PP - 3460 S 148TH ST - KING COUNTY WATER DISTRICT 125 - PERMITS AND PLANS
3460 S 148TH ST ASSOCIATED PERMITS D06-086 M06-051 06-F-248 06-S-221 INSPECTION NUMBER APR 3 U 200? INSPECTION RECORD O- 09(0 Retain a copy with permit 0(4- ! X48 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:\. \'2,S vo„,., Aap,.-..- , ( Type of Inspection: , kraL Address: 34(,b 5 , it erti, Suite #: Co act Person: 4.C.-) Special Instructions: Phone No.: RApproved per applicable codes. ‘,i44. ,}�, Corrections required prior to approval. COMMENTS: 1) A. "113 VC rpS.... r r -A, . 6 cst c-izit iY\ ‘;..0 r Cor e -c &vrs , A, kv.b7\ Scot,_ \r *-41.. AY1 b) Faddc,ess qfrisea, oim \so: s 0 .5., IA"kurs 5'l aax hk% , Wa* 6 CcicsZ is &;k -e* SOD i 5•Ak- s * kVtis Occupancy Type: 0 wA, l 13 ivtimikiks (e,, d)sc$0,.41,. LLvwv.v - tic.,. Sikr;vAckec A.r%3y,fit ii4,als otm'vrtskik10.7t,tc tliFt404 l 3 M1 QS.: ,, Needs Shift Inspection: Sprinklers: y e5 Fire Alarm: .C. , Hood & Duct: Monitor: Gvca�� Pre -Fire: NONE Permits: '?,t, c,A bx. ,l,Qla Occupancy Type: 0 wA, l 13 ivtimikiks (e,, Inspector: At v=viN 51 Date: 41Z-10-1 Hrs.: 115 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy w • permit APR 302007 •o4- o$6 o6-S-ui PERMIT NUM : ERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: wD 12S -so INT Ao Pm r4 . .o(, Type of Inspection: Sfulat urAfilig A} / 5 PizN IC //moil Address: 3'O S . I LIS ST Suite #: ContPerson: lfCo&gy le/1471G Special Instructions: Phone No.: IXApproved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: )/ Q FA FtOAt� 0K — S1 b t4Ac.s Ic 74T' FA X€13 ID oFPi Hood & Duct: N © Con . LT — OIL - Au 6 0402_. -I t r/c o w / 1. -re OVA EX i r Pre -Fire: s l 0 MG -Gk} ' — FA OIL Occupancy Type: "et, gp Covera..Tts P/ SPt2.4 µ 1c. cem - o K. 0/: -1 aacr> / 4#416 elit•G ltt_ ifPioZo tf Needs Shift Inspection: Sprinklers: )/ Fire Alarm: I Hood & Duct: N Monitor: ('Vqa-o set N Pre -Fire: s l Permits: Occupancy Type: "et, Inspector: 9.0/5 /Z Date: 411/44/07 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 TUKWILA FIRE PREVENTION BUREAU 444 Andover Park East, Tukwila, WA 98188 - Phone 206-575-4407 - Fax 206-575-4439 E-mail: tukfdpry@ci.tukwila.wa.us CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing_and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date(' /- U- 67 Permit # Property Address 1L1 4 O { 8f'" S t Suite # City Tukwila Zip Code 7/8 Name of Facility K i vioa (, ,i -y I,Jc ear / Z 5 Occupied as Owner or Representative Phone # Installing Company GuGccXIcwSec J.At Installing Contractor's Address 1M 15 f Ave SCS City 5ec1/4. - Phone # (O6) 6 - 6 51/5 Installer's Name (PRINT) Mr - c -A. (_ox,.3p License and/or Certificate W W E- Rik 9 3Q 6 General Contractor _ Electrical Contractor FACP Equipment Manufacturer S re rv,pw-,_ Model # 1= 5 --g5 This system has been installed, pre -tested and operates in accordance with the standards listed below and was inspected by Z i 1_0 On (date) 4/2 6 /C 7 and includes the devices listed on back. Circle all that apply: NFPA 72, Chapter 1 2 4 5 6 7 and/or IFC SEC 907 NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions Manufacturer's Instructions Other (specify) Tukwila City Ordinance Numbers 2050, 2051 UL Central Station Monitor 776 330 System is monitored by(-cicf l'�i4v1 a( t-/ SIGNED �ir� ��� Date 0/// 26/07 /l System Firmware: Installed version Initial program Installation Checksum Revisions and Reasons Date Date Programmed by EQUIPMENT INSTALLED AND TESTED: Control Panel J of __(_ Manual Station of -5 Smoke Detectors of Heat Detectors of Duct Detectors of A/V Devices of Audio Devices of 24 Visual Devices j of 29 Auto Door Release of Trouble Indictors of Batteries Readings Battery a5.3 8 Generator of HVAC Controls 3 of Fire Alarm Dialer of Monitored by G ttC.tcX i G v Annunciator ( of Make/Model 5 l e-)iy € vV` -3 —.2.G Make/Model 5 iew‘eN• Make/Model 5 i € -Y\ S Fl - /1 Make/Model Make/Model 5 f .5 e*n SC r' Make/Model Make/Model IA) ee.,1 Make/Model l.0\,ee k (o c SIC Make/Model Make/Model Full Load .16 •`f Make/Model Charge 017 Make/Model Sy Make/Model . 3Pc Make/Model ❑ Sprinkler System. (Fire Alarm connections only) Water Flow Sw. r' • of P, Make/Model 4-4TR I -P 5/ EME NS Valve Tamper Sw. 5 of 5 Make/Model F}TR I - 5i e�nne.M S PIV 1 of JMake/Model HTR /- D 5i e. vv -1 evx 5 Elec. Alarm Bell / of I Make/Model W tree I k p Automatic time Delay of Water Flow Alarm seconds. None Installed Do you meet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes V No Test of alarm System on emergency power, satisfactory? Yes v No _ Test Witnessed by Title Date Comments: eddins\Contractors Material & Test Certificate Revised: 10/28/04 TFD FP Form #110 I TUKWILA FIRE DEPARTMENT FIRE PREVENTION BUREAU (206) 575-4407 CORRECTION NOTICE/REINSPECTION FEE BUSINESS NAME: W D MG' - To t+4T Acbakii t DATE: cf (Z!o /07 ADDRESS: 3ifbo S. NS Sr BLDG: SUITE: APT: TYPE OF INSPECTION: dPor INSPECTOR: 9145/2_ BLDG. PERMIT #: CONTACT PERSON: EDCr///Citi it.Ii PFla: 1 •-:Ia7W Y ACTION REQUIRED: b 2 /,lox eDx - DA( o,2-ce.-- NVAiiii grip git-a- DL4,r, atitvervii S" Arriz- (4/ kvex 4,06kav i 0 4.4,04(,,r ,,,ccoAte6- 411- Ore- frp ,e/.6-45. CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY: 416 /01 • A $80.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. FAILURE TO COMPLY may result in the issuance of a criminal citation. Correction Notice Reinspec Fee W -Office Y -File P -Contractor Revised 1/13/06 T.F.D. Form F.P. 100 Norita Deckard From: Sent: To: Subject: Hi Norita, I am requesting District at 3460 permit under. Business Name: Kathleen Onih <kathleenh@valvue.com> Thursday, December 124 2013 12:25 PM Norita Deckard Name & Address Change +r Operation Permit 3460 S 148th St a name and address change for 3460 S 148th1St. Currently the Business name is: Valley View Sewer S 148th St, #100, (P.O. Box 69550. Seattle, 98168). The following is what we would like the operation Water Sewer District Condominium AssociaXion 3460 South 148th Street (P.O. Box 68297, Seattle, 98168) w. The contact for this building will still be the same. Also I will be sending in the renewal application with payment today. Thank you for your help in this matter. Kathleen Onih Finance Officer Valley View Sewer District (206) 242-3236 (206) 242-1527 Fax kathleenhvalvue.com 1 January 24, 2007 City of Tukwila Steven M. Mullet, Mayor Fire Department Nicholas J. Olivas, Fire Chief Val Vue Sewer District P.O. Box 69550 Seattle, Washington 98168 Dear Sir: The existing address for the Water District 125 building (Tax Parcel #0040000850) was 3460 South 148th Street; the address was changed to 3454 South 148th Street. The new building (Tax Parcel #0040000844) will be addressed 3460 South 148th Street with the following suite numbers: Suite #100 - Val Vue Sewer District office Suite #110 - Water District 125 office If you have any questions, please call me at 206-575-4407. Yours truly, Battalion Chief Don Tomaso Fire Marshal DT: ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 GUARDIAN SECURITY Seattle - Tacoma - Poulsbo - Bellingham 1743 First Avenue South Seattle, WA 98134 Tel: 206.622.6545 Fax: 206.341.9928 Water District #125 Administration building 3460 148th St. Tukwila, WA 98168 Fire Alarm System Submittal INDEX 1. Panels Siemens FS -250 Addressable Fire Alarm Control Panel 2. Initiation Devices Siemens Siemens Siemens Siemens HFP-11 HMS -S HTRI-D HTR -R 3. Notification Appliances Wheelock Wheelock Wheelock Wheelock NS-24MCC-FW RSS-24MCCR-FW MB -G 10-24-R RSSWP Addressable Smoke Detector Addressable Manual Pull Station Addressable Dual Input Monitor Addressable Relay Module Ceiling Mount horn/Strobe Ceiling Mount Strobe Exterior Bell Exterior Strobe PROJECT: King County Water Distric 125 Admin Bldg Panel: Seimens FS -250 Date: December 7, 2006 Description Device Battery Calculation Sheet Model Qty Photo Detector HFPO-11 Fireprint Detector HFP-11 Thermal Detector HFPT-11 Remote Lamp -Ceiling RL -HC Remote Lamp -Wall RL -HW Intel Lamp -Ceiling ILED-HC Intel Lamp -Wall ILED-HW Air Duct Housing w/Relay AD -HR Air Duct Housing AD -11P Manual Station -Single Action HMS -S Manual Station -Dual Action HMS -D Manual Station -Metal HMS -M Single Input Monitor Module HTRI-S Dual Input Monitor Module HTRI-D Single Input w/Relay Module HTRI-R Mini Single Monitor Module HTRI-M Conventioanl Zone Module HZM Total Standby Standby Alarm mAl (mA) (mA) Total Alarm mAl Total(A)= 70 Total(B)= 198 0 0 18 0 6 0 0 18 108 0 0 10 0 0 0 18 0 0 0 18 0 0 0 18 0 0 0 18 0 5 0 0 0 0 0 0 18 0 4 10 40 15 60 15 0 15 0 15 0 15 0 10 0 10 0 2 10 20 10 20 1 10 10 10 10 0 18 0 0 0 0 0 0 0 Total(A)= 70 Total(B)= 198 Alan Metzler - FS-250%20Owners%20Manual. •df 42 FS -250 System Power Requirements Does not include NAC power and Releasing Circuit) Device Item Max.(Amps) FS -250 Amps FS -250 Control panel (Includes 1 FS -DLC) 0.190 10.190 Addressable Device Circuit Power # of Devices X 0.0018 Amps Auxiliary Power Outputs * Depends on devices installed FS -MT Municipal Tie Board 0.055 I FS-DACT DACT Board 0.054 FS -REL Releasing Module' 0.050 FS-RU2 Remote LCD Annunciator * 0.085 FS RU2JFS RE8 Serial Relay Unit * 0.032+0.020 A for each relay I FS-SAU2 FS-SAE1 6 Serial Annundator Unit * 0.070+ load of each LED or lamp I Total current requirements Must be less than or equal to 0.75 I ' Maximum module current draw from the system (Does not include the current draw from releasing circuit and open collector.) Auxiliary Power Supply *Connect a PAD -3 auxiliary supply when power requirement calculation indicates that an additional source is required. For further information, refer to Appendix D. Battery Size Calculations For calculation of battery size requirements see Appendix A. 36 FILE COPY FS -250 Battery Calculation Project: King County Water District #125 - Admin Building Date: November 1, 2006 Standby(C) Hours= 24 Module Description Base Panel FS-RDU Remote Annunciator rn FS-DACT FS-RU2 o FS-RE8 FS-SAU2 FS-SAE16 N NAC Circuit 1 U 5 NAC Circuit 2 2 NAC Circuit 3 • NAC Circuit 4 4 Wire Smokes Addressable Devices Miscellaneous Miscellaneous Ala rm(D) Minutes= Battery Capacity -1.2x (AxC)+((.0167xD)xB) divided by 1000 5 Qty Standby (mA) Total Standby Alarm Total Alarm (mA) (mA) (mA) 0 Without Comments Er.. As Noted In Red Per The Attached Letter 1 190 190 190 190 These plans have been reviewed by The Tukwila Fire 1 20 20 85 85 Prevention Bureau for conformance with current city 1 38 38 54 54 ; standards. Acceptance is subject to errors and O 32 0 192 0 omissions which do not authorize violations of adopted O 0 0 160 0 stewards and ordinances. The responsibility for the O 18 0 70 0 adequacy of design rests totally with the designer. O 5 0 0 0 Additions, deletions or revisions iv these drawings atter this date will void this€,acceptance and will require a resubmittal of revised drawings for subsequent app oval. 1 0 0 0 0 0 0 0 0 0 1 0 O 0 0 0 Total (A)= 0 0 0 0 1431 831 866 0 0 0 O 0 70 0 O 0 O 0 318 Total(B)= 9.52 10 Amp Hour Provided FIffE 4LARRM =/\NEL E3ATTEI,R t' CALCULATION Notification Appliance Circuit Detail PROJECT: King County Water District #125 Date: November 27, 2006 CIRCUIT: S1 QTY 3 4 Device Type RSS-24MCC @ 15cd AS-24MCC @ 15cd A 24.MICC @ 30cd DEVICES= 14 M3' 10-1`f"rz. CIRCUIT: S2 QTY Device Type 4 AS-24MCC @ 15cd 1 AS-24MCC @ 75cd 2 ASWP DEVICES= 7 CIRCUIT: S3 QTY 2 1 3 1 1 Device Type RSS-24MCC @ 15cd RSS-24MCC @ 30cd AS-24MCC @ 15cd AS-24MCC @ 30cd AS-24MCC @ 95cd DEVICES= 8 Alarm Current 65 80 122 155 85 1431 831 866 0 0 0 198 0 0 3655 CURRENT TOTAL= 3128 Final acceptance is subject to field test and Inspect' The Tukwila Fire Prevention Bureau. Date: -7-°5a By: / -1-ysfct It -£g "e key} • ke?40K . Alarm Total 195 320 366 465 85 TOTAL mA= 1431 Wire Size Wire Length Volts @ EOL Circuit Total 14 150 22.630533 AJarm Current 80 201 155 TOTAL mA= Alarm Total 320 201 310 831 14311 Wire Size Wire Length Volts @ EOL Circuit Total Alarm Current 65 105 80 122 269 TOTAL mA= 14 400 21.8792881 Alarm Total Wire Size 130 105 240 122 269 866 14 831 Wire Length Volts @ EOL Circuit Total 325 22.204349[ - 8661 NOTIFICATION APPLIANCE CIRCUIT DETAIL CALCULATIONS Shst-i (( loe.kosii- devicce rectIce✓ 717/ci.) 4 i ey 0. Set)re V h a eivvf 01 e4evto rs -Cov. )- t/A C. 511,x%- (owh o s -t 44„,ro i r. ' n by NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing -of any Fire Alarm and Detection Systems. Failure of test Will result in a e-anction Fee and i ' ion of the 6731, fUKWILA FIRE DEPARTMEN'L Please call: 575.4407, and give this job No. dF"a`i and exact address for shut• °own or restoration approval!: 1. ALL WALL -MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 80" TO BOTTOM. NFPA 72, 2002 EDITION, ALLOWS 80"-96" FOR VISUAL DEVICES (CH. 7.5.4) AND REQUIRES A MINIMUM OF 90" TO TOP FOR AUDIBLE DEVICES . OR 6" FROM CEILING, WHICHEVER IS LOWER (CH. 7.4.6.1). FOR SLEEPING AREAS GREATER THAN 16' (LINEAR) VISIBLE NOTIFICATION SHALL BE WITHIN 16' OF PILLOW AND GREATER THAN OR EQUAL TO 24" FROM CEILING TO TOP OF LENS FOR 110cd (CH. 7.5.4.4) 2. ALL EQUIPMENT SHALL BE U.L. AND _C.S.F.M. LISTED. 3. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHOOTING, ETC. 4. DO NOT DEVIATE FROM CIRCUITS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS (206)622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC., THAT ARE A RESULT OF DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 5. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER THAN 3 FEET (900mm) FROM AN AIR SUPPLY DIFFUSER. 6. ALL DUCT SMOKE DETECTORS SHALL BE MOUNTED BY THE MECHANICAL CONTRACTOR. DUCT SMOKE DETECTORS EXPOSED TO THE WEATHER SHALL BE WEATHER PROTECTED BY THE MECHANICAL CONTRACTOR. ALL AIR VELOCITY TESTING SHALL BE PERFORMED BY THE MECHANICAL CONTRACTOR. 7. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION. 8. ALL FIRE ALARM DEVICE BACKBOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTION BOXES, AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION. SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 9. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH APPROVED SMOKE. 10. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE CIRCUITS. 11. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED -THROUGH DEVICES. ALL SPLICED WIRE POSSESING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. 12. POINT AND COMMON ANNUNCIATION AND T -TAPPING (EXCEPT SLC LOOP) ARE PROHIBITED. 13. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER. 14. ALL FLOW SWITCHES SHALL BE 2 WIRE WITH NON -ELECTRONIC RETARD TYPE SIMILAR TO THE SYSTEM SENSOR MODEL "WFD SERIES" ONLY. 15. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 16. SYSTEM SHALL BE FURNISHED AND INSTALLED BY A SIEMENS AFFILIATE AND AUTHORIZED PYROTRONICS DISTRIBUTOR. 17. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE UL LISTED (UUJS). 18. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS 19. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ 20. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S. TECHNICIANS 21. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE 'KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. FIELD TECHNICIANS 22. DUCT SMOKE DETECTORS SHALL BE MOUNTED WITHIN 5' OF MOTORIZED FIRE/SMOKE DAMPERS PER IMC 2003. FIRE/SMOKE DAMPERS PROVIDED BY DIVISION 15, INSTALLED BY DIVISION 15, WIRED BY DIVISION 16. QUANTITY SYMBOL DESCRIPTION 2 5 MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT [FACP FIRE ALARM CONTROL PANEL FS -250 SIEMENS PROVIDED 66" A.F.F. TO TOP PHOTOELECTRIC SMOKE P DETECTOR WITH BASE HFP-11 SIEMENS 4" SQUARE CEILING 1 -GANG RING F MANUAL PULL STATION HMS -S SIEMENS 4" SQUARE DEEP BOX 48" A.F.F. TO HANDLE D DUAL MONITOR MODULE HTRI-D SIEMENS 4" SQUARE DEEP BOX VERIFY r" 1 RORM ELAY C HTRI-R SIEMENS 4" SQUARE DEEP BOX VERIFY 'DS PHOTOELECTRIC DUCT SMOKE DETECTOR AD -HR SIEMENS SELF CONTAINED VERIFY FS WATER FLOW SWITCH BY DIV 15 BY DIV 15 BY DIV 15 VERIFY T VALVE POSITION SWITCH BY DIV 15 BY DIV 15 BY DIV 15 VERIFY Lyj POST INDICATOR VALVE BY DIV 15 BY DIV 15 BY DIV 15 VERIFY FIRE ALARM HORN/STROBE NS-24MCC-FW WHEELOCK 4" SQUARE DEEP BOX CEILING FIRE ALARM STROBE RSS-24MCCR-FW WHEELOCK 4" SQUARE DEEP BOX CELING OFIRE ALARM WP EXTERIOR BELL NS-24MCC-FW WHEELOCK 4" SQUARE DEEP BOX CEILING FIRE ALARM WP EXTERIOR STROBE RSS-24MCCR-FW WHEELOCK 4" SQUARE DEEP BOX CELING Op FIRE/SMOKE DAMPER BY DIV 15 BY DIV 15 BY DIV 15 VERIFY LEGEND WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION NUMBER OF SYMBOL DESCRIPTION CONDUCTORS SIZE TYPE COLOR CODE S NOTIFICATION APPLIANCE CIRCUIT - FEED TWO #14 FPL/FPLR RED + BLK - S' NOTIFICATION APPLIANCE CIRCUIT - RETURN TWO #14 FPL/FPLR RED + BLK - D SIGNALING LINE CIRCUIT TWO #18 FPL/FPLR RED + BLK - P POWER - 24VDC TWO #14 FPL/FPLR RED + BLK - A RS -485 ANNUNCIATOR COMMUNICATION TWO #16 FPL/FPLR RED + BLK - FSD FIRE/SMOKE DAMPER CIRCUIT TWO+GROUND #12 THHN/THWN AS REQ. CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #15 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. i CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH '3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. GENERAL NOTES DATA IN FROM FACP I(_} 12OVAC BY OTHERS 0 EARTH GROUND 24VDC FROM FACP 0 0 0 N/0 TRI -R C MODULE N/C 8 7 6 0 DPDT CONTACTS 10A RESISTIVE e 115 VAC • 7 TO SMOKE DAMPER 0 NC C ND N3 ®® C 0 NO LED MR -101 0 18 24 115 230 0 S vIOKE DA (N 101 ;\N J HVS-S ACTUATION D TO NEXT ADDRESSABLE DEVICE FROM INITIATING CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE EARTH GROUND VANUAL STATION FROM MXL PANEL OR PREVIOUS ADDRESSABLE C DEVICE TO NEXT ADDRESSABLE DEVICE END OF LINE DEVICE SUPERVISED SWITCH SEE NOTE 1 AND 2 EARTH GROUND - NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - 27 VDC 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD AND/OR OPEN FOR AT LEAST .25 SEC. TO DETECTION. CLOSED GUARANTEE 2 3 4 5 0 0 0 8 7 6 NOT USED �S2 SUPERVISED SWITCH SEE NOTE 1 AND 2 TYPICAL WIRING FOR HTRI-D MODULE JUNCTION BOX MOUNTED ON CEILING SLAB SMOKE DETECTOR JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT TO NEXT DEVICE SUSPENDED ILLUMINATED CEILING CEILING SMOKE IDETECTOII 1DETAIL TO SIGNALING LINE CIRCUIT OF CERBERUS PYROTRONICS COMPATIBLE CONTROL UNIT DETECTOR BASE' MODEL DB -11 OR MODEL DB -3 WITH DB-ADPT OPTIONAL REMOTE ALARM INDICATOR MODELS RLI-1/RLI-2 DETECTOR BASE FOR USE WITH FP -II SMOKE DETECTOR AND FPT-11 HEAT DETECTOR HFP-11 /HFPT-11 DETECTOR WIRING CEILING TILE CEILING STROBE TYPICAL DEVICE LAYOUT BOX SUPPORT BRIDGE 4S DEEP BOX W/ 4S EXTENSION WIRE DESIGNATIONS NS-24MCC-FW HORN/STROBE RSS-24MCCR-FW Copyright 2002 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 (/) Z rn W w U) W Lu IREV. BY: 1 V) mm 0 V) 0 DESCRIPTION SUBNA ITTEO FOR APPROVALI 1 I 4 W O. Z 0 V) W r DATE , CD CD s\ c N s <a«< N UW 0 CC (i)o Noy o a m IO) < W 17_ F - o03 w aNrg . () _ 2 z� OF - z 4 ° w U cc C� SCALE: AS NOTED IL DRAWN BY: D. SAGRELIUS DESIGNED BY: D. SAGRELIUS DATE: 11/01/0 6 BACKROUND PLAN PROVIDED BY: EHS ELECTRIC JOB NUMBER: 541 1 j SHEET FA -01» M:\iirawings\Krq Cour* Water J strict -i25\FAJ7wg5\FA-02 dwq, II/ 27/ 2006 2:03:0I PM, f?MG FR 655 INC. STORAGE__ A-20 165 SF SERVER / PLOTTER AREA A-08 101 SF GEN. MANAGER A-07 156 SF WK STATION A-06 98 SF ADMIN. SEC. A-05 134 SF ESD RE UNISEX-ADA-SHW r S1-6 B-21 S1- ICTRICAL ==, C-13 23 SF 9SF 0_ I ACP D DW JAN. S,S' 15 t f S2\4 \15c s2= MAIL AREA A-21 ENTRY 'A' e 225 SF HALL A-22 15cd- -- S1 Ocd 1--8 61 SF cd CPC LU 0 H/TWIINI (A-3) \ 99 F 2 PANTRY C-08 L"OITRY'B' c-1 81 3-2 61 STOR. B-17 50 SF D o 13 SF D S 0 DS FSD FS D -- STORAGE C-05 14 SF STORAGE S,S' o TO=_=-R IN ELCTRI ROOM `\ FSD p HALL A-09 WORK AREA A-13 110 SF FIRE VAULT A-17 94 SF REF -- OFFICE SUPPLIES A-12 71 SF INSPECTOR A-11 72 SF 30cd S1-10 INSPECTOR A-10 73 SF S2-2 MEETING ROOM (A-3) C-04 931 SF HALL A-14 PAYROLL A-04 122 SF 30cd S1-11 S 15cd S1-13 CONTRACTOR/ MAP RM A-15 149 SF FN S FSD 30cd S3-8 WK STATION A-03 107 SF RECEPTION A-02 85 SF TI 15cd S1-12 LOBBY A-01 181 SF FSD FACPC LEC. CLST B-22 28 SF FIRE VAULT B-13 94 SF / COATS B-23 9 SF "_ 30cd S3-4 CONF./ADJOURNMENT 3-08 322 SF _ 4 1 CONTRACTOR/ MAP RM B-05 130 SF S 15cd S3-6 MAIN LOBBY C-01 256 SF H. A 4 MF SCALE — 1 /4" = 1' NORTH LOBBY 3-01 135 SF RECEPTION 1. B-02 66 SF 14, fr HALL 8-15 132 SF 15cd S3-2 MAII../WORK RM B-12 158SF GENERAL MGR. B-16 150 SF 15cd S3-3 HA B-1 16' 0 SF 1 IF WORKFILES n-04 280 SFS 95cd S3-5 WORKSTATION 3-03 151 SF WORK STATION 3-14 77 SF OFFICE MGR. B-11 150 SF SERVER/AUDITOR ASSIST. OFFICE MGR. B-06 120 SF Copyright 2002 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 TEL. (206) 622-6545 U) 0 W w C/) w J W REV. BY: mm 0 0 DESCRIPTION SUBMITTED FOR APPROVAL -I I 4 lY W 1 VI z 0 V) > hi DATE CD ON 9 <aaaa (co N �U Lc°w Er" rfiro d vi r fA 0 CO ° II 0 03J z Q o �3 Q erg 2(Ci 94t clinx o° 111 U 0 U.SCALE: AS NOTED 0. DRAWN BY: D. SAGRELIUS DESIGNED BY: D. SAGRELIUS DATE: 11/01/0 6 BACKROUND PLAN PROVIDED BY: EHS ELECTRIC •OB NUMBER: 54 1 1 SHEET FA -02 3460 S 148TH ST ASSOCIATED PERMITS D06-086 M06-051 06-F-248 06-S-221 INSPECTION NUMBER APR 3 U 200? INSPECTION RECORD O- 09(0 Retain a copy with permit 0(4- ! X48 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:\. \'2,S vo„,., Aap,.-..- , ( Type of Inspection: , kraL Address: 34(,b 5 , it erti, Suite #: Co act Person: 4.C.-) Special Instructions: Phone No.: RApproved per applicable codes. ‘,i44. ,}�, Corrections required prior to approval. COMMENTS: 1) A. "113 VC rpS.... r r -A, . 6 cst c-izit iY\ ‘;..0 r Cor e -c &vrs , A, kv.b7\ Scot,_ \r *-41.. AY1 b) Faddc,ess qfrisea, oim \so: s 0 .5., IA"kurs 5'l aax hk% , Wa* 6 CcicsZ is &;k -e* SOD i 5•Ak- s * kVtis Occupancy Type: 0 wA, l 13 ivtimikiks (e,, d)sc$0,.41,. LLvwv.v - tic.,. Sikr;vAckec A.r%3y,fit ii4,als otm'vrtskik10.7t,tc tliFt404 l 3 M1 QS.: ,, Needs Shift Inspection: Sprinklers: y e5 Fire Alarm: .C. , Hood & Duct: Monitor: Gvca�� Pre -Fire: NONE Permits: '?,t, c,A bx. ,l,Qla Occupancy Type: 0 wA, l 13 ivtimikiks (e,, Inspector: At v=viN 51 Date: 41Z-10-1 Hrs.: 115 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy w • permit APR 302007 •o4- o$6 o6-S-ui PERMIT NUM : ERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: wD 12S -so INT Ao Pm r4 . .o(, Type of Inspection: Sfulat urAfilig A} / 5 PizN IC //moil Address: 3'O S . I LIS ST Suite #: ContPerson: lfCo&gy le/1471G Special Instructions: Phone No.: IXApproved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: )/ Q FA FtOAt� 0K — S1 b t4Ac.s Ic 74T' FA X€13 ID oFPi Hood & Duct: N © Con . LT — OIL - Au 6 0402_. -I t r/c o w / 1. -re OVA EX i r Pre -Fire: s l 0 MG -Gk} ' — FA OIL Occupancy Type: "et, gp Covera..Tts P/ SPt2.4 µ 1c. cem - o K. 0/: -1 aacr> / 4#416 elit•G ltt_ ifPioZo tf Needs Shift Inspection: Sprinklers: )/ Fire Alarm: I Hood & Duct: N Monitor: ('Vqa-o set N Pre -Fire: s l Permits: Occupancy Type: "et, Inspector: 9.0/5 /Z Date: 411/44/07 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 TUKWILA FIRE PREVENTION BUREAU 444 Andover Park East, Tukwila, WA 98188 - Phone 206-575-4407 - Fax 206-575-4439 E-mail: tukfdpry@ci.tukwila.wa.us CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing_and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date(' /- U- 67 Permit # Property Address 1L1 4 O { 8f'" S t Suite # City Tukwila Zip Code 7/8 Name of Facility K i vioa (, ,i -y I,Jc ear / Z 5 Occupied as Owner or Representative Phone # Installing Company GuGccXIcwSec J.At Installing Contractor's Address 1M 15 f Ave SCS City 5ec1/4. - Phone # (O6) 6 - 6 51/5 Installer's Name (PRINT) Mr - c -A. (_ox,.3p License and/or Certificate W W E- Rik 9 3Q 6 General Contractor _ Electrical Contractor FACP Equipment Manufacturer S re rv,pw-,_ Model # 1= 5 --g5 This system has been installed, pre -tested and operates in accordance with the standards listed below and was inspected by Z i 1_0 On (date) 4/2 6 /C 7 and includes the devices listed on back. Circle all that apply: NFPA 72, Chapter 1 2 4 5 6 7 and/or IFC SEC 907 NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions Manufacturer's Instructions Other (specify) Tukwila City Ordinance Numbers 2050, 2051 UL Central Station Monitor 776 330 System is monitored by(-cicf l'�i4v1 a( t-/ SIGNED �ir� ��� Date 0/// 26/07 /l System Firmware: Installed version Initial program Installation Checksum Revisions and Reasons Date Date Programmed by EQUIPMENT INSTALLED AND TESTED: Control Panel J of __(_ Manual Station of -5 Smoke Detectors of Heat Detectors of Duct Detectors of A/V Devices of Audio Devices of 24 Visual Devices j of 29 Auto Door Release of Trouble Indictors of Batteries Readings Battery a5.3 8 Generator of HVAC Controls 3 of Fire Alarm Dialer of Monitored by G ttC.tcX i G v Annunciator ( of Make/Model 5 l e-)iy € vV` -3 —.2.G Make/Model 5 iew‘eN• Make/Model 5 i € -Y\ S Fl - /1 Make/Model Make/Model 5 f .5 e*n SC r' Make/Model Make/Model IA) ee.,1 Make/Model l.0\,ee k (o c SIC Make/Model Make/Model Full Load .16 •`f Make/Model Charge 017 Make/Model Sy Make/Model . 3Pc Make/Model ❑ Sprinkler System. (Fire Alarm connections only) Water Flow Sw. r' • of P, Make/Model 4-4TR I -P 5/ EME NS Valve Tamper Sw. 5 of 5 Make/Model F}TR I - 5i e�nne.M S PIV 1 of JMake/Model HTR /- D 5i e. vv -1 evx 5 Elec. Alarm Bell / of I Make/Model W tree I k p Automatic time Delay of Water Flow Alarm seconds. None Installed Do you meet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes V No Test of alarm System on emergency power, satisfactory? Yes v No _ Test Witnessed by Title Date Comments: eddins\Contractors Material & Test Certificate Revised: 10/28/04 TFD FP Form #110 I TUKWILA FIRE DEPARTMENT FIRE PREVENTION BUREAU (206) 575-4407 CORRECTION NOTICE/REINSPECTION FEE BUSINESS NAME: W D MG' - To t+4T Acbakii t DATE: cf (Z!o /07 ADDRESS: 3ifbo S. NS Sr BLDG: SUITE: APT: TYPE OF INSPECTION: dPor INSPECTOR: 9145/2_ BLDG. PERMIT #: CONTACT PERSON: EDCr///Citi it.Ii PFla: 1 •-:Ia7W Y ACTION REQUIRED: b 2 /,lox eDx - DA( o,2-ce.-- NVAiiii grip git-a- DL4,r, atitvervii S" Arriz- (4/ kvex 4,06kav i 0 4.4,04(,,r ,,,ccoAte6- 411- Ore- frp ,e/.6-45. CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY: 416 /01 • A $80.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. FAILURE TO COMPLY may result in the issuance of a criminal citation. Correction Notice Reinspec Fee W -Office Y -File P -Contractor Revised 1/13/06 T.F.D. Form F.P. 100 Norita Deckard From: Sent: To: Subject: Hi Norita, I am requesting District at 3460 permit under. Business Name: Kathleen Onih <kathleenh@valvue.com> Thursday, December 124 2013 12:25 PM Norita Deckard Name & Address Change +r Operation Permit 3460 S 148th St a name and address change for 3460 S 148th1St. Currently the Business name is: Valley View Sewer S 148th St, #100, (P.O. Box 69550. Seattle, 98168). The following is what we would like the operation Water Sewer District Condominium AssociaXion 3460 South 148th Street (P.O. Box 68297, Seattle, 98168) w. The contact for this building will still be the same. Also I will be sending in the renewal application with payment today. Thank you for your help in this matter. Kathleen Onih Finance Officer Valley View Sewer District (206) 242-3236 (206) 242-1527 Fax kathleenhvalvue.com 1 January 24, 2007 City of Tukwila Steven M. Mullet, Mayor Fire Department Nicholas J. Olivas, Fire Chief Val Vue Sewer District P.O. Box 69550 Seattle, Washington 98168 Dear Sir: The existing address for the Water District 125 building (Tax Parcel #0040000850) was 3460 South 148th Street; the address was changed to 3454 South 148th Street. The new building (Tax Parcel #0040000844) will be addressed 3460 South 148th Street with the following suite numbers: Suite #100 - Val Vue Sewer District office Suite #110 - Water District 125 office If you have any questions, please call me at 206-575-4407. Yours truly, Battalion Chief Don Tomaso Fire Marshal DT: ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 GUARDIAN SECURITY Seattle - Tacoma - Poulsbo - Bellingham 1743 First Avenue South Seattle, WA 98134 Tel: 206.622.6545 Fax: 206.341.9928 Water District #125 Administration building 3460 148th St. Tukwila, WA 98168 Fire Alarm System Submittal INDEX 1. Panels Siemens FS -250 Addressable Fire Alarm Control Panel 2. Initiation Devices Siemens Siemens Siemens Siemens HFP-11 HMS -S HTRI-D HTR -R 3. Notification Appliances Wheelock Wheelock Wheelock Wheelock NS-24MCC-FW RSS-24MCCR-FW MB -G 10-24-R RSSWP Addressable Smoke Detector Addressable Manual Pull Station Addressable Dual Input Monitor Addressable Relay Module Ceiling Mount horn/Strobe Ceiling Mount Strobe Exterior Bell Exterior Strobe PROJECT: King County Water Distric 125 Admin Bldg Panel: Seimens FS -250 Date: December 7, 2006 Description Device Battery Calculation Sheet Model Qty Photo Detector HFPO-11 Fireprint Detector HFP-11 Thermal Detector HFPT-11 Remote Lamp -Ceiling RL -HC Remote Lamp -Wall RL -HW Intel Lamp -Ceiling ILED-HC Intel Lamp -Wall ILED-HW Air Duct Housing w/Relay AD -HR Air Duct Housing AD -11P Manual Station -Single Action HMS -S Manual Station -Dual Action HMS -D Manual Station -Metal HMS -M Single Input Monitor Module HTRI-S Dual Input Monitor Module HTRI-D Single Input w/Relay Module HTRI-R Mini Single Monitor Module HTRI-M Conventioanl Zone Module HZM Total Standby Standby Alarm mAl (mA) (mA) Total Alarm mAl Total(A)= 70 Total(B)= 198 0 0 18 0 6 0 0 18 108 0 0 10 0 0 0 18 0 0 0 18 0 0 0 18 0 0 0 18 0 5 0 0 0 0 0 0 18 0 4 10 40 15 60 15 0 15 0 15 0 15 0 10 0 10 0 2 10 20 10 20 1 10 10 10 10 0 18 0 0 0 0 0 0 0 Total(A)= 70 Total(B)= 198 Alan Metzler - FS-250%20Owners%20Manual. •df 42 FS -250 System Power Requirements Does not include NAC power and Releasing Circuit) Device Item Max.(Amps) FS -250 Amps FS -250 Control panel (Includes 1 FS -DLC) 0.190 10.190 Addressable Device Circuit Power # of Devices X 0.0018 Amps Auxiliary Power Outputs * Depends on devices installed FS -MT Municipal Tie Board 0.055 I FS-DACT DACT Board 0.054 FS -REL Releasing Module' 0.050 FS-RU2 Remote LCD Annunciator * 0.085 FS RU2JFS RE8 Serial Relay Unit * 0.032+0.020 A for each relay I FS-SAU2 FS-SAE1 6 Serial Annundator Unit * 0.070+ load of each LED or lamp I Total current requirements Must be less than or equal to 0.75 I ' Maximum module current draw from the system (Does not include the current draw from releasing circuit and open collector.) Auxiliary Power Supply *Connect a PAD -3 auxiliary supply when power requirement calculation indicates that an additional source is required. For further information, refer to Appendix D. Battery Size Calculations For calculation of battery size requirements see Appendix A. 36 FILE COPY FS -250 Battery Calculation Project: King County Water District #125 - Admin Building Date: November 1, 2006 Standby(C) Hours= 24 Module Description Base Panel FS-RDU Remote Annunciator rn FS-DACT FS-RU2 o FS-RE8 FS-SAU2 FS-SAE16 N NAC Circuit 1 U 5 NAC Circuit 2 2 NAC Circuit 3 • NAC Circuit 4 4 Wire Smokes Addressable Devices Miscellaneous Miscellaneous Ala rm(D) Minutes= Battery Capacity -1.2x (AxC)+((.0167xD)xB) divided by 1000 5 Qty Standby (mA) Total Standby Alarm Total Alarm (mA) (mA) (mA) 0 Without Comments Er.. As Noted In Red Per The Attached Letter 1 190 190 190 190 These plans have been reviewed by The Tukwila Fire 1 20 20 85 85 Prevention Bureau for conformance with current city 1 38 38 54 54 ; standards. Acceptance is subject to errors and O 32 0 192 0 omissions which do not authorize violations of adopted O 0 0 160 0 stewards and ordinances. The responsibility for the O 18 0 70 0 adequacy of design rests totally with the designer. O 5 0 0 0 Additions, deletions or revisions iv these drawings atter this date will void this€,acceptance and will require a resubmittal of revised drawings for subsequent app oval. 1 0 0 0 0 0 0 0 0 0 1 0 O 0 0 0 Total (A)= 0 0 0 0 1431 831 866 0 0 0 O 0 70 0 O 0 O 0 318 Total(B)= 9.52 10 Amp Hour Provided FIffE 4LARRM =/\NEL E3ATTEI,R t' CALCULATION Notification Appliance Circuit Detail PROJECT: King County Water District #125 Date: November 27, 2006 CIRCUIT: S1 QTY 3 4 Device Type RSS-24MCC @ 15cd AS-24MCC @ 15cd A 24.MICC @ 30cd DEVICES= 14 M3' 10-1`f"rz. CIRCUIT: S2 QTY Device Type 4 AS-24MCC @ 15cd 1 AS-24MCC @ 75cd 2 ASWP DEVICES= 7 CIRCUIT: S3 QTY 2 1 3 1 1 Device Type RSS-24MCC @ 15cd RSS-24MCC @ 30cd AS-24MCC @ 15cd AS-24MCC @ 30cd AS-24MCC @ 95cd DEVICES= 8 Alarm Current 65 80 122 155 85 1431 831 866 0 0 0 198 0 0 3655 CURRENT TOTAL= 3128 Final acceptance is subject to field test and Inspect' The Tukwila Fire Prevention Bureau. Date: -7-°5a By: / -1-ysfct It -£g "e key} • ke?40K . Alarm Total 195 320 366 465 85 TOTAL mA= 1431 Wire Size Wire Length Volts @ EOL Circuit Total 14 150 22.630533 AJarm Current 80 201 155 TOTAL mA= Alarm Total 320 201 310 831 14311 Wire Size Wire Length Volts @ EOL Circuit Total Alarm Current 65 105 80 122 269 TOTAL mA= 14 400 21.8792881 Alarm Total Wire Size 130 105 240 122 269 866 14 831 Wire Length Volts @ EOL Circuit Total 325 22.204349[ - 8661 NOTIFICATION APPLIANCE CIRCUIT DETAIL CALCULATIONS Shst-i (( loe.kosii- devicce rectIce✓ 717/ci.) 4 i ey 0. Set)re V h a eivvf 01 e4evto rs -Cov. )- t/A C. 511,x%- (owh o s -t 44„,ro i r. ' n by NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing -of any Fire Alarm and Detection Systems. Failure of test Will result in a e-anction Fee and i ' ion of the 6731, fUKWILA FIRE DEPARTMEN'L Please call: 575.4407, and give this job No. dF"a`i and exact address for shut• °own or restoration approval!: 1. ALL WALL -MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 80" TO BOTTOM. NFPA 72, 2002 EDITION, ALLOWS 80"-96" FOR VISUAL DEVICES (CH. 7.5.4) AND REQUIRES A MINIMUM OF 90" TO TOP FOR AUDIBLE DEVICES . OR 6" FROM CEILING, WHICHEVER IS LOWER (CH. 7.4.6.1). FOR SLEEPING AREAS GREATER THAN 16' (LINEAR) VISIBLE NOTIFICATION SHALL BE WITHIN 16' OF PILLOW AND GREATER THAN OR EQUAL TO 24" FROM CEILING TO TOP OF LENS FOR 110cd (CH. 7.5.4.4) 2. ALL EQUIPMENT SHALL BE U.L. AND _C.S.F.M. LISTED. 3. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHOOTING, ETC. 4. DO NOT DEVIATE FROM CIRCUITS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS (206)622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC., THAT ARE A RESULT OF DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 5. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER THAN 3 FEET (900mm) FROM AN AIR SUPPLY DIFFUSER. 6. ALL DUCT SMOKE DETECTORS SHALL BE MOUNTED BY THE MECHANICAL CONTRACTOR. DUCT SMOKE DETECTORS EXPOSED TO THE WEATHER SHALL BE WEATHER PROTECTED BY THE MECHANICAL CONTRACTOR. ALL AIR VELOCITY TESTING SHALL BE PERFORMED BY THE MECHANICAL CONTRACTOR. 7. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION. 8. ALL FIRE ALARM DEVICE BACKBOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTION BOXES, AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION. SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 9. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH APPROVED SMOKE. 10. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE CIRCUITS. 11. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED -THROUGH DEVICES. ALL SPLICED WIRE POSSESING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. 12. POINT AND COMMON ANNUNCIATION AND T -TAPPING (EXCEPT SLC LOOP) ARE PROHIBITED. 13. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER. 14. ALL FLOW SWITCHES SHALL BE 2 WIRE WITH NON -ELECTRONIC RETARD TYPE SIMILAR TO THE SYSTEM SENSOR MODEL "WFD SERIES" ONLY. 15. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 16. SYSTEM SHALL BE FURNISHED AND INSTALLED BY A SIEMENS AFFILIATE AND AUTHORIZED PYROTRONICS DISTRIBUTOR. 17. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE UL LISTED (UUJS). 18. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS 19. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ 20. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S. TECHNICIANS 21. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE 'KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. FIELD TECHNICIANS 22. DUCT SMOKE DETECTORS SHALL BE MOUNTED WITHIN 5' OF MOTORIZED FIRE/SMOKE DAMPERS PER IMC 2003. FIRE/SMOKE DAMPERS PROVIDED BY DIVISION 15, INSTALLED BY DIVISION 15, WIRED BY DIVISION 16. QUANTITY SYMBOL DESCRIPTION 2 5 MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT [FACP FIRE ALARM CONTROL PANEL FS -250 SIEMENS PROVIDED 66" A.F.F. TO TOP PHOTOELECTRIC SMOKE P DETECTOR WITH BASE HFP-11 SIEMENS 4" SQUARE CEILING 1 -GANG RING F MANUAL PULL STATION HMS -S SIEMENS 4" SQUARE DEEP BOX 48" A.F.F. TO HANDLE D DUAL MONITOR MODULE HTRI-D SIEMENS 4" SQUARE DEEP BOX VERIFY r" 1 RORM ELAY C HTRI-R SIEMENS 4" SQUARE DEEP BOX VERIFY 'DS PHOTOELECTRIC DUCT SMOKE DETECTOR AD -HR SIEMENS SELF CONTAINED VERIFY FS WATER FLOW SWITCH BY DIV 15 BY DIV 15 BY DIV 15 VERIFY T VALVE POSITION SWITCH BY DIV 15 BY DIV 15 BY DIV 15 VERIFY Lyj POST INDICATOR VALVE BY DIV 15 BY DIV 15 BY DIV 15 VERIFY FIRE ALARM HORN/STROBE NS-24MCC-FW WHEELOCK 4" SQUARE DEEP BOX CEILING FIRE ALARM STROBE RSS-24MCCR-FW WHEELOCK 4" SQUARE DEEP BOX CELING OFIRE ALARM WP EXTERIOR BELL NS-24MCC-FW WHEELOCK 4" SQUARE DEEP BOX CEILING FIRE ALARM WP EXTERIOR STROBE RSS-24MCCR-FW WHEELOCK 4" SQUARE DEEP BOX CELING Op FIRE/SMOKE DAMPER BY DIV 15 BY DIV 15 BY DIV 15 VERIFY LEGEND WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION NUMBER OF SYMBOL DESCRIPTION CONDUCTORS SIZE TYPE COLOR CODE S NOTIFICATION APPLIANCE CIRCUIT - FEED TWO #14 FPL/FPLR RED + BLK - S' NOTIFICATION APPLIANCE CIRCUIT - RETURN TWO #14 FPL/FPLR RED + BLK - D SIGNALING LINE CIRCUIT TWO #18 FPL/FPLR RED + BLK - P POWER - 24VDC TWO #14 FPL/FPLR RED + BLK - A RS -485 ANNUNCIATOR COMMUNICATION TWO #16 FPL/FPLR RED + BLK - FSD FIRE/SMOKE DAMPER CIRCUIT TWO+GROUND #12 THHN/THWN AS REQ. CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #15 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. i CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH '3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. GENERAL NOTES DATA IN FROM FACP I(_} 12OVAC BY OTHERS 0 EARTH GROUND 24VDC FROM FACP 0 0 0 N/0 TRI -R C MODULE N/C 8 7 6 0 DPDT CONTACTS 10A RESISTIVE e 115 VAC • 7 TO SMOKE DAMPER 0 NC C ND N3 ®® C 0 NO LED MR -101 0 18 24 115 230 0 S vIOKE DA (N 101 ;\N J HVS-S ACTUATION D TO NEXT ADDRESSABLE DEVICE FROM INITIATING CONTROL PANEL OR PREVIOUS ADDRESSABLE DEVICE EARTH GROUND VANUAL STATION FROM MXL PANEL OR PREVIOUS ADDRESSABLE C DEVICE TO NEXT ADDRESSABLE DEVICE END OF LINE DEVICE SUPERVISED SWITCH SEE NOTE 1 AND 2 EARTH GROUND - NOTE 1: VOLTAGE MAX. - CURRENT MAX. - CONT. RES. MAX. - MAX. CABLE LENGTH - C (LINE TO LINE) - C (LINE TO SHIELD) - MAX. LINE SIZE - MIN. LINE SIZE - 27 VDC 10 OHMS 200 FT. (18 AWG) 0.02uF 0.04uF 14 AWG 18 AWG NOTE 2: ALL SUPERVISED SWITCHES MUST BE HELD AND/OR OPEN FOR AT LEAST .25 SEC. TO DETECTION. CLOSED GUARANTEE 2 3 4 5 0 0 0 8 7 6 NOT USED �S2 SUPERVISED SWITCH SEE NOTE 1 AND 2 TYPICAL WIRING FOR HTRI-D MODULE JUNCTION BOX MOUNTED ON CEILING SLAB SMOKE DETECTOR JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT TO NEXT DEVICE SUSPENDED ILLUMINATED CEILING CEILING SMOKE IDETECTOII 1DETAIL TO SIGNALING LINE CIRCUIT OF CERBERUS PYROTRONICS COMPATIBLE CONTROL UNIT DETECTOR BASE' MODEL DB -11 OR MODEL DB -3 WITH DB-ADPT OPTIONAL REMOTE ALARM INDICATOR MODELS RLI-1/RLI-2 DETECTOR BASE FOR USE WITH FP -II SMOKE DETECTOR AND FPT-11 HEAT DETECTOR HFP-11 /HFPT-11 DETECTOR WIRING CEILING TILE CEILING STROBE TYPICAL DEVICE LAYOUT BOX SUPPORT BRIDGE 4S DEEP BOX W/ 4S EXTENSION WIRE DESIGNATIONS NS-24MCC-FW HORN/STROBE RSS-24MCCR-FW Copyright 2002 by Guardian Security Systems, Inc. All Rights Reserved 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 (/) Z rn W w U) W Lu IREV. BY: 1 V) mm 0 V) 0 DESCRIPTION SUBNA ITTEO FOR APPROVALI 1 I 4 W O. Z 0 V) W r DATE , CD CD s\ c N s <a«< N UW 0 CC (i)o Noy o a m IO) < W 17_ F - o03 w aNrg . () _ 2 z� OF - z 4 ° w U cc C� SCALE: AS NOTED IL DRAWN BY: D. SAGRELIUS DESIGNED BY: D. SAGRELIUS DATE: 11/01/0 6 BACKROUND PLAN PROVIDED BY: EHS ELECTRIC JOB NUMBER: 541 1 j SHEET FA -01» M:\iirawings\Krq Cour* Water J strict -i25\FAJ7wg5\FA-02 dwq, II/ 27/ 2006 2:03:0I PM, f?MG FR 655 INC. STORAGE__ A-20 165 SF SERVER / PLOTTER AREA A-08 101 SF GEN. MANAGER A-07 156 SF WK STATION A-06 98 SF ADMIN. SEC. A-05 134 SF ESD RE UNISEX-ADA-SHW r S1-6 B-21 S1- ICTRICAL ==, C-13 23 SF 9SF 0_ I ACP D DW JAN. S,S' 15 t f S2\4 \15c s2= MAIL AREA A-21 ENTRY 'A' e 225 SF HALL A-22 15cd- -- S1 Ocd 1--8 61 SF cd CPC LU 0 H/TWIINI (A-3) \ 99 F 2 PANTRY C-08 L"OITRY'B' c-1 81 3-2 61 STOR. B-17 50 SF D o 13 SF D S 0 DS FSD FS D -- STORAGE C-05 14 SF STORAGE S,S' o TO=_=-R IN ELCTRI ROOM `\ FSD p HALL A-09 WORK AREA A-13 110 SF FIRE VAULT A-17 94 SF REF -- OFFICE SUPPLIES A-12 71 SF INSPECTOR A-11 72 SF 30cd S1-10 INSPECTOR A-10 73 SF S2-2 MEETING ROOM (A-3) C-04 931 SF HALL A-14 PAYROLL A-04 122 SF 30cd S1-11 S 15cd S1-13 CONTRACTOR/ MAP RM A-15 149 SF FN S FSD 30cd S3-8 WK STATION A-03 107 SF RECEPTION A-02 85 SF TI 15cd S1-12 LOBBY A-01 181 SF FSD FACPC LEC. CLST B-22 28 SF FIRE VAULT B-13 94 SF / COATS B-23 9 SF "_ 30cd S3-4 CONF./ADJOURNMENT 3-08 322 SF _ 4 1 CONTRACTOR/ MAP RM B-05 130 SF S 15cd S3-6 MAIN LOBBY C-01 256 SF H. A 4 MF SCALE — 1 /4" = 1' NORTH LOBBY 3-01 135 SF RECEPTION 1. B-02 66 SF 14, fr HALL 8-15 132 SF 15cd S3-2 MAII../WORK RM B-12 158SF GENERAL MGR. B-16 150 SF 15cd S3-3 HA B-1 16' 0 SF 1 IF WORKFILES n-04 280 SFS 95cd S3-5 WORKSTATION 3-03 151 SF WORK STATION 3-14 77 SF OFFICE MGR. B-11 150 SF SERVER/AUDITOR ASSIST. OFFICE MGR. B-06 120 SF Copyright 2002 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 TEL. (206) 622-6545 U) 0 W w C/) w J W REV. BY: mm 0 0 DESCRIPTION SUBMITTED FOR APPROVAL -I I 4 lY W 1 VI z 0 V) > hi DATE CD ON 9 <aaaa (co N �U Lc°w Er" rfiro d vi r fA 0 CO ° II 0 03J z Q o �3 Q erg 2(Ci 94t clinx o° 111 U 0 U.SCALE: AS NOTED 0. DRAWN BY: D. SAGRELIUS DESIGNED BY: D. SAGRELIUS DATE: 11/01/0 6 BACKROUND PLAN PROVIDED BY: EHS ELECTRIC •OB NUMBER: 54 1 1 SHEET FA -02