl-)!z_ acceptance and will require a r e zubmlttai of r v sed irawings for subsequent approval. '4 F incl acceptance is subject to Held test and ll The Tukwila Fire Prevention Bureau. Date:By: ice`^ S � 1 N 5 — ri 12-0 F2 1•431-7.1 I-8.1 CLOSET 106 N 1' TYP. 16-73€ lin .- .-"o OPE! -� MEETII #N ' • .' 1'4 k 103 2-1 1-1 , — 1 -bar �,' SKYLIGHT \��" N N 1• o 5— — -©- — — 12-0 0 TYP. -5 - �- _0 J2 — o fl F - I. a la 1-61 l J 42-1 RfR00M TO WET SYSTEM ELEV. I I' -G" 7 / / / / / / . EXISTING WATER MOTOR GONG (N) 8x4' MACH T 4' GROOVED CHEC VALVE TO FRONT AND REAR CANOPI 4' DRAIN 90 TH 1/2' BALL DRIP EXISTING 4' DRY PIPE VALVE EXISTING VALV8' ALARM E / / / / / / / / / / SPRINKLER BRANCHUNE. 1' PIPE WITH 1' CI SCR 90 MADE -ON (UST BY UNE -INSTALL AT ROUGH -IN). " 054Y VALVE N N STORAGE 1' ARMOVER COJ PIPE ' 1' CI SCR 90 10 DROP WITH 1x1¢ REDL..ER MADE -ON, TO BE COJ 4'90 4.90 EXISTING COMPRESSOR SHOWN FOR ILWSTATION PURPOSES ONLY NEW 8' DERINGER 30 00 DCDA-II • (N) FLGx▪ GRV PCS REMOVE EXISTING 8" SPOOL PCE. T1JKWILA FIRE NPARTMMT eye se call 205-575-4407 and this Alpe Permit NO. 'LJ exact address for shut Or festoratlon approves + WATERFLOW DETECTOR JFFICE ©moo - 180 I A FIRE SPRINKLER PLAN fl? tI f ,._ ... _ a..;1111111111111.111.1111111111 SCALE 1/8=1'-0' FIRE SPRINKLER PLAN SCALE: NT5 0 (N) FLGxGRV PC5 EXISITNG 8' DUCTILE IRON. •IG's'dIKNOTON STATE CIEWWICATB OF coswarsocy $YSTEDIS Michael Maguire 1440-0791-C Level 3 Archer. nstruction, Inc. ARCHE*21 R EXISTING RISER ROOM/SECTION VIEW SCALE: NTS (E) GRADE REVISIONS DATE DESCRIPTION BY A HANGERS BEAM CLAMP W/ RETAINING STRAP 1-24-18 PER CARL ANDERSON REVIEW MM B SIDE BEAM BRACKET AREA NUMBER CODE HYDRAULIC DESIGN INFORMATION [HAZARD SYSTEM TYPE . C EYE SOCKET D NUT & PLATE WASHER E KWIK BOLT REMOTE AREA SQ FT. DENSITY GPM/SQ. FT. INSIDE HOSE ALLOWANCE OUTSIDE HOSE ALLOWANCE AREA PER SPRINKLER F HDI -P G SAMMY SIDEWINDER TOTAL SYSTEM REQUIREMENTS: H SAMMY SUPERSCREW HYDRAULIC DESIGN INFORMATION J COACH SCREW ROD K CEILING FLANGE AREA NUMBER CODE I HAZARD SYSTEM TYPE L U -HOOK M N SHORT STRAP WALL BRACKET REMOTE AREA SQ. Fr. DENSITY GPM/SQ. FT. INSIDE.HOSE ALLOWANCE OUTSIDE HOSE ALLOWANCE AREA PER SPRINKLER P TRAPEZE TOTAL SYSTEM REQUIREMENTS: ABBREVIATIONS WATERFLOW INFORMATION AFF BTS BOD BOJ BOP BOT CTS FO IFOW NAS OTS UNO ABOVE FINISHED FLOOR STATIC BOTTOM TO STRUCTURE BOTTOM OF DECK RESIDUAL BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL NO AUTO. SPRINKLERS OPEN TO STRUCTURE UNLESS NOTED OTHERWISE RIGID COUPLING FLEXIBLE COUPLING XX PSI XX PSI GPM FLOWING XXXX GPM DATE & TIME PER: XX/XX/XXXX SPRINKLER SYMBOLS RC SYM MAKE MODEL SIN# TYPE FINISH THREAD ORIFICETEMP CANOQTY C) • GLOBE GL6601 PEND CHROME 1/2 1/2' ; " CEROPY LOCATION: NOTES: MEI TOTAL PROJECT SPRINKLERS = TOTAL SPRINKLERS THIS SHEET 209 HE • CONSTRUCTION, INC SEATAC LIGHTING PIPING PLAN FIRE SPRINKLER DIVISION 7855 5 206TH STREET, KENT, WA 98032 PHONE 253-872-7222 FAX 253-872-7277 15455 53rd Ave. S. TUKWILA, WA. 98188 PERMIT NO: - JOB NO: 817-143 AUTHORITY: CITY OF TUKWILA PAID FE3 23 2CWW TUKWILA FIRE 30v DESIGNER: MIKE SCALE: NOTED DATE: 2-9-18 REVISED 2/9/18 PLOTTED / / FP 1 OF 1 • Without Comments YE' As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which Ccs not authorize Violations of adopted standards - . a Lir dt<:ances, The responsibility for the adequacy of desiral`, r.$1' totally with the designer. Additions, deletions o < visions to these drawings after this date will void tr-ii;- ,;_,.eptance and will require a resubmittal r,f t-,�vi=, ..) .r,,vings for subsequent approval. Final acceptance 'Pi. suojecr to field test and inspection by The Tukwila Firs: Prevention i Bureau. Date: D- " L g E;y: Chs�,n w�ghvwi poi 3.-1-c.4'i.oh.3 or -i- J e41C-Ize exv)-s. :1:v1.$44 loreakt. 1'4.1dile z.tu‘»p ol, darA 6'eaktr, -X hill Q�a✓C,� ,r W P be 07.54,0 c. caeo,S-c'r>..e , 4cc-eSJ t TUKW' l A FRE " 'SEP ^ RTMEN cafi 206-5154107 aria give, this F i3'e Permit No. c�-F -030 ':Xiexact address for shut S loVVn or restoration appr,ovale FIRE ILJFtI I_ 71- oa 88 Fire Alarm Symbol Legend SYMBOL DEVICE MOUNTING DETAIL PART NUMBER QUANTITY FACP IPA -4000, 4064 POINT RELEASING FACP IPA -4000 // ///, ROOF DECK // / /�,% / 7//// \ / � / / /////1/ s: PHOTO SMOKE DETECTOR -►'T' '!'iv, MOUNT TO 1 F ` �. PAD100-PSSA 1 z DUAL INPUT CONTACT MODULE PAD100-DIM STRUCTURE / i BASE .w.� HEAD 3 -BOX // ABOVE CEILING DEVICE SUPPORT BRACKET \' 110CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 1 .\ 30CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 4 75CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 13 30CD STROBE, M -C, WHITE, WALL • S-24WW 6 15CD STROBE, M -C, WHITE, WALL S-24WW 14 PLASTER RING STROBE, M -C, RED, WALL CEILING 1 POTTER ELECTRIC SIGNAL �'*K -� MBA -624 1 BASE HEAD SMOKE OR HEAT DETECTOR EOL 5.1K EOL -5.1 HORN/STROBE POTTER ELECTRIC SIGNAL EOL -5.1 SEND SUPERVISORY SIGNAL TO C.S. MONITORING SEND WATERFLOW SIGNAL TO C.S. MONITORING \\ ILLUMINATE LED ON DETECTOR MANUAL PULL STATION BACK MOUNTED WALL /, / BOX TO FRAMING Lwr �. FIRE ALARM ® 80" 48" ,_,- ,_^ j,.^ 1 • • Without Comments YE' As Noted in Red o Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which Ccs not authorize Violations of adopted standards - . a Lir dt<:ances, The responsibility for the adequacy of desiral`, r.$1' totally with the designer. Additions, deletions o < visions to these drawings after this date will void tr-ii;- ,;_,.eptance and will require a resubmittal r,f t-,�vi=, ..) .r,,vings for subsequent approval. Final acceptance 'Pi. suojecr to field test and inspection by The Tukwila Firs: Prevention i Bureau. Date: D- " L g E;y: Chs�,n w�ghvwi poi 3.-1-c.4'i.oh.3 or -i- J e41C-Ize exv)-s. :1:v1.$44 loreakt. 1'4.1dile z.tu‘»p ol, darA 6'eaktr, -X hill Q�a✓C,� ,r W P be 07.54,0 c. caeo,S-c'r>..e , 4cc-eSJ t TUKW' l A FRE " 'SEP ^ RTMEN cafi 206-5154107 aria give, this F i3'e Permit No. c�-F -030 ':Xiexact address for shut S loVVn or restoration appr,ovale FIRE ILJFtI I_ 71- oa 88 Fire Alarm Symbol Legend SYMBOL DESCRIPTION PART NUMBER QUANTITY FACP IPA -4000, 4064 POINT RELEASING FACP IPA -4000 1 s: PHOTO SMOKE DETECTOR PAD100-PD 1 F ` PULL STATION, SINGLE ACTION, ADDRESSABLE PAD100-PSSA 1 - 1 D DUAL INPUT CONTACT MODULE PAD100-DIM 3 \' 110CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 1 .\ 30CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 4 75CD HORN/STROBE, 2 WIRE, M -C, WHITE, WALL HS-24WW 13 30CD STROBE, M -C, WHITE, WALL • S-24WW 6 15CD STROBE, M -C, WHITE, WALL S-24WW 14 75CD STROBE, M -C, RED, WALL S-24WR 1 POTTER ELECTRIC SIGNAL 6IN VIBRATING FIRE BELL 24V RED MBA -624 1 , EOL R° EOL 5.1K EOL 5.1K EOL -5.1 5 FIRE ALARM CABLING LEGEND CODE CABLE LINETYE CIRCUIT TYPE MANUFACTURER PART NO. CABLE TYPE A IPA -4000, 4064 POINT RELEASING FACP INITIATING DEVICE CIRCUIT BELDEN 5320UL 18/2 FPLR B IPA4000_MB NOTIFICATION APPLIANCE CIRCUIT BELDEN 5120UL 14/2 FPLR C • AUXILIARY DEVICE CIRCUIT BELDEN 5120UL 14/2 FPLR D PAD100-6B REMOTE ANNUNCIATOR CIRCUIT BELDEN f 5320UL, 5120UL 18/2 FPLR, 14/2 FPLR 3 Bill of Material Qty. Description Manufacturer Part No. 1 Panel: FACP 1 IPA -4000, 4064 POINT RELEASING FACP POTTER ELECTRIC SIGNAL IPA -4000 1 IPA4000_MB POTTER ELECTRIC SIGNAL IPA4000_MB 1 PHOTO SMOKE DETECTOR POTTER ELECTRIC SIGNAL PAD100-PD 1 6" ADDRESSABLE BASE POTTER ELECTRIC SIGNAL PAD100-6B 1 PULL STATION, SINGLE ACTION, ADDRESSABLE POTTER ELECTRIC SIGNAL PAD100-PSSA 3 DUAL INPUT CONTACT MODULE POTTER ELECTRIC SIGNAL PAD100-DIM 18 HORN/STROBE, 2 WIRE, M -C, RED, WALL POTTER ELECTRIC SIGNAL HS-24WW 20 STROBE, M -C, WHITE, WALL POTTER ELECTRIC SIGNAL S-24WW 1 STROBE, M -C, RED, WALL POTTER ELECTRIC SIGNAL S-24WR 1 6IN VIBRATING FIRE BELL 24V RED POTTER ELECTRIC SIGNAL MBA -624 5 EOL 5.1K POTTER ELECTRIC SIGNAL EOL -5.1 rrternational. Buddha D.ynarrric Lan guage,Centet LoNIst.a Apartments pit us Cradit Un( F P Office Sniutions Cert r [11v,1 f:J les tu) Sou1hcente 44, er Of se nded:Stap Arrmric:a Awila 4-4 ;,0 VICINITY MAP DRAWING INDEX SHEET NO. SHEET DESCRIPTION FA0.1 TITLE SHEET FA1.1 FLOOR PLAN - FIRE ALARM SYSTEM FA2.1 FIRE ALARM SYSTEM RISER DIAGRAM AND BATTERY CALCULATIONS INPUTS AND ACTIONS \\J;44,\ � SA OUTPUTS AND CONTROLS �O�Q Og44o ! ,o G �'P cycti OPERATE ALL AREA EVACUATION SIGNALS SOUND LOCAL PIEZO AT FACP INDICATE DEVICE AT FACP SEND ALARM SIGNAL TO C.S. MONITORING SEND TROUBLE SIGNAL TO C.S. MONITORING SEND SUPERVISORY SIGNAL TO C.S. MONITORING SEND WATERFLOW SIGNAL TO C.S. MONITORING ILLUMINATE LED ON DETECTOR PAtO JAM 2) 201C cc TUKWILA FRE DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36" va N 101r.a N01po d ItN0f: F0•20 H 6) • It "d co 13 y LU • 1L 2 Q n 8 1,1 OI:: acti LLiil OO:71.° 00i1-iN ELE.CTRiC Co. Po Box 1 030 M1LTON, vvik 98354 Phlona: (253) 984-1611 Fax: (253) 984-1613 z ADRIAN M. STEIK Senlor Englneering Technician, Level 4 NICET Certifcation Number. 093706 Authorizing Signature: -3-0 SHEET TITLE: DRAWN BY: SAFE Consulting CHECKED BY: Adrian M. Steik PLOT DATE: 12/23/17 PROJECT NUMBER: 17-236 FAOIJ SHEET NUMBER: BACKFLOW PREVENTER TAMPER BACKFLOW PREVENTER TAMPER WET SYSTEM TAMPER SWITCH DRY SYSTEM TAMPER SWITCH WET SYSTEM FLOW SWITCH DRY SYSTEM FLOW SWITCH LOADING DOCK 165 STORAGE 166 TRAINING/ CONFERENCE ROOM 167 STORAGE 164 D SLC1.0005 D SLC1.0004 D SLC1.0003 COLLABORATIVE WORK/LOUNGE 163 BREAKROOM 162 110CD FA-NAC4.011 i FA-NAC4 EOL 5.1K FA-NAC4.010 • 75CD FA-NAC4.006 ::1\ 30CD GAME ROOM 160 WAR ROOM 155 MOTHER'S ROOM 154 MEN'S RIR 152 WOMEN'S R/R 151 OPEN WORKSTATIONS 144 SERVER/ STORAGE 141 PRIVATE OFFICE 140 15CD FA-NAC4.005 MOP 158 FA-NAC4.004 75CD 15CD FA-NAC3.005 ; , CLOSET 157 COPY/PRINT FA-NAC3.004 '• 30CD 147 15CD FA-NAC3.006 15CD ;`� FA-NAC3.007 0 15CD BAR , FA-NAC4.007 173 FA-NAC4t.008 30CD I` N 15CD FA-NAC4.009 FA-NAC5.001 -� 75CD \, FA-NAC5.002 "! it It 0 EOL 5.1K FA-NAC1 : FA-NAC1.008 30CD 75CD FA-NAC1.007 FA-NAC1.006 75CD FA-NAC1.005 :75CD HALLWAY 172 SAMPLING/ WORKROOM 174 15CD ? FA-NAC4.002 A' ADA R/R 151E 15CD FA-NAC3.001 75CD FA-NAC4.001 CLOSET 106 75CD FA-NAC3.002 ' HALLWAY 149 15CD FA-NAC2.002 FA-NAC2.003 75CD OPEN WORKSTATIONS [_...._115 .__.I 15CD 15CD. FA-NAC2.004 FA-NAC2.005 SALES TEAM AREA 177 FA-NAC1.001 75CD 75CD.\ FA-NAC2.001 SLC1.0002 OPEN MEETING 1031 'SLC1.0001 ,1i ADMIN FA-NAC1.004 75CD FA-NAC1.002 30CD 182 FA-NAC5 EOL 5.1K FLOOR PLAN - FIRE ALARM SYSTEM SCALE = 1/8" = 1' 0" 0 4' 8' 12' 16' STORAGE 170 30CD FA-NAC1 '003 0, PRIVATE OFFICE 180 WAR ROOM RECEPTION/ LOBBY 10z.J 110 WAR ROOM 111 ADMIN OFFICE AREA r 139 STAIRS 138 0 15CD FA-NAC3.008 1. 30CD FA-NAC3 EOL 5.1K D. FA-NAC3.010 75CD FA-NAC3.009 OPEN COLLABORATIVE 118 30CD FA-NAC2.006 i OPEN WORKSTATIONS 134 FA-NAC2.007 75CD • LARGE CONFERENCE -- 119 PROJ. MGR AREA 123 SALES TEAM AREA 130 10 ELECTRIC. CO, PG BOX 1 030 M 1 LTO RI , WA 98354 Phone: (253) 984-1611 Fax: (253) 984-1613 DISPLAY/ WORK COUNTER 125 FA-NIAC2.008 30CD\_, FA-NAC2 , EOL 5.1K FA-NAC2.009 PRIVATE OFFICE ADRIAN M. STEIK Senior Engineering Techniclen, Level 4 NICET Certlfcation Number. 093706 Authorizing Signature: DRAWN BY: CHECKED BY: Adrian M. Steik PLAN NORTH 4 PLOT DATE: 12/23/17 PROJECT NUMBER: 17-236 DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36" FA1I1 SHEET NUMBER: Battery Calculations for Panel: FACP Part No:3992717 - IPA -4000, 4064 POINT RELEASING FACP Part No. Qt Description Standby Total Standby Alarm Total Alarm 3992717 Panel Equipment HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD ' 25'-9 0.144A IPA4000 MB 1 IPA4000 MB 0.160A 0.160A 0.200A 0.200A 003 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD Total Panel Stby 0.160A Total Panel Alarm 0.200A 0.042A 005 Peripheral Devices STROBE, M -C, WHITE, WALL, 15CD 26'-0 0.042A 006 S-24WW 6 STROBE, M -C, WHITE, WALL (Notification) 0.000A 0.000A 0.058A 0.348A HS-24WW 4 HORN/STROBE, 2 WIRE, M -C, RED, WALL (Notification) 0.000A 0.000A 0.086A 0.344A HS-24WW 13 HORN/STROBE, 2 WIRE, M -C, RED, WALL (Notification) 0.000A 0.000A 0.144A 1.872A EOL -5.1 5 EOL 5.1 K (Notification) 0.000A 0.000A 0.000A 0.000A S-24WW 14 STROBE, M -C, WHITE, WALL (Notification) 0.000A 0.000A 0.042A 0.588A HS-24WW 1 HORN/STROBE, 2 WIRE, M -C, RED, WALL (Notification) 0.000A 0.000A 0.189A 0.189A S-24WR 1 STROBE, M -C, RED, WALL (Notification) 0.000A 0.000A 0.116A 0.116A MBA -624 1 61N VIBRATING FIRE BELL 24V RED (Notification) 0.000A 0.000A 0.060A 0.060A PSA 1 PHOTO SMOKE DETECTOR (Signaling line) 0.000A 0.000A 0.001A 0.001A APS -SA 1 PULL STATION, SINGLE ACTION, ADDRESSABLE Si.nalin. line 0.000A 0.000A 0.000A 0.000A DCM-4 3 DUAL INPUT CONTACT MODULE (Signaling line) 0.000A 0.000A 0.001A 0.003A Total Peripheral Stby 0.001A Total Periph Alarm 3.522A Total Standby Amps 0.161A Total Alarm Arno__ 3.722A Standby time: 24 Hrs 3.856Ah Alarm time: 5 Min 0.31Ah Battery requirement: 4.166Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 4.999Ah Circuit Calculations Panel: FACP Card: 00 Circuit:FA-NAC1 Device 001 002 003 Part No 3992717 HS -24W W HS-24WW S-24WW CircuitName: FA-NAC1 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 3.000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Minimum operating voltage: 16V Appliance Desc Panel HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD HORN/STROBE, 2 WIRE, M -C, RED, WALL, 30CD STROBE, M -C, WHITE, WALL, 30CD 004 005 006 007 008 008 HS-24WW HS -24W W HS -24W W HS-24WW HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD HORN/STROBE, 2 WIRE, M -C, RED, WALL, 30CD Distance Current Volt ge Voltage Drop 20.4V 25'-0 0.144A 20.254V (0.146V) 22'-6 0.086A 20.14V (0.114V) 29'-7 14'-1 0.058A 0.144A 20.008V 19.951V 55-1 35'-11 0.144A 0.144A 32'-8 0.144A 12'-2 0.086A EOL -5.1 EOL 5.1K 2'-8 229'-8 0.000A 19.776V 19.693V 19.647V 19.64V 19.64V (0.133V) (0.057V)_ (0.175V) (0_083V) (0.047V) (0.006V) (0V) 0.950A Total Current: 0.950A (Total VDrop Percent:3.72%) Total Voltage Drop : 0.76V Circuit Calculations Panel: FACP Card: 00 Circuit:FA-NAC2 CircuitName: FA-NAC2 Circuit Type: Notification Terminal Voltage: 20.4V:DC Cable: 14/2 SOL JKT FPLR 1M RL RED Calculations based on Running Tota Design Criteria: Ambient temperature: 167°F Minimum Amperage: #14 Length. operat�in Distance 3.000A voltage: 16V Current Voltage 20.4V Voltage Drop Device Part No Appliance Desc Panel 3992717 001 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD ' 25'-9 0.144A 20.283V 20.164V 20.1V 20.031V 19.974V 19.958V (0.117V) (0.119V) (0.064V) (0.069V) (0.057V) (0.016V) (0.065V) (0.019V) (0.011V) (OV) 002 S-24WW STROBE, M -C, WHITE, WALL, 15CD 32'-7 19'-1 0.042A 0.144A 003 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 004 S-24WW STROBE, M -C, WHITE, WALL, 15CD 27'-8 0.042A 005 S-24WW STROBE, M -C, WHITE, WALL, 15CD 26'-0 0.042A 006 S-24WW STROBE, M -C, WHITE, WALL, 30CD 8'-3 0.058A 007 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 40'-9 27'-5 0.144A 0.058A 0.058A 19.893V 19.873V 19.863V 008 S-24WW STROBE, M -C, WHITE, WALL, 30CD 009 S-24WW STROBE, M -C, WHITE, WALL, 30CD 30'-5 009 EOL -5.1 EOL 5.1K 2'-10 240'-9 0.000A 0.732A 19.863V 2'-6 0.000A 19.798V (0V) Tota Current: 0.732A (Total VDrop Percent:2.63%) Total Voltage Drop : 0.537V Circuit Calculations Panel: FACP Card: 00 Circuit:FA-NAC3 CircuitName: FA-NAC3 Circuit Type: Notification Terminal Voltage: 20.4V Cable: 14/2 SOL JKT FPLR 1M RL RED Calculations based on Running Tota Design Criteria: Ambient temperature: 167°F Minimum DC Amperage: #14 Length. operating Distance 3.000A voltage: 16V Current Voltage 20.4V Voltage Drop Device Part No Appliance Desc Panel 3992717 001 S-24WW STROBE, M -C, WHITE, WALL, 15CD 61'-2 0.042A 0.144A 20.144V 20.077V (11256V) (0.067V) 002 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 16'-8 003 S-24WW STROBE, M -C, WHITE, WALL, 15CD 6'-0 20'-4 0.042A 0.086A 0.042A 0.042A 0.042A 20.058V 20.002V 19.989V 19.914V 19.867V (0.018V) (0.056V) (0.014V) (0.075V) (0.047V) 004 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 30CD 005 S-24WW S-24WW STROBE, M -C, WHITE, WALL, 15CD STROBE, M -C, WHITE, WALL, 15CD 5'-7 36'-10 27'-3 006 007 S-24WW STROBE, M -C, WHITE, WALL, 15CD 008 S-24WW STROBE, M -C, WHITE, WALL, 15CD 25'-6 0.042A 19.828V (0.039V) 009 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 13'-10 34'-10 0.144A 0.058A 19.811V 19.798V (0.017V) (0.012V) 010 S-24WW STROBE, M -C, WHITE, WALL, 30CD 010 EOL -5.1 EOL 5.1K 2'-6 0.000A 19.798V (0V) 0.189A 011 EOL -5.1 250'-6 0.684A 0.000A 0.975A 19.114V (Total VDrop Tota Current: 0.684A Percent:2.95%) Total Voltage Drop : 0.602V FIRE ALARM BATTERY & VOLTAGE DROP CALCULATIONS 0,11, SCALE = NOT TO SCALE EOL 5.1K FA-NAC4 110CD FA-NAC4.011 EOL 5.1K cx FA-NAC3 75C0 FA-NAC4•010 30CD FA-NAC3.010 EOL 5.1K a.' FA-NAC2 Ck FIRE ALARM RISER DIAGRAM SCALE = NOT TO SCALE 15CD FA-NAC4.009 75CD FA-NAC3009 30CD FA-NAC2.009 EOL 5.1K FA-NAC1 Circuit Calculations Panel: FACP Card: 00 Circuit:FA-NAC4 CircuitName: FA-NAC4 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Minimum o•eratin• 3.000A voltage: 16V Current Voltage 20.4V Voltage Drop Device Part No Desc Distance 3992717 _Appliance Panel 001 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 82'-3 0.144A 0.042A 0.042A 19.909V 19.792V 19.724V 0.491VZ 0.117V) 0.068V) 0.142V) 0.074V) 0.107V) (0.07V1 Jp.051V) (0.023V) (0.133V) (0.01V) 002 S-24WW STROBE, M -C, WHITE, WALL, 15CD 23'-4. 003 S-24WW STROBE, M -C, WHITE, WALL, 15CD 13'-7 004 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 30'-6 0.144A 0.042A 19.582V 19.508V 005 S-24WW STROBE, M -C, WHITE, WALL, 15CD 19'-10 006 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 30CD 31'-3 0.086A 0.042A 19.401V 19.331V 19.28V 19.257V 19.124V 19.114V 007 S-24WW STROBE, M -C, WHITE, WALL, 15CD 23'-11 008 S-24WW STROBE, M -C, WHITE, WALL, 30CD 18'-11 0.058A 009 S-24WW STROBE, M -C, WHITE, WALL, 15CD 9'-11 65'-1 0.042A 0.144A 010 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 75CD 011 HS-24WW HORN/STROBE, 2 WIRE, M -C, RED, WALL, 110CD 9'-3 0.189A 011 EOL -5.1 EOL 5.1K 2'-0 329'-10 0.000A 0.975A 19.114V a) Tota Current: 0.975A (Total VDrop Percent:6.30%) Total Voltage Drop : 1.286V Circuit Calculations Panel: FACP Card: 00 Circuit:FA-NAC5 CircuitName: FA-NAC5 Circuit Type: Notification Terminal Voltage: 20.4V:DC Cable: 14/2 SOL JKT FPLR 1 M RL RED Calculations based on Running Tota Design Criteria: Ambient temperature: 167°F Minimum Amperage: #14 Length. operating Distance 3.000A voltage: 16V Current Voltage 20.4V Voltage Drop Device Part No Appliance Desc 3992717 Panel 001 MBA -624 6IN VIBRATING FIRE BELL 24V RED 146'-2 0.060A 20.242V (0.158V) 002 S-24WR STROBE, M -C, RED, WALL, 75CD 1'-8 1'-8 0.116A 0.000A 20.241V 20.241V (0.001V) (VI DCM-4 EOL -5.1 EOL 5.1K 0.000A 0004 DCM-4 149'-6 0.176A 0.000A (Total VDrop Tota Current: 0.176A Percent:0.78%) Total Voltage Drop : 0.159V Circuit Calculations Panel: FACP Card: 00 Circuit:SLC1 CircuitName: SLC1 Circuit Type: Signaling Zine/Potter - SLC Terminal Voltage: Cable: 16/2 SOL JKT FPL 1M RL RED Calculations based on Running Tota Design Criteria: Ambient temperature: 167°F Minimum 20.2V:DC #16 Length. operating Distance Amperage: voltage: 16V Current 1.000A Voltage 20.2V Voltage Drop Device Part No Appliance Desc 3992717 Panel 0001 APS -SA PULL STATION, SINGLE ACTION, ADDRESSABLE 1'-8 0.000A 20.2V (0V) (0V) (OV) 0002 PSA PHOTO SMOKE DETECTOR 4'-8 0.000A 20.2V 20.2V 0003 DCM-4 DUAL INPUT CONTACT MODULE 184'-2 0.000A 0004 DCM-4 DUAL INPUT CONTACT MODULE 2'-3 0.000A 20.2V (OV) 0005 DCM-4 DUAL INPUT CONTACT MODULE 2'-4 0.000A 0.001A 20.2V (0V) 195'-1 Total Current: 0.001A (Total VDrop Percent:0.00%) Total Volta • e Dro • : OV 30CD FA-NAC4.008 15CD FA-NAC3.008 30CD FA-NAC2.008 30CD FA•NAC i•008 15CD FA-NAC4.007 15CD FA-NAC3.007 7500 FA-NAC2.007 7500 FA-NAC1.007 30CD FA-NAC4.006 15CD FA-NAC3.006 30CD 15CD FA-NAC4.005 15CD FA-NAC3.005 15CD FA-NAC2.006 FA-NAC2.005 75CD FA-NAC1.006 75CD FA-NAC1.005 75CD FA-NAC4✓004 30CD FA-NAC3.004 15CD FA-NAC2.004 75CD FA-NAC1.004 EOL 5.1K ca ... FA-NAC5 15CD FA-NAC4.003 15CD FA-NAC3.003 7500 FA-NAC2.003 30CD FA-NAC1.003 75CD FA-NAC5.002 15CD FA-NAC4.002 75CD FA-NAC3:002 15CD FA-NAC2.002 30CD FA-NAC1.002 FA-NAC5.001 7500 FA-NAC4701 15CD • FA-NAC3.001 7500 FA-NAC2001 7500 FA-NACI•001 FACP F SLC1.0001 SLC1.0002 SLC1 0003 D SLC1.0004 SLC1.0005 Level 0 DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36" N ri NUlm N`0 1 +" L1J 0� 40 0 H `� • o • Qoo W • .LLE Q I - °u • (n 0 - 2Q N acHo -c IL NIC Oit.c CO 0 0 13 01�• S 0 3 T-1 vi O. 3 ELECTRIC. CO, PO BOK -1 030 IV11 LTO N , WA 98354 Phone: (253) 984-1611 Fax: (253) 984-1613 ADRIAN M. STEIK Senior Engineering Technician, Level 4 NICET Certlrcetlon Number. 0937060 3 Authorizing Signature: (i.-- "` _ DRAWN BY: CHECKED BY: PLOT DATE: PROJECT NUMBER: FA2.1 SHEET NUMBER: