HomeMy WebLinkAboutPP - 4439 S 134TH PL BLDG #E - FOSTORIA PARK BUILDING #E - PERMITS AND PLANS4439 S 134TH PL BLDG #E
ASSOCIATED PERMITS
18-F-024
14-F-160
08-F-119
14-S-013
08-S-041
SITE LOCATION
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.: 2613200084
Site Address: 4439 SOUTH 134TH PL Tukwila , Wa Suite Number: A, Floor:
Tenant Name: S EATAC LIGHTING New Tenant? ❑ - Yes ® - No
Property Owner's Name: FO5TOR69 "kflc 11.5 t% C . L. G
Mailing Address:
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: Martin Traicoff
Company Name: Cosco Fire Protection
Day Telephone: 206-438-3376
Mailing Address: 4308 S 131ST PL TUKW I LA , WA 98168
City State Zip
E-mail Address: MTRAICOFF@COSCOFIRE . COM Fax Number:
Valuation of Project (contractor's bid price): $ 3,500
Scope of Work (please provide detailed information): Add 12 Pendent heads in office extension
in to existing warehouse space.
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER
0 • AU - 1 RIZED
Signature: i%/ Date: 147/9
Print Name: Ma Traicoff Day Telephone: 206-438-3376
Plan Permit App.doc
5/14/10 TFD FP Form 8
41310,44
SITE LOCATION
CITY OF TUKWILA
FIRE MARSHAL'S OFFICE
206-575-4407
F tit
FIRE PROTECTION SYSTEMS PERMIT APPLICATI
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
Eft
/39/4.- King Co. Assessor's Tax No.:
Site Address: 1'/ 31 S. p1- Suite Number: * Floor:
Tenant Name: Sew To.e . L 104 i Y1C1 T. 1 New Tenant? ❑ - Yes ig - No
Property Owner's Name: FS J'\ ?COQC.C'(�N e -S
Mailing Address: 161)0 S Z(t?i''- SI— SO ` \" 1' I /it 1/0/UC, w qgoo‘
City
CONTACT PERSON -if there are questions about the submittal.
Name: 3i.4(\ 61 i ZIY�_yc i•
Company Name: Fri' kZVI_ 0. - �Cz c4jk
State Zip
Day Telephone:p.s3- 566 3
Mailing Address:
E-mail Address: �CIS4-i
Zrt, klo<1-Se th/G. Lo yvl
City Stat, e� Zip
Fax Number li 6_ 163 — 7 •,G6\
Total number of new/relocated devices or sprinkler heads:
Valuation of Project (contractor's bid price): $ ysd
Scope of Work (please provide detailed information): A� � h Zun� L�f C
X
1/bral (6,12k, pLe..
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWL ER I ' -- • RIZED AGENT:
Sign..•
Plan Permit App.doc
6/4/14
Date: 7M/�.y
Day Telephone: 3- 3 S - Sc>
TFD FP Form 8
44
IMRE
SITE LOCATION
CITY OF TUKWILA
FIRE MARSHAL'S OFFICE
206-575-4407
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.: R7Rff17flflfll O
Site Address: 4439 SOUTH 134TH PL. (BLDG. E), TUKWILA, WA 98168 Suite Number: Floor:
Tenant Name: FOSTORIA INVESTMENT PROPERTY LLC
Property Owner's Name:FOSTORIA INVESTMENT PROPERTY
New Tenant? ❑ - Yes ® - No
Mailing Address: 15100 SE 38TH STREET #792 BELLEVUE WA 98006
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: JUSTIN FIESS Day Telephone:(360) 491-6320/
(360) 481-4969
CompanyName:ALARM CENTER, INC.
Mailing Address:PO BOX 3407 LACEY WA 98509
City State Zip
E-mail Address: justin@alarmcenterinc.com Fax Number:(360) 438-4244
Contractor's City of Tukwila Business License number: BUS -0992830
Total number of new/relocated devices or sprinkler heads: 1
Valuation of Project (contractor's bid price): $ 1,495.00
Scope of Work (please provide detailed information): INSTALL NEW A.E.S. FIRE ALARM COMMUNICATOR AND
CONNECT TO EXISTING FACP.
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name: JUSTIN FIESS
Plan Permit App.doc
Date: 01/12/2018
Day Telephone: (360) 481-4969
8/22/14 TFD FP Foim 8
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Seatac Lighting
4439 S 134th PI
Permit No.: 14-S-013
Date: January 28, 2014
Reviewer: Al Metzler
Fire Protection Project Coordinator
(206) 575-4407 option # 2 (Inspection Requests)
(206) 971-8718 (Plan Review Questions)
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the last length of
pipe but within 6' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40 ' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2 for pipe size 2 1/2 inches and larger.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-02, section 9.6.2.6.2 (e).
• Ceilings used for flex drop attachments shall comply with ASTM C 635 and
ASTM C 636 per section 9.2.1.3.3.2.
• Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a
suspended ceiling, a hanger(s) attached to the structure shall be required to
ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3).
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
• Comply with obstructed/non-obstructed construction rules for sprinkler head
placement.
• Sprinkler heads spaced closer than 6 ft. apart must be baffled.
• Modifications involving 20 or more sprinkler heads require hydrostatic test and
system isolation if necessary.
• For dry pipe and double interlock preaction systems in addition to the standard
hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24
hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the
24 hours shall be corrected.
All code references are NFPA 13, 2010 Edition.
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Seatac Lighting
4439 S. 134th PI
Permit No.: 08-S-041
Date: February 15, 2008
Reviewer: Al Metzler
Fire Protection Project Coordinator
(206)575-4407
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the last length of
pipe but within 20' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40 ' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-02, section 9.6.2.6.2 (e).
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
All references are NFPA 13, 2007 Edition.
1
m -DLL
-
PLAN REVIEW #1
6021 12th Street East
Suite 200
Tacoma, WA 98424
Phone: (253) 922-0446
Fax: (253) 922-0896
February 9th, 2008
Coco Fire Protection
15000 Woodinville -Redmond Road North East
Suite #B-800
Woodinville, Wa 98072
Phone: (425) 686-6300
Fax: (425) 827-4784
Attention: Brian Schulze
Project Name: Seatac Lighting TI Space
Project #: 208-032
Dear Brian:
The fire protection sprinkler system tenant improvement shop drawing (dated January 30th, 2008) and
equipment submittals for the above named project have been reviewed. The material submitted is approved,
provided the following comments are incorporated into the drawings and the updated sets are submitted to the
City of Tukwila for their review and approval. The 2007 edition of N.F.P.A. #13 was used as the basis of this
review.
Drawing Comments:
1. Sheet 1 of 1: Section 22.1.3(32) of the 2007 Edition of N.F.P.A. #13 requires a graphical scale
to be provided for all plans and a scale is not associated with the "Lighting/Reflected Ceiling
Plan".
2. Sheet 1 of 1: The H.V.A.C. supply grille locations are not indicated on the "Lighting/Reflected
Ceiling Plan". All pendent sprinkler heads that are placed within 2'-6" of an H.V.A.C. supply
grille shall either be relocate outside of this "zone of influence" or replaced with ordinary
temperature rated sprinkler heads, in accordance with N.F.P.A. #13.
3. Sheet 1 of 1: General Note #10 references the 2002 Edition of N.F.P.A. #25. The fire
protection sprinkler system contractor shall verify that the City of Tukwila does not require
compliance with the current code editions, which would be the 2008 Edition of N.F.P.A. #25.
Receiving an acceptance letter for the drawings does not relieve the contractor from meeting the requirements
of the Authority Having Jurisdiction, and N.F.P.A during the installation. Please feel free to call if you wish to
discuss any of these issues in more depth. Thank you for your time.
Sincerely,
gzec Otemedumii
Fred Blanchard F.P.E.
B.C.E. Engineers, Inc.
6021 12`h Street East Suite #200
Tacoma, Wa. 98424
Phone: (253) 922-0446
Fax: (253) 922-0896
Plan Review Page 1
•
!4
:••••••: COSCO
•••••••• Fire Protection
FIRE PROTECTION AND LIFE SAFETY SPECIALISTS
License No: COSCOFP1IONM
WASHINGTON OFFICE
Monday, February 11, 2008
To: City of Tukwila
6200 Southcenter Blvd.
Tukwila, WA. 98188
Attn: Mr. Al Metzler
Project: SEATAC LIGHTING TI SPACE
4439 SOUTH 134TH PL
Tukwila, WA. 98168
General Permit No.
Re: Pre -Review by Fred Blanchard, PE, with BCE Engineers, Inc.
Al,
This is in response to the pre -review comments by Fred Blanchard and is intended as a supplement to
same. Fred's comments are attached at the end of this response. Each comment wiH be addressed in turn.
Drawing Comments:
1. Concur graphical scale added to plans see attached.
2. Concur note added to plan. Field to verify and perform.
3. Note #10 revised on plans see attached.
END
Any questions or comments please call.
Respectfully,
Brian Schulze
Designer
Cosco Fire Protection
15000 Woodinville -Redmond Rd, Suite B-800 Telephone: (425) 827-9654
Woodinville, Washington 98072 Facsimile: (425) 827-4784
/
/
*1 Note: A value must be entered if you have selected any NAC circuits as Aux Power.
/ '\
- Globe. Project Values.
-SILENT
Project Name: Seatac Lighting TI Standby Hours:
24
KNIGHT
Project ID: JM0801 Alarm Mins:
5
Prepared By:
Andy Stuppi Derating Factor: 1.3
5820XL Calculations
Date:
5.4.08 Voltage Drop Warning
Threshold % : 10
Panel ID:
5820XL
Model: 5820XL Add.
Fire Alarm Control Panel Max NAC Current: 3.0 Amps
Location:
Sprinkler Room
Volts: 24 VDC
Max Panel Current: 5.0 Amps
Ckt.# Circuit Name qty Current Draw
Standby Alarm
Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop
& Type 1000 Ft. One -Way Ohms EOL
5820XL
5820XL CTRL Panel 1
0.140
0.260
{
p
;Ibl
SLC -DEV
Addrsbl SLC Devices 8
0.004
0.004
5815XL
SLC Loop Expander
0.000
0.000
5860
LCD Remote Annunc 1
0.020
0.025
5824
Serial/Parallel Module
0.000
0.000
5895XL
Power Expander 0
0.000
0.000
5865-4
LED Annunciator (4G)
0.000
0.000
5865-3
LED Annunciator (3G)
0.000
r 0.000
5880
LED Driver Module
0.000
0.000
SD505-6SB
Sounder Base
0.000
0.000
SD505-6RB
Relay Base
0.000
0.000
SD -Duct
Duct Hsg w/Relay 0
0.000
0.040
5883
Relay Module
0.000
0.000
Aux Power
*1 # of NAC's Used 0
0.000
0.000
PGM -I/O #1
Notification Appl Circuit
0.000
0.300
#14 Solid
3.52
350
1.76
19.87
2.59%
PGM -I/O #2
Notification Appl Circuit
0.000
0.806
#14 Solid
2.52
390
1.97
18.82
7.77%
PGM -I/O #3
Notification Appl Circuit
0.000
i 0.856
#14 Solid
2.52
400
2.02
18.67
8.46%
PGM -I/O #4
Aux Power Circuit
0.000
1 0.000
#14 Solid
2.52
250
1.26
20.40
0.00%
PGM -UO #5
Aux Power Circuit
0.000
0.000
#14 Solid
2.52
350
1.76
20.40
0.00%
PGM -I/O #6
Aux Power Circuit
0.000
0.000
#14 Solid
21.52
125
0.63
20.40
0.00%
Total Standby Current (Amps)
0.164
2.251 Total Alarm Current (Amps)
Standby Time In Hours
24
0.083
Alarm Time In Minutes / 60 (5 Mins)
Total Standby AH Required
3.946
0.188
Total Alarm AH Required
Total Combined AH Required
4.13
Command Shortcuts
Multiply By The Derating Factor
1.30
f
Minimum Battery AmpHours Required
537
Configure Circuits 1 C Print Page
*1 Note: A value must be entered if you have selected any NAC circuits as Aux Power.
/ '\
/
/
SILT �N'I`:
KNIGHT
Circuit Configuration
Project Information
r
Project Name: Seatac Lighting TI
Prepared By: Andy Stuppi
Project ID: JM0801
Date: 5.4.08
Ckt. Number: PGM -I/O #1 Panel ID:
Ckt. Name: Notification Appl Circuit I/O Use:i
5820XL
Notification Appl Circuit •
Qty Device Current Draw Each Current Draw Total
Standby Alarm Standby Alarm
4
Gentex commander 3 strobe 15cd
0.000
0.055
0.000
0.220
1
Gentex commander 3 horn strobe 15cd
0.000
0.080
0.000
0.080
0
Gentex GEC3-24WW-110 Hom/Strobe
0.000
0.151
0.000
0.000
0
Gentex GES3-24-110 Strobe
0.000
0.136
0.000
0.000
0.165
0.000
0.000
Totals
0.000
0.300
Ckt. Number: PGM -I/O #2 Panel ID:
Ckt. Name: Notification Appl Circuit I/O Use:[Notification
5820XL
•
Appl Circuit
Qty Device Current Draw Each Current Draw Total
Standby Alarm Standby Alarm
0
Gentex commander 4 horn strobe 15cd
0.000
0.094
0.000
0.000
1
Gentex commander 4 horn strobe 75cd
0.000
0.189
0.000
0.189
2
Gentex commander 4 hom strobe 115cd
0.000
0.226
0.000
0.452
3
Gentex commander 3 strobe 15cd
0.000
0.055
0.000
0.165
0.000
0.000
0.000
Totals
0.000
0.806
Ckt. Number: PGM -I/O #3 Panel ID:
Ckt. Name: Notification Appl Circuit I/O Use::
5820XL
Notification Appl Circuit v
Qty Device Current Draw Each Current Draw Total
Standby Alarm Standby Alarm
0
Gentex commander 4 strobe 115cd
0.000
0.214
0.000
0.000
6
Gentex commander 4 horn strobe 15cd
0.000
0.094
0.000
0.564
1
Gentex commander 3 horn strobe 15cd
0.000
0.080
0.000
0.080
1
Gentex WGES WP Strb/ GB -10 Bell
0.000
0.212
0.000
0.212
0.000
0.000
Totals
0.000
0.856
Q
cv
ao
as
V)
UD N e l 7 r/rc.0 w F+-wvt-tf .
FOSTMIA PARK
y 385 - 51389 s. /33 5-r,
5151 3s— — gy97 5. /34/ ,a4
. A
Fostoria Park Building #B
4475-4485 South 134th Place
Owner:
425-828-6300
r
10
` HS
340 ALL RISERS
8"
= GONrRa t LOOP / Na. HYD2�Nn Z %4a
ALL BUILDINGS
Oct 20 2009 3:27PM FSI
rrnYTITtn
FSI Confidence Plus, Inc
1014 North St., Suite 200
Sumner, WA. 98390
253-826-0099 1 253-826-1033 Fax
www.fsicpi.com
Inspection Location: Fostoria Industrial Park
Address: 4439 S 134th PL Tukwila, WA
Contact Person: Kim Bentz Phone: 425-828-6300
253 826 1033 p.10
Protecting against
loss of property and life ...
Inspection Date: 10/6109
Site Private Service Firemain
*r
r
ACE FIRE
& SECURITY
SYSTEMS
A division of Alarm Center Inc.
4500 3rd Ave
Lacey, WA 98503
Date: 1/10/18
CITY OF TUKWILA
Community Development
6300 Southcenter Blvd., #100
Tukwila, WA. 98188
RE: Fostoria Investment Property LLC
4439 South 134th Place (Bldg. E)
Tukwila,WA. 98168
Parcel #8700200010
ACCEP
Without Comments
O As Noted in Red
O Per The Attached Letter
These plans have oee,
ention Bureau
i c�aras. Acceu:. •
• issk)n5 whicr, !,'
;�dardsanG�'-
_- ;€:quacy Oi Oes
l t`r�itlons, : eiec o e
tnls date wil! vac t
resubmitta;
- s,skewed by The Tukwila Fire
,rormance ^r, r current City
i;Ja't CV el-rdrw and
rorfze `f+o atron: • :f adopted
,F res ;r?ylhira; or the
the :.$esigner.
rr~: tnese or:irwings after
fe9terlcr: aril will require a
;uoreq nt approval
Final acceprai.ce i:. 4wt je(: ie a Gest and inspection by
The Tukwila Fife Prevention bureau.
Date: /-) `I- 18 By: /Q vi - 1 (
Ace Fire and Security Systems, a UL listed fire and security alarm Iiratallati
company, submits the following description of work to be done at the above listed location.
d maintenaac.9
Scope of Work
We will be adding an AES 7707 fire alarm communicator. Product is UL Fire and NFPA-72 compliant, and has
built-in power supply and charger. Communicator will be connected to the existing FACP. After the interconnection
is done we will test the FACP and verify the signals are being received by the Alarm Center.
Thank you for this opportunity.
Point of Contact:
Justin Fiess
CAD/Permit Lead
Ace Fire and Security
1 800 354 1555
(360)786-0404 x 6430
(360)481-4969
justin(&alarmcenterinc.com
anLs
' i rc, Pet i'i s s No.
-i,•r, s for shut
w. Wll Cr ref' r on approval.
PALO
JAls 13 201e
TUKWIL.A. F
IRE
-f+-.27/23 gz v
This proposal is not a contract nor binding until our standard form agreement is executed
and which will incorporate this proposal.
ACE Fire & Security Systems • www.reachone.com/ace
Street Address: 4500 Third Ave SE, Lacey, WA 98503
Mail Address: PO Box 3407, Lacey, WA 98509-3407
E-mail: aceareachone.com • Fax: (360)438-4244 • Phone: 1-800-354-1555
r C
m
Irrri
r- 1
‘' n
x
7
+Er CO
g !1
S �1
Ij
SEA TAC LIGHTING T.I.
wP1 umI Puce
r.Y.t. WA
eccol�� wW al
«. axa
ACCEPTED
0. Without Comments
o As Noted in Red
Cl Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau fr, : _ ,r,forrriance with current City
standards. Accep4 7,,., ; „: ': ro errors and
omissions which 00 violations of adopted
standards and ordinx„ ,c,°: . so.ansibliity for the
3dequacy of design rests Wily ;N th the designer.
additions, deletions or revisions to these drawings after
this date will void this acceptance and will require a
resubmittal of revised drawings read suosequent approv, '
Final acceptance Is subject to field test and Inspection t
The Tukwila Fire Prevention Bureau.
Date: 7-30-N By: AlAi J 1
is ad
give this Fire Permit No.
nd exact adds for shut-
down or restoration approval.
NOTICE
A, completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the test is
FIELD DEMO EXIST((t�—
DROP.
t_ I9-31ZAFF-,
£OFFICE
43'40 1/2"
15'-5 1/2"
20'-0"
7'-10"
(ram
8
VALMSFIZIESHIS
Storage
Closet 4Tgazt 4a28
Hall. to
Warehouse
34'-4"
NO WORK IN EXISTING
WAREHOUSE
Offic
V,1DO1,) 70157
SAN111'( W060
GST Z - !
ALL TH(EI D ROD
HANGER I N&
I
FIELD
"TJL" WOOD JOIST
Conference
Room
SAMMY °SIDEWINDER'
MODEL 'SWG-20'
FOR WOOD
ALL THREAD ROD
HANGER RING
'TJL' WOOD JOIST
':TJL" WOOD JOIST
SAMMY 'SIDEWINDE
MODEL 'SWG-20'
FOR WOOD
3/8' ALL THREAD R
'TJL' W❑❑D JOIST
HANGER RING
ALL Al f" IJVERS TAT EXCEED 240 PROVIDE
HAMAERP
ALL PENDEN-T SPRINKLER HEADS THAT ARE PLACED k (THIN a -
OF AN HIV A►G SUPPL`( GRILLE SMALL E-ITI-IER DE RELOCATE DUTSIDE
OF THIS ZONE OF INFLUENCE OR REPL4L. WITH ZNITER 11FI-)IATE
TEMP S P IZ I N f K LER HEADS.
a 1ri7
H E\ J LI Ni=
NEV.] CEU...IH6-
FLCQOR
Conference Room
12'-7 1/2"
O
N
SEGTIc i
SECTIO:
EXISTING
BUILDING SHELL
NO WORK
!/
LEGAL DESCRIPTION
If IOSTOUA GARDW TBS LOT OFTUICWBA SNORT FLAT NO 7s44SS
KIICORDING NO/004140301 SDISATDAS.TR Sir 17 sOSTORIA CARDERS TRS
LISSFOR CONY TOCOAFPS7S111I a AFn01C10&TORUTZAF15T11570FOR
BW Y. MORE MILT DAT- TOR SD LOTS BEG SWCORLOT 1f THS 044411
17LOFTALGRUN MGR SO 1311H ST TRS1L1G7011S110FTALGSIMONOFS
13STBSTTIM 4144-17 ES27.31 VTALG SDSELV LN OFLOT11TO HILT COR SD
TAT ICTBN 41.1541O/ M ORTALGNII.Y[N SDLOT 14111S 414447 W MMOFT
TRIMLY IRO FTALG ARC CRT TORO? RAD ISS.101 PTRADFTH 4I.44.57ETWu
C/A 11.11.15 TNN 174441W MUTT SD LOT 11173 4&1503W 13S FT
ALG SDNiLY W LOT If TO COR COMMON TOLOTS If & 17TRCONT113.P7 FT
ALCNILYLNTAT I7THS 1!57.67 W 4011/FTALG SLY MQ( RE7.00ATWSO
LORDS' 7ONWLYLN IAT 17TES 41-4437 W 521 'TALC SONWLYTNOFLOT 17
TOO.YMCN S 13STHSTTTI S7S1MQ4O PTALG SDNILYMCN S IIMST
TBS S1S1W2 W NSNMal OF &TALC TFSD S 13STRSTTHS 45444SLOX FT
ALG NELY MGN SD S I3STH ST TO FOB
opier suppl es
cabine
❑
Without Comments
❑ AsNotedlnRed
IX Per The Attached Letter
i nese plans have been reviewed by The Tukwila Fire
Prevention Bureau for conforrnar,ce with current city
standards. Acceptance is v ble t to errors and •
emissions which do not :authorize violations of adopted
= tancarcls and ons -.The respon ibi= ty for the
adequacy of the des gr;er.
the e drawings atter
Gate 6t✓1 void'require a
resubmittal ofrevised v``ar.'. for subsequent approval.
Final acceptance is subject to field test and inspection by
The Tukwila Fire Prevention Bureau.
Date: D-') S" 0 2 By: S I
16'-l"
Because of increased demand our
inspectors' schedules are booked 3-7
days ahead. Therefore you will need
to. call 206-575-4407 or email.
fireinsprequest@ci.tukwilaewa.us to
schedule your inspections a minimum
of 48, hours in fiance of the y:,ite you
want an inspection
TUKWILA FIRE DEPARTMENT
Please call: 575-440Z
and give this job
No. 0'-S- O`I l
and exact address for shut.
down or restoration approval;
Server
Room
CLE
\-TES.
SECTION ,A
FILE CO
r
0
(1)DDITDNOPARAD70
SPACES
ilraflatE
(7) SXISTNGPARKA*
SPACES
/COSTA* MCC
(4216)
AREA OF WORK
SEE SHEET A2
(5)
SPA
PARKING
j14443 15.55$ S,F.
Emma WAREHOUSE
(11.3,2
30,271 S.F.
ONE STORY
CONCRETE TILT -UP
CONSTRUCTION
BUILDING
IT'iI� 1 ACES EXISTING
04439 14 713 S.F
I cO
SITE PLAN
1.- 20'42'
1.-
�l
W
W
1. c4,,9, <-=7j''D 5,11/46t4:6111 1,'- DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF N.F.P.A. 1 3 ORDINARY HAZARD MAX SPACING 130 SQ. FT...
2. COSCO POINT OF CONNECTION IS AT EXIST BUILDING SHELL SYSTEM OUTLETS ON FLOOR MAIN AS SHOWN ON THESE PLANS.
3. ALL PAINTING OF FIRE SPRINKLER PIPING (IF REQ) TO BE DONE BY OTHERS .
4. ALL WIRING BY OTHER.
5. ALL MATERIAL 15 NEW U.L. LISTED AND MEETS THE REQUIREMENTS OF THE TUKWILA FIRE DEPT.
G. OWNER. IS RESPONSIBLE TO. ASSURE THAT STRUCTURE AS IT IS SHOWN ON CONTRACT DRAWINGS CAN
ADEQUATELY SUPPORT ALL FIRE SPRINKLER PIPING LOADS. NO AUXILIARY DEVICES OR ATTACHMENTS
SHALL BE PROVIDED BY COSCO TO SUPPLIMENT TIE STRUCTURE TO ACCOMODATE FIRE SPRINKLER
7. OWNER 15 RESPONSIBLE TO PROVIDE ADEQUATE HEAT TO MAINTAIN 40 DEG. F. MINIMUM AT ALL TIMES YEAR ROUND.
S. SPRINKLER HEAD LOCATIONS INDICATED ON THESE DRAWINGS ARE NOT INTENDED TO BE "CENTER OF TILE(' HEAD PLACEMENT:
9. COSCO ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE OR
CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIEDOR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE
EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO.
10. OWNER 15 RESPONSIBLE TO ARRANGE FOR THE PERIODIC INSPECTION, TESTING AND MAINTENANCE OF THESE FIRE SPRINKLER
SYSTEMS (N ACCORDANCE WITH THE MINIMUM REQUIREMENTS Or17TO'I•= T3KWi?,A BY QUALIFIED PERSONNEL COMMENCING
AFTER WARRANTY PERIOD HAS EXPIRED. THE. MRM THAT DESIGNED AND INSTALLED THIS SYSTEM IS BEST QUALIFIED TO PROVIDE
THE ONGOING LONGTERM TESTING, MAINTENANCE AND SERVICING OF THIS SYSTEM(S).
**"" FIELD NOTES **•****
1) THREADED PIPE FROM 1" THRU 2" SIZE TO BE SCH. 40 STD. WALL PIPE (IMPORT).
2) GROOVED END PIPE FROM 2 1/2" THRU 811 TO BE SCH. 10 (IMPORT).
3) ALL GROOVED COUPLING ARE TO BE "RIGID" TYPE U.N.O. (IMPORT).
4) ALL THREADED FITTINGS ARE 300# CLASS D.I. (IMPORT).
• FIELD/NOTES
,-� EXISTING PIPE
NEW PIPE
f EXISTING HEAD
Q_ NEW HEAD
44-i°7441 efteo
c.Tus`
s'�" e
Daniel MIcLZI
391-37-0576
Ail
i74,/
-4400
6 -RA PH (GAL SCALE
O� 41 B 1!. I‘,/
SCALE 1/41= 11-6'
l�E M FT* D37 ---- 11:41Gl PAID
PII ♦ F: \C E l..� 2. 2 D �}�Ja�' 1 .�3 1 2
TAX �v 2 0Q{ �tn Tukwila Fire
�ZSlee4
/ 5 /hQ -s-8q
/13 ter/ -
Z
0
W
s
a
c
DESCRIPTION
0
z
g
0 —.
1-m
5z
re
col 401
4.2
us
0
SPRINKLER HEAD LEGEND :
MOD F1 FR SSP REC..
APPROVALS BY:
wh
imh
CV a
r 4- En
0 w
CA 14
od
o
j • 1-4 z
44
LU
ix 8
os
cV
s2 0
o
o
www.coscofire.com
0
•
co
SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE • ANCHORAGE
9,5
LU s4
—J
—J
0
V)
ce
Lu
UJ
0
LU
LLI
LLI
DRAWN BY : BRIAN SCHULZE
JOB NO.
25KS— 7896
SHEET NO.
EXIT
n l\I RAMP
NIC
NIC
z
2X1" MT, FACING
DOWN (TYP) 39-8112"
p
- N
1
SIMINIIIMISIEN ,,
MEM El= NO= MEI MOW NNW MEM ran
NIC ..-,
NOT FULL HEIGHT WALLS OVER HEAD/
UPRIGHTS NOT OBSTRUCTED (TYP) —
4'-0" FLEX HEAD
CEILING
VIKING
MODEL VK -302 QR
SEMI—RECESSED PENDENT
1"
PER PLAN
FLEX DROP
NIC
NIC
8"
1
-6
N
11
2X1" MT, FACING
TO SIDE (TYP)
MINN —wirm
0 9'-1
N
11
CN
2X1" MT, FACING
TO SIDE (TYP)
NIC
1
-6
4
P1
P1
e
N
110191111
N
\N
-8
CUT IN NEWH ARMOVER 8c
DROP IN EXISTING: SPRIG UP
PARTIAL FIRE SPRINKLER LAN
NIC
1 /4"=1'=0"
EXIST. LINE OR MAIN
NEW MECH TEE W/1" OUTLET
ETAIL TYP.
NO SCALE
01 234 5
WOOD PURLIN
SAMMY "SUPERSCREW"
MODEL "GST -20"
FOR WOOD
ALL THREAD ROD
HANGER RING
10
SAMMY HANGER DETAIL
NO SCALE
20
4
WOOD PURLIN
3/8" LAG BOLT (2)
*NOTES*
1 . INSTALLATION SHALL CONFORM TO N.F.P.A. PI-1AMPI-1LET- 13, AND CITY OF TUKWILA REQUIREMENTS:
2. ALL ADDED MATERIALS TO BE NEW AND U.L. APPROVED.
3. PIPE: ALL PIPE I AND TO BE BLACK THREADABLE THINWALL STEEL PIPE.
4. FITTINGS: ALL FITTINGS TO BE THREADED I " OR 2- I /2X 1" MECHANICAL TEES.
5. PAINTING OF PIPE AND PROTECTION OF SPRINKLER HEADS FROM PAINT 15 BY OTHERS.
6. ALL NEW HEADS ARE ORDINARY HAZARD, MAX SPACING 15 130 SQ. FT. PER N.F.P.A. 13 $ CITY OF TUKWILA.
7. ALL ELECTRICAL WIRING AND CONDUIT 15 BY OTHERS.
8. ALL NEW HEADS ARE QUICK RESPONSE.
9. ALL HANGERS TO HANG TO WOOD STRUCTURAL MEMBERS.
10. COSCO FIRE PROTECTION ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION
PERFORMANCE OR CURRENT CODE COMPLIANCE OF ANY EXISTING FIRE PROTECTION SYSTEM ON SITE
EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO FIRE PROTECTION.
I I . BUILDING OWNER AND TENANT ARE RESPONSIBLE FOR PROVIDING 40 DEGREE HEAT OR GREATER AT ALL TIMES
WHERE WET TYPE FIRE PROTECTION SYSTEMS HAVE BEEN INSTALLED.
Pae
1 2. COSCO 15 ADDING 12 NEW QR SEMI RECESSED PENDENT HEADS IN THE NEW OFFICE SPACE THAT 15
EXTENDING INTO THE EXISTING WAREHOUSE SPACE.
13. HARD PIPE ARMOVERS TO FLEX DROPS FROM EXISTING BRANCH LINES.
14. EXISTING FIRE SPRINKLER SYSTEM IS A WET GRID WITH 8" MAINS AND 2-1/2" GRIDLINES. EXISTING UPRIGHT HEADS
SPACED APPROX. 8'X 12' FOR TYPICAL SPACING OF 96 SQ. FT. AND A MAX SPACING OF 100 SQUARE FEET.
15. EXISTING FIRE SPRINKLER SYSTEM WAS SEISMICALLY UPGRADED PER THE 2008 CITY OF TUKWILA INSPECTION
RECORD #D07-449 CONTACT PERSON: SHAWN.
SYM30LS/ABREVIATIO\
in1 WM Man 11191111111 EU
S:
MECHANICAL TEE/THREADED
PLUG.
HANGER
- FLEX DROP 4'-O"
- EXISTING SPRINKLER PIPE
NEW SPRINKLER PIPE
0 OO - EXISTING UPRIGHTS
DOUBLE NUT
1-5/8" SLOTTED STRUT
ALL THREAD ROD
HANGER RING
STRUT HANGER DETAIL
NO SCALE
COUPLING
TUKWILA FIRE DEPARTT- r fr
tease caII 2O6-575-4fiO7 and
give this Fire Permit Iva.
Jti-S��i3
exact address for la --
dl e or restoration a vzli.
WithouIt: Cornrn nts
As Noted in P..i,:d
Per The h't%!;acr1 d Letter.
These plans have i:::- r I reviewed by The Tukwila Fire
-''rrvention Bureau tor cr iformance with current City
sr ndards. AcCepnnce is subject to errors and
omissions which do or :-3Ijthorize violations of adopted
_.-zndards and ord3n; i':•:�. The responsibility for the
equacy of design :::-1 totally with he designer.
. c$ tions, deietiol F.= or:: v ;ions to these drawings after
• date viii void i:1); cc eptarlce and will require a
:•esubniittal cfi F visee. ;,ravvings for subsequent approval.
''!nal acceptance is subject to field test and inspection by
-ale Tukwila Fire Prevention Bureau.
•ore: — A - I LI By:
U
rrrrrrrrrrrrrrrrrra
�rrr„errr®r STATE Y
WASHINGTON 0
CERTIFICATE OF COMPETENCY M
1 FIRE PROTECTION SPRINKLER SVS?EMS
1 .
I Al Smith
14951-0192-C Levet 3
1 COSCO Fire Protection, Inc.
COSCO. 10NM
Signature — WW.,..'r
KEY PLAN
SUBMITTAL PLAN 1-17-14
NO. DESCRIPTION
DATE
SPRINKLER HEAD LEGEND :
SYMBOL
S/N
ORIFICE
NPT
K -FACT.
HEAD
FINISH
PLATE
FINISH
TEMP.
QUAN.
VIKING QR RECESSED PENDENT
VK -302
1/2'
1/2'
5.6
CHROME
CHROME
155°
12
APPROVALS BY:
TUKWILA FIRE DEPARTMENT
TOTAL SPRINKLERS
THIS SHEET
12
. 00000e.
• 000000•
. "00 ° •
Fire Protection
FIRE PROTECTION AND LIFE SAFETY SPECIALISTS
WASHINGTON OFFICE
4308 South 131st Place
Tukwila, Washington 98168
call (425) 686-6300 • fax (425) 827-7474
SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE
www.coscofire.com
License No:
COSCOFP1 IONM
PROJECT
:SEATAC LIGHTING
4439 S 134TH PLACE
TUKWILA,WA
PAID
JAN 17 2014
CONTRACT WITH:
COSCO FIRE PROTECTION
4308S 131TS PL
TUKWILA,WA
TUKWILA FIRE
i/-27/1(
�U3'
DRAWING TI1l.E
FIRE SPRINKLER TI
DATE :
1-17-14
SCALE : 1/4"=1'-0"
DRAWN BY : MARTIN TRAICOFF
JOB "5SS8317
SHEET NO.
FP -1
0
PARKING SUMMARY FOR
BUILDING E
Figure 18-7 Tukwila Zoning code
Office:. 3 per 1,000 s.f. of floor area
Warehouse: 1 per 2,000 s,f of floor area
Building E:
30,271 s.f. total
4443 E 15,558 total; 4,216 office, 11,342
warehouse
4443 9E 14713 total; proposed 5,565 (existing
5,216) office, 9,148 ehous
Currently there • e 49 parking spaces
to Building E on ct 17
adjacent
Parking as required for proposed square
footage and uses:
4,216+5,565. = 9,781 s.f office/ 1000 = 9.781 x
3 = 29.343 spaces required for office
11,342+9,148=20,490 s.f. warehouse / 2,000 =
10.245 x 1= 10.245 spaces required for
warehouse
Total: 29343 + 10.245 = 39.588 spaces
required.
39 required spaces is less
spaces, therefore proposed p
requirements.
LEGAL DESCRIPTION
16 FOSTORIA GARDEN TRS LOT 3 OF TUKWILA SHORT PLAT NO 79 -26 -SS
RECORDING NO 8004240503 SD PLAT DAF - TR 16 & 17 FOSTORIA GARDENS TRS
LESS POR CONY TO CO AF #5721821 & AF #1006280 & TO STATE AF #5712570 FOR
HWY - MORE PRTLY DAF - POR SD LOTS BEG SW COR LOT 16 TH S 45-44-45 E
172.63 FT ALG NELY MGN SO 135TH ST TH S 66-16-10 E 104.10 FT ALG SD MGN OF S
135TH ST TH N 41-44-57 E 827.31 FT ALG SD SELY LN OF LOT 16 TO NELY COR SD
LOT 16 TH N 48-15-03 W 61.40 FT ALG NELY LN SD LOT 16 TH S 41-44-57 W 19.50 FT
TH NWLY 68.65 FT ALG ARC CRV TO RGT RAD 185.80 FT RAD PT N 41-44-57 E THRU
C/A 21-10-15 TH N 27-04-48. W 19.26 FT TO NELY LN SD LOT 16 TH N 48-15-03 W 125 FT
ALG SD NELY LN LOT 16 TO COR COMMON TO LOTS 16 & 17 TH CONT 115.97 FT
ALG NELY LN LOT 17 TH S 89-57-57 W 208.18 FT ALG SLY MGN RELOCATED SO
133RD ST TO NWLY LN LOT 17 TH S 41-44-57 W 521 FT ALG SD NWLY LN OF LOT 17
TO NLY MGN S 135TH ST TH S 29-18-21 E 91.43 FT ALG SD NELY MGN S 135TH ST
TH S 05-51-32 W 196.92 FT ALG ELY MGN OF SD S 135 TH ST TH S 45-44-45 E 69.35 FT
ALG NELY MGN SD S 135TH ST TO POB
0
--------•— ----•—• S48'15'03'E—
241.42'
/
t/.
) EXI
SOUTH 134TII PLA
-- -- -- -ow. ao
--- - - . -•,-- -- --..—. ---270 ►
r
(7) EXISTING PARKING
SPACES
EXISTING PARI
SPACES
1
1 1 1 1
L._ -_J
(2) EXIST,
QUIRED FOR
OFFICE
ASEE'SHEET A4
EXISTING OFFICE
(4216)
AREA OF WORK
SEE SHEET A2
(OF.4
0csi
(2) EXIST. 3'-0" X 6'-8"
EXITS(1 REQ'D.) FOR
_WAREHOUSE
_SEE';HEET A4
CONCRE
30,271 S.F.
ONE STORY
CONCRETE TILT -UP
CONSTRUCTION
BUILDING
ACES EXISTING
#44391°4,713 S.F ,
PROPOSED -WAREHOUSE
NO WORK_,
EXISTING WAREHOUSE
9,497 S.F.
4,13, W �..
58.36,
"= 20'-0"
- «-
-
(15)
IS
GP
QA z% p► S r
RKING
SPACES
780
L
►
'', ..,,� - of
v
tmi
(18) EXISTING PARKING SPACES
(5) EXISITING PARKING
SPACES
E-3
S,48915'03." W
5847'
BUILDING D
21,346 S.F. TOTAL
(5,745 OFFICE, 15,601 WAREHOUSE)
ONE STORY
CONCRETE TILT -UP
CONSTRUCTION
BUILDING
49 PARKING SPACES EXISTING
DEVICE LEGEND
trle
DESCRIPTION
SYM.
NOTES
QTY. DESCRIPTION
SYM.
NOTES
QTY. DESCRIPTION
dB
M
-_ 11I48°30'00"W
115,00' --
A completed, signed, Tukwila
Fire Departrtient Pre-test
Certificate must be presented
to the Inspector prior to
Commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
In a Re -inspection Fee and
errninaiion of the testing.
Because of increased demand ottr
inspectors' schedules are booked 3-7
days ahead. Therefore, you will need
to call 206-575=4407 or email
fireinsdrequestOci.tukwiia.0 a.us tO
schedule your inspections a minimum
of 48 hours in advance of the date you
want an inspection.
d;Ys� 1A4144}
r ani yySlail
ria#»t6}8
��_a31�rrr
IPJ"''' ..
Ilpli�p�''1�
��....pNiliP;if�4li�f�8 .,
0
Without Comments
As Noted In Red
Per The Attached Letter
i haaa plans have been reviewed by The Tukwila Fire
Piavention Bureau for conformance with current city
standards. Acceptance is subject to errors and
otiissions which do not authorize violations of adopted
stantieras and ordinances. The responsibility for the
adequacy of design rests totally with the design.
Additions, deletions or revisions to these drawing Ater
Itis date will void this. acceptance and will require a
itt=t4libTriiltal of ,revised dna =isms for edaroequei t AFRraval.
tai i ?its Itertolitit taniinAp i neliy
t' 1 t� �1" li 3f IGe Rita eat[tt7,'4 Buzau
em.. - I
ASIS ( Z
SYM.
NOTES
QTY.
TOTAL THIS SHEET
2085 108th Ave E
Edgewood, WA 98372
(877) 209-5545
www.av-fire.com
Lic # AVFIRSE952PM
PROJECT:
v I•N: �'tr:�iiiAlt.�R
Opo
TUKWILA FIRE DEPARTMEN1
Please call: 575.4407
and give this job
No. Df6-'` It 1
and exact address for shut'
down or restoration approval:
SEA TAC Lic hti nc TI
4439 S 134th Pf'
Tukwila, WA 98168
CONTRACT WITH:
JV COP & SO\
7612 113th ST E
Puyallup, WA 98373
1 si 2008
Tukwila Fire
,.<s '3I/77
z
0
w
z
w
CONTRACTOR:
DESIGNER:
AS
DATE:
As Noted
SCALE:
As Noted
OCUPANCY:
AHJ
CITY OF TUKWILA
JOB #
SHEET #
Site
7
z
SD-FACP
EXIST. RAMP
SLOPES DN 15" TOTAL
LANDING CONT.
Ti
/ I-iANDRWIL
SPRINK RM
U
WAREHOUSE
OFFICE
0
15cd
n
6
- SPRINKLER FLOW
7
- SPRINKLER FLOW
8
- SPRINKLER TAMPERS
Storage
Closet
15cd
EXISTING
WAREHOUSE
NO WORK
(45° max)
1
Hall t
Wareh•
se
a
Jim's
Office
OLCKT1
5 cd
5
TO FACP
15 cd
Confere'
Room
Station
TO FACP
CKT 3
conf. table
TO FACP
CKT 2
EXIT
r
IQI
LJ
onference Room
75 cd
Station
3
Recep. & Wa
Station
4
Station
5
tation
tation
7
AEIStatio
8
110cd
Employee Lounge
115cd
copier
coder supplies
L& cabinetry
11,5
n
15
Server
Rooin
Station
13
Station
9
LTJ
101
FIRE ALARM PLAN
SCALE: 1/8" =1'-0"
CLE
z
O
z
CONTRACTOR:
DEVICE LEGEND
DESCRIPTION
SYM.
NOTES
QTY.
DESCRIPTION
SYM.
NOTES
QTY.
DESCRIPTION
SYM.
NOTES
QTY.
10" BELL
B
GENTEX GB -10/24
1
FAC P
FACP
SILENT KNIGHT 5820XL
1
SMOKE DETECTOR — PHOTO
SILENT KNIGHT
SD 505 APS
1
STROBE — WEATHER PROOF
GENTEX WGES
1
HORN STROBE — CEILING MT
ti
GENTEX
COMMANDER 4
4
HORN STROBE — WALL MT
ti
GENTEX
COMMANDER 3
1
MONITOR MODULE
SILENT KNIGHT
SD 500 MIM
3
ANNUNCIATOR
ANN
SILENT KNIGHT — 5860
1
STROBE — WALL MT
GENTEX
COMMANDER 3
10
STROBE — CEILING MT
GENTEX
COMMANDER 4
1
PULL STATION
P
SILENT KNIGHT
SD -500
4
TOTAL THIS SHEET
49
ire
Security & Electric
2085 108th Ave E
Edgewood, WA 98372
(877) 209-5545
www.av-fire.com
Lic # AVFIRSE952PM
PROJECT:
SEA TAC Li htinc TI
4439 S 134th Pr
Tukwila, WA 98168
CONTRACT WITH:
JV COMP (Sc SO\
7612 113th ST E
Puyallup, WA 98373
DESIGNER:
AS
DATE:
4/8/08
SCALE:
1 /8"=1'-0"
OCUPANCY:
GROUP A
AHJ
CITY OF TUKWILA
JOB #
SHEET # FA -1 of 1
4439 S 134TH PL BLDG #E
ASSOCIATED PERMITS
18-F-024
14-F-160
08-F-119
14-S-013
08-S-041
SITE LOCATION
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.: 2613200084
Site Address: 4439 SOUTH 134TH PL Tukwila , Wa Suite Number: A, Floor:
Tenant Name: S EATAC LIGHTING New Tenant? ❑ - Yes ® - No
Property Owner's Name: FO5TOR69 "kflc 11.5 t% C . L. G
Mailing Address:
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: Martin Traicoff
Company Name: Cosco Fire Protection
Day Telephone: 206-438-3376
Mailing Address: 4308 S 131ST PL TUKW I LA , WA 98168
City State Zip
E-mail Address: MTRAICOFF@COSCOFIRE . COM Fax Number:
Valuation of Project (contractor's bid price): $ 3,500
Scope of Work (please provide detailed information): Add 12 Pendent heads in office extension
in to existing warehouse space.
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER
0 • AU - 1 RIZED
Signature: i%/ Date: 147/9
Print Name: Ma Traicoff Day Telephone: 206-438-3376
Plan Permit App.doc
5/14/10 TFD FP Form 8
41310,44
SITE LOCATION
CITY OF TUKWILA
FIRE MARSHAL'S OFFICE
206-575-4407
F tit
FIRE PROTECTION SYSTEMS PERMIT APPLICATI
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
Eft
/39/4.- King Co. Assessor's Tax No.:
Site Address: 1'/ 31 S. p1- Suite Number: * Floor:
Tenant Name: Sew To.e . L 104 i Y1C1 T. 1 New Tenant? ❑ - Yes ig - No
Property Owner's Name: FS J'\ ?COQC.C'(�N e -S
Mailing Address: 161)0 S Z(t?i''- SI— SO ` \" 1' I /it 1/0/UC, w qgoo‘
City
CONTACT PERSON -if there are questions about the submittal.
Name: 3i.4(\ 61 i ZIY�_yc i•
Company Name: Fri' kZVI_ 0. - �Cz c4jk
State Zip
Day Telephone:p.s3- 566 3
Mailing Address:
E-mail Address: �CIS4-i
Zrt, klo<1-Se th/G. Lo yvl
City Stat, e� Zip
Fax Number li 6_ 163 — 7 •,G6\
Total number of new/relocated devices or sprinkler heads:
Valuation of Project (contractor's bid price): $ ysd
Scope of Work (please provide detailed information): A� � h Zun� L�f C
X
1/bral (6,12k, pLe..
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWL ER I ' -- • RIZED AGENT:
Sign..•
Plan Permit App.doc
6/4/14
Date: 7M/�.y
Day Telephone: 3- 3 S - Sc>
TFD FP Form 8
44
IMRE
SITE LOCATION
CITY OF TUKWILA
FIRE MARSHAL'S OFFICE
206-575-4407
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.: R7Rff17flflfll O
Site Address: 4439 SOUTH 134TH PL. (BLDG. E), TUKWILA, WA 98168 Suite Number: Floor:
Tenant Name: FOSTORIA INVESTMENT PROPERTY LLC
Property Owner's Name:FOSTORIA INVESTMENT PROPERTY
New Tenant? ❑ - Yes ® - No
Mailing Address: 15100 SE 38TH STREET #792 BELLEVUE WA 98006
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: JUSTIN FIESS Day Telephone:(360) 491-6320/
(360) 481-4969
CompanyName:ALARM CENTER, INC.
Mailing Address:PO BOX 3407 LACEY WA 98509
City State Zip
E-mail Address: justin@alarmcenterinc.com Fax Number:(360) 438-4244
Contractor's City of Tukwila Business License number: BUS -0992830
Total number of new/relocated devices or sprinkler heads: 1
Valuation of Project (contractor's bid price): $ 1,495.00
Scope of Work (please provide detailed information): INSTALL NEW A.E.S. FIRE ALARM COMMUNICATOR AND
CONNECT TO EXISTING FACP.
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name: JUSTIN FIESS
Plan Permit App.doc
Date: 01/12/2018
Day Telephone: (360) 481-4969
8/22/14 TFD FP Foim 8
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Seatac Lighting
4439 S 134th PI
Permit No.: 14-S-013
Date: January 28, 2014
Reviewer: Al Metzler
Fire Protection Project Coordinator
(206) 575-4407 option # 2 (Inspection Requests)
(206) 971-8718 (Plan Review Questions)
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the last length of
pipe but within 6' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40 ' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2 for pipe size 2 1/2 inches and larger.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-02, section 9.6.2.6.2 (e).
• Ceilings used for flex drop attachments shall comply with ASTM C 635 and
ASTM C 636 per section 9.2.1.3.3.2.
• Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a
suspended ceiling, a hanger(s) attached to the structure shall be required to
ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3).
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
• Comply with obstructed/non-obstructed construction rules for sprinkler head
placement.
• Sprinkler heads spaced closer than 6 ft. apart must be baffled.
• Modifications involving 20 or more sprinkler heads require hydrostatic test and
system isolation if necessary.
• For dry pipe and double interlock preaction systems in addition to the standard
hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24
hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the
24 hours shall be corrected.
All code references are NFPA 13, 2010 Edition.
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Seatac Lighting
4439 S. 134th PI
Permit No.: 08-S-041
Date: February 15, 2008
Reviewer: Al Metzler
Fire Protection Project Coordinator
(206)575-4407
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the last length of
pipe but within 20' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40 ' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-02, section 9.6.2.6.2 (e).
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
All references are NFPA 13, 2007 Edition.
1
m -DLL
-
PLAN REVIEW #1
6021 12th Street East
Suite 200
Tacoma, WA 98424
Phone: (253) 922-0446
Fax: (253) 922-0896
February 9th, 2008
Coco Fire Protection
15000 Woodinville -Redmond Road North East
Suite #B-800
Woodinville, Wa 98072
Phone: (425) 686-6300
Fax: (425) 827-4784
Attention: Brian Schulze
Project Name: Seatac Lighting TI Space
Project #: 208-032
Dear Brian:
The fire protection sprinkler system tenant improvement shop drawing (dated January 30th, 2008) and
equipment submittals for the above named project have been reviewed. The material submitted is approved,
provided the following comments are incorporated into the drawings and the updated sets are submitted to the
City of Tukwila for their review and approval. The 2007 edition of N.F.P.A. #13 was used as the basis of this
review.
Drawing Comments:
1. Sheet 1 of 1: Section 22.1.3(32) of the 2007 Edition of N.F.P.A. #13 requires a graphical scale
to be provided for all plans and a scale is not associated with the "Lighting/Reflected Ceiling
Plan".
2. Sheet 1 of 1: The H.V.A.C. supply grille locations are not indicated on the "Lighting/Reflected
Ceiling Plan". All pendent sprinkler heads that are placed within 2'-6" of an H.V.A.C. supply
grille shall either be relocate outside of this "zone of influence" or replaced with ordinary
temperature rated sprinkler heads, in accordance with N.F.P.A. #13.
3. Sheet 1 of 1: General Note #10 references the 2002 Edition of N.F.P.A. #25. The fire
protection sprinkler system contractor shall verify that the City of Tukwila does not require
compliance with the current code editions, which would be the 2008 Edition of N.F.P.A. #25.
Receiving an acceptance letter for the drawings does not relieve the contractor from meeting the requirements
of the Authority Having Jurisdiction, and N.F.P.A during the installation. Please feel free to call if you wish to
discuss any of these issues in more depth. Thank you for your time.
Sincerely,
gzec Otemedumii
Fred Blanchard F.P.E.
B.C.E. Engineers, Inc.
6021 12`h Street East Suite #200
Tacoma, Wa. 98424
Phone: (253) 922-0446
Fax: (253) 922-0896
Plan Review Page 1
•
!4
:••••••: COSCO
•••••••• Fire Protection
FIRE PROTECTION AND LIFE SAFETY SPECIALISTS
License No: COSCOFP1IONM
WASHINGTON OFFICE
Monday, February 11, 2008
To: City of Tukwila
6200 Southcenter Blvd.
Tukwila, WA. 98188
Attn: Mr. Al Metzler
Project: SEATAC LIGHTING TI SPACE
4439 SOUTH 134TH PL
Tukwila, WA. 98168
General Permit No.
Re: Pre -Review by Fred Blanchard, PE, with BCE Engineers, Inc.
Al,
This is in response to the pre -review comments by Fred Blanchard and is intended as a supplement to
same. Fred's comments are attached at the end of this response. Each comment wiH be addressed in turn.
Drawing Comments:
1. Concur graphical scale added to plans see attached.
2. Concur note added to plan. Field to verify and perform.
3. Note #10 revised on plans see attached.
END
Any questions or comments please call.
Respectfully,
Brian Schulze
Designer
Cosco Fire Protection
15000 Woodinville -Redmond Rd, Suite B-800 Telephone: (425) 827-9654
Woodinville, Washington 98072 Facsimile: (425) 827-4784
/
/
*1 Note: A value must be entered if you have selected any NAC circuits as Aux Power.
/ '\
- Globe. Project Values.
-SILENT
Project Name: Seatac Lighting TI Standby Hours:
24
KNIGHT
Project ID: JM0801 Alarm Mins:
5
Prepared By:
Andy Stuppi Derating Factor: 1.3
5820XL Calculations
Date:
5.4.08 Voltage Drop Warning
Threshold % : 10
Panel ID:
5820XL
Model: 5820XL Add.
Fire Alarm Control Panel Max NAC Current: 3.0 Amps
Location:
Sprinkler Room
Volts: 24 VDC
Max Panel Current: 5.0 Amps
Ckt.# Circuit Name qty Current Draw
Standby Alarm
Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop
& Type 1000 Ft. One -Way Ohms EOL
5820XL
5820XL CTRL Panel 1
0.140
0.260
{
p
;Ibl
SLC -DEV
Addrsbl SLC Devices 8
0.004
0.004
5815XL
SLC Loop Expander
0.000
0.000
5860
LCD Remote Annunc 1
0.020
0.025
5824
Serial/Parallel Module
0.000
0.000
5895XL
Power Expander 0
0.000
0.000
5865-4
LED Annunciator (4G)
0.000
0.000
5865-3
LED Annunciator (3G)
0.000
r 0.000
5880
LED Driver Module
0.000
0.000
SD505-6SB
Sounder Base
0.000
0.000
SD505-6RB
Relay Base
0.000
0.000
SD -Duct
Duct Hsg w/Relay 0
0.000
0.040
5883
Relay Module
0.000
0.000
Aux Power
*1 # of NAC's Used 0
0.000
0.000
PGM -I/O #1
Notification Appl Circuit
0.000
0.300
#14 Solid
3.52
350
1.76
19.87
2.59%
PGM -I/O #2
Notification Appl Circuit
0.000
0.806
#14 Solid
2.52
390
1.97
18.82
7.77%
PGM -I/O #3
Notification Appl Circuit
0.000
i 0.856
#14 Solid
2.52
400
2.02
18.67
8.46%
PGM -I/O #4
Aux Power Circuit
0.000
1 0.000
#14 Solid
2.52
250
1.26
20.40
0.00%
PGM -UO #5
Aux Power Circuit
0.000
0.000
#14 Solid
2.52
350
1.76
20.40
0.00%
PGM -I/O #6
Aux Power Circuit
0.000
0.000
#14 Solid
21.52
125
0.63
20.40
0.00%
Total Standby Current (Amps)
0.164
2.251 Total Alarm Current (Amps)
Standby Time In Hours
24
0.083
Alarm Time In Minutes / 60 (5 Mins)
Total Standby AH Required
3.946
0.188
Total Alarm AH Required
Total Combined AH Required
4.13
Command Shortcuts
Multiply By The Derating Factor
1.30
f
Minimum Battery AmpHours Required
537
Configure Circuits 1 C Print Page
*1 Note: A value must be entered if you have selected any NAC circuits as Aux Power.
/ '\
/
/
SILT �N'I`:
KNIGHT
Circuit Configuration
Project Information
r
Project Name: Seatac Lighting TI
Prepared By: Andy Stuppi
Project ID: JM0801
Date: 5.4.08
Ckt. Number: PGM -I/O #1 Panel ID:
Ckt. Name: Notification Appl Circuit I/O Use:i
5820XL
Notification Appl Circuit •
Qty Device Current Draw Each Current Draw Total
Standby Alarm Standby Alarm
4
Gentex commander 3 strobe 15cd
0.000
0.055
0.000
0.220
1
Gentex commander 3 horn strobe 15cd
0.000
0.080
0.000
0.080
0
Gentex GEC3-24WW-110 Hom/Strobe
0.000
0.151
0.000
0.000
0
Gentex GES3-24-110 Strobe
0.000
0.136
0.000
0.000
0.165
0.000
0.000
Totals
0.000
0.300
Ckt. Number: PGM -I/O #2 Panel ID:
Ckt. Name: Notification Appl Circuit I/O Use:[Notification
5820XL
•
Appl Circuit
Qty Device Current Draw Each Current Draw Total
Standby Alarm Standby Alarm
0
Gentex commander 4 horn strobe 15cd
0.000
0.094
0.000
0.000
1
Gentex commander 4 horn strobe 75cd
0.000
0.189
0.000
0.189
2
Gentex commander 4 hom strobe 115cd
0.000
0.226
0.000
0.452
3
Gentex commander 3 strobe 15cd
0.000
0.055
0.000
0.165
0.000
0.000
0.000
Totals
0.000
0.806
Ckt. Number: PGM -I/O #3 Panel ID:
Ckt. Name: Notification Appl Circuit I/O Use::
5820XL
Notification Appl Circuit v
Qty Device Current Draw Each Current Draw Total
Standby Alarm Standby Alarm
0
Gentex commander 4 strobe 115cd
0.000
0.214
0.000
0.000
6
Gentex commander 4 horn strobe 15cd
0.000
0.094
0.000
0.564
1
Gentex commander 3 horn strobe 15cd
0.000
0.080
0.000
0.080
1
Gentex WGES WP Strb/ GB -10 Bell
0.000
0.212
0.000
0.212
0.000
0.000
Totals
0.000
0.856
Q
cv
ao
as
V)
UD N e l 7 r/rc.0 w F+-wvt-tf .
FOSTMIA PARK
y 385 - 51389 s. /33 5-r,
5151 3s— — gy97 5. /34/ ,a4
. A
Fostoria Park Building #B
4475-4485 South 134th Place
Owner:
425-828-6300
r
10
` HS
340 ALL RISERS
8"
= GONrRa t LOOP / Na. HYD2�Nn Z %4a
ALL BUILDINGS
Oct 20 2009 3:27PM FSI
rrnYTITtn
FSI Confidence Plus, Inc
1014 North St., Suite 200
Sumner, WA. 98390
253-826-0099 1 253-826-1033 Fax
www.fsicpi.com
Inspection Location: Fostoria Industrial Park
Address: 4439 S 134th PL Tukwila, WA
Contact Person: Kim Bentz Phone: 425-828-6300
253 826 1033 p.10
Protecting against
loss of property and life ...
Inspection Date: 10/6109
Site Private Service Firemain
*r
r
ACE FIRE
& SECURITY
SYSTEMS
A division of Alarm Center Inc.
4500 3rd Ave
Lacey, WA 98503
Date: 1/10/18
CITY OF TUKWILA
Community Development
6300 Southcenter Blvd., #100
Tukwila, WA. 98188
RE: Fostoria Investment Property LLC
4439 South 134th Place (Bldg. E)
Tukwila,WA. 98168
Parcel #8700200010
ACCEP
Without Comments
O As Noted in Red
O Per The Attached Letter
These plans have oee,
ention Bureau
i c�aras. Acceu:. •
• issk)n5 whicr, !,'
;�dardsanG�'-
_- ;€:quacy Oi Oes
l t`r�itlons, : eiec o e
tnls date wil! vac t
resubmitta;
- s,skewed by The Tukwila Fire
,rormance ^r, r current City
i;Ja't CV el-rdrw and
rorfze `f+o atron: • :f adopted
,F res ;r?ylhira; or the
the :.$esigner.
rr~: tnese or:irwings after
fe9terlcr: aril will require a
;uoreq nt approval
Final acceprai.ce i:. 4wt je(: ie a Gest and inspection by
The Tukwila Fife Prevention bureau.
Date: /-) `I- 18 By: /Q vi - 1 (
Ace Fire and Security Systems, a UL listed fire and security alarm Iiratallati
company, submits the following description of work to be done at the above listed location.
d maintenaac.9
Scope of Work
We will be adding an AES 7707 fire alarm communicator. Product is UL Fire and NFPA-72 compliant, and has
built-in power supply and charger. Communicator will be connected to the existing FACP. After the interconnection
is done we will test the FACP and verify the signals are being received by the Alarm Center.
Thank you for this opportunity.
Point of Contact:
Justin Fiess
CAD/Permit Lead
Ace Fire and Security
1 800 354 1555
(360)786-0404 x 6430
(360)481-4969
justin(&alarmcenterinc.com
anLs
' i rc, Pet i'i s s No.
-i,•r, s for shut
w. Wll Cr ref' r on approval.
PALO
JAls 13 201e
TUKWIL.A. F
IRE
-f+-.27/23 gz v
This proposal is not a contract nor binding until our standard form agreement is executed
and which will incorporate this proposal.
ACE Fire & Security Systems • www.reachone.com/ace
Street Address: 4500 Third Ave SE, Lacey, WA 98503
Mail Address: PO Box 3407, Lacey, WA 98509-3407
E-mail: aceareachone.com • Fax: (360)438-4244 • Phone: 1-800-354-1555
r C
m
Irrri
r- 1
‘' n
x
7
+Er CO
g !1
S �1
Ij
SEA TAC LIGHTING T.I.
wP1 umI Puce
r.Y.t. WA
eccol�� wW al
«. axa
ACCEPTED
0. Without Comments
o As Noted in Red
Cl Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau fr, : _ ,r,forrriance with current City
standards. Accep4 7,,., ; „: ': ro errors and
omissions which 00 violations of adopted
standards and ordinx„ ,c,°: . so.ansibliity for the
3dequacy of design rests Wily ;N th the designer.
additions, deletions or revisions to these drawings after
this date will void this acceptance and will require a
resubmittal of revised drawings read suosequent approv, '
Final acceptance Is subject to field test and Inspection t
The Tukwila Fire Prevention Bureau.
Date: 7-30-N By: AlAi J 1
is ad
give this Fire Permit No.
nd exact adds for shut-
down or restoration approval.
NOTICE
A, completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the test is
FIELD DEMO EXIST((t�—
DROP.
t_ I9-31ZAFF-,
£OFFICE
43'40 1/2"
15'-5 1/2"
20'-0"
7'-10"
(ram
8
VALMSFIZIESHIS
Storage
Closet 4Tgazt 4a28
Hall. to
Warehouse
34'-4"
NO WORK IN EXISTING
WAREHOUSE
Offic
V,1DO1,) 70157
SAN111'( W060
GST Z - !
ALL TH(EI D ROD
HANGER I N&
I
FIELD
"TJL" WOOD JOIST
Conference
Room
SAMMY °SIDEWINDER'
MODEL 'SWG-20'
FOR WOOD
ALL THREAD ROD
HANGER RING
'TJL' WOOD JOIST
':TJL" WOOD JOIST
SAMMY 'SIDEWINDE
MODEL 'SWG-20'
FOR WOOD
3/8' ALL THREAD R
'TJL' W❑❑D JOIST
HANGER RING
ALL Al f" IJVERS TAT EXCEED 240 PROVIDE
HAMAERP
ALL PENDEN-T SPRINKLER HEADS THAT ARE PLACED k (THIN a -
OF AN HIV A►G SUPPL`( GRILLE SMALL E-ITI-IER DE RELOCATE DUTSIDE
OF THIS ZONE OF INFLUENCE OR REPL4L. WITH ZNITER 11FI-)IATE
TEMP S P IZ I N f K LER HEADS.
a 1ri7
H E\ J LI Ni=
NEV.] CEU...IH6-
FLCQOR
Conference Room
12'-7 1/2"
O
N
SEGTIc i
SECTIO:
EXISTING
BUILDING SHELL
NO WORK
!/
LEGAL DESCRIPTION
If IOSTOUA GARDW TBS LOT OFTUICWBA SNORT FLAT NO 7s44SS
KIICORDING NO/004140301 SDISATDAS.TR Sir 17 sOSTORIA CARDERS TRS
LISSFOR CONY TOCOAFPS7S111I a AFn01C10&TORUTZAF15T11570FOR
BW Y. MORE MILT DAT- TOR SD LOTS BEG SWCORLOT 1f THS 044411
17LOFTALGRUN MGR SO 1311H ST TRS1L1G7011S110FTALGSIMONOFS
13STBSTTIM 4144-17 ES27.31 VTALG SDSELV LN OFLOT11TO HILT COR SD
TAT ICTBN 41.1541O/ M ORTALGNII.Y[N SDLOT 14111S 414447 W MMOFT
TRIMLY IRO FTALG ARC CRT TORO? RAD ISS.101 PTRADFTH 4I.44.57ETWu
C/A 11.11.15 TNN 174441W MUTT SD LOT 11173 4&1503W 13S FT
ALG SDNiLY W LOT If TO COR COMMON TOLOTS If & 17TRCONT113.P7 FT
ALCNILYLNTAT I7THS 1!57.67 W 4011/FTALG SLY MQ( RE7.00ATWSO
LORDS' 7ONWLYLN IAT 17TES 41-4437 W 521 'TALC SONWLYTNOFLOT 17
TOO.YMCN S 13STHSTTTI S7S1MQ4O PTALG SDNILYMCN S IIMST
TBS S1S1W2 W NSNMal OF &TALC TFSD S 13STRSTTHS 45444SLOX FT
ALG NELY MGN SD S I3STH ST TO FOB
opier suppl es
cabine
❑
Without Comments
❑ AsNotedlnRed
IX Per The Attached Letter
i nese plans have been reviewed by The Tukwila Fire
Prevention Bureau for conforrnar,ce with current city
standards. Acceptance is v ble t to errors and •
emissions which do not :authorize violations of adopted
= tancarcls and ons -.The respon ibi= ty for the
adequacy of the des gr;er.
the e drawings atter
Gate 6t✓1 void'require a
resubmittal ofrevised v``ar.'. for subsequent approval.
Final acceptance is subject to field test and inspection by
The Tukwila Fire Prevention Bureau.
Date: D-') S" 0 2 By: S I
16'-l"
Because of increased demand our
inspectors' schedules are booked 3-7
days ahead. Therefore you will need
to. call 206-575-4407 or email.
fireinsprequest@ci.tukwilaewa.us to
schedule your inspections a minimum
of 48, hours in fiance of the y:,ite you
want an inspection
TUKWILA FIRE DEPARTMENT
Please call: 575-440Z
and give this job
No. 0'-S- O`I l
and exact address for shut.
down or restoration approval;
Server
Room
CLE
\-TES.
SECTION ,A
FILE CO
r
0
(1)DDITDNOPARAD70
SPACES
ilraflatE
(7) SXISTNGPARKA*
SPACES
/COSTA* MCC
(4216)
AREA OF WORK
SEE SHEET A2
(5)
SPA
PARKING
j14443 15.55$ S,F.
Emma WAREHOUSE
(11.3,2
30,271 S.F.
ONE STORY
CONCRETE TILT -UP
CONSTRUCTION
BUILDING
IT'iI� 1 ACES EXISTING
04439 14 713 S.F
I cO
SITE PLAN
1.- 20'42'
1.-
�l
W
W
1. c4,,9, <-=7j''D 5,11/46t4:6111 1,'- DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF N.F.P.A. 1 3 ORDINARY HAZARD MAX SPACING 130 SQ. FT...
2. COSCO POINT OF CONNECTION IS AT EXIST BUILDING SHELL SYSTEM OUTLETS ON FLOOR MAIN AS SHOWN ON THESE PLANS.
3. ALL PAINTING OF FIRE SPRINKLER PIPING (IF REQ) TO BE DONE BY OTHERS .
4. ALL WIRING BY OTHER.
5. ALL MATERIAL 15 NEW U.L. LISTED AND MEETS THE REQUIREMENTS OF THE TUKWILA FIRE DEPT.
G. OWNER. IS RESPONSIBLE TO. ASSURE THAT STRUCTURE AS IT IS SHOWN ON CONTRACT DRAWINGS CAN
ADEQUATELY SUPPORT ALL FIRE SPRINKLER PIPING LOADS. NO AUXILIARY DEVICES OR ATTACHMENTS
SHALL BE PROVIDED BY COSCO TO SUPPLIMENT TIE STRUCTURE TO ACCOMODATE FIRE SPRINKLER
7. OWNER 15 RESPONSIBLE TO PROVIDE ADEQUATE HEAT TO MAINTAIN 40 DEG. F. MINIMUM AT ALL TIMES YEAR ROUND.
S. SPRINKLER HEAD LOCATIONS INDICATED ON THESE DRAWINGS ARE NOT INTENDED TO BE "CENTER OF TILE(' HEAD PLACEMENT:
9. COSCO ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE OR
CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIEDOR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE
EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO.
10. OWNER 15 RESPONSIBLE TO ARRANGE FOR THE PERIODIC INSPECTION, TESTING AND MAINTENANCE OF THESE FIRE SPRINKLER
SYSTEMS (N ACCORDANCE WITH THE MINIMUM REQUIREMENTS Or17TO'I•= T3KWi?,A BY QUALIFIED PERSONNEL COMMENCING
AFTER WARRANTY PERIOD HAS EXPIRED. THE. MRM THAT DESIGNED AND INSTALLED THIS SYSTEM IS BEST QUALIFIED TO PROVIDE
THE ONGOING LONGTERM TESTING, MAINTENANCE AND SERVICING OF THIS SYSTEM(S).
**"" FIELD NOTES **•****
1) THREADED PIPE FROM 1" THRU 2" SIZE TO BE SCH. 40 STD. WALL PIPE (IMPORT).
2) GROOVED END PIPE FROM 2 1/2" THRU 811 TO BE SCH. 10 (IMPORT).
3) ALL GROOVED COUPLING ARE TO BE "RIGID" TYPE U.N.O. (IMPORT).
4) ALL THREADED FITTINGS ARE 300# CLASS D.I. (IMPORT).
• FIELD/NOTES
,-� EXISTING PIPE
NEW PIPE
f EXISTING HEAD
Q_ NEW HEAD
44-i°7441 efteo
c.Tus`
s'�" e
Daniel MIcLZI
391-37-0576
Ail
i74,/
-4400
6 -RA PH (GAL SCALE
O� 41 B 1!. I‘,/
SCALE 1/41= 11-6'
l�E M FT* D37 ---- 11:41Gl PAID
PII ♦ F: \C E l..� 2. 2 D �}�Ja�' 1 .�3 1 2
TAX �v 2 0Q{ �tn Tukwila Fire
�ZSlee4
/ 5 /hQ -s-8q
/13 ter/ -
Z
0
W
s
a
c
DESCRIPTION
0
z
g
0 —.
1-m
5z
re
col 401
4.2
us
0
SPRINKLER HEAD LEGEND :
MOD F1 FR SSP REC..
APPROVALS BY:
wh
imh
CV a
r 4- En
0 w
CA 14
od
o
j • 1-4 z
44
LU
ix 8
os
cV
s2 0
o
o
www.coscofire.com
0
•
co
SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE • ANCHORAGE
9,5
LU s4
—J
—J
0
V)
ce
Lu
UJ
0
LU
LLI
LLI
DRAWN BY : BRIAN SCHULZE
JOB NO.
25KS— 7896
SHEET NO.
EXIT
n l\I RAMP
NIC
NIC
z
2X1" MT, FACING
DOWN (TYP) 39-8112"
p
- N
1
SIMINIIIMISIEN ,,
MEM El= NO= MEI MOW NNW MEM ran
NIC ..-,
NOT FULL HEIGHT WALLS OVER HEAD/
UPRIGHTS NOT OBSTRUCTED (TYP) —
4'-0" FLEX HEAD
CEILING
VIKING
MODEL VK -302 QR
SEMI—RECESSED PENDENT
1"
PER PLAN
FLEX DROP
NIC
NIC
8"
1
-6
N
11
2X1" MT, FACING
TO SIDE (TYP)
MINN —wirm
0 9'-1
N
11
CN
2X1" MT, FACING
TO SIDE (TYP)
NIC
1
-6
4
P1
P1
e
N
110191111
N
\N
-8
CUT IN NEWH ARMOVER 8c
DROP IN EXISTING: SPRIG UP
PARTIAL FIRE SPRINKLER LAN
NIC
1 /4"=1'=0"
EXIST. LINE OR MAIN
NEW MECH TEE W/1" OUTLET
ETAIL TYP.
NO SCALE
01 234 5
WOOD PURLIN
SAMMY "SUPERSCREW"
MODEL "GST -20"
FOR WOOD
ALL THREAD ROD
HANGER RING
10
SAMMY HANGER DETAIL
NO SCALE
20
4
WOOD PURLIN
3/8" LAG BOLT (2)
*NOTES*
1 . INSTALLATION SHALL CONFORM TO N.F.P.A. PI-1AMPI-1LET- 13, AND CITY OF TUKWILA REQUIREMENTS:
2. ALL ADDED MATERIALS TO BE NEW AND U.L. APPROVED.
3. PIPE: ALL PIPE I AND TO BE BLACK THREADABLE THINWALL STEEL PIPE.
4. FITTINGS: ALL FITTINGS TO BE THREADED I " OR 2- I /2X 1" MECHANICAL TEES.
5. PAINTING OF PIPE AND PROTECTION OF SPRINKLER HEADS FROM PAINT 15 BY OTHERS.
6. ALL NEW HEADS ARE ORDINARY HAZARD, MAX SPACING 15 130 SQ. FT. PER N.F.P.A. 13 $ CITY OF TUKWILA.
7. ALL ELECTRICAL WIRING AND CONDUIT 15 BY OTHERS.
8. ALL NEW HEADS ARE QUICK RESPONSE.
9. ALL HANGERS TO HANG TO WOOD STRUCTURAL MEMBERS.
10. COSCO FIRE PROTECTION ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION
PERFORMANCE OR CURRENT CODE COMPLIANCE OF ANY EXISTING FIRE PROTECTION SYSTEM ON SITE
EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO FIRE PROTECTION.
I I . BUILDING OWNER AND TENANT ARE RESPONSIBLE FOR PROVIDING 40 DEGREE HEAT OR GREATER AT ALL TIMES
WHERE WET TYPE FIRE PROTECTION SYSTEMS HAVE BEEN INSTALLED.
Pae
1 2. COSCO 15 ADDING 12 NEW QR SEMI RECESSED PENDENT HEADS IN THE NEW OFFICE SPACE THAT 15
EXTENDING INTO THE EXISTING WAREHOUSE SPACE.
13. HARD PIPE ARMOVERS TO FLEX DROPS FROM EXISTING BRANCH LINES.
14. EXISTING FIRE SPRINKLER SYSTEM IS A WET GRID WITH 8" MAINS AND 2-1/2" GRIDLINES. EXISTING UPRIGHT HEADS
SPACED APPROX. 8'X 12' FOR TYPICAL SPACING OF 96 SQ. FT. AND A MAX SPACING OF 100 SQUARE FEET.
15. EXISTING FIRE SPRINKLER SYSTEM WAS SEISMICALLY UPGRADED PER THE 2008 CITY OF TUKWILA INSPECTION
RECORD #D07-449 CONTACT PERSON: SHAWN.
SYM30LS/ABREVIATIO\
in1 WM Man 11191111111 EU
S:
MECHANICAL TEE/THREADED
PLUG.
HANGER
- FLEX DROP 4'-O"
- EXISTING SPRINKLER PIPE
NEW SPRINKLER PIPE
0 OO - EXISTING UPRIGHTS
DOUBLE NUT
1-5/8" SLOTTED STRUT
ALL THREAD ROD
HANGER RING
STRUT HANGER DETAIL
NO SCALE
COUPLING
TUKWILA FIRE DEPARTT- r fr
tease caII 2O6-575-4fiO7 and
give this Fire Permit Iva.
Jti-S��i3
exact address for la --
dl e or restoration a vzli.
WithouIt: Cornrn nts
As Noted in P..i,:d
Per The h't%!;acr1 d Letter.
These plans have i:::- r I reviewed by The Tukwila Fire
-''rrvention Bureau tor cr iformance with current City
sr ndards. AcCepnnce is subject to errors and
omissions which do or :-3Ijthorize violations of adopted
_.-zndards and ord3n; i':•:�. The responsibility for the
equacy of design :::-1 totally with he designer.
. c$ tions, deietiol F.= or:: v ;ions to these drawings after
• date viii void i:1); cc eptarlce and will require a
:•esubniittal cfi F visee. ;,ravvings for subsequent approval.
''!nal acceptance is subject to field test and inspection by
-ale Tukwila Fire Prevention Bureau.
•ore: — A - I LI By:
U
rrrrrrrrrrrrrrrrrra
�rrr„errr®r STATE Y
WASHINGTON 0
CERTIFICATE OF COMPETENCY M
1 FIRE PROTECTION SPRINKLER SVS?EMS
1 .
I Al Smith
14951-0192-C Levet 3
1 COSCO Fire Protection, Inc.
COSCO. 10NM
Signature — WW.,..'r
KEY PLAN
SUBMITTAL PLAN 1-17-14
NO. DESCRIPTION
DATE
SPRINKLER HEAD LEGEND :
SYMBOL
S/N
ORIFICE
NPT
K -FACT.
HEAD
FINISH
PLATE
FINISH
TEMP.
QUAN.
VIKING QR RECESSED PENDENT
VK -302
1/2'
1/2'
5.6
CHROME
CHROME
155°
12
APPROVALS BY:
TUKWILA FIRE DEPARTMENT
TOTAL SPRINKLERS
THIS SHEET
12
. 00000e.
• 000000•
. "00 ° •
Fire Protection
FIRE PROTECTION AND LIFE SAFETY SPECIALISTS
WASHINGTON OFFICE
4308 South 131st Place
Tukwila, Washington 98168
call (425) 686-6300 • fax (425) 827-7474
SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE
www.coscofire.com
License No:
COSCOFP1 IONM
PROJECT
:SEATAC LIGHTING
4439 S 134TH PLACE
TUKWILA,WA
PAID
JAN 17 2014
CONTRACT WITH:
COSCO FIRE PROTECTION
4308S 131TS PL
TUKWILA,WA
TUKWILA FIRE
i/-27/1(
�U3'
DRAWING TI1l.E
FIRE SPRINKLER TI
DATE :
1-17-14
SCALE : 1/4"=1'-0"
DRAWN BY : MARTIN TRAICOFF
JOB "5SS8317
SHEET NO.
FP -1
0
PARKING SUMMARY FOR
BUILDING E
Figure 18-7 Tukwila Zoning code
Office:. 3 per 1,000 s.f. of floor area
Warehouse: 1 per 2,000 s,f of floor area
Building E:
30,271 s.f. total
4443 E 15,558 total; 4,216 office, 11,342
warehouse
4443 9E 14713 total; proposed 5,565 (existing
5,216) office, 9,148 ehous
Currently there • e 49 parking spaces
to Building E on ct 17
adjacent
Parking as required for proposed square
footage and uses:
4,216+5,565. = 9,781 s.f office/ 1000 = 9.781 x
3 = 29.343 spaces required for office
11,342+9,148=20,490 s.f. warehouse / 2,000 =
10.245 x 1= 10.245 spaces required for
warehouse
Total: 29343 + 10.245 = 39.588 spaces
required.
39 required spaces is less
spaces, therefore proposed p
requirements.
LEGAL DESCRIPTION
16 FOSTORIA GARDEN TRS LOT 3 OF TUKWILA SHORT PLAT NO 79 -26 -SS
RECORDING NO 8004240503 SD PLAT DAF - TR 16 & 17 FOSTORIA GARDENS TRS
LESS POR CONY TO CO AF #5721821 & AF #1006280 & TO STATE AF #5712570 FOR
HWY - MORE PRTLY DAF - POR SD LOTS BEG SW COR LOT 16 TH S 45-44-45 E
172.63 FT ALG NELY MGN SO 135TH ST TH S 66-16-10 E 104.10 FT ALG SD MGN OF S
135TH ST TH N 41-44-57 E 827.31 FT ALG SD SELY LN OF LOT 16 TO NELY COR SD
LOT 16 TH N 48-15-03 W 61.40 FT ALG NELY LN SD LOT 16 TH S 41-44-57 W 19.50 FT
TH NWLY 68.65 FT ALG ARC CRV TO RGT RAD 185.80 FT RAD PT N 41-44-57 E THRU
C/A 21-10-15 TH N 27-04-48. W 19.26 FT TO NELY LN SD LOT 16 TH N 48-15-03 W 125 FT
ALG SD NELY LN LOT 16 TO COR COMMON TO LOTS 16 & 17 TH CONT 115.97 FT
ALG NELY LN LOT 17 TH S 89-57-57 W 208.18 FT ALG SLY MGN RELOCATED SO
133RD ST TO NWLY LN LOT 17 TH S 41-44-57 W 521 FT ALG SD NWLY LN OF LOT 17
TO NLY MGN S 135TH ST TH S 29-18-21 E 91.43 FT ALG SD NELY MGN S 135TH ST
TH S 05-51-32 W 196.92 FT ALG ELY MGN OF SD S 135 TH ST TH S 45-44-45 E 69.35 FT
ALG NELY MGN SD S 135TH ST TO POB
0
--------•— ----•—• S48'15'03'E—
241.42'
/
t/.
) EXI
SOUTH 134TII PLA
-- -- -- -ow. ao
--- - - . -•,-- -- --..—. ---270 ►
r
(7) EXISTING PARKING
SPACES
EXISTING PARI
SPACES
1
1 1 1 1
L._ -_J
(2) EXIST,
QUIRED FOR
OFFICE
ASEE'SHEET A4
EXISTING OFFICE
(4216)
AREA OF WORK
SEE SHEET A2
(OF.4
0csi
(2) EXIST. 3'-0" X 6'-8"
EXITS(1 REQ'D.) FOR
_WAREHOUSE
_SEE';HEET A4
CONCRE
30,271 S.F.
ONE STORY
CONCRETE TILT -UP
CONSTRUCTION
BUILDING
ACES EXISTING
#44391°4,713 S.F ,
PROPOSED -WAREHOUSE
NO WORK_,
EXISTING WAREHOUSE
9,497 S.F.
4,13, W �..
58.36,
"= 20'-0"
- «-
-
(15)
IS
GP
QA z% p► S r
RKING
SPACES
780
L
►
'', ..,,� - of
v
tmi
(18) EXISTING PARKING SPACES
(5) EXISITING PARKING
SPACES
E-3
S,48915'03." W
5847'
BUILDING D
21,346 S.F. TOTAL
(5,745 OFFICE, 15,601 WAREHOUSE)
ONE STORY
CONCRETE TILT -UP
CONSTRUCTION
BUILDING
49 PARKING SPACES EXISTING
DEVICE LEGEND
trle
DESCRIPTION
SYM.
NOTES
QTY. DESCRIPTION
SYM.
NOTES
QTY. DESCRIPTION
dB
M
-_ 11I48°30'00"W
115,00' --
A completed, signed, Tukwila
Fire Departrtient Pre-test
Certificate must be presented
to the Inspector prior to
Commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
In a Re -inspection Fee and
errninaiion of the testing.
Because of increased demand ottr
inspectors' schedules are booked 3-7
days ahead. Therefore, you will need
to call 206-575=4407 or email
fireinsdrequestOci.tukwiia.0 a.us tO
schedule your inspections a minimum
of 48 hours in advance of the date you
want an inspection.
d;Ys� 1A4144}
r ani yySlail
ria#»t6}8
��_a31�rrr
IPJ"''' ..
Ilpli�p�''1�
��....pNiliP;if�4li�f�8 .,
0
Without Comments
As Noted In Red
Per The Attached Letter
i haaa plans have been reviewed by The Tukwila Fire
Piavention Bureau for conformance with current city
standards. Acceptance is subject to errors and
otiissions which do not authorize violations of adopted
stantieras and ordinances. The responsibility for the
adequacy of design rests totally with the design.
Additions, deletions or revisions to these drawing Ater
Itis date will void this. acceptance and will require a
itt=t4libTriiltal of ,revised dna =isms for edaroequei t AFRraval.
tai i ?its Itertolitit taniinAp i neliy
t' 1 t� �1" li 3f IGe Rita eat[tt7,'4 Buzau
em.. - I
ASIS ( Z
SYM.
NOTES
QTY.
TOTAL THIS SHEET
2085 108th Ave E
Edgewood, WA 98372
(877) 209-5545
www.av-fire.com
Lic # AVFIRSE952PM
PROJECT:
v I•N: �'tr:�iiiAlt.�R
Opo
TUKWILA FIRE DEPARTMEN1
Please call: 575.4407
and give this job
No. Df6-'` It 1
and exact address for shut'
down or restoration approval:
SEA TAC Lic hti nc TI
4439 S 134th Pf'
Tukwila, WA 98168
CONTRACT WITH:
JV COP & SO\
7612 113th ST E
Puyallup, WA 98373
1 si 2008
Tukwila Fire
,.<s '3I/77
z
0
w
z
w
CONTRACTOR:
DESIGNER:
AS
DATE:
As Noted
SCALE:
As Noted
OCUPANCY:
AHJ
CITY OF TUKWILA
JOB #
SHEET #
Site
7
z
SD-FACP
EXIST. RAMP
SLOPES DN 15" TOTAL
LANDING CONT.
Ti
/ I-iANDRWIL
SPRINK RM
U
WAREHOUSE
OFFICE
0
15cd
n
6
- SPRINKLER FLOW
7
- SPRINKLER FLOW
8
- SPRINKLER TAMPERS
Storage
Closet
15cd
EXISTING
WAREHOUSE
NO WORK
(45° max)
1
Hall t
Wareh•
se
a
Jim's
Office
OLCKT1
5 cd
5
TO FACP
15 cd
Confere'
Room
Station
TO FACP
CKT 3
conf. table
TO FACP
CKT 2
EXIT
r
IQI
LJ
onference Room
75 cd
Station
3
Recep. & Wa
Station
4
Station
5
tation
tation
7
AEIStatio
8
110cd
Employee Lounge
115cd
copier
coder supplies
L& cabinetry
11,5
n
15
Server
Rooin
Station
13
Station
9
LTJ
101
FIRE ALARM PLAN
SCALE: 1/8" =1'-0"
CLE
z
O
z
CONTRACTOR:
DEVICE LEGEND
DESCRIPTION
SYM.
NOTES
QTY.
DESCRIPTION
SYM.
NOTES
QTY.
DESCRIPTION
SYM.
NOTES
QTY.
10" BELL
B
GENTEX GB -10/24
1
FAC P
FACP
SILENT KNIGHT 5820XL
1
SMOKE DETECTOR — PHOTO
SILENT KNIGHT
SD 505 APS
1
STROBE — WEATHER PROOF
GENTEX WGES
1
HORN STROBE — CEILING MT
ti
GENTEX
COMMANDER 4
4
HORN STROBE — WALL MT
ti
GENTEX
COMMANDER 3
1
MONITOR MODULE
SILENT KNIGHT
SD 500 MIM
3
ANNUNCIATOR
ANN
SILENT KNIGHT — 5860
1
STROBE — WALL MT
GENTEX
COMMANDER 3
10
STROBE — CEILING MT
GENTEX
COMMANDER 4
1
PULL STATION
P
SILENT KNIGHT
SD -500
4
TOTAL THIS SHEET
49
ire
Security & Electric
2085 108th Ave E
Edgewood, WA 98372
(877) 209-5545
www.av-fire.com
Lic # AVFIRSE952PM
PROJECT:
SEA TAC Li htinc TI
4439 S 134th Pr
Tukwila, WA 98168
CONTRACT WITH:
JV COMP (Sc SO\
7612 113th ST E
Puyallup, WA 98373
DESIGNER:
AS
DATE:
4/8/08
SCALE:
1 /8"=1'-0"
OCUPANCY:
GROUP A
AHJ
CITY OF TUKWILA
JOB #
SHEET # FA -1 of 1