HomeMy WebLinkAboutPP - 4439 S 134TH PL BLDG #E - FOSTORIA PARK BUILDING #E - PERMITS AND PLANS4439 S 134TH PL BLDG #E ASSOCIATED PERMITS 18-F-024 14-F-160 08-F-119 14-S-013 08-S-041 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 2613200084 Site Address: 4439 SOUTH 134TH PL Tukwila , Wa Suite Number: A, Floor: Tenant Name: S EATAC LIGHTING New Tenant? ❑ - Yes ® - No Property Owner's Name: FO5TOR69 "kflc 11.5 t% C . L. G Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Martin Traicoff Company Name: Cosco Fire Protection Day Telephone: 206-438-3376 Mailing Address: 4308 S 131ST PL TUKW I LA , WA 98168 City State Zip E-mail Address: MTRAICOFF@COSCOFIRE . COM Fax Number: Valuation of Project (contractor's bid price): $ 3,500 Scope of Work (please provide detailed information): Add 12 Pendent heads in office extension in to existing warehouse space. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 • AU - 1 RIZED Signature: i%/ Date: 147/9 Print Name: Ma Traicoff Day Telephone: 206-438-3376 Plan Permit App.doc 5/14/10 TFD FP Form 8 41310,44 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 F tit FIRE PROTECTION SYSTEMS PERMIT APPLICATI Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Eft /39/4.- King Co. Assessor's Tax No.: Site Address: 1'/ 31 S. p1- Suite Number: * Floor: Tenant Name: Sew To.e . L 104 i Y1C1 T. 1 New Tenant? ❑ - Yes ig - No Property Owner's Name: FS J'\ ?COQC.C'(�N e -S Mailing Address: 161)0 S Z(t?i''- SI— SO ` \" 1' I /it 1/0/UC, w qgoo‘ City CONTACT PERSON -if there are questions about the submittal. Name: 3i.4(\ 61 i ZIY�_yc i• Company Name: Fri' kZVI_ 0. - �Cz c4jk State Zip Day Telephone:p.s3- 566 3 Mailing Address: E-mail Address: �CIS4-i Zrt, klo<1-Se th/G. Lo yvl City Stat, e� Zip Fax Number li 6_ 163 — 7 •,G6\ Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ ysd Scope of Work (please provide detailed information): A� � h Zun� L�f C X 1/bral (6,12k, pLe.. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWL ER I ' -- • RIZED AGENT: Sign..• Plan Permit App.doc 6/4/14 Date: 7M/�.y Day Telephone: 3- 3 S - Sc> TFD FP Form 8 44 IMRE SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: R7Rff17flflfll O Site Address: 4439 SOUTH 134TH PL. (BLDG. E), TUKWILA, WA 98168 Suite Number: Floor: Tenant Name: FOSTORIA INVESTMENT PROPERTY LLC Property Owner's Name:FOSTORIA INVESTMENT PROPERTY New Tenant? ❑ - Yes ® - No Mailing Address: 15100 SE 38TH STREET #792 BELLEVUE WA 98006 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: JUSTIN FIESS Day Telephone:(360) 491-6320/ (360) 481-4969 CompanyName:ALARM CENTER, INC. Mailing Address:PO BOX 3407 LACEY WA 98509 City State Zip E-mail Address: justin@alarmcenterinc.com Fax Number:(360) 438-4244 Contractor's City of Tukwila Business License number: BUS -0992830 Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 1,495.00 Scope of Work (please provide detailed information): INSTALL NEW A.E.S. FIRE ALARM COMMUNICATOR AND CONNECT TO EXISTING FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: JUSTIN FIESS Plan Permit App.doc Date: 01/12/2018 Day Telephone: (360) 481-4969 8/22/14 TFD FP Foim 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Seatac Lighting 4439 S 134th PI Permit No.: 14-S-013 Date: January 28, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Seatac Lighting 4439 S. 134th PI Permit No.: 08-S-041 Date: February 15, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. All references are NFPA 13, 2007 Edition. 1 m -DLL - PLAN REVIEW #1 6021 12th Street East Suite 200 Tacoma, WA 98424 Phone: (253) 922-0446 Fax: (253) 922-0896 February 9th, 2008 Coco Fire Protection 15000 Woodinville -Redmond Road North East Suite #B-800 Woodinville, Wa 98072 Phone: (425) 686-6300 Fax: (425) 827-4784 Attention: Brian Schulze Project Name: Seatac Lighting TI Space Project #: 208-032 Dear Brian: The fire protection sprinkler system tenant improvement shop drawing (dated January 30th, 2008) and equipment submittals for the above named project have been reviewed. The material submitted is approved, provided the following comments are incorporated into the drawings and the updated sets are submitted to the City of Tukwila for their review and approval. The 2007 edition of N.F.P.A. #13 was used as the basis of this review. Drawing Comments: 1. Sheet 1 of 1: Section 22.1.3(32) of the 2007 Edition of N.F.P.A. #13 requires a graphical scale to be provided for all plans and a scale is not associated with the "Lighting/Reflected Ceiling Plan". 2. Sheet 1 of 1: The H.V.A.C. supply grille locations are not indicated on the "Lighting/Reflected Ceiling Plan". All pendent sprinkler heads that are placed within 2'-6" of an H.V.A.C. supply grille shall either be relocate outside of this "zone of influence" or replaced with ordinary temperature rated sprinkler heads, in accordance with N.F.P.A. #13. 3. Sheet 1 of 1: General Note #10 references the 2002 Edition of N.F.P.A. #25. The fire protection sprinkler system contractor shall verify that the City of Tukwila does not require compliance with the current code editions, which would be the 2008 Edition of N.F.P.A. #25. Receiving an acceptance letter for the drawings does not relieve the contractor from meeting the requirements of the Authority Having Jurisdiction, and N.F.P.A during the installation. Please feel free to call if you wish to discuss any of these issues in more depth. Thank you for your time. Sincerely, gzec Otemedumii Fred Blanchard F.P.E. B.C.E. Engineers, Inc. 6021 12`h Street East Suite #200 Tacoma, Wa. 98424 Phone: (253) 922-0446 Fax: (253) 922-0896 Plan Review Page 1 • !4 :••••••: COSCO •••••••• Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS License No: COSCOFP1IONM WASHINGTON OFFICE Monday, February 11, 2008 To: City of Tukwila 6200 Southcenter Blvd. Tukwila, WA. 98188 Attn: Mr. Al Metzler Project: SEATAC LIGHTING TI SPACE 4439 SOUTH 134TH PL Tukwila, WA. 98168 General Permit No. Re: Pre -Review by Fred Blanchard, PE, with BCE Engineers, Inc. Al, This is in response to the pre -review comments by Fred Blanchard and is intended as a supplement to same. Fred's comments are attached at the end of this response. Each comment wiH be addressed in turn. Drawing Comments: 1. Concur graphical scale added to plans see attached. 2. Concur note added to plan. Field to verify and perform. 3. Note #10 revised on plans see attached. END Any questions or comments please call. Respectfully, Brian Schulze Designer Cosco Fire Protection 15000 Woodinville -Redmond Rd, Suite B-800 Telephone: (425) 827-9654 Woodinville, Washington 98072 Facsimile: (425) 827-4784 / / *1 Note: A value must be entered if you have selected any NAC circuits as Aux Power. / '\ - Globe. Project Values. -SILENT Project Name: Seatac Lighting TI Standby Hours: 24 KNIGHT Project ID: JM0801 Alarm Mins: 5 Prepared By: Andy Stuppi Derating Factor: 1.3 5820XL Calculations Date: 5.4.08 Voltage Drop Warning Threshold % : 10 Panel ID: 5820XL Model: 5820XL Add. Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: Sprinkler Room Volts: 24 VDC Max Panel Current: 5.0 Amps Ckt.# Circuit Name qty Current Draw Standby Alarm Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop & Type 1000 Ft. One -Way Ohms EOL 5820XL 5820XL CTRL Panel 1 0.140 0.260 { p ;Ibl SLC -DEV Addrsbl SLC Devices 8 0.004 0.004 5815XL SLC Loop Expander 0.000 0.000 5860 LCD Remote Annunc 1 0.020 0.025 5824 Serial/Parallel Module 0.000 0.000 5895XL Power Expander 0 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 r 0.000 5880 LED Driver Module 0.000 0.000 SD505-6SB Sounder Base 0.000 0.000 SD505-6RB Relay Base 0.000 0.000 SD -Duct Duct Hsg w/Relay 0 0.000 0.040 5883 Relay Module 0.000 0.000 Aux Power *1 # of NAC's Used 0 0.000 0.000 PGM -I/O #1 Notification Appl Circuit 0.000 0.300 #14 Solid 3.52 350 1.76 19.87 2.59% PGM -I/O #2 Notification Appl Circuit 0.000 0.806 #14 Solid 2.52 390 1.97 18.82 7.77% PGM -I/O #3 Notification Appl Circuit 0.000 i 0.856 #14 Solid 2.52 400 2.02 18.67 8.46% PGM -I/O #4 Aux Power Circuit 0.000 1 0.000 #14 Solid 2.52 250 1.26 20.40 0.00% PGM -UO #5 Aux Power Circuit 0.000 0.000 #14 Solid 2.52 350 1.76 20.40 0.00% PGM -I/O #6 Aux Power Circuit 0.000 0.000 #14 Solid 21.52 125 0.63 20.40 0.00% Total Standby Current (Amps) 0.164 2.251 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 3.946 0.188 Total Alarm AH Required Total Combined AH Required 4.13 Command Shortcuts Multiply By The Derating Factor 1.30 f Minimum Battery AmpHours Required 537 Configure Circuits 1 C Print Page *1 Note: A value must be entered if you have selected any NAC circuits as Aux Power. / '\ / / SILT �N'I`: KNIGHT Circuit Configuration Project Information r Project Name: Seatac Lighting TI Prepared By: Andy Stuppi Project ID: JM0801 Date: 5.4.08 Ckt. Number: PGM -I/O #1 Panel ID: Ckt. Name: Notification Appl Circuit I/O Use:i 5820XL Notification Appl Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 Gentex commander 3 strobe 15cd 0.000 0.055 0.000 0.220 1 Gentex commander 3 horn strobe 15cd 0.000 0.080 0.000 0.080 0 Gentex GEC3-24WW-110 Hom/Strobe 0.000 0.151 0.000 0.000 0 Gentex GES3-24-110 Strobe 0.000 0.136 0.000 0.000 0.165 0.000 0.000 Totals 0.000 0.300 Ckt. Number: PGM -I/O #2 Panel ID: Ckt. Name: Notification Appl Circuit I/O Use:[Notification 5820XL • Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0 Gentex commander 4 horn strobe 15cd 0.000 0.094 0.000 0.000 1 Gentex commander 4 horn strobe 75cd 0.000 0.189 0.000 0.189 2 Gentex commander 4 hom strobe 115cd 0.000 0.226 0.000 0.452 3 Gentex commander 3 strobe 15cd 0.000 0.055 0.000 0.165 0.000 0.000 0.000 Totals 0.000 0.806 Ckt. Number: PGM -I/O #3 Panel ID: Ckt. Name: Notification Appl Circuit I/O Use:: 5820XL Notification Appl Circuit v Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0 Gentex commander 4 strobe 115cd 0.000 0.214 0.000 0.000 6 Gentex commander 4 horn strobe 15cd 0.000 0.094 0.000 0.564 1 Gentex commander 3 horn strobe 15cd 0.000 0.080 0.000 0.080 1 Gentex WGES WP Strb/ GB -10 Bell 0.000 0.212 0.000 0.212 0.000 0.000 Totals 0.000 0.856 Q cv ao as V) UD N e l 7 r/rc.0 w F+-wvt-tf . FOSTMIA PARK y 385 - 51389 s. /33 5-r, 5151 3s— — gy97 5. /34/ ,a4 . A Fostoria Park Building #B 4475-4485 South 134th Place Owner: 425-828-6300 r 10 ` HS 340 ALL RISERS 8" = GONrRa t LOOP / Na. HYD2�Nn Z %4a ALL BUILDINGS Oct 20 2009 3:27PM FSI rrnYTITtn FSI Confidence Plus, Inc 1014 North St., Suite 200 Sumner, WA. 98390 253-826-0099 1 253-826-1033 Fax www.fsicpi.com Inspection Location: Fostoria Industrial Park Address: 4439 S 134th PL Tukwila, WA Contact Person: Kim Bentz Phone: 425-828-6300 253 826 1033 p.10 Protecting against loss of property and life ... Inspection Date: 10/6109 Site Private Service Firemain *r r ACE FIRE & SECURITY SYSTEMS A division of Alarm Center Inc. 4500 3rd Ave Lacey, WA 98503 Date: 1/10/18 CITY OF TUKWILA Community Development 6300 Southcenter Blvd., #100 Tukwila, WA. 98188 RE: Fostoria Investment Property LLC 4439 South 134th Place (Bldg. E) Tukwila,WA. 98168 Parcel #8700200010 ACCEP Without Comments O As Noted in Red O Per The Attached Letter These plans have oee, ention Bureau i c�aras. Acceu:. • • issk)n5 whicr, !,' ;�dardsanG�'- _- ;€:quacy Oi Oes l t`r�itlons, : eiec o e tnls date wil! vac t resubmitta; - s,skewed by The Tukwila Fire ,rormance ^r, r current City i;Ja't CV el-rdrw and rorfze `f+o atron: • :f adopted ,F res ;r?ylhira; or the the :.$esigner. rr~: tnese or:irwings after fe9terlcr: aril will require a ;uoreq nt approval Final acceprai.ce i:. 4wt je(: ie a Gest and inspection by The Tukwila Fife Prevention bureau. Date: /-) `I- 18 By: /Q vi - 1 ( Ace Fire and Security Systems, a UL listed fire and security alarm Iiratallati company, submits the following description of work to be done at the above listed location. d maintenaac.9 Scope of Work We will be adding an AES 7707 fire alarm communicator. Product is UL Fire and NFPA-72 compliant, and has built-in power supply and charger. Communicator will be connected to the existing FACP. After the interconnection is done we will test the FACP and verify the signals are being received by the Alarm Center. Thank you for this opportunity. Point of Contact: Justin Fiess CAD/Permit Lead Ace Fire and Security 1 800 354 1555 (360)786-0404 x 6430 (360)481-4969 justin(&alarmcenterinc.com anLs ' i rc, Pet i'i s s No. -i,•r, s for shut w. Wll Cr ref' r on approval. PALO JAls 13 201e TUKWIL.A. F IRE -f+-.27/23 gz v This proposal is not a contract nor binding until our standard form agreement is executed and which will incorporate this proposal. ACE Fire & Security Systems • www.reachone.com/ace Street Address: 4500 Third Ave SE, Lacey, WA 98503 Mail Address: PO Box 3407, Lacey, WA 98509-3407 E-mail: aceareachone.com • Fax: (360)438-4244 • Phone: 1-800-354-1555 r C m Irrri r- 1 ‘' n x 7 +Er CO g !1 S �1 Ij SEA TAC LIGHTING T.I. wP1 umI Puce r.Y.t. WA eccol�� wW al «. axa ACCEPTED 0. Without Comments o As Noted in Red Cl Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau fr, : _ ,r,forrriance with current City standards. Accep4 7,,., ; „: ': ro errors and omissions which 00 violations of adopted standards and ordinx„ ,c,°: . so.ansibliity for the 3dequacy of design rests Wily ;N th the designer. additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings read suosequent approv, ' Final acceptance Is subject to field test and Inspection t The Tukwila Fire Prevention Bureau. Date: 7-30-N By: AlAi J 1 is ad give this Fire Permit No. nd exact adds for shut- down or restoration approval. NOTICE A, completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the test is FIELD DEMO EXIST((t�— DROP. t_ I9-31ZAFF-, £OFFICE 43'40 1/2" 15'-5 1/2" 20'-0" 7'-10" (ram 8 VALMSFIZIESHIS Storage Closet 4Tgazt 4a28 Hall. to Warehouse 34'-4" NO WORK IN EXISTING WAREHOUSE Offic V,1DO1,) 70157 SAN111'( W060 GST Z - ! ALL TH(EI D ROD HANGER I N& I FIELD "TJL" WOOD JOIST Conference Room SAMMY °SIDEWINDER' MODEL 'SWG-20' FOR WOOD ALL THREAD ROD HANGER RING 'TJL' WOOD JOIST ':TJL" WOOD JOIST SAMMY 'SIDEWINDE MODEL 'SWG-20' FOR WOOD 3/8' ALL THREAD R 'TJL' W❑❑D JOIST HANGER RING ALL Al f" IJVERS TAT EXCEED 240 PROVIDE HAMAERP ALL PENDEN-T SPRINKLER HEADS THAT ARE PLACED k (THIN a - OF AN HIV A►G SUPPL`( GRILLE SMALL E-ITI-IER DE RELOCATE DUTSIDE OF THIS ZONE OF INFLUENCE OR REPL4L. WITH ZNITER 11FI-)IATE TEMP S P IZ I N f K LER HEADS. a 1ri7 H E\ J LI Ni= NEV.] CEU...IH6- FLCQOR Conference Room 12'-7 1/2" O N SEGTIc i SECTIO: EXISTING BUILDING SHELL NO WORK !/ LEGAL DESCRIPTION If IOSTOUA GARDW TBS LOT OFTUICWBA SNORT FLAT NO 7s44SS KIICORDING NO/004140301 SDISATDAS.TR Sir 17 sOSTORIA CARDERS TRS LISSFOR CONY TOCOAFPS7S111I a AFn01C10&TORUTZAF15T11570FOR BW Y. MORE MILT DAT- TOR SD LOTS BEG SWCORLOT 1f THS 044411 17LOFTALGRUN MGR SO 1311H ST TRS1L1G7011S110FTALGSIMONOFS 13STBSTTIM 4144-17 ES27.31 VTALG SDSELV LN OFLOT11TO HILT COR SD TAT ICTBN 41.1541O/ M ORTALGNII.Y[N SDLOT 14111S 414447 W MMOFT TRIMLY IRO FTALG ARC CRT TORO? RAD ISS.101 PTRADFTH 4I.44.57ETWu C/A 11.11.15 TNN 174441W MUTT SD LOT 11173 4&1503W 13S FT ALG SDNiLY W LOT If TO COR COMMON TOLOTS If & 17TRCONT113.P7 FT ALCNILYLNTAT I7THS 1!57.67 W 4011/FTALG SLY MQ( RE7.00ATWSO LORDS' 7ONWLYLN IAT 17TES 41-4437 W 521 'TALC SONWLYTNOFLOT 17 TOO.YMCN S 13STHSTTTI S7S1MQ4O PTALG SDNILYMCN S IIMST TBS S1S1W2 W NSNMal OF &TALC TFSD S 13STRSTTHS 45444SLOX FT ALG NELY MGN SD S I3STH ST TO FOB opier suppl es cabine ❑ Without Comments ❑ AsNotedlnRed IX Per The Attached Letter i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conforrnar,ce with current city standards. Acceptance is v ble t to errors and • emissions which do not :authorize violations of adopted = tancarcls and ons -.The respon ibi= ty for the adequacy of the des gr;er. the e drawings atter Gate 6t✓1 void'require a resubmittal ofrevised v``ar.'. for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: D-') S" 0 2 By: S I 16'-l" Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore you will need to. call 206-575-4407 or email. fireinsprequest@ci.tukwilaewa.us to schedule your inspections a minimum of 48, hours in fiance of the y:,ite you want an inspection TUKWILA FIRE DEPARTMENT Please call: 575-440Z and give this job No. 0'-S- O`I l and exact address for shut. down or restoration approval; Server Room CLE \-TES. SECTION ,A FILE CO r 0 (1)DDITDNOPARAD70 SPACES ilraflatE (7) SXISTNGPARKA* SPACES /COSTA* MCC (4216) AREA OF WORK SEE SHEET A2 (5) SPA PARKING j14443 15.55$ S,F. Emma WAREHOUSE (11.3,2 30,271 S.F. ONE STORY CONCRETE TILT -UP CONSTRUCTION BUILDING IT'iI� 1 ACES EXISTING 04439 14 713 S.F I cO SITE PLAN 1.- 20'42' 1.- �l W W 1. c4,,9, <-=7j''D 5,11/46t4:6111 1,'- DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF N.F.P.A. 1 3 ORDINARY HAZARD MAX SPACING 130 SQ. FT... 2. COSCO POINT OF CONNECTION IS AT EXIST BUILDING SHELL SYSTEM OUTLETS ON FLOOR MAIN AS SHOWN ON THESE PLANS. 3. ALL PAINTING OF FIRE SPRINKLER PIPING (IF REQ) TO BE DONE BY OTHERS . 4. ALL WIRING BY OTHER. 5. ALL MATERIAL 15 NEW U.L. LISTED AND MEETS THE REQUIREMENTS OF THE TUKWILA FIRE DEPT. G. OWNER. IS RESPONSIBLE TO. ASSURE THAT STRUCTURE AS IT IS SHOWN ON CONTRACT DRAWINGS CAN ADEQUATELY SUPPORT ALL FIRE SPRINKLER PIPING LOADS. NO AUXILIARY DEVICES OR ATTACHMENTS SHALL BE PROVIDED BY COSCO TO SUPPLIMENT TIE STRUCTURE TO ACCOMODATE FIRE SPRINKLER 7. OWNER 15 RESPONSIBLE TO PROVIDE ADEQUATE HEAT TO MAINTAIN 40 DEG. F. MINIMUM AT ALL TIMES YEAR ROUND. S. SPRINKLER HEAD LOCATIONS INDICATED ON THESE DRAWINGS ARE NOT INTENDED TO BE "CENTER OF TILE(' HEAD PLACEMENT: 9. COSCO ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE OR CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIEDOR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO. 10. OWNER 15 RESPONSIBLE TO ARRANGE FOR THE PERIODIC INSPECTION, TESTING AND MAINTENANCE OF THESE FIRE SPRINKLER SYSTEMS (N ACCORDANCE WITH THE MINIMUM REQUIREMENTS Or17TO'I•= T3KWi?,A BY QUALIFIED PERSONNEL COMMENCING AFTER WARRANTY PERIOD HAS EXPIRED. THE. MRM THAT DESIGNED AND INSTALLED THIS SYSTEM IS BEST QUALIFIED TO PROVIDE THE ONGOING LONGTERM TESTING, MAINTENANCE AND SERVICING OF THIS SYSTEM(S). **"" FIELD NOTES **•**** 1) THREADED PIPE FROM 1" THRU 2" SIZE TO BE SCH. 40 STD. WALL PIPE (IMPORT). 2) GROOVED END PIPE FROM 2 1/2" THRU 811 TO BE SCH. 10 (IMPORT). 3) ALL GROOVED COUPLING ARE TO BE "RIGID" TYPE U.N.O. (IMPORT). 4) ALL THREADED FITTINGS ARE 300# CLASS D.I. (IMPORT). • FIELD/NOTES ,-� EXISTING PIPE NEW PIPE f EXISTING HEAD Q_ NEW HEAD 44-i°7441 efteo c.Tus` s'�" e Daniel MIcLZI 391-37-0576 Ail i74,/ -4400 6 -RA PH (GAL SCALE O� 41 B 1!. I‘,/ SCALE 1/41= 11-6' l�E M FT* D37 ---- 11:41Gl PAID PII ♦ F: \C E l..� 2. 2 D �}�Ja�' 1 .�3 1 2 TAX �v 2 0Q{ �tn Tukwila Fire �ZSlee4 / 5 /hQ -s-8q /13 ter/ - Z 0 W s a c DESCRIPTION 0 z g 0 —. 1-m 5z re col 401 4.2 us 0 SPRINKLER HEAD LEGEND : MOD F1 FR SSP REC.. APPROVALS BY: wh imh CV a r 4- En 0 w CA 14 od o j • 1-4 z 44 LU ix 8 os cV s2 0 o o www.coscofire.com 0 • co SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE • ANCHORAGE 9,5 LU s4 —J —J 0 V) ce Lu UJ 0 LU LLI LLI DRAWN BY : BRIAN SCHULZE JOB NO. 25KS— 7896 SHEET NO. EXIT n l\I RAMP NIC NIC z 2X1" MT, FACING DOWN (TYP) 39-8112" p - N 1 SIMINIIIMISIEN ,, MEM El= NO= MEI MOW NNW MEM ran NIC ..-, NOT FULL HEIGHT WALLS OVER HEAD/ UPRIGHTS NOT OBSTRUCTED (TYP) — 4'-0" FLEX HEAD CEILING VIKING MODEL VK -302 QR SEMI—RECESSED PENDENT 1" PER PLAN FLEX DROP NIC NIC 8" 1 -6 N 11 2X1" MT, FACING TO SIDE (TYP) MINN —wirm 0 9'-1 N 11 CN 2X1" MT, FACING TO SIDE (TYP) NIC 1 -6 4 P1 P1 e N 110191111 N \N -8 CUT IN NEWH ARMOVER 8c DROP IN EXISTING: SPRIG UP PARTIAL FIRE SPRINKLER LAN NIC 1 /4"=1'=0" EXIST. LINE OR MAIN NEW MECH TEE W/1" OUTLET ETAIL TYP. NO SCALE 01 234 5 WOOD PURLIN SAMMY "SUPERSCREW" MODEL "GST -20" FOR WOOD ALL THREAD ROD HANGER RING 10 SAMMY HANGER DETAIL NO SCALE 20 4 WOOD PURLIN 3/8" LAG BOLT (2) *NOTES* 1 . INSTALLATION SHALL CONFORM TO N.F.P.A. PI-1AMPI-1LET- 13, AND CITY OF TUKWILA REQUIREMENTS: 2. ALL ADDED MATERIALS TO BE NEW AND U.L. APPROVED. 3. PIPE: ALL PIPE I AND TO BE BLACK THREADABLE THINWALL STEEL PIPE. 4. FITTINGS: ALL FITTINGS TO BE THREADED I " OR 2- I /2X 1" MECHANICAL TEES. 5. PAINTING OF PIPE AND PROTECTION OF SPRINKLER HEADS FROM PAINT 15 BY OTHERS. 6. ALL NEW HEADS ARE ORDINARY HAZARD, MAX SPACING 15 130 SQ. FT. PER N.F.P.A. 13 $ CITY OF TUKWILA. 7. ALL ELECTRICAL WIRING AND CONDUIT 15 BY OTHERS. 8. ALL NEW HEADS ARE QUICK RESPONSE. 9. ALL HANGERS TO HANG TO WOOD STRUCTURAL MEMBERS. 10. COSCO FIRE PROTECTION ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION PERFORMANCE OR CURRENT CODE COMPLIANCE OF ANY EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO FIRE PROTECTION. I I . BUILDING OWNER AND TENANT ARE RESPONSIBLE FOR PROVIDING 40 DEGREE HEAT OR GREATER AT ALL TIMES WHERE WET TYPE FIRE PROTECTION SYSTEMS HAVE BEEN INSTALLED. Pae 1 2. COSCO 15 ADDING 12 NEW QR SEMI RECESSED PENDENT HEADS IN THE NEW OFFICE SPACE THAT 15 EXTENDING INTO THE EXISTING WAREHOUSE SPACE. 13. HARD PIPE ARMOVERS TO FLEX DROPS FROM EXISTING BRANCH LINES. 14. EXISTING FIRE SPRINKLER SYSTEM IS A WET GRID WITH 8" MAINS AND 2-1/2" GRIDLINES. EXISTING UPRIGHT HEADS SPACED APPROX. 8'X 12' FOR TYPICAL SPACING OF 96 SQ. FT. AND A MAX SPACING OF 100 SQUARE FEET. 15. EXISTING FIRE SPRINKLER SYSTEM WAS SEISMICALLY UPGRADED PER THE 2008 CITY OF TUKWILA INSPECTION RECORD #D07-449 CONTACT PERSON: SHAWN. SYM30LS/ABREVIATIO\ in1 WM Man 11191111111 EU S: MECHANICAL TEE/THREADED PLUG. HANGER - FLEX DROP 4'-O" - EXISTING SPRINKLER PIPE NEW SPRINKLER PIPE 0 OO - EXISTING UPRIGHTS DOUBLE NUT 1-5/8" SLOTTED STRUT ALL THREAD ROD HANGER RING STRUT HANGER DETAIL NO SCALE COUPLING TUKWILA FIRE DEPARTT- r fr tease caII 2O6-575-4fiO7 and give this Fire Permit Iva. Jti-S��i3 exact address for la -- dl e or restoration a vzli. WithouIt: Cornrn nts As Noted in P..i,:d Per The h't%!;acr1 d Letter. These plans have i:::- r I reviewed by The Tukwila Fire -''rrvention Bureau tor cr iformance with current City sr ndards. AcCepnnce is subject to errors and omissions which do or :-3Ijthorize violations of adopted _.-zndards and ord3n; i':•:�. The responsibility for the equacy of design :::-1 totally with he designer. . c$ tions, deietiol F.= or:: v ;ions to these drawings after • date viii void i:1); cc eptarlce and will require a :•esubniittal cfi F visee. ;,ravvings for subsequent approval. ''!nal acceptance is subject to field test and inspection by -ale Tukwila Fire Prevention Bureau. •ore: — A - I LI By: U rrrrrrrrrrrrrrrrrra �rrr„errr®r STATE Y WASHINGTON 0 CERTIFICATE OF COMPETENCY M 1 FIRE PROTECTION SPRINKLER SVS?EMS 1 . I Al Smith 14951-0192-C Levet 3 1 COSCO Fire Protection, Inc. COSCO. 10NM Signature — WW.,..'r KEY PLAN SUBMITTAL PLAN 1-17-14 NO. DESCRIPTION DATE SPRINKLER HEAD LEGEND : SYMBOL S/N ORIFICE NPT K -FACT. HEAD FINISH PLATE FINISH TEMP. QUAN. VIKING QR RECESSED PENDENT VK -302 1/2' 1/2' 5.6 CHROME CHROME 155° 12 APPROVALS BY: TUKWILA FIRE DEPARTMENT TOTAL SPRINKLERS THIS SHEET 12 . 00000e. • 000000• . "00 ° • Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS WASHINGTON OFFICE 4308 South 131st Place Tukwila, Washington 98168 call (425) 686-6300 • fax (425) 827-7474 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE www.coscofire.com License No: COSCOFP1 IONM PROJECT :SEATAC LIGHTING 4439 S 134TH PLACE TUKWILA,WA PAID JAN 17 2014 CONTRACT WITH: COSCO FIRE PROTECTION 4308S 131TS PL TUKWILA,WA TUKWILA FIRE i/-27/1( �U3' DRAWING TI1l.E FIRE SPRINKLER TI DATE : 1-17-14 SCALE : 1/4"=1'-0" DRAWN BY : MARTIN TRAICOFF JOB "5SS8317 SHEET NO. FP -1 0 PARKING SUMMARY FOR BUILDING E Figure 18-7 Tukwila Zoning code Office:. 3 per 1,000 s.f. of floor area Warehouse: 1 per 2,000 s,f of floor area Building E: 30,271 s.f. total 4443 E 15,558 total; 4,216 office, 11,342 warehouse 4443 9E 14713 total; proposed 5,565 (existing 5,216) office, 9,148 ehous Currently there • e 49 parking spaces to Building E on ct 17 adjacent Parking as required for proposed square footage and uses: 4,216+5,565. = 9,781 s.f office/ 1000 = 9.781 x 3 = 29.343 spaces required for office 11,342+9,148=20,490 s.f. warehouse / 2,000 = 10.245 x 1= 10.245 spaces required for warehouse Total: 29343 + 10.245 = 39.588 spaces required. 39 required spaces is less spaces, therefore proposed p requirements. LEGAL DESCRIPTION 16 FOSTORIA GARDEN TRS LOT 3 OF TUKWILA SHORT PLAT NO 79 -26 -SS RECORDING NO 8004240503 SD PLAT DAF - TR 16 & 17 FOSTORIA GARDENS TRS LESS POR CONY TO CO AF #5721821 & AF #1006280 & TO STATE AF #5712570 FOR HWY - MORE PRTLY DAF - POR SD LOTS BEG SW COR LOT 16 TH S 45-44-45 E 172.63 FT ALG NELY MGN SO 135TH ST TH S 66-16-10 E 104.10 FT ALG SD MGN OF S 135TH ST TH N 41-44-57 E 827.31 FT ALG SD SELY LN OF LOT 16 TO NELY COR SD LOT 16 TH N 48-15-03 W 61.40 FT ALG NELY LN SD LOT 16 TH S 41-44-57 W 19.50 FT TH NWLY 68.65 FT ALG ARC CRV TO RGT RAD 185.80 FT RAD PT N 41-44-57 E THRU C/A 21-10-15 TH N 27-04-48. W 19.26 FT TO NELY LN SD LOT 16 TH N 48-15-03 W 125 FT ALG SD NELY LN LOT 16 TO COR COMMON TO LOTS 16 & 17 TH CONT 115.97 FT ALG NELY LN LOT 17 TH S 89-57-57 W 208.18 FT ALG SLY MGN RELOCATED SO 133RD ST TO NWLY LN LOT 17 TH S 41-44-57 W 521 FT ALG SD NWLY LN OF LOT 17 TO NLY MGN S 135TH ST TH S 29-18-21 E 91.43 FT ALG SD NELY MGN S 135TH ST TH S 05-51-32 W 196.92 FT ALG ELY MGN OF SD S 135 TH ST TH S 45-44-45 E 69.35 FT ALG NELY MGN SD S 135TH ST TO POB 0 --------•— ----•—• S48'15'03'E— 241.42' / t/. ) EXI SOUTH 134TII PLA -- -- -- -ow. ao --- - - . -•,-- -- --..—. ---270 ► r (7) EXISTING PARKING SPACES EXISTING PARI SPACES 1 1 1 1 1 L._ -_J (2) EXIST, QUIRED FOR OFFICE ASEE'SHEET A4 EXISTING OFFICE (4216) AREA OF WORK SEE SHEET A2 (OF.4 0csi (2) EXIST. 3'-0" X 6'-8" EXITS(1 REQ'D.) FOR _WAREHOUSE _SEE';HEET A4 CONCRE 30,271 S.F. ONE STORY CONCRETE TILT -UP CONSTRUCTION BUILDING ACES EXISTING #44391°4,713 S.F , PROPOSED -WAREHOUSE NO WORK_, EXISTING WAREHOUSE 9,497 S.F. 4,13, W �.. 58.36, "= 20'-0" - «- - (15) IS GP QA z% p► S r RKING SPACES 780 L ► '', ..,,� - of v tmi (18) EXISTING PARKING SPACES (5) EXISITING PARKING SPACES E-3 S,48915'03." W 5847' BUILDING D 21,346 S.F. TOTAL (5,745 OFFICE, 15,601 WAREHOUSE) ONE STORY CONCRETE TILT -UP CONSTRUCTION BUILDING 49 PARKING SPACES EXISTING DEVICE LEGEND trle DESCRIPTION SYM. NOTES QTY. DESCRIPTION SYM. NOTES QTY. DESCRIPTION dB M -_ 11I48°30'00"W 115,00' -- A completed, signed, Tukwila Fire Departrtient Pre-test Certificate must be presented to the Inspector prior to Commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result In a Re -inspection Fee and errninaiion of the testing. Because of increased demand ottr inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575=4407 or email fireinsdrequestOci.tukwiia.0 a.us tO schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. d;Ys� 1A4144} r ani yySlail ria#»t6}8 ��_a31�rrr IPJ"''' .. Ilpli�p�''1� ��....pNiliP;if�4li�f�8 ., 0 Without Comments As Noted In Red Per The Attached Letter i haaa plans have been reviewed by The Tukwila Fire Piavention Bureau for conformance with current city standards. Acceptance is subject to errors and otiissions which do not authorize violations of adopted stantieras and ordinances. The responsibility for the adequacy of design rests totally with the design. Additions, deletions or revisions to these drawing Ater Itis date will void this. acceptance and will require a itt=t4libTriiltal of ,revised dna =isms for edaroequei t AFRraval. tai i ?its Itertolitit taniinAp i neliy t' 1 t� �1" li 3f IGe Rita eat[tt7,'4 Buzau em.. - I ASIS ( Z SYM. NOTES QTY. TOTAL THIS SHEET 2085 108th Ave E Edgewood, WA 98372 (877) 209-5545 www.av-fire.com Lic # AVFIRSE952PM PROJECT: v I•N: �'tr:�iiiAlt.�R Opo TUKWILA FIRE DEPARTMEN1 Please call: 575.4407 and give this job No. Df6-'` It 1 and exact address for shut' down or restoration approval: SEA TAC Lic hti nc TI 4439 S 134th Pf' Tukwila, WA 98168 CONTRACT WITH: JV COP & SO\ 7612 113th ST E Puyallup, WA 98373 1 si 2008 Tukwila Fire ,.<s '3I/77 z 0 w z w CONTRACTOR: DESIGNER: AS DATE: As Noted SCALE: As Noted OCUPANCY: AHJ CITY OF TUKWILA JOB # SHEET # Site 7 z SD-FACP EXIST. RAMP SLOPES DN 15" TOTAL LANDING CONT. Ti / I-iANDRWIL SPRINK RM U WAREHOUSE OFFICE 0 15cd n 6 - SPRINKLER FLOW 7 - SPRINKLER FLOW 8 - SPRINKLER TAMPERS Storage Closet 15cd EXISTING WAREHOUSE NO WORK (45° max) 1 Hall t Wareh• se a Jim's Office OLCKT1 5 cd 5 TO FACP 15 cd Confere' Room Station TO FACP CKT 3 conf. table TO FACP CKT 2 EXIT r IQI LJ onference Room 75 cd Station 3 Recep. & Wa Station 4 Station 5 tation tation 7 AEIStatio 8 110cd Employee Lounge 115cd copier coder supplies L& cabinetry 11,5 n 15 Server Rooin Station 13 Station 9 LTJ 101 FIRE ALARM PLAN SCALE: 1/8" =1'-0" CLE z O z CONTRACTOR: DEVICE LEGEND DESCRIPTION SYM. NOTES QTY. DESCRIPTION SYM. NOTES QTY. DESCRIPTION SYM. NOTES QTY. 10" BELL B GENTEX GB -10/24 1 FAC P FACP SILENT KNIGHT 5820XL 1 SMOKE DETECTOR — PHOTO SILENT KNIGHT SD 505 APS 1 STROBE — WEATHER PROOF GENTEX WGES 1 HORN STROBE — CEILING MT ti GENTEX COMMANDER 4 4 HORN STROBE — WALL MT ti GENTEX COMMANDER 3 1 MONITOR MODULE SILENT KNIGHT SD 500 MIM 3 ANNUNCIATOR ANN SILENT KNIGHT — 5860 1 STROBE — WALL MT GENTEX COMMANDER 3 10 STROBE — CEILING MT GENTEX COMMANDER 4 1 PULL STATION P SILENT KNIGHT SD -500 4 TOTAL THIS SHEET 49 ire Security & Electric 2085 108th Ave E Edgewood, WA 98372 (877) 209-5545 www.av-fire.com Lic # AVFIRSE952PM PROJECT: SEA TAC Li htinc TI 4439 S 134th Pr Tukwila, WA 98168 CONTRACT WITH: JV COMP (Sc SO\ 7612 113th ST E Puyallup, WA 98373 DESIGNER: AS DATE: 4/8/08 SCALE: 1 /8"=1'-0" OCUPANCY: GROUP A AHJ CITY OF TUKWILA JOB # SHEET # FA -1 of 1 4439 S 134TH PL BLDG #E ASSOCIATED PERMITS 18-F-024 14-F-160 08-F-119 14-S-013 08-S-041 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 2613200084 Site Address: 4439 SOUTH 134TH PL Tukwila , Wa Suite Number: A, Floor: Tenant Name: S EATAC LIGHTING New Tenant? ❑ - Yes ® - No Property Owner's Name: FO5TOR69 "kflc 11.5 t% C . L. G Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Martin Traicoff Company Name: Cosco Fire Protection Day Telephone: 206-438-3376 Mailing Address: 4308 S 131ST PL TUKW I LA , WA 98168 City State Zip E-mail Address: MTRAICOFF@COSCOFIRE . COM Fax Number: Valuation of Project (contractor's bid price): $ 3,500 Scope of Work (please provide detailed information): Add 12 Pendent heads in office extension in to existing warehouse space. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 • AU - 1 RIZED Signature: i%/ Date: 147/9 Print Name: Ma Traicoff Day Telephone: 206-438-3376 Plan Permit App.doc 5/14/10 TFD FP Form 8 41310,44 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 F tit FIRE PROTECTION SYSTEMS PERMIT APPLICATI Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Eft /39/4.- King Co. Assessor's Tax No.: Site Address: 1'/ 31 S. p1- Suite Number: * Floor: Tenant Name: Sew To.e . L 104 i Y1C1 T. 1 New Tenant? ❑ - Yes ig - No Property Owner's Name: FS J'\ ?COQC.C'(�N e -S Mailing Address: 161)0 S Z(t?i''- SI— SO ` \" 1' I /it 1/0/UC, w qgoo‘ City CONTACT PERSON -if there are questions about the submittal. Name: 3i.4(\ 61 i ZIY�_yc i• Company Name: Fri' kZVI_ 0. - �Cz c4jk State Zip Day Telephone:p.s3- 566 3 Mailing Address: E-mail Address: �CIS4-i Zrt, klo<1-Se th/G. Lo yvl City Stat, e� Zip Fax Number li 6_ 163 — 7 •,G6\ Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ ysd Scope of Work (please provide detailed information): A� � h Zun� L�f C X 1/bral (6,12k, pLe.. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWL ER I ' -- • RIZED AGENT: Sign..• Plan Permit App.doc 6/4/14 Date: 7M/�.y Day Telephone: 3- 3 S - Sc> TFD FP Form 8 44 IMRE SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: R7Rff17flflfll O Site Address: 4439 SOUTH 134TH PL. (BLDG. E), TUKWILA, WA 98168 Suite Number: Floor: Tenant Name: FOSTORIA INVESTMENT PROPERTY LLC Property Owner's Name:FOSTORIA INVESTMENT PROPERTY New Tenant? ❑ - Yes ® - No Mailing Address: 15100 SE 38TH STREET #792 BELLEVUE WA 98006 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: JUSTIN FIESS Day Telephone:(360) 491-6320/ (360) 481-4969 CompanyName:ALARM CENTER, INC. Mailing Address:PO BOX 3407 LACEY WA 98509 City State Zip E-mail Address: justin@alarmcenterinc.com Fax Number:(360) 438-4244 Contractor's City of Tukwila Business License number: BUS -0992830 Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 1,495.00 Scope of Work (please provide detailed information): INSTALL NEW A.E.S. FIRE ALARM COMMUNICATOR AND CONNECT TO EXISTING FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: JUSTIN FIESS Plan Permit App.doc Date: 01/12/2018 Day Telephone: (360) 481-4969 8/22/14 TFD FP Foim 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Seatac Lighting 4439 S 134th PI Permit No.: 14-S-013 Date: January 28, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Seatac Lighting 4439 S. 134th PI Permit No.: 08-S-041 Date: February 15, 2008 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 20' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. All references are NFPA 13, 2007 Edition. 1 m -DLL - PLAN REVIEW #1 6021 12th Street East Suite 200 Tacoma, WA 98424 Phone: (253) 922-0446 Fax: (253) 922-0896 February 9th, 2008 Coco Fire Protection 15000 Woodinville -Redmond Road North East Suite #B-800 Woodinville, Wa 98072 Phone: (425) 686-6300 Fax: (425) 827-4784 Attention: Brian Schulze Project Name: Seatac Lighting TI Space Project #: 208-032 Dear Brian: The fire protection sprinkler system tenant improvement shop drawing (dated January 30th, 2008) and equipment submittals for the above named project have been reviewed. The material submitted is approved, provided the following comments are incorporated into the drawings and the updated sets are submitted to the City of Tukwila for their review and approval. The 2007 edition of N.F.P.A. #13 was used as the basis of this review. Drawing Comments: 1. Sheet 1 of 1: Section 22.1.3(32) of the 2007 Edition of N.F.P.A. #13 requires a graphical scale to be provided for all plans and a scale is not associated with the "Lighting/Reflected Ceiling Plan". 2. Sheet 1 of 1: The H.V.A.C. supply grille locations are not indicated on the "Lighting/Reflected Ceiling Plan". All pendent sprinkler heads that are placed within 2'-6" of an H.V.A.C. supply grille shall either be relocate outside of this "zone of influence" or replaced with ordinary temperature rated sprinkler heads, in accordance with N.F.P.A. #13. 3. Sheet 1 of 1: General Note #10 references the 2002 Edition of N.F.P.A. #25. The fire protection sprinkler system contractor shall verify that the City of Tukwila does not require compliance with the current code editions, which would be the 2008 Edition of N.F.P.A. #25. Receiving an acceptance letter for the drawings does not relieve the contractor from meeting the requirements of the Authority Having Jurisdiction, and N.F.P.A during the installation. Please feel free to call if you wish to discuss any of these issues in more depth. Thank you for your time. Sincerely, gzec Otemedumii Fred Blanchard F.P.E. B.C.E. Engineers, Inc. 6021 12`h Street East Suite #200 Tacoma, Wa. 98424 Phone: (253) 922-0446 Fax: (253) 922-0896 Plan Review Page 1 • !4 :••••••: COSCO •••••••• Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS License No: COSCOFP1IONM WASHINGTON OFFICE Monday, February 11, 2008 To: City of Tukwila 6200 Southcenter Blvd. Tukwila, WA. 98188 Attn: Mr. Al Metzler Project: SEATAC LIGHTING TI SPACE 4439 SOUTH 134TH PL Tukwila, WA. 98168 General Permit No. Re: Pre -Review by Fred Blanchard, PE, with BCE Engineers, Inc. Al, This is in response to the pre -review comments by Fred Blanchard and is intended as a supplement to same. Fred's comments are attached at the end of this response. Each comment wiH be addressed in turn. Drawing Comments: 1. Concur graphical scale added to plans see attached. 2. Concur note added to plan. Field to verify and perform. 3. Note #10 revised on plans see attached. END Any questions or comments please call. Respectfully, Brian Schulze Designer Cosco Fire Protection 15000 Woodinville -Redmond Rd, Suite B-800 Telephone: (425) 827-9654 Woodinville, Washington 98072 Facsimile: (425) 827-4784 / / *1 Note: A value must be entered if you have selected any NAC circuits as Aux Power. / '\ - Globe. Project Values. -SILENT Project Name: Seatac Lighting TI Standby Hours: 24 KNIGHT Project ID: JM0801 Alarm Mins: 5 Prepared By: Andy Stuppi Derating Factor: 1.3 5820XL Calculations Date: 5.4.08 Voltage Drop Warning Threshold % : 10 Panel ID: 5820XL Model: 5820XL Add. Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: Sprinkler Room Volts: 24 VDC Max Panel Current: 5.0 Amps Ckt.# Circuit Name qty Current Draw Standby Alarm Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop & Type 1000 Ft. One -Way Ohms EOL 5820XL 5820XL CTRL Panel 1 0.140 0.260 { p ;Ibl SLC -DEV Addrsbl SLC Devices 8 0.004 0.004 5815XL SLC Loop Expander 0.000 0.000 5860 LCD Remote Annunc 1 0.020 0.025 5824 Serial/Parallel Module 0.000 0.000 5895XL Power Expander 0 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 r 0.000 5880 LED Driver Module 0.000 0.000 SD505-6SB Sounder Base 0.000 0.000 SD505-6RB Relay Base 0.000 0.000 SD -Duct Duct Hsg w/Relay 0 0.000 0.040 5883 Relay Module 0.000 0.000 Aux Power *1 # of NAC's Used 0 0.000 0.000 PGM -I/O #1 Notification Appl Circuit 0.000 0.300 #14 Solid 3.52 350 1.76 19.87 2.59% PGM -I/O #2 Notification Appl Circuit 0.000 0.806 #14 Solid 2.52 390 1.97 18.82 7.77% PGM -I/O #3 Notification Appl Circuit 0.000 i 0.856 #14 Solid 2.52 400 2.02 18.67 8.46% PGM -I/O #4 Aux Power Circuit 0.000 1 0.000 #14 Solid 2.52 250 1.26 20.40 0.00% PGM -UO #5 Aux Power Circuit 0.000 0.000 #14 Solid 2.52 350 1.76 20.40 0.00% PGM -I/O #6 Aux Power Circuit 0.000 0.000 #14 Solid 21.52 125 0.63 20.40 0.00% Total Standby Current (Amps) 0.164 2.251 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 3.946 0.188 Total Alarm AH Required Total Combined AH Required 4.13 Command Shortcuts Multiply By The Derating Factor 1.30 f Minimum Battery AmpHours Required 537 Configure Circuits 1 C Print Page *1 Note: A value must be entered if you have selected any NAC circuits as Aux Power. / '\ / / SILT �N'I`: KNIGHT Circuit Configuration Project Information r Project Name: Seatac Lighting TI Prepared By: Andy Stuppi Project ID: JM0801 Date: 5.4.08 Ckt. Number: PGM -I/O #1 Panel ID: Ckt. Name: Notification Appl Circuit I/O Use:i 5820XL Notification Appl Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 Gentex commander 3 strobe 15cd 0.000 0.055 0.000 0.220 1 Gentex commander 3 horn strobe 15cd 0.000 0.080 0.000 0.080 0 Gentex GEC3-24WW-110 Hom/Strobe 0.000 0.151 0.000 0.000 0 Gentex GES3-24-110 Strobe 0.000 0.136 0.000 0.000 0.165 0.000 0.000 Totals 0.000 0.300 Ckt. Number: PGM -I/O #2 Panel ID: Ckt. Name: Notification Appl Circuit I/O Use:[Notification 5820XL • Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0 Gentex commander 4 horn strobe 15cd 0.000 0.094 0.000 0.000 1 Gentex commander 4 horn strobe 75cd 0.000 0.189 0.000 0.189 2 Gentex commander 4 hom strobe 115cd 0.000 0.226 0.000 0.452 3 Gentex commander 3 strobe 15cd 0.000 0.055 0.000 0.165 0.000 0.000 0.000 Totals 0.000 0.806 Ckt. Number: PGM -I/O #3 Panel ID: Ckt. Name: Notification Appl Circuit I/O Use:: 5820XL Notification Appl Circuit v Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0 Gentex commander 4 strobe 115cd 0.000 0.214 0.000 0.000 6 Gentex commander 4 horn strobe 15cd 0.000 0.094 0.000 0.564 1 Gentex commander 3 horn strobe 15cd 0.000 0.080 0.000 0.080 1 Gentex WGES WP Strb/ GB -10 Bell 0.000 0.212 0.000 0.212 0.000 0.000 Totals 0.000 0.856 Q cv ao as V) UD N e l 7 r/rc.0 w F+-wvt-tf . FOSTMIA PARK y 385 - 51389 s. /33 5-r, 5151 3s— — gy97 5. /34/ ,a4 . A Fostoria Park Building #B 4475-4485 South 134th Place Owner: 425-828-6300 r 10 ` HS 340 ALL RISERS 8" = GONrRa t LOOP / Na. HYD2�Nn Z %4a ALL BUILDINGS Oct 20 2009 3:27PM FSI rrnYTITtn FSI Confidence Plus, Inc 1014 North St., Suite 200 Sumner, WA. 98390 253-826-0099 1 253-826-1033 Fax www.fsicpi.com Inspection Location: Fostoria Industrial Park Address: 4439 S 134th PL Tukwila, WA Contact Person: Kim Bentz Phone: 425-828-6300 253 826 1033 p.10 Protecting against loss of property and life ... Inspection Date: 10/6109 Site Private Service Firemain *r r ACE FIRE & SECURITY SYSTEMS A division of Alarm Center Inc. 4500 3rd Ave Lacey, WA 98503 Date: 1/10/18 CITY OF TUKWILA Community Development 6300 Southcenter Blvd., #100 Tukwila, WA. 98188 RE: Fostoria Investment Property LLC 4439 South 134th Place (Bldg. E) Tukwila,WA. 98168 Parcel #8700200010 ACCEP Without Comments O As Noted in Red O Per The Attached Letter These plans have oee, ention Bureau i c�aras. Acceu:. • • issk)n5 whicr, !,' ;�dardsanG�'- _- ;€:quacy Oi Oes l t`r�itlons, : eiec o e tnls date wil! vac t resubmitta; - s,skewed by The Tukwila Fire ,rormance ^r, r current City i;Ja't CV el-rdrw and rorfze `f+o atron: • :f adopted ,F res ;r?ylhira; or the the :.$esigner. rr~: tnese or:irwings after fe9terlcr: aril will require a ;uoreq nt approval Final acceprai.ce i:. 4wt je(: ie a Gest and inspection by The Tukwila Fife Prevention bureau. Date: /-) `I- 18 By: /Q vi - 1 ( Ace Fire and Security Systems, a UL listed fire and security alarm Iiratallati company, submits the following description of work to be done at the above listed location. d maintenaac.9 Scope of Work We will be adding an AES 7707 fire alarm communicator. Product is UL Fire and NFPA-72 compliant, and has built-in power supply and charger. Communicator will be connected to the existing FACP. After the interconnection is done we will test the FACP and verify the signals are being received by the Alarm Center. Thank you for this opportunity. Point of Contact: Justin Fiess CAD/Permit Lead Ace Fire and Security 1 800 354 1555 (360)786-0404 x 6430 (360)481-4969 justin(&alarmcenterinc.com anLs ' i rc, Pet i'i s s No. -i,•r, s for shut w. Wll Cr ref' r on approval. PALO JAls 13 201e TUKWIL.A. F IRE -f+-.27/23 gz v This proposal is not a contract nor binding until our standard form agreement is executed and which will incorporate this proposal. ACE Fire & Security Systems • www.reachone.com/ace Street Address: 4500 Third Ave SE, Lacey, WA 98503 Mail Address: PO Box 3407, Lacey, WA 98509-3407 E-mail: aceareachone.com • Fax: (360)438-4244 • Phone: 1-800-354-1555 r C m Irrri r- 1 ‘' n x 7 +Er CO g !1 S �1 Ij SEA TAC LIGHTING T.I. wP1 umI Puce r.Y.t. WA eccol�� wW al «. axa ACCEPTED 0. Without Comments o As Noted in Red Cl Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau fr, : _ ,r,forrriance with current City standards. Accep4 7,,., ; „: ': ro errors and omissions which 00 violations of adopted standards and ordinx„ ,c,°: . so.ansibliity for the 3dequacy of design rests Wily ;N th the designer. additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings read suosequent approv, ' Final acceptance Is subject to field test and Inspection t The Tukwila Fire Prevention Bureau. Date: 7-30-N By: AlAi J 1 is ad give this Fire Permit No. nd exact adds for shut- down or restoration approval. NOTICE A, completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the test is FIELD DEMO EXIST((t�— DROP. t_ I9-31ZAFF-, £OFFICE 43'40 1/2" 15'-5 1/2" 20'-0" 7'-10" (ram 8 VALMSFIZIESHIS Storage Closet 4Tgazt 4a28 Hall. to Warehouse 34'-4" NO WORK IN EXISTING WAREHOUSE Offic V,1DO1,) 70157 SAN111'( W060 GST Z - ! ALL TH(EI D ROD HANGER I N& I FIELD "TJL" WOOD JOIST Conference Room SAMMY °SIDEWINDER' MODEL 'SWG-20' FOR WOOD ALL THREAD ROD HANGER RING 'TJL' WOOD JOIST ':TJL" WOOD JOIST SAMMY 'SIDEWINDE MODEL 'SWG-20' FOR WOOD 3/8' ALL THREAD R 'TJL' W❑❑D JOIST HANGER RING ALL Al f" IJVERS TAT EXCEED 240 PROVIDE HAMAERP ALL PENDEN-T SPRINKLER HEADS THAT ARE PLACED k (THIN a - OF AN HIV A►G SUPPL`( GRILLE SMALL E-ITI-IER DE RELOCATE DUTSIDE OF THIS ZONE OF INFLUENCE OR REPL4L. WITH ZNITER 11FI-)IATE TEMP S P IZ I N f K LER HEADS. a 1ri7 H E\ J LI Ni= NEV.] CEU...IH6- FLCQOR Conference Room 12'-7 1/2" O N SEGTIc i SECTIO: EXISTING BUILDING SHELL NO WORK !/ LEGAL DESCRIPTION If IOSTOUA GARDW TBS LOT OFTUICWBA SNORT FLAT NO 7s44SS KIICORDING NO/004140301 SDISATDAS.TR Sir 17 sOSTORIA CARDERS TRS LISSFOR CONY TOCOAFPS7S111I a AFn01C10&TORUTZAF15T11570FOR BW Y. MORE MILT DAT- TOR SD LOTS BEG SWCORLOT 1f THS 044411 17LOFTALGRUN MGR SO 1311H ST TRS1L1G7011S110FTALGSIMONOFS 13STBSTTIM 4144-17 ES27.31 VTALG SDSELV LN OFLOT11TO HILT COR SD TAT ICTBN 41.1541O/ M ORTALGNII.Y[N SDLOT 14111S 414447 W MMOFT TRIMLY IRO FTALG ARC CRT TORO? RAD ISS.101 PTRADFTH 4I.44.57ETWu C/A 11.11.15 TNN 174441W MUTT SD LOT 11173 4&1503W 13S FT ALG SDNiLY W LOT If TO COR COMMON TOLOTS If & 17TRCONT113.P7 FT ALCNILYLNTAT I7THS 1!57.67 W 4011/FTALG SLY MQ( RE7.00ATWSO LORDS' 7ONWLYLN IAT 17TES 41-4437 W 521 'TALC SONWLYTNOFLOT 17 TOO.YMCN S 13STHSTTTI S7S1MQ4O PTALG SDNILYMCN S IIMST TBS S1S1W2 W NSNMal OF &TALC TFSD S 13STRSTTHS 45444SLOX FT ALG NELY MGN SD S I3STH ST TO FOB opier suppl es cabine ❑ Without Comments ❑ AsNotedlnRed IX Per The Attached Letter i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conforrnar,ce with current city standards. Acceptance is v ble t to errors and • emissions which do not :authorize violations of adopted = tancarcls and ons -.The respon ibi= ty for the adequacy of the des gr;er. the e drawings atter Gate 6t✓1 void'require a resubmittal ofrevised v``ar.'. for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: D-') S" 0 2 By: S I 16'-l" Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore you will need to. call 206-575-4407 or email. fireinsprequest@ci.tukwilaewa.us to schedule your inspections a minimum of 48, hours in fiance of the y:,ite you want an inspection TUKWILA FIRE DEPARTMENT Please call: 575-440Z and give this job No. 0'-S- O`I l and exact address for shut. down or restoration approval; Server Room CLE \-TES. SECTION ,A FILE CO r 0 (1)DDITDNOPARAD70 SPACES ilraflatE (7) SXISTNGPARKA* SPACES /COSTA* MCC (4216) AREA OF WORK SEE SHEET A2 (5) SPA PARKING j14443 15.55$ S,F. Emma WAREHOUSE (11.3,2 30,271 S.F. ONE STORY CONCRETE TILT -UP CONSTRUCTION BUILDING IT'iI� 1 ACES EXISTING 04439 14 713 S.F I cO SITE PLAN 1.- 20'42' 1.- �l W W 1. c4,,9, <-=7j''D 5,11/46t4:6111 1,'- DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF N.F.P.A. 1 3 ORDINARY HAZARD MAX SPACING 130 SQ. FT... 2. COSCO POINT OF CONNECTION IS AT EXIST BUILDING SHELL SYSTEM OUTLETS ON FLOOR MAIN AS SHOWN ON THESE PLANS. 3. ALL PAINTING OF FIRE SPRINKLER PIPING (IF REQ) TO BE DONE BY OTHERS . 4. ALL WIRING BY OTHER. 5. ALL MATERIAL 15 NEW U.L. LISTED AND MEETS THE REQUIREMENTS OF THE TUKWILA FIRE DEPT. G. OWNER. IS RESPONSIBLE TO. ASSURE THAT STRUCTURE AS IT IS SHOWN ON CONTRACT DRAWINGS CAN ADEQUATELY SUPPORT ALL FIRE SPRINKLER PIPING LOADS. NO AUXILIARY DEVICES OR ATTACHMENTS SHALL BE PROVIDED BY COSCO TO SUPPLIMENT TIE STRUCTURE TO ACCOMODATE FIRE SPRINKLER 7. OWNER 15 RESPONSIBLE TO PROVIDE ADEQUATE HEAT TO MAINTAIN 40 DEG. F. MINIMUM AT ALL TIMES YEAR ROUND. S. SPRINKLER HEAD LOCATIONS INDICATED ON THESE DRAWINGS ARE NOT INTENDED TO BE "CENTER OF TILE(' HEAD PLACEMENT: 9. COSCO ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE OR CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIEDOR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO. 10. OWNER 15 RESPONSIBLE TO ARRANGE FOR THE PERIODIC INSPECTION, TESTING AND MAINTENANCE OF THESE FIRE SPRINKLER SYSTEMS (N ACCORDANCE WITH THE MINIMUM REQUIREMENTS Or17TO'I•= T3KWi?,A BY QUALIFIED PERSONNEL COMMENCING AFTER WARRANTY PERIOD HAS EXPIRED. THE. MRM THAT DESIGNED AND INSTALLED THIS SYSTEM IS BEST QUALIFIED TO PROVIDE THE ONGOING LONGTERM TESTING, MAINTENANCE AND SERVICING OF THIS SYSTEM(S). **"" FIELD NOTES **•**** 1) THREADED PIPE FROM 1" THRU 2" SIZE TO BE SCH. 40 STD. WALL PIPE (IMPORT). 2) GROOVED END PIPE FROM 2 1/2" THRU 811 TO BE SCH. 10 (IMPORT). 3) ALL GROOVED COUPLING ARE TO BE "RIGID" TYPE U.N.O. (IMPORT). 4) ALL THREADED FITTINGS ARE 300# CLASS D.I. (IMPORT). • FIELD/NOTES ,-� EXISTING PIPE NEW PIPE f EXISTING HEAD Q_ NEW HEAD 44-i°7441 efteo c.Tus` s'�" e Daniel MIcLZI 391-37-0576 Ail i74,/ -4400 6 -RA PH (GAL SCALE O� 41 B 1!. I‘,/ SCALE 1/41= 11-6' l�E M FT* D37 ---- 11:41Gl PAID PII ♦ F: \C E l..� 2. 2 D �}�Ja�' 1 .�3 1 2 TAX �v 2 0Q{ �tn Tukwila Fire �ZSlee4 / 5 /hQ -s-8q /13 ter/ - Z 0 W s a c DESCRIPTION 0 z g 0 —. 1-m 5z re col 401 4.2 us 0 SPRINKLER HEAD LEGEND : MOD F1 FR SSP REC.. APPROVALS BY: wh imh CV a r 4- En 0 w CA 14 od o j • 1-4 z 44 LU ix 8 os cV s2 0 o o www.coscofire.com 0 • co SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE • ANCHORAGE 9,5 LU s4 —J —J 0 V) ce Lu UJ 0 LU LLI LLI DRAWN BY : BRIAN SCHULZE JOB NO. 25KS— 7896 SHEET NO. EXIT n l\I RAMP NIC NIC z 2X1" MT, FACING DOWN (TYP) 39-8112" p - N 1 SIMINIIIMISIEN ,, MEM El= NO= MEI MOW NNW MEM ran NIC ..-, NOT FULL HEIGHT WALLS OVER HEAD/ UPRIGHTS NOT OBSTRUCTED (TYP) — 4'-0" FLEX HEAD CEILING VIKING MODEL VK -302 QR SEMI—RECESSED PENDENT 1" PER PLAN FLEX DROP NIC NIC 8" 1 -6 N 11 2X1" MT, FACING TO SIDE (TYP) MINN —wirm 0 9'-1 N 11 CN 2X1" MT, FACING TO SIDE (TYP) NIC 1 -6 4 P1 P1 e N 110191111 N \N -8 CUT IN NEWH ARMOVER 8c DROP IN EXISTING: SPRIG UP PARTIAL FIRE SPRINKLER LAN NIC 1 /4"=1'=0" EXIST. LINE OR MAIN NEW MECH TEE W/1" OUTLET ETAIL TYP. NO SCALE 01 234 5 WOOD PURLIN SAMMY "SUPERSCREW" MODEL "GST -20" FOR WOOD ALL THREAD ROD HANGER RING 10 SAMMY HANGER DETAIL NO SCALE 20 4 WOOD PURLIN 3/8" LAG BOLT (2) *NOTES* 1 . INSTALLATION SHALL CONFORM TO N.F.P.A. PI-1AMPI-1LET- 13, AND CITY OF TUKWILA REQUIREMENTS: 2. ALL ADDED MATERIALS TO BE NEW AND U.L. APPROVED. 3. PIPE: ALL PIPE I AND TO BE BLACK THREADABLE THINWALL STEEL PIPE. 4. FITTINGS: ALL FITTINGS TO BE THREADED I " OR 2- I /2X 1" MECHANICAL TEES. 5. PAINTING OF PIPE AND PROTECTION OF SPRINKLER HEADS FROM PAINT 15 BY OTHERS. 6. ALL NEW HEADS ARE ORDINARY HAZARD, MAX SPACING 15 130 SQ. FT. PER N.F.P.A. 13 $ CITY OF TUKWILA. 7. ALL ELECTRICAL WIRING AND CONDUIT 15 BY OTHERS. 8. ALL NEW HEADS ARE QUICK RESPONSE. 9. ALL HANGERS TO HANG TO WOOD STRUCTURAL MEMBERS. 10. COSCO FIRE PROTECTION ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION PERFORMANCE OR CURRENT CODE COMPLIANCE OF ANY EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY COSCO FIRE PROTECTION. I I . BUILDING OWNER AND TENANT ARE RESPONSIBLE FOR PROVIDING 40 DEGREE HEAT OR GREATER AT ALL TIMES WHERE WET TYPE FIRE PROTECTION SYSTEMS HAVE BEEN INSTALLED. Pae 1 2. COSCO 15 ADDING 12 NEW QR SEMI RECESSED PENDENT HEADS IN THE NEW OFFICE SPACE THAT 15 EXTENDING INTO THE EXISTING WAREHOUSE SPACE. 13. HARD PIPE ARMOVERS TO FLEX DROPS FROM EXISTING BRANCH LINES. 14. EXISTING FIRE SPRINKLER SYSTEM IS A WET GRID WITH 8" MAINS AND 2-1/2" GRIDLINES. EXISTING UPRIGHT HEADS SPACED APPROX. 8'X 12' FOR TYPICAL SPACING OF 96 SQ. FT. AND A MAX SPACING OF 100 SQUARE FEET. 15. EXISTING FIRE SPRINKLER SYSTEM WAS SEISMICALLY UPGRADED PER THE 2008 CITY OF TUKWILA INSPECTION RECORD #D07-449 CONTACT PERSON: SHAWN. SYM30LS/ABREVIATIO\ in1 WM Man 11191111111 EU S: MECHANICAL TEE/THREADED PLUG. HANGER - FLEX DROP 4'-O" - EXISTING SPRINKLER PIPE NEW SPRINKLER PIPE 0 OO - EXISTING UPRIGHTS DOUBLE NUT 1-5/8" SLOTTED STRUT ALL THREAD ROD HANGER RING STRUT HANGER DETAIL NO SCALE COUPLING TUKWILA FIRE DEPARTT- r fr tease caII 2O6-575-4fiO7 and give this Fire Permit Iva. Jti-S��i3 exact address for la -- dl e or restoration a vzli. WithouIt: Cornrn nts As Noted in P..i,:d Per The h't%!;acr1 d Letter. These plans have i:::- r I reviewed by The Tukwila Fire -''rrvention Bureau tor cr iformance with current City sr ndards. AcCepnnce is subject to errors and omissions which do or :-3Ijthorize violations of adopted _.-zndards and ord3n; i':•:�. The responsibility for the equacy of design :::-1 totally with he designer. . c$ tions, deietiol F.= or:: v ;ions to these drawings after • date viii void i:1); cc eptarlce and will require a :•esubniittal cfi F visee. ;,ravvings for subsequent approval. ''!nal acceptance is subject to field test and inspection by -ale Tukwila Fire Prevention Bureau. •ore: — A - I LI By: U rrrrrrrrrrrrrrrrrra �rrr„errr®r STATE Y WASHINGTON 0 CERTIFICATE OF COMPETENCY M 1 FIRE PROTECTION SPRINKLER SVS?EMS 1 . I Al Smith 14951-0192-C Levet 3 1 COSCO Fire Protection, Inc. COSCO. 10NM Signature — WW.,..'r KEY PLAN SUBMITTAL PLAN 1-17-14 NO. DESCRIPTION DATE SPRINKLER HEAD LEGEND : SYMBOL S/N ORIFICE NPT K -FACT. HEAD FINISH PLATE FINISH TEMP. QUAN. VIKING QR RECESSED PENDENT VK -302 1/2' 1/2' 5.6 CHROME CHROME 155° 12 APPROVALS BY: TUKWILA FIRE DEPARTMENT TOTAL SPRINKLERS THIS SHEET 12 . 00000e. • 000000• . "00 ° • Fire Protection FIRE PROTECTION AND LIFE SAFETY SPECIALISTS WASHINGTON OFFICE 4308 South 131st Place Tukwila, Washington 98168 call (425) 686-6300 • fax (425) 827-7474 SAN DIEGO • LOS ANGELES • FRESNO • SAN FRANCISCO • SACRAMENTO • PORTLAND • SEATTLE www.coscofire.com License No: COSCOFP1 IONM PROJECT :SEATAC LIGHTING 4439 S 134TH PLACE TUKWILA,WA PAID JAN 17 2014 CONTRACT WITH: COSCO FIRE PROTECTION 4308S 131TS PL TUKWILA,WA TUKWILA FIRE i/-27/1( �U3' DRAWING TI1l.E FIRE SPRINKLER TI DATE : 1-17-14 SCALE : 1/4"=1'-0" DRAWN BY : MARTIN TRAICOFF JOB "5SS8317 SHEET NO. FP -1 0 PARKING SUMMARY FOR BUILDING E Figure 18-7 Tukwila Zoning code Office:. 3 per 1,000 s.f. of floor area Warehouse: 1 per 2,000 s,f of floor area Building E: 30,271 s.f. total 4443 E 15,558 total; 4,216 office, 11,342 warehouse 4443 9E 14713 total; proposed 5,565 (existing 5,216) office, 9,148 ehous Currently there • e 49 parking spaces to Building E on ct 17 adjacent Parking as required for proposed square footage and uses: 4,216+5,565. = 9,781 s.f office/ 1000 = 9.781 x 3 = 29.343 spaces required for office 11,342+9,148=20,490 s.f. warehouse / 2,000 = 10.245 x 1= 10.245 spaces required for warehouse Total: 29343 + 10.245 = 39.588 spaces required. 39 required spaces is less spaces, therefore proposed p requirements. LEGAL DESCRIPTION 16 FOSTORIA GARDEN TRS LOT 3 OF TUKWILA SHORT PLAT NO 79 -26 -SS RECORDING NO 8004240503 SD PLAT DAF - TR 16 & 17 FOSTORIA GARDENS TRS LESS POR CONY TO CO AF #5721821 & AF #1006280 & TO STATE AF #5712570 FOR HWY - MORE PRTLY DAF - POR SD LOTS BEG SW COR LOT 16 TH S 45-44-45 E 172.63 FT ALG NELY MGN SO 135TH ST TH S 66-16-10 E 104.10 FT ALG SD MGN OF S 135TH ST TH N 41-44-57 E 827.31 FT ALG SD SELY LN OF LOT 16 TO NELY COR SD LOT 16 TH N 48-15-03 W 61.40 FT ALG NELY LN SD LOT 16 TH S 41-44-57 W 19.50 FT TH NWLY 68.65 FT ALG ARC CRV TO RGT RAD 185.80 FT RAD PT N 41-44-57 E THRU C/A 21-10-15 TH N 27-04-48. W 19.26 FT TO NELY LN SD LOT 16 TH N 48-15-03 W 125 FT ALG SD NELY LN LOT 16 TO COR COMMON TO LOTS 16 & 17 TH CONT 115.97 FT ALG NELY LN LOT 17 TH S 89-57-57 W 208.18 FT ALG SLY MGN RELOCATED SO 133RD ST TO NWLY LN LOT 17 TH S 41-44-57 W 521 FT ALG SD NWLY LN OF LOT 17 TO NLY MGN S 135TH ST TH S 29-18-21 E 91.43 FT ALG SD NELY MGN S 135TH ST TH S 05-51-32 W 196.92 FT ALG ELY MGN OF SD S 135 TH ST TH S 45-44-45 E 69.35 FT ALG NELY MGN SD S 135TH ST TO POB 0 --------•— ----•—• S48'15'03'E— 241.42' / t/. ) EXI SOUTH 134TII PLA -- -- -- -ow. ao --- - - . -•,-- -- --..—. ---270 ► r (7) EXISTING PARKING SPACES EXISTING PARI SPACES 1 1 1 1 1 L._ -_J (2) EXIST, QUIRED FOR OFFICE ASEE'SHEET A4 EXISTING OFFICE (4216) AREA OF WORK SEE SHEET A2 (OF.4 0csi (2) EXIST. 3'-0" X 6'-8" EXITS(1 REQ'D.) FOR _WAREHOUSE _SEE';HEET A4 CONCRE 30,271 S.F. ONE STORY CONCRETE TILT -UP CONSTRUCTION BUILDING ACES EXISTING #44391°4,713 S.F , PROPOSED -WAREHOUSE NO WORK_, EXISTING WAREHOUSE 9,497 S.F. 4,13, W �.. 58.36, "= 20'-0" - «- - (15) IS GP QA z% p► S r RKING SPACES 780 L ► '', ..,,� - of v tmi (18) EXISTING PARKING SPACES (5) EXISITING PARKING SPACES E-3 S,48915'03." W 5847' BUILDING D 21,346 S.F. TOTAL (5,745 OFFICE, 15,601 WAREHOUSE) ONE STORY CONCRETE TILT -UP CONSTRUCTION BUILDING 49 PARKING SPACES EXISTING DEVICE LEGEND trle DESCRIPTION SYM. NOTES QTY. DESCRIPTION SYM. NOTES QTY. DESCRIPTION dB M -_ 11I48°30'00"W 115,00' -- A completed, signed, Tukwila Fire Departrtient Pre-test Certificate must be presented to the Inspector prior to Commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result In a Re -inspection Fee and errninaiion of the testing. Because of increased demand ottr inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575=4407 or email fireinsdrequestOci.tukwiia.0 a.us tO schedule your inspections a minimum of 48 hours in advance of the date you want an inspection. d;Ys� 1A4144} r ani yySlail ria#»t6}8 ��_a31�rrr IPJ"''' .. Ilpli�p�''1� ��....pNiliP;if�4li�f�8 ., 0 Without Comments As Noted In Red Per The Attached Letter i haaa plans have been reviewed by The Tukwila Fire Piavention Bureau for conformance with current city standards. Acceptance is subject to errors and otiissions which do not authorize violations of adopted stantieras and ordinances. The responsibility for the adequacy of design rests totally with the design. Additions, deletions or revisions to these drawing Ater Itis date will void this. acceptance and will require a itt=t4libTriiltal of ,revised dna =isms for edaroequei t AFRraval. tai i ?its Itertolitit taniinAp i neliy t' 1 t� �1" li 3f IGe Rita eat[tt7,'4 Buzau em.. - I ASIS ( Z SYM. NOTES QTY. TOTAL THIS SHEET 2085 108th Ave E Edgewood, WA 98372 (877) 209-5545 www.av-fire.com Lic # AVFIRSE952PM PROJECT: v I•N: �'tr:�iiiAlt.�R Opo TUKWILA FIRE DEPARTMEN1 Please call: 575.4407 and give this job No. Df6-'` It 1 and exact address for shut' down or restoration approval: SEA TAC Lic hti nc TI 4439 S 134th Pf' Tukwila, WA 98168 CONTRACT WITH: JV COP & SO\ 7612 113th ST E Puyallup, WA 98373 1 si 2008 Tukwila Fire ,.<s '3I/77 z 0 w z w CONTRACTOR: DESIGNER: AS DATE: As Noted SCALE: As Noted OCUPANCY: AHJ CITY OF TUKWILA JOB # SHEET # Site 7 z SD-FACP EXIST. RAMP SLOPES DN 15" TOTAL LANDING CONT. Ti / I-iANDRWIL SPRINK RM U WAREHOUSE OFFICE 0 15cd n 6 - SPRINKLER FLOW 7 - SPRINKLER FLOW 8 - SPRINKLER TAMPERS Storage Closet 15cd EXISTING WAREHOUSE NO WORK (45° max) 1 Hall t Wareh• se a Jim's Office OLCKT1 5 cd 5 TO FACP 15 cd Confere' Room Station TO FACP CKT 3 conf. table TO FACP CKT 2 EXIT r IQI LJ onference Room 75 cd Station 3 Recep. & Wa Station 4 Station 5 tation tation 7 AEIStatio 8 110cd Employee Lounge 115cd copier coder supplies L& cabinetry 11,5 n 15 Server Rooin Station 13 Station 9 LTJ 101 FIRE ALARM PLAN SCALE: 1/8" =1'-0" CLE z O z CONTRACTOR: DEVICE LEGEND DESCRIPTION SYM. NOTES QTY. DESCRIPTION SYM. NOTES QTY. DESCRIPTION SYM. NOTES QTY. 10" BELL B GENTEX GB -10/24 1 FAC P FACP SILENT KNIGHT 5820XL 1 SMOKE DETECTOR — PHOTO SILENT KNIGHT SD 505 APS 1 STROBE — WEATHER PROOF GENTEX WGES 1 HORN STROBE — CEILING MT ti GENTEX COMMANDER 4 4 HORN STROBE — WALL MT ti GENTEX COMMANDER 3 1 MONITOR MODULE SILENT KNIGHT SD 500 MIM 3 ANNUNCIATOR ANN SILENT KNIGHT — 5860 1 STROBE — WALL MT GENTEX COMMANDER 3 10 STROBE — CEILING MT GENTEX COMMANDER 4 1 PULL STATION P SILENT KNIGHT SD -500 4 TOTAL THIS SHEET 49 ire Security & Electric 2085 108th Ave E Edgewood, WA 98372 (877) 209-5545 www.av-fire.com Lic # AVFIRSE952PM PROJECT: SEA TAC Li htinc TI 4439 S 134th Pr Tukwila, WA 98168 CONTRACT WITH: JV COMP (Sc SO\ 7612 113th ST E Puyallup, WA 98373 DESIGNER: AS DATE: 4/8/08 SCALE: 1 /8"=1'-0" OCUPANCY: GROUP A AHJ CITY OF TUKWILA JOB # SHEET # FA -1 of 1