HomeMy WebLinkAboutPP - 1251 ANDOVER PARK WEST - DANIA - PERMITS AND PLANS1251 ANDOVER PARK WEST ASSOCIATED PERMITS 18-F-153 18-F-070 443ttliWitt4e SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 I2M FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 3523049103 Site Address: 1251 Andover Pk W Tukwila, WA 98188 Suite Number: Floor: e Tenant Name: V01/44/a 0\ G • New Tenant? ❑ - Yes ENo Property Owner's Name: Dania Inc. Mailing Address: 2250 S McDowell Blvd Petaluma CA 94954 CONTACT PERSON -if there are questions about the submittal. Name: Manny Ornelas Day Telephone: 206-436-5301 Company Name: Washington Alarm Mailing Address: 2030 Airport Way S City State Zip permits@washingtonatarm.com City E-mail Address: Contractor's City of Tukwila Business License number: BUS -0992857 State Zip Fax Number: 206-322-7214 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 1 ,000 Scope of Work (please provide detailed information): Connection of a new HVAC Smoke Duct Detector to existing 1912 FACP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE N UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID `R BUILDING OWNER 0 c.aUir 0 • I AGENT: Signature: �'? __t 20r Date: 3/29/2018 Print Name: Manny Ornelas 1IIUK Iky TFelephoIRne:ir- 206-436-5301 Plan Permit App.doc 8/22/14 C C /P Z6b TFD FP Form 8 4 ittN/ SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 3523049103 Site Address: 1251 Andover Pk W Tukwila, WA 98188 Suite Number: Floor: Tenant Name: Dania Inc. New Tenant? ❑ - Yes ENo Property Owner's Name: Dania Inc. Mailing Address: 2250 S McDowell Blvd Petaluma CA 94954 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Manny Ornelas Day Telephone: 206-436-5301 Company Name: Washington Alarm Mailing Address: 2030 Airport Way S ermits�washin tonalarm.com City State Zip E-mail Address: P g Fax Number: 206.322-7214 Contractor's City of Tukwila Business License number: BUS -0992857 Total number of new/relocated devices or sprinkler heads: 6 Valuation of Project (contractor's bid price): $ 4,200 Scope of Work (please provide detailed information): Installation of a new Fire Alarm control panel & AES radio for monitoring of an existing fire alarm system. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW JIORIZE GENT: Signature: PPP- anny Ornelas Print Name: Plan Permit App doc PAID IRI_ 312018 Date: .71 31 lb TUKWILOIte: 206-436-5301 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: N t Type of Inspection:r 4fr,1,24.0 Address: Suite #: fl 4.5-7 / Contact Person: Special Instructions: 41 Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: r'etv,-4 /9-ae--0 Fps' A-Evi-e-e-5 c�., �.ct cw w,ll lu/'P*'� wl�c.H. ct��fwc- lotiec.-i-s Needs Shift Ins ction: Sprinklers: C(••€"5 Fire Alarm: tel" Hood & Duct: Monitor: fit/ 41 /4-‘ Pre -Fire: Permits: Occupancy Type: S-- I Inspector: .F1vt, Date: VG? /1 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Word/Inspection Record Form.Doc 3/14/14 Zip: T.F.D. Form F.P. 113 l INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit -F-153 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Type �a A. ` of Inspection - Address: Suite #: /-7,--/ _ _ Contact Person: Special Instructions: Phone No.: Approved per ap licable codePt/ CiAreZlek* COMMENTS Corrections required prior to approval. /IAD Hai( cdo- l'tew isqviv-e, g P(eArA /10 /-' �"D laoua8 (-(044 /‘ /,(66e., Ahod- -aze--- e 11WrWig-e) 01-10tt" te-eAdvS Slibr-tv owe_ Needs Shift Inspection: Date: I�/12l(q Sprinklers: ti Fire Alarm: y Hood & Duct: Monitor: IIA a4#- v'--- Pre -Fire: Permits: Occupancy Type: 5, Inspector: pleyl 91— Date: I�/12l(q Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 4,1404 WASHINGTON AL Record of Completion Fire Alarm and Fire Detection Systems Proudly Pro\iding Quality, Service & Integrity To The Pacific Northwest Since 1943 Date: 1 ZD e Permit #: /9' / SS Name of Facility: bog( #..0.- 'F✓r;n; e.._ Property Address /Z57 Je1 v1 J.J . City/State/Zip: 1:ki,tl, rte, iJ4 98/88 Installing Company: sL r,- 4644,41 Address: 20 S. City/State/Zip: Installer's Name (PRINT): Ori N J v1 License and/or Certificate: /V Occupied as: BoS #..ems — ori' Qyner or Representative: 12o7.5 we J- f Phone:ZO6 — 5751- /9 / b Authority having Jurisdiction: % v ki,,, L /.ev4i r Address: Phone: do --S7 S— zi9/0 General Contractor: Electrical Contractor: nl/A basks b r / . (4.1 to FACP Equip. Manf: 5;14#14-14#;51A4— Model No.: 67760 The State or Local Electrical Permit "Final" inspection was completed on (date). This system has been installed, pre -tested and operates in accordance withh standards listed below, was inspected by tat 5 isr1 A(9 444 on f t�1- 74) (6 and includes the devices listed below. ✓/ NFPA 72 NFPA 70, National Elect. Code, Article 760, Manufacturer's Instructions. Manufacturer's Instructions. International Fire Code Other (specify) 2030 Airport Way S Seattle WA 98134-1603 UL LISTED CENTRAL STATION LICENSED & BONDED ELECTRICAL CONTRACTOR WASH IA1282C3 www.washingtonalarm.com P: 206-328-3288 F: 206-322-7214 WASH I NGTON ALA System m Signed Remote Date i( System Firmware: b Installed Version: Checksum: Date: Initial program Installation: le,/l7'fZo l$ Date: Revisions and Reasons: A amu(. 14-419 In cx, iviCe• Programmed by: JL1 %�i v (r k- t tillyS(t i ft4.t,)n /Kt uwt jJ ce,4-ff 14 3 1 Equipment Installed and Tested Control Panel e of / Make/Model 5` L4 6 D0 Manual Station / of / Make/Model 5- k is g jL-iPul (-DA Smoke Detectors / of / Make/Model ff� lkvr�%4 SIL - C4/ Heat Detectors Q'' of a Make/Model Duct Detectors 2- of 2— Make/Model S; , A/V Device I of t Make/Model Sy vt- - P2 it) 1(�— Audio Devices a of Make/Model Visual Devices 3— of 3 Make/Model 5y,' i ,.�,>o� 5C -C)1 --- Auto Door Release / of / Make/Model SIL—Peri Trouble Indicators 'L of 2 Make/Model Proudly Providing Quality, Service & Integrity To The Pacific Northwest Since 1943 entral Station /� ?-z i8 iS;o/L'K�/ by 44.46 Batteries j of 2 Make/Model -VA-(e.-64k 4St_A /D 7 Readings Battery Full Load Charge 26.7c4 Generator of HVAC controls of Make/Model Make/Model Fire Alarm Dialer ( of / Make/Model 455-7-1.07-Fi Monitored by 061614;#1) 10),1 j(e044 Phone ZOfr-3ZPy /get) Annunciator ( of ( Make/Model S ( " kt..30 51960/� Sprinkler System (Fire Alarm connections only) 2030 Airport Way S UL LISTED CENTRAL STATION Seattle WA 98134-1603 LICENSED & BONDED ELECTRICAL CONTRACTOR WASHIA1282C3 www.washingtonalarm.com P: 206-328-3288 F: 206-322-7214 10, WASHINGTONAL Water Flow S 3 of .3 Valve Tamper w. Sw.' of 3 of3 Eley.PIV Alarm Bell pof Proudly Providing Quality, Service & Integrity To The Pacific Northwest F , . Since 1943 Make/Model Make/Model Make/Model 5:k.•41--4.7/tl; O.°I Make/Model Automatic time delay of General Alarm minutes. None Installed X Do you meet audible/visible requirements of NFPA 72, Section 7? • No Was the test of Alarm System on emergency power satisfactory? • Yes • No Comments ()hes ✓I01' �[,1r/� p er,• �/�iy.S u�1 CERTIFICATIONS AND APPROVALS Property or Owner Representative: I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed: Organization: Title: Date: Phone: Authority Having Jurisdiction: I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and specifications, with its approved sequence of operations, and with all NFPA standards cited herein. Signed: Printed: Organization: Title: Date: Phone: 2030 Airport Way S Seattle WA 98134-1603 UL LISTED CENTRAL STATION LICENSED & BONDED ELECTRICAL CONTRACTOR WASH IA1282C3 www.washingtonalarm.com P: 206-328-3288 F: 206-322-7214 5D/ 25' Rfrt (0 VIA* Nftit,r xklalitsieA ACCEPTED 15 Without Comments o As Noted in Red O Per The Attached Letter A NI - TLAILL,,, ► l4- 1\\ W4" E 5 These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted c.:tandards and ordinances The responsibility for the deguacy of design rests totally with the designer. Additions, deletions o, :-visions to these drawings after this date will void this acceptance and will regLire a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bu eau. Date: LI- ID By 51I TUKWILA FIRE DEPARTMENT Please call 205-573-4407 and ghee this Fire Permit No. t_nd exact address for shut - .;:own or restoration approval. PAID IAP, 2O TUKWILA, FIRE - cc 120 VAC BELL/1J (BY OTHERS) V -I O Without Comments "' As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances rhe responsibility for the adequacy of design ;'oasts totally with the designer. Additions, cf,letions =` revisions to these drawings after this date wit! void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: $- 9-I By: S I I ._ IM VS VS,IM 5T1 -270-q1 IM VS VS M DOC P FWFM �T M5 M-2 THRU THRU M7 M-4 SLC FROM FACP SHIPPING AND RECIEVING 1/;;:#16/2 TWP .5 FROM FACP UKWILA FIRS, DEPARTMENT lease calf 206-575-4407 and Siwe this Fire Permit No. exact address for shut- ,..,ovvri #16/2 TWP SHOW ROOK BUILDING FIRE ALARM PLAN SCALE: 1/16"=1'-o" 0 8' 18' 32' #14/2 AWG FROM FACP-1 MAIN ENTRANCE WP 75 N1-1 MD !tit_ 312018 TUKWILA FIREo shop drawings seated by. 5794 W. 4800 So. Hooper, UT 84315 Office: 801.985.0410 www.unicod.net NICET III Fire Alarm Systems Date: Signature 7/30/2018 Fire Protection Engineering Technology Fire t3ems Cert. N No..m 1 1388 751 Exp 5/1/2019 O N O M 2 0 H a C.) U) w EW & APPROVAL 0 N rn 1253 S JACKSON ST. SEATTLE, WA 206-328-3288 TU - x ILA, WA 98188 FIRE ALARM PLAN CRL UNICAD JOB #18461 BRADY B. HAWS NICET III 138751 Point to Point NAC Voltage Drop Calculation 7/30/2018 FACP Battery Calculation 7/30/2018 PROJECT NAME: TEMPLATE Required Standby Time: Required Alarm Time: 24 5 Hours Minutes AC Branch Current AC Branch Current: Amps CO 120V Regulated Load in Standby 16.0 370 Device Type Number of Devices 14 Current (Amps) 3.00 Total Current (Amps) FACP MAINBOARD SMOKE DETECTOR MONITOR MODULE PULL STATION ANNUNCIATOR 1 1 6 1 1 X X X X X 0.20000 0.00030 0.00040 0.00038 0.02000 = = = = = 0.20000 0.00030 0.00240 0.00038 0.02000 TOTAL STANDBY LOAD 0.22308 Regulated Load in ALARM 370 NAC -1 Device Type Number of Devices WATER FLOW SWITCH Current (Amps) Ea Total Current (Amps) FACP MAINBOARD SMOKE DETECTOR MONITOR MODULE PULL STATION ANNUNCIATOR FACP-1 (See Voltage Drop Calculations) 1 1 6 1 1 1 X X X X X X 0.36500 0.00030 0.00040 0.00500 0.02500 0.17600 = = = = = = 0.36500 0.00030 0.00240 0.00500 0.02500 0.17600 TOTAL ALARM LOAD 0.57370 Battery Requirements Standby Load Required Standby Time in Hours Current (Amps) 0.22308 X 24.00000 = 5.35380 Alarm Load Required Alarm Time in Hours Current (Amps) 0.57370 X 0.08333 = 0.04781 Total Ampere Hours (before derating factor) 5.40161 Derating Factor X 1.2 TOTAL AMPERE HOURS REQUIRED = 6.48193 BATTERIES TO BE PROVIDED (2 - 12v) 8 Mi DESCRIPTION Point to Point NAC Voltage Drop Calculation 7/30/2018 Project Name Circuit Number Nominal System Voltage Minimum Device Voltage Distance from source to 1st device Wire Gauge for balance of circuit Max Output Current Total Circuit Current End of Line Voltage DESCRIPTION TEMPLATE FACP-1 ACTIVATE AUDIBLE SUPERVISORY SIGNAL volts volts feet amps amps volts Wire Gauge Resistance Per 1000 3.07 3.07 20.4 16.0 370 14 rn 14 Lr ` 3.00 0.176 20.00 Circuit is within limits I Device Current Distance previous Voltage at Drop from Percent device Device source Drop 370 20.00 0.400 1.96% Device 1 0.176 Totals 0.176 370 NAC -1 Notes: Wire resistance is doubled in the calculations for two wires (Positive and Negative). The voltage calculated to the last device must not be lower than the manufactures listed minimum operating voltage (IE: rated operating voltage 16-33 WC (24 VOC nominal)). MODEL 5860 REMOTE ANNUNCIATOR SBUS #14/4 AWG -' 120 VAC S -- (DEDICATED CKT.) COM AES -7788F WIRELESS FIRE ALARM COMMUNICATOR RJ31X RJ31� FACP SYMBOL DESCRIPTION MOUNTING ACTIVATE SUPERVISORY INDICATOR ACTIVATE AUDIBLE SUPERVISORY SIGNAL ACTIVATE TROUBLE INDICATOR `FRCP FIRE ALARM CONTROL PANEL WALL -TOP ® 66" TRANSMIT TROUBLE SIGNAL FIRE SYSTEM ANNUNCIATOR WALL -TOP 0 66" rn Lr ` KNIGHT SILENT COM O2 T IntelliKnight MODEL 5700 CEILING "C00 LLII w a rn r DIAL=R MANUAL PULL STATION NAC -1 24V FROM POWER FACP NAC -2 WATER FLOW SWITCH BY OTHERS Ea • VALVE SUPERVISORY SWITCH / VS BATTERY f BATTERY #14/2 AWG EOL EOL FIRE ALARM RISER DIAGRAM VS M-3 VS VS VS WF M-4 M-5 M-6 M-7 FIRE ALARM SYMBOL LEGEND NM: AU. SYMBOLS MAY NOT BE USED ON THIS PROJECT SYMBOL DESCRIPTION MOUNTING ACTIVATE SUPERVISORY INDICATOR ACTIVATE AUDIBLE SUPERVISORY SIGNAL ACTIVATE TROUBLE INDICATOR `FRCP FIRE ALARM CONTROL PANEL WALL -TOP ® 66" TRANSMIT TROUBLE SIGNAL FIRE SYSTEM ANNUNCIATOR WALL -TOP 0 66" FSA WIRELESS FIRE ALARM COMMUNICATOR WALL -TOP ® 66" COM O2 T THERMAL/PHOTO ELECTRIC SMOKE DETECTOR CEILING ADDRESSABLE MONITOR MODULE FIELD VERIFY r MANUAL PULL STATION WALL ® 48" P WATER FLOW SWITCH BY OTHERS Ea VALVE SUPERVISORY SWITCH BY OTHERS VS R. BELL BY OTHERS igKi WP WEATHER PROOF HORN / STROBE WALL 80"-96" ABBREVIATION DESCRIPTION VALVE TAMPER SWITCHES ®4 75 $�A 30 E EXISTING A �GW) G WITH GUARD P PENDANT MOUNT OO ,r DEVICE ADDRESS -\ CI L1D001 OR DO1 b - oENOTEs LOOP (D or M - ENOTES DEFECTOR 09 MODULE #) R RESIDENTIAL (110V) S SOUNDER BASE WP WEATHER PROOF EOL END OF LINE RESISTOR EOLR END OF LINE RELAY - 16 2 TWP AWG AMERICAN WIRE GAUGE TWP TWISTED PAIR WIRE TYPE ABBREVIATED CONDUCTOR COUNT TWSP TWISTED SHIELDED PAIR FPLP FIRE POWER LIMITED PLENUM WIRE SIZE FPLR FIRE POWER LIMITED RISER OPEN CIRCUIT OF CABLES (IF EDED) D NLY 1 CABLE NEEDED) NAC NOTIFICATION APPLIANCE CIRCUIT SLC SIGNALING LINE CIRCUIT OPERATIONS MATRIX FIRE ALARM INPUT 0 0 0 ff w rz ACTIVATE ALARM INDICATOR I ACTIVATE AUDIBLE ALARM ACTIVATE SUPERVISORY INDICATOR ACTIVATE AUDIBLE SUPERVISORY SIGNAL ACTIVATE TROUBLE INDICATOR ACTIVATE AUDIBLE TROUBLE INDICATOR TRANSMIT ALARM SIGNAL TRANSMIT SUPERVISORY SIGNAL TRANSMIT TROUBLE SIGNAL ACTIVATE NOTIFICATION APPLIANCES SMOKE DETECTORS PULL STATIONS 0 WATERFLOW SWITCHES VALVE TAMPER SWITCHES FIRE ALARM AC POWER FAIL FIRE ALARM LOW BATTERY OPEN CIRCUIT GROUND FAULT NAC SHORT CIRCUIT LOSS OF AC TO BUILDING -4" MIN A/C SUPPLY OR RETURN DIFFUSER 4' MIN 12' MAX EVER HERE CEILING -MOUNTED HEAT DETECTOR AUDIBLE/VISUAL 6" MIN. AND/OR VISUAL ONLY APPLIANCE E WALL -MOUNTED HEAT DETECTOR 80"-96" TO LOWEST PART OF LENS 90" MIN. WHERE CEILING HEIGHT ALLOWS AUDIBLE -ONLY APPLIANCES GENERAL NOTES: 1. SCOPE OF WORK: THIS PROJECT SHALL INCLUDE THE INSTALLATION AND MONITORING OF A NEW FIRE ALARM PANEL AND AES COMMUNICATION, TO AN EXISTING SYSTEM, WAI CURRENTLY MAINTAINS. 2. THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. 3. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 4. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. 5. FIRE RATINGS SHALL BE MAINTAINED FOR ALL PENETRATIONS THROUGH FIRE -RATED CONSTRUCTION. 6. POWER FOR ALL FIRE ALARM PANELS AND FIRE ALARM POWER SUPPLIES MUST BE PROVIDED BY A DEDICATED AC BRANCH CIRCUIT. THE LOCATION OF THE BRANCH CIRCUIT BREAKER SHALL BE PERMANENTLY IDENTIFIED AT THE CONTROL UNIT AND SHALL HAVE A RED MARKING IN ACCORDANCE WITH NFPA 72. 7. POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN CABINET. ALL POWER -LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NONPOWER -LIMITED CIRCUIT WIRING. FURTHERMORE, ALL POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. 8. WHEN UTILIZING CLASS "A" CIRCUITS, SEPARATE OUTGOING AND RETURN CONDUCTORS OF CLASS "A" CIRCUITS BY A MINIMUM OF 12" WHERE RUN VERTICALLY AND 48" WHERE RUN HORIZONTALLY. 9. WHEN UTILIZING SHIELDED CABLE TIE SHIELDS THROUGH AND INSULATE AT EACH JUNCTION BOX. INSULATE AND TAPE BACK AT END. 10. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT MANUFACTURER FOR THE INTENDED PURPOSE. 11. SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN-UP IS COMPLETED AND FINAL. 12. LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. WALL -MOUNTED SMOKE DETECTORS SHALL BE LOCATED A MINIMUM OF 4" AND A MAXIMUM OF 12" FROM CEILING. 13. PROVIDE SYNCHRONIZATION OF ALL VISUAL NOTIFICATION APPLIANCE CIRCUITS. PROVIDE ALL REQUIRED SYNC MODULES. PROVIDE A MULTI -SYNC MODE SLAVE CONNECTION BETWEEN ALL SYNC MODULES. 14. VERIFY ALL FIELD SELECTABLE AUDIBILITY SETTINGS OF NOTIFICATION APPLIANCES WITH FIRE ALARM CONTRACTOR. 15. UPON COMPLETION OF THE FIRE ALARM SYSTEM INSTALLATION AND PROGRAMMING, THE INSTALLING CONTRACTOR SHALL PERFORM FINAL TESTING OF THE ENTIRE SYSTEM, PER ALL APPLICABLE CODES, AND SHALL COORDINATE AND PERFORM A FINAL FIRE ALARM SYSTEM INSPECTION. 16. PROVIDE OFF-SITE MONITORING AS REQUIRED BY THE INTERNATIONAL FIRE CODE, SECTION 907.6.5 AND THE LOCAL AUTHORITY HAVING JURISDICTION. 17. INSTALLING CONTRACTOR SHALL, PHYSICALLY, LABEL ALL INITIATING DEVICES AND NOTIFICATION APPLIANCE CIRCUIT END OF LINE (WHEN WIRING CLASS "B"). THESE LABELS SHALL BE IN PLACE PRIOR TO START-UP AND TESTING. ///// \\\\\� • • JJI /I -I 36" MIN. I-= MANUAL PULL I-5' MAX. STATION O 42"-48" NOTE: MEASUREMENTS SHOWN ARE TO THE /y+E LI1J,`I� CLOSEST POINT OF JJ JJl1�1J/1JJJ111JIJJJJl-l1JJl JJIIJJ_I_ DETECTOR WALL -MOUNTED CEILING MOUNTED SMOKE DETECTOR SMOKE/HEAT DETECTOR i DOOR WIDTH -LESS 3=I 6" MAGNETIC o DOOR HOLDER SIDE WALL FINISHED /FLOOR tt (/i>IIIIIIJJJIJ/IIIIII/IIIII/III m.ezII_IIIJII,II,III,,,, ,,,,JI JJJ// /I//IIIIIIIJIJJIJ/JJJJII/I,,,,,,/JIIII,,,,,IIIIJI/1 FIRE ALARM DEVICE MOUNTING HEIGHTS SCALE: NOT TO SCALE FINISHED WALL Bra Signature Date: 7/30/2018 Fire Protection Engineering Technoly Fire Alarm S ems Cert. No. 1 751 Exp 5/1/2019 00 z 0 a rJ w 0 FOR REVIEW & APPROVAL 2 0 0 1253 S JACKSON ST. SEATTLE, WA 206-328-3288 shop drawings created by: 5794 W.4600 So. Hooper, UT 84315 Office: 801.985.0410 www.unicod.net NBCA 71tin Inc. t DANIA TU ILA 1251 ANDOVER PARK WEST TU =` ILA, WA 98188 CALCULATIONS, DIAGRAMS, AND NOTES DRAWN CRL UNICAD JOB #18461 CHECKED BRADY B. HAWS NICET III 138751 DATE 7/30/2018 REVISION 0 SCALE 1/16"=1'-0" FA -2