Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 7100 FORT DENT WAY - FORT DENT THREE OFFICE BLDG - PERMITS AND PLANS
7100 FORT DENT WAY ASSOCIATED PERMITS D19-0222 D18-0073 D18-0001 D17-0283 D16-0346 D16-0294 D05-275 D99-0190 D97-0395 M98-0228 19-F-192 18-F-099 18-F-005 17-F-211 17-F-012 17-F-006 14-F-023 13-F-289 10-F-100 08-F-300 05-F-215 99-F-235 99-F-234 99-F-212 99-F-203 99-F-178 99-F-069 19-S-211 18-S-104 18-S-029 17-S-236 17-S-019 16-S-238 14-S-031 08-S-259 05-S-208 05-S-176 05-S-028 04-S-240 02-S-222 99-S-232 99-S-211 99-S-204 99-S-180 99-S-149 99-S-091 SITE LOCATION Site Address: CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 710o Farr Tenant Name: tiaX — � C -L 4 o^ King Co. Assessor's Tax No.: Zq S "[ 1 0-0 Lf L/ D Suite Number: Floor: Property Owner's Name: New Tenant? ❑ - Yes ❑ - No Mailing Address: L0 �' (� C-V�'� ( c- &' yvv-c fir^ 4,e tvA 16-e <it 6 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Company Name: Day Telephone: Mailing Address: lbs— Y\-- �L 15 �� _ SL S im SSL LAp., qS*-261. 0 E-mail Address: --(\l ,�J k-C-FaxNumber: 266 `1.`te ���^� 1 _ Contractor's City of Tukwila NICET III number: Business License number: Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 2-\H v 0 L oCA �-- Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN/�UTH� AGENT: Signature: Date: 1 —Zg'e-t Print Name: \— .-4- ` I/V\A ^- Day Telephone: R D () S 1 t 3S v"\-- Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: '71 F'©i-+ Der -1 Suite Number: , Floor: Tenant Name: rn.—U C...- � � New Tenant? ❑ - Yes ❑ - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: .3P jt Ca_ j flfl Day Telephone: 4124 • q J - 7(pW/ Company Name: C Ytt in F1 re. 1 m c -\--i r)C- Mailing Address:' O )©x O'\rl\ cfeescv p\ &3 7 City �Z Cta�ste Zip, E-mail Address: � Ca eCart�WM� . (OM Fax Number: Ej- /- ��,� Total number of new/relocated devices or sprinkler heads: 1 I �p Valuation of Project (contractor's bid price): $2goO©-c0 Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING WNER OR AUTHORIZED AGENT: (C\ Signature: max . Print Name: rj),IthAwf) Je%IC`a `0)-)inSon Day Telephone: Date: , i /eK0 L/2 lig 17190 Plan Permit App.doc 1!2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** rj-� King Co. Assessor's Tax No.: Site Address: ---1/ 0 ^ ✓j f D en l wc1 [ Suite Number:c2O Floor: Tenant Name: AA\(\( -Ful P.M e 4/j New Tenant? g(- Yes ❑ - No Property Owner's Name: VO r L. UVI 1(.1� acid v {0n.e,e1 Mailing Address: c2v 3 5 5c A -- SFr= /VL r er is l,...V144 Lc"Ueitt' City State Zip CONTACT PERSON -if there are questions about the submittal. Name: ((.)SA‘,r\ 61,Ctinlaerri Day Telephone: a 253 -51-2 /'c7$ Company Name: 0 SL rl r; (- Mailing Address: 302 5— U k) r 4 S h Nei ivei Ave-- v v'J,d qg �-1 City State Zip E-mail Address:j u Si Y�c�J�C�ISGSP �.c�-r- L.►Y�°� Fax Number: (� LJ Contractor's City of Tukwila NICET III number: Business License number: g V `' '01'w/6283.2 Total number of new/relocated devices or sprinkler heads: v Valuation of Project (contractor's bid price): $ 5, o U 0 Scope of Work (please provide detailed information): 1(1 bbA\ i1 Gw et/ C c e 5 (p - Cr -Fug . PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature. 6 '"'y' Date: / — 4'70 (-7 Print Name: du) ffit 66%f'7 / Day Telephone: 0253 -07,2 '-1 qC? ( 8/22/14 TFD FP Form 8 Plan Permit App.doc 443"44 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** PAID FEB 24 2014 TUKWILA FIRE King Co. Assessor's Tax No.: Suite Number: Floor: 21\6\ New Tenant? M- Yes ❑ - No Site Address: ,C0 \OC T .\/\.\- Tenant Name: `mak I j v\ ¶ C C Property Owner's Name: Mailing Address: CONTACT PERSON -if there are questions about the submittal. Name:Day Telephone: i-`2A'1-4%I'7Coloci Company Name: QYI�`rP, ����-P Cfi\lNY-.) Mailing Address: V() X v' l \1 C't✓P 1 ` ` 2 — f City State Zip \_ E-mail Address: C� ��',[j.�.�' ���:1nTP. (t YY I Fax Number: �Z�' S\'' Total number of new/relocated devices or sprinkler heads: C Valuation of Project (contractor's bid price): $ 4iSM. cC } Scope of Work (please provide detailed information): ` L1 � � 1 �Q rte` City State Zip PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER QR AUTHORIZED AGENT: } j �%a%u GC. . il2i-fie 1..) Date: 2- i kP 1 V Signature: 0--)1 Print Name: �) €,\Cry. rfl s Day Telephone: 142.53. 4 eiM 1 1.01.p 9 Plan Permit App.doc 1/2/13 TFD FP Form 8 SITE LOCATION Site Address: CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 7 �O� FOS' 1 ft T W Pt King Co. Assessor's Tax No.: Z YW'Cb4 (jZ Suite Number: 6&C) Floor: 1. Tenant Name: Vv' raG R, ,-"' ) New Tenant? ❑ - Yes ❑ - No Property Owner's Name: btue....6/l Mailing Address: i3 kr-O , (AA a &"o 4/4 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: I--"*---- ���►` ((�� ��,, (� � Day Telephone: Company Name: �- l i �'!Elt��' �� rte_ -(4�2-VcCIZ°"1 Mailing Address: 10 `1-1`L 2-13 �j✓�'o,/`�� j\ VvA q$1 -c\ -Z) 11 __ (� City E-mail Address:.Q State i —Cr -5 i• ' t_i'L� ` M�~ �-Coi"Z Fax Fax Number: �� �� l (-1 ( f ^y��,� Contractor's City of Tukwila [ NICET III number: 151�'v"c)6oi, \ Business License number: Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ \ 3e5Z> Scope of Work (please provide detailed information): 1%1)0 k.\7)6Tf__ PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AU HORIZED AGENT: Signature: ii ij� Date: I J 2— Print Name: Plan Permit App.doc i6n Day Telephone: 8/22/14 TFD FP Form 8 44$SW447 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 7100 Fort Dent Way Tenant Name: Keurig Green Mountain Property Owner's Name: King Co. Assessor's Tax No.: Suite Number: New Tenant? ® - Yes ❑ - No Mailing Address: City CONTACT PERSON -if there are questions about the submittal. Name: Matt Carlman State Zip Day Telephone: 253-951-6005 Company Name: Fire Systems West, Inc. Mailing Address: 206 Frontage Rd N, Suite -C, Pacific, WA 98047 City State Zip E-mail Address: mattc firesystemswest.com Fax Number: Contractor's City of Tukwila NICET III number: Bryan Hilflker 99709 Business License number: bus -0994434 Total number of new/relocated devices or sprinkler heads: 15 Valuation of Project (contractor's bid price): $ 2500 Scope of Work (please provide detailed information): Install new fire alarm notification devices for tenant improvement. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTHORIZED AGENT: Signature: [/ I_ Date: 01/24/2017 Print Name: MattCarlman Day Telephone: 253-951-6005 Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No/..:2—°V)VC1(31-0-1(40 Site Address: o V hD(T nrr vV t Vkl,,lr\ Suite Number: /5 Floor: Tenant Name: .eu123g 1 't.3A- leN rv1.O(il,N1-°` New Tenant?, Yes ❑ - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: rixOcv'tc— r‘ Name: 1 P r<SC-- Mailing Address: 1'2_ ti-- 215 (\� Com* '" ' o �(J � ZLk t ipi E-mail Address: -t c iS� � Fax Number: NICET III number: a) 'W -1 Total number of new/relocated devices or sprinkler heads: L Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Day Telephone: LO6 3) 1 ZC7 Contractor's City of Tukwila Business License number: 1\ZZ 4, 1 -do cteNTc-- Orr k PERMIT APPLICATION NOS' Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: Print Name: Plan Permit App.doc 8/22/14 Day Telephone: Date�� TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 295490-0440 Site Address: 7100 Fort Dent Way Suite Number: Floor: 1 Tenant Name: Keurig New Tenant? ❑X Yes ❑ - No Property Owner's Name: John C Radovich Dev Co . Mailing Address: 2835 82nd Ave SE #S-1 Mercer Island, WA 98040 CONTACT PERSON -if there are questions about the submittal. Name: Matt Carlman City State Zip Day Telephone: 253-951-6005 Company Name: Fire Systems West, Inc. Mailing Address: 206 Frontage Rd N, Suite -C, Pacific, WA 98047 City State Zip E-mail Address: mattc@f iresystemswest . com Fax Number: Contractor's City of Tukwila NICET 111 number: Business License number: BUS 0994434 Total number of new/relocated devices or sprinkler heads: 2 Valuation of Project (contractor's bid price): $ 1,500.00 Scope of Work (please provide detailed information): Relocate 2 existing fire alarm notification device for tenant improvement. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time. for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER I R dTHORIZED AGENT: Signature: Date: 12/26/2017 Print Name: Matt Carlman Day Telephone: 253-951-6005 Plan l'ennit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. 71612 Site Address: -799-Fort Dent Way **PLEASE PRINT** King Co. Assessor's Tax No.: 2954900425 Suite Number: Floor: New Tenant? R] - Yes ❑ - No Tenant Name: Fuse Networks Property Owner's Name: John C Radovich Dev Co Mailing Address: 6840 Fort Dent Way, Tukwila, WA 98168 CONTACT PERSON -if there are questions about the submittal. Name: Matt Carlman Company Name: Fire Systems West Mailing Address: 206 Frontage Rd N. Suite C E-mail Address: MattC@firesystemswest.com City State Zip Day Telephone: 253-951-6005 NICET III number: 146053 Pacific City Fax Number: Contractor's City of Tukwila Business License number: WA, 98047 State Zip 253-735-0113 BUS -0994434 Total number of new/relocated devices or sprinkler heads: 5 Valuation of Project (contractor's bid price): $ $4,000 Scope of Work (please provide detailed information): add 5 new fire alarm notification devices PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 5/1/18 Print Name: Alex Kawalec Day Telephone: 253-833-1248 Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** //��, King Co. Assessor's Tax No.: /� Site Address: 1 r bp 1ii h l �� Suite Number: I ``/ D zA iiq0-04 �1a Tenant Name: ON i2 -..P.010-3 L Property Owner's Name: \©L\ C Mailing Address: 7_61 CONTACT PERSON -if there are questions about the submittal. Name: LA/`` t'L o c Company Name: C - r' Mailing Address: E-mail Address: Floor: New Tenant? Qf - Yes ❑ - No Y'"C.11_.et- 15\L-. City State Zip Day Telephone: 2_06 �C7L�'L U� f\ S , Sl. L j/51 �bZ 5 -6 �(� e_T&\& I -41Fax Number: 36 6 l S retk C1 i Contractor's City of Tukwila Business License number: NICET III number: -C Total Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): P p D S X10 CArt(... L b Co () ci• f ` `CALL Q.z< : STi \ ` C-xv � CSara": t%� ¶ S PERMIT APPLICATION NOTES V Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE R AUTHO IZED AGENT: Signature: —� Date: Print Name: 0A11--S-1U n�f Day Telephone: � I 3415 -3 -- IF Plan Permit App.doc 8/22/14 TFD FP Form 8 44iitt"44 SITE LOCATION Site Address: Tenant Name: 1 A 0 J L 100 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 79oT YJT r&\ PATO P" 232319 TUKWILA FIRE King Co. Assessor's Tax No.R CINCH �D y(..(� Floor: ' Suite Number: )o 0 New Tenant. - Yes ❑ - No Property Owner's Name: O"\ C 4,1).( CT b...V Mailing Address: ZnS I �j ' SLC 1� w,Nct`c L( o City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Litt",, -t c. iY\-P-/\ Company Name: f t /--S---c ZL -c_ Ft('-- �` Mailing Address: fr - f 1— 21 ,/ \VL._ -c(_. r � City ; 1 , C oil, StatY Zip E-mail Address: c (-5�� L`tYN,S� c ('e- l�/tY' 1� Fax Number: 3 CO 4' ( 2-C6-00 ^O P '"C Contractor'sCity cense number: NICET III number:`� Business cense number: Day Telephone: ? CC 5-11 3c\S 3 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ b Scope of Work (please provide detailed information): 14 O PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE : : ' AUTHORIZED AGENT: Signature: - Date: &C IS- (I Print Name: r. f' ti Day Telephone: 2_06 S 1 I 3S5 -5 --- Plan SS5---Plan Permit App.doc /22/14 TFD FP Form 8 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION King Co. Assessor's Tax No. 2954900440 Site Address: 7100 Fort Dent Way Suite Number: 10 0 Floor: l S t Tenant Name: Tabor New Tenant? Yes ❑ - No Property Owner's Name: JCR Mailing Address: 2835 82nd Ave SE, S-1 Mercer Island WA 98040 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Matt Carlman Day Telephone: 253-951-6005 Company Name: Fire Systems West Mailing Address: 206 Frontage Rd N. Suite C Pacific WA, 98047 City State Zip E-mail Address: MattC@firesystemswest.com Fax N umber: 253-735-0113 NICET III number: 146053 Contractor's City of Tukwila BUS -0994434 Business License number: Total number of new/relocated devices or sprinkler heads: 9 Valuation of Project (contractor's bid price): $ 4500 Scope of Work (please provide detailed information): Improvement. Install New Fire Alarm Notification Devices for Tenant PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHa GTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AUTHORIZED AGENT: r C c �,� 219 Signature: Date: 09/23/2019 batt Carlman TUKWILA FIRE253-951-6005 Print Name:Day Telephone: Plan Permit App.doc 8/22/14 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Wood -Richardson 7100 Fort Dent Way #225 Permit No.: 17-S-236 Date: December 12, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Therapeutic Associates 7100 Fort Dent Way Suite 220 Permit No.: 16-S-238 Date: November 16, 2016 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 21h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructedlnon-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Washington Youth Soccer 7100 Fort Dent Way Suite 215 Permit No.: 14-S-031 Date: February 24, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 % inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 fl.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Keurig Green Mountain 7100 Fort Dent Way Suite 160 Permit No.: 18-S-029 Date: February 6, 2018 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. A FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Tabor 7100 Ft. Dent Way Suite 100 Permit No.: 19-S-211 Date: November 8, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' off the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath aN obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Weld stamps shall be inspected on the ground, before pipe is hung. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterilow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2019 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Fuse Network 7100 Fort Dent Way Suite # 140 Permit No.: 18-S-104 Date: May 24, 2018 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 21/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. I • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Keurig Green Mountain 7100 Fort Dent Way Suite 150 Permit No.: 17-S-019 Date: January 31, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. CORRECTION NOTICE/REINSPECTION FEE "� Inspector: T 4 `,S'3 Permit number: DI 9 -02-2- 2— TUKWILA FIRE MARSHAL'S OFFICE Office: 206-575-4407 Fax: 206-575-4439 Email: Fire Marshal@tukwilawa.gov Business Name:•1 3 Type of Inspection: r—�� Location Address/� 6 )14,1- P1/ Date : z �I ( i f 11 Contact P,erson : '>CL(/vC VAScAvr+ gT'tO(. Phone No. :\ Sc (206) 96z - 0U $J ACTION REQUIRED : 1 Sr 2.4° loom___ 4//4-70 /V /-/e ,moi f -A- s. ai syp�. N FrP\ 72 CORRECTION OF . , ABOVE ITEMS ARE REQUIRED BY : J I�+J ( 2-©2 FAILURE T Signature: Billin ' ming Address : ,r/Y RESULT IN THE ISSUANCE OF A CRIMINAL CITATION/TICKET. Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Reinsp Fee2.doc Revised 6/17/14 T.F.D. Foran F.P. 100 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 9-QZZZ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Projects-- /�,�� Type of Inspection: Nr.& ,iii-- ��4--i Address:___,Contact Suite #: lOb -1----bar ba....41— k (itI ItcYPhone Person: Special Instructions: No.: Approved per applicable codes. COMMENTS: Corrections required prior to approval. /1-1444r‘ /A/Creo-%-1 ‘,01eAgife-, ////112-"" /11/ 01''ts-e-e--74?/1-1 65-77,44, I fits_c 01J Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:ZL_Date: /21////1 Hrs.: 4.6 _ , / n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ,47-f- I7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: /60r f Sprinklers: Type of Inspection: Address:Contact Suite #: 7/ij o/t-i , M Person: 6/41d Special Instructions: A Permits: d fl Phone No.: e(TZ-0a(5--f Approved per applicable codes. COMME • nCorrections required prior to approval. epp&OL Needs Shift Inspection: f Sprinklers: Fire Alarm: Hrs.: Hood & Duct: Monitor: Pre -Fire: Permits: d fl Occupancy Type: Inspector: '1 (Nl f ..4,k L Date: 4 -74,11C1 Hrs.: 1< < $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 2 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1J19 - z22, ,/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: (4t77 /i6frVs l NS T- r�-Z4fQd Type of nspection: / •luxur Address:Cona Suite #: 7/ 0 0 4.---i- ���, "'0- e rson: t� Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval.` COMMENTS: (4t77 /i6frVs l NS T- r�-Z4fQd Monitor: Pre -Fire: Permits: Occupancy Type: 11( 0})- /67 — 41/ Ai0114e1 /#41ZCIAte— 21,--e./ �, ate,., t _ -, �, IL� _• Al . . Led Ea_ 1–,Y • _. •, al, . 4.. I' - 2 I W Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: c. Date: ///7-7/ i Hrs.: $100.00 REINSPECTION FEE REQUIRED. 1You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 n. w • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit �I9-Q1-22 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:— 7—b a r-- Sprinklers: Fire Alarm: Hood & Duct: Type of Inspection: 0//,QA 5/p Address:erso Suite #: 7) -_1 1�1' 0„�" 0 a Cont ct Person: Special Instructions: Phone No.: 0/ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: — /01/6MVE Occupancy Type: , S r-1 1.4ak r fliws dam+ s')- )ra/ 0/ %a caueA ` fry f ( ,A /. v 740104-7 e770'11 j G w �1 4/20.-174--%L Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: , ` Inspector: ,it_ Alf 63 Date: 11//2//7 Hrs.: .. 6 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 e Z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit T)teb — d?13 12 -F —O?9 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:���� l U�,kiJur (4 Date: d ih S Type of Inspection: P5v'X. A/A-rtivt Address:10 Suite #: /100 .r+ �,-� Contact Person: Special Instructions: /-4,4„1„, n �I- Phone No.: Approved per applicable codes. I I Corrections required prior to approval. COMMENTS: Ad0fgal A —OQV1C 14/5 54n11.c Dtil1 Needs Shift Inspection: h/fri 53 Date: d ih S Sprinklers: \{.t4 Fire Alarm�r,aS Hood & Duct: Monitor: /-4,4„1„, n �I- Pre -Fire: Permits: Occupancy Type: 2? 1 Inspector:' . h/fri 53 Date: d ih S Hrs.: /. Q $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:S� i vv16 4 Type of Inspection: 5 (NGat- Address:Contact Suite #: 77 u Mgr Asill-- k e y Person: Special Instructions: pi 40 ( Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6 7730 C_/e-r2- etilINfr/%rl, F Net- 1'�L Needs Shift Inspection: Sprinklers: ye 5 Fire Alarm: .e.,S Hood & Duct: Monitor: /�yyi c �- l Pre -Fire: Permits: Occupancy Type: R Inspector: fin c Date: g%fj $ Hrs.: n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Di -KV/ ie -s- O 2cj' PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ZeZ(g/6 Type of Insion: /74- — Ca vo., — /./,<1-(' Address: � Suite #: ?/UO Orf 00_�� /CV Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ifmc_ i/) /ivpE-y i Perla, Fire Alarm: yiS Hood & Duct: Monitor: Pre -Fire: Permits: //// -7521,47e Con6jo-b-IS Alw � , PCs D (c 77> .er - b',:z AfAZ-til -- ,42d Z ctGo 4 e / al - & c` - r..e niv09-/ _..e D 4 ,1 0(10:€ y fits_ AdaPi, /4.t e1` /V (2) .31‘-0“/ Needs Shift Inspection: N 0 Sprinklers: p..1 Fire Alarm: yiS Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: , Inspector: 7...._ /,‘f5-3 Date: 3/0 8 Hrs.: KA.I/ A, . 1 / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 l INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: �Ent(4 f g J Type of Inspection: ( -a--- Address: Suite #: WO 6 1. pLal"11—"70 Contact Person: (.449--n4 , Special Instructions: Permits: Phone No.: I I Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: ' ( ' Fire Alarm: Hood & Duct: Monitor: cP 2) CiAl7N167eN(2-ceg- q r�,evs Permits: -Tv6---/- ,9,J -- e6 ----"i7 Tz or---- openi S ,?-0 Q EI.1 0 op- L/�..rE Gt i.. i r -az- i opr -`- z d 77 (-ever-- AM r /9"fr--z7 x13 Needs Shift Inspection: te-e,j Sprinklers: ' ( ' Fire Alarm: Hood & Duct: Monitor: ! Pre -Fire: 7 Permits: Occupancy Type: Inspector: S--4--- Date: 242,4 K Hrs.: f $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit O2€3 11 —5 — PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: OoD R.k.c..L tuvr-Zi,,, Type of I spection: Co—J-4-x Address: -Th Suite #: � ( CZ ��- �1- Contact Person: Special Instructions: y.e.S Phone No.: Approved per applicable codes. nCorrections required prior to approval. COMMENTS: X. covw- Sp -- o \C-_ -Ft-ok I • mss Needs Shift Inspection: /ulA. Sprinklers: y ....liiS Hrs.: Fire Alarm: y.e.S Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Z Inspector: __ , - 3 Date: /z// y b) Hrs.: / .0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit by -Oa Ei 17-F- Wit( PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: //AA // r _ 2Dbet. C tv/iir Type of Inspection: Address:....„ Suite #: //0 fr",e,,,Itifr , ZZS Contact Person: Special Instructions: Monitor: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /-1/2`7L- AvSr 72q uael/el y Needs Shift Inspection: tv/iir Sprinklers: }/.Q'J Fire Alarm: Y p Hood & Duct: Monitor: -,-v,,. a- Pre -Fire: Permits: Occupancy Type: Z Inspector: ; cyki,f7 Date: / u/y/l ) Hrs.: p $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 V INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Icoieic,7 Type�n,,/s�p�ect� Address: /^ �-- Suite #: ��� f'`r ��� Conta Pers Phone No.: Special Instructions: Atco Approved per applicable codes. nCorrections required prior to approval. COMMENTS: F/4- -F t-1 479ea-dv Acti. firprz-ovt-- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 17)4 c Date: 2J124-/(7— Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit p11, -a -3w PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:�� f� Type of Inspection:' f1'<<j�l�tn//Ki /.44 -1 --- ntact Person. Address: Suite #: t00 4g" beir Special Instructions. "it, Phone No.: RIFproved per applicable codes. riCorrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: r/4 /(%6riit of4Nte--0 x77241 "s /,./ see -Z.6-- r r✓o T 3yni c 0 ("V 5 6E`S /n/ frl'/ft — . Occupancy Type: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: f--ivi s-4_ Date: 3/24117..._ Hrs.: • n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 fI� INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit j>110-634,4, PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 1Type ic (� �f t / & of Inspection: /f ov ic- ce-Ni,e__, Address:Contact PersonJ• ne:40 n frw7—_ Suite #: � &rot? j Special Instructions: 45D Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: S epiA bysn 144 R -O r 6 ec - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: F.744, 5-4-- Date: / A z Hrs.:' $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 V' INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: g710(1467 Type of�I,nr�s�pe ion:C�E� Sii"_ ` Address: Suite #: � Fvr00r t Contact Person: L4;iI 4P/7 --- Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: -4-1)0f) +-7\ifl 0,P z_tosv&-- Pcsiy2-47/\“-s 77-0-0/621-zirv-r- 1 - I__-, 4,(2,-, 0,12_ (2,---,Ty2A-7,-r- iug-----Am Asevr-- 1/4,4) Lin /N L—r•fria-11 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: r.744 S-4. Date: 224-ljq.-- Hrsi(: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 4F7/1._t�7 Sprinklers: Type of Inspection: Contact Person: "iAIZ.i 1'►ti Address: Suite #: 6-6F T t�M Phone No.: Special Instructions:20 Approved per applicable codes. Corrections required prior to approval. COMMENTS: --- 50 .v'1 - iru:fl - irk — E714 c—irz-Gz6r lc A (-( tA/15? — 61 -c -- Needs Shift Inspection: Sprinklers: Fire Alarm: ' Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: frill c• Date: (2/h 4'// Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 17-F- 00 (� DK, — 02`f Y PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: A4/fr / /- Fire Alarm: Type of Inspection: �/-� Address: Suite #: 7100 j/4---1 ii ,.- if Contact Person: Special Instructions: Phone No.: p( Approved per applicable codes. Corrections required prior to approval. COMMENTS: Aid / 5.9x4 &e- — 14(g Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspect -6: Z4 I-3 -3 Date: 2/121/ 1 Hrs.: 1 .. 0 j $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit JG -3-2313 1.16 -02`� PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: le/t/. it/ Sprinklers: y Type of Inspection: �� vW— Address:b Suite #: 7/c0 j rt-�, jo Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 04 � Coy.. r'` Gv/ TI,.c- ew)-sek4� 1?,41— /'t»-/ 3r09 -a- a�! f� or' /,,mss �.1/ �e 7.yeg744, 1-60 Coo& gp/% //gA--1 I — 7 . ,s4 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 929 3 Inspectdj ,Z(3 Date: i/ j'�J 7 Hrs.: %_ d $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 TUKWILA FIRE MARSHAL'S OFFICE Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshal@tukwilawa.gov 4 AV CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date /1/1211-9- Permit# Property Address 1` �•, ` � �; Suite # CZ-5— Cit. Z5— City TUKWILA Zip Code Name of Facility Occupied as Owner or Representative Installing Company VW..., 5 Installing Contractor's Address Z,CO qc C_- PO C.I' T WA -- Phone # 2553 331 &L ( Phone # City poi u ?, Installer's Name (PRINT) .AOUTY\ ► k \he, License and/or Certificate M[ L -NE Ru 3T General Contractor DU - Electrical Contractor FACP Equipment Manufacturer Ra01IOYUGs Model # qb7.„ This s}stem has been installed. pre-te. ted d and operates in accordance with the standards listed below and was inspected by J�0 VV\ l -Q� On (date ) Ltd,zI11- and includes the deices listed on hack. Circle all that apply: 0 NFPA 72, Chapter 1 2 4 5 6 7 and/or IFC SEC 907 n (/ NFPA 70, National Electrical Code, article 760 Manufacturer's Instructions Manufacturer's Instructions (" ther (specify ) ukwila Cit% Ordinance Numbers 2050. 2051 UL Central Station Monitor System is monitored by flOkINGV 5.. p s SIGNED Date t S., stern Firmware: Installed %ersion Checksum Date Initial program Installation Date Re%isions and Reasons Programmed by EQUIPMENT INSTALLED AND TESTED: Control Panel _ of _ Make/Model Manual Station _ of _ Make/Model Smoke Detectors _ of _ Make/Model Heat Detectors _ of _ Make/Model Duct Detectors of Make/Model A/V Devices 1( of Make/Model (Aikido c./ fSC e.... - Audio Audio Devices _'of _ Make/Model , • Visual Devices _ of _ Make/Model Auto Door Release _ of _ Make/Model Trouble Indictors _ of _ Make/Model Batteries Readings Battery Full Load Charge Generator of _ '. ' 112Iake/1VIode1 HVAC Controls of - • Mak"t/Model Fire Alarm Dialer _ of _ Make/Model Monitored by _ . • . , d. • Annunciator _ of _ Make/Model . •. ' r Sprinkler System. (Fire Alarm connections only) Water Flow Sw. _ of _ Make/Model Valve Tamper Sw. _ of _ Make/Model PIV _ of _ Make/Model t Elec. Alarm Bell of Make/Model Automatic time Delay of Water Flow Alarm seconds. None Installed Do you meet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes No Test of alarm System on emergency power, satisfactory? Yes _ No Test Witnessed by Title Date • Comments • Fire Alarm Certilicate.doc ReN,i sed: 6/17/14 TED FP Form #1 10 TUKWILA FIRE MARSHAL'S OFFICE Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshalCtukwilawa.gov 4,44*A"ZtvCONTRACTORS NLATERI.AL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Wats Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date 3– Permit # 1'7— F"O/ Z Property Address /6O T ✓j4 ��'' o/ Suite # Cit. TUKWILA lip Code CNIgo Name of Facility 1 OZ ► e.)114 - 1 r. Occupied as Keu>n ev-r ee.r /46vx–ituis p 61t14 SIO) 1Y\i� Owner or k� rzentati�e /�" � �,,�Phone # �y / 3 Installing Company ''Iz Sy$�a -. Coe -a -f— Installing Contractor's Address 20 (i• I....Y:i/4-600-V £S Lt Citi i'u//yy d e j.G Phone # 2C3 t 3 3 n_scs Installer's Name (PRINT) J41*_rari /C4%/it. License and/or Certificate A/L.)' E, APTS/5r– General 7 75General Contractor /1« S►litd"G41.--i Gt./ea- I--Electrical Contractor /1-4) FACP Equipment Manufacturer /S'ut /SO4,117C Niodel # r ?97Z ------ -re 777/.r This system has been installed. pre -tested and operate; in accordance with the standards Iistedbelow and was inspected On (date) 2—Z3--/7– and includes the deices listed on hack. Circle all that apply: NI -13A 72. Chapter 1 2 4 5 6 7 and/or IFC SEC 907 8NFPA 70. National Electrical Code. Article 760 Manufacturer's Instruction: Manufacturer's Instruction; Other K;pecif} Tukwila Cit.. Ordinance Number, 2050. 2051 UL Central Station Monitor ( 151 s., stem i; monitored h` , 1i ik can f 1 he., S [GNED e Date System Firmware: Installed version Checksum Date Initial program J, Installation 'Pre,Stidier6 (, t Re‘i;ion, and Reason. Date Programmed h. EQUIPMENT INSTALLED AND TESTED: Control Panel Manual Station Smoke Detectors Heat Detectors Duct Detectors of of of of of A/V Devices O of Audio Devices of Visual Devices of Auto Door Release of Trouble Indictors of Batteries Readings Battery Generator of HVAC Controls of Fire Alarm Dialer of Monitored by Make/Model Nlake/Model Make/Model Make/Model Make/Model Make/Model ti/%LtthLe---- Make/Model Make/Model N[ake/Model Make/Model Full Load Charge Make/Model Make/Model Make/Model Annunciator of N[ake/Model Sprinkler System. (Fire Alarm connections only) Nater Flow Sys . Valle Tamper Sm.. PIV Elec. Alarm Bell of of of of Make/Model Make/Model Make/Model Make/Model Automatic time Delay of Water Floe Alarm seconds. None Installed [)o `ou meet audthle/risible requirements of HVAC 51-20, IFC SEC 907., and/or NEPA 72 Chapter 67 No fest of alarm Sy stem on emergency poser, satisfactory? Test V [messed b‘ W1/4 Title Comments: No ? C� . p."- ,CCLJ)ate 3 11"- \ I arm 1"- \farm Certificate dna ised Fi/17 I.1 TFD FP Form #I lu c 1 TUKWILA FIRE MARSHAL'S OFFICE Phone: 206-575-4407 • Email: FireMarshal a tukwilawa.goy CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date Co/,/ /41 Property Address 7/9,10 City TUKWILA Permit /'‘ -..46cfl ;Z -T- -De wf y Name of Facility fo9..7 '3 1:-,v j Occupied as Suite# IYch Zip Code 9 `6I Co 41) tie.7 L.) e-12-1 Owner or Representative Phone r Installing Compamv / iRF' SYS ,c„r C./ CS r Installing_ Contractor's Address (... f Ao'�s?�ifj� 2� /v'/ fuirN-C City 7/4crs2ic Phone 2-M ?. 3 — -VS--> 4'Y Installer's Name (PRINT) fN(Ak2c,,.) rhie vcr License and/or Certificate M u Wim' t c Ll Ci General Contractor Electrical Contractor 1712[= Sy3r&rts L -Xe r I S;" Cw►S W( -"ST FACP Equipment Manufacturer 17_,>,b cm,Ac S Model This s), stem has been installed, pre -tested and operates in accordance with the standards listed below and was inspected b\ M - CAluw..,h.) Q. Ir./tee- rjsr -Afs 41-6-s '— On (date) (p/c//and includes the devices listed on back. Circle all that apply: NEPA 72, Chapter 1 2 4 5 6 7 and'or IFC SEC 907 NEPA 70, National Electrical Code. Article 760 Manufacturer's Instructions Manufacturer's Instructions Other (specify) Tuk'.ila Cit. Ordinance Numbers 2050. 2051 LI_ Central Station N1 itor Sstem is monitored b‘ SIGNED Sstem F irmw, ark: Installed version Initial program Installation Checksum Date L/G//5r Re\ inions and Reasons Date Date Programmed b‘ EQUIPMENT INSTALLED AND TESTED: Control Panel of Make/Model Manual Station of Make/Model Smoke Detectors of Make/Model Heat Detectors of Make/Model Duct Detectors of Make/Model ATV Devices 3 of 3 Audio Devices _ of Visual Devices of _ Auto Door Release of Trouble Indictors of Batteries Make/Model Lahee_toc"... Make/Model Make/Model Make/Model Make/Model Readings Battery Full Load xcc-c.4%. Generator Generator of Make/Model HVAC Controls of Make/Model Fire Alarm Dialer of Make/Model Monitored by Annunciator Charge of Make/Model _. Sprinkler System. (Fire Alarm connections only) Water Flow Sw. of Make/Model Valve Tamper Sw. of Make/Model PIV of Make/Model Elec. Alarm Bell of Make/Model Automatic time Delay of Water Flow Alarm seconds. None Installed Do you meet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes No Test of alarm System on emergency power, satisfactory? Yes No Test Witnessed by Title Comments: Date Fire Alarm Certificate.doc Revised: 6'1714 TFD FP Form #1 10 La(' '' ii U�Cw i�a t' i Fcs 5-1S �p,S. L (o sO CONTRACTOR'S MATERIAL AND TEST CERTIFICATE FIRE NJARM AND FIRE DETECTOR SYSTEMS 2 '214 1.-71,../.4140"' PROCEDURET-FIECTOR DATE lk/2, Pf Upon completion of work, inspection and test shall be made by the contractor's representative and witnessed by local fire department. All defects shall be corrected and system left in service before contractor's men finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for inspecting authorities, owner and contractor. It is understood the owner's or representative's signature in no way prejudices any claim against contradtor for faulty material, poor workmanship or failure to comply with inspecting authority's requirements or local ordinances. Name of Facility Cork 424 MC Property Address 7?tots rort itiaNf L.141. iv‘lpti-l4. i, Occupied as / Zip Code Installer's Firm Name g Q k,J.(le co,L0,1147 Address of Installer PO ac„c '1cDt4 04,1 S 8 Electrical Contractor's License Number f i ATC% 71- 044 QF Wireman's Certification Number` URri4y-1y 4L1' Tests witnessed by 44 Seel -4 Title 4 Date LVIS141 to certify that this fire alarm system has been erviced (circle one) in accordance with the standards e• by the local authority' having jurisdiction and is consistent with NFPA Fire Alarm Standards. A. Name of Firm SNIAlet.1j4e„ faON ry Phone y sFr S- (t`clo B. Mailing Ad • ess AD Aoy, 2 i1 / C. Name (Signature of Firm Official) Qe c> 4 . ca6S2 it -14444 Title ,ck Date //q95 Additional explanations and comments 20 2 41.4SI) AQUIPMENT INSTALLED AND T.. .ED TYPE OF EQUIPMENT NUMBER OF UNITS TEST,BH TESTED OAT" r SATISFACTORY CHECK MODEL AND MANUFACTURER Yes No N/A Panel t ....«Control y/I cher ✓ 4,14-i & Manual Station 11 Heat Detectors Smoke Detectors 41; II/chi) Audible Alarm Devices 21 Visual'' Alarm Devices _A Code Transmitters Automatic Door Releases Trouble Indicators ohI�, Master Alarm Box Batteries 11/191 Charger 2 liter ” Generator Ventilation Control 4 1. '1 SN Fire Department Interconnection Central Station 1/1/6/151 t/Interconnection Exterior Sprinkler Electric Alarm Bell i 'IV Siti Sprinkler Water Switch / /5� pit `/Flow Sprinkler Gate Valve Supervision Switch 2 �/ 1/%5 i% Annunciators I Y/S-rn Automatic Time Delay of General Alarm# Minutes. None Installed 0 Test of alarm system on emergency power, satisfactory Yes B' No 0 Local Fire Department Acceptable Yes I/No ❑ Comments: City of Tukwila Fire Department OCT 9nrIc TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name � �? r� Address , ..> -) F 49e Permit No. Retain current inspection schedule Needs shift inspection Suite # %(- Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Occupancy Type: Authorized Sigrikure Date Final Approval Frm Rev. 5/2/03 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 City of Tukwil Fire Department JULF] 3 0 1999 John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name /(7(thipt•Cdc7 i 14- Te -S Address /v u r()leT Thomas P. Keefe, Fire Chief Permit No. -'v/ C% L� Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: A -o ?r r / 1/ !a t_,4 (/ 1 L7,2 Authorized Signature FINALAPP.FRM 7,/32/2 Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Project Name TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM GCS APR 2 3 1994 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No.1B-�ac:;.s. Address -% (O D C"� Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Ac TV' Pre -Fire: Permits: 4\ ‘5 Authorized Signature Date FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department APR 1 5 1999 John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name 1FDck TV Thomas P. Keefe, Fire Chief Permit No. Address ---1‘00 � D* DST Retain current inspection schedule Needs shift inspection Sm kc 7,3-00t Suite # � Approved without correction notice )(\ Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: A1acw. Utrker 5/ Authorized Signature FINALAPP.FRM Rev. 2/19/98 4\15\ Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 si )4\ckoi TUKWILA FIRE DEPARTMENT A ,3 Co FIRE PREVENTION BUREAU ColvIAR, (206) 575-4407 CORRECTION NOTICE/REINSPECTION FEE 4AlEkn BUSINESS NAME: D VN(c\c' .. DATE: ADDRESS: -1 l r3U A. O `jBLDG: SUITE: N APT- TYPE OF INSPECTION:{nW L INSPECTOR: 5 to BLDG. PERMIT #:kflajebiC CONTACT PERSON: PHONE: ACTION REQUIRED:1 ` ` Q.-�_•Y'l Pi 1.j_ Tr-� 5 !\✓1ri)til !� c\ L� V ek\\C fS.51ky.4..t. - CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY: 41A Z°1�'� A Reinspection Fee is required and must be received by the $40.00 Tukwila Fire Department, 444 Andover Park East, Tukwila, Wa. 98188 prior to reinspection. Make checks payable to the City of Tukwila and provide the YELLOW copy of this notice with payment. FAILURE TO PAY the reinspection fee within seven 7 days may result in the issuance of a citation for Failure to Comply. For Office Use Only: Date Paid: Receipt #: File Code: W -Finance Y -File P -Contractor WP:CORREFEE.FRM T.F.D. Form F.P. 100 FIRE PROTECTION, INC. PO SOX 12642 MILL CREEK WA 98012 (4251 290-9600 OR 1-100-681-1125 FAX (4251 353-4546 May 19, 2010 City of Tukwila -PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed plans for FIRE ALARM SYSTEM. The system has been designed per NFPA 72, 2002 edition requirements as well as WAC, IBC, IFC 2006, NEC current and your additional requirements. Fire Protection, Inc. will add/relocate devices per plan to the existing system. The building is fully -sprinkled. The system shall monitor by zone activation as well as separate trouble signals. Monitoring shall be provided via UL listed Central Station, The Alarm Center LACEY, WA., over 2 analog lines via a built in DACT. Audibility shall be in compliance with NFPA standards with a 10 inch bell located on the outside of the building in the top 25% with a 117 candela strobe facing the first in -coming FIRE DEPARTMENT vehicles for easy building location. Interior DB shall be 75 DB minimum throughout. A full service and monitoring agreement is in force for the proper service and maintenance per NFPA requirements. All systems shall be UL certificated and placard. A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. 1730 Gibson Rd. Everett, WA 98204 WSCL# FIREPI*021ML UL CERT #608242-002 JOB SITE ADDRESS State Farm 7/0440* Fort Dent Way 24P��— -2l,o Tukwila, WA. APPROVED UL MONITORING COMPANY Alarm Center, Inc./FPI 4300 3rd Ave. SE Lacey, WA 800-429-0991 UL CERT #902799-02 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring; Service; Testing; Runner Serv; Fire Protection, Inc. UL Cert; Fire Protection, Inc. ADIENT TEMPERATURE S No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AMBIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per DBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify UL listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re -dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, (no notification circuits shall activate.) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds. Low air shall activate at 251bs, causing for a supervisory signal. A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause alarm. Shorts on PIV, tamper and Hi -low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal. Should you have any further questions, please feel free to contact me directly. Roy L. Cats Project Manager CFPS #1473**NICET-4 #09786**SFD #SCP -9955 CITY OF REDMOND DESIGNER OF RECORD #B-0-002 SILENT 5495 Pc,..er Expander Ca'cu!a;:ons Version 02 lig Panel ID: 15495 Location: 'Fire Alarm Control Room — Global Project Values: Project Name: Project ID: Prepared By: Date: State Farm 'Roy L. Cats 5/19/2010 Standby Hours: Alarm Mins: Derating Factor. Voltage Drop Waming Threshold % . Model: 5495 Power Expander ' Volts: 24 VDC 60 5 1 1.2 10 Max NAC Current 3.0 Amps Max Panel Current 6.0 Amps Ckt.# Circuit Name __5495__ _,_ j 5495 Pwr Module Current Draw Wire AWG Ohms Per Length(ft) Actual Volts © Standby Alam' & Type 1000 Ft. One -Way Ohms EOL 1 1 0.0751 0.205 1 NAC #1• • NAC #1 0.000 0.652 #16 Solid 4.02 250 2.01 19.09 NAC #2 Not Used 0.000 0.000 #16 Solid 4.02. 0.00 20.40 NAC #3 Not Used 0.000 0.000 #16 Solid .. 4.02 .0:00 20:40 NAC #4 Not Used 0.000 0.000 #16 Solid . 4.02 0.00 20.40 Aux 5495 Aux Power Out 0.000 0.000 #16 Solid 4.02 0.00 20.40 Total Standby Cunent (Amps). 0.075 0.857 Total Alarm Cunard (Amps) Alarm Time In Minutes / 60 (5 Mins) Total Alarm AH Required Standby Time In Hours TotalStandby AH Required Total Combined AH Required 60 0.083 4.500 0.071 4.57 Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 5.49 12VDC 7Ah Batteries to be used Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Configure Circuits CPrint Page Circuit Configuration Project Information Project Name: State Farm Prepared By: Roy L. Cats Project ID: 0 Date: 5/19/2010 Ckt. Number. NAC #1 Panel ID: 5495 Ckt Name: NAC #1 Max Circuit Current 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.464 2 System Sensor S/SC Strobe (30cd) 0.000- 0.094 0.000 0.188 Unused 0.000 0.000 ' 0.000 0.000. Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.652 Ckt. Number NAC #2 Pane l ID: 5495 Ckt. Name: Not Used Max Circuit Current 3 Amps QtY Device Current Draw Each Current Draw Total Standby Alarm Standby Maim Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 ' 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0:000 Totals 0.000 0.000 Ckt. Number. NAC #3 Panel' ID: 5495 Ckt. Name: Not Used Max Circuit Current 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt Number. NAC #4 Panel ID: 5495 Ckt Name: Not Used MaxCircuitCurrent 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 STATEWIDE SECURITY FIRE ALARM EQUIPMENT SUBMITTAL FOR FIRE DETECTION SYSTEM FORT DENT III Therapeutic Associates Tenant Improvement TUKWILA, WASHINGTON July 14, 1999 A) D9412 Radionics 9412 Control/Communicator B) D8109 Radionics Auxiliary Fire Enclosure, Red C) D928 Radionics Dual Phone Line Switcher D) D122L Radionics Dual Battery Harness E) D192C Radionics Indicating Circuit Supervision Module F) D8132 Radionics Battery Charger Module G) D8004 Radionics Transformer Enclosure H) D1256 Radionics Fire Command Center I) D8125 Radionics Popex Module, Point Bus J) D411 Radionics Synchronization Module, 2 wire K) D443 Radionics 24V, Bell, 10" Shell L) D559S Radionics 24V, Synchronized Mini Horn Strobe, 15/75 cd M) D572S Radionics 24V, Horn Strobe, 110 cd N) D548S Radionics 24V, Strobe, 110 cd 0) WH114911 Wheelock 24V, Exterior Strobe P) SK5395 Silent Knight Super. Bell Circuit Pwr. Supply Prepared By: Statewide Security P.O. Box 2019 Redmond, WA 98052 Phone: 425-558-4640 Fax: 425-558-1290 P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 STATEWIDE SECURITY FIRE ALARM CALCULATIONS BATTERY BACK-UP TIME FORT DENT III Therapeutic Associates Tenant Improvement TUKWILA, WA July 14, 1999 FIRE PANEL: Silent Knight, SK5395 Supervised Bell Circuit Power Supply SK5395 75 MA (average current) x 24 Hours = 1.8 AMPS Subtotal 1.8 AMPS Horn/Strobes 1 @ .283 AMPS (average current) = .283 AMPS Strobes 2 @ .163 AMPS (average current) = 3.42 AMPS Subtotal = 3.70 AMPS Divided x 12 (5 min. ring) _ .31 AMPS Total Load 2.11 AMPS System has two (2) 12V, 7 A.H. Batteries in series for 7.0 A.H. Available @ 24 Volts. P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 STATEWIDE SECURITY Fort Dent!!! Therapeutic Associates Tenant Improvement Voltage Loss Calculations July 14, 1999 All conductors are 14 Ga. Solid copper core (12.9 constant), plenum rated, circular mil. Spec. of .4110 Horn/Stobe circuit #1: Not Used Horn/Strobe circuit #2; 6 Devices @ .163 Amperes ea. = .978 Amperes x 2(105'), x 12.9 divided by 4110 = .64 Volts of loss Horn/Strobe circuit #3: 1 Devices @ .177 Amperes ea. and 6 Devices @ .163 = 1.15 Amperes x 2(112') x 12.9, divided by 4110 = .81 Volts of loss. Horn/Strobe circuit #4: 9 Devices @ .163 Amperes ea. = 1.47 Amperes x 2(137'), x 12.9 divided by 4110 = 1.26 Volts of loss. P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 strnOJi0 aln6ijuoO Minimum Battery AmpHours Required Multiply By The Derating Factor Total Combined AH Required Total Standby AH Required Standby Time In Hours Total Standby Current (Amps) x Z n 1 NAC #3 1 NAC #2 Z n # it CT Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 15495 Aux Power Out 5495 Circuit 4 5495 Circuit 3 5495 Circuit 2 5495 Circuit 1 5495 Pwr Module 1 1 N k V 3 N O j O CS) Co O N A 0.075 0.000 0.000 O O 0 0.000 0.000 0.075 — Global Project Values: 1 Project Name: 'Mindful Therapy Standby Hours: 24 Project ID: Alarm Mins:1 5 Prepared By: Justin Gronberg Derating Factor: 1.2 Date: 1/9/2017 Voltage Drop Warning Threshold % 10 0 O co CJ 0 O— co W — - J 0 O O O- 0 N N 0 O 0 0 0 O 0 0- 0 Cr) co 0 N O CT Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Total Alarm AH Required Alarm Time In Minutes / 60 (5 Mins) Total Alarm Current (Amps) 4t N 0 a 4t A 0 a 4t N 0 a 4t N CO as 4t A 0 1.59 N in N) -a (T CO -a in CO N (T N r 250 O O O O O O O O O 0.00 -+ N co 20.40 1 1 20.40 1 N O A 0 20.40 1 _, CO in C) O O O 0 O O O 0 O O 0 0 O O OJ 0 A N 0 SILENT KNICIIT Circuit Configuration Project Information Project Name: Mindful Therapy Prepared By: Justin Gronberg Project ID: 0 Date: 1/9/2017 Ckt. Number: NAC #1 Panel ID: 5495 PS2 Ckt. Name: 5495 Circuit 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.352 1 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.116 2 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.132 1 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.091 0.000 0.000 Totals 0.000 0.691 Ckt. Number: NAC #2 Panel ID: 5495 PS2 Ckt. Name: 5495 Circuit 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: NAC #3 Panel ID: 5495 PS2 Ckt. Name: 5495 Circuit 3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: NAC #4 Panel ID: 5495 PS2 Ckt. Name: 5495 Circuit 4 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor P2/PC2 Horn/Strobe (110cd) 0.000 0.221 0.000 0.221 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.221 /." STATEWIDE SECURITY FIRE ALARM EQUIPMENT SUBMITTAL FOR FIRE DETECTION SYSTEM FORT DENT III University of Phoenix Tenant Improvement TUKWILA, WASHINGTON July 1, 1999 A) D9412 Radionics 9412 Control/Communicator* B) D8109 Radionics Auxiliary Fire Enclosure, Red* C) D928 Radionics Dual Phone Line Switcher* D) D122L Radionics Dual Battery Harness* E) D192C Radionics Indicating Circuit Supervision Module* F) D8132 Radionics Battery Charger Module* G) D8004 Radionics Transformer Enclosure* H) D1256 Radionics Fire Command Center* I) D8125 Radionics Popex Module, Point Bus* J) D411 Radionics Synchronization Module, 2 wire* K) D443 Radionics 24V, Bell, 10" Shell* L) D505S Radionics 24V, Synchronized Horn Strobe, 110 cd A M) D515 Radionics 24V, Remote Strobe, 30 cd A N) WH114911 Wheelock 24V, Exterior Strobe* 0) SK5395 Silent Knight Super. Bell Circuit Pwr. Supply A * Indicates units/devices installed in original permit for "Base" installation permit #99F069, completion date 04/15/99. A Indicates unit/devices installed for University of Phoenix Tenant Improvement. Prepared By: Statewide Security P.O. Box 2019 Redmond, WA 98052 Phone: 425-558-4640 Fax: 425-558-1290 P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 Fort Dent 3 University of Phoenix Tenant Improvement Voltage Loss Calculations All conductors are 14 Ga. Solid copper core (12.9 constant), plenum rated, circular mil. Spec. of .4110 Horn/Stobe circuit #1: 6 Devices @ .236 Amperes ea. = 1.41 Amperes x 2(120') x12.9 divided by 4110 = 1.06 Volts of loss. Horn/Strobe circuit #2: 4 Devices @ .236 Amperes ea. + 2 Devices @ .17 Amperes ea = 1.28 Amperes x 2(137') x 12.9 divided by 4110 = 1.10 Volts of loss Horn/Strobe circuit #3: 6 Devices @ .236 Amperes ea. = 1.41 Amperes x 2(135') x 12.9 divided by 4110 = 1.19 Volts of loss. Horn/Strobe circuit #4: 6 Devices @ .236 Amperes ea. + 1 Device @ .17 Amperes = 1.58 Amperes x 2(118') x 12.9 divided by 4110= 1.17 Volts of Toss. FIRE ALARM CALCULATIONS BATTERY BACK-UP TIME FORT DENT III TUKWILA, WA FIRE PANEL: Silent Knight, SK5395 Supervised Bell Circuit Power Supply SK5395 75 MA (average current) x 24 Hours Subtotal Horn/Strobes 22 @ .283 AMPS (average current) Strobes 3 @ .135 AMPS (average current) Bell 1 @ .056 AMPS (average current) Subtotal Divided x 12 (5 min. ring) Total Load = 1.8 AMPS 1.8 AMPS = 6.22 AMPS = .405 AMPS = .056 AMPS = 6.625 AMPS = .552 AMPS = 2.35 AMPS System has two (2) 12V, 7 A.H. Batteries in series for 7.0 A.H. Available @ 24 Volts. 1 Archer Cori structicork Inc _ 0 7855 South 206th St Kent, WA 98032 Date 07/15/99 Job: UOFPHON2 PROJECT INFORMATION Job_ UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Occupancy Ordinary Hazard Group I Density 0.15 gpm/sq.ft. Area of Operation 1500 square feet Area per Sprinkler 16X16 SPACING Authority having Jurisdiction_ _ NFPA-13 Hose 100.0 gpm Inside Hose, 100.0 gpm Outside Hose System type_ _ Wet Water Supply _ 155.00 psi Static, 105.00 psi Residual @ 1671.0 gpm Sprinklers _ _ Large Orifice CALCULATION SUMMARY Demand 97.27 psi @ 455.8 gpm @ B.O.R. 101.36 psi @ 655.8 gpm @ Supply 146.14 psi available @ 655.8 gpm Demand is below curve by 44.78 psi Notes: L Archer Construction Inc. Description of Fitting abbreviations Code .Description T Tee E Ninety degree elbow VE Victaulic ninety degree elbow B06 Backflow: Febco Backflow Model 805Y Dbl. Check Valve Assy. GV Gate valve Description of Other abbreviations Code Description AO Arm -over DR Drop BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction PV Velocity Pressure -.5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length uvr rnuty 1 No. Code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DR1 A01 A02 A03 BL1 BL1 BL1 BL1 BL2 BL2 BL2 BL2 CM1 CM1 CM1 RI1 BU1 RI2 UG1 UG1 ui/i3/i 3:tuam x Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT 7100 FORT DENT WAY Raw data previous Diam Length Kfacl 1.104 2.0 11.4 1.104 2.5 DR1 1.104 3.0 DR1 1.104 2.0 DR1 2.154 16.0 A02 2.154 16.0 A02 2.154 16.0 DR1 2.154 7.0 A03 2.154 16.0 A01 2.154 16.0 AO1 2.154 16.0 DR1 2.154 7.0 A03 3.352 16.0 BL1 3.352 29.0 BL2 3.352 37.0 3.352 11.5 CM1 3.352 217.0 RI1 4.352 11.5 BU1 8.270 70.0 RI2 8.270 0.0 .7i1CCC OI DENT 3 SECOND FLOOR TUKWILA, WA. to any calculations Kfac2 Press Elev Hose HW Vel Fittings 11.35 -2.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 A02 0.00 0.00 A02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 11.50 0.00 0.00 0.00 11.50 0.00 0.00 0.00 0.00 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 100.0 100.0 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 140 140 32 32 1E,1T 32 1E,1T 32 1E,1T 32 32 32 32 1T 32 32 32 32 1T 32 32 1VE 32 1VE 32 1VE 32 5VE 32 1GV,1E 32 1B06,1GV,1T 32 Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Drop 1 A 2.0 PT 11.35 1 Notes C = 120 38.4=11.40(11.35)'.5 F 0.0 PE -0.87 (EL= -2.00 ft) 1 38.4 1.10 T 2.0 0.33926 PF 0.68 12.87 PT 11.16 2 B1 Jct K -factor for drop 1 = 38.4/(11.16)'.5 = 11.49 at Hyd Ref Pts 2 3 4 7 11 Arm -over 1 C = 120 A 2.5 PT 11.16 2 DR1 38.4=11.49(11.16)".5 F 9.0 PE 0.00 2 38.4 1.10 1E 1T T 11.5 0.33917 PF 3.89 12.87 PT 15.06 9 B1 Jct K -factor for arm -over 1 = 38.4/(15.06)".5 = 9.90 at Hyd Ref Pts 9 10 Arm -over 2 C = 120 A 3.0 PT 11.16 3 DR1 38.4=11.49(11.16)'.5 F 9.0 PE 0.00 3 38.4 1.10 1E 1T T 12.0 0.33917 PF 4.06 12.87 PT 15.23 5 B1 Jct K -factor for arm -over 2 = 38.4/(15.23)"'.5 = 9.84 at Hyd Ref Pts 5 6 9 10 Arm -over 3 C = 120 A 2.0 PT 11.16 4 DR1 38.4=11.49(11.16)'.5 F 9.0 PE 0.00 4 38.4 1.10 1E 1T T 11.0 0.33917 PF 3.72 12.87 PT 14.89 8 B1 Jct K -factor for arm -over 3 = 38.4/(14.89)'.5 = 9.95 at Hyd Ref Pts 8 12 vva a aava• a. J • J. V dill Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations 1.714CCL OI UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 1 (Beginning pressure increased due to Hyd Ref Pt 6) C = 120 A 16.0 PT 15.33 5 A02 38.5=9.84(15.33)'.5 F 0.0 PE 0.00 5 38.5 2.15 T 16.0 0.01317 PF 0.21 3.39 A 16.0 PT 15.54 6 A02 38.4=9.84(15.23)'.5 F 0.0 PE 0.00 6 76.9 2.15 T 16.0 0.04732 PF 0.76 6.77 PV= 0.31 A 16.0 PT 16.30 7 DR1 45.3=11.49(15.52)'.5 F 0.0 PE 0.00 7 122.2 2.15 T 16.0 0.11140 PF 1.78 10.76 PV= 0.78 A 7.0 PT 18.08 8 A03 40.7=9.95(16.70)".5 F 12.2 PE 0.00 8 162.9 2.15 1T T 19.2 0.18954 PF 3.64 14.34 PV= 1.38 PT 21.72 13 Cross main Jct K -factor for branchline no. 1 = 162.9/(21.72)'.5 = 34.95 Branchline No. 2 (Beginning pressure increased due to Hyd Ref Pt 10) C = 120 K=19.74=9.90+9.84 A 16.0 PT 15.71 9 A01 + A02 78.2=19.74(15.71)'.5 F 0.0 PE 0.00 9 78.2 2.15 T 16.0 0.04881 PF 0.78 6.89 K=19.74=9.90+9.84 A 16.0 PT 16.49 10 AO1 + A02 77.0=19.74(15.24)".5 F 0.0 PE 0.00 10 155.3 2.15 T 16.0 0.17349 PF 2.78 13.67 PV= 1.26 A 16.0 PT 19.27 11 DR1 47.6=11.49(17.12)'.5 F 0.0 PE 0.00 11 202.8 2.15 T 16.0 0.28442 PF 4.55 17.86 PV= 2.15 A 7.0 PT 23.82 12 A03 45.2=9.95(20.61)".5 F 12.2 PE 0.00 12 248.0 2.15 1T T 19.2 0.41262 PF 7.93 21.84 PV= 3.21 PT 31.75 14 Cross main Jct K -factor for branchline no. 2 = 248.0/(31.75)'.5 = 44.01 Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 1 (Beginning pressure increased due to Hyd Ref Pt 14) C = 120 A 16.0 PT 33.02 13 BL1 200.9=34.95(33.02)'.5 F 0.0 PE 0.00 13 200.9 3.35 T 16.0 0.03241 PF 0.52 7.30 A 29.0 PT 33.54 14 BL2 254.9=44.01(33.54)".5 F 7.7 PE 0.00 14 455.8 3.35 1VE T 36.7 0.14759 PF 5.42 16.57 PV= 1.79 A 37.0 PT 38.96 15 F 7.7 PE 0.00 15 455.8 3.35 1VE T 44.7 0.14759 PF 6.60 16.57 PT 45.56 16 Top of Riser K -factor for Cross main 1 = 455.8/(45.56)".5 = 67.53 Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Riser 16 455.8 3.35 Notes C = 120 A 11.5 PT 45.56 16 Top of Riser F 7.7 PE 4.98 (EL= 11.50 ft) 1VE T 19.2 0.14762 PF 2.83 16.57 PT 53.37 17 B.O.R. Bulk C = 120 ___= A 217.0 PT 53.37 17 455.8=62.39(53.37)'.5 F 38.5 PE 0.00 17 455.8 3.35 5VE T 255.5 0.14762 PF 37.71 16.57 PT 91.08 18 Top of Riser Riser C = 120 A 11.5 PT 91.09 18 Top of Riser F 17.5 PE 4.98 (EL= 11.50 ft) 18 455.8 4.35 1GV lE T 29.0 0.04140 PF 1.20 9.83 PT 97.27 19 B.O.R. Under ground C = 140 A 70.0 PT 97.27 19 B.O.R. 100.0 gpm = Hose F 58.4 PE 0.00 19 555.8 8.27 1B06 1GV T 128.4 0.00197 PF 4.09 3.32 1B06 = 3.84# 1T A 0.0 PT 101.36 20 100.0 gpm = Hose F 0.0 PE 0.00 20 655.8 8.27 T 0.0 0.00000 PF 0.00 3.92 PT 101.36 21 Supply Jct Available flow at 101.36 psi is 1735.7 gpm which is 1079.9 gpm from curve. Supply pressure available with 655.8 gpm flowing is 146.14 psi, thus system requirement is 44.78 psi below supply curve. (30.6%) UOFPHON2 07/15/99 3:10am Sneez Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Node Detail Discharge Pressure Outlet (psi) K -Value Source Node (gpm) Elevation (ft) Comments 1 38.4 2 38.4 3 38.4 4 38.4 5 38.5 6 38.4 7 45.3 8 40.7 9 78.2 10 77.0 11 47.6 12 45.2 13 14 15 16 17 18 19 100.0 20 100.0 21 11.35 Orif=11.40 11.16 K=11.49 11.16 K=11.49 11.16 K=11.49 15.33 K= 9.84 15.54 K= 9.84 16.30 K=11.49 18.08 K= 9.95 15.71 K=19.74 16.49 K=19.74 19.27 K=11.49 23.82 K= 9.95 33.02 33.54 38.96 45.56 53.37 91.09 97.27 Hose 101.36 Hose 101.36 DR1 DR1 DR1 AO2 AO2 DR1 AO3 AO1 AO1 DR1 AO3 RI2 Pv=0.31 Pv=0.78 Pv=1.38 + AO2 + AO2 Pv=1.26 Pv=2.15 Pv=3.21 Supply 21.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 11.50 11.50 0.00 0.00 0.00 UOFPHON2 07/15/99 3:10am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Pipe Detail Actual Total Elev Fric Fric Press Press Pipe Diam Len Len Head Flow Loss Loss Vel Nodes @ Beg @ End No. (inch) (Ft) (Ft) (Ft) (Gpm)(Psi/Ft)(Psi)(Fps) Beg End (Psi) (Psi) 1 1.10 2.0 2.0 -2.00 38.4 0.3393 0.68 12.9 1 2 11.35 11.16 2 1.10 2.5 11.5 0.00 38.4 0.3392 3.89 12.9 2 9 11.16 15.71 Fit= 9.0 1E 1T 3 1.10 3.0 12.0 0.00 38.4 0.3392 4.06 12.9 3 5 11.16 15.33 Fit= 9.0 lE 1T 4 1.10 2.0 11.0 0.00 38.4 0.3392 3.72 12.9 4 8 11.16 18.08 Fit= 9.0 lE 1T 5 2.15 16.0 16.0 0.00 38.5 0.0132 0.21 3.4 5 6 15.33 15.54 6 2.15 16.0 16.0 0.00 76.9 0.0473 0.76 6.8 6 7 15.54 16.30 7 2.15 16.0 16.0 0.00 122.2 0.1114 1.78 10.8 7 8 16.30 18.08 8 2.15 7.0 19.2 0.00 162.9 0.1895 3.64 14.3 8 13 18.08 33.02 Fit= 12.2 1T 9 2.15 16.0 16.0 0.00 78.2 0.0488 0.78 6.9 9 10 15.71 16.49 10 2.15 16.0 16.0 0.00 155.3 0.1735 2.78 13.7 10 11 16.49 19.27 11 2.15 16.0 16.0 0.00 202.8 0.2844 4.55 17.9 11 12 19.27 23.82 12 2.15 7.0 19.2 0.00 248.0 0.4126 7.93 21.8 12 14 23.82 33.54 Fit= 12.2 1T 13 3.35 16.0 16.0 0.00 200.9 0.0324 0.52 7.3 13 14 33.02 33.54 14 3.35 29.0 36.7 0.00 455.8 0.1476 5.42 16.6 14 15 33.54 38.96 Fit= 7.7 1VE 15 3.35 37.0 44.7 0.00 455.8 0.1476 6.60 16.6 15 16 38.96 45.56 Fit= 7.7 1VE 16 3.35 11.5 19.2 11.50 455.8 0.1476 2.83 16.6 16 17 45.56 53.37 Fit= 7.7 1VE 17 3.35 217.0 255.5 0.00 455.8 0.1476 37.71 16.6 17 18 53.37 91.09 Fit= 38.5 5VE 18 4.35 11.5 29.0 11.50 455.8 0.0414 1.20 9.8 18 19 91.09 97.27 Fit= 17.5 1GV 1E 19 8.27 70.0 128.4 0.00 555.8 0.0020 0.25 3.3 19 20 97.27 101.36 Fit= 58.4 1B06 1GV 1T 20 8.27 0.0 0.0 0.00 655.8 0.0027 0.00 3.9 20 21 101.36 101.36 STATEWIDE SECURITY FIRE ALARM EQUIPMENT SUBMITTAL FOR FIRE DETECTION SYSTEM FORT DENT III University of Phoenix Tenant Improvement Phase II TUKWILA, WASHINGTON July 14, 1999 A) D9412 Radionics 9412 Control/Communicator B) D8109 Radionics Auxiliary Fire Enclosure, Red C) D928 Radionics Dual Phone Line Switcher D) D122L Radionics Dual Battery Harness E) D192C Radionics Indicating Circuit Supervision Module F) D8132 Radionics Battery Charger Module G) D8004 Radionics Transformer Enclosure H) D1256 Radionics Fire Command Center I) D8125 Radionics Popex Module, Point Bus J) D411 Radionics Synchronization Module, 2 wire K) D443 Radionics 24V, Bell, 10" Shell L) D559S Radionics 24V, Synchronized Mini Horn Strobe, 15/75 cd M) D572S Radionics 24V, Horn Strobe, 110 cd N) D548S Radionics 24V, Strobe, 110 CD 0) WH114911 Wheelock 24V, Exterior Strobe P) SK5395 Silent Knight Super. Bell Circuit Pwr. Supply Prepared By: Statewide Security P.O. Box 2019 Redmond, WA 98052 Phone: 425-558-4640 Fax: 425-558-1290 P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 STATEWIDE SECURITY FIRE ALARM CALCULATIONS BATTERY BACK-UP TIME FORT DENT III University of Phoenix Phase II Tenant Improvement TUKWILA, WA July 14, 1999 FIRE PANEL: Silent Knight, SK5395 Supervised Bell Circuit Power Supply SK5395 75 MA (average current) x 24 Hours = 1.8 AMPS Subtotal 1.8 AMPS Horn/Strobes 1 @ .283 AMPS (average current) = .283 AMPS Strobes 2 @ .163 AMPS (average current) = 3.42 AMPS Subtotal = 3.70 AMPS Divided x 12 (5 min. ring) _ .31 AMPS Total Load 2.11 AMPS System has two (2) 12V, 7 A.H. Batteries in series for 7.0 A.H. Available @ 24 Volts. P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 L 1 STATEWIDE SECURITY 1 Fort Dent I11 University of Phoenix Phase II Tenant Improvement Voltage Loss Calculations July 14, 1999 All conductors are 14 Ga. Solid copper core (12.9 constant), plenum rated, circular mil. Spec. of .4110 Horn/Stobe circuit #1: Not Used Horn/Strobe circuit #2; 6 Devices @ .163 Amperes ea. = .978 Amperes x 2(105'), x 12.9 divided by 4110 = .64 Volts of loss Horn/Strobe circuit #3: 1 Devices @ .177 Amperes ea. and 6 Devices @ .163 = 1.15 Amperes x 2(112') x 12.9, divided by 4110 = .81 Volts of loss. Horn/Strobe circuit #4: 9 Devices @ .163 Amperes ea. = 1.47 Amperes x 2(137'), x 12.9 divided by 4110 = 1.26 Volts of loss. P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 .31&,-‘il 1 S71711111% 2700 Richards Road, Suite 202 Bellevue, WA 98005 June 1, 2008 FORT DENT OFFICE BUILDNG III - UNIVERSITY OF PHOENIX Equipment Bill of Materials QUANTITY MANUFACTURER MODEL NO. DESCRIPTION 1 BOSCH D9412 FIRE ALARM CONTROL PANEL 3 SILENT KNIGHT 5395 3 AMP POWER SUPPLY 22 WHEELOCK MT-24MCW-FR HORN/STROBE 3 WHEELOCK RSS-24MCW-FR STROBE 4 BOSCH FMM-100SATK PULL STATION 2 BOSCH D263 SMOKE DETECTOR 1 BOSCH D1256 ANNUNCIATOR Scope of Work 1. This installation is a relocation of all existing devices. All devices used in this installation are existing and are being relocated to meet new code requirements and to satisfy coverage for the tenant improvement. 2. Reuse existing fire alarm control panel located in the electrical room. 3. Reuse existing Power Supplies located next to the FACP and in the storage room. 4. Relocate all notification devices to meet coverage requirements. 5. Relocate all SLC device to meet coverage requirements. 6. Connect all relocated existing devices to Fire Alarm Control Panel and Notification Control Panel. Honeywell Security Monitoring Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building FACP Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Bosch 09412 Fire Alarm System 1 150 300 150 300 Bosch D1256 Annunciator 1 104 206 104 206 2.2 2.2 508.44 Total System Standby NH 0 0 0 0 0.04 Min. A/H Battery 2 0 0 0 1.86 Required NH Battery 0 0 Total System Current 0 0 254 506 Smoke Detectors / Auxiliary Devices Bosch D263 Smoke Detector 2 0.08 0.12 0.16 0.24 Bosch FMM-100SATK Pull Station 4 0.55 0.55 2.2 2.2 508.44 Total System Standby NH N/A 6.15 0 0 0.04 Min. A/H Battery N/A 6.20 0 0 1.86 Required NH Battery N/A ' 8.05 0 0 0 0 0 0 0 0 N/A 0 0 Device Totals 6 2.36 2.44 Notification Appliances (list all) Standby Hrs. Required N/A 24 N/A 0 5 Total System Standby mA N/A 256.36 N/A 0 508.44 Total System Standby NH N/A 6.15 N/A 0 0.04 Min. A/H Battery N/A 6.20 N/A 0 1.86 Required NH Battery N/A ' 8.05 N/A 0 N/A N/A 0 0 N/A N/A 0 Notification Appliance Totals 0 N/A 0 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 256.36 Total System Alarm mA 508.44 Total System Standby NH 6.15 Total System Alarm AIH 0.04 Min. A/H Battery 6.20 ADD 30% FOR BATTERY DEPLETION 1.86 Required NH Battery ' 8.05 AIH BATTERY PROVIDED FOR SYSTEM I 12 ' Honeywell Security Monitoring Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #1 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Silent Knight 5395 NAC Panel 1 75 175 75 175 0 0 MT-24MCW-FR Hom/Strobe 30cd 4 0 0 0 0 MT-24MCW-FR Hom/Strobe 75cd 7 0 0 0 0 MT-24MCW-FR Hom/Strobe 110cd 1 0 0 0 0 RSS-24MCW-FR Strobe 15cd 1 0 0 Total System Current 0 RSS-24MCW-FR Strobe 30cd 0 75 175 Smoke Detectors / Auxiliary Devices MT-24MCW-FR Hom/Strobe 15cd N/A 41 0 0 MT-24MCW-FR Hom/Strobe 30cd 4 N/A 63 0 0 MT-24MCW-FR Hom/Strobe 75cd 7 N/A 109 0 0 MT-24MCW-FR Hom/Strobe 110cd 1 N/A 140 0 0 RSS-24MCW-FR Strobe 15cd 1 N/A 60 0 0 RSS-24MCW-FR Strobe 30cd 0 0 0 0 0 I 6.00 0 N/A 0 0 Device Totals 0 N/A 0 0 Notification Appliances (list all) MT-24MCW-FR Hom/Strobe 15cd N/A 41 N/A 0 MT-24MCW-FR Hom/Strobe 30cd 4 N/A 63 N/A 252 MT-24MCW-FR Hom/Strobe 75cd 7 N/A 109 N/A 763 MT-24MCW-FR Hom/Strobe 110cd 1 N/A 140 N/A 140 RSS-24MCW-FR Strobe 15cd 1 N/A 60 N/A 60 RSS-24MCW-FR Strobe 30cd N/A 92 N/A 0 I 6.00 I N/A N/A 0 N/A N/A 0 N/A N/A 0 Notification Appliance Totals 13 N/A 1215 Summary Section Standby Hrs. Required 60 Alarm Sounding Minutes 5 Total System Standby mA 75 Total System Alarm mA 1390 Total System Standby AIH 4.50 Total System Alarm A/H 0.12 Min. A/H Battery 4.62 ADD 30% FOR BATTERY DEPLETION 1.38 Required NH Battery I 6.00 I A/H BATTERY PROVIDED FOR SYSTEM 7 Honeywell Security Monitoring Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #2 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Silent Knight 5395 NAC Panel 1 75 175 75 175 0 0 MT-24MCW-FR Horn/Strobe 30cd 2 0 0 0 0 MT-24MCW-FR Horn/Strobe 75cd 4 0 0 0 0 MT-24MCW-FR Horn/Strobe 110cd Min. A/H Battery 0 0 0 0 RSS-24MCW-FR Strobe 15cd Required A/H Battery 0 0 Total System Current 0 RSS-24MCW-FR Strobe 30cd 0 75 175 Smoke Detectors / Auxiliary Devices MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 0 0 MT-24MCW-FR Horn/Strobe 30cd 2 N/A 63 0 0 MT-24MCW-FR Horn/Strobe 75cd 4 N/A 109 0 0 MT-24MCW-FR Horn/Strobe 110cd Min. A/H Battery N/A 140 0 0 RSS-24MCW-FR Strobe 15cd Required A/H Battery N/A 60 0 0 RSS-24MCW-FR Strobe 30cd 0 0 0 0 0 0 N/A 0 0 Device Totals 0 N/A 0 0 Notification Appliances (list all) MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 N/A 0 MT-24MCW-FR Horn/Strobe 30cd 2 N/A 63 N/A 126 MT-24MCW-FR Horn/Strobe 75cd 4 N/A 109 N/A 436 MT-24MCW-FR Horn/Strobe 110cd Min. A/H Battery N/A 140 N/A 0 RSS-24MCW-FR Strobe 15cd Required A/H Battery N/A 60 N/A 0 RSS-24MCW-FR Strobe 30cd N/A 92 N/A 0 N/A N/A 0 N/A N/A 0 N/A N/A 0 Notification Appliance Totals 6 N/A 562 Summary Section Standby Hrs. Required 60 Alarm Sounding Minutes 5 Total System Standby mA 75 Total System Alarm mA 737 Total System Standby AIH 4.50 Total System Alarm A/H 0.06 Min. A/H Battery 4.56 ADD 30% FOR BATTERY DEPLETION 1.37 Required A/H Battery 1 5.93 , A/H BATTERY PROVIDED FOR SYSTEM 7 Honeywell Security Monitoring Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #3 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Silent Knight 5395 NAC Panel 1 75 175 75 175 0 0 MT-24MCW-FR Hom/Strobe 30cd 1 0 0 0 0 MT-24MCW-FR Hom/Strobe 75cd 1 0 0 0 0 MT-24MCW-FR HomlStrobe 110cd 2 0 0 0 0 RSS-24MCW-FR Strobe 15cd 2 0 0 Total System Current 0 RSS-24MCW-FR Strobe 30cd 0 75 175 Smoke Detectors / Auxiliary Devices MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 0 0 MT-24MCW-FR Hom/Strobe 30cd 1 N/A 63 0 0 MT-24MCW-FR Hom/Strobe 75cd 1 N/A 109 0 0 MT-24MCW-FR HomlStrobe 110cd 2 N/A 140 0 0 RSS-24MCW-FR Strobe 15cd 2 N/A 60 0 0 RSS-24MCW-FR Strobe 30cd 0 0 0 0 0 0 N/A 0 0 Device Totals 0 N/A 0 0 Notification Appliances (list all) MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 N/A 0 MT-24MCW-FR Hom/Strobe 30cd 1 N/A 63 N/A 63 MT-24MCW-FR Hom/Strobe 75cd 1 N/A 109 N/A 109 MT-24MCW-FR HomlStrobe 110cd 2 N/A 140 N/A 280 RSS-24MCW-FR Strobe 15cd 2 N/A 60 N/A 120 RSS-24MCW-FR Strobe 30cd N/A 92 N/A 0 N/A N/A 0 N/A N/A 0 N/A N/A 0 Notification Appliance Totals 6 N/A 572 Summary Section Standby Hrs. Required 60 Alarm Sounding Minutes 5 Total System Standby mA 75 Total System Alarm mA 747 Total System Standby A/H 4.50 Total System Alarm A/H 0.06 Min. A/H Battery 4.56 ADD 30% FOR BATTERY DEPLETION 1.37 Required A/H Battery 1 5.93 A/H BATTERY PROVIDED FOR SYSTEM 7 FORT DENT OFFICE BUILDING 11I - UNIVERSITY OF PHOENIX O w 0r. ci X O C C Of Of ■ ■ O o0 m 0 wvi w co w N c1') C X CI 8 O C C Of O Y) — • v) C c • c o 0 N 0Ic4 a Of N O N O X 41, vi 8 C C Oa N N m c0 C ■ N G X c+) C C as N r e ■ c • c c c o � N N cE Na 4. 7 CO O N O CO c V 0 O cp 0 0 0 0 0 1 0 Total Current 0.544 Current 1 j# of Devices I I Current I CO 0 O Na 3 0 G 0 0 0 0 1 0 Total Current 0.671 Current 1 1 # of Devices ' 1 Current I ccc+p) 0 O 0 co N c `) 0 0 c 0 0 0 0 N 0 ND G Current 1 1 # of Devices ' ' Current I CO 01 O CO 0 0 C 0 0 0 0 1 0 1 Total Current 0.562 NNIIINUNIUO E S F N N N N II N N N Current 1 1 # of Devices 1 p N N■ p■■ M N O " N N N N N N c- X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X o8e°°0 D o G d D D 000000 o D o - D O 000000 o o O D O 0o600$ 0 O O , D O xm a j MT-24MCW-FR HomlStrobe 15cd MT-24MCW-FR HomlStrobe 30cd MT-24MCW-FR Horn/Strobe 750 M7-24MCW-FR Nom/Strobe 110cd cc cc 4 4K NN 6 O: NACP #1 Device MT-24MCW-FR HomlStrobe 75cd 51T-24MCW-FR HomlStrobe 30cd MT-24MCW-FR HomlStrobe 75cd MT-24MCW-FR HomlStrobe 110cd RSS-24MCW-FR Strobe 75cd RSS-24MCW-FR Strobe 30cd 8 V > MT-24MCW-FR Hom/Strobe 75cd MT-24MCW-FR Nom/Strobe 30cd MT-24MCW-FR Horn/Strobe 75cd MT-24MCW-FR HomlStrobe 110cd RSS-24MCW-FR Strobe 75cd RSS-24MCW-FR Strobe 30cd NACP #3 Device u x i LL 4 MT-241ACW-FR Hom!Strobe 75cd MT-24MCW-FR Horn/Strobe 110cd RSS-24MCW-FR Strobe 75cd RSS-24MCW-FR Strobe 30cd aU Panel Circuit Panel Circuit O•u FIRE ALARM CALCULATIONS BATTERY BACK-UP TIME FORT DENT III TUKWILA, WA FIRE PANEL: Radionics D9412 Control Communicator Radionics D928 Dual Phone Line Switcher Radionics D192 Indicating Circuit Supervision Module Radionics D1256 Keypad Radionics D9127U ASIC Popit Module's 11 @ 3 MA Radionics D125B Powered Loop Interface Module 250 MA 18 MA 25 MA 108 MA 33 MA 35 MA .469 MA X 24 Hours =11.3 AMP Hour Draw System has two 7.0 A.H. Batterie , = 14.0 AMP Hours Available Silent Knight, SK5395 Supervised Bell Circuit Power Supply SK5395 Horn/Strobes Strobes Bell 75 MA (average current) x 24 Hours Subtotal 14 @ .283 AMPS (average current) 5 @ .135 AMPS (average current) 1 @ .056 AMPS (average current) Subtotal Divided x 12 Subtotal Total = 1.8 AMPS 1.8 AMPS • 3.96 AMPS _ .675 AMPS .056 AMPS • 4.691 AMPS .390 AMPS .390 AMPS (5 minute) = 2.19 AMPS System has two (2) 12V, 7 A.H. Batteries in series for 7.0 A.I1. Available @ 24 Volts. Archer Coristructzcork Imc _ 0 7855 South 206th St Kent, WA 98032 Date 06/23/99 Job: UOFPHONX PROJECT INFORMATION Job_ UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. J Occupancy Ordinary Hazard Group I Density 0.15 gpm/sq.ft. Area of Operation 1500 square feet Area per Sprinkler 16X16 SPACING Authority having Jurisdiction_ _ NFPA-13 Hose 100.0 gpm Inside Hose, 100.0 gpm Outside Hose System type_ _ Wet Water Supply _ 155.00 psi Static, 105.00 psi Residual @ 1671.0 gpm Sprinklers _ _ Large Orifice CALCULATION SUMMARY Demand 113.42 psi @ 568.4 gpm @ B.O.R. 117.69 psi @ 768.4 gpm @ Supply 143.12 psi available @ 768.4 gpm Demand is below curve by 25.43 psi Notes: __oria+. I>K. +a G oCetinCite #F>. os IL 11 COO`i> Sheet of Archer Construction Inc. Description of Fitting abbreviations Code Description T Tee E Ninety degree elbow VT Victaulic tee VE Victaulic ninety degree elbow B06 Backflow: Febco Backflow Model 805Y Dbl. Check Valve Assy. GV Gate valve Description of Other abbreviations Code Description AO Arm -over DR Drop BL Branch Line RN Riser Nipple CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction PV Velocity Pressure -.5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length UOFPHONX 06/23/99 0:52am Sheet No. Code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 DR1 DR2 AO1 BL1 BL1 BL1 BL1 BL1 BL2 BL2 BL3 BL3 BL3 BL3 BL3 RN1 RN2 RN3 CM1 CM1 CM1 BU1 RI1 UG1 UG1 Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Raw data previous to any calculations Diam Length Kfacl 1.104 2.0 11.4 1.104 2.0 11.4 1.104 2.0 DR2 1.687 13.0 DR1 1.687 3.0 DR1 1.687 16.0 AO1 1.687 14.0 AO1 1.687 7.0 DR1 1.687 11.0 DR1 1.687 16.5 DR1 1.687 16.0 DR1 1.687 8.0 DRI 1.687 8.0 DR1 1.687 14.0 AO1 1.687 7.0 DR1 1.687 1.0 BL1 1.687 1.0 BL2 1.687 1.0 BL3 3.352 8.0 RN1 3.352 8.0 RN2 3.352 148.0 RN3 3.352 13.0 CM1 4.352 11.0 BU1 8.270 70.0 RI1 8.270 0.0 Kfac2 Press Elev 11.40 -2.00 11.40 -2.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 11.00 0.00 0.00 0.00 0.00 of Hose HW Vel Fittings 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 100.0 100.0 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 140 140 32 1T 32 lE 32 1T 32 32 32 32 32 1T 32 32 1T 32 32 32 32 32 1T 32 1T 32 1T 32 1T 32 32 32 1VT 32 2VE 32 1GV,1E 32 1B06,1GV,1T 32 UOFPHONX 06/23/99 0:52am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Drop 1 C = 120 A 2.0 PT 11.40 1 38.5=11.40(11.40)'.5 F 6.4 PE -0.87 (EL= -2.00 ft) 1 38.5 1.10 1T T 8.4 0.34065 PF 2.86 12.90 PT 13.40 4 B1 Jct K -factor for drop 1 = 38.5/(13.40)".5 = 10.52 at Hyd Ref Pts 4 5 8 9 10 11 12 13 15 Drop 2 C = 120 A 2.0 PT 11.40 2 38.5=11.40(11.40)'.5 F 2.6 PE -0.87 (EL= -2.00 ft) 2 38.5 1.10 lE T 4.6 0.34065 PF 1.56 12.90 PT 12.09 3 B1 Jct K -factor for drop 2 = 38.5/(12.09)'.5 = 11.07 Arm -over 1 C = 120 A 2.0 PT 12.09 3 DR2 38.5=11.07(12.09)-.5 F 6.4 PE 0.00 3 38.5 1.10 1T T 8.4 0.34080 PF 2.87 12.90 PT 14.96 6 B1 Jct K -factor for arm -over 1 = 38.5/(14.96)"'.5 = 9.95 at Hyd Ref Pts 6 7 14 UOFPHONX 06/23/99 0:52am Sheet Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting No (gpm) (inch) and Dev Branchline No. 1 (Beginning Length Fr Loss Press Hyd Vel (ft) (psi/ft) (psi) Ref (fps) pressure increased due A 13.0 PT 0.0 PE 13.0 0.05040 PF 3.0 PT 0.0 PE 3.0 0.18008 PF 16.0 PT 0.0 PE 16.0 0.36379 PF 14.0 PT 0.0 PE 14.0 0.63977 PF 7.0 PT 10.0 PE 17.0 1.06864 PF PT 41.8=10.52(15.82)'.5 F 4 41.8 1.69 T A 41.4=10.52(15.51)'.5 F 5 83.3 1.69 T A 38.5=9.95(14.96)'.5 F 6 121.8 1.69 T A 43.5=9.95(19.05)'.5 F 7 165.2 1.69 T A 52.8=10.52(25.20)'.5 F 8 218.0 1.69 1T T K -factor for branchline no. 1 = to Hyd Ref Pt 6) 15.82 4 0.00 0.66 6.00 16.48 5 0.00 0.54 11.95 17.02 6 0.00 5.82 17.48 22.84 7 0.00 8.96 23.72 31.79 8 0.00 18.21 31.29 50.00 16 Riser 218.0/(50.00)'.5 = 30.83 Riser Nipple (Top of RN =Branchline 1) A 1.0 PT 218.0=30.83(50.01)'.5 F 10.0 PE 16 218.0 1.69 1T T 11.0 1.06846 PF PT 50.01 0.43 11.80 62.23 K -factor for riser nipple = 218.0/(62.23)'.5 = 27.63 Branchline No. 2 (Beginning 39.0=10.52(13.75)".5 9 39.0 1.69 38.5=10.52(13.41)".5 10 77.5 1.69 1T pressure A F T A F T increased due 11.0 PT 0.0 PE 11.0 0.04428 PF 16.5 PT 10.0 PE 26.5 0.15777 PF PT K -factor for branchline no. 2 = Riser Nipple (Top of RN =Branchline 2) A 77.5=18.05(18.43)".5 F 17 77.5 1.69 1T T of Notes C = 120 DR1 DR1 PV= 0.96 AO1 PV= 2.06 AO1 PV= 3.78 DR1 PV= 6.59 Nipple Jct C = 120 BL1 ft) 16 (EL= 1.00 31.29 19 Cross main Jct to Hyd Ref Pt 10) 13.75 9 0.00 0.49 5.60 14.24 10 0.00 4.19 11.13 18.43 17 Riser 77.5/(18.43)'.5 = 18.05 1.0 PT 10.0 PE 11.0 0.15769 PF PT 18.43 0.43 1.74 20.60 K -factor for riser nipple =77.5/(20.60)'.5 = 17.07 C = 120 DR1 DR1 PV= 0.83 Nipple Jct C = 120 17 BL2 (EL= 1.00 ft) 11.12 20 Cross main Jct UOFPHONX 06/23/99 0:52am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of s UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 3 (Beginning pressure increased due to Hyd Ref Pt 14) C = 120 A 16.0 PT 13.65 11 DR1 38.9=10.52(13.65)'.5 F 0.0 PE 0.00 11 38.9 1.69 T 16.0 0.04397 PF 0.70 5.58 A 8.0 PT 14.35 12 DR1 38.7=10.52(13.52)'.5 F 0.0 PE 0.00 12 77.5 1.69 T 8.0 0.15781 PF 1.26 11.13 PV= 0.83 A 8.0 PT 15.61 13 DR1 39.0=10.52(13.73)'.5 F 0.0 PE 0.00 13 116.5 1.69 T 8.0 0.33525 PF 2.68 16.72 PV= 1.88 A 14.0 PT 18.30 14 AO1 38.5=9.95(14.97)'.5 F 0.0 PE 0.00 14 155.0 1.69 T 14.0 0.56860 PF 7.96 22.25 PV= 3.33 A 7.0 PT 26.26 15 DR1 47.7=10.52(20.56)".5 F 10.0 PE 0.00 15 202.7 1.69 1T T 17.0 0.93393 PF 15.91 29.10 PV= 5.70 Nipple Jct PT 42.17 18 Rise K -factor for branchline no. 3 = 202.7/(42.17)".5 = 31.21 Riser Nipple (Top of RN =Branchline 3) C = 120 A 1.0 PT 42.17 18 BL3 202.7=31.21(42.17)'.5 F 10.0 PE 0.43 (EL= 1.00 ft) 18 202.7 1.69 1T T 11.0 0.93387 PF 10.31 29.09 PT 52.91 21 Cross main Jct K -factor for riser nipple = 202.7/(52.91)'.5 = 27.87 UOFPHONX 06/23/99 0:52am Pipe Flow No (gpm) Cross main 1 Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Dia Fitting (inch) and Dev 218.0=27.63(62.23)".5 19 218.0 3.35 133.8=17.07(61.43)'.5 20 351.8 3.35 216.6=27.87(60.39)'.5 21 568.4 3.35 1VT Length Fr Loss Press Hyd Vel (ft) (psi/ft) (psi) Ref (fps) A 8.0 PT F 0.0 PE T 8.0 0.03772 PF A 8.0 PT F 0.0 PE T 8.0 0.09144 PF A 148.0 PT F 20.0 PE T 168.0 0.22208 PF PT K -factor for Cross main 1 62.23 19 0.00 0.30 62.54 20 0.00 0.73 63.27 21 0.00 37.31 100.58 22 = 568.4/(100.58)'.5 = 56.68 7.93 12.79 20.66 Notes C = 120 RN#16 RN#17 PV= 1.10 RN#18 PV= 2.87 Bulk Jct UOFPHONX 06/23/99 0:52am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Bulk C = 120 ___= A 13.0 PT 100.58 22 CM 1 568.4=56.68(100.58)".5 F 15.4 PE 0.00 22 568.4 3.35 2VE T 28.4 0.22209 PF 6.31 20.67 PT 106.88 23 Top of Riser Riser C = 120 A 11.0 PT 106.88 23 Top of Riser F 17.5 PE 4.76 (EL= 11.00 ft) 23 568.4 4.35 1GV 1E T 28.5 0.06228 PF 1.78 12.26 PT 113.42 24 B.O.R. Under ground C = 140 A 70.0 PT 113.42 24 B.O.R. 100.0 gpm = Hose F 58.4 PE 0.00 24 668.4 8.27 1B06 1GV T 128.4 0.00277 PF 4.27 3.99 1B06 = 3.91* 1T A 0.0 PT 117.69 25 100.0 gpm = Hose F 0.0 PE 0.00 25 768.4 8.27 T 0.0 0.00000 PF 0.00 4.59 PT 117.69 26 Supply Jct Available flow at 117.69 psi is 1426.4 gpm which is 658.0 gpm from curve. Supply pressure available with 768.4 gpm flowing is 143.12 psi, thus system requirement is 25.43 psi below supply curve. (17.8%) UOFPHONX 06/23/99 0:52am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) . 7100 FORT DENT WAY TUKWILA, WA. Node Detail Discharge Pressure Outlet Elevation (ft) Comments Node (gpm) (psi) K -Value Source 1 38.5 2 38.5 3 38.5 4 41.8 5 41.4 6 38.5 7 43.5 8 52.8 9 39.0 10 38.5 11 38.9 12 38.7 13 39.0 14 38.5 15 47.7 16 17 18 19 20 21 22 23 24 100.0 25 100.0 26 11.40 Orif=11.40 11.40 Orif=11.40 12.09 K=11.07 15.82 K=10.52 16.48 K=10.52 17.02 K= 9.95 22.84 K= 9.95 31.79 K=10.52 13.75 K=10.52 14.24 K=10.52 13.65 K=10.52 14.35 K=10.52 15.61 K=10.52 18.30 K= 9.95 26.26 K=10.52 50.01 18.43 42.17 62.23 62.54 63.27 100.58 106.88 113.42 Hose 117.69 Hose 117.69 DR2 DR1 DR1 Pv=0.96 AO1 Pv=2.06 AO1 Pv=3.78 DR1 Pv=6.59 DR1 DR1 Pv=0.83 DR1 DR1 Pv=0.83 DR1 Pv=1.88 AO1 Pv=3.33 DR1 Pv=5.70 RI1 Supply 10.00 10.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 11.00 11.00 11.00 11.00 11.00 0.00 0.00 0.00 UOFPHONX 06/23/99 0:52am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Detail Actual Total Elev Fric Fric Press Press Pipe Diam Len Len Head Flow Loss Loss Vel Nodes @ Beg @ End No. (inch) (Ft) (Ft) (Ft) (Gpm)(Psi/Ft)(Psi)(Fps) Beg End (Psi) (Psi) 1 1.10 2.0 8.4 -2.00 38.5 0.3406 2.86 12.9 1 4 11.40 15.82 Fit= 6.4 1T 2 1.10 2.0 4.6 -2.00 38.5 0.3406 1.56 12.9 2 3 11.40 12.09 Fit= 2.6 lE 3 1.10 2.0 8.4 0.00 38.5 0.3408 2.87 12.9 3 6 12.09 17.02 Fit= 6.4 1T 4 1.69 13.0 13.0 0.00 41.8 0.0504 0.66 6.0 4 5 15.82 16.48 5 1.69 3.0 3.0 0.00 83.3 0.1801 0.54 12.0 5 6 16.48 17.02 6 1.69 16.0 16.0 0.00 121.8 0.3638 5.82 17.5 6 7 17.02 22.84 7 1.69 14.0 14.0 0.00 165.2 0.6398 8.96 23.7 7 8 22.84 31.79 8 1.69 7.0 17.0 0.00 218.0 1.0686 18.21 31.3 8 16 31.79 50.01 Fit= 10.0 1T 9 1.69 11.0 11.0 0.00 39.0 0.0443 0.49 5.6 9 10 13.75 14.24 10 1.69 16.5 26.5 0.00 77.5 0.1578 4.19 11.1 10 17 14.24 18.43 Fit= 10.0 1T 11 1.69 16.0 16.0 0.00 38.9 0.0440 0.70 5.6 11 12 13.65 14.35 12 1.69 8.0 8.0 0.00 77.5 0.1578 1.26 11.1 12 13 14.35 15.61 13 1.69 8.0 8.0 0.00 116.5 0.3352 2.68 16.7 13 14 15.61 18.30 14 1.69 14.0 14.0 0.00 155.0 0.5686 7.96 22.3 14 15 18.30 26.26 15 1.69 7.0 17.0 0.00 202.7 0.9339 15.91 29.1 15 18 26.26 42.17 Fit= 10.0 1T 16 1.69 1.0 11.0 1.00 218.0 1.0685 11.80 31.3 16 19 50.01 62.23 Fit= 10.0 1T 17 1.69 1.0 11.0 1.00 77.5 0.1577 1.74 11.1 17 20 18.43 62.54 Fit= 10.0 1T 18 1.69 1.0 11.0 1.00 202.7 0.9339 10.31 29.1 18 21 42.17 63.27 Fit= 10.0 1T 19 3.35 8.0 8.0 0.00 218.0 0.0377 0.30 7.9 19 20 62.23 62.54 20 3.35 8.0 8.0 0.00 351.8 0.0914 0.73 12.8 20 21 62.54 63.27 21 3.35 148.0 168.0 0.00 568.4 0.2221 37.31 20.7 21 22 63.27 100.58 Fit= 20.0 1VT 22 3.35 13.0 28.4 0.00' 568.4 0.2221 6.31 20.7 22 23 100.58 106.88 Fit= 15.4 2VE 23 4.35 11.0 28.5 11.00 568.4 0.0623 1.78 12.3 23 24 106.88 113.42 Fit= 17.5 1GV 1E 24 8.27 70.0 128.4 0.00 668.4 0.0028 0.36 4.0 24 25 113.42 117.69 Fit= 58.4 1B06 1GV 1T UOFPHONX 06/23/99 0:52am Sheet of Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Detail Actual Total Elev Fric Fric Press Press Pipe Diam Len Len Head Flow Loss Loss Vel Nodes @ Beg @ End No. (inch) (Ft) (Ft) (Ft) (Gpm)(Psi/Ft)(Psi)(Fps) Beg End (Psi) (Psi) 25 8.27 0.0 0.0 0.00 768.4 0.0036 0.00 4.6 25 26 117.69 117.69 ,9 PATRIOT E PROTECTION 2004-A 48th AVENUE CT E. TACOMA, WA 98424 FAX (206) 922-6150 TEL (206) 926-2290 HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME TIS 744 -rt ADDRESS 7 100 R9(2:1" 1 De. ►.)T Way' fl) Ic-u-./ L -P . WA '6 I &,e, CONTRACT NO. t%- 4-61 15 DATE - 2-6)- BY', yrs- LlS1EG k •[ SYSTEM DESIGNATION: HAZARD DESCRIPTION: nr{-t c. -6:=v-t)- i \, .. Pte_ -tom � ,, cvee � [PER NFPA 13 (1991) SECTION A-1.4.7] HAZARD CLASS PER NFPA 13 : ov-P t 1-,AR'f c--9 1 [LIGHT, ORDINARY GP I, ORDINARY GP II, EXTRA, STORAGE] SPECIFIC RULING: ,-r,ew o - ts-1,e.- 1L 54-1.6' e)(7 -0k b-') rift 1,46,1> ('(;-i x L -O - �Gc.r, t 4 w5 RULING MADE BY: IJ OF -T--L4 vul!..c, DENSITY: ,1 GPM OVER THE MOST HYDRAULICALLY REMOTE I Soo SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: INSIDE HOSE GPM OUTSIDE HOSE GPM IN -RACK SPRINKLER DEMAND 1,/,\ GPM SYSTEM TYPE: G -!C ID [TREE, LOOP, GRID] TOTAL NUMBER OF SPRINKLERS ON SYSTEM "C" FACTOR USED: OVERHEAD 12-v UNDERGROUND MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: 16,4 >, (C; SQUARE FEET SPRINKLER MANUFACTURER: PE.t.-tP-43L4_ MODEL: G XL -o Ecoµ ORIFICE SIZE: K -FACTOR: 11. 1.4- TEMP: \6 S ° F WATER SUPPLY: ELEVATION OF TEST: STATIC 15S PSI DATE OF TEST: RESIDUAL I05 PSI DATA PROVIDED BY: DATA- FR+A T��j-r FLOW 1,6P/ GPM LOCATION OF TEST: BASE OF RISER DEMAND 6,73 76. GPM REQUIRED AT X22,53 PSI (INCLUDING GPM FOR HOSE STREAMS) SUMMARY GPM REQUIRED AT 124 .Og AT CONNECTION TO S t.Tf Loop PSI (INCLUDING GPM FOR TOTAL HOSE STREAMS) 'SHEET OF Sd NI 3E1f1SS2Eid TJK-v,llcd4'1S1608 0. (Z— 4(15 II iI ;'ii I1 �I I ' l 1I( 1 I J l i l 1 '1 f I-1 I•' I I I ' 4 .'..1_.I" 1 1 I I 1 I I I, I i T 1. , I 1 �"'__ , 1 i 1 1, i;I j 1i, It; ; ;;;� �] ; ,;;if 1 1' 1 I 1 1 I. i I I 1 1 l I 1 l 4 yI I i I; , 1 1 1 ' 1 I I : 1 II ; � , 1 : It ������1 I :-.._4 ' T • i I I I .. , I .1 I - --i-T- i;i�l I�' ! II I� I`1 II I �Ii ��i jl i it iii 1I ' I ! 1 1 1 I I MO 1 1 I I 1 1 1 � f l ' I 1 I 1 � I 1 �� I .�_ i I 1 I j' � a 0 I -I : 0 3 li 11 I_f it ;Ii ,I WATER SUPPLY DATA 1 STATIC 15 PSI RESIDUAL t°5 - PSI FLOWING 14_67 t 6,rt" r ^ 1 ill II! I __ ] 1l 1 ! i I 1 'iltf'. 1_ tED AT �2 3PM FOR HOSE !III,,• .II III�II! : SUMMAR EOUIRED A St -re. 711 1 ' ®1� +.y - �t' 11 111 ' 1 •r I I t , I I I 1 1t ---- I 1 •I111111.1 it I • •I.-, I ©111111• I i, , -111 iII • N dl ��� I11 �II 1111 I ( O Sd NI 3E1f1SS2Eid SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 1 THERAPUTIC ASSOCIATES T.I. SPR 122 123 124 131 132 133 134 135 143 144 145 146 151 161 162 152 FLOW TEST RESULTS STATIC RESIDUAL AT 1671.0 GPM PRESSURE AVAILABLE AT 673.8 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL FLOW 48.17 47.20 49.20 46.51 43.81 38.90 38.40 39.94 44.12 42.31 41.43 43.07 46.55 41.28 38.96 23.90 MINIMUM FLOW K -FACTOR 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 14.87 5.62 TOTAL WATER REQUIRED FOR SYSTEM TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 PRESSURE 17.85 17.15 18.62 16.65 14.77 11.64 11.35 12.28 14.98 13.77 13.20 14.28 16.68 13.11 11.68 18.09 155.00 PSI 105.00 PSI 145.68 PSI 673.76 GPM 673.76 GPM 126.08 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.028 PSI MAXIMUM VELOCITY IN PIPES 24.50 FPS SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 2 THERAPUTIC ASSOCIATES T.I. FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 34 134 Q 38.40 62 162 61 62 Q 38.96 Q 38.96 1.049 L 1.00 0.4350 PT 11.35 (134) F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 2.61 PT 13.53 ( 34) 1.380 L 1.00 0.1175 PT 11.68 (162) F=E F 3.00 PE -0.43 DR C120 T 4.00 PF 0.47 1.380 L 16.00 0.1175 PT 11.72 ( 62) F=0 F 0.00 PE 0.00 BN C120 T 16.00 PF 1.88 PT 13.60 ( 61) 61 161 1.380 L 1.00 0.1308 PT 13.11 (161) Q 41.28 F=T F 6.00 PE -0.43 DR C120 T 7.00 PF 0.92 19 61DQ 38.96 1.610 L 42.75 0.2111 PT 13.60 ( 61) Q 80.24 F=T/2E F 16.00 PE 0.00 BN C120 T 58.75 PF 12.40 15 19 3.352 L 2.00 0.0059 PT 26.00 ( 19) Q 80.24 F=0 F 0.00 PE 0.00 NC C120 T 2.00 PF 0.01 PT 26.01 ( 15) 52 152 1.049 L 1.50 0.1810 PT 18.09 (152) Q 23.90 F=T F 5.00 PE -0.65 DR C120 T 6.50 PF 1.18 51 52 1.049 L 8.00 0.1810 PT 18.62 ( 52) Q 23.90 F=0 F 0.00 PE 0.00 BN C120 T 8.00 PF 1.45 PT 20.07 ( 51) 51 151 1.049 L 1.50 0.6212 PT 16.68 (151) Q 46.55 F=T F 5.00 PE -0.65 DR C120 T 6.50 PF 4.04 17 51DQ 23.90 1.380 L 5.00 0.3516 PT 20.07 ( 51) Q 70.46 F=2T F 12.00 PE 0.22 BN C120 T 17.00 PF 5.98 PT 26.27 ( 17) 46 146 1.049 L 1.00 0.5380 PT 14.28 (146) Q 43.07 F=E F 2.00 PE -0.43 DR C120 T 3.00 PF 1.61 45 46 2.067 L 16.00 0.0198 PT 15.46 ( 46) Q 43.07 F=0 F 0.00 PE 0.00 BN C120 T 16.00 PF 0.32 PT 15.78 ( 45) SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 3 THERAPUTIC ASSOCIATES T.I. FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 45 145 Q 41.43 44 144 Q 42.31 43 143 Q 44.12 35 135 34 35 Q 39.94 Q 39.94 1.049 L 1.00 0.5005 PT 13.20 (145) F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.00 PT 15.77 ( 45) 1.049 L 1.00 0.5204 PT 13.77 (144) F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.12 PT 16.46 ( 44) 1.049 L 1.00 0.5624 PT 14.98 (143) F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.37 PT 17.92 ( 43) 1.049 L 1.00 0.4679 PT 12.28 (135) F=E F 2.00 PE -0.43 DR C120 T 3.00 PF 1.40 2.067 L 16.00 0.0172 PT 13.25 ( 35) F=0 F 0.00 PE 0.00 BN C120 T 16.00 PF 0.28 33 34DQ 38.40 2.067 L 6.00 0.0598 PT 13.53 ( 34) Q 78.34 F=0 F 0.00 PE 0.00 BN C120 T 6.00 PF 0.36 PT 13.89 ( 33) 33 133 Q 38.90 1.049 L 1.00 0.4455 PT 11.64 (133) F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 2.67 32 33DQ 78.34 2.067 L 20.00 0.1261 PT 13.88 ( 33) Q 117.24 F=2E F 10.00 PE 0.00 BN C120 T 30.00 PF 3.78 PT 17.66 ( 32) 32 132 1.049 L 1.00 0.5551 PT 14.77 (132) Q 43.81 F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.33 31 32DQ 117.24 2.067 L 10.00 0.2269 PT 17.67 ( 32) Q 161.05 F=0 F 0.00 PE 0.00 BN C120 T 10.00 PF 2.27 PT 19.94 ( 31) 31 131 1.049 L 1.00 0.6201 PT 16.65 (131) Q 46.51 F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.72 SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 4 THERAPUTIC ASSOCIATES T..I. FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 30 31DQ 161.05 2.067 Q 207.56 L 6.75 0.3628 PT 19.94 ( 31) F=T F 10.00 PE 0.00 BN C120 T 16.75 PF 6.08 PT 26.02 ( 30) 24 124 1.049 L 1.00 0.6880 PT 18.62 (124) Q 49.20 F=E F 2.00 PE -0.43 DR C120 T 3.00 PF 2.06 23 24 2.227 L 16.00 0.0176 PT 20.25 ( 24) Q 49.20 F=0 F 0.00 PE 0.00 BN C120 T 16.00 PF 0.28 PT 20.53 ( 23) 23 123 1.049 L 1.00 0.6373 PT 17.15 (123) Q 47.20 F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.82 22 23DQ 49.20 2.227 L 14.00 0.0611 PT 20.54 ( 23) Q 96.40 F=0 F 0.00 PE 0.00 BN C120 T 14.00 PF 0.86 PT 21.40 ( 22) 22 122 1.049 L 1.00 0.6616 PT 17.85 (122) Q 48.17 F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.97 21 22DQ 96.40 2.227 L 16.00 0.1292 PT 21.39 ( 22) Q 144.57 F=0 F 0.00 PE 0.00 BN C120 T 16.00 PF 2.07 15 21 2.227 L 3.75 0.1292 PT 23.46 ( 21) Q 144.57 F=T F 16.00 PE 0.00 BN C120 T 19.75 PF 2.55 PT 26.01 ( 15) 44 45 2.067 L 10.00 0.0688 PT 15.78 ( 45) Q 84.50 F=0 F 0.00 PE 0.00 BN C120 T 10.00 PF 0.69 43 44DQ 42.31 2.067 L 10.00 0.1458 PT 16.47 ( 44) Q 126.81 F=0 F 0.00 PE 0.00 BN C120 T 10.00 PF 1.46 16 43DQ 44.12 2.067 L 22.75 0.2533 PT 17.93 ( 43) Q 170.93 F=T F 10.00 PE 0.00 BN C120 T 32.75 PF 8.30 PT 26.23 ( 16) 2 3 3.352 L 30.00 0.3042 PT 81.80 ( 3) Q 673.76 F=E F 8.00 PE 0.00 NC C120 T 38.00 PF 11.56 PT 93.36 ( 2) SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 5 THERAPUTIC ASSOCIATES T.I. FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 15 30 Q 0.67 3.352 8 15DQ 224.81 2.227 Q 225.48 4 8DQ -89.57 2.227 Q 135.92 3 4 3.352 Q 135.92 5 8 2.227 Q 89.57 16 30 3.352 Q 206.89 17 16DQ -47.38 3.352 Q 159.51 18 17DQ 70.46 3.352 Q 229.97 7 18 2.227 Q 229.97 6 7 3.352 Q 229.97 6 16 Q 218.31 2 227 L 120.00 0.2770 PT 26.22 16) F=T,2E/2E,T F 52.00 PE 0.00 BL C120 T 172.00 PF 47.64 L 16.00 0.1431 PT 73.86 ( 6) F=0 F 0.00 PE 0.00 CM1 C120 T 16.00 PF 2.29 L 10.00 0.0000 PT 26.01 F=0 F 0.00 PE 0.00 CM2 C120 T 10.00 PF 0.00 L 94.00 0.2941 PT 26.01 F=6E/2T F 62.00 PE 0.00 BL C120 T 156.00 PF 45.88 L 60.00 0.1153 PT 71.89 F=T,E F 21.00 PE 0.00 BL C120 T 81.00 PF 9.34 L 10.00 0.0157 PT 81.23 F=T F 26.00 PE 0.00 CM1 C120 T 36.00 PF 0.57 PT 81.80 L 48.00 0.0533 PT 71.89 F=T/T F 32.00 PE 0.00 BL C120 T 80.00 PF 4.26 PT 76.15 30) 15) 8) 4) 3) 8) ( 5) L 6.00 0.0342 PT 26.01 ( 30) F=0 F 0.00 PE 0.00 CM2 C120 T 6.00 PF 0.21 L 2.00 0.0212 PT 26.22 ( 16) F=0 F 0.00 PE 0.00 CM2 C120 T 2.00 PF 0.04 L 14.00 0.0416 PT 26.26 ( 17) F=0 F 0.00 PE 0.00 CM2 C120 T 14.00 PF 0.58 L 120.00 0.3050 PT 26.84 ( 18) F=T/T F 32.00 PE 0.00 BL C120 T 152.00 PF 46.36 L 16.00 0.0416 PT 73.20 ( 7) F=0 F 0.00 PE 0.00 CM1 C120 T 16.00 PF 0.67 PT 73.87 ( 6) ( 5 6DQ 229.97 3.352 Q 448.28 SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 6 THERAPUTIC ASSOCIATES T.I. FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 3 5DQ 89.57 3.352 L 2.00 0.2005 PT 76.15 ( 5) Q 537.84 F=T F 26.00 PE 0.00 CM1 C120 T 28.00 PF 5.61 PT 81.76 ( 3) 1 2 3.`352 L 14.00 0.3042 PT 93.33 ( 2) Q 673.76 F=T,E/E F 42.00 PE 4.33 FR C120 T 56.00 PF 17.04 99 1 4.352 L 12.00 0.0853 PT114.70 ( 1) Q 673.76 F=BV,E F 29.00 PE 4.33 FR C120 T 41.00 PF 3.50 0 99 6.160 L 50.00 0.0118 PT122.53 ( 99)'Psc of Q 673.76 F=T,GV/2E F 68.00 PE 2.16 (zi.SeiC- UN C140 T 118.00 PF 1.39 PRESSURE AVAILABLE AT NODE 0 AT 673.8 GPM MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.028 PSI MAXIMUM VELOCITY IN PIPES 24.50 FPS PT126.08 ( 0) 145.7 PSI to*' VyW1� 7v SM TH,.FIRE SYSTEMS, INC. 1106 54th Avenue East • Tacoma, Washington 98424 (253) 926-1880 • FAX (253) 926-2350 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME HYUNDAI T.I. JOB NO. T1-119 DATE 5/11/99 ADDRESS 7100 FORT DENT WAY BY LORIE COLE TUKWILA, WASHINGTON SYSTEM DESIGNATION: 1 HAZARD DESCRIPTION: OFFICES HAZARD CLASS PER NFPA 13 : ORDINARY HAZARD GROUP 1 SPECIFIC RULING: RULING MADE BY: OF DENSITY: .15 GPM OVER THE MOST HYDRAULICALLY REMOTE 1500 SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: INSIDE HOSE 0 GPM OUTSIDE HOSE 250 GPM CITY WATER MAIN (NODE 0) IN -RACK SPRINKLER DEMAND GPM SYSTEM TYPE: WET TOTAL NUMBER OF SPRINKLERS THIS SYSTEM 29 "C" FACTOR OVERHEAD : 120 "C" FACTOR UNDERGROUND : 140 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: 256 SQUARE FEET SPRINKLER MANUFACTURER: RELIABLE MODEL: G XLO-ECOH TEMPERATURE: 165 ° F K -FACTOR: 11.4 ORIFICE SIZE: .64" WATER SUPPLY: STATIC 155 PSI RESIDUAL 105 PSI FLOW 1671 GPM ELEVATION OF TEST: --- DATE OF TEST: DATA PROVIDED BY: CITY OF TUKWILA PUBLIC WORKS DEPT. LOCATION OF TEST: AT THE SITE BASE OF RISER DEMAND 528.17 GPM REQUIRED AT 48.65 PSI (INCLUDING 0 GPM FOR HOSE STREAMS) SUMMARY 778.17 GPM REQUIRED AT 53.90 PSI AT CONNECTION TO CITY WATER MAIN (INCLUDING 250 GPM FOR TOTAL HOSE STREAMS) Z��4•T4-11=14 0 W Ow o " Z nl VIVA 14.1:1il1WiTALI W 10 W 0 ✓ r F to tt$1 zO 8 i • N 8 ISd NI 31IflSS31Id st O 0 0) co O a O N O SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 FLOW TEST RESULTS Water Supply STATIC 155.00 PSI RESIDUAL 105.00 PSI C 1671.00 GPM CITY PRESSURE AVAILABLE. AT 778.2 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR 351 50.16 38.40 352 48.41 38.40 353 25.40 18.90 354 25.37 14.87 355 26.01 14.87 356 25.20 14.87 357 24.93 14.87 358 24.73 18.11 359 23.46 18.75 360 23.45 14.87 361 49.26 38.40 362 42.10 38.40 363 21.83 14.87 364 38.40 38.40 365 39.87 38.40 366 39.60 38.40 11.40 11.40 5.62 5.62 5.62 5.62 5.62 5.62 5.62 5.62 11.40 11.40 5.62 11.40 11.40 11.40 TOTAL WATER REQUIRED FOR SYSTEM OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 251 TO 351 PRESSURE 1;.36 18.03 20.43 20.37 21.42 20.11 19.68 19.36 17.43 17.41 18.67 13.64 15.08 11.35 12.23 12.07 142.84 PSI 528.17 GPM 250.00 GPM 778.17 GPM 53.88 PSI 0.00 PSI 18.62 FPS 05-11-1999 PAGE 1 SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 2 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 264 364 1.049 L 2.75 C=120 PT 11.35 (364) O 38.40 F=T,E F 7.00 PE -0.32 DR T 9.75 0.4350 PF 4.24 PT 15.27 (264) 266 366 265 266 O 39.60 Q 39.60 1.049 L 0.75 C=120 PT 12.07 (366) F=T F 5.00 PE -0.32 DR T 5.75 0.4605 PF 2.65 2.203 L 16.00 C=120 PT 14.40 (266) F=0 F 0.00 PE 0.00 BN T 16.00 0.0124 PF 0.20 PT 14.60 (265) 265 365 1.049 L 0.75 C=120 PT 12.23 (365) Q 39.87 F=T F 5.00 PE -0.32 DR T 5.75 0.4663 PF 2.68 264 26500 39.60 2.203 L 15.00 C=120 PT 14.59 (265) Q 79.47 F=0 F 0.00 PE 0.00 BN T 15.00 0.0450 PF 0.68 263 26400 38.40 2.203 L 4.00 C=120 PT 15.27 (264) Q 117.87 F=0 F 0.00 PE 0.00 BN T 4.00 0.0934 PF 0.37 PT 15.64 (263) 263 363 1.049 L 0.75 C=120 PT 15.08 (363) Q 21.83 F=T F 5.00 PE -0.32 DR T 5.75 0.1530 PF 0.88 262 26300 117.87 2.203 L 5.00 C=120 PT 15.64 (263) Q 139.69 F=0 F 0.00 PE 0.00 BN T 5.00 0.1279 PF 0.64 PT 16.28 (262) 262 362 1.049 L 0.75 C=120 PT 13.64 (362) O 42.10 F=T F 5.00 PE -0.32 DR T 5.75 0.5156 PF 2.96 25 262D0 139.69 2.203 L 15.00 C=120 PT 16.28 (262) Q 181.79 F=T F 14.00 PE 0.00 BN • T. 29.00 0.2081 PF 6.03 PT 22.31 ( 25) 261 361 Q 49.26 1.049 L 0.75 C=120 PT 18.67 (361) F=T F 5.00 PE -0.32 DR T 5.75 0.6896 PF 3.97 SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 3 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 260 360 1.049. L 7.25 0=120 PT 17.41 (360) Q 23.45 F=T,2E F 9.00 PE -0.32 DR T 16.25 0.1746 PF 2.84 259 260 2.203 L 6.25 C=120 PT 19.93 (260) Q 23.45 F=0 F 0.00 PE 0.00 BN T 6.25 0.0047 PF 0.03 PT 19.96 (259) 259 359 1.049 L 7.25 C=120 PT 17.43 (359) Q 23.46 F=T,2E F 9.00 PE -0.32 DR T 16.25 0.1749 PF 2.84 258 259DQ 23.45 2.203 L 11.75 C=120 PT 19.95 (259) Q 46.91 F=0 F 0.00 PE 0.00 BN T 11.75 0.0170 PF 0.20 PT 20.15 (258) 258 358 1.049 L 0.75 C=120 PT 19.36 (358) Q 24.73 F=T F 5.00 PE -0.32 DR T 5.75 0.1927 PF 1.11 257 258DQ 46.91 2.203 L 9.00 C=120 PT 20.15 (258) Q 71.64 F=0 F 0.00 PE 0.00 BN T 9.00 0.0372 PF 0.33 PT 20.48 (257) 257 357 1.049 L 0.75 C=120 PT 19.68 (357) Q 24.93 F=T F 5.00 PE -0.32 DR T 5.75 0.1957 PF 1.13 256 2570Q 71.64 2.203 L 7.00 0=120 PT 20.49 (257) Q 96.57 F=0 F 0.00 PE 0.00 BN T 7.00 0.0646 PF 0.45 PT 20.94 (256) 256 356 1.049 L 0.75 C=120 PT 20.11 (356) Q 25.20 F=T F 5.00 PE -0.32 DR T 5.75 0.1996 PF 1.15 250 256D0 96.57 2.203 L 1.00 C=120 PT 20.94 (256) Q 121.78 F=TF .14.00 PE 0.00 BN T 15.00 0.0992 PF 1.49 PT 22.43 (250) SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 4 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 255 355 1.049 , L 0.75 C=120 PT 21.42 (355) Q 26.01 F=T F 5.00 PE -0.32 DR T 5.75 0.2116 PF 1.22 250 255 2.203 L 5.00 C=120 PT 22.32 (255) Q 26.01 F=T F 14.00 PE 0.00 BN T 19.00 0.0057 PF 0.11 PT 22.43 (250) 254 354 1.049 L 0.75 C=120 PT 20.37 (354) O 25.37 F=T F 5.00 PE -0.32 DR T 5.75 0.2020 PF 1.16 253 254 2.203 L 11.00 C=120 PT 21.21 (254) Q 25.37 F=0 F 0.00 PE 0.00 BN T 11.00 0.0054 PF 0.06 PT 21.27 (253) 253 353 1.049 L 0.75 C=120 PT 20.43 (353) O 25.40 F=T F 5.00 PE -0.32 DR T 5.75 0.2025 PF 1.16 252 253D0 25.37 2.203 L 14.00 C=120 PT 21.27 (253) Q 50.77 F=0 F - 0.00 PE 0.00 BN T 14.00 0.0197 PF 0.28 PT 21.55 (252) 252 352 1.049 L 0.75 C=120 PT 18.03 (352) O 48.41 F=T F 5.00 PE -0.32 DR T 5.75 0.6676 PF 3.84 24 252DQ 50.77 2.203 L 9.00 C=120 PT 21.55 (252) Q 99.17 F=T F 14.00 PE 0.00 BN T 23.00 0.0678 PF 1.56 PT 23.11 ( 24) 251 351 1.049 L 0.75 C=120 PT 19.36 (351) O 50.16 F=T F 5.00 PE -0.32 DR T 5.75 0.7131 PF 4.10 PT 23.14 (251) 35 261 2 203 • :L 121.50 C=120 PT 22.31 (261) Q 48.04 F=0/2E,T F 28.00 PE 0.00 BL3 T 149.50 0.0177 PF 2.65 PT 24.96 ( 35) SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 5 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 25 261 2.203 L 1.00 C=120 PT 22.31 (261) O 1.22 • F=T.2E F 28.00 PE 0.00 BL3 T 29.00 0.0000 PF 0.00 • 250 25D0 142.41 3.314 L 6.00 C=120 PT 22.31 ( 25) O 143.63 F=0 F 0.00 PE 0.00 CM4 T 6.00 0.0184 PF 0.11 24 250D0 147.79 3.314 L 10.00 C=120 PT 22.42 (250) O 291.42 F=0 F 0.00 PE 0.00 CM4 T 10.00 0.0682 PF 0.68 251 24D0 -278.23 2.203 L 5.00 C=120 PT 23.10 ( 24) O 13.19 F=T F 14.00 PE 0.00 BL2 T 19.00 0.0016 PF 0.03 43 251DQ 50.16 2.203 L 42.67 C=120 PT 23.13 (251) O 63.35 F=0 F 0.00 PE 0.00 6L2 T 42.67 0.0296 PF 1.26 PT 24.39 ( 43) 26 25 3.314 L 16.00 C=120 PT 22.31 ( 25) Q 39.38 F=0 F 0.00 PE 0.00 CM4 T 16.00 0.0017 PF 0.03 36 26 2.203 L 134.50 C=120 PT 22.34 ( 26) Q 39.38 F=T,5E/2E,T F 77.00 PE 0.00 BL3 T 211.50 0.0123 PF 2.60 35 36 3.314 L 16.00 C=120 PT 24.94 ( 36) O 39.38 F=0 F 0.00 PE 0.00 CM5 T 16.00 0.0017 PF 0.03 34 35D0 48.04 3.314 L 16.00 C=120 PT 24.97 ( 35) O 87.41 F=0 F 0.00 PE 0.00 CM5 T 16.00 0.0074 PF 0.12 29 34D0 25.73 3.314 L 13.50 C=120 PT 25.09 ( 34) Q 113.15 F=0 F 0.00 PE 0.00 CM5 T 13.50 0.0119 PF 0.16 PT 25.25 ( 29) 19 24 3.314 1 :13.50 C=120 PT 23.10 ( 24) Q 377.41 F=0 F 0.00 PE 0.00 CM4 T 13.50 0.1101 PF 1.49 PT 24.59 ( 19) SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 6 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 44 43 2.203 L 33.33 C=120 PT 24.40 ( 43) O 38.20 F=0 F 0.00 PE 0.00 8L2 T 33.33 0.0116 PF 0.39 42 44D0 -25.73 2.203 L 16.00 C=120 PT 24.79 ( 44) Q 12.47 F=T F 14.00 PE 0.00 BL5 T 30.00 0.0015 PF 0.05 PT 24.84 ( 42) 41 43 O 25.15 34 44 Q 25.73 2.203 L 16.00 C=120 PT 24.40 ( 43) F=T F 14.00 PE 0.00 BL4 T 30.00 0.0054 PF 0.16 PT 24.56 ( 41) 2.203 L 39.00 C=120 PT 24.79 ( 44) F=0/T F 14.00 PE 0.00 BL2 T 53.00 0.0056 PF 0.30 PT 25.09 ( 34) 42 41 2.203 L 46.42 C=120 PT 24.56 ( 41) Q 17.81 F=T,5E F 49.00 PE 0.00 BL1 T 95.42 0.0028 PF 0.27 33 42D0 12.47 2.203 Q 30.28 BL1 L 39.00 C=120 PT 24.83 ( 42) F=0/T F 14.00 PE 0.00 T 53.00 0.0076 PF 0.40 PT 25.23 ( 33) 23 41 2.203 L 47.67 C=120 PT 24.56 ( 41) Q - 7.34 F=T F 14.00 PE 0.00 BL1 T 61.67 0.0005 PF 0.03 PT 24.59 ( 23) 23 19 3.314 L 2.50 C=120 PT 24.59 ( 19) Q 32.11 F=0 F 0.00 PE 0.00 CM4 T 2.50 0.0012 PF 0.00 22 23DQ 7.34 3.314 L 16.00 C=120 PT 24.59 ( 23) Q 39.44 F=0 F 0.00 PE 0.00 CM4 T 16.00 0.0017 PF 0.03 32 22DQ -20.96 2 203 L 122.17 C=120 PT 24.62 ( 22) Q 18.48 F=T,3E/3E,T 'F '•'70.00 PE 0.00 BL T 192.17 0.0030 PF 0.58 PT 25.20 ( 32) SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 7 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From'To GPM IN Devices Ft PSI/Ft PSI 21 22 3.314 L 16.00 C=120 PT 24.62 ( 22) Q 20.96 F=0 F 0.00 PE 0.00 CM4 T 16.00 0.0005 PF 0.01 31 21 2.203 L 120.00 C=120 PT 24.63 ( 21) Q 20.96 F=T/T F 28.00 PE 0.00 BL T 148.00 0.0038 PF 0.56 32 31 3.314 L 16.00 C= Q 20.96 C=120 PT X�,.19 ( 31) 5 F=0 F 0.00 PE 0.00 CM5 T 16.00 0.0005 PF 0.01 33 32130 18.48 3.314 L 16.00 C=120 PT 25.20 ( 32) Q 39.44 F=0 F 0.00 PE 0.00 CM5 T 16.00 0.0017 PF 0.03 29 33D0 30.28 3.314 L 2.50 C=120 PT 25.23 ( 33) Q 69.72 F=0 F 0.00 1 PE 0.00 CM5 T 2.50 0.0043 PF 0.01 28 29D0 113.15 3.314 L 37.00 C=120 `:PT 25.24 ( 29) Q 182.87 F=2E/T F 45.00 'PE 0.00 CM3 T 82.00 0.0288 PF 2.36 27 28 3.314 L 11.54 C=120 PT 27.60 ( 28) 0 182.87 F=E F 11.00 PE 5.00 CM3 T 22.54 0.0288 PF, 0.65 16 27 3.314 L 12.75 C=120 PT 33.25 ( 27) Q 182.87 F=T F 23.00 PE 0.00 CM3 T 35.75 0.0288 PF 1.03 6 16 3.314 L 191.50 C=120 PT 34.28 ( 16) 0 182.87 F=T,4E F 67.00 PE 0.00 CM1 T 258.50 0.0288 PF 7.44 5 6 3.314 L 12.04 C=120 PT 41.72 ( 6) Q 182.87 F=T F 23.00 PE 0.00 CM T 35.04 0.0288 PF 1.01 PT 42.73 ( 5) 18 19 3.314 L Q 345.30 F=2E/T F CM2 T 37.00 C=120 PT 24.59 ( 19) 45.,00 PE 0.00 82:00 0.0934 PF 7.66 SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 8 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 17 18 3.314 L 11.54 C=120 PT 32.25 ( 18) Q 345.30 F=E F 11.00 PE 5.00 CM2 T 22.54 0.0934 PF 2.11 . 5 17 3.314 L 2.29 C=120 PT 39.36 ( 17) Q 345.30 F=T,E F 34.00 PE 0.00 CM2 T 36.29 0.0934 PF 3.39 4 5D0 182.87 4.310 L 10.63 C=120 PT 42.75 ( 5) Q 528.17 F=BV F 12.00 PE 4.61 FR T 22.63 0.0570 PF 1.29 2 4 8.265 L 35.00 C=140 PT 48.65 ( 4) Q 528.17 F=E F 19.00 PE 0.00 UN2 T 54.00 0.0018 PF 0.10 1 2 8.265 L 0.01 C=120 PT 48.75 ( 2) Q 528.17 F=0 F 0.00 PE 5.00 UN1 T 0.01 0.0024 PF 0.00 COMMENT: 11.54 FT SLOPE ADDED TO REPRESENT 5 PSI LOSS THRU COMMENT: 8 INCH FEBCO 850 - DCVA 0 1 8.265 L 25.00 C=140 PT 53.75 ( 1) Q 528.17 F=T,GV F 58.00 PE 0.00 UN T 83.00 0.0018 PF 0.15 COMMENT: 250 GPM ADDED AT NODE 0 FOR OUTSIDE HOSE ALLOWANCE. PT 53.90 ( 0) PO Box 3932 Seattle WA 98124-3932 206-234-5700 Fire Com NW, LLC Battery Calculation Work Sheet Project: Dr Timmerman TI — Fort Dent III Office Building 7100 — Fort Dent Way — Suite 270 Tukwila WA 98188 This project consists of a tenant improvement project for an existing fire alarm system. The building is fully sprinklered. This scope of work will include installing 10 new signaling devices to the existing fire alarm system. This battery calculation work sheet is for the existing power supply, 1 existing device and 10 new devices. Qty Part # and description Supervised Current mA Alarm Current mA 1 5495 Power supply 75 175 2 NS Horn strobe 0 268 9 RSS Strobe 0 369 Subtotal 75 812 Total battery power hours x24 x.083 Subtotal 1800 67 Safety factor - 10% + 180 + 7 Total 1980 ma 74 ma Total Current Required 2054 ma or 2.1 amps Battery size used: 2ea - 12volt, 7amp PAD NOV - 4 2005 Tukwila Fire �Zd/1F2 .ris- FIRE SYSTEM ACCESSORY Firepower 5495 fad Distributed Power Module In an emergency, you need maximum power The Firepower 5495 Distributed Power Module by Silent Knight is the most - powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, Wheelock and Faraday — what you need to drive power-hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need Firepower 5495. Call Silent Knight today for more information at 1-800-446-6444. Firepower 5495 Distributed Power Module The firepower 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features • UL Listed for 6 amps of notification power • Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems • Dip switches allow for easy reconfiguration • 24 VDC filtered output voltage • Four power -limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B • Additional continuous auxiliary output • 3 amps per output circuit • 2 inputs; 2 Class B or 2 Class A • Ground fault detector/indicator • • • • • • • Independent trouble relay AC Toss delay option shuts off power to non-essential high -current accessories like magnetic door holders Built-in synchronization for appliances from System Sensor®,Gentex®, Wheelock and Faraday Stand alone operation. Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized, UL Listed notification devices UL 864 & 1481 listed • CSFM approved • ANSI Cadence pattem output capability built-in Connection to Local Fire Control Firepower 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end -of -line resistor is also connected across two terminals on the Firepower 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7k) end -of -line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one Firepower 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. Firepower 5495 Distributed Power Module )1` b SILENT KNIGHT FIRE SYSTEM AeCESSORY Firepower 5495 Distributed Power Module 4JA) Supervision Firepower 5495 supervises a variety of functions including: • Low AC power. • Low battery condition. • Earth ground fault. • Auxiliary output power limit condition. • EOL supervision trouble or power limited condition at an output. When a trouble condition occurs, Firepower 5495 creates a trouble condition on the host control signal circuits to which it is connected. Firepower 5495 still maintains the ability to be activated by the host control. In addition, the 5495 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. Electrical Specification AC Input: 120 VAC at 2 amps Output: 24 VDC at 6 amps Current: Standby Alarm Auxiliary power circuit: Notification circuits: Output configuration: Amps per output circuit: Notification circuit output: No. of inputs Input configuration: 75 mA 175 mA 1 4 2 Class A (Style Z) 4 Class B (Style Y) (1 Class A & 2 Class B) 3.0 (6.0 amps total) 20.4 to 27.3 VDC @ 3.0 amps each, 4.7 kg/ EOL resistor required on each Class B circuit 2 2 Class B or 2 Class A Input voltage range: 9 - 32 VDC Battery charging capacity: 33.0 AH Ambient Temp.: 32° to 120° F 0° to 49° C Mechanical Dimensions: 12.25" W x 16" H x 3"D(30.88cmW x 40.64 cm H x 7.62 D cm) Indicator Lights AC power on : Green Battery trouble: Yellow Ground fault: Yellow Aux Trouble: Yellow Output troubles (1-4): Yellow Approvals: UL: 864 & 1481 NFPA: 72 CSFM Model 5495 Block Diagram Signal Circuit Output Signal Circuit Output Signal 1 input Signal 2 input (Optional) 120 VAC Local Fire Control Distributed Power Module 5495 Trouble Output (Alternative to notification circuit trouble.) Signal 1 Signal 2 Signal 3 Signal 4 Aux. Power SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350395, Rev. 04/02 Copyright 0 2002 Silent Knight • phP UVI SLY] rTr" FIRE ALARM SYSTi EYS L �f� O Helping People Take Actions' SL 1Dr® , ❑ '� j ( ( 71, A Family of Multi -Candela Appliances`" Description The Series NS Hom Strobe Appliances will satisfy virtually all requirements for indoor, wall mount applications. The Series NH Horn and the horn portion of the Series NS include a selectable continuous horn tone or temporal pattern (Code 3) with selectable dBA settings of 90 or 95 dBA. Strobe options include 1575cd or Wheelock's patented Multi -Candela strobe with field selectable candela settings of 15/30/75/110cd. These versatile Horn Strobe Appliances may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules or Wheelock's PS-12/24-8MP Power Supply with patented Sync Protocol. Additionally, the audible may be silenced while maintaining strobe activation. All models of the Series NS and NH are designed for maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest requirements of NFPA 72/ANSI 117.1/UFC and UL Standards 1971 and 464 as well as meeting ADA requirements concerning photosensitive epilepsy. Wheelock's patented 2 -Wire Series NS Hom Strobes and Series NH Horns offer more features with low current draw. Copyright 2003 Wheelock Inc. All rights reserved. SERIES NS SINGLE & MULTI -CANDELA HORN STROBE APPLIANCES SERIES NH HORNS Series NH 1 Series NS X11 . Multi -Candela Indicator (bottom of Strobe Lens) Features • Approvals include: UL Standard 1971, UL Standard 464, New York City (MEA), California State Fire Marshal (CSFM) and Factory Mutual (FM) Pending: Chicago (BFP) • ADA/NFPA/UFC/ANSI compliant • Complies with OSHA 29, Part 1910.165 • Field Selectable Candela Settings 15/30/75/110cd (24 VDC Multi -Candela models) or 1575cd in 12 or 24 VDC • Selectable Continuous Horn or Temporal (Code 3) • 2 Selectable dBA settings of 90 and 95 dBA in both tones • Patented Universal Mounting Plate • 12 and 24 VDC models with llL"Regulated Voltage" using filtered DC or unfiltered VRMS input voltage • Wall Mount • NH horn is selectable 12 or 24 VDC in 1 unit • Synchronize with Wheelock SM, DSM Sync Module or Wheelock PS-12/24-8MP Power Supply with built-in sync protocol • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range'. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0'C to 49°C) and maximum humidity of 93% (t 2%). • Series NH homs are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL Standard 1971 Model Input Voltage VDC Regulated Voltage Range VDCIFWR Strobe Candela (CD) NS-24MCW 24 16.0 - 33.0 15/30/75/110 NS -241575W 24 16.0 - 33.0 15 (75 on Axis) NS -121575W 12 8.0 -17.5 15 (75 on Axis) Table 2: dBA Ratings for Series NS/NH Hom Description Volume Reverberant dBA @ 10it per UL 464 Anechoic dBA @ 10 ft 12VDC 24VDC 12VDC 24VDC Continuous Horn High 83 87 89 95 Low 76 81 84 90 Code 3 Hom High 79 82 89 95 Low 72 76 84 90 Table 3: Average RMS Current Series NS/NH 24 VDC Audible Wall Mount Audible Strobe Models NH -12/24 NS 241675W NS-24MCW @24VDC 16/76cd 1Scd 30cd 75cd 110cd High (95) dBA 16VDC 0.019 0.120 0.077 0.113 0.195 0.268 24VDC 0.028 0.094 0.065 0.087 0.134 0.174 33VDC 0.039 0.102 0.069 0.082 0.117 0.134 Low (90) dBA 16VDC 0.017 0.116 0.070 0.106 0.188 0.261 24VDC 0.022 0.093 0.052 0.072 0.126 0.168 33VDC 0.027 0.078 0.045 0.060 0.097 0.114 Series NS/NH 12VDC Audible Wall Mount NH -12/24 Aud/Strobe @12V NS -121576W High (89) dBA 8VDC 0.013 0.341 12VDC 0.019 0.251 17.5VDC 0.024 0.216 Low (84) dBA 8VDC 0.010 0.324 12VDC 0.015 0265 17.5VDC 0.018 0.188 *Average RMS Current is per UL average RMS method and Average Mean Current is per UL average mean method. NH models use average mean current. For rated In Rush and Peak current across the UL listed voltage range for both filtered DC and unfiltered VRMS (FWR), see installation instructions. SYNC MODULES/POWER SUPPLY Model Number Order Code Input Voltage (VDC) *Average Mean Current (I24VDC Mounting Options SM -1224.8 6369 24 .028 W DSM -12248 6374 24 .035 W PS-1224.8MP 3046 120/220 VAC (a 50/60 Hz; 5.0 amps maz NOTES: SM Sync Module is rated for 3.0 amperes 24 VDC; DSM Sync Module is rated for 3.0 amperes per circuit The maximum number of interconnected DSM Modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. Refer to Data Sheet S9000 or Installation InstructionsPS-12/24-8MP Power Supply. A WARNING: CONTACT WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS (P83983) SERIES NS-24MCW, (P84234) SERIES NS -12 AND 24 VDC SINGLE CANDELA MODELS, (P83600) SERIES NH AND "GENERAL INFORMATION" SHEET(P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILLAFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCES OR FUSES. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • THESE APPUANCESARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF. • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITYSHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams# NS/NH APPUANCE FROM + + TO NEXT PRECEDING - y APPLIANCE APPLIANCE, SM/DSM, ■1 OR EOLR PS-12124-8MP OR FACP SIGNAL NS AND NH APPLIANCES SYNCHRONIZED WITH DSM MODULE DUAL CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE ari6YNCRICOULE NS AND NH APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILENCE FEATURE F A SM Strobl NAC Circuit + STROBE O1 STROBE I1 O +Auditd. EOLR Audib b -Audlbl. NAC Circuit NOTE: NS/NH must be set on Code 3 horn tone to achieve synchronized temporal (Code 3) tone. Refer to installation instruction (P83983, P83600 respectively). *For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the PS-12/24-8MP Power Supply refer to Installation Instructions P84333. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). ARCHITECTS AND ENGINEERS SPECIFICATIONS The audible/visual notification appliances shall be Wheelock Series NS Hom Strobe appliances and Series NH Hom appli- ances or approved equals. The Series NS appliances shall meet and be listed for UL Standard 1971(Emergency Devices for the Hearing -Impaired for Indoor Fire Protection Service). The Series NH Hom shall be UL Listed under Standard 464 (Fire Protective Signaling). The hom strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of two (2) field selectable settings for dBA levels (90 and 95 dBA) and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series NS shall be of low current design. Where wall mount, Multi -Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15/30/75/110 candela. The selector switch for selecting the candela setting shall be tamper resistant The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-12/24-8MP Power Supply with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (Le., contacts remain closed), the strobes shall revert to a non -synchronized flash -rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series NS Hom Strobes and NH hom shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single -gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. PECIFICATION & ORDERING INFORMATION Model Order Code Strobe Candela Non- Sync Sync w/ SM, DSM or PS-12124-8MP 24 VDC 12 VDC 2 WIRE Mounting OptIo Agency Approvals UL MEA CSFM FM BFP NS-24MCW-FR 9404 15130/75/110 X X X - X B,D,E,F,GH,J,N,O,R,X X X X X X NS-24MCW-RN 9405 15/30/75/110 X X X - X B,D,E,FAH,J,N,O,R,X X X X X X NS -241575W -FR 7806 15 (75 on Axis) X X X - X B,D,E,F,GH,J,N,O,R,X X X X X X NS -121575W -FR 7816 15 (75 on Axis) X X - X X B,D,E,F,c H,J,N,O,R,X X X X X X NH -12/24-R 7449 24V X X X X X B,D,E,F,GH,J,N,O,R,X X X X X X Note: Models are ava.lable in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA National Sales Office 800-631-2148 Canada 800-397-5777 E -Mail: I nfo@wheelockinc.com http://www.wheelockinc.corn "emu Member Distributed By: 273 Branchport Avenue • Long Branch, NJ 07740 • TEL: 732-222-6880 • FAX: 732-222-2588 S2100 10/03 E CLQ r 1 � � Helping People Take Actions" DESCRIPTION Wheelock's patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or Wheelock's Patented MCW multi -candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi - candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules or the PS-12/24-8CP and PS-1224-8MP Power Supplies with Wheelock's Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA72. Wheelock's Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim fortheAppliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi -Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with Wheelock's SBL2 surface backbox. For Weatherproof Series RSS See Datatsheet S9004 Copyright 2004 Wheelock, Inc. All rights reserved. SERIES RSS & RSSP SINGLE & MULTI -CANDELA STROBES & STROBE PLATES ars ,,.r. Series RSS Series RSSP RSS Round 71,ler;:, /117011111111 Multi-Candella Indicator (bottom of Strobe Lens) Features • Approvals include: UL Standard 1971, NewYork City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information • ADA/NFPA/UFC/ANSI compliant. Meets OSHA29 Part 1910.165 • Wall mount Multi -Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. Single Candela models are available in 1575cd • Ceiling mount Multi -Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL"Regulated Voltage" using filtered (DC) or unfiltered VRMS input voltage • Synchronize using Wheelock's sync modules or power supplies with built-in sync protocol • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All wamings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 species a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series RSS & RSSP Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 93% (t 2%). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* Product RSSIRSSP - Wall Mount RSS - Ceiling Mount RSSIRSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24 vdc 0.060 0.041 0.063 0.109 0.140 0.195 0270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSSIRSSP RSSIRSSP * RMS current ratings are per UL average RMS method. UL max current 24VDC Wall Mount rating is the maximum RMS current within the listed voltage range (16-33v Models 121575W for 24v units). For strobes the UL max current is usually at the minimum is usually at 12 vdc 0.152 listed voltage (16v for 24v units). For audibies the max current the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, UL max* 0.255 see installation instructions. Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Muttitone Appliances AMT, MT Homs AH, NH, HS Motor Bells MB-G6/G10 Speakers ET -1010/1080, E70, ET70 Chimes CH70 A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIORTO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH ANDAMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams # SERIES RSSIRSSP APPLIANCE FROM PRECEDING ± APPUANCE, SYNC MODULE, POWER SUPPLY OR FACP + TO NEXT APPLIANCE OR EOLR SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT STROBE NAC CIRCUIT OUT DSM TROBE NAC CIRCUIT RETURN STROBE/PLATE ASSE MBLY AUDIBLE& VISIBLEAPPLIANCEOPERATE IN UNISON FROM PRECEDING - APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP TO NEXT + APPLIANCE OR EOLR ALVISIE STROBE/PLATE ASSE M B LY AUDIBLE & VISIBLEAPPLIANCE OPERATE INDEPENDENTLY STROBE APPLIANCE SERIES RSSIRSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM SERIES RSS/RSSPAPPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES F A c P Strobe NAC Cir. DSM #1 DI z m - I DSM #2 1 sy+nc rozar Sicairmit DSM #3 DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES RSS/RSSP A PPUANC ES SYNCHRONIZED WITH PS-12/24-8CP or PS-12/24-8MP F A C P OUTPUTS 1-4 4 -CLASS .a. OR 2 -CLASS S.d.s PS-12/2441AP EOLR • For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for PS-12/24-8MP. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (N FPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi -Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be speed when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-12/24-8CP and PS-12/24-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non -synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single -gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi -Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. s and Ordering Information Model Order Code Wal Mount Ceiling Mount Non -or Sync Sync wf SI /,DSM PS -12/2 8CPIMP Strobe Candela 24 VDC 12 VDC # Model Color RED # Model Color WHITE Mounting Options"' uare or Round Agcy Approvals UL MEA CSFM FM BFP RSS24MCW-FR 9400 X - X X 15/30/751110 X - X - B,D,E,F,GH,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - X X 15/30/75/110 X - - X B,D,E,F,GH,J,N,O,RX Square X X X X X RSS-241575W-FR 7471 X - X X 15 (75 on /Ws) X - X - B,D,E,F,GH,J,N,O,RX Square X X X X X RSS-241575W-FW 7788 X - X X 15 (75 onAkds) X - - X B,D,E,F,GH,J,N,O,RX Square X X X X X RSS-121575W-FR 7476 X - X X 15 (75 on Abs) - X X - B,D,E,F,GH,J,N,O,RX Square X X X X X RSS-121575W-FW 7468 X - X X 15 (75 on Ards) - X - X B,D,E,F,GH,J,N,O,RX Square X X X X X RSS-24MCC-FW 3158 - X X X 15130/7595 X - - X B,D,EF,GH,J,N,O,RX Square X X X X * RSS-24MCCER 3157 - X X X 15130//595 X - X - B,D,E,F,GH,J,N,O,R)k Square X X X X * RSS-24MCCR-FW 3160 - X X X 15/30/7595 X - - X B,D,E,F,GH,J,N,O,RX Round X X X X * RSS-24MCCR-FR 3159 - X X X 15/30/7595 X - X - B,D,E,F,GH,J,N,O,RX Rood X X X X * RSS24MCCHIW 3461 - X X X 115/177 X - - X B,D,E,F,GH,J,N,O,RX Square X X X * * RSS24MCCHR-FW 3463 - X X X 115/177 X - - X B,D,E,F,GH,J,N,O.RX Round X X X * * RSS-24MCWHFR 3465 X X X 135/185 X X B,D,E,F,GH,J,N.O,RX Square X X X * * RSSWP-2475W-FR" 9013 X - X X 180 a 77°F 75at31°F X - X - B.D,E,F,GH,J,N,O,RX Square X X X X * RSSwP-2475W.fW* 3034 X - X X 180 @ 77°FX 75@31'F - - X B,D,E,F,GH,J,N,O,RX Square X X X X * RSSP-121575W-FR 7798 X - X X 15 (75 on Aids) - X X - 0,EZ Square X X X X X RSSP-24MCWFR 9402 X - X X 15/30/75/110 X - X - D,EZ Square X X X X X RSSP-241575WFR 7793 X - X X 15 (75 on Aids) - - X - D,EZ Square X X X X X RSSP-24MCWH-FR 9482 X X X 135/185 X X B,D,E,F,GH,J,N,O,f,k Square X X X * * 1 Models are avalable in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3 YEAR WARRANTY Made in USA NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 E-mail: Infocwheelockinc.com http://www.wheelockinc.com IrCZNI Member *PENDING Distributed By: WHEELOCK, INC. • 273 BRANCHPORTAVE • LONG BRANCH, N.J. 07740.732-222.6880 • FAX: 732-222-2588 80410 05/05 021. DR.'S LAV. UA LO t 1 1 2 a 4 k SJPPL" C BiNET AREA OF WORK IIIA'IIR,1 rm. .-� TO EXISTING PS o-9 TANTS 0 • DIE4. H �rTh OP N4 oP N,. r OP #2 b GP NI 1 A9A H 7 PT.'S LAV. 5 it PHOTO CCN4LLTATION STAFF t-OUNGE WASHER/ DRYER STACKED Hd3J/NJd VNC,.: 1 1 1 FT— - F— PS FIRST FLOOR FIRE ALARM RISER DIAGRAM SCALE: NONE 04 FIRE ALARM PLAN K7 SCALE: 1/8"-1"-0" EQUIPMENT LEGEND ADEM DESCRIP110N PART NUNIBER DESCIBPSON BASKS= BASKB ®Q 2 NS HORN STROBE 4 SQUARE X 1-7/8' DEEP ID 9 RSS STROBE 4 SQUARE X 1-7/8" DEEP WIRE LEGEND TWE DESCRIP110N A 18 AWG, 2 CONDUCTOR 'FPLP' JACKETED CABLEI 8 14 AWG, 2 CONDUCTOR 'FPLP' JACKETED CABLEI C 18 AWG, 4 CONDUCTOR 'FPLP' JACKETED CABLEI r GENERAL NOTES: 1. ALL WORK 1S TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. 2. WIRING METHOD 1S TO 8E OPEN CABLING EXCEPT WHERE R 18 EXPOSED AND BELOW SEVEN FEET • THEN IT 18 TO BE IN CONDUIT. 3. ALL JUNCTION BOXES, COVERS, AND BACK BOXES ARE TO BE PAINTED RED. 4. ALL INDOOR HORNS, STROBES, HORN STROBES, AND MINI HORN STROBES ARE TO BE MOUNTED 80" ABOVE THE FLOOR OR W BELOW THE CEILING, WHICHEVER 18 LOWER. 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE OF FLAME AND HOT GASES. FIRE COM NW LLD PO Box 3832 3.attle WA 981244932 205.2344700 DATE: 10/25/05 PROJECT HAW: DRAWN: CEA DR. TIMMERMAN T.I. CHECKED: JD 7100 Fort Dent Way - Suite 270 APPROVED 8Y JD Tukwila, WA 98188 SHEET ME: SCALE: 1/8"-1-0" FIRE ALARM PLAN NO. DATE REVISION BY JOB NUMBER: 05-174 FA -1 of 1 A comp!et_d, = , T!'kifv;la Fire De0a; ...;~;._ Certificate musc be esen.pd to ;he InF--..:ector prior to :. con nee . ent Acc ? o= m Ice any moire L:i on c\,,steirs. iinnt�aRe-iinsp Re -inspection Fee and ler minatof f of the (.e..:tino. !UKWILA FIRE DEPAr<t-ivttldl Please call: 575-4407 ?-nd give this job No..0 and exact address for shut. ouwn or restoration approval. ACCEPTED Witr'out Comments As Noted In Red Per The Attached Letter iThese plans have been reviewed by The Tukwila Fire Prevention Buress_i 'ipr conformance with current city i standards. Acca::'F cc:s subject to errors and omissions which o., not wuihonze violations of adopted u stand: -.rd Inn c-"': r.c=:•s. The responsibility for the adeo- ~' c` -; 11 i tr, tiotslly with the designer. Addit;o . (.--.;- ,..„n 6 revisions zu these drawings after i Ithis d 4 \P.! \ ! ,ic ,"‘s acceptance and will require a 4 resubm._«i' c .t. -ed ara'rrings for subsequent approval. i Final acceptance is subject to field test and inspection by r, The Tukwila Fire PreventionBureau. ' 1. Date: /// O By: L/ -/- c-70 g Symbol Legend SYMBOL DESCRIPTION MANUFACTURER PART NUMBER MODEL QUANTITY USER TEXT UL FM NAG „ Ex 6 AMP NAC POWER SUPPLY W/SYNC SILENT KNIGHT SK 5495 5495 1 EX Listed 5495 POWER EXTENDER PANEL MAIN MOTHER BOARD P PULL, DUAL ACTION SILENT KNIGHT PS -DA PS -DA 2 STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD S8012 N/A DI VGD HORN/STROBE, EXCEDER 24V, M -C, RED, WALL. COOPER WHEELOCK HSR HSR 14 EX S2852 Approved E. STROBE, EXCEDER 24V, M -C, RED, WALL COOPER WHEELOCK STR STR 1 EX S2852 Approved "0' STROBE, EXCEDER 24V, M -C, RED, CEILING COOPER WHEELOCK STRC STRC 7 1 S2652 Approved )'.:( HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING COOPER WHEELOCK HSRC HSRC 2 Total Peripheral Stby S2652 Approved EOL 4.7K IZ ar EOL 4.7K SILENT KNIGHT EOL -4.7 EOL -4.7 1 19.2264V (0.0195V) 9 • 15CD EOL 4.7K f2 \ / 15CD / 75CD Battery Calculations for Panel: P1: EX Part No:SK 5495 - 6 AMP NAC POWER SUPPLY W/SYNC Job number: 817-0652 Job name: TABOR Address 1: 7100 FORT DENT WAY, SUITE 100 Address 2: TUKWILA, WA 98188 Phone; 253-833-1248 Fax: Designing engineer: MATT CARLMAN Authority having jurisdiction: CITY OF TUKWILA Part No. Qty. Description Standby Total Standby Alarm Total Alarm FAX: SK 5495 Panel Equipment WA ST LICENSE: FIRESWI055LW 20.2V SK 5495 MB 1 5495 POWER EXTENDER PANEL MAIN MOTHER BOARD 75.0000mA 75.0000mA 205.0000mA 205.0000mA 2 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD Total Panel Stby 75.0000mA Total Panel Alarm 205.0000mA 3 STRC Peripheral Devices 96'-0 61.0000mA 19.4414V (0.3543V) STRC 7 STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 61.0000mA 427.0000mA HSRC 2 HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 148.0000mA 296.0000mA EOL -4.7 1 EOL 4.7K (Notification) 0.0000mA 0.0000mA 0.0000mA 0.0000mA 7 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 75CD Total Peripheral Stby 0,0000mA Total PeriphAlarm 723.0000mA 8 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 26'-0 61.0000mA 19.2264V (0.0195V) 9 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD Total Standby Amps 75.0000mA Total Alarm Amps 928.0000mA Standby time: 24 Hrs 1.8Ah Alarm time: 5 Min 0.077Ah Battery requirement: 1.877Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 2.253Ah 75CD / \ / 5b fib o Gos so Circuit Calculations Panel: P1 Card: 00 Circuit:SIG4 Circuit Name: SIG4 Circuit Type: Notification . Terminal Voltage: 20.2V:DC Amperage: 2.0000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop FAX: SK 5495 Panel WA ST LICENSE: FIRESWI055LW 20.2V 1 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 16'-0 61.0000mA 20.129V (0.071V) 2 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 87-0 61.0000mA 19.7957V (0.3333V) 3 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 1500 96'-0 61.0000mA 19.4414V (0.3543V) 4 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 13'-0 61.0(300mA 19,3983V (0.0431V) 5 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 16-0 61.0000mA 19.3542V (0.0441V) 6 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 75CD 28'-0 148.0000mA 19.2823V (0.0719V) 7 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 75CD 22'-0 148.0000mA 19.2459V (0.0365V) 8 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 26'-0 61.0000mA 19.2264V (0.0195V) 9 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 11'-0 61.0000mA 19.2223V (0.0041V) EOL -4.7 EOL 4.7K 2'-0 0.0000mA 19.2223V (OV) 311'-0 723.0000mA Total Current: 723.0000mA (Total VOrop Percent:4.84%) Total Voltage Drop : 0.9777V 14/2 15CD 15CD 15CD 15CD 15CD / \ / \ / \ / ,, \ / 0 / \ / \ / \ / \ / v. it 1 : 1)% ; vt cos vs cos co- cos 5495 120V 20 AMP Area 0 sr,. x N >"t"a't.4 'e.r. U,i fi� Y.,::"r".,;5:Y4 :.x „f ;r ) Sret>oi.. ,. ,,., v e. , -"au,•v e i. ).. t.. i. a• ,'r.,.3r a :.Q dri •l4,t , 5 N •,>x, �.' , t}, ,,,c`xi"n� , cd , tfi'J,ti'� �. Isw4,�.`n.x`c" x�^, ,a. iS"UtiA" xfi,nS & 9 to ';• .. .. ,.. <.:� .; ,.. o,.., � ,., x xs, a t�xur c � ,..1,• � ".tr•.�kY�. "%t... 1. :"f, r.'a1.4X ,'c>7' „Xr..•�'n, 1'«,p t• -r Sr .4 ..r �..Sa+v. S.'x. ��+Ui(kr.S.{e7„V,�)td�'Yi~ki „d"d?4,`4 �§'`� Y�. h {`) ,.. .,... ,.. ,o.,. ,,., ,y .• . Y,. �c e x.;.xsu.:a r netc•5 � ��r,... ! ., f:' 1• ,} ), tai, �,. ,{..o<.Sf, r!1,:v`l°/a?{dl .,, YsO, �, x t . „ ., . ,.,,, ,., 5, ' r h ,..F.,. a :.. ft, t, l'.:.Zr~.,>,. n �Yti�c, s;.dt{fi7'�ss,`esYfiSx?y�.x '<z3 lis^.lt}'tS,.%)„atM 4a5;¢,,,=,;.i�S.;N.A.�',. r rv" ♦ rr�uRx�mxn��rx ♦ �,'�r����s ♦ ���r ♦ r��>n��{,�a� ♦ ��>rr�,<���s�sa,�� ♦ i5�x�,��� • a�,,,m.�{:ta�,��; ♦ �ztrr�:r„3,rc�.,�x�,;a ♦ �,,w�.�:nitr{a?��� ♦ a,z��a$�.,„rx,cr� ♦ �,,.�a.^w ��a., ♦ � )rw.<„s„�ca�� ♦ �mr,..,I �t �„� ♦ �� 1 CAUSE SMOKE I HEAT bETECTOSS IuttiNUAEUUCC'STATION _.__-._-.......... -SYSTEM RESIT SidNAL SICENC ... I' N RTAiL1Rg............_ FIRE ALARSI TROU$LE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS_,-_._ -TAMI3Eti SY41TGTl SS-- `WATERFLOW SWITCH FIRE ALARM SYSTEM OPERATIONAL. MATRIX ___._.......SND__..._......_-......Th0U8t.t jSUPERtII50RY MISCELLANEOUS m © A 0 re 6 A 0 01 0 re Pr WIRING DIAGRAM ' Without Comments ® As Noted in Red El Per The Attached Letter ' .ese plans have been reviewed by The Tukwila Fire - vention Bureau for conformance with current City ndards. Acceptance is subject to errors and fissions which do not authorize violiations of adopted :,ndards and ordinances. rhe responsibility for the .equacy of design rests totally with the designer. dditions, deletions or r evisio, is to these drawings after this -date will void this r:,:+:eptance and will require a resubmittal of revis_°ci (1, -Livings for subsequent approval. Final acceptance: is .abject co tleid test and Inspection b\; The Tukwila Fire Preventio: i Bureau. r ')ate: I 0 / I J C By: Permit i''WFUrt 1i.i'.�ir Iq-r-i�� To sc heduie riOr1S Cali 206-575-4407 GENERAL NOTES 1 SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.F.PA., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE INSTALLING NEW FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER SITE CONTACT: TABOR DESIGN/SUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY, SUITE 100 206 FRONTAGE ROAD NORTH, STE TUKWILA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735-0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE: FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735-0113 X NICET LEVEL II 146053 WORK AREA A 1412 FPLP B 1612 FPLP EX EXISTING LOCATION (SWAP FOR NEW DEVICE) WP WEATHER PROOF N NEW DEVICE R RELOCATE • STROBE COVERAGE AREA SHALL BE DEFINED AS 10 FT. CLG, HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd =20x20' 30 cd = 20120' 75 cd = 20'x2e 30 cd = 30130' 75 cd = 30X30' 95 cd = 30'x30' 75 cd = 40X40' 95 cd =40)(40' 110 cd = 40X40' 95cd=50X50' 110cd=50X50' 115cd=501(50' Sciulhein Gsiil Accounting Tax $ervices Skill .<.tiiisv; l Opii,'t (fing%s. 'roup cattle, WA: • aple Gest Alianrrients ". <:-z`: i�arkview Apartment amid ic;r1 ,ra„ .i /ti:,;' u?ton Sea'tii 'rack Merldiari Valley Lob Kwan; Endadon(1 VICINITY MAP SCALE: N.T.S. PAID 1 0 1- 1- M = M_ CO Hca _Z o 1111 Q IDC Z ril t9 corink% 4C Ct Ilki H 0 CS a as ac) elcCCNI CL Fax: (253) 735-0113 N M M co I0 WA ECL# FIRESWI 055LW WA CL# FIRE W 1- 0 cra z O ISSUED_FOR_REVIEW 0 z EW DEVICE COUNT g� 0 0 0 0 0 0 0 0 W N z lz W 1- �r W W 1-- D W W -J W 0 0 a MS -7 SERIES a 0 a W 2 SYSTEM SENSOR SYSTEM SENSOR CEIUNG HORN STROBE OUTDOOR WALL HORN STROBE SYSTEM SENSOR SYSTEM SENSOR J 0 0 I J WSJ ,S (5 0 LL J JsJ LL -J -J m O x w ce PULL STATION SMOKE SENSORS HEAT SENSORS m z 0 z TABOR FIRE ALARM PLAN w z r ct w6 J oOmJ z �� 8 it) t0 O co g. 11 w w ( coo ^( CO C•1 CCJ m i CV H �M Q 1!i U LLIZ o 0 Iii 0 O a. LLco it 1 o; W Ii = J far \ / SIG4.2 /0\ 15CD OFFICE \o/ SIG4.3 / \ 15CD OFFICE \�/ SIG4.4 / \ 15CD OFFICE \ / SIG4.5 /0\ 15CD • ❑ 0 SIG4.6 75CD HUDDLE \�/ SIG4.1 15CD \ SIG4.7 75CD EX 15CD 0 SIG4 EOL 4.7K i2 / SIG4.9 \ 75CD \ / SIG4•8 u• 15CD 7tt�aWSeH�"S,: OFFICE OFFICE 0 GRAND MEETING ROOM ( TABOR iF 1111111 f MIN y{' ' 8' CLE: 118'=1'-0" 12' 20' TRAINING ROOM SUITE 100 FIRE ALARM PLAN GENERAL Ni TES! SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE INSTALLING NEW FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER SITE CONTACT: TABOR DESIGNISUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY, SUITE 100 206 FRONTAGE ROAD NORTH, STE i TUKWILA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735.0113 WA ST LICENSE: FIRESW I140B1 WA ST LICENSE: FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735-0113 X NICET LEVEL II 146053 WORK AREA Drawing reviewed by: Rodrigo G. Quinteros NICET Certification No. 125166 Fire Alarm Systems - Level III Certification Expires: October 1, 2019 A B EX WP N R 1412 FPLP 16/2 FPLP EXISTING LOCATION (SWAP FOR NEW DEVICE) WEATHER PROOF NEW DEVICE RELOCATE • STROBE COVERAGE AREA SHALL BE DEFINED AS 10 FT. CLG. HT. 20 FT. CLO. HT. 30 FT. CLG. HT. 15 cd = 207.:20' 30 cd .205(20' 75 cd = 20'x20' 30 cd = 30'40' 75 cd = 305(30' 95 cd = 305(30' 75cd=40Y40' 95cd=405(40' 110cd=405(40' 95cd=50560' 110 ed=505(50' 115cd=505(50' outh€�fn Gn Accounting& Tax Services, S1dIL Maple Crest Ap rtrilents. ilomed:oo(i.itl l,fior <<:atY tr . cY71 eddi;rn Wiley Lab condo VICINITY MAP: SCALE: N.T.S. ' w F - co 0 206 FRONTAGE ROAD C7f 0 z 5s c ctc WA ECL# FIRESWI 055LW co w 0 0 0 0 N d act 0 0 tY 0 0 0 0 0 0 a N W F LIJ 1--' LLI ~ F 0 W 1-- tW— W J 0 0 OC 6. y MS•7 SERIES 1 SYSTEM SENSOR SYSTEM SENSOR CEILING HORN STROBE OUTDOOR WALL HORN STROBE SYSTEM SENSOR SYSTEM SENSOR c3 1 J 0 0 J WSJ GAMEWELL FCI J W 0t— N 0 Z N fi 3 3 PULL STATION SMOKE SENSORS 0 HEAT SENSORS e rn 0 1 TABOR FIRE ALARM PLAN W z W co 0 a' J otimLLL1 8 c'' v, a W 1�—\ V/ s co I— Z 1 w Q< I— z eto`S 0LL m C V 1—�I— ON-SITE CONTACT: BILLY SHADRIN 206-2989 Q 1 O LCL 1-- W w N - FILE:Tabor Fire Alarm Plans DATE:09/19/19 TIME:15:13:40 - Fire Alarm Symbol Legend SYMBOL DESCRIPTION PART NUMBER _ MODEL QUANTITY _USER TEXT UL______ _FM__ MISCELLANEOUS I Panel Equipment CAUSE 0', (e., 0;0 5 �d �4i Qd �� F� v� v5 �4�P`� Q\Y- \)�+ QS', ., N. ��°gQ40J�QOJ� 4 Q aJQ� p� pcid i 20.4V REMARKS 5495B ;07( HORN/STROBE, 24V, M -C, RED AS-24MCW-FR AS-24MCW-FR 7 EX E5946, S5391 Approved \ / Total Panel Stby 75.0000mA Total Panel Alarm 205.0000mA 3 HSRC Peripheral Devices /o 30CD STROBE, EXCEDER 24V, M -C, RED, CEILING STRC STRC 2 2 S2652 Approved /o 15CD STROBE, EXCEDER 24V, M -C, RED, CEILING STRC STRC 4 STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) S2652 Approved 8 95CD HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING HSRC HSRC 2 0.0000mA S2652 Approved 352.0000mA 6 AMP NAC POWER SUPPLY W/SYNCH 5495 5495 1 0.0000mA Listed 766.0000mA NAC . ® EOL 4.7K S1 EOL 4.7K EOL -4.7 EOL -4.7 1 - - - ._..__....... ...._....__.... Battery Calculations for Panel: P2 Part No:5495 - 6 AMP NAC POWER SUPPLY W/SYNCH Job number: 817-0319 Job name: KEURIG GREEN MOUNTAIN Address 1: 7100 FORNT DENT WAY Address 2: TUKWILA, WA 98188 Phone: (253)833-1248 Fax: (253)735-0113 Designing engineer: MATT CARLMAN Authority having jurisdiction: CITY OF TUKWILA Part No. Qty. Description Standby Total Standby Alarm Total Alarm MISCELLANEOUS I Panel Equipment CAUSE 0', (e., 0;0 5 �d �4i Qd �� F� v� v5 �4�P`� Q\Y- \)�+ QS', ., N. ��°gQ40J�QOJ� 4 Q aJQ� p� pcid i 20.4V REMARKS 5495B 1 5495 POWER EXTENDER PANEL MAIN MOTHER BOARD 75.0000mA 75.0000mA 205.0000mA 205.0000mA 2 0 0 Total Panel Stby 75.0000mA Total Panel Alarm 205.0000mA 3 HSRC Peripheral Devices 38'-0 176.0000mA 19.3624V (0.1447V) STRC 2 STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 85.0000mA 170.0000mA STRC 4 STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 61.0000mA 244.0000mA HSRC 2 HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 176.0000mA 352.0000mA 7 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD Total Peripheral Stby 0.0000mA Total Periph Alarm 766.0000mA 8 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 95CD 10'-0 176.0000mA _SYSTEM RESET - - ..._.... - SIGNAL SILENCE -- .... - --... AC POWER FAILURE FIRE ALARM TROUBLE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS - - - ._..__....... ...._....__.... Total Standby Amps 75.0000mA Total Alarm Amps 971.0000mA Standby time: 24 Hrs 1.8Ah Alarm time: 5 Min 0.081Ah Battery requirement: 1.881Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 2.257Ah ID Without CorrmLerlts As Nater. `�.:.. a Per The Attached Letter These plans have been revieweo to The Tukwila Fire Prevention Bureau for conformance r•:Mich current City standards. Acceptance is subjer7 .vrors and omissions which (.1;,+ 1.10t -al,! r;Orizt ,1;:,i,31:ions of adopted standards anr+ r;:.rifti:0,tr-.°s . The r sxc.nsOility for the adequacy of design totally with the designer. Additions, deletirP r,.,vlsions to these drawings after this date %Mil v-Dlo o.,t3 ;, cceptafce and will rec(uire a resubmittatrnwings for sunsequent approval. Final acceptance iM. F,obiec t to field test and inspection by The Tukwila Fire Prtevent:lon Bureau. Date: /- I I J TUKWILA FIRE DEPARTMENT `e•y�r' - .1 7.1 ":'''''r-575-4407 and - - 'or shut - ort approval. . 95CD D • 15CD 0 . r FIRE ALARM SYSTEM OPERATIONAL MATRIX Device Part No Appliance Desc Distance Current ALARM TROUBLE SUPERVISORY MISCELLANEOUS I Panel CAUSE 0', (e., 0;0 5 �d �4i Qd �� F� v� v5 �4�P`� Q\Y- \)�+ QS', ., N. ��°gQ40J�QOJ� 4 Q aJQ� p� pcid i 20.4V REMARKS 1 STRC SMOKE! HEAT DETECTORS 165'-0 0 0 0 2 0 0 27'-0 85.0000mA 19.5071V (0.1169V) 3 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 95CD 38'-0 176.0000mA 19.3624V (0.1447V) 4 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 30CD 18'-0 85.0000mA 19.3134V (0.0491V) MANUAL PULL STATION STRC 0 0 0 19.1877V 0 0 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 2V-0 61.0000mA 19.1493V (0.0384V) 7 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 11'-0 61.0000mA 19.1333V (0.016V) 8 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 95CD 10'-0 176.0000mA _SYSTEM RESET - - ..._.... - SIGNAL SILENCE -- .... - --... AC POWER FAILURE FIRE ALARM TROUBLE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS - - - ._..__....... ...._....__.... - - ..__... - __.._.... 0 0 - O 0 - _ -- - 0.._ - - - - -- O..O ---- TAMPER SWITCHES 0 0 0 `WATERFLOW SWITCH 0 0 0 0 O 1 15CD 0 . Circuit Calculations Panel: P2 Card: 01 Circuit:SIG2 CircuitName: SIG2 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 2.0000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop FAX: 5495 Panel WA ST LICENSE FIRESWI055LW 20.4V 1 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 165'-0 61.0000mA 19.624V (0.776V) 2 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 30CD 27'-0 85.0000mA 19.5071V (0.1169V) 3 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 95CD 38'-0 176.0000mA 19.3624V (0.1447V) 4 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 30CD 18'-0 85.0000mA 19.3134V (0.0491V) 5 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 57'-0 61.0000mA 19.1877V (0.1256V) 6 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 2V-0 61.0000mA 19.1493V (0.0384V) 7 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 11'-0 61.0000mA 19.1333V (0.016V) 8 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 95CD 10'-0 176.0000mA 19.1225V (0.0108V) 347'-0 766.0000mA Total Current: 766.0000mA (Total VDrop Percent:6.26%) Total Voltage Drop : 1.2775V 15CD 0 30CD 0 95CD D 30CD 0 20 AMP DEDICATED CIRCUIT . . . WIRE DIAGRAM . . . . . Area 0 . GENERAL NOTES I SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST ' U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE INSTALLING NEW FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. FIRE ALARM SYSTEM INFORMATION INSTALLER/SUPPLIER SITE CONTACT: KEURIG GREEN MOUNTAIN DESIGN/SUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C TUKWILA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735-0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735.0113 X FOR FIRE DEPARTMENT USE ONLY APPROVED Bryan Hilfiker NICET III 99709 DNO.ly LOnMby&y,nF llsx Bryan Hilfiker DM:2010A11406.39.000. A B EX WP N R 1412 FPLP 1612 FPLP EXISTING LOCATION (SWAP FOR NEW DEVICE) WEATHER PROOF NEW DEVICE RELOCATE • STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 20'x20' 30 cd = 20'x20' 75 cd = 20'x20' 30 cd = 30'x30' 75 cd = 3D'x30' 95 cd = 30'x30' 75 cd = 404x40' 95 cd = 40'x40' 110 cd =40'x40' 95 cd = 50'x50' 110 cd = 50'x50' 115 cd = 50'x50' WORK AREA aiiufacturers ONinera VICINITY MAP SCALE: N.T.S. PAID' Ail 24 2017 TUKWILA FRF CC. (§ �/ D Fax: (253) 735.0113 WA ECL# FIRESWI 055LW O. 0 m N N 0 z 5 ISSUED_FOR_REVIEW 0 z NEW DEVICE COUNT J 0 z x rn w x w w 1- w 1- 0 w tY w 1- w 1- w 1- x J w 0 a CO MS -7 SERIES w J SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR GAMEWELL FCI GAMEWELL FCI GAMEWELL FCI w w CEILING HORN STROBE OUTDOOR WALL HORN STROBE LL HORN STROBE WALL STROBE PULL STATION SMOKE SENSORS HEAT SENSORS z s 2 • s UUP e KEURIG GREEN MOUNTAIN FIRE ALARM PLAN 0) tti• 0o ON-SITE CONTACT: BILLY SHADRIN 206-361-2989 LCL 1- o w ILLS w w 0 (1) 1-- w w (/) �- FILE:K9urig Fire Alarm Plan.cad DATE:01/23/17 TIME:14:55:12 — RECEPTION CONFERENCE BREAK/COPY ROOM CLOSET OPEN OFFICE STORAGE STORAGE EOL 4.71( O \o \ 30CD 15CD \O / \ MEETING OFFICE OFFICE OFFICE OFFICE MEETING PTN / MUL. PTN / MUL. PTN/MUL. KEURIG GREEN MOUNTAIN 11111 1111 — —.� Sp CA2' LE: 4'118''=18 '0" 12' 20' PTN./ MUL. PTN./ MUL. PTN / MUL. FIRE ALARM PLAN PHONE ' FIRE ALARM SYSTEM OPERATIONAL MATRIX DESIGN/SUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C TUKWILA, WA 98188 ALARM TROUBLE SUPERVISORY MISCELLANEOUS 1 CAUSE a(> a0 JCr cy J ,,(4 A,. ,s1 SOF Ov- Jp �. Pc, �a�F,< �\.P�pP �� �P' 4 �� Q`y Qy4 HiQ, �S �# q< .�Q .� P P P P 0 0 0 C O �t�Q�py1��$`ti g FQ��O�Si`' PGC�`��AN- �Q�0�2O�Q2' co co \f JQ� WA ST LICENSE. FIRESWI055LW REMARKS SMOKE IHEAT DETECTORS 0 0 0 0 0 MANUAL PULL STATION 0 0 0 0 0 SYSTEM RESET 0 SIGNAL SILENCE 0 0 AC POWER FAILURE 0 0 0 FIRE ALARM TROUBLE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS 0 0 0 TAMPER SWITCHES ._._..._......__..._._... 0 0 0 0 ...........__.....-- 0 --- — — ® O. o ---- -- — — — ._--._ `WATERFLOW SWITCH KEURIG GREEN MOUNTAIN 111111 M — ., pp � t SCALEi4118"=180" 20' GENERAL NOTES I SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISKI! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE INSTALLING NEW FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER SITE CONTACT: KEURIG GREEN MOUNTAIN DESIGN/SUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C TUKWILA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833.1248 FAX: FAX: (253) 735.0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE. FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735.0113 X FOR FIRE DEPARTMENT USE ONLY APPROVEb Bryan Hilfiker NICET III 99709 Bryan Hilfiker A B EX WP N R 1412 FPLP 1612 FPLP EXISTING LOCATION (SWAP FOR NEW DEVICE) WEATHER PROOF NEW DEVICE RELOCATE STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 210x20' 30 cd = 2(0x20' 75 cd = 20'x20' 30 cd = 30'x30' 75 cd = 30'x30' 95 cd = 3(0x30' 75 cd = 40'x40' 95 cd = 40'x40' 110 cd = 4(0x40' 95 cd = 500x50' 110 cd = 50 xSO' 115 cd = 50'X50' WORK AREA DIWWb.4nedbyBryan mnm Ok an. Bryan HBBkn. o.i.e Sy. Bem. Wnt IewSWk. eane Of erna II.BryanlieUeSypnmWe.twm .•US Dale 2017.012406,I4.12-0aw nufacturL,r;' Miami VICINITY MAP SCALE: N.T.S. U W 1-- �a RI 0 01 in 0 z z a 0 „le ce z<1...(9co o ti ag: N a. u.u. U Fax: (253) 735-0113 OD c.1 eh CO LK) CS/ WA ECL# FIRES WA CL# FIRESWI 140B1 0 m co z 0 rn ISSUED_ FOR REVIEW z NEW DEVICE COUNT 0 z c z T. w F - x w F- s 1- w F - x 111 0 I- g or � w x w J W 0 5 0 a. a. 0) LL x 5 SYSTEM SENSOR W CEILING HORN STROBE OUTDOOR WALL HORN STROBEI SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR 5 5 W W J J J J W 2 GAMEWELL FCI GAMEWELL FCI WALL HORN STROBE W 0) cr rn J J PULL STATION SMOKE SENSORS HEAT SENSORS co 0 x 5 z 2 -J W EY LL z z 0 2 W LL 0 0 W CONTRACT WITH: z C7 ,- W W < ON-SITE CONTACT: BILLY SHADRIN 206-361-2989 tai :tri 0 r• CO O 0 CD 0 11 Q LL W J V 1-- W +,n 14011 . U W CZ Fire Alarm Symbol Legend GENERAL NOTES 1 SCOPE OF WORK h ,.. c..).,...... c,,, u) DESCRIPTION PART NUMBER MODEL QUANTITY USER TEXT UL FM SYMBOL I;O,< HORN/STROBE, EXCEDER 24V, M -C, RED, WALL HSR HSR 1 R S2652 Approved 1. SYSTEM. WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT ezr 0, re tx = 0) ,ii -4 HORN/STROBE, EXCEDER 24V, M -C, WHITE CEILING HSWC HSWC 1 30CD 82652 Approved APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! Q 0 - Nw STROBE, EXCEDER 24V, M -C, WHITE, CEILING STW STC W 1 • 15CD S2652 Approved 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY ' IQ°epi z 1- c4C co VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING Q N o0G ,�'va I :x+ , il °^fl re^ $,,"'" ' �� w t Withal 1t, f,�irnrnenits TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN gA /y q5 C 4,5� �y _kt° THE SAME RACEWAY. ,.1' � �,iILA FIRE 1.�I PARTHH+�,9'r G 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST ,. �,., , this Fire Permit No. ILL, N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE ,. , .. W ILI -oar CITY STANDARDS. o ®C N IQ. � '•e �' M to e!.. co LIC As I�uter� I.1 Pod 3 3 I ■ Per The Alt, cl �t_�.. _atter W i 1d exact address + 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY < do�n�1cc � >;4 ''° r �� h _se plans have been reviewed l-r�� The Tukwila Fire L',-",ention Bureau for conformance with current City AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT - OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. = 00 --ndards. Acceptance is subject rc�' errors and ,,fissions which do not authorize violations of adopted ;:,ndards and ordinances. The responsibility for the 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION 00 MWC i>A'guacy of design rests totally with the designer, ',c+ditions, deletions orrevisions to these drawings after ,This date will void this acceptance and will require a fesubmittai of revised drawings for subsequent approval. APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. DATE c g cA Final acceptance isvenct to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: i , LI -.1q By: i v''' . 3 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE RELOCATING ONE FIRE ALARM NOTIFICATION n W DEVICES FOR TENANT IMPROVEMENT. 0 Z 10. FIRE SYSTEM WEST WILL BE INSTALLING ONE NEW FIRE ALARM NOTIFICATION DEVICE FOR TENANT IMPROVEMENT. 11. OFFICES 1 & 2 ARE ISSUED_FOR_R LESS THAN 120 SQFT. ci E,. BV �:aii % �/�°`� E I a x31 ..�// E r'�e S j TOTAL P , , . ,�`� _,✓,, � F /l f✓ •.� ... /^,h aw'�wvanu (�. .E„z„"� �,: ,&?.•. 'E / ►"Y.b �" 'T j'. ,// qs� • ''✓'' ;� E E -'.j F�^ 5, s f EE I , O O O O O O C Cf E'.+WbPaMYdA4b'a.'A4M' �� .s' I .d .a . t .,�� il/i�I �-., .,.... ".,.... .... ...._.6 �. q�yn m's,:,.,ws?� , 9A.iWa'FaGnWltap✓p'.. ��.. _ _ tlpppY�lN'd� VAIVAIIPPAIPAIVA �,{. licerArdir:Arir FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER x, WHITE WHITE WHITE WHITE WHITE WHITE WHITE i ' ZCT h_ SITE CONTACT: a D ESIGNISUPPLIER: I 77 KEURIG EXPANSION FIRE SYSTEMS WEST,INC. to 11 2'-0v ii ,• � it 7100 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C ” A w P w ”' TUKWILA, WA 98168 PACIFIC, WASHINGTON 98047, m a. ii' a- 11) r� 2 Ir .� �� PHONE: PHONE: (253) 833.1248 0 1... ) FAX: FAX: (253) 735.0113 �"� ,�' E Q,; ,--►" �"'7 �F WA 5T LICENSE: FIRESWI140B1 WA ST LICENSE FIRESWI055LW e : r © - IFIrdirettlirAler111,1 _—DESIGNER - '--'- -- z z„: ' --OFF►CE-1- of W W W W JJJJmmm / a4� 30CD m;tlrnto� OFFICE 2 •• MATT C ARLMAN ,,_ wwww/ I. � ,_J(�FIRE SYSTEMS WEST, INC ” I y rtn Ii �, A'IP �. ,,,� JIP ,, 206 FRONTAGE ROAD NORTH, STE C � � � �, � � � � _E, 1� b _." .... / PACIFIC, WASHINGTON 98047 :OUNT X PHONE (253) 833-1248 Fire Alarm Designer w m (253) 735.0113 Bryan Hilfiker �I\�,I _ I _FAX: IINICET 1 III 99�m 7,g:1.0= _►- o � ix :0) / , / / r' '-•-'..� ~,� ,... 15CD �AlOP �( Br.Vansl9rrMbyBryanHIlllker�.A�E�IrynHIHlNer o.Flre Sritemt West. � Inc,Ou-SpoWneofflce, r anal. ,mUS TYPE CEILING HORN STI OUTDOOR WALL F WALL HORN STRO WALL STROBE PULL STATION [SMOKE SENSORS HEAT SENSORS �I DatC.1017.1736114745-08'00' 2017 225-08'00 H i If i ke r LIJ OFFICE 3 A . /' cn -...,___-........., I Al A11011 AO Affil ,„ I Rix m g0 Fr: O \! EXPANSION AREA NICET LEVEL 11 146053 . W KEURIG EXPANSION FIRE ALARM PLANA 1412FPLP B 1612 FPLP EX EXISTING LOCATION CT WITH: C. 3ALLINGER WAY N LE, WA 98155 WAP FOR NEW M � � "�: I " Ill ;;,; �.,�,. .. " � _:3 4 ' DEVICE) WP WEATHER PROOF 41/8 =18' 12 20 N' NEW DEVICE R RELOCATE SCALE: -STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 20'x20' 30 cd = 20'x20' 75 cd = 20'x20' 30 cd = 30X30' 75 cd = 30X30' 95 cd = 30'x30' 75 cd = 40'x40' 95 cd = 40'x40' 110 cd = 40540' 50'11 05 eel a , 110 eel a!MA' Y 115Mafi(Yy511' CO CP KEURIG EXPANSION FIRE ALARM PLAN CONTRACT NAME: CONTRA KEURIG EXPANSION DP IN 7100 FORT DENT WAY 19936 TUKWILA, WA 98168 SEATTI CONTACT: VASILY SHADRIN 206-361-2 urig Fire Alarm Plan.cad DATE:12126/17TIME:11:03:15 WORK AREA ; .. • r.. I^•: �zii J Fort DattitPtay:. 1-. �.y�yy yy ..-_... ..:... .. .... y ...,.. ':,"-;y'%t MariufaclUrers Mineral.:. vl' . Homewood ,,::.:' Homewood fpra ,:; ... .. ...... ,T'J -. ,-.. .. ^.. .:.'r, :,='.,....... `ii' `.... .....: `"' ... HMori 5eati e:Tocdm#s:, .... .. .. ........ .. r. ......:....: i: may, ...... . r FIRE ALARM SYSTEM OPERATIONAL MATRIX I1S'[i ithWo(ks Pd.eidiaa Volley Lab r ° ;rhea! Y ALARM TROUBLE SUPERVISORY MISCELLANEOUS I Croix r r O 4 O O VL 54i ♦ O �J Q •V Q J PC♦P� 49 5 F �, JQ5 ',}tt.BtAte3C�Ado. 4 ::.: ..:.....':: .. �. , h c air...Airport sd ,,•- _ ;:4:.. ; TUk>iid'Fafttil GQ J PG� J YP�i4J O & NO' ..k.‘...k0 PP V. Q J0 QEQ.0 .0 OOOQQv G4iG� CAUSE (P'P' - . c, Q- - GP J O O y REMARK Fin Cettfr: a SUBWAY ,RePtrtturts .. E ... 817-0434 12126/2017 Ca SMOKE tHEAT DETECTORS O 0 0 0 0 n MANUAL PULL STATION 0 0 0 0 0 O SYSTEM RESET 0 OA Q SIGNAL SILENCE ®0 AC POWER FAILURE CINIT/ ::: Y iP INITIATION QR SIGNALING CIRCUITS9'!011 TAMPER SWITCHES 0 0 0 SCALE: N.T.S. `WATERFLOW SWITCH ® O 0 O 0 J TU WILA FIFE 1/.20 -1 -)it 0 w W Q J 0 1:-: = x a n cn co 5- ---I GENERAL NOTES 1 SCOPE OF WORK EX DEMO DEVICE BACK TO EXISTING FACP'TOjjALIOW FOR NEW DEVICES OPEN WORK AREA ± 16'-0" X 60'-0" OFFICE tT6 X12'-6" 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT, OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY 'AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 15CD RECEPTION. ± 174r X1 9'-)3* COPYIFILE t.62SF HOL 4.7K i2 TE t 4'- X 9'41! 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE INSTALLING NEW NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. 10. FIRE SYSTEMS WEST WILL FIELD VERIFY NOTIFICATION DEVICE CANDELA SETTINGS AND ADJUST AS REQUIRED. FUSE NETWORKS FIRE ALARM PLAN FIRE ALARM SYSTEM INFORMATION INSTALLER/SUPPLIER SITE CONTACT: FUSE NETWORKS DESIGNISUPPLIER: FIRE SYSTEMS WEST, INC. 700 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C TUKWILLA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735.0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE. FIRESWI055LW aa12' SCALE: 1I8"=1'-0" DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833,1248 FAX: (253) 735.0113 Fire Alarm Symbol Legend SYMBOL DESCRIPTION PART NUMBER MODEL QUANTITY UL FM B 75CD HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING HSRC HSRC 2 S2652 Approved 015CD HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING HSRC HSRC 1 S2652 Approved •/o\ 15CD STROBE, EXCEDER 24V, M -C, RED, CEILING STRC STRC 2 S2652 Approved (0.1024V) EOL 4.7K EOL -4.7 EOL -4.7 1 148.0000mA 20.1476V I EOL IR, Q EOL 4.7K Circuit Calculations Panel: P1 Card: 01 Circuit:SIG1 CircuitName: SIG1 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 2.0000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop 5495 Panel REMARKS 20.4V SMOKE/ HEAT DETECTORS 6 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 31'-0 61.0000mA 20.3048V (0,0952V) 7 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 38'-0 82.0000mA 20.2024V (0.1024V) 8 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 75CD 25'-0 148.0000mA 20.1476V (0.0548V) 9 HSRC HORN/STROBE, EXCEDER 24V, M -C; RED, CEILING, 75CD 44'-0 148.0000mA 20.0911V (0.0565V) 10 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 27'-0 61.0000mA 20.081V (0.0101V) 165'-0 500.0000mA Total Current: 500.0000mA (Total VDrop Percertit:1.56%) Total Voltage Drop : 0.319V p Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City . standards. Acceptance is subject to errors and omissions which do not: authorize "iolations of adopted ,:. ndards and oroinaflces. The responsibility for the )dequacy of design .0 P'srs totally with the designer, Additions, deletioom ;'evisions to these drawings after :his date will void tr11v ,.cceptance and will require a t esubmittai c)i `•e;vi'r`r-` Drawings for subsequent approval. Final acceptance i subject to field test and Inspection by The Tukwila Fire Prevention! Bureau. Date: S--" I - I g _By: U VILA FIRE DEPARTMENT Please call 206-575-4107 anct give this Fire Permit No, 1 - r -o C rid exact Edda v.:as for shut jov4'n or restoration approval. NICET LEVEL 11146053 1412 FPLP 16/2 FPLP EXISTING LOCATION (SWAP FOR NEW DEVICE) WEATHER PROOF NEW DEVICE RELOCATE •STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. • 30 FT. CLG. HT. 15 cd = 20'x20' 30 cd = 20'x20' 75 cd = 20)(20' 30 cd = 30'x30'. 75 cd = 30'x30' 95 cd = 30)(30' 75 cd = 40'x40' 95 cd = 40'x40' 110 cd = 40'x40' 95 cd = 50'x50' 110 cd = 50'x50' 115 cd = 50'x50' r FIRE ALARM SYSTEM OPERATIONAL MATRIX ALARM TROUBLE SUPERVISORY MISCELLANEOUS 1 CAUSE A. �v4 p� v� v� JGg14(' Q`si , ���S�� �ci4%4 Qi�ppp" p��* 4�C949 014.01 R O O REMARKS SMOKE/ HEAT DETECTORS 0 0 0 0 0 MANUAL PULL STATION 0 0 0 0 0 SYSTEM RESET 0 SIGNAL SILENCE 0 0 AC POWER FAILURE 0 0 0 FIRE ALARM TROUBLE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS 0 0 0 TAMPER SWITCHES 0 0 0 `WATERFLOW SWITCH 0 0 0 0 0 J TL1k91,1 srTaily° Fun Cealters&,,; VICINITY MAP PAID •-_ 1 �n1 SCALE: N.T.S. TUKWIL.AFIRE C .2-ov 21=1142212) €11112 011211111=112213 COD CZE1111=1111210 CM) CESE4211111=41112 C3=1211111291:212 =2 CID CC '*ATE lir Without Comments Q As Noted In Red O Per The Attached Letter se plans have been reviewed by The Tukwila Fire •?ention Bureau for conformance with current City dards. Acceptance is subject to errors and sslons which do not authorize violations of adopted dards and ordinances. The responsibility.for the quacy of design rests totally with the designer. itions, deletions or revisions to these drawings after alb CUD C=116111 11121116 411111=111=21 OPEN OFFICE l ■ ■ OPEN OFFICE PRIVITE OFFICE INTERCEPT EXISTING - CIRCUIT resubmittal of revised drawings for subsequent appr val. :=ina1 acceptance is subject to'neld test and inspectiot by The Tukwila Fire Prevention Bureau. vete: II' 1 �- I By: / 141^► J' I ■ • ■ i 0 1 0 1 PRIVITE OFFICE CONFERENCE IN1 CIF ELEVATOR LOWY ■ ■ ■ SERVER OPEN TO BELOW INTERCEPT EXISTING CIRCUIT 1 1 a 1 0 1 II 11 11 11 11 II 11 11 II 11 11 Id RECEPTION 1 FIRE ALARM PLAN SCALE: 1 / 16" = 1' - _ NOTICE 1 SECOND FLOOR PLAN A completed,. signed, Tukwifa° 5 'a 107'1'a Fre .Department Pre-test �" Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a_Re-inspection Fee and termination of the testing NORTH Froula Alarm Systems, Inc. 861 Industry Drive Tukwila, WA 98188 206-575-1962 i 1 CONFERENCE 30 c BREAK INTERCEPT EXISTING CIRCUIT Equipment Legend Symbol Quantity Part Number Description Back Box 0 — Fire Alarm Control Panel Included .1-1pp 0 — Fire Alarm Power Supply y Included 0 — Remote Annunciator Included RA O0 - Photoelectric Smoke Detector 4" Square O0 - Heat Detector 4" Square 0 — Manual Pull Station 4" Square F X1 2 HSR Wall Mount Hom Strobe 4" Square 2 STR Wall Mount Strobe 4" Square OIJ g1 HSCR Ceiling Mount Hom Strobe 4" Square 0 0 — Ceiling Mount Strobe 4" Square DD 0 BY OTHERS Duct Detector INCLUDED 0 BY OTHER Water Flow Switch 4" Square ® BY OTHERS Tamper Switch 4" Square ft0 WIRE LEGEND A- 18 GAUGE 2 CONDUCTOR 'FPLP' B- 14 GAUGE 2 CONDUCTOR 'FPLP' C- 18 GAUGE 4 CONDUCTOR 'FPLP' D- 14 GAUGE 4 CONDUCTOR'FPLP' NOTES: 1) ALL WORK TO CONFORM TO NFPA 72 AND NEC STANDARDS 2) WALL MOUNT HORN STROBES AND STROBES TO BE MOUNTED 80"-96" AFF OR 6" BELOW CEILING WHICHEVER IS LOWER. 3) PULL STATIONS TO BE MOUNTED: A) 48" - 53" AFF B) WITHIN 5' OF THE DOOR. 4) FIRE ALARM CONTROL PANEL TO BE ON DEDICATED CIRCUIT 5) WIRING METHOD TO BE OPEN CABLE UNLESS BELOW 7' AND EXPOSED, THEN IT WILL BE CONTAINED WITHIN CONDUIT. 6) SMOKE DETECTORS TO BE INSTALLED: A) MORE THAN 36" FROM ANY HVAC DIFFUSER B) NOT IN CLOSE PROXIMITY TO FLUORESCENT LIGHTING C) AT LEAST 6" DOWN FROM PEAK IN SLOPED CEILING 7) ALL JUNCTION BOXES, MUD RINGS AND BOX COVERS TO BE PAINTED RED (INSIDE AND OUT). 8) EXTERIOR HORN STROBES TO BE MOUNTED IN THE TOP 2/3 OF THE BUILDING STRUCTURE FACING THE ANTICIPATED FIRE DEPARTMENT ACCESS ROAD. 9) ALL DEVICES ARE EXISTING RELOCATED. NO ADDITIONAL DEVICES TO BE INSTALLED SO THE BATTERY CALCULATIONS WILL NOT CHANGE. PAID FIRE ALARM PLAN (Th LEGENDS SCALE: NONE. SCALE: 1 / 4" = 11- 0" 1--"A� NOTES SCALE: NONE FEB u 6 2014 ..`UK'vBILAFIRE cc PO DESIGNER OF RECORD Kristopher Conner NICET IV 69311 `ti LA FIRE DEPARTMENT can 206.575-4407 and Ay this Fire Permit No. 1 eta;. address for shut- down restoration approval. wo 0(0 CD N 0 rivN = >a: ao rn OWE zoQ OE- oo Z 10E- (1)0 5 DATES SUBMITTAL: FEB 3, 2014 REVISION: SHEET TITLE FIRE ALARM PLAN SHEET NUMBER FA -1 A CE 1' As Noted in Red Tp Per The Attached Letter se plans have been reviewed by The Tukwila Fire 'ention Bureau tor conformance with current City -dards. Acceptan:.e is subject to errors and ssians which clo : <r..t c,utharite violations of adopted -dards and ordinanc;:„s. The responsibility for the quacy of design res"s toiz;iy with the desfgncr. -tions, deletions c . revidous to these drawings after date will void this ;c,.:ept oce and will require a ubmittal of revised drawings for subsequent approval al acceptance is s .l%::tec t to field test and inspection b Tukwila Fire. TUKWILA FIRE DEPARTMENT Please call 206-57541V aild give this Eire Permit s No. and exact add: ess for shut- down or restua .ion approval. EXISTING SMOKE DETECTOR CIRCUIT ELEVATOR LOBBY FIRE ALARM PLAN - SUITE 210 } SCALE: 1 /8"= 1'-0" E-21 BUILDING PLAN SCALE: 1 / 16” = 1' - 0" Equipment Legend Symbol Quantity Part Number Description Back Box 1 D9412 Fire Alarm Control Panel Included 1 10i; _� 1 5495 Fire Alarm Power Supply Included O3 SD355 Existing Photoelectric Smoke Detector 4" Square 1 HSR Wall Mount Hom Strobe 4" Square 1 STR Wall Mount Strobe 4" Square ID T29 PC2R Ceiling Mount Hom Strobe 4" Square 0 38 SCR Ceiling Mount Strobe 4" Square NOTES: —\AAr-)2( )2( )2( )2( )2( 1) ALL WORK TO CONFORM TO NFPA 72 AND NEC STANDARDS 111 JEN`1` KN I(.: 11'1. NW Healthcare Kristopher Conner 2) WALL MOUNT HORN STROBES AND STROBES TO BE MOUNTED 80"-96" AFF OR 6"BELOW CEILING WHICHEVER IS LOWER. 495 Power Expander Calcu(a Version 02 18.09 11/22/2013 WIRE LEGEND A- 18 GAUGE 2 CONDUCTOR 'FPLP' B- 14 GAUGE 2 CONDUCTOR 'FPLP' C- 18 GAUGE 4 CONDUCTOR 'FPLP' D- 14 GAUGE 4 CONDUCTOR 'FPLP' 3) PULL STATIONS TO BE MOUNTED: A) 48" - 53" AFF B) WITHIN 5' OF THE DOOR. )2( )2( )2( 4) FIRE ALARM CONTROL PANEL TO BE ON DEDICATED CIRCUIT 5) WIRING METHOD TO BE OPEN CABLE UNLESS BELOW 7' AND EXPOSED, THEN IT WILL BE CONTAINED WITHIN CONDUIT. 5495 Pwr Module 5495 Circuit 1 cfg. 5495 Circuit 2 ctg• 5495 Circuit 3 5495 Circuit 4 #14 Solid #12 Sohd #12 Solid 0.060 #12 Solid #.12 Solid 6) SMOKE DETECTORS TO BE INSTALLED: A) MORE THAN 36" FROM ANY HVAC DIFFUSER B) NOT IN CLOSE PROXIMITY TO FLUORESCENT LIGHTING C) AT LEAST 6" DOWN FROM PEAK IN SLOPED CEILING 7) ALL JUNCTION BOXES, MUD RINGS AND BOX COVERS TO BE PAINTED RED (INSIDE AND OUT). 3.72% 0.00% 0.00% 0.00% 0.00% Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the ninin-al difference between sold and stranded wire no differential was trade. IPS TO ADJASCENT POWER SUPPLY FOR TRIGGER TO UNSWITCHED 1 2 DEDICATED 120VAC POWER 2 system senior P2/PC2Horn/Slrobe (754 System Sensor P2/PC2 Hom/Strabe (3Q4 8) EXTERIOR HORN STROBES TO BE MOUNTED IN THE TOP 2/3 OF THE BUILDING STRUCTURE FACING THE ANTICIPATED FIRE DEPARTMENT ACCESS ROAD. t'Pah nn 1 Dnuuer -C, mnhr i'nnM '1.1 Totals `=,O. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will resp.}4r in a Re -inspection Fee termination of LEGENDS SCALE: NTS 4 NOTES J SCALE:NTS RISER DIAGRAM SCALE: NTS BATTERY CALCULATIONS SCALE: NTS .2 PAID MP'/ 2.,t ?p1:1 P � °v1L i „.1 F -2- f 37 Froula Alarm Systems, Inc. 861 Industry Drive Tukwila, WA 98188 206-575-1962 DESIGNER OF RECORD Kristopher Conner NICET IV 69311 0 Nr— N !is)U 00 .0 o0 �coCD Q c a) a)co � 0 § -0t o �� Z � 0 0 ti DATES SUBMITTAL: REVISION: SHEET TITLE FIRE ALARM PLAN SHEET NUMBER FA -1 LS1:7\T IJCiI!IC INC. 7100 FORT DENT WAY TUKWILA, WA 98168 Device Legend FACP FAA PS P IRI T JP ISI FP WP VS WF GV HSC LF Fire Alarm Control Panel Fire Alarm Annunciator Power Supply Smoke Detector Pull Station Relay Module Tamper Switch Jockey Pump Controller Wall Mount Strobe Ceiling Mount Strobe Wall Mount Hom Strobe Ceiling Mount Hom Strobe Low-Freq. Wall Mount Horn Strobe Mini Horn Fire Pump Controller Weather Proof Sprinkler Valve Supervisory Switch Sprinkler Flow Switch OS&Y Gate Valve Wall Mounted Smoke Detector Non Addressable Heat Detector Fire Fighter Phone Hand Set Center Low Frequency Sounder Wiring Legend A B C D E Denotes Ckt. Number 14 Gauge 2 Conductor FPLP 18 Gauge 2 Conductor FPLP 18 Gauge 4 Conductor FPLP 17 Gauge 2 Conductor FPLP Category 5E Cable Typical Mounting Height FACP FAA P S EK PS Q EK WP 60" To AFF 60" To ¢ AFF 46" To ¢ AFF 48" To ¢ AFF 80" To AFF 80" To ¢ AFF 60" To ¢ AFF 4"-12"(MAX) To t From Ceiling 8'-101(MAX) To ¢ From Floor Notes 1. 2. 3. 4. FA1 COVER PAGE --------)11111111111111111111 BEVERAGE BAR AREA 202 TO P.S 1A 3 mTrfTTTTT 1 n 1 r[ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 FIRE ALARM RISER LEVEL 1 P.S P.S CKT 1A 7 INI 30 E.O.L L11111111I 1 RECEPTION 201 7 / / / / / / / 1111111 III IIIIIIIIIIIIIIlI 1111111 111111111111111111 I FEC WORK AREA 230 85 / / / / / / / / 11111111111111111111111 116 /S^ ACCOUNTING 222 ♦15 / / / ACCOUNTING 221 / / / / / / / / / / / / / OftmmioNftwowg DN. STAIRS 15 / / / / / / / / / / FEC CORRIDOR 220 30 KITCHEN BREAK E.O.L 219 P.S 1A 1111111111 1111111111111111 v/ / / / / / / / / / / / / / / / / / / / / / / /lo _11111111111111111111111111111111111 II 111111111111111 11111111111111111111 31 111111111111111111111111111111111 FIR 3/16"=i'0" ALAR V LA`/OT p Without Comments As Noted in Red rp Per The Attached Letter These plans have: been reviewed by The Tukwila Fire Prevention Burerl.,. >1' :onformance with current City standards. Acceo :- , r. Subject to errors and omissions which tj : , i..,thorize violations of adopted standards and The responsibility for the adequacy of desit r:,,otally with the designer. Additions, deletions .::.visions to these drawings after this date will voi6 r, :- :ebtance and will require a resubmittal of = vi :'t' E: °- ,,,vir25 for subsequent approval. Final acceptance i :° I, , t field test and inspection by The Tukwila Hie P evenrrorl Bureau. Date: 1-13 -/ 7 By:_, t � E r,sv� 1414,1/4.41 r at I s kin," a,4 elc4 $ t) . TUKWILA FIRE DEPARTMENT Klan call 206-575-4407 and give this Fire Permit No. and exact ad i ss for shut- down or restoration approval. PAID ►.wig WKWILA FlPtc 00 O 4-4 0 Revisions: aQ o 0 _ ❑ u. m a) ❑ r, 1/9/2017 Drawn By: RS eeSli t�umirer :. FA1 Fire Alarm Symbol Legend SYMBOL DESCRIPTION PART NUMBER MODEL QUANTITY USER TEXT UL FM 1:0:( RADIONICS 2 -WIRE, HORN STROBE, RED, WALL D570S D570S 10 EX SMOKE I HEAT DETECTORS 0 RADIONICS 2 -WIRE, HORN STROBE, RED, WALL D570S D570S 2 0 ;0; ft ® Without Comments As Noted in Red ® Per The Ai.achedi Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau f'nr conformance. +:t. il:h current City ndards. Accepri:'•rl:..: S' subject roi 9!IR,`'i.?1-1d 1 nissIonS'vhIC1': rl'1 :''fa; :;1.19"horIze viol-4ions 1::1 adopted -,a, (:lards and arc*, ,,.c ::. The resuonsibiiity for the :cie,,quacy of de sic. totally with the designer, Additions, deIerfons %Isions to these drawings after i:Ns ,iFte 11., •icceptance and will require a resubn?I; . .. vii!ngs for.. subsequent approval. Final acceptance is subject to field test and inspection by Tne Tukwila Fire Prevention Bureau. Date: 11- 8-1 By: kr"- rt T . s'71It-A FIRE' DEPARTN NT r-. ;I 20.5-5M-140 and give this Fie Permit N®. and exact address for shut- down or restoration approval. WOOD-RICHARDSON & CO. INN Ell pp B k SCALE: 1/8" =1'- 40" 12' 20' FIRE ALARM DEMO PLAN ' FIRE ALARM SYSTEM OPERATIONAL MATRIX DESIGNISUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY , SUITE 225 ALARM TROUBLE SUPERVISORY MISCELLANEOUS I CAUSE 41. co y��Q� ��P�Pa�o�S O0v JPO �cP ..cd-" Jp\0N'0 GQ sl, 4. is is Ns �6 0 e*PSP �P'� v- Zo J1t.1, 4�,��s4'• c, C.. 4' 4 N, Y.0' r N- io ,r,Q�4°4° 4 4 4s1 eo0',.-0 WA ST LICENSE: FIRESWI055LW REMARKS SMOKE I HEAT DETECTORS 0 0 0 0 0 MANUAL PULL STATION 0 0 0 0 0 SYSTEM RESET 0 SIGNAL SILENCE 0 0 AC POWER FAILURE 0 0 0 FIRE ALARM TROUBLE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS 0 0 0 TAMPER SWITCHES 0 0 0 WATERFLOW SWITCH 0 0 0 0 0 WOOD-RICHARDSON & CO. 1111111 1 .,,..,r111111,, �1■ pB 4 SCALE� 118=1$30" 12' 20' FIRE ALARM PLAN GENERAL NOTES 1 SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F•P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE WILL IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL RELOCATING EXISTING FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. 10. Verify voltage drops and calculations in field before final test. Provide results to AHJ. FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER SITE CONTACT: WOOD-RICHARDSON & CO. DESIGNISUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C SUITE 225 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735-0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE: FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833.1248 FAX: (253) 735-0113 X FOR FIRE DEPARTMENT USE ONLY Fire Alarm Designer Bryan Hilfiker SET NICET III 99709 Bryan Hilfiker A B EX WP N R 14/2 FPLP 1612 FPLP EXISTING LOCATION (SWAP FOR NEW DEVICE) WEATHER PROOF NEW DEVICE RELOCATE •STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 20x20' 30 cd =20'x20' 75 cd = 20'x20' 30 cd ■ 30x30' 75 cd m 30'x30' 95 cd ■ 30x30' 75 cd - 40'x40' 95 cd m 40'x40 110 cd = 40x40' 95 cd = 50x50' 110 cd = 50'x50' 115 cd = 50)(50' WORK AREA t Digitally signed by Bryan Honker DN:cn.Bryan -Fire Systems ;Wert, Inc...Spokanetxlke, emaB.BryanHmHresystemsWest.com, Da t e: 2017.11.01 13:4240 -0708' Lance Tarim nufncture€n.ldin; Fiomavuood Suiies' tiilion.SeaiiI Tacoma; ertia ?all GUy R.,V $ BaauSiora Tukwila Family 'Fun Cunler 4 .' UBW t `vR gill VICINITY MAP PAID SCALE: N.T.S. NT/ 03 2011 TUKWILA FIRE Fax: (253) 735-0113 00 M C+ ) c0 LC) WA CO FIRESWI 140B1 0 z 0 0) ce ISSUED_FOR_REVIEW 0 z EW DEVICE COUNT J 0 z c 0 r) w I— x w 1- x w 1- w I~ w w rr- w 1- 2 w 1- J w 0 N 0 0 ce CL MS -7 SERIES LL a ILL SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR GAMEWELL FCI GAMEWELL FCI GAMEWELL FCI GAMEWELL FCI CEILING HORN STROBE OUTDOOR WALL HORN STROBE WALL HORN STROBE WALL STROBE PULL STATION SMOKE SENSORS HEAT SENSORS ce 0 z e WOOD-RICHARDSON & CO. FIRE ALARM PLAN W z LU co • Z U Urn—I ?C) a� `r 0 0r'CO rn 00 C C co ceiV Z v) >- -J (J) 0 0 w 1- 0 RD O rs- 00 1-'- W 0 a. FILE:Wood-Richardson & Co. Fire Alarm Plans.cad DATE:10/31/17 TIME:15:59:13 — • LEND 0 101 EXISTING WALL TO REMAIN NEN OFFICE PARTITION WALL PER DETAIL I/A2 EXISTING FURS OUT OF EXISTING COVE WALL PANELS BUILDING STRUCTURAL COLUMN BUILDING,. GRIDLINE DOOR NUMBER (REFER,ENCE DOOR SCHEDULE) RELITE NUMBER (REFERENCE RELIT E SOHEDULE) ROOM NUMBER (REFERENCE ROOM SCHEDULE) ELEVATION DESIGNATION CEILING, GRID EXISTING 2X4 (5) TUBE RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN 2X4 (3) TUBE RECESSED FLUORESCENT LIGHT FIXTURE EXISTING GNI5 CEILING •<:)- EXISTING CAN LIGHT FIXTURE TO REMAIN DETAIL DESIGNATION NEN EXIT SIGN LOCATION KEYNOTE DESIGNATION DUPLEX OUTLET FOURPLEX OUTLET POWER SUPPLY FOR SYSTEM FURNITURE DATA LINE SUPPLY FOR SYSTEM FURNITURE KEYNOTES I. REFER TO DETAIL 5/A2 FOR IMPORTANT DETAILS OF PONER/DATA PHONE RUNS BELOW WINDOW SILLS. 2. VERTICAL BLINDS (SEE RELITE/FINISH SCHEDULE). • PERIMETER WALLS HAVE /MEN FURRED' AND INSULATED (RI5) UNDER THE BUILDINEYS SHELL PERMIT. 6YP. BD. HAS SEEN TEMPORARILY PLACED (NO TAPING) FOR REMOVAL DURING POWERING UP OF TENANT SPACE. REINSTALLATION, FURS OUT DETAIL SHOWN IN 5/A2, TAPING AND PAINTING ARE A PART OF THE SCOPE OF WORK UNDER THIS CONTRACT. • 1 11 I - I 11 1 L L \.••• STAIR P2 121 -of " 10 -0' '-O" ,1 0 ADJACENT LA!AREA 10I -Oft 5'-0" • VERIFY - -40••••••••••••••••••14-. STOR. ILDINS '51-2" 0 OPEN OFFICE 206 „ cokFERENce 202 0 1445-11 ri 71-4" 4'-t t1 MIN.. CZI MA T. R1.! 25'-0" 25'-0" 25'-0" FLOOR FLAN co 21•11, FLOOR SCALE: I/8" = . , • ... • " •-•-•: , • _ s!; • "•*;,' -•. TA1R •-• Jo • C=NT E1AREAi- • • • - • • ; =0.1NOMMI ! • . sa Al 111, 206 ; • • :re R FLECTEDCLG. FLA SCALE: 1/8'= I'0 Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and Will require a resubmittal of revised drawings forsubsequent approval. Final acceptance is subject to field test and ins cti • S4.A.t. chtti TUKWILA FIRE DEPARTMEN1 Please call: 575-4407 and give this job No. q‘q r•-/76 and exact address for shuti down or restoration approval. •-4-1*PlYinell fie-rei dm, Bureau: -1,00R SCHEDULE - Date: / By: 5(-.1./ 1700R * POOR SIM DOOR TYPE FRAME HRS GROW . . J.!FINISH - : - REMARKS ' . .........a. • EXISTING TO REMAIN , . -- • ' - SEE. COLOR SAMPLE 4/15/cf4i - . .. EXISTING . • 01 5'-O" X 81-0" X 1 5/4" ' SOLID CORE 104001, DOOR/MAPLE VENEER NOOD FRAME A SEE COLOR SAMPLE 4/15/4101 .. . , 02 31Q1 X 610" X 1 5/4" SOLD CORE loslOOD DOOR/MAPLE VENEER ' KOOD FRAME ' A . sEE COLOR SAMPLE '4/15/41c1 05 5'-O" x a* -o" x 1 5/4" ! SOLID CORE IAIOOD DOOR/MAPLE VENEER- • HOOD FRAME A -- .. EE COLOR A LE 4/15/c141 DOOR LOCKED . 04 5'-0" X 8'-0" X I 5/4" SOLID CORE V4002-00R/MAPLE VENEER NOOD FRAM!. . A . . EE! COLOR SAMPLE 4/15/0141 ! 05 5-0" X 6'-0" X I 5/4" -SOLID CORE WOOD POO APL VENEER WOO. FRAME A - SEE COLOR-AMLE 4/15 4141 . - DOOR LOCKED 06 5-0" X 6'-0" X I 5/4" SOLID CORE 1•4001, DOOR/MAPLE VENEER - . . HOOD FRAME . A SEE COLOR SAMPLE '4/15/4441 . DOOR LocKED . . . . • .. , . I TE'i'SCHEULE . .. RELITE * RELIT! SIZE .. . . . 01 ' 45.-o"XFULL 1-4T.(l'-0") THROATED 1^100D .. SAFETY.•GLAS •VETICAL BLINDVI5.71 , 02 .61-0"XFULL HT.(11-09- THROATED NOOP. SAFETY GLASS FIELD VERIFY I RTICAL SLIM'S V5-1 05 I'-0"XFULL HT.(71-0") THROATED 1A1000 - SAFETY -GL AS .. . . . ,,.. . . . . . . ,. • . . • • . . . ROOM FINISH 5 -4 U E CEILING . . . . .. . . • . F1..00R .... . ., REMARKS , ROOM NAME FINISH HEIGHT , FIN SH. .• SASE. NORTHNEST * ..SOUHNEST SOUTHEAST NORTI-EAST ' 201 ENTRY' ACOUSTICAL Cl...e. GRID '-6"! CARPET/C1 , RUBSER/Rf3-1 . HS/PAINT/DOOR P -I. 61,43/PA T P -I. - GNE3/PAINT ..P-1 , Gk/PAINT P -I 202 CONFERENCE ' ACOUSTICAL CL.G. GRID 6-6" CARPET/C;7:1 . . . SUEOEFt/133;-1 - ' 6H5/PAINT . P -I 6HE3/PAINTAN INDON P -I GH15/PAINT PLI 61,45/PAINT P-1 205 COPY' ROOM , ACOUSTICAL CLG. GRID , 61-6" - VCT -2. , RUE3SER/Rfir3 - .- 645/PAINT -P-1 '. SKS/PAINT/DOOR P -I , 61'45/PAINT P -I GINEWPAINT P-1 204 . OFFICE • ACOUSTICAL CL6. GRID 81-6" , • • -RtABBER/R13-1 :, -• GKE3/PAINT P -I . eke/PAINT/WINDOW P -I 6K5/PA1NT P -I G /PAINT P-1' 205 KITCHEN ACOUSTICAL C.L.GRID ' ,CARPET/C-1 &'-b" - VCT -2- „ . . . RUISBER/R13"3 , - .N5/PAINT P-1 ! 6Y45/PAINT/D00R P -I - Gi"45/AINT P -I . Glee/PAINT P -I . 206 STORAGE ROOM ACOUSTICAL CLG. GRID 't" ' VCT2 . - . . • RUBERigS 3. ---611%15/PAINT P-.1 6HE3/PAINT/0OR PI 6HE3/7:1,,,,INT. P1 G5/FAINT P1 207 . PBX AC0UT1CAL.'0LG. GRID' . . '-6" •,- . VC:1-2 - RUBER/R.8 -3 - . '614/PAINT/0C* P -I r 61"0/AINT P -I : HEs /AINT P -I - GIAl5/PAINT P -I 208 OPEN OFFICE ACOUSTICAL -CLG. GRID . .5'6" - 61.113/PAINT/00R P I._ GIAIEVPAINT/1/41N1,01,41 P-1 61,41E3/PAINT - P -I •. , GIAIB/PAINT P -I CARPET/C-d - - . 20c1 • EXISTING BLDG. COMMON CORRIDOR • , _ EXISTING 1 HOUR CORRIDOR . 7- - • .. - . . ' • , .. . -,,,, • • 1 , . . .. , . . . . . HRDIAIR SCHEDULE . . , - -i-- :FINISH r . ' SCHEULE -. . • .. HARDKARE A . 3'-orx8o-o.xl 5/4" SOLID CORE 1"100'D DOOR 2 PAIR BUTTS 4 1/2 X 4 1/2 I LEVER.PASSAESET 1 NALL.STOP .. 5 SILENCERS . .. G -I , CARPET COLLINS AND ALKMAN ' "LUM1NARIE" . . COLOR: ' GRAPHITE 41205 1"1/RS BACKING 6'INIE BROALOOM, .DIRECT 61, -..UE DOWN - LOS ANGLESlEP.: , MS.. ANNE PROOKES • (800). 241-4402 EXT. 1666 • r114) 663666 NOTE: HYUNDAI 1'4ILL PROVIDE CARPET C -I LP -I• - . .. ' PLASTIC LAMINATE NEVAMAR COLOR: FDLATINUM GRAY PS -5-25T . . . .. '...- 1::.,I'! , ..PAINT -.----- ' DUNN E.DARDS.. • . -. .COLOR: 106 DAs1N EGGSHELL OR TOMATCH . ' ' . - . . RS7S . '• • ' , , , RUBBER -BASE ..BURKE ,.COLOR: - PLATINUM PI45P ' '• 4" HIGH OVED-15ASE AT VCT ' VCT -2 ARMSTRONG - "STEP MASTER, SLIP-RETARt7ANT TILE" - COI -OR: 'SLATE P5072 12°X12'X147V GAUGE LOS AN6ELEs- REP-.: M5, LAURA HUBBARD (800). 55675G01 'EXT.- 541c15 . - 1.17-; , : . , . . . _. PLASTIC LAMINATE '-• HILSONART • - - • . •- COLOR: .BLUE NEBULA *46266' - .... • . - ' . . .Rip - -1 -- . . .- • . --RUSSR SAE. • . • BURKE --- -• • • .. - - . - COLOR: STERLING *665P - ' 4" HIGH !STRAIGHT BASE AT CARPET , . ry40-1. . • ' fr4000. VENEER ' . PREMIUM GRAD; PLAIN. SLICED MAPLE, MEDIUM FIGURED ' . • STAIN i TO MATCH SAMPLE '- . • . . . . , , '." ' . . . :VE3-I -.. ' ' VERTICALlBLINDS • LORERAPE- • (TOBE VERIFIED IF REQUIRE) . ELITE: TRAcK, CEILING MOUNTED c..OLOR: ,.PERPORATF-D INHITE r • ' REP::- ' LOS ANGELES FILE MR. NILSANDERSON - ' - ' - (600'626-V19cl. .- EXT. 5Cr701 .... .... . . _ , .... . , ,..• - : - . ! P -I -• . PAINT ' UNN- EDIAtAPP-DS - COLOR: -106 DANN, EGGSHELL OR. TO MATCH -' . . .. , . LP -.5. - PLASTIC LAMINATE- , ,NEAMAR,! . COLOR= . St -JOKEY WHITE *ST1-21T.- : . . ... . • . . . . , . •' ' • ,. ••• . • •. , . .. , . ,". . - . . . . , . -:.FP.E3-2 . - r - RUSASEE - .BURKE-.• . ..COLOR:- aLt1-1.1,41-HITE *168P .: ' - . .. 4" Hicki COVED.!BASE AT VCT:.-..,- , : , -..• ,, •.. • . . - • • ,•- • • : ... .•, _ . • • • Ft.tihAtil DtSiGN GROUP PROJECT: HYUNDAI AMERICA SHIPPING AGENCY INC. Fort Dent III 7100 Fort Dent Way . ' Tukwila, Washington .98188 SHEET INFORMATION: FLOOR PLAN; REFLECTED CEILING PLAN; LEGEND; KEYNOTES; SCHEDULES JOHN C. RADIVICH DEVELOPMENT 2000 124th Avenue N.E. Suite #B-103 Bellevue, Washington 98005 • HYUNDAI WASHINGTON • c/o Landmark Management 879 West 190th St., Ste 400 Gardena, CA 90248 • REVISIONS: • C:\IF:GDWG\95\96135.16\813516A14wg • • OxRELELF(: TlIEFwRIFMERRAinirrENANy 041);E:RSIriGNIsiExcepTC:UrRotAP. 1004: iAN: • -„ ALLFERRARRIG1 CGOWC0RAinswINGslserE\ARsiptseci:01.E.p113:ppRollr3E5T1996Xii.89.Fdw cr AR- NOT .70' 13E USED OR REPRODUCED - . • ; ,•• JUN 0 31999:: go! cfeckedBy: FH Drawn By. PSCOTT Date: • • : April 28,1999 Sheet No.: , 1 CONSTRUCTION DRAWINGS- TRAININ e STOR 20 WALK— CL. 2t9 11 OPEN OFFICE 205 ///,/////////////,/,// / / / / / / / / / / FFICE 204 / / / / / / / / / / / ////,//, //,////l 0 ICE 03 ADJACENT TENANT TO FACP/POWER SUPPLY RECEPTION 206 207 STAIR 202 BUILDING COMMON CORRIDOR VOCATIONAL ROOM 211 CLASSROOM / / / / KITCHEN/ 210 / 201 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / I/ / / / / / / / / / / ADJACENT TENANT 25'-0" 25'-0" 50'-0" LEGEND x STROBE ONLY RADIONICS D506S/I5CD HORN/STROBE RADIONICS D574/75CD POWER SUPPLY: SILENT KNIGHT MODEL #: SK5395, 6 AMP. NOTE: THIS POWER SUPPLY IS FOR THE CLINIQUE T.I. & ANY FUTURE OR ADDITIONAL 2ND FLOOR T.I. CCS ❑,, Without Comments As Noted In Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings forsubsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date:_kp I . i9. By: 45.- r TUKWILA FIRE UEPArti'�vi�IVi Please call: 575.4407 and give this job 03 and exact address for stnit. down or restoration afiorQV4i, r FILE CLINIQUE SERVICES INC. FORT DENT III 7100 FORT DENT WAY TUKWILA, WA. 98188 DESIGNER: JIM O'DONNELL GERRY VUCCI DRAFTING: TRAVIS MCCLURE EaULIEITT WA. LICENSE #044QF DATE: JUNE 7, 1999 SIZE D REV NEW AUDIO/VISUAL FIRE SCHEMATICS SCALE NONE SHEET 1 OF 1 N IT JUN 21 ;qqq 140'-0" 20'-0" 25'-0" 1 25'-0" i 25'-0" c5'-0" TO FACP ZONE 4 immk/AL Aka ai 4 NEW 12' HIGH GYP, BD. SOFFIT TO FACP ZONE 3 DLAN BREAK: ZONE CONTINUATION TO UNIVERSITY OF PHEONIX FOR POWER REQUIREMENTS. CU 0 CD En L N,'G hND HORN/STROBE: RADIONICS D572S 110 C.D. MINI HORN/STROBE: RADIONICS D559S 15/75 C.D. POWER SUPPLY: SILENT KNIGHT MODEL #: SK5395, 8 AMP. NOTE: ALL DEVICES NOT ACCOUNTED FOR IN RUN FEEDS "I" THRU "4" ARE EXISTING, AND WERE INSTALLED IN ORIGINAL PERMIT DATED 03/08/99 # 99F06A, FINALIZED 04/15/99. CCE TE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for.subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /. By: TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job No.��" and exact address for shut= down or restoration approval. r IIL liMMEWM Ai JUL iq 1999 00•41114011*•1116 epe* PAB THEARAPUTIC ASSOCIATES FORT DENT III 7100 FORT DENT WAY TUKWILA, WA. 98188 DESIGNER: JIM O'DONNELL GERRY VUCCI DRAFTING: TRAVIS MCCLURE DATE: JULY 14 1999 gT1131M1 Aggin[rITV WA. LICENSE #044QF SIZE D REV NEW AUDIO/VISUAL FIRE SCHEMA TICS ISCALE NONE SHEET 1 OF I 0 0 SENTEX PHONE_ RADIONICS READER NEED 2 8004'S & ONE DUPLEX OUTLET. SANYO 'REAL TIME" VCR SMV 16 MUX 12' MONITOR CO' FUTURES FOR TENANT ALARM DATA. BELL CIRCUITS, & KEYPADS. 1T1 6 x 02. SUPRA BOX WITH TAMBER SWITCH s IIIMMIION01•1•16 11.1.O111=1101 BS HS LEGEND 30 CD STROBE ONLY OUTDOOR BELL -STROBE 110 CD HORN STROBE RADIONICS 9412 FIRE PANEL SPRINKLER RISER FLOW VALVE POST INDICATOR VALVE OR INSIDE SHUTOFF SMOKE DETECTOR W/POINT ID DC NOTE: PLENUM BUILDING MANUAL PULL STATION W/POINT ID HEAT DETECTOR W/POINT ID REQUEST -TO -EXIT SENSOR DOOR CONTACTS GLASS BREAKS MAGLOCKS ON FRONT DOORS ONLY CEILING MOUNTED ELMO TSE400 CAMERA IN WEDGE HOUSING [Lc < OUTSIDE VIDEO CAMERA ON WALL MOUNT -WIDE ANGLE ELMO TSE400 1ST FLOOR PLAN 0 0 0 A T El Without Comments 3, As Noted In Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subjea to errors and . OrriiSSiOrIS which do not authorize violations of adopted I standards and orciinances. The resporsilAity for the adequacy of design rests totally with the dgner. I Additions, deietions or revisiens to these drawings artrsr this date will void this acceptance and will squire a i resubmittal of revised drawings for.subsequent approval. 11 Final acceptance is subjectto field test and inspection by The Tukwila Fire Prevention Bureau. Date: 3 By: . arts6t1L lok•Ir‘ -s\--Az-5 rrek v4-. 9t_g,14,:veti,v\?-4 EUKWILA FIRE DEPARTIVIEM Please call: 5754407 and give This lob and exact address for shut. down or restoration approve. LE FORT PORT DENT 111 7100 FORT DENT WAY TUKWILA, WASHINGTON DESIGNER:. JIM O'DONNELL DRAFTING: TRAVIS1MCCLURE OITOCIWUDN VICUIRUT7 WA. LICENSE #0440F FEBRUARY 17 1999 . • °IV NEW FIRE/INTRUSION SCHEMATICS guts 1:150 QF 2 .d MAR 5 1999 FUTURES FOR TENANT ALARM DATA, BELL CIRCUITS, a KEYPADS. f r1 x CD 01 43/ 0 r s BS LEGEND 30 CD STROBE ONLY OUTDOOR BELL -STROBE CM HO CD HORN STROBE RADIONICS 9412 FIRE PANEL SPRINKLER RISER FLOW VALVE POST INDICATOR VALVE OR INSIDE SHUTOFF SMOKE DETECTOR W/POINT ID VC OVC NOTE: PLENUM BUILDING MANUAL PULL STATION W/POINT ID HEAT DETECTOR W/POINT ID REQUEST -TO -EXIT SENSOR DOOR CONTACTS GLASS BREAKS MAGLOCKS ON FRONT DOORS ONLY CEILING MOUNTED ELMO TSE400 CAMERA IN WEDGE HOUSING OUTSIDE VIDEO CAMERA ON WALL MOUNT -WIDE ANGLE ELMO TSE400 ROOF HATCH A-41-4 of_, 2ND FLOOR 'PLAN FORT DENT 111 7100 FORT DENT WAY TUKWILA, WASHINGTON DESIGNER; JIM O'DONNELL DRAFTING: TRAVIS MCCLURE @VEITEMULA @LINNET WA. LICENSE #0440F DATE FEBRUARY 17, 1999 tz .1: NEW FIRE/INTRUSION SCHEMATICS 1:150 s'ea 2 OF 2 FLOO DLA\ @ FIRST FLOO; t1 LEGEND 4 MINI HORN/STROBE ED HORN/STROBE STROBE POWER SUPPLY: SILENT KNIGHT MODEL #: SK5395, 6 AMP. NOTE: THIS POWER SUPPLY IS FOR THE UNIVERSITY OF PHOENIX ONLY NOTE: ALL DEVICES NOT ACCOUNTED FOR IN RUN FEEDS "I" THRU "4" ARE EXISTING, AND WERE INSTALLED IN ORIGINAL PERMIT DATED 03/08/99 # 99F06A, FINALIZED 04/15/99. r FILE 0 ACCEPTED Without Comments As Noted In Red Per The Attached Letter These glans have been reviewed by The Tukwila Fire Preven ion Bureau for conformance with current city standards. Acceptance is subject to errors and omissicns which do not authorize violations of adopted standards E nd ordinances. The responsibility for the adequacy cf design rests totally with the designer. Additions, deletions or revisions to these drawings after this dat wi 1 void this acceptance and will require a resubmittal of revised drawings forsubsequent approval. Final ac ceptance is subject to field test and inspection by The Tu cwila Fire Prevention Bureau. Date- 7i/9 �/ By: UNIVERSITY OF PHOENIX FORT DENT III 7100 FORT DENT WAY TUKWILA, WA. 98188 DESIGNER: JIM O'DONNELL GERRY VUCCI DRAFTING: TRAVIS MCCLURE E@RIMo4rr WA. LICENSE #044QF DATE: JUNE 29, 1999 SIZE D IREV NEW AUDIO/VISUAL FIRE SCHEMATICS SCALE NONE SHEET I OF 1 t1.'Pt VV1LA FIRE OEPARTIVIEar Please call: 575.4407 and give this job No.fa and exact address for shut- down or restoration approval. D)Ircr',71gTVI JUN 3 0 iQaq c77-7 rb) (o%T..Zg-3 /// 25'-0" 25'-0" VOCATIONAL RM. 3 204 1, 25-0" STAIR 201 Y!I 2'-6" VOCATIONAL RM. 1 205 DN STORAGE 203 5'-0" 27'-6" 20'-0" VOCATIONAL RM. 2 206 VOCATIONAL RM. 4 209 MAINT. RM. 210 20'-0" MEN 211 a V • LIMIT OF WORK UNDER THIS PERMIT WOMEN E 212 r FACP D-9(1) TO ZONE 2 ADJACENT TENANT DN STAIR #1 FLOOR PLAN @ SECOND FLOOR 25'-0" ADJACENT TENANT 25'-0" 25'-0" 25'-0" BREAK: ZONE CONTINUATION TO THEARAPUTIC ASSOCIATES FOR POWER REQUIREMENTS. (ZONE 4) _ f DN STAIR 202 BUILDING COMMON CORRIDOR 213 ADJACENT TENANT STUDY RM. #1 217 • 50 pp . - fi M M STUDY RM. #2 218 VOCATIONAL RM. 5 216 VOCATIONAL RM. 7 214 riM VOCATIONAL RM. 6 215 0 N in N 0 LEGEND MINI HORN/STROBE: RADIONICS D559S 15/17 C.D. POWER SUPPLY: SILENT KNIGHT MODEL #: SK5395, 8 AMP. NOTE: ALL DEVICES NOT ACCOUNTED FOR IN RUN FEEDS "I" THRU "4" ARE EXISTING, AND WERE INSTALLED IN ORIGINAL PERMIT DATED 03/08/99 # 99F06A, FINALIZED 04/15/99. LIMIT OF WORK UNDER THIS PERMIT CCE TE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings forsubsequent approval UEPARTiJIENC easeKWILA call:FIRE 575.4407 a d give this job —1"°- 3 y • Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Burea Date: 7 >///1 C% By: S /"Y UL 1 41999 d exact address for shut, wn or restoration approval. B CD/e4f) 1/75 ceAr 1657' �QO j##►Ryz� �. FIL E . 1olo) UNIVERSITY OF PHOENIX FORT DENT III PHASE 2 7100 FORT DENT WAY TUKWILA, WA. 98188_ DESIGNER: JIM O'DONNELL GERRY VUCCI DRAFTING: TRAVIS MCCLURE OTIIFEM11 MMIT-211T1' WA. LICENSE #044QF DATE: JULY 14, 1999 SIZE D REV NEW AUDIO/VISUAL FIRE SCHEMATICS SCALE NONE SHEET 1 OF I INST'LL' : : + N CO x P is IVY: NEY\ELL ECU ' :CITY NIT ING 27 ICI kRI1IS %wxq} ° ®S ITE 2 2 LLE\» JE \/VA 980 #5 Fire Alarm System Check Off List For Final Inspection Following is a list of items that must be completed before the Fire Department will perform a final inspection. 1 Low Voltage Electrical Final 2 Line Voltage Electrical Final 3 Elevator Final 4 Pressurization a Stairwell b Elevator J5 Sprinkler System (100% Complete) All Valves in normal condition. 6 Interior Building Construction. (i.e. doors, floor covering, ceiling covers, ceiling tiles, windows, etc.) 7 HVAC 8 Suppression Systems 9 Safety and ADA Requirements, Fire Extinguishers _ 10 Specialty Furniture _ 11 Monitoring (See Below). _ 12 Final Fire Alarm Inspection 13 Approved Set of plans and permit on site Phone line (lines) must be installed and active. - 14 Fire Alarm Monitoring a Dual Line Communicator b Scan Line Date Line Due In: (If Required by Jurisdiction) c Contract Signed d Scan Line ordered (Alarm Company) e Stu Installed and Tested ▪ 2 Elevator Monitoring Completion Date: Completion Date: Completion Date: Completion Date: Completion Date: Completion Date: Completion Date: eV Mf ID soma Of DEVICE FCRMull. DOM Completion Date: Completion Date: Completion Date: Completion Date: Completion Date: Completion Date: A.D.A. REGULATION COMPLIANCE Completion Date: Completion Date: Completion Date: Completion Date: XP. x./23/08 GENERAL NOTES! 1) ALL WIRE AND CONDUIT MUST BE INSTALLED IN ACCORDANCE WITH PLANS AND SPECIFICATION, AND MUST MEET ALL APPLICABLE CODES. 2) ALL WIRE AND CABLE MUST BE RATED FOR FIRE ALARM USER PER THE LATEST REVISIONS, OF THE NATIONAL ELECTRICAL CODE SECTION 760. THIS IS A POWER LIMITED FIRE ALARM SYSTEM, ALL CABLE MUST BE MARKED FPL, FPLR, OR FPLP. 3) ALL CONDUCTORS MUST TEST FREE OF GROUND BEFORE MAKING CONNECTION TO THE FIRE ALARM CONTROL PANEL. 4) TO RETAIN WARRANTEE, THE FIRE ALARM EQUIPMENT MUST BE POWERED UP UNDER THE DIRECTION OF A QUALIFIED MANUFACTURER'S TECHNICIAN. 5) THE LIFE SAFETY SYSTEM IS A COMPLETELY SUPERVISED SYSTEM. MANUFIALCTURER INC U NGSPIUGESOIN IDEVICES, WI EDCEMIT RUNST AND E OPERATION IN THE SYSTEM. MANUFACTURER SHALL NOT BE HELD RESPONSIBLE CAUSED BY THOSE CHANGES. 7) LIFE SAFETY AUDIBLE SHALL BE AUDIBLE THROUGHOUT THE SPACE AND HAVE A SOUND PRESSURE LEVEL NOT LESS THAN 15db ABOVE AMBIENT NOISE LEVEL MEASURED AT 4'-0' ABOVE FINISHED FLOOR. 8) SYSTEM SHALL BE CLASS 'B' IN CONFIGURATION. 9) LOCATE ALL PULL STATION AND HORN/ STROBE UNITS AT SPECIFIED HIGH PER NFPA 72 AND ADA SEE DETAIL. 10) SMOKE DETECTOR LOCATION ARE FOR REFERENCE ONLY AND SHALL BE INSTALLED PER NEPA 72 11) ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ROUGH—IN INSTALLATION WITH THE FIRE ALARM CONTRACTOR 12) SMOKE DETECTORS IN CEILING MUST BE LESS THAN 15' FROM A WALL AND / OR NO FURTHER THAN 30' FROM EACH OTHER. 13) NO SMOKE DETECTOR SHALL BE LOCATED CLOSER THAN 36' TO ANY AIR REGISTER OR DIFFUSER 14) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 24' TO ANY AIR REGISTER OR DIFFUSER. 15) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 36' TO ANY PART OF ANY HEAT GENERATION DEVICE (FUSE, BOILERS, WATER HEATER, ETC..) IN MECHANICAL ROOMS. 16) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 18' TO ANY PART OF LIGHT FIXTURE, 17) INITIATIONCONDUIT AND SIGNALING CIRCUITS ARE SEPARATE YET MAY BE RUN IN SAME 18) ALL CONDUCTORS SHALL BE LABELED BY ZONE AND ALL COLOR CODES SHALL MATCH 19) ALL CIRCUIT FEED AND RETURN'S SHALL BE SEPARATED BY A MINIMUM OF 1' WHEN INSTALLED VERTICALLY AND 4' WHEN INSTALLED HORIZONTALLY PER NFPA72 20) THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATION TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA. 21) METALLIC RACEWAY SHALL BE USED WHEN REQUIRED BY CODE, SPECIFICATIONS AND' CONTRACT DOCUMENTS 22) ALL RACEWAYS MUST BE FREE OF MOISTURE. 23) ALL i'IRCUIT FEED AND RETURN'S SHALL BE SEPARATED BY A MINIMUM OF 1' WHEN INSTALLED VERTICALLY 'AND 4' WHEN INSTALLED HORIZONTALLY PER NFPA72 24) REFER TO HSM FIRE DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE MOUNTING BOXES. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROPER INSTALLATION OF ALL MOUNTING BOXES 25) AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE WIRING. 26) UNRELATED (NON—FIRE) WIRING SHALL NOT BE IN THE SAME RACEWAY AS FIRE WIRING. 27) ALL CONTRACTOR FIELD WIRING MUST ENTER TOP AND/OR SIDE OF FIRE CONTROL PANEL ONLY. SEE DATA SHEET. 28) ALL FIRE WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 29) ALL WIRES SHALL BE LABELED AND TAGGED. 30) ALL WIRE SHALL MEET ALL APPLICABLE NATIONAL ELECTRICAL CODE ARTICLES FOR FIRE AND LOW VOLTAGE WIRING. 31) THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATION TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA. DEVICE LEGEND PARTS LIST MODEL MANUFACTURER DESCRIPTION MOUNTING REQUIREMENTS D9412 BOSCH FIRE ALARM PANEL EXISTING 5395 SILENT KNIGHT 3 AMP POWER SUPPLY EXISTING MT-24MCW-FR WHEELOCK HORN/STROBE 4 SQ. BOX RSS-24MCW-FR WHEELOCK STROBE 4 SQ. BOX FMM-100SATK BOSCH PULL STATION 4 SQ. BOX D253 BOSCH SMOKE DETECTOR 4 SQ. BOX D1256 BOSCH ANNUNCIATOR EXISTING hA(;N FIRE ALARM CONTROL PANEL NACP NAC PANEL — 3 AMP ANN ANNUNCIATOR SMOKE DETECTOR HORN/STROBE STROBE F PULL STATION CCETED Without Comments As Noted In Red 0 Per The Attached Letter i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do riot authorize violations of adopted stanaaras and orainances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this.acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 6I %D/0 u By:- NOTICE A completed, signed, Fire Department Pre Certificate must be pr pr to the Inspector commencement of Testing and Detection Sy` Failure of test will in a Re -inspection l termination of the test sensed )r to eptance alarm ems. esult ee and esting• TUKWILA FIRE DEPAR7-IvtEl�d� Please call: 575.4407 and give this job No. ©8-- F300 and exact address for shut' iown or restoration approval. Checked by SHEET NUMBER FA1.O 02 F N1-1 75CD /4/2 FPLR FACP NACP 16/2 FPL 16/2 FPLR;i:' N2-1 30CD 16/2 FPLR\ N2-2 75CD 01 4/2 FPLR .2 F.:PLR ..• / 4/2 FPLR N1-4 75CD N1-3 110CD • • ::• : : • • •-• N2-3 75CD /4/2 FPLR 14/2 FPLR (2)14/2 FPLR • 14/2 FPLR 16/2 FPLR\ "c7 N2-5 30CD N2-4 75CD 14/2 FPLR / 4/2 FPLR • • ••• . • •• :•• . . " :• ... .... .. .... .• .••• N1-5 30CD F 05 (2)16/2 FPLR-\ • N1-6 30CD EOL , .. . :•• •••• •.• ..... 14/2z FPLR •:• j7 N4-3 75CD 16i2 FPL N2-6 14/2 FPLR 1 75CD 16 14/2 FPLR 2 FPL N2-7 75CD EOL Al 04 4 NACP NACP N4-1 15CD 2 FPLR 1 ' •"•••::';,•V REMAiN 04 \ 1:412-PPER N4-2 15CD \-14/2 FPLR 4/2 FPLR .16/2 FPLR-'J 14/2 FPLR 22 30CD ...... •••••••••••:,....,•••••••••••.i • 14/2..FPLR •• x:••••sf.:.:• .................................... N4-4 110CD ,••.";;;;; . • DEVICE LEGEND FACP NACP ANN F FIRE ALARM CONTROL PANEL NAC PANEL - 3 AMP ANNUNCIATOR SMOKE DETECTOR HORN/STROBE STROBE PULL STATION •,, ,i •, ,.5:K.:..W.:: .... ........... .:'.::::.•,..,..V.ViI, • ...i ,. .., : : •:. :A • :, il s•••••••••“.,•••••• • HR.:Ss": :;,••• • • . , • '•,•• irkn. N / ‘$i • :•••• \s•Mis.. V., "•:.•`::, N3-4 30CD •c7 \14/2 FPLR N3-2 75CD • s. • ••• ,,,,,, ................ 14/2 FPLR C.; ......... 14/2 FPLR N3-3 75CD 14/2 FPLR • •••.: ,,,,,,,,, ::;„:•,••••••.k. ... Z.\ N4-5 110CD "-14/2 FPLR • N4-6 30CD• 16/2 FPLIN EOL , U N3-5 ss, 75CD \-14/2 FPLR N3-6 75CD EOL 0 LO C 0 Ox IX' 00 0. 4— : < N 00 Ce3 00 N 0 N 1 1 (.), 0 LLI C.0 (Ni LO , > LdW I I O•=1—' _1 in In NLd N N c•I 03 -it -41- cn FIRST FLOOR PLAN NORTH 1/8" 1'-0" 5' 10' 20' 30' PROJECT TITLE SHEET CONTENT Job No. • Checked by Date Drawn by Scale SHEET NUMBER FA2.0 r NAC 4 N4-6 30CD N4-5 110CD 14/2 14/2 FPL FPL N4-4 110CD lir 14/2 FPL N4-3 N4-2 75CD 15CD 14/2 FPL 14/2 FPL TWO LINES TO CENTRAL STATION N4-1 15CD 14/2 FPL TELCO LINE SILENT KNIGHT 3 AMP POWER SUPPLY 5395 SILENT KNIGHT 3 AMP POWER SUPPLY 5395 120 VAC RJ31X CONN BLOCK 120 VAC N3-1 N3-2 30CD 75CD 176 14/2 14/2 FPL FPL N3-3 75CD lir 14/2 FPL RJ31X CONN BLOCK ONE—LINE RISER DIAGRAM FACP BOSCH D9412 SILENT KNIGHT 3 AMP POWER SUPPLY 5395 ABOVE FACP — 120 VAC 16/2 FPL 1 16/2 FPL F 02 120 VAC N3-4 30CD N3-5 N3-6 75CD 75CD 70r lir 11111111„:„.„. 14/2 14/2 14/2 FPL FPL FPL N1-1 75CD 14/2 FPL N2-1 30CD N1-2 15CD 14/2 FPL N2-2 75CD N1-3 110CD 14/2 FPL N2-3 75CD DEVICE LEGEND FACP NACP ANN FIRE ALARM CONTROL PANEL NAC PANEL - 3 AMP ANNUNCIATOR SMOKE DETECTOR Cr HORN/STROBE STROBE PULL STATION F NAC 3 N1-4 75CD lor 14/2 FPL N2-4 75CD N1-5 N1-6 30CD 30CD 14/2 FPL N2-5 30CD NAC 1 14/2 FPL N2-6 N2-7 75CD 75CD 14/2 14/2 14/2 14/2 14/2 14/2 14/2 FPL FPL FPL FPL FPL FPL FPL 16/2 FPL F 16/2 FPL 05 F 06 NAC 2 PROJECT TITLE SHEET CONTENT Job No. Checked by Date • Drawn by Scale SHEET, NUMBER FA3.0 • \\\\oma\��\\�\\\\\. Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building FACP Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA Bosch D9412 Fire Alarm System 1 150 300 150 300 Bosch D1256 Annunciator 1 104 206 104 206 0.55 2.2 2.2 6.20 0 0 N/A 0 0 2 0 0 N/A 0 0 2 0 0 Total System Current 0 0 0 254 506 Smoke Detectors / Auxiliary Devices Quantity of Standby Hrs. Re.uired Bosch D263 Smoke Detector 2 0.08 0.12 0.16 0.24 Bosch FMM-100SATK Pull Station 4 0.55 0.55 2.2 2.2 6.20 NIA 1.86 N/A 0 0 2 N/A 0 N/A 0 0 2 N/A 0 N/A 0 0 0 0 0 0 0 0 0 0 N/A N/A 0 0 Device Totals 6 N/A N/A 2.36 2.44 Notification Appliances (list all) Quantity of Standby Hrs. Re.uired 24 N/A 5 N/A 0 Total System Alarm rnA 508.44 N/A 6.15 N/A 0 Min. NH Battery 6.20 NIA 1.86 N/A 0 MT-24MCW-FR Horn/Strobe 110cd 2 N/A 0 N/A 0 RSS-24MCW-FR Strobe 15cd 2 N/A 0 N/A 0 RSS-24MCW-FR Strobe 30cd 0 N/A 175 N/A o 0 0 NiA N/A N/A 0 Notification Appliance Totals 0 N/A N/A N/A 0 Summary Section Quantity of Standby Hrs. Re.uired 24 Alarm Sounding Minutes 5 Total System Standby rnA 256.36 Total System Alarm rnA 508.44 Total System Standby A/I-1 6.15 Total System Alarm NH 0.04 Min. NH Battery 6.20 ADD 30% FOR BATTERY DEPLETION 1.86 Required A/H Battery 8.05 A/H BATTERY PROVIDED FOR SYSTEM Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #3 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby rnA Alarm mA Silent Knight 5395 NAC Panel 1 75 175 75 175 0 0 MT-24MCW-FR Horn/Strobe 30cd 1 0 0 o 0 MT-24MCW-FR Horn/Strobe 75cd 1 0 0 0 0 MT-24MCW-FR Horn/Strobe 110cd 2 0 0 0 0 RSS-24MCW-FR Strobe 15cd 2 0 0 Total System Current 0 RSS-24MCW-FR Strobe 30cd 0 75 175 Smoke Detectors / Auxiliary Devices Quantity of MT-24MCW-FR Horn/Strobe 15cd 60 N/A 41 0 0 MT-24MCW-FR Horn/Strobe 30cd 1 N/A 63 o 0 MT-24MCW-FR Horn/Strobe 75cd 1 N/A 109 0 0 MT-24MCW-FR Horn/Strobe 110cd 2 N/A 140 0 0 RSS-24MCW-FR Strobe 15cd 2 N/A 60 0 0 RSS-24MCW-FR Strobe 30cd 0 0 0 0 0 0 0 N/A N/A 0 0 Device Totals 0 N/A N/A 0 0 Notification Appliances (list all) Quantity of MT-24MCW-FR Horn/Strobe 15cd 60 N/A 41 N/A 0 MT-24MCW-FR Horn/Strobe 30cd 1 N/A 63 N/A . 63 MT-24MCW-FR Horn/Strobe 75cd 1 N/A 109 N/A 109 MT-24MCW-FR Horn/Strobe 110cd 2 N/A 140 N/A 280 RSS-24MCW-FR Strobe 15cd 2 N/A 60 N/A 120 RSS-24MCW-FR Strobe 30cd 0 N/A 92 N/A 0 0 0 N/A N/A N/A 0 Device Totals 0 N/A N/A N/A 0 0 N/A N/A N/A 0 Notification Appliance Totals 6 6 0 N/A 572 Summary Section Quantity of Standby Hrs, Required 60 Alarm Sounding Minutes 5 Total System Standby mA 75 Total System Alarm mA 747 Total System Standby A/H 4.50 Total System Alarm A/H 0.06 Min. NH Battery 4.56 ADD 30% FOR BATTERY DEPLETION 1.37 Required NH Battery 5.93 A/H BATTERY PROVIDED FOR SYSTEM \\\\\oma \•\\ �: Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #1 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Silent Knight 5395 NAC Panel 1 75 175 75 175 0 0 MT-24MCW-FR Horn/Strobe 30cd 4 0 0 0 0 MT-24MCW-FR Horn/Strobe 75cd 7 0 0 0 0 MT-24MCW-FR Horn/Strobe 110cd 1 0 0 0 0 RSS-24MCW-FR Strobe 15cd 1 0 0 Total System Current 0 RSS-24MCW-FR Strobe 30cd 0 75 175 Smoke Detectors / Auxiliary Devices Quantity of MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 0 0 MT-24MCW-FR Horn/Strobe 30cd 4 N/A 63 0 0 MT-24MCW-FR Horn/Strobe 75cd 7 N/A 109 0 0 MT-24MCW-FR Horn/Strobe 110cd 1 N/A 140 0 0 RSS-24MCW-FR Strobe 15cd 1 N/A 60 0 0 RSS-24MCW-FR Strobe 30cd 0 0 0 0 0 0 0 N/A N/A 0 0 Device Totals 0 N/A N/A 0 0 Notification Appliances (list all) Quantity of MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 N/A 0 MT-24MCW-FR Horn/Strobe 30cd 4 N/A 63 N/A 252 MT-24MCW-FR Horn/Strobe 75cd 7 N/A 109 N/A 763 MT-24MCW-FR Horn/Strobe 110cd 1 N/A 140 N/A 140 RSS-24MCW-FR Strobe 15cd 1 N/A 60 N/A 60 RSS-24MCW-FR Strobe 30cd RSS-24MCW-FR Strobe 30cd N/A 92 N/A 0 0 0.14 N/A N/A N/A 0 0 = N/A N/A N/A 0 0 N/A N/A N/A 0 Notification Appliance Totals 13 6 0 N/A 1215 Summary Section Quantity of Standby mA Standby Hrs. Required 60 Total Device Alarm Sounding Minutes 5 Per Device Total System Standby mA 75 Alarm mA Total System Alarm mA 1390 126 Total System Standby NH 4.50 0 Total System Alarm NH 0.12 436 Min. A/H Battery 4.62 0 ADD 30% FOR BATTERY DEPLETION 1.38 0 Required NH Battery 6.00 1 NH BATTERY PROVIDED FOR SYSTEM u Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #2 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Silent Knight 5395 NAC Panel 1 75 175 75 175 41 N/A 0 MT-24MCW-FR Horn/Strobe 30cd 0 0 63 N/A 126 MT 24MCW-FR Horn/Strobe 75cd 0 0 109 N/A 436 MT-24MCW-FR Horn/Strobe 110cd 0 0 140 N/A 0 RSS-24MCW-FR Strobe 15cd 0 0 Total System Current N/A 0 RSS-24MCW-FR Strobe 30cd 75 175 Smoke Detectors / Auxiliary Devices 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Device Totals 0 0 0 Notification Appliances (list all) NACP #1 „xY MT-24MCW-FR Horn/Strobe 15cd N/A 41 N/A 0 MT-24MCW-FR Horn/Strobe 30cd 2 N/A 63 N/A 126 MT 24MCW-FR Horn/Strobe 75cd 4 NIA 109 N/A 436 MT-24MCW-FR Horn/Strobe 110cd 0.063 N/A 140 N/A 0 RSS-24MCW-FR Strobe 15cd 0.109 NYA 60 N/A 0 RSS-24MCW-FR Strobe 30cd MT-24MCW-FR Horn/Strobe 110cd N/A 92 N/A 0 0.14 N/A 0.06 N/A 0 = 0.06 N/A RSS-24MCW-FR Strobe 30cd N/A . 0 = N/A N/A 0 Notification Appliance Totals 6 0 N/A 562 x = 0 Summary Section Standby Hrs. Required 60 Alarm Sounding Minutes 5 Total System Standby mA 75 Total System Alarm mA 737 Total System Standby A/H 4.50 Total System Alarm NH 0.06 Min. NH Battery 4.56 ADD 30% FOR BATTERY DEPLETION 1.37 Required A/H Battery 5.93 NH BATTERY PROVIDED FOR SYSTEM FORT DENT OFFICE BUILDING III - UNIVERSITY OF PHOENIX Panel NACP #1 „xY 1 REVISIONS I Circuit Device Current # of Devices Current N1 MT-24MCW-FR Horn/Strobe 15cd 0.041 X = 0 MT-24MCW-FR Horn/Strobe 3ocd 0.063 X 2 = 0.126 MT-24MCW-FR Horn/Strobe 75cd 0.109 X 2 = 0.218 MT-24MCW-FR Horn/Strobe 110cd 0.14 X 1 = 0.14 RSS-24MCW-FR Strobe 15cd 0.06 X 1 = 0.06 RSS-24MCW-FR Strobe 30cd 0.092 X = 0 X = 0 x = 0 X = 0 Total Current 0.544 Panel NACP #1 Circuit Device Current I # of Devices Current N2 MT-24MCW-FR Horn/Strobe 15cd 0.041 X = 0 MT-24MCW-FR Horn/Strobe 30cd 0.063 X 2 = 0.126 MT-24MCW-FR Horn/Strobe 75cd 0.109 X 5 = 0.545 MT-24MCW-FR Horn/Strobe 110cd 0.14 X = 0 RSS-24MCW-FR Strobe 15cd 0.06 X = 0 RSS-24MCW-FR Strobe 30cd 0.092 X = 0 x = 0 X = 0 X = 0 Total Current 0.671 Panel NACP #2 Circuit Device Current # of Devices Current N3 MT-24MCW-FR Horn/Strobe 15cd 0.041 X = 0 MT-24MCW-FR Horn/Strobe 30cd 0.063 X 1 = 0.063 MT-24MCW-FR Horn/Strobe 75cd 0.109 X 1 = 0.109 MT-24MCW-FR Horn/Strobe 110cd 0.14 X 2 = 0.28 RSS-24MCW-FR Strobe 15cd 0.06 X 2 = 0.12 RSS-24MCW-FR Strobe 30cd 0.092 X = 0 x = 0 X = 0 x = 0 Total Current 0.572 Panel NACP #3 Circuit Device Current # of Devices Current N4 MT-24MCW-FR Horn/Strobe 15cd 0.041 X = 0 MT-24MCW-FR Horn/Strobe 3ocd 0.063 X 2 = 0.126 MT-24MCW-FR Horn/Strobe 75cd 0.109 X 4 = 0.436 MT-24MCW-FR Horn/Strobe 110cd 0.14 X = 0 RSS-24MCW-FR Strobe 15cd 0.06 X = 0 RSS-24MCW-FR Strobe 3ocd 0.092 X = 0 X = 0 X = 0 X = 0 Total Current ii 0.562 EOL 3.19 169 X 0.544 0.293 23.707 1000 12ga. 2 cond 1.5912 14 ga, 2 cond 3.1912 EOL 3.19 166 1000 X 0.671 0.355 23.645 12ga. 2 cond 1.5912 14 ga, 2 cond 3.1912 EOL 3.19 120 1000 X 0.572 0.219 23.781 12ga. 2 cond 1.5912 14 ga, 2 cond 3.19 i2 EOL 3.19 224 1000 X 0.562 0.402 23.598 12ga. 2 cond 1.5912 14 ga, 2 cond 3.19 0 a' tf) d COC o) D rr .< a W E N a W O f- J t� 5 W v)m N 00 O 0 N (n to tf) Lf) N N d' "t' 0 *lam a. uJ u. w 0oCI r bi - r�pJ i�l� Rai w, o z „CI I z r SHEET CONTENT f. o L1 _ Iw < o Q J _J O V Job No. Checked by;; Date Drawn by Scale SHEET NUMBER FA4.0 „xY 1 REVISIONS I s IH 3.4 CO M a 1 ` r 0 *lam a. uJ u. w 0oCI r bi - r�pJ i�l� Rai w, o z „CI I z r SHEET CONTENT f. o L1 _ Iw < o Q J _J O V Job No. Checked by;; Date Drawn by Scale SHEET NUMBER FA4.0 0 0 rn 0 J w 0 Li N c 0 0 c Y +S 0 N O cu la. oO is o- • 00 Li - /1 �m 1a se mcsj Ea5iFF o M II 4- to mar-- rn c„ E 822 I=cnox io Without Comments As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards, Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or -revisions to these drawingssafter this date will vold this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Prevention Bureau. Date"I1 ..ay: ,ItILVAILA FIRE QgP Please oat!: 575 azii give this No" 10 I OD and ficact address 'fix Own or restpratten p C ti s,,vse S Indke 6I, f. clove FA -c p q v PS . ' L11)04. vrcii4,' Ivoloi LtCt 2 0%, (ACa (4W (Ace 4ti0t c; c,,;-- LjrYgktvs • NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. MANUFACTURE MODEL DESCRIPTION SYMBOL SILENT KNIGHT 5495. POWER SUPPLY I FC -9 5 SYSTEM SENSOR P2R/SR HORN/STROBE STROBE 13 21 Ex151-(nl, CO 5 (-0 ° • 0 Dem L' A- -G O ARIL LLI-Y E0 (r\ exlei i (AL A- F I 9..e. Al. -\ o "SCOPE OMORK" INSTALLAN AUTOMATIC FIRE A , RMSYSTEM IN A y 5 n (c Ce �.. ALL WIRE TO BE I:PLR-MIN 18AWG, 16AWG FOR NAC CIRCUITS. ALL STROBES TO BE AT 80" ON BOTTOM, HORNS TO BE 'T5 DB MINIMUM THROUGHOUT. ALL PULL STATIONS AT 48" ON TOP. MONITORING VIA UL LISTED CENTER STATION. A FULL-SERVICE AGREEMENT IS IN PLACE TO ASSURE PROPER TESTING. AND MAINTENANCE PER NFPA 72 STANDARDS. ALL WORK TO BE PERFORMED IN WOF -,MAN LIKE. FASHION. INSTALLATION SHALL . MEET NFPA 72, UBC, UFC, WAC, IFC AND ANY • LOCAL AIH CODES. A FULL PRE-TEST SHALL BE COMPLETED PRIOR TO CALLING AHJ FOR FINAL ACCEPTANCE TEST. Ps OPEN WORK AREA 13'-0" CONFERENCE 202 1200IAIa TRAINING ROOM 204 NOT IN SCOPE 203 I A OFFICE 205 OFFICE 206 FEC ILIMENINEI PORIUMEMUI II KITCHEN 200 OPEN WORK AREA 201 \/\ '1-0 e5 n f9 -c 16 -112ce_ NOT IN SCOPE 0 FIRE ALARM SCALE:3/16" = 1'0" ) NORTH CONSTRUCTION LEGEND. FEC EXISTING BUILDING CORE: EXISTING 1 -HOUR RATED CORRIDOR PARTITION. EXISTING DEMISING PARTITION, NEW BIS TENANT INTERIOR PARTITION. SEE DETAIL 7/TI-1. NEW BIS 1 -HOUR RATED PARTITION. SEE DETAIL 6111-1. NEW 8/S 2'-0" WIDE X FULL -HEIGHT TEMPERED SAFETY GLASS RELITE. NEW BIS FIRE RATED 6-0" WIDE X 4'-0" HIGH PARTIAL HEIGHT TEMPERED SAFETY GLASS RELITE ASSEMBLY IN ACCORDANCE WITH ASTM E 119. EXISTING, U.N.O., FIRE EXTINGUISHER CABINET. ALIGN. CONSTRUCTION NOTES 1. ALL WALL INFILLS TO ALIGN WITH ADJACENT SURFACES ON EACH SIDE. 2. CONTRACTOR TO PROVIDE AND INSTALL BLOCKING FOR ALL DOORS, ACCESSORIES AND CABINETRY, IF REQUIRED. 3. FOR GENERAL NOTES, SEE TI -1. CONSTRUCTION KEYNOTES EXISTING 60 -MINUTE RATED CORRIDOR. 2O CONTRACTOR TO CHECK CONDITION OF INSULATION ABOVE EXISTING DEMISING PARTITION AND REPAIR AS REQUIRED TO BRING TO "LIKE NEW" CONDITION. CONTRACTOR TO RE -INS DEMOLITION KEYNOTE LOCATION. LL REMOVED WHITEBOARD PER ). VERIFY WITH TENANT EXACT 0 CONTRACTOR TO MODIFY HARDWARE OF EXISTING DOOR BY PROVIDING AND INSTALLING B/S PANIC HARDWARE. O CONTRACTOR TO PATCH OPENINGS LEFT BY REMOVAL OF CONTROL SWITCHES AND TO FINISH TO MATCH ADJACENT. O6 CONTRACTOR TO PROVIDE AND POST A SIGN INDICATING MAXIMUM OCCUPANCY OF (63) IN ROOM. EXACT LOCATION IS TO BE DETERMINED. O7 CONTRACTOR TO PROVIDE AND POST A "NOT AN EXIT" SIGN AT THIS A DOOR, DOOR SCHEDULE DOOR NUMBER TYPE OF DOOR A. NEW B/S 3'-0" WIDE X (t) 8'-0" HIGH X 1-3/4" THICK SC WOOD DOOR IN BIS WOOD FRAME. B. NEW B/S 45 -MINUTE 3'-0" WIDE X (t) 8'-0" HIGH X 1-3/4" S.C. WOOD DOOR AND METAL FRAME ASSEMBLY. HARDWARE a. B/S LATCHSET. b. B/S LATCHSET AND CLOSER. c. BIS PANIC HARDWARE. 6", UNLESS OTHERWISE NOTED NOTES: EXISTING DOOR TO REMAIN 1. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO BE LEVER -TYPE, HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO UTASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, FINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 2. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 FOUNDS (222 N), SLIDING OR FOLDING DOOR = 5.0 POUNDS (22.2 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR INA CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 3. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.5 INCH (12.7 MM) IN HEIGHT. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THIN 0.25 INCH (6.4 MM) AT DOORWAYS SHALL BE BEVELED WITH A SLOFE NOT GREATER THAN ON UNIT VERTICAL IN TWO UNITS HORIZONTAL(50-PERCENT SLOPE). FORT DENT SII 6840 FORT DENT WAY TUKWILA, WASHINGTON 98188 Fire Protection, Inc. 1730 GIBSON ROAD EVERETT, WA 98204 (425) 290-9600 o 800-6 1- 125(Phone)425-3. Fire Protection, Inc. 1730 GIS80 OAD, EV RETT, A 98 04 DRAWN BY CONT#FIREEPL*031 Mi., LI#CATS*RL 022CL' SEATTLE FIRE CE(3T,#SLrP-(-9955 N I C ET#4- #Ou r ;3::t? CFPS#147e PROPERTY OF AND ALL RIGHTS RESE9D ` FIRE PFIDIEoriON,•INC. DATE • 77 °TECri3O 0008 1 ans at dha4 CFPS® *1473 Marvin Ste planning sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441-1449 DRAWN BY: MW CHECKED BY: SN, GG JOB NO.: 08153.006 NO. REVISIONS INDICATED THUS 0 SUBMITTAL FOR REVIEW TENANT: STATE FARM INSURANCE (SECOND FLOOR) SHEET TITLE: FIRE ALARM PAID MAY 212010 TUPVVILA FIRF 0' PRI`0, OFF. STAFF ENT. 0 z w`. 0i SUPPLY CABINET CONSULTATION 7 2 sr OP #1 RECEPTION ROOM MAIN ENT. PT.'S LAV. 1 1 1 1! III AL as.s r.aun d. awns -s role In pips 11'!.7 Full flow oudr -:ign.ct 0ualiN can iron Ime, el Ioesdng edlar Sforted bort z.nings adaw for incvdauon won anh on. nus rsmw.d. 110 ,1011 7rte � .1 ULC,)1 L New Tee -Lox' Mechanical Branch Connector From CPLD AOPProved • sc. sc. 3 31ozsourp, '531: • VVAnO making in Arvnrn PROPOSED LAYOUT ( 12 P1•1 ;cAlo,f 4 E R E .iTr, i& e�Grli T 6 R RE (ocn�G r 2 v� oveLv 7©r'r+-C- Z¢ RoLiferb& llaD eL 6-4 /''Fd111 /k5° 4.4'i2- ‘514 4'/2 vrQ FI)C p&p/ F/M2,9>'tll A!L /-u reel ;AEI U. L r F.(1, 2 WASHER/ DRYER STACKED 2 1 -- 2 .r - RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS NORTH Timariemwrismearemasaas~~.........~~was7 ECCE T 4r rtYKWILA FIRE DEPARTMEN1 Please call: 575-440Z end give this job 8— a o 8 and exact address for shuts clown or restoration approve!: CRO/N FIRE PROTECTION ACTION INCORPC)FRAT`D P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 48}-7669 Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do riot authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions tv these drawings after this date will void this,acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /0-Z °� By 4 rl1' PAID OCT 252005 Tukwila Fire DENTAL OFFICE BUILDING D R. '' 7\00 Mr+ Dtni toot' �0 \ 2_10r 13, 1d1/4. fi 1-0\ i 1a/ lam, DATE: iD• I DRAWN: LM 1 SCALE: or / 122 MEM MIN JO= ME* s2a =ES 22= MOW - /c 0"DE .II= =2 C=2 2222 2E= 112= is=r111=C 2222 giftr BEN IIMIZ 1105112 V= =MI =2" pout'rt . DeTiarc-tor- cmSC- C VA LAW A55FeM+bLy, comocexe- \Auer 4'IARV PDL- 15*-: oTHEAS r 0 1 1 1 1 1 1 1 %0~ et -er- 1 6bI :s's )0)X RISER ROOM'S b"D1 emni pen me S5 t 0=10" _I �.x►a• INET R15tR NEW WLD 1 W61 w/ NEW ASS• gXTER IOR CAN copy NONCOM /5 ti ST1 dk.t N.A+4. WATER SUPPLY INFORMATION STATIC RESIDUAL FLOW 155 PSI 105 PSI 1671 GPM AT 105 PSI THIS INFORMATION WAS PROVIDED BY THE PUBUC WORKS DEPARTMENT OF THE CITY OF TUKWILA. SITE PLAN (11) 10 • 20 30 40 50 awllwok ��� rs�w ��F • aali!! ■ mrr` �� �+�kc �:�+e txa; ■ �� � �xi � ray �� � �; ��� � }w� ■ SCALE 1" = 20' Pew, aBG C.ONSTRUCTIO14 TYPE : 1 t 1-14(SPRtNKU&RP.D) OCCUPANCY GWZUPS: 8 -OFFICE. �-- r _e // YE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted i standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. 1 Additions, deletions or revisions to these drawings after 1 this date will void this acceptance and will require a resubmittal of revised drawings forsubsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 4/ y(q 7 By:t-,-/C-5-0- AO /Cs /Z TUKWILA FIRE DEPARTMEN1 Please call: 575-4407 and give this job No. Fq -2.0 T d exact address for shut' down or restoration approval. Fit E 1',Rt;tt e...0n151% s'ntc, —1115'5" So, 206 Tr, Rzer _ • 14.6.2,774 r wA , q rot r ED APPROVED BY: SCALE: /Ja DATE: �lTY op- TutCw i L6q DRAWN BY 8. P REVISED VNIVL=_-R-Srry cif. PttOEN -100 FotLr Flc 0R) '-s-v Kw t_r4 wA • DRAWING NUMBER P✓/4A/ 1 QF ly4Wy,E.inre..v!a,T.)r.o,,.T^.tr.v4;rMv^•>•r•.rf+C%r!T��:^'rJ"::.�'�.�'(Lwi:iFili:Y:4n GENERAL NOTES:. 1. ALL EXISTING LINE PIPING IS 11" 2. ALL EXISTING MAIN PIPING I5 4" 3. ALL EXISTING PENDENT SPRINKLER HEADS ON FIRST FLOOR ARE RELIABLE MOD. G XLO-ECOH 1" CHROME RECESSED, MAXIMUM SPACING I5 16 X 16, 4. MINIMUM SPACING BETWEEN XLO-ECOH SPRINKLER HEADS I5 13 FEET. 6. TIE INTO EXISTING LINES USING 1" X 1" MECH. TEE 7. TIE INTO EXISTING MAINS USING 4" X 1" MECH. TEE 8. EXISTING SPRINKLER SYSTEM I5 DESIGNED TO A DENSITY OF .15 GPM OVER 1500 SQUARE FEET 9. LINE HANGERS TO BE 3/8" QUICK BOLT OR 3/8" TOP BEAM CLAMP WITH 3/8" ROD AND HANGER RING 10. WHERE SPRINKLER HEADS ARE SPACED CLOSER THEN 13', USE RELIABLE MOD. G I" RECESSED SPRINKLERS FLOO R RI- SP\K P A\ 99 NORTH ARCHER AA!. Orrr 10' 12' 14' 16 18' 20' NOTES REVISIONS SPRINKLER SYMBOLS DATE DESCRIPTION BY ENIST• Ss P ro RE-Ltt Mob, G XI -O - EL&F} CtiCortle H,5° . Q l.oc4Te (.1si. 55P 68 }ADD ,\ S P RLL F %LI Mob . Gi ) Lo - ( coH cH2or' E 165° Re.. 3Z toe) UNIVERSITY OF PHOENIX . FORT DENT THREE 7100 FORT DENT WAY TUKWILA, WA. 98188 ARCHER CONSTRUCTION INC. 7855 S. 206TH STREET KENT, WA. 98032 PI -L* 253-872-7222 FAX* 253-872-7277 FIRE SPRINKLERS PERMIT NO. CONTRACT NO. APPROVAL CITY OF TUKWILA C.D.T. BOB POPKE SCALE NOTED DATE REVISED PLOTTED 6/4/99 2.-10F 2- .. • • • . .• -77**"... • L, „ ••• ••••••Otr.- VatiONS conditions 1.1irtt n strued as heating in sny-ra, Ativo •thri. an eidrcised ith resisect .; rut, sr *page to rropert tt Vs • tost, t in loss stilt mast, •,: , ALL EXISTING MAIN PIPING IS 4" ARCHER CONSTRUCTION INC. 7855 S. 206TH STREET KENT, WA. 98032 MMEETMIIT JUN 1 8 19 .......... ........ ..... k 25'-0' k 25'-0' 140'-0' 20'-0' k 20'-0' 25'-0 25'-0' 25'-0' 25'-0' e f \.J 1 I— Q -4 J t , 1 G A t t I tit � 1— 4-1.X 2"-t----��© -1----- 1 ; I- i i • s TU ��ft1� , per " s 4-- k 0 --� - i i — 1 i ,460 1 il++l I -1 • s\4 %� �Y r� i zx �L�• -Ill —I 2' 1 1 _ _ I apj t i ,.- s, Z E . i. 91 480 r MAINTENANCE 1 0 MEN _4Th - WOMEN v1 - 48D ; /1111 1 I 11- C I ��—{t 1 1 1I 11t +f ' 1 2' - 1 °' I HYDRAULICALLY REMOTE AREA HYDRAULICALLY CALCULATED TO DELIVER .15 GPM/SQ FT OVER 1500 SQ. FT - SYSTEM DEMAND 677.42 GPM REQ'D AT 123.43 PSI AT BASE OF RISER 1 Y �p J 11 1 0 0 1.' 8-Q -I• -+ice 11/4--1 -�1 I" :------ 1 1 I 11 ,11 1 yt } j; — — 1— f+- —1 -lb-- .--- b— Ti74 -1 1 --- 010.1 k�f .1 1 o * —8- 747— ms;µ {,Q 2-0 I I ACTS 48D� . i 1 . 1 1/ ��� 2 - `X 16-q Oe 1, i TEI+1- 2 1 r. UILDING CORRIDOR ELEVATOR x = EXISTING SPRINKLER HEAD TO REMAIN • = .KIDDED OR RELOCATED SPRINKLER HEAD Is. = EXISTING SPRINKLER HEAD TO BE RELOCATED - - = EXISTING SPRINKLER LINES = PARTIAL -HEIGHT WALLS FLOO - SLA\ (Seconc Floor) I.4 _; SCOPE OF WORK: 1 ADD /(14) AND RELOCATE (8) SPRINKLER HEADS FOR FULL -HEIGHT WALLS OF ) C7) GENERAL NOTES: I EXISTING PIPING IS 2" GRID LINES WITH 3" MAIN HANGERS TO BE BEAM CLAMPS WITH RETAINER STRAPS (TYPE '0' HANGER). I MAINTAIN EXISTING 16' x 16' SPRINKLER HEAD _SPACING. T.I. 1/8' = 1'-0' 0 ll { a - HANGER LEGEND A U HOOK COACH SCREW ROD BM. CLAMP W/ STRAP EYELET FLUSH SHELL CEILING FLANGE SIDE BEAM BRACKET SHORT CLIP ALL THREAD ROD TOGGLE NUT - POWDER DRIVEN STUD EXPANSION BOLT PIPE SPIKE STATE CERTIFICATION SPRINKLER LEGEND - at a. ornaRINKLEsrzEsit :,2z ÷ SPRAY 2 Ej 3/4 SPRAY ci ill 1- ' DRY TYPE 2 WAY EARTHQUAKE BRACE + - WAY EARTHQUAKE BRACE TEMP RATING STRucTuRE 70 CENTER LINE OF PIPE IN INCHES FITTING LEGEND 165. 284. bas 500. a. 10. g 21 118 f PLAIN END FIT FITTING APPROVAL REQUIRED SI4 GROOVED SHAPED NIPPLE CITY OF TUKWILA TSH THREADED SHAPED NIPPLE SPRINKLER HEADS USED ' SYM MANUf MODEL TYPE THREAD ORRICE SIZE SIZE NEW FINISH ESCLITCH FINISH TEMP QTY • RELIABLE 0:10-ECOH EXT COY 3 114 CHROME CHROME 165 14 QUALJT'f CONTROL BY DATE APPROVED FOR FABRICATION BY DATE GENERAL NOTES' 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND Ul. USTED OR Fif - APPROVED. 2. PIPING DIMDISIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS - SHOWN THUSLY 0-111) WHICH ARE END TO END. 3 EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH AC EPT VVitho .1" Comments As %tad In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards Acceptance is subject to errors and omissions which do not authorize violahons of adopte standards and ordinances The responsibility for the adequacy of design rests totally with the designer Additions, deletions or revisions to these drawings aft this date will void this acceptance and will require a resubmittal of revised drawings for,subsequent appro Final acceptance is subject to field test and inspect] The Tukwila Fire Prevention Bureau VICINITY MAP: N.T.S. 65 a. 9 10. NO PIPE HANGERS AND METHOD Of HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO 13. APPUCABLE EDITION. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET WO. 13. APPUCABLE EDITION JOINING Of PIPE AND MING% THREADED 1 WELDED. SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO, 13. APPUCABLE EDITION. OWNER TO PROVIDE ADEOUATE HEAT IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. AU. WIRING OF ELECTRICAL DEVICES OF REQUIRED) TO BE PROVIDED - BY OTHERS PAINTING Of PIPE 1 EQUIPMENT Of REQUIRED) TO BE PROVIDED BY OTHERS FURRING a PIPE 1 EQUIPMENT (IF REQUIRED} TO BE PROVIDED BY OTHERS DESIGN CRITERIA MAINTAIN EXISTING 16' x 16' EXTENDED COVERAGE SPACING: Please call: 575-4407 and give this job and exact address for shut- down or restoration approval. DATE PIPE NOTES REVISIONS DESCRIPTION .CONTRACT WITIt - NEW WEST CONSTRUCTION 5837 22 t ST PLACE S.E. ISSAQUAH, WA 98027 r FILE PROJECT NAME: THERAPUTIC ASSOCIATES - 7100 FORT DENT WAY TUKWILA, WA 98)68 T 10 'FIRE PROTECTION -2707 70TH AVENUE EAST -4' - fAX- (206) 922-6150 DESIGNER DAVE USIECKI 08 NO. OF - 4-4 • REVISIONS DESCRIPTION 207 209 212 0" ELEVATOR LOBBY DN. S A RS OPEN TO BELOW HANGERS ABBREVIATIONS WATERFLOW INFORMATION \ MTH FIRE SPRINKLER PLAN 1/8" = 1' SPRINKLER SYMBOLS . • BY 'IP,: BEAM CLAMP W/ Rt, i RAP • . P TRAPEZE SIDE BEAM BRACKET , EYE SOCKET - NUT & PLATE WASHER .49 KWIK-BOLT HUIP SAMMY SIDEWINDER. SAMMY SUPERSCREW COACH SCREW ROD CEILING FLANGE ic • U -HOOK SHORT ST IV\ P WALL BRACKET . • AFF BOB BOD BOJ BOP BOT CTS • FO IFOW OFOW NAS UNO 8 pF ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE RIGID COUPLING FLEXIBLE COUPLING STATIC XX PSI SYM MAKE MODEL TYPE FINISH K -FAC. THREAD ORIFICE TEMP CANOPY QTY RESIDUAL XX PSI GPM FLOWING )00(X GPM DATE & TIME . XX/XX/XX PER: CITY OF SEATTLE WATER LOCATION: GENERAL NOTES 1. EXISTING SPRINKLERS ARE RELIABLE ECQR RECESSED PENDANTS 2. MAX. DISTANCE BETWEEN SPRINKLERS IS 16" 3. ALL ARMOVERS OVER 12" SHALL BE SUPPORTED WITH A HANGER 4. SPRINKLERS SHOWN ARE IN AREAS OF REMODEL ONLY r FORT DENT III 2ND LEVEL LOCATION PLAN NTS FIRE SPRINKLERS = = EXISTING SPRINKLER TO REMAIN 2 Re = EXISTING SPRINKLER TO BE RELOCATED PLG 1 = EXISTING SPRINKLER TO BE PLUGGED 3 TOTAL SPRINKLERS NOTES: TOTAL PROJECT SPRINKLERS LI TOTAL SPRINKLERS THIS SHEET FIRE SPRINKLER DIVISION 7855 S 206TH STREET, KENT, WA 98032 PHONE 253-872-7222 FAX 253-872-7277 CCEPTE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions whichdo not authorize violations of adopted standards and ordinances. The responsibility for the adequacy, of design rests. totally with the designer. Additions, -deletions or revisions to these drawings after this date will void.this,acceptance and will require a resubmittal of revised drawings. for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 9/057 By: FILE 0'0on, hie .40 co° Co Nit ...S1 TUKWILA FIRE DEPARTMENI, Please call: 575-44R and give this job No. 0S-6)- 0•S' and exadt address for shut down 'or restoration approval.. Springy Dace STATE FARM -uav -6840 FORT DENT WAY (BLDG. #3 2ND FLR.) TUKWILA,WASH. CONTRACTOR: FOUSHEE AND ASSOCIATES PHONE: 425-746-1000 FAX:• •425-746-3737 FIRE SPRINKLER PLAN PERMIT NO: - JOB NO: AUTHORITY: CITY OF TUKWILA DESIGNER: BOB POPKE SCALE: NOTED DATE: FEBRUARY 4, 2005 REVISED / / FP 1 OF 1 PLOTTED /1 FEB - i Z005 '1;47 TUKWILA FIRE DEPARTMEN/ Please call: 575.4407 and give this jot) No. Oc:-6— /7l end exact address for shut, down or restoration approval O CCEf'TE Without Comments As Noted In Red Per The Attached Letter These plans havf: a..::_ n reviewed by The Tukwila Fire Prevention Buri Scr conformance with current city standards. Aa.;.l,f::::.. t 14 subject to errors and omissions which . i nt_q atrtr-,_,, ze violations of adopted standards a:lu I' ne responsibility for the adequacy Isley with the designer. Additic s, i , .I.. •> is n` to these drawings after this dear+:° : j rh;1Ue and will require a resubmittal l.1! rings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila FireirPrevention Bureau: Date: cl/ 105— By12W n SPRINKLER PLAN SCALE: 1/8" =1'-0" NIC ay NIC \\\ NIC A 1— f\ NIC 7 NIC NIC NIC NIC NIC NIC NIC r" R • 1-2 o° elf ,„av'f\ ti '475.1 STEEL BAR JOIST —TOP BEAM CLAMP W/ RETAINER STRAP FASTENED W/ (2) NUTS & WASHER ALL THREAD ROD ----HANGER RING HANGER A BEAM CLAMP a rA SCOPE OF WORK: F0LE 1. ADD & RELOCATE REQUIRED SPRINKLERS FOR NEE CE IING AND WALL LOCATIONS. 2. WET SYSTEMS TO BE DESIGNED PER NFPA #13 C1:11 A H RD. 3. PLAN SUBMITTAL TO AND APPROVAL BY CITY OF TUKWILA. 4. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY ARCHER CONSTRUCTION. 5. TESTING PER NFPA #13 (1999) AND CITY OF TUKWILA. 6. NEW CEILING AND WALLS DO NOT AFFECT EXISTING UPRIGHT SPRINKLER PROTECTION. CLARIFICATIONS: 1. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED AT A MINIMUM OF 40°F (BY OTHERS) IN ORDER TO PREVENT THE PIPE FROM FREEZING. EXCLUSIONS: 1. TAXES OF ANY TYPE. 2. ELECTRICAL OF ANY TYPE. 3. RELOCATION OF EXISTING LINES AND MAINS FOR WORL OF OTHER TRADES 4. STRUCTURAL VERIFICATION AND ABATEMENT OF ANY TYPE. 5. LABELING, PREP FOR & PRIMING OR PAINTING OF ANY TYPE. DESIGN CRITERIA: 1. CRITERIA BASED ON NFPA #13 (1999 EDITION) & CITY OF TUKWILA CODES. FITTER NOTES: 1. HANGERS: * ALL PIPE HANGERS TO BE BEAM CLAMP. SEE HANGER DETAIL 'A' ON SHEET FPI. 2. MAXIMUM HEAD SPACING TO BE 225 SQ. FT. 3. ALL THREADED PIPING TO BE ALLIED XL JOINED W/ THREADED FITTINGS AND COUPLINGS. SPRINKLER HEADS '`. = EXISTING RECESSED PENDENT Rio = RELOCATE EXISTING RECESSED PENDENT A0 = ADDED RECESSED PENDENT a q dy Poi trr c tl' l 139thSt ,s `PS �kb rinke l I N isS o 1. Iti1 5' •Oil lfi/t c, ,,, S 142nd St ` 58th five s N S 144th St I S 151st St 3 N S 147th St S 15019 Sl S 1501 S 152nd S1 S 15411, St 5 143rd St S 149th S1 PI 31 h o, ro •a S I @2nd PI -• o S 153rd 9 'S°4(/lCeh1N• ejvy C0 N S 143rd PI n7 no Monster Rd Sw • 101P0t Bi, * s1541n5t eS il01 ¢Un St pent- Tuk Park Sw416 ,, ar 5 S,v 7th Sty 518 Cryital Springs Fork S151stStS1Co1],31 N 3 183rd FI ' S 164th St % N S 15719 Sl S 155119 Ln 156th s1 , Tukwila 150". Soirthcenter _ - Nrestffnlif ' ' ShnpF7ngMna . SnUlbrnhtnr, VICINITY MAP SCALE: NTS Tukurila Pend 0. 41 m Baker Olvd Stondet $‘"1a Treck Dr Indust_ -n DD . nnring l,nnrr;CreS hvineld:d Park Oa kesdaic Av S)V aro, St Sly 3rd pJ Sw Sunset Blvd Shysrh cr Sr4.5, fi -a 0)qa q E 50/10114 91 Sw 120 91 Sw 16th Sl Sw 2719 St = FULL HEIGHT WALL = PARTITION WALL(NOT FULL HEIGHT) REVISIONS HANGERS ABBREVIATIONS WATERFLOW INFORMATION SPRINKLER SYMBOLS DATE DESCRIPTION BY A BEAM CLAMP W/ RETAINING STRAP AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO o ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE RIGID COUPLING FLEXIBLE COUPLING STATIC PSI SYM MAKE MODEL TYPE FINISH K -FAC. THREAD ORIFICE TEMP CANOPY QTY RESIDUAL PSI 0 RELIABLE QR, F1 RECESSED PENDENT CHROME K=5.6 155° CHROME 7 GPM FLOWING GPM DATE & TIME PER: CITY OF LOCATION: ARCHER CONSTRUCTION, INC THERA] EUTICS ASSOCIATES FORT DENT 3 7100 FORT DENT WAY TUKWILA, WA 98188 THERAPEUTICS ASSOCIATES PERMIT NO: - JOB NO: S05-80 AUTHORITY: CITY OF TUKWILA NOTES: TOTAL PROJECT SPRINKLERS = TOTAL SPRINKLERS THIS SHEET 7 FIRE SPRINKLER DIVISION 7855 S 206TH STREET, KENT, WA 98032 PHONE 253-872-7222 FAX 253-872-7277 CONTRACTOR: FOUSHEE PHONE: 425-746-1000 FAX: 425-378-2135 C I SEP - 8 2005 Tukwila Fire DESIGNER: C. GALLANT SCALE: AS NOTED DATE: SEPTEMBER 8, 2005 REVISED / / PLOTTED / FP 1 OF 1 TOKWILA FIRE DElytikrivieNT. Please coli 206-575-4 '07; ard: give this _ Fire Perrnit and exact'addr ss foe. s�ut- h { tat� down or retoga n approval: Hanger Rings / Anchors: UL Listed &. FM Approved Hanger Rods: Comply with NFPA 13 O AU Thread Rods 0. Machine Thread Rods'` Finishes. O StandardComponents FlexHead Sprinkler Drop IV-Z!-ZZIO .,;. . Corrugated stainless steel hose with stainless steel braid • available in 2', 3',4',5' & 6' Iegnths Mulls -Port Bracket • • FLE] MEAD Flexheadrtommercial Ceiling Unit T -Bar Ceiling Installation • . Model #2024,2036,2048,2060,2072 25.4 mm • Application / Description .• No: 12 Hangers are designed to support piping under ' smooth or flat concrete slab construction. They utilize an anchor that it set flush in a hole predrilled in the concrete; then expanded against the 'sides of the hole with an internal plug. NFPA 13 terms this type of fastener an ,"expansion shield". In "Automatic's" data, however, the manufac-, turer's nomenclature is used. It is called a drop-in anchor: 'there are 3 components in a basic No. 12 Hanger:: The drop-in anchor, a threaded rod end -an adjustable hanger. ring. The rod may be either all thread rod (ATR) or ma=: •chine thread rod.(MTR). All thread rod is considered to be: standard, however. As a rule, machine thread rod is pro vided only when it it a specific requirement of the job • '. specifications. • • As .an option, the Fanger may be furnished"Wi;h a spring... clip ceiling plate when 3 more finished appearance is needed in an area: NFPA Requirements / Limitations • -NFPA 13 has specific requirements and/or:limitations for the use of expansion shields (drop-in anchors) where they are installed in the vertical position. The standard reads:.:. . /n conciete having' gravel .or crushed stone 'aggregate; expansion shields 'nay be used to the '. vertical., position tb support pipe 4'" or leis. In die meter ' Por the.support of pipes 5" and larger, expansion shields if used in thevertical position shall alternate with hangers connected directly' to the structural members such es trusses• and girders, or to the sides of concrete beams In the absence of convenient • ' structural members, pipes 5" and 'larger may be sup-.• ported. entirely by expansion shields /n the.Fertrca/ position, tut spaced pot More than ' 10 ft t3 mJ. apart. Expansion shield* shall not be used in ceilings of gypsum or similar softmaterial.. ln, cinder concrete,: expansion shields shall not be used e.'cept on branch• dines where they shall alternate with through bolts of . hangers attached to beams . . Design per NFPA 13, Ordinary Hazard Group All materials to be new, UL. listed, arid F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any. other means All .heads to be at least6' apart • 2 — Add Reliable Model GFR VELO-ECOH Recessed Pendents 165° 3A x3/4 (k factor = 14) • 1=- Relocate Reliable Model GFR VELO-ECOH Recessed Pendents 165° 3/4 x3/4 (k factor =14) • E =Existing no change FIRE PROTECTION INGORPORATEQ:•. ; ..: P.O. BOX 12113 • . • MILL CREEK, • WASiINGTON 98082=0113 Piet._ (42)481-7889, :_:; :•" ; :;. 203 204 206 202 208 021 Mil 1111111 !max 1111111111111 7 DN N Alii" IE� minnum REFLECTED CEILING PLAN. SCALE: 1/8" =1'-0" 0 5' 10' 20' 30' NORTH 0 O1111 H MI III I :s • 210 4) NMS1.___ 1,1,ii 11211 Ohl MEM 1 FIN I Aot II eE 1 oR RIME ilall �l 11111E1M11111011 IISROW 1,111 El WI 1 I 1.........,,J1111111111.L.--111 111111•11111111-10 I 215 ILS 00 )3 Design per NFPA 13, bight Hazard - Offices All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 10 —. Add Tyco Model TY5237 Extended Coverage 155° Pendents 3/4 x 3/4 o 6 — Add Tyco Model TY5237 Extended Coverage 155° Pend ents 3/4 x 3/4 (these heads match existing) Clip Hangers ■ Hanger Rings:, UL Listed & FM Approved • Hanger Rods / Fasteners: Comply with NFPA 13 O All Thread Rods 0 Machine Thread Rods ■ Finishes: O Standard Components 0 All Galvanized Cgmponents Components 1. Clip (Ceiling Flange) 2. Hex Nut 3. Wood Screw 4. Hanger Rod 5. Adjustable Hanger Ring Application / Description No. 5 Hangers are designed to support small piping from smooth level wood planking that has a thickness sufficient to receive the required fasteners. The hanger is secured to the planking by means of a clip (ceiling flange or hanger flange) that is provided with a standard thread i r the rod and holes for 2 wood screws. To prevent possibl loosening of the rod due to vibration, the hanger is further secured by a hex nut tightened against the clip. There are 6 components in a basic No. 5 Hanger: The clip, 2 wood screws, a hanger rod and locking hex nut, and an adjustable hanger ring. The rod may be either all thread rod (ATR) or machine thread rod (MTR). All thread rod is considered to be standard, however. As a rule, machine thread rod is provided only when it is a specific require- ment of the job specifications. No. 5 Hangers may alsobe' used with' other types of construction of adequate strength when provided with • suitable fasteners — subject to the approval of the authority having jurisdiction (AHJ). Deviations from standard fas- teners are to be clearly indicated on the plan by detail or in a hanger note (see Hanger Codes / Plan Designations). NFPA Requirements / Limitations NFPA 13 permits the use of 2 screw ceiling flanges only for pipe sizes up to 2" and it calls for the use of screws having dimensions not less than those of No. 18 x 1'/s" wood screws. Drive screws and nails are not acceptable fasteners and wood screws are not to be driven. El Without Comments As Noted in Red i Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau fco- iformance with current City rt? naards. •Accept,:An::.:' k 3ublect to errors and • omissions which do i lc, r;, itnorize violations of adopted i:,:nciards and ordirsasice5. The: responsibility for the Ae quacy of design 1•e. tl,.3 .;;Totzigy with the designer. Additions, deletions i-evlsions to these drawings after this date will void t r ;:c;eptanc and will require a resubmittal of n .visi ,r drawings tri :. • sulasequent approval. Final acceptant E ! .i:Tuble(fir c; st and Inspection by The Tukwila Fire P ',,;.•;<-,•tic, : : Date: i i -1 . -/ CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 TUKWILA 17.18 )E.P,,;Rti 1 MEMT ','C ?i5 -`4O7, and gj e this FIr Peril t Na. /(-s g aiid.exacc aCF u oss. for shut down or.ty!stomUon.approyal. 1NASKINO."ON STXTE CERTIFICATE OF COMPETENCY 1 • FIRE PROTECTION SPRINKLER SYSTEMS • 1 John J. Abet . .. . • 97600591-cG Level 3 i n t=ire Protection, Inc. • •• ; . tura • el , �r1• • 121s1no. Therapeutic Associates FORT DENT III DATE: DRAWN: SCALE; WI.A FINE. 7100 FORT DENT WAYZ2a €a TUKWILA, WASHINGTON 98168 -UI 0 EXISTING T u (2) STORY OFFICE BUILDING AREA OF WORK (± 2,888 SQ, FT) OCCUPANT LOAD CALCULATION 7377,4 51.;17 S JUARf Fr.,C-A• 11..: P•i.fi lr r',:!;•.c:.NTS I,1;,•.1;Fk.rs: PRI:01? FORT DENT PARK ItOM haa alai as EXISTING OFF ICE E 1JlLE)IN FORT DENT III 7100 FORT DENT WAY E, I STING OFFICE BUILDING 1 'PL NTS Mt NMI • Mil PAN Ilat RS RN 444 CO;.=.5.::4 PIC *1 CO l 1 Nle.' -t.,2 Uti ) Djc_ c.)) \-0 E� `-) U.r\cAq.n 1.00 Ec) • \. ` t `\ ` \ ,`\ '\ \, \'\ \ \ \ \ \ \\ \ • t` \ t � SC.w(ik4Yn1 �'.• i "�� ;I t 1 i 1 \, \ ,�.,% ���� ik I mak© `�• \� ,�: ria �T�,_o;, uuu,'1u�111u f�'�."u �0/n1 IUN �� \� -�': � . dei a �. ' � !!!E ,u y -. \ ' • anfill111111111 ' - TIMM WiTrWr I 11.''' -..,,' MI NMI II 1 ;.741N11111......,,311 nommi' mull r 11 4 REFELECTED CEILING PLAN SCALE: 118" = 11-0" 0 5' 10' fr\ 20' • 30' NORTH t 7 • 1 SWi 'YY � b.4::413„G..� p Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The 'Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptar;ce is subject to (store and omissions which do not. ak,khoriZe violation, of adopted .xtandards and ordinances. The responsibilli:y for the adequacy of design rests totally with the designer. Additions, deletions or revisions S to these drawings after this date wiHvoev ised drawingsthis e and will require resubmittal offor sub��eguer approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau, Date: / _"� 1— ( 7 By: TUKWILA FIRE DEPARTMENT Near; r:: Iso "°c5-575-'1 07 and give this Fire Permit No and exact a d'. ,ss for shut- down hutdown or reztorWon approval, SCOPE OF WORK FORT DENT III 7100 FORT DENT WAY TUKWILA, WASHINGTON 98168 TENANT IMPROVEMENT TO THE SOUTH WEST PART OF THE FIRST FLOOR FOR OFFICE USE TO INCLUDE: • DEMOLITION OF PARTITIONS AND DOORS - • -CONSTRUCTION OF PARTITIONS AND DOORS - • • CONSTRUCTION OF CASEWORK • NEW PAINT AND FLOORING IN AREAS OF SUITE • INSTALLATION OF NEV./ AND RELOCATED LIGHT FIXTURES • NO STRUCTURAL WORK • NO ALTERATIONS OF CORE, AREA OF SUITE: ±. 2,886 SQ,FT• AREA OF FLOOR: ± 20,C ti SCS. FT. OCCUPANCY TYPE: B, OFFICE CONSTRUCTION TYPE: V -B, SPRINKLERED APPLICABLE CODES: 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 NATIONAL E_EC1 RICAI. CODE ICC/ANSI 117,1 • ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2015 WASHINGTON STATE ENERGY CODE (WSEC). WAC 51-11 WASHINGTON INDOOR AIR QUALITY CODE ASSESSOR'S PARCEL 11; 29549M440 I1 p1y"°°M4p +r r "Y ....... m C�P26IF GA E O�afd Sjq'y"`+,w w,,,n �'. W FIRS FRC1g�CT10N SPRINKLER a ErENCY A Lewis azaNatLca srsrE� a At +� I'�:rers g 2800.0691"C Level3 it1 a First ere ease Fire Protection, L. L. C. Fife$ ' FCJe. - - a It sari mum ciao% un en At W a Ri i ase 4 i3 xry�rrsk I--30._ e -� P PAID JAN 30 2017 -WWI FIRE cc $3ot)' FIRST DEFENSE FIRE PROTECTION LSC SPRINKLERS BEAT FIREMEN TO THE BLAZE 10212 215th AVE SE SNOHOMISH, WA 98290 PROJECT ADDRESS vz_c u (c, SCALE NOTED CITY TITLE FIRE SPRINKLER PLAN PHONE (360) 794-9479 LIC# 602-250-698 DWG # MECHANICAL, PLUMBING, FIRE PROTECTION & LIFE SAFETY NOTES NTS 6 VICINITY MAP NA SITE PLAN NA 7::\E-1)( I I MFG. ESC. MODEL FINISH ORIFICE ��••.�_�SPRINKLER (`'tc x ri-L L,-,` ' - :IS ., t It ` :,' •l{, 5�� -- .,:Java 1 •+`t • ✓' --_.-- ____ —_—_ t_..., ..,, :;fit; �R p�y�.y ...: ; . - i. '+t:'S': '} :'. ���� _ _ Til` 2• >/,Y,:Y9 fir::R ..5,, %: , ;ri= : ", •y' ::±�. �..'; •.,�'2z:'�i'�.J' .1+ ,� :� �4y %%/{, `}i✓;i tri f'' ";{;:Y fif.,i..;✓f ,•,.• .�'y: �' n,o•`::ky5�?� 4y13 SY`Y^+ r`. r:r'ri'}=,'r.•'�r.:6`'•'r�'ri,. �v:;.;:.„'.>,:1;2.- :.•.;.:..,�^:...<Yi:'/.rr'y;'v'.rs. ' ir — ?,.! .•,EX'Js•`3�G,:. !?' fr :,Sri fr�,i: �.c� e;:'n+St. ryi'" ,', pj�.'.;Ji'a''.'/ r`� / ` `-5 r� ?...Yn( .;r`,•,-;ftY3':Y .`•y f;' . f7%'%4 ' •;..%a ,cr,.t.J t' jT •l..:u{ 4: ,<+' }..�, �, + � �"j,�,1'c`'t'4�;3)s;'�; J rY,:� ,/, .i:�.+ :<V ;i;'s � � % g"f'.'�; �7 r"`"'�v:S+r r ,^,;::';>,i�l>�y: )'.C' 3x, y.5„ J:'L,:r;.iQ:::.t.. �,� fyjs.>.r,�;f!N %`'. "r��°`'rrf5, r `%i; / f'= 5''"7!/'.•''•'. Y,'', 1."<;n'r,`'r.'<l: . _._ _ N---_ -- ,./ • {'- v sftl �•' /s. q4; -l+J/ •; i' rg %".�: •jUw is •',':'fix1 II _.... } • £.f�•;:l�:.3't���Wc,Yny.�•';:. �T,'.•i�,.CyG'•6 �'�J<4n63++4tirST;�YfI ''` "v',✓,/%/'p ?:x> p2r,•IN /.,.",i?))':'-- fr 1; •/i iftgyY' '. +%a: f�y.,-C•';s'nL;.V.A'�Ui,-.EP{{��.,• v y/ f ` '<k 'f f~!, ; i^% % S �.'{,m`+ yy J s{'%."..''' , .:t 1h�+�: 'vii r'>r d' ; <;%,'•l.,L.•+•,r.. 3�✓.- %•,/i' i.�yy �� 'dj N S;j, ''' \ /,{r' f `;.� • 1 ���y �'::,• !' y+r J;y'. '•Ai,_',.:5• , ?''Gr'.'.,ys fi�'fii',si-•,.,• .i<'Sj% j./r1. y.5'•' �J/!!'• iir;.a.r'' _ 1,.,',...111110011.11,.,gym io ,wxcaa7g+�,%s: J,,.�/% .; <. 11111111111111111101�� C` �L`�e �S 150 •r REFLECTED CEILING PLAN SCALE: 1 /8" =1'-0" 0 1�= tZ�loGnT�. 5' 10' 20' 30' HEAD COUNT TYPE K. MFG. ESC. MODEL FINISH ORIFICE ��••.�_�SPRINKLER (`'tc x ri-L L,-,` ' - :IS ., ,tTOTAL SPRINKLERS THIS DRAWING NORTH 2 4;; © Without Comments As Noted in Red Per The Attached Letter These pians have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not aI.rthorize violations of adopted :a'ndards and ordinance The responsibility for the -,dequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance 15 subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /) -I> -r ) By. c(1 TLF CI SQA FERE DEPARTMENT Please �•: fiJ ° :r -5M-4 :07 and Ow, this F; ar Permit No. /-7 _ S- _ (7�nd exact address for shut- down hutdown or restorOn approval. SCOPE OF WORK: TENANT IMPROVEMENT TO SUITE 225 OF AN EXISTING 2 -STORY OFFICE BUILDING FOR OFFICE USE TO INCLUDE • DEMOLITION OF INTERIOR PARTITIONS, DOOR & RELITE • CONSTRUCTION OF INTERIOR PARTITIONS, DOORS, RELITES & CASEWORK • NEW PAINT AND FLOORING IN AREAS OF SUITE • INSTALLATION OF RELOCATED LIGHT FIXTURES SITE ADDRESS: PARCEL NUMBER: LEGAL DESCRIPTION: ZONING: FORT DENT III 7100 FORT DENT WAY, SUITE 225, TUKWILA, WA 98188 295490-0440 GUNDRAKERS INTERURBAN ADD PARCEL 2 LESS GEG MOST WLY CORNER OF PARCEL 1 TH N 63-35-49 E 237.32 FT TH S 26-24-11 E 227.32 FT TO COMMON COR BTW PARCELS 1 & 2 TH N 63-35-49 E 252.25 FT TH N 26-24-11 W 77.65 FT TH N 56-15-11 W 234.09 FT TH N 31-12-43 W 82.39 FT TO INTSN WITH NWLY LN OF PARCEL 2 TH S 58-47-17 E 102.77 FT TH S 55-39-53 W 63.16 FT TH S 48-39-58 W 55.63 FT TH S 39-21-15 W 88.24 FT TH S 30-04-58 W 85.21 FT TO MOST WLY COR OF PARCEL 2 TH S 37-36-40 E 20.92 FT TO POB - OF CITY OF TUKWILA SHORT PLAT NO 79 -7 -SS RECORDING NO 7908210370 SD SHORT PLAT BEING A POR OF GUNDAKERS INTERURBAN ADD IN SW 1/4 OF SEC 24-23-04 --- AS PER CITY OF TUKWILA BDRY LINE ADJ NO 90-2-BLA RECORDING NO 9008151101 PLAT BLOCK: PLAT LOT: POR RCM TYPE OF CONSTRUCTION: V -B, FUL' Y SPRINKL ERED- OCCUPANCY: GROUP B (OFFICE) AREA OF FLOOR (SUITE): ± 1,938 SF APPLICABLE CODES: TENANT BUILDING REPRESENTATIVE: ARCHITECT: WASHINGTON STATE CERTIFICATE OP COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL PLUMBING CODE (IPC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 WASHINGTON STATE ENERGY CODE (WSEC) 2015 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2014 NATIONAL ELECTRICAL CODE (NEC) 2009 ICC / ANSI A117.1 - ACCESSIBLE AND USABLE BUILDINGS & FACILITIES WASHINGTON INDOOR AIR QUALITY CODE WOOD-RICHARDSON & CO., P.S. 7100 FORT DENT WAY, SUITE 280, TUKWILA, WA 98188 PHONE: (206) 246-2520 EMAIL: SHARI@WRC-CPA.COM CONTACT: SHARI WOOD-RICHARDSON & STEFAN RICHARDSON JCR DEVELOPMENT COMPANY 2835 82ND AVENUE SE, SUITE S1, MERCER ISLAND, WA 98040 PHONE: (206) 267-6060 EMAIL: RebeccaDavidson@jcrdevco.com CONTACT: REBECCA DAVIDSON NELSON 1200 5TH AVENUE, SUITE 1300, SEATTLE, WA 98101 PHONE: (206) 408-8500 EMAIL: MEvans@nelsononline.com CONTACTS: MARK EVANS PLAN NORTH SCALE FIRST DEFENSE FIRE SPRINKLERS BEAT FIREME 10212 215th AVE SE SNOHOMISH, WA 98290 PROJECT h Wf^ j i�w(! y pr,gZ c ADDRESS / 1 -b -1- CITY .-TU �--�-�a t. t/, 186 TITLE .. FIRE SPINKLER PLAN III 1Naa .and AVS} NOV 2.3 2017 TUKWILA FIRE cc 3'' R O TECTION LLC TO THE BLAZE PHONE (360) 791-9479 LIC{/ 602-250-698 BYAY11,1 Lr' l CAD FILE DWG fl FP -1 Ntfr IN CANTiq_kG"\-- ;JEW fro -z. g.6m6ve- r Og.op 71 Zi. ---)4151' WAD kee-A-rrokl 54(1sT 014.4E04-LIJE AAM -ovr1.1z- (.5 e -e. RAO) c81.-.5° epiLikiG iz.&4_0c.,4 Tao PEW, 14 -EAP 1Yr Owe, 4P -A -D _ - • 11 i` • • • • -• r. i/ _;•••-11 (-1". - " I 4 t -S" ° 34-Sni t S11 • , 1 hit —0-7.1 ..72'6•XlSTA • • N Or IN Colo -MALT itt.•••••• ••••••••11: 1) • TT L. . goTAT5 131KANickk GIMC- {80° . - - • • 22. .11\ r -)Ls -r• • .tte 1,4" 22 0" 7740 ROTPriE. /..1i9 ibo° .},10T 1.1 NV -10 C,o10-t-RAcr Nor IN Cow c -r It - 3. )1' NUT IN GAM. 1A(.7. Li NOT _ cototm-r _ _ ..11•1 Ct>NTRIbt-c..7 NOT Cb1.11-RACT 4—i," TRU `434._A-41;0602 1,1 21..511 311mAto gOOF "C„Ic 11 DETAIL- A s. 91- Q AFF ---e ye.= FLODR FIRS 5P_R_INKLER D_Arls NoR1-4-1 kfiftc 3 /1••••••1. .1••0 Nalmmtacedat• ••••••• 18 2111 To 7-0P or- Pt ek. 4 ic 1C -s" 130r. OF gi Uj Toe klcir h3 Ce. KIT KlAc,1- RAT n ;R0,1-41". LIN V.X‘ST1 NG HEADS 27C) .1.. . 0-8,-- • sTuPY room. Al . gl C*4 _•- 'NI 0 /Imo la : -; ciir.,-.- .....-- 1 -S-Tt-IDY RotA, 1 —A 7=-7'422-4- = lV0C.IME7 2" ---- ..- - • C--.41 Tr.! cc's" 1 o-74--1/1. A 711 11 \jpcjKaat S otommosomarturrott. GCNCRAL. No-rz5 -a/ ALLEXIsTING ite-AbS 0 L -co 'RGL I AEI -G. MOD. )(I-0 ci..,ebtAg R.ec...essgr). MAX. SFC -t, IS IV )4-1 to I. - - MINIMUM 'A( -l1-3' 'etirvicEt.) SP12101cLeR HEADS 1 S IS: FeET; e..X1ST It 1(7 "...z.i4:113r.A-s-k Ys Ill IS DeSI‘Net:. fik TDeVIS ITY OP; _ ttS PitA Okit-31 !i•("0 SCIOW F•• eT. 1.)5 .1-1410,..L'R S., 10 3/g" v.)? AA C.I--rk IA? OM' :re la 01) I I (t2z---77i 6111:A -P) CD AUL /•.1v-/ . PIP/OC--:7 -r' FIP1V41 15 0 li-Cag'L Al3DVE FM)1511-- FLCOR • *I -1 = ,4„ Io ' ILII1/ 0 it VOCI RoOtA7 6 HEAD Coo t,,,rr war -eA e, IS1/5-vo SYm, OA l'Pr 100 ADD :NEW R ELI ABLq MOD. G LD EGON CMR.olvIG t--Ncv -rQ7?k-r—, 77141 Pt-A,c.J. 1111111,010103111110.er .E.XISTIOG CEILING GR,I'D AT 0 omments A Note In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not -authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletio isions to these drawings after ptance and will require a resubmittal of rev i ings forsubsequent approval. Final acceptance is subject to field test and inspection by ;The Tukwila Fire Prevention Bureau. Date:7/7-4/9 By: TUKWILA FIRE DEPAri fiN1 Please call: 575-4407 and give this job No. and exact address for shut. down or restoration approval. r AH 6K CONSTRocrio0 INC . 7855 So. 7.0 TH ST Kw,rr, WA , Cf032- .............. Pttope. -;f. 53- 872 P;72 - 9177 SCALE: y 1 0 DATE : j1,) L 9 APPROVED BY: C.-ITY or- TOicut..44 DRAWN BY self,,E,-1-T REVISED UN)11MR SIT NI OE VI-10etsitA `j !OD FtigT Dr. -11" Wy TO•Kwit..14, wA. 1818R 59q- 6`1 211' F 'FIRE sPRtwsLeR131-AoS DRAWING NUMBER i oF � :••..,C^.�c11Y3Li.]_'S..'.tLCltrtt[i.13i.C1Y2CtlM.slyluCA. e.a."ammwa (B) 8 f 1 1 comm 1 =mu 1 ummell AREA OF WORK 0111110101 I 1101010 1 01111101 I 1101011101 I ==1111 I 1=10011 1 0=1 I 0011=11 I 11111112111 I 01=101 I 10111=1 I 00011 I I 11101801 1 110000101 I I =MEI I 111110001 1 I - NEW MAIN RUNNER 1 WM= I 1111=1011 1 01=0011 I 4'- 1 2x MECH TEE EXISTING WALL NEW B/S CEILING GRID & TILE. NOT IN CONTRACT FL TUKWILA FIRE DEPARTMENT Please call: 575.4407 and give this job No. C) Z S and exact address for shut, clown or restoration approval. nVdA IPA11 Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire ; .'Tevention Bureau for conformance with current city andards. Acceptance is subject to errors and . omissions which do not authorize violations of adopted • standards and ordinances. The responsibility for the aquf drests With . Additionsdeacy , odeletionsesign or revisionstataily to thesethe drawingsdesignerafter ' this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by ,11,1e Tukwila Fire Prevention Bureau. I bi �5 (t 2 By: 1 Date: '� c�alJ � —S 1a F -tl TBE EXISTING GIRDER I. EXISTING 2" BRANCH LIN 9 N.I.C. 1 ;1-MECH 2171- 4-OTB4 j 1 EXISTING 14_ EXISTING LIN AREA OF WORK 2AT _.. 2-0 _... xZ.3 1 ■jj' APEZ 4-6 1-OTBE c7 0I PI(~/) )IV) XIO - XIO W W I 111=011 I I I I 0 F=IN PIw xl� >< W W — -2x7-3 TRAPEZ 0 0 0 0 z)- z1- z)- NI� -, I-) ,NIT WI WI WI I i=1 1 CM= 1 =100 1 OEMS I i1 0 z ,— w WI ® I 00101011 C7 C� 0 Z ►— z r— z 1- to 1= V) T= N Ln v) cnlo N wI 0 cel LA SIV . 1.=N. v V)10 NIO —3 X X WI WI \ I 1110101 1 101010100. MIES 1 r"""."1 1 MEM I =MI I MN= I NOT CONTRACT EXISTING ELEVATOR LOBBY 2" BRANCH LINE I _ EXISTING GIRDER U1STINL. rBRANCH 2 BRANCH LINEI OPEN TO BELOW EXISTING EXISTING EXISTING GIRDER 2" BRANCH LINE I 2ND FLOOR PARTIAL PIPING PLAN SCALE 1/8" = 1'-0" E 0 EXISTING PENDENT LOCATION 4 P 0 PLUG EXISTING PENDENT HEAD ' 36 R ® RELOCATE EXISTING PENDENT HEAD 13 A ® ADD NEW PENDENT (RELIABLE MOD. G., XLO-ECOH RECESSED CHROME PENDENT, 3/4", 165') (49) TOTAL RELOCATED & ADDED HEADS 8) FOLDIN 1 ==a 1 = 1 mom 1 eanso 1 row mum 1 ism 1 sumo 1 mom I NOTES: 1. ALL HANGERS & PIPING TO BE INSTALLED PER NFPA 13. 2. ARMOVERS OVER ' -0 TO UPPORTED PER NFPA 13. 3. LOCATE HEADS 1-0 x 1-0 IN SUSP. CEILING TILES. 4. ALL EXISTING' PENDENT HEADS ON SECOND FLOOR ARE RELIABLE MOD 'G' XLO—ECOH 3/4" CHROME RECESSED. (MAX SPACING 16'x16') 5. ALL NEW SPRINKLER HEADS .TO MATCH EXISTING. 6. EXISTING SPRINKLER SYSTEM IS DESIGNED TO A DENSITY OF .15 GPM OVER 1500 SOFT. 7. HANGERS FOR'!:ARMOVERS TO BE 3/8" C—CLAMP W/ RETAINING STRA", ROD & RING. UNLESS OTHERWISE NOTED. 8. ALL NEW PIPING TO BE BLT. 9. ALL PIPE CUT.- DIMENSIONS ARE TOE UNLESS OTHERWISE NOTED. PARTITION NEW MAIN 225 RUNNER MB I 0011= I 0 16) 4'-O" 1111=11=II I 1110109181 I MIES I I • irmamodi --..- 1 p 1 ABBREVIATION HANGERS REVISICNS SPRINKLER SYMBOLS AFF = ABOVE FINISH FLOOR A.S. = AUTOMATIC SPRINKLER BOD = BOTTOM OF DECK BOP = BOTTOM OF PURLIN CC = CENTER TO CENTER EC = END TO CENTER TOS = TOP OF STEEL O = HYDRALIC NODE POINT #1 - "t' LTI" W10 POWDER ACTUATED FASTENER, f D COUP., ROD & RING #2 - C CLAMP, RETAINER STRAP, ROD Sc RING #3 - VI LL BRACKET, ROD & RING #4 - 'LING FLANGE, ROD & RING #5 - DATE DESCR1PT.'ON BY * * * TOTAL SPRINKLERS ARCHER CONSTRUCTION 7855 SOUTH 206TH STREET KENT, WA 98032 PH. (253) 872-7222 FAX. ::.(253) 872-727.7 STAT- FARM 7100 FORT DENT WAY TUKWILA, WA 98188 _CONTRACTOR: .FO.USHE ...ram OCT 22 2002 35 SPRINKLER PI 'ING PLAN PERMIT NO. CONTRACT NO. _02-70 APPROVAL CITY OF 1 UKWILA C.D.T. B. IOFFER SCALE 1/8" 1'-0" DATE 1016/02 REVISED PLOTTED FP1(f1 I , ; • NOTE: EXIST CEILINGS ARE 8'-5" SUSPENDED CEILINGS WITH TEGULAR TILE. EXISTING PIPE IS APPROXIMATELY 18" ABOVE THE CEILINGS. IT IS APPROX 37" FROM CEILINGS TO BOTTOM OF STEEL BAR JOISTS. IT IS APPROX 57" FROM CEILINGS TO BOTTOM OF CONCRETE DECK ABOVE. EXISTING rr:t.ING GRD SYSTEM r0 REMAIN / FW'' / , +fir l / / Min -1'1'17F f- / / / • , , 12i1� % `// // / // / / / / R_ RR E. E • 1 1-8 L. R E /' _ /1L/.. /0/ E / Q av 00 0 JAN /OR —7 0 4" WET SPRINKLER RISER 155 PSI ON GAUGE„_ L 23 1-2 R E O IIIHilIH ui E EX!r111\10 i 11R, RAI El.) (1:(E?R IIJ(•:{Il is NO WORK 115 n 11 u1 A • E p� —J>�1 lr8�-� -- —11.-%_ I�1:3� r 3-10 n 11 No WORK • NORTH ITU 1;;; f ,a 1..i1 i?i 1 SCOPE OF WORK: 1. ADD & RELOCATE REQUIRED SPRINKLERS FOR NEW WALL LOCATIONS. 2. EXIST HEADS ARE STANDARD RESPONSE & NEW HEADS WILL MATCH (NON "QR"). 3. WET SYSTEMS TO BE DESIGNED PER 1-1FPA #13 ORDINARY HAZARD. 4. PLAN SUBMITTAL TO AND APPROVAL BY CITY OF TUKWILA: 5. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY ARCHER CONSTRUCTION. • CLARIFICATIONS: 1. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED AT A MINIMUM OF 40°F (BY OTHERS) IN ORDER TO PREVENT THE PIPE FROM FREEZING. EXCLUSIONS: 1. TAXES & ELECTRICAL OF ANY TYPE. 2. HEADS IN CENTER -LINE OF CEILING TILES (EXIST ARE NOT). 3. STRUCTURAL VERIFICATION AND ABATEMENT OF ANY TYPE. 4. RELOCATION OF EXISTING PIPE FOR NEW WORK OF OTHER TRADES. FITTER NOTES: 1 HANGERS: *ALC PIPE HANGERS TO BE HILTI HDI -P OR A TOP BM CLAMP & RETAINING STRAP. 2. MAXIMUM HEAD SPACING TO BE 256 SQ. FT. 3. ALL THREADED PIPING TO BE ALLIED XL JOINED W/ THREADED FITTINGS AND COUPLINGS. r: Xt $11.130.1:'1:-1.(f 1( SY1316I I ,') E EUtITlC;r11_. • E; :15111',!(. 1 HR. 10,1!'..l.) C('. FU 10 F;f:fil/,lN UNALTERED wJ • 0 CE 1- ; � �:�� \ \ \\ FORT DENT III 7100 FORT DENT WAY EXISTING OFFICE BUILDING FORT DENT III 7100 FORT DENT WAY EXISTING OFFICE BUILDING LATC 1-4E tjrka_ TELL 1ST FLOOR REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0" 0 2 4 8 16 -SCALE IN FEET ALL C.r0i)iC,'). FIT 1'_ i-\L_CC 5 1 ��l�C ._CL.14 Liu RLAL'.l-C. VLX 1 onC Li -k PAIL. . 1 tD)'\ \� ‘1.1) LLr E , i e_c) L} t = (tJ 1 77,51 ik 7_1 -�—�... Wit. i 4• •`�- .yam Te t c n `Without tOniments C]Ps Noted in Red Per the Attached Letter These pians.have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do rot authorize violations of adopted standards and .ordinances, The responsibility for the adequacy of deSign r�: ,t totally with the designer. Additions, deletion :; �F:visiorls to these drawings after this date will void this +-~r:eptance and will require a 4resubmittai of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: 5-- �-i - c By: .J "` St TUKWILA FIRS DEPARTMENT Please call 206-575-407 and give this Fire Permit Noe and exact address for she down or rem approvj9 v SCOPE OF WORK: SITE ADDRESS: PARCEL NUMBER: LEGAL DESCRIPTION: ZONING: rD 9NIG1If19 III INDa 1210d TENANT IMPROVEMENT TO THE SOUTHEAST PORTION OF THE FIRS' FLOOR FOR OFFICE USE TO INCLUDE: • DEMOLITION OF PARTITIONS AND DOORS • CONSTRUCTION OF PARTITIONS AND DOORS • CONSTRUCTION OF CASEWORK • NEW PAINT AND FLOORING IN SUITE • INSTALLATION OF NEW AND RELOCATED LIGHT FIXTURES • NO STRUCTURAL WORK NO ALTERATION OF CORE 7100 FORT DENT WAY TUKWILA, WA 98168 295490-0440 GUNDRAKERS INTERURBAN ADD PARCEL 2 LESS GEG MOST WLY CORNER OF PARCEL 1 TH N 63-35-49 E 237.32FT TH S 26-24-11 E 227.32FT TO COMMON COR BTW PARCELS 1 & 2 TH N 63-35-49 E 252.25 FT TH N 26-24-11 W 77.65 FT TH N 56-15-11 W 234.09 FT TH N 31-12-43 W 82.39 FT TO INTSN WITH NWLY LN OF PARCEL 2 TH S 58-47-17 E 102,77 FT TH S 55-39-53 W 63.16 FT TH S 48-39-58 W 55.63 FT TH S 39-21-15 W 88.24 FT TH S 30-04-58 W 85.21 FT TO MOST WLY COR OF PARCEL 2 TH S 37-36-40 E 20.92 FT TO POB - OF CITY OF TUKWILA SHORT PLAT NO 79 -7 -SS RECORDING NO 7908210370 SD SHORT PLAT BEING A POR OF GUNDAKERS INTERURBAN ADD IN SW 1/4 OF SEC 24-23-04 - AS PER CITY OF TUKWILA BDRY LINE ADJ NO 90-2-BLA RECORDING NO 9008151101 RCM CONSTRUCTION TYPE: V -B, SPRINKLERED OCCU PANCY: AREA OF SUITE: AREA OF FLOOR: APPLICABLE CODES: TENANT: BUILDING REPRESENTATIVE: ARCHITECT: CONTRACTOR: GROUP B (OFFICE) ± 2,979 SF ± 20,066 SF 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL PLUMBING CODE (IPC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 WASHINGTON STATE ENERGY CODE (WSEC) 2015 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2014 NATIONAL ELECTRICAL CODE (NEC) 2009 ICC / ANSI A117.1 - ACCESSIBLE AND USABLE BUILDINGS & FACILITIES WASHINGTON INDOOR AIR QUALITY CODE FUSE NETWORKS 1ST FLOOR, SUITE 140 7100 FORT DENT WAY TUKWILA, WA 98168 JOHN C RADOVICH DEVELOPMENT 2835 82ND AVENUE SE MERCER ISLAND, WA 98040 PHONE: (206) 267-2669 E-MAIL: REBECCADAVIDSON@JCRDEVCO.COM CONTACT: REBECCA DAVIDSON NELSON 1200 5TH AVENUE, SUITE 1300 SEATTLE, WA 98101 PHONE: (206) 408-8518 E-MAIL: LDUCEY@NELSONONLINE.COM CONTACT: LINDA DUCEY TBD O®.W.oe�tameern.rre.,e.rae,.m116019 r% 0 WASHINGTON STATE CERTIFICATE OF COQ FIR! PROTECTION SPRINKLER SYSTEME Lewis Potent 2800.0691•C Level First Defense Firs Protection, L.L.C. FIRSTDFNIRP beeeessesas Was rrti� c" -s. FIRST DEFENSE FIRE PROTECTION 10212 215TH AVE SE SNOHOMISH, 8'A 98290 P 380-794-9479 PND At -- 3 2 TUI,. IILAFIRE cC/3/-2' PUS N\ wO s \jj-k-A \"41i fl‘ () -Cs?) FIR'•T FLOOR DATE 02/1/18 SCALE AS NOTED DRAWN JOB NO. 17-078 DWG. NO. • 2 MECHANICAL, PLUMBING, FIRE PROTECTION & LIFE SAFETY NOTES NTS FORT DENT PARK GPEEN RIVER FORT DENT 111 7100 FORT DENT WAY EXISTING OFFICE BUILDING z 1N��RS� PTE �p5 NORTH VICINITY MAP NA SITE PLAN NA iendadde uormalsA Jo UMOP -Inqs v SS) zilluod ,A55 rue LCF7':'-5fS� ,1.(` g21WiliVd2 Aq uol adsul pue prip 12UEJ 1en0adcl lua!lha`.:igri ;Y 12)41wgnsaJ C? aiinhaa ;ilt,', pie illrh a:y'p Jaw S6U!MWP 7sail:l U1 S !0rni, = :t.)i' is 'suoplppV •JauSFsap al.I) (pm AlleaO;..._ ..> ,,;i ii=�� 10 Aapnbape aq1,16.4 701IIClsuodsa., 0111.•:,:j0,_.:.UI1.>.,0 i).. ; spaepuels pagdope 40 suoi4el0iA azpo.4;u si.' .,.r .: ; : ?.toigiv' Su0l.Ss1UJO pue siona pacgns rst ;:r. u2:Ida)DH •spaepums AlIO lua un0 itwo aDuewio4uo3 .!OJ neaang u0l uaAaad aal� ellM)nl all Aq paMalnaa uaaq anal sueld asayi as al PUD 2 V LII Jed pad uI paION St, sS,uawwo3 4not.pM 3 DI EXISTING TENANT SUITE flax. 14F m: L uS � PEA E ? I� /. 1„L �` ��� Lac_ tom,Pk...0 Nt r\ 1 .�5`C .tet; c S NN ik_4__) EXPANSION AREA REFLECTED CEILING PLAN' SCALE: 1/8" =1'-0" 0 5' 10' 20' 30' 2111. N 1'A \? .Y 'HA? — co M. oo -v - R- X12 Ls—, lam. �`/� C \rr P 1 1 T Ar CT` \iL YZ ,S r-15 r1 \A_ Ur {`" A\@. ,. NORTH --{ J Ci` O 7 3� m rn c- rn� cn rn rn O NIVINf1O1A1 NJJID Ja'flMN III lNJG fIOd SCOPE OF WORK: TENANT IMPROVEMENT TO EXPAND E)i ISTING SUITE OF AN EXISTING 2 -STORY OFFICE BUILDING FOR OFFICE USE TO NCLUDE: • DEMOLITION OF INTERIOR PARTITIO S, DOOR & RELITE • CONSTRUCTION OF INTERIOR PARTI-`IONS, DOORS, RELITES & CASEWORK • NEW PAINT AND FLOORING IN AREAS OF SUITE • INSTALLATION OF RELOCATED LIGHT FIXTURES SITE ADDRESS: FORT DENT III 7100 FORT DENT WAY, SUITE 150, TUKWILA, WA 98168 PARCEL NUMBER: 295490-0440 LEGAL DESCRIPTION: GUNDRAKERS INTERURBAN ADD PAR EL 2 LESS GEG MOST WLY CORNER OF PARCEL ' TH N 63-35-49 E 237.32 FT TH S 26-24-11 E 227.32 FT TO COMMON COR BTW PARCELS 1 & 2 TH N 63-35-49 E 25 .25 FT TH N 26-24-11 W 77.65 FT TH N 56-15-11 W 234.09 FT TH N 31-12-43 W 8 .39 FT TO INTSN WITH NWLY LN OF PARCEL 2 TH S 58-47-17 E 102.77 FT TH S 55-39-53 W 63.16 FT TH S 48-39-58 W 55.63 FT TH S 39-21-15 W 88.24 FT TH S 0-04-58 W 85.21 FT TO MOST WLY COR OF PARCEL 2 TH 8 37-36-40 E 20.92 FT TO OB - OF CITY OF TUKWILA SHORT PLAT NO 79 -7 -SS RECORDING NO 790821037 SD SHORT PLAT BEING A POR OF GUNDAKERS INTERURBAN ADD IN SW /4 OF SEC 24-23-04 --- AS PER CITY OF TUKWILA BDRY LINE ADJ NO 90-2-BLA ECORDING NO 9008151101 ZONING: RCM TYPE OF CONSTRUCTION: V -B, FULLY SPRINKLERED OCCUPANCY: AREA OF SUITE: AREA OF WORK: APPLICABLE CODES: TENANT BUILDING REPRESENTATIVE: ARCHITECT: GENERAL CONTRACTOR: PLAN NORTH SCALE 1/43=1-0" GROUP B (OFFICE) ± 2,886 SF ± 726 SF 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL MECHANICAL CO 2015 WASHINGTON STATE ENERGY CO 2015 INTERNATIONAL FUEL AND GAS C 2014 NATIONAL ELECTRICAL CODE (NE 2009 ICC / ANSI A117.1- ACCESSIBLE Al WASHINGTON INDOOR AIR QUALITY CC KEURIG GREEN MOUNTAIN 7100 FORT DENT WAY, SUITE 160, TUKWILA, WA 98168 PHONE: NA EMAIL: Marc.Bard.@gmcr.com CONTACT: MARC BARD IBC) (IPC) )E (IMC) )E (WSEC) )DE (IFGC) 3) ID USABLE BUILDINGS & FACILITIES DE JCR DEVELOPMENT COMPANY 2835 82ND AVENUE SE, SUITE S1, MERCER ISLAND, WA 98040 PHONE: (206) 267-6060 EMAIL: RebeccaDavidson@jcrdevco.com! CONTACT: REBECCA DAVIDSON NELSON 1200 5TH AVENUE, SUITE 1300, SEATTLE, WA 98101 PHONE: (206) 408-8500 EMAIL: MEvans@nelsononline.com CONTACT: MARK EVANS DP INCORORATED 19936 BALLINGER WAY NE, SEATTLE, WA 98155 PHONE: (206) 361-2989 EMAIL: vshadrin@dpi.com CONTACT: VASILY SHADRIN WASHINGTON STATE CERTIFICATE OF COMPETENcy FIRE PROTECTION SPRINKLER SYSTEMS CsTeA PAID JAN 26 2fl1,' TUKWILA FIRE ec /2-00— SM- FIRST DEFENSE FIR7 PROTECTION LLC SPRINKLERS BEAT FIREMEN TO THE BLAZE 10212 215th AVE SE PHONE (360} 794-9475 SNOHOfISH, WA 98290 PROJECT % GREEN ry i i -I ADDRESS J \OO' wA SU, E 1, (,0 CITY t. J IA f 1 t \ c st 6 1< TITLE LIC/ 602-250-698 BRAWN LP FIRE SPRINKLER PLAN DDT CAD FILE DWG H SITE MAP SCALE: V-0"=801-0" • Fr.+ Trra ors( :trys t CI Without Comments ID As Noted in Red )Er Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance With current City 5t.widards. Acceptance is subject to errors and offlissions which do not authorize violations of adopted standards and ordinances. The responsibility, for the baequacy of design rests totally with the desjgner. Additions, deletions (.,!' evisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequegt approval. Final acceptance Is subject to fleld test and Inspection by The Tukwila Fire Prevention Bureau. Date: 1 -M By: 1 Fire Permit Number To schedule inspections call 206-575-4407 FORT DENT III BUILDING 7100 FORT DENT VAY, TUKWILA, WA 98188 FORT DEN PARK .1-rEcks-ci""- A's LOCATION MAP AN-Oi NOT TO SCALE • ...... • _ • (13 PROJECT TRUE NORTH NORTH rauiii 111.11 , 1.1 •'.. V, • . Vs, .. y, 10,41,'.... "1.;111(,4,,,—, • . : ''''':: .11111.111 i•I 104 1 INIIINKM, 105 1 II riIII1I 107,1111110•111 -1•11-11111111ramarica IMM Eli ACT r- - 111111n011MITMOlowziN101111110_1_12L • 1.0111111111111 Ism. 1111.: Joximo•111111111111111 111.-,1L--11111—. • • 101 102 mai IN NMI UMW REFLECTED CEILING PLAN SCALE:1/8" = 11-0" ••••(I*IIMEID CJ — 0 LO C) CDUU- (3 \ 5-•-• . • t1.1 • 0 / Ho ci A o 0 SCALE: 1/8" = 16' C tAr- tx,/ ........ maioeireemmeemeposowers1 seampicalvassimmiTs or STATI owrinumey MI mammies aressuast SWUM 1 11 11 Lewis Peters1 2800-0691-C Level 3 First Defense Fire Pretectbn, LLC FIRSTD1i,“ 1:11W ira mem Gomm 121311111 eincerou ..... meow esmetudil BUILDING INFORMATION SITE ADDRESS: PARCEL NUMBER: LEGAL DESCRIPTION: ZONING: BUILDIN DESCRIPTION: YEAR BUILT: CONSTRUCTION TYPE: FIRE PROTECTION: NUMBER OF STORIES BUILDING TOTAL FLOOR AREA: revisions client . ....... • . , — . ••• • .„ JCR DEVELOPMENT 2835 82ND AVE. SE SUITE S-1 MERCER ISLAND, WA 98040 TABOR 100 TENANT IMPROVEMENT 7100 FORT DENT WAY, SUITE 100 TUKWILA, WA 98168 project name & address REFLECTED CEILING PLAN sheet title 7100 FORT DENT WAY, TUKWILA, WA 98168 295490-0440 GUNDRAKERS INTERURBAN ADD PARCEL 2 LESS BEG MOST WLY CORNER OF PARCEL 1 Th. N 63-35-49 E 237.32 FT TH S 26-24-11 E 227.32 FT TO COMMON COR BTW PARCELS 1 & 2 TH N 63-35-49 E 252.25 FT TH N 26-24-11 W 77.65 FT TH N 56-15-11 W 234.09 FT TH N 31-12-43 W 82.39 FT TO INTSN WITH NWLY LN OF PARCEL 2 TH S 58-47-17 E 102.77 FT TH S 55-39-53 W 63.16 FT TH S 48-39-58 W 55.63 FT TH S 39-21-15 W 88.24 FT TH S 30-04-58 W 85.21 FT TO MOST WLY COR OF PARCEL 2 TH S 37-36-40 E 20.92 FT TO POB - OF CITY OF TUKWILA SHORT PLAT NO 79 -7 -SS RECORDING NO 7908210370 SD SHORT PLAT BEING A POR OF GUNDAKERS INTERURBAN ADD IN SW 1/4 OF NW 1/4 OF SEC 24-23-04 --- AS PER CITY OF TUKWILA BDRY LINE ADJ NO 90-2-BLA RECORDING NO 9008151101 RCM TWO-STORY OFFICE BUILDING WITH SURFACE PARKING LOT 1999 - PER JURISDICTIONAL RECORD V -B FULLY SPRINKLERED (NO CHANGES) 2 ±40,922 SF (NO CHANGES) PROJECT DIRECTORY TENANT: BUILDING REPRESENTATIVE: ARCHITECT: CONTRACTOR: TABOR 100 JOHN C. RADOVICH.DEVELOPMENT 2835 82ND AVENUE SE, SUITE S-1, MERCER ISLAND, WA 98040 PHONE: 206-267-2669 EMAIL: REBECCA@JCRDEVCO.COM CONTACT: REBECCA DAVIDSON NELSON WORLDWIDE 1200 5TH AVENUE, SUITE 1300, SEATTLE, WA 98101 PHONE: 206-408-8537 EMAIL: KMATHWEG@NELSONWW.com CONTACT: KATIE MATHWEG DP INCORPORATED GENERAL CONTRACTORS 19936 BALLINGER WAY NE, SEATTLE, WA 98155 PHONE: 206-361-2989 EMAIL: VASILY@DPINC.NET CONTACT: BILLY SHADRIN •_________ FIRST DEFENSE FIRE PROTECTION 10212 215171 AVE SE SNOHOMISH, TA 98290 P 880-794-9479 Olt imm- -'-- ' ot) \-7---oc'-v-b•FtL.- ,(J-', . t,up\ 0\% V . . DETAILS jam NO. 10W0. NO. . . . .. DATE (0 . 11 I (3 SCALE AS NOTED.rrfv-, \ . Lkt. 20 - 0 Z5 - O E. • 525 - 0 0 E' 4 TP ELEVATOR W0:=8) :64) 1`(P. -j 0 1 NON -ACCESSIBLE / N -VOID SPACE - NAS Without As Note• ❑ Per The se plans have beenr MBUSTIBLE omments In Red ttached Letter ---.re._— viewed bT e Tukwila Fir dards. Acceptance is subject to errors and ornis8ons which do not authorize violations of adopted standards and ordinances. The responsibility for the adeg9 cy of design rests totally with the designer. Additions, deletions or revisions eo these drawings after this data will void this acceptance and will require a ttal of revised drawings for.subsequent approval. rr Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date:3 3/f. HEAD LEGEND MAKE 1. • RELIABLE • RELIABLE THE COMPLETE LINE/ 170483 .5f/Sc_2-- SRINKLERLER PLAN "e 0 8 16 SCALE 1/8"=1'-0" 474/ -bvoc2D. 244P ,/2cA- nI- TYPE SSP SSP MODEL G-REC G XLO-ECOH FINISH CHR CHR Cai.es7e ,C /> /16-41. ESC ORIFICE THRD TEMP CHR 1/2 1/2 165° CHR ' .64 3/4 165° QTY 5 5 SCOPE OF WORK: SMITH FIRE SYSTEMS WILL MODIFY THE EXISTING FIRE SPRINKLER SYSTEM TO INCORPORATE THE REMEDY INTELLIGENT STAFFING TENANT IMPROVEMENT. SFS WILL ADD 1" DROPS FROM THE EXISTING OUTLETS TO BELOW THE SUSPENDED CEILING AND CUT IN NEW OUTLETS AS NEEDED. DESIGN CRITERIA: -PER NFPA #13-1996 AND WSRB ORDINARY HAZARD GROUP 1 - .15 GPM OVER 1500 SQ. FT. FITTER/LISTER NOTES: 1) ALL MATERIALS TO BE UL LISTED AND/OR FM APPROVED. 2) (N) = 2" X 1" PIPE STRAP. 3) (R) = RELOCATE EXISTING SPRINKLER HEAD. (E) = EXISTING SPRINKLER HEADS. ALL DROPS TO BE 1" X I'-3"c/c TYPICAL, UNO. EXISTING SPRINKLER PIPING IS SHOWN AS DASHED LINES. ILA FIRE DEPARTMLP L 4) Please call: 575-4407 and give this job 5) tO ( and exact address for shut- 6) dawn or restoration approval. ROOM SHEDULE RM ROOM CEILING CEILING # NAME HEIGHT TYPE 101 OFFICE 8'-0" ACT 102 VIEWING 8'-0" ACT 103 TESTING 8'-0" ACT 104 STORAGE 8'-0" ACT 105 OFFICE 8'-0" ACT 106 OFFICE 8'-0" ACT HANGER LEGEND: D - GRINNELL FIG. 92 TOP BEAM CLAMP, 3/8" ATR, 8" RETAINER STRAP, & RING. KEY PLAN NTS FILE SMITH FIRE SYSTEMS, INC. 1106 54th Ave. E. Tacoma, WA 98424 CONTR. REG. NO. SMITHFS1360T Ph: (206) 926-1880 Fax: (206) 926-2350 PROJECT REMEDY INT. STA 7100 FORT DENT WA TU KW I LA, WA. DESIGNER BARRY GOODING MTN- MAR 17 1999 3 - I4-99 1 OF 1 JOB NO. TI -III HYDRAULICALLY MOST DEMANDING AREA: SYS* 1 DENSITY: .15 GPM OVER 1500 SQUARE FEET SYSTEM DEMAND AT BOR: 528.17 QPM AT 48.85 PSI (INCLUDING 0 GPM FOR INSIDE HOSE STREAMS) HANGER LEGEND 2ND FLR. T.I. SPRINKLER PLAN 0 4 8 SCALE 1N'-1'-0' FITTER / LISTER NOTES 1. TYPICAL DROP TO BE 1(1-0) TOE. 2. TYPICAL HANGER TO BE IT' TYPE. 3. TYPICAL CEILING HEIGHT AT 8'-" AFF. SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND QUALITY CONTROL BY: DATE 2' TAPPED SOUARE WASHER WITH 3/8' X 54' (CTS) ATR GYM • • MANUFACTURER RELIABLE RELIABLE TYPE MODEL SSP Q REC 8SP GXLO•ECOH ewm•°, CHR CHR CHR CHR 1/2' .64' 1/2' 3)4' 166 165 19 10 AFF 808 BOD BOJ BOP DDT 018 FO 4.65 OFOW NAB LINO ABOVE RFORED ROOK RONDIJ OF 8E05 WO/ OF DECK 80110 4 OF JOIST WHOM OF RTRUN BOTTOM OF MSS CUT TO SUIT ROD OAOER POLE FACE OF WALL MILE FACE OF WALL NO AUTO. SHOWILY) ME89 NOTED OTIEAV8SE CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2•WAY EARTHQUAKE SWAY BRACE LEITER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE LEITER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO DATE BY REVISIONS REASON FOR REVISION APPROVED FOR FABRICATION AREA BY DATE CONTRACT WITH FOUSHEE & ASSOCIATES 3260 118TH AVENUE S.E. P.O. BOX 3767 BELLEVUE, WA 98009-3767 PROJECT MANAGER : MIKE FEY PHONE : (425) 748-1000 FAX : (425) 7483737 SUPERINTENDENT : SKIP STEINBACK PHONE: FAX : GENERAL NOTES 1. AU. COUPLINGS WITH (F) TO BE FLEXIBLE 2. ALL NEW PIPE TO BE AS FOLLOWS: STEEL PIPE ASTM A-795 OR BETTER 25'40• 25'41' 25'-0' 25'-0' `r END PREP TYPES ALLOWED mall? OF vane/ CAPACITY 84=Lo„L ..-� .--� 10.47 0.133 1.049 THREADED, CUT GROOVED, ROLL GROOVED, PLAIN END, POLISHED 1 I ( 1 1 I II ! I 1 ROLL GROOVED, POLISHED, PLAIN ENO (FOO BUTT WELDING) 1.817 0.097 1 1 Iz SUPER-FLO 2 172.448D. ROU. GROOVED POUSIED PLAIN ENO(FOR BUTT WELDING ) 2 ' 3UPER.FLO 0.074 2 ROLL GROOVED POLISHED PLAIN END WHDI FOR BUTT NO , ( ) 3.468 2' 21/2 O 21 1 2 4.734 0.303 3 r- 0.074 3.352 2' 6.626 0.458 4 11 0.074 4.352 ------'--------.._...._ 9.927 --------- -1"-------- 10 0.134 __._ 18-0 ___........___._. 17.300 _ ...__._-__......._..L 1' 0.134 8.357 9-0 23.030 O 1 1 14-0 I 1 14.01 1 to 1 1 I 1 I I � �N 1 I I I I I C I V 18 1 STAIR #12 I 1,1 1 . : I 9@AFF I �, ADJ EENT 1 LEASE.AREA_ I... .. ...-1 1 1 1 1 I 1 i Il I II 11 .-_..__._..._.._: I „-- I I I I I 1 L I 1 I 1 1 I 1_-- 1 I }l am tl� 12-8 0 --!- -I .I I I� II I NEW BAANCHUNE I 1 I I°R" 3 I I I I 2 I I� I 7 I 1- I -11 • I ®.___ _ �--�-- tF0 ---d 0-- •- - ------1....yo-0 - ----- -- ---- ------ s3 - � sa-- • i' y.o • -. -. •1 51 I , I I I l7 1 1 1 I I 2 $I1 �l °� I I 2' l 1 ---------0 • ..--- ,8-0 i • ("'© ,` 11i-0 ® �) -�, ' t 253 - 252 I i,o , I .�) 14-0 ® • 14-0 _ • 141 , I COMMON CORRIDOR I • ,`, 1 12091 L- L 1 q- - R -- Z-0 3s1 STOR IT P ICE OPY/MAIL CONF ENTRY] I ' i •4 Egg E� % 1203 1 j 1 pQ2J I -' 12C1 1 1 I NEW BRANCHUNE •- - _ I 1 ./ MEC. 2 GRV C OSS 2 2 !�� ! .---"-1 _ 2 °1 ) 1 83 11.9 •` I H • 7{ •I�1 1 LL • 7.3, ✓ NO 0-B 10-0 • 8 0I • 1 1 � 1 - 0 GC)1 © �Q� �' i 355 1 I 53 - 1 �Q• I I I I C i N 1 I L c+° IItItItIII���itltlttll�tlltll��e A IIS 2 2 2 �, 2 2 2 2 2 2 2 2 2 2 2 1 1 180 • ' 1tr0 1-0 ' 3-0 8{ ' 8-0 9-0' 1-0...__$-0 1-0 ' 3-0 ' 13.0 ' a-0 1 1 --------}---- ---- --� 286 - --'--- ---------- -- ------ O'-• I - -' ._. _..-------.....---- ------------ --------1_._...-- --- ® I'-"---------- ---- -----._--- ----I----------- ------1--- ------------ -----.j-.._.._--- ---..----- -----..._. ___ I ■ ©� ' -pBX II O 12071 I /� I 1 } ' ' 1 2ND FI;.R LOBBY I 1 I I I OP E F1 OFFICE] I 1 J 1 4 208 j q - - -1 - - - 1 -- - -IIIIIIIIIIIIIMI 1-- -y I 1 1 1 1 fi 1- � 1____ 1 --- ----I -- 1 1 I I I I A `• ^� I 1 1. ! 4f 1 I ! • 1 I - I 1 I O 1 2 I 1 2 I 2 2 1 2/ 2 1 ' 12 2 1 1 2 1 / 21 2 1 . I 18-0 I I I 16-0 I • .-i 1.0_ _ c -- 9G i 6-0 13431--,-0 1 3A 3-0, 13-0 /r 2-0 1 m 1 I I 1 I 1 I 1 I 1 I 1 1 I I 1 I I 1 I - _ - -I_ - - -1 1 J I I - _._.. _.... - I - 1-..... - -C- -- - __ _ -__ 1_ - - _- HYDRAULICALLY MOST DEMANDING AREA: SYS* 1 DENSITY: .15 GPM OVER 1500 SQUARE FEET SYSTEM DEMAND AT BOR: 528.17 QPM AT 48.85 PSI (INCLUDING 0 GPM FOR INSIDE HOSE STREAMS) HANGER LEGEND 2ND FLR. T.I. SPRINKLER PLAN 0 4 8 SCALE 1N'-1'-0' FITTER / LISTER NOTES 1. TYPICAL DROP TO BE 1(1-0) TOE. 2. TYPICAL HANGER TO BE IT' TYPE. 3. TYPICAL CEILING HEIGHT AT 8'-" AFF. SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND QUALITY CONTROL BY: DATE 2' TAPPED SOUARE WASHER WITH 3/8' X 54' (CTS) ATR GYM • • MANUFACTURER RELIABLE RELIABLE TYPE MODEL SSP Q REC 8SP GXLO•ECOH ewm•°, CHR CHR CHR CHR 1/2' .64' 1/2' 3)4' 166 165 19 10 AFF 808 BOD BOJ BOP DDT 018 FO 4.65 OFOW NAB LINO ABOVE RFORED ROOK RONDIJ OF 8E05 WO/ OF DECK 80110 4 OF JOIST WHOM OF RTRUN BOTTOM OF MSS CUT TO SUIT ROD OAOER POLE FACE OF WALL MILE FACE OF WALL NO AUTO. SHOWILY) ME89 NOTED OTIEAV8SE CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2•WAY EARTHQUAKE SWAY BRACE LEITER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE LEITER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO DATE BY REVISIONS REASON FOR REVISION APPROVED FOR FABRICATION AREA BY DATE CONTRACT WITH FOUSHEE & ASSOCIATES 3260 118TH AVENUE S.E. P.O. BOX 3767 BELLEVUE, WA 98009-3767 PROJECT MANAGER : MIKE FEY PHONE : (425) 748-1000 FAX : (425) 7483737 SUPERINTENDENT : SKIP STEINBACK PHONE: FAX : GENERAL NOTES 1. AU. COUPLINGS WITH (F) TO BE FLEXIBLE 2. ALL NEW PIPE TO BE AS FOLLOWS: STEEL PIPE ASTM A-795 OR BETTER PIPE BRE SCHEDULE WALL THICKNESS INTERNAL DIAMETER END PREP TYPES ALLOWED mall? OF vane/ CAPACITY 84=Lo„L 1 40 0.133 1.049 THREADED, CUT GROOVED, ROLL GROOVED, PLAIN END, POLISHED 2.053 0.044 1 1/4 SUPER-FLO 0.059 1.642 ROLL GROOVED, POLISHED, PLAIN ENO (FOO BUTT WELDING) 1.817 0.097 1 1 Iz SUPER-FLO 0.07452 172.448D. ROU. GROOVED POUSIED PLAIN ENO(FOR BUTT WELDING ) t 26 2 3UPER.FLO 0.074 2.227 ROLL GROOVED POLISHED PLAIN END WHDI FOR BUTT NO , ( ) 3.468 0.202 21/2 SUPER-FLO 0.074 2.727 ROLL GROOVED, PLAN ETD (FOR BUTT WELDING) 4.734 0.303 3 SUPER-FLO 0.074 3.352 ROLL GROOVED, PIAN END (FOR BUTT WELDING) . 6.626 0.458 4 SUPER -R.0 0.074 4.352 ROLL GROOVED, PLAIN END (FOR 8U1T WELDING) 9.927 0.773 5 10 0.134 6.295 ROLL GROOVED, PIAN END (FOR BUTT WELDING) 17.300 1.144 6 •• 0.134 8.357 ROLL GROOVED, PLAIN @n (FOR BUTT WELDING) 23.030 1.849 8 •• 0.188 8.249 ROLL GROOVED, PLAIN EFL (FOR BUTT WELDING) 40.080 2.78 •• WALL THICKNESS PER NFPA 0 13 SCOPE OF WORK SMITH FIRE SYSTEMS (SFS) WILL MODIFY THE EXISTING WET PIPE AUTOMATIC SPRINKLER FIRE PROTECTION SYSTEM TO'PROTECTTHE NEW TENANT IMPROVEMENTS. SFS WILL START WORK AT THE EXISTING OVERHEAD SPRINKLER PIPING. CLARIFICATIONS - ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED ATA MINIMUM OF 40° F BY OTHERS TO PREVENT FREEZING. - SFS ASSUMES THE STRUCTURE TO BE ADEQUATE TO SUPPORT THE SPRINKLER SYSTEM EXCLUSIONS - PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT • ELECTRICAL WIRING OF ANY KIND - CENTRAL STATION MONITORING EQUIPMENT, WIRING AND MONITORING SERVICES DESIGN CRITERIA ORDINARY HAZARD GROUP 1 PER NFPA 13 (1996 ED.) CE TE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city fandards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the :adequacy of design rests totally with the designer. Additions, deletions or revisions .) these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. 511-171:)1 Date: k By: TUKWILA FIRE DEPARTMENT; Please call: 575.4407 and give this job No. and exact address for sh t down or restoration approval,. MAY 1 Z 999 SMITH FIRE SYSTEMS, INC. TAOOMMA, th AVE 84 TACWA 9642424 CONTR. REG. N0. SMITHFS1380T Bus: (253) 926-1880 FAX: (263) 926-2360 HYUNDAI T.I. 7100 FORT DENT WAY TUKWILA, WASHINGTON DESIGNER L COLE DATE 5.11-99 SHEET 1 OF 1 JOB N0. T1-119 N.I.C. 203 204 E 8'-t' E /EXISiT E E 1- 2 MAX 5'-0" 5'-0" 4" STEEL :AR JOISTS E 202 4-6 EXIST iii////////.///////////////// 0-41. 1 ELEVATOR LOBBY 1 1 /2" E � 1 1-10 81-0" 1 -0 2-0 V/////////// 8'-Q' -0 200 OPEN - �x SECOND FLOOR PIPING PLAN REFLECTED CEILING SCALE: 1/4" =1'-0" 201 112" SSU 1" ARM -OVER (VARIES) 1" POL EXISTING 1" DROP EXISTING EC PEND. NEW EC PEND. DROP DETAIL TOP OF BAR JOIST RETAINER STRAP. AFCON MODEL 160 SCALE: N T S BRANCHLINE 1 MAIN BEAM CLAMP / C -CLAMP WITH SET SCREW. AFCON MODEL 100 3/8" ALL THREAD ROD. =MU PIPE SWIVEL RING. AFCON 300 HANGER DETAIL SCALE: N T S 3/8" HEX NUT, WASHER & FENDER WASHER ABOVE AND BELOW TOP CHORD. TOP CHORD OF STEEL JOIST. 3/8" ALL THREAD ROD. PIPE SWIVEL RING. HANGER DETAIL SCALE: N T S SCOPE OF WORK 1. ARCHER CONSTRUCTION TO RELOCATE AND ADD THE FIRE • SPRINKLERS FOR NEW TI WALLS AND CEILING CONFIGURATIOI 2. EXISTING SYSTEM IS ORDINARY HAZARD GROUP I. • FILE 3 TUKWILA FIRE DEPARTMENT. Please call: 575.4401 end give this job No. and exact address for shut• down or restoration approval. CCErTE Without Comments As Noted In Red 0 Per The Attached Letter EXISTING HEADS ARE EXTENDED COVERAGE (16x16) 256 SQ. FT. MAX A HEAD. 8'-0" MAX. OFF WALLS. 4. ALL AREAS ABOVE CEILING ARE PROTECTED BY EXISTING UPRIGHT SPRINKLERS. CLAIRIFICATIONS ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED AT A MINIMUM OF 40° F (BY OTHERS) IN ORDER TO PREVENT THE PIPE FROM FREEZING. EXCLUSIONS TAXES OF ANY TYPE. ELECTRICAL OF ANY TYPE. SPRINKLER HEADS CENTERED IN CEILING TILE ANY ADDITIONAL TENANT IMPROVEMENT WORK. STRUCTURAL VERIFICATION. ABATEMENT, PREPARATION FOR & PAINTING OF ANY TYPE. DESIGN CRITERIA THROUGHOUT: HAZARD: G PER NFPA #13 (1999 EDITION) AND CITY OF TUKWILA ORDINARY HAZARD GROUP NERAL NOTES 1. ANG ALL ARM -OVERS GREATER THAN 1'-0" PER NFPA 13, 1999ed. 6-2.3.4 ex. (100+ PSI) SEE HANGER DETAIL "D" ON SHEET FPI OF 1. 2. HEADS ARE NOT REQUIRED TO BE CENTERED IN CEILING TILE. 3.. ALL NEW PIPE TO BE 1" EDDYTHREAD. These plans have been reviewed by The Tukwila Fire4' Prevention Bureau for conformance with current city standards. Acceptance is st. bject to errors and • omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions o these drawings after this date will void this, acceptance. and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: // — �l "O c� By: 4:1'.-5-1 ( ADD NEW ECOH SPRINKLERS W/ NEW 1" TEE 1'-0" ABOVE CEILING (SEE DETAIL #1 ON FP1 OF 1), OR 1 x 1%. MECH T LEGEND MT= E0 P -O A 112'S EXISTiN3 SPRINKLER PIPE. NEW SPRINKLER PIPING. MECHANICAL TEE. EXISTING PENDENT HEAD TO REMAIN - EXTENDED COVERAGE 16 x 16. EXISTING PENDENT HEAD TO BE REMOVED. EXISTING 1" OUTLET LOOKING DOWN. EXISTING PENDENT TO BE RELOCATED - EXTENDED COVERAGE 16 x 16. (2 TOTAL) NEW CHROME PENDENT HEAD W/ REC'D ESC. RELIABLE MODEL GFR VELO-ECOH. (2 TOTAL) NEW CHROME PENDENT HEAD W/ REC'D ESC. RELIABLE MODEL F1. (2 TOTAL) AREA OF WORK KEY PLAN U/S FOR REFERENCE ONLY SCALE: N T S HANGERS ATTACHMENT NOTES REVISIONS ABBREVIATIONS SPRINKLER SYMBOLS A B C D E F G H J K L M N BEAM CLAMP W/ RETAINING STRAP SIDE BEAM BRACKET EYE SOCKET NUT & PLATE WASHER WEDGE ANCHOR CONCRETE INSERT - HDI -P SAMMY SIDE WINDER - GST 20 SAMMY SCREW - SWG 20 TRAPEZE CEILING FLANGE U -HOOK SHORT STRAP IA/AI I RRC(:I(I T DATE DESCRIPTION BY AFF BOB BOD BOJ BOP BOT CTS FO IFOW pFOW NAS UNO --11-- ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE FLEXIBLE COUPLING RIGID COUPLING SYM MAKE MODEL THREAD ORFICE TEMP FINISH ESCUT. QTY • R RELIABLE GFR-ECOH 3/4" 17/32" 155°F CHR RECD 2 • A RELIABLE GFR-ECOH 3/4" 17/32" 155°F CHR REC'D 2 •1/2" RELIABLE F1 1/2" 1/2" 155°F CHR REC'D 2 RONALD & ASSOCIATES FORT DENT III 7100 FORT DENT WAY TUKWILA, WA 98188 FIRST FLOOR SPRINKLER PLAN PERMIT NO: JOB NO: SO4-110 TOTAL 6 FIRE SPRINKLER DIVISION 7855 S 206TH STREET PHONE 253-872-7222 KENT, WA 98032 FAX 253-872-7277 CONTRACTOR: FOUSHEE AND ASSOCIATES PHONE: 425-746-1000 FAX: 425-746-3737 AUTHORITY: CITY OF TUKWILA DESIGNER: K. WILSON SCALE: ' AS NOTED DATE: DECEMBER 06, 2004 REVISED / / PLATTED / agPk..0,it 0 L. 3P.0 05V ----- 96/70/90 N0009 BMP -I'd. OZT-T.L\OZT-T.L\9ZT-II oy TOT-T.L\seTTa 4oC\Tmae,L\Punog lebnd yInos\sooQsds\:O -•- 25'-0" - 25'-0" -..1 II 25'-0" O EXISTING CORRIDOR ,,,,,,,,,,,, SPRINKLER LEGEND SYM • • MANUFACTURER RELIABLE RELIABLE SPRINKLER PLAN TYPE MODEL FINISH H7IS SSP G XLO-ECOH CHR SSP G-REC CHR ESCUTCHEON FINISH ORIFICE SIZE THREAD SIZE TEMP. RATING QUANTITY CHR 1/2" 1/2" 165° 13 CHR 1/2" 1/2" 165° 4 SCOPE OF WORK SMITH FIRE SYSTEMS (SFS) WILL MODIFY THE EXISTING SPRINKLER SYSTEM TO INCORPORATE THE CLINIQUE TENANT IMPROVEMENT. SFS WILL ADD BRANCHLINE 215A, ADD DROPS FROM EXISTING PIPING, AND CUT IN NEW OUTLETS FOR DROPS AS NEEDED. DESIGN CRITERIA LIGHT HAZARD: .10 GPM OVER 1500 SQ. FT. BUILDING SHELL DESIGNED TO ORDINARY HAZARD GROUP 1: .15 GPM OVER 1500 SQ. FT. PER NFPA 13 (1996 EDITION) FITTER/ LISTER NOTES 1. RUN ALL PIPE 9' - 3" AFF. 2. ALL DROPS 1 x 0' - 9" UNO. 3. ALL HANGERS TO BE TYPE D. 4. (7) "AS" = ADD W/ 2" x 1" STRAPS (STRAIGHT DOWN). 5. (6) "T" = ADD W/ 2" x 1" STRAPS AND ARM OVER. 6. (4) "N" = ADD FROM NEW BRANCHLINE. 7. (6) "P" = PLUG EXISTING OUTLET. 8. CEILING HEIGHT AT A.C.T. IS 8' - 6" UNO. 9. ALL THREAD RODS TO BE 40" C.T.S. HANGER LEGEND D - TOP BEAM CLAMP W/ RETAINER STRAP AREA OF WORK (SECOND FLOOR) KEY PLAN CC .. T Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire P evention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. AJditions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings forsubsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. D ate: ?/[/f f By: SMITH FIRE SYSTEMS, INC. r 1106 54th AVE EAST TACOMA, WA 98424 CONTR. REG. NO. SMITHFS1360T Bus: (253) 926-1880 FAX: (253) 926-2350 CLINIQUE TENANT IMPROVEMENT FORT DENT III 6860 FORT DENT WAY TUKWILA, WA DESIGNER B. COOK DATE 6/3/99 SHEET 1 OF JOB NO. Ti -120 F FUKWILA FIRE DEPARTMLN1 Please call: 575-4407 and give this job lJ and exact address for shut- down or restoration approval. 7/0 /j ii may. I FIIL IRIOEELTM gi JUN 0 4 1999 7100 FORT DENT WAY ASSOCIATED PERMITS D19-0222 D18-0073 D18-0001 D17-0283 D16-0346 D16-0294 D05-275 D99-0190 D97-0395 M98-0228 19-F-192 18-F-099 18-F-005 17-F-211 17-F-012 17-F-006 14-F-023 13-F-289 10-F-100 08-F-300 05-F-215 99-F-235 99-F-234 99-F-212 99-F-203 99-F-178 99-F-069 19-S-211 18-S-104 18-S-029 17-S-236 17-S-019 16-S-238 14-S-031 08-S-259 05-S-208 05-S-176 05-S-028 04-S-240 02-S-222 99-S-232 99-S-211 99-S-204 99-S-180 99-S-149 99-S-091 SITE LOCATION Site Address: CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 710o Farr Tenant Name: tiaX — � C -L 4 o^ King Co. Assessor's Tax No.: Zq S "[ 1 0-0 Lf L/ D Suite Number: Floor: Property Owner's Name: New Tenant? ❑ - Yes ❑ - No Mailing Address: L0 �' (� C-V�'� ( c- &' yvv-c fir^ 4,e tvA 16-e <it 6 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Company Name: Day Telephone: Mailing Address: lbs— Y\-- �L 15 �� _ SL S im SSL LAp., qS*-261. 0 E-mail Address: --(\l ,�J k-C-FaxNumber: 266 `1.`te ���^� 1 _ Contractor's City of Tukwila NICET III number: Business License number: Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 2-\H v 0 L oCA �-- Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN/�UTH� AGENT: Signature: Date: 1 —Zg'e-t Print Name: \— .-4- ` I/V\A ^- Day Telephone: R D () S 1 t 3S v"\-- Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: '71 F'©i-+ Der -1 Suite Number: , Floor: Tenant Name: rn.—U C...- � � New Tenant? ❑ - Yes ❑ - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: .3P jt Ca_ j flfl Day Telephone: 4124 • q J - 7(pW/ Company Name: C Ytt in F1 re. 1 m c -\--i r)C- Mailing Address:' O )©x O'\rl\ cfeescv p\ &3 7 City �Z Cta�ste Zip, E-mail Address: � Ca eCart�WM� . (OM Fax Number: Ej- /- ��,� Total number of new/relocated devices or sprinkler heads: 1 I �p Valuation of Project (contractor's bid price): $2goO©-c0 Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING WNER OR AUTHORIZED AGENT: (C\ Signature: max . Print Name: rj),IthAwf) Je%IC`a `0)-)inSon Day Telephone: Date: , i /eK0 L/2 lig 17190 Plan Permit App.doc 1!2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** rj-� King Co. Assessor's Tax No.: Site Address: ---1/ 0 ^ ✓j f D en l wc1 [ Suite Number:c2O Floor: Tenant Name: AA\(\( -Ful P.M e 4/j New Tenant? g(- Yes ❑ - No Property Owner's Name: VO r L. UVI 1(.1� acid v {0n.e,e1 Mailing Address: c2v 3 5 5c A -- SFr= /VL r er is l,...V144 Lc"Ueitt' City State Zip CONTACT PERSON -if there are questions about the submittal. Name: ((.)SA‘,r\ 61,Ctinlaerri Day Telephone: a 253 -51-2 /'c7$ Company Name: 0 SL rl r; (- Mailing Address: 302 5— U k) r 4 S h Nei ivei Ave-- v v'J,d qg �-1 City State Zip E-mail Address:j u Si Y�c�J�C�ISGSP �.c�-r- L.►Y�°� Fax Number: (� LJ Contractor's City of Tukwila NICET III number: Business License number: g V `' '01'w/6283.2 Total number of new/relocated devices or sprinkler heads: v Valuation of Project (contractor's bid price): $ 5, o U 0 Scope of Work (please provide detailed information): 1(1 bbA\ i1 Gw et/ C c e 5 (p - Cr -Fug . PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature. 6 '"'y' Date: / — 4'70 (-7 Print Name: du) ffit 66%f'7 / Day Telephone: 0253 -07,2 '-1 qC? ( 8/22/14 TFD FP Form 8 Plan Permit App.doc 443"44 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** PAID FEB 24 2014 TUKWILA FIRE King Co. Assessor's Tax No.: Suite Number: Floor: 21\6\ New Tenant? M- Yes ❑ - No Site Address: ,C0 \OC T .\/\.\- Tenant Name: `mak I j v\ ¶ C C Property Owner's Name: Mailing Address: CONTACT PERSON -if there are questions about the submittal. Name:Day Telephone: i-`2A'1-4%I'7Coloci Company Name: QYI�`rP, ����-P Cfi\lNY-.) Mailing Address: V() X v' l \1 C't✓P 1 ` ` 2 — f City State Zip \_ E-mail Address: C� ��',[j.�.�' ���:1nTP. (t YY I Fax Number: �Z�' S\'' Total number of new/relocated devices or sprinkler heads: C Valuation of Project (contractor's bid price): $ 4iSM. cC } Scope of Work (please provide detailed information): ` L1 � � 1 �Q rte` City State Zip PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER QR AUTHORIZED AGENT: } j �%a%u GC. . il2i-fie 1..) Date: 2- i kP 1 V Signature: 0--)1 Print Name: �) €,\Cry. rfl s Day Telephone: 142.53. 4 eiM 1 1.01.p 9 Plan Permit App.doc 1/2/13 TFD FP Form 8 SITE LOCATION Site Address: CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 7 �O� FOS' 1 ft T W Pt King Co. Assessor's Tax No.: Z YW'Cb4 (jZ Suite Number: 6&C) Floor: 1. Tenant Name: Vv' raG R, ,-"' ) New Tenant? ❑ - Yes ❑ - No Property Owner's Name: btue....6/l Mailing Address: i3 kr-O , (AA a &"o 4/4 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: I--"*---- ���►` ((�� ��,, (� � Day Telephone: Company Name: �- l i �'!Elt��' �� rte_ -(4�2-VcCIZ°"1 Mailing Address: 10 `1-1`L 2-13 �j✓�'o,/`�� j\ VvA q$1 -c\ -Z) 11 __ (� City E-mail Address:.Q State i —Cr -5 i• ' t_i'L� ` M�~ �-Coi"Z Fax Fax Number: �� �� l (-1 ( f ^y��,� Contractor's City of Tukwila [ NICET III number: 151�'v"c)6oi, \ Business License number: Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ \ 3e5Z> Scope of Work (please provide detailed information): 1%1)0 k.\7)6Tf__ PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AU HORIZED AGENT: Signature: ii ij� Date: I J 2— Print Name: Plan Permit App.doc i6n Day Telephone: 8/22/14 TFD FP Form 8 44$SW447 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 7100 Fort Dent Way Tenant Name: Keurig Green Mountain Property Owner's Name: King Co. Assessor's Tax No.: Suite Number: New Tenant? ® - Yes ❑ - No Mailing Address: City CONTACT PERSON -if there are questions about the submittal. Name: Matt Carlman State Zip Day Telephone: 253-951-6005 Company Name: Fire Systems West, Inc. Mailing Address: 206 Frontage Rd N, Suite -C, Pacific, WA 98047 City State Zip E-mail Address: mattc firesystemswest.com Fax Number: Contractor's City of Tukwila NICET III number: Bryan Hilflker 99709 Business License number: bus -0994434 Total number of new/relocated devices or sprinkler heads: 15 Valuation of Project (contractor's bid price): $ 2500 Scope of Work (please provide detailed information): Install new fire alarm notification devices for tenant improvement. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTHORIZED AGENT: Signature: [/ I_ Date: 01/24/2017 Print Name: MattCarlman Day Telephone: 253-951-6005 Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No/..:2—°V)VC1(31-0-1(40 Site Address: o V hD(T nrr vV t Vkl,,lr\ Suite Number: /5 Floor: Tenant Name: .eu123g 1 't.3A- leN rv1.O(il,N1-°` New Tenant?, Yes ❑ - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: rixOcv'tc— r‘ Name: 1 P r<SC-- Mailing Address: 1'2_ ti-- 215 (\� Com* '" ' o �(J � ZLk t ipi E-mail Address: -t c iS� � Fax Number: NICET III number: a) 'W -1 Total number of new/relocated devices or sprinkler heads: L Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Day Telephone: LO6 3) 1 ZC7 Contractor's City of Tukwila Business License number: 1\ZZ 4, 1 -do cteNTc-- Orr k PERMIT APPLICATION NOS' Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: Print Name: Plan Permit App.doc 8/22/14 Day Telephone: Date�� TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 295490-0440 Site Address: 7100 Fort Dent Way Suite Number: Floor: 1 Tenant Name: Keurig New Tenant? ❑X Yes ❑ - No Property Owner's Name: John C Radovich Dev Co . Mailing Address: 2835 82nd Ave SE #S-1 Mercer Island, WA 98040 CONTACT PERSON -if there are questions about the submittal. Name: Matt Carlman City State Zip Day Telephone: 253-951-6005 Company Name: Fire Systems West, Inc. Mailing Address: 206 Frontage Rd N, Suite -C, Pacific, WA 98047 City State Zip E-mail Address: mattc@f iresystemswest . com Fax Number: Contractor's City of Tukwila NICET 111 number: Business License number: BUS 0994434 Total number of new/relocated devices or sprinkler heads: 2 Valuation of Project (contractor's bid price): $ 1,500.00 Scope of Work (please provide detailed information): Relocate 2 existing fire alarm notification device for tenant improvement. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time. for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER I R dTHORIZED AGENT: Signature: Date: 12/26/2017 Print Name: Matt Carlman Day Telephone: 253-951-6005 Plan l'ennit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. 71612 Site Address: -799-Fort Dent Way **PLEASE PRINT** King Co. Assessor's Tax No.: 2954900425 Suite Number: Floor: New Tenant? R] - Yes ❑ - No Tenant Name: Fuse Networks Property Owner's Name: John C Radovich Dev Co Mailing Address: 6840 Fort Dent Way, Tukwila, WA 98168 CONTACT PERSON -if there are questions about the submittal. Name: Matt Carlman Company Name: Fire Systems West Mailing Address: 206 Frontage Rd N. Suite C E-mail Address: MattC@firesystemswest.com City State Zip Day Telephone: 253-951-6005 NICET III number: 146053 Pacific City Fax Number: Contractor's City of Tukwila Business License number: WA, 98047 State Zip 253-735-0113 BUS -0994434 Total number of new/relocated devices or sprinkler heads: 5 Valuation of Project (contractor's bid price): $ $4,000 Scope of Work (please provide detailed information): add 5 new fire alarm notification devices PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 5/1/18 Print Name: Alex Kawalec Day Telephone: 253-833-1248 Plan Permit App.doc 8/22/14 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** //��, King Co. Assessor's Tax No.: /� Site Address: 1 r bp 1ii h l �� Suite Number: I ``/ D zA iiq0-04 �1a Tenant Name: ON i2 -..P.010-3 L Property Owner's Name: \©L\ C Mailing Address: 7_61 CONTACT PERSON -if there are questions about the submittal. Name: LA/`` t'L o c Company Name: C - r' Mailing Address: E-mail Address: Floor: New Tenant? Qf - Yes ❑ - No Y'"C.11_.et- 15\L-. City State Zip Day Telephone: 2_06 �C7L�'L U� f\ S , Sl. L j/51 �bZ 5 -6 �(� e_T&\& I -41Fax Number: 36 6 l S retk C1 i Contractor's City of Tukwila Business License number: NICET III number: -C Total Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): P p D S X10 CArt(... L b Co () ci• f ` `CALL Q.z< : STi \ ` C-xv � CSara": t%� ¶ S PERMIT APPLICATION NOTES V Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE R AUTHO IZED AGENT: Signature: —� Date: Print Name: 0A11--S-1U n�f Day Telephone: � I 3415 -3 -- IF Plan Permit App.doc 8/22/14 TFD FP Form 8 44iitt"44 SITE LOCATION Site Address: Tenant Name: 1 A 0 J L 100 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 79oT YJT r&\ PATO P" 232319 TUKWILA FIRE King Co. Assessor's Tax No.R CINCH �D y(..(� Floor: ' Suite Number: )o 0 New Tenant. - Yes ❑ - No Property Owner's Name: O"\ C 4,1).( CT b...V Mailing Address: ZnS I �j ' SLC 1� w,Nct`c L( o City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Litt",, -t c. iY\-P-/\ Company Name: f t /--S---c ZL -c_ Ft('-- �` Mailing Address: fr - f 1— 21 ,/ \VL._ -c(_. r � City ; 1 , C oil, StatY Zip E-mail Address: c (-5�� L`tYN,S� c ('e- l�/tY' 1� Fax Number: 3 CO 4' ( 2-C6-00 ^O P '"C Contractor'sCity cense number: NICET III number:`� Business cense number: Day Telephone: ? CC 5-11 3c\S 3 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ b Scope of Work (please provide detailed information): 14 O PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE : : ' AUTHORIZED AGENT: Signature: - Date: &C IS- (I Print Name: r. f' ti Day Telephone: 2_06 S 1 I 3S5 -5 --- Plan SS5---Plan Permit App.doc /22/14 TFD FP Form 8 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION King Co. Assessor's Tax No. 2954900440 Site Address: 7100 Fort Dent Way Suite Number: 10 0 Floor: l S t Tenant Name: Tabor New Tenant? Yes ❑ - No Property Owner's Name: JCR Mailing Address: 2835 82nd Ave SE, S-1 Mercer Island WA 98040 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Matt Carlman Day Telephone: 253-951-6005 Company Name: Fire Systems West Mailing Address: 206 Frontage Rd N. Suite C Pacific WA, 98047 City State Zip E-mail Address: MattC@firesystemswest.com Fax N umber: 253-735-0113 NICET III number: 146053 Contractor's City of Tukwila BUS -0994434 Business License number: Total number of new/relocated devices or sprinkler heads: 9 Valuation of Project (contractor's bid price): $ 4500 Scope of Work (please provide detailed information): Improvement. Install New Fire Alarm Notification Devices for Tenant PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHa GTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AUTHORIZED AGENT: r C c �,� 219 Signature: Date: 09/23/2019 batt Carlman TUKWILA FIRE253-951-6005 Print Name:Day Telephone: Plan Permit App.doc 8/22/14 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Wood -Richardson 7100 Fort Dent Way #225 Permit No.: 17-S-236 Date: December 12, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Flexible sprinkler hose bends shall not exceed the maximum radius permitted by the listing. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Therapeutic Associates 7100 Fort Dent Way Suite 220 Permit No.: 16-S-238 Date: November 16, 2016 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 21h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructedlnon-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Washington Youth Soccer 7100 Fort Dent Way Suite 215 Permit No.: 14-S-031 Date: February 24, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 % inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 fl.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. All code references are NFPA 13, 2010 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Keurig Green Mountain 7100 Fort Dent Way Suite 160 Permit No.: 18-S-029 Date: February 6, 2018 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. A FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Tabor 7100 Ft. Dent Way Suite 100 Permit No.: 19-S-211 Date: November 8, 2019 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' off the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'h inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath aN obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Weld stamps shall be inspected on the ground, before pipe is hung. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterilow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2019 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Fuse Network 7100 Fort Dent Way Suite # 140 Permit No.: 18-S-104 Date: May 24, 2018 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 "for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 21/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. I • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2016 Edition. FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Keurig Green Mountain 7100 Fort Dent Way Suite 150 Permit No.: 17-S-019 Date: January 31, 2017 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ` of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. CORRECTION NOTICE/REINSPECTION FEE "� Inspector: T 4 `,S'3 Permit number: DI 9 -02-2- 2— TUKWILA FIRE MARSHAL'S OFFICE Office: 206-575-4407 Fax: 206-575-4439 Email: Fire Marshal@tukwilawa.gov Business Name:•1 3 Type of Inspection: r—�� Location Address/� 6 )14,1- P1/ Date : z �I ( i f 11 Contact P,erson : '>CL(/vC VAScAvr+ gT'tO(. Phone No. :\ Sc (206) 96z - 0U $J ACTION REQUIRED : 1 Sr 2.4° loom___ 4//4-70 /V /-/e ,moi f -A- s. ai syp�. N FrP\ 72 CORRECTION OF . , ABOVE ITEMS ARE REQUIRED BY : J I�+J ( 2-©2 FAILURE T Signature: Billin ' ming Address : ,r/Y RESULT IN THE ISSUANCE OF A CRIMINAL CITATION/TICKET. Attn: Company Name: Address: City: State: Zip: ❑ A $100.00 Reinspection Fee is required. You will receive an invoice from the City of Tukwila Finance Department. ❑ Ticket Issued. Citation # Correction Notice Reinsp Fee2.doc Revised 6/17/14 T.F.D. Foran F.P. 100 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 9-QZZZ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Projects-- /�,�� Type of Inspection: Nr.& ,iii-- ��4--i Address:___,Contact Suite #: lOb -1----bar ba....41— k (itI ItcYPhone Person: Special Instructions: No.: Approved per applicable codes. COMMENTS: Corrections required prior to approval. /1-1444r‘ /A/Creo-%-1 ‘,01eAgife-, ////112-"" /11/ 01''ts-e-e--74?/1-1 65-77,44, I fits_c 01J Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:ZL_Date: /21////1 Hrs.: 4.6 _ , / n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ,47-f- I7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: /60r f Sprinklers: Type of Inspection: Address:Contact Suite #: 7/ij o/t-i , M Person: 6/41d Special Instructions: A Permits: d fl Phone No.: e(TZ-0a(5--f Approved per applicable codes. COMME • nCorrections required prior to approval. epp&OL Needs Shift Inspection: f Sprinklers: Fire Alarm: Hrs.: Hood & Duct: Monitor: Pre -Fire: Permits: d fl Occupancy Type: Inspector: '1 (Nl f ..4,k L Date: 4 -74,11C1 Hrs.: 1< < $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 2 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1J19 - z22, ,/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: (4t77 /i6frVs l NS T- r�-Z4fQd Type of nspection: / •luxur Address:Cona Suite #: 7/ 0 0 4.---i- ���, "'0- e rson: t� Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval.` COMMENTS: (4t77 /i6frVs l NS T- r�-Z4fQd Monitor: Pre -Fire: Permits: Occupancy Type: 11( 0})- /67 — 41/ Ai0114e1 /#41ZCIAte— 21,--e./ �, ate,., t _ -, �, IL� _• Al . . Led Ea_ 1–,Y • _. •, al, . 4.. I' - 2 I W Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: c. Date: ///7-7/ i Hrs.: $100.00 REINSPECTION FEE REQUIRED. 1You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 n. w • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit �I9-Q1-22 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:— 7—b a r-- Sprinklers: Fire Alarm: Hood & Duct: Type of Inspection: 0//,QA 5/p Address:erso Suite #: 7) -_1 1�1' 0„�" 0 a Cont ct Person: Special Instructions: Phone No.: 0/ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: — /01/6MVE Occupancy Type: , S r-1 1.4ak r fliws dam+ s')- )ra/ 0/ %a caueA ` fry f ( ,A /. v 740104-7 e770'11 j G w �1 4/20.-174--%L Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: , ` Inspector: ,it_ Alf 63 Date: 11//2//7 Hrs.: .. 6 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 e Z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit T)teb — d?13 12 -F —O?9 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:���� l U�,kiJur (4 Date: d ih S Type of Inspection: P5v'X. A/A-rtivt Address:10 Suite #: /100 .r+ �,-� Contact Person: Special Instructions: /-4,4„1„, n �I- Phone No.: Approved per applicable codes. I I Corrections required prior to approval. COMMENTS: Ad0fgal A —OQV1C 14/5 54n11.c Dtil1 Needs Shift Inspection: h/fri 53 Date: d ih S Sprinklers: \{.t4 Fire Alarm�r,aS Hood & Duct: Monitor: /-4,4„1„, n �I- Pre -Fire: Permits: Occupancy Type: 2? 1 Inspector:' . h/fri 53 Date: d ih S Hrs.: /. Q $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:S� i vv16 4 Type of Inspection: 5 (NGat- Address:Contact Suite #: 77 u Mgr Asill-- k e y Person: Special Instructions: pi 40 ( Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6 7730 C_/e-r2- etilINfr/%rl, F Net- 1'�L Needs Shift Inspection: Sprinklers: ye 5 Fire Alarm: .e.,S Hood & Duct: Monitor: /�yyi c �- l Pre -Fire: Permits: Occupancy Type: R Inspector: fin c Date: g%fj $ Hrs.: n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Di -KV/ ie -s- O 2cj' PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ZeZ(g/6 Type of Insion: /74- — Ca vo., — /./,<1-(' Address: � Suite #: ?/UO Orf 00_�� /CV Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ifmc_ i/) /ivpE-y i Perla, Fire Alarm: yiS Hood & Duct: Monitor: Pre -Fire: Permits: //// -7521,47e Con6jo-b-IS Alw � , PCs D (c 77> .er - b',:z AfAZ-til -- ,42d Z ctGo 4 e / al - & c` - r..e niv09-/ _..e D 4 ,1 0(10:€ y fits_ AdaPi, /4.t e1` /V (2) .31‘-0“/ Needs Shift Inspection: N 0 Sprinklers: p..1 Fire Alarm: yiS Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: , Inspector: 7...._ /,‘f5-3 Date: 3/0 8 Hrs.: KA.I/ A, . 1 / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 l INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: �Ent(4 f g J Type of Inspection: ( -a--- Address: Suite #: WO 6 1. pLal"11—"70 Contact Person: (.449--n4 , Special Instructions: Permits: Phone No.: I I Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: ' ( ' Fire Alarm: Hood & Duct: Monitor: cP 2) CiAl7N167eN(2-ceg- q r�,evs Permits: -Tv6---/- ,9,J -- e6 ----"i7 Tz or---- openi S ,?-0 Q EI.1 0 op- L/�..rE Gt i.. i r -az- i opr -`- z d 77 (-ever-- AM r /9"fr--z7 x13 Needs Shift Inspection: te-e,j Sprinklers: ' ( ' Fire Alarm: Hood & Duct: Monitor: ! Pre -Fire: 7 Permits: Occupancy Type: Inspector: S--4--- Date: 242,4 K Hrs.: f $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit O2€3 11 —5 — PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: OoD R.k.c..L tuvr-Zi,,, Type of I spection: Co—J-4-x Address: -Th Suite #: � ( CZ ��- �1- Contact Person: Special Instructions: y.e.S Phone No.: Approved per applicable codes. nCorrections required prior to approval. COMMENTS: X. covw- Sp -- o \C-_ -Ft-ok I • mss Needs Shift Inspection: /ulA. Sprinklers: y ....liiS Hrs.: Fire Alarm: y.e.S Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Z Inspector: __ , - 3 Date: /z// y b) Hrs.: / .0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit by -Oa Ei 17-F- Wit( PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: //AA // r _ 2Dbet. C tv/iir Type of Inspection: Address:....„ Suite #: //0 fr",e,,,Itifr , ZZS Contact Person: Special Instructions: Monitor: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /-1/2`7L- AvSr 72q uael/el y Needs Shift Inspection: tv/iir Sprinklers: }/.Q'J Fire Alarm: Y p Hood & Duct: Monitor: -,-v,,. a- Pre -Fire: Permits: Occupancy Type: Z Inspector: ; cyki,f7 Date: / u/y/l ) Hrs.: p $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 V INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Icoieic,7 Type�n,,/s�p�ect� Address: /^ �-- Suite #: ��� f'`r ��� Conta Pers Phone No.: Special Instructions: Atco Approved per applicable codes. nCorrections required prior to approval. COMMENTS: F/4- -F t-1 479ea-dv Acti. firprz-ovt-- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 17)4 c Date: 2J124-/(7— Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit p11, -a -3w PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:�� f� Type of Inspection:' f1'<<j�l�tn//Ki /.44 -1 --- ntact Person. Address: Suite #: t00 4g" beir Special Instructions. "it, Phone No.: RIFproved per applicable codes. riCorrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: r/4 /(%6riit of4Nte--0 x77241 "s /,./ see -Z.6-- r r✓o T 3yni c 0 ("V 5 6E`S /n/ frl'/ft — . Occupancy Type: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: f--ivi s-4_ Date: 3/24117..._ Hrs.: • n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 fI� INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit j>110-634,4, PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 1Type ic (� �f t / & of Inspection: /f ov ic- ce-Ni,e__, Address:Contact PersonJ• ne:40 n frw7—_ Suite #: � &rot? j Special Instructions: 45D Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: S epiA bysn 144 R -O r 6 ec - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: F.744, 5-4-- Date: / A z Hrs.:' $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 V' INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: g710(1467 Type of�I,nr�s�pe ion:C�E� Sii"_ ` Address: Suite #: � Fvr00r t Contact Person: L4;iI 4P/7 --- Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: -4-1)0f) +-7\ifl 0,P z_tosv&-- Pcsiy2-47/\“-s 77-0-0/621-zirv-r- 1 - I__-, 4,(2,-, 0,12_ (2,---,Ty2A-7,-r- iug-----Am Asevr-- 1/4,4) Lin /N L—r•fria-11 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: r.744 S-4. Date: 224-ljq.-- Hrsi(: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 4F7/1._t�7 Sprinklers: Type of Inspection: Contact Person: "iAIZ.i 1'►ti Address: Suite #: 6-6F T t�M Phone No.: Special Instructions:20 Approved per applicable codes. Corrections required prior to approval. COMMENTS: --- 50 .v'1 - iru:fl - irk — E714 c—irz-Gz6r lc A (-( tA/15? — 61 -c -- Needs Shift Inspection: Sprinklers: Fire Alarm: ' Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: frill c• Date: (2/h 4'// Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Z INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 17-F- 00 (� DK, — 02`f Y PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: A4/fr / /- Fire Alarm: Type of Inspection: �/-� Address: Suite #: 7100 j/4---1 ii ,.- if Contact Person: Special Instructions: Phone No.: p( Approved per applicable codes. Corrections required prior to approval. COMMENTS: Aid / 5.9x4 &e- — 14(g Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspect -6: Z4 I-3 -3 Date: 2/121/ 1 Hrs.: 1 .. 0 j $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit JG -3-2313 1.16 -02`� PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: le/t/. it/ Sprinklers: y Type of Inspection: �� vW— Address:b Suite #: 7/c0 j rt-�, jo Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 04 � Coy.. r'` Gv/ TI,.c- ew)-sek4� 1?,41— /'t»-/ 3r09 -a- a�! f� or' /,,mss �.1/ �e 7.yeg744, 1-60 Coo& gp/% //gA--1 I — 7 . ,s4 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 929 3 Inspectdj ,Z(3 Date: i/ j'�J 7 Hrs.: %_ d $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 TUKWILA FIRE MARSHAL'S OFFICE Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshal@tukwilawa.gov 4 AV CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date /1/1211-9- Permit# Property Address 1` �•, ` � �; Suite # CZ-5— Cit. Z5— City TUKWILA Zip Code Name of Facility Occupied as Owner or Representative Installing Company VW..., 5 Installing Contractor's Address Z,CO qc C_- PO C.I' T WA -- Phone # 2553 331 &L ( Phone # City poi u ?, Installer's Name (PRINT) .AOUTY\ ► k \he, License and/or Certificate M[ L -NE Ru 3T General Contractor DU - Electrical Contractor FACP Equipment Manufacturer Ra01IOYUGs Model # qb7.„ This s}stem has been installed. pre-te. ted d and operates in accordance with the standards listed below and was inspected by J�0 VV\ l -Q� On (date ) Ltd,zI11- and includes the deices listed on hack. Circle all that apply: 0 NFPA 72, Chapter 1 2 4 5 6 7 and/or IFC SEC 907 n (/ NFPA 70, National Electrical Code, article 760 Manufacturer's Instructions Manufacturer's Instructions (" ther (specify ) ukwila Cit% Ordinance Numbers 2050. 2051 UL Central Station Monitor System is monitored by flOkINGV 5.. p s SIGNED Date t S., stern Firmware: Installed %ersion Checksum Date Initial program Installation Date Re%isions and Reasons Programmed by EQUIPMENT INSTALLED AND TESTED: Control Panel _ of _ Make/Model Manual Station _ of _ Make/Model Smoke Detectors _ of _ Make/Model Heat Detectors _ of _ Make/Model Duct Detectors of Make/Model A/V Devices 1( of Make/Model (Aikido c./ fSC e.... - Audio Audio Devices _'of _ Make/Model , • Visual Devices _ of _ Make/Model Auto Door Release _ of _ Make/Model Trouble Indictors _ of _ Make/Model Batteries Readings Battery Full Load Charge Generator of _ '. ' 112Iake/1VIode1 HVAC Controls of - • Mak"t/Model Fire Alarm Dialer _ of _ Make/Model Monitored by _ . • . , d. • Annunciator _ of _ Make/Model . •. ' r Sprinkler System. (Fire Alarm connections only) Water Flow Sw. _ of _ Make/Model Valve Tamper Sw. _ of _ Make/Model PIV _ of _ Make/Model t Elec. Alarm Bell of Make/Model Automatic time Delay of Water Flow Alarm seconds. None Installed Do you meet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes No Test of alarm System on emergency power, satisfactory? Yes _ No Test Witnessed by Title Date • Comments • Fire Alarm Certilicate.doc ReN,i sed: 6/17/14 TED FP Form #1 10 TUKWILA FIRE MARSHAL'S OFFICE Phone: 206-575-4407 • Fax: 206-575-4439 • Email: FireMarshalCtukwilawa.gov 4,44*A"ZtvCONTRACTORS NLATERI.AL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Wats Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date 3– Permit # 1'7— F"O/ Z Property Address /6O T ✓j4 ��'' o/ Suite # Cit. TUKWILA lip Code CNIgo Name of Facility 1 OZ ► e.)114 - 1 r. Occupied as Keu>n ev-r ee.r /46vx–ituis p 61t14 SIO) 1Y\i� Owner or k� rzentati�e /�" � �,,�Phone # �y / 3 Installing Company ''Iz Sy$�a -. Coe -a -f— Installing Contractor's Address 20 (i• I....Y:i/4-600-V £S Lt Citi i'u//yy d e j.G Phone # 2C3 t 3 3 n_scs Installer's Name (PRINT) J41*_rari /C4%/it. License and/or Certificate A/L.)' E, APTS/5r– General 7 75General Contractor /1« S►litd"G41.--i Gt./ea- I--Electrical Contractor /1-4) FACP Equipment Manufacturer /S'ut /SO4,117C Niodel # r ?97Z ------ -re 777/.r This system has been installed. pre -tested and operate; in accordance with the standards Iistedbelow and was inspected On (date) 2—Z3--/7– and includes the deices listed on hack. Circle all that apply: NI -13A 72. Chapter 1 2 4 5 6 7 and/or IFC SEC 907 8NFPA 70. National Electrical Code. Article 760 Manufacturer's Instruction: Manufacturer's Instruction; Other K;pecif} Tukwila Cit.. Ordinance Number, 2050. 2051 UL Central Station Monitor ( 151 s., stem i; monitored h` , 1i ik can f 1 he., S [GNED e Date System Firmware: Installed version Checksum Date Initial program J, Installation 'Pre,Stidier6 (, t Re‘i;ion, and Reason. Date Programmed h. EQUIPMENT INSTALLED AND TESTED: Control Panel Manual Station Smoke Detectors Heat Detectors Duct Detectors of of of of of A/V Devices O of Audio Devices of Visual Devices of Auto Door Release of Trouble Indictors of Batteries Readings Battery Generator of HVAC Controls of Fire Alarm Dialer of Monitored by Make/Model Nlake/Model Make/Model Make/Model Make/Model Make/Model ti/%LtthLe---- Make/Model Make/Model N[ake/Model Make/Model Full Load Charge Make/Model Make/Model Make/Model Annunciator of N[ake/Model Sprinkler System. (Fire Alarm connections only) Nater Flow Sys . Valle Tamper Sm.. PIV Elec. Alarm Bell of of of of Make/Model Make/Model Make/Model Make/Model Automatic time Delay of Water Floe Alarm seconds. None Installed [)o `ou meet audthle/risible requirements of HVAC 51-20, IFC SEC 907., and/or NEPA 72 Chapter 67 No fest of alarm Sy stem on emergency poser, satisfactory? Test V [messed b‘ W1/4 Title Comments: No ? C� . p."- ,CCLJ)ate 3 11"- \ I arm 1"- \farm Certificate dna ised Fi/17 I.1 TFD FP Form #I lu c 1 TUKWILA FIRE MARSHAL'S OFFICE Phone: 206-575-4407 • Email: FireMarshal a tukwilawa.goy CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date Co/,/ /41 Property Address 7/9,10 City TUKWILA Permit /'‘ -..46cfl ;Z -T- -De wf y Name of Facility fo9..7 '3 1:-,v j Occupied as Suite# IYch Zip Code 9 `6I Co 41) tie.7 L.) e-12-1 Owner or Representative Phone r Installing Compamv / iRF' SYS ,c„r C./ CS r Installing_ Contractor's Address (... f Ao'�s?�ifj� 2� /v'/ fuirN-C City 7/4crs2ic Phone 2-M ?. 3 — -VS--> 4'Y Installer's Name (PRINT) fN(Ak2c,,.) rhie vcr License and/or Certificate M u Wim' t c Ll Ci General Contractor Electrical Contractor 1712[= Sy3r&rts L -Xe r I S;" Cw►S W( -"ST FACP Equipment Manufacturer 17_,>,b cm,Ac S Model This s), stem has been installed, pre -tested and operates in accordance with the standards listed below and was inspected b\ M - CAluw..,h.) Q. Ir./tee- rjsr -Afs 41-6-s '— On (date) (p/c//and includes the devices listed on back. Circle all that apply: NEPA 72, Chapter 1 2 4 5 6 7 and'or IFC SEC 907 NEPA 70, National Electrical Code. Article 760 Manufacturer's Instructions Manufacturer's Instructions Other (specify) Tuk'.ila Cit. Ordinance Numbers 2050. 2051 LI_ Central Station N1 itor Sstem is monitored b‘ SIGNED Sstem F irmw, ark: Installed version Initial program Installation Checksum Date L/G//5r Re\ inions and Reasons Date Date Programmed b‘ EQUIPMENT INSTALLED AND TESTED: Control Panel of Make/Model Manual Station of Make/Model Smoke Detectors of Make/Model Heat Detectors of Make/Model Duct Detectors of Make/Model ATV Devices 3 of 3 Audio Devices _ of Visual Devices of _ Auto Door Release of Trouble Indictors of Batteries Make/Model Lahee_toc"... Make/Model Make/Model Make/Model Make/Model Readings Battery Full Load xcc-c.4%. Generator Generator of Make/Model HVAC Controls of Make/Model Fire Alarm Dialer of Make/Model Monitored by Annunciator Charge of Make/Model _. Sprinkler System. (Fire Alarm connections only) Water Flow Sw. of Make/Model Valve Tamper Sw. of Make/Model PIV of Make/Model Elec. Alarm Bell of Make/Model Automatic time Delay of Water Flow Alarm seconds. None Installed Do you meet audible/visible requirements of WAC 51-20, IFC SEC 907., and/or NFPA 72 Chapter 6? Yes No Test of alarm System on emergency power, satisfactory? Yes No Test Witnessed by Title Comments: Date Fire Alarm Certificate.doc Revised: 6'1714 TFD FP Form #1 10 La(' '' ii U�Cw i�a t' i Fcs 5-1S �p,S. L (o sO CONTRACTOR'S MATERIAL AND TEST CERTIFICATE FIRE NJARM AND FIRE DETECTOR SYSTEMS 2 '214 1.-71,../.4140"' PROCEDURET-FIECTOR DATE lk/2, Pf Upon completion of work, inspection and test shall be made by the contractor's representative and witnessed by local fire department. All defects shall be corrected and system left in service before contractor's men finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for inspecting authorities, owner and contractor. It is understood the owner's or representative's signature in no way prejudices any claim against contradtor for faulty material, poor workmanship or failure to comply with inspecting authority's requirements or local ordinances. Name of Facility Cork 424 MC Property Address 7?tots rort itiaNf L.141. iv‘lpti-l4. i, Occupied as / Zip Code Installer's Firm Name g Q k,J.(le co,L0,1147 Address of Installer PO ac„c '1cDt4 04,1 S 8 Electrical Contractor's License Number f i ATC% 71- 044 QF Wireman's Certification Number` URri4y-1y 4L1' Tests witnessed by 44 Seel -4 Title 4 Date LVIS141 to certify that this fire alarm system has been erviced (circle one) in accordance with the standards e• by the local authority' having jurisdiction and is consistent with NFPA Fire Alarm Standards. A. Name of Firm SNIAlet.1j4e„ faON ry Phone y sFr S- (t`clo B. Mailing Ad • ess AD Aoy, 2 i1 / C. Name (Signature of Firm Official) Qe c> 4 . ca6S2 it -14444 Title ,ck Date //q95 Additional explanations and comments 20 2 41.4SI) AQUIPMENT INSTALLED AND T.. .ED TYPE OF EQUIPMENT NUMBER OF UNITS TEST,BH TESTED OAT" r SATISFACTORY CHECK MODEL AND MANUFACTURER Yes No N/A Panel t ....«Control y/I cher ✓ 4,14-i & Manual Station 11 Heat Detectors Smoke Detectors 41; II/chi) Audible Alarm Devices 21 Visual'' Alarm Devices _A Code Transmitters Automatic Door Releases Trouble Indicators ohI�, Master Alarm Box Batteries 11/191 Charger 2 liter ” Generator Ventilation Control 4 1. '1 SN Fire Department Interconnection Central Station 1/1/6/151 t/Interconnection Exterior Sprinkler Electric Alarm Bell i 'IV Siti Sprinkler Water Switch / /5� pit `/Flow Sprinkler Gate Valve Supervision Switch 2 �/ 1/%5 i% Annunciators I Y/S-rn Automatic Time Delay of General Alarm# Minutes. None Installed 0 Test of alarm system on emergency power, satisfactory Yes B' No 0 Local Fire Department Acceptable Yes I/No ❑ Comments: City of Tukwila Fire Department OCT 9nrIc TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name � �? r� Address , ..> -) F 49e Permit No. Retain current inspection schedule Needs shift inspection Suite # %(- Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Occupancy Type: Authorized Sigrikure Date Final Approval Frm Rev. 5/2/03 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 City of Tukwil Fire Department JULF] 3 0 1999 John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name /(7(thipt•Cdc7 i 14- Te -S Address /v u r()leT Thomas P. Keefe, Fire Chief Permit No. -'v/ C% L� Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: A -o ?r r / 1/ !a t_,4 (/ 1 L7,2 Authorized Signature FINALAPP.FRM 7,/32/2 Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Project Name TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM GCS APR 2 3 1994 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No.1B-�ac:;.s. Address -% (O D C"� Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Ac TV' Pre -Fire: Permits: 4\ ‘5 Authorized Signature Date FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department APR 1 5 1999 John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name 1FDck TV Thomas P. Keefe, Fire Chief Permit No. Address ---1‘00 � D* DST Retain current inspection schedule Needs shift inspection Sm kc 7,3-00t Suite # � Approved without correction notice )(\ Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: A1acw. Utrker 5/ Authorized Signature FINALAPP.FRM Rev. 2/19/98 4\15\ Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 si )4\ckoi TUKWILA FIRE DEPARTMENT A ,3 Co FIRE PREVENTION BUREAU ColvIAR, (206) 575-4407 CORRECTION NOTICE/REINSPECTION FEE 4AlEkn BUSINESS NAME: D VN(c\c' .. DATE: ADDRESS: -1 l r3U A. O `jBLDG: SUITE: N APT- TYPE OF INSPECTION:{nW L INSPECTOR: 5 to BLDG. PERMIT #:kflajebiC CONTACT PERSON: PHONE: ACTION REQUIRED:1 ` ` Q.-�_•Y'l Pi 1.j_ Tr-� 5 !\✓1ri)til !� c\ L� V ek\\C fS.51ky.4..t. - CORRECTION OF THE ABOVE ITEMS ARE REQUIRED BY: 41A Z°1�'� A Reinspection Fee is required and must be received by the $40.00 Tukwila Fire Department, 444 Andover Park East, Tukwila, Wa. 98188 prior to reinspection. Make checks payable to the City of Tukwila and provide the YELLOW copy of this notice with payment. FAILURE TO PAY the reinspection fee within seven 7 days may result in the issuance of a citation for Failure to Comply. For Office Use Only: Date Paid: Receipt #: File Code: W -Finance Y -File P -Contractor WP:CORREFEE.FRM T.F.D. Form F.P. 100 FIRE PROTECTION, INC. PO SOX 12642 MILL CREEK WA 98012 (4251 290-9600 OR 1-100-681-1125 FAX (4251 353-4546 May 19, 2010 City of Tukwila -PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed plans for FIRE ALARM SYSTEM. The system has been designed per NFPA 72, 2002 edition requirements as well as WAC, IBC, IFC 2006, NEC current and your additional requirements. Fire Protection, Inc. will add/relocate devices per plan to the existing system. The building is fully -sprinkled. The system shall monitor by zone activation as well as separate trouble signals. Monitoring shall be provided via UL listed Central Station, The Alarm Center LACEY, WA., over 2 analog lines via a built in DACT. Audibility shall be in compliance with NFPA standards with a 10 inch bell located on the outside of the building in the top 25% with a 117 candela strobe facing the first in -coming FIRE DEPARTMENT vehicles for easy building location. Interior DB shall be 75 DB minimum throughout. A full service and monitoring agreement is in force for the proper service and maintenance per NFPA requirements. All systems shall be UL certificated and placard. A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. 1730 Gibson Rd. Everett, WA 98204 WSCL# FIREPI*021ML UL CERT #608242-002 JOB SITE ADDRESS State Farm 7/0440* Fort Dent Way 24P��— -2l,o Tukwila, WA. APPROVED UL MONITORING COMPANY Alarm Center, Inc./FPI 4300 3rd Ave. SE Lacey, WA 800-429-0991 UL CERT #902799-02 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring; Service; Testing; Runner Serv; Fire Protection, Inc. UL Cert; Fire Protection, Inc. ADIENT TEMPERATURE S No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AMBIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per DBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify UL listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re -dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, (no notification circuits shall activate.) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds. Low air shall activate at 251bs, causing for a supervisory signal. A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause alarm. Shorts on PIV, tamper and Hi -low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal. Should you have any further questions, please feel free to contact me directly. Roy L. Cats Project Manager CFPS #1473**NICET-4 #09786**SFD #SCP -9955 CITY OF REDMOND DESIGNER OF RECORD #B-0-002 SILENT 5495 Pc,..er Expander Ca'cu!a;:ons Version 02 lig Panel ID: 15495 Location: 'Fire Alarm Control Room — Global Project Values: Project Name: Project ID: Prepared By: Date: State Farm 'Roy L. Cats 5/19/2010 Standby Hours: Alarm Mins: Derating Factor. Voltage Drop Waming Threshold % . Model: 5495 Power Expander ' Volts: 24 VDC 60 5 1 1.2 10 Max NAC Current 3.0 Amps Max Panel Current 6.0 Amps Ckt.# Circuit Name __5495__ _,_ j 5495 Pwr Module Current Draw Wire AWG Ohms Per Length(ft) Actual Volts © Standby Alam' & Type 1000 Ft. One -Way Ohms EOL 1 1 0.0751 0.205 1 NAC #1• • NAC #1 0.000 0.652 #16 Solid 4.02 250 2.01 19.09 NAC #2 Not Used 0.000 0.000 #16 Solid 4.02. 0.00 20.40 NAC #3 Not Used 0.000 0.000 #16 Solid .. 4.02 .0:00 20:40 NAC #4 Not Used 0.000 0.000 #16 Solid . 4.02 0.00 20.40 Aux 5495 Aux Power Out 0.000 0.000 #16 Solid 4.02 0.00 20.40 Total Standby Cunent (Amps). 0.075 0.857 Total Alarm Cunard (Amps) Alarm Time In Minutes / 60 (5 Mins) Total Alarm AH Required Standby Time In Hours TotalStandby AH Required Total Combined AH Required 60 0.083 4.500 0.071 4.57 Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 5.49 12VDC 7Ah Batteries to be used Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Configure Circuits CPrint Page Circuit Configuration Project Information Project Name: State Farm Prepared By: Roy L. Cats Project ID: 0 Date: 5/19/2010 Ckt. Number. NAC #1 Panel ID: 5495 Ckt Name: NAC #1 Max Circuit Current 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor P2/PC2 Hom/Strobe (30cd) 0.000 0.116 0.000 0.464 2 System Sensor S/SC Strobe (30cd) 0.000- 0.094 0.000 0.188 Unused 0.000 0.000 ' 0.000 0.000. Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.652 Ckt. Number NAC #2 Pane l ID: 5495 Ckt. Name: Not Used Max Circuit Current 3 Amps QtY Device Current Draw Each Current Draw Total Standby Alarm Standby Maim Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 ' 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0:000 Totals 0.000 0.000 Ckt. Number. NAC #3 Panel' ID: 5495 Ckt. Name: Not Used Max Circuit Current 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt Number. NAC #4 Panel ID: 5495 Ckt Name: Not Used MaxCircuitCurrent 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 STATEWIDE SECURITY FIRE ALARM EQUIPMENT SUBMITTAL FOR FIRE DETECTION SYSTEM FORT DENT III Therapeutic Associates Tenant Improvement TUKWILA, WASHINGTON July 14, 1999 A) D9412 Radionics 9412 Control/Communicator B) D8109 Radionics Auxiliary Fire Enclosure, Red C) D928 Radionics Dual Phone Line Switcher D) D122L Radionics Dual Battery Harness E) D192C Radionics Indicating Circuit Supervision Module F) D8132 Radionics Battery Charger Module G) D8004 Radionics Transformer Enclosure H) D1256 Radionics Fire Command Center I) D8125 Radionics Popex Module, Point Bus J) D411 Radionics Synchronization Module, 2 wire K) D443 Radionics 24V, Bell, 10" Shell L) D559S Radionics 24V, Synchronized Mini Horn Strobe, 15/75 cd M) D572S Radionics 24V, Horn Strobe, 110 cd N) D548S Radionics 24V, Strobe, 110 cd 0) WH114911 Wheelock 24V, Exterior Strobe P) SK5395 Silent Knight Super. Bell Circuit Pwr. Supply Prepared By: Statewide Security P.O. Box 2019 Redmond, WA 98052 Phone: 425-558-4640 Fax: 425-558-1290 P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 STATEWIDE SECURITY FIRE ALARM CALCULATIONS BATTERY BACK-UP TIME FORT DENT III Therapeutic Associates Tenant Improvement TUKWILA, WA July 14, 1999 FIRE PANEL: Silent Knight, SK5395 Supervised Bell Circuit Power Supply SK5395 75 MA (average current) x 24 Hours = 1.8 AMPS Subtotal 1.8 AMPS Horn/Strobes 1 @ .283 AMPS (average current) = .283 AMPS Strobes 2 @ .163 AMPS (average current) = 3.42 AMPS Subtotal = 3.70 AMPS Divided x 12 (5 min. ring) _ .31 AMPS Total Load 2.11 AMPS System has two (2) 12V, 7 A.H. Batteries in series for 7.0 A.H. Available @ 24 Volts. P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 STATEWIDE SECURITY Fort Dent!!! Therapeutic Associates Tenant Improvement Voltage Loss Calculations July 14, 1999 All conductors are 14 Ga. Solid copper core (12.9 constant), plenum rated, circular mil. Spec. of .4110 Horn/Stobe circuit #1: Not Used Horn/Strobe circuit #2; 6 Devices @ .163 Amperes ea. = .978 Amperes x 2(105'), x 12.9 divided by 4110 = .64 Volts of loss Horn/Strobe circuit #3: 1 Devices @ .177 Amperes ea. and 6 Devices @ .163 = 1.15 Amperes x 2(112') x 12.9, divided by 4110 = .81 Volts of loss. Horn/Strobe circuit #4: 9 Devices @ .163 Amperes ea. = 1.47 Amperes x 2(137'), x 12.9 divided by 4110 = 1.26 Volts of loss. P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 strnOJi0 aln6ijuoO Minimum Battery AmpHours Required Multiply By The Derating Factor Total Combined AH Required Total Standby AH Required Standby Time In Hours Total Standby Current (Amps) x Z n 1 NAC #3 1 NAC #2 Z n # it CT Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 15495 Aux Power Out 5495 Circuit 4 5495 Circuit 3 5495 Circuit 2 5495 Circuit 1 5495 Pwr Module 1 1 N k V 3 N O j O CS) Co O N A 0.075 0.000 0.000 O O 0 0.000 0.000 0.075 — Global Project Values: 1 Project Name: 'Mindful Therapy Standby Hours: 24 Project ID: Alarm Mins:1 5 Prepared By: Justin Gronberg Derating Factor: 1.2 Date: 1/9/2017 Voltage Drop Warning Threshold % 10 0 O co CJ 0 O— co W — - J 0 O O O- 0 N N 0 O 0 0 0 O 0 0- 0 Cr) co 0 N O CT Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Total Alarm AH Required Alarm Time In Minutes / 60 (5 Mins) Total Alarm Current (Amps) 4t N 0 a 4t A 0 a 4t N 0 a 4t N CO as 4t A 0 1.59 N in N) -a (T CO -a in CO N (T N r 250 O O O O O O O O O 0.00 -+ N co 20.40 1 1 20.40 1 N O A 0 20.40 1 _, CO in C) O O O 0 O O O 0 O O 0 0 O O OJ 0 A N 0 SILENT KNICIIT Circuit Configuration Project Information Project Name: Mindful Therapy Prepared By: Justin Gronberg Project ID: 0 Date: 1/9/2017 Ckt. Number: NAC #1 Panel ID: 5495 PS2 Ckt. Name: 5495 Circuit 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.352 1 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.116 2 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.132 1 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.091 0.000 0.000 Totals 0.000 0.691 Ckt. Number: NAC #2 Panel ID: 5495 PS2 Ckt. Name: 5495 Circuit 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: NAC #3 Panel ID: 5495 PS2 Ckt. Name: 5495 Circuit 3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: NAC #4 Panel ID: 5495 PS2 Ckt. Name: 5495 Circuit 4 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor P2/PC2 Horn/Strobe (110cd) 0.000 0.221 0.000 0.221 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.221 /." STATEWIDE SECURITY FIRE ALARM EQUIPMENT SUBMITTAL FOR FIRE DETECTION SYSTEM FORT DENT III University of Phoenix Tenant Improvement TUKWILA, WASHINGTON July 1, 1999 A) D9412 Radionics 9412 Control/Communicator* B) D8109 Radionics Auxiliary Fire Enclosure, Red* C) D928 Radionics Dual Phone Line Switcher* D) D122L Radionics Dual Battery Harness* E) D192C Radionics Indicating Circuit Supervision Module* F) D8132 Radionics Battery Charger Module* G) D8004 Radionics Transformer Enclosure* H) D1256 Radionics Fire Command Center* I) D8125 Radionics Popex Module, Point Bus* J) D411 Radionics Synchronization Module, 2 wire* K) D443 Radionics 24V, Bell, 10" Shell* L) D505S Radionics 24V, Synchronized Horn Strobe, 110 cd A M) D515 Radionics 24V, Remote Strobe, 30 cd A N) WH114911 Wheelock 24V, Exterior Strobe* 0) SK5395 Silent Knight Super. Bell Circuit Pwr. Supply A * Indicates units/devices installed in original permit for "Base" installation permit #99F069, completion date 04/15/99. A Indicates unit/devices installed for University of Phoenix Tenant Improvement. Prepared By: Statewide Security P.O. Box 2019 Redmond, WA 98052 Phone: 425-558-4640 Fax: 425-558-1290 P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 Fort Dent 3 University of Phoenix Tenant Improvement Voltage Loss Calculations All conductors are 14 Ga. Solid copper core (12.9 constant), plenum rated, circular mil. Spec. of .4110 Horn/Stobe circuit #1: 6 Devices @ .236 Amperes ea. = 1.41 Amperes x 2(120') x12.9 divided by 4110 = 1.06 Volts of loss. Horn/Strobe circuit #2: 4 Devices @ .236 Amperes ea. + 2 Devices @ .17 Amperes ea = 1.28 Amperes x 2(137') x 12.9 divided by 4110 = 1.10 Volts of loss Horn/Strobe circuit #3: 6 Devices @ .236 Amperes ea. = 1.41 Amperes x 2(135') x 12.9 divided by 4110 = 1.19 Volts of loss. Horn/Strobe circuit #4: 6 Devices @ .236 Amperes ea. + 1 Device @ .17 Amperes = 1.58 Amperes x 2(118') x 12.9 divided by 4110= 1.17 Volts of Toss. FIRE ALARM CALCULATIONS BATTERY BACK-UP TIME FORT DENT III TUKWILA, WA FIRE PANEL: Silent Knight, SK5395 Supervised Bell Circuit Power Supply SK5395 75 MA (average current) x 24 Hours Subtotal Horn/Strobes 22 @ .283 AMPS (average current) Strobes 3 @ .135 AMPS (average current) Bell 1 @ .056 AMPS (average current) Subtotal Divided x 12 (5 min. ring) Total Load = 1.8 AMPS 1.8 AMPS = 6.22 AMPS = .405 AMPS = .056 AMPS = 6.625 AMPS = .552 AMPS = 2.35 AMPS System has two (2) 12V, 7 A.H. Batteries in series for 7.0 A.H. Available @ 24 Volts. 1 Archer Cori structicork Inc _ 0 7855 South 206th St Kent, WA 98032 Date 07/15/99 Job: UOFPHON2 PROJECT INFORMATION Job_ UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Occupancy Ordinary Hazard Group I Density 0.15 gpm/sq.ft. Area of Operation 1500 square feet Area per Sprinkler 16X16 SPACING Authority having Jurisdiction_ _ NFPA-13 Hose 100.0 gpm Inside Hose, 100.0 gpm Outside Hose System type_ _ Wet Water Supply _ 155.00 psi Static, 105.00 psi Residual @ 1671.0 gpm Sprinklers _ _ Large Orifice CALCULATION SUMMARY Demand 97.27 psi @ 455.8 gpm @ B.O.R. 101.36 psi @ 655.8 gpm @ Supply 146.14 psi available @ 655.8 gpm Demand is below curve by 44.78 psi Notes: L Archer Construction Inc. Description of Fitting abbreviations Code .Description T Tee E Ninety degree elbow VE Victaulic ninety degree elbow B06 Backflow: Febco Backflow Model 805Y Dbl. Check Valve Assy. GV Gate valve Description of Other abbreviations Code Description AO Arm -over DR Drop BL Branch Line CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction PV Velocity Pressure -.5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length uvr rnuty 1 No. Code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DR1 A01 A02 A03 BL1 BL1 BL1 BL1 BL2 BL2 BL2 BL2 CM1 CM1 CM1 RI1 BU1 RI2 UG1 UG1 ui/i3/i 3:tuam x Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT 7100 FORT DENT WAY Raw data previous Diam Length Kfacl 1.104 2.0 11.4 1.104 2.5 DR1 1.104 3.0 DR1 1.104 2.0 DR1 2.154 16.0 A02 2.154 16.0 A02 2.154 16.0 DR1 2.154 7.0 A03 2.154 16.0 A01 2.154 16.0 AO1 2.154 16.0 DR1 2.154 7.0 A03 3.352 16.0 BL1 3.352 29.0 BL2 3.352 37.0 3.352 11.5 CM1 3.352 217.0 RI1 4.352 11.5 BU1 8.270 70.0 RI2 8.270 0.0 .7i1CCC OI DENT 3 SECOND FLOOR TUKWILA, WA. to any calculations Kfac2 Press Elev Hose HW Vel Fittings 11.35 -2.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 A02 0.00 0.00 A02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 11.50 0.00 0.00 0.00 11.50 0.00 0.00 0.00 0.00 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 100.0 100.0 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 140 140 32 32 1E,1T 32 1E,1T 32 1E,1T 32 32 32 32 1T 32 32 32 32 1T 32 32 1VE 32 1VE 32 1VE 32 5VE 32 1GV,1E 32 1B06,1GV,1T 32 Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Drop 1 A 2.0 PT 11.35 1 Notes C = 120 38.4=11.40(11.35)'.5 F 0.0 PE -0.87 (EL= -2.00 ft) 1 38.4 1.10 T 2.0 0.33926 PF 0.68 12.87 PT 11.16 2 B1 Jct K -factor for drop 1 = 38.4/(11.16)'.5 = 11.49 at Hyd Ref Pts 2 3 4 7 11 Arm -over 1 C = 120 A 2.5 PT 11.16 2 DR1 38.4=11.49(11.16)".5 F 9.0 PE 0.00 2 38.4 1.10 1E 1T T 11.5 0.33917 PF 3.89 12.87 PT 15.06 9 B1 Jct K -factor for arm -over 1 = 38.4/(15.06)".5 = 9.90 at Hyd Ref Pts 9 10 Arm -over 2 C = 120 A 3.0 PT 11.16 3 DR1 38.4=11.49(11.16)'.5 F 9.0 PE 0.00 3 38.4 1.10 1E 1T T 12.0 0.33917 PF 4.06 12.87 PT 15.23 5 B1 Jct K -factor for arm -over 2 = 38.4/(15.23)"'.5 = 9.84 at Hyd Ref Pts 5 6 9 10 Arm -over 3 C = 120 A 2.0 PT 11.16 4 DR1 38.4=11.49(11.16)'.5 F 9.0 PE 0.00 4 38.4 1.10 1E 1T T 11.0 0.33917 PF 3.72 12.87 PT 14.89 8 B1 Jct K -factor for arm -over 3 = 38.4/(14.89)'.5 = 9.95 at Hyd Ref Pts 8 12 vva a aava• a. J • J. V dill Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations 1.714CCL OI UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 1 (Beginning pressure increased due to Hyd Ref Pt 6) C = 120 A 16.0 PT 15.33 5 A02 38.5=9.84(15.33)'.5 F 0.0 PE 0.00 5 38.5 2.15 T 16.0 0.01317 PF 0.21 3.39 A 16.0 PT 15.54 6 A02 38.4=9.84(15.23)'.5 F 0.0 PE 0.00 6 76.9 2.15 T 16.0 0.04732 PF 0.76 6.77 PV= 0.31 A 16.0 PT 16.30 7 DR1 45.3=11.49(15.52)'.5 F 0.0 PE 0.00 7 122.2 2.15 T 16.0 0.11140 PF 1.78 10.76 PV= 0.78 A 7.0 PT 18.08 8 A03 40.7=9.95(16.70)".5 F 12.2 PE 0.00 8 162.9 2.15 1T T 19.2 0.18954 PF 3.64 14.34 PV= 1.38 PT 21.72 13 Cross main Jct K -factor for branchline no. 1 = 162.9/(21.72)'.5 = 34.95 Branchline No. 2 (Beginning pressure increased due to Hyd Ref Pt 10) C = 120 K=19.74=9.90+9.84 A 16.0 PT 15.71 9 A01 + A02 78.2=19.74(15.71)'.5 F 0.0 PE 0.00 9 78.2 2.15 T 16.0 0.04881 PF 0.78 6.89 K=19.74=9.90+9.84 A 16.0 PT 16.49 10 AO1 + A02 77.0=19.74(15.24)".5 F 0.0 PE 0.00 10 155.3 2.15 T 16.0 0.17349 PF 2.78 13.67 PV= 1.26 A 16.0 PT 19.27 11 DR1 47.6=11.49(17.12)'.5 F 0.0 PE 0.00 11 202.8 2.15 T 16.0 0.28442 PF 4.55 17.86 PV= 2.15 A 7.0 PT 23.82 12 A03 45.2=9.95(20.61)".5 F 12.2 PE 0.00 12 248.0 2.15 1T T 19.2 0.41262 PF 7.93 21.84 PV= 3.21 PT 31.75 14 Cross main Jct K -factor for branchline no. 2 = 248.0/(31.75)'.5 = 44.01 Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Cross main 1 (Beginning pressure increased due to Hyd Ref Pt 14) C = 120 A 16.0 PT 33.02 13 BL1 200.9=34.95(33.02)'.5 F 0.0 PE 0.00 13 200.9 3.35 T 16.0 0.03241 PF 0.52 7.30 A 29.0 PT 33.54 14 BL2 254.9=44.01(33.54)".5 F 7.7 PE 0.00 14 455.8 3.35 1VE T 36.7 0.14759 PF 5.42 16.57 PV= 1.79 A 37.0 PT 38.96 15 F 7.7 PE 0.00 15 455.8 3.35 1VE T 44.7 0.14759 PF 6.60 16.57 PT 45.56 16 Top of Riser K -factor for Cross main 1 = 455.8/(45.56)".5 = 67.53 Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Riser 16 455.8 3.35 Notes C = 120 A 11.5 PT 45.56 16 Top of Riser F 7.7 PE 4.98 (EL= 11.50 ft) 1VE T 19.2 0.14762 PF 2.83 16.57 PT 53.37 17 B.O.R. Bulk C = 120 ___= A 217.0 PT 53.37 17 455.8=62.39(53.37)'.5 F 38.5 PE 0.00 17 455.8 3.35 5VE T 255.5 0.14762 PF 37.71 16.57 PT 91.08 18 Top of Riser Riser C = 120 A 11.5 PT 91.09 18 Top of Riser F 17.5 PE 4.98 (EL= 11.50 ft) 18 455.8 4.35 1GV lE T 29.0 0.04140 PF 1.20 9.83 PT 97.27 19 B.O.R. Under ground C = 140 A 70.0 PT 97.27 19 B.O.R. 100.0 gpm = Hose F 58.4 PE 0.00 19 555.8 8.27 1B06 1GV T 128.4 0.00197 PF 4.09 3.32 1B06 = 3.84# 1T A 0.0 PT 101.36 20 100.0 gpm = Hose F 0.0 PE 0.00 20 655.8 8.27 T 0.0 0.00000 PF 0.00 3.92 PT 101.36 21 Supply Jct Available flow at 101.36 psi is 1735.7 gpm which is 1079.9 gpm from curve. Supply pressure available with 655.8 gpm flowing is 146.14 psi, thus system requirement is 44.78 psi below supply curve. (30.6%) UOFPHON2 07/15/99 3:10am Sneez Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Node Detail Discharge Pressure Outlet (psi) K -Value Source Node (gpm) Elevation (ft) Comments 1 38.4 2 38.4 3 38.4 4 38.4 5 38.5 6 38.4 7 45.3 8 40.7 9 78.2 10 77.0 11 47.6 12 45.2 13 14 15 16 17 18 19 100.0 20 100.0 21 11.35 Orif=11.40 11.16 K=11.49 11.16 K=11.49 11.16 K=11.49 15.33 K= 9.84 15.54 K= 9.84 16.30 K=11.49 18.08 K= 9.95 15.71 K=19.74 16.49 K=19.74 19.27 K=11.49 23.82 K= 9.95 33.02 33.54 38.96 45.56 53.37 91.09 97.27 Hose 101.36 Hose 101.36 DR1 DR1 DR1 AO2 AO2 DR1 AO3 AO1 AO1 DR1 AO3 RI2 Pv=0.31 Pv=0.78 Pv=1.38 + AO2 + AO2 Pv=1.26 Pv=2.15 Pv=3.21 Supply 21.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 23.00 11.50 11.50 0.00 0.00 0.00 UOFPHON2 07/15/99 3:10am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 SECOND FLOOR 7100 FORT DENT WAY TUKWILA, WA. Pipe Detail Actual Total Elev Fric Fric Press Press Pipe Diam Len Len Head Flow Loss Loss Vel Nodes @ Beg @ End No. (inch) (Ft) (Ft) (Ft) (Gpm)(Psi/Ft)(Psi)(Fps) Beg End (Psi) (Psi) 1 1.10 2.0 2.0 -2.00 38.4 0.3393 0.68 12.9 1 2 11.35 11.16 2 1.10 2.5 11.5 0.00 38.4 0.3392 3.89 12.9 2 9 11.16 15.71 Fit= 9.0 1E 1T 3 1.10 3.0 12.0 0.00 38.4 0.3392 4.06 12.9 3 5 11.16 15.33 Fit= 9.0 lE 1T 4 1.10 2.0 11.0 0.00 38.4 0.3392 3.72 12.9 4 8 11.16 18.08 Fit= 9.0 lE 1T 5 2.15 16.0 16.0 0.00 38.5 0.0132 0.21 3.4 5 6 15.33 15.54 6 2.15 16.0 16.0 0.00 76.9 0.0473 0.76 6.8 6 7 15.54 16.30 7 2.15 16.0 16.0 0.00 122.2 0.1114 1.78 10.8 7 8 16.30 18.08 8 2.15 7.0 19.2 0.00 162.9 0.1895 3.64 14.3 8 13 18.08 33.02 Fit= 12.2 1T 9 2.15 16.0 16.0 0.00 78.2 0.0488 0.78 6.9 9 10 15.71 16.49 10 2.15 16.0 16.0 0.00 155.3 0.1735 2.78 13.7 10 11 16.49 19.27 11 2.15 16.0 16.0 0.00 202.8 0.2844 4.55 17.9 11 12 19.27 23.82 12 2.15 7.0 19.2 0.00 248.0 0.4126 7.93 21.8 12 14 23.82 33.54 Fit= 12.2 1T 13 3.35 16.0 16.0 0.00 200.9 0.0324 0.52 7.3 13 14 33.02 33.54 14 3.35 29.0 36.7 0.00 455.8 0.1476 5.42 16.6 14 15 33.54 38.96 Fit= 7.7 1VE 15 3.35 37.0 44.7 0.00 455.8 0.1476 6.60 16.6 15 16 38.96 45.56 Fit= 7.7 1VE 16 3.35 11.5 19.2 11.50 455.8 0.1476 2.83 16.6 16 17 45.56 53.37 Fit= 7.7 1VE 17 3.35 217.0 255.5 0.00 455.8 0.1476 37.71 16.6 17 18 53.37 91.09 Fit= 38.5 5VE 18 4.35 11.5 29.0 11.50 455.8 0.0414 1.20 9.8 18 19 91.09 97.27 Fit= 17.5 1GV 1E 19 8.27 70.0 128.4 0.00 555.8 0.0020 0.25 3.3 19 20 97.27 101.36 Fit= 58.4 1B06 1GV 1T 20 8.27 0.0 0.0 0.00 655.8 0.0027 0.00 3.9 20 21 101.36 101.36 STATEWIDE SECURITY FIRE ALARM EQUIPMENT SUBMITTAL FOR FIRE DETECTION SYSTEM FORT DENT III University of Phoenix Tenant Improvement Phase II TUKWILA, WASHINGTON July 14, 1999 A) D9412 Radionics 9412 Control/Communicator B) D8109 Radionics Auxiliary Fire Enclosure, Red C) D928 Radionics Dual Phone Line Switcher D) D122L Radionics Dual Battery Harness E) D192C Radionics Indicating Circuit Supervision Module F) D8132 Radionics Battery Charger Module G) D8004 Radionics Transformer Enclosure H) D1256 Radionics Fire Command Center I) D8125 Radionics Popex Module, Point Bus J) D411 Radionics Synchronization Module, 2 wire K) D443 Radionics 24V, Bell, 10" Shell L) D559S Radionics 24V, Synchronized Mini Horn Strobe, 15/75 cd M) D572S Radionics 24V, Horn Strobe, 110 cd N) D548S Radionics 24V, Strobe, 110 CD 0) WH114911 Wheelock 24V, Exterior Strobe P) SK5395 Silent Knight Super. Bell Circuit Pwr. Supply Prepared By: Statewide Security P.O. Box 2019 Redmond, WA 98052 Phone: 425-558-4640 Fax: 425-558-1290 P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 STATEWIDE SECURITY FIRE ALARM CALCULATIONS BATTERY BACK-UP TIME FORT DENT III University of Phoenix Phase II Tenant Improvement TUKWILA, WA July 14, 1999 FIRE PANEL: Silent Knight, SK5395 Supervised Bell Circuit Power Supply SK5395 75 MA (average current) x 24 Hours = 1.8 AMPS Subtotal 1.8 AMPS Horn/Strobes 1 @ .283 AMPS (average current) = .283 AMPS Strobes 2 @ .163 AMPS (average current) = 3.42 AMPS Subtotal = 3.70 AMPS Divided x 12 (5 min. ring) _ .31 AMPS Total Load 2.11 AMPS System has two (2) 12V, 7 A.H. Batteries in series for 7.0 A.H. Available @ 24 Volts. P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 L 1 STATEWIDE SECURITY 1 Fort Dent I11 University of Phoenix Phase II Tenant Improvement Voltage Loss Calculations July 14, 1999 All conductors are 14 Ga. Solid copper core (12.9 constant), plenum rated, circular mil. Spec. of .4110 Horn/Stobe circuit #1: Not Used Horn/Strobe circuit #2; 6 Devices @ .163 Amperes ea. = .978 Amperes x 2(105'), x 12.9 divided by 4110 = .64 Volts of loss Horn/Strobe circuit #3: 1 Devices @ .177 Amperes ea. and 6 Devices @ .163 = 1.15 Amperes x 2(112') x 12.9, divided by 4110 = .81 Volts of loss. Horn/Strobe circuit #4: 9 Devices @ .163 Amperes ea. = 1.47 Amperes x 2(137'), x 12.9 divided by 4110 = 1.26 Volts of loss. P.O. Box 2019, Redmond, WA 98052 • PH# (425) 558-4640 • PH# (800) 215-6555 • FAX# (425) 558-1290 STATE CONTRACTORS #: WA STATES*044QF CA 552395 OR 0117376 ID 18852 AK 24605 .31&,-‘il 1 S71711111% 2700 Richards Road, Suite 202 Bellevue, WA 98005 June 1, 2008 FORT DENT OFFICE BUILDNG III - UNIVERSITY OF PHOENIX Equipment Bill of Materials QUANTITY MANUFACTURER MODEL NO. DESCRIPTION 1 BOSCH D9412 FIRE ALARM CONTROL PANEL 3 SILENT KNIGHT 5395 3 AMP POWER SUPPLY 22 WHEELOCK MT-24MCW-FR HORN/STROBE 3 WHEELOCK RSS-24MCW-FR STROBE 4 BOSCH FMM-100SATK PULL STATION 2 BOSCH D263 SMOKE DETECTOR 1 BOSCH D1256 ANNUNCIATOR Scope of Work 1. This installation is a relocation of all existing devices. All devices used in this installation are existing and are being relocated to meet new code requirements and to satisfy coverage for the tenant improvement. 2. Reuse existing fire alarm control panel located in the electrical room. 3. Reuse existing Power Supplies located next to the FACP and in the storage room. 4. Relocate all notification devices to meet coverage requirements. 5. Relocate all SLC device to meet coverage requirements. 6. Connect all relocated existing devices to Fire Alarm Control Panel and Notification Control Panel. Honeywell Security Monitoring Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building FACP Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Bosch 09412 Fire Alarm System 1 150 300 150 300 Bosch D1256 Annunciator 1 104 206 104 206 2.2 2.2 508.44 Total System Standby NH 0 0 0 0 0.04 Min. A/H Battery 2 0 0 0 1.86 Required NH Battery 0 0 Total System Current 0 0 254 506 Smoke Detectors / Auxiliary Devices Bosch D263 Smoke Detector 2 0.08 0.12 0.16 0.24 Bosch FMM-100SATK Pull Station 4 0.55 0.55 2.2 2.2 508.44 Total System Standby NH N/A 6.15 0 0 0.04 Min. A/H Battery N/A 6.20 0 0 1.86 Required NH Battery N/A ' 8.05 0 0 0 0 0 0 0 0 N/A 0 0 Device Totals 6 2.36 2.44 Notification Appliances (list all) Standby Hrs. Required N/A 24 N/A 0 5 Total System Standby mA N/A 256.36 N/A 0 508.44 Total System Standby NH N/A 6.15 N/A 0 0.04 Min. A/H Battery N/A 6.20 N/A 0 1.86 Required NH Battery N/A ' 8.05 N/A 0 N/A N/A 0 0 N/A N/A 0 Notification Appliance Totals 0 N/A 0 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 256.36 Total System Alarm mA 508.44 Total System Standby NH 6.15 Total System Alarm AIH 0.04 Min. A/H Battery 6.20 ADD 30% FOR BATTERY DEPLETION 1.86 Required NH Battery ' 8.05 AIH BATTERY PROVIDED FOR SYSTEM I 12 ' Honeywell Security Monitoring Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #1 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Silent Knight 5395 NAC Panel 1 75 175 75 175 0 0 MT-24MCW-FR Hom/Strobe 30cd 4 0 0 0 0 MT-24MCW-FR Hom/Strobe 75cd 7 0 0 0 0 MT-24MCW-FR Hom/Strobe 110cd 1 0 0 0 0 RSS-24MCW-FR Strobe 15cd 1 0 0 Total System Current 0 RSS-24MCW-FR Strobe 30cd 0 75 175 Smoke Detectors / Auxiliary Devices MT-24MCW-FR Hom/Strobe 15cd N/A 41 0 0 MT-24MCW-FR Hom/Strobe 30cd 4 N/A 63 0 0 MT-24MCW-FR Hom/Strobe 75cd 7 N/A 109 0 0 MT-24MCW-FR Hom/Strobe 110cd 1 N/A 140 0 0 RSS-24MCW-FR Strobe 15cd 1 N/A 60 0 0 RSS-24MCW-FR Strobe 30cd 0 0 0 0 0 I 6.00 0 N/A 0 0 Device Totals 0 N/A 0 0 Notification Appliances (list all) MT-24MCW-FR Hom/Strobe 15cd N/A 41 N/A 0 MT-24MCW-FR Hom/Strobe 30cd 4 N/A 63 N/A 252 MT-24MCW-FR Hom/Strobe 75cd 7 N/A 109 N/A 763 MT-24MCW-FR Hom/Strobe 110cd 1 N/A 140 N/A 140 RSS-24MCW-FR Strobe 15cd 1 N/A 60 N/A 60 RSS-24MCW-FR Strobe 30cd N/A 92 N/A 0 I 6.00 I N/A N/A 0 N/A N/A 0 N/A N/A 0 Notification Appliance Totals 13 N/A 1215 Summary Section Standby Hrs. Required 60 Alarm Sounding Minutes 5 Total System Standby mA 75 Total System Alarm mA 1390 Total System Standby AIH 4.50 Total System Alarm A/H 0.12 Min. A/H Battery 4.62 ADD 30% FOR BATTERY DEPLETION 1.38 Required NH Battery I 6.00 I A/H BATTERY PROVIDED FOR SYSTEM 7 Honeywell Security Monitoring Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #2 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Silent Knight 5395 NAC Panel 1 75 175 75 175 0 0 MT-24MCW-FR Horn/Strobe 30cd 2 0 0 0 0 MT-24MCW-FR Horn/Strobe 75cd 4 0 0 0 0 MT-24MCW-FR Horn/Strobe 110cd Min. A/H Battery 0 0 0 0 RSS-24MCW-FR Strobe 15cd Required A/H Battery 0 0 Total System Current 0 RSS-24MCW-FR Strobe 30cd 0 75 175 Smoke Detectors / Auxiliary Devices MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 0 0 MT-24MCW-FR Horn/Strobe 30cd 2 N/A 63 0 0 MT-24MCW-FR Horn/Strobe 75cd 4 N/A 109 0 0 MT-24MCW-FR Horn/Strobe 110cd Min. A/H Battery N/A 140 0 0 RSS-24MCW-FR Strobe 15cd Required A/H Battery N/A 60 0 0 RSS-24MCW-FR Strobe 30cd 0 0 0 0 0 0 N/A 0 0 Device Totals 0 N/A 0 0 Notification Appliances (list all) MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 N/A 0 MT-24MCW-FR Horn/Strobe 30cd 2 N/A 63 N/A 126 MT-24MCW-FR Horn/Strobe 75cd 4 N/A 109 N/A 436 MT-24MCW-FR Horn/Strobe 110cd Min. A/H Battery N/A 140 N/A 0 RSS-24MCW-FR Strobe 15cd Required A/H Battery N/A 60 N/A 0 RSS-24MCW-FR Strobe 30cd N/A 92 N/A 0 N/A N/A 0 N/A N/A 0 N/A N/A 0 Notification Appliance Totals 6 N/A 562 Summary Section Standby Hrs. Required 60 Alarm Sounding Minutes 5 Total System Standby mA 75 Total System Alarm mA 737 Total System Standby AIH 4.50 Total System Alarm A/H 0.06 Min. A/H Battery 4.56 ADD 30% FOR BATTERY DEPLETION 1.37 Required A/H Battery 1 5.93 , A/H BATTERY PROVIDED FOR SYSTEM 7 Honeywell Security Monitoring Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #3 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Silent Knight 5395 NAC Panel 1 75 175 75 175 0 0 MT-24MCW-FR Hom/Strobe 30cd 1 0 0 0 0 MT-24MCW-FR Hom/Strobe 75cd 1 0 0 0 0 MT-24MCW-FR HomlStrobe 110cd 2 0 0 0 0 RSS-24MCW-FR Strobe 15cd 2 0 0 Total System Current 0 RSS-24MCW-FR Strobe 30cd 0 75 175 Smoke Detectors / Auxiliary Devices MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 0 0 MT-24MCW-FR Hom/Strobe 30cd 1 N/A 63 0 0 MT-24MCW-FR Hom/Strobe 75cd 1 N/A 109 0 0 MT-24MCW-FR HomlStrobe 110cd 2 N/A 140 0 0 RSS-24MCW-FR Strobe 15cd 2 N/A 60 0 0 RSS-24MCW-FR Strobe 30cd 0 0 0 0 0 0 N/A 0 0 Device Totals 0 N/A 0 0 Notification Appliances (list all) MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 N/A 0 MT-24MCW-FR Hom/Strobe 30cd 1 N/A 63 N/A 63 MT-24MCW-FR Hom/Strobe 75cd 1 N/A 109 N/A 109 MT-24MCW-FR HomlStrobe 110cd 2 N/A 140 N/A 280 RSS-24MCW-FR Strobe 15cd 2 N/A 60 N/A 120 RSS-24MCW-FR Strobe 30cd N/A 92 N/A 0 N/A N/A 0 N/A N/A 0 N/A N/A 0 Notification Appliance Totals 6 N/A 572 Summary Section Standby Hrs. Required 60 Alarm Sounding Minutes 5 Total System Standby mA 75 Total System Alarm mA 747 Total System Standby A/H 4.50 Total System Alarm A/H 0.06 Min. A/H Battery 4.56 ADD 30% FOR BATTERY DEPLETION 1.37 Required A/H Battery 1 5.93 A/H BATTERY PROVIDED FOR SYSTEM 7 FORT DENT OFFICE BUILDING 11I - UNIVERSITY OF PHOENIX O w 0r. ci X O C C Of Of ■ ■ O o0 m 0 wvi w co w N c1') C X CI 8 O C C Of O Y) — • v) C c • c o 0 N 0Ic4 a Of N O N O X 41, vi 8 C C Oa N N m c0 C ■ N G X c+) C C as N r e ■ c • c c c o � N N cE Na 4. 7 CO O N O CO c V 0 O cp 0 0 0 0 0 1 0 Total Current 0.544 Current 1 j# of Devices I I Current I CO 0 O Na 3 0 G 0 0 0 0 1 0 Total Current 0.671 Current 1 1 # of Devices ' 1 Current I ccc+p) 0 O 0 co N c `) 0 0 c 0 0 0 0 N 0 ND G Current 1 1 # of Devices ' ' Current I CO 01 O CO 0 0 C 0 0 0 0 1 0 1 Total Current 0.562 NNIIINUNIUO E S F N N N N II N N N Current 1 1 # of Devices 1 p N N■ p■■ M N O " N N N N N N c- X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X o8e°°0 D o G d D D 000000 o D o - D O 000000 o o O D O 0o600$ 0 O O , D O xm a j MT-24MCW-FR HomlStrobe 15cd MT-24MCW-FR HomlStrobe 30cd MT-24MCW-FR Horn/Strobe 750 M7-24MCW-FR Nom/Strobe 110cd cc cc 4 4K NN 6 O: NACP #1 Device MT-24MCW-FR HomlStrobe 75cd 51T-24MCW-FR HomlStrobe 30cd MT-24MCW-FR HomlStrobe 75cd MT-24MCW-FR HomlStrobe 110cd RSS-24MCW-FR Strobe 75cd RSS-24MCW-FR Strobe 30cd 8 V > MT-24MCW-FR Hom/Strobe 75cd MT-24MCW-FR Nom/Strobe 30cd MT-24MCW-FR Horn/Strobe 75cd MT-24MCW-FR HomlStrobe 110cd RSS-24MCW-FR Strobe 75cd RSS-24MCW-FR Strobe 30cd NACP #3 Device u x i LL 4 MT-241ACW-FR Hom!Strobe 75cd MT-24MCW-FR Horn/Strobe 110cd RSS-24MCW-FR Strobe 75cd RSS-24MCW-FR Strobe 30cd aU Panel Circuit Panel Circuit O•u FIRE ALARM CALCULATIONS BATTERY BACK-UP TIME FORT DENT III TUKWILA, WA FIRE PANEL: Radionics D9412 Control Communicator Radionics D928 Dual Phone Line Switcher Radionics D192 Indicating Circuit Supervision Module Radionics D1256 Keypad Radionics D9127U ASIC Popit Module's 11 @ 3 MA Radionics D125B Powered Loop Interface Module 250 MA 18 MA 25 MA 108 MA 33 MA 35 MA .469 MA X 24 Hours =11.3 AMP Hour Draw System has two 7.0 A.H. Batterie , = 14.0 AMP Hours Available Silent Knight, SK5395 Supervised Bell Circuit Power Supply SK5395 Horn/Strobes Strobes Bell 75 MA (average current) x 24 Hours Subtotal 14 @ .283 AMPS (average current) 5 @ .135 AMPS (average current) 1 @ .056 AMPS (average current) Subtotal Divided x 12 Subtotal Total = 1.8 AMPS 1.8 AMPS • 3.96 AMPS _ .675 AMPS .056 AMPS • 4.691 AMPS .390 AMPS .390 AMPS (5 minute) = 2.19 AMPS System has two (2) 12V, 7 A.H. Batteries in series for 7.0 A.I1. Available @ 24 Volts. Archer Coristructzcork Imc _ 0 7855 South 206th St Kent, WA 98032 Date 06/23/99 Job: UOFPHONX PROJECT INFORMATION Job_ UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. J Occupancy Ordinary Hazard Group I Density 0.15 gpm/sq.ft. Area of Operation 1500 square feet Area per Sprinkler 16X16 SPACING Authority having Jurisdiction_ _ NFPA-13 Hose 100.0 gpm Inside Hose, 100.0 gpm Outside Hose System type_ _ Wet Water Supply _ 155.00 psi Static, 105.00 psi Residual @ 1671.0 gpm Sprinklers _ _ Large Orifice CALCULATION SUMMARY Demand 113.42 psi @ 568.4 gpm @ B.O.R. 117.69 psi @ 768.4 gpm @ Supply 143.12 psi available @ 768.4 gpm Demand is below curve by 25.43 psi Notes: __oria+. I>K. +a G oCetinCite #F>. os IL 11 COO`i> Sheet of Archer Construction Inc. Description of Fitting abbreviations Code Description T Tee E Ninety degree elbow VT Victaulic tee VE Victaulic ninety degree elbow B06 Backflow: Febco Backflow Model 805Y Dbl. Check Valve Assy. GV Gate valve Description of Other abbreviations Code Description AO Arm -over DR Drop BL Branch Line RN Riser Nipple CM Cross Main PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction PV Velocity Pressure -.5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length UOFPHONX 06/23/99 0:52am Sheet No. Code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 DR1 DR2 AO1 BL1 BL1 BL1 BL1 BL1 BL2 BL2 BL3 BL3 BL3 BL3 BL3 RN1 RN2 RN3 CM1 CM1 CM1 BU1 RI1 UG1 UG1 Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Raw data previous to any calculations Diam Length Kfacl 1.104 2.0 11.4 1.104 2.0 11.4 1.104 2.0 DR2 1.687 13.0 DR1 1.687 3.0 DR1 1.687 16.0 AO1 1.687 14.0 AO1 1.687 7.0 DR1 1.687 11.0 DR1 1.687 16.5 DR1 1.687 16.0 DR1 1.687 8.0 DRI 1.687 8.0 DR1 1.687 14.0 AO1 1.687 7.0 DR1 1.687 1.0 BL1 1.687 1.0 BL2 1.687 1.0 BL3 3.352 8.0 RN1 3.352 8.0 RN2 3.352 148.0 RN3 3.352 13.0 CM1 4.352 11.0 BU1 8.270 70.0 RI1 8.270 0.0 Kfac2 Press Elev 11.40 -2.00 11.40 -2.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 11.00 0.00 0.00 0.00 0.00 of Hose HW Vel Fittings 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 100.0 100.0 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 140 140 32 1T 32 lE 32 1T 32 32 32 32 32 1T 32 32 1T 32 32 32 32 32 1T 32 1T 32 1T 32 1T 32 32 32 1VT 32 2VE 32 1GV,1E 32 1B06,1GV,1T 32 UOFPHONX 06/23/99 0:52am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Drop 1 C = 120 A 2.0 PT 11.40 1 38.5=11.40(11.40)'.5 F 6.4 PE -0.87 (EL= -2.00 ft) 1 38.5 1.10 1T T 8.4 0.34065 PF 2.86 12.90 PT 13.40 4 B1 Jct K -factor for drop 1 = 38.5/(13.40)".5 = 10.52 at Hyd Ref Pts 4 5 8 9 10 11 12 13 15 Drop 2 C = 120 A 2.0 PT 11.40 2 38.5=11.40(11.40)'.5 F 2.6 PE -0.87 (EL= -2.00 ft) 2 38.5 1.10 lE T 4.6 0.34065 PF 1.56 12.90 PT 12.09 3 B1 Jct K -factor for drop 2 = 38.5/(12.09)'.5 = 11.07 Arm -over 1 C = 120 A 2.0 PT 12.09 3 DR2 38.5=11.07(12.09)-.5 F 6.4 PE 0.00 3 38.5 1.10 1T T 8.4 0.34080 PF 2.87 12.90 PT 14.96 6 B1 Jct K -factor for arm -over 1 = 38.5/(14.96)"'.5 = 9.95 at Hyd Ref Pts 6 7 14 UOFPHONX 06/23/99 0:52am Sheet Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting No (gpm) (inch) and Dev Branchline No. 1 (Beginning Length Fr Loss Press Hyd Vel (ft) (psi/ft) (psi) Ref (fps) pressure increased due A 13.0 PT 0.0 PE 13.0 0.05040 PF 3.0 PT 0.0 PE 3.0 0.18008 PF 16.0 PT 0.0 PE 16.0 0.36379 PF 14.0 PT 0.0 PE 14.0 0.63977 PF 7.0 PT 10.0 PE 17.0 1.06864 PF PT 41.8=10.52(15.82)'.5 F 4 41.8 1.69 T A 41.4=10.52(15.51)'.5 F 5 83.3 1.69 T A 38.5=9.95(14.96)'.5 F 6 121.8 1.69 T A 43.5=9.95(19.05)'.5 F 7 165.2 1.69 T A 52.8=10.52(25.20)'.5 F 8 218.0 1.69 1T T K -factor for branchline no. 1 = to Hyd Ref Pt 6) 15.82 4 0.00 0.66 6.00 16.48 5 0.00 0.54 11.95 17.02 6 0.00 5.82 17.48 22.84 7 0.00 8.96 23.72 31.79 8 0.00 18.21 31.29 50.00 16 Riser 218.0/(50.00)'.5 = 30.83 Riser Nipple (Top of RN =Branchline 1) A 1.0 PT 218.0=30.83(50.01)'.5 F 10.0 PE 16 218.0 1.69 1T T 11.0 1.06846 PF PT 50.01 0.43 11.80 62.23 K -factor for riser nipple = 218.0/(62.23)'.5 = 27.63 Branchline No. 2 (Beginning 39.0=10.52(13.75)".5 9 39.0 1.69 38.5=10.52(13.41)".5 10 77.5 1.69 1T pressure A F T A F T increased due 11.0 PT 0.0 PE 11.0 0.04428 PF 16.5 PT 10.0 PE 26.5 0.15777 PF PT K -factor for branchline no. 2 = Riser Nipple (Top of RN =Branchline 2) A 77.5=18.05(18.43)".5 F 17 77.5 1.69 1T T of Notes C = 120 DR1 DR1 PV= 0.96 AO1 PV= 2.06 AO1 PV= 3.78 DR1 PV= 6.59 Nipple Jct C = 120 BL1 ft) 16 (EL= 1.00 31.29 19 Cross main Jct to Hyd Ref Pt 10) 13.75 9 0.00 0.49 5.60 14.24 10 0.00 4.19 11.13 18.43 17 Riser 77.5/(18.43)'.5 = 18.05 1.0 PT 10.0 PE 11.0 0.15769 PF PT 18.43 0.43 1.74 20.60 K -factor for riser nipple =77.5/(20.60)'.5 = 17.07 C = 120 DR1 DR1 PV= 0.83 Nipple Jct C = 120 17 BL2 (EL= 1.00 ft) 11.12 20 Cross main Jct UOFPHONX 06/23/99 0:52am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of s UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 3 (Beginning pressure increased due to Hyd Ref Pt 14) C = 120 A 16.0 PT 13.65 11 DR1 38.9=10.52(13.65)'.5 F 0.0 PE 0.00 11 38.9 1.69 T 16.0 0.04397 PF 0.70 5.58 A 8.0 PT 14.35 12 DR1 38.7=10.52(13.52)'.5 F 0.0 PE 0.00 12 77.5 1.69 T 8.0 0.15781 PF 1.26 11.13 PV= 0.83 A 8.0 PT 15.61 13 DR1 39.0=10.52(13.73)'.5 F 0.0 PE 0.00 13 116.5 1.69 T 8.0 0.33525 PF 2.68 16.72 PV= 1.88 A 14.0 PT 18.30 14 AO1 38.5=9.95(14.97)'.5 F 0.0 PE 0.00 14 155.0 1.69 T 14.0 0.56860 PF 7.96 22.25 PV= 3.33 A 7.0 PT 26.26 15 DR1 47.7=10.52(20.56)".5 F 10.0 PE 0.00 15 202.7 1.69 1T T 17.0 0.93393 PF 15.91 29.10 PV= 5.70 Nipple Jct PT 42.17 18 Rise K -factor for branchline no. 3 = 202.7/(42.17)".5 = 31.21 Riser Nipple (Top of RN =Branchline 3) C = 120 A 1.0 PT 42.17 18 BL3 202.7=31.21(42.17)'.5 F 10.0 PE 0.43 (EL= 1.00 ft) 18 202.7 1.69 1T T 11.0 0.93387 PF 10.31 29.09 PT 52.91 21 Cross main Jct K -factor for riser nipple = 202.7/(52.91)'.5 = 27.87 UOFPHONX 06/23/99 0:52am Pipe Flow No (gpm) Cross main 1 Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Dia Fitting (inch) and Dev 218.0=27.63(62.23)".5 19 218.0 3.35 133.8=17.07(61.43)'.5 20 351.8 3.35 216.6=27.87(60.39)'.5 21 568.4 3.35 1VT Length Fr Loss Press Hyd Vel (ft) (psi/ft) (psi) Ref (fps) A 8.0 PT F 0.0 PE T 8.0 0.03772 PF A 8.0 PT F 0.0 PE T 8.0 0.09144 PF A 148.0 PT F 20.0 PE T 168.0 0.22208 PF PT K -factor for Cross main 1 62.23 19 0.00 0.30 62.54 20 0.00 0.73 63.27 21 0.00 37.31 100.58 22 = 568.4/(100.58)'.5 = 56.68 7.93 12.79 20.66 Notes C = 120 RN#16 RN#17 PV= 1.10 RN#18 PV= 2.87 Bulk Jct UOFPHONX 06/23/99 0:52am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Bulk C = 120 ___= A 13.0 PT 100.58 22 CM 1 568.4=56.68(100.58)".5 F 15.4 PE 0.00 22 568.4 3.35 2VE T 28.4 0.22209 PF 6.31 20.67 PT 106.88 23 Top of Riser Riser C = 120 A 11.0 PT 106.88 23 Top of Riser F 17.5 PE 4.76 (EL= 11.00 ft) 23 568.4 4.35 1GV 1E T 28.5 0.06228 PF 1.78 12.26 PT 113.42 24 B.O.R. Under ground C = 140 A 70.0 PT 113.42 24 B.O.R. 100.0 gpm = Hose F 58.4 PE 0.00 24 668.4 8.27 1B06 1GV T 128.4 0.00277 PF 4.27 3.99 1B06 = 3.91* 1T A 0.0 PT 117.69 25 100.0 gpm = Hose F 0.0 PE 0.00 25 768.4 8.27 T 0.0 0.00000 PF 0.00 4.59 PT 117.69 26 Supply Jct Available flow at 117.69 psi is 1426.4 gpm which is 658.0 gpm from curve. Supply pressure available with 768.4 gpm flowing is 143.12 psi, thus system requirement is 25.43 psi below supply curve. (17.8%) UOFPHONX 06/23/99 0:52am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) . 7100 FORT DENT WAY TUKWILA, WA. Node Detail Discharge Pressure Outlet Elevation (ft) Comments Node (gpm) (psi) K -Value Source 1 38.5 2 38.5 3 38.5 4 41.8 5 41.4 6 38.5 7 43.5 8 52.8 9 39.0 10 38.5 11 38.9 12 38.7 13 39.0 14 38.5 15 47.7 16 17 18 19 20 21 22 23 24 100.0 25 100.0 26 11.40 Orif=11.40 11.40 Orif=11.40 12.09 K=11.07 15.82 K=10.52 16.48 K=10.52 17.02 K= 9.95 22.84 K= 9.95 31.79 K=10.52 13.75 K=10.52 14.24 K=10.52 13.65 K=10.52 14.35 K=10.52 15.61 K=10.52 18.30 K= 9.95 26.26 K=10.52 50.01 18.43 42.17 62.23 62.54 63.27 100.58 106.88 113.42 Hose 117.69 Hose 117.69 DR2 DR1 DR1 Pv=0.96 AO1 Pv=2.06 AO1 Pv=3.78 DR1 Pv=6.59 DR1 DR1 Pv=0.83 DR1 DR1 Pv=0.83 DR1 Pv=1.88 AO1 Pv=3.33 DR1 Pv=5.70 RI1 Supply 10.00 10.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 11.00 11.00 11.00 11.00 11.00 0.00 0.00 0.00 UOFPHONX 06/23/99 0:52am Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations Sheet of UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Detail Actual Total Elev Fric Fric Press Press Pipe Diam Len Len Head Flow Loss Loss Vel Nodes @ Beg @ End No. (inch) (Ft) (Ft) (Ft) (Gpm)(Psi/Ft)(Psi)(Fps) Beg End (Psi) (Psi) 1 1.10 2.0 8.4 -2.00 38.5 0.3406 2.86 12.9 1 4 11.40 15.82 Fit= 6.4 1T 2 1.10 2.0 4.6 -2.00 38.5 0.3406 1.56 12.9 2 3 11.40 12.09 Fit= 2.6 lE 3 1.10 2.0 8.4 0.00 38.5 0.3408 2.87 12.9 3 6 12.09 17.02 Fit= 6.4 1T 4 1.69 13.0 13.0 0.00 41.8 0.0504 0.66 6.0 4 5 15.82 16.48 5 1.69 3.0 3.0 0.00 83.3 0.1801 0.54 12.0 5 6 16.48 17.02 6 1.69 16.0 16.0 0.00 121.8 0.3638 5.82 17.5 6 7 17.02 22.84 7 1.69 14.0 14.0 0.00 165.2 0.6398 8.96 23.7 7 8 22.84 31.79 8 1.69 7.0 17.0 0.00 218.0 1.0686 18.21 31.3 8 16 31.79 50.01 Fit= 10.0 1T 9 1.69 11.0 11.0 0.00 39.0 0.0443 0.49 5.6 9 10 13.75 14.24 10 1.69 16.5 26.5 0.00 77.5 0.1578 4.19 11.1 10 17 14.24 18.43 Fit= 10.0 1T 11 1.69 16.0 16.0 0.00 38.9 0.0440 0.70 5.6 11 12 13.65 14.35 12 1.69 8.0 8.0 0.00 77.5 0.1578 1.26 11.1 12 13 14.35 15.61 13 1.69 8.0 8.0 0.00 116.5 0.3352 2.68 16.7 13 14 15.61 18.30 14 1.69 14.0 14.0 0.00 155.0 0.5686 7.96 22.3 14 15 18.30 26.26 15 1.69 7.0 17.0 0.00 202.7 0.9339 15.91 29.1 15 18 26.26 42.17 Fit= 10.0 1T 16 1.69 1.0 11.0 1.00 218.0 1.0685 11.80 31.3 16 19 50.01 62.23 Fit= 10.0 1T 17 1.69 1.0 11.0 1.00 77.5 0.1577 1.74 11.1 17 20 18.43 62.54 Fit= 10.0 1T 18 1.69 1.0 11.0 1.00 202.7 0.9339 10.31 29.1 18 21 42.17 63.27 Fit= 10.0 1T 19 3.35 8.0 8.0 0.00 218.0 0.0377 0.30 7.9 19 20 62.23 62.54 20 3.35 8.0 8.0 0.00 351.8 0.0914 0.73 12.8 20 21 62.54 63.27 21 3.35 148.0 168.0 0.00 568.4 0.2221 37.31 20.7 21 22 63.27 100.58 Fit= 20.0 1VT 22 3.35 13.0 28.4 0.00' 568.4 0.2221 6.31 20.7 22 23 100.58 106.88 Fit= 15.4 2VE 23 4.35 11.0 28.5 11.00 568.4 0.0623 1.78 12.3 23 24 106.88 113.42 Fit= 17.5 1GV 1E 24 8.27 70.0 128.4 0.00 668.4 0.0028 0.36 4.0 24 25 113.42 117.69 Fit= 58.4 1B06 1GV 1T UOFPHONX 06/23/99 0:52am Sheet of Archer Construction Inc. Sprinkler Systems Hydraulic Flow Calculations UNIVERSITY OF PHOENIX (FORT DENT 3 FIRST FLOOR) 7100 FORT DENT WAY TUKWILA, WA. Pipe Detail Actual Total Elev Fric Fric Press Press Pipe Diam Len Len Head Flow Loss Loss Vel Nodes @ Beg @ End No. (inch) (Ft) (Ft) (Ft) (Gpm)(Psi/Ft)(Psi)(Fps) Beg End (Psi) (Psi) 25 8.27 0.0 0.0 0.00 768.4 0.0036 0.00 4.6 25 26 117.69 117.69 ,9 PATRIOT E PROTECTION 2004-A 48th AVENUE CT E. TACOMA, WA 98424 FAX (206) 922-6150 TEL (206) 926-2290 HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME TIS 744 -rt ADDRESS 7 100 R9(2:1" 1 De. ►.)T Way' fl) Ic-u-./ L -P . WA '6 I &,e, CONTRACT NO. t%- 4-61 15 DATE - 2-6)- BY', yrs- LlS1EG k •[ SYSTEM DESIGNATION: HAZARD DESCRIPTION: nr{-t c. -6:=v-t)- i \, .. Pte_ -tom � ,, cvee � [PER NFPA 13 (1991) SECTION A-1.4.7] HAZARD CLASS PER NFPA 13 : ov-P t 1-,AR'f c--9 1 [LIGHT, ORDINARY GP I, ORDINARY GP II, EXTRA, STORAGE] SPECIFIC RULING: ,-r,ew o - ts-1,e.- 1L 54-1.6' e)(7 -0k b-') rift 1,46,1> ('(;-i x L -O - �Gc.r, t 4 w5 RULING MADE BY: IJ OF -T--L4 vul!..c, DENSITY: ,1 GPM OVER THE MOST HYDRAULICALLY REMOTE I Soo SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: INSIDE HOSE GPM OUTSIDE HOSE GPM IN -RACK SPRINKLER DEMAND 1,/,\ GPM SYSTEM TYPE: G -!C ID [TREE, LOOP, GRID] TOTAL NUMBER OF SPRINKLERS ON SYSTEM "C" FACTOR USED: OVERHEAD 12-v UNDERGROUND MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: 16,4 >, (C; SQUARE FEET SPRINKLER MANUFACTURER: PE.t.-tP-43L4_ MODEL: G XL -o Ecoµ ORIFICE SIZE: K -FACTOR: 11. 1.4- TEMP: \6 S ° F WATER SUPPLY: ELEVATION OF TEST: STATIC 15S PSI DATE OF TEST: RESIDUAL I05 PSI DATA PROVIDED BY: DATA- FR+A T��j-r FLOW 1,6P/ GPM LOCATION OF TEST: BASE OF RISER DEMAND 6,73 76. GPM REQUIRED AT X22,53 PSI (INCLUDING GPM FOR HOSE STREAMS) SUMMARY GPM REQUIRED AT 124 .Og AT CONNECTION TO S t.Tf Loop PSI (INCLUDING GPM FOR TOTAL HOSE STREAMS) 'SHEET OF Sd NI 3E1f1SS2Eid TJK-v,llcd4'1S1608 0. (Z— 4(15 II iI ;'ii I1 �I I ' l 1I( 1 I J l i l 1 '1 f I-1 I•' I I I ' 4 .'..1_.I" 1 1 I I 1 I I I, I i T 1. , I 1 �"'__ , 1 i 1 1, i;I j 1i, It; ; ;;;� �] ; ,;;if 1 1' 1 I 1 1 I. i I I 1 1 l I 1 l 4 yI I i I; , 1 1 1 ' 1 I I : 1 II ; � , 1 : It ������1 I :-.._4 ' T • i I I I .. , I .1 I - --i-T- i;i�l I�' ! II I� I`1 II I �Ii ��i jl i it iii 1I ' I ! 1 1 1 I I MO 1 1 I I 1 1 1 � f l ' I 1 I 1 � I 1 �� I .�_ i I 1 I j' � a 0 I -I : 0 3 li 11 I_f it ;Ii ,I WATER SUPPLY DATA 1 STATIC 15 PSI RESIDUAL t°5 - PSI FLOWING 14_67 t 6,rt" r ^ 1 ill II! I __ ] 1l 1 ! i I 1 'iltf'. 1_ tED AT �2 3PM FOR HOSE !III,,• .II III�II! : SUMMAR EOUIRED A St -re. 711 1 ' ®1� +.y - �t' 11 111 ' 1 •r I I t , I I I 1 1t ---- I 1 •I111111.1 it I • •I.-, I ©111111• I i, , -111 iII • N dl ��� I11 �II 1111 I ( O Sd NI 3E1f1SS2Eid SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 1 THERAPUTIC ASSOCIATES T.I. SPR 122 123 124 131 132 133 134 135 143 144 145 146 151 161 162 152 FLOW TEST RESULTS STATIC RESIDUAL AT 1671.0 GPM PRESSURE AVAILABLE AT 673.8 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL FLOW 48.17 47.20 49.20 46.51 43.81 38.90 38.40 39.94 44.12 42.31 41.43 43.07 46.55 41.28 38.96 23.90 MINIMUM FLOW K -FACTOR 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 38.40 11.40 14.87 5.62 TOTAL WATER REQUIRED FOR SYSTEM TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 PRESSURE 17.85 17.15 18.62 16.65 14.77 11.64 11.35 12.28 14.98 13.77 13.20 14.28 16.68 13.11 11.68 18.09 155.00 PSI 105.00 PSI 145.68 PSI 673.76 GPM 673.76 GPM 126.08 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.028 PSI MAXIMUM VELOCITY IN PIPES 24.50 FPS SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 2 THERAPUTIC ASSOCIATES T.I. FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 34 134 Q 38.40 62 162 61 62 Q 38.96 Q 38.96 1.049 L 1.00 0.4350 PT 11.35 (134) F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 2.61 PT 13.53 ( 34) 1.380 L 1.00 0.1175 PT 11.68 (162) F=E F 3.00 PE -0.43 DR C120 T 4.00 PF 0.47 1.380 L 16.00 0.1175 PT 11.72 ( 62) F=0 F 0.00 PE 0.00 BN C120 T 16.00 PF 1.88 PT 13.60 ( 61) 61 161 1.380 L 1.00 0.1308 PT 13.11 (161) Q 41.28 F=T F 6.00 PE -0.43 DR C120 T 7.00 PF 0.92 19 61DQ 38.96 1.610 L 42.75 0.2111 PT 13.60 ( 61) Q 80.24 F=T/2E F 16.00 PE 0.00 BN C120 T 58.75 PF 12.40 15 19 3.352 L 2.00 0.0059 PT 26.00 ( 19) Q 80.24 F=0 F 0.00 PE 0.00 NC C120 T 2.00 PF 0.01 PT 26.01 ( 15) 52 152 1.049 L 1.50 0.1810 PT 18.09 (152) Q 23.90 F=T F 5.00 PE -0.65 DR C120 T 6.50 PF 1.18 51 52 1.049 L 8.00 0.1810 PT 18.62 ( 52) Q 23.90 F=0 F 0.00 PE 0.00 BN C120 T 8.00 PF 1.45 PT 20.07 ( 51) 51 151 1.049 L 1.50 0.6212 PT 16.68 (151) Q 46.55 F=T F 5.00 PE -0.65 DR C120 T 6.50 PF 4.04 17 51DQ 23.90 1.380 L 5.00 0.3516 PT 20.07 ( 51) Q 70.46 F=2T F 12.00 PE 0.22 BN C120 T 17.00 PF 5.98 PT 26.27 ( 17) 46 146 1.049 L 1.00 0.5380 PT 14.28 (146) Q 43.07 F=E F 2.00 PE -0.43 DR C120 T 3.00 PF 1.61 45 46 2.067 L 16.00 0.0198 PT 15.46 ( 46) Q 43.07 F=0 F 0.00 PE 0.00 BN C120 T 16.00 PF 0.32 PT 15.78 ( 45) SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 3 THERAPUTIC ASSOCIATES T.I. FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 45 145 Q 41.43 44 144 Q 42.31 43 143 Q 44.12 35 135 34 35 Q 39.94 Q 39.94 1.049 L 1.00 0.5005 PT 13.20 (145) F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.00 PT 15.77 ( 45) 1.049 L 1.00 0.5204 PT 13.77 (144) F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.12 PT 16.46 ( 44) 1.049 L 1.00 0.5624 PT 14.98 (143) F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.37 PT 17.92 ( 43) 1.049 L 1.00 0.4679 PT 12.28 (135) F=E F 2.00 PE -0.43 DR C120 T 3.00 PF 1.40 2.067 L 16.00 0.0172 PT 13.25 ( 35) F=0 F 0.00 PE 0.00 BN C120 T 16.00 PF 0.28 33 34DQ 38.40 2.067 L 6.00 0.0598 PT 13.53 ( 34) Q 78.34 F=0 F 0.00 PE 0.00 BN C120 T 6.00 PF 0.36 PT 13.89 ( 33) 33 133 Q 38.90 1.049 L 1.00 0.4455 PT 11.64 (133) F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 2.67 32 33DQ 78.34 2.067 L 20.00 0.1261 PT 13.88 ( 33) Q 117.24 F=2E F 10.00 PE 0.00 BN C120 T 30.00 PF 3.78 PT 17.66 ( 32) 32 132 1.049 L 1.00 0.5551 PT 14.77 (132) Q 43.81 F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.33 31 32DQ 117.24 2.067 L 10.00 0.2269 PT 17.67 ( 32) Q 161.05 F=0 F 0.00 PE 0.00 BN C120 T 10.00 PF 2.27 PT 19.94 ( 31) 31 131 1.049 L 1.00 0.6201 PT 16.65 (131) Q 46.51 F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.72 SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 4 THERAPUTIC ASSOCIATES T..I. FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 30 31DQ 161.05 2.067 Q 207.56 L 6.75 0.3628 PT 19.94 ( 31) F=T F 10.00 PE 0.00 BN C120 T 16.75 PF 6.08 PT 26.02 ( 30) 24 124 1.049 L 1.00 0.6880 PT 18.62 (124) Q 49.20 F=E F 2.00 PE -0.43 DR C120 T 3.00 PF 2.06 23 24 2.227 L 16.00 0.0176 PT 20.25 ( 24) Q 49.20 F=0 F 0.00 PE 0.00 BN C120 T 16.00 PF 0.28 PT 20.53 ( 23) 23 123 1.049 L 1.00 0.6373 PT 17.15 (123) Q 47.20 F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.82 22 23DQ 49.20 2.227 L 14.00 0.0611 PT 20.54 ( 23) Q 96.40 F=0 F 0.00 PE 0.00 BN C120 T 14.00 PF 0.86 PT 21.40 ( 22) 22 122 1.049 L 1.00 0.6616 PT 17.85 (122) Q 48.17 F=T F 5.00 PE -0.43 DR C120 T 6.00 PF 3.97 21 22DQ 96.40 2.227 L 16.00 0.1292 PT 21.39 ( 22) Q 144.57 F=0 F 0.00 PE 0.00 BN C120 T 16.00 PF 2.07 15 21 2.227 L 3.75 0.1292 PT 23.46 ( 21) Q 144.57 F=T F 16.00 PE 0.00 BN C120 T 19.75 PF 2.55 PT 26.01 ( 15) 44 45 2.067 L 10.00 0.0688 PT 15.78 ( 45) Q 84.50 F=0 F 0.00 PE 0.00 BN C120 T 10.00 PF 0.69 43 44DQ 42.31 2.067 L 10.00 0.1458 PT 16.47 ( 44) Q 126.81 F=0 F 0.00 PE 0.00 BN C120 T 10.00 PF 1.46 16 43DQ 44.12 2.067 L 22.75 0.2533 PT 17.93 ( 43) Q 170.93 F=T F 10.00 PE 0.00 BN C120 T 32.75 PF 8.30 PT 26.23 ( 16) 2 3 3.352 L 30.00 0.3042 PT 81.80 ( 3) Q 673.76 F=E F 8.00 PE 0.00 NC C120 T 38.00 PF 11.56 PT 93.36 ( 2) SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 5 THERAPUTIC ASSOCIATES T.I. FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 15 30 Q 0.67 3.352 8 15DQ 224.81 2.227 Q 225.48 4 8DQ -89.57 2.227 Q 135.92 3 4 3.352 Q 135.92 5 8 2.227 Q 89.57 16 30 3.352 Q 206.89 17 16DQ -47.38 3.352 Q 159.51 18 17DQ 70.46 3.352 Q 229.97 7 18 2.227 Q 229.97 6 7 3.352 Q 229.97 6 16 Q 218.31 2 227 L 120.00 0.2770 PT 26.22 16) F=T,2E/2E,T F 52.00 PE 0.00 BL C120 T 172.00 PF 47.64 L 16.00 0.1431 PT 73.86 ( 6) F=0 F 0.00 PE 0.00 CM1 C120 T 16.00 PF 2.29 L 10.00 0.0000 PT 26.01 F=0 F 0.00 PE 0.00 CM2 C120 T 10.00 PF 0.00 L 94.00 0.2941 PT 26.01 F=6E/2T F 62.00 PE 0.00 BL C120 T 156.00 PF 45.88 L 60.00 0.1153 PT 71.89 F=T,E F 21.00 PE 0.00 BL C120 T 81.00 PF 9.34 L 10.00 0.0157 PT 81.23 F=T F 26.00 PE 0.00 CM1 C120 T 36.00 PF 0.57 PT 81.80 L 48.00 0.0533 PT 71.89 F=T/T F 32.00 PE 0.00 BL C120 T 80.00 PF 4.26 PT 76.15 30) 15) 8) 4) 3) 8) ( 5) L 6.00 0.0342 PT 26.01 ( 30) F=0 F 0.00 PE 0.00 CM2 C120 T 6.00 PF 0.21 L 2.00 0.0212 PT 26.22 ( 16) F=0 F 0.00 PE 0.00 CM2 C120 T 2.00 PF 0.04 L 14.00 0.0416 PT 26.26 ( 17) F=0 F 0.00 PE 0.00 CM2 C120 T 14.00 PF 0.58 L 120.00 0.3050 PT 26.84 ( 18) F=T/T F 32.00 PE 0.00 BL C120 T 152.00 PF 46.36 L 16.00 0.0416 PT 73.20 ( 7) F=0 F 0.00 PE 0.00 CM1 C120 T 16.00 PF 0.67 PT 73.87 ( 6) ( 5 6DQ 229.97 3.352 Q 448.28 SUBMITTAL SERIAL NO:2454H-09 06-30-1999 PAGE 6 THERAPUTIC ASSOCIATES T.I. FROM TO FLOW DIAM EQUIV P -LOSS PRESSURE GPM IN PIPE PSI/FT SUMMARY LEN/FT PSI 3 5DQ 89.57 3.352 L 2.00 0.2005 PT 76.15 ( 5) Q 537.84 F=T F 26.00 PE 0.00 CM1 C120 T 28.00 PF 5.61 PT 81.76 ( 3) 1 2 3.`352 L 14.00 0.3042 PT 93.33 ( 2) Q 673.76 F=T,E/E F 42.00 PE 4.33 FR C120 T 56.00 PF 17.04 99 1 4.352 L 12.00 0.0853 PT114.70 ( 1) Q 673.76 F=BV,E F 29.00 PE 4.33 FR C120 T 41.00 PF 3.50 0 99 6.160 L 50.00 0.0118 PT122.53 ( 99)'Psc of Q 673.76 F=T,GV/2E F 68.00 PE 2.16 (zi.SeiC- UN C140 T 118.00 PF 1.39 PRESSURE AVAILABLE AT NODE 0 AT 673.8 GPM MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.028 PSI MAXIMUM VELOCITY IN PIPES 24.50 FPS PT126.08 ( 0) 145.7 PSI to*' VyW1� 7v SM TH,.FIRE SYSTEMS, INC. 1106 54th Avenue East • Tacoma, Washington 98424 (253) 926-1880 • FAX (253) 926-2350 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME HYUNDAI T.I. JOB NO. T1-119 DATE 5/11/99 ADDRESS 7100 FORT DENT WAY BY LORIE COLE TUKWILA, WASHINGTON SYSTEM DESIGNATION: 1 HAZARD DESCRIPTION: OFFICES HAZARD CLASS PER NFPA 13 : ORDINARY HAZARD GROUP 1 SPECIFIC RULING: RULING MADE BY: OF DENSITY: .15 GPM OVER THE MOST HYDRAULICALLY REMOTE 1500 SQ. FT. ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: INSIDE HOSE 0 GPM OUTSIDE HOSE 250 GPM CITY WATER MAIN (NODE 0) IN -RACK SPRINKLER DEMAND GPM SYSTEM TYPE: WET TOTAL NUMBER OF SPRINKLERS THIS SYSTEM 29 "C" FACTOR OVERHEAD : 120 "C" FACTOR UNDERGROUND : 140 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: 256 SQUARE FEET SPRINKLER MANUFACTURER: RELIABLE MODEL: G XLO-ECOH TEMPERATURE: 165 ° F K -FACTOR: 11.4 ORIFICE SIZE: .64" WATER SUPPLY: STATIC 155 PSI RESIDUAL 105 PSI FLOW 1671 GPM ELEVATION OF TEST: --- DATE OF TEST: DATA PROVIDED BY: CITY OF TUKWILA PUBLIC WORKS DEPT. LOCATION OF TEST: AT THE SITE BASE OF RISER DEMAND 528.17 GPM REQUIRED AT 48.65 PSI (INCLUDING 0 GPM FOR HOSE STREAMS) SUMMARY 778.17 GPM REQUIRED AT 53.90 PSI AT CONNECTION TO CITY WATER MAIN (INCLUDING 250 GPM FOR TOTAL HOSE STREAMS) Z��4•T4-11=14 0 W Ow o " Z nl VIVA 14.1:1il1WiTALI W 10 W 0 ✓ r F to tt$1 zO 8 i • N 8 ISd NI 31IflSS31Id st O 0 0) co O a O N O SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 FLOW TEST RESULTS Water Supply STATIC 155.00 PSI RESIDUAL 105.00 PSI C 1671.00 GPM CITY PRESSURE AVAILABLE. AT 778.2 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR 351 50.16 38.40 352 48.41 38.40 353 25.40 18.90 354 25.37 14.87 355 26.01 14.87 356 25.20 14.87 357 24.93 14.87 358 24.73 18.11 359 23.46 18.75 360 23.45 14.87 361 49.26 38.40 362 42.10 38.40 363 21.83 14.87 364 38.40 38.40 365 39.87 38.40 366 39.60 38.40 11.40 11.40 5.62 5.62 5.62 5.62 5.62 5.62 5.62 5.62 11.40 11.40 5.62 11.40 11.40 11.40 TOTAL WATER REQUIRED FOR SYSTEM OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 251 TO 351 PRESSURE 1;.36 18.03 20.43 20.37 21.42 20.11 19.68 19.36 17.43 17.41 18.67 13.64 15.08 11.35 12.23 12.07 142.84 PSI 528.17 GPM 250.00 GPM 778.17 GPM 53.88 PSI 0.00 PSI 18.62 FPS 05-11-1999 PAGE 1 SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 2 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 264 364 1.049 L 2.75 C=120 PT 11.35 (364) O 38.40 F=T,E F 7.00 PE -0.32 DR T 9.75 0.4350 PF 4.24 PT 15.27 (264) 266 366 265 266 O 39.60 Q 39.60 1.049 L 0.75 C=120 PT 12.07 (366) F=T F 5.00 PE -0.32 DR T 5.75 0.4605 PF 2.65 2.203 L 16.00 C=120 PT 14.40 (266) F=0 F 0.00 PE 0.00 BN T 16.00 0.0124 PF 0.20 PT 14.60 (265) 265 365 1.049 L 0.75 C=120 PT 12.23 (365) Q 39.87 F=T F 5.00 PE -0.32 DR T 5.75 0.4663 PF 2.68 264 26500 39.60 2.203 L 15.00 C=120 PT 14.59 (265) Q 79.47 F=0 F 0.00 PE 0.00 BN T 15.00 0.0450 PF 0.68 263 26400 38.40 2.203 L 4.00 C=120 PT 15.27 (264) Q 117.87 F=0 F 0.00 PE 0.00 BN T 4.00 0.0934 PF 0.37 PT 15.64 (263) 263 363 1.049 L 0.75 C=120 PT 15.08 (363) Q 21.83 F=T F 5.00 PE -0.32 DR T 5.75 0.1530 PF 0.88 262 26300 117.87 2.203 L 5.00 C=120 PT 15.64 (263) Q 139.69 F=0 F 0.00 PE 0.00 BN T 5.00 0.1279 PF 0.64 PT 16.28 (262) 262 362 1.049 L 0.75 C=120 PT 13.64 (362) O 42.10 F=T F 5.00 PE -0.32 DR T 5.75 0.5156 PF 2.96 25 262D0 139.69 2.203 L 15.00 C=120 PT 16.28 (262) Q 181.79 F=T F 14.00 PE 0.00 BN • T. 29.00 0.2081 PF 6.03 PT 22.31 ( 25) 261 361 Q 49.26 1.049 L 0.75 C=120 PT 18.67 (361) F=T F 5.00 PE -0.32 DR T 5.75 0.6896 PF 3.97 SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 3 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 260 360 1.049. L 7.25 0=120 PT 17.41 (360) Q 23.45 F=T,2E F 9.00 PE -0.32 DR T 16.25 0.1746 PF 2.84 259 260 2.203 L 6.25 C=120 PT 19.93 (260) Q 23.45 F=0 F 0.00 PE 0.00 BN T 6.25 0.0047 PF 0.03 PT 19.96 (259) 259 359 1.049 L 7.25 C=120 PT 17.43 (359) Q 23.46 F=T,2E F 9.00 PE -0.32 DR T 16.25 0.1749 PF 2.84 258 259DQ 23.45 2.203 L 11.75 C=120 PT 19.95 (259) Q 46.91 F=0 F 0.00 PE 0.00 BN T 11.75 0.0170 PF 0.20 PT 20.15 (258) 258 358 1.049 L 0.75 C=120 PT 19.36 (358) Q 24.73 F=T F 5.00 PE -0.32 DR T 5.75 0.1927 PF 1.11 257 258DQ 46.91 2.203 L 9.00 C=120 PT 20.15 (258) Q 71.64 F=0 F 0.00 PE 0.00 BN T 9.00 0.0372 PF 0.33 PT 20.48 (257) 257 357 1.049 L 0.75 C=120 PT 19.68 (357) Q 24.93 F=T F 5.00 PE -0.32 DR T 5.75 0.1957 PF 1.13 256 2570Q 71.64 2.203 L 7.00 0=120 PT 20.49 (257) Q 96.57 F=0 F 0.00 PE 0.00 BN T 7.00 0.0646 PF 0.45 PT 20.94 (256) 256 356 1.049 L 0.75 C=120 PT 20.11 (356) Q 25.20 F=T F 5.00 PE -0.32 DR T 5.75 0.1996 PF 1.15 250 256D0 96.57 2.203 L 1.00 C=120 PT 20.94 (256) Q 121.78 F=TF .14.00 PE 0.00 BN T 15.00 0.0992 PF 1.49 PT 22.43 (250) SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 4 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 255 355 1.049 , L 0.75 C=120 PT 21.42 (355) Q 26.01 F=T F 5.00 PE -0.32 DR T 5.75 0.2116 PF 1.22 250 255 2.203 L 5.00 C=120 PT 22.32 (255) Q 26.01 F=T F 14.00 PE 0.00 BN T 19.00 0.0057 PF 0.11 PT 22.43 (250) 254 354 1.049 L 0.75 C=120 PT 20.37 (354) O 25.37 F=T F 5.00 PE -0.32 DR T 5.75 0.2020 PF 1.16 253 254 2.203 L 11.00 C=120 PT 21.21 (254) Q 25.37 F=0 F 0.00 PE 0.00 BN T 11.00 0.0054 PF 0.06 PT 21.27 (253) 253 353 1.049 L 0.75 C=120 PT 20.43 (353) O 25.40 F=T F 5.00 PE -0.32 DR T 5.75 0.2025 PF 1.16 252 253D0 25.37 2.203 L 14.00 C=120 PT 21.27 (253) Q 50.77 F=0 F - 0.00 PE 0.00 BN T 14.00 0.0197 PF 0.28 PT 21.55 (252) 252 352 1.049 L 0.75 C=120 PT 18.03 (352) O 48.41 F=T F 5.00 PE -0.32 DR T 5.75 0.6676 PF 3.84 24 252DQ 50.77 2.203 L 9.00 C=120 PT 21.55 (252) Q 99.17 F=T F 14.00 PE 0.00 BN T 23.00 0.0678 PF 1.56 PT 23.11 ( 24) 251 351 1.049 L 0.75 C=120 PT 19.36 (351) O 50.16 F=T F 5.00 PE -0.32 DR T 5.75 0.7131 PF 4.10 PT 23.14 (251) 35 261 2 203 • :L 121.50 C=120 PT 22.31 (261) Q 48.04 F=0/2E,T F 28.00 PE 0.00 BL3 T 149.50 0.0177 PF 2.65 PT 24.96 ( 35) SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 5 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 25 261 2.203 L 1.00 C=120 PT 22.31 (261) O 1.22 • F=T.2E F 28.00 PE 0.00 BL3 T 29.00 0.0000 PF 0.00 • 250 25D0 142.41 3.314 L 6.00 C=120 PT 22.31 ( 25) O 143.63 F=0 F 0.00 PE 0.00 CM4 T 6.00 0.0184 PF 0.11 24 250D0 147.79 3.314 L 10.00 C=120 PT 22.42 (250) O 291.42 F=0 F 0.00 PE 0.00 CM4 T 10.00 0.0682 PF 0.68 251 24D0 -278.23 2.203 L 5.00 C=120 PT 23.10 ( 24) O 13.19 F=T F 14.00 PE 0.00 BL2 T 19.00 0.0016 PF 0.03 43 251DQ 50.16 2.203 L 42.67 C=120 PT 23.13 (251) O 63.35 F=0 F 0.00 PE 0.00 6L2 T 42.67 0.0296 PF 1.26 PT 24.39 ( 43) 26 25 3.314 L 16.00 C=120 PT 22.31 ( 25) Q 39.38 F=0 F 0.00 PE 0.00 CM4 T 16.00 0.0017 PF 0.03 36 26 2.203 L 134.50 C=120 PT 22.34 ( 26) Q 39.38 F=T,5E/2E,T F 77.00 PE 0.00 BL3 T 211.50 0.0123 PF 2.60 35 36 3.314 L 16.00 C=120 PT 24.94 ( 36) O 39.38 F=0 F 0.00 PE 0.00 CM5 T 16.00 0.0017 PF 0.03 34 35D0 48.04 3.314 L 16.00 C=120 PT 24.97 ( 35) O 87.41 F=0 F 0.00 PE 0.00 CM5 T 16.00 0.0074 PF 0.12 29 34D0 25.73 3.314 L 13.50 C=120 PT 25.09 ( 34) Q 113.15 F=0 F 0.00 PE 0.00 CM5 T 13.50 0.0119 PF 0.16 PT 25.25 ( 29) 19 24 3.314 1 :13.50 C=120 PT 23.10 ( 24) Q 377.41 F=0 F 0.00 PE 0.00 CM4 T 13.50 0.1101 PF 1.49 PT 24.59 ( 19) SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 6 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 44 43 2.203 L 33.33 C=120 PT 24.40 ( 43) O 38.20 F=0 F 0.00 PE 0.00 8L2 T 33.33 0.0116 PF 0.39 42 44D0 -25.73 2.203 L 16.00 C=120 PT 24.79 ( 44) Q 12.47 F=T F 14.00 PE 0.00 BL5 T 30.00 0.0015 PF 0.05 PT 24.84 ( 42) 41 43 O 25.15 34 44 Q 25.73 2.203 L 16.00 C=120 PT 24.40 ( 43) F=T F 14.00 PE 0.00 BL4 T 30.00 0.0054 PF 0.16 PT 24.56 ( 41) 2.203 L 39.00 C=120 PT 24.79 ( 44) F=0/T F 14.00 PE 0.00 BL2 T 53.00 0.0056 PF 0.30 PT 25.09 ( 34) 42 41 2.203 L 46.42 C=120 PT 24.56 ( 41) Q 17.81 F=T,5E F 49.00 PE 0.00 BL1 T 95.42 0.0028 PF 0.27 33 42D0 12.47 2.203 Q 30.28 BL1 L 39.00 C=120 PT 24.83 ( 42) F=0/T F 14.00 PE 0.00 T 53.00 0.0076 PF 0.40 PT 25.23 ( 33) 23 41 2.203 L 47.67 C=120 PT 24.56 ( 41) Q - 7.34 F=T F 14.00 PE 0.00 BL1 T 61.67 0.0005 PF 0.03 PT 24.59 ( 23) 23 19 3.314 L 2.50 C=120 PT 24.59 ( 19) Q 32.11 F=0 F 0.00 PE 0.00 CM4 T 2.50 0.0012 PF 0.00 22 23DQ 7.34 3.314 L 16.00 C=120 PT 24.59 ( 23) Q 39.44 F=0 F 0.00 PE 0.00 CM4 T 16.00 0.0017 PF 0.03 32 22DQ -20.96 2 203 L 122.17 C=120 PT 24.62 ( 22) Q 18.48 F=T,3E/3E,T 'F '•'70.00 PE 0.00 BL T 192.17 0.0030 PF 0.58 PT 25.20 ( 32) SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 7 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From'To GPM IN Devices Ft PSI/Ft PSI 21 22 3.314 L 16.00 C=120 PT 24.62 ( 22) Q 20.96 F=0 F 0.00 PE 0.00 CM4 T 16.00 0.0005 PF 0.01 31 21 2.203 L 120.00 C=120 PT 24.63 ( 21) Q 20.96 F=T/T F 28.00 PE 0.00 BL T 148.00 0.0038 PF 0.56 32 31 3.314 L 16.00 C= Q 20.96 C=120 PT X�,.19 ( 31) 5 F=0 F 0.00 PE 0.00 CM5 T 16.00 0.0005 PF 0.01 33 32130 18.48 3.314 L 16.00 C=120 PT 25.20 ( 32) Q 39.44 F=0 F 0.00 PE 0.00 CM5 T 16.00 0.0017 PF 0.03 29 33D0 30.28 3.314 L 2.50 C=120 PT 25.23 ( 33) Q 69.72 F=0 F 0.00 1 PE 0.00 CM5 T 2.50 0.0043 PF 0.01 28 29D0 113.15 3.314 L 37.00 C=120 `:PT 25.24 ( 29) Q 182.87 F=2E/T F 45.00 'PE 0.00 CM3 T 82.00 0.0288 PF 2.36 27 28 3.314 L 11.54 C=120 PT 27.60 ( 28) 0 182.87 F=E F 11.00 PE 5.00 CM3 T 22.54 0.0288 PF, 0.65 16 27 3.314 L 12.75 C=120 PT 33.25 ( 27) Q 182.87 F=T F 23.00 PE 0.00 CM3 T 35.75 0.0288 PF 1.03 6 16 3.314 L 191.50 C=120 PT 34.28 ( 16) 0 182.87 F=T,4E F 67.00 PE 0.00 CM1 T 258.50 0.0288 PF 7.44 5 6 3.314 L 12.04 C=120 PT 41.72 ( 6) Q 182.87 F=T F 23.00 PE 0.00 CM T 35.04 0.0288 PF 1.01 PT 42.73 ( 5) 18 19 3.314 L Q 345.30 F=2E/T F CM2 T 37.00 C=120 PT 24.59 ( 19) 45.,00 PE 0.00 82:00 0.0934 PF 7.66 SUBMITTAL SERIAL N0:2244HY10 HYUNDAI T.I. SFS JOB NO. T1-119 DENSITY : .15 GPM / 1500 SQ. FT. FILE NAME : T1119 05-11-1999 PAGE 8 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 17 18 3.314 L 11.54 C=120 PT 32.25 ( 18) Q 345.30 F=E F 11.00 PE 5.00 CM2 T 22.54 0.0934 PF 2.11 . 5 17 3.314 L 2.29 C=120 PT 39.36 ( 17) Q 345.30 F=T,E F 34.00 PE 0.00 CM2 T 36.29 0.0934 PF 3.39 4 5D0 182.87 4.310 L 10.63 C=120 PT 42.75 ( 5) Q 528.17 F=BV F 12.00 PE 4.61 FR T 22.63 0.0570 PF 1.29 2 4 8.265 L 35.00 C=140 PT 48.65 ( 4) Q 528.17 F=E F 19.00 PE 0.00 UN2 T 54.00 0.0018 PF 0.10 1 2 8.265 L 0.01 C=120 PT 48.75 ( 2) Q 528.17 F=0 F 0.00 PE 5.00 UN1 T 0.01 0.0024 PF 0.00 COMMENT: 11.54 FT SLOPE ADDED TO REPRESENT 5 PSI LOSS THRU COMMENT: 8 INCH FEBCO 850 - DCVA 0 1 8.265 L 25.00 C=140 PT 53.75 ( 1) Q 528.17 F=T,GV F 58.00 PE 0.00 UN T 83.00 0.0018 PF 0.15 COMMENT: 250 GPM ADDED AT NODE 0 FOR OUTSIDE HOSE ALLOWANCE. PT 53.90 ( 0) PO Box 3932 Seattle WA 98124-3932 206-234-5700 Fire Com NW, LLC Battery Calculation Work Sheet Project: Dr Timmerman TI — Fort Dent III Office Building 7100 — Fort Dent Way — Suite 270 Tukwila WA 98188 This project consists of a tenant improvement project for an existing fire alarm system. The building is fully sprinklered. This scope of work will include installing 10 new signaling devices to the existing fire alarm system. This battery calculation work sheet is for the existing power supply, 1 existing device and 10 new devices. Qty Part # and description Supervised Current mA Alarm Current mA 1 5495 Power supply 75 175 2 NS Horn strobe 0 268 9 RSS Strobe 0 369 Subtotal 75 812 Total battery power hours x24 x.083 Subtotal 1800 67 Safety factor - 10% + 180 + 7 Total 1980 ma 74 ma Total Current Required 2054 ma or 2.1 amps Battery size used: 2ea - 12volt, 7amp PAD NOV - 4 2005 Tukwila Fire �Zd/1F2 .ris- FIRE SYSTEM ACCESSORY Firepower 5495 fad Distributed Power Module In an emergency, you need maximum power The Firepower 5495 Distributed Power Module by Silent Knight is the most - powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, Wheelock and Faraday — what you need to drive power-hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need Firepower 5495. Call Silent Knight today for more information at 1-800-446-6444. Firepower 5495 Distributed Power Module The firepower 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features • UL Listed for 6 amps of notification power • Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems • Dip switches allow for easy reconfiguration • 24 VDC filtered output voltage • Four power -limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B • Additional continuous auxiliary output • 3 amps per output circuit • 2 inputs; 2 Class B or 2 Class A • Ground fault detector/indicator • • • • • • • Independent trouble relay AC Toss delay option shuts off power to non-essential high -current accessories like magnetic door holders Built-in synchronization for appliances from System Sensor®,Gentex®, Wheelock and Faraday Stand alone operation. Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized, UL Listed notification devices UL 864 & 1481 listed • CSFM approved • ANSI Cadence pattem output capability built-in Connection to Local Fire Control Firepower 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end -of -line resistor is also connected across two terminals on the Firepower 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7k) end -of -line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one Firepower 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. Firepower 5495 Distributed Power Module )1` b SILENT KNIGHT FIRE SYSTEM AeCESSORY Firepower 5495 Distributed Power Module 4JA) Supervision Firepower 5495 supervises a variety of functions including: • Low AC power. • Low battery condition. • Earth ground fault. • Auxiliary output power limit condition. • EOL supervision trouble or power limited condition at an output. When a trouble condition occurs, Firepower 5495 creates a trouble condition on the host control signal circuits to which it is connected. Firepower 5495 still maintains the ability to be activated by the host control. In addition, the 5495 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. Electrical Specification AC Input: 120 VAC at 2 amps Output: 24 VDC at 6 amps Current: Standby Alarm Auxiliary power circuit: Notification circuits: Output configuration: Amps per output circuit: Notification circuit output: No. of inputs Input configuration: 75 mA 175 mA 1 4 2 Class A (Style Z) 4 Class B (Style Y) (1 Class A & 2 Class B) 3.0 (6.0 amps total) 20.4 to 27.3 VDC @ 3.0 amps each, 4.7 kg/ EOL resistor required on each Class B circuit 2 2 Class B or 2 Class A Input voltage range: 9 - 32 VDC Battery charging capacity: 33.0 AH Ambient Temp.: 32° to 120° F 0° to 49° C Mechanical Dimensions: 12.25" W x 16" H x 3"D(30.88cmW x 40.64 cm H x 7.62 D cm) Indicator Lights AC power on : Green Battery trouble: Yellow Ground fault: Yellow Aux Trouble: Yellow Output troubles (1-4): Yellow Approvals: UL: 864 & 1481 NFPA: 72 CSFM Model 5495 Block Diagram Signal Circuit Output Signal Circuit Output Signal 1 input Signal 2 input (Optional) 120 VAC Local Fire Control Distributed Power Module 5495 Trouble Output (Alternative to notification circuit trouble.) Signal 1 Signal 2 Signal 3 Signal 4 Aux. Power SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350395, Rev. 04/02 Copyright 0 2002 Silent Knight • phP UVI SLY] rTr" FIRE ALARM SYSTi EYS L �f� O Helping People Take Actions' SL 1Dr® , ❑ '� j ( ( 71, A Family of Multi -Candela Appliances`" Description The Series NS Hom Strobe Appliances will satisfy virtually all requirements for indoor, wall mount applications. The Series NH Horn and the horn portion of the Series NS include a selectable continuous horn tone or temporal pattern (Code 3) with selectable dBA settings of 90 or 95 dBA. Strobe options include 1575cd or Wheelock's patented Multi -Candela strobe with field selectable candela settings of 15/30/75/110cd. These versatile Horn Strobe Appliances may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules or Wheelock's PS-12/24-8MP Power Supply with patented Sync Protocol. Additionally, the audible may be silenced while maintaining strobe activation. All models of the Series NS and NH are designed for maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest requirements of NFPA 72/ANSI 117.1/UFC and UL Standards 1971 and 464 as well as meeting ADA requirements concerning photosensitive epilepsy. Wheelock's patented 2 -Wire Series NS Hom Strobes and Series NH Horns offer more features with low current draw. Copyright 2003 Wheelock Inc. All rights reserved. SERIES NS SINGLE & MULTI -CANDELA HORN STROBE APPLIANCES SERIES NH HORNS Series NH 1 Series NS X11 . Multi -Candela Indicator (bottom of Strobe Lens) Features • Approvals include: UL Standard 1971, UL Standard 464, New York City (MEA), California State Fire Marshal (CSFM) and Factory Mutual (FM) Pending: Chicago (BFP) • ADA/NFPA/UFC/ANSI compliant • Complies with OSHA 29, Part 1910.165 • Field Selectable Candela Settings 15/30/75/110cd (24 VDC Multi -Candela models) or 1575cd in 12 or 24 VDC • Selectable Continuous Horn or Temporal (Code 3) • 2 Selectable dBA settings of 90 and 95 dBA in both tones • Patented Universal Mounting Plate • 12 and 24 VDC models with llL"Regulated Voltage" using filtered DC or unfiltered VRMS input voltage • Wall Mount • NH horn is selectable 12 or 24 VDC in 1 unit • Synchronize with Wheelock SM, DSM Sync Module or Wheelock PS-12/24-8MP Power Supply with built-in sync protocol • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range'. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0'C to 49°C) and maximum humidity of 93% (t 2%). • Series NH homs are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL Standard 1971 Model Input Voltage VDC Regulated Voltage Range VDCIFWR Strobe Candela (CD) NS-24MCW 24 16.0 - 33.0 15/30/75/110 NS -241575W 24 16.0 - 33.0 15 (75 on Axis) NS -121575W 12 8.0 -17.5 15 (75 on Axis) Table 2: dBA Ratings for Series NS/NH Hom Description Volume Reverberant dBA @ 10it per UL 464 Anechoic dBA @ 10 ft 12VDC 24VDC 12VDC 24VDC Continuous Horn High 83 87 89 95 Low 76 81 84 90 Code 3 Hom High 79 82 89 95 Low 72 76 84 90 Table 3: Average RMS Current Series NS/NH 24 VDC Audible Wall Mount Audible Strobe Models NH -12/24 NS 241675W NS-24MCW @24VDC 16/76cd 1Scd 30cd 75cd 110cd High (95) dBA 16VDC 0.019 0.120 0.077 0.113 0.195 0.268 24VDC 0.028 0.094 0.065 0.087 0.134 0.174 33VDC 0.039 0.102 0.069 0.082 0.117 0.134 Low (90) dBA 16VDC 0.017 0.116 0.070 0.106 0.188 0.261 24VDC 0.022 0.093 0.052 0.072 0.126 0.168 33VDC 0.027 0.078 0.045 0.060 0.097 0.114 Series NS/NH 12VDC Audible Wall Mount NH -12/24 Aud/Strobe @12V NS -121576W High (89) dBA 8VDC 0.013 0.341 12VDC 0.019 0.251 17.5VDC 0.024 0.216 Low (84) dBA 8VDC 0.010 0.324 12VDC 0.015 0265 17.5VDC 0.018 0.188 *Average RMS Current is per UL average RMS method and Average Mean Current is per UL average mean method. NH models use average mean current. For rated In Rush and Peak current across the UL listed voltage range for both filtered DC and unfiltered VRMS (FWR), see installation instructions. SYNC MODULES/POWER SUPPLY Model Number Order Code Input Voltage (VDC) *Average Mean Current (I24VDC Mounting Options SM -1224.8 6369 24 .028 W DSM -12248 6374 24 .035 W PS-1224.8MP 3046 120/220 VAC (a 50/60 Hz; 5.0 amps maz NOTES: SM Sync Module is rated for 3.0 amperes 24 VDC; DSM Sync Module is rated for 3.0 amperes per circuit The maximum number of interconnected DSM Modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. Refer to Data Sheet S9000 or Installation InstructionsPS-12/24-8MP Power Supply. A WARNING: CONTACT WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS (P83983) SERIES NS-24MCW, (P84234) SERIES NS -12 AND 24 VDC SINGLE CANDELA MODELS, (P83600) SERIES NH AND "GENERAL INFORMATION" SHEET(P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILLAFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCES OR FUSES. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • THESE APPUANCESARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF. • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITYSHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams# NS/NH APPUANCE FROM + + TO NEXT PRECEDING - y APPLIANCE APPLIANCE, SM/DSM, ■1 OR EOLR PS-12124-8MP OR FACP SIGNAL NS AND NH APPLIANCES SYNCHRONIZED WITH DSM MODULE DUAL CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE ari6YNCRICOULE NS AND NH APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILENCE FEATURE F A SM Strobl NAC Circuit + STROBE O1 STROBE I1 O +Auditd. EOLR Audib b -Audlbl. NAC Circuit NOTE: NS/NH must be set on Code 3 horn tone to achieve synchronized temporal (Code 3) tone. Refer to installation instruction (P83983, P83600 respectively). *For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the PS-12/24-8MP Power Supply refer to Installation Instructions P84333. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). ARCHITECTS AND ENGINEERS SPECIFICATIONS The audible/visual notification appliances shall be Wheelock Series NS Hom Strobe appliances and Series NH Hom appli- ances or approved equals. The Series NS appliances shall meet and be listed for UL Standard 1971(Emergency Devices for the Hearing -Impaired for Indoor Fire Protection Service). The Series NH Hom shall be UL Listed under Standard 464 (Fire Protective Signaling). The hom strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of two (2) field selectable settings for dBA levels (90 and 95 dBA) and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series NS shall be of low current design. Where wall mount, Multi -Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15/30/75/110 candela. The selector switch for selecting the candela setting shall be tamper resistant The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-12/24-8MP Power Supply with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (Le., contacts remain closed), the strobes shall revert to a non -synchronized flash -rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series NS Hom Strobes and NH hom shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single -gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. PECIFICATION & ORDERING INFORMATION Model Order Code Strobe Candela Non- Sync Sync w/ SM, DSM or PS-12124-8MP 24 VDC 12 VDC 2 WIRE Mounting OptIo Agency Approvals UL MEA CSFM FM BFP NS-24MCW-FR 9404 15130/75/110 X X X - X B,D,E,F,GH,J,N,O,R,X X X X X X NS-24MCW-RN 9405 15/30/75/110 X X X - X B,D,E,FAH,J,N,O,R,X X X X X X NS -241575W -FR 7806 15 (75 on Axis) X X X - X B,D,E,F,GH,J,N,O,R,X X X X X X NS -121575W -FR 7816 15 (75 on Axis) X X - X X B,D,E,F,c H,J,N,O,R,X X X X X X NH -12/24-R 7449 24V X X X X X B,D,E,F,GH,J,N,O,R,X X X X X X Note: Models are ava.lable in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA National Sales Office 800-631-2148 Canada 800-397-5777 E -Mail: I nfo@wheelockinc.com http://www.wheelockinc.corn "emu Member Distributed By: 273 Branchport Avenue • Long Branch, NJ 07740 • TEL: 732-222-6880 • FAX: 732-222-2588 S2100 10/03 E CLQ r 1 � � Helping People Take Actions" DESCRIPTION Wheelock's patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or Wheelock's Patented MCW multi -candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi - candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules or the PS-12/24-8CP and PS-1224-8MP Power Supplies with Wheelock's Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA72. Wheelock's Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim fortheAppliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi -Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with Wheelock's SBL2 surface backbox. For Weatherproof Series RSS See Datatsheet S9004 Copyright 2004 Wheelock, Inc. All rights reserved. SERIES RSS & RSSP SINGLE & MULTI -CANDELA STROBES & STROBE PLATES ars ,,.r. Series RSS Series RSSP RSS Round 71,ler;:, /117011111111 Multi-Candella Indicator (bottom of Strobe Lens) Features • Approvals include: UL Standard 1971, NewYork City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information • ADA/NFPA/UFC/ANSI compliant. Meets OSHA29 Part 1910.165 • Wall mount Multi -Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. Single Candela models are available in 1575cd • Ceiling mount Multi -Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL"Regulated Voltage" using filtered (DC) or unfiltered VRMS input voltage • Synchronize using Wheelock's sync modules or power supplies with built-in sync protocol • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All wamings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 species a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series RSS & RSSP Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 93% (t 2%). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* Product RSSIRSSP - Wall Mount RSS - Ceiling Mount RSSIRSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24 vdc 0.060 0.041 0.063 0.109 0.140 0.195 0270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSSIRSSP RSSIRSSP * RMS current ratings are per UL average RMS method. UL max current 24VDC Wall Mount rating is the maximum RMS current within the listed voltage range (16-33v Models 121575W for 24v units). For strobes the UL max current is usually at the minimum is usually at 12 vdc 0.152 listed voltage (16v for 24v units). For audibies the max current the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, UL max* 0.255 see installation instructions. Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Muttitone Appliances AMT, MT Homs AH, NH, HS Motor Bells MB-G6/G10 Speakers ET -1010/1080, E70, ET70 Chimes CH70 A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIORTO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH ANDAMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams # SERIES RSSIRSSP APPLIANCE FROM PRECEDING ± APPUANCE, SYNC MODULE, POWER SUPPLY OR FACP + TO NEXT APPLIANCE OR EOLR SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT STROBE NAC CIRCUIT OUT DSM TROBE NAC CIRCUIT RETURN STROBE/PLATE ASSE MBLY AUDIBLE& VISIBLEAPPLIANCEOPERATE IN UNISON FROM PRECEDING - APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP TO NEXT + APPLIANCE OR EOLR ALVISIE STROBE/PLATE ASSE M B LY AUDIBLE & VISIBLEAPPLIANCE OPERATE INDEPENDENTLY STROBE APPLIANCE SERIES RSSIRSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM SERIES RSS/RSSPAPPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES F A c P Strobe NAC Cir. DSM #1 DI z m - I DSM #2 1 sy+nc rozar Sicairmit DSM #3 DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES RSS/RSSP A PPUANC ES SYNCHRONIZED WITH PS-12/24-8CP or PS-12/24-8MP F A C P OUTPUTS 1-4 4 -CLASS .a. OR 2 -CLASS S.d.s PS-12/2441AP EOLR • For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for PS-12/24-8MP. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (N FPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi -Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be speed when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-12/24-8CP and PS-12/24-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non -synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single -gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi -Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. s and Ordering Information Model Order Code Wal Mount Ceiling Mount Non -or Sync Sync wf SI /,DSM PS -12/2 8CPIMP Strobe Candela 24 VDC 12 VDC # Model Color RED # Model Color WHITE Mounting Options"' uare or Round Agcy Approvals UL MEA CSFM FM BFP RSS24MCW-FR 9400 X - X X 15/30/751110 X - X - B,D,E,F,GH,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - X X 15/30/75/110 X - - X B,D,E,F,GH,J,N,O,RX Square X X X X X RSS-241575W-FR 7471 X - X X 15 (75 on /Ws) X - X - B,D,E,F,GH,J,N,O,RX Square X X X X X RSS-241575W-FW 7788 X - X X 15 (75 onAkds) X - - X B,D,E,F,GH,J,N,O,RX Square X X X X X RSS-121575W-FR 7476 X - X X 15 (75 on Abs) - X X - B,D,E,F,GH,J,N,O,RX Square X X X X X RSS-121575W-FW 7468 X - X X 15 (75 on Ards) - X - X B,D,E,F,GH,J,N,O,RX Square X X X X X RSS-24MCC-FW 3158 - X X X 15130/7595 X - - X B,D,EF,GH,J,N,O,RX Square X X X X * RSS-24MCCER 3157 - X X X 15130//595 X - X - B,D,E,F,GH,J,N,O,R)k Square X X X X * RSS-24MCCR-FW 3160 - X X X 15/30/7595 X - - X B,D,E,F,GH,J,N,O,RX Round X X X X * RSS-24MCCR-FR 3159 - X X X 15/30/7595 X - X - B,D,E,F,GH,J,N,O,RX Rood X X X X * RSS24MCCHIW 3461 - X X X 115/177 X - - X B,D,E,F,GH,J,N,O,RX Square X X X * * RSS24MCCHR-FW 3463 - X X X 115/177 X - - X B,D,E,F,GH,J,N,O.RX Round X X X * * RSS-24MCWHFR 3465 X X X 135/185 X X B,D,E,F,GH,J,N.O,RX Square X X X * * RSSWP-2475W-FR" 9013 X - X X 180 a 77°F 75at31°F X - X - B.D,E,F,GH,J,N,O,RX Square X X X X * RSSwP-2475W.fW* 3034 X - X X 180 @ 77°FX 75@31'F - - X B,D,E,F,GH,J,N,O,RX Square X X X X * RSSP-121575W-FR 7798 X - X X 15 (75 on Aids) - X X - 0,EZ Square X X X X X RSSP-24MCWFR 9402 X - X X 15/30/75/110 X - X - D,EZ Square X X X X X RSSP-241575WFR 7793 X - X X 15 (75 on Aids) - - X - D,EZ Square X X X X X RSSP-24MCWH-FR 9482 X X X 135/185 X X B,D,E,F,GH,J,N,O,f,k Square X X X * * 1 Models are avalable in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3 YEAR WARRANTY Made in USA NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 E-mail: Infocwheelockinc.com http://www.wheelockinc.com IrCZNI Member *PENDING Distributed By: WHEELOCK, INC. • 273 BRANCHPORTAVE • LONG BRANCH, N.J. 07740.732-222.6880 • FAX: 732-222-2588 80410 05/05 021. DR.'S LAV. UA LO t 1 1 2 a 4 k SJPPL" C BiNET AREA OF WORK IIIA'IIR,1 rm. .-� TO EXISTING PS o-9 TANTS 0 • DIE4. H �rTh OP N4 oP N,. r OP #2 b GP NI 1 A9A H 7 PT.'S LAV. 5 it PHOTO CCN4LLTATION STAFF t-OUNGE WASHER/ DRYER STACKED Hd3J/NJd VNC,.: 1 1 1 F— PS FIRST FLOOR FIRE ALARM RISER DIAGRAM SCALE: NONE 04 FIRE ALARM PLAN K7 SCALE: 1/8"-1"-0" EQUIPMENT LEGEND ADEM DESCRIP110N PART NUNIBER DESCIBPSON BASKS= BASKB ®Q 2 NS HORN STROBE 4 SQUARE X 1-7/8' DEEP ID 9 RSS STROBE 4 SQUARE X 1-7/8" DEEP WIRE LEGEND TWE DESCRIP110N A 18 AWG, 2 CONDUCTOR 'FPLP' JACKETED CABLEI 8 14 AWG, 2 CONDUCTOR 'FPLP' JACKETED CABLEI C 18 AWG, 4 CONDUCTOR 'FPLP' JACKETED CABLEI r GENERAL NOTES: 1. ALL WORK 1S TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. 2. WIRING METHOD 1S TO 8E OPEN CABLING EXCEPT WHERE R 18 EXPOSED AND BELOW SEVEN FEET • THEN IT 18 TO BE IN CONDUIT. 3. ALL JUNCTION BOXES, COVERS, AND BACK BOXES ARE TO BE PAINTED RED. 4. ALL INDOOR HORNS, STROBES, HORN STROBES, AND MINI HORN STROBES ARE TO BE MOUNTED 80" ABOVE THE FLOOR OR W BELOW THE CEILING, WHICHEVER 18 LOWER. 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE OF FLAME AND HOT GASES. FIRE COM NW LLD PO Box 3832 3.attle WA 981244932 205.2344700 DATE: 10/25/05 PROJECT HAW: DRAWN: CEA DR. TIMMERMAN T.I. CHECKED: JD 7100 Fort Dent Way - Suite 270 APPROVED 8Y JD Tukwila, WA 98188 SHEET ME: SCALE: 1/8"-1-0" FIRE ALARM PLAN NO. DATE REVISION BY JOB NUMBER: 05-174 FA -1 of 1 A comp!et_d, = , T!'kifv;la Fire De0a; ...;~;._ Certificate musc be esen.pd to ;he InF--..:ector prior to :. con nee . ent Acc ? o= m Ice any moire L:i on c\,,steirs. iinnt�aRe-iinsp Re -inspection Fee and ler minatof f of the (.e..:tino. !UKWILA FIRE DEPAr<t-ivttldl Please call: 575-4407 ?-nd give this job No..0 and exact address for shut. ouwn or restoration approval. ACCEPTED Witr'out Comments As Noted In Red Per The Attached Letter iThese plans have been reviewed by The Tukwila Fire Prevention Buress_i 'ipr conformance with current city i standards. Acca::'F cc:s subject to errors and omissions which o., not wuihonze violations of adopted u stand: -.rd Inn c-"': r.c=:•s. The responsibility for the adeo- ~' c` -; 11 i tr, tiotslly with the designer. Addit;o . (.--.;- ,..„n 6 revisions zu these drawings after i Ithis d 4 \P.! \ ! ,ic ,"‘s acceptance and will require a 4 resubm._«i' c .t. -ed ara'rrings for subsequent approval. i Final acceptance is subject to field test and inspection by r, The Tukwila Fire PreventionBureau. ' 1. Date: /// O By: L/ -/- c-70 g Symbol Legend SYMBOL DESCRIPTION MANUFACTURER PART NUMBER MODEL QUANTITY USER TEXT UL FM NAG „ Ex 6 AMP NAC POWER SUPPLY W/SYNC SILENT KNIGHT SK 5495 5495 1 EX Listed 5495 POWER EXTENDER PANEL MAIN MOTHER BOARD P PULL, DUAL ACTION SILENT KNIGHT PS -DA PS -DA 2 STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD S8012 N/A DI VGD HORN/STROBE, EXCEDER 24V, M -C, RED, WALL. COOPER WHEELOCK HSR HSR 14 EX S2852 Approved E. STROBE, EXCEDER 24V, M -C, RED, WALL COOPER WHEELOCK STR STR 1 EX S2852 Approved "0' STROBE, EXCEDER 24V, M -C, RED, CEILING COOPER WHEELOCK STRC STRC 7 1 S2652 Approved )'.:( HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING COOPER WHEELOCK HSRC HSRC 2 Total Peripheral Stby S2652 Approved EOL 4.7K IZ ar EOL 4.7K SILENT KNIGHT EOL -4.7 EOL -4.7 1 19.2264V (0.0195V) 9 • 15CD EOL 4.7K f2 \ / 15CD / 75CD Battery Calculations for Panel: P1: EX Part No:SK 5495 - 6 AMP NAC POWER SUPPLY W/SYNC Job number: 817-0652 Job name: TABOR Address 1: 7100 FORT DENT WAY, SUITE 100 Address 2: TUKWILA, WA 98188 Phone; 253-833-1248 Fax: Designing engineer: MATT CARLMAN Authority having jurisdiction: CITY OF TUKWILA Part No. Qty. Description Standby Total Standby Alarm Total Alarm FAX: SK 5495 Panel Equipment WA ST LICENSE: FIRESWI055LW 20.2V SK 5495 MB 1 5495 POWER EXTENDER PANEL MAIN MOTHER BOARD 75.0000mA 75.0000mA 205.0000mA 205.0000mA 2 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD Total Panel Stby 75.0000mA Total Panel Alarm 205.0000mA 3 STRC Peripheral Devices 96'-0 61.0000mA 19.4414V (0.3543V) STRC 7 STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 61.0000mA 427.0000mA HSRC 2 HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 148.0000mA 296.0000mA EOL -4.7 1 EOL 4.7K (Notification) 0.0000mA 0.0000mA 0.0000mA 0.0000mA 7 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 75CD Total Peripheral Stby 0,0000mA Total PeriphAlarm 723.0000mA 8 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 26'-0 61.0000mA 19.2264V (0.0195V) 9 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD Total Standby Amps 75.0000mA Total Alarm Amps 928.0000mA Standby time: 24 Hrs 1.8Ah Alarm time: 5 Min 0.077Ah Battery requirement: 1.877Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 2.253Ah 75CD / \ / 5b fib o Gos so Circuit Calculations Panel: P1 Card: 00 Circuit:SIG4 Circuit Name: SIG4 Circuit Type: Notification . Terminal Voltage: 20.2V:DC Amperage: 2.0000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop FAX: SK 5495 Panel WA ST LICENSE: FIRESWI055LW 20.2V 1 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 16'-0 61.0000mA 20.129V (0.071V) 2 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 87-0 61.0000mA 19.7957V (0.3333V) 3 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 1500 96'-0 61.0000mA 19.4414V (0.3543V) 4 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 13'-0 61.0(300mA 19,3983V (0.0431V) 5 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 16-0 61.0000mA 19.3542V (0.0441V) 6 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 75CD 28'-0 148.0000mA 19.2823V (0.0719V) 7 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 75CD 22'-0 148.0000mA 19.2459V (0.0365V) 8 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 26'-0 61.0000mA 19.2264V (0.0195V) 9 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 11'-0 61.0000mA 19.2223V (0.0041V) EOL -4.7 EOL 4.7K 2'-0 0.0000mA 19.2223V (OV) 311'-0 723.0000mA Total Current: 723.0000mA (Total VOrop Percent:4.84%) Total Voltage Drop : 0.9777V 14/2 15CD 15CD 15CD 15CD 15CD / \ / \ / \ / ,, \ / 0 / \ / \ / \ / \ / v. it 1 : 1)% ; vt cos vs cos co- cos 5495 120V 20 AMP Area 0 sr,. x N >"t"a't.4 'e.r. U,i fi� Y.,::"r".,;5:Y4 :.x „f ;r ) Sret>oi.. ,. ,,., v e. , -"au,•v e i. ).. t.. i. a• ,'r.,.3r a :.Q dri •l4,t , 5 N •,>x, �.' , t}, ,,,c`xi"n� , cd , tfi'J,ti'� �. Isw4,�.`n.x`c" x�^, ,a. iS"UtiA" xfi,nS & 9 to ';• .. .. ,.. <.:� .; ,.. o,.., � ,., x xs, a t�xur c � ,..1,• � ".tr•.�kY�. "%t... 1. :"f, r.'a1.4X ,'c>7' „Xr..•�'n, 1'«,p t• -r Sr .4 ..r �..Sa+v. S.'x. ��+Ui(kr.S.{e7„V,�)td�'Yi~ki „d"d?4,`4 �§'`� Y�. h {`) ,.. .,... ,.. ,o.,. ,,., ,y .• . Y,. �c e x.;.xsu.:a r netc•5 � ��r,... ! ., f:' 1• ,} ), tai, �,. ,{..o<.Sf, r!1,:v`l°/a?{dl .,, YsO, �, x t . „ ., . ,.,,, ,., 5, ' r h ,..F.,. a :.. ft, t, l'.:.Zr~.,>,. n �Yti�c, s;.dt{fi7'�ss,`esYfiSx?y�.x '<z3 lis^.lt}'tS,.%)„atM 4a5;¢,,,=,;.i�S.;N.A.�',. r rv" ♦ rr�uRx�mxn��rx ♦ �,'�r����s ♦ ���r ♦ r��>n��{,�a� ♦ ��>rr�,<���s�sa,�� ♦ i5�x�,��� • a�,,,m.�{:ta�,��; ♦ �ztrr�:r„3,rc�.,�x�,;a ♦ �,,w�.�:nitr{a?��� ♦ a,z��a$�.,„rx,cr� ♦ �,,.�a.^w ��a., ♦ � )rw.<„s„�ca�� ♦ �mr,..,I �t �„� ♦ �� 1 CAUSE SMOKE I HEAT bETECTOSS IuttiNUAEUUCC'STATION _.__-._-.......... -SYSTEM RESIT SidNAL SICENC ... I' N RTAiL1Rg............_ FIRE ALARSI TROU$LE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS_,-_._ -TAMI3Eti SY41TGTl SS-- `WATERFLOW SWITCH FIRE ALARM SYSTEM OPERATIONAL. MATRIX ___._.......SND__..._......_-......Th0U8t.t jSUPERtII50RY MISCELLANEOUS m © A 0 re 6 A 0 01 0 re Pr WIRING DIAGRAM ' Without Comments ® As Noted in Red El Per The Attached Letter ' .ese plans have been reviewed by The Tukwila Fire - vention Bureau for conformance with current City ndards. Acceptance is subject to errors and fissions which do not authorize violiations of adopted :,ndards and ordinances. rhe responsibility for the .equacy of design rests totally with the designer. dditions, deletions or r evisio, is to these drawings after this -date will void this r:,:+:eptance and will require a resubmittal of revis_°ci (1, -Livings for subsequent approval. Final acceptance: is .abject co tleid test and Inspection b\; The Tukwila Fire Preventio: i Bureau. r ')ate: I 0 / I J C By: Permit i''WFUrt 1i.i'.�ir Iq-r-i�� To sc heduie riOr1S Cali 206-575-4407 GENERAL NOTES 1 SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.F.PA., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE INSTALLING NEW FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER SITE CONTACT: TABOR DESIGN/SUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY, SUITE 100 206 FRONTAGE ROAD NORTH, STE TUKWILA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735-0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE: FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735-0113 X NICET LEVEL II 146053 WORK AREA A 1412 FPLP B 1612 FPLP EX EXISTING LOCATION (SWAP FOR NEW DEVICE) WP WEATHER PROOF N NEW DEVICE R RELOCATE • STROBE COVERAGE AREA SHALL BE DEFINED AS 10 FT. CLG, HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd =20x20' 30 cd = 20120' 75 cd = 20'x2e 30 cd = 30130' 75 cd = 30X30' 95 cd = 30'x30' 75 cd = 40X40' 95 cd =40)(40' 110 cd = 40X40' 95cd=50X50' 110cd=50X50' 115cd=501(50' Sciulhein Gsiil Accounting Tax $ervices Skill .<.tiiisv; l Opii,'t (fing%s. 'roup cattle, WA: • aple Gest Alianrrients ". <:-z`: i�arkview Apartment amid ic;r1 ,ra„ .i /ti:,;' u?ton Sea'tii 'rack Merldiari Valley Lob Kwan; Endadon(1 VICINITY MAP SCALE: N.T.S. PAID 1 0 1- 1- M = M_ CO Hca _Z o 1111 Q IDC Z ril t9 corink% 4C Ct Ilki H 0 CS a as ac) elcCCNI CL Fax: (253) 735-0113 N M M co I0 WA ECL# FIRESWI 055LW WA CL# FIRE W 1- 0 cra z O ISSUED_FOR_REVIEW 0 z EW DEVICE COUNT g� 0 0 0 0 0 0 0 0 W N z lz W 1- �r W W 1-- D W W -J W 0 0 a MS -7 SERIES a 0 a W 2 SYSTEM SENSOR SYSTEM SENSOR CEIUNG HORN STROBE OUTDOOR WALL HORN STROBE SYSTEM SENSOR SYSTEM SENSOR J 0 0 I J WSJ ,S (5 0 LL J JsJ LL -J -J m O x w ce PULL STATION SMOKE SENSORS HEAT SENSORS m z 0 z TABOR FIRE ALARM PLAN w z r ct w6 J oOmJ z �� 8 it) t0 O co g. 11 w w ( coo ^( CO C•1 CCJ m i CV H �M Q 1!i U LLIZ o 0 Iii 0 O a. LLco it 1 o; W Ii = J far \ / SIG4.2 /0\ 15CD OFFICE \o/ SIG4.3 / \ 15CD OFFICE \�/ SIG4.4 / \ 15CD OFFICE \ / SIG4.5 /0\ 15CD • ❑ 0 SIG4.6 75CD HUDDLE \�/ SIG4.1 15CD \ SIG4.7 75CD EX 15CD 0 SIG4 EOL 4.7K i2 / SIG4.9 \ 75CD \ / SIG4•8 u• 15CD 7tt�aWSeH�"S,: OFFICE OFFICE 0 GRAND MEETING ROOM ( TABOR iF 1111111 f MIN y{' ' 8' CLE: 118'=1'-0" 12' 20' TRAINING ROOM SUITE 100 FIRE ALARM PLAN GENERAL Ni TES! SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE INSTALLING NEW FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER SITE CONTACT: TABOR DESIGNISUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY, SUITE 100 206 FRONTAGE ROAD NORTH, STE i TUKWILA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735.0113 WA ST LICENSE: FIRESW I140B1 WA ST LICENSE: FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735-0113 X NICET LEVEL II 146053 WORK AREA Drawing reviewed by: Rodrigo G. Quinteros NICET Certification No. 125166 Fire Alarm Systems - Level III Certification Expires: October 1, 2019 A B EX WP N R 1412 FPLP 16/2 FPLP EXISTING LOCATION (SWAP FOR NEW DEVICE) WEATHER PROOF NEW DEVICE RELOCATE • STROBE COVERAGE AREA SHALL BE DEFINED AS 10 FT. CLG. HT. 20 FT. CLO. HT. 30 FT. CLG. HT. 15 cd = 207.:20' 30 cd .205(20' 75 cd = 20'x20' 30 cd = 30'40' 75 cd = 305(30' 95 cd = 305(30' 75cd=40Y40' 95cd=405(40' 110cd=405(40' 95cd=50560' 110 ed=505(50' 115cd=505(50' outh€�fn Gn Accounting& Tax Services, S1dIL Maple Crest Ap rtrilents. ilomed:oo(i.itl l,fior <<:atY tr . cY71 eddi;rn Wiley Lab condo VICINITY MAP: SCALE: N.T.S. ' w F - co 0 206 FRONTAGE ROAD C7f 0 z 5s c ctc WA ECL# FIRESWI 055LW co w 0 0 0 0 N d act 0 0 tY 0 0 0 0 0 0 a N W F LIJ 1--' LLI ~ F 0 W 1-- tW— W J 0 0 OC 6. y MS•7 SERIES 1 SYSTEM SENSOR SYSTEM SENSOR CEILING HORN STROBE OUTDOOR WALL HORN STROBE SYSTEM SENSOR SYSTEM SENSOR c3 1 J 0 0 J WSJ GAMEWELL FCI J W 0t— N 0 Z N fi 3 3 PULL STATION SMOKE SENSORS 0 HEAT SENSORS e rn 0 1 TABOR FIRE ALARM PLAN W z W co 0 a' J otimLLL1 8 c'' v, a W 1�—\ V/ s co I— Z 1 w Q< I— z eto`S 0LL m C V 1—�I— ON-SITE CONTACT: BILLY SHADRIN 206-2989 Q 1 O LCL 1-- W w N - FILE:Tabor Fire Alarm Plans DATE:09/19/19 TIME:15:13:40 - Fire Alarm Symbol Legend SYMBOL DESCRIPTION PART NUMBER _ MODEL QUANTITY _USER TEXT UL______ _FM__ MISCELLANEOUS I Panel Equipment CAUSE 0', (e., 0;0 5 �d �4i Qd �� F� v� v5 �4�P`� Q\Y- \)�+ QS', ., N. ��°gQ40J�QOJ� 4 Q aJQ� p� pcid i 20.4V REMARKS 5495B ;07( HORN/STROBE, 24V, M -C, RED AS-24MCW-FR AS-24MCW-FR 7 EX E5946, S5391 Approved \ / Total Panel Stby 75.0000mA Total Panel Alarm 205.0000mA 3 HSRC Peripheral Devices /o 30CD STROBE, EXCEDER 24V, M -C, RED, CEILING STRC STRC 2 2 S2652 Approved /o 15CD STROBE, EXCEDER 24V, M -C, RED, CEILING STRC STRC 4 STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) S2652 Approved 8 95CD HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING HSRC HSRC 2 0.0000mA S2652 Approved 352.0000mA 6 AMP NAC POWER SUPPLY W/SYNCH 5495 5495 1 0.0000mA Listed 766.0000mA NAC . ® EOL 4.7K S1 EOL 4.7K EOL -4.7 EOL -4.7 1 - - - ._..__....... ...._....__.... Battery Calculations for Panel: P2 Part No:5495 - 6 AMP NAC POWER SUPPLY W/SYNCH Job number: 817-0319 Job name: KEURIG GREEN MOUNTAIN Address 1: 7100 FORNT DENT WAY Address 2: TUKWILA, WA 98188 Phone: (253)833-1248 Fax: (253)735-0113 Designing engineer: MATT CARLMAN Authority having jurisdiction: CITY OF TUKWILA Part No. Qty. Description Standby Total Standby Alarm Total Alarm MISCELLANEOUS I Panel Equipment CAUSE 0', (e., 0;0 5 �d �4i Qd �� F� v� v5 �4�P`� Q\Y- \)�+ QS', ., N. ��°gQ40J�QOJ� 4 Q aJQ� p� pcid i 20.4V REMARKS 5495B 1 5495 POWER EXTENDER PANEL MAIN MOTHER BOARD 75.0000mA 75.0000mA 205.0000mA 205.0000mA 2 0 0 Total Panel Stby 75.0000mA Total Panel Alarm 205.0000mA 3 HSRC Peripheral Devices 38'-0 176.0000mA 19.3624V (0.1447V) STRC 2 STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 85.0000mA 170.0000mA STRC 4 STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 61.0000mA 244.0000mA HSRC 2 HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 176.0000mA 352.0000mA 7 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD Total Peripheral Stby 0.0000mA Total Periph Alarm 766.0000mA 8 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 95CD 10'-0 176.0000mA _SYSTEM RESET - - ..._.... - SIGNAL SILENCE -- .... - --... AC POWER FAILURE FIRE ALARM TROUBLE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS - - - ._..__....... ...._....__.... Total Standby Amps 75.0000mA Total Alarm Amps 971.0000mA Standby time: 24 Hrs 1.8Ah Alarm time: 5 Min 0.081Ah Battery requirement: 1.881Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 2.257Ah ID Without CorrmLerlts As Nater. `�.:.. a Per The Attached Letter These plans have been revieweo to The Tukwila Fire Prevention Bureau for conformance r•:Mich current City standards. Acceptance is subjer7 .vrors and omissions which (.1;,+ 1.10t -al,! r;Orizt ,1;:,i,31:ions of adopted standards anr+ r;:.rifti:0,tr-.°s . The r sxc.nsOility for the adequacy of design totally with the designer. Additions, deletirP r,.,vlsions to these drawings after this date %Mil v-Dlo o.,t3 ;, cceptafce and will rec(uire a resubmittatrnwings for sunsequent approval. Final acceptance iM. F,obiec t to field test and inspection by The Tukwila Fire Prtevent:lon Bureau. Date: /- I I J TUKWILA FIRE DEPARTMENT `e•y�r' - .1 7.1 ":'''''r-575-4407 and - - 'or shut - ort approval. . 95CD D • 15CD 0 . r FIRE ALARM SYSTEM OPERATIONAL MATRIX Device Part No Appliance Desc Distance Current ALARM TROUBLE SUPERVISORY MISCELLANEOUS I Panel CAUSE 0', (e., 0;0 5 �d �4i Qd �� F� v� v5 �4�P`� Q\Y- \)�+ QS', ., N. ��°gQ40J�QOJ� 4 Q aJQ� p� pcid i 20.4V REMARKS 1 STRC SMOKE! HEAT DETECTORS 165'-0 0 0 0 2 0 0 27'-0 85.0000mA 19.5071V (0.1169V) 3 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 95CD 38'-0 176.0000mA 19.3624V (0.1447V) 4 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 30CD 18'-0 85.0000mA 19.3134V (0.0491V) MANUAL PULL STATION STRC 0 0 0 19.1877V 0 0 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 2V-0 61.0000mA 19.1493V (0.0384V) 7 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 11'-0 61.0000mA 19.1333V (0.016V) 8 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 95CD 10'-0 176.0000mA _SYSTEM RESET - - ..._.... - SIGNAL SILENCE -- .... - --... AC POWER FAILURE FIRE ALARM TROUBLE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS - - - ._..__....... ...._....__.... - - ..__... - __.._.... 0 0 - O 0 - _ -- - 0.._ - - - - -- O..O ---- TAMPER SWITCHES 0 0 0 `WATERFLOW SWITCH 0 0 0 0 O 1 15CD 0 . Circuit Calculations Panel: P2 Card: 01 Circuit:SIG2 CircuitName: SIG2 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 2.0000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop FAX: 5495 Panel WA ST LICENSE FIRESWI055LW 20.4V 1 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 165'-0 61.0000mA 19.624V (0.776V) 2 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 30CD 27'-0 85.0000mA 19.5071V (0.1169V) 3 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 95CD 38'-0 176.0000mA 19.3624V (0.1447V) 4 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 30CD 18'-0 85.0000mA 19.3134V (0.0491V) 5 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 57'-0 61.0000mA 19.1877V (0.1256V) 6 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 2V-0 61.0000mA 19.1493V (0.0384V) 7 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 11'-0 61.0000mA 19.1333V (0.016V) 8 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 95CD 10'-0 176.0000mA 19.1225V (0.0108V) 347'-0 766.0000mA Total Current: 766.0000mA (Total VDrop Percent:6.26%) Total Voltage Drop : 1.2775V 15CD 0 30CD 0 95CD D 30CD 0 20 AMP DEDICATED CIRCUIT . . . WIRE DIAGRAM . . . . . Area 0 . GENERAL NOTES I SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST ' U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE INSTALLING NEW FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. FIRE ALARM SYSTEM INFORMATION INSTALLER/SUPPLIER SITE CONTACT: KEURIG GREEN MOUNTAIN DESIGN/SUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C TUKWILA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735-0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735.0113 X FOR FIRE DEPARTMENT USE ONLY APPROVED Bryan Hilfiker NICET III 99709 DNO.ly LOnMby&y,nF llsx Bryan Hilfiker DM:2010A11406.39.000. A B EX WP N R 1412 FPLP 1612 FPLP EXISTING LOCATION (SWAP FOR NEW DEVICE) WEATHER PROOF NEW DEVICE RELOCATE • STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 20'x20' 30 cd = 20'x20' 75 cd = 20'x20' 30 cd = 30'x30' 75 cd = 3D'x30' 95 cd = 30'x30' 75 cd = 404x40' 95 cd = 40'x40' 110 cd =40'x40' 95 cd = 50'x50' 110 cd = 50'x50' 115 cd = 50'x50' WORK AREA aiiufacturers ONinera VICINITY MAP SCALE: N.T.S. PAID' Ail 24 2017 TUKWILA FRF CC. (§ �/ D Fax: (253) 735.0113 WA ECL# FIRESWI 055LW O. 0 m N N 0 z 5 ISSUED_FOR_REVIEW 0 z NEW DEVICE COUNT J 0 z x rn w x w w 1- w 1- 0 w tY w 1- w 1- w 1- x J w 0 a CO MS -7 SERIES w J SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR GAMEWELL FCI GAMEWELL FCI GAMEWELL FCI w w CEILING HORN STROBE OUTDOOR WALL HORN STROBE LL HORN STROBE WALL STROBE PULL STATION SMOKE SENSORS HEAT SENSORS z s 2 • s UUP e KEURIG GREEN MOUNTAIN FIRE ALARM PLAN 0) tti• 0o ON-SITE CONTACT: BILLY SHADRIN 206-361-2989 LCL 1- o w ILLS w w 0 (1) 1-- w w (/) �- FILE:K9urig Fire Alarm Plan.cad DATE:01/23/17 TIME:14:55:12 — RECEPTION CONFERENCE BREAK/COPY ROOM CLOSET OPEN OFFICE STORAGE STORAGE EOL 4.71( O \o \ 30CD 15CD \O / \ MEETING OFFICE OFFICE OFFICE OFFICE MEETING PTN / MUL. PTN / MUL. PTN/MUL. KEURIG GREEN MOUNTAIN 11111 1111 — —.� Sp CA2' LE: 4'118''=18 '0" 12' 20' PTN./ MUL. PTN./ MUL. PTN / MUL. FIRE ALARM PLAN PHONE ' FIRE ALARM SYSTEM OPERATIONAL MATRIX DESIGN/SUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C TUKWILA, WA 98188 ALARM TROUBLE SUPERVISORY MISCELLANEOUS 1 CAUSE a(> a0 JCr cy J ,,(4 A,. ,s1 SOF Ov- Jp �. Pc, �a�F,< �\.P�pP �� �P' 4 �� Q`y Qy4 HiQ, �S �# q< .�Q .� P P P P 0 0 0 C O �t�Q�py1��$`ti g FQ��O�Si`' PGC�`��AN- �Q�0�2O�Q2' co co \f JQ� WA ST LICENSE. FIRESWI055LW REMARKS SMOKE IHEAT DETECTORS 0 0 0 0 0 MANUAL PULL STATION 0 0 0 0 0 SYSTEM RESET 0 SIGNAL SILENCE 0 0 AC POWER FAILURE 0 0 0 FIRE ALARM TROUBLE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS 0 0 0 TAMPER SWITCHES ._._..._......__..._._... 0 0 0 0 ...........__.....-- 0 --- — — ® O. o ---- -- — — — ._--._ `WATERFLOW SWITCH KEURIG GREEN MOUNTAIN 111111 M — ., pp � t SCALEi4118"=180" 20' GENERAL NOTES I SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISKI! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE INSTALLING NEW FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER SITE CONTACT: KEURIG GREEN MOUNTAIN DESIGN/SUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C TUKWILA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833.1248 FAX: FAX: (253) 735.0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE. FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735.0113 X FOR FIRE DEPARTMENT USE ONLY APPROVEb Bryan Hilfiker NICET III 99709 Bryan Hilfiker A B EX WP N R 1412 FPLP 1612 FPLP EXISTING LOCATION (SWAP FOR NEW DEVICE) WEATHER PROOF NEW DEVICE RELOCATE STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 210x20' 30 cd = 2(0x20' 75 cd = 20'x20' 30 cd = 30'x30' 75 cd = 30'x30' 95 cd = 3(0x30' 75 cd = 40'x40' 95 cd = 40'x40' 110 cd = 4(0x40' 95 cd = 500x50' 110 cd = 50 xSO' 115 cd = 50'X50' WORK AREA DIWWb.4nedbyBryan mnm Ok an. Bryan HBBkn. o.i.e Sy. Bem. Wnt IewSWk. eane Of erna II.BryanlieUeSypnmWe.twm .•US Dale 2017.012406,I4.12-0aw nufacturL,r;' Miami VICINITY MAP SCALE: N.T.S. U W 1-- �a RI 0 01 in 0 z z a 0 „le ce z<1...(9co o ti ag: N a. u.u. U Fax: (253) 735-0113 OD c.1 eh CO LK) CS/ WA ECL# FIRES WA CL# FIRESWI 140B1 0 m co z 0 rn ISSUED_ FOR REVIEW z NEW DEVICE COUNT 0 z c z T. w F - x w F- s 1- w F - x 111 0 I- g or � w x w J W 0 5 0 a. a. 0) LL x 5 SYSTEM SENSOR W CEILING HORN STROBE OUTDOOR WALL HORN STROBEI SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR 5 5 W W J J J J W 2 GAMEWELL FCI GAMEWELL FCI WALL HORN STROBE W 0) cr rn J J PULL STATION SMOKE SENSORS HEAT SENSORS co 0 x 5 z 2 -J W EY LL z z 0 2 W LL 0 0 W CONTRACT WITH: z C7 ,- W W < ON-SITE CONTACT: BILLY SHADRIN 206-361-2989 tai :tri 0 r• CO O 0 CD 0 11 Q LL W J V 1-- W +,n 14011 . U W CZ Fire Alarm Symbol Legend GENERAL NOTES 1 SCOPE OF WORK h ,.. c..).,...... c,,, u) DESCRIPTION PART NUMBER MODEL QUANTITY USER TEXT UL FM SYMBOL I;O,< HORN/STROBE, EXCEDER 24V, M -C, RED, WALL HSR HSR 1 R S2652 Approved 1. SYSTEM. WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT ezr 0, re tx = 0) ,ii -4 HORN/STROBE, EXCEDER 24V, M -C, WHITE CEILING HSWC HSWC 1 30CD 82652 Approved APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! Q 0 - Nw STROBE, EXCEDER 24V, M -C, WHITE, CEILING STW STC W 1 • 15CD S2652 Approved 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY ' IQ°epi z 1- c4C co VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING Q N o0G ,�'va I :x+ , il °^fl re^ $,,"'" ' �� w t Withal 1t, f,�irnrnenits TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN gA /y q5 C 4,5� �y _kt° THE SAME RACEWAY. ,.1' � �,iILA FIRE 1.�I PARTHH+�,9'r G 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST ,. �,., , this Fire Permit No. ILL, N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE ,. , .. W ILI -oar CITY STANDARDS. o ®C N IQ. � '•e �' M to e!.. co LIC As I�uter� I.1 Pod 3 3 I ■ Per The Alt, cl �t_�.. _atter W i 1d exact address + 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY < do�n�1cc � >;4 ''° r �� h _se plans have been reviewed l-r�� The Tukwila Fire L',-",ention Bureau for conformance with current City AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT - OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. = 00 --ndards. Acceptance is subject rc�' errors and ,,fissions which do not authorize violations of adopted ;:,ndards and ordinances. The responsibility for the 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION 00 MWC i>A'guacy of design rests totally with the designer, ',c+ditions, deletions orrevisions to these drawings after ,This date will void this acceptance and will require a fesubmittai of revised drawings for subsequent approval. APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. DATE c g cA Final acceptance isvenct to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: i , LI -.1q By: i v''' . 3 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE RELOCATING ONE FIRE ALARM NOTIFICATION n W DEVICES FOR TENANT IMPROVEMENT. 0 Z 10. FIRE SYSTEM WEST WILL BE INSTALLING ONE NEW FIRE ALARM NOTIFICATION DEVICE FOR TENANT IMPROVEMENT. 11. OFFICES 1 & 2 ARE ISSUED_FOR_R LESS THAN 120 SQFT. ci E,. BV �:aii % �/�°`� E I a x31 ..�// E r'�e S j TOTAL P , , . ,�`� _,✓,, � F /l f✓ •.� ... /^,h aw'�wvanu (�. .E„z„"� �,: ,&?.•. 'E / ►"Y.b �" 'T j'. ,// qs� • ''✓'' ;� E E -'.j F�^ 5, s f EE I , O O O O O O C Cf E'.+WbPaMYdA4b'a.'A4M' �� .s' I .d .a . t .,�� il/i�I �-., .,.... ".,.... .... ...._.6 �. q�yn m's,:,.,ws?� , 9A.iWa'FaGnWltap✓p'.. ��.. _ _ tlpppY�lN'd� VAIVAIIPPAIPAIVA �,{. licerArdir:Arir FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER x, WHITE WHITE WHITE WHITE WHITE WHITE WHITE i ' ZCT h_ SITE CONTACT: a D ESIGNISUPPLIER: I 77 KEURIG EXPANSION FIRE SYSTEMS WEST,INC. to 11 2'-0v ii ,• � it 7100 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C ” A w P w ”' TUKWILA, WA 98168 PACIFIC, WASHINGTON 98047, m a. ii' a- 11) r� 2 Ir .� �� PHONE: PHONE: (253) 833.1248 0 1... ) FAX: FAX: (253) 735.0113 �"� ,�' E Q,; ,--►" �"'7 �F WA 5T LICENSE: FIRESWI140B1 WA ST LICENSE FIRESWI055LW e : r © - IFIrdirettlirAler111,1 _—DESIGNER - '--'- -- z z„: ' --OFF►CE-1- of W W W W JJJJmmm / a4� 30CD m;tlrnto� OFFICE 2 •• MATT C ARLMAN ,,_ wwww/ I. � ,_J(�FIRE SYSTEMS WEST, INC ” I y rtn Ii �, A'IP �. ,,,� JIP ,, 206 FRONTAGE ROAD NORTH, STE C � � � �, � � � � _E, 1� b _." .... / PACIFIC, WASHINGTON 98047 :OUNT X PHONE (253) 833-1248 Fire Alarm Designer w m (253) 735.0113 Bryan Hilfiker �I\�,I _ I _FAX: IINICET 1 III 99�m 7,g:1.0= _►- o � ix :0) / , / / r' '-•-'..� ~,� ,... 15CD �AlOP �( Br.Vansl9rrMbyBryanHIlllker�.A�E�IrynHIHlNer o.Flre Sritemt West. � Inc,Ou-SpoWneofflce, r anal. ,mUS TYPE CEILING HORN STI OUTDOOR WALL F WALL HORN STRO WALL STROBE PULL STATION [SMOKE SENSORS HEAT SENSORS �I DatC.1017.1736114745-08'00' 2017 225-08'00 H i If i ke r LIJ OFFICE 3 A . /' cn -...,___-........., I Al A11011 AO Affil ,„ I Rix m g0 Fr: O \! EXPANSION AREA NICET LEVEL 11 146053 . W KEURIG EXPANSION FIRE ALARM PLANA 1412FPLP B 1612 FPLP EX EXISTING LOCATION CT WITH: C. 3ALLINGER WAY N LE, WA 98155 WAP FOR NEW M � � "�: I " Ill ;;,; �.,�,. .. " � _:3 4 ' DEVICE) WP WEATHER PROOF 41/8 =18' 12 20 N' NEW DEVICE R RELOCATE SCALE: -STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 20'x20' 30 cd = 20'x20' 75 cd = 20'x20' 30 cd = 30X30' 75 cd = 30X30' 95 cd = 30'x30' 75 cd = 40'x40' 95 cd = 40'x40' 110 cd = 40540' 50'11 05 eel a , 110 eel a!MA' Y 115Mafi(Yy511' CO CP KEURIG EXPANSION FIRE ALARM PLAN CONTRACT NAME: CONTRA KEURIG EXPANSION DP IN 7100 FORT DENT WAY 19936 TUKWILA, WA 98168 SEATTI CONTACT: VASILY SHADRIN 206-361-2 urig Fire Alarm Plan.cad DATE:12126/17TIME:11:03:15 WORK AREA ; .. • r.. I^•: �zii J Fort DattitPtay:. 1-. �.y�yy yy ..-_... ..:... .. .... y ...,.. ':,"-;y'%t MariufaclUrers Mineral.:. vl' . Homewood ,,::.:' Homewood fpra ,:; ... .. ...... ,T'J -. ,-.. .. ^.. .:.'r, :,='.,....... `ii' `.... .....: `"' ... HMori 5eati e:Tocdm#s:, .... .. .. ........ .. r. ......:....: i: may, ...... . r FIRE ALARM SYSTEM OPERATIONAL MATRIX I1S'[i ithWo(ks Pd.eidiaa Volley Lab r ° ;rhea! Y ALARM TROUBLE SUPERVISORY MISCELLANEOUS I Croix r r O 4 O O VL 54i ♦ O �J Q •V Q J PC♦P� 49 5 F �, JQ5 ',}tt.BtAte3C�Ado. 4 ::.: ..:.....':: .. �. , h c air...Airport sd ,,•- _ ;:4:.. ; TUk>iid'Fafttil GQ J PG� J YP�i4J O & NO' ..k.‘...k0 PP V. Q J0 QEQ.0 .0 OOOQQv G4iG� CAUSE (P'P' - . c, Q- - GP J O O y REMARK Fin Cettfr: a SUBWAY ,RePtrtturts .. E ... 817-0434 12126/2017 Ca SMOKE tHEAT DETECTORS O 0 0 0 0 n MANUAL PULL STATION 0 0 0 0 0 O SYSTEM RESET 0 OA Q SIGNAL SILENCE ®0 AC POWER FAILURE CINIT/ ::: Y iP INITIATION QR SIGNALING CIRCUITS9'!011 TAMPER SWITCHES 0 0 0 SCALE: N.T.S. `WATERFLOW SWITCH ® O 0 O 0 J TU WILA FIFE 1/.20 -1 -)it 0 w W Q J 0 1:-: = x a n cn co 5- ---I GENERAL NOTES 1 SCOPE OF WORK EX DEMO DEVICE BACK TO EXISTING FACP'TOjjALIOW FOR NEW DEVICES OPEN WORK AREA ± 16'-0" X 60'-0" OFFICE tT6 X12'-6" 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT, OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY 'AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 15CD RECEPTION. ± 174r X1 9'-)3* COPYIFILE t.62SF HOL 4.7K i2 TE t 4'- X 9'41! 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL BE INSTALLING NEW NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. 10. FIRE SYSTEMS WEST WILL FIELD VERIFY NOTIFICATION DEVICE CANDELA SETTINGS AND ADJUST AS REQUIRED. FUSE NETWORKS FIRE ALARM PLAN FIRE ALARM SYSTEM INFORMATION INSTALLER/SUPPLIER SITE CONTACT: FUSE NETWORKS DESIGNISUPPLIER: FIRE SYSTEMS WEST, INC. 700 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C TUKWILLA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735.0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE. FIRESWI055LW aa12' SCALE: 1I8"=1'-0" DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833,1248 FAX: (253) 735.0113 Fire Alarm Symbol Legend SYMBOL DESCRIPTION PART NUMBER MODEL QUANTITY UL FM B 75CD HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING HSRC HSRC 2 S2652 Approved 015CD HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING HSRC HSRC 1 S2652 Approved •/o\ 15CD STROBE, EXCEDER 24V, M -C, RED, CEILING STRC STRC 2 S2652 Approved (0.1024V) EOL 4.7K EOL -4.7 EOL -4.7 1 148.0000mA 20.1476V I EOL IR, Q EOL 4.7K Circuit Calculations Panel: P1 Card: 01 Circuit:SIG1 CircuitName: SIG1 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 2.0000A Cable: 14/2 SOL JKT FPLR 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop 5495 Panel REMARKS 20.4V SMOKE/ HEAT DETECTORS 6 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 31'-0 61.0000mA 20.3048V (0,0952V) 7 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 38'-0 82.0000mA 20.2024V (0.1024V) 8 HSRC HORN/STROBE, EXCEDER 24V, M -C, RED, CEILING, 75CD 25'-0 148.0000mA 20.1476V (0.0548V) 9 HSRC HORN/STROBE, EXCEDER 24V, M -C; RED, CEILING, 75CD 44'-0 148.0000mA 20.0911V (0.0565V) 10 STRC STROBE, EXCEDER 24V, M -C, RED, CEILING, 15CD 27'-0 61.0000mA 20.081V (0.0101V) 165'-0 500.0000mA Total Current: 500.0000mA (Total VDrop Percertit:1.56%) Total Voltage Drop : 0.319V p Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City . standards. Acceptance is subject to errors and omissions which do not: authorize "iolations of adopted ,:. ndards and oroinaflces. The responsibility for the )dequacy of design .0 P'srs totally with the designer, Additions, deletioom ;'evisions to these drawings after :his date will void tr11v ,.cceptance and will require a t esubmittai c)i `•e;vi'r`r-` Drawings for subsequent approval. Final acceptance i subject to field test and Inspection by The Tukwila Fire Prevention! Bureau. Date: S--" I - I g _By: U VILA FIRE DEPARTMENT Please call 206-575-4107 anct give this Fire Permit No, 1 - r -o C rid exact Edda v.:as for shut jov4'n or restoration approval. NICET LEVEL 11146053 1412 FPLP 16/2 FPLP EXISTING LOCATION (SWAP FOR NEW DEVICE) WEATHER PROOF NEW DEVICE RELOCATE •STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. • 30 FT. CLG. HT. 15 cd = 20'x20' 30 cd = 20'x20' 75 cd = 20)(20' 30 cd = 30'x30'. 75 cd = 30'x30' 95 cd = 30)(30' 75 cd = 40'x40' 95 cd = 40'x40' 110 cd = 40'x40' 95 cd = 50'x50' 110 cd = 50'x50' 115 cd = 50'x50' r FIRE ALARM SYSTEM OPERATIONAL MATRIX ALARM TROUBLE SUPERVISORY MISCELLANEOUS 1 CAUSE A. �v4 p� v� v� JGg14(' Q`si , ���S�� �ci4%4 Qi�ppp" p��* 4�C949 014.01 R O O REMARKS SMOKE/ HEAT DETECTORS 0 0 0 0 0 MANUAL PULL STATION 0 0 0 0 0 SYSTEM RESET 0 SIGNAL SILENCE 0 0 AC POWER FAILURE 0 0 0 FIRE ALARM TROUBLE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS 0 0 0 TAMPER SWITCHES 0 0 0 `WATERFLOW SWITCH 0 0 0 0 0 J TL1k91,1 srTaily° Fun Cealters&,,; VICINITY MAP PAID •-_ 1 �n1 SCALE: N.T.S. TUKWIL.AFIRE C .2-ov 21=1142212) €11112 011211111=112213 COD CZE1111=1111210 CM) CESE4211111=41112 C3=1211111291:212 =2 CID CC '*ATE lir Without Comments Q As Noted In Red O Per The Attached Letter se plans have been reviewed by The Tukwila Fire •?ention Bureau for conformance with current City dards. Acceptance is subject to errors and sslons which do not authorize violations of adopted dards and ordinances. The responsibility.for the quacy of design rests totally with the designer. itions, deletions or revisions to these drawings after alb CUD C=116111 11121116 411111=111=21 OPEN OFFICE l ■ ■ OPEN OFFICE PRIVITE OFFICE INTERCEPT EXISTING - CIRCUIT resubmittal of revised drawings for subsequent appr val. :=ina1 acceptance is subject to'neld test and inspectiot by The Tukwila Fire Prevention Bureau. vete: II' 1 �- I By: / 141^► J' I ■ • ■ i 0 1 0 1 PRIVITE OFFICE CONFERENCE IN1 CIF ELEVATOR LOWY ■ ■ ■ SERVER OPEN TO BELOW INTERCEPT EXISTING CIRCUIT 1 1 a 1 0 1 II 11 11 11 11 II 11 11 II 11 11 Id RECEPTION 1 FIRE ALARM PLAN SCALE: 1 / 16" = 1' - _ NOTICE 1 SECOND FLOOR PLAN A completed,. signed, Tukwifa° 5 'a 107'1'a Fre .Department Pre-test �" Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a_Re-inspection Fee and termination of the testing NORTH Froula Alarm Systems, Inc. 861 Industry Drive Tukwila, WA 98188 206-575-1962 i 1 CONFERENCE 30 c BREAK INTERCEPT EXISTING CIRCUIT Equipment Legend Symbol Quantity Part Number Description Back Box 0 — Fire Alarm Control Panel Included .1-1pp 0 — Fire Alarm Power Supply y Included 0 — Remote Annunciator Included RA O0 - Photoelectric Smoke Detector 4" Square O0 - Heat Detector 4" Square 0 — Manual Pull Station 4" Square F X1 2 HSR Wall Mount Hom Strobe 4" Square 2 STR Wall Mount Strobe 4" Square OIJ g1 HSCR Ceiling Mount Hom Strobe 4" Square 0 0 — Ceiling Mount Strobe 4" Square DD 0 BY OTHERS Duct Detector INCLUDED 0 BY OTHER Water Flow Switch 4" Square ® BY OTHERS Tamper Switch 4" Square ft0 WIRE LEGEND A- 18 GAUGE 2 CONDUCTOR 'FPLP' B- 14 GAUGE 2 CONDUCTOR 'FPLP' C- 18 GAUGE 4 CONDUCTOR 'FPLP' D- 14 GAUGE 4 CONDUCTOR'FPLP' NOTES: 1) ALL WORK TO CONFORM TO NFPA 72 AND NEC STANDARDS 2) WALL MOUNT HORN STROBES AND STROBES TO BE MOUNTED 80"-96" AFF OR 6" BELOW CEILING WHICHEVER IS LOWER. 3) PULL STATIONS TO BE MOUNTED: A) 48" - 53" AFF B) WITHIN 5' OF THE DOOR. 4) FIRE ALARM CONTROL PANEL TO BE ON DEDICATED CIRCUIT 5) WIRING METHOD TO BE OPEN CABLE UNLESS BELOW 7' AND EXPOSED, THEN IT WILL BE CONTAINED WITHIN CONDUIT. 6) SMOKE DETECTORS TO BE INSTALLED: A) MORE THAN 36" FROM ANY HVAC DIFFUSER B) NOT IN CLOSE PROXIMITY TO FLUORESCENT LIGHTING C) AT LEAST 6" DOWN FROM PEAK IN SLOPED CEILING 7) ALL JUNCTION BOXES, MUD RINGS AND BOX COVERS TO BE PAINTED RED (INSIDE AND OUT). 8) EXTERIOR HORN STROBES TO BE MOUNTED IN THE TOP 2/3 OF THE BUILDING STRUCTURE FACING THE ANTICIPATED FIRE DEPARTMENT ACCESS ROAD. 9) ALL DEVICES ARE EXISTING RELOCATED. NO ADDITIONAL DEVICES TO BE INSTALLED SO THE BATTERY CALCULATIONS WILL NOT CHANGE. PAID FIRE ALARM PLAN (Th LEGENDS SCALE: NONE. SCALE: 1 / 4" = 11- 0" 1--"A� NOTES SCALE: NONE FEB u 6 2014 ..`UK'vBILAFIRE cc PO DESIGNER OF RECORD Kristopher Conner NICET IV 69311 `ti LA FIRE DEPARTMENT can 206.575-4407 and Ay this Fire Permit No. 1 eta;. address for shut- down restoration approval. wo 0(0 CD N 0 rivN = >a: ao rn OWE zoQ OE- oo Z 10E- (1)0 5 DATES SUBMITTAL: FEB 3, 2014 REVISION: SHEET TITLE FIRE ALARM PLAN SHEET NUMBER FA -1 A CE 1' As Noted in Red Tp Per The Attached Letter se plans have been reviewed by The Tukwila Fire 'ention Bureau tor conformance with current City -dards. Acceptan:.e is subject to errors and ssians which clo : <r..t c,utharite violations of adopted -dards and ordinanc;:„s. The responsibility for the quacy of design res"s toiz;iy with the desfgncr. -tions, deletions c . revidous to these drawings after date will void this ;c,.:ept oce and will require a ubmittal of revised drawings for subsequent approval al acceptance is s .l%::tec t to field test and inspection b Tukwila Fire. TUKWILA FIRE DEPARTMENT Please call 206-57541V aild give this Eire Permit s No. and exact add: ess for shut- down or restua .ion approval. EXISTING SMOKE DETECTOR CIRCUIT ELEVATOR LOBBY FIRE ALARM PLAN - SUITE 210 } SCALE: 1 /8"= 1'-0" E-21 BUILDING PLAN SCALE: 1 / 16” = 1' - 0" Equipment Legend Symbol Quantity Part Number Description Back Box 1 D9412 Fire Alarm Control Panel Included 1 10i; _� 1 5495 Fire Alarm Power Supply Included O3 SD355 Existing Photoelectric Smoke Detector 4" Square 1 HSR Wall Mount Hom Strobe 4" Square 1 STR Wall Mount Strobe 4" Square ID T29 PC2R Ceiling Mount Hom Strobe 4" Square 0 38 SCR Ceiling Mount Strobe 4" Square NOTES: —\AAr-)2( )2( )2( )2( )2( 1) ALL WORK TO CONFORM TO NFPA 72 AND NEC STANDARDS 111 JEN`1` KN I(.: 11'1. NW Healthcare Kristopher Conner 2) WALL MOUNT HORN STROBES AND STROBES TO BE MOUNTED 80"-96" AFF OR 6"BELOW CEILING WHICHEVER IS LOWER. 495 Power Expander Calcu(a Version 02 18.09 11/22/2013 WIRE LEGEND A- 18 GAUGE 2 CONDUCTOR 'FPLP' B- 14 GAUGE 2 CONDUCTOR 'FPLP' C- 18 GAUGE 4 CONDUCTOR 'FPLP' D- 14 GAUGE 4 CONDUCTOR 'FPLP' 3) PULL STATIONS TO BE MOUNTED: A) 48" - 53" AFF B) WITHIN 5' OF THE DOOR. )2( )2( )2( 4) FIRE ALARM CONTROL PANEL TO BE ON DEDICATED CIRCUIT 5) WIRING METHOD TO BE OPEN CABLE UNLESS BELOW 7' AND EXPOSED, THEN IT WILL BE CONTAINED WITHIN CONDUIT. 5495 Pwr Module 5495 Circuit 1 cfg. 5495 Circuit 2 ctg• 5495 Circuit 3 5495 Circuit 4 #14 Solid #12 Sohd #12 Solid 0.060 #12 Solid #.12 Solid 6) SMOKE DETECTORS TO BE INSTALLED: A) MORE THAN 36" FROM ANY HVAC DIFFUSER B) NOT IN CLOSE PROXIMITY TO FLUORESCENT LIGHTING C) AT LEAST 6" DOWN FROM PEAK IN SLOPED CEILING 7) ALL JUNCTION BOXES, MUD RINGS AND BOX COVERS TO BE PAINTED RED (INSIDE AND OUT). 3.72% 0.00% 0.00% 0.00% 0.00% Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the ninin-al difference between sold and stranded wire no differential was trade. IPS TO ADJASCENT POWER SUPPLY FOR TRIGGER TO UNSWITCHED 1 2 DEDICATED 120VAC POWER 2 system senior P2/PC2Horn/Slrobe (754 System Sensor P2/PC2 Hom/Strabe (3Q4 8) EXTERIOR HORN STROBES TO BE MOUNTED IN THE TOP 2/3 OF THE BUILDING STRUCTURE FACING THE ANTICIPATED FIRE DEPARTMENT ACCESS ROAD. t'Pah nn 1 Dnuuer -C, mnhr i'nnM '1.1 Totals `=,O. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will resp.}4r in a Re -inspection Fee termination of LEGENDS SCALE: NTS 4 NOTES J SCALE:NTS RISER DIAGRAM SCALE: NTS BATTERY CALCULATIONS SCALE: NTS .2 PAID MP'/ 2.,t ?p1:1 P � °v1L i „.1 F -2- f 37 Froula Alarm Systems, Inc. 861 Industry Drive Tukwila, WA 98188 206-575-1962 DESIGNER OF RECORD Kristopher Conner NICET IV 69311 0 Nr— N !is)U 00 .0 o0 �coCD Q c a) a)co � 0 § -0t o �� Z � 0 0 ti DATES SUBMITTAL: REVISION: SHEET TITLE FIRE ALARM PLAN SHEET NUMBER FA -1 LS1:7\T IJCiI!IC INC. 7100 FORT DENT WAY TUKWILA, WA 98168 Device Legend FACP FAA PS P IRI T JP ISI FP WP VS WF GV HSC LF Fire Alarm Control Panel Fire Alarm Annunciator Power Supply Smoke Detector Pull Station Relay Module Tamper Switch Jockey Pump Controller Wall Mount Strobe Ceiling Mount Strobe Wall Mount Hom Strobe Ceiling Mount Hom Strobe Low-Freq. Wall Mount Horn Strobe Mini Horn Fire Pump Controller Weather Proof Sprinkler Valve Supervisory Switch Sprinkler Flow Switch OS&Y Gate Valve Wall Mounted Smoke Detector Non Addressable Heat Detector Fire Fighter Phone Hand Set Center Low Frequency Sounder Wiring Legend A B C D E Denotes Ckt. Number 14 Gauge 2 Conductor FPLP 18 Gauge 2 Conductor FPLP 18 Gauge 4 Conductor FPLP 17 Gauge 2 Conductor FPLP Category 5E Cable Typical Mounting Height FACP FAA P S EK PS Q EK WP 60" To AFF 60" To ¢ AFF 46" To ¢ AFF 48" To ¢ AFF 80" To AFF 80" To ¢ AFF 60" To ¢ AFF 4"-12"(MAX) To t From Ceiling 8'-101(MAX) To ¢ From Floor Notes 1. 2. 3. 4. FA1 COVER PAGE --------)11111111111111111111 BEVERAGE BAR AREA 202 TO P.S 1A 3 mTrfTTTTT 1 n 1 r[ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 FIRE ALARM RISER LEVEL 1 P.S P.S CKT 1A 7 INI 30 E.O.L L11111111I 1 RECEPTION 201 7 / / / / / / / 1111111 III IIIIIIIIIIIIIIlI 1111111 111111111111111111 I FEC WORK AREA 230 85 / / / / / / / / 11111111111111111111111 116 /S^ ACCOUNTING 222 ♦15 / / / ACCOUNTING 221 / / / / / / / / / / / / / OftmmioNftwowg DN. STAIRS 15 / / / / / / / / / / FEC CORRIDOR 220 30 KITCHEN BREAK E.O.L 219 P.S 1A 1111111111 1111111111111111 v/ / / / / / / / / / / / / / / / / / / / / / / /lo _11111111111111111111111111111111111 II 111111111111111 11111111111111111111 31 111111111111111111111111111111111 FIR 3/16"=i'0" ALAR V LA`/OT p Without Comments As Noted in Red rp Per The Attached Letter These plans have: been reviewed by The Tukwila Fire Prevention Burerl.,. >1' :onformance with current City standards. Acceo :- , r. Subject to errors and omissions which tj : , i..,thorize violations of adopted standards and The responsibility for the adequacy of desit r:,,otally with the designer. Additions, deletions .::.visions to these drawings after this date will voi6 r, :- :ebtance and will require a resubmittal of = vi :'t' E: °- ,,,vir25 for subsequent approval. Final acceptance i :° I, , t field test and inspection by The Tukwila Hie P evenrrorl Bureau. Date: 1-13 -/ 7 By:_, t � E r,sv� 1414,1/4.41 r at I s kin," a,4 elc4 $ t) . TUKWILA FIRE DEPARTMENT Klan call 206-575-4407 and give this Fire Permit No. and exact ad i ss for shut- down or restoration approval. PAID ►.wig WKWILA FlPtc 00 O 4-4 0 Revisions: aQ o 0 _ ❑ u. m a) ❑ r, 1/9/2017 Drawn By: RS eeSli t�umirer :. FA1 Fire Alarm Symbol Legend SYMBOL DESCRIPTION PART NUMBER MODEL QUANTITY USER TEXT UL FM 1:0:( RADIONICS 2 -WIRE, HORN STROBE, RED, WALL D570S D570S 10 EX SMOKE I HEAT DETECTORS 0 RADIONICS 2 -WIRE, HORN STROBE, RED, WALL D570S D570S 2 0 ;0; ft ® Without Comments As Noted in Red ® Per The Ai.achedi Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau f'nr conformance. +:t. il:h current City ndards. Accepri:'•rl:..: S' subject roi 9!IR,`'i.?1-1d 1 nissIonS'vhIC1': rl'1 :''fa; :;1.19"horIze viol-4ions 1::1 adopted -,a, (:lards and arc*, ,,.c ::. The resuonsibiiity for the :cie,,quacy of de sic. totally with the designer, Additions, deIerfons %Isions to these drawings after i:Ns ,iFte 11., •icceptance and will require a resubn?I; . .. vii!ngs for.. subsequent approval. Final acceptance is subject to field test and inspection by Tne Tukwila Fire Prevention Bureau. Date: 11- 8-1 By: kr"- rt T . s'71It-A FIRE' DEPARTN NT r-. ;I 20.5-5M-140 and give this Fie Permit N®. and exact address for shut- down or restoration approval. WOOD-RICHARDSON & CO. INN Ell pp B k SCALE: 1/8" =1'- 40" 12' 20' FIRE ALARM DEMO PLAN ' FIRE ALARM SYSTEM OPERATIONAL MATRIX DESIGNISUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY , SUITE 225 ALARM TROUBLE SUPERVISORY MISCELLANEOUS I CAUSE 41. co y��Q� ��P�Pa�o�S O0v JPO �cP ..cd-" Jp\0N'0 GQ sl, 4. is is Ns �6 0 e*PSP �P'� v- Zo J1t.1, 4�,��s4'• c, C.. 4' 4 N, Y.0' r N- io ,r,Q�4°4° 4 4 4s1 eo0',.-0 WA ST LICENSE: FIRESWI055LW REMARKS SMOKE I HEAT DETECTORS 0 0 0 0 0 MANUAL PULL STATION 0 0 0 0 0 SYSTEM RESET 0 SIGNAL SILENCE 0 0 AC POWER FAILURE 0 0 0 FIRE ALARM TROUBLE (OPEN, SHORTS, OR GROUNDS) ON INITIATION OR SIGNALING CIRCUITS 0 0 0 TAMPER SWITCHES 0 0 0 WATERFLOW SWITCH 0 0 0 0 0 WOOD-RICHARDSON & CO. 1111111 1 .,,..,r111111,, �1■ pB 4 SCALE� 118=1$30" 12' 20' FIRE ALARM PLAN GENERAL NOTES 1 SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSULATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F•P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING (T -TAPPING) OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE WILL IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST WILL RELOCATING EXISTING FIRE ALARM NOTIFICATION DEVICES FOR TENANT IMPROVEMENT. 10. Verify voltage drops and calculations in field before final test. Provide results to AHJ. FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER SITE CONTACT: WOOD-RICHARDSON & CO. DESIGNISUPPLIER: FIRE SYSTEMS WEST, INC. 7100 FORT DENT WAY 206 FRONTAGE ROAD NORTH, STE C SUITE 225 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735-0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE: FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE C PACIFIC, WASHINGTON 98047 PHONE: (253) 833.1248 FAX: (253) 735-0113 X FOR FIRE DEPARTMENT USE ONLY Fire Alarm Designer Bryan Hilfiker SET NICET III 99709 Bryan Hilfiker A B EX WP N R 14/2 FPLP 1612 FPLP EXISTING LOCATION (SWAP FOR NEW DEVICE) WEATHER PROOF NEW DEVICE RELOCATE •STROBE COVERAGE AREA SHALL BE DEFINED AS: 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 20x20' 30 cd =20'x20' 75 cd = 20'x20' 30 cd ■ 30x30' 75 cd m 30'x30' 95 cd ■ 30x30' 75 cd - 40'x40' 95 cd m 40'x40 110 cd = 40x40' 95 cd = 50x50' 110 cd = 50'x50' 115 cd = 50)(50' WORK AREA t Digitally signed by Bryan Honker DN:cn.Bryan -Fire Systems ;Wert, Inc...Spokanetxlke, emaB.BryanHmHresystemsWest.com, Da t e: 2017.11.01 13:4240 -0708' Lance Tarim nufncture€n.ldin; Fiomavuood Suiies' tiilion.SeaiiI Tacoma; ertia ?all GUy R.,V $ BaauSiora Tukwila Family 'Fun Cunler 4 .' UBW t `vR gill VICINITY MAP PAID SCALE: N.T.S. NT/ 03 2011 TUKWILA FIRE Fax: (253) 735-0113 00 M C+ ) c0 LC) WA CO FIRESWI 140B1 0 z 0 0) ce ISSUED_FOR_REVIEW 0 z EW DEVICE COUNT J 0 z c 0 r) w I— x w 1- x w 1- w I~ w w rr- w 1- 2 w 1- J w 0 N 0 0 ce CL MS -7 SERIES LL a ILL SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR SYSTEM SENSOR GAMEWELL FCI GAMEWELL FCI GAMEWELL FCI GAMEWELL FCI CEILING HORN STROBE OUTDOOR WALL HORN STROBE WALL HORN STROBE WALL STROBE PULL STATION SMOKE SENSORS HEAT SENSORS ce 0 z e WOOD-RICHARDSON & CO. FIRE ALARM PLAN W z LU co • Z U Urn—I ?C) a� `r 0 0r'CO rn 00 C C co ceiV Z v) >- -J (J) 0 0 w 1- 0 RD O rs- 00 1-'- W 0 a. FILE:Wood-Richardson & Co. Fire Alarm Plans.cad DATE:10/31/17 TIME:15:59:13 — • LEND 0 101 EXISTING WALL TO REMAIN NEN OFFICE PARTITION WALL PER DETAIL I/A2 EXISTING FURS OUT OF EXISTING COVE WALL PANELS BUILDING STRUCTURAL COLUMN BUILDING,. GRIDLINE DOOR NUMBER (REFER,ENCE DOOR SCHEDULE) RELITE NUMBER (REFERENCE RELIT E SOHEDULE) ROOM NUMBER (REFERENCE ROOM SCHEDULE) ELEVATION DESIGNATION CEILING, GRID EXISTING 2X4 (5) TUBE RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN 2X4 (3) TUBE RECESSED FLUORESCENT LIGHT FIXTURE EXISTING GNI5 CEILING •<:)- EXISTING CAN LIGHT FIXTURE TO REMAIN DETAIL DESIGNATION NEN EXIT SIGN LOCATION KEYNOTE DESIGNATION DUPLEX OUTLET FOURPLEX OUTLET POWER SUPPLY FOR SYSTEM FURNITURE DATA LINE SUPPLY FOR SYSTEM FURNITURE KEYNOTES I. REFER TO DETAIL 5/A2 FOR IMPORTANT DETAILS OF PONER/DATA PHONE RUNS BELOW WINDOW SILLS. 2. VERTICAL BLINDS (SEE RELITE/FINISH SCHEDULE). • PERIMETER WALLS HAVE /MEN FURRED' AND INSULATED (RI5) UNDER THE BUILDINEYS SHELL PERMIT. 6YP. BD. HAS SEEN TEMPORARILY PLACED (NO TAPING) FOR REMOVAL DURING POWERING UP OF TENANT SPACE. REINSTALLATION, FURS OUT DETAIL SHOWN IN 5/A2, TAPING AND PAINTING ARE A PART OF THE SCOPE OF WORK UNDER THIS CONTRACT. • 1 11 I - I 11 1 L L \.••• STAIR P2 121 -of " 10 -0' '-O" ,1 0 ADJACENT LA!AREA 10I -Oft 5'-0" • VERIFY - -40••••••••••••••••••14-. STOR. ILDINS '51-2" 0 OPEN OFFICE 206 „ cokFERENce 202 0 1445-11 ri 71-4" 4'-t t1 MIN.. CZI MA T. R1.! 25'-0" 25'-0" 25'-0" FLOOR FLAN co 21•11, FLOOR SCALE: I/8" = . , • ... • " •-•-•: , • _ s!; • "•*;,' -•. TA1R •-• Jo • C=NT E1AREAi- • • • - • • ; =0.1NOMMI ! • . sa Al 111, 206 ; • • :re R FLECTEDCLG. FLA SCALE: 1/8'= I'0 Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and Will require a resubmittal of revised drawings forsubsequent approval. Final acceptance is subject to field test and ins cti • S4.A.t. chtti TUKWILA FIRE DEPARTMEN1 Please call: 575-4407 and give this job No. q‘q r•-/76 and exact address for shuti down or restoration approval. •-4-1*PlYinell fie-rei dm, Bureau: -1,00R SCHEDULE - Date: / By: 5(-.1./ 1700R * POOR SIM DOOR TYPE FRAME HRS GROW . . J.!FINISH - : - REMARKS ' . .........a. • EXISTING TO REMAIN , . -- • ' - SEE. COLOR SAMPLE 4/15/cf4i - . .. EXISTING . • 01 5'-O" X 81-0" X 1 5/4" ' SOLID CORE 104001, DOOR/MAPLE VENEER NOOD FRAME A SEE COLOR SAMPLE 4/15/4101 .. . , 02 31Q1 X 610" X 1 5/4" SOLD CORE loslOOD DOOR/MAPLE VENEER ' KOOD FRAME ' A . sEE COLOR SAMPLE '4/15/41c1 05 5'-O" x a* -o" x 1 5/4" ! SOLID CORE IAIOOD DOOR/MAPLE VENEER- • HOOD FRAME A -- .. EE COLOR A LE 4/15/c141 DOOR LOCKED . 04 5'-0" X 8'-0" X I 5/4" SOLID CORE V4002-00R/MAPLE VENEER NOOD FRAM!. . A . . EE! COLOR SAMPLE 4/15/0141 ! 05 5-0" X 6'-0" X I 5/4" -SOLID CORE WOOD POO APL VENEER WOO. FRAME A - SEE COLOR-AMLE 4/15 4141 . - DOOR LOCKED 06 5-0" X 6'-0" X I 5/4" SOLID CORE 1•4001, DOOR/MAPLE VENEER - . . HOOD FRAME . A SEE COLOR SAMPLE '4/15/4441 . DOOR LocKED . . . . • .. , . I TE'i'SCHEULE . .. RELITE * RELIT! SIZE .. . . . 01 ' 45.-o"XFULL 1-4T.(l'-0") THROATED 1^100D .. SAFETY.•GLAS •VETICAL BLINDVI5.71 , 02 .61-0"XFULL HT.(11-09- THROATED NOOP. SAFETY GLASS FIELD VERIFY I RTICAL SLIM'S V5-1 05 I'-0"XFULL HT.(71-0") THROATED 1A1000 - SAFETY -GL AS .. . . . ,,.. . . . . . . ,. • . . • • . . . ROOM FINISH 5 -4 U E CEILING . . . . .. . . • . F1..00R .... . ., REMARKS , ROOM NAME FINISH HEIGHT , FIN SH. .• SASE. NORTHNEST * ..SOUHNEST SOUTHEAST NORTI-EAST ' 201 ENTRY' ACOUSTICAL Cl...e. GRID '-6"! CARPET/C1 , RUBSER/Rf3-1 . HS/PAINT/DOOR P -I. 61,43/PA T P -I. - GNE3/PAINT ..P-1 , Gk/PAINT P -I 202 CONFERENCE ' ACOUSTICAL CL.G. GRID 6-6" CARPET/C;7:1 . . . SUEOEFt/133;-1 - ' 6H5/PAINT . P -I 6HE3/PAINTAN INDON P -I GH15/PAINT PLI 61,45/PAINT P-1 205 COPY' ROOM , ACOUSTICAL CLG. GRID , 61-6" - VCT -2. , RUE3SER/Rfir3 - .- 645/PAINT -P-1 '. SKS/PAINT/DOOR P -I , 61'45/PAINT P -I GINEWPAINT P-1 204 . OFFICE • ACOUSTICAL CL6. GRID 81-6" , • • -RtABBER/R13-1 :, -• GKE3/PAINT P -I . eke/PAINT/WINDOW P -I 6K5/PA1NT P -I G /PAINT P-1' 205 KITCHEN ACOUSTICAL C.L.GRID ' ,CARPET/C-1 &'-b" - VCT -2- „ . . . RUISBER/R13"3 , - .N5/PAINT P-1 ! 6Y45/PAINT/D00R P -I - Gi"45/AINT P -I . Glee/PAINT P -I . 206 STORAGE ROOM ACOUSTICAL CLG. GRID 't" ' VCT2 . - . . • RUBERigS 3. ---611%15/PAINT P-.1 6HE3/PAINT/0OR PI 6HE3/7:1,,,,INT. P1 G5/FAINT P1 207 . PBX AC0UT1CAL.'0LG. GRID' . . '-6" •,- . VC:1-2 - RUBER/R.8 -3 - . '614/PAINT/0C* P -I r 61"0/AINT P -I : HEs /AINT P -I - GIAl5/PAINT P -I 208 OPEN OFFICE ACOUSTICAL -CLG. GRID . .5'6" - 61.113/PAINT/00R P I._ GIAIEVPAINT/1/41N1,01,41 P-1 61,41E3/PAINT - P -I •. , GIAIB/PAINT P -I CARPET/C-d - - . 20c1 • EXISTING BLDG. COMMON CORRIDOR • , _ EXISTING 1 HOUR CORRIDOR . 7- - • .. - . . ' • , .. . -,,,, • • 1 , . . .. , . . . . . HRDIAIR SCHEDULE . . , - -i-- :FINISH r . ' SCHEULE -. . • .. HARDKARE A . 3'-orx8o-o.xl 5/4" SOLID CORE 1"100'D DOOR 2 PAIR BUTTS 4 1/2 X 4 1/2 I LEVER.PASSAESET 1 NALL.STOP .. 5 SILENCERS . .. G -I , CARPET COLLINS AND ALKMAN ' "LUM1NARIE" . . COLOR: ' GRAPHITE 41205 1"1/RS BACKING 6'INIE BROALOOM, .DIRECT 61, -..UE DOWN - LOS ANGLESlEP.: , MS.. ANNE PROOKES • (800). 241-4402 EXT. 1666 • r114) 663666 NOTE: HYUNDAI 1'4ILL PROVIDE CARPET C -I LP -I• - . .. ' PLASTIC LAMINATE NEVAMAR COLOR: FDLATINUM GRAY PS -5-25T . . . .. '...- 1::.,I'! , ..PAINT -.----- ' DUNN E.DARDS.. • . -. .COLOR: 106 DAs1N EGGSHELL OR TOMATCH . ' ' . - . . RS7S . '• • ' , , , RUBBER -BASE ..BURKE ,.COLOR: - PLATINUM PI45P ' '• 4" HIGH OVED-15ASE AT VCT ' VCT -2 ARMSTRONG - "STEP MASTER, SLIP-RETARt7ANT TILE" - COI -OR: 'SLATE P5072 12°X12'X147V GAUGE LOS AN6ELEs- REP-.: M5, LAURA HUBBARD (800). 55675G01 'EXT.- 541c15 . - 1.17-; , : . , . . . _. PLASTIC LAMINATE '-• HILSONART • - - • . •- COLOR: .BLUE NEBULA *46266' - .... • . - ' . . .Rip - -1 -- . . .- • . --RUSSR SAE. • . • BURKE --- -• • • .. - - . - COLOR: STERLING *665P - ' 4" HIGH !STRAIGHT BASE AT CARPET , . ry40-1. . • ' fr4000. VENEER ' . PREMIUM GRAD; PLAIN. SLICED MAPLE, MEDIUM FIGURED ' . • STAIN i TO MATCH SAMPLE '- . • . . . . , , '." ' . . . :VE3-I -.. ' ' VERTICALlBLINDS • LORERAPE- • (TOBE VERIFIED IF REQUIRE) . ELITE: TRAcK, CEILING MOUNTED c..OLOR: ,.PERPORATF-D INHITE r • ' REP::- ' LOS ANGELES FILE MR. NILSANDERSON - ' - ' - (600'626-V19cl. .- EXT. 5Cr701 .... .... . . _ , .... . , ,..• - : - . ! P -I -• . PAINT ' UNN- EDIAtAPP-DS - COLOR: -106 DANN, EGGSHELL OR. TO MATCH -' . . .. , . LP -.5. - PLASTIC LAMINATE- , ,NEAMAR,! . COLOR= . St -JOKEY WHITE *ST1-21T.- : . . ... . • . . . . , . •' ' • ,. ••• . • •. , . .. , . ,". . - . . . . , . -:.FP.E3-2 . - r - RUSASEE - .BURKE-.• . ..COLOR:- aLt1-1.1,41-HITE *168P .: ' - . .. 4" Hicki COVED.!BASE AT VCT:.-..,- , : , -..• ,, •.. • . . - • • ,•- • • : ... .•, _ . • • • Ft.tihAtil DtSiGN GROUP PROJECT: HYUNDAI AMERICA SHIPPING AGENCY INC. Fort Dent III 7100 Fort Dent Way . ' Tukwila, Washington .98188 SHEET INFORMATION: FLOOR PLAN; REFLECTED CEILING PLAN; LEGEND; KEYNOTES; SCHEDULES JOHN C. RADIVICH DEVELOPMENT 2000 124th Avenue N.E. Suite #B-103 Bellevue, Washington 98005 • HYUNDAI WASHINGTON • c/o Landmark Management 879 West 190th St., Ste 400 Gardena, CA 90248 • REVISIONS: • C:\IF:GDWG\95\96135.16\813516A14wg • • OxRELELF(: TlIEFwRIFMERRAinirrENANy 041);E:RSIriGNIsiExcepTC:UrRotAP. 1004: iAN: • -„ ALLFERRARRIG1 CGOWC0RAinswINGslserE\ARsiptseci:01.E.p113:ppRollr3E5T1996Xii.89.Fdw cr AR- NOT .70' 13E USED OR REPRODUCED - . • ; ,•• JUN 0 31999:: go! cfeckedBy: FH Drawn By. PSCOTT Date: • • : April 28,1999 Sheet No.: , 1 CONSTRUCTION DRAWINGS- TRAININ e STOR 20 WALK— CL. 2t9 11 OPEN OFFICE 205 ///,/////////////,/,// / / / / / / / / / / FFICE 204 / / / / / / / / / / / ////,//, //,////l 0 ICE 03 ADJACENT TENANT TO FACP/POWER SUPPLY RECEPTION 206 207 STAIR 202 BUILDING COMMON CORRIDOR VOCATIONAL ROOM 211 CLASSROOM / / / / KITCHEN/ 210 / 201 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / I/ / / / / / / / / / / ADJACENT TENANT 25'-0" 25'-0" 50'-0" LEGEND x STROBE ONLY RADIONICS D506S/I5CD HORN/STROBE RADIONICS D574/75CD POWER SUPPLY: SILENT KNIGHT MODEL #: SK5395, 6 AMP. NOTE: THIS POWER SUPPLY IS FOR THE CLINIQUE T.I. & ANY FUTURE OR ADDITIONAL 2ND FLOOR T.I. CCS ❑,, Without Comments As Noted In Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings forsubsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date:_kp I . i9. By: 45.- r TUKWILA FIRE UEPArti'�vi�IVi Please call: 575.4407 and give this job 03 and exact address for stnit. down or restoration afiorQV4i, r FILE CLINIQUE SERVICES INC. FORT DENT III 7100 FORT DENT WAY TUKWILA, WA. 98188 DESIGNER: JIM O'DONNELL GERRY VUCCI DRAFTING: TRAVIS MCCLURE EaULIEITT WA. LICENSE #044QF DATE: JUNE 7, 1999 SIZE D REV NEW AUDIO/VISUAL FIRE SCHEMATICS SCALE NONE SHEET 1 OF 1 N IT JUN 21 ;qqq 140'-0" 20'-0" 25'-0" 1 25'-0" i 25'-0" c5'-0" TO FACP ZONE 4 immk/AL Aka ai 4 NEW 12' HIGH GYP, BD. SOFFIT TO FACP ZONE 3 DLAN BREAK: ZONE CONTINUATION TO UNIVERSITY OF PHEONIX FOR POWER REQUIREMENTS. CU 0 CD En L N,'G hND HORN/STROBE: RADIONICS D572S 110 C.D. MINI HORN/STROBE: RADIONICS D559S 15/75 C.D. POWER SUPPLY: SILENT KNIGHT MODEL #: SK5395, 8 AMP. NOTE: ALL DEVICES NOT ACCOUNTED FOR IN RUN FEEDS "I" THRU "4" ARE EXISTING, AND WERE INSTALLED IN ORIGINAL PERMIT DATED 03/08/99 # 99F06A, FINALIZED 04/15/99. CCE TE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for.subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /. By: TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job No.��" and exact address for shut= down or restoration approval. r IIL liMMEWM Ai JUL iq 1999 00•41114011*•1116 epe* PAB THEARAPUTIC ASSOCIATES FORT DENT III 7100 FORT DENT WAY TUKWILA, WA. 98188 DESIGNER: JIM O'DONNELL GERRY VUCCI DRAFTING: TRAVIS MCCLURE DATE: JULY 14 1999 gT1131M1 Aggin[rITV WA. LICENSE #044QF SIZE D REV NEW AUDIO/VISUAL FIRE SCHEMA TICS ISCALE NONE SHEET 1 OF I 0 0 SENTEX PHONE_ RADIONICS READER NEED 2 8004'S & ONE DUPLEX OUTLET. SANYO 'REAL TIME" VCR SMV 16 MUX 12' MONITOR CO' FUTURES FOR TENANT ALARM DATA. BELL CIRCUITS, & KEYPADS. 1T1 6 x 02. SUPRA BOX WITH TAMBER SWITCH s IIIMMIION01•1•16 11.1.O111=1101 BS HS LEGEND 30 CD STROBE ONLY OUTDOOR BELL -STROBE 110 CD HORN STROBE RADIONICS 9412 FIRE PANEL SPRINKLER RISER FLOW VALVE POST INDICATOR VALVE OR INSIDE SHUTOFF SMOKE DETECTOR W/POINT ID DC NOTE: PLENUM BUILDING MANUAL PULL STATION W/POINT ID HEAT DETECTOR W/POINT ID REQUEST -TO -EXIT SENSOR DOOR CONTACTS GLASS BREAKS MAGLOCKS ON FRONT DOORS ONLY CEILING MOUNTED ELMO TSE400 CAMERA IN WEDGE HOUSING [Lc < OUTSIDE VIDEO CAMERA ON WALL MOUNT -WIDE ANGLE ELMO TSE400 1ST FLOOR PLAN 0 0 0 A T El Without Comments 3, As Noted In Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subjea to errors and . OrriiSSiOrIS which do not authorize violations of adopted I standards and orciinances. The resporsilAity for the adequacy of design rests totally with the dgner. I Additions, deietions or revisiens to these drawings artrsr this date will void this acceptance and will squire a i resubmittal of revised drawings for.subsequent approval. 11 Final acceptance is subjectto field test and inspection by The Tukwila Fire Prevention Bureau. Date: 3 By: . arts6t1L lok•Ir‘ -s\--Az-5 rrek v4-. 9t_g,14,:veti,v\?-4 EUKWILA FIRE DEPARTIVIEM Please call: 5754407 and give This lob and exact address for shut. down or restoration approve. LE FORT PORT DENT 111 7100 FORT DENT WAY TUKWILA, WASHINGTON DESIGNER:. JIM O'DONNELL DRAFTING: TRAVIS1MCCLURE OITOCIWUDN VICUIRUT7 WA. LICENSE #0440F FEBRUARY 17 1999 . • °IV NEW FIRE/INTRUSION SCHEMATICS guts 1:150 QF 2 .d MAR 5 1999 FUTURES FOR TENANT ALARM DATA, BELL CIRCUITS, a KEYPADS. f r1 x CD 01 43/ 0 r s BS LEGEND 30 CD STROBE ONLY OUTDOOR BELL -STROBE CM HO CD HORN STROBE RADIONICS 9412 FIRE PANEL SPRINKLER RISER FLOW VALVE POST INDICATOR VALVE OR INSIDE SHUTOFF SMOKE DETECTOR W/POINT ID VC OVC NOTE: PLENUM BUILDING MANUAL PULL STATION W/POINT ID HEAT DETECTOR W/POINT ID REQUEST -TO -EXIT SENSOR DOOR CONTACTS GLASS BREAKS MAGLOCKS ON FRONT DOORS ONLY CEILING MOUNTED ELMO TSE400 CAMERA IN WEDGE HOUSING OUTSIDE VIDEO CAMERA ON WALL MOUNT -WIDE ANGLE ELMO TSE400 ROOF HATCH A-41-4 of_, 2ND FLOOR 'PLAN FORT DENT 111 7100 FORT DENT WAY TUKWILA, WASHINGTON DESIGNER; JIM O'DONNELL DRAFTING: TRAVIS MCCLURE @VEITEMULA @LINNET WA. LICENSE #0440F DATE FEBRUARY 17, 1999 tz .1: NEW FIRE/INTRUSION SCHEMATICS 1:150 s'ea 2 OF 2 FLOO DLA\ @ FIRST FLOO; t1 LEGEND 4 MINI HORN/STROBE ED HORN/STROBE STROBE POWER SUPPLY: SILENT KNIGHT MODEL #: SK5395, 6 AMP. NOTE: THIS POWER SUPPLY IS FOR THE UNIVERSITY OF PHOENIX ONLY NOTE: ALL DEVICES NOT ACCOUNTED FOR IN RUN FEEDS "I" THRU "4" ARE EXISTING, AND WERE INSTALLED IN ORIGINAL PERMIT DATED 03/08/99 # 99F06A, FINALIZED 04/15/99. r FILE 0 ACCEPTED Without Comments As Noted In Red Per The Attached Letter These glans have been reviewed by The Tukwila Fire Preven ion Bureau for conformance with current city standards. Acceptance is subject to errors and omissicns which do not authorize violations of adopted standards E nd ordinances. The responsibility for the adequacy cf design rests totally with the designer. Additions, deletions or revisions to these drawings after this dat wi 1 void this acceptance and will require a resubmittal of revised drawings forsubsequent approval. Final ac ceptance is subject to field test and inspection by The Tu cwila Fire Prevention Bureau. Date- 7i/9 �/ By: UNIVERSITY OF PHOENIX FORT DENT III 7100 FORT DENT WAY TUKWILA, WA. 98188 DESIGNER: JIM O'DONNELL GERRY VUCCI DRAFTING: TRAVIS MCCLURE E@RIMo4rr WA. LICENSE #044QF DATE: JUNE 29, 1999 SIZE D IREV NEW AUDIO/VISUAL FIRE SCHEMATICS SCALE NONE SHEET I OF 1 t1.'Pt VV1LA FIRE OEPARTIVIEar Please call: 575.4407 and give this job No.fa and exact address for shut- down or restoration approval. D)Ircr',71gTVI JUN 3 0 iQaq c77-7 rb) (o%T..Zg-3 /// 25'-0" 25'-0" VOCATIONAL RM. 3 204 1, 25-0" STAIR 201 Y!I 2'-6" VOCATIONAL RM. 1 205 DN STORAGE 203 5'-0" 27'-6" 20'-0" VOCATIONAL RM. 2 206 VOCATIONAL RM. 4 209 MAINT. RM. 210 20'-0" MEN 211 a V • LIMIT OF WORK UNDER THIS PERMIT WOMEN E 212 r FACP D-9(1) TO ZONE 2 ADJACENT TENANT DN STAIR #1 FLOOR PLAN @ SECOND FLOOR 25'-0" ADJACENT TENANT 25'-0" 25'-0" 25'-0" BREAK: ZONE CONTINUATION TO THEARAPUTIC ASSOCIATES FOR POWER REQUIREMENTS. (ZONE 4) _ f DN STAIR 202 BUILDING COMMON CORRIDOR 213 ADJACENT TENANT STUDY RM. #1 217 • 50 pp . - fi M M STUDY RM. #2 218 VOCATIONAL RM. 5 216 VOCATIONAL RM. 7 214 riM VOCATIONAL RM. 6 215 0 N in N 0 LEGEND MINI HORN/STROBE: RADIONICS D559S 15/17 C.D. POWER SUPPLY: SILENT KNIGHT MODEL #: SK5395, 8 AMP. NOTE: ALL DEVICES NOT ACCOUNTED FOR IN RUN FEEDS "I" THRU "4" ARE EXISTING, AND WERE INSTALLED IN ORIGINAL PERMIT DATED 03/08/99 # 99F06A, FINALIZED 04/15/99. LIMIT OF WORK UNDER THIS PERMIT CCE TE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings forsubsequent approval UEPARTiJIENC easeKWILA call:FIRE 575.4407 a d give this job —1"°- 3 y • Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Burea Date: 7 >///1 C% By: S /"Y UL 1 41999 d exact address for shut, wn or restoration approval. B CD/e4f) 1/75 ceAr 1657' �QO j##►Ryz� �. FIL E . 1olo) UNIVERSITY OF PHOENIX FORT DENT III PHASE 2 7100 FORT DENT WAY TUKWILA, WA. 98188_ DESIGNER: JIM O'DONNELL GERRY VUCCI DRAFTING: TRAVIS MCCLURE OTIIFEM11 MMIT-211T1' WA. LICENSE #044QF DATE: JULY 14, 1999 SIZE D REV NEW AUDIO/VISUAL FIRE SCHEMATICS SCALE NONE SHEET 1 OF I INST'LL' : : + N CO x P is IVY: NEY\ELL ECU ' :CITY NIT ING 27 ICI kRI1IS %wxq} ° ®S ITE 2 2 LLE\» JE \/VA 980 #5 Fire Alarm System Check Off List For Final Inspection Following is a list of items that must be completed before the Fire Department will perform a final inspection. 1 Low Voltage Electrical Final 2 Line Voltage Electrical Final 3 Elevator Final 4 Pressurization a Stairwell b Elevator J5 Sprinkler System (100% Complete) All Valves in normal condition. 6 Interior Building Construction. (i.e. doors, floor covering, ceiling covers, ceiling tiles, windows, etc.) 7 HVAC 8 Suppression Systems 9 Safety and ADA Requirements, Fire Extinguishers _ 10 Specialty Furniture _ 11 Monitoring (See Below). _ 12 Final Fire Alarm Inspection 13 Approved Set of plans and permit on site Phone line (lines) must be installed and active. - 14 Fire Alarm Monitoring a Dual Line Communicator b Scan Line Date Line Due In: (If Required by Jurisdiction) c Contract Signed d Scan Line ordered (Alarm Company) e Stu Installed and Tested ▪ 2 Elevator Monitoring Completion Date: Completion Date: Completion Date: Completion Date: Completion Date: Completion Date: Completion Date: eV Mf ID soma Of DEVICE FCRMull. DOM Completion Date: Completion Date: Completion Date: Completion Date: Completion Date: Completion Date: A.D.A. REGULATION COMPLIANCE Completion Date: Completion Date: Completion Date: Completion Date: XP. x./23/08 GENERAL NOTES! 1) ALL WIRE AND CONDUIT MUST BE INSTALLED IN ACCORDANCE WITH PLANS AND SPECIFICATION, AND MUST MEET ALL APPLICABLE CODES. 2) ALL WIRE AND CABLE MUST BE RATED FOR FIRE ALARM USER PER THE LATEST REVISIONS, OF THE NATIONAL ELECTRICAL CODE SECTION 760. THIS IS A POWER LIMITED FIRE ALARM SYSTEM, ALL CABLE MUST BE MARKED FPL, FPLR, OR FPLP. 3) ALL CONDUCTORS MUST TEST FREE OF GROUND BEFORE MAKING CONNECTION TO THE FIRE ALARM CONTROL PANEL. 4) TO RETAIN WARRANTEE, THE FIRE ALARM EQUIPMENT MUST BE POWERED UP UNDER THE DIRECTION OF A QUALIFIED MANUFACTURER'S TECHNICIAN. 5) THE LIFE SAFETY SYSTEM IS A COMPLETELY SUPERVISED SYSTEM. MANUFIALCTURER INC U NGSPIUGESOIN IDEVICES, WI EDCEMIT RUNST AND E OPERATION IN THE SYSTEM. MANUFACTURER SHALL NOT BE HELD RESPONSIBLE CAUSED BY THOSE CHANGES. 7) LIFE SAFETY AUDIBLE SHALL BE AUDIBLE THROUGHOUT THE SPACE AND HAVE A SOUND PRESSURE LEVEL NOT LESS THAN 15db ABOVE AMBIENT NOISE LEVEL MEASURED AT 4'-0' ABOVE FINISHED FLOOR. 8) SYSTEM SHALL BE CLASS 'B' IN CONFIGURATION. 9) LOCATE ALL PULL STATION AND HORN/ STROBE UNITS AT SPECIFIED HIGH PER NFPA 72 AND ADA SEE DETAIL. 10) SMOKE DETECTOR LOCATION ARE FOR REFERENCE ONLY AND SHALL BE INSTALLED PER NEPA 72 11) ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ROUGH—IN INSTALLATION WITH THE FIRE ALARM CONTRACTOR 12) SMOKE DETECTORS IN CEILING MUST BE LESS THAN 15' FROM A WALL AND / OR NO FURTHER THAN 30' FROM EACH OTHER. 13) NO SMOKE DETECTOR SHALL BE LOCATED CLOSER THAN 36' TO ANY AIR REGISTER OR DIFFUSER 14) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 24' TO ANY AIR REGISTER OR DIFFUSER. 15) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 36' TO ANY PART OF ANY HEAT GENERATION DEVICE (FUSE, BOILERS, WATER HEATER, ETC..) IN MECHANICAL ROOMS. 16) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 18' TO ANY PART OF LIGHT FIXTURE, 17) INITIATIONCONDUIT AND SIGNALING CIRCUITS ARE SEPARATE YET MAY BE RUN IN SAME 18) ALL CONDUCTORS SHALL BE LABELED BY ZONE AND ALL COLOR CODES SHALL MATCH 19) ALL CIRCUIT FEED AND RETURN'S SHALL BE SEPARATED BY A MINIMUM OF 1' WHEN INSTALLED VERTICALLY AND 4' WHEN INSTALLED HORIZONTALLY PER NFPA72 20) THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATION TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA. 21) METALLIC RACEWAY SHALL BE USED WHEN REQUIRED BY CODE, SPECIFICATIONS AND' CONTRACT DOCUMENTS 22) ALL RACEWAYS MUST BE FREE OF MOISTURE. 23) ALL i'IRCUIT FEED AND RETURN'S SHALL BE SEPARATED BY A MINIMUM OF 1' WHEN INSTALLED VERTICALLY 'AND 4' WHEN INSTALLED HORIZONTALLY PER NFPA72 24) REFER TO HSM FIRE DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE MOUNTING BOXES. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROPER INSTALLATION OF ALL MOUNTING BOXES 25) AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE WIRING. 26) UNRELATED (NON—FIRE) WIRING SHALL NOT BE IN THE SAME RACEWAY AS FIRE WIRING. 27) ALL CONTRACTOR FIELD WIRING MUST ENTER TOP AND/OR SIDE OF FIRE CONTROL PANEL ONLY. SEE DATA SHEET. 28) ALL FIRE WIRING SHALL TEST FREE OF OPENS, SHORTS, AND GROUNDS. 29) ALL WIRES SHALL BE LABELED AND TAGGED. 30) ALL WIRE SHALL MEET ALL APPLICABLE NATIONAL ELECTRICAL CODE ARTICLES FOR FIRE AND LOW VOLTAGE WIRING. 31) THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATION TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA. DEVICE LEGEND PARTS LIST MODEL MANUFACTURER DESCRIPTION MOUNTING REQUIREMENTS D9412 BOSCH FIRE ALARM PANEL EXISTING 5395 SILENT KNIGHT 3 AMP POWER SUPPLY EXISTING MT-24MCW-FR WHEELOCK HORN/STROBE 4 SQ. BOX RSS-24MCW-FR WHEELOCK STROBE 4 SQ. BOX FMM-100SATK BOSCH PULL STATION 4 SQ. BOX D253 BOSCH SMOKE DETECTOR 4 SQ. BOX D1256 BOSCH ANNUNCIATOR EXISTING hA(;N FIRE ALARM CONTROL PANEL NACP NAC PANEL — 3 AMP ANN ANNUNCIATOR SMOKE DETECTOR HORN/STROBE STROBE F PULL STATION CCETED Without Comments As Noted In Red 0 Per The Attached Letter i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do riot authorize violations of adopted stanaaras and orainances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this.acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 6I %D/0 u By:- NOTICE A completed, signed, Fire Department Pre Certificate must be pr pr to the Inspector commencement of Testing and Detection Sy` Failure of test will in a Re -inspection l termination of the test sensed )r to eptance alarm ems. esult ee and esting• TUKWILA FIRE DEPAR7-IvtEl�d� Please call: 575.4407 and give this job No. ©8-- F300 and exact address for shut' iown or restoration approval. Checked by SHEET NUMBER FA1.O 02 F N1-1 75CD /4/2 FPLR FACP NACP 16/2 FPL 16/2 FPLR;i:' N2-1 30CD 16/2 FPLR\ N2-2 75CD 01 4/2 FPLR .2 F.:PLR ..• / 4/2 FPLR N1-4 75CD N1-3 110CD • • ::• : : • • •-• N2-3 75CD /4/2 FPLR 14/2 FPLR (2)14/2 FPLR • 14/2 FPLR 16/2 FPLR\ "c7 N2-5 30CD N2-4 75CD 14/2 FPLR / 4/2 FPLR • • ••• . • •• :•• . . " :• ... .... .. .... .• .••• N1-5 30CD F 05 (2)16/2 FPLR-\ • N1-6 30CD EOL , .. . :•• •••• •.• ..... 14/2z FPLR •:• j7 N4-3 75CD 16i2 FPL N2-6 14/2 FPLR 1 75CD 16 14/2 FPLR 2 FPL N2-7 75CD EOL Al 04 4 NACP NACP N4-1 15CD 2 FPLR 1 ' •"•••::';,•V REMAiN 04 \ 1:412-PPER N4-2 15CD \-14/2 FPLR 4/2 FPLR .16/2 FPLR-'J 14/2 FPLR 22 30CD ...... •••••••••••:,....,•••••••••••.i • 14/2..FPLR •• x:••••sf.:.:• .................................... N4-4 110CD ,••.";;;;; . • DEVICE LEGEND FACP NACP ANN F FIRE ALARM CONTROL PANEL NAC PANEL - 3 AMP ANNUNCIATOR SMOKE DETECTOR HORN/STROBE STROBE PULL STATION •,, ,i •, ,.5:K.:..W.:: .... ........... .:'.::::.•,..,..V.ViI, • ...i ,. .., : : •:. :A • :, il s•••••••••“.,•••••• • HR.:Ss": :;,••• • • . , • '•,•• irkn. N / ‘$i • :•••• \s•Mis.. V., "•:.•`::, N3-4 30CD •c7 \14/2 FPLR N3-2 75CD • s. • ••• ,,,,,, ................ 14/2 FPLR C.; ......... 14/2 FPLR N3-3 75CD 14/2 FPLR • •••.: ,,,,,,,,, ::;„:•,••••••.k. ... Z.\ N4-5 110CD "-14/2 FPLR • N4-6 30CD• 16/2 FPLIN EOL , U N3-5 ss, 75CD \-14/2 FPLR N3-6 75CD EOL 0 LO C 0 Ox IX' 00 0. 4— : < N 00 Ce3 00 N 0 N 1 1 (.), 0 LLI C.0 (Ni LO , > LdW I I O•=1—' _1 in In NLd N N c•I 03 -it -41- cn FIRST FLOOR PLAN NORTH 1/8" 1'-0" 5' 10' 20' 30' PROJECT TITLE SHEET CONTENT Job No. • Checked by Date Drawn by Scale SHEET NUMBER FA2.0 r NAC 4 N4-6 30CD N4-5 110CD 14/2 14/2 FPL FPL N4-4 110CD lir 14/2 FPL N4-3 N4-2 75CD 15CD 14/2 FPL 14/2 FPL TWO LINES TO CENTRAL STATION N4-1 15CD 14/2 FPL TELCO LINE SILENT KNIGHT 3 AMP POWER SUPPLY 5395 SILENT KNIGHT 3 AMP POWER SUPPLY 5395 120 VAC RJ31X CONN BLOCK 120 VAC N3-1 N3-2 30CD 75CD 176 14/2 14/2 FPL FPL N3-3 75CD lir 14/2 FPL RJ31X CONN BLOCK ONE—LINE RISER DIAGRAM FACP BOSCH D9412 SILENT KNIGHT 3 AMP POWER SUPPLY 5395 ABOVE FACP — 120 VAC 16/2 FPL 1 16/2 FPL F 02 120 VAC N3-4 30CD N3-5 N3-6 75CD 75CD 70r lir 11111111„:„.„. 14/2 14/2 14/2 FPL FPL FPL N1-1 75CD 14/2 FPL N2-1 30CD N1-2 15CD 14/2 FPL N2-2 75CD N1-3 110CD 14/2 FPL N2-3 75CD DEVICE LEGEND FACP NACP ANN FIRE ALARM CONTROL PANEL NAC PANEL - 3 AMP ANNUNCIATOR SMOKE DETECTOR Cr HORN/STROBE STROBE PULL STATION F NAC 3 N1-4 75CD lor 14/2 FPL N2-4 75CD N1-5 N1-6 30CD 30CD 14/2 FPL N2-5 30CD NAC 1 14/2 FPL N2-6 N2-7 75CD 75CD 14/2 14/2 14/2 14/2 14/2 14/2 14/2 FPL FPL FPL FPL FPL FPL FPL 16/2 FPL F 16/2 FPL 05 F 06 NAC 2 PROJECT TITLE SHEET CONTENT Job No. Checked by Date • Drawn by Scale SHEET, NUMBER FA3.0 • \\\\oma\��\\�\\\\\. Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building FACP Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA Bosch D9412 Fire Alarm System 1 150 300 150 300 Bosch D1256 Annunciator 1 104 206 104 206 0.55 2.2 2.2 6.20 0 0 N/A 0 0 2 0 0 N/A 0 0 2 0 0 Total System Current 0 0 0 254 506 Smoke Detectors / Auxiliary Devices Quantity of Standby Hrs. Re.uired Bosch D263 Smoke Detector 2 0.08 0.12 0.16 0.24 Bosch FMM-100SATK Pull Station 4 0.55 0.55 2.2 2.2 6.20 NIA 1.86 N/A 0 0 2 N/A 0 N/A 0 0 2 N/A 0 N/A 0 0 0 0 0 0 0 0 0 0 N/A N/A 0 0 Device Totals 6 N/A N/A 2.36 2.44 Notification Appliances (list all) Quantity of Standby Hrs. Re.uired 24 N/A 5 N/A 0 Total System Alarm rnA 508.44 N/A 6.15 N/A 0 Min. NH Battery 6.20 NIA 1.86 N/A 0 MT-24MCW-FR Horn/Strobe 110cd 2 N/A 0 N/A 0 RSS-24MCW-FR Strobe 15cd 2 N/A 0 N/A 0 RSS-24MCW-FR Strobe 30cd 0 N/A 175 N/A o 0 0 NiA N/A N/A 0 Notification Appliance Totals 0 N/A N/A N/A 0 Summary Section Quantity of Standby Hrs. Re.uired 24 Alarm Sounding Minutes 5 Total System Standby rnA 256.36 Total System Alarm rnA 508.44 Total System Standby A/I-1 6.15 Total System Alarm NH 0.04 Min. NH Battery 6.20 ADD 30% FOR BATTERY DEPLETION 1.86 Required A/H Battery 8.05 A/H BATTERY PROVIDED FOR SYSTEM Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #3 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby rnA Alarm mA Silent Knight 5395 NAC Panel 1 75 175 75 175 0 0 MT-24MCW-FR Horn/Strobe 30cd 1 0 0 o 0 MT-24MCW-FR Horn/Strobe 75cd 1 0 0 0 0 MT-24MCW-FR Horn/Strobe 110cd 2 0 0 0 0 RSS-24MCW-FR Strobe 15cd 2 0 0 Total System Current 0 RSS-24MCW-FR Strobe 30cd 0 75 175 Smoke Detectors / Auxiliary Devices Quantity of MT-24MCW-FR Horn/Strobe 15cd 60 N/A 41 0 0 MT-24MCW-FR Horn/Strobe 30cd 1 N/A 63 o 0 MT-24MCW-FR Horn/Strobe 75cd 1 N/A 109 0 0 MT-24MCW-FR Horn/Strobe 110cd 2 N/A 140 0 0 RSS-24MCW-FR Strobe 15cd 2 N/A 60 0 0 RSS-24MCW-FR Strobe 30cd 0 0 0 0 0 0 0 N/A N/A 0 0 Device Totals 0 N/A N/A 0 0 Notification Appliances (list all) Quantity of MT-24MCW-FR Horn/Strobe 15cd 60 N/A 41 N/A 0 MT-24MCW-FR Horn/Strobe 30cd 1 N/A 63 N/A . 63 MT-24MCW-FR Horn/Strobe 75cd 1 N/A 109 N/A 109 MT-24MCW-FR Horn/Strobe 110cd 2 N/A 140 N/A 280 RSS-24MCW-FR Strobe 15cd 2 N/A 60 N/A 120 RSS-24MCW-FR Strobe 30cd 0 N/A 92 N/A 0 0 0 N/A N/A N/A 0 Device Totals 0 N/A N/A N/A 0 0 N/A N/A N/A 0 Notification Appliance Totals 6 6 0 N/A 572 Summary Section Quantity of Standby Hrs, Required 60 Alarm Sounding Minutes 5 Total System Standby mA 75 Total System Alarm mA 747 Total System Standby A/H 4.50 Total System Alarm A/H 0.06 Min. NH Battery 4.56 ADD 30% FOR BATTERY DEPLETION 1.37 Required NH Battery 5.93 A/H BATTERY PROVIDED FOR SYSTEM \\\\\oma \•\\ �: Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #1 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Silent Knight 5395 NAC Panel 1 75 175 75 175 0 0 MT-24MCW-FR Horn/Strobe 30cd 4 0 0 0 0 MT-24MCW-FR Horn/Strobe 75cd 7 0 0 0 0 MT-24MCW-FR Horn/Strobe 110cd 1 0 0 0 0 RSS-24MCW-FR Strobe 15cd 1 0 0 Total System Current 0 RSS-24MCW-FR Strobe 30cd 0 75 175 Smoke Detectors / Auxiliary Devices Quantity of MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 0 0 MT-24MCW-FR Horn/Strobe 30cd 4 N/A 63 0 0 MT-24MCW-FR Horn/Strobe 75cd 7 N/A 109 0 0 MT-24MCW-FR Horn/Strobe 110cd 1 N/A 140 0 0 RSS-24MCW-FR Strobe 15cd 1 N/A 60 0 0 RSS-24MCW-FR Strobe 30cd 0 0 0 0 0 0 0 N/A N/A 0 0 Device Totals 0 N/A N/A 0 0 Notification Appliances (list all) Quantity of MT-24MCW-FR Horn/Strobe 15cd Standby Hrs. Required N/A 41 N/A 0 MT-24MCW-FR Horn/Strobe 30cd 4 N/A 63 N/A 252 MT-24MCW-FR Horn/Strobe 75cd 7 N/A 109 N/A 763 MT-24MCW-FR Horn/Strobe 110cd 1 N/A 140 N/A 140 RSS-24MCW-FR Strobe 15cd 1 N/A 60 N/A 60 RSS-24MCW-FR Strobe 30cd RSS-24MCW-FR Strobe 30cd N/A 92 N/A 0 0 0.14 N/A N/A N/A 0 0 = N/A N/A N/A 0 0 N/A N/A N/A 0 Notification Appliance Totals 13 6 0 N/A 1215 Summary Section Quantity of Standby mA Standby Hrs. Required 60 Total Device Alarm Sounding Minutes 5 Per Device Total System Standby mA 75 Alarm mA Total System Alarm mA 1390 126 Total System Standby NH 4.50 0 Total System Alarm NH 0.12 436 Min. A/H Battery 4.62 0 ADD 30% FOR BATTERY DEPLETION 1.38 0 Required NH Battery 6.00 1 NH BATTERY PROVIDED FOR SYSTEM u Battery Calculation Worksheet (all currents stated in mA) 6/1/2008 PROJECT: Fort Dent Office Building NACP #2 Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Silent Knight 5395 NAC Panel 1 75 175 75 175 41 N/A 0 MT-24MCW-FR Horn/Strobe 30cd 0 0 63 N/A 126 MT 24MCW-FR Horn/Strobe 75cd 0 0 109 N/A 436 MT-24MCW-FR Horn/Strobe 110cd 0 0 140 N/A 0 RSS-24MCW-FR Strobe 15cd 0 0 Total System Current N/A 0 RSS-24MCW-FR Strobe 30cd 75 175 Smoke Detectors / Auxiliary Devices 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Device Totals 0 0 0 Notification Appliances (list all) NACP #1 „xY MT-24MCW-FR Horn/Strobe 15cd N/A 41 N/A 0 MT-24MCW-FR Horn/Strobe 30cd 2 N/A 63 N/A 126 MT 24MCW-FR Horn/Strobe 75cd 4 NIA 109 N/A 436 MT-24MCW-FR Horn/Strobe 110cd 0.063 N/A 140 N/A 0 RSS-24MCW-FR Strobe 15cd 0.109 NYA 60 N/A 0 RSS-24MCW-FR Strobe 30cd MT-24MCW-FR Horn/Strobe 110cd N/A 92 N/A 0 0.14 N/A 0.06 N/A 0 = 0.06 N/A RSS-24MCW-FR Strobe 30cd N/A . 0 = N/A N/A 0 Notification Appliance Totals 6 0 N/A 562 x = 0 Summary Section Standby Hrs. Required 60 Alarm Sounding Minutes 5 Total System Standby mA 75 Total System Alarm mA 737 Total System Standby A/H 4.50 Total System Alarm NH 0.06 Min. NH Battery 4.56 ADD 30% FOR BATTERY DEPLETION 1.37 Required A/H Battery 5.93 NH BATTERY PROVIDED FOR SYSTEM FORT DENT OFFICE BUILDING III - UNIVERSITY OF PHOENIX Panel NACP #1 „xY 1 REVISIONS I Circuit Device Current # of Devices Current N1 MT-24MCW-FR Horn/Strobe 15cd 0.041 X = 0 MT-24MCW-FR Horn/Strobe 3ocd 0.063 X 2 = 0.126 MT-24MCW-FR Horn/Strobe 75cd 0.109 X 2 = 0.218 MT-24MCW-FR Horn/Strobe 110cd 0.14 X 1 = 0.14 RSS-24MCW-FR Strobe 15cd 0.06 X 1 = 0.06 RSS-24MCW-FR Strobe 30cd 0.092 X = 0 X = 0 x = 0 X = 0 Total Current 0.544 Panel NACP #1 Circuit Device Current I # of Devices Current N2 MT-24MCW-FR Horn/Strobe 15cd 0.041 X = 0 MT-24MCW-FR Horn/Strobe 30cd 0.063 X 2 = 0.126 MT-24MCW-FR Horn/Strobe 75cd 0.109 X 5 = 0.545 MT-24MCW-FR Horn/Strobe 110cd 0.14 X = 0 RSS-24MCW-FR Strobe 15cd 0.06 X = 0 RSS-24MCW-FR Strobe 30cd 0.092 X = 0 x = 0 X = 0 X = 0 Total Current 0.671 Panel NACP #2 Circuit Device Current # of Devices Current N3 MT-24MCW-FR Horn/Strobe 15cd 0.041 X = 0 MT-24MCW-FR Horn/Strobe 30cd 0.063 X 1 = 0.063 MT-24MCW-FR Horn/Strobe 75cd 0.109 X 1 = 0.109 MT-24MCW-FR Horn/Strobe 110cd 0.14 X 2 = 0.28 RSS-24MCW-FR Strobe 15cd 0.06 X 2 = 0.12 RSS-24MCW-FR Strobe 30cd 0.092 X = 0 x = 0 X = 0 x = 0 Total Current 0.572 Panel NACP #3 Circuit Device Current # of Devices Current N4 MT-24MCW-FR Horn/Strobe 15cd 0.041 X = 0 MT-24MCW-FR Horn/Strobe 3ocd 0.063 X 2 = 0.126 MT-24MCW-FR Horn/Strobe 75cd 0.109 X 4 = 0.436 MT-24MCW-FR Horn/Strobe 110cd 0.14 X = 0 RSS-24MCW-FR Strobe 15cd 0.06 X = 0 RSS-24MCW-FR Strobe 3ocd 0.092 X = 0 X = 0 X = 0 X = 0 Total Current ii 0.562 EOL 3.19 169 X 0.544 0.293 23.707 1000 12ga. 2 cond 1.5912 14 ga, 2 cond 3.1912 EOL 3.19 166 1000 X 0.671 0.355 23.645 12ga. 2 cond 1.5912 14 ga, 2 cond 3.1912 EOL 3.19 120 1000 X 0.572 0.219 23.781 12ga. 2 cond 1.5912 14 ga, 2 cond 3.19 i2 EOL 3.19 224 1000 X 0.562 0.402 23.598 12ga. 2 cond 1.5912 14 ga, 2 cond 3.19 0 a' tf) d COC o) D rr .< a W E N a W O f- J t� 5 W v)m N 00 O 0 N (n to tf) Lf) N N d' "t' 0 *lam a. uJ u. w 0oCI r bi - r�pJ i�l� Rai w, o z „CI I z r SHEET CONTENT f. o L1 _ Iw < o Q J _J O V Job No. Checked by;; Date Drawn by Scale SHEET NUMBER FA4.0 „xY 1 REVISIONS I s IH 3.4 CO M a 1 ` r 0 *lam a. uJ u. w 0oCI r bi - r�pJ i�l� Rai w, o z „CI I z r SHEET CONTENT f. o L1 _ Iw < o Q J _J O V Job No. Checked by;; Date Drawn by Scale SHEET NUMBER FA4.0 0 0 rn 0 J w 0 Li N c 0 0 c Y +S 0 N O cu la. oO is o- • 00 Li - /1 �m 1a se mcsj Ea5iFF o M II 4- to mar-- rn c„ E 822 I=cnox io Without Comments As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards, Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or -revisions to these drawingssafter this date will vold this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Prevention Bureau. Date"I1 ..ay: ,ItILVAILA FIRE QgP Please oat!: 575 azii give this No" 10 I OD and ficact address 'fix Own or restpratten p C ti s,,vse S Indke 6I, f. clove FA -c p q v PS . ' L11)04. vrcii4,' Ivoloi LtCt 2 0%, (ACa (4W (Ace 4ti0t c; c,,;-- LjrYgktvs • NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. MANUFACTURE MODEL DESCRIPTION SYMBOL SILENT KNIGHT 5495. POWER SUPPLY I FC -9 5 SYSTEM SENSOR P2R/SR HORN/STROBE STROBE 13 21 Ex151-(nl, CO 5 (-0 ° • 0 Dem L' A- -G O ARIL LLI-Y E0 (r\ exlei i (AL A- F I 9..e. Al. -\ o "SCOPE OMORK" INSTALLAN AUTOMATIC FIRE A , RMSYSTEM IN A y 5 n (c Ce �.. ALL WIRE TO BE I:PLR-MIN 18AWG, 16AWG FOR NAC CIRCUITS. ALL STROBES TO BE AT 80" ON BOTTOM, HORNS TO BE 'T5 DB MINIMUM THROUGHOUT. ALL PULL STATIONS AT 48" ON TOP. MONITORING VIA UL LISTED CENTER STATION. A FULL-SERVICE AGREEMENT IS IN PLACE TO ASSURE PROPER TESTING. AND MAINTENANCE PER NFPA 72 STANDARDS. ALL WORK TO BE PERFORMED IN WOF -,MAN LIKE. FASHION. INSTALLATION SHALL . MEET NFPA 72, UBC, UFC, WAC, IFC AND ANY • LOCAL AIH CODES. A FULL PRE-TEST SHALL BE COMPLETED PRIOR TO CALLING AHJ FOR FINAL ACCEPTANCE TEST. Ps OPEN WORK AREA 13'-0" CONFERENCE 202 1200IAIa TRAINING ROOM 204 NOT IN SCOPE 203 I A OFFICE 205 OFFICE 206 FEC ILIMENINEI PORIUMEMUI II KITCHEN 200 OPEN WORK AREA 201 \/\ '1-0 e5 n f9 -c 16 -112ce_ NOT IN SCOPE 0 FIRE ALARM SCALE:3/16" = 1'0" ) NORTH CONSTRUCTION LEGEND. FEC EXISTING BUILDING CORE: EXISTING 1 -HOUR RATED CORRIDOR PARTITION. EXISTING DEMISING PARTITION, NEW BIS TENANT INTERIOR PARTITION. SEE DETAIL 7/TI-1. NEW BIS 1 -HOUR RATED PARTITION. SEE DETAIL 6111-1. NEW 8/S 2'-0" WIDE X FULL -HEIGHT TEMPERED SAFETY GLASS RELITE. NEW BIS FIRE RATED 6-0" WIDE X 4'-0" HIGH PARTIAL HEIGHT TEMPERED SAFETY GLASS RELITE ASSEMBLY IN ACCORDANCE WITH ASTM E 119. EXISTING, U.N.O., FIRE EXTINGUISHER CABINET. ALIGN. CONSTRUCTION NOTES 1. ALL WALL INFILLS TO ALIGN WITH ADJACENT SURFACES ON EACH SIDE. 2. CONTRACTOR TO PROVIDE AND INSTALL BLOCKING FOR ALL DOORS, ACCESSORIES AND CABINETRY, IF REQUIRED. 3. FOR GENERAL NOTES, SEE TI -1. CONSTRUCTION KEYNOTES EXISTING 60 -MINUTE RATED CORRIDOR. 2O CONTRACTOR TO CHECK CONDITION OF INSULATION ABOVE EXISTING DEMISING PARTITION AND REPAIR AS REQUIRED TO BRING TO "LIKE NEW" CONDITION. CONTRACTOR TO RE -INS DEMOLITION KEYNOTE LOCATION. LL REMOVED WHITEBOARD PER ). VERIFY WITH TENANT EXACT 0 CONTRACTOR TO MODIFY HARDWARE OF EXISTING DOOR BY PROVIDING AND INSTALLING B/S PANIC HARDWARE. O CONTRACTOR TO PATCH OPENINGS LEFT BY REMOVAL OF CONTROL SWITCHES AND TO FINISH TO MATCH ADJACENT. O6 CONTRACTOR TO PROVIDE AND POST A SIGN INDICATING MAXIMUM OCCUPANCY OF (63) IN ROOM. EXACT LOCATION IS TO BE DETERMINED. O7 CONTRACTOR TO PROVIDE AND POST A "NOT AN EXIT" SIGN AT THIS A DOOR, DOOR SCHEDULE DOOR NUMBER TYPE OF DOOR A. NEW B/S 3'-0" WIDE X (t) 8'-0" HIGH X 1-3/4" THICK SC WOOD DOOR IN BIS WOOD FRAME. B. NEW B/S 45 -MINUTE 3'-0" WIDE X (t) 8'-0" HIGH X 1-3/4" S.C. WOOD DOOR AND METAL FRAME ASSEMBLY. HARDWARE a. B/S LATCHSET. b. B/S LATCHSET AND CLOSER. c. BIS PANIC HARDWARE. 6", UNLESS OTHERWISE NOTED NOTES: EXISTING DOOR TO REMAIN 1. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO BE LEVER -TYPE, HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO UTASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, FINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 2. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 FOUNDS (222 N), SLIDING OR FOLDING DOOR = 5.0 POUNDS (22.2 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR INA CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 3. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.5 INCH (12.7 MM) IN HEIGHT. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THIN 0.25 INCH (6.4 MM) AT DOORWAYS SHALL BE BEVELED WITH A SLOFE NOT GREATER THAN ON UNIT VERTICAL IN TWO UNITS HORIZONTAL(50-PERCENT SLOPE). FORT DENT SII 6840 FORT DENT WAY TUKWILA, WASHINGTON 98188 Fire Protection, Inc. 1730 GIBSON ROAD EVERETT, WA 98204 (425) 290-9600 o 800-6 1- 125(Phone)425-3. Fire Protection, Inc. 1730 GIS80 OAD, EV RETT, A 98 04 DRAWN BY CONT#FIREEPL*031 Mi., LI#CATS*RL 022CL' SEATTLE FIRE CE(3T,#SLrP-(-9955 N I C ET#4- #Ou r ;3::t? CFPS#147e PROPERTY OF AND ALL RIGHTS RESE9D ` FIRE PFIDIEoriON,•INC. DATE • 77 °TECri3O 0008 1 ans at dha4 CFPS® *1473 Marvin Ste planning sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441-1449 DRAWN BY: MW CHECKED BY: SN, GG JOB NO.: 08153.006 NO. REVISIONS INDICATED THUS 0 SUBMITTAL FOR REVIEW TENANT: STATE FARM INSURANCE (SECOND FLOOR) SHEET TITLE: FIRE ALARM PAID MAY 212010 TUPVVILA FIRF 0' PRI`0, OFF. STAFF ENT. 0 z w`. 0i SUPPLY CABINET CONSULTATION 7 2 sr OP #1 RECEPTION ROOM MAIN ENT. PT.'S LAV. 1 1 1 1! III AL as.s r.aun d. awns -s role In pips 11'!.7 Full flow oudr -:ign.ct 0ualiN can iron Ime, el Ioesdng edlar Sforted bort z.nings adaw for incvdauon won anh on. nus rsmw.d. 110 ,1011 7rte � .1 ULC,)1 L New Tee -Lox' Mechanical Branch Connector From CPLD AOPProved • sc. sc. 3 31ozsourp, '531: • VVAnO making in Arvnrn PROPOSED LAYOUT ( 12 P1•1 ;cAlo,f 4 E R E .iTr, i& e�Grli T 6 R RE (ocn�G r 2 v� oveLv 7©r'r+-C- Z¢ RoLiferb& llaD eL 6-4 /''Fd111 /k5° 4.4'i2- ‘514 4'/2 vrQ FI)C p&p/ F/M2,9>'tll A!L /-u reel ;AEI U. L r F.(1, 2 WASHER/ DRYER STACKED 2 1 -- 2 .r - RETAINER STRAP WHERE REQUIRED IN SEISMIC AREAS TOP BEAM/ C -CLAMP WITH SET SCREW 3/8' ALL THREAD ROD PIPE SWIVEL RING STEEL JOIST/TRUSS HANGER DETAIL NTS NORTH Timariemwrismearemasaas~~.........~~was7 ECCE T 4r rtYKWILA FIRE DEPARTMEN1 Please call: 575-440Z end give this job 8— a o 8 and exact address for shuts clown or restoration approve!: CRO/N FIRE PROTECTION ACTION INCORPC)FRAT`D P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 48}-7669 Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do riot authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions tv these drawings after this date will void this,acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /0-Z °� By 4 rl1' PAID OCT 252005 Tukwila Fire DENTAL OFFICE BUILDING D R. '' 7\00 Mr+ Dtni toot' �0 \ 2_10r 13, 1d1/4. fi 1-0\ i 1a/ lam, DATE: iD• I DRAWN: LM 1 SCALE: or / 122 MEM MIN JO= ME* s2a =ES 22= MOW - /c 0"DE .II= =2 C=2 2222 2E= 112= is=r111=C 2222 giftr BEN IIMIZ 1105112 V= =MI =2" pout'rt . DeTiarc-tor- cmSC- C VA LAW A55FeM+bLy, comocexe- \Auer 4'IARV PDL- 15*-: oTHEAS r 0 1 1 1 1 1 1 1 %0~ et -er- 1 6bI :s's )0)X RISER ROOM'S b"D1 emni pen me S5 t 0=10" _I �.x►a• INET R15tR NEW WLD 1 W61 w/ NEW ASS• gXTER IOR CAN copy NONCOM /5 ti ST1 dk.t N.A+4. WATER SUPPLY INFORMATION STATIC RESIDUAL FLOW 155 PSI 105 PSI 1671 GPM AT 105 PSI THIS INFORMATION WAS PROVIDED BY THE PUBUC WORKS DEPARTMENT OF THE CITY OF TUKWILA. SITE PLAN (11) 10 • 20 30 40 50 awllwok ��� rs�w ��F • aali!! ■ mrr` �� �+�kc �:�+e txa; ■ �� � �xi � ray �� � �; ��� � }w� ■ SCALE 1" = 20' Pew, aBG C.ONSTRUCTIO14 TYPE : 1 t 1-14(SPRtNKU&RP.D) OCCUPANCY GWZUPS: 8 -OFFICE. �-- r _e // YE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted i standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. 1 Additions, deletions or revisions to these drawings after 1 this date will void this acceptance and will require a resubmittal of revised drawings forsubsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 4/ y(q 7 By:t-,-/C-5-0- AO /Cs /Z TUKWILA FIRE DEPARTMEN1 Please call: 575-4407 and give this job No. Fq -2.0 T d exact address for shut' down or restoration approval. Fit E 1',Rt;tt e...0n151% s'ntc, —1115'5" So, 206 Tr, Rzer _ • 14.6.2,774 r wA , q rot r ED APPROVED BY: SCALE: /Ja DATE: �lTY op- TutCw i L6q DRAWN BY 8. P REVISED VNIVL=_-R-Srry cif. PttOEN -100 FotLr Flc 0R) '-s-v Kw t_r4 wA • DRAWING NUMBER P✓/4A/ 1 QF ly4Wy,E.inre..v!a,T.)r.o,,.T^.tr.v4;rMv^•>•r•.rf+C%r!T��:^'rJ"::.�'�.�'(Lwi:iFili:Y:4n GENERAL NOTES:. 1. ALL EXISTING LINE PIPING IS 11" 2. ALL EXISTING MAIN PIPING I5 4" 3. ALL EXISTING PENDENT SPRINKLER HEADS ON FIRST FLOOR ARE RELIABLE MOD. G XLO-ECOH 1" CHROME RECESSED, MAXIMUM SPACING I5 16 X 16, 4. MINIMUM SPACING BETWEEN XLO-ECOH SPRINKLER HEADS I5 13 FEET. 6. TIE INTO EXISTING LINES USING 1" X 1" MECH. TEE 7. TIE INTO EXISTING MAINS USING 4" X 1" MECH. TEE 8. EXISTING SPRINKLER SYSTEM I5 DESIGNED TO A DENSITY OF .15 GPM OVER 1500 SQUARE FEET 9. LINE HANGERS TO BE 3/8" QUICK BOLT OR 3/8" TOP BEAM CLAMP WITH 3/8" ROD AND HANGER RING 10. WHERE SPRINKLER HEADS ARE SPACED CLOSER THEN 13', USE RELIABLE MOD. G I" RECESSED SPRINKLERS FLOO R RI- SP\K P A\ 99 NORTH ARCHER AA!. Orrr 10' 12' 14' 16 18' 20' NOTES REVISIONS SPRINKLER SYMBOLS DATE DESCRIPTION BY ENIST• Ss P ro RE-Ltt Mob, G XI -O - EL&F} CtiCortle H,5° . Q l.oc4Te (.1si. 55P 68 }ADD ,\ S P RLL F %LI Mob . Gi ) Lo - ( coH cH2or' E 165° Re.. 3Z toe) UNIVERSITY OF PHOENIX . FORT DENT THREE 7100 FORT DENT WAY TUKWILA, WA. 98188 ARCHER CONSTRUCTION INC. 7855 S. 206TH STREET KENT, WA. 98032 PI -L* 253-872-7222 FAX* 253-872-7277 FIRE SPRINKLERS PERMIT NO. CONTRACT NO. APPROVAL CITY OF TUKWILA C.D.T. BOB POPKE SCALE NOTED DATE REVISED PLOTTED 6/4/99 2.-10F 2- .. • • • . .• -77**"... • L, „ ••• ••••••Otr.- VatiONS conditions 1.1irtt n strued as heating in sny-ra, Ativo •thri. an eidrcised ith resisect .; rut, sr *page to rropert tt Vs • tost, t in loss stilt mast, •,: , ALL EXISTING MAIN PIPING IS 4" ARCHER CONSTRUCTION INC. 7855 S. 206TH STREET KENT, WA. 98032 MMEETMIIT JUN 1 8 19 .......... ........ ..... k 25'-0' k 25'-0' 140`-0' 20'-0' k 20'-0' 25'-0 25'-0' 25'-0' 25'-0' e f tJ cri \.J 1 -4 J t ; /-T4& p " 3 � � i -4— 4-- 0 1---1!,:r- 4-1,X 2"-t----��© -1-- t i r • s f 1 T I --1 !/I .�4 -•r► 2X its - 1111_ I 22. j fd1 I t + : _ L -4 --r--- co MAINTENANCE 1 0 MEN 1 _4Th - WOMEN _ { 1 1 I 8D I rI j i i �. 1 L fes_ w I r� I ' +f 3 4N J 2' b 1t �';460 --� J i i — /tZt 414, 1 f� HYDRAULICALLY REMOTE AREA HYDRAULICALLY CALCULATED TO DELIVER .15 GPM/SQ FT OVER 1500 SQ. FT - SYSTEM DEMAND 677.42 GPM REQ'D AT 123.43 PSI AT BASE OF RISER 1 ► r- I -3 1 - i t`0 5 , Z 1 Y- 1 «-' - P -414- 414- i , i rA- 0 0 8 f — —,-tit- — +-- — 4 1t1 f 1 i t� fI ` -: t I' , --r--t}-t-t:►- .-- 'VIA -41 1 --- 1 012f0.f .r f -8- I,Q'2-0 4i TS 48D5. 1 1/ UILDING CORRIDOR ELEVATOR x tit = EXISTING SPRINKLER HEAD TO REMAIN • = .KIDDED OR RELOCATED SPRINKLER HEAD tat = EXISTING SPRINKLER HEAD TO BE RELOCATED - - = EXISTING SPRINKLER LINES = PARTIAL -HEIGHT WALLS FL00� DLA\ (Seconc Floor) 2 — `X 16—C}. 0 e 1, 1 I1 tit _; SCOPE OF WORK: 1 ADD /(14) AND RELOCATE (8) SPRINKLER HEADS FOR FULL -HEIGHT WALLS OF ) C7) GENERAL NOTES: I EXISTING PIPING IS 2" GRID LINES WITH 3" MAIN HANGERS TO BE BEAM CLAMPS WITH RETAINER STRAPS (TYPE '0' HANGER). I MAINTAIN EXISTING 16' x 16' SPRINKLER HEAD _SPACING. 0 ll - HANGER LEGEND A tJ HOOK COACH SCREW ROD BM. CLAMP W/ STRAP EYELET FLUSH SHELL CEILING FLANGE SIDE BEAM BRACKET SHORT CLIP ALL THREAD ROD TOGGLE NUT - POWDER DRIVEN STUD EXPANSION BOLT PIPE SPIKE STATE CERTIFICATION SPRINKLER LEGEND or a. fib orincERINKLEsrzEsit :2z 2 Ej 3/4 SPRAY ci u 1 - DRY TYPE 2 - WAY EARTHQUAKE BRACE + - WAY EARTHQUAKE BRACE TEMP RATING }-.) STRUCTURE TO CENTER LINE OF PIPE IN INCHES FITTING LEGEND 0 165. 284. bas 500. zfr a. 4/4 cr g 21 118 iie2-TOD 1/2 PLAIN END FIT FITTING APPROVAL REQUIRED SH GROOVED SHAPED NIPPLE CITY OF TUKWILA TSH THREADED SHAPED NIPPLE SPRINKLER HEADS USED SYM MANtlf MODEL TYPE THREAD ORIFICE SIZE SIZE NEW FINISH ESCLITCH FINISH TEMP QTY • FRIABLE 03.0-ECOH EC COY PDIDDIT 3 114 CHROME CHROME 165 14 TOTAL QUALJT'f CONTROL BY DATE APPROVED FOR FABRICATION BY DATE GENERAL NOTth' 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND Ul. USTED OR FM APPROVED. 2. PIPING DIMDISIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS - SHOWN THUSLY 0-1) WHICH ARE END TO END. 3 EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH AC EPT VVitho .1- Comments As %tad In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards Acceptance is subject to errors and omissions which do not authorize violattons of adopte standards and ordinances The responsibility for the adequacy of design rests totally with the designer Additions, deletions or revisions to these drawings aft this date will void this acceptance and will require a resubmittal of revised drawings for,subsequent appro Final acceptance is subject to field test and inspect] The Tukwila Fire Prevention Bureau 1 litilD) I VICINITY MAP: N.T.S. 6. 8. 9 10. NO PIPE HANGERS AND METHOD Of HANGING TO BE IN ACCORDANCE WITH PIPING SHALL BE IN ACCORDANCE WITH PIMA PAMPHLET WO. 13. APPUCABLE EDITION JOINING Of PIPE AND FITTINGS, THREADED 1 WELDED. SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO, 13. APPUCABLE EDITION. CANER TO PROVIDE ADEOUATE HEAT 11. AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. AU. WIRING Of ELECTRICAL DEVICES OF REQUIRED) TO BE PROVIDED - BY OTHERS PAINTING Of PIPE & EQUIPMENT (W REQUIRED) TO EIE PROVIDED BY OTHERS FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA MAINTAIN EXISTING 16' x 16' EXTENDED COVERAGE SPACING: Please call: 575-4407 and give this job and exact address for shut- down or restoration approval. DATE PIPE NOTES REVISIONS DESCRIPTION .CONTRACT WM& - NEW WEST CONSTRUCTION 5837 22t ST PLACE S.E. ISSAQUAH, WA 98027 r FILE PROJECT NAME: THERAPUTIC ASSOCIATES -7100 FORT DENT WAY T 10 fIRE PROTECTION - 2707 70TH AVENUE EAST -4' FAX- (206) 922-6150 DESIGNER DAVE USIECKI 08 NO. 6-23-99 12-.4615 IAA AA - • REVISIONS DESCRIPTION 207 209 212 0" ELEVATOR LOBBY DN. S A RS OPEN TO BELOW HANGERS ABBREVIATIONS WATERFLOW INFORMATION \ MTH FIRE SPRINKLER PLAN 1/8" = 1' SPRINKLER SYMBOLS . • BY 'IP,: BEAM CLAMP W/ Rt, i RAP • . P TRAPEZE SIDE BEAM BRACKET , EYE SOCKET - NUT & PLATE WASHER .49 KWIK-BOLT HUIP SAMMY SIDEWINDER. SAMMY SUPERSCREW COACH SCREW ROD CEILING FLANGE ic • U -HOOK SHORT ST IV\ P WALL BRACKET . • AFF BOB BOD BOJ BOP BOT CTS • FO IFOW OFOW NAS UNO 8 pF ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE RIGID COUPLING FLEXIBLE COUPLING STATIC XX PSI SYM MAKE MODEL TYPE FINISH K -FAC. THREAD ORIFICE TEMP CANOPY QTY RESIDUAL XX PSI GPM FLOWING )00(X GPM DATE & TIME . XX/XX/XX PER: CITY OF SEATTLE WATER LOCATION: GENERAL NOTES 1. EXISTING SPRINKLERS ARE RELIABLE ECQR RECESSED PENDANTS 2. MAX. DISTANCE BETWEEN SPRINKLERS IS 16" 3. ALL ARMOVERS OVER 12" SHALL BE SUPPORTED WITH A HANGER 4. SPRINKLERS SHOWN ARE IN AREAS OF REMODEL ONLY r FORT DENT III 2ND LEVEL LOCATION PLAN NTS FIRE SPRINKLERS = = EXISTING SPRINKLER TO REMAIN 2 Re = EXISTING SPRINKLER TO BE RELOCATED PLG 1 = EXISTING SPRINKLER TO BE PLUGGED 3 TOTAL SPRINKLERS NOTES: TOTAL PROJECT SPRINKLERS LI TOTAL SPRINKLERS THIS SHEET FIRE SPRINKLER DIVISION 7855 S 206TH STREET, KENT, WA 98032 PHONE 253-872-7222 FAX 253-872-7277 CCEPTE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions whichdo not authorize violations of adopted standards and ordinances. The responsibility for the adequacy, of design rests. totally with the designer. Additions, -deletions or revisions to these drawings after this date will void.this,acceptance and will require a resubmittal of revised drawings. for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 9/057 By: FILE 0'0on, hie .40 co° Co Nit ...S1 TUKWILA FIRE DEPARTMENI, Please call: 575-44R and give this job No. 0S-6)- 0•S' and exadt address for shut down 'or restoration approval.. Springy Dace STATE FARM -uav -6840 FORT DENT WAY (BLDG. #3 2ND FLR.) TUKWILA,WASH. CONTRACTOR: FOUSHEE AND ASSOCIATES PHONE: 425-746-1000 FAX:• •425-746-3737 FIRE SPRINKLER PLAN PERMIT NO: - JOB NO: AUTHORITY: CITY OF TUKWILA DESIGNER: BOB POPKE SCALE: NOTED DATE: FEBRUARY 4, 2005 REVISED / / FP 1 OF 1 PLOTTED /1 FEB - i Z005 '1;47 TUKWILA FIRE DEPARTMEN/ Please call: 575.4407 and give this jot) No. Oc:-6— /7l end exact address for shut, down or restoration approval O CCEf'TE Without Comments As Noted In Red Per The Attached Letter These plans havf: a..::_ n reviewed by The Tukwila Fire Prevention Buri Scr conformance with current city standards. Aa.;.l,f::::.. t 14 subject to errors and omissions which . i nt_q atrtr-,_,, ze violations of adopted standards a:lu I' ne responsibility for the adequacy Isley with the designer. Additic s, i , .I.. •> is n` to these drawings after this dear+:° : j rh;1Ue and will require a resubmittal l.1! rings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila FireirPrevention Bureau: Date: cl/ 105— By12W n SPRINKLER PLAN SCALE: 1/8" =1'-0" NIC ay NIC \\\ NIC A 1— f\ NIC 7 NIC NIC NIC NIC NIC NIC NIC r" R • 1-2 o° elf ,„av'f\ ti '475.1 STEEL BAR JOIST —TOP BEAM CLAMP W/ RETAINER STRAP FASTENED W/ (2) NUTS & WASHER ALL THREAD ROD ----HANGER RING HANGER A BEAM CLAMP a rA SCOPE OF WORK: F0LE 1. ADD & RELOCATE REQUIRED SPRINKLERS FOR NEE CE IING AND WALL LOCATIONS. 2. WET SYSTEMS TO BE DESIGNED PER NFPA #13 C1:11 A H RD. 3. PLAN SUBMITTAL TO AND APPROVAL BY CITY OF TUKWILA. 4. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY ARCHER CONSTRUCTION. 5. TESTING PER NFPA #13 (1999) AND CITY OF TUKWILA. 6. NEW CEILING AND WALLS DO NOT AFFECT EXISTING UPRIGHT SPRINKLER PROTECTION. CLARIFICATIONS: 1. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED AT A MINIMUM OF 40°F (BY OTHERS) IN ORDER TO PREVENT THE PIPE FROM FREEZING. EXCLUSIONS: 1. TAXES OF ANY TYPE. 2. ELECTRICAL OF ANY TYPE. 3. RELOCATION OF EXISTING LINES AND MAINS FOR WORL OF OTHER TRADES 4. STRUCTURAL VERIFICATION AND ABATEMENT OF ANY TYPE. 5. LABELING, PREP FOR & PRIMING OR PAINTING OF ANY TYPE. DESIGN CRITERIA: 1. CRITERIA BASED ON NFPA #13 (1999 EDITION) & CITY OF TUKWILA CODES. FITTER NOTES: 1. HANGERS: * ALL PIPE HANGERS TO BE BEAM CLAMP. SEE HANGER DETAIL 'A' ON SHEET FPI. 2. MAXIMUM HEAD SPACING TO BE 225 SQ. FT. 3. ALL THREADED PIPING TO BE ALLIED XL JOINED W/ THREADED FITTINGS AND COUPLINGS. SPRINKLER HEADS '`. = EXISTING RECESSED PENDENT Rio = RELOCATE EXISTING RECESSED PENDENT A0 = ADDED RECESSED PENDENT a q dy Poi trr c tl' l 139thSt ,s `PS �kb rinke l I N isS o 1. Iti1 5' •Oil lfi/t c, ,,, S 142nd St ` 58th five s N S 144th St I S 151st St 3 N S 147th St S 15019 Sl S 1501 S 152nd S1 S 15411, St 5 143rd St S 149th S1 PI 31 h o, ro •a S I @2nd PI -• o S 153rd 9 'S°4(/lCeh1N• ejvy C0 N S 143rd PI n7 no Monster Rd Sw • 101P0t Bi, * s1541n5t eS il01 ¢Un St pent- Tuk Park Sw416 ,, ar 5 S,v 7th Sty 518 Cryital Springs Fork S151stStS1Co1],31 N 3 183rd FI ' S 164th St % N S 15719 Sl S 155119 Ln 156th s1 , Tukwila 150". Soirthcenter _ - Nrestffnlif ' ' ShnpF7ngMna . SnUlbrnhtnr, VICINITY MAP SCALE: NTS Tukurila Pend 0. 41 m Baker Olvd Stondet $‘"1a Treck Dr Indust_ -n DD . nnring l,nnrr;CreS hvineld:d Park Oa kesdaic Av S)V aro, St Sly 3rd pJ Sw Sunset Blvd Shysrh cr Sr4.5, fi -a 0)qa q E 50/10114 91 Sw 120 91 Sw 16th Sl Sw 2719 St = FULL HEIGHT WALL = PARTITION WALL(NOT FULL HEIGHT) REVISIONS HANGERS ABBREVIATIONS WATERFLOW INFORMATION SPRINKLER SYMBOLS DATE DESCRIPTION BY A BEAM CLAMP W/ RETAINING STRAP AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO o ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE RIGID COUPLING FLEXIBLE COUPLING STATIC PSI SYM MAKE MODEL TYPE FINISH K -FAC. THREAD ORIFICE TEMP CANOPY QTY RESIDUAL PSI 0 RELIABLE QR, F1 RECESSED PENDENT CHROME K=5.6 155° CHROME 7 GPM FLOWING GPM DATE & TIME PER: CITY OF LOCATION: ARCHER CONSTRUCTION, INC THERA] EUTICS ASSOCIATES FORT DENT 3 7100 FORT DENT WAY TUKWILA, WA 98188 THERAPEUTICS ASSOCIATES PERMIT NO: - JOB NO: S05-80 AUTHORITY: CITY OF TUKWILA NOTES: TOTAL PROJECT SPRINKLERS = TOTAL SPRINKLERS THIS SHEET 7 FIRE SPRINKLER DIVISION 7855 S 206TH STREET, KENT, WA 98032 PHONE 253-872-7222 FAX 253-872-7277 CONTRACTOR: FOUSHEE PHONE: 425-746-1000 FAX: 425-378-2135 C I SEP - 8 2005 Tukwila Fire DESIGNER: C. GALLANT SCALE: AS NOTED DATE: SEPTEMBER 8, 2005 REVISED / / PLOTTED / FP 1 OF 1 TOKWILA FIRE DElytikrivieNT. Please coli 206-575-4 '07; ard: give this _ Fire Perrnit and exact'addr ss foe. s�ut- h { tat� down or retoga n approval: Hanger Rings / Anchors: UL Listed &. FM Approved Hanger Rods: Comply with NFPA 13 O AU Thread Rods 0. Machine Thread Rods'` Finishes. O Standard Components FlexHead Sprinkler Drop IV-Z!-ZZIO .,;. . Corrugated stainless steel hose with stainless steel braid • available in 2', 3',4',5' & 6' Iegnths Mulls -Port Bracket • • FLE] MEAD Flexheadrtommercial Ceiling Unit T -Bar Ceiling Installation • . Model #2024,2036,2048,2060,2072 25.4 mm • Application / Description .• No: 12 Hangers are designed to support piping under ' smooth or flat concrete slab construction. They utilize an anchor that it set flush in a hole predrilled in the concrete; then expanded against the 'sides of the hole with an internal plug. NFPA 13 terms this type of fastener an ,"expansion shield". In "Automatic's" data, however, the manufac-, turer's nomenclature is used. It is called a drop-in anchor: 'there are 3 components in a basic No. 12 Hanger:: The drop-in anchor, a threaded rod end -an adjustable hanger. ring. The rod may be either all thread rod (ATR) or ma=: •chine thread rod.(MTR). All thread rod is considered to be: standard, however. As a rule, machine thread rod is pro vided only when it it a specific requirement of the job • '. specifications. • • As .an option, the Fanger may be furnished"Wi;h a spring... clip ceiling plate when 3 more finished appearance is needed in an area: NFPA Requirements / Limitations • -NFPA 13 has specific requirements and/or:limitations for the use of expansion shields (drop-in anchors) where they are installed in the vertical position. The standard reads:.:. . /,i conciete having' gravel .or crushed stone 'aggregate; expansion shields 'nay be used to the '. vertical., position tb support pipe 4'" or leis. In die meter ' Por the.support of pipes 5" and larger, expansion shields if used in thevertical position shall alternate with hangers connected directly' to the structural members such es trusses• and girders, or to the sides of concrete beams In the absence of convenient • ' structural members, pipes 5" and 'larger may be sup-.• ported. entirely by expansion shields /n the.Fertrca/ position, tut spaced pot More than ' 10 ft t3 mJ. apart. Expansion shield* shall not be used in ceilings of gypsum or similar softmaterial.. ln, cinder concrete,: expansion shields shall not be used e.'cept on branch• dines where they shall alternate with through bolts of . hangers attached to beams . . Design per NFPA 13, Ordinary Hazard Group All materials to be new, UL. listed, arid F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any. other means All .heads to be at least6' apart • 2 — Add Reliable Model GFR VELO-ECOH Recessed Pendents 165° 3A x3/4 (k factor = 14) • 1=- Relocate Reliable Model GFR VELO-ECOH Recessed Pendents 165° 3/4 x3/4 (k factor =14) • E =Existing no change FIRE PROTECTION INGORPORATEQ:•. ; ..: P.O. BOX 12113 • . • MILL CREEK, • WASiINGTON 98082=0113 Piet._ (42)481-7889, :_:; :•" ; :;. 203 204 206 202 208 021 Mil 1111111 !max 1111111111111 7 DN N Alii" IE� minnum REFLECTED CEILING PLAN. SCALE: 1/8" =1'-0" 0 5' 10' 20' 30' NORTH 0 O1111 H MI III I :s • 210 4) NMS1.___ 1,1,ii 11211 Ohl MEM 1 FIN I Aot II eE 1 oR RIME ilall �l 11111E1M11111011 IISROW 1,111 El WI 1 I 1.........,,J1111111111.L.--111 111111•11111111-10 I 215 ILS 00 )3 Design per NFPA 13, bight Hazard - Offices All materials to be new, U.L. listed, and F.M. approved All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means All heads to be at least 6' apart o 10 —. Add Tyco Model TY5237 Extended Coverage 155° Pendents 3/4 x 3/4 o 6 — Add Tyco Model TY5237 Extended Coverage 155° Pend ents 3/4 x 3/4 (these heads match existing) Clip Hangers ■ Hanger Rings:, UL Listed & FM Approved • Hanger Rods / Fasteners: Comply with NFPA 13 O All Thread Rods 0 Machine Thread Rods ■ Finishes: O Standard Components 0 All Galvanized Cgmponents Components 1. Clip (Ceiling Flange) 2. Hex Nut 3. Wood Screw 4. Hanger Rod 5. Adjustable Hanger Ring Application / Description No. 5 Hangers are designed to support small piping from smooth level wood planking that has a thickness sufficient to receive the required fasteners. The hanger is secured to the planking by means of a clip (ceiling flange or hanger flange) that is provided with a standard thread i r the rod and holes for 2 wood screws. To prevent possibl loosening of the rod due to vibration, the hanger is further secured by a hex nut tightened against the clip. There are 6 components in a basic No. 5 Hanger: The clip, 2 wood screws, a hanger rod and locking hex nut, and an adjustable hanger ring. The rod may be either all thread rod (ATR) or machine thread rod (MTR). All thread rod is considered to be standard, however. As a rule, machine thread rod is provided only when it is a specific require- ment of the job specifications. No. 5 Hangers may alsobe' used with' other types of construction of adequate strength when provided with • suitable fasteners — subject to the approval of the authority having jurisdiction (AHJ). Deviations from standard fas- teners are to be clearly indicated on the plan by detail or in a hanger note (see Hanger Codes / Plan Designations). NFPA Requirements / Limitations NFPA 13 permits the use of 2 screw ceiling flanges only for pipe sizes up to 2" and it calls for the use of screws having dimensions not less than those of No. 18 x 1'/s" wood screws. Drive screws and nails are not acceptable fasteners and wood screws are not to be driven. El Without Comments As Noted in Red i Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau fco- iformance with current City rt? naards. •Accept,:An::.:' k 3ublect to errors and • omissions which do i lc, r;, itnorize violations of adopted i:,:nciards and ordirsasice5. The: responsibility for the Ae quacy of design 1•e. tl,.3 .;;Totzigy with the designer. Additions, deletions i-evlsions to these drawings after this date will void t r ;:c;eptanc and will require a resubmittal of n .visi ,r drawings tri :. • sulasequent approval. Final acceptant E ! .i:Tuble(fir c; st and Inspection by The Tukwila Fire P ',,;.•;<-,•tic, : : Date: i i -1 . -/ CROWN FIRE PROTECTION INCORPORATED P.O. BOX 12113 MILL CREEK, WASHINGTON 98082-0113 PH. (425) 481-7669 TUKWILA 17.18 )E.P,,;Rti 1 MEMT ','C ?i5 -`4O7, and gj e this FIr Peril t Na. /(-s g aiid.exacc aCF u oss. for shut down or.ty!stomUon.approyal. 1NASKINO."ON STXTE CERTIFICATE OF COMPETENCY 1 • FIRE PROTECTION SPRINKLER SYSTEMS • 1 John J. Abet . .. . • 97600591-cG Level 3 i n t=ire Protection, Inc. • •• ; . tura • el , �r1• • 121s1no. Therapeutic Associates FORT DENT III DATE: DRAWN: SCALE; WI.A FINE. 7100 FORT DENT WAYZ2a €a TUKWILA, WASHINGTON 98168 -UI 0 EXISTING T u (2) STORY OFFICE BUILDING AREA OF WORK (± 2,888 SQ, FT) OCCUPANT LOAD CALCULATION 7377,4 51.;17 S JUARf Fr.,C-A• 11..: P•i.fi lr r',:!;•.c:.NTS I,1;,•.1;Fk.rs: PRI:01? FORT DENT PARK ItOM haa alai as EXISTING OFF ICE E 1JlLE)IN FORT DENT III 7100 FORT DENT WAY E, I STING OFFICE BUILDING 1 'PL NTS Mt NMI • Mil PAN Ilat RS RN 444 CO;.=.5.::4 PIC *1 CO l 1 Nle.' -t.,2 Uti ) Djc_ c.)) \-0 E� `-) U.r\cAq.n 1.00 Ec) • \. ` t `\ ` \ ,`\ '\ \, \'\ \ \ \ \ \ \\ \ • t` \ t � SC.w(ik4Yn1 �'.• i "�� ;I t 1 i 1 \, \ ,�.,% ���� ik I mak© `�• \� ,�: ria �T�,_o;, uuu,'1u�111u f�'�."u �0/n1 IUN �� \� -�': � . dei a �. ' � !!!E ,u y -. \ ' • anfill111111111 ' - TIMM WiTrWr I 11.''' -..,,' MI NMI II 1 ;.741N11111......,,311 nommi' mull r 11 4 REFELECTED CEILING PLAN SCALE: 118" = 11-0" 0 5' 10' fr\ 20' • 30' NORTH t 7 • 1 SWi 'YY � b.4::413„G..� p Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The 'Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptar;ce is subject to (store and omissions which do not. ak,khoriZe violation, of adopted .xtandards and ordinances. The responsibilli:y for the adequacy of design rests totally with the designer. Additions, deletions or revisions S to these drawings after this date wiHvoev ised drawingsthis e and will require resubmittal offor sub��eguer approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau, Date: / _"� 1— ( 7 By: TUKWILA FIRE DEPARTMENT Near; r:: Iso "°c5-575-'1 07 and give this Fire Permit No and exact a d'. ,ss for shut- down hutdown or reztorWon approval, SCOPE OF WORK FORT DENT III 7100 FORT DENT WAY TUKWILA, WASHINGTON 98168 TENANT IMPROVEMENT TO THE SOUTH WEST PART OF THE FIRST FLOOR FOR OFFICE USE TO INCLUDE: • DEMOLITION OF PARTITIONS AND DOORS - • -CONSTRUCTION OF PARTITIONS AND DOORS - • • CONSTRUCTION OF CASEWORK • NEW PAINT AND FLOORING IN AREAS OF SUITE • INSTALLATION OF NEV./ AND RELOCATED LIGHT FIXTURES • NO STRUCTURAL WORK • NO ALTERATIONS OF CORE, AREA OF SUITE: ±. 2,886 SQ,FT• AREA OF FLOOR: ± 20,C ti SCS. FT. OCCUPANCY TYPE: B, OFFICE CONSTRUCTION TYPE: V -B, SPRINKLERED APPLICABLE CODES: 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 NATIONAL E_EC1 RICAI. CODE ICC/ANSI 117,1 • ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2015 WASHINGTON STATE ENERGY CODE (WSEC). WAC 51-11 WASHINGTON INDOOR AIR QUALITY CODE ASSESSOR'S PARCEL 11; 29549M440 I1 p1y"°°M4p +r r "Y ....... m C�P26IF GA E O�afd Sjq'y"`+,w w,,,n �'. W FIRS FRC1g�CT10N SPRINKLER a ErENCY A Lewis azaNatLca srsrE� a At +� I'�:rers g 2800.0691"C Level3 it1 a First ere ease Fire Protection, L. L. C. Fife$ ' FCJe. - - a It sari mum ciao% un en At W a Ri i ase 4 i3 xry�rrsk I--30._ e -� P PAID JAN 30 2017 -WWI FIRE cc $3ot)' FIRST DEFENSE FIRE PROTECTION LSC SPRINKLERS BEAT FIREMEN TO THE BLAZE 10212 215th AVE SE SNOHOMISH, WA 98290 PROJECT ADDRESS vz_c u (c, SCALE NOTED CITY TITLE FIRE SPRINKLER PLAN PHONE (360) 794-9479 LIC# 602-250-698 DWG # MECHANICAL, PLUMBING, FIRE PROTECTION & LIFE SAFETY NOTES NTS 6 VICINITY MAP NA SITE PLAN NA 7::\E-1)( I I MFG. ESC. MODEL FINISH ORIFICE ��••.�_�SPRINKLER (`'tc x ri-L L,-,` ' - :IS ., t It ` :,' •l{, 5�� -- .,:Java 1 •+`t • ✓' --_.-- ____ —_—_ t_..., ..,, :;fit; �R p�y�.y ...: ; . - i. '+t:'S': '} :'. ���� _ _ Til` 2• >/,Y,:Y9 fir::R ..5,, %: , ;ri= : ", •y' ::±�. �..'; •.,�'2z:'�i'�.J' .1+ ,� :� �4y %%/{, `}i✓;i tri f'' ";{;:Y fif.,i..;✓f ,•,.• .�'y: �' n,o•`::ky5�?� 4y13 SY`Y^+ r`. r:r'ri'}=,'r.•'�r.:6`'•'r�'ri,. �v:;.;:.„'.>,:1;2.- :.•.;.:..,�^:...<Yi:'/.rr'y;'v'.rs. ' ir — ?,.! .•,EX'Js•`3�G,:. !?' fr :,Sri fr�,i: �.c� e;:'n+St. ryi'" ,', pj�.'.;Ji'a''.'/ r`� / ` `-5 r� ?...Yn( .;r`,•,-;ftY3':Y .`•y f;' . f7%'%4 ' •;..%a ,cr,.t.J t' jT •l..:u{ 4: ,<+' }..�, �, + � �"j,�,1'c`'t'4�;3)s;'�; J rY,:� ,/, .i:�.+ :<V ;i;'s � � % g"f'.'�; �7 r"`"'�v:S+r r ,^,;::';>,i�l>�y: )'.C' 3x, y.5„ J:'L,:r;.iQ:::.t.. �,� fyjs.>.r,�;f!N %`'. "r��°`'rrf5, r `%i; / f'= 5''"7!/'.•''•'. Y,'', 1."<;n'r,`'r.'<l: . _._ _ N---_ -- ,./ • {'- v sftl �•' /s. q4; -l+J/ •; i' rg %".�: •jUw is •',':'fix1 II _.... } • £.f�•;:l�:.3't���Wc,Yny.�•';:. �T,'.•i�,.CyG'•6 �'�J<4n63++4tirST;�YfI ''` "v',✓,/%/'p ?:x> p2r,•IN /.,.",i?))':'-- fr 1; •/i iftgyY' '. +%a: f�y.,-C•';s'nL;.V.A'�Ui,-.EP{{��.,• v y/ f ` '<k 'f f~!, ; i^% % S �.'{,m`+ yy J s{'%."..''' , .:t 1h�+�: 'vii r'>r d' ; <;%,'•l.,L.•+•,r.. 3�✓.- %•,/i' i.�yy �� 'dj N S;j, ''' \ /,{r' f `;.� • 1 ���y �'::,• !' y+r J;y'. '•Ai,_',.:5• , ?''Gr'.'.,ys fi�'fii',si-•,.,• .i<'Sj% j./r1. y.5'•' �J/!!'• iir;.a.r'' _ 1,.,',...111110011.11,.,gym io ,wxcaa7g+�,%s: J,,.�/% .; <. 11111111111111111101�� C` �L`�e �S 150 •r REFLECTED CEILING PLAN SCALE: 1 /8" =1'-0" 0 1�= tZ�loGnT�. 5' 10' 20' 30' HEAD COUNT TYPE K. MFG. ESC. MODEL FINISH ORIFICE ��••.�_�SPRINKLER (`'tc x ri-L L,-,` ' - :IS ., ,tTOTAL SPRINKLERS THIS DRAWING NORTH 2 4;; © Without Comments As Noted in Red Per The Attached Letter These pians have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not aI.rthorize violations of adopted :a'ndards and ordinance The responsibility for the -,dequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance 15 subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /) -I> -r ) By. c(1 TLF CI SQA FERE DEPARTMENT Please �•: fiJ ° :r -5M-4 :07 and Ow, this F; ar Permit No. /-7 _ S- _ (7�nd exact address for shut- down hutdown or restorOn approval. SCOPE OF WORK: TENANT IMPROVEMENT TO SUITE 225 OF AN EXISTING 2 -STORY OFFICE BUILDING FOR OFFICE USE TO INCLUDE • DEMOLITION OF INTERIOR PARTITIONS, DOOR & RELITE • CONSTRUCTION OF INTERIOR PARTITIONS, DOORS, RELITES & CASEWORK • NEW PAINT AND FLOORING IN AREAS OF SUITE • INSTALLATION OF RELOCATED LIGHT FIXTURES SITE ADDRESS: PARCEL NUMBER: LEGAL DESCRIPTION: ZONING: FORT DENT III 7100 FORT DENT WAY, SUITE 225, TUKWILA, WA 98188 295490-0440 GUNDRAKERS INTERURBAN ADD PARCEL 2 LESS GEG MOST WLY CORNER OF PARCEL 1 TH N 63-35-49 E 237.32 FT TH S 26-24-11 E 227.32 FT TO COMMON COR BTW PARCELS 1 & 2 TH N 63-35-49 E 252.25 FT TH N 26-24-11 W 77.65 FT TH N 56-15-11 W 234.09 FT TH N 31-12-43 W 82.39 FT TO INTSN WITH NWLY LN OF PARCEL 2 TH S 58-47-17 E 102.77 FT TH S 55-39-53 W 63.16 FT TH S 48-39-58 W 55.63 FT TH S 39-21-15 W 88.24 FT TH S 30-04-58 W 85.21 FT TO MOST WLY COR OF PARCEL 2 TH S 37-36-40 E 20.92 FT TO POB - OF CITY OF TUKWILA SHORT PLAT NO 79 -7 -SS RECORDING NO 7908210370 SD SHORT PLAT BEING A POR OF GUNDAKERS INTERURBAN ADD IN SW 1/4 OF SEC 24-23-04 --- AS PER CITY OF TUKWILA BDRY LINE ADJ NO 90-2-BLA RECORDING NO 9008151101 PLAT BLOCK: PLAT LOT: POR RCM TYPE OF CONSTRUCTION: V -B, FUL' Y SPRINKL ERED- OCCUPANCY: GROUP B (OFFICE) AREA OF FLOOR (SUITE): ± 1,938 SF APPLICABLE CODES: TENANT BUILDING REPRESENTATIVE: ARCHITECT: WASHINGTON STATE CERTIFICATE OP COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL PLUMBING CODE (IPC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 WASHINGTON STATE ENERGY CODE (WSEC) 2015 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2014 NATIONAL ELECTRICAL CODE (NEC) 2009 ICC / ANSI A117.1 - ACCESSIBLE AND USABLE BUILDINGS & FACILITIES WASHINGTON INDOOR AIR QUALITY CODE WOOD-RICHARDSON & CO., P.S. 7100 FORT DENT WAY, SUITE 280, TUKWILA, WA 98188 PHONE: (206) 246-2520 EMAIL: SHARI@WRC-CPA.COM CONTACT: SHARI WOOD-RICHARDSON & STEFAN RICHARDSON JCR DEVELOPMENT COMPANY 2835 82ND AVENUE SE, SUITE S1, MERCER ISLAND, WA 98040 PHONE: (206) 267-6060 EMAIL: RebeccaDavidson@jcrdevco.com CONTACT: REBECCA DAVIDSON NELSON 1200 5TH AVENUE, SUITE 1300, SEATTLE, WA 98101 PHONE: (206) 408-8500 EMAIL: MEvans@nelsononline.com CONTACTS: MARK EVANS PLAN NORTH SCALE FIRST DEFENSE FIRE SPRINKLERS BEAT FIREME 10212 215th AVE SE SNOHOMISH, WA 98290 PROJECT h Wf^ j i�w(! y pr,gZ c ADDRESS / 1 -b -1- CITY .-TU �--�-�a t. t/, 186 TITLE .. FIRE SPINKLER PLAN III 1Naa .and AVS} NOV 2.3 2017 TUKWILA FIRE cc 3'' R O TECTION LLC TO THE BLAZE PHONE (360) 791-9479 LIC{/ 602-250-698 BYAY11,1 Lr' l CAD FILE DWG fl FP -1 Ntfr IN CANTiq_kG"\-- ;JEW fro -z. g.6m6ve- r Og.op 71 Zi. ---)4151' WAD kee-A-rrokl 54(1sT 014.4E04-LIJE AAM -ovr1.1z- (.5 e -e. RAO) c81.-.5° epiLikiG iz.&4_0c.,4 Tao PEW, 14 -EAP 1Yr Owe, 4P -A -D _ - • 11 i` • • • • -• r. i/ _;•••-11 (-1". - " I 4 t -S" ° 34-Sni t S11 • , 1 hit —0-7.1 ..72'6•XlSTA • • N Or IN Colo -MALT itt.•••••• ••••••••11: 1) • TT L. . goTAT5 131KANickk GIMC- {80° . - - • • 22. .11\ r -)Ls -r• • .tte 1,4" 22 0" 7740 ROTPriE. /..1i9 ibo° .},10T 1.1 NV -10 C,o10-t-RAcr Nor IN Cow c -r It - 3. )1' NUT IN GAM. 1A(.7. Li NOT _ cototm-r _ _ ..11•1 Ct>NTRIbt-c..7 NOT Cb1.11-RACT 4—i," TRU `434._A-41;0602 1,1 21..511 311mAto gOOF "C„Ic 11 DETAIL- A s. 91- Q AFF ---e ye.= FLODR FIRS 5P_R_INKLER D_Arls NoR1-4-1 kfiftc 3 /1••••••1. .1••0 Nalmmtacedat• ••••••• 18 2111 To 7-0P or- Pt ek. 4 ic 1C -s" 130r. OF gi Uj Toe klcir h3 Ce. KIT KlAc,1- RAT n ;R0,1-41". LIN V.X‘ST1 NG HEADS 27C) .1.. . 0-8,-- • sTuPY room. Al . gl C*4 _•- 'NI 0 /Imo la : -; ciir.,-.- .....-- 1 -S-Tt-IDY RotA, 1 —A 7=-7'422-4- = lV0C.IME7 2" ---- ..- - • C--.41 Tr.! cc's" 1 o-74--1/1. A 711 11 \jpcjKaat S otommosomarturrott. GCNCRAL. No-rz5 -a/ ALLEXIsTING ite-AbS 0 L -co 'RGL I AEI -G. MOD. )(I-0 ci..,ebtAg R.ec...essgr). MAX. SFC -t, IS IV )4-1 to I. - - MINIMUM 'A( -l1-3' 'etirvicEt.) SP12101cLeR HEADS 1 S IS: FeET; e..X1ST It 1(7 "...z.i4:113r.A-s-k Ys Ill IS DeSI‘Net:. fik TDeVIS ITY OP; _ ttS PitA Okit-31 !i•("0 SCIOW F•• eT. 1.)5 .1-1410,..L'R S., 10 3/g" v.)? AA C.I--rk IA? OM' :re la 01) I I (t2z---77i 6111:A -P) CD AUL /•.1v-/ . PIP/OC--:7 -r' FIP1V41 15 0 li-Cag'L Al3DVE FM)1511-- FLCOR • *I -1 = ,4„ Io ' ILII1/ 0 it VOCI RoOtA7 6 HEAD Coo t,,,rr war -eA e, IS1/5-vo SYm, OA l'Pr 100 ADD :NEW R ELI ABLq MOD. G LD EGON CMR.olvIG t--Ncv -rQ7?k-r—, 77141 Pt-A,c.J. 1111111,010103111110.er .E.XISTIOG CEILING GR,I'D AT 0 omments A Note In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not -authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletio isions to these drawings after ptance and will require a resubmittal of rev i ings forsubsequent approval. Final acceptance is subject to field test and inspection by ;The Tukwila Fire Prevention Bureau. Date:7/7-4/9 By: TUKWILA FIRE DEPAri fiN1 Please call: 575-4407 and give this job No. and exact address for shut. down or restoration approval. r AH 6K CONSTRocrio0 INC . 7855 So. 7.0 TH ST Kw,rr, WA , Cf032- .............. Pttope. -;f. 53- 872 P;72 - 9177 SCALE: y 1 0 DATE : j1,) L 9 APPROVED BY: C.-ITY or- TOicut..44 DRAWN BY self,,E,-1-T REVISED UN)11MR SIT NI OE VI-10etsitA `j !OD FtigT Dr. -11" Wy TO•Kwit..14, wA. 1818R 59q- 6`1 211' F 'FIRE sPRtwsLeR131-AoS DRAWING NUMBER i oF � :••..,C^.�c11Y3Li.]_'S..'.tLCltrtt[i.13i.C1Y2CtlM.slyluCA. e.a."ammwa (B) 8 f 1 1 comm 1 =mu 1 ummell AREA OF WORK 0111110101 I 1101010 1 01111101 I 1101011101 I ==1111 I 1=10011 1 0=1 I 0011=11 I 11111112111 I 01=101 I 10111=1 I 00011 I I 11101801 1 110000101 I I =MEI I 111110001 1 I - NEW MAIN RUNNER 1 WM= I 1111=1011 1 01=0011 I 4'- 1 2x MECH TEE EXISTING WALL NEW B/S CEILING GRID & TILE. NOT IN CONTRACT FL TUKWILA FIRE DEPARTMENT Please call: 575.4407 and give this job No. C) Z S and exact address for shut, clown or restoration approval. nVdA IPA11 Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire ; .'Tevention Bureau for conformance with current city andards. Acceptance is subject to errors and . omissions which do not authorize violations of adopted • standards and ordinances. The responsibility for the aquf drests With . Additionsdeacy , odeletionsesign or revisionstataily to thesethe drawingsdesignerafter ' this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by ,11,1e Tukwila Fire Prevention Bureau. I bi �5 (t 2 By: 1 Date: '� c�alJ � —S 1a F -tl TBE EXISTING GIRDER I. EXISTING 2" BRANCH LIN 9 N.I.C. 1 ;1-MECH 2171- 4-OTB4 j 1 EXISTING 14_ EXISTING LIN AREA OF WORK 2AT _.. 2-0 _... xZ.3 1 ■jj' APEZ 4-6 1-OTBE c7 0I PI(~/) )IV) XIO - XIO W W I 111=011 I I I I 0 F=IN PIw xl� >< W W — -2x7-3 TRAPEZ 0 0 0 0 z)- z1- z)- NI� -, I-) ,NIT WI WI WI I i=1 1 CM= 1 =100 1 OEMS I i1 0 z ,— w WI ® I 00101011 C7 C� 0 Z ►— z r— z 1- to 1= V) T= N Ln v) cnlo N wI 0 cel LA SIV . 1.=N. v V)10 NIO —3 X X WI WI \ I 1110101 1 101010100. MIES 1 r"""."1 1 MEM I =MI I MN= I NOT CONTRACT EXISTING ELEVATOR LOBBY 2" BRANCH LINE I _ EXISTING GIRDER U1STINL. rBRANCH 2 BRANCH LINEI OPEN TO BELOW EXISTING EXISTING EXISTING GIRDER 2" BRANCH LINE I 2ND FLOOR PARTIAL PIPING PLAN SCALE 1/8" = 1'-0" E 0 EXISTING PENDENT LOCATION 4 P 0 PLUG EXISTING PENDENT HEAD ' 36 R ® RELOCATE EXISTING PENDENT HEAD 13 A ® ADD NEW PENDENT (RELIABLE MOD. G., XLO-ECOH RECESSED CHROME PENDENT, 3/4", 165') (49) TOTAL RELOCATED & ADDED HEADS 8) FOLDIN 1 ==a 1 = 1 mom 1 eanso 1 row mum 1 ism 1 sumo 1 mom I NOTES: 1. ALL HANGERS & PIPING TO BE INSTALLED PER NFPA 13. 2. ARMOVERS OVER ' -0 TO UPPORTED PER NFPA 13. 3. LOCATE HEADS 1-0 x 1-0 IN SUSP. CEILING TILES. 4. ALL EXISTING' PENDENT HEADS ON SECOND FLOOR ARE RELIABLE MOD 'G' XLO—ECOH 3/4" CHROME RECESSED. (MAX SPACING 16'x16') 5. ALL NEW SPRINKLER HEADS .TO MATCH EXISTING. 6. EXISTING SPRINKLER SYSTEM IS DESIGNED TO A DENSITY OF .15 GPM OVER 1500 SOFT. 7. HANGERS FOR'!:ARMOVERS TO BE 3/8" C—CLAMP W/ RETAINING STRA", ROD & RING. UNLESS OTHERWISE NOTED. 8. ALL NEW PIPING TO BE BLT. 9. ALL PIPE CUT.- DIMENSIONS ARE TOE UNLESS OTHERWISE NOTED. PARTITION NEW MAIN 225 RUNNER MB I 0011= I 0 16) 4'-O" 1111=11=II I 1110109181 I MIES I I • irmamodi --..- 1 p 1 ABBREVIATION HANGERS REVISICNS SPRINKLER SYMBOLS AFF = ABOVE FINISH FLOOR A.S. = AUTOMATIC SPRINKLER BOD = BOTTOM OF DECK BOP = BOTTOM OF PURLIN CC = CENTER TO CENTER EC = END TO CENTER TOS = TOP OF STEEL O = HYDRALIC NODE POINT #1 - "t' LTI" W10 POWDER ACTUATED FASTENER, f D COUP., ROD & RING #2 - C CLAMP, RETAINER STRAP, ROD Sc RING #3 - VI LL BRACKET, ROD & RING #4 - 'LING FLANGE, ROD & RING #5 - DATE DESCR1PT.'ON BY * * * TOTAL SPRINKLERS ARCHER CONSTRUCTION 7855 SOUTH 206TH STREET KENT, WA 98032 PH. (253) 872-7222 FAX. ::.(253) 872-727.7 STAT- FARM 7100 FORT DENT WAY TUKWILA, WA 98188 _CONTRACTOR: .FO.USHE ...ram OCT 22 2002 35 SPRINKLER PI 'ING PLAN PERMIT NO. CONTRACT NO. _02-70 APPROVAL CITY OF 1 UKWILA C.D.T. B. IOFFER SCALE 1/8" 1'-0" DATE 1016/02 REVISED PLOTTED FP1(f1 I , ; • NOTE: EXIST CEILINGS ARE 8'-5" SUSPENDED CEILINGS WITH TEGULAR TILE. EXISTING PIPE IS APPROXIMATELY 18" ABOVE THE CEILINGS. IT IS APPROX 37" FROM CEILINGS TO BOTTOM OF STEEL BAR JOISTS. IT IS APPROX 57" FROM CEILINGS TO BOTTOM OF CONCRETE DECK ABOVE. EXISTING rr:t.ING GRD SYSTEM r0 REMAIN / FW'' / , +fir l / / Min -1'1'17F f- / / / • , , 12i1� % `// // / // / / / / R_ RR E. E • 1 1-8 L. R E /' _ /1L/.. /0/ E / Q av 00 0 JAN /OR —7 0 4" WET SPRINKLER RISER 155 PSI ON GAUGE„_ L 23 1-2 R E O IIIHilIH ui E EX!r111\10 i 11R, RAI El.) (1:(E?R IIJ(•:{Il is NO WORK 115 n 11 u1 A • E p� —J>�1 lr8�-� -- —11.-%_ I�1:3� r 3-10 n 11 No WORK • NORTH ITU 1;;; f ,a 1..i1 i?i 1 SCOPE OF WORK: 1. ADD & RELOCATE REQUIRED SPRINKLERS FOR NEW WALL LOCATIONS. 2. EXIST HEADS ARE STANDARD RESPONSE & NEW HEADS WILL MATCH (NON "QR"). 3. WET SYSTEMS TO BE DESIGNED PER 1-1FPA #13 ORDINARY HAZARD. 4. PLAN SUBMITTAL TO AND APPROVAL BY CITY OF TUKWILA: 5. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY ARCHER CONSTRUCTION. • CLARIFICATIONS: 1. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED AT A MINIMUM OF 40°F (BY OTHERS) IN ORDER TO PREVENT THE PIPE FROM FREEZING. EXCLUSIONS: 1. TAXES & ELECTRICAL OF ANY TYPE. 2. HEADS IN CENTER -LINE OF CEILING TILES (EXIST ARE NOT). 3. STRUCTURAL VERIFICATION AND ABATEMENT OF ANY TYPE. 4. RELOCATION OF EXISTING PIPE FOR NEW WORK OF OTHER TRADES. FITTER NOTES: 1 HANGERS: *ALC PIPE HANGERS TO BE HILTI HDI -P OR A TOP BM CLAMP & RETAINING STRAP. 2. MAXIMUM HEAD SPACING TO BE 256 SQ. FT. 3. ALL THREADED PIPING TO BE ALLIED XL JOINED W/ THREADED FITTINGS AND COUPLINGS. r: Xt $11.130.1:'1:-1.(f 1( SY1316I I ,') E EUtITlC;r11_. • E; :15111',!(. 1 HR. 10,1!'..l.) C('. FU 10 F;f:fil/,lN UNALTERED wJ • 0 CE 1- ; � �:�� \ \ \\ FORT DENT III 7100 FORT DENT WAY EXISTING OFFICE BUILDING FORT DENT III 7100 FORT DENT WAY EXISTING OFFICE BUILDING LATC 1-4E tjrka_ TELL 1ST FLOOR REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0" 0 2 4 8 16 -SCALE IN FEET ALL C.r0i)iC,'). FIT 1'_ i-\L_CC 5 1 ��l�C ._CL.14 Liu RLAL'.l-C. VLX 1 onC Li -k PAIL. . 1 tD)'\ \� ‘1.1) LLr E , i e_c) L} t = (tJ 1 77,51 ik 7_1 -�—�... Wit. i 4• •`�- .yam Te t c n `Without tOniments C]Ps Noted in Red Per the Attached Letter These pians.have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do rot authorize violations of adopted standards and .ordinances, The responsibility for the adequacy of deSign r�: ,t totally with the designer. Additions, deletion :; �F:visiorls to these drawings after this date will void this +-~r:eptance and will require a 4resubmittai of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: 5-- �-i - c By: .J "` St TUKWILA FIRS DEPARTMENT Please call 206-575-407 and give this Fire Permit Noe and exact address for she down or rem approvj9 v SCOPE OF WORK: SITE ADDRESS: PARCEL NUMBER: LEGAL DESCRIPTION: ZONING: rD 9NIG1If19 III INDa 1210d TENANT IMPROVEMENT TO THE SOUTHEAST PORTION OF THE FIRS' FLOOR FOR OFFICE USE TO INCLUDE: • DEMOLITION OF PARTITIONS AND DOORS • CONSTRUCTION OF PARTITIONS AND DOORS • CONSTRUCTION OF CASEWORK • NEW PAINT AND FLOORING IN SUITE • INSTALLATION OF NEW AND RELOCATED LIGHT FIXTURES • NO STRUCTURAL WORK NO ALTERATION OF CORE 7100 FORT DENT WAY TUKWILA, WA 98168 295490-0440 GUNDRAKERS INTERURBAN ADD PARCEL 2 LESS GEG MOST WLY CORNER OF PARCEL 1 TH N 63-35-49 E 237.32FT TH S 26-24-11 E 227.32FT TO COMMON COR BTW PARCELS 1 & 2 TH N 63-35-49 E 252.25 FT TH N 26-24-11 W 77.65 FT TH N 56-15-11 W 234.09 FT TH N 31-12-43 W 82.39 FT TO INTSN WITH NWLY LN OF PARCEL 2 TH S 58-47-17 E 102,77 FT TH S 55-39-53 W 63.16 FT TH S 48-39-58 W 55.63 FT TH S 39-21-15 W 88.24 FT TH S 30-04-58 W 85.21 FT TO MOST WLY COR OF PARCEL 2 TH S 37-36-40 E 20.92 FT TO POB - OF CITY OF TUKWILA SHORT PLAT NO 79 -7 -SS RECORDING NO 7908210370 SD SHORT PLAT BEING A POR OF GUNDAKERS INTERURBAN ADD IN SW 1/4 OF SEC 24-23-04 - AS PER CITY OF TUKWILA BDRY LINE ADJ NO 90-2-BLA RECORDING NO 9008151101 RCM CONSTRUCTION TYPE: V -B, SPRINKLERED OCCU PANCY: AREA OF SUITE: AREA OF FLOOR: APPLICABLE CODES: TENANT: BUILDING REPRESENTATIVE: ARCHITECT: CONTRACTOR: GROUP B (OFFICE) ± 2,979 SF ± 20,066 SF 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL PLUMBING CODE (IPC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 WASHINGTON STATE ENERGY CODE (WSEC) 2015 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2014 NATIONAL ELECTRICAL CODE (NEC) 2009 ICC / ANSI A117.1 - ACCESSIBLE AND USABLE BUILDINGS & FACILITIES WASHINGTON INDOOR AIR QUALITY CODE FUSE NETWORKS 1ST FLOOR, SUITE 140 7100 FORT DENT WAY TUKWILA, WA 98168 JOHN C RADOVICH DEVELOPMENT 2835 82ND AVENUE SE MERCER ISLAND, WA 98040 PHONE: (206) 267-2669 E-MAIL: REBECCADAVIDSON@JCRDEVCO.COM CONTACT: REBECCA DAVIDSON NELSON 1200 5TH AVENUE, SUITE 1300 SEATTLE, WA 98101 PHONE: (206) 408-8518 E-MAIL: LDUCEY@NELSONONLINE.COM CONTACT: LINDA DUCEY TBD O®.W.oe�tameern.rre.,e.rae,.m116019 r% 0 WASHINGTON STATE CERTIFICATE OF COQ FIR! PROTECTION SPRINKLER SYSTEME Lewis Potent 2800.0691•C Level First Defense Firs Protection, L.L.C. FIRSTDFNIRP beeeessesas Was rrti� c" -s. FIRST DEFENSE FIRE PROTECTION 10212 215TH AVE SE SNOHOMISH, 8'A 98290 P 380-794-9479 PND At -- 3 2 TUI,. IILAFIRE cC/3/-2' PUS N\ wO s \jj-k-A \"41i fl‘ () -Cs?) FIR'•T FLOOR DATE 02/1/18 SCALE AS NOTED DRAWN JOB NO. 17-078 DWG. NO. • 2 MECHANICAL, PLUMBING, FIRE PROTECTION & LIFE SAFETY NOTES NTS FORT DENT PARK GPEEN RIVER FORT DENT 111 7100 FORT DENT WAY EXISTING OFFICE BUILDING z 1N��RS� PTE �p5 NORTH VICINITY MAP NA SITE PLAN NA iendadde uormalsA Jo UMOP -Inqs v SS) zilluod ,A55 rue LCF7':'-5fS� ,1.(` g21WiliVd2 Aq uol adsul pue prip 12UEJ 1en0adcl lua!lha`.:igri ;Y 12)41wgnsaJ C? aiinhaa ;ilt,', pie illrh a:y'p Jaw S6U!MWP 7sail:l U1 S !0rni, = :t.)i' is 'suoplppV •JauSFsap al.I) (pm AlleaO;..._ ..> ,,;i ii=�� 10 Aapnbape aq1,16.4 701IIClsuodsa., 0111.•:,:j0,_.:.UI1.>.,0 i).. ; spaepuels pagdope 40 suoi4el0iA azpo.4;u si.' .,.r .: ; : ?.toigiv' Su0l.Ss1UJO pue siona pacgns rst ;:r. u2:Ida)DH •spaepums AlIO lua un0 itwo aDuewio4uo3 .!OJ neaang u0l uaAaad aal� ellM)nl all Aq paMalnaa uaaq anal sueld asayi as al PUD 2 V LII Jed pad uI paION St, sS,uawwo3 4not.pM 3 DI EXISTING TENANT SUITE flax. 14F m: L uS � PEA E ? I� /. 1„L �` ��� Lac_ tom,Pk...0 Nt r\ 1 .�5`C .tet; c S NN ik_4__) EXPANSION AREA REFLECTED CEILING PLAN' SCALE: 1/8" =1'-0" 0 5' 10' 20' 30' 2111. N 1'A \? .Y 'HA? — co M. oo -v - R- X12 Ls—, lam. �`/� C \rr P 1 1 T Ar CT` \iL YZ ,S r-15 r1 \A_ Ur {`" A\@. ,. NORTH --{ J Ci` O 7 3� m rn c- rn� cn rn rn O NIVINf1O1A1 NJJID Ja'flMN III lNJG fIOd SCOPE OF WORK: TENANT IMPROVEMENT TO EXPAND E)i ISTING SUITE OF AN EXISTING 2 -STORY OFFICE BUILDING FOR OFFICE USE TO NCLUDE: • DEMOLITION OF INTERIOR PARTITIO S, DOOR & RELITE • CONSTRUCTION OF INTERIOR PARTI-`IONS, DOORS, RELITES & CASEWORK • NEW PAINT AND FLOORING IN AREAS OF SUITE • INSTALLATION OF RELOCATED LIGHT FIXTURES SITE ADDRESS: FORT DENT III 7100 FORT DENT WAY, SUITE 150, TUKWILA, WA 98168 PARCEL NUMBER: 295490-0440 LEGAL DESCRIPTION: GUNDRAKERS INTERURBAN ADD PAR EL 2 LESS GEG MOST WLY CORNER OF PARCEL ' TH N 63-35-49 E 237.32 FT TH S 26-24-11 E 227.32 FT TO COMMON COR BTW PARCELS 1 & 2 TH N 63-35-49 E 25 .25 FT TH N 26-24-11 W 77.65 FT TH N 56-15-11 W 234.09 FT TH N 31-12-43 W 8 .39 FT TO INTSN WITH NWLY LN OF PARCEL 2 TH S 58-47-17 E 102.77 FT TH S 55-39-53 W 63.16 FT TH S 48-39-58 W 55.63 FT TH S 39-21-15 W 88.24 FT TH S 0-04-58 W 85.21 FT TO MOST WLY COR OF PARCEL 2 TH 8 37-36-40 E 20.92 FT TO OB - OF CITY OF TUKWILA SHORT PLAT NO 79 -7 -SS RECORDING NO 790821037 SD SHORT PLAT BEING A POR OF GUNDAKERS INTERURBAN ADD IN SW /4 OF SEC 24-23-04 --- AS PER CITY OF TUKWILA BDRY LINE ADJ NO 90-2-BLA ECORDING NO 9008151101 ZONING: RCM TYPE OF CONSTRUCTION: V -B, FULLY SPRINKLERED OCCUPANCY: AREA OF SUITE: AREA OF WORK: APPLICABLE CODES: TENANT BUILDING REPRESENTATIVE: ARCHITECT: GENERAL CONTRACTOR: PLAN NORTH SCALE 1/43=1-0" GROUP B (OFFICE) ± 2,886 SF ± 726 SF 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL MECHANICAL CO 2015 WASHINGTON STATE ENERGY CO 2015 INTERNATIONAL FUEL AND GAS C 2014 NATIONAL ELECTRICAL CODE (NE 2009 ICC / ANSI A117.1- ACCESSIBLE Al WASHINGTON INDOOR AIR QUALITY CC KEURIG GREEN MOUNTAIN 7100 FORT DENT WAY, SUITE 160, TUKWILA, WA 98168 PHONE: NA EMAIL: Marc.Bard.@gmcr.com CONTACT: MARC BARD IBC) (IPC) )E (IMC) )E (WSEC) )DE (IFGC) 3) ID USABLE BUILDINGS & FACILITIES DE JCR DEVELOPMENT COMPANY 2835 82ND AVENUE SE, SUITE S1, MERCER ISLAND, WA 98040 PHONE: (206) 267-6060 EMAIL: RebeccaDavidson@jcrdevco.com! CONTACT: REBECCA DAVIDSON NELSON 1200 5TH AVENUE, SUITE 1300, SEATTLE, WA 98101 PHONE: (206) 408-8500 EMAIL: MEvans@nelsononline.com CONTACT: MARK EVANS DP INCORORATED 19936 BALLINGER WAY NE, SEATTLE, WA 98155 PHONE: (206) 361-2989 EMAIL: vshadrin@dpi.com CONTACT: VASILY SHADRIN WASHINGTON STATE CERTIFICATE OF COMPETENcy FIRE PROTECTION SPRINKLER SYSTEMS CsTeA PAID JAN 26 2fl1,' TUKWILA FIRE ec /2-00— SM- FIRST DEFENSE FIR7 PROTECTION LLC SPRINKLERS BEAT FIREMEN TO THE BLAZE 10212 215th AVE SE PHONE (360} 794-9475 SNOHOfISH, WA 98290 PROJECT % GREEN ry i i -I ADDRESS J \OO' wA SU, E 1, (,0 CITY t. J IA f 1 t \ c st 6 1< TITLE LIC/ 602-250-698 BRAWN LP FIRE SPRINKLER PLAN DDT CAD FILE DWG H SITE MAP SCALE: V-0"=801-0" • Fr.+ Trra ors( :trys t CI Without Comments ID As Noted in Red )Er Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance With current City 5t.widards. Acceptance is subject to errors and offlissions which do not authorize violations of adopted standards and ordinances. The responsibility, for the baequacy of design rests totally with the desjgner. Additions, deletions (.,!' evisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequegt approval. Final acceptance Is subject to fleld test and Inspection by The Tukwila Fire Prevention Bureau. Date: 1 -M By: 1 Fire Permit Number To schedule inspections call 206-575-4407 FORT DENT III BUILDING 7100 FORT DENT VAY, TUKWILA, WA 98188 FORT DEN PARK .1-rEcks-ci""- A's LOCATION MAP AN-Oi NOT TO SCALE • ...... • _ • (13 PROJECT TRUE NORTH NORTH rauiii 111.11 , 1.1 •'.. V, • . Vs, .. y, 10,41,'.... "1.;111(,4,,,—, • . : ''''':: .11111.111 i•I 104 1 INIIINKM, 105 1 II riIII1I 107,1111110•111 -1•11-11111111ramarica IMM Eli ACT r- - 111111n011MITMOlowziN101111110_1_12L • 1.0111111111111 Ism. 1111.: Joximo•111111111111111 111.-,1L--11111—. • • 101 102 mai IN NMI UMW REFLECTED CEILING PLAN SCALE:1/8" = 11-0" ••••(I*IIMEID CJ — 0 LO C) CDUU- (3 \ 5-•-• . • t1.1 • 0 / Ho ci A o 0 SCALE: 1/8" = 16' C tAr- tx,/ ........ maioeireemmeemeposowers1 seampicalvassimmiTs or STATI owrinumey MI mammies aressuast SWUM 1 11 11 Lewis Peters1 2800-0691-C Level 3 First Defense Fire Pretectbn, LLC FIRSTD1i,“ 1:11W ira mem Gomm 121311111 eincerou ..... meow esmetudil BUILDING INFORMATION SITE ADDRESS: PARCEL NUMBER: LEGAL DESCRIPTION: ZONING: BUILDIN DESCRIPTION: YEAR BUILT: CONSTRUCTION TYPE: FIRE PROTECTION: NUMBER OF STORIES BUILDING TOTAL FLOOR AREA: revisions client . ....... • . , — . ••• • .„ JCR DEVELOPMENT 2835 82ND AVE. SE SUITE S-1 MERCER ISLAND, WA 98040 TABOR 100 TENANT IMPROVEMENT 7100 FORT DENT WAY, SUITE 100 TUKWILA, WA 98168 project name & address REFLECTED CEILING PLAN sheet title 7100 FORT DENT WAY, TUKWILA, WA 98168 295490-0440 GUNDRAKERS INTERURBAN ADD PARCEL 2 LESS BEG MOST WLY CORNER OF PARCEL 1 Th. N 63-35-49 E 237.32 FT TH S 26-24-11 E 227.32 FT TO COMMON COR BTW PARCELS 1 & 2 TH N 63-35-49 E 252.25 FT TH N 26-24-11 W 77.65 FT TH N 56-15-11 W 234.09 FT TH N 31-12-43 W 82.39 FT TO INTSN WITH NWLY LN OF PARCEL 2 TH S 58-47-17 E 102.77 FT TH S 55-39-53 W 63.16 FT TH S 48-39-58 W 55.63 FT TH S 39-21-15 W 88.24 FT TH S 30-04-58 W 85.21 FT TO MOST WLY COR OF PARCEL 2 TH S 37-36-40 E 20.92 FT TO POB - OF CITY OF TUKWILA SHORT PLAT NO 79 -7 -SS RECORDING NO 7908210370 SD SHORT PLAT BEING A POR OF GUNDAKERS INTERURBAN ADD IN SW 1/4 OF NW 1/4 OF SEC 24-23-04 --- AS PER CITY OF TUKWILA BDRY LINE ADJ NO 90-2-BLA RECORDING NO 9008151101 RCM TWO-STORY OFFICE BUILDING WITH SURFACE PARKING LOT 1999 - PER JURISDICTIONAL RECORD V -B FULLY SPRINKLERED (NO CHANGES) 2 ±40,922 SF (NO CHANGES) PROJECT DIRECTORY TENANT: BUILDING REPRESENTATIVE: ARCHITECT: CONTRACTOR: TABOR 100 JOHN C. RADOVICH.DEVELOPMENT 2835 82ND AVENUE SE, SUITE S-1, MERCER ISLAND, WA 98040 PHONE: 206-267-2669 EMAIL: REBECCA@JCRDEVCO.COM CONTACT: REBECCA DAVIDSON NELSON WORLDWIDE 1200 5TH AVENUE, SUITE 1300, SEATTLE, WA 98101 PHONE: 206-408-8537 EMAIL: KMATHWEG@NELSONWW.com CONTACT: KATIE MATHWEG DP INCORPORATED GENERAL CONTRACTORS 19936 BALLINGER WAY NE, SEATTLE, WA 98155 PHONE: 206-361-2989 EMAIL: VASILY@DPINC.NET CONTACT: BILLY SHADRIN •_________ FIRST DEFENSE FIRE PROTECTION 10212 215171 AVE SE SNOHOMISH, TA 98290 P 880-794-9479 Olt imm- -'-- ' ot) \-7---oc'-v-b•FtL.- ,(J-', . t,up\ 0\% V . . DETAILS jam NO. 10W0. NO. . . . .. DATE (0 . 11 I (3 SCALE AS NOTED.rrfv-, \ . Lkt. 20 - 0 Z5 - O E. • 525 - 0 0 E' 4 TP ELEVATOR W0:=8) :64) 1`(P. -j 0 1 NON -ACCESSIBLE / N -VOID SPACE - NAS Without As Note• ❑ Per The se plans have beenr MBUSTIBLE omments In Red ttached Letter ---.re._— viewed bT e Tukwila Fir dards. Acceptance is subject to errors and ornis8ons which do not authorize violations of adopted standards and ordinances. The responsibility for the adeg9 cy of design rests totally with the designer. Additions, deletions or revisions eo these drawings after this data will void this acceptance and will require a ttal of revised drawings for.subsequent approval. rr Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date:3 3/f. HEAD LEGEND MAKE 1. • RELIABLE • RELIABLE THE COMPLETE LINE/ 170483 .5f/Sc_2-- SRINKLERLER PLAN "e 0 8 16 SCALE 1/8"=1'-0" 474/ -bvoc2D. 244P ,/2cA- nI- TYPE SSP SSP MODEL G-REC G XLO-ECOH FINISH CHR CHR Cai.es7e ,C /> /16-41. ESC ORIFICE THRD TEMP CHR 1/2 1/2 165° CHR ' .64 3/4 165° QTY 5 5 SCOPE OF WORK: SMITH FIRE SYSTEMS WILL MODIFY THE EXISTING FIRE SPRINKLER SYSTEM TO INCORPORATE THE REMEDY INTELLIGENT STAFFING TENANT IMPROVEMENT. SFS WILL ADD 1" DROPS FROM THE EXISTING OUTLETS TO BELOW THE SUSPENDED CEILING AND CUT IN NEW OUTLETS AS NEEDED. DESIGN CRITERIA: -PER NFPA #13-1996 AND WSRB ORDINARY HAZARD GROUP 1 - .15 GPM OVER 1500 SQ. FT. FITTER/LISTER NOTES: 1) ALL MATERIALS TO BE UL LISTED AND/OR FM APPROVED. 2) (N) = 2" X 1" PIPE STRAP. 3) (R) = RELOCATE EXISTING SPRINKLER HEAD. (E) = EXISTING SPRINKLER HEADS. ALL DROPS TO BE 1" X I'-3"c/c TYPICAL, UNO. EXISTING SPRINKLER PIPING IS SHOWN AS DASHED LINES. ILA FIRE DEPARTMLP L 4) Please call: 575-4407 and give this job 5) tO ( and exact address for shut- 6) dawn or restoration approval. ROOM SHEDULE RM ROOM CEILING CEILING # NAME HEIGHT TYPE 101 OFFICE 8'-0" ACT 102 VIEWING 8'-0" ACT 103 TESTING 8'-0" ACT 104 STORAGE 8'-0" ACT 105 OFFICE 8'-0" ACT 106 OFFICE 8'-0" ACT HANGER LEGEND: D - GRINNELL FIG. 92 TOP BEAM CLAMP, 3/8" ATR, 8" RETAINER STRAP, & RING. KEY PLAN NTS FILE SMITH FIRE SYSTEMS, INC. 1106 54th Ave. E. Tacoma, WA 98424 CONTR. REG. NO. SMITHFS1360T Ph: (206) 926-1880 Fax: (206) 926-2350 PROJECT REMEDY INT. STA 7100 FORT DENT WA TU KW I LA, WA. DESIGNER BARRY GOODING MTN- MAR 17 1999 3 - I4-99 1 OF 1 JOB NO. TI -III HYDRAULICALLY MOST DEMANDING AREA: SYS* 1 DENSITY: .15 GPM OVER 1500 SQUARE FEET SYSTEM DEMAND AT BOR: 528.17 QPM AT 48.85 PSI (INCLUDING 0 GPM FOR INSIDE HOSE STREAMS) HANGER LEGEND 2ND FLR. T.I. SPRINKLER PLAN 0 4 8 SCALE 1N'-1'-0' FITTER / LISTER NOTES 1. TYPICAL DROP TO BE 1(1-0) TOE. 2. TYPICAL HANGER TO BE IT' TYPE. 3. TYPICAL CEILING HEIGHT AT 8'-" AFF. SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND QUALITY CONTROL BY: DATE 2' TAPPED SOUARE WASHER WITH 3/8' X 54' (CTS) ATR GYM • • MANUFACTURER RELIABLE RELIABLE TYPE MODEL SSP Q REC 8SP GXLO•ECOH ewm•°, CHR CHR CHR CHR 1/2' .64' 1/2' 3)4' 166 165 19 10 AFF 808 BOD BOJ BOP DDT 018 FO 4.65 OFOW NAB LINO ABOVE RFORED ROOK RONDIJ OF 8E05 WO/ OF DECK 80110 4 OF JOIST WHOM OF RTRUN BOTTOM OF MSS CUT TO SUIT ROD OAOER POLE FACE OF WALL MILE FACE OF WALL NO AUTO. SHOWILY) ME89 NOTED OTIEAV8SE CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2•WAY EARTHQUAKE SWAY BRACE LEITER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE LEITER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO DATE BY REVISIONS REASON FOR REVISION APPROVED FOR FABRICATION AREA BY DATE CONTRACT WITH FOUSHEE & ASSOCIATES 3260 118TH AVENUE S.E. P.O. BOX 3767 BELLEVUE, WA 98009-3767 PROJECT MANAGER : MIKE FEY PHONE : (425) 748-1000 FAX : (425) 7483737 SUPERINTENDENT : SKIP STEINBACK PHONE: FAX : GENERAL NOTES 1. AU. COUPLINGS WITH (F) TO BE FLEXIBLE 2. ALL NEW PIPE TO BE AS FOLLOWS: STEEL PIPE ASTM A-795 OR BETTER 25'40• 25'41' 25'-0' 25'-0' `r END PREP TYPES ALLOWED mall? OF vane/ CAPACITY 84=Lo„L ..-� .--� 10.47 0.133 1.049 THREADED, CUT GROOVED, ROLL GROOVED, PLAIN END, POLISHED 1 I ( 1 1 I II ! I 1 ROLL GROOVED, POLISHED, PLAIN ENO (FOO BUTT WELDING) 1.817 0.097 1 1 Iz SUPER-FLO 2 172.448D. ROU. GROOVED POUSIED PLAIN ENO(FOR BUTT WELDING ) 2 ' 3UPER.FLO 0.074 2 ROLL GROOVED POLISHED PLAIN END WHDI FOR BUTT NO , ( ) 3.468 2' 21/2 O 21 1 2 4.734 0.303 3 r- 0.074 3.352 2' 6.626 0.458 4 11 0.074 4.352 ------'--------.._...._ 9.927 --------- -1"-------- 10 0.134 __._ 18-0 ___........___._. 17.300 _ ...__._-__......._..L 1' 0.134 8.357 9-0 23.030 O 1 1 14-0 I 1 14.01 1 to 1 1 I 1 I I � �N 1 I I I I I C I V 18 1 STAIR #12 I 1,1 1 . : I 9@AFF I �, ADJ EENT 1 LEASE.AREA_ I... .. ...-1 1 1 1 1 I 1 i Il I II 11 .-_..__._..._.._: I „-- I I I I I 1 L I 1 I 1 1 I 1_-- 1 I }l am tl� 12-8 0 --!- -I .I I I� II I NEW BAANCHUNE I 1 I I°R" 3 I I I I 2 I I� I 7 I 1- I -11 • I ®.___ _ �--�-- tF0 ---d 0-- •- - ------1....yo-0 - ----- -- ---- ------ s3 - � sa-- • i' y.o • -. -. •1 51 I , I I I l7 1 1 1 I I 2 $I1 �l °� I I 2' l 1 ---------0 • ..--- ,8-0 i • ("'© ,` 11i-0 ® �) -�, ' t 253 - 252 I i,o , I .�) 14-0 ® • 14-0 _ • 141 , I COMMON CORRIDOR I • ,`, 1 12091 L- L 1 q- - R -- Z-0 3s1 STOR IT P ICE OPY/MAIL CONF ENTRY] I ' i •4 Egg E� % 1203 1 j 1 pQ2J I -' 12C1 1 1 I NEW BRANCHUNE •- - _ I 1 ./ MEC. 2 GRV C OSS 2 2 !�� ! .---"-1 _ 2 °1 ) 1 83 11.9 •` I H • 7{ •I�1 1 LL • 7.3, ✓ NO 0-B 10-0 • 8 0I • 1 1 � 1 - 0 GC)1 © �Q� �' i 355 1 I 53 - 1 �Q• I I I I C i N 1 I L c+° IItItItIII���itltlttll�tlltll��e A IIS 2 2 2 �, 2 2 2 2 2 2 2 2 2 2 2 1 1 180 • ' 1tr0 1-0 ' 3-0 8{ ' 8-0 9-0' 1-0...__$-0 1-0 ' 3-0 ' 13.0 ' a-0 1 1 --------}---- ---- --� 286 - --'--- ---------- -- ------ O'-• I - -' ._. _..-------.....---- ------------ --------1_._...-- --- ® I'-"---------- ---- -----._--- ----I----------- ------1--- ------------ -----.j-.._.._--- ---..----- -----..._. ___ I ■ ©� ' -pBX II O 12071 I /� I 1 } ' ' 1 2ND FI;.R LOBBY I 1 I I I OP E F1 OFFICE] I 1 J 1 4 208 j q - - -1 - - - 1 -- - -IIIIIIIIIIIIIMI 1-- -y I 1 1 1 1 fi 1- � 1____ 1 --- ----I -- 1 1 I I I I A `• ^� I 1 1. ! 4f 1 I ! • 1 I - I 1 I O 1 2 I 1 2 I 2 2 1 2/ 2 1 ' 12 2 1 1 2 1 / 21 2 1 . I 18-0 I I I 16-0 I • .-i 1.0_ _ c -- 9G i 6-0 13431--,-0 1 3A 3-0, 13-0 /r 2-0 1 m 1 I I 1 I 1 I 1 I 1 I 1 1 I I 1 I I 1 I - _ - -I_ - - -1 1 J I I - _._.. _.... - I - 1-..... - -C- -- - __ _ -__ 1_ - - _- HYDRAULICALLY MOST DEMANDING AREA: SYS* 1 DENSITY: .15 GPM OVER 1500 SQUARE FEET SYSTEM DEMAND AT BOR: 528.17 QPM AT 48.85 PSI (INCLUDING 0 GPM FOR INSIDE HOSE STREAMS) HANGER LEGEND 2ND FLR. T.I. SPRINKLER PLAN 0 4 8 SCALE 1N'-1'-0' FITTER / LISTER NOTES 1. TYPICAL DROP TO BE 1(1-0) TOE. 2. TYPICAL HANGER TO BE IT' TYPE. 3. TYPICAL CEILING HEIGHT AT 8'-" AFF. SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND QUALITY CONTROL BY: DATE 2' TAPPED SOUARE WASHER WITH 3/8' X 54' (CTS) ATR GYM • • MANUFACTURER RELIABLE RELIABLE TYPE MODEL SSP Q REC 8SP GXLO•ECOH ewm•°, CHR CHR CHR CHR 1/2' .64' 1/2' 3)4' 166 165 19 10 AFF 808 BOD BOJ BOP DDT 018 FO 4.65 OFOW NAB LINO ABOVE RFORED ROOK RONDIJ OF 8E05 WO/ OF DECK 80110 4 OF JOIST WHOM OF RTRUN BOTTOM OF MSS CUT TO SUIT ROD OAOER POLE FACE OF WALL MILE FACE OF WALL NO AUTO. SHOWILY) ME89 NOTED OTIEAV8SE CENTERLINE OF PIPE TO REFERENCED STRUCTURE IN INCHES 2•WAY EARTHQUAKE SWAY BRACE LEITER INDICATES TYPE 4 -WAY EARTHQUAKE SWAY BRACE LEITER INDICATES TYPE HANGER LOCATION ELEVATION ABOVE REFERENCED POINT IN FEET AND INCHES HYDRAULIC CALCULATION NODE FLEXIBLE COUPLING RIGID COUPLING NO DATE BY REVISIONS REASON FOR REVISION APPROVED FOR FABRICATION AREA BY DATE CONTRACT WITH FOUSHEE & ASSOCIATES 3260 118TH AVENUE S.E. P.O. BOX 3767 BELLEVUE, WA 98009-3767 PROJECT MANAGER : MIKE FEY PHONE : (425) 748-1000 FAX : (425) 7483737 SUPERINTENDENT : SKIP STEINBACK PHONE: FAX : GENERAL NOTES 1. AU. COUPLINGS WITH (F) TO BE FLEXIBLE 2. ALL NEW PIPE TO BE AS FOLLOWS: STEEL PIPE ASTM A-795 OR BETTER PIPE BRE SCHEDULE WALL THICKNESS INTERNAL DIAMETER END PREP TYPES ALLOWED mall? OF vane/ CAPACITY 84=Lo„L 1 40 0.133 1.049 THREADED, CUT GROOVED, ROLL GROOVED, PLAIN END, POLISHED 2.053 0.044 1 1/4 SUPER-FLO 0.059 1.642 ROLL GROOVED, POLISHED, PLAIN ENO (FOO BUTT WELDING) 1.817 0.097 1 1 Iz SUPER-FLO 0.07452 172.448D. ROU. GROOVED POUSIED PLAIN ENO(FOR BUTT WELDING ) t 26 2 3UPER.FLO 0.074 2.227 ROLL GROOVED POLISHED PLAIN END WHDI FOR BUTT NO , ( ) 3.468 0.202 21/2 SUPER-FLO 0.074 2.727 ROLL GROOVED, PLAN ETD (FOR BUTT WELDING) 4.734 0.303 3 SUPER-FLO 0.074 3.352 ROLL GROOVED, PIAN END (FOR BUTT WELDING) . 6.626 0.458 4 SUPER -R.0 0.074 4.352 ROLL GROOVED, PLAIN END (FOR 8U1T WELDING) 9.927 0.773 5 10 0.134 6.295 ROLL GROOVED, PIAN END (FOR BUTT WELDING) 17.300 1.144 6 •• 0.134 8.357 ROLL GROOVED, PLAIN @n (FOR BUTT WELDING) 23.030 1.849 8 •• 0.188 8.249 ROLL GROOVED, PLAIN EFL (FOR BUTT WELDING) 40.080 2.78 •• WALL THICKNESS PER NFPA 0 13 SCOPE OF WORK SMITH FIRE SYSTEMS (SFS) WILL MODIFY THE EXISTING WET PIPE AUTOMATIC SPRINKLER FIRE PROTECTION SYSTEM TO'PROTECTTHE NEW TENANT IMPROVEMENTS. SFS WILL START WORK AT THE EXISTING OVERHEAD SPRINKLER PIPING. CLARIFICATIONS - ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED ATA MINIMUM OF 40° F BY OTHERS TO PREVENT FREEZING. - SFS ASSUMES THE STRUCTURE TO BE ADEQUATE TO SUPPORT THE SPRINKLER SYSTEM EXCLUSIONS - PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT • ELECTRICAL WIRING OF ANY KIND - CENTRAL STATION MONITORING EQUIPMENT, WIRING AND MONITORING SERVICES DESIGN CRITERIA ORDINARY HAZARD GROUP 1 PER NFPA 13 (1996 ED.) CE TE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city fandards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the :adequacy of design rests totally with the designer. Additions, deletions or revisions .) these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. 511-171:)1 Date: k By: TUKWILA FIRE DEPARTMENT; Please call: 575.4407 and give this job No. and exact address for sh t down or restoration approval,. MAY 1 Z 999 SMITH FIRE SYSTEMS, INC. TAOOMMA, th AVE 84 TACWA 9642424 CONTR. REG. N0. SMITHFS1380T Bus: (253) 926-1880 FAX: (263) 926-2360 HYUNDAI T.I. 7100 FORT DENT WAY TUKWILA, WASHINGTON DESIGNER L COLE DATE 5.11-99 SHEET 1 OF 1 JOB N0. T1-119 N.I.C. 203 204 E 8'-t' E /EXISiT E E 1- 2 MAX 5'-0" 5'-0" 4" STEEL :AR JOISTS E 202 4-6 EXIST iii////////.///////////////// 0-41. 1 ELEVATOR LOBBY 1 1 /2" E � 1 1-10 81-0" 1 -0 2-0 V/////////// 8'-Q' -0 200 OPEN - �x SECOND FLOOR PIPING PLAN REFLECTED CEILING SCALE: 1/4" =1'-0" 201 112" SSU 1" ARM -OVER (VARIES) 1" POL EXISTING 1" DROP EXISTING EC PEND. NEW EC PEND. DROP DETAIL TOP OF BAR JOIST RETAINER STRAP. AFCON MODEL 160 SCALE: N T S BRANCHLINE 1 MAIN BEAM CLAMP / C -CLAMP WITH SET SCREW. AFCON MODEL 100 3/8" ALL THREAD ROD. =MU PIPE SWIVEL RING. AFCON 300 HANGER DETAIL SCALE: N T S 3/8" HEX NUT, WASHER & FENDER WASHER ABOVE AND BELOW TOP CHORD. TOP CHORD OF STEEL JOIST. 3/8" ALL THREAD ROD. PIPE SWIVEL RING. HANGER DETAIL SCALE: N T S SCOPE OF WORK 1. ARCHER CONSTRUCTION TO RELOCATE AND ADD THE FIRE • SPRINKLERS FOR NEW TI WALLS AND CEILING CONFIGURATIOI 2. EXISTING SYSTEM IS ORDINARY HAZARD GROUP I. • FILE 3 TUKWILA FIRE DEPARTMENT. Please call: 575.4401 end give this job No. and exact address for shut• down or restoration approval. CCErTE Without Comments As Noted In Red 0 Per The Attached Letter EXISTING HEADS ARE EXTENDED COVERAGE (16x16) 256 SQ. FT. MAX A HEAD. 8'-0" MAX. OFF WALLS. 4. ALL AREAS ABOVE CEILING ARE PROTECTED BY EXISTING UPRIGHT SPRINKLERS. CLAIRIFICATIONS ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED AT A MINIMUM OF 40° F (BY OTHERS) IN ORDER TO PREVENT THE PIPE FROM FREEZING. EXCLUSIONS TAXES OF ANY TYPE. ELECTRICAL OF ANY TYPE. SPRINKLER HEADS CENTERED IN CEILING TILE ANY ADDITIONAL TENANT IMPROVEMENT WORK. STRUCTURAL VERIFICATION. ABATEMENT, PREPARATION FOR & PAINTING OF ANY TYPE. DESIGN CRITERIA THROUGHOUT: HAZARD: G PER NFPA #13 (1999 EDITION) AND CITY OF TUKWILA ORDINARY HAZARD GROUP NERAL NOTES 1. ANG ALL ARM -OVERS GREATER THAN 1'-0" PER NFPA 13, 1999ed. 6-2.3.4 ex. (100+ PSI) SEE HANGER DETAIL "D" ON SHEET FPI OF 1. 2. HEADS ARE NOT REQUIRED TO BE CENTERED IN CEILING TILE. 3.. ALL NEW PIPE TO BE 1" EDDYTHREAD. These plans have been reviewed by The Tukwila Fire4' Prevention Bureau for conformance with current city standards. Acceptance is st. bject to errors and • omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions o these drawings after this date will void this, acceptance. and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: // — �l "O c� By: 4:1'.-5-1 ( ADD NEW ECOH SPRINKLERS W/ NEW 1" TEE 1'-0" ABOVE CEILING (SEE DETAIL #1 ON FP1 OF 1), OR 1 x 1%. MECH T LEGEND MT= E0 P -O A 112'S EXISTiN3 SPRINKLER PIPE. NEW SPRINKLER PIPING. MECHANICAL TEE. EXISTING PENDENT HEAD TO REMAIN - EXTENDED COVERAGE 16 x 16. EXISTING PENDENT HEAD TO BE REMOVED. EXISTING 1" OUTLET LOOKING DOWN. EXISTING PENDENT TO BE RELOCATED - EXTENDED COVERAGE 16 x 16. (2 TOTAL) NEW CHROME PENDENT HEAD W/ REC'D ESC. RELIABLE MODEL GFR VELO-ECOH. (2 TOTAL) NEW CHROME PENDENT HEAD W/ REC'D ESC. RELIABLE MODEL F1. (2 TOTAL) AREA OF WORK KEY PLAN U/S FOR REFERENCE ONLY SCALE: N T S HANGERS ATTACHMENT NOTES REVISIONS ABBREVIATIONS SPRINKLER SYMBOLS A B C D E F G H J K L M N BEAM CLAMP W/ RETAINING STRAP SIDE BEAM BRACKET EYE SOCKET NUT & PLATE WASHER WEDGE ANCHOR CONCRETE INSERT - HDI -P SAMMY SIDE WINDER - GST 20 SAMMY SCREW - SWG 20 TRAPEZE CEILING FLANGE U -HOOK SHORT STRAP IA/AI I RRC(:I(I T DATE DESCRIPTION BY AFF BOB BOD BOJ BOP BOT CTS FO IFOW pFOW NAS UNO --11-- ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE FLEXIBLE COUPLING RIGID COUPLING SYM MAKE MODEL THREAD ORFICE TEMP FINISH ESCUT. QTY • R RELIABLE GFR-ECOH 3/4" 17/32" 155°F CHR RECD 2 • A RELIABLE GFR-ECOH 3/4" 17/32" 155°F CHR REC'D 2 •1/2" RELIABLE F1 1/2" 1/2" 155°F CHR REC'D 2 RONALD & ASSOCIATES FORT DENT III 7100 FORT DENT WAY TUKWILA, WA 98188 FIRST FLOOR SPRINKLER PLAN PERMIT NO: JOB NO: SO4-110 TOTAL 6 FIRE SPRINKLER DIVISION 7855 S 206TH STREET PHONE 253-872-7222 KENT, WA 98032 FAX 253-872-7277 CONTRACTOR: FOUSHEE AND ASSOCIATES PHONE: 425-746-1000 FAX: 425-746-3737 AUTHORITY: CITY OF TUKWILA DESIGNER: K. WILSON SCALE: ' AS NOTED DATE: DECEMBER 06, 2004 REVISED / / PLATTED / agPk..0,it 0 L. 3P.0 05V ----- 96/70/90 N0009 BMP -I'd. OZT-T.L\OZT-T.L\9ZT-II oy TOT-T.L\seTTa 4oC\Tmae,L\Punog lebnd yInos\sooQsds\:O -•- 25'-0" - 25'-0" -..1 II 25'-0" O EXISTING CORRIDOR ,,,,,,,,,,,, SPRINKLER LEGEND SYM • • MANUFACTURER RELIABLE RELIABLE SPRINKLER PLAN TYPE MODEL FINISH H7IS SSP G XLO-ECOH CHR SSP G-REC CHR ESCUTCHEON FINISH ORIFICE SIZE THREAD SIZE TEMP. RATING QUANTITY CHR 1/2" 1/2" 165° 13 CHR 1/2" 1/2" 165° 4 SCOPE OF WORK SMITH FIRE SYSTEMS (SFS) WILL MODIFY THE EXISTING SPRINKLER SYSTEM TO INCORPORATE THE CLINIQUE TENANT IMPROVEMENT. SFS WILL ADD BRANCHLINE 215A, ADD DROPS FROM EXISTING PIPING, AND CUT IN NEW OUTLETS FOR DROPS AS NEEDED. DESIGN CRITERIA LIGHT HAZARD: .10 GPM OVER 1500 SQ. FT. BUILDING SHELL DESIGNED TO ORDINARY HAZARD GROUP 1: .15 GPM OVER 1500 SQ. FT. PER NFPA 13 (1996 EDITION) FITTER/ LISTER NOTES 1. RUN ALL PIPE 9' - 3" AFF. 2. ALL DROPS 1 x 0' - 9" UNO. 3. ALL HANGERS TO BE TYPE D. 4. (7) "AS" = ADD W/ 2" x 1" STRAPS (STRAIGHT DOWN). 5. (6) "T" = ADD W/ 2" x 1" STRAPS AND ARM OVER. 6. (4) "N" = ADD FROM NEW BRANCHLINE. 7. (6) "P" = PLUG EXISTING OUTLET. 8. CEILING HEIGHT AT A.C.T. IS 8' - 6" UNO. 9. ALL THREAD RODS TO BE 40" C.T.S. HANGER LEGEND D - TOP BEAM CLAMP W/ RETAINER STRAP AREA OF WORK (SECOND FLOOR) KEY PLAN CC .. T Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire P evention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. AJditions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings forsubsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. D ate: ?/[/f f By: SMITH FIRE SYSTEMS, INC. r 1106 54th AVE EAST TACOMA, WA 98424 CONTR. REG. NO. SMITHFS1360T Bus: (253) 926-1880 FAX: (253) 926-2350 CLINIQUE TENANT IMPROVEMENT FORT DENT III 6860 FORT DENT WAY TUKWILA, WA DESIGNER B. COOK DATE 6/3/99 SHEET 1 OF JOB NO. Ti -120 F FUKWILA FIRE DEPARTMLN1 Please call: 575-4407 and give this job lJ and exact address for shut- down or restoration approval. 7/0 /j ii may. I FIIL IRIOEELTM gi JUN 0 4 1999