HomeMy WebLinkAboutPP - 18125 ANDOVER PARK WEST - SEGALE BUILDING 761 - PERMITS AND PLANS18125 ANDOVER PARK WEST ASSOCIATED PERMITS 13-F-171 09-F-113 SITE LOCATION Site Address: Tenant Name: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** AID J w 2013 TU I IRE King Co. Assessor's Tax No.: 35Z 34(4 91'n lv 6-fC Q,6' inclL�i ' W Suite Number: Floor: tebte.10( r76 pe. Pc-apex-AlesL L C A,O %)( M(r luKw► �. City State Zip Property Owner's Name: Mailing Address: New Tenant? ❑ - Yes -No tdA ql3f- CONTACT PERSON -if there are questions about the submittal. Name: MOCK I\ACT. t1C.11'1 Day Telephone: 219( 12( Company Name: ViAGATM CS1 t A -5:1\1L Mailing Address: 2-030 f -1f(` fk. Seckik e_ WA $134 E-mail Address: filt ,i i4aGin��tOG4kg5bnaY,frn • GOAN City Fax Number: 1'ht 3214r Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Rap le e O 0 lfA-e ce Ara ' th ttj +thns p li er w rkL AC -5 f c.c(;0 PERMIT APPLICATION NOTES Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Mos( Mc:Om:I v; Plan Permit App.doc Day Telephone: Date: / - /6' 2a3 2i%•3zr-3 8 5/14/10 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Type of Inspectio : Address:,w l Suite #: LS �of�V ��/ Contact Perso Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: / Fire Alarm: Hood & Duct: r Pre -Fire: Permits: Occupancy Type: --rov, . - ,-:= . _ _ - - ._ . rMs\ 5p4 I+ to 06 a (___ A Ay-_ 0/d 5ys4 5/ -ores Atri t --:-?J Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:�� Date: 7 /y' fit/ Hlrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECO Retain a copy with per - it FAL m I3Fi2/ PERMIT NUMBERS CITY OF TUKWILA FIREDEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 5e5c, /.< 74 J Type of Inspection: Address: /pa r ,-e- LitJ . Suite #: Contact Person: ,(/i i kk /2.6.'0-‘501--, Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: CQi 1A Vero -4-r Covvcc/fij •c 1 2-O•0) h.,+ Permits: 1:tiv5 ll IP ',titter f�wd) k L I4 r Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: / I Date: S -5 -(Lf Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: tit Lk 12015, �►, Address: '2,o'30 A-770,4 Ud / 5. City: 5-cciAi1,c Company Name: ("aft- ,4 l y v k% State: Zip Q/>7 /31 Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 CONFIDENTIAL A FIRE ALARM SYSTEMS BATTERY CALCULATION CHART B C D E F Form: 1/22/01 G WAS H I N G T O N A L A I? DEVICE/ MODULE MODEL NUMBER QUANTITY OF DEVICE/ MODULE STANDBY CURRENT (AMPS) TOTAL STANDBY CURRENT (CxD) ALARM CURRENT (AMPS) TOTAL ALARM CURRENT (CxF) AES-Segale 761 CONTROL PANEL AND MODULES 0 0 AES Radio transmitter 7788F 1 0.15 0.15 1.2 1.2 AES Intellitap 7794 1 0.06 0.06 0.1 0.1 0 0 Battery 12 VOLTS SLA1075 1 0 0 0 0 0 0 0 0 0 0 0 0 Sum Column For Standby Load (Amps) Multiply By Required Standby Time (24 or 60 Hours) Total Standby AH 0.210 24 5.040 (G) Sum Column For Alarm Load (Amps) Multiply By Required Alarm Time (5 min = .083) Total Alarm AH 1.300 0.083 0.108 TOTAL TOTAL REQUIRED SAFETY TOTAL TOTAL STANDBY ALARM AH AH (G+H) FACTOR SYSTEM SYSTEM AH (G) (H) (Multiply) AMPERE- AMPERE - HOURS HOURS REQUIRED PROVIDED 5.040 0.1079 5.148 1 1.3 6.692 7.5AH • twice Fire & Security SimplexGrinnell SCOPE DATE: Tues July 22 2009 To : Tukwila Fire Dept. Fire Prevention 444 Andover Park East Tukwila, WA 98188 206 575 4404. TFD Fax 206 575 4439 SimplexGrinnell LP 9520 10th Ave South Suite 100 Seattle, WA 98108 Voice: 206-291-1400 Fax: 206-291-1500 www. simplexgrinneli com Regarding : Continental Mills 18125 And West . Main Floor Computer Room. Applying for FA Permit. Scope of work : Add and or tie in spare relay from existing halon releasing system such that when first halon action starts, relay will shut off new air cooler system. John Solbakken. SimplexGrinnell. Ph 206 291 1424. Cell 206 391 8024 FAX 206 291 1500/ We are pleased t sprinkler sy We mit our qu work outlined • • ve included: Design and installa Required permit We have not include 1. Painting, an or pr • tation of AMOUNT ($0,000) to complete the automatic fire elow. n in accordance w • PA d/or plan chec s for this installa on. ration to paint, system compon nts. PAID JUL 24 2009 Tukwila Fire 2. Electric ring, labo and materials, of devices. 3. Cent1 station monito ' ng and/or fire alarm annunciation. 4. Washington State Sa s Tax Concealment, furri and/or soffitting of piping. Firestopping and/ r firesafeing of penetrations. ualifications/Clari r cations 1. This quotati'n is based upon work being perf ed during normorking hours and days. Thank you for e opportunity to submit this roposal. This quotatio is valid for a period of thirty (30) days, a ` -r which it will be subject to our review. The priceoted is subject to a mutually acceptable bcontract. If you have . questions, or require further clarification, please do not hesitate tq�contact me. Sincer y, SI PLEXGRI ►' ' ELL Name Sales Representative Accepted By: Tit Date: • IWO I Fire & /s!mp!exGr!naell Security 9520 10th Avenue S., Suite 100 • Seattle, Washington 98108 Phone: (206) 291-1400 • Fax (206) 291-1500 [S7JECT: m i -tire Afi( _ DATE: BY: 7.--1,7-004 $ct.g PAGE: 1 I olvy\A a a 4 4 • • a a a 4 • 4 4 a a 4 a • 4 a • a 4 a E E O a 4 a 4 r f3®Simplex UL, CSFM Listed; MEA (NYC) Acceptance* System Accessories Fire Alarm Control Relays, Track Mount and Encapsulated; Model 4098-9843 and 2088 Series I UL listed under Standard 864 as Control Unit Accessory (UOXX) Track mount package availability: • Single relay module or four relay module, with or without cover, with SPDT or DPDT contacts • LED indicates relay module status • Cover provide status LED viewing ports • Multiple coil voltage inputs, diode polarized for DC • Modules are track mounted with snap -apart feature design allowing the four relay module to be separated Single encapsulated SPDT relay package with color coded 18 AWG wire leads, available in two versions: • 2088-9021 (PAM -1) Provides diode polarized multiple input voltage ability and LED indication • 4098-9843 (PAM -SD) Provides a diode polarized 24 VDC coil with in/out wiring Descri tion These multi-purpose control relays offer SPDT or DPDT, 10 A (or 7 A) contacts in a variety of mechanical packages. Models are available for coil operation by one of four input voltages allowing a single relay to be energized from a voltage source of 18-35 VDC or VAC, 120 VAC, or 230 VAC (not available with 4098-9843). Voltage selection is made by wiring to the appropriate input terminals or wire leads. Each relay model (except model 4098-9843) contains a red LED which indicates that the relay is energized. Mounting options are varied for application flexibility. Track mounted relays may be "snapped apart" from a standard four -module assembly and used independently if desired. S ecifications Track Mount Relays, see page 2 for dimensions Coll Vottage 18-35 VACNDC, 120, or 230 VAC Coil Current SPDT models = 18 mA DPDT models = 40 mA Terminal Blocks Up to 1 4 AWG (2.08 mm2 ) 10 A@ 120 VAC Contact Ratings N.O. rated 1/6 HP, N.C. rated 118 HP 7A @ 28 VDC and @ 230 VAC Temperature Ratings UL Listed Range 32° F to 120° F (0° C to 49° C) Operating Range -58° F to 185° F (-50° C to 85° C) Humidity 85% RH Non -condensing c'!IMILVM 000600 606600@ 000000 000000 =1° i 4r,,maw 0000 • • 600(5 *°, 1° pigt Mme] M® 0000 0009 • , m• matiammwessffsamsmaimemmumum 2088-9020, MR204/C, Four DPDT Relay Package with Enclosure (shown with cover removed) Encapsulated Relay Package (typical of 2088-9021, PAM -1 and 4098-9843, PAM -SD) Specifications Continued Encapsulated Relays, see page 2 for dimensions Connections 118 AWG (0.82 mm2) color -coded wire leads Relay 2088-9021 Contact Ratings 10 A @ 120 VAC, resistive Coil Voltage Ratings Current 18-35 VACNDC, 120, or 240 VAC 15 mA @ 24 VACNDC, & @ 120 or 230 VAC Relay 4098-9843 Coil Ratings 18-32 VDC input, polarized, 15 mA @ 24 VDC Contact Ratings Temperature Ratings UL Listed Range Operating Range Humidity 7 A at 0.35 p.f @ 28 VDC & 120 VAC 250 NA@5VDC 32° F to 120° F (0° C to 49° C) -58° F to 185° F (-50° C to 85° C) 85% RH Non -condensing • product listings are by AIr Products & Controls Inc. (mow. ap-c.com) per model numbers shown on page 2. These products are also available through Space Age Electronics Inc. (wwx.lsae.com) with an SSU- prefix. S2088-0010-8 3/2008" Relay Selection Chart Module Positions Reference Number Air Products Modal Relay Type Packaging Dimensions 2088-9007 MR -101/T SPDT Track mount, without cover 3-1/4" H x 2-1/8" W x 1-1/2" D 2088-9009 MR -201/T DPDT V (83 mm x 54 mm x 38 mm) On 2088-9008 MR -101/C SPDT 5-1/8" H x 3-1/8" W x 2-1/2' D 2088-9010 MR -201/C DPDT Track mount with cover (131 mm x 79 mm x 64 mm) 2088-9017 MR -104/T SPDT 3-1/4" H x 8-1/2" W x 1-1/2" D Four 2088-9019 MR -204/T DPDT Track mount, without cover (83 mm x 216 mm x 38 mm) 2088-9018 MR -104/C SPDT 5-1/8" H x 9-1/2" W x 2-1/2" D 2088-9020 MR -204/C DPDT Track mount with cover (131 mm x 241 mm x 64 mm) 2088-9021 PAM -1 Encapsulated, multi -voltage coil, color coded 18 AWG (0.82 mm2) wire leads, with coil status LED 1-1/2" H x1" W x 7/8' D (38 mm x 25.4 mm x 22 mm) NA SPDT 4098-9843 PAM Encapsulated, 24 VDC coil, color coded 18 AWG 1-1/2" H x 1-3/16" W x 13/16" D -SD (0.82 mm2) wire leads (no LED) (38 mm x 30 mm x 21 mm) Track Mount Rela Wirinc Reference Coil voltage (note polarity for DC) SPDT contacts rated 10 A @ 120 VAC, resistive (18-35) VDC (18-35) VAC 120 VAC 230 VAC (-) (+) AC AC N V ■ V V Terminal strip connections SPDT models DPDT contacts rated ,10 A © 120 VAC, resistive NC C NO NC C NO Relay energized LED - Coil voltage (note polarity for DC) ®®®® ® 0 18/24 115 230 (18-35) VDC (18-35) VAC 120 VAC 230 VAC I (-) (+) AC AC N V ■ V V Terminal strip connections DPDT models Tyco, Simplex, and the Simplex logo are trademarks of 7)rco International Services AG or Its affiliates in the US. and/or other countries. Include any other peninent trademark informa#on here i. e.: NFPA 72 and National Fire Alarm Code are registered trademarks of the Notional Fire Protection Association (NFPA). �3eSimplex Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA 52088-0010-8 3/2006 www.tycosafetyproducts usa-wm,cora 1,2006 Tyco Safety Products Wesnninster. All rights reserved All spec,catloru and otter information shown were current as ofdocument revision date and are subject to change without notice. ACC PTSD 'T Without Comments ❑ As Red ❑ Per T1 c At~acned Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for co"formance with current City standards. Acceorcrc:•' i:y subject to errors and omissions which do noc authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this da .o will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 7/ 2 (1/ 0 v: / '1 ( tuiwitA FIRE DEPARtastilat Please call: 575.4407, and give this job and exact address for shut. Town or restoration aoorovel NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Ttnspector prior to cofnmencemer►t of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and cerrnination of the testing. FILE See detail at right for zones & EOL resistors S1075 12V 7.5Ah Battery SCOPE OF WORK: Replace existing dialer central station transmitter with AES radio. Existing zones will report via the radio. Washington Alarm Inc will continue to provide maintenance, annual inspections and central station monitoring. Pke, Riser Diagram for Segale 761 TO WASHINGTON MANY QMTWI. STATION Zone 1: Zone 3: Zone 5: Zone Sprinkler Water Smoke Dets & Trouble on Local Local Panel Flow -Throughout Manual pulls Fire panel Tamper 2nd flr b opb opb o4b op Zone 2: Zone 4: Zone 6: Zone 8: Smoke Dets & Halon System for Hold Up Button Supervisory- 2 Manual pulls 1st flr computer rm. (Non Fire Zone) Duct smoke dets. 120 VAC (DEDICATED CKT.) 120 VAC (DEDICATED OCT.) To A Zones. See diagram at left. FIRE ALARM CONTROL PANEL �. 0%14,4- s1.441,e kJ' ate``,4C ,, . s. 6•��w ►lt►jI( c,Igvi Locol FACP monitor existing initiating devices and suppression PAID JU/1��1013 TUKFIRE \ilk WASHINGTONALARM SEGALE PROPERTIES -,BUILDING 761 AES RADIO TRANSMITTER 18125 ANDOVER PARK W. TUKWILA, WASHINGTON 98188 WASHINGTON ALARM INC. 2030 Airport Way South Seattle, WA. 98134 Job # 9608 Drawn by Mark Mcllwain Ph: 206-328-3288 Fax 206-322-7214 RENS/ONS DATE DESCRIPTION 7/10/2013 PERMIT SET FIRE ALARM FA -1 ACCEPTED ❑ a"ni..t Comments As •jin ''pled ❑ Per The Attached Letter i,:ce plans have E c : re' ie ;s i hy The Tukwila Fire wo current City '.'dards. ATors and wh!c; ? "d . ;';`a. ons of adopted ,-lards -3S,_•.:-canis ty for the ,uacy o;. cJ _ S,:; -e r ::: ::: :,e ;resigner. -''.+ions, f:@WrE .:4' i �:��,ur .:, to i_hese; drawings after •jate: „-;s �c'it� %°� w a..°� �i-d wlii require ' submitta: of for su quen pp val. °Enal acceptance is subject to field to ion by The Tukwila Fire Prevention Bureau.Alie‘n Uate: .."7/;-)—P By: �l 'TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. and exact oreeac t(ad yrs for shut- downre ,:c. ,at:111 G'ppB oval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to ,:commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and 1-,rrnination of the testing 18125 ANDOVER PARK WEST ASSOCIATED PERMITS 13-F-171 09-F-113 SITE LOCATION Site Address: Tenant Name: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** AID J w 2013 TU I IRE King Co. Assessor's Tax No.: 35Z 34(4 91'n lv 6-fC Q,6' inclL�i ' W Suite Number: Floor: tebte.10( r76 pe. Pc-apex-AlesL L C A,O %)( M(r luKw► �. City State Zip Property Owner's Name: Mailing Address: New Tenant? ❑ - Yes -No tdA ql3f- CONTACT PERSON -if there are questions about the submittal. Name: MOCK I\ACT. t1C.11'1 Day Telephone: 219( 12( Company Name: ViAGATM CS1 t A -5:1\1L Mailing Address: 2-030 f -1f(` fk. Seckik e_ WA $134 E-mail Address: filt ,i i4aGin��tOG4kg5bnaY,frn • GOAN City Fax Number: 1'ht 3214r Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Rap le e O 0 lfA-e ce Ara ' th ttj +thns p li er w rkL AC -5 f c.c(;0 PERMIT APPLICATION NOTES Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Mos( Mc:Om:I v; Plan Permit App.doc Day Telephone: Date: / - /6' 2a3 2i%•3zr-3 8 5/14/10 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Type of Inspectio : Address:,w l Suite #: LS �of�V ��/ Contact Perso Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: / Fire Alarm: Hood & Duct: r Pre -Fire: Permits: Occupancy Type: --rov, . - ,-:= . _ _ - - ._ . rMs\ 5p4 I+ to 06 a (___ A Ay-_ 0/d 5ys4 5/ -ores Atri t --:-?J Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:�� Date: 7 /y' fit/ Hlrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECO Retain a copy with per - it FAL m I3Fi2/ PERMIT NUMBERS CITY OF TUKWILA FIREDEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 5e5c, /.< 74 J Type of Inspection: Address: /pa r ,-e- LitJ . Suite #: Contact Person: ,(/i i kk /2.6.'0-‘501--, Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: CQi 1A Vero -4-r Covvcc/fij •c 1 2-O•0) h.,+ Permits: 1:tiv5 ll IP ',titter f�wd) k L I4 r Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: / I Date: S -5 -(Lf Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: tit Lk 12015, �►, Address: '2,o'30 A-770,4 Ud / 5. City: 5-cciAi1,c Company Name: ("aft- ,4 l y v k% State: Zip Q/>7 /31 Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 CONFIDENTIAL A FIRE ALARM SYSTEMS BATTERY CALCULATION CHART B C D E F Form: 1/22/01 G WAS H I N G T O N A L A I? DEVICE/ MODULE MODEL NUMBER QUANTITY OF DEVICE/ MODULE STANDBY CURRENT (AMPS) TOTAL STANDBY CURRENT (CxD) ALARM CURRENT (AMPS) TOTAL ALARM CURRENT (CxF) AES-Segale 761 CONTROL PANEL AND MODULES 0 0 AES Radio transmitter 7788F 1 0.15 0.15 1.2 1.2 AES Intellitap 7794 1 0.06 0.06 0.1 0.1 0 0 Battery 12 VOLTS SLA1075 1 0 0 0 0 0 0 0 0 0 0 0 0 Sum Column For Standby Load (Amps) Multiply By Required Standby Time (24 or 60 Hours) Total Standby AH 0.210 24 5.040 (G) Sum Column For Alarm Load (Amps) Multiply By Required Alarm Time (5 min = .083) Total Alarm AH 1.300 0.083 0.108 TOTAL TOTAL REQUIRED SAFETY TOTAL TOTAL STANDBY ALARM AH AH (G+H) FACTOR SYSTEM SYSTEM AH (G) (H) (Multiply) AMPERE- AMPERE - HOURS HOURS REQUIRED PROVIDED 5.040 0.1079 5.148 1 1.3 6.692 7.5AH • twice Fire & Security SimplexGrinnell SCOPE DATE: Tues July 22 2009 To : Tukwila Fire Dept. Fire Prevention 444 Andover Park East Tukwila, WA 98188 206 575 4404. TFD Fax 206 575 4439 SimplexGrinnell LP 9520 10th Ave South Suite 100 Seattle, WA 98108 Voice: 206-291-1400 Fax: 206-291-1500 www. simplexgrinneli com Regarding : Continental Mills 18125 And West . Main Floor Computer Room. Applying for FA Permit. Scope of work : Add and or tie in spare relay from existing halon releasing system such that when first halon action starts, relay will shut off new air cooler system. John Solbakken. SimplexGrinnell. Ph 206 291 1424. Cell 206 391 8024 FAX 206 291 1500/ We are pleased t sprinkler sy We mit our qu work outlined • • ve included: Design and installa Required permit We have not include 1. Painting, an or pr • tation of AMOUNT ($0,000) to complete the automatic fire elow. n in accordance w • PA d/or plan chec s for this installa on. ration to paint, system compon nts. PAID JUL 24 2009 Tukwila Fire 2. Electric ring, labo and materials, of devices. 3. Cent1 station monito ' ng and/or fire alarm annunciation. 4. Washington State Sa s Tax Concealment, furri and/or soffitting of piping. Firestopping and/ r firesafeing of penetrations. ualifications/Clari r cations 1. This quotati'n is based upon work being perf ed during normorking hours and days. Thank you for e opportunity to submit this roposal. This quotatio is valid for a period of thirty (30) days, a ` -r which it will be subject to our review. The priceoted is subject to a mutually acceptable bcontract. If you have . questions, or require further clarification, please do not hesitate tq�contact me. Sincer y, SI PLEXGRI ►' ' ELL Name Sales Representative Accepted By: Tit Date: • IWO I Fire & /s!mp!exGr!naell Security 9520 10th Avenue S., Suite 100 • Seattle, Washington 98108 Phone: (206) 291-1400 • Fax (206) 291-1500 [S7JECT: m i -tire Afi( _ DATE: BY: 7.--1,7-004 $ct.g PAGE: 1 I olvy\A a a 4 4 • • a a a 4 • 4 4 a a 4 a • 4 a • a 4 a E E O a 4 a 4 r f3®Simplex UL, CSFM Listed; MEA (NYC) Acceptance* System Accessories Fire Alarm Control Relays, Track Mount and Encapsulated; Model 4098-9843 and 2088 Series I UL listed under Standard 864 as Control Unit Accessory (UOXX) Track mount package availability: • Single relay module or four relay module, with or without cover, with SPDT or DPDT contacts • LED indicates relay module status • Cover provide status LED viewing ports • Multiple coil voltage inputs, diode polarized for DC • Modules are track mounted with snap -apart feature design allowing the four relay module to be separated Single encapsulated SPDT relay package with color coded 18 AWG wire leads, available in two versions: • 2088-9021 (PAM -1) Provides diode polarized multiple input voltage ability and LED indication • 4098-9843 (PAM -SD) Provides a diode polarized 24 VDC coil with in/out wiring Descri tion These multi-purpose control relays offer SPDT or DPDT, 10 A (or 7 A) contacts in a variety of mechanical packages. Models are available for coil operation by one of four input voltages allowing a single relay to be energized from a voltage source of 18-35 VDC or VAC, 120 VAC, or 230 VAC (not available with 4098-9843). Voltage selection is made by wiring to the appropriate input terminals or wire leads. Each relay model (except model 4098-9843) contains a red LED which indicates that the relay is energized. Mounting options are varied for application flexibility. Track mounted relays may be "snapped apart" from a standard four -module assembly and used independently if desired. S ecifications Track Mount Relays, see page 2 for dimensions Coll Vottage 18-35 VACNDC, 120, or 230 VAC Coil Current SPDT models = 18 mA DPDT models = 40 mA Terminal Blocks Up to 1 4 AWG (2.08 mm2 ) 10 A@ 120 VAC Contact Ratings N.O. rated 1/6 HP, N.C. rated 118 HP 7A @ 28 VDC and @ 230 VAC Temperature Ratings UL Listed Range 32° F to 120° F (0° C to 49° C) Operating Range -58° F to 185° F (-50° C to 85° C) Humidity 85% RH Non -condensing c'!IMILVM 000600 606600@ 000000 000000 =1° i 4r,,maw 0000 • • 600(5 *°, 1° pigt Mme] M® 0000 0009 • , m• matiammwessffsamsmaimemmumum 2088-9020, MR204/C, Four DPDT Relay Package with Enclosure (shown with cover removed) Encapsulated Relay Package (typical of 2088-9021, PAM -1 and 4098-9843, PAM -SD) Specifications Continued Encapsulated Relays, see page 2 for dimensions Connections 118 AWG (0.82 mm2) color -coded wire leads Relay 2088-9021 Contact Ratings 10 A @ 120 VAC, resistive Coil Voltage Ratings Current 18-35 VACNDC, 120, or 240 VAC 15 mA @ 24 VACNDC, & @ 120 or 230 VAC Relay 4098-9843 Coil Ratings 18-32 VDC input, polarized, 15 mA @ 24 VDC Contact Ratings Temperature Ratings UL Listed Range Operating Range Humidity 7 A at 0.35 p.f @ 28 VDC & 120 VAC 250 NA@5VDC 32° F to 120° F (0° C to 49° C) -58° F to 185° F (-50° C to 85° C) 85% RH Non -condensing • product listings are by AIr Products & Controls Inc. (mow. ap-c.com) per model numbers shown on page 2. These products are also available through Space Age Electronics Inc. (wwx.lsae.com) with an SSU- prefix. S2088-0010-8 3/2008" Relay Selection Chart Module Positions Reference Number Air Products Modal Relay Type Packaging Dimensions 2088-9007 MR -101/T SPDT Track mount, without cover 3-1/4" H x 2-1/8" W x 1-1/2" D 2088-9009 MR -201/T DPDT V (83 mm x 54 mm x 38 mm) On 2088-9008 MR -101/C SPDT 5-1/8" H x 3-1/8" W x 2-1/2' D 2088-9010 MR -201/C DPDT Track mount with cover (131 mm x 79 mm x 64 mm) 2088-9017 MR -104/T SPDT 3-1/4" H x 8-1/2" W x 1-1/2" D Four 2088-9019 MR -204/T DPDT Track mount, without cover (83 mm x 216 mm x 38 mm) 2088-9018 MR -104/C SPDT 5-1/8" H x 9-1/2" W x 2-1/2" D 2088-9020 MR -204/C DPDT Track mount with cover (131 mm x 241 mm x 64 mm) 2088-9021 PAM -1 Encapsulated, multi -voltage coil, color coded 18 AWG (0.82 mm2) wire leads, with coil status LED 1-1/2" H x1" W x 7/8' D (38 mm x 25.4 mm x 22 mm) NA SPDT 4098-9843 PAM Encapsulated, 24 VDC coil, color coded 18 AWG 1-1/2" H x 1-3/16" W x 13/16" D -SD (0.82 mm2) wire leads (no LED) (38 mm x 30 mm x 21 mm) Track Mount Rela Wirinc Reference Coil voltage (note polarity for DC) SPDT contacts rated 10 A @ 120 VAC, resistive (18-35) VDC (18-35) VAC 120 VAC 230 VAC (-) (+) AC AC N V ■ V V Terminal strip connections SPDT models DPDT contacts rated ,10 A © 120 VAC, resistive NC C NO NC C NO Relay energized LED - Coil voltage (note polarity for DC) ®®®® ® 0 18/24 115 230 (18-35) VDC (18-35) VAC 120 VAC 230 VAC I (-) (+) AC AC N V ■ V V Terminal strip connections DPDT models Tyco, Simplex, and the Simplex logo are trademarks of 7)rco International Services AG or Its affiliates in the US. and/or other countries. Include any other peninent trademark informa#on here i. e.: NFPA 72 and National Fire Alarm Code are registered trademarks of the Notional Fire Protection Association (NFPA). �3eSimplex Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA 52088-0010-8 3/2006 www.tycosafetyproducts usa-wm,cora 1,2006 Tyco Safety Products Wesnninster. All rights reserved All spec,catloru and otter information shown were current as ofdocument revision date and are subject to change without notice. ACC PTSD 'T Without Comments ❑ As Red ❑ Per T1 c At~acned Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for co"formance with current City standards. Acceorcrc:•' i:y subject to errors and omissions which do noc authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this da .o will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 7/ 2 (1/ 0 v: / '1 ( tuiwitA FIRE DEPARtastilat Please call: 575.4407, and give this job and exact address for shut. Town or restoration aoorovel NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Ttnspector prior to cofnmencemer►t of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and cerrnination of the testing. FILE See detail at right for zones & EOL resistors S1075 12V 7.5Ah Battery SCOPE OF WORK: Replace existing dialer central station transmitter with AES radio. Existing zones will report via the radio. Washington Alarm Inc will continue to provide maintenance, annual inspections and central station monitoring. Pke, Riser Diagram for Segale 761 TO WASHINGTON MANY QMTWI. STATION Zone 1: Zone 3: Zone 5: Zone Sprinkler Water Smoke Dets & Trouble on Local Local Panel Flow -Throughout Manual pulls Fire panel Tamper 2nd flr b opb opb o4b op Zone 2: Zone 4: Zone 6: Zone 8: Smoke Dets & Halon System for Hold Up Button Supervisory- 2 Manual pulls 1st flr computer rm. (Non Fire Zone) Duct smoke dets. 120 VAC (DEDICATED CKT.) 120 VAC (DEDICATED OCT.) To A Zones. See diagram at left. FIRE ALARM CONTROL PANEL �. 0%14,4- s1.441,e kJ' ate``,4C ,, . s. 6•��w ►lt►jI( c,Igvi Locol FACP monitor existing initiating devices and suppression PAID JU/1��1013 TUKFIRE \ilk WASHINGTONALARM SEGALE PROPERTIES -,BUILDING 761 AES RADIO TRANSMITTER 18125 ANDOVER PARK W. TUKWILA, WASHINGTON 98188 WASHINGTON ALARM INC. 2030 Airport Way South Seattle, WA. 98134 Job # 9608 Drawn by Mark Mcllwain Ph: 206-328-3288 Fax 206-322-7214 RENS/ONS DATE DESCRIPTION 7/10/2013 PERMIT SET FIRE ALARM FA -1 ACCEPTED ❑ a"ni..t Comments As •jin ''pled ❑ Per The Attached Letter i,:ce plans have E c : re' ie ;s i hy The Tukwila Fire wo current City '.'dards. ATors and wh!c; ? "d . ;';`a. ons of adopted ,-lards -3S,_•.:-canis ty for the ,uacy o;. cJ _ S,:; -e r ::: ::: :,e ;resigner. -''.+ions, f:@WrE .:4' i �:��,ur .:, to i_hese; drawings after •jate: „-;s �c'it� %°� w a..°� �i-d wlii require ' submitta: of for su quen pp val. °Enal acceptance is subject to field to ion by The Tukwila Fire Prevention Bureau.Alie‘n Uate: .."7/;-)—P By: �l 'TUKWILA FIRE DEPARTMENT Please call 206-5754407 and give this Fire Permit No. and exact oreeac t(ad yrs for shut- downre ,:c. ,at:111 G'ppB oval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to ,:commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and 1-,rrnination of the testing